Loading...
HomeMy WebLinkAboutWinter aquatic investigations Sep 1983 to May 1984 Vol 1 draft 1985i <-U:5 tur 451 AN EVALUATION OF THE INCUBATION LIFE PHASE OF CHUM SALMON 1 IN THE MIDDLE SUSITNA RIVER I SUSITNA HYDRO AQUATIC STUDIES WINTER AQUATIC INVESTIGATIONS: SEPTEMBER, 1983 - MAY, 1984 1985 REPORT NO. 5 VOLUME 1 1 1 -ay- ALASKA DEPARTMENT OF FISH AND GAME ' SUSITNA HYDRO AQUATIC STUDIES 620 EAST TENTH AVENUE ANCHORAGE, ALASKA 99501 I I I I I GRAFT 2/11185 I PREFACE i This report is one of a series of reports prepared for the Alaska Power Authority (APA) by the Alaska Department of Fish and Game (ADF&G) to ' provide information to be used in evaluating the feasibility of the proposed Susitna Hydroelectric Project. The ADF&G Susitna Hydro Aquatic 1 Studies program was initiated in November 198C. The five year study program was divided into three study sections: Adult Anadromous Fish Studies (AA), Resident and Juvenile Anadromnus Studies (RJ) , and Aquatic ' Habitat and Instream Flow Studies (AH). Reports prepared by the ADF&G prior to 1983 on this subject are available from the APA. Beginning with the 1983 reports, all reports were sequentially numbered as part of the Alaska Department of Fish and Game Susitna Hydro Aquatic ' Studies Report Series. ' TITLES IN THE AOF3G REPORT SERIES Report Publication ' Number Title pate ! Adult Anadromous Fish Investigations: April 1984 ' May - October 1983 2 Resident and Juvenile Anadromous Fish July 1984 Investigations: May _ October 1983 3 Aquatic Habitat and Instream Flow Sept. 1984 Investigations: May - October 1983 4 Access and Transmission Corridor Aquatic Sept. 1984 Investigations: May - October 1983 5 Winter Aquatic Investigations: March 1985 September, 1983 - May, 1984 1 1 DRAFT 2/11/85 7 This report provides results of the 1983-198a winter studies conducted by the ADF&G to evaluate and compare existing chum salmon incubation conditions in selected slough, side channel, tributary, and mainstem habitats of the Susitna River between Talkeexna and Devil Canyon (River Miles 98-152). The types of data presented in this report include development and survival data for chum salmon embryos, surface and intragravel water quality data (pH, conductivity, temperature and dissolved oxygen), and substrate composition data. 1 I I I DRAFT/2/11/85 I I AN EVALUATION OF THE INCUBATION LIFE -PHASE OF CHUM SALMON I H L 1 I 1 1 I ' ABSTRACT IN THE MIDDLE SUsITNA RIVER REPORT NUMBER 5: VOLUME 1 WINTER AQUATIC INVESTIGATIONS: SEPTEMBER, 1983 - MAY, 1984 By Leonaird J. Vining, Jeffory S. Blakely, and Gi efan M. Freeman 1985 Alaska Department of Fish and Game Susitna Hydro Aquatic Studies 620 10th Avenue Anchorage, Alaska 99501 ' An evaluation of the survival and pattern of development of chum salmon embryos (to 50% hatch) was made between embryos incubated in artificial redds in slough, side channel, tributary and mainstem habitats. Eggs ' were obtained on site and artificially fertilized. After allowing them to water -harden, fifty embryos were placed in each Whitlock-Vibert Box ,WVB) and installed in the streambed. Intragravel temperature, dissolved oxygen, pH, conductivity and substrate composition were ' measured within each type and compared to the percent survival of embryos. A quantitative analysis of the effect of each variable on survival was hampered by the overwhelming mortality due to dewaterl-g ' and subsequent freezing of the substrate (and embryos). This effect wa�; greatest in side channels and least in sloughs, and was observed to Le directly related to the location and strength of upwelling. Mouth areas in slough, side channel, and tributary habitats also undergo freezing 1 I ORAFTI2111/85 because the stage in the rnainstem decreases significantly after fish spawn, resu,ting in dewatering of mouth areas. Although there were no definable relationships between percent survival and any other variables, the lower limit of survival was apparent for percent of fine substrate (C 0.08 in) and for dissolved oxygen. The percent survival of embryos decreased to zero when the percent of fines (C 0.08 in) was greater than 18%. Similarly, percent survival of embryos was zero at dissolved oxygen levels below 3.0 mg/l. Intragravel water temperature directly controls the pattern of develop- ment of embryos. There was a high degree of variability in the i ntra- gravel water temperatures within and between Fabitat types. In general, sloughs exhibit relatively warmer (approximately 2.0-4.0°C) and stable Intragravel temperatures because of the stabilizing influence of. 1n contrast, Intragravel water temperatures in tributary and mains, -'fm habitats reflect the large seasonal variations in surface water temperatures. Temperature condiO gns in side channels d❑ not conform to a "typical" pattern. It is hypW.esired that the earlier arrival of chum salmon spawning in tributaries, compared to sloughs, is related to the differences in their thermal regimes. ii I I I fl I I TABLE OF CONTENTS Pace VOLU14E 1 ABSTRACT...................................................... i TABLE OF CONTENTS ............................................. LIST OF FIGURES ............................................... vi LIST OF APPENDIX FIGURES ...................................... xiii LIST OF TABLES ................................................ xvii LIST OF APPENDIX TABLES........... ...... xviii LIST OF PLATES ................................................ xix 1.0 IIITR ucTION............................................. I 1.1 Background...... .... o—o .............................. . ' 1.2 Objectives ............................................. 7 2.0 METHODS ................................................... 8 2.1 Selection of Study Sites ............................... 8 2.2 Procedures for Evaluating Physical and Chemical Variables .............................................. 12 2.2.1 Intragravel Standpipes ............................. 12 2.2.2 Physical Variables... .............................. 17 2.2.2.1 dater Temperature .............................. 17 2.2.2.2 Substrate Composition .......................... 17 2.2.2.2.1 McNeil Sampler.... .... o ... --.— ........... 18 2.2.2.2.2 Whitlock-Vibert Box Sampler.... . .... 20 2.2.2.2.3 Additional Substrate Evaluation�Methods.... 22 2.2.2.3 hater Depth and Velocity....... .... ........ 23 2.2.2.4 Turbidity ...................................... 23 2.2.3 Chemical Variables. ............... o ......... o—oo. 24 2.2.3.1 Dissolved Oxygen ............................... 24 2.2.3.2 PH ....... ................................... 24 2.2.3.3 Conductivity ................................... 25 I iii CRC TABLE OF CONTENTS (Continued) Page 2.3 Biological Variables ................................... 25 2.3.1 Salmon Incubation .................................. 25 2.3.1.1 Procedures to Install and Remove Whitlock- Vibert Boxes.. .... ............... 25 2.3.1.2 Artificial Fertilization Procedure ............. 25 2.3.1.3 Installation of Whitlock-Vibert Boxes.......... 28 2.3.1.4 Removal of Whitlock-Vibert Boxes ............... 29 2.3.2 Flatwerms.......................................... 32 2.3.3 Analysis of Development and Survival of Embryos.... 32 2.3.3.1 Embryonic Development .......................... 32 2.3.3.2 Embryonic Survival. ....................... 33 2.3.3.3 Embryo Survival Control ........................ 38 3.0 RESULTS .................................................. 39 3.1 Comparison of Physical and Chemical Characteristics of Study Sites and Habitat Types ....................... 41 3.1.1 Physical Characteristics ........................... 41 3.1.1.1 Water Temperature .............................. 41 3.1.1.1.1 Instantaneous Intragravel dater Temperatures..� ......... .......... 41 3.1.1.1.2 Comparison ofInstantaneousSurface and Intragravel Water Temperatures ............. 44 3.1.1.1.3 Continuous Intragravel Water Temperatures.. 49 3.1.1.2 Substrate Composition... ....................... 56 3.1.1.2.1 Comparison of McNeil and Whitlock-Vibert Sox Samplers.... � .... .. ......... 59 3.1.1.2.2 Substrate Composition atStudy Sites....... 59 3.1.2 Chemical Characteristics ........................... 71 3.1.2.1 Dissolved Oxygen ............................... 71 3.1.2.2 pH. .................................... 76 3.1.2.3 Conductivity ................................... 84 3.2 Comparison of Embryo Survival at Study Sites and Habitat Types .......................................... 84 3.3 Effects of Physical, Chemical and Biological Habitat Variables on Embryo Survival at Study Sites and Habitats ............................................... 94 iv 1 1 TABLE OF CONTENTS (Continued) DRAFr ' Page 3.3.1 Physical Variables................ 94 ' 3.3.2 Chemical Variables ................................. 98 3.3.3 Biological Variables ............................... 104 ' 3.3.3.1 Development of Chun Salmon Embryos ............. 104 3.3.3.2 Flatworms ...................................... 105 ' 4.0 DISCUSSION ............................................... 107 4.1 Physical, Chemical, and Biological Variables Associated with Chun Salmon Incubation Habitats........ 107 ' 4.1.1 Upwellim3.......................................... 107 4.1.2 Dewatering and Freezing ............................ 109 4.1.3 Substrate ................................. 113 ' 4.1.4 Water Temperature.......... .................... 117 4.1.5 Dissolved Oxygen ................................... 123 4.1.6 pH......................................0.......... 129 ' 4.1.7 Conductivity .......................... 131 4.1.8 Turbidity .......................................... 132 4.1.9 Flatworms ...................... :................... 132 4.2 Conclusions/Recoomdations ............................ 134 4.2.1 Conclusions .................... 134 4.2.2 Recommendations....................... ........... 138 5.0 CON'iRIBUTORS............................................. 140 ' 6.0 ACKNOWLEDGEMENTS ......................................... 141 7.0 LITERATURE CITED ......................................... 142 VOLUME 2 8.0 APPENDICES Appendix A. winter Temperature Data ...................... i Appendix B. Study Site Flaps .............................. 8-1 Appendix C. Hater [duality Data ........................... C-1 Appendix 0. Substrate Data ............................... D-1 Appendix E. Additional Habitat Data ...................... E-1 Appendix F. Embryo Development and Survival Data......... F-1 DRAFT 2/ 11; 85 LIST OF FIGURES Figure Page 1. Map of the Susi4ma River Basin, with deline- ations of the bas,n drainage area and the middle reach of river .................................. 2 2. Generalized life cycle of a chum salmon indigenous to the middle Susitna River, Alaska......... 4 3. Locations of study sites within the middle reach of the Susitna River (RM 98-152)................. 9 4. Diagram of a polyvinyl chloride (PVC) standpipe i used to evaluate intragravel water conditions in streambeds of salmon spawning habitats in the middle Susitna River, Alaska ....................... 14 5. A modified McNeil substrate sampler used to evaluate substrate conditions of salmon spawning habitats in the middle Susitna River, Alaska. Sampler not drawn to scale .................... 19 6. Summary of methods used to evaluate substrate conditions obtained with a modified McNeil substrate sampler ...................................... 21 7. Flow diagram depicting the sequence of events which occurred during the artificial fertili- zation of salmon eggs and the subsequent installation of artificial incubation chambers (Whitlock - Vibert Boxes) in the streambed............. 27 8. Summary, by habitat type, of the intragravel water temperature data (°C) periodically measured within standpipes during the 1983-84 winter period in the middle Susitna River, Alaska................................................. 42 9. Summary, by study site, of the intragravel water temperature data (°C) periodically measured within standpipes during the 1983-84 winter period in the middle Susitna River, Alaska................................................. 43 vi DRAFT 2/11/85 LIST OF FIGURES (Continued' i i Figure P- A2e 10. Relationship between intragravel and surface i f water temperatures (*C) measured at standpipes within slough habitat of the middle Susitna River, Alaska......... ................................. 45 11. Relationship between intragravel and surface water temperatures (°C) measured at standpipes within side channel habitat of the middle ` 4 Susitna River, Alaska .................................. 46 12. Relationship between intragravel and surface water temperatures (OC) measured at standpipes within tributary habitat of the middle Susitna River, Alaska .......................................... 47 13. Relationship between intragravel and surface water temperatures (°C) measured at standpipes within slough, side channel, and tributary ' habitats of the middle Susitna River, Alaska........... 48 14. Mean daily intragravel water temperatures (°C) recorded during the 1983-84 winter period at Slough 10 (RM 133.8). middle Susitna River, Alaska................................................. 5O 15. Mean daily intragravel water temperatures (°C) recorded during the 1983-84 winter period at Slough (RM middle Susitna.- River. '11 . .135.3), Alaska. . ...'... 51 16. dean daily intragravel water temperatures (°C) recorded during the 1983-84 winter period at ' Slough 21 (141.8), middle Susitna River, Alaska........ 52 17. Akan daily intragravel water temperatures ('C) recorded during the 1983-84 winter period at Side Channel 10 (RM 133.8), middle Susitna River, Alaska .......................................... 53 18. Mean daily intragravel water temperatures (*C) recorded during the 1983-84 winter period at Ur)per Side Channel 11...(RM..136.1)...middle Susitna River, Alaska .. ..' .. 54 19. Mean daily intragravel water temperatures (°C) recorded during the 1983-84 winter period at Side Channel 21 (RM 141.0), middle Susitna River, Alaska .......................................... 55 vii DRAFT 2/11/85 LIST 0r FIGURES (Continued) Figure Pie 2C. Mean daily intragravel water temperatures (°C) recorded during the 19834.4 winter period at Fuurth of July Creek (RM 131.1), middle Susitna River, Alaska ................. ........................ 57 21. Mean daily intragravel water temperatures (°C) recorded during the 1983-84 minter period at Mainstem (RM 136.1) middle Susitna River, Alaska............................. .................. 58 22. Comparison of the dry weights (g) of fine substrate ([ 0.08 in. diameter) obtained from paired samples collected with McNeil and Whitlock-Vibert Box samplers ........................... 60 23. Comparison of percent dry weights of fine Substrate ([ 0.08 in. diameter) obtained from paired samples collected with McNeil and Whitlock-Vibert Box samplers ........................... 61 24. Percent size composition of McNeil substrate samples collected at study sites in the middle Susitna River, Alaska .................................. 62 25. Percent size composition of McNeil samples collected in various habitat types in the middle Susitna River, Alaska ........................... 63 26. Percent size composition of mine substrate (c 0.08 in. diameter) in McNeil samples col- lected at study sites in the middle Susitna River, Alaska .......................................... 65 27. Percent site composition of fine substrate ([ 0.08 in. diameter) of McNeil samples col- lected in various habitat types in the middle Susitna River, Alaska .................................. 66 28. Percent size composition of McNeil substrate samples collected at chum salmon redds during May 1984, in the middle Susitna River, Alaska.......... 67 29. Percent size composition of McNeil substrate samples collected at chum salmon redds during May 1984, in various habitats of the middle Susitna River, Alaska .................................. 68 viii DRAFT 2/11/85 i 1 1 1 i I LIST 4F FIGURES (Continued) Figure Page 3D. Percent size composition of fine substrate ([ 0.08 in. diameter) in McNeil samples col- lected at chum salmon redds during May 1984 in study sites of middle Susitna River, Alaska............ fig 31. Relationship between intragravel and surface water dissolved oxygen concentrations (mg/1) measured at standpipes within slough habitat of the middle Susitna River, Alaska ....................... 72 32. Relationship between intragravel and surface water dissolved oxygen concentrations (my/1) measured at standpipes within side channel habitat of the middle Susitna River, Alaska............ 73 33. Relationship between intragravel and surface water dissolved oxygen concentrations (mg/1) measured at standpipes within tributary habitat of the middle Susitna River, Alaska .................... 74 34. Relationship between intragravel and surface water dissolved oxygen concentrations (mg/1) measured at standpipes within slough, side channel, and tributary habitats of the middle Susitna River, Alaska .................................. 75 35. Summary, by study site, of the intragravel dissolved oxygen data (mgll) periodically measured within standpipes during the 1983-84 winter period in the middle Susitna River, Alaska................................................. 77 36. Summary, by habitat type, of the intragravel dissolved oxygen data (mgll) periodic -ally measured within standpipes during the 1933-84 winter period in the middle Susitna P-iver, Alaska................................................. 78 37. Relationship between intragravel and sUr`ace water pH levels ;ensured within slough habitat of the middle Susitna River, Alaska .................... 79 1 ix DRAFT 2 1.1I85 �'.ST OF FIGURES {Continued) Figure L"age 38. Relationship between intragravel and surface water pH levels measured within side channel habitat of the middle Susitna River, Alaska............ 80 39. Relationship between intragravel and surface water pH levels measured within slough and side channel habitats of the middle Susitna River, Alaska ................................................. 81 40. Summary, by study site, of the intragravel pH data periodically measured within standpipes during the 1983-84 winter period in the middle Susitna River, Alaska .................................. 8-2 41. Summary, by habitat type, of the intragravel pH data periodically measured within standpipes during the 1983-84 winter period In the middle Susitna River, Alaska. ................................. 83 42. Relationship between intra ravel and surface water conductivity levels ?umhoslcm) measured within slough habitat of the middle Susitna River, Alaska .......................................... 85 43. Relationship between intra ravel and surface water conductivity levels ?umhoslcm) measured within side channel habitat of the middle Susitna River, Alaska.. ................................ 86 44. Relationship betvfeen intra ravel and surface water conductivity levels �umhoslcm] measured within tributary habitat of the middle Susitna River, Alaska .......................................... 87 45, Relationship between intragravel and surface water conductivity levels �umhoslcm) measured within slough, side channel, and tributary habitats of the middle Susitna River, Alaska........... 68 45. Summary, by study site, of the intragravel conductivity data (umnoslcm) periodically measured within standpipes during the 1983-84 winter period in the middle Susitna River, Alaska................................................. 89 x I ORAFf 2/11/85 1 1 1 1 1 1 1 1 1 1 1 [I 7 J 1 1 1 1 LIST OF FIGURES (Continued) Figure Page 47. Summary, by habitat t pe, of the intragravel conductivity data (umhoslcm) periodically measured within standpipes during the 1983-84 winter period in the middle Susitna River, Alaska................................................. 90 48. Comparison of survival (%) of salmon embryos removed from artificial redds in study sites in the middle Susitna River, Alaska ....................... 91 49. Comparison of survival (%) of salmon embryos removed from artificial redds in various habitat types in the middle Susitna River, Alaska................................................. 93 50. Comparison within each habitat type of the percent survival of embryos when all samples are considered to the percent survival of embryos when all frozen samples are removed from consideration: middle Susitna River, Alaska................................................. 95 51. Comparison within each study site of the percent survival of embryos when all samples are considered to the percent survival of embryos when all frozen samples are removed from consideration: middle Susitna River, Alaska................................................. 96 52. Relationship between survival of salmon embryos W and the percent of fine substrate (< 0.08 in. diameter) within Whitlock-Vibert Boxes removed from artificial redds within selected habitats of the middle Susitna River, Alaska........... 99 53. Relationship between survival of salmon embryos W and intragravel water temperatures deter- mined at artificial redds within selected habitats of the middle Susitna River, Alaska........... 100 54. Relationship between survival of salmon embryos and concentration of intragravel dissolved oxygen (mg11) measured at artificial redds within selected habitats of the middle Susitna River, Alaska ..........................,............,.. 101 1 xi DRAFT 2,' 11/85 LIST OF FIGURES (Continued) Figure Page 55. Relationship between survival of salmon embryos and intragravel pH level measured at artificial redds within selected habitats of the middle Susitna River, Alaska .................................. 102 56. Relationship between survival of salmon embryos and intragravel conductivity level (umhoslcm) measured at artificial redds within selected habitats of the middle Susitna River, Alaska........... 103 i xii DRAFT 2/11/85 LIST OF APPENDIX FIGURES ' APPENDIX B 1 Figure Page 8-1. Study site location at Mainstem LRX 9 (RM 103.2) ............................................... B-3 ' 8-2. Study site location at Deadhorse Creek (RM 120.9) .........................0....................... B-4 9-3. Study site location at Slough 8A (RM 125.9) and Mainstem LRX 29 (RM 126.1)............................. 9-5 B-4. Study site location a Slough 9 (RM 128.3).............. 8-6 B-5. Study site location at fourth of July Creek (RM ' 131.1) ................................................. s-7 B-6. Study site location at Slough 9A (RM 133.6)............ B-8 B-7. Study site location at Slough 10 and Side Channel 10 (RM 133.8).................................. B-9 B-8. Study site at Slough 11 (RM 135.3), Upper Sian ' Channel 11 (RM 136.1) and Mainstm ON 136.1].......... B-10 1 B-9. Study site location at Mainstem (RM 136.8)............. 5-11 B-10. Study site location at Indian River (RM 138.6)......... B-12 ' B-11. Study site location at Slough 17 (RM 138.9) and Mainstem sites (RM 138.7 and RM 138.9) ................. B-13 B-12. Study site location at Side Channel 21 (RM 141.0), Slough 21 and Mainstem LRX 57 (RM 142.2) ................................................. B-14 1 ' xiii DRAFT 2/11/85 APPENDIX C Fire Page C-1. Summary, by study site, of the surface water temperature data {°C) periodically measured at standpipe locations during the 1983-84 winter Period in the middle Susitna River, Alaska............. C_i8 C-2. Summary, by hob1 tat type, of the surface water temperature dat (°C) periodically measured at standpipe locations during the 1983-84 winter period in the middle Susitna River, Alaska ............. C-19 Summary, by study site dissolved oxygen data measured at standpipe 1983-84 winter period River, Alaska........... of the surface water (mg11} periodically locations during the in the middle Susitna ............................... C-20 C-4. Summary, by habitat type, of the surface water dissolved oxygen data (mg11) periodically measured at standpipe locations during the 1983-84 winter period in the middle Susitna Rfver, Alaska .......................................... C-21 C-5. Summary, by study site, of the surface water dissolved oxygen data (% saturation) periodi- cally measured at standpipe locations during the 1983-84 winter period in the middle Susitna River, Alaska .......................................... C-22 C-G. Summary, by habitat type, of the surface water dissolved oxygen data (% saturation) periodi- cally measured at standpipe locations during the 1983-84 winter period in the middle Susitna River, Alaska .......................................... C-23 C-7, Summary, by study site, of the surface water pH data periodically measured at standpipe locations during the 1983-84 winter period in the middle Susitna River, Alaska ....................... C-24 C-8. Summary, by habitat type, of the surface water PH data periodically measured at standpipe locations during the 1983-84 winter period in the middle Susitna River, Alaska ....................... C-25 xiv DRAFT 2/ 11/85 APPENDIX C (ContinueO Figure page C-9. Summary, by study site, of the surface water conductivity data (umhoslcm) periodically measured at standpipe locations during the 1983-84 winter pet•; o,' in the mi ddl a Susitna River, Alaska .......................................... C-26 C-10. Summary, by habitat type, of the surface water conductivity data (umhoslcm) periodically measured at standpipe locations during the 1983-84 winter period in the middle Susitna River, Alaska................... ....................... C-27 C-11.. Relationship between percent saturation of intragravel and surface water dissolved oxygen measured within slough habitat of the middle Susitna River, Alaska.. ... ............................ C-28 C-12. Relationship between percent saturation of intragravel and surface water dissolved oxygen measured within side chanel habitat of the middle Susitna River, Alaska ........................... C-29 C-13. Relationship between percent saturation of intragravel and surface water dissolved oxygen I measured withw tributary habitat of the middle Susitna River, Alaska .................................. C-30 C-14. Relationship between percent saturation of intragravel and surface water dissolved oxygen measured within slough, side channel, and tributary habitats of the middle Susitna River, Alaska... .............................................. C-31 C-15. Summary, by study site, of the intragravel dissolved oxygen (% saturation) data periodi- cally measured within standpipes during the 1983-84 winter oeriod in the middle Susitna River, Alaska .......................................... C-32 C-16. Summary, by habitat type, of the intragravel dissolved oxygen (x saturation) data periodi- cally measured within standpipes during the 1983-84 winter period in the middle Susitna River, Alaska .......................................... C-33 1 I ry DRAFT 2/11/85 APPENDIX 0 Fi gure Page D-1. Comparison of dry weights (g) of fine substrate (0.08-0.02 in. diameter) obtained from paired samples collected with McNeil and Whitlock- Vibert Sox samplers .................................... D-5 0-2. Comparison of dry weights (g) of fine substrate (0.02-0.002 in. diameter) obtained from paired samples collected with McNeil and Whitlock- Vibert Box samplers .................................... 0-6 D-3. Comparison of dry weights (g) of fine substrate ( 0.002 in. diameter) obtained from paired samples collected with McNeil and Whitlock- Vibert Box samplers .................................... D-7 C-4. Percent composition, by size class, of Whitlock- Vibert Box samples collected at study sizes in the middle Susitna River, Alaska ....................... 0-8 D-5. Percent composition, by size class, of fine substrate (< 0.08 in. diameter) in Whitlock- Vibert Box samples collected at study sites in the middle Susitna River, Alaska ....................... D-9 0-6. Percent composition, by size class, of Whitlock- Vibert Box samples collected in various habitat types in the middle Susitna River, Alaska .............. 0-10 D-7. Percent composition, by size class, of fine substrate (C 0.08 in. diameter) in Whitlock- Vibert Box samples collected in various habitat types in the middle Susitna River, Alaska .............. D-11 xvi GRAFT 2/11/85 1 LIST :7 TABLES 1 Table Page 1. Reference list of study sites providing rela- tive site priority, river mile location and A. of data collected at each site .................... io 2. Stages of embryonic development for chum salmon identified for use in this study. Stages correspond to information reported for sockeye salmon by Nelsen(1980)................................ 34 3. Condition of de&d embryos at time of removal from substrate.................. ....................... 106 4. Documented effects of sediment and substrate size on salmonids, based on a review of selected literature .................................... 114 5. Observed temperature ranges for embryo/ a ievin life -phases of Pacific salmon [table derived i from AEIDC(1984)].................................... 119 6. Documented effects of low dissolved oxygen (04) levels on incubating salmonids, based on a review of selected literature .......................... 126 1 xvii DRAFT 2/11185 LIST OF APPENDIX TABLES APPENDIX B Table Page B-1. List of study sites used to evaluate the incubation life -phase of chum salmon in the middle Susitna River ................................... B-2 APPENDIX C C-1. Surface water quality data collected From August 1983 to May 1984, Susitna River, Alaska......... C-2 C-2. Intragravel and surface water quality data collected at standpipes from Septemher to December 1983, Susitna River, Alaska ................... C-7 APPENDIX D D-1. Substrate composition of samples collected with a modified McNeil substrate sampler in spring 1984, Susitna River, Alaska ............................ D-2 0-2. Substrate composition inside Whitlock-Vibert Boxes placed in, and retrieved from artificial redds, August 1983 to May 1984, Susitna River, Alaska................................................. D-3 APPENDIX E E-1. Substrate classification code used previously to assess substrate conditions in chum and sockeye salmon spawning habitats (Vincent -Lang et al. 1984) ........................................... E-1 E-2. Criteria used to assign a rank for the relative degree of embeddedness of substrate .................... E-2 E-3. Physical data collected at primary and secon- dary sites in the middle Susitna River, Alaska......... E-3 APPENDIX F F-1. Stages of development of live chum salmon embryos and alevins removed from middle Susitna Piver habitats, Alaska ................................. F-2 r-2. Percent survival of hatched and unhatched embryos recovered from Whitlock-Vibert Boxes placed in selected habitats of the middle Susitna River, Alaska .................................. F-8 1 1 1 1 1 1 1 1 DRAFT 2/11/85 LIST OF PLATES Plate 1. Method for installing polyvinyl chloride standpipes in the streambed using a sledge- hammer and driving rod ................................ 2. Ice plug removed from a standpipe in Fourth of JulyCreek ............................................. 3. Whitlock-Vibert Box compacted with accumulated siltand sand .......................................... 4. whiticrk-Yibert Boxes each containing sorted gravels and 54 chum salmon embryos, wrapped with a nylon cord. The nylon cords were later used to remove boxes from the substrate ................ S. various stages of embryonic development of chum salmon from fertilization to complete yolk -sac absorption ............................................. 6. Chum salmon embryo late in the cleavage stage.......:.. 1. Chum salmon embryo at late gastrulation ................ 8. Head (A) and body (B) of a chum salmon embryo at late organogenesis.................................. r Page is 16 30 31 37 1 DRAFT 2/11/85 1.0 INTRODUCTION 1 1.1 Background The primary purpose of this report is to compare development and survival of incubating chum salmon (Oncorhynchus keta) embryos within selected slough, side channel, tributary, and mainstem habitats of the middle reach of the Susitna River between Talkeetna and Devil Canyon (RM ' 98-1524; Figure 1). The report is based on the results of field studies Iconducted during the 1983-1984 ice -covered season (October - May). The middle reach of the Susitnz River was selected for study because the most obvious changes in ex'stlny physical characteristics of fish habitats are expected to occur within this reach (Acres 1982). Within this rnacr, of river; slough and side channel habitats were selected as the primary focus of Study because they (primarily sloughs) are extensively used by churn salmon for spawning and are likely to be directly influenced by project construction and ❑peraticn. Chum salmon ' were selected as the target species for study for two reasons. First, ' they are the numerically dominant species of salmon which utilize slough and side channel habitats for spawning and incubation in this reach of ' the Susitna River. Secondly, they are considered a good indicator species of expected chances which may affect sockeye salmon, the other ' salmon species of significance which also utilize these habitats for spawning and incubation. I GRAFT ❑ L L.. I GRAFT 2/11/85 There are four basic life -phases in the life cycle of chum salmon: ' passage, spawning, incubation, and rearing. The freshwater period of the life cycle includes all four life -phases, whereas the saltwater period includes only portions of the rearing and passage life phases. ' In general, chum salmon spend approximately 24% of their total life in freshwater and approximately 80% in saltwater (Figure 2). 7 I! In the middle reach of the 5usitna River system, upstream passage of ' adult chum salmon generally peaks during the last two weeks of August and the first two weeks of September (ADF&G 1983b: Appendix 8; Sautner et al. 1984). During this time, adult chum salmon migrate into a ' variety of aquatic habitat types (mainstem, slough, side channel, tributary, and tributary mouth) within this reach of the river to spawn, with major concentrations occurring in slough and tributary habitats. IOnce on the spawning grounds, female churn salmon select a suitable spawning site, often in areas of upwelling (AGF3G 1983b: Appendix 8; Vincent -Lang et al. 1984). The female normally excavates a depression ' in the streambed (i.e., redd) by turning on its .ide and rapidly flexing her body, creating strong water currents with the caudal fin. Once a ' depression is completed, the female and one or mw re attending males ' simultanecusiy release eggs and milt, respectively, into the depression. The eggs are then fertilized thus beginning a new generation of chum ' salmon. After fertilization, the female swims immediately upstream of the redd to begin excavation of another depression. In this way, the ' fertilized eggs deposited in the previously attended depression are 3 CRAFT CHUM SALMON LIFE CYCLE Cw OCEANIC REARING gyp* rn TO M ATU FEAT t O N a INCUBATION JULaY of Yid t (OCT - APR) 2 ul — JULY of YR 4-6 n7cry 1� ���•N 4y �i L Figure Z. Generalized life cycle of a chum salmon indigenous to the riddle Susitna River, VaSka. IDRAFT 2/11/85 covered with substrate materials that are excavated from the new de- ' pression. This process is successively repeated until the female has released all her eggs. After spawning, both sexes usually die within a ' few days (Morrow 1980). The fertilized eggs (embryos) remain in the substrate and incubate for several months. The length of this period is highly variable depending upon environmental conditions, particularly water temperature. ' Generally, this period of time from fertilization of the egg until ' active feeding by fry, is referred to as the incubation period or life - phase (F4cNeil and Bailey I975). While in the gravel, the embryos undergo a developmental process which ' can be divided into three phases: cleavage, gastrulation, and organo- genesis (Velsen 1980). During cleavage, the embryo undergoes a peric❑ of prolific cell division and ends as a flattened multicelluiar disc called a blastodisc. During gastrulation, the cells formed during cleavage develop into recognizable tissues which form the basic struc- ture of the embryo. This phase ends when the yolk becomes completely enveloped by a thin sheet of cells, resulting in the closure of the blastopore (external opening in the main cavity of an embryo during gastrulation phase). During the organogenesis phase, fins and internal organs are formed and the circulatory system becomes developed. It is during this prase that embryos become "eyed". The organogenesis phase ends when the embryo hatches out of the protective egg shell. At this paint, embryos are called alevins or pre -emergent fry (or sac -fry). 5 DRAFT 2/ 11/85 Newly hatched alevins (post hatching) remain in the gravel until spring. During this time they are sustained by absorbing their large yolk sac. When yolk sac absorbtion is nearly complete, the alevins emerge from the gravel and begin to actively feed (their rearing Iife-phase). Upon emergence from the gravels, they are referred to as fry. After spending only 1-2 months rearing in freshwater the seaward migration and smoltification process begins (Figure 2). Once at sea, they grow rapidly, generally reaching adult size in three to five years. Upon reaching this stage, they return to freshwater, cease feeding, and migrate upstream to their place of origin to spawn and die, thus completing their life cycle. During much of the incubation period, chum salmon embryos remain within the streambed and are unable to move actively to other areas. This immobility results in a close dependence of the incubating salmon embryos to the multitude of environmental (i.e., physical, chemical, and biological) conditions in the immediate area. The close dependence of the incubating salmon embryos on local environmental conditions causes this life -phase to be particularly vulnerable to changes in physical, chemical, and biological conditions which may result from the con- struction and operation of the Susitna Hydroelectric Project. Environmental changes which are expected to impact incubating chum salmon in slough and side channels of the middle reach of the Susitna River as a result of the operation and construction of the proposed hydroelectric facility include decreased and stabilized flows during the 6 DRAFT 2/11/85 open water periods, increased flows in the winter (Acres 1982), and a ' marked change in seasonal water temperatures and ice processes (AEIOC ' 1984). In addition, seasonal reductions in upwelling and increases in the frequency of overtopping, wh;ch are anticipated in ' sloughs and side channels, could impact incubating salmon embryos (Woodward -Clyde 1984). Changes such as lower or higher intragravel ' water temperatures and changes in the concentration of dissolved gases during the incubation life -phase could have secondary effects on the development and/or survival rates of pre -emergent fry (Combs 1965; ' Baxter and Glaude 1980; Velsen 1980; Heming 1982), as well as affec+ing the emergence timing of fry (e.g., Koski 1966). I 1.2 Objectives ' Due to the importance of the incubation life -phase, a study was initiated during the fall of 1983 to address two objectives: 1 1) Compare selected physical and chemical conditions used rol chum salmon incubation in selected slough, side channel, 1 tributary, and mainstem habitats of the middle Susitna River; and, 2) Evaluate the influence of selected physical, chemical, and biological variables on the survival of chum salmon embryos placed in artificial redds in slough, side channel, tributary, and mainstem habitats of the O dOie Susitna River. `1 DRAFT 2; 11/85 2.0 METHODS 2.1 Selection of Study Sites A total of 16 sites were selected for study in slough, side channel, tributary, and mainstem habiLats within the middle reach of the Susitna River (Figure 3, Table 1, Appendix Figures B-1 to B-12). Based on the type and quantity of data collected, each study site was classified as either primary or secondary. In general, greater effort was expended for data collection purposes at primary study sites. Primary_ Sites Primary stuffy sites were selected to provide a comparison of the rate of development and percent survival of chum salmon embryos between slough and side channels. Information collected at primary study sites included water quality, substrate, continuous water temperature, and embryo survival and development data. Of the eight primary study sites selected seven were used to evaluate embryo survival (Sloughs 10, 11, and 21, Side Channels 10 and 21, Mainstem (RM 136.1), and Fourth of July Creek) and five were used to evaluate embryo development [Slough 11, Mainstem (RM 136.1), Fourth of July Creek, Side Channel 21, and Upper Side Channel 11]. 1 I The process used to select primary sites was influenced by a variety of interrelated factors. In general, these sites were selected according to the following prioritized criteria: 8 1 GRAFT i 1 1 1 1 1 1 1 'Jryr slGt14M 17�--� r "M$ nM INN 13111,T11 fNDiAM R!V[aI- AOLD MCK MhCO[ AOUG" 00. 1104E CilalwlRL tq ♦!fr M }j J000, Crrrlt 400 OF, AALY CREElK � `rA ! ■f G � OAM SIC ITC NMI 0 V-094 ! to scat o &UNCL it YALPISnIt (�. 134LA) GOLD C M9K STAMM SLOWN n, urrsR SIM CNAMML 4. MSAIMSTEM LAM 054 71 UOU" SA s.0U4M SLO-UO14 ■A ! SUSiTNA RIVER +! WINTER STUDY SITES f9a3-f9aa Talka�ff►a i►.r■.. s..�.! INN "-*I Figure 3. Locations of study sites within the middle reach of the Susitna River (R1M 98-152). 9 z � D � i T p K x x x K $L u� s 8 ❑ r i.>. ] x sr x x x K x 7 • w � a t a� rPi K K x x x ac x K x x K C� cg r C i 4 • +� a+ w w q a K K x x K x ac x c e 0 a sc a N K K x x ac x x x x 2[ x x K K x P • 7 380 ] 0 is w b r ]ti T A Y. T T T T N T S% 71, L L L L V 4 L L N L L L L t L Lqq L b • A • 4 • • 4 ] yPt L E ■ C C C C C C C C +0 p ,r .� w �. T r ❑ O 6 O p ❑ ❑ O V N r 4 a. L a L CL L a t a �. M. 4 L a V N pV U U NNo 0 N V U 7 C N tfP1 cR [Qri e� x Q. 0� m 1+1 Q 41 M tin 4 W A Q1 G+ •� � M M M � M M r r N H rn M M M n7 ra f � w GC i r+ C a P • N a • � a n r. pp A Q1 D Y ` U • n O � ^ N � w N � T S � Ot � R � V L 0 C q, C C C VDf i aP+ 7 O D D. O D y u7 L6 LA N 0 �n rn +11 N N c u7 • r 10 QRAF7 2/11i85 1} to be representative of a wide range of chum salmon spawning density (i.e., in high and low density areas); ' 2) to ensure that side slough, upland slough, side charnel. ' mainstem and tributary (including mouth) habitats were repre- sented; 1 1 3) to be representative of a wide range it the amount of upwelTing; 4) in areas differing in patterns of seasonal intragravel water temperatures (i.e. areas with and without upweTT- ing); 5) to be representative of a wide range in the relative amount of ' fine substrate in the spawning gravels; and, ' S) in locations that were previously used for the Instream Flow Group 4 Hydraulic Model (IFG-4) (Vincent -Lang et al. 1984). I Secondary Sites Secondary sites were selected to provide a more comprehensive data base for winter water quality conditions in selected habitats used for chum salmon incubation. As such, only a limited amount of water quality and continuous water temperature measurements were collected at secondary study sites. In .the selection of these secondary sites, priority was given to sites which were known to ne used as spawning sites and/or 11 DRAFT 2111/85 sites used as water quality stations during the previous winter (as reported in ADF&G 1983c). Secondary sites include Sloughs 8A, 9, 9A, and 17, three mainstem sites (RM 136.8, RM 138.7 and RM 138.9), and Indian River. 2.2 Procedures for Evaluating Physical and Chemical Variables Methods presented in the following section are a summary of those presented in the FY84 ADFAG Procedures Manual (ADF3G 1984). As such, they are only intended to provide sufficient detail to allow for a critical review of the analyses presented. Specific details are only provided in areas where methods used in the field differed slightly from those presented in ADFBG (1984). 2.2.1 Intragravel Standpipes The measurement of water quality variables (other than continuous intragravel water temperature data) in the intragravel environment required the use of polyvinyl chloride (PVC) standpipes installed into the streamed. Standpipes designed for this study contained 40 perfo- rations 0.3 mm (one eighth inch) in diameter, located within a 7.6 cm (3.0 inch) band at one end of the standpipe, when the standpipe was installed into the streambed, the perforations allowed intragravel water to pass through the standpipe allowing water quality measurements to be obtained. The adopted designs for constructing she driving red and standpipe were modified from Gangmark and Bakkala (1958) and McNeil 12 I DRAFT 2/11/85 (1962) and had the advantages of being relatively inexpensive and easy ' to install (Figure 4), 5tandpipss were driven in the substrate using a driving rod and sledge ' hammer (Plate 1). Each standpipe was pounded into the substrate to a depth of approximately 31 cm (14.5 inches) centering the perforations at ' a depth of approximately 25 cm (10 inches) into the substrate. This depth was selected because it is the average depth at which chum salmon ' place their eggs in some Alaskan and Eritish Columbian stream systems ' (Kogl 1965; Nerritt and Raymond 1982). After a standpipe was properly installed, a cork/weight assembly was placed inside each standpipe to aid in removal of ice plugs formed ' during freezing weather conditions. This assembly was suspended inside each standpipe from a nylon cord attached to the standpipe cap (Figure ' 4). Ice plugs were removed by gently heating a small metal heat shield ' attached to the exterior of the standpipe at the water surface. The metal shield was heated with a propane torch while exerting upward ' pressure on the pipe cap. After a few minutes of heating, the ice plug partially melted and allowed the cork/weight assembly with attached ice plug to be withdrawn (Plate 2), thereby allowing for intragravel water ' duality measurements to be obtained. 13 CRAFT AIR WATER SUBSTRATE RV-, CAP Prevents daflrss grid $pow from ■ntier snp pipe. W I k )IT Aids in refnorai of ice ptuq s and reduces surface arm at the air/ water interface. TEN INCHES: Estimated mean depth of churn and sockeye salmon embryos, M$FORATIQNS.' Allows inflow of intrag"rai rater 4 I. Total of 4e holes { 2.Facer ring {IZ Kai as 1 1464*4 scccoa I m 9o►t. EXTENSION; Allows far settling •� ';' `"`� if fine motersols are present Figure 4. Diagram of a polyvinyl chloride (PVC) standpipe used to evaTuate intragravel water conditions in streambeds of salmon spawning habitats in the middle Susitna River, Alaska, 14 i CRAFT i 1 1 1 1 1 1 • r i W N� Plate 1. Method for installing polyvinyl chloride standpipes in the streambed using a sledgehammer and driving rod. 15 r � f • ' r x . IDRAFT 2/11/85 1 2.2.2 Physical Variables 2.2.2.1 Water Temperature Instantaneous surface and intragravel water temperatures were measured at all primary and secondary study sites. A Yellow Springs Instrument {YSI} dissolved oxygen/temperature meter (Model 57) and a YSI conduc- tivity/temperature meter were the primary instruments used to obtain ' instantaneous water temperatures inside and outside the PVC standpipes at all water quality study sites. On each sampling day, each YSI meter was calibrated using a Hydrolab Model 4041 water quality meter as a ' standard. The Hydrolab meter was calibrated before and after field sampling trips following the procedures outlined in ADFAG (1984). Continuous water temperature data were collected at selected primary study sites using either Omnidata datapod recorders and associated ' thermister pro''bes (Model No. 2321) or Ryan (Model J90) thermographs. Specific methods pertaining to these instruments and their use are ' presented in Appendix A of this report. 1 2.2.2.2 Substrate Composition Two primary methods were used to assess substrate composition in this ' study: the McNeil sampler method and the Whitlockhibert Box sampler method. 17 GRAFT 2/ 11/85 2.2.2.2.1 McNeil Sampler Substrate samples were collected at selected study sites using a mod- ified McNeil substrate sampler (Figure 5). At each selected study site, the McNeil substrate sampler was pushed down into the substrate to an approximate depth of 20-25 cm (8-10 inches). Substrate materials were then removed with a small shovel and placed into plastic five gallon buckets. After the non -suspended portion of the substrate materials was removed from the sampler, the remaining water inside the sampler (containing the suspended sediments) was agitated to bring fines into suspension by swirling a hand inside the sampler (care was taken to avoid formation of a vortex). After thoroughly agitating the water column, a one liter aliquot of water was removed and stored for further processing. The non -suspended and suspended portions of each substrate sample were transported to a laboratory facility for size class determinations. At the laboratory, the non -suspended portion of the substrate samples were placed in an oven at a uniform temperature (110°C) until dry (approximately 24 hrs). Once dried, samples were sifted (while being continuously shaken) through a series ❑f sieves which included the following mesh sizes: 12.5, 7.6, 2.5, 0.2, 0.05, and 0.0052 cm (5.0, 0.0, 1.0, 0.08, 0.02, and 0.0025 in. respectively). Sieve size selection was based upon recommendations of PTatts et al. (1983) and those previously used by ADF&G personnel for visual assessment of substrate materials in spawning areas (Vincent -tang et al. 1984). After fV I GRAFT Figure 5. A modified McNeil substrate sampler used to evaluate substrate conditions of salmon spawning habitats in the middle 5usitna River, Alaska. Sampler not drawn to scale. 19 DRAFT 2/11/85 sifting through sieves, the dry weight of each size class of non - suspended sediment was measured to the nearest gram and percent of total sample was calculated. "he smallest sieve size (0.0062 cm; 0.0025 i n ) corresponds to the size at which particles no longer readily settle out of suspension in water. For this reason, the amount of suspended particles in each sample was determined by estimating the amount of suspended sediment in the one liter aliquot of water taken at the time of sampling. This amount was then used to extrapolate for the total amount of suspended sediment in the entire volume of water inside the McNeil sampler. This quantity was then added to the quantity of substrate which passed through the smallest sieve size to determine total weight for this sieve size. The procedure for determining the amount of non -suspended and suspended material in each substrate sample is suaiarized in Figure 6. 2.2.2.2.2 Whitlock-Vibert Box Sampler In previous studies Whitlock-Vibert Boxes (WVBs) have been used as incubation chambers to evaluate the effects of environmental variables on salmon embryo survival (e.g., Reiser and Wesche 1977; Reiser 1981; Reiser and white 1981a). In each of these studies, fine sediments from the surrounding streambed were found to have accumulated in the WVBs when they were reproved from the substrate. Based on this, and telephone conversations with D. Reiser (pers. comm.), it was determined that in 20 1 1 1 1 1 1 I 1 1 1 1 1 1 McNEIL SUBSTRATE SAMPLE NON- SUSPENDED PORTION SECHMENT REMOVED FROM SAMPI.ER VIA SMALL SHOVEL. TRANSPORT SAMPLE TO LAB- ORATORY; OVEN DRY AT I10'C FOR 24 h OR UNTIL DRY. WHILE CONTINUOUSLY SHAKING SAMPLE, SIEVE THROUGH VARIOUS NESTED SIEVES. DETERMINE DRY W T. It % C` F TOTAL SAMPLE FOR EACH 512E CLASS OF NON - SUSPENDED SED- IMENT. Figure 6. DETERMINE DRY WT. OF MATERIAL FASSING THROUGH SMALLEST SIEVE MO052 CM). GRAFT SUSPENDED PORTION I SEDIMENT REMAINING SUSPENDED IN wATER INSIDE SAMPLER - DETERMINE TOTAL VOLUME OF WATER INSIDE SAMPLER: REMOVE I LITER R TRANSPORT TO LAB- ORATORY. r �, r"I It I - ��+r� OVEN DRY SAMPLE AT 93•C FOR 48 h OR UNTIL DRY. WEIGH TO NEAREST GRAM. EXPAND RESULTS OF I LITER SUSSRIMIPLE FOR 'OTAL VOLUME WITHIN "cNEIL SAMPLER AT TIME OF SAMPLE REMOVAL. CALCULATE TOTAL DRY WT. & % OF TOTAL SAMPLE COMPRISED RY S;;SPENDE❑ SEDIMENT. Summary of methods used to evaIuatr substrate conditions obtained with a modified McNeil substrate sampler. 21 DRAFT 2/11/85 addition to using WV8s as experimental incubation chambers to evaluate embryo sur,,,ivPi (Sec. 2.2.4.1.1), they could also be used as a means to evaluate the amount of fine materials present in the surrounding substrate. The WVBs were initially filled with sifted gravels of a ;:nown size (1.3 - 2.5 cm; 0.5 - 1.0 in. diameter), buried in the streamed, and later removed after a three to fivo month period. Substrate materials were removed from each WVB, double bagged in plastic freezer bags, and transported to a laboratory facility where the sample was frozen until it could be analyzed. Each sample was analyzed in the same manner as the non -suspended sediment portion of the McNeil substrate samples with the suspended portion of substrate sample being taken as the sediment portion passing through the smallest substrate sieve. The dry weights of fine substrate particles less than 0.2 cm (0.08 in.) were compared to dry weights of this size class obtained with the McNeil substrate sampler to determine if the two sampling methods were providing com- parable data on the accumulation of fines. Additional Substrate Evaluation Methods Two secondary methods were used to evaluate substrate conditions during this study. These additional methods were employed to allow a comparison of substrate data collected at IFG-4 modeling sites with substrate data collected for the incubation study. One method consisted of a visual classification method previously used to assess substrate l conditions in chum and sockeye salmon spawning habitat [Vincent -Lang et q� 1 DRAFT 2111I85 al. 1984, Appendix Table E-1). The other method was a simple visual imethod which classified the relative degree of embeddednessI of the surface substrate with fine particles (PIatts et al. 1983) Specific 1 categories of embeddedness are defined in Appendix Table E-2. ' 2.2.2.3 water Depth and Velocity 1 Water depth and velocity were periodically measured to provide addi- tional information on the physical characteristics influencing incu- bation conditions at each study site. hater depths were obtained using a top -setting wading rod while collecting water velocities in selected ' locations at each study site. water velocities were obtained with a Marsh-McBirney (Mode', 201) flow meter using procedures described in ' ADF&G (1984) . ' 2.2.2.4 Turbidity Turbidity samples were collected in clean 250 ml Malgene bottles. ' Bottles were filled approximately two-thirds full and stored in a cool, ' uniform environment until analysis could be completed. Samples were analyzed using an HF Iastruments (Model 2100A) turbidimeter following ' the procedures provided in the manufacturer's operations manual. I } Embeddedness is defined a: the percent of surface area of the larger sized substrate particles in a streambed which is covered by fine sediment (Platts et al. 1983). 1 23 DRAFT 2/11/85 2.2.3 Chemical Variables 2.2.3.1 Dissolved Oxygen Intragravel dissolved oxygen (DO) measurements were obtained inside PVC standpipes using a YSI (Model 57) dissolved oxygen/ temperature meter. This meter has a probe that is the proper diameter to fit inside the PVC standpipe used in this study. The meter was calibrated at each sampling site by adjusting the observed reading to match that of a calibrated Hydrolab (Model 4140) water quality meter.- A Hydrolab was used to collect baseline DO measurements of surface water at each site. After the YSI meter was calibrated* measurements were collected by lowering the probe to a depth of 35 cm (33.5 inches) inside the standpipe, which placed the probe in near proximity of the perforations in the standpipe (refer to Figure 4). After lowering to the proper depth, the probe was gently agitated to circulate water over the DO membrane and measurements were recorded when the reading stabilized. 2.2.3.2 pH Measurements of pH were obtained with a Hydrolab (Model 4041; water quality meter following procedures described in ADF&G (1984). Intra- gravel samples were obtained by withdrawing a water sample from inside a PVC standpipe with a Geofilter peristaltic pump (Geotech Environmental Equipment) and then measuring pH with the Hydrolab. I 24 DP -AFT 2/11/85 2.2.3.3 Conductivity 1 Conductivity measurements were obtained using a YSI specific conduct- ance/ temperature (Model 33) meter according to procedures presented in ' ADF&G (1984). A calibration curve was developed by comparing con- ductivity values obtained with the YSI meter to those obtained with a ' calibrated Hydrolab meter over the range of temperatures encountered in the field. All values measured in the field were then adjusted on the ' basis of the calibration curve. ' 2.3 Biological Variables I 2.3.1 Salmon Incubation 1 2.3.1.1 Procedures to Install and Remove Whitlock-Vibert Boxes ' In addition to being used as experimental substrate samplers, WVB`s wore also used as experimental embryo incubation chambers to '.secs ' development and survival of chum salmon embryos at the eight primary study sites. As originally designed, each WVB was constructed from molded polypropylene which is 145 x 90 x 54 mm in size and contains two ' chambers. The upper incubation chamber is separated by a grid -like partition from the lower nursery chamber. This two -chambered design, ' however, has been found to resulc in an excess accumulation aT fine substrate particles inside the boxes (D. Reiser and R. White, personal communication). For this reason, the two -chambered design was struc- 25 DRAFT 2111/85 turally modified to fo nn a single incubation/nursery chamber to help alleviate this problem during this study. The modified WVBs were filled with spawning size gravel to simulate natural conditions which were favorable for embryo incubation. To achieve this, gravels were obtained by sifting substrates through wire screens to provide a mixture of gravels which ranged from 1.3 to 2.5 cm (0.5 - 1.0 in.) in diameter. This size range was selected to provide interstitial spaces large enough to separate eggs and alloy free movement of intragravel flow, yet small enough to pack conveniently into the WVB's. A total of 50 fertilized eggs were placed between alternating layers of gravel within each WVB. 2.3.1.2 Artificial Fertilization Procedure Methods used to obtain and fertilize chum salmon eggs for implantation in the WVBs followed those presented in Smoker and Kerns (1977) and are generally consistent with those presented in McNeil and Bailey (1975) and Leitritz and Lewis (1976). A flow chart depicting the general procedure for obtaining and artificially fertilizing eggs is presented in Figure 7. Details of these methods are presented in ADF&G (1984). Care was taken to protect the fertilized eggs from exposure to light and mechanical shock prior to, during, and after the time they were placed into WV8s. After embryos were allowed to water -harden for two hours, they were gently transferred from a large container to the WVBs. the entire process of placing embryos and sifted gravel within the WVBs was 26 GRAFT Artificial Fertilization Procedure START Cophre ::.-nIr■ Fish 03 T►ca Males W Three Fe" es Verify Ripeness of Fish 2 a r I[lll and Skied flab on Reek E01mate Average Egg Olamefer for Eafa1 Fe is +� Fertilise Eggs Ferti is se E"S a Bucket I 600"t Z = F+rst Fsalele Seewd Feade and Both mine and Both Mateo voter Nerden Water harden for 2 Mee for 2 'Marrs Fertiliso Eggs Buckle t 3 Third Fessate aM Seth Metes wilier lierden far 2 heurs Pool Emb►yos and mix Gsntlf in common CQWM w c FiV Each WhMack-VibertSalwitlf Mwture of 30 En+bryM and I/3 - I-GraVd tv l Instal base in Substrate 1 FINISH Figure 1. Flow diagraal depicting the sequence of events which cccurred during the artifi- cial fertilization of salmon eggs and the subsequent installation of artificial incubation chambers (Whitlock - Viber= Boxes) in the streambed. 27 DRAFT 2/11/85 conducted inside a dome tent to reduce potential adverse effects from exposure to the outside environment. Embryos were kept in a water bath maintained at the local water tempFrature and shielded from harmful ultraviolet rays from the sun (Smoker and Kerns 1977). 2.3.1.3 Installation of Whitlock-Vibert Boxes Whitlock-Vibert Boxes charged with fertilized eggs and gravel were placed in artificial redds at each of the eight primary study sites. Six of the primary study sites were used to evaluate er.,.bry❑ survival. In these sites, WVBs were placed within the streambed based or a random selection of grid coordinates on a site map, in an attempt to represent the range of environmental conditions present at each site. At the other two primary sites, WVBs were primarily uses to evaluate embryo development. At these sites, WVBs were placed -at a single location in the streambed to allow embryos in all WVBs to be influenced by similar environmental conditions. One additional site used to assess embryo development was physically located within the same site used to evaluate embryo survival in Slough 11. For specific details on the site selection procedures, refer to Section 2.1. At each study site, streambed materials were loosened with a high pressure jet of water generated by a Homelite gas -powered water pump. After thoroughly loosening the substrate, a plastic bottomless bucket (19 liter; 5 gallon capacity) was forced into the loosened substrate while the contents were extracted by hand to a depth of 24 to 25 cm {8 28 IORAFT 2/11/85 to 10 in.). The bucket prevented substrate from collapsing into the ' excavated hole and allowed holes to be excavated for several locations on the day prior to installing Whitlock-Vibert Boxes. Two WVSs and one ' PVC standpipe were placed in each excavated hole after the hole was ' refilled with the surrounding gravel. A nylon cord served to attach each WV8 to a large steel spike (30 cm; 12 in.) which was marked with ' orange surveyors flagging for future identification. The location of each WVB was also determined using standard survey gear. 1 1 2.3.1.4 Removal of Whitlock-Vibert Boxes ' Whitlock-Vibert boxes were later removed by locating each metal spike and nylon cord and tracing the nylon cnrd to the point where the cord ' entered the substrate (Plates 3 and 41. Gentle upward pressure on the cord and simultaneous removal of surface substrate materials allowed the ' box box to be withdrawn from the substrate. Upon withdrawal, each was placed inside a plastic container to retain fine materials and placed inside a large cooler with water which kept boxes and embryos from ' freezing. After all boxes were removed at a site, the cooler was transported to a heated work space, at which time the embryos present in 1 Substrate fine from each box were removed and preserved. and materials the boxes were bagged, frozen, and stored for later analysis. All ' unhatched embryos were preserved in Stockard's Solution1. An unbuffered ' solution of 10% formalin was used to preserve alevins. ' 1 One liter of solution is comprised of 50 ml formaldehyde, 40 ml glacial acetic acid, 60 ml glycerin and 850 ml distilled water. 1 1 29 I ,--J 1 FA lJ CRAFT V b� ►i 41 0& a 1 31 DRAFT 2/11/85 2.3.2 F1 atwo rvns During the winter field program, large numbers of flatworms �Turbel- laria) were observed to be present in WVBs retrieved at several sampling sites. The presence of they-e flatworms appeared to coincide with the absence of some embryos from WVBs. Therefore, an experiment was designed to determine if the flatworms were related to the disappearance of embryos. Eight WVBs were each filled with gravel and 10 dead embryos (free from fungal colonization) free of flatworms, and buried to a depth of approximately eight inches in two areas. Four of these WVBs we buried in areas where flatworms were observed in greatest numbers (Slough 11) and the remaininq four WVBs were buried in an area where no flatworms had been previously observed (Side Channel 10). The WVBs remained in the gravels for a period of three weeks. At that time, one WVB at each site was removed approximately every two weeks thereafter until all WVBs were removed. Upon removal of a WVB, the number of dead embryos remaining inside were determined and the relative density of flatworms was visually assessed. 2.3.3 Analysis of Development and Survival of Embryos 2.3.3.1 Embryonic Development 1 The stage of development of embryos was determined by observing pre- i served embryos under a dissecting microscope at 3X magnification. All embryos were initially preserved in Stockard's solution, which was 32 I DRAFT 2/11/85 1 selected because of its reported excellent clearing properties of the ' outer egg membrane (Velsen 1980). In this study, however, the solution did not adequately clear the outer egg membrane. Therefore, it was ' necessary to remove the outer membrane of the majority of preserved embryos to determine the stage of development. For the purposes of this study, the four basic periods of embryonic development (cleavage, gastrulation, organogenesis, and post -hatching) ' were further subdivided into twelve distinct stages as identified by ' laboratory examination of preserved chum salmon embryos (Table 2). These particular stages were selected to establish a foundation for comparisons between sites. The first eleven stages correspond to the period prior to hatching. Stage 12 is a general category which includes all post -hatching alevins. Plates 5 through 8 show chum salmon embryos at selected stages of development. 1 ' 2.3.3.2 Embryonic Survival ' The percent survival of chum sabion embryos was determined at all primary sites except upper Side Channel 11. Whitlock-Vibert Boxes 1 containing embryos were removed, placed in a cooler, and transporteC: to ' a heated field station where embryo, were removed from the boxes. Live and dead embryos were distinguished by visual inspection and ent,merated. In most cases, live embryos were easily distinguished from dead ones by appearance. Live embryos were rather translucent and free from fungus. Most dead embryos were opaque and were often colonized by fungus. n LJ 33 M k M S. ■ k ^ ƒ @ c1 °C V.; § } 6 I 0 u « § § �: c . : 3 ; § a IC 5 fj No. �c \ 0� _ 2 22 41} 2 § 2 � S 2 » 2 i Oki%, a■ ■ ! ■ \ \ 6 c 6 , , a _ .� c E s — c a �a z /�cc a CL 2 Al—� �■ j �� ©� a 2 7 d\ f \\ 014--a Cck k k �j 0\ § � � ■ k ; ! � a ` 2c li C _ on - - _ P. do _ o 2 + 0 2 � �2 � k 2� ■� � � 34 GRAFT I r HI now Plate S. Various stages of embryonic development of chum salmon from fertilization to complete yolk -sac absorption. 35 CRAFT HEAD OF EMBRYO WITH WELL DEVELOPED EYES YOLK VASCULARIZATION WELL REVEL SPED DEVELOP DORSAL IDEVELOPII ANAL Fit STAGE 10 A xE 10 3 LOPING OC FIN Plate S. Head W and body (g) of a chum salmon embryo at Iite organogenesis. 37 DRAFT 2/ 11/85 Missing embryos were considered to be dead. Errtbryos were placed ir. Stockard's solution and returned to the laboratory. 2.3.3.3 Embryo Survival Control To assess embryo mortality due to handling, three additional WVBs from each incubation study site were charged with fertilized eggs and handled in the same manner at each study site. These WVSs were placed in Slough 11 in an area that appeared to represent highly Favorable incubation conditions. After two to ten days, oni of the three WVBs from each study site was removed and as,essed in the same manner as that pre- viously presented for assessing percent fertilization. Any differences in percent fertilization between eggs not handled (i.e., in stream incubation trays) and those handled during placement of WVBs (i.e., the first control box removed; were attributed to handling mortality. One of the remaining two WVBs was removed at eye -up stage and the other at 100 percent hatch stage. These survival estimates were assumed to represent survival under optimal incubation conditions. 38 I DRAFT 2/11/85 I 1 3.0 RESULTS This section is divided into three parts: 1) a description of selected physical and chemical characteristics of individual study sites and various habitat types (i.e., slough, side channel, tributary and mainstem); 2) a summary of embryo survival and development data collected at individual study sites and habitat types; and 3) an evaluation of the influence of selected physical and chemical characteristics of habitats on the survival of chum salmon embryos at I study sites and among habitat types. Results in this section are shown in several types of figures. Three of these figure types warrant a designation of symbols, namely box -and - whiskers plots (or boxplots), scatter number plots, and scatter box plots. Boxplots are used in this report to summarize water temperature, dis- solved oxygen, p8, and conductivity data. The format basically follows that used 6y Vellenan and Hoaglin (1981). The boxplots as presented here were computer generated by the microcomputer program 5Y5TAT (1984). The following example displays ail the symbols used in the baxplot figures of this report. i 1 I 1 39 DRAFT 2/11/85 ------------ d c Measured values (i.e., dissolved oxygen, water temperature, etc.) from each study site comprise a data batch, which is ordered from lowest value to highest. Specific symbols used in the boxplot figures of this report are defined below. Symbol Representative Term a, b Tower and upper hinges (about 25 nercent of the way in from each end of an ordered batch) c H-spread (the difference between the hinges; middle half of the data batch) d miniir-um adjacent value [lower hinge - (1.5 x H-spread)] e maximum adjacent value [upper hinge + (1.5 x H-spread)] + median (middle value of the batch) * outside value (outside of the adjacent values) D far outside value [outside of the following range: loner hinge (3 x H-spread) upper hinge + (3 x H-spread)] ( 3 notches (represent dpproximately a 95% con- fidence limit about the median) defined as median 1.58 x (H-spread)/NPf Scatter number plots are used in a number of figures in this report to summarize water temperature, dissolved oxygen, pH, and conductivity data. Each number represents the number of occurrences in single integers (1-9) at that point. Letters are used to denote 10 or more occurrences, beginning with "A" (A=10, @-11, F-15, etc.). EN I DRAFT 2/11/85 I 1 1 Scatter box plots are used in several figures in this report to sum- marize survival data. Each box represents one occurrence at t. at point. 3.1 Comparison of Physical and Chemical Characteristics of Stuff Sites and Habitat Types 3.1.1 Physical Characteristics ' 3.1.1.1 Water Temperature Water temperature data presented in the following sections include instantaneous surface and intragravel water temperatures measured at ' both primary and secondary sites, and continuous intragravel water ' temperatures measured only at primary sites. 1 3.1.1.1.1 Instantaneous intragravel_Water Temperatures Comparisons of instant -nexus intragravel water temperatures (°C) measured within standpipes, grouped by habitat type and study site, are ' presented in Figures 8 and 4, respectively. Because temperatures undergo marked variations over time, median values presented for study sites and habitat types are strongly influenced by the time of year at which individual temperature measurements were recorded (refer to Appendix C). For this reason, comparisons between median values have not been made. The figures can be used, however, to show differences in the range of intragravel water temperature variations associated with individual study sites and 'habitat types. 41 rjRAFr Al E W W W W H dw 33 wi W an F , 1 1 f f r f r r x p ■! r i $ � i � e w LL 42 GRAFT W W a. W W H t 0 J W an oc 1 1 1 ! 1 1 1 1 1 , 1 1 1 ! 1 i 1 1 1 1 i— y'R 41 Ri 1 1 i.r r L 1 1 r r 1 ! 7 1 i i ..+aJ ar ■ i L10 1 1 1 1 V1 ! ! 1 1 1 ! 1 , !» 1 , ! , , ! I 1 1 1 ��♦a L N 1 r 1 1 l 1 1 1 1 1 1 o r C Ile 1 1 1 1 1 r 1 1 1 �} cc C 1 �► 1 1 1 r l w 1 1 l 1 1 1 1 1 1 I 1 1 1 1 ,! r 1 r I d Ni■i f +riwwi 1 1 i i i i LH 39 �AiR 1 1 } 1 1 1 1 f 1 1 ! 1 1 1 1 1 1 1 1 1 1 { ■ 1 1 1 � 1 1 1 1 1 1 � 1 1 +.• 1 Li ✓Z V Ln [!] to >C 43 DRAFT 2/11/85 Generally, data show that instantaneous intragravel water temperatures were least variable in mainstem and slough habitats and most variable in tributary and side channel habitats. This is likely due to the varying degree of influence of upwelling between these habitat types. 3.1.1.1.2 Comparison of Instantaneous_ Surface and Intragrave_l Water Temperatures A comparison of instantaneous surface and intragravel water temperatures measured at standpipe locations in slough, side channel, and tributary habitat study sites are presented in Figures 10-12, respectively. The combined data from the three habitat types are presented in Figure 13. Data used to develop these figures are presented in Appendix C (Table C-2). In each figure, there appears to be a direct relationship between surface and intragravel water temperatures. This indicates that intragravel water sources strongly influence the temperature of the surface waters of each habitat type. This is likely caused by the presence of upwelling intragravel within each habitat type. The effect appears most pronounced in slough habitats (Figure 10), which is likely related to the relatively greater influence of upwelling in this habitat type. r 44 ORA" 1 1 i 1 1 WATER TEMPERATURE ISLOUGH1 INTAA68AVEl VS Ste&FACE 140 oft .1 M IT. M 6•u00 3.004 � om .000 9.40 9-}00 • _._ 1.vo4 l t 2 2 l I l l 1 1 2 122 l i I 1 2 3 1 I ! T l l 1 I 1 I i 11 12 li t s 1 s �l 11 !z iz iii ui 3 i3 3 i i sill 1! i I 1 2 1 1SIY1t li li ll 1 11 i l l l ! 12 211 l !l ll l .jW 1.�o 2.WO ;.M 4.600 Yi.U<4 9i100 -uV4 A•wA] a.d60 SURFACE WATER TEMPERATURE (*C) Figure 10. Relationship between intragravel and Surface water temperatures (°C) measured at standpipes within slough habitat of the middle 5usitna River, Alaska. a.0" I,OM idM ILM Cole LIN LOW =.IM .M 45 CRAFT WATER TEMPERATURE ISIDE CHANNEL] IMTRAGRATEL VS SURFACE 4V 2.000 4.000 +.000 9.�V3 10.�" i 12.1M I 1O.No + l Ili 3 w .a lr I W i Q: Q d 4 6.00 + n 1 Q i i Z 1— i 4.001 + [ l 3 1 1 2 l 1 l [ 111 It I1 c l 3 i s li 1 .oat + I1 .004 i.000 1.111 i.01► 1.000 10.000 SURFACE WATER TEMPERATURE VC) :2. W0 14.00 - •__ ------ Figure 11. Relationship betwean intragravel and surface water tagwratures ('C) measured at standpipes within side channel habitat of the middle Susitna River. Alaska. UM ILOW lo.@* LW i I ► 4,004 ;.000 12.000 t4.D00 .N 46 WATER TEMPERATURE ITRIRUTARTI INTRAHAVEL VS SURFACE ��5�i 1.�104 :.940 i.0v3 4.u04 5.v:: 8.J64 7.�+. 2.004 WOW f • �.VW ► F Q. V�1 • ■ i :1v �. W � * ` W Q F+ W x aiwi 1.JW i.00v 3.000 4.000 5.400 Q.m ".00 SURFACE WATER TEMPERATURE M) Figure 12. Relationship beintragraval and surface water taaperatures {QC} measured at standpipes within tributary habitat of the middle Susitna River, Alaska. 4. m. LOW 7.00 •.00 5.000 4.00 :.400 :.oro ■ LON .ea0 LW 47 GRAFT WATER TEMPERATURE [COMBINED HABITATS1 INTRAGRAVEL VS SURFACE l4.iiaY ► ' l 1 l i ! Ia.,,ae 1 1 ' isr ,-► t � ! 12 11 1 1 > ` 3 21 1 1 ' t CC "2 �.JaO * 2 1 R 2 21 l 1 ► p 11! I It t 1 1 �2 t cc 1 W i 11 1 l 1 i t I.YtI + ! 2 ► I 1 1 1 23 1 11 Z14 t 2 2 M H 22 1 k 12im i is 21 i s111212 LOH + 1 2 126122 21 12 ► i 21t I 223111 1 l 211 t lI lilt 31 1 i l 22 1 .Oat 32 + 000 2.m 4.000 ON 1.00 10.000 MON I+.040 SURFACE WATER TEmpERATURE (" C) Figure 13. Relationship betwm intragravel and surface water tewperatures ('L) wlasured at standpipes within Clough, side thannal. and tributary habitats of this griddle Susitna River, Alaska. 48 GRAFT 2/11/85 I I I I I I I 3.1.1.1.3 Continuous Intragrave3 dater Temperatures Continuous intragravel water temperatures were measured at 18 sites in the middle Susitna River during the period from September 1983 to June 1984. A complete presentation of these data are included in Appendix A. This section is limited to a summary of a portion of these data, focusing only on intragravel water temperature data collected at the primary study sites in slough, side channel, tributary, and mainstem habitats used to evluate chum salmon emb,,, survival and/or development. Figures 14 through 16 present the intragravel water temperature data collected at primary slough habitat s'cjdy sates. From these data, it is apparent that intragravel water temperatures in slough habitats remain relatively stable from October to May, typically ranging from 3-4°C. These relatively warm temperatures indicate that the source of the intragravel water is likely upwelling. Figures 11 through 19 present the intragravel water temperature record collected at primary side channel habitat study sites. These data show that although intragravel water temperatures in side channel study sites retrain relatively stable from October to May, they show more variability over time compared to slough habitats. This indicates that although the source of the intragravel waters in side channel habitats is likely upwelling, other water sources, such as surface water dcwnwellkng, may influence the intragravel water component. I 49 CRApr w a t cc t i 4 L 1 4J ' 77 � LL r [ �.) 3aniba3dVf3l a31V* 9 50 C RA" oc s m w z t u w C y 9 z ( 3.) 3anldaum31 a31VM us L V L�13 a CV L ''!sue ■ Y � 347 e+1 �A.r Y � CI.M iq L L N 4 39 C r i/7 a1 C y r r. C1 CC A Y �Y tj L. N 51 GAAF7 x ,4L i c t W d m zC'Z �w tarr rt p3 Y cc 41qr A � t to 0 q fir. W N L of C � 'r 0 oc _ qMM b fJ L. r� �+ Qi 0 [ 7. ) 3univa3dn31 a 3.LVAA 52 CAA" Y d '.7 dc t ( oa ) 3univMUM31 U 31VIA 53 GRAFT cc 0. t cc t (3.) 3anida3dVf31 U31VAR 54 I lJ I I I 0 I I I ( Do) 3WnlVW3dM31 U31VIA } t Ac 4L t at t x C RAFr 55 DRAFT 2/11/85 In Figure 20, intragravel water temperatures measured at three sites located in Fourth of July Creek are presented. Althcugh the data record contains several gaps, the pattern of seasonal temperature variation is evident. IntragraveT water temperatures are relatively high ii early September (6-8°C), decrease rapidly to near O°C in late October, and remain at or below 1°C, for several months before increasing in March and April. The gradual increase in March and April is follcroed by a relatively sharp rise in temperature in early May. This indicates that the source of the intragravel flow at Fourth of July Creek is likely subsurface flow originating from surface waters rather than urwelling. The intragravel water temperature record collected at the primary study site at Mainstem RM 136.1 is shown in Figure 21. Although the record is discontinuous, the seasonal temperature pattern is evident. In late September and early October, intragravel water temperatures decrease to near O°C and remain relatively constant until early May when they begin to rise. This indicates that the source of the intragravel flow at this mainstem site is likely subsurface flow originating from surface waters rather than from upwelling. 3.1.1.2 Substrate Composition Two methods were used during this study to evaluate substrate composition at primary study sites: a Whitlock-Vibert Box sampling method and a McNeil sampling method. Substrate composition data obtained using each of these sampling devices at primary study sues are presented in Appendix D (Tables D-1 and D-2). s i ( o• ) 3anivuuw31 U31YAA 57 GRAFT r (3.) 3 vniva3dmn 4 31VIA H {. w L •i ZT M � r 'was t "~ V as rr r+ � Cps ~ q � r L Ly e A v a t C �� L G q C I%r aN 58 DRAFT 2/11/85 3.1.1.2.1 Comparison of McNeil and Whitlock-Vibert Box Samplers ' To determine whether the two substrate sampling methods used in this study provided comparable results, the dry weights and percentage of ' substrate particles less than 0.2 cm (0.08 in) in diameter collected using the McNeil sampler were compared to the dry weights and percentage tof subs rate particles less than 0.2 cm (0.08 in) in diameter collected using the Whitlock-Vibert boxes (Figures 22 and 23, respectively). In both cases, there appears to be a relatively good relationship between the results obtained with the two types of samplers. For this reason, only the McNeil substrate composition data were used in further ' substrate analyses in this study. A comparison of sampling devices for individual substrate size classes is presented in Appendix D (Figures ' D-1 to 0-7). 3.1.1.2.2 Substrate Composition at Study Sites r The percent dry weight by size class of substrate samples obtained with 1 the McNeil sampler over the range of substrate conditions observed at the nine primary study sites, with the exception of Mainstem (RM 136.1), are presented by study site and habitat type in Figures 24 and 25, f respectively. Data for the Mainstem (RM 136.1) site are not include❑ 1 because the excessively large substrate particles at this site prevented the proper use of the McNeil sampler. Two McNeil samples, however, were obtained at an alternative mainstem location (RM 138.9) which appeared to have substrate similar to that typically selected by chum salmon for spawning. These two samples have been included in the Figure 24 presen- 59 GRAFT - x m a$ _ > v; Y. ❑ p ,O N - s pxp J = 3 Xg�s M (aoat x 0) LH913M Akio 113NOn 60 x G m m m v $.- C; Y V a' 40 CC 3 J w r 1 y 113NOM1 1 61 DRAFT RE `m w w '� ku iL R�_ Y M i M a r a r r � t � U . J r � Y _ _. ■ uj 0 i Y 6 W � W 7 7 A Im IN90b3d 62 CRAFT ■ a -- ■ 0 _ R L] W _ ■ a ul �- i co o - R w �N3Dd�d 63 DRAFT 2/11/85 tation for comparative purposes. In addition, the percentage of substrate materials in each ;;f the three smallest substrate size classes (hencefon rd termed "fines") for each of the above nine primary study sites, grouped by study site and habitat type, are presented in Figures 26 and 27, respectively. The total height of each bar represents the combined percent of fines, whereas, the internal bar divisions correspond to individual fines size classes. In general, these data illustrate that slough habitat study sites contain smaller substrate materials ind greater amounts of fines than other habitat types. This is likely the result of lower water velocities within these habitat types. The mainstem habitat study site had the largest substrate materials and least amount of fines present whereas the side channel and tributary habitat study sites contained intermediate amounts. The percent composition of substrate materials collected using the McNeil sampler in areas utilized for spawning by chum salmon at study sites and grouped by habitat type, are presented in Figures 28 and 29, respectively. In addition, the percent substrate composition of fine substrates collected using the McNeil sampler at study sites utilized for spawning by chum salmon are presented in Figure 30. In all cases except the site at Mainstem (PM 138.9), the substrate samples were collected within approximately 5.0 feet of a natural chum salmon redd. The data for Mainstem (RM 138.9) were not collected at a chum salmon redd, but rather, at a site that appeared to have a similar substrate 64 I i I f 0 I 1 1 I 1 1 CRAFr J ■ V r w w r � r Y s • i � s -- - r► 9 e w r v Y1 • � V ��_ - - - 7 �^ ti+ W LU N ut00 w MO ~ oeN tu 41 CQuC = L•.r V VI R W N F 6i L S 7 } 7 CJ1 IL 1H30USd 65 GRAFT - W F i Y a - o O Q � G t rr F _ m Y YY a+ Y Y Q. M t v cc, � -- J LU N Q r N 4c Y Y M L 7 W G Y � � iq ■ ub s c N Y c u Y Vv p a—u i 2 N � Y L 7 LL w:Hr--rr-1 66 1 1 1 1 1 1 1 1 1 1 1 1 a a ■ iM s � a w x ■ a y r 1N3*V3d 67 GRAFT GRAFT • o e t h � •w v T M r v � ■ CC � N V:L�. VA ullow w lc i - Y ■ am t L W _._ LC R Y M a� Y Q ~ L • v w � ■ ■Y M LQ L —.�— eIE40 D J n Cy i a w 1NBOVU 68 CM" � ■ � ---- � ■ d .. - . _�■ f � �� $ ■ � . � - -a- f- a � dc _ § ����. /: � ■ � � ... . � • . ■ - a _ 2 ... . �. - � , ( �- z �� . '� .._ 2■�-. �©=g■ -- - . & ■ � z WE . �0 � 04 Imaouad 69 r-1 DRAFT 2/11/85 compoisition to that in areas utilized for spawning by chum salmon. It is Included for comparative purposes. The variation in substrate composition of salmon redds is relatively greater for the three largest substrate categories than for the three smallest (Figure 28). For example; for substrates 1.0-0.08 in. diameter, the percent composition varies from a low of 23% for the mainstem site to a high of 47% for Slough 10. This represents a difference of 24%. In contrast, for the three finer substrate categories, the greatest variety between the sites in each category is 3.0%, 6.0% and 15.0%, respectively. Substrate composition for the finest three size categories are compared between study sites in Figure 30. Of all sites evaluated, two sites [Fourth of July Creek and Slough 11(Subsite 8)] contained less than 10% total fines. Three additional sites [Slough 10, Mainstem (RM 138.9), and Slough 211 contained less than 15% fines, and one site (Upper Side Channel 11) contained greater than 20% fines. It is noteworthy that both of the sites with the greatest amounts of fines (Upper Side Channel 11 and Side Channel 21) also contain extensive areas of upwelling. These upwellings undoubtedly act to reduce the deleterious effects of increased amounts of fines in the streambed. The substrate composition of chum salmon redds is compared between samples collected in different habitat types in Figure 29. In general, slough and side channel habitat study sites contain relatively greater 70 I DRAFT 2/11/85 1 1 1 1 1 1 1 1 1 e 1 1 1 1 1 1 1 amounts of fire substrate materials and relatively lesser amounts of larger substrate materials compared to tributary habitat study sites. However, areas where salmon established redos in each habitat type (Figure 29) contained fewer fines than the range of substrate materials available in each habitat type (Figure 25). 3.1.2 Chemical Variables 3.1.2.1 Dissolved Oxygen Comparisons of dissolved oxygen concentrations (mg/1) measured in surface and intragravel waters in slough, side channel, and tributary habitat study sites are presented in Figures 31-33, respectively. These data, grouped for all study sites, are presented in Figure 34. Similar plots for dissolved oxygen, expressed as percent saturation, are included in Appendix C. In each figure, there appears to be a general relationship between surface and intragravel dissolved oxygen levels indicating a relationship between upwelling water and surface waters within each habitat type. The relationship appears strongest for tributary habitat study sites (Figure 33) and weakest for slough habitat study sites (Figure 31). It is interesting to note that the relationship for slough habitat study sites does not appear uniform over the entire range of concentrations, being much weaker (i.e., wider scatter of points) at low and intermediate values than at higher values. 1 71 LOW l4.OM + .lP 1 12.00 + IO.MO ■ it E LU Y r z 3 � W X 7 ❑ t ; CC LU a.4M + l i t > 0 H G 4.Oti0 + Figure 31. DISSOLVED OXYGEN 13LOU6H1 INTRAGRAVEL VS SURFACE LIM a. ooag.%o 10.0M i 1. w t2.000 I3.000 14.0 r 1 i is 1 ; 1 ! 1 12 I 2 ! 1 1 1 1 i1 11 11 111 1 + 1 3 1 21 11 11 2 31 1112 1 y ; 1 t i 2 1 21 M t2 211 1 2 ! 12 Ill 1 1 11 = I 1 E1 121 i 11 1 lllill 1 t1111 1 S I I _ E 1121I 1 121 l 11 1 1 1 1 I li 1 I I ll ! l l 1 1 I 1 ! 11 I 1 f 1 1 1 I l I 1 6 tI 1 t 1! 1 I 1 � _ 1.W 11.000 9.000 10.000 II.; e:.000 �13.OM • 14.M0 SURFACE WATER DISSOLVED OXYGEN ,rrlpli] Relationship between intragravel and surface water dissolved oxygen concen- trations (mg/1) measured at standpipes wittsi.1 slough habitat of the middle Susitna River, Alaska. MW ILL 0 MW LNO 4.OM La" OM 72 1 1 1 1 1 CPAFY' DISSOLVED OXYGEN [SIDE CHANNELI INTAAGNAVEL VS SURFACE h.909 '.000 8.d09 4.000 10.000 11.000 1'.000 13.01 14.00 13.01 Idj" 1a. a80 / 1�.000 l 1 i i 41 i r 14.410 1 1 1 ll f I�1 1 2 :.J04 • r Mom W E 1 t Z 311 3 w 1 : 1 a. Joo l l ILM at [ I l < 0 1 Cr 0 1 l > F 0 I l 1 i � I e.u4p • l i l 1 I I r jip� i I i 1 1 I � = 4.4M ` l ► 4.000 s 1 I 2.i11 ! 1 UP &.M '.aoo a.3P7 4.0W 10.400 Il.m 12.000 IT M 14.0d0 Is.700 16.0d0 SURFACE WATER DISSOLVED OXYGEN (mU11) Figure 32. Relationship between intragravel and surface water dissolved oxygen concen- trations {,ag/1} aeasured at standpipes within side channel habitat of the middle Susitna River. Alaska. 73 E;RAF7 DISSOLVED OXYGEN ITOIBUTARYI IHTRABRAVEL VS SURFACE �I.v64 1:.stw ...uGc7 ..500 fi.aro 3.3� I4.u00 • 1�.04Q l 1 1 I 1 t • 15.304 I I 1I.060 ► 7 13.000 ...30� • I2.564 ir LU E * i2.�100 J y 1 � 5uu Dx ► 11.300 l tr =3 I I J. w J:1.a40 • • 1i.000 ~ z U. 1 1 ► 10.300 la.ao� i 10.000 4.30 ! I ; F.904 f.M ' i1.J00 11.5 li.�J�1 1:.500 13.000 ;.500 14.06 SURFACE WATER DISSOLVED OXYGEN (mg/1) Figure 33. Relationship between intragravel and surface .rater dissolved oxygen concentrations (mg/]) measured at standpipes within tributary habitat of the middle 5usitna River. Alaska. 74 1 ' DlSSOLYEII DITB>~N ICBNBINED RAW ATZI INTBABBAVEL VS SOBFACE ..aa node I1.000 i.dod Id.ON ll.eea iZ.001 than 14.0de 1s.000 1�.000 1 t 12 RAO:lL I 1 !3 1 L 111 11 = 1 1ll i l l It 112 I 1 1 I 1 cc E Lando • 1 L 2 SM i! 111L 1 i L Ill it _ 7 22 11 1 1112 t ul 1 L 1 L 1 2 2L 11 I= I 22 I 3 v = 2 11 1I2 2 it ' y' l it ll I2111 x J 8.voa ■ 1 1 I12 1 1 = 1 111 1 I 1 1 0 n11 7 t 1 1 11 1 l 1112 21 1 lilt l 1it 2 11 1 1 ' v t J 4.0e0. 1l 1 II L 1[ L 1 1 1l 1 2 11 1 12 1 1 0 1 1 1 12 L = 1 ' Z p 1 i k lit 1 [ 1 1.aa. 1 1 I l 1 L ' l.a0 � 1 1 11 1 1 12 ! 1 .oDO , r 060 r.ae i.000 }.400 10.080 1l.dOt! 12.d00 Ll:;i li.A00 1"�.ai i0.00d SURFACE WATER ' DISSOLVED OXYQFN [my11] Figure 34. Relationship between intragravel and 1 surface water dissolved oxygen concen- trations (mg/1) weasured at standpipes within slough, side channel. and tributary habitats of the diddle 5usitna River, ' Alaska. 1 75 16.000 L4.0a0 L2.000 10.004 6.000 4.000 .000 GRAFT 2/11/85 A summary of intragravel dissolved oxygen (00) concentration (mg/1) data is presented by study site and habitat ty)e in Figures 35 and 36, respectively. These data show that median 00 levels are generally lowest for slough habitat study sites, intermediate for side channel and mainstem habitat study sites, and greatest for tributary habitat study sites. 3.1.2.2 pH Comparisons of pH levels measured in surface and intragravel waters in 3 s slough and side channel habitat study Sites are presented in Figures 37 and 38, respectively. These data grouped for all study sites are j presented in Figure 39. Because this variable was not measured at all 11 standpipe locations, there were insufficient data for comparable plots for tributary and mainstem habitat study sites. In general, these data show that there is a relationship between pH values measured in surface and intragravel waters in each of these habitat types, with the relationship being weakest for side channel habitats (Figure 38). A summary of intragravel pH levels is presented by study site and habitat type in Figures 40 and 41, respectively. These data show that, with the exception of Side Channel 21, slough and side channel habitat study sites exhibit the same median pH values and are intermediate between the lower tributary habitat study site levels and the higher mainstem habitat study site levels. 76 l 1 P � � � 1 1 1 1 1 � 1 1 1 1 1 1 1 1 1 1 � , 1 � 1 � 1 1 � 1 + s � � � 1 1 1 � � � � 1 1 ; 1 � I 1 1 1 1 , 1 1 � ; 1 � 1 1 1 ; 1 1 1 1 1 1 1 , 1 � ; � 1 1 1 1 11 ; 1 1 1 1 1 � 1 � 1 1 ; 1 w r Ic room" 77 CAAF7 0 • y 1 0 a r 78 Lam CL cc LLI F J LY 7 Q 0 t it Z INTBAGNAIEL YN SURFACE :N 1.200 7.300 7.406 7.500 7.6H 7.700 7.aaa _ 7,a0p 7,500 . i 2 3 • 7.504 7,400 3 2 2 7.400 7. >N ; 7. 300 7.'w i l 7,j00 7.00b 1 i 7.000 a.940 + 1 • 6.100 7.100 712% 7,3p0 7.404 7.500 7.10 71700 SURFACE WATER pH Figure 37. Relationship between intragravel and surface water pH levels measured within slough habitat of the;, middle Susitna River, Alaska. 79 fNMNNVIL " SUFACE r.�o r.+M r.� r.He r.1N r.eM r.9e4 LNG � i ?.ON + ; i 1 r.11ot r.Ip1 i I ' H � r.Zoo 7.200t Q t 7.OM Q ' l 3 : r.Zi70 Y.111 • 1 . i.r00 i.30Q 7.400 7.�e 7.i14 7.7M 7.M11 7'.910 SURFACE WATER PH Figure 38. Relationship bebmen intragravel and surface water pH levels measured within side channel habitat of the middle 5usitna River, Alaska. 80 i i i I i i 1 I a Q t 3 J W t Q v t Q Z GRAFT pH [COMBINED HABITATS] IRTRAGRAGEL VS SURFACE 7.110 7.2% _.'.- +- 7.4ft LW 7. NO taro - 1.201 1.4" 4..06 I �.ote i I I I • I � I s 3 2 2 4 1 2 i 1 1 ! I I 1 l 7.m 1 2 I � ! i 1 � 7.400 1.2e0 7.m 7.600 ?.In O.IM Z200 wW 1.100 SURFACE WATER PH Figure 39. Relationship between intragrarel and surface water pH levels weasured within slough Ind side channel habitats of the middle 5usitne River. Alaska. 1.300 LM 7.5" 1.0" .."s 1 81 GRAFT LLA wo t 1 � 1 1 i 1 1 1 1 1 i i i 1 1 i l i l i i I 1 1 1 1 1 1 1 1 1 I 1 1 1 1 I 1 = 1 t 1 a 1 1 w i y 1 1 1 e 1 1 J J 4 Ch eri c11 N7 Cn � �. ❑2 CRAFT CL W no cc r 1 1 1 1 r r 1 , 1 r 1 1 r 1 r r r 1 1 � , , 1 1 1 , , r , r , 1 , 1 1 i I 1 1 1 1 r l I e r 1 1 , , 1 , + I 1 1 1 1 I 1 1 1 I 1 I 1 + i 1 1 r 1 1 1 1 1 , 1 1 , 1 1 1 / 1 1 , 1 1 , r I 1 i 1 i , , r 1 1 i x r b' 83 DRAFT 2/11/85 3.1.2.3 Conductivity The relationships between conductivity levels (umhos/cm) measured in surface and intragravel water in slough, side channel, and tributary habitat study sites are presented in Figures 42-44, respectively. In addition, these data, grouped for all study sites, are presented in Figure 45. In general, the relationship between conductivity levels measured in surface and intragravel water appears to be well defined for all habitat types except sloughs. In sloughs, the relationship appears to be well defined for surface water conductivity values greater than approximately 200 umhos/cm, but is less defined for values below this po,nt (Figure 42), indicating that surface water conductivities in these habitat types are influenced by intragravel conductivities to a higher degree in areas of upwelling. A summary of intragravel conductivity data (umhos/cm) is presented by study site and habitat type in Figures 46 and 47, respectively. In general, slough, side channel, and mainstem habitat study sites have relatively equal conductivity ranges in contrast to the tributary habitat study site, which exhibits distinctly lower conductivity values. .3.2 Comparison of Embryo Survival at Study Sites and Habitat Types The percent survival of chum salmon embryos and alevins is presented for individual study sites in Figure 48. Two estimates of survival are provided for subsites A and B in Side Channel 21 and Slough 11. subsites A and 8 in Side Channel 21 are distinguished from each other 4 n 84 r f E;R AFT CONDUCTIVITY ISI.OUGH) ' INTSAORAYEL VS SURFACE 100.000 ls0. m 200. M 250. no 100.001) - M. --- 400. NO i SLOW Jo. Do 1 it i ��� + 1 I ]4{7 it I 113i3 • IM.ial ,.� ]1 111241 [ 3 4211111 7�P.aM ■ 1 ]i2 [ 1 121131 221.00d O I t2 21 1 21 l 1 ~ r is ! 1 11 1 l ! l[ 1 5. > t— i 121 a l 2 i l }•. � ! er. M 1 13 i ■ _�' Z Z 11 211 1 O U t! 2 1 4-u. U4u 1I l 3 l = ■ 110.r790 1 ! 12 1 1 i 1 i ll .:4. Yiri 2 [ [ [ • ] i24.000 ' 1 112 1 [ ' ! 00.VA, 150.ON 200.000 256.760 300.000 30.1)w 400.vou ' SURFACE WATER CONDUCTIVITY (umhoslcm) Figure 42. Relationst,'.p between intragravel and surface water conductivity levels (WE hos/cm) measured within slough habit:.' of the widdle 5usitna River. Alaska. gs Maur � IM ISME CIAMEU 1ETEIICEEEEL It =DEFACE :f. 110.000 MAN 2f1.111 MIN mr.00e �Ob.dli . • MAN ! 1 t i i � i11 r 1 i 2M.0p1 S 1 1 E = 1 = Q � S RLM � ■ 1 3 E tu >- a CC V 111.Oe1 Q M a _� D U 100.00e + ! 1 21 l [ t 1 li.01f • 30.006 100.Up0 150.000 .00.000 230.�00 SURFACE WA TER CONDUCTIMY 0mhoalcm] Figure 43. Relationship between intragravel and surface water conductivity levels (poloslcmf measured within side channel habitat of the middle 5usitne River, Alaska. 300.ON ISL 0 19i.416 86 GRAFT CONDUCTIVITT [TRIBUTARY) !NTRACRAYE! Y5 SURFACE :-0# Ia.Wo ei.50L a0.r.: iA.� i2o, M 140.G00 i iw.lwe a E uj 0 100.X" - � t~ t C] � a p w.roa v w. At 11 is :BY. SGv i ► l�ri�1 itkMr lar.aa� t ► MW t w.wr :ir.00e • 11).-A +0.000 ►L.DOO 90-ON 100.700 1'.C.JOU 40.00d 1w.0f0 SURFACE WATER CONDUCTIVITY �urrnos/crn) P gure 44. Relationship betmen intrayravei and •(Irface Tatar conductivity levels Oalhoslcm) measured within tributary habitat of the middle Susitna River. Alaska. 40.00 20.00 87 Q W H t 3 iii t Q v 4C r CONDUCTIVITY [COMBINER HABITATS] INTBASNAYEL 1S SURFACE OM Se.011 lla.ela k�I.a11 "Ll" ULMI IM.O'A =.MO 4*.MO l 1 I lilt 160 11 It 31= 1 1 1 266 22 124 32 _ i l i 1l 2M.MO a 12� ll l 1 2 14 l 1 I _ iin p i lm A 131.401 , l 1s Lail 2 11 ! l 11;:1 13 = li12 1 1 211 Lail 1 11 l tin � 0 i 10.M • 1 l 1 2 i ! i i i I SLOW • • I k22 = i ! ! ! ! .eM • i �11! M.1M lM.M1 121.11/ 2M.lM 2iLW 39LMa iLMa ZIN SURFACE WATER CONDUCTIVITY (Umho*/CM) Figure 45. Relationship between intragravel and surface water conductivity levels (pmhoslcm) measured within slough. side channel , and tributary habitats of the middle 5usitna River. Alaska. 73O.Ma 2N.w T-=1 l4e.Me ILMO MI 88 w �IV a dae a a w� f.J Q LU w ac w i i 1 >! t 1 1 1 + 1 i i i i i 1« 1 I 1 1 1 1 1 1 I r r r e e l I 1 1 1 � 1 1 1 1 1 .. 1 V 1 N a CRAFT V L qp C vo C��iN vt v a'. rn 4 i 89 a MA ca ma W go ac �i em e In w ��yy L�CLw p � r C r L a� V q 39 q 7 r v i Z Ncc 5 Tr m 4 i i r1 C e _ f I f -� f �♦ � w i i i r cm s1 0 C i w �► O �yzyL.� d � � 1 � f � 1 1 I � f I 1 � 1 f qr p rt L4 i GRAFr 90 CRAFT 25 1 i w V i r N7 � N t w � IVAIAvns 1N3OU3d 91 DRAFT 2/11185 because Whit lock-Vibert Boxes containing ferti;ized eggs were installed at two different times (approximately two weeks apart). Subsites A and B in Slough 11 are distinguished from each other because they represent two distinct areas within this slough, and contained embryos originating from different parental sources. Subsite A contained embryos from salmon captured in Slough 11, whereas subsite B sErved as a control site and contained embryos originating from salmon captured at Slough 21, Side Channel 21, Fourth of duly Creek, and Slough 11. Four of the nine study sites evaluated [Side Channel 10, Slough 11 (Subsites A and B), and Fourth of July Creek] had survival rates between 10% and 15%. Of the remaining sites, two [Side Channel 21 (Subsite A) and Slough 10] had survival rates lower than 10% and three [Side Channel 21 (Subsite B), Mainstem (RM 136.1), and Slough 21] had survival rates greater than 15%. Survival of embryos in Slough 21 was more than twice that in any other site. Differences in percent survival of chum salmon embryos and alevins within different habitat types are presented in Figure 49. Equal weight was given to each study site, regardless of the number of Whitlock- Vibert Boxes within each site. The mainstem habitat study site had the highest survival rate (approximately 19%) and the tributary habitat study site the lowest (approximately 9%) with slough and side channel habitat study sites having intermediate survival rates (approximately 17% and 111%, respectively). 92 CRAFT J s Im s s a . e IYAIAwns IN30a3d • �+`•` •fix •L b 93 DRAFT 2/1Ij85 3.3 Effects of Physical, Chemical and Biological Habitat Variables on Embryo Survival at Study Sites and Habitat Types A quantitative evaluation of the effects of selected physical and chemical habitat variables on embryo survival in this study was limited in that large numbers of WVBS at study sites dewatered and froze resulting in the total mortality of embryos in the affected WVB's. Therefore, in order to discern the differences between effects on survival due to dewatering and freezing versus other habitat variables, dewatered and frozen WVBs were removed from further analyses. This resulted in vastly reduced embryo survival data to analyze the effects of other physical and chemical variables on embryo survival. 3.3.1 Physical Variables The effects of dewatering and freezing on embryo survival within habitat types and at individual study sites are depicted in Figures 50 and 51, respectively. in each figure, the estimate of the total percent survival of embryos in study sites and habitat types are presented as the left bar, and the percent estimate of survival of embryos at the same study site or habitat type after eliminating dewatered and frozen samples as the right bar. The difference between the left and right bars within a study site or habitat type represents the proportion of r the embryo mortality attributable to dewatering and freezing. 94 trRAR 4c mo M7 IVAIAmns iN3odu 2 W H y x O b r •i^ ey� � rrsYrr 4 Q Z L t r N t N •+ C 4i EGG � 1 ❑ ❑ Y r � � v oe W ra� a �■ Q � C N y y M3 ~ co M = fl Q► � �..+ K i w ICU a rn U. 95 CRAFT er _ LL Y 019 = W ! V 7 Y Y M i � Y N ! � ''s ■ ^ J Y G A T C V - O Y — Lid L gw b C� M 7 a ■ 7 K ' V ❑M� ups 17l V idAiANns iN30a3d m DRAFT 2/11/85 The data in Figure 50 show that when dewatered and frozen samples are taken into account, survival is highest in mainstern and slough habitat ' study sites and lowest in tributary and side channel study sites. However, when dewatered and frozen samples a e excludPd from the survival estimates, side channel habitat study sites exhibit the highest survival rates followed by mainstem, slough, and tributary habitats. ' Such differences are likely attributable to differences in the degree cf influence upwelling has in each of these habitat types. The relatively high survival indicated for the mainstem habitat, however, is ' likely due to the consideration that was taken to specifically select a site which would not dewater and freeze (see Section 3.2). For this ' reason. care must be taken in the interpretation of these numbers. The data also show the variable nature dewatering ano freezing effects ' had on embryo survival at individual study sites of a particular habitat type. The absence of any bars associated with Side Channel 21 (Subsite A) indicates that all implanted embryos at this site dewatered and froze. The study sites least affected by dewatering and freezing included Sloughs 11 (Subsite B) and 21, and Mainstem (RM 136.1). Lack of freezing in the two slough study sites was largely due to the influence of upwelling which served to keep the sites ' buffered from both dewatering and freezing, whereas the absence of freezing at Mainstem (RM 135.1) is likely due to the consideration that ' care was taken to specifically avoid this problem during the site ' selection process. Of the remaining study sites, Side Channels 10 and 21 (Subsite B) were influenced most by dewatering and freezing, followed 97 DRAFT 2/11/85 in decreasing order by Slough 11 (Subsite A), Fourth of July Creek. and Slough 10. The relationship between survival of embryos and the percent of fintr substrates ([ a.Q8 in. diameter) within WV8s removed from artificial redds within study sites is presented in Figure 52. In general, embryo survival decreases with increasing amounts of fines in the substratf. The four points in the upper right hand portion of this figure which appear to contradict this trend were located in areas of major conr_e-t- tration of upwelling. It is likely that the relatively high survival it these sites, which have high concentrations of fines, is related to the relatively higher rate of intragravel flow at these sites. The relationship between survival of embryos and intragravel wafer temperature at study sites is presented in Figure 53. Based on the data presented in this figure, there does not appear to be a relationship between these variables. 3.3.2 Chemical Variables The relationships between selected water quality variables (dissolv,!d oxygen, pH, and Conductivity) and embryo survival at all study sites are depicted in Figures 54-56. Plots ire each figure are derived from data presented in Appendices C, p, and F. In cases where multiple measurements of water quality variables were present, the lowest measured value was used in the plot. 98 Crum W ' C•� 31 y y i t ' Cc p � Z U ��• N } w ti 4 L 9) 4 rn r� 1VAIAidn9 I N3f}!!3d I R U Z) _ 13 1 r r u Q } e i } w M W L rs � ^ cc Y. IVAiAuns LN30ti3d 100 GRAFT w p E a y _ 1Y m a ` � Q 1 C.I i �- L7 IVAlAuns IN33U3d 4 3 a W 101 Cyr r M co Cl F• li 13 Yr M r � n w �•, f w A y y O L CC M r '' ❑ -- L ~Y A �+ In m O L 7 nrnlnwns IN3083d 102 � G - � ■_ � r c 0 � 0 a � e - � � � s > ■ � � - ■ ]¥mAwns iN30H d CRA" o -� _ 2 Q_ » 2 2 ■ o � �- � - � �■ ■ - ���■� _ \ � �- � M IR k � & 103 DRAFT 2/11/85 There was no strong relationship identified between any of the water quality variables evaluated and the percent survival of embryos. For this reason, plots grouping study sites by habitat types were not constructed. is the plot for conductivity, a relationship was not evident. The plot for pH contained too few data points to enable any firm conclusions to be made. However, the absence of high survival values at low pH indicates the pH may affect embryo survivai at low pK values. A similar pattern is evident with dissolved oxygen. No strong relationship is evident between embryo survival and dissolved oxygen (DO) at DO concentrations greater than 2.5 mgll, whereas at a0 concen- trations less than 2.5 mg/l survival rates are near zero. 3.3.3 Biological Variables 3.3.3.1 Develo - nt of Chum Salmon Embryos Data on development of chum salmon embryos are presented in Appendix F. Data is reported for eight study sites: Fourth of July Creek, Sloughs 10, 11, and 21, Side Channels 10, 21 and Upper Side Channel 11, and Mainstem (RM 136.1). The majority of these data were taken from experimental development sites established by ADF&G. However, a limited amount of data was also obtained from natrual redds and these data are included here. 104 I DRAFT 2/11/85 3.3.3.2 Flatworms In this study, a relatively 'large proportion of embryos were missing at the time when Whitlock»Vibert Boxes (WVBs) were removed from the ' substrate. The number of embryos missing from each WV8 is reported in Table F-2 of Appendix F. The mean number of embryos missing at each site is expressed as a percent of the total for each site as follows: Fourth of July Creek (22%); Side Channel 10 (1.2%); Slough 10 (35%); Mainstem (RM 136.1) (g%); Upper Side Channel 11 (80%); Slough 11, Subsite A (32%); Slough 11, Subsite B (13%); Side Channel 21, Subsite A (3) ; Side Channel 21, Subsite B (8%), and Slough 21 ;9%'). 1 At the time when embryos were removed from WVBs, it was observed that a ' large number of flatworms were usually present in boxes where large numbers of embryos were missing. Therefore, the relative number of flatworms present in each WVB was ranked at the time of removal and an ' experiment was initiated to attempt to deterrri ne the rate that embryos disappeared from WVBs once they were dead (Table 3). 1 I I I I 1 105 DRAFT 2/11/85 Table 3. Condition of dead embryos at time of removal from substrate. Fla tiro mn Sample No. Embryos Fungal Abundance Location dumber Date Recovered Condition Rank Slough 11 1 28 March 1984 10 of 10 low 3 Side Channel 10 1 30 March 1984 10 of 10 none 4 Slough 11 2 10 April 1984 C of 10 medium 3 Side Channel 10 2 13 April 1984 10 of 10 low 4 Slough 11 3 17 April 1984 10 of 10 high 2 Side Channel 10 3 17 April 1984 10 of 10 low 4 Slough 11 4 2 May 1984 10 of 10 high 3 Side Channel 10 4 2 May 1984 10 of 10 low 4 * All Whitlock-Vibert Boxes containing embryos were installed in the streambed on 2 March 1984. 106 3 k DRAFT 2/11/85 I 4.0 DISCUSSION A discussion of the physical and chemical water quality of incubation habitat conditions for chum salmon and their relationships to mainstem discharge Is presented in this chapter. ' Incubating embryos require a supply of water which is of suitable temperature, contains an ample concentration of dissolved oxygen, and is free of toxic substances. In addition, the supply of water which reaches the embryo must be replenished at a rate sufficient to remove metabolic waste products. Therefore, the successful development of embryos is directly related to both the physical and chemical charac- teristics of the source of water surrounding the developing embryos. i I 4.1 Physical, Chemical, and Biological Variables Associated with Chum Salmons Incubation Habitats 4.1.1 Upwel l i rg In the middle Susitna River, adult chum salmon have been observed to favor areas containing upwelIIng as sites for spawning ' (ADF&G 1983b: Appendix C, D; Vincent -Lang et al. 1984). This characteristic of chum salmon has also been reported in other areas ' (e.g., Kogl 1955; Lister et al, 1980) indicating that upwelling is a favorable environmental factor affecting the survival and development of 1 embryos. The importance Of upwelling to incubating embryos is due to ' severa) reasons: 107 DRAFT 2111/85 1] it reduces the likelihood of dewatering and freezing; 2] it provides a relatively stable incubation environment (especia?ly temperature) for developing embryos less affected by variations in local climatic conditions; end 3) it increases the rate of exchange of water over the developing embryos which would enhance replenishment of dissolved oxygen and removal of metabolic wastes. Owelling and surface water are the two primary sources which contribute water to the intragravel environment (McNeil 19551. The extent to which each source contrioutes to the intragravel water at the location of a particular redd depands upon a variety of other factors, which in the Susitna River are poorly understood. Interchange between the surface and intragravel water is highly vari- able, depending on the turbulence of water in the stream ano physical characteristics of the streambed (Vaux 1968). Factors which enhance high levels of dissolved oxygen in intragravel environments include high streamflow, high streambed gradiert, uneven streambed surface and coarse bed material (McNeil 1969). In addition to these factors, the composi- tion of the substrate also affects the rate of exchange of water to incubating embryos based on the permeability of the substrate (Pollard 1955). RUP GRAFT 211U85 In general, slough habitats in the middle S°usitna River are affected by upwelling to a greater extent than are other habitat types. UpwelIing areas are also evident in side channel, tributary, and mainstem habitats, but to a lesser and more variable extent. As a ' result, the beneficial effects of reduced dewatering and freezing of substrate, relatively stable intragravel temperatures and increased ' intragravel flow is afforded to slough habitats over other habitat types. ' I4.1.2 Dewatering and Freezir,. Freezing of artificial redds associated with surface dewatering was determined to be the most important factor contributing to the high 1 mortality of chum salmon embryos in this study. Because it was observed ' that the substrate in the streaffbed of almost all dewatered surface areas of sloughs could soon freeze in sloughs lacking an upwelling water source, the effects of surface dewatering in areas lacking upwelling were considered synorymoui with the freezing of substrate in this study. The potent;al effects of surface dewatering and associated freezing conditions of substrate are included here because it is likely that the influence of dewatering and freezing of habitat without an upwelling water source may be of greater significance under post -project conditions if mainstem river stage fluctuates appreciably in response to power demands. Surface water fluctuations which affect the presence or absence and rate of upwelling will also be of significance. Dewatering of the 109 DRAFT 2/11/85 intragravel water environment of a salmon redd results in significant changes in the incubation environment within which embryos devel3p (Reiser and White 1981a, b; Neitzel and Becker 1983; Neitzel et al. 1984). Two primary effects of these changes are the direct exposure of the embryos to desiccation of respiratory structures and to increased temperature fluctuations, especially freezing (Neitzel and Becker 1983). The effects of desiccation on embryo survival varies with the stage of embryonic development (Becker et al. 1982). Experimental studies indicate that incubating embryos are more tolerant of dewatering than alevins primarily because of the differences in their respective means of respiration (Neitzel and Becker 1983). Alevin respiration involves delicate gill structures that cannot function without a water medium; whereas, respiration of pre -hatched embryos involves a transfer of oxygen across the egg membrane, requiring only that the membrane remain moist. The deleterious effects of temperature fluctuations, especially freezing, to embryos resulting from dewatered salmon redds in the midcle Susitna River involve cold and/or freezing temperatures during the ice covered season. Cold, but nonfreezing temperature conditions can contribute to embryo mortality in dewatered redds if the condi ti otis occur prior to the embryonic stage when the blastopore closes (this is further discussed in Section 4.1.3). In comparison, freezing temperatures cause embryo mortality regardless of the stage of embryonic: 110 DRAFT 2/11i85 I I P P I I I I development prior to hatching. The ability of alevins to transport themselves through gravels to favorable environments reduces the effects of localized freezing on them relative to unhatched errs ryos. Although the length of time from initial dewatering of an area which is packing upwelling to the time when the substrate was frozen to a depth of 8-10 in. (depth at wn'ich WVBs were placed) is unknown, it undoubtedly depends upon site specific features such as ambient air temperatures, proximity to thermal influences of upwelling, and the depth of the snow cover. T'ne areas which were observed as being t^:: most susceptible to high embryo mortality due to surface dewatering and freezing in this study were those most directly influenced by mainstem stage at :he time when fish were actively spawning (mid August - mid September) and lacking an upwelling water source. These areas include the mouths of both sloughs and tributaries, major portions of side channels, and peripheral areas In the mairstem river. in each of these areas, water levels were significantly higher during the spawning period when fertilized eggs were deposited. However, as the mairstem discharge decreased to winter flows, these areas progressively became dewatered and exposed to freez- ing ambient temperatures. This ultimate.,y resulted in a frozen sub- strate environment and the salmon ertrbryos deposited within the dewatei-ed redds. Areas which are thermally influenced by strong upwelling sources (e.g., rxuth area of Slough 11) or dewatered areas adjacent to areas of flowing water (e.g., Side Charnel 21) were protected from the winter surface dewatering and associited fr7e:.�ir!g conditions. I11 DRAFT 2/11/85 The effects of dewatering and freezing of embryos was clearly evident in the Progression of seasonal events which occurred in Side Channel 21. Forty Whitlock-Vibert Boxes containing chum salmon embryos were initially placed in this side channel at the end of the spawning season in late August. These WVBs were buried approximately 8-10 inches in the substrate and did not include the deeper section (thalweg) of the site. At this time, the mainstem discharge was 27,000 cfs at Gold Creek and this side channel area was ;reached. Approximately two weeks later, the discharge in the mainstem dropped to 11,100 cfs. As a result, the side channel was no longer breached, and the local flow in this side channel was significantly reduced. The majority of the locations lacking an uprre" ing source where WV8s had been implanted two weeks earlier had dewatered. Therefore, twenty additional WVBs were installed in the remaining wetted area of the channel in the same manner as during the high flaws. The flow continued to decrease throughout the winter but the majority of locations at which additional WV8s had been installed during the lower flows refrained wetted. All the embryos in the forty WVBs which were initially installed during the earlier period (August 27) died due to dewatering and freezing whereas, in the latter set of 20 Ms installed after the water level dropped, 11 WV8s contained living embryos at -he time of sampling. This example clearly indicates that the water level at the time when fish are spawning is important in determining the amount of wetted habitat available for spawning, but that the effective area in which embryos survive depends upon ether water levels which occur after the spawning period or the presence and persistence of upwelling. 112 DRAFT 2/11/85 4.1.3 Substrate ' The composition of substrate is of critical importance in determining the survival of embryos to emergence. The substrate provides the ' physical structure with"n which embryos are placed and thus is the medium through which the intragravel water must flow in order to supply ' embryos with necessary oxygen and to transport waste metabolites away from the embryos. These two processes occur simultaneously and are both ' jependent upon a variety of physical factors such as the composition uf ' the substrate, gradient of the streambed, rate of exchange between surface and intragravel water, relative importance of upwelling, depth ' and permeability of the gravel, and the configuration of the surface of the streambed (Yaux 1952). Although each of these factors may influence the rate of intragravel flow to various degrees, the composition of the substrate has receivers the most attention by researchers. In general, researchers agree that the amount of fine substrate particles in the spawning gravels is a primary factor affecting mortality of embryos and alevins. High levels of fines reduce the intragravel flow which may result in oxygen deprivatior and toxic build-up of waste metabolites.. However, despite the general consensus that "large" amounts of 'fine sediments" are detrimental to survival of salmon embryos, there is much variation in the literature in defining what constitutes "large" amounts and what particle sizes should be regarded as "fines". Table 4 presents a summary of these literature on this topic. 113 m r-AAF'F � F u `�i� .�r� L� .y it ssr.;iY Yam•.. iM.wir:� :435 ]]7 VI 2 Ili I 04� -� • �..+ i . 1 ii 1 i �_� r r is i .-. •y`h: r■ r r : r w . r ;:�:+: r -� T.: a i. r P - e yy gyp■ } "3a�"2 Nr� a�a v: OU-11 a2 f � r 4 ip ■ V i A r y � 'S ^ �o p v s rn S.� to N 3� F fi i v 114 | � k � ; � § � - �f� ■|} } 2 -_- t� ■ �- ��! � !E !y -- ■ �� ■ � � � - v } } = 7 f � | � | ! � � § } ! | � � }�) ■ I\ • ■ } -|� ■ }) \�\ } ;I!| ■�� ! � f� I }�. ��■ � �■ |� �� �� �)� §� ' k . \ \ � ■ ( � ■ - �2 7 ■ �■ . �� % ��� ` } �■! � ■ ! i{I ! - \ � ) f � § ! ! } � � CRAPT DRAFT 2/11/85 In addition to restricting intragravel flow of water, large amounts of fines also restrict fry from emerging from the substrate (e.g., Dill and Northcote 1970a). Fine substrate reduces the interstitial spaces between larger substrate particles. This results in entrapment of emerging fry, especially large fry (wells and McNeil '970). The composition of substrate varies extensively between habitat types In the middle Susitna River. This characteristic fs evident in the preparation of fines reported for McNeil samples collected in each habitat type (refer to Figure 27). Based on rh- smell number of samples collected, slough haoitats contained more than twice the percent of fines as tributary and mainstem habitats (Figure 27). Side channel habitat contained intermediate amounts of fines. However, spawning salmon within each habitat type apparently succeed in selecting redd locations with substantially less fines. for example, even though slough habitats contained more than 35% fines for combined slough satples (Figure 27), the percent of fines present in chum salmon redds obtained at various sites did not exceed 16% (refer to Figure 30) in r five of the six sites evaluated. (Samples from the mainstem site were i not obtained at redds). Substrate data obtained with Whitlock-Vibert Boxes revealed similar results. With the exception of four outliar points, the data represented in Figure 52 indicate that embryo survivai approaches zero when fines exceed 16%. Thus, based on data obtained in this study, it appears that chum salmon typically select redd locations in areas containing less than 14% fines (C 0.08 in. diameter). 116 ' DRAFT 2/11/85 Of the four habitats evaluated, the greatest risk for adverse effects involving substrate/dissolved oxygen interactions exist for slough ' habitats. Slough habitats are used extensively by chum and pink salmon for spawning; yet, they contain the highest levels of fine substrates ' and lowest levels of intragrave] dissolved oxygen. This apparent contradiction is best explained in terms of the ameliorating effects of ' the upwelling systems which apparently maintain an adequate flow of ' water through the gravels even though the DO levels are relatively low. In addition, as stated previously, the upwelling water prevents the ' substrate materials from dewatering and freeing. Thus, it appears that the single most important feature which maintains the integrity of the ' incubation habitat in sloughs (and localized areas in side channel and mainstem habitats) is upwellin;. If there is an alteration in the ' quality or quantity of water supplied to sloughs via the upwelling system, it will undoubtedly result in alterations in the quality of the habitat for incubation of chum salmon embryos. In particular, if the quantity of water is reduced, the rate of exchange of intragrave] DO may also be reduced. 1 4.1.4 Water Temperature Two primary effects of water temperature on the development and/or survival of salmon embryos involve the effect of temperature on the rate of embryo metabolism and the effect of temperature as a stress factor. The water temperature of the intragrave) environment in which embryos are incubated is a primary determinant of the rate of basic embryonic 117 DRAFT 2/11/85 metabolism within the tolerance limits of a given species of fish. A rise in temperature will -esult in a corresponding rise in metaboiic rate. This development is more rapid at higher temperatures. However, the ecological effects of an altered rat: of development is varied. For example, if the average daily intragravel water temperature is increased in mainstem-affected habitats as a result of construction or operatiol. of the proposed Susitira dams, it would undoubtedly result in a corresponding increase in the rate of development of incubating embryos in these habitats. Another direct effect of water temperature is its role as a stress factor. Thermal stress resulting from excessively high or sow tempera- tures may result in increased mortality of embryos. These effects are most pronounced in salmon during the period of development before the closing of the blastopore (Combs 1965; Bams 1967; Velsen 1980). For chum and sockeye salmon from the middle Susitna River, 3.4°C was reported as the temperature below which mortalities were observed to increase (Wangaard and Burger 1983). [In chum salmon, blastopore closure is complete when embryos have accumulated approximately 140 thermal units (TUs) (Combs 1955)]. For pink salmon, Bailey and Evans (1971) defined a lower threshold temperature of 4.5°C (Table 5). Below this temperature, mortality of embryos is increased. In addition to dewatering and freezing of salmon embryos, thermal stress in incubating habitats in the middle Susitna River is likely to result from the occurrence of "overtopping" or "breaching" of the upstream end 118 DRAFT 2/ 11/85 Table 5. Observed temperature ranges for embryo/alevin life Stages of Pacific salmon [(table derived from AEIDC (1984)]. Incubation Species Reference location Temperatures (°C)a Chum McNeil (1966) Southeast Alaska 0-15.0 Merritt & Raymond (1982) Noatak River, Alaska 0.2-9.0 Sano (1966) Japan 4 McNeil & Bailey (1975) Southeast Alaska 4.4 Kogl (1965) Chena River, Alaska 0.5-4.5 ' Francisco (1977) Delta River, Alaska 0.4-6.7 Raymond 0-981) Clear, Alaska 2.0-4.5 ADF&G (1983c) Sus�tna River, Alaska 0-7.4 Wangaard & Burger (1983) Laboratory 0.5-8.0 Pink Bell (1973) 4.4-13.3 Bailey & Evans (1971) Southeast Alaska 4.5 Combs & Burrows (1957) Laboratory 0.5-5.5 McNeil et al. (1964) Southeast Alaska 1.0-8.0 1 Godin (1980) Laboratory 3.4-15.0 Sockeye Bell (1973) 4.4-13.3 Combs (1965) Laboratory 4.5-14.3, 1.5b ADF&G (1983c) Susitna River, Alaska 2.9-7.4 waangard & Burger (1983) Laboratory 2.0-6.5 Chinook Bell (1973) 5.0-18.4 Combs (1965 ) Laboratory 1.5 Alderdice & Velsen (1978) 2.5-16.0 Coho Bell (1973) 4.4-13.3 McMahon (1983) 4-14, 4-10c a Single: temperature values are lower observed thresholds. b After eggs had developed to the 128-cell or early blastula stage at 5.5°C. c Optimum range. 119 DRAFT 2/ 11/85 of slough and side channel habitats with cold water from the mainstem. The inundation of these habitats with water from the mainstem Susitna River will undoubtedly result ipi a rapid and significant reduction in the itragravel water temperature. Such an event would alter the timing of developmental processes and could be lethal to embryos if overtopping occurred before embryos have developed past the point of blastopore closure. Thus, the deleterious effects of overtopping will be greater during the early weeks of the incubation period. For example, if chum salmon eggt were fertilized on September 1, and are incubated at 4°C, closure of the blastopore would occur during the first week of October (approximately 35 days later). If overtopping occurred after the first week of October, and affected the temperature of intragravel water of a redd site, the likelihood of mortality due to thermal stress would be greatly reduced. Temperature may also affect embryos indirectly through its influence on other variables such as dissolved oxygen. In addition to increasing the metabolic demand for oxygen by embryos, an increase in temperature reduces the saturation level of oxygen in water. Thus, there is less oxygen available and the demand is greater. Since oxygen concentrations can also affect a large variety of developmental factors (see Section 4.1.5) this relationship to water temperature could be critical, partic- ularly in areas where dissolved ❑xyger: values are near threshold levels. If incubation temperatures are higher, the increased metabolic demand for dissolved oxygen may result in higher embryonic mortality in Sub- optimal habitat where the intragravel flow of water is restricted. This 120 i I ■ I DRAFT 2/11/85 effect would be expected to be greatest in incubation habitats contain- ing relatively large amounts of fine particles and also in areas lacking upwelling. Such areas include the mouth areas of slough, side channel and tributary habitats. The seasonal pattern of variation of intragravel water temperature varies distinctly between habitat types in t`ie middle Susitna River. Differences appear to be linked to the relativ,% importance and source of the upwelling water systeik, supply in eac;? habi-,:at type. Areas heavily influenced by upwelling water which exhioit a high degree of thermal stability are buffered from the hazards of surface dewatering and freezing (previously discussed). sloughs such as 10, 11, and 2: fit this pattern. Salmon embryos incubating in these areas accumulate TUs at a relatively uniform rate. In contrast, the intragravel thermal regime of tributary habitats and probably most of the mainstem habitats is influenced primarily by surface water. In these habitats, the seasonal variation in intragravel f temperatures is much greater. Tributaries typically have relatively high intragravel water temperatures during the fall when spawning occurs. These intragravel temperatures seem to be nearly identical to the surface water temperatures which decline sharply in late October to near freezing levels. Temperatures remain near freezing levels until warming spring waters cause a sharp rise in temperature. The pattern of accumulation of TUs for developing embryos is thus. very Nuc h dependent upon the time when spawning occurs and the ambient temperatures which control the surface and intragravel water temperatures. 121 DRAFT 2111,18E In early September, during the chum salmon spawning season, temperatures in Fourth of July Creek were nearly VC (refer to Figure 20). However, by early October, intragravel water temperatures dropped to less thar; 2°C. Temperatures in this range may result in mortality of embryos i--- blastopore is not completed. This pattern of rapid decrease in water temperature during September may account for the observed differences in the timing of the arrival of chum salmon which spawn in slough and tributary habitats. Although the difference in time of arrival is not large, it appears that fish which spawn in tributaries arrive earlier than fish which spawn in sloughs. The thermal regime in the mainstem is similar in pattern to tnat of a tributary. However, the water temperatures in fall and spring are M)t as high. As a result, this habitat type is not used extensively Ay spawning chum, presumably because they cannot acquire an adequate numii!r cf TUs to complete their development. Areas in the mainstem which are presently used by chum salmon fcr spawning appear to be restricted to areas where upwelling occurs. Presumably these areas afford a more favorable thermal regimi and enable development to be completed. An increase in the wate- temperature in this habitat type may be beneficial to the incubation of chum salmon in that a greater amount of habitat may be thermally suitable for completing development. This increase in area is likely to he closely linked to areas of upwelling. 122 DRAFT 2111/85 Side channel habitats are characterized by a high degree of thermal Evariability. They typically --indergo extensive dewatering, which is generally followed by the freezing of the substrate. The primary areas which penvide suitable habitat for spawning chum salmon are relatively small, localised areas of upwelling (e.g., areas in Side Channel 10), end the relatively narrow, unfrozen channel which flows throughout the winter (e.g., Side Channel 21). In general, this habitat type provides poor incubation conditions. 1 4.1.5 Dissolved Oxygen Although researchers generally agree that Tow concentrations of dissolved oxygen (00) result in deleterious effects in the development and the survival of salmon embryos, there is considerable question as to the precise level of 00 which may be considered harmful. A summary of documented effects of low dissolved oxygen on incubating salmon embryos is presented in Table 5. Numerous studies have shown that low, but non -lethal concentratiens of h0 may result in a decrease in the rate of embryonic development (Garside 1959), an abnormal progression of tissue differentiation (Hayes 1949), a reduction in size of alevins at hatching (Silver et al. 1963; Shumway et al. 1954), premature hatching (Alderdice et al. 1958), and increased mortality (Wickett 1954, 1958; Alderdice et a.. 1958; Coble 1961; Phillips and Campbell 1951; McNeiT 1962; Koski 1975) . 123 ORAFT 2/11/85 Consumption of dissolved oxygen by salmon embryos progressively increases from the time of fertilization to hatching, with lower threshold levels ranging from 1.0 - 7.0 mg/l, respectively (Alderdice et al. 1958). There are two stages of embryonic development which are particularly sensitive to DO levels. These include the period just prior to the development of a functional circulatory system [approxi- mately 2OU Thermal Units (TUs) for chum salmon] and the period just prior to hatching (Alderdice et al. 1958) . Of these two periods, the latter appears to be most sensitive to low dissolved oxygen levels. The reasons for increased sensitivity Zo low DO levels during these two periods is related to the physiology and the tinning of development of the circulatory system in relation to changes in the biological demand for oxygen in developing tissues. During the first of the two sensitive periods, DU consumption for basal metabolism is lower and embryos possess a physiological plasticity which enables them to compensate for hypoxiai conditions by delaying develop- ment. This compensatory ability, however, is apparently lost after embryos have acquired 200 TUs and developed a functional circulatory system (Alderdice et al. 1958). Thus, the increased sensitivity of the second sensitive period (just before hatching) results primarily from its relatively higher DO requirement for basal metabolism compounded by the loss of ability to compensate for increased DO consumption by delaying embryonic development (Alderdice et al. 1958). The respiratory exchange at the surface of pre -hatched fish embryos is influenced by the processes of diffusion and convection (Daykin 1965; 124 DRAFT 2/11/85 O'Brien et al. 1978). As the respiring embryo acts as an oxygen sink by removing DO from the diffusion layer surrounding the outer surface of the egg capsule, oxygen is replenished to the diffusion layer via convection (O'Brien et al. 1978). In turn, the rate of replenishment of ' DO to tb2 surface of the egg capsule membrane is influenced by a variety of c-,her environmental factors, including the concentration of DO in the intragravei water, the gradient of the stream surface profile, per- meability of the gravel, and interchange of oxygenated surface water. 1 Both the concentration and the rate of exchange of dissolved oxygen are important characteristics which determine the suitability of the habitat for successful incubation of salmon (Coble 1961). However, recommended levels for both criteria differ. For example, McNeil and Bailey 1,1975j recommend threshold D4 levels of 6.0 ng/l whereas Reiser and Bjornn (1979) recommend 5,0 mg/I. Similarly, the recommended rate of intragravel flow proposed by Reiser and Bjornn was 20 cm/h whereas Bell (1973) recommends a rate of 110 cm/h. It is likely that these differences in estimates arise from differences in experimental conditions. However, the criteria provided by Reiser and Bjornn seem to be a bit low when compared to the experimental results performed on chum salmon by Alderdice (1958). In these tests, 7.19 mall 00 at an intragravel flow rate o•r 85 cm/h was established as the critical oxygen level, below which the respiratory demand would not be adequately met (refer to Taole 6). These threshold criteria were developed for embryos nearly ready to hatch (452 TUs) and thus are estimates at trie time when the demand for dissolved oxygen is greatest. 125 CRAF ' ■ ail M �I t ■r �r ��w � �w � Jy �r ��'.r y,w Nr Yyy {}�� yy yam' y y�L tyy a i i � � �■ j� ■ Y " 22 Y � 950 M � � + 4 Y • • �� • � � Y • y s10;�: tea ! w rr ��■■ r�■ s a e u a i i o .r .� n �wN w..ww wW*.i w r 01 R i i i l RM .~` . ■ is lot ;A 6.3 �� �� a— Ca A 2-4 ,. ■ ,. • ; • 126 � � . | �k � � � �- | a� | " }a � � !! � ■� �I � } | - } � ! ! � !- ��£ tH;$ �- }�;- 04 !@ § � � Iwo,: 2 - l�=s,■�.=� ■ � M:xj sI®� ■|_; 2v ! sl f- ! . � 3 sr ! !■ .� � ■� ■■ }2 a $ .■�a a a | � a CRW � % 2 ! f � | 2 ■ � . -- �- ( } ! all ON \ J \ J DRAFT 2/11/85 To a large extent, the concentration of DO in the intragravel environment is a result of the concentration of OD in surface and sources and their relative contribution of these two sources to the intragravel water supply. In the middle 5usitna River, the relative contribution of these two sources of water varies between two extremes. In general, upweliing apparently dominates as the primary intragravel water supply of slough habitats whereas surface water dominates in tributary habitats (mainstem and side channel habitats seem to vary between these two extremes). In general, the concentration of dissolved oxygen (DO) in intragravel water was consistently lower than surface water concentrations in each habitat evaluated. However, the difference between intragravel and suirf4re water 00 levels was greatest for slough habitat and least for tributary a,.- mainstem habitats. Differences were intermediate in side channel habitats. Thus, with the possible exception of sloughs, the DO levels in most of the incubation habitat evaluated appear to be ahcve the recommended levels of 7.19 mg11 established by Alderdice (1958). However, in sloughs, the potentially adverse effects of lower 00 levels are undoubtedly ameliorated by the possible influence of in providing a relatively consistent intragravel flow. In turn, the rate of intragravel flow is intimately related to the permeability of the substrate and is therefore discussed more fully in section 4.1.3. 128 I DRAiT 2/11/85 4.1.6 pH R r-elatively broad range of pH values are considered acceptable for successful incubation of salmon embryos. Leitritz and Lewis (1976) report that values between 6.7 and 8.2 are acceptable, and that values outside this range should be regarded with suspicion. The authors note, however, that this range of values does not account f=jr varying degrees of sensitivity to pH between species and/or species life -phases. Rombough (1982) evaluated the ;ensitivity of pacific salmon Prrrbryos to low pH levels (3.5 to 6.0) and found that sensitivity to pH varied with species and developmental stage. He compared the sensitivity of each species at three specific developments" stages (Eyed embryos, newly hatched alevins, and buttoned -up alevins), and found that the sensi- tivity to low pH levels increased for each species with increasing stage of deveTopment, but that the relative sensitivity of each species varied depending on developmental stages. For example, chum and pink salmon were the most sensitive during the eyed and buttoned -up alevin stages, but were Tess sensitive than Soho, chinook or sockeye salmon during the stage of nearly hatched alevins. In each of the three developmental stages tested, pH levels were be'ow 6.0. However, Rombough (1982) also reported that he observed aberrant behavior in buttoned -up alevins of pink and chum salmon at pH levels of 6.0-6.1. Levels of pH in the 6.0 to 6.5 range are nct typical of habitats in the mainstem of the middle Susitna River. Natural pH levels in the mainstem 129 DRAFT 2/11/85 Susitna River typically vary between 7 and 3 during the winter, occasionally dropping below 7 (Exhibit E). However, adjacent slough, side channel, and tributary habitats generally have lower pH values, often ranging below 7, with occasional values below 5.5. In this study, low survival rates occurred with low pH values, indicating that pH may have an effect on embryo survival at lower pH values. In the spring, a drop in the pH levels in the mainstem river coincides with increased runoff from the Susitna Basin (Acres 1982). This phenomenon is cotrnron to Alaskan streams where tundra runoff is typically acidic. If mainstem flows in the Susitna River are r:duced during the spring runoff period during project operations, a relatively greater proportion of the flow in the mainstem will originate from acidic tundra runoff. This relationship is likely to result in pH values which are lower than present and historical values. The effect of lowered pH values in the rruinstem may be indirectly harmful to embryos or pre -emergent fry, depending upon the levels of other variables. For example, Bell (1973) reports that low levels of pH affect the tolerance of fish to low concentrations of dissolved oxygen rnd that the sensitivity of fish to toxic levels of socdium sulfide, cyanide, ammonia, and various metallic salts increases with decreases in PH. Also, the synergistic effects of two c.r more elements (particularly metallic ions) may have adverse effects at much lower levels than either one individually (Bell 1973). Thus, the effects of lowered pH values cannot be evaluated independently, but must be considered in concert 130 I DRAFT 2/11/85 1 with anticipated changes in the overall ionic composition of the water ' in each habitat where embryos ire present. 4.1.7 Conductivity Conductivity is a measure of the capacity of water to conduct an elec- tric current. As such, it is an indication of the total concentration of dissolved ionic matter in the water and is also directly related ' with both water hardness and alkalinity (Lind 1974). However, this variable is not of direct consequence to fish, but rather is a general water quality indicator which is intricately related to the variables above. Below Devil Canyon, winter conductivity values in the mainstem river ' range from 160-300 umhos (micro -mhos) while corresponding values of total hardness and total alkalinity range from 60-120 mg/l and 45-145 mg/l, respectively (Acres 1982). These values are at the lower ent: of the suggested "optimal range" for fish (120-400 n:g/l) prcvided by Piper et al. (1982). This is significant, because at very low alkalinities, water loses its ability to buffer against changes in acidity and may result in wide fluctuations in pH values which in turn may be detri- mental to fish. In this study, however, there does not appear to be any relationship between observed conductivity values and embryo survival (Figure 54). 131 DRAFT 2111/85 4.1.8 Turbidity The specific effects of various turbidity levels on the incubation life -phase of salmon in the middle Susitna River are presently unknown. However, excessive turbidity levels can have adverse effects on the incubation life -phase by smothering fish embryos (Piper et al. 1982). This problem is treated as part of a larger problem involving the evaluation of the role of substrate composition on the availability of dissolved oxygen to developing embryos. 4.1.9 Flatworms It should be noted that there are many biological variables which could potentially affect the development and survival of incubating salmon embryos. Among these are effects due to vertebrate egg predators such as sculpins, and invertebrate egg predators such as caddisfly and stonefly larvae. In addition, loss or death of embryos can occur due to bacterial, viral, protozoan, or fungal agents. This section is limited to a discussion on flatworms which appeared to be associated with a decrease in salmon eggs at some study sites. Evaluation of other biological variables was outside the scope of this study and they are not discussed in this report. Relatively large numbers of embryos were discovered to be missing from Whitlock-Vibert Boxes at the time of removal. Missing embryos were assumed dead for the purposes of this study; but the actual case of their disappearance remains undetermined. Be -cause relatively large 132 I DRAFT 2/11/85 I I 1 1 1 I 1 7 1 1 1 I 1 1 I 1 I numbers of flatworms were present in WVBs in which embryos were missing, it was suspected that they were scavenging cn dead embryos. A simple experiment conducted to establish the rate of scavenging by f1atwo rms was not conclusive, but indicated that it required more than a two month period. The role of planarians in the removal of embryos from Vibert Boxes was previously investigated by Heard (1978) in a stream in southeast Alaska. After conducting rests with various combinations of planarians and live and dead salmon eggs and alevins, he colicluded that. the test planarians did not prey on and were not toxic to live embryos, and did not feed on dead eggs unless the chorion was broken and egg contents exposed. Based on the results of the experiment conducted in this study and the conclusions presented by Heard (1978), the following hypothesis is proposed as a plausible explanation for the disappearance of embryos. The most familiar type of feeding pattern followed by planarians involves the protrusion of a muscular pharynx out through the mouth where soft and disintegrating animal tissues are sucked up into the gastrovascular cavity (Penr.ak 1978). Thus, it the egg caps: _ is intact, it is likely that planarians are not able to utilize them as a food source. This is consistent with Heard's conclusion that planarians did not feed on dead eggs unless the chorion was broken or egg contents exposed. Additional evidence from the experiment conducted in this study suggests that culonization of dead eggs with fungi may be a necessary "con- ditioning process" which must occur before planarians can successfully 1 133 DRAFT 21i1J83 scavenge dead eggs. Presumably, the fungal hyphae penetrate the egg capsule and cause the egg to "break apart_" After this occurs, the egg contents would be exposed and suitable for successful scavenging by planarians. Altho)sgh the initial "processing" of the egg capsule by fungi appears to require at least two months, it is suspected that complete removal of the egg contents by planarians would be a much more rapid process in areas where planarian densities are high. 4.2 Concl us l ons/Recormiendati ons 4.2.1 Conclusions 1. Denatering and freezing of salmon redds were identified as the most important factors contributing to the high levels of embryo mortality found in habitats used for chum salmon incubation in the middle 5usitna River, In general, these factors were most pronounced in side channel habitats and least pronounced in slough habitats which were protected from cold surface water overtopping and where upweTling was more prevalent. 2. Upwelling was the most significant environmental factor affecting the development and survival of salmon embryos incubating in slough, side channel and some mainstem habitats of the middle 5usitna +iver. The importance of upwelling to incubating embryos is due to the following reasons: 134 DRAFT 2/ 11/85 a) it eliminates or reduces the likelihood of dewatering or freezing of the substrate Environment from occurring; b} It provides a relatively stable intragravel incubation environment, buffering it frorr, variations in local surface water and climatic condit'ons; and, c} It Increases the rate of exchange of intragravel water over the embryos which enhances the replenishment of dissolved oxygen and the removal of metabolic wastes. 3. The total surface water area of ietted habitat available at the time when adult salmon are spawning is not a good indicator of the success of that area as incubation habitat. The wetted surface area in terms of incubation primarily depends upon the relationship of wetted surface area to the availability of wetted intragravel environments occurring after the spawning period, 4. the pattern of accumulation of thermal units for developing salmon embryos varies between spawning habitat types for the middle Susitna River. A general thermal regime describing the incubation period for each habitat type can be stated as follows: 135 DRAFT 2/11/85 a) Tributary habitats typically have intragravel water temperatures which are strongly influenced by surface water temperatures. This results ir, high intragravel water temperatures during the fall and spring months with near freezing water temperatures (0.0 to 8.0'C) during :he intervening winter months; bj Slough habitats generally have stable, relatively high, intragravel water temperatures (0.0 to 6.9°C) throughout the inclbation period due to the influence of suitable upwelling sources; c) Mainstem habitats typically have winter intragravel water temperatures (0.1 to 0.9°C) which are strongly influenced by surface water temperatures, similar to tributary habitats except for colder water temperatures during the fall and spring periods; and, d) In general, winter intragravel water temperatures (0.0 to 12.5°C) in side channel habitats dre quite variable and may reflect any of the patterns exhibited by the other habitat types depending upon the relative influences of and relationships between upwelling and surface water 50L'rces. 5. Significant mortalities of salmon embryos due to thermal stress are anticipated if altered flows increase the incidence 136 DRAFT 2111/85 of cold mainstem water overtopping slough and side channel habitats having insufficient supplies of warmer upwelling or local surface waters in the middle Susitna River during fall and winter. If post -project mainstem water temperatures are warmer than existing winter temperatures, this thermal problem associated with overtopping will be aR*1 iorated. 6. In general, slough habitats of the middle Susitna River contain greater amounts of fine sub trate (38%) compared to 1 side channel, tributary and mainstem habitats (19%', 13%, 120,r respectively). 7. Areas w;,ere salmon established redds in each habitat type contained fewer fines than the range of substrate materials available in each habitat type of the middle Susitna River. 8. with the exception of slough habitat, dissolved oxygen (DO) levels in most incubation habitats of the middle Susitna River during the winter period are generally above the recommended levels of 7.19 mg/l established by Alderdice (1953). Although DO levels in intragrave7 water of slough habitat are generally lower (0.4 to 12.3 mg/l), the potential adverse effects of low DO are undoubtedly ameliorated by the influence of r�pwelling, depending noon site specific conditions. 9. The pH levels present in incubation habitats of the middle Susitna River (6.2 to 8.3) are within the lower range of 137 i DRAFT 2/11/85 acceptable limits but do not appear to be detrimental to embryo survival and development. However, the indirect effects of low pH levels interacting with other water quality parameters may result in unpredictable side effects. 10. Conductivity values in incubation habitats of the middle Susitna River (24 to 283 umhos) are within acceptable limits and do not appear to have any direct adverse effects en incubation embryos. 11 The relationship between sediment composition, flushing flows (Estes 1985), and mechanical ice processes are unknown in these habitats, but may become a significant factor for successful incubation under post -project conditions. 4.2.2 Recommendations The results of this study have provided some preliminary conclusions describing the environmental conditions affecting the incubation life - phase of chum salmon in the middle Susitna River. The recommendations outlined below are designed to strengthen and expand these conclusions. One area requiring additional investigation is an evaluation of the "effective spawning" area. Milhous (1982) aefines this concept as the spawning area that does not oewater during the following incubation period. Previous studies have developed weighted useable area curves 138 DRAFT 2/11/85 describing the spawning habitat area available for both pre -project and ' post -project conditions on the middle 5usitna River. However, spawning 1 habitats will not produce salmon fry if the intragravel environment becomes dewatered during the incubation period. Consequently, the ' survival of salmon embryos in spawning areas must be evaluated bated on the incubation flows during the winter months. With the present 1 understanding of the deleterious effects of freezing on dewatered spawning habitat, the need to fully evaluate the effective spawning area becomes more apparent. 1 In add;tion to evaluating the effective spawning area, the effect ❑f ' "power peaking" on incubating salmon ernbryos in the middle Susitna River requires investigation. The concept of power peaking refers to the change in stage of mainstem flows throughout the winte- as a function ❑f energy demand during project operations. Of particular interest, is the extent to which the proposed winter flows will water/dewater incubating fembryos bases on fluctuating flows from power peaking. Since the results of this study indicate that dewatered areas invariably freeze, power peaking effects may increase the proportion ❑f embryo mortalities caused by freezing. InsufFicient data are available t❑ project the influence of mainstem discharge on sources of local flow such as upwelling durinn unbreached conditions. This information will be required to refine these analyses ` and is essential for evaluating the impacts of proposed past -project C temperature and flow scenarios and mitigation options designed to compensate for impacts. 139 DRAFT 2/11/85 5.0 CONTRIBUTORS Aquatic Habitat and Instream Flow Studies (AH) Project Leader and Principal Contact Data Processing Project Leader Graphics Typing Staff Editors Data Collection Data Analysis Text Christopher Estes Allen Bingham Carol Hepler Peggy Skeers Joseph Sautner Doug Vincent -Lang Christopher Estes Jeff Blakely Christopher Estes Andy Hoffmann Theresa Keklak Carol Kerkvliet Isaac Queral Craig Richards Sheryl Salasky Gene Sandone Don Seagren Kathy Sheehan Rick Sinnot Kim Sylvester Len Vining Tommy Withrow Allen Bingham Alice Freeman Len Vining Kathrin Zosel Len Vining Jeff Blakely Glenn Freeman 140 DRAFT 2/1.1/85 1 6.0 ACKNOWLEDGEMENTS Special appreciation is extended to the following people for their contributions to this study. 1 -- D. Reiser, Bechtel Corporation, and R. White. Montana State University, for their valuable technical advice on matters involving the use of Whitlock-Vibert Boxes and options for measuring variables of the intragravel environment. -- R. bberuaga, U.S. Forest Service, Thorne Say Ranger District, iTongass National Forest, for his advice ami information regarding the use of the McNeil substrate sampler. 1 -- State of Alaska, Department of Traospartation, for assistance in analyzing substrate samples at their laboratory facility. Funding for this study was provided by the State of Alaska, Alaska Rower Authority. T}RAFT 2/ 11/85 7.0 LITERATURE CITED Acres American, Inc. 1982. Susitna hydroelectric: project: FERC license application. Exhibit E, Volume 1, Chapter 2. Prepared for Alaska Power Authority, Alaska Department of Commerce and Economic Develop- ment. Buffalo, New York, USA. Alaska Department of Fish and Game (ADF&G). 1983a. Susitna Hydro aquatic studies phase II basic data report. Volume 4 (1 of 3: Parts I and fI). Aquatic habitat and instream flow studies, 1982. Alaska Department of Fish and Game Susitna Hydro Aquatic Studies. Anchorage, Alaska, USA. . 1983h. Susitna Hydro aquatic studies phase II report. Synopsis of the 1982 aquatic studies and analysis of fish and habitat relationships (2 of 2: Appendices A-K). Alaska Department of Fish and Game Susitna Hydro Aquatic Studies. Anchorage, Alaska, USA. 1983c. Susitna Hydro aquatic studies phase II data report. Winter aquatic studies (October 1982 - May 1983). Alaska Department of Fish and Game Susitna Hydro Aquatic Studies. Anchorage, Alaska, USA. 1984. Susitna Hydro aquatic studies kMay 1983 - June 1984) procedures manual (1 of 2). Alaska Department of Fish and Game Susitna Hydro Aquatic Studies. Anchorage, Alaska, USA. 142 I DRAFT 2/11/85 1 Alderdice, p.F., and F.P.J. Velsen. 1978. Relation between temperature ' and incubation time for eggs of Chinook salmon (Cncorhvnchus tshawytscha). Journal of the Fisheries Research Board of Canada 35:69-75. 1 Alderdice, D.F., W.P. Wickett, and J.R. Brett. 1958. Some effects of ' temporary expasure to low dissolved oxygen levels on Pacific salmon eggs. Journal of the Fisheries Research Board of Canada 15:229-250. ' Arctic Environmental Information and Data Center (AEIDC). 1984. Assessment of the effects of the proposed Susitna hydroelectric project on instream temperature and fishery resources in the Watana to Talkeetna reach. Draft Report. Prepared for Harza-Ebasco ' Susitna Joint Venture. Anchorage, Alaska, USA. Bailey, J.E., and C.R. Evans. 197i. The low -temperature threshold for pink salmon eggs in relation to a proposed hydroelectric installation. Fisheries Bulletin 69:587-93. Bams, R.A. 1967. A review of the literature on the effects of changes in temperature regime on developing sockeye salmon eggs and alevins. Journal of the Fisheries Research Board of Canada 949:14-22. Baxter, R.M. and P. Glaude. 1980. Environmental effects of dams and impoundments in Carada: experience and prospects. Canadian Bulletin of Fisheries and Aquati- Sciences 205. 143 DRAFT 2111Ic.5 Becker, C.D., D.R. Neitzel and D.H. Fickeisen. 1982. Effects of dewatering on chinook salmon redds: tolerance of four developmental phases to daily dewaterings. Transactions of the American Fisheries Society 111:624-637. Bell, M.C. 1973. Fisheries handbook of engineering requirements and biological criteria. Fisheries Engineering Research Program, United States Army Corps of Engineers, North Pacific Division, Portland, Oregon, USA. Brannon, E.L. 1965. The influence of physical factors on the development and weight of sockeye salmon embryos and alevins. International Pacific Salmon Fisheries Commission, New Westminster, Canada. Cedencclm, C.J., L.M. Lewis and E.O. Salo. 1981. Cumulative effects of logging road sediment on salmonid populations in the Clearwater River, Jefferson County, Washington. Pages 38-74 in State of Washington Water Research Center, editor. Salmon -spawning gravel: a renewable resource in the Pacific Northwest? Report 39, State of Washington Water Research Center, Washington State university, Pullma, , Washington, USA. Coble, D.W. 1961. Influence of water exchange and dissolved oxygen in redds on survivaI of steelhead trout embryos. Transactions of the American Fisheries Society 90:469-474. 144 ■ DRAFT 2; 11185 ■ Combs, B.U. 1965. Effects of temperature un the development of salmon ■ eggs. Progressive Fish-Culturist 27:134-137. ■ Combs, B.D., and R.E. Burrows. 1957. Threshold temperatures for the ■ normal development of chinook salmon eggs. Progressive Fish- Culturist 19.3-6. ■ i Cooper, A.C. 1965. Th.r effect of transported stream sediments on the survival of sockeye and pink salmon eggs and alevin. international 0 Pacific Salmon Fisheries Commission, Bulletin 18, New Westminster, Canada. Daykin, P.H. 1965. Application of mass transfer theory to the problem of respiration of fish eggs. Journal of the Fisheries Research ■ Board of Canada 22:159-171. 0 Dill, L.M., and T.G. Northcote. 1970a. Effects of some environmental ■ factors on survival, condition, and timing of emergence of chum salmon fry (Oncorhynchus keta). Journal of the Fisheries Research 0 Board of Canada 27:196-201. ■ 1970b. Effects of gravel size, egg depth, and egg density on intragravel movement and emergence of coho salmon (Qncorhynchus kisutch) alevins. Journal of the Fisheries Research Board of Canada 27:1191-1199. ■ ■ 145 DRAFT 2/11/85 Estes, C.C. 1985. Evaluation of methods for recommending instream flows to support spawning by salmon. Master's thesis. Washington State University, Pullman, Washington, USA. Francisco, K. 1977. Second interim report of the Commercia" Fish -"technical Evaluation Study. Joint State/Federal Fish and Wildlife Advisory Team. Special Report Number 9, Anchorage, Alaska, USA. Gangmark, H.A. and R.G. Bakkala. 1958. Plastic standpipe for sampling streambed environment of salmon spawn. United States Fish and Wildlife Service Special Scientific Report Fisheries 261. Garside, E.T. 1959. Some effects of oxygen in relation to temperature on the development of lake trout embryos. Canadian Journal o�- Zoology 37:689-698. Godin, J.G. 1980. Temporal aspects of juvenile pink salmor (Oncorh nchus o� rbuscha) emergence from a simulated gravel redd. Canadian Journal of Zoology 58:735-744. Hall, J.Q., and R.L. Lantz. 1969. Effects of logging on the habitat of coho salmon and cutthroat trout in coastal streams. Oregon Agricul- tural Experiment Station. Pages 355-375 in Symposium on Salmon and Trout in Streams, University of British Columbia, Technical Paper 257Q, Vancouver, Canada. 146 IDRAFT 2/11/85 I Hayes, F.R. 1949. The growth, general chemistry and temperature ' relations of salmonid eggs. Quarterly Review of Biology 24:281-308. 1 Hayes, F.R., I.R. Wilmot, and D.A. Livingstone. 1951. The oxygen ' consumption of the salmon egg in relation to development ano activity. Journal of Experimental Zoology 116:377-395. Heard, W.R. 1978. Probable case of streambed overseeding-1967 pink salmon, Qncorhynchus og rbuscha, spawners and survival of their progeny in Sashin Creek, southeastern Alaska. Fishery Bulletin 76:569-582. Heming, T.A. 1982. Effect of temperature on utilization of yolk by ' chinook salmon (Oncorhyncrlus tshawytscha) eggs and alevins. 1 :anadian Journal of Fisheries and Aquatic Sciences 39:184-190. ' Iwamoto. R.H., E.Q. Salo, M.A. Madej, and R.L. McComas. 1978. Sediment and water quality: a review of the literature including a suggested approach for water quality criteria. Uniteo States Environmental Protection Agency, EPA 910/9-78-048. Kogl, D.R. 1965. Springs and ground -water as factors affecting sun vival of chum salmon spawn in a sub -arctic stream. Master's thesi University of Alaska, Fairbanks, Alaska, USA. LA ��p r� 1 147 DRAFT 2/11/85 Koski, K.V. 1966. The survival of :oho salmon (Oncorhynchus kisutch) from egg deposition to emergence in three Oregon coasta' streams. Master's thesis. Oregon State University, Corvallis, Oregon, USA. 1975. The survival and fitness of two stocks of chum salmon (Oncorhynchus keta) from egg deposition to emergence in a controlled strewn environment at Big Beef Creek. Doctoral dissertation. University of Washington, Seattle, Washington, USA. Leitritx, E., and R.C. Lewis. 1976. Trout and salmon culture (hatchery methods). California Fish and Game, Fish Bulletin 164. University of California, Berkeley, California, USA. Levanidov, Y.Y. 1954. Ways of increasing the reproduction of Amur chum salmon. Translated from Russian. Akademiya Nauk SSSR, Ikhtiologi- cheskaya Komissiye, Trudy Soveschanii 4:120-128. Israel Program for Scientific Translations. United States Department of Commerce, Office of Technical Services PST Catalog Humber 8, Washington, District of Columbia, USA. Lind, O.T. 1974. Handbook of common methods in limnology. The C.V. Mosby Company, St. Louis, Missouri, USA. Lister, D.B., D.E. Marshall, and D.G. Hickey. 1980. Chum salmon survival and production at seven improved groundwater -fed spawning areas. Canadian Manuscript Report of Fisheries and Aquatic Sciences Number 1595. 148 DRAFT ?111!85 Mason, J.C. 1969. Hypoxial stress prior to emergence and competition ' among coho salmon fry. Journal of the Fisheries Research Board of -Canada 26:63-91. 1 ' ,icft hon, T.:'. 1983. Habitat suitability index models: coho salmon. United States Fish and Wildlife Service FWSIOBS-82110.49. McNeil, W.J. 1962. Variations in the dissolved oxygen content of ' intragravel water in four spawning streams of southeastern Alaska. United States Fish and Wildlife Service Special Scientific Report Fisheries 402. McNeil, W.J. 1966. Distribution of spawning pink salmon in Sashin 1 Creek, Southeastern Alaska, and survival of their progeny. united 1 States Fish and wildlife Service Special Scientific Report 538. McNeil, W.J. 1969. Survival of pink and chum salmon eggs and alevins. Pages 101-117 in T.G. Northcote, editor. Symposium of salmon and trout in streams. Universi'y of British Columbia, Vancouver, Canada. McNeil, W.J., and W.H. Ahnell. 1964. Success of pink salmon spawning relative to size of spawning bed materials. United States Fish and i Wildlife Service Special Scientific Report Fisheries 469:1-15. 149 DRAFT 2/11/85 McNeil, W.J., and Bailey, J.E. 1975. Salmon Rancher's Manual. United States National Marine Fisheries Service, Northwest Fisheries Center, Auke Bay Fisheries Laboratory, Processed Report, Auke Bay, Alaska, USA. McNeil, W.J., R.A. wells, and D.C. Brickell. 1964. Disappearance of dead pink salmon eggs and larvae from Sashin Creek, Baranof Island, Alaska. United States Fish and Wildlife Service Special Scientific Report Fisheries 485. Merritt, M.F., and J.A. Raymond. 1982. Early life history of chum salmon in the Noatak River and Kotzebue Sound, Alaska Department of Fish and Game, Juneau, Alaska, USA. Milhous, R.T. 1982. The application of the physical habitat simulation system to natural resources management. united States Fish and Wildlife Service. Prepared for the 1982 Summer Computer Simulation Conference, Denver, Colorado. Fort Collins, Colorado, USA. Morrow, J.E. 1980. The freshwater fishes of Alaska. .Alaska Northwest Publishing Company, Anchcrage, Alaska. Neitzel, D.A., and C.D. Becker. 1983. Effects of dewatering on chinook salmon redds: tolerance of four developmental phases to temperature changes and reduced humidity. Batelle, Pacific Northwest Labora- tory, Richland, Washington, USA. 150 I DRAFT 2/11/85 Neitzel, D.A., C.D. Becker, C.S. Abernathy, D.W. Carlile, and E.W. ILusty. 1984. Laboratory simulations of Chinook salmon redd I dewafaring: an assessment of potential impacts at Vernita Bar. Battelle, Pacific Northwest Laboratories. Prepared for the Public ' Utility District of Grant County, Washington. Richland, Washington, USA. O'Brien., R.N., S. Visaisouk, R. Raine, and D.F. Alderdice. 1978. ' Natural convection: a mechanism for transporting oxygen to incu- bating salmon eggs. Journal of the Fisheries Research Bcard of Canada 35:1316-1321. I Phillips, R.W. 1964. The influence of gravel size on survival to emergence of coho salmon and steelhead trout. In Proceedings of the ' Fifteenth Northwest Fish Culture Conference, Oregon State Univer- sity, Corvallis, Oregon, USA. I Phillips, R.W., and H.J. Campbell. 1961. The embryonic survival of ' coho salmon and steelhead trout as influenced by some environmentai ' conditions in gravel beds. Pages 60-73 in the 14th Annual Report of the Pacific Marine Fisheries Commission. Portland, Oregon, USA. I Phillips, R.W., R.L. Lantz, E.W. Claire, and J.R. Moring. 1975. Some effects of gravel mixtures on emergence of coho salmon and steelhead trout fry. Transactions of the American Fisheries Society 104:461-466. 151 DRAFT 2/11/85 Piper, R.G., I.B. McElwain, L.E. 4rme, J.P. McCraren, L.G. Fowler, and J.R. Leonard. 1982. Fish Hatchery Management. United States 1 Fish and Wildlife Service. �r 1 PIatts, W.S., W.F. Mega han. and G.W. Minsha11 1983. Methods for evaluating stream, riparian and biotic conditions. United States Forest Service General Technical Report INT-138, Ogden Utah, USA. Pollard, R.A. 1955. Measuring seepage through salmon spawning gravel. Journal of the Fisheries Research Board of Canada 12:706-741. Pyper, J. (MS). Physical and biological features of natural and artifi- cial spawning grounds of Fraser River sockeye and pink salmon. International Pacific Salmon Fisheries Cowl scion. R&M Consultants, Inc. (RAM Consultants). 1982. Susitna River mile index: mouth to Susitna Glacier. Alaska Power Authority Susitna Hydroelectric Project. Attachment U, prepared for Acres American, Inc. Anchorage, Alaska, USA. Raymund, J.A. 1981. Incubation of fall chum salmon (Oncorhynchus keta) at Clear Air Force Station, Alaska. Alaska Departivent of Fish and Game, FRET} Division. Juneau, Alaska, USA. Reiser, D.W. 1981. Effects of streamflow reduction, flow fluctuatior and flow cessation on salmonid embryo incubation and fry quality. Doctoral dissertation. University of Idaho, Moscow, Idaho, USA. 152 I DRAFT 2/11/85 1 Reiser, D.W., and T.C. 6jornn. 1979. Influence of forest and rangeland 1 management on anadromous fish habitat in western North America. ' Number 1. Habitat requirements of anadromous salmonids. United States Forest Service General Technical Report PNW-9e. Portland, 1 Oregon, USA. Reiser, D.A., and T.A. Wesche. 1977. Determination of physical and ' hydraulic preferences of brown and brook trout in the selection of spawning locations. Water Resources Research Institute, University of Wyoming, Laramie, Wyoming, USA. ' Reiser, D.W., and R -C. White. 1981a. Influence of streamflow reductions on sslmonid embryo development and fry quality. Idaho ' Water and Energy Resources Research Institute, University of Idaho. Research Technical Completion Report, Project A-058-IDA , Moscow, Idaho, USA. 1 1981b. Effects of flow fluctuations and redd dewatering on ' salmonid embryo development and fry quality. Idaho Water and Energy ' Resources Research Institute, University of Idaho, Moscow, Idaho, USA. 1 hombough, P.J. 1982. Effects of low pH on eyed embryos and alevins of Pacific salmon. Canadian Journal of Fisheries and Aquatic Sciences 40:1575-1582. I 1 153 DRAFT 2/11/85 Rukhlov, F.N. 1969. Materials characterizing the texture of bottom material in the spawning grounds and redds of the pink salmon [Oncorhynchus gorbuscha (Walbaum)] and the autumn chum [Oncorhynchus keta (Walbaum)] on Sakhalin. Problems in Ichthyology 9:635-644. Sano, S. 1966. Salmon of the North Pacific Ocean - Part III. A review of the life history of North Pacific salmon. Chum salmon in the Far East, International North Pacific Fisheries Commission Bulletin 18:41-57. Sautner, J.S., L.J. Vining, and L.A. Rundquist. 1984, An evaluation of passage conditions for adult salmon in sloughs and side channels of the middle Susitna River. Chapter 6 in C.C. Estes and D,S. Vincent - Lang, editors. Aquatic habitat and instream flow investigations (May - October 1983), Alaska Department of Fish and Game Susitna Hydro Studies. Report Humber 3. Prepared for Alaska Power Authori- ty. An&orage, Alaska, USA. Scrivener, J.C., and M.J. Brownlee. 1981, A preliminary analysis of Carnation Creek gravel quality data, 1973-1980. Pages 195-226 in Proceedings of a Conference on Salmon Spawning gravel: A Renewable Resource in the Pacific Northwest. State of Washington water Resourci Research Group. Seattle, Washington, USA. i 154 I DRAFT 2/11/85 I Shumway, 0.L., C.E. Warren, and P. Doudoroff. 1964. Influence of ' oxygen concentration and water movement on the growth of steelhead trout and coho salmon embryos. Transactions of the American Fisheries Society 93:342-356. 1 Silver, S.J. 1960. The influence of water velocity and dissolved oxygen on the development of salmonij embryos. Master's thesis. Oregon State College, Corvallis, nrcgon, USA.. Silver S.J., C.E. Warren, and P. Doudoroff. 1963. Dissolved oxygen requirements of developing steelhead trout and chinook salmon embryos at different water velocities. Transactions of the American Fisheries Society 92:327-343. Smoker, W.W., and C.L. Kerns. 1977. Artificial salmon spawning: a ■ manual. !University of Alaska Sea Grant, Marine Advisory Bulletin 7, ■ Juneau, Alaska, USA. SYSTAT, Inc. (SYSTAT) 1984. The system for statistics. Evanston, Illinois, USA. Tagart, J.Y. 1976. The survival from egg deposition to emergence of coho salmon in the Clearoater River, Jefferson County, Washington, Master's thesis. University of Washington, Seattle, Washington, ' USA. I 11 155 7RAF, 21111$5 Tappet, P.Q., and T.C. Ojornn. 1983. A new method of relating size of spawning gravel to salmonid embryo survival. North American Journal of Fisheries Management 3:123-135. Vaux, W.G. 1962. Interchange of stream and intragravel water in a salmon spawning riffle. United States Fish and Wildlife Service Special Scientific Report Fisheries 405. Vaux, W.G. 1968. Intragravel flow and interchange of water in a streambed. united States Fish and Wildlife Service Fishery Bu;'etin 66:479-489. Velleman, P.F., and Q.C. Hoaglin. 1981. Applications, basics, and computing of exploratory data aralysFs. Ouxbury Press, Boston, Massachusetts, USA. Velsen, F.P.J. 1980. Embryonic development in eggs of sockeye salmon (Oncorhynchus nerka). Canadian Journal of Fisheries and Aquatic Sciences, Special Publication Number 49. Vincent -Lang, Q., A. Hoffmann, R.E. Bingham, C. Estes, Q. Hilliard, C. Stewart, E.W. Trihey, and S. Crumley. 1984. An evaluation of chum and Sockeye salmon spawning habitat in slogghs and side channels of the middle Susitna River. Chapter 7 in C.C. Estes and Q.S. VIncent- Lang, editors. Aquatic habitat and instream flow investigations 156 q DRAFT 2I11!8i (May - October 1983). Alaska Department of Fish and Game Susitna Hydro Studies. Report Nuriber 3. Prepared for Alaska Power Authori- ty. Anchorage, Alaska, USA. 1 Wangaard, D.B., and C.V. Burger. 1983. Effects of various watitr temperature regimes on egg and alevin incubation of Susitne River 11� chum and sockeye salmon. United States Fish and Wildlife Service, National Fishery Research Center, Alaska Field Station, Anchorace, 1 Alaska, USA. Wells, R.A., and W.J. McNeil. 1970. Effect of quality of the spawning bed on growth and development of pink salmon embryos and aleviis. United States Fish and Wildlife Service Special Scientific Report Fisheries 616. Wickett, W.P. 1954. T,ie oxygen supply to salmon eggs in spawning be -Is. Journal of the fisheries Research Board of Canada 11:933-953. !� 1958. Review ❑f certain environmental factors affecting the production of pink and chum salmon. Journal of the Fisheries Research Board of Canada 15:1103-1126. ?i Woodward -Clyde Consultants (Woodward -Clyde). 1984. Susitna hydro- electric project first interim mitigation plan for chum salmon ' spawning habitat in side sloughs of the middle Susitna River. Prepared for Alaska Power Authority. Anchorage, Alaska, USA. e 157