HomeMy WebLinkAboutHydro studies of the slims river yukon pub 1974" J
'\
" _/
)
"'
)
' j
" j
)
ICEFIELD RANGES RESEARCH PROJECT, SCIENTIFIC RESULTS: VOLUME 4
(AMERICAN GEOGRAPHICAL SOCIETY-1974)
Hydrological Studies of the Slims River, Yukon,
June-August 1970
Albert P. Barnett*
ABSTRACT. Hydrological studies were conducted on the Slims River during the summer of 1970. The
purpose was to determine factors causing diurnal and seasonal variations in discharge. Discharge measure-
ments were taken during periods which displayed different climatological conditions; diurnal variations
were measured within selected twenty-four hour periods. A continuous stage recorder was used to measure
seasonal variations in stream flow. Tributary stream discharge was also measured.
Climatological data recorded at the nearby Kluane Lake Station were utilized for hydro-climatological
analysis. Available measurements included temperature, wind direction and velocity, cloud cover and type,
precipitation, atmospheric pressure, humidity, and incoming short-wave radiation.
Shifts of Kaskawulsh Glacier meltwater drainage from the Slims to the Kaskawulsh River are the major
factor in intraseasonal variations of discharge. Otherwise, Slims River drainage was found to vary diurnally
and seasonally in accordance with certain climatological and physiographic factors. These include glacier
ablation, exposure direction and surface area of the watershed surface, ice-dammed lake drainage, short-wave
radiation absorption, cloud cover, precipitation, and temperature. Discharge varied directly with the general
increases and decreases in short-wave radiation and seasonal temperature. Intensity of rainfall does not always
have a direct relationship to discharge.
lntroduction
Hydrological studies were conducted on the Slims
River during the summer of 1970. This river is important
to an understanding of the regional environment because:
( 1) it is the major source of water for Kluane Lake, the
largest lake in the Yukon Territoty; (2) it behaves anom-
alously from summer to summer, thus affecting lake
levels and shoreline morphology; and ( 3) it is one of the
two meltwater outlets of the Kaskawulsh Glacier.
Geomorphic studies have previously been conducted in
the Slims River area. Fahnestock (1969) described char-
acteristics and chronology of the Slims valley train, pro-
viding supporting evidence to Bostock's (1952; 1969) hy-
pothesis that the Slims River has experienced drainage
reversal in postglacial time.
The purpose of the study reported here was to deter-
mine factors causing diurnal and intraseasonal variations
in discharge. To accomplish this, discharge measurements
of the river were taken during periods which displayed
different climatological conditions. In order to gain in-
sights into diurnal variations, a series of measurements
wete-takert ·within-selected tWentycfour nour periods;·--
seasonal changes were compiled continuously by stage
recorder. Discharge measurements of tributary streams
were also taken to determine what percentage (or re-
mainder) of the Slims' discharge was composed of Kaska-
wu,lsh Glacier meltwater.
*Department of Geography, University of Michigan, at time of
writing. Present address: North Carolina-Central Univer~ity,
Durham
143
Climatological data from the Kluane Lake meteorolog-
ical station utilized in this study included daily mea-
surements of temperature, wind direction and velocity,
cloud cover and type, precipitation, atmospheric pres-
sure, humidity, and incoming short-wave radiation. Inter-
pretation of the climatic data was useful in the identifi-
cation of factors which influence discharge variations.
Study area. The Kaskawulsh Glacier in the Icefi.eld
Ranges of the St. Elias Mountains drains eastward a dis-
tance of 72 km to its end moraine (Plate 1) 1 • At this
point two meltwater streams-the Kaskawulsh and Slims
Rivers-emerge from the glacier snout and drain 'divergent
valleys. The Slims River flows from the north edge of the
Kaskawulsh Glacier's end moraine into Kluane Lake. It
enters the lake at mile 1059.8 of the Alaska Highway,
eventually draining to the Bering Sea via the Yukon River
system. The Slims River stretches 22.5 km over a valley
floor composed of glacial outwash. Its floodplain is
about 1800 m wide, except in areas where tributaries
have built alluvial fans which constrict the valley floor.
The Slims and Kaskawulsh Rivers share the runoff from
a2100_km~_drainage_hasin in_theJcefi.eld Ranges.Ap-_
proximately 1450 km2 of this watershed is covered by
Kaskawulsh Glacier ice (Richard Rangle, personal com-
munication, in Fahnestock, 1969, p. 161).
Tributary streams (Fig. 1), which enter the river below
the glacier terminus, supply the Slims with snowmelt as
late as July, depending on both the amount of winter
snow accumulation and climatic-conditions. On the up--
per portions of fans, which are developed from the
1 Plate 1 is a map inside the back cover of this volume.
144 ALBERTP.BARNETT
Q Ablation moraine
!illillTil Moraine • Bedrock
~ Alluvial flats /
~ Alluvial fans
D Valley train
Feet
120
100
80 _.......,_N
60
40
20 ···-.................... -....................... .
0
-2 -1 0 2 3 4 5 6 7 8 9 10 11 12 13
Scale in miles
Fig. 1. The Slims River valley (from Fahnestock, 1969, p. 163; locations of cross sections discussed by
Fahnestock should be disregarded).
tributaries, runoff infiltrates the fans but reappears at the
edge of the river as small springs. Throughout the sum-
mer months the larger fans supply the Slims with snow
and glacial melt. Of the larger tributaries, Canada and
Bullion Creeks are glacially fed, whereas Vulcan and
Sheep Creeks are supplied with snowmelt from high
neve fields. The ·canyon walls of the lower segments of
these streams exceed 30 m and large boulders cluster in
their narrow flood plains.
Canada Creek, the largest of the tributaries, enters the
Slims some 90 m downstream from the Kaskawulsh Gla-
cier end moraine on the west slope of the valley. The up-
per portion of the fan is composed of coarse material;
the lower two-thirds of the fan consists of gravel to silt-
size material and has no vegetation cover.
Bullion and Sheep Creeks enter approximately 14 km
and 13 km downstream on the west side of the valley.
The upper two-thirds of their fans are wooded. The low-
er thirds are partially covered with thick grasses and
muskeg.
On the Bullion Creek floodplain lSo/v-20% of the sur-
face has been recently reworked by-migrating, braided
flow; major changes have occurred during peak runoff
periods. Mining and road alterations across Bullion Creek
have also modified its migration pattern.
Vulcan Creek, a snowmelt stream, drains the eastern
slope of the Slims River and enters the main stream ap-
proximately 16 km below the Kaskawulsh Glacier termi-
nus. On the upper portions of the Vulcan fan, stream
flow infiltrates gravel-sized alluvium to reappear on grass
and muskeg lower on the fan.
Field methods. Discharge and stage measurements were
taken at the Slims River bridge. This is the most conve-
nient location for discharge observations because a 122-m
long bridge funnels all water into two narrow channels.
Because there is a high permafrost table (less than 1 m
below the surface) subsurface flow is negligible. Vertical
markings painted on the downstream side of the bridge
provided reference planes to measure the vertical angle
created by the force of the water on a handline-suspended
current meter and sounding weight. Starting at the west
bank, depth readings were taken at 1.5-m intervals and
velocity readings were taken at 3-m intervals. Water
height was measured by stage recorder. Water tempera-
ture was also recorded prior to each discharge measure-
ment.
Observations of tributary stream flow were made at
Bullion, Sheep, and Vulcan Creeks. Steam discharge,
water temperature, maximum and minimum air tem-
perature, and precipitation were measured at these
c
c )
c
0
0
c
c
c
0
c
c
)
/
)
-,
' "
" j
' ./
HYDROLOGICAL STUDIES OF THE SLIMS RIVER
0. 0
5.0
I 0. 0
15.0
0.0
5.0
10.0
15.0
DATE
30JUN70
08JU L70
15JUL70
06AUG70
TIME
3PM
7PM
3AM
3PM
Q(ch)
1348
1991
3624
351
A(ft2)
555
555
79 2
o38
G.H.(ft) SYMBOL
1.7
2. 1
3.0
1. 5
~;~A
·· .. ·····--................................ ..
20.0
L-~~--~~--~_.--L--L~~~~--~~
Fl 0 I 0 20 30 40 50 60
DATE TIME Q(cls) A( ft2) G. H.(ft) SYMBOL
30JUN70 3PM 249 2 1065 1.7
08JU L70 7PM 313.4 1597 2. 1
15JUL70 3AM 3325 1496 3.0
06AU G 70 3PM 517 1532 1.5
CHANNEL I
~-~:··~·:·::·:,~:,~.-~-,:~··::·o;··_,.,~,:··:~·o··o:o·:·~,~··:··.:o·,:~:·::···oco··:oJ·;j;i;:•·~
·,.. ..--/ ·,·... ' /
\ ·.~ -~
\''· . ·-/ \.::·---~-____ /~-------:''.;:::> .
.. ...._ ' ,-I ',__ ',, .. -------.,.---.J
'"·. t '-----/ / '"'""" "
I I I -. • //
I I I I -;-·-·:··-···-:-···--·-;---···: I . . I I I I I . I I I I
20.0
25.0
FT 0 10 20 30 40 50 60 70 80 90 100 110
Fig. 2. Cross sections of the two Slims River channels showing depth variations throughout the two months of obser-
vation.
TABLE 1. Cross-Sectional Data, June 30 and August 6
CHANNELl CHANNEL II
DIP* Depth (m) .DIP* Depth (m)
(m) (ft) June 30 Aug. 6 (m) (ft) June 30 Aug.6
24.7 81 0.00 0.00 12.2 40 0.00 0.00
25.9 85 0.94 0.82 13.7 45 0.73 0.76
27.4 90 1.88 1.28 15.2 50 1.74 1.71
29.0 95 3.08 2.87 16.8 55 2.44 2.62
30.5 100 3.38 3.41 18.3 60 4.08 4.57
32.0 105 3.78 4.30 19.8 65 4.42 5.49
33.5 110 3.96 4.36 21.3 70 4.97 5.94
35.1 115 3.93 4.27 22.9 75 4.82 7.19
36.6 120 3.63 4.30 24.4 80 4.88 7.68
38.1 125 3.63 3.69 25.9 85 5.18 7.68
39.6 130 2.96 2.83 27.4 90 4.60 7.62
41.1 135 1.80 1.98 29.0 95 4.60 7.77
42.7 140 1.16 1.01 30.5 100 3.87 7.07
44.2 145 0.00 0.00 32.0 105 3.44 6.31
33.5 110 3.41 5.49
35.1 115 3.41 3.51
36.6 120 2.87 3.96
38.1 125 2.71 3.11
39.6 130 1.58 2.50
41.1 -135 0.~8 .. 1.22
42.7 140 0.06 0.49
44.2 145 0.00 0.00
*DIP: distance from initial point.
145
146
stations. All tributary stations were located above their
alluvial fans to eliminate the complexities involved in
braided stream measurements. Observations on Vulcan
Creek were made 30 m above the head of the fan along a
straight 15-m reach. Rod discharge measurements, using
a number 622 Price pygmy current meter, were made at
these stations.
Stream Geometry
The Slims River is divided into two separate channels
by the center pile and foundation of the Alaska Highway
bridge, mile 1059.8. Channel I has a width of 19.8 m
from the west bank to the center pile and Channel II
measures 32.0 m from the center pile to the east bank.
The depths of both channels vary greatly (Fig. 2 and
Table 1). The deepest point in Channel I varies from 3.3
to 5.8 m and in Channel II from 4.6 to 8.2 m.
Although the cross-sectional area of Channel II is
greater than that of Channel I, the discharge of Channel
II is often less than that of Channel I (Table 2). Channel
I is located near the concave bank just downstream
from the axis of bend in a meandering segment of the
Slims River. This is the section in the meandering stream
that experiences the greatest velocity (Leopold, Wolman,
and Miller, 1964, p. 299).
It should be noted that although Channel I has higher
velocities and discharge, Channel II experiences greater
scouring and filling. Studies of hydraulic geometry have
shown that the mean bed elevation at a river cross section
depends not only on water discharge, but is related to
changes in width, depth, velocity, and sediment load
(Leopold, Wolman, and Miller, 1964, p. 230). During
periods oflow discharge and velocity (in August), the
highest discharge shifts to the previously deepened Chan-
nel II.
Flow Characteristics
Diurnal discharge variations. Diurnal discharge mea-
surements were taken on different days as the summer
progressed. Table 2 summarizes the observations. The
data reveal that peak discharges occur between 2100 and
0300 hours; lows occur in early afternoon. Given normal
conditions the greatest ablation occurs when solar energy
is most abundant; this generally occurs between the
hours of 1300 and 1500 mean solar time. The time lag
between peak ablation and peak discharge readings can
be attributed to the combined length of the glacier ab-
lation surface and the distance between the gauging sta-
tion and the terminus of the glacier.
The magnitude of discharge during high flow periods
is dependent on geomorphic factors such as glacier type,
slope and exposure, surface area ofthe zone of ablation,
glacier sediment cover, and drainage of ice-dammed
lakes. Climatological factors include radiation absorp-
tion, cloud cover, precipitation, and temperature. Of
these variables, only the climatological factors are con-
sidered in this paper.
ALBERTP. BARNETT
It is found that although discharge varies during 24-
hour periods, the factors causing these variations are due
to the general tendency of the climatological variables
during the period of observation rather than to their ab-
solute value during measurement. A trend, to be effect-
ive, must extend a period of days prior to the discharge
measurement. Exceptions to this are cases of intense pre-
cipitation and drainage of ice-dammed lakes which
initiate major discharge fluctuations within twelve hours
after occurrence.
Intraseasonal variations. Intraseasonal flow variations
are given in Table 2. Measurements were taken at the
same hours on different days in order to establish a bet-
ter picture of seasonal progression. Measurements taken
at 1400 and 1500 hours show gradual variations in dis-
charge and cross-sectional area for three distinct periods.
The first two periods are characterized by gradual in-
creases in area and discharge, each followed by a decline.
The spring warming trend and associated snowmelt is
the apparent cause for the increase in discharge for the
first period (June 30-July 9). The invasion on July 5 of a
storm system with associated precipitation contributed
to the high runoff. By July 9, high barometric pressures
and decreasing temperatures contributed to a decrease
in runoff (Figs. 3 and 4). Subsequently, temperatures
remained relati·.rely low for the rest of the summer.
This, and the reduction of snow available for melt, ac-
counts for the discharge not reaching its previous level.
The second decrease (from Period II to Period Ill) was
caused by a major shift to the Kaskawulsh Glacier melt-
water from the Slims River to the Kaskawulsh River.
This phenomenon is extraordinarily important to the
regimen of the Slims River and has been observed on at
least two other occasions during the 1960's (Melvin
Marcus and Philip Lipton, personal communications).
The subject is treated in a later section.
Effects of climate on discharge. Because the Slims
River is located in a rain shadow on the leeward side of
the St. Elias Mountains, the precipitation is low, On
days when precipitation occurred, however, slight vari-
ations in discharge were recorded. On July 8, for ex-
ample, there was 22.6 mm of precipitation. Two dis-
charge measurements were taken on this day and one
on the following day. Unfortunately, more measurements
are not available for this period since the continuous
stage recorder malfunctioned. In comparing measurements
taken at 2200 hours on July 8 with measurements taken.
on July 5 at a corresponding time with no precipitation,
a July 8 increase in discharge is apparent (Table 2).
Although on July 9, 2.8 mm of precipitation was re-
corded, reduction in discharge, cross-sectional area, and
velocity were measured. Reduced short-wave radiation
was received on July 8 and July 9. This, along with lower
temperatures, reduced ablation and net water runoff into
the Slims River. The amount of precipitation on July 8,
however, was more than enough to compensate for the
lost glacial meltwater discharge and thereby resulted in a
c
c
c
c
0
0
0
c
c
G
c
' )
"' _)
"\
..)
J
~
.)
' v
' ..,
r:..
6/
....,
HYDROLOGICAL STUDIES OF THE SLIMS RIVER 147
'"~ ~ 0.5 -'
0.0 • •
I__
--l_ -• 1 IU
PRECIPITATION
I ' '" "~ ';:: 50 0
~
0.0
935.0 .
I
9 25.0
"' I
-" E
915 0 0
I
905.0 25 31 I 0 15 20 25 30 10 15 20 25 31 5 I 0
MAY JUNE JULY AUGUST
Fig. 3. Mean daily precipitation, cloud cover, and barometric pressure at Khiane Lake meteorological station,
May-August 1970.
discharge increase. The amount falling on July 9 was not
enough to compensate for reduced glacial melt, and
therefore a reduction in discharge was experienced.
With the rise in stage accompanying flood passage
through a gauging station, there is an increase in veloc-
ity and sheer stress on the stream bed. As a result
there is a tendency for scouring to occur during high
flow periods. Figure 2 shows the changes in cross
u..
0
~
~ ~ .. c.
60~
I
5J
E {! 40
3020 30 9
section during passage of snowmelt increase for the
Slims River. Observations began on June 30, 1970. It is
seen that the bed level at this time was about 4.5 m be-
low the gauging datum and the discharge was 38.2 and
70.2 m 3 /sec, respectively, for Channels I and II. By
July 8, the discharge increased to 68.2 and 92.8 m 3 /sec
and the bed level dropped 1.5 to 3.0 m. On July 10-11,
a noticeable increase in stage (from 0.58 to 0. 70 m) was
recorded (Table 3). A diurnal variation from 0.64 to
9 19 29 8 18
May June July August
Fig. 4. Mean daily temperature at Kluane Lake meteorological station, May-August 1970 ..
Time Gauge
Period Date (Eastern Yukon height
Daylight) (m)
I June
30 1500 0.52
July
5 1400 0.67
5 I 1800 0.67
5 2100 0.67
6 0001 0.70
6 0700 0.70
6 1300 0.70
8 1900 0.64
8 2200 0.64
9 1400 0.55
II July
15 0300 0.91
19 1500 0.61
19 1800 0.61
19 2100 0.61
20 0001 0.64
20 0300 0.64
20 0900 0.64
30 1400 0.76
'
Ill August i
4 1500 0.49
4 1800 0.49
4 I 2100 0.49
5 0001 0.49
5 0300 0.49
5 0900 0.49
6 1500 0.46
7 1200 0.43
7 1500 0.43
7 2100 0.43
8 0001 0.43
12 ' 1500 0.37
Cl 0 0 ()
-----------
TABLE 2. Slims River Discharge, Summer 1970
Channell Channell I
Cross-section Velocity Discharge Cross-section Velocity
area (m2 ) (m/sec) (m 3 /sec) area (m2 ) (m/sec)
51.6 0.74 38.2 98.9 0.71
39.9 1.21 48.3 107.9 0.63
39.9 1.12 44.7 107.9 0.67
39.9 1.25 49.9 107.9 0.82
62.3 1.14 71.0 137.6 0.46
62.3 0.96 59.8 137.6 0.45
58.2 1.01 58.8 150.2 0.58
58.1 0.97 56.4 149.6 0.43
58.1 1.17 68.2 149.6 0.62
56.1 0.81 45.9 146.4 0.39
73.6 1.39 102.3 139.0 0.68
56.9 1.05 59.8 140.7 0.68
56.9 1.14 64.7 101.4 0.47
56.9 1.28 73.0 101.4 0.51
64.2 1.19 76.4 99.5 0.55
58.1 1.22 70.9 97.5 0.54
58.1 1.00 58.1 97.5 0.47
56.0 0.65 36.4 151.5 0.50
54.8 0.14 7.7 142.9 0.09
54.8 0.14 7.4 142.9 0.08
54.8 0.17 9.4 142.9 0.09
54.8 0.18 10.1 142.9 0.11
54.2 0.16 8.7 140.7 0.11
54.2 0.18 9.6 140.7 0.09
59.3 0.17 10.1 142.9 0.10
52.8 0.18 9.5 138.7 0.10
52.8 0.15 7.7 138.7 0.07
52.8 0.15 7.7 138.7 0.09
52.8 0.19 10.0 138.7 0.10
51.3 0.15 7.7 137.7 0.07
0 0 0 0
Discharge
(m3 /sec)
70.2
68.0
71.8
88.1
63.3
62.4
87.1
64.3
92.8
57.1
94.1
95.7
47.7
52.1
54.7
52.7
45.9
75.8
12.9
11.1
13.0
15.9
15.5
13.4
14.3
13.9
9.6
12.6
14.3
9.6
Both channels
Cross-section Discharge
area (m2 ) (m3 /sec)
150.5 108.4
147.8 116.3
147.8 116.5
147.8 138.0
199.9 134.3
199.9 122.2
208.4 145.8
207.7 110.7
207.7 161.0
202.5 103.0
212.6 196.4
197.6 155.5
158.2 112.4
158.2 125.1
163.7 131.1
155.6 123.6
155.6 104.0
207.5 112.2
197.7 20.6
197.7 18.5
197.7 22.4
197.7 26.0
194.9 24.2
194.9 23.0
202.2 24.4
191.5 23.4
191.5 17.3
191.5 20.3
191.5 24.3
189.0 17.3
(l C)
......
~
00
F;
iii
::>0
>-i
""' ~
~
r'"" ,j
HYDROLOGICAL STUDIES OF THE SLIMS RIVER 149
TABLE 3. Slims River Gauge Height tation. It is speculated that a draining ice-dammed lake
Gauge height in meters supplied the Slims River with additional water in suffi-
Date 1800 hr Midnight
cient quantities to cause an increase in stage height. A
0600 hr 1200 hr number of small ice-dammed lakes are located along the
June 30 0.52 0.52 0.52 0.55 lateral margin of the Kaskawulsh Glacier. These have
July 1 0.52 0.52 0.52 0.58 been observed to drain in a matter of a few hours (Mel-
2 0.58 --0.61 vin Marcus, personal communication). One of these
3 0.61 0.61 0.58 0.70 lakes apparently drained on July 14 as shown by an in-
4 0.70 0.64 0.64 0.76 crease in stage from 64 to 76 mm within a period of 10 5 0.73 0.70 0.67 0.70
6 0.70 0.70 0.61 0.70 minutes. On July 17, the last day of the high flow period,
~. 7 0.70 0.67 0.64 0.67 precipitation created very small stage fluctuations.
8 ----
9 --0.55 0.58 The period July 18-20 experienced a reduction in
10 0.58 0.58 0.58 0.67 stage. This was in part a response to the limited amount
11 0.70 0.67 0.64 0.70 of incoming short-wave radiation (Fig. 5). Cross-sectional
12 0.73 0.70 0.67 0.73 area reduction (filling) occurred with the decrease of ve-13 0.73 0.70 0.70 0.79
14 0.82 0.76 0.73 0.76 locity and discharge.
15 0.76 0.73 0.73 0.76 For the three-day period, July 24 to July 26, a total of 16 0.76 0.70 0.70 0.73
17 0.76 0.76 0.67 0.70 13.7 mm of precipitation fell, with 85% of this total oc-
18 0.67 0.67 0.61 0.64 curring on July 25. Discharge measurements were not
19 0.67 0.64 0.58 0.64 taken during this period, although stage records reveal an
20 0.61 0.61 0.64 0.64 increase from 0.61 m on July 24 to 1.01 m.onJuly 26. 21 0.64 0.61 0.61 0.67
22 0.67 0.67 0.64 0.67 The accumulated precipitation for this period was not
~ 23 0.67 0.67 0.67 0.70 enough to cause such an increase in stage. This increase, )
24 0.73 0.70 0.70 0.76 therefore, must be attributed to some other cause. Tern-
25 0.79 0.82 0.82 0.91 perature and radiation data show that the period in 26 1.01 0.94 --which the peak daily mean temperature occurred coin-27 ----
28 ----cided with the period that received the greatest short-
29 ----wave radiation (July 17 through August 1 ). The resulting
30 -0.76 0.76 0.76 increase of snowfield and glacier melting is the apparent
' 31 0.73 0.70 0.64 0.64 cause of the stage increase for this period . .J Aug. 1 0.64 0.61 0.61 0.61
2 0.61 0.58 0.55 0.55
The Shift in Glacier Runoff 3 0.55 0.55 0.52 0.52
4 0.49 0.49 0.49 0.49
Between July 30 and August 4, 1970 the stage of the 5 0.49 0.49 0.49 0.46
6 0.46 0.46 0.43 0.43 Slims River dropped from 0.76 to 0.49 m, cross-sectional
7 0.43 0.43 0.40 0.40 area decreased from 207.5 to 197.7 m 2 , and velocity in
8 0.37 0.40 0.43 0.40 tl .. :: two channels decreased from 0.65 to 0.14 m/sec ~· 9 0.37 0.40 0.37 0.37
10 0.37 0.37 0.37 0.37 (Channel I) and 0.50 to 0.09 m/sec (Channel II). This
11 0.37 0.37 0.37 0.37 was the result of a major shift of Kaskawulsh Glacier
12 0.37 0.37 0.37 0.37 meltwater into channels of the Kaskawulsh River, de-
13 0.37 0.37 0.37 0.37 priving the Slims River of more than three-quarters of its
14 0.37 0.37 0.37 0.37 previous discharge. A gradual drop in stage continued
"' Note: Time is Eastern Yukon Daylight. for two weeks after the initial decline (Table 3). This
.J event occurred at the end of the period that experienced
0. 73 m was maintained until July 13. A peak stage of the peak mean daily temperature (Fig. 4 ).
0.82 m above the gauge datum was achieved at 0600 hr The diurnal discharge variations during August (Period
on July 14, with a low stage of 0. 73 m at 1800 hr. This III) were of smaller magnitude than those of the previous
leYeLwas_maintaineduntil_J uly 17. _The_ peak stage.dur" .. period.-The.August.variation-pattem-more.truly-repre---·
"
ing this period occurred between midnight and 0300 sents the diurnal pattern for tributary streams than do
.;; hours and the low stage occurred between 1400 and the June and July patterns. This is because approximately
1700 hours. 50% of the Slims River flow after the shift at the end of
Previous to July 10, a major storm system moved July was composed of tributary meltwater, whereas only
through the area, accompanied by heavy cloud cover 10% of its earlier discharge consisted of tributary flow.
and high precipitation. The lowest recorded incoming Peak flow in August occurred around midnight. This is
~ short-wave radiation occurred during this period. The similar to the discharge pattern in June and July before
-' stage increase on July 10 occurred in conjunction with the drainage shift. However, it was observed that the
clearing weather and a jump in insolation. The increase high flow periods in August were somewhat more ex-
on July 14 was not due to intense insolation or precipi-tended than high flows in the earlier period. Although
""
150 ALBERT P. BARNETT
z
0
<
§ I 1\ . -,..,
~
>
,..:
:3
~ I I \ I \ ;· \ F \ I \ I \
28JUL70 I 29JUL70 I 30JUL70 I 31JUL70 I OIAUG70 I 02AUG70
Fig. 5. Insolation at Kluane Lake meteorological station, July 28 through August 2, 1970. Each division on the vertical scale rep-
resents 0.5 langleys.
the time of day for peak ablation occurs simultaneously
for tributary sources in the watershed, the differences in
distances between tributary sources and the Slims River
gauging station cause peak meltwater from each of the
tributaries to reach the gauging station at different
times. This lag effect results in extended high-flow peri-
ods that had been previously obscured by the Kaska-
wulsh Glacier runoff.
Conclusions
The most significant element in the summer 1970
regimen of the Slims River was the shift of Kaskawulsh
Glacier meltwater runoff in early August. Deprived of its
principal water source, the Slims River made only mini-
mal contributions to Kluane Lake during a normally
high flow period. The impact of the drainage shift was
accentuated by climatic conditions during the summer
and earlier 1969-1970 accumulation season.
The snowfield and glacier budget year 1969-1970 was
exceptionally dry along the continental front of the Ice-
field Ranges (see Marcus, pp. 219-223, this volume). Thus
less snow was accumulated to feed tributary streams
during the summer ablation period. Most of the neve
fields were exhausted by the time the Kaskawulsh Gla-
cier drainage shift occurred. Counteracting this effect
was the relative coolness and low insolation in June and
July. This depression of incoming energy was insufficient
to prevent the melting of the shallow snowfields in the
tributary watersheds; however, it did reduce the usual
rates of glacier ablation.
The combination of less glacier runoff and low tribu-
tary snow storage accounts for appreciably lower Slims
River-dischargein--19'70-than-in-preceding-years;-Peak---
discharge values are, for example, less than half those re-
corded by Fahnestock in 1965 and Alford in earlier years
(Fahnestock, 1969, Table 1). When the Kaskawulsh drain-
age shift occurred, extremely low discharges followed.
Less than 25m3 /sec flowed past the Slims River bridge
in August 1970. In comparison, Fahnestock (1969) ac-
counted for approximately 85m3 /sec from tributary
sources in late July 1965. Thus it seems that regional cli-
matic events can also exert a major influence on year-to-
year discharge of the Slims River. Because the Slims is
the principal feeder source for Kluane Lake, these effects
are inevitably significant to lake level and to shoreline
development.
Acknowledgments
My gratitude is extended to the Arctic Institute of
North America and the Canadian Department of Indian
Affairs and Northern Development for financial and lo-
gistic support. The advice given by M. Leonard Bryan
and Melvin G. Marcus on observational procedures is truly
appreciated. I am sincerely grateful to the Commission on
Geography and Afro-America of the Association of Ameri-
can Geographers for its encouragement.
References
Bostock, H. S. (1952) Geology of Northwest Shakwak Valley,
Yukon Territory,Mem. 247, Geol. Surv. Can.
Bostock, H. S. (1969) Kluane Lake: Its drainage and allied prob-
lems (115 G, and 115 F E),Paper 69-28, Geol. Surv. Can.
Fahnestock, R. K. ( 19 69) Morphology of the Slims River, in
I cefield Ranges Research Project, Scientific Results, edited by
V. C. Bushnell and R. H. Ragle, Vol. 1, pp. 161~172, Am. Geogr.
Soc. and Arctic Inst. North Am., New York.
Leopold, L. B., Wolman, M.G., and Miller,]. P. (1964) Fluvial
-Processes in Geomorphology,-Freeman Press,--S-an-Francisco~--
0
c
0
0
0
0
0
c
I
- i
!
Oi
c
c
I ) ~
,, ES U?CES l\'2-AAR'l l. ..~ 1 f the Interior
U.S. Departxnent o
•
PUBLISHED JOINTLY BY THE
ICEFIELD
RANGES
RESEARCH
PROJECT
SCIENTIFIC RESULTS
VOLUME 4
AMERICAN GEOGRAPHICAL SOCIETY
AND THE
ARCTIC INSTITUTE OF NORTH AMERICA
Prc:p~rly of 2Uf
AK. ftfSOORCES lii&RY
ICEFIELD RANGES RESEARCH PROJECT
SCIENTIFIC RESULTS .
Volume 4
Edited by
VIVIAN C.LBUSHNELL
American Geographical Society
and
MEL VIN G. MARCUS
Arizona State University
AlA \':~A r::r.:rr;::v-r~ r ~~'~·P'( !l'o..,~ +o._, li .... t ......... , .• ..,. '"''".·w.._,..,) ........ _.. .. \.1 t:;~
u_s_ f)cr~.r'c~~f'·;,t of -U.-.c Irh:,~ior
Published joint/y by
AMERICAN GEOGRAPHICAL SOCIETY, NEW YORK
and
ARCTIC INSTITUTE OF NORTH AMERICA, MONTREAL
1974
APR 21 191!