HomeMy WebLinkAboutEffects of hunting on rock ptarmigan along the steese highway 1972EFFECTS OF HUNTING ON ROCK PTARMIGAN
ALONG THE STEESE HIGHWAY
Robert B. Weeden
State of Alaska
William A. Egan
Governor
Department of Fish and Game
Wallace H. Noerenberg
Commissioner
Division of Game
Frank Jones, Acting Director
Donald McKnight, Research Chief
Alaska Department of Fish and Game
Game Technical Bulletin No. 2
July 1972
Financed through Federal Aid in Wildlife Restoration Project W-17-R
ACKNOWLEDGEMENTS
M. Thomas Dean, 1960
Rodney Herrick, 1961-1962
David Hatler, 1963
James Erickson, 1964
John Trent, 1965-1966
Philip Headley , 1967
Jerry McGowan , 1968-1969
Dale Haggstrom, 1968
Sandra Kogl, 1968
These people, most of them former students in wildlife at the University of Alaska, have
contributed a great deal to all phases of the Department's research on ptarmigan . Phil
Headley, Dale Haggstrom, and Sandra Kogl, through their long hours at the hunter checking
station in 1967 and 1968, obtained the information on harvest that is so important to
this report. I deeply appreciate their help.
i.
CONTENTS
INTRODUCTION . . . . . . . . . . . ...
The Steese Highway Ptarmigan Hunter . 2
Birds in the Bag 5
Hunting Pressure 9
Visible Effects of Hunting on Ptarmigan Populations . 11
Manipulating the Harvest 15
Summary .. . 17
APPENDIXES 21
ii.
TABLES
Table 3
Table 2 4
Table 3 6
Table 4 ... .. . .... 7
Table 5 8
Table 6 10
Table 7 12
Table 8 14
Table 9 16
Appendix I . 19
Appendix II . 20
Appendix Ill .. ..... . 21
Appendix IV .. ..... . 21
iii.
INTRODUCTION*
Every summer from 1959 to 1969 I watched ptarmigan in the high country northeast
of Fairbanks along the Steese Highway. This research was funded by the Alaska
Department of Fish and Game with money from the Federal Aid in Wildlife Restoration
Act. My assistants and I watched cocks defend their territories, observed hens raise their
young, and saw ptarmigan gather into great flocks in early fall. Our main purpose was
to record and interpret changes in behavior, productivity, and survival that seemed most
closely related to the rise, fall, and recovery of breeding populations. Out of general
interest we watched hunters pursuing ptarmigan in the fall, but for many years I believed
that hunters were a negligible factor in the lives of ptarmigan in the area. Very recently
I realized that fall hunting often affected the ratio of young to old cocks in spring, and
in 1968 awoke to the possibility that spring hunting could reduce breeding stocks.
These belated thoughts led to a reevaluation of hunting as it might affect interpretation ,
of our data on population changes. Very soon I realized that the information I was
studying could be of real value to the Department's management program, not so much
because of any current problems but in view of the anticipated growth of Fairbanks.
If a few hunters can have visible effects on the age structure and numbers of ptarmigan,
it seems likely that two or three or ten times as many hunters would create situations
requiring regulatory changes or other managerial action.
In this report I first sketch the present hunting situation in the Eagle Summit area of
the Steese Highway (that is, how ptarmigan are hunted, when they are sought, and what
kinds and numbers are shot). Next I focus on the ptarmigan themselves to show how
hunting influences their aggregate composition and numbers. Finally, I discuss some
potential management questions and try to provide a choice of answers-or at least point
out how some of the answers can be obtained.
*Dr. Weeden was a Research Biologist for the Alaska Department of Fish and Game when
he dfd his work. He is now Professor of Wildlife Management at the University of Alaska,
College.
1
THE STEESE IDGHWAY PTARMIGAN HUNTER
Ever since the turn of the century men have traveled between the Yukon and the Chena:
across the Birch Creek lowlands out of Circle City, up Crooked and Mammoth creeks
to Eagle Summit, westward down Eagle Creek and up Twelvemile Creek to Twelvemile
Summit, down the long grade of the Chatanika River, and over Cleary Summit to Fox
and Fairbanks. For 25 years they walked in summer and rode behind horses or dogs
in winter. Then in 1927 the last stretch of Steese Highway was completed at Miller
House and the days of walking were over.
The Steese was a working man's road for 20 years. When placer mining lost the battle
to inflation, however, tourists and hunters began to make up the bulk of the Highway's
traffic. The same sort of change occurred in the l 940's for hunting. Before World War II
caribou, moose, and ptarmigan were sources of meat for hungry miners. In the late 40's
and early SO's the dwindling numbers of market and larder hunters were swamped in
a tide of recreationists from Ladd Field, Eielson Air Force Base, and the booming town
of Fairbanks, all driving the Steese to intercept the anticipated fall movement of caribou.
Records are sparse, but very likely there were more individual hunters along the Steese
in the ten years from 1945 to 1954 than ever before or since.
A noticeable decline in numbers of hunters occurred late in the 1950's and in the first
years of the present decade. This probably resulted from: a) a decline in the
defense-associated boom in Fairbanks; b) the opening of the Denali Road in 1958 and
the road to Healy in 1965; c) increasing use of airplanes and swamp buggies for hunting
in the Alaska Range; and d) the declining frequency of caribou movements across the
Steese in fall.
For at least six or eight years the general pattern of hunting has stayed the same on
the upper Steese Highway, although the number of hunters and their success has varied
with such things as the availability of caribou in the area and the supply of ptarmigan.
In the following section, I will try to describe this pattern and give some details about
the ptarmigan killed.
Seasonal Patterns
Ptarmigan hunting begins-officially-on either the 10th or 20th of August in Game
Management Unit 20, in which Eagle Summit lies. Opening day on the Steese is a far
cry from "The Twelfth" in Scotland, when gunners man the butts on the red grouse
moors, and it bears no resemblance to the holiday atmosphere on the first day of pheasant
shooting in the Dakotas. No fanfare, no bustle; you might sit on a warm rock above
the highway most of opening day and hear nothing but the berries ripening. Only 11
parties of hunters were recorded at our checking station during opening week in 1968.
(In 1967 only four parties stopped during the first two weeks of the season-mainly because
the road was washed out from August 12 to 18.)
Throughout August ptarmigan steadily combine into larger and larger flocks. Broods meet
and join other broods, and brood aggregations attract small parties of old males and
unsuccessfully-nesting females. In the warm days of early and mid-August the birds are
quiet and hard to find. Sometime in the last few days of August, or very early in
September, the weather turns cool; perhaps a blustery north wind bumps a few snow-laden
clouds into Eagle Summit, and overnight the reddish glow of kinnikinnik leaves is snuffed
2
out by a thin white blanket of snow. Then the ptarmigan seem to come alive. They
begin to call and display to each other during the early morning feeding period. The
flocks get bigger as if by magic, and fly from ridge to valley or valley to slope at any
excuse.
Simultaneously the hunters begin to appear in greater numbers. This increase is partly
due to the improved ptarmigan hunting (in 1968, 44 out of 81 parties stopping at the
checking station said they came up the Steese primarily to look for ptarmigan), but is
also a reflection of the rising urge of sportsmen to-go out prospecting for moose or caribou.
In September the tundra vegetation becomes "winterized," the ptarmigan flocks reach
peak size (commonly in excess of 100 birds per flock in the larger aggregations), and,
in the last part of the month, snow becomes a perm;anent part of the scene. Ptarmigan
hunting is potentially at its best. Whether it is good or not depends on daily weather
conditions and the general abundance or scarcity of birds.
About the last of September the State Department of Highways announces its intention
to stop maintenance on the Steese Highway, effective usually between October 8-15. Many
of those who shoot ptarmigan in August and September are actually sightseers or
lightly-motivated hunters; these usually disappear from the scene early in October. Hunters
with courage or four-wheel-drive vehicles ignore the official closure. These people continue
to hunt until drifting snow closes Twelvemile Summit (mile 85), but in most years only
hunters on snowmobiles get beyond the approaches to Eagle Summit after the end of
October.
The general seasonal pattern, then, includes a slow opening in August, a period of rising
and relatively high interest in September, sustained interest but somewhat fewer hunters
in October, . and a weather-dictated end to the harvest sometime late in October or
November.
Daily Patterns
As one would expect in an area 100 miles or more from the homes of the hunters, there
is a strong tendency for hunters to be out in force on weekends. The day-by-day tally
of birds shot in 1967 and 1968 (Table 1) shows that half or more of the ptarmigan
harvested from the Steese highlands were taken on Saturdays or Sundays.
Table 1. Percentage of total harvest of ptarmigan for 1967 and 1968 taken on each
day of the week.
Percentage of Ptarmigan Shot by Day
Year Total Birds Mon. Tues. Wed. Thurs. Fri. Sat. Sun.
1967 273 13.5 9.9 19.0 3.7 5.5 23.5 24.9
1968 912 1.3 '3.1 5.5 14.0 3.7 29.8 42.5
3
Hunting Methods
We have no statistical details about the way people hunt ptarmigan on the Steese, but
the following generalities describe the situation fairly accurately.
There are some avid upland bird hunters in Fairbanks, and most of them try to spend
at least one weekend a season in the alpine areas of the Steese Highway. A few own
and use bird dogs, but most do not. The main thing which sets this group apart is their
general willingness to hunt for birds even when they don't see any while driving. They
range out from one-quarter mile to two miles from the highway, but almost never go
farther. Almost all of them use shotguns.
The dyed-in-the-wool bird hunter, however, is greatly outnumbered by people who come
prepared to shoot birds only if they see or hear them from the road. Perhaps the best
measure I have of this is an indirect but fairly conclusive one: the rapidly decreasing
chance of having a hunter shoot a banded ptarmigan the farther from the road we caught
the bird. Any local ptarmigan is at least twice as likely to end up in a hunter's pocket
if it lives within a half-mile of an access road, as compared to a bird living farther away
(Table 2). Band returns from birds caught a mile or more from the road occur mostly
because the birds wander towards the road after banding, not because the hunters go
after them.
Table 2. Percentage of bands returned by zone of banding, 1960-1968.
No. No. Percent
Zone Sex, Age Caught Shot Shot
A (up to 1/2 mile from the Male, Adult 228 53 23.2
Steese or access road)* Female, Adult 354 3 7 10.5
Chick 597 61 10.2
B (1/2 to 1 mile from a Male, Adult 159 16 10.1
road) Female, Adult 236 10 4.2
Chick 401 12 3.0
C (over 1 mile from a road) Male , Adult 123 11 9.0
Female, Adult 209 7 3.3
Chick 412 17 3.2
* See Appendix I for a map of these zones.
The casual shooters of ptarmigan also use shotguns more often than rifles , but a fair
number do shoot birds on the ground with small caliber rifles.
Except for highway vehicl es, very little me chanized equipment is now used by ptarmigan
hunters at Eagle Summit. I have never seen tracked vehicles used there. One or two
parties of big game hunters use trucks equipped with huge tires (swamp buggies) to go
4
BIRDS IN THE BAG
up neighboring Golddust Creek each year to a hunting camp; they take a few ptarmigan
en route. Snow machines were used rarely in the fall at Eagle Summit through 1968
but 5 to 15 were in use some days at Twelvemile Summit when caribou were available.
In the spring of 1968, when, for the first time, the Steese Highway was drivable in late
March and April, hunters did use snowmobiles commonly.
BIRDS IN· THE BAG
Total Number Harvested
Our data are sparse and hard to interpret because no attempt was made until 1967 to
find out how many ptarmigan were shot along the Steese in general or at Eagle Summit
in particular. In 1953 a checking station was operated the entire month of September
at Fox (mile 11), and personnel there tallied 238 successful parties with 2,426 ptarmigan.
These birds came from all of the ptarmigan habitat on or near the Steese: Twelvemile
Summit, Eagle Summit, and Harrison Summit, the latter being on a mining road eight
miles from Miller House. The total season kill (including August and October) at Eagle
Summit probably was at least 2,000 ptarmigan. In 1954 the checking station moved
to Faith Creek (mile 69), and in an unspecified period tallied 1,428 ptarmigan. The
following year 226 ptarmigan were shot by 23 parties of hunters checked during eight
weekend days in late August and mid-September. In 1961 a comparable bag (233
ptarmigan) was achieved by 40 parties hunting during 40 days from August 20 to the
end of September.
Our intensive efforts in 1967 and 1968 gave a much more complete record of the season.
The checking station was open daily for at least 16 hours each day from August 10 to
October 9 (1967) and October 13 (1968). Station attendants could determine in most
cases where the birds had been taken. Because of the flood of August 12-15 in Fairbanks,
hunting pressure was unusually light in 1967 throughout the season. The complete absence
of caribou until October made hunting less attractive too. A total of 221 ptarmigan
came through the station, 185 of them rock ptarmigan. Twenty-seven parties took these
rock ptarmigan. All but 22 of the birds were from Eagle Summit.
Ptarmigan were somewhat more abundant in 1968, but the increase in harvest recorded
was mostly due to the presence of more hunters. During that season 80 parties reported
929 rock ptarmigan, and 11 parties took 33 willow ptarmigan. A very large proportion
of the birds (651 rock ptarmigan) was taken by 51 parties hunting off the Eagle Summit
study area. Since the average bag per party was more off the area (12.8 birds) than
on it (8.2 birds), this probably indicates somewhat lower ptarmigan on the study area-an
idea supported by our spring counts of territorial cocks.
In general, therefore, the total harvest of ptarmigan from the upper Steese Highway
probably has fluctuated annually between 100 and 4000 birds, with bags in most years
totaling 400 to 1000 birds. It is hard to convert this into a harvest per unit of area,
but some idea can be gained by assuming that hunters get most of their birds in a strip
two miles wide in areas where roads climb above timberline. This would include a total
of 28 square miles: 22 square miles at Eagle Summit, including the area made accessible
by the road to Berry Camp on Eagle Creek, and six square miles along the old mining
roads south of Miller House (mile 115). This suggests a harvest of 14 to 36 ptarmigan
per square mile in these "average" years. I will try to wring some meaning from this
estimate later in this report.
5
Hunting Success
Because of the casual way many people approach ptarmigan hunting, the only good way
to identify a ptarmigan hunter is by finding out if he shot any birds. Using this as
a criterion, one can see that the number of ptarmigan bagged per successful party varied
from year to year (Table 3). One would logically expect this variation to stem from
changes in the abundance of ptarmigan, but the data we have for comparison show a
poor relationship between fall densities of ptarmigan at Eagle Creek and the number of
birds shot by successful hunting parties (Table 3). However, information for years prior
to 1967 is of doubtful reliability, and judgment should be withheld until better data are
available.
Table 3. Ptarmigan shot per successful party.*
Estimated
Year Birds Per Party Fall Pop.**
1953
1955
1960
1961
1963
1964
1966
1967
1968
10.2
9.8
5.1
5.8
4.5
7.8
7.3
8.2
10.6
(very high)
(high)
475
860
580
450
470
495
510
* These parties averaged 2.0 hunters in 1960, 2.2 hunters in 1967 and 1968.
** Total number estimated in early August in 15 square miles.
The average number of birds in possession in 1968 (10.6) suggests that few people shot
a bag limit (20 per hunter per day). Checking station records show that only three of
the 80 successful parties of hunters shot their limit of ptarmigan (Table 4 ). The legal
limit obviously was more of a hypothetical than actual restriction on the hunters, even
in a year of relatively high bags.
Sex and Age of Birds Shot
Our best data on the kinds of ptarmigan shot in fall come from the 1968 checking station,
when enough birds were handled to allow a week-to-week comparison (Table 5).
There was an overall harvest of one adult per 1.29 juveniles. Except for one week in
August when few birds were handled, there were more juveniles shot, relative to adults,
before September 21 than after that date. In 1968 my reckoning at Eagle Creek indicated
that there should have been one adult for every 1.76 first-year birds early in August.
The sample hunters took from August 10 to August 23 contained one adult per 1.90
young. These data suggest that hunters took juveniles in about the proportion in which
6
T~ble 4. Percentage of total legal bag actually shot by ptarmigan hunters, 1968.
Percent of Legal No. of Percentage
Bag Taken Parties of Total Parties
1-10 30 38
11-20 18 23
21-30 8 10
31-40 5 6
41-50 8 10
51-60 4 5
61-70 2 3
71-80 I I
81-90 I I
91-100 3 4
they existed in the total population at that time. Later in the season the proportion
of young in the bag dropped to around 1.2 per adult. This could reflect either a relatively
high natural mortality among juveniles, or an increasing vulnerability of adults stemming
from behavioral and habitat changes. The sharp drop in proportion of juveniles early
in October is probably due to the movement of adult hens, young females, and some
young males away from breeding areas to lower wintering grounds. Most of the birds
remaining in the high country by mid-October are males, with a high proportion of adults.
Males comprised about half the kill (51 percent) in 1968. However, 55 percent of the
269 adults were males, whereas only 46 percent of the 295 juveniles were males. I think
adult cocks are somewhat more vulnerable to hunting in fall than hens because: a) they
are noisier; b) they are more often alone, and lone birds tend to be easier to approach
than groups; and c) they are not as wary early in the season as females are. The relative
scarcity of males among bagged juveniles is harder to explain. When pursuing ptarmigan
in' autumn, I have noticed that young females tend to be in the rear of running flocks
and are more easily caught in nets (or shot) than other birds. Our information is not
conclusive, however. There may be more female chicks hatched than males, or their survival
during summer could be better-and this could vary annually.
The various involuntary biases that hunters show in their harvest of the several sex and
age classes of ptarmigan do not seem very strong. By and large, aggregate ratios for
the entire autumn hunting season indicate that hunters take birds in about the proportion
they occur in the population.
Source of Ptarmigan Harvested
One question of key importance is how big an area is supplying the ptarmigan shot by
Eagle Summit hunters. Common sense suggests that the idealized picture is one of
concentric rings around Eagle Summit, representing successively less important sources of
supply outward from the center (Appendix U). The data in Table 2, already used to
illustrate the small area worked by hunters, indicate a rough approximation of this idealized
situation. Birds banded close to the Highway are shot more often than ptarmigan caught
up to three miles from the road.
7
Table 5 . Sex and age of rock ptarmigan examined at the Steese checking station, 1968.
Birds of Known Age Birds of Known Sex Known Sex and Age
Total Total Total Total Ad . Ad. Juv. Juv.
Week Adults Juveniles Males Females M F M F
Aug. 10-16 47 80 54 38 31 15 2 2 22
Aug. 17-23 13 34 15 22 4 8 10 14
Aug. 24-30 11 10 34 29 4 7 7 3
00
Aug. 31-Sept. 6
Sept. 7-13
18
63
24
77
19
63
16
74
9
33
6
30
10
30
10
44
Sept. 14-20 57 74 63 63 3 3 24 30 39
Sept. 21-27 28 29 26 35 11 17 12 16
Sept. 28-0ct. 4
Oct. 5-11 21 21 21 2 1 10 11 11 10
Oct. 12-14 16 5 18 3 14 2 4 1
274 354 313 301 149 120 136 159
HUNTING PRESSURE
These data can be used to give an idea of the relative contribution to the hunter's bag
of each zone. For example, if the percentages of banded adult males shot are 23, 10
and 9 (Table 2) for Zones A, B, and C, then if unit densities of resident ptarmigan were
uniform throughout all zones, banded (and unhanded) resident males shot by hunters would
be in the proportion 23: 10: 9. Converting this to a percentage, 5 5 of every 100 resident
males would come from Zone A, 24 from B, and 21 from C. (Statistically, the difference
between A and B, or A and C, is significant at the 1 percent level). Among adult hens,
59 percent of harvested residents come from areas within one-half mile of the road, 22
percent from one-half to one mile away, and 19 percent from one to three miles away.
Similar figures for chicks are 62, 19, and 19 percent for zones A, B, and C.
Thus it appears that 55 to 60 percent of the resident ptarmigan that are shot lived within
one-half mile of an access road the summer before they were shot. Slightly .more than
20 percent come from an area one-half to one mile out, and slightly under 20 percent
spent the summer still farther away, up to three miles or so.
But this only pertains to ptarmigan living near the road. What proportion of the birds
taken by hunters canie from still farther away? Over the whole 1968 season, hunters
probably shot 60 to 65 of the 510 or so resident ptarmigan living (in summer) on the
Eagle Creek area. This figure was calculated from band returns and estimated proportions
of residents banded in 1968. The total known harvest from the study area, however,
was 278 birds (data from hunters reporting at the check station). Thus only 23 percent
of the birds shot had lived on the area in the summer. Many of the residents "escaped"
by moving farther away from the road during the customary wandering period in
September. Many new ptarmigan moved into the area from some distance away, providing
the bulk of the season's harvest.
As one would expect, relatively more resident ptarmigan are shot early in the season.
Fairly direct evidence comes from 1968 band returns. Hunters took 19 banded and 42
unhanded adults from August 10 to September 7. Since we banded 68 percent of the
resident adults on the area in 1968, nine of the 42 unhanded birds probably were also
residents, for a total of 28 out of the 61 shot. Thus, almost half of the adults (46%)
shot up to September 7, and perhaps the same percentage of juveniles, had lived at Eagle
Creek during the past summer.
In summary, my best estimate is that about three ptarmigan out of every four shot along
the Steese Highway were raised at least two miles from the Steese. Of those living within
the two-mile limit, 50 to 60 percent lived within one-half mile of the highway or one
of its access roads. We have no good idea how far the nonresident ptarmigan have moved
by the time they get close to the Steese. We have one instance of a bird, banded at
Eagle Creek, being shot the same year at Twelvemile Summit (15 air miles). I have recorded
only one case of a bird being shot eight miles from point of banding.
HUNTING PRESSURE
So far I have only described the kinds of ptarmigan shot by hunters: their sex, age,
total numbers per season and per bag, and residence status. The next step is to relate
numbers shot to numbers available.
Hunters provided the means to estimate hunting pressure at Eagle Creek through their
reports of banded birds. Before 1967 hunters were alerted to the presence of banded
9 /
ptarmigan by news releases and signs along the highway near Eagle Summit, but we
depended on their willingness to mail reports to us or to come into the office personally.
The bright colors of the bands insured that hunters would know that they had shot a
banded bird. Checking station operations in 1967 and 1968 made it easier for hunters
to report band recoveries, and I think we learned of more of the harvested banded birds
those years.
The calculations ignore pre-season mortality because no quantitative evaluation of this
factor is available. I judge that fewer than five percent of adults banded in summer
die before the hunting season. Losses of banded chicks probably were higher (perhaps
10 to 15 percent), but most chicks were banded two to three weeks before hunting,
so the time interval involved was short. (However, see Appendix III for data showing
no difference in the probability of getting a band return from chicks banded early and
from chicks banded late in the season.) Actual hunting losses certainly are higher than
my figures indicate, because of both pre-season mortality and nonreporting of bands.
Direct Returns from Adult Ptarmigan
A yearly summary of direct returns of banded rock ptarmigan, from 1960 to 1968, is
in Table 6. The first obvious feature of the data is that more of the males are shot
than females every year. As was discussed in an earlier section, the total harvest of adult
males is only slightly higher than that of adult females; it is when one considers local
or resident adults that the disproportionate harvest of cocks shows up. Part of the reason
is that adult males stay near their summer haunts throughout the hunting season, whereas
the old females migrate in late September. Appendix IV gives supporting evidence , showing
that hunters shoot banded males in similar numbers each month through October, but
that only six percent of the band returns from hens occur in October. The higher
vulnerability of cocks, based on their behavior, was discussed earlier. This contributes
to the higher rate of return of old males.
Table 6. Direct returns of banded adults, Eagle Creek, 1960-1968.
No. (%) of No. (%) of
Year Adult Males Adult Females
1960
1961
1962
1963
1964
1965
1966
1967
1968
Av.
2(8)
7(15)
5(7)
10(13)
7(14)
5(10)
13(50)
6(17)
13(27)
(16)
0
1(2)
1(1)
6(6)
1(2)
3(7)
10(14)
3(6)
10(16)
(6)
10
EFFECTS OF HUNTING ON PTARMIGAN
Another noticeable thing about the data is the variation in direct returns from year to
year. The only sustained trend seems to be a general increase in rate of return in recent
years. Among both sexes, direct returns from 1960 through 1964 were lower, on the
average, than returns from 1965-68. Most of the increase, I think, is due to changes
in our effort to get band returns. We made a special effort in 1966 to use news media
to let hunters know about the banding program. We also placed posters in all lodges
along the Steese Highway, and erected three signposts on and around Eagle Summit. By
chance, a herd of caribou wandered up to the Steese Highway in September, attracting
unusual numbers of hunters to the area. Thus, we could not measure the effect of the
informational campaign alone, but I am convinced that it did have some influence on
the number of unreported bands. The 1967 and 1968 check station operations likewise
improved reporting rates.
Direct Returns From Chicks
Yearly percentages (and numbers) of direct band returns from chicks are: 1960, 4% (3);
1961, 4% (5); 1962, 1% (1); 1963, 6% (11); 1964, 11% (6); 1965, 1% (2); 1966, 8%
(15); 1967, 9% (24); 1968, 5% (10). The mean annual rate for these years was 6%,
the same as for adult hens.
Considering that the estimates of direct returns probably are low, I think it is fair to
say that the average annual harvest of resident adult males, which approaches 20 percent,
could have noticeable effects on population size or makeup. There would appear to be
much less chance that hunting affects the adult female or juvenile segments of the
population. In the next section of this report I will explain what evidence we have to
show that hunting really does influence population attributes.
VISIBLE EFFECTS OF HUNTING ON PTARMIGAN POPULATIONS
Evidence From Eagle Creek
I looked for two kinds of effects: on total numbers in the breeding population, and
on the composition of the breeding stock.
Influence on abundance: If hunting is done mostly near roads, and if hunting influences
spring stocks, one would expect fewer pairs close to the Steese Highway and Eagle Creek
spur road than farther away. This effect should be especially noticeable following
particularly heavy fall hunting pressure. I tested these ideas by recording the number
of territorial cocks each year by zone, using the same zones as for measuring vulnerability
to hunting. The results are in Table 7.
Excluding areas above 3800 feet elevation, where ptarmigan rarely have territories, the
arbitrary zones A-C comprise 37, 34 and 29 percent, respectively, of the total study area.
Zone A had more than its share of territorial cocks in all years except 1965, when it
had as many as expected under a uniform distribution pattern, and 1968, when it had
fewer. Zone B had about as many as expected except possibly 1961, when only 27
percent of the territories were in that zone. The area farthest from the road, Zone C,
had consistently fewer territories than expected except in 1965 (when the percentage was
exactly as predicted from uniform distribution) and in 1968 when it had more than
expected.
11
Table 7. Number of territorial cocks by zone, 1960-1968.
Zone A Zone B Zone C
No. of Percent No. of Percent No. of Percent
Year Cocks o f Total Cocks of Total Cocks of Total
1960 38 42 33 37 17 21
1961 76 57 36 27 22 16
1962 69 41 65 38 36 21
1963 68 48 48 34 24 18
1964 55 50 37 34 17 16
1965 24 36 23 35 19 29
1966 35 44 24 30 21 26
1967 44 45 34 35 20 20
1968 28 27 39 37 38 36
Since Zone A averaged 6 percent more cocks than expected over the whole span of the
study, there is no basis for suggesting that hunting consistently lowered spring densities
close to the road. Even after the 1966 season, when at least half of the resident adult
males were taken in fall by hunters, there was no decrease in the proportion of territories
that zone contained next spring. Furthermore, the sharp drop in proportion and total
number of males observed in the spring of 1968 did not follow an unusually high fall
harvest.
An odd thing apparently did happen between 1967 and 1968 (Table 7): this was a sharp
drop in territorial cocks in Zone A while, at the same time, Zone B had slightly more
cocks and Zone C had almost twice as many. Furthermore, on two adjacent study areas
in upper Ptarmigan and Golddust creeks, each three miles or more from the Steese Highway,
spring densities of males rose 74 and 58 percent from 1967 to 1968. To me this indicates
that the drop occurring in Zone A was counter to the general upward trend in areas
away from the road. Circumstantial evidence points to spring hunting as being the culprit.
As I mentioned in the introduction to this report, no one shot ptarmigan at Eagle Summit
in March or April in the years 1960 to 1967 because the road was not passable. In
March 1968, however, the Department of Highways cleared snow from the entire Steese
Highway. Hunters were quick to take advantage of this. By early April a number of
ptarmigan-some banded ones, too-had been shot on the study area. The Regional Game
Supervisor issued a field announcement April 5, closing this area to ptarmigan hunting.
Department personnel patrolled the area on weekends for the rest of the month, after
which all legal bird hunting ceased throughout the Interior. Nevertheless there were
ptarmigan shot on the area throughout April and May, and even up to early June. The
total number taken is not known, but we do know that nesting hens and territorial cocks
were shot by people driving along the highway.
It seems very likely, therefore, that spring hunting did reduce the number of breeding
pairs along the road at Eagle Creek. One wonders just how this reduction was brought
about. In 1966 I had shot nine of 28 cocks counted May 18 in the Ptarmigan Creek
area, but when I returned 12 days later there were 29 males on the same area, indicating
12
EFFECTS OF HUNTING ON PTARMIGAN
that (in some years, at least) territorial males could be replaced by other birds from adjacent
areas even when pairs were firmly mated and eggs were being laid. So we are left with
a number of explanations to ponder:
1. There may not have been any II surplus II of extra males available in 1968 to replace
cocks shot by hunters;
2. There may have been some extra birds, but not enough;
3. There may have been enough extra birds, but their urge to take up territories may
have waned before illegal hunting stopped;
4. It may have been the shooting of hens, not cocks, which was critical; we know nothing
about the presence of 11 surplus" hens available to replace lost breeders.
One further thought may be useful: Female ptarmigan are moving back to breeding areas
throughout April, and therefore hens shot on a given hill in April are likely to be transients.
The critical hunting at Eagle Creek in 1968 might have occurred in May.
The main point, of course, is that whereas fall hunting has not appeared to influence
subsequent spring densities, our single experience with hunting in April and May justifies
a closer look at spring hunting as it may affect breeding densities.*
Influence on composition of breeding populations: Our knowledge of the relative
proportion of males and females in spring is not very good because it is hard to get
a direct count of hens. In our spring census we usually see three cocks for every hen
we find, although intensive work later in summer invariably turns up many more females.
As a rule our studies usually suggest that there are slightly more males than females (perhaps
five percent more) most years when nesting begins. In 1961, and again in 1967, there
seemed to be as many hens as cocks in late May. However, we do not have good enough
data to make a careful test for a relationship between hunting and spring sex ratios.
We can distinguish yearling males and females from older ptarmigan in spring by the amount
of dark pigment on their outer wing feathers (Weeden and Watson, 1967). This provides
the opportunity to estimate age ratios in the breeding population, by sex. Since we know
that fewer adult females (especially local or "resident" females) than adult males are shot
at Eagle Creek, we have a two-way test of the question as to whether hunting affects
spring age ratios: I) Are there relatively more yearling ptarmigan on territories close
to the road system than farther away? and 2) Are there more yearlings among males
than among females?
Once again it is handy to use the "zoning" method to test the first question. Summarizing
all captures of adults in the nine-year study (Table 8), I find that .in both cocks and
hens there tend to be more first-year birds close to the highway (Zone A) than farther
away. As was true when we analyzed band returns (Table 2), the main difference is
between Zone A and Zone B, not between Zones B and C. The drop in percentage
* 1969 brought confirmation of this point. The Highway opened April 17, simultaneously
with an annoucement closing Eagle Summit to ptarmigan hunting. Illegal hunting persisted
to early June. Pairs seen near the Highway in April "disappeared" steadily.
13
Table 8. Age of adults by zone of residence, 1960-1968. *
Zone First-Year Males 2+ Males First-Year Hens 2+ Hens
A 86 (71 %) 35 122 (56%) 97
B 56 (53%) 49 62 (45%) 77
C 44 (49%) 46 72 (46%) 83
Pooled Sample 186 (59%) 130 276 (52%) 257
* Mainly from 1963 to 1968, because before 1963 the only way we could tell the age
of a mature ptarmigan was through banding.
of yearlings is greater from Zone A to Zone B among males (18 percent) than females
(11 percent), which is what would be expected from the fact that more adult cocks are
shot than adult hens.
The second question is whether there are more yearlings among males than females. The
answer seems to be yes. In every zone, there were more young birds among cocks than
hens. The difference became progressively less ( 15 to 8 to 3 percent in Zones A-C,
respectively) the farther from a road the sample was taken. We need, but do not have,
a sample from five miles or more from a road, to see whether the difference disappears
in essentially unhunted populations.
Further evidence that hunting is the cause of the observed differences in age ratios was
obtained in 1966 through 1968. In the fall of 1966 hunters reported shooting slightly
over half of the adult males banded that year. They returned only 15 percent of the
banded adult hens, however. The following spring 82 percent of all cocks caught were
yearlings, but only 60 percent of the sample of breeding hens were first-year birds. Hunting
pressure was much lighter in the fall of 1967, but unusual spring hunting occurred in
1968, as discussed previously. Once again, more of the cocks we caught in 1968 (86
percent) were yearlings than of the hens (57 percent).
It seems clear that hunting does influence age ratios among breeding ptarmigan. The
question is how this effect is brought about. The best explanation may be that in an
unhunted population old birds dominate the competition for breeding space and exclude
some young ptarmigan. This competition may take place in autumn, as Watson (1967)
found for red grouse in Scotland, and the birds that get the good pieces of ground then
may survive better through the winter than birds that get poorer ground or none at all.
Thus, when hunters shoot these established birds, either in fall or spring, there is a
"vacancy" available for a less aggressive bird to move into. Our banding work at Eagle
Creek showed that older male and female ptarmigan are very likely to return to their
former breeding grounds if they live through the winter, whereas the first-year birds move
around. It is logical to expect that old birds, if shot, would be replaced by young birds.
This would skew the age ratio toward yearlings in hunted populations.
Evidence From Experiements
The things we can learn about the effects of hunting on ptarmigan numbers are limited,
at Eagle Creek, by the fact that the Department does not control the number of hunters
14
MANIPULATING THE HARVEST
or the proportion of birds shot. To get around this limitation, we established two areas
well away from the Steese Highway, but in the general vicinity of Eagle Summit, where
experimental hunting could be done. On one area of about five square miles (Ptarmigan
Creek) we decided to make spring censuses in 1967, 1968, 1969, and 1970. Each fall,
1967 through 1969, 40 percent of the estimated autumn population would be shot by
Division of Game biologists. Spring counts would be made in 1967 through 1970 in
the other area (Golddust Creek, four square miles), but no ptarmigan would be shot there.
The number of birds to be shot at Ptarmigan Creek was determined by applying the same
rate of summer population gain to the spring densities observed there, as was discovered
each year during studies at Eagle Creek.
The removal aspect of the experiment was accomplished successfully,' mainly through
shooting in mid-August and early September. The four spring censuses were made as
planned. The results (Table 9) suggest strongly that the controlled-level hunting had no
bearing on subsequent spring populations. The conclusion to be drawn from the work
is that when hunters shoot birds in autumn from a small area surrounded by productive
but unhunted habitat, removal of 40 percent of the birds does not change the normal
trend in populations. If anything, the data suggest that ptarmigan numbers rose faster
between 1967-68 on the shot area than on areas that experienced no hunting or lesser
hunting pressure.
MANIPULATING THE HARVEST
Ptarmigan hunting at Eagle Summit currently results in annual harvests on the order of
5 to 20 percent of the fall population. This modest harvest is limited by: a) limited
participation in bird hunting by Alaskan hunters; b) late-fall closure of the Steese Highway;
and c) slight use of snowmobiles. Any or all of these elements could change, and with
that in mind I will discuss potential management problems.
Excessive Harvest
At Eagle Summit there are usually as many or more ptarmigan per unit area in May
within one-half mile of the Steese Highway as in the area one-half to two miles off the
road. If counts showed lower densities close to the highway, and especially if this was
coupled with comparatively high proportions of first-year birds near the road, managers
would be warned of excessive harvests the previous year.
One of the first steps to consider would be to open the season later in the fall. Openings
of September 1 or September 10 would not reduce the total harvest greatly, but would
result in significantly fewer local birds being taken. The sparing of resident adults might
result in better spring populations the next year. This step could be effective only if
no hunting was allowed in spring, however. Currently the season remains open until
April 30. March closures would ensure that the pressure was taken off local breeding
stock. If the season closed by March 1, few territorial cocks would have been shot.
A closure on March 30 would allow some males to be shot on territories, but their· places
very likely would be taken in April and May by yearlings. Few females would be taken,
since hens begin to show up in breeding habitats · about the first of April.
Another approach might be to retain long seasons, but to prohibit hunting along the road.
A one-quarter-mile closure would effectively reduce harvests, if enforced, because it would
dampen the enthusiasm of a majority of erstwhile ptarmigan hunters who shoot birds
only if they see them from the road.
15
Table 9. Spring counts on three units of ptarmigan habitat near Eagle Summit, Steese Highway, 1967-70.
No. Territorial Males
Area Sq. Miles Treatment 1967 1968 1969 1970
-O'\
Golddust Creek
Ptarmigan Creek
4
5
No hunting
40% shot in fall 1967-69
60*
57
95
99
81
98
81
94
Eagle Creek 15 Uncontrolled hunting 98 120** 113 102
* Expanded from a count of two-thirds of the area.
** Adjusted to compensate for effects of illegal spring hunting.
SUMMARY
Overharvest of Males Only
If the Steese were maintained March 1 to November 30, up to 50 percent more cocks
than hens might be shot even if hunting pressure remained quite light. If managers felt
this situation needed correcting, a number of choices are available. First, the bag limit
could be reduced after October 1 to five per day. Second, the season could be closed
March 1. Third, the season could be closed in the month of October only, allowing
good harvests of both sexes in August and September and allowing snowmobile enthusiasts
to enjoy winter hunting in November and March.
Decreased Recreational Quality
Quality recreation is a personal matter, of course, but game managers do have an obligation
to foster hunting methods that have general support from the public. Biologists know
that allowing people to hunt ptarmigan by throwing ptarmigan eggs in the air and shooting
them could be controlled so as not to "hurt the population" of ptarmigan, but there
are tacit sanctions against that sort of hunting that we all perceive and obey.
Present regulations are very permissive-and should be as long as people stay out of each
other's hair. Increased crowding could cause some distasteful situations to arise, however,
and we should be prepared to meet or forestall them. Some suggestions follow that can
be used singly or in combinations that different situations demand:
1. Urge or require the use of dogs.
2. Urge or require the use of shotguns (in preference to rifles).
3. Make people walk by closing areas close to roads.
4. To forestall complaints about ptarmigan being too young, open seasons on
September 1 (when chicks are 75 to 80 percent of adult weight most years) or as late
as September 30 (chicks are 90 percent or so of adult weight).
5. Encourage skis or snowshoes in preference to snowmobiles.
6. Reduce crowding by a) providing access to new areas, b) publicizing little-known
areas, or c) weekend permit systems to limit participation on days of greatest crowding.
SUMMARY
In 1927 the Steese Highway connected Fairbanks with Circle City, opening up several
pieces of alpine country to hunters. The popularity of these areas reached a peak about
1950. Since Department studies began in 1959 ptarmigan country has been relatively
uncrowded with hunters, although rumors of good caribou hunting have occasionally and
temporarily increased bird-hunting pressure. Fall hunting has begun August 10 or 20
in the last decade, and had been brought to an early close by official highway closures
or drifting snow in October. Only twice-in 1968 and 1969--did the highway open up
in spring early enough to allow hunters to travel to Eagle Summit before the season closed
April 30.
At least half of the ptarmigan shot are taken on weekends. Half of the hunters come
up the highway with plans to hunt birds, although the best way to identify a ptarmigan
17
hunter is by looking in his game bag. Most hunters walk only a shortdistance to get
ptarmigan, which means that a bird summering within one-half mile of the Steese Highway
is about twice as likely to be shot as one living farther away. Few snowmobiles were
in use through 1969 in the Eagle Summit area.
Most years about 400 to 1000 rock ptarmigan are shot along the upper Steese Highway,
or about 14 to 36 birds per square mile of accessible habitat. Successful parties of hunters
(mean of two hunters per party) get from 4 to 11 ptarmigan per trip. Very few
people-about 5 percent in 1968-shoot a bag limit of 20 ptarmigan per day. Ptarmigan
of different sex and age classes are shot in nearly the proportion in which they occur
in the population, although an unconscious selection of adultmales occurs, Most of the
ptarmigan that hunters shoot in fall .are transients, having moved three miles or more
before getting close to the Steese Highway. In 1968 only 23 percent. of the; ptarmigan
harvested up ·to October 13 had lived, that summer, within three miles of the road. Up
to 50 percent of the birds · shot in August are local residents, however.
Upwards of 20 percent of the old cocks living at Eagle Creek are shot each fall, although
one year ( 1966) at least half were shot. · Hunting pressure on adult hens and local chicks
is lighter,-averaging 6 percent. Analyses of spring distribution and densities of breeding
pairs suggested that this. hunting pressure has had little effect on subsequent breeding
numbers, but that the removal of old males (and their replacement by surplus yearlings)
often skews the age distribution among males. Only in two years, 1968 and 1969, did
we have evidence that hunting reduced breeding densities along the road. This was probably
due to spring hunting (April and May) rather than fall hunting.
By comparing spring populations in an unhunted area with those in an area from which
40 percent of the fall population was shot in 1967 and 1968, we learned that spring
breeding stocks were unaffected by hunting pressure of that magnitude.
A variety of techniques are available to the game manager to manipulate harvests or
maintain the quality of recreation derived from ptarmigan hunting at Eagle Summit. These
are discussed in the text.
.REFERENCES CITED
Watson, Adam. 1967. Population control by territorial behavior in red grouse. Nature,
215: 1274-1275.
Weeden, Robert and Adam Watson. 1967. · Determining the age of rock ptarmigan in
Alaska and Scotland. · Jour. Wildt Mgmt. 31(4):825-826.
18
APPENDIX
APPENDIX I
a____.....1/'-"2'-----11 mile
i I 1
1N
ZONES USED IN MEASURING THE EFFECTS OF HUNTING ON LOCAL PTARMIGAN
POPULATIONS' (Hatched areas above 3700' not used by territorial cocks.)
19
--
APPENDIX II
6-8 miles
4-6 miles
2-4 miles
1-2 miles
1/2-1 mile
J/2 mile
...111....,..s...t...,ee=se___, 14
( t11ghway 0
N76%
PERCENTAGE OF PTARMIGAN IN HUNTER'S BAGS FROM VARIOUS DISTANCES AWAY FROM THE
STEESE HIGHWAY.
APPENDIX
APPENDIX III
It would seem logical that because of summer mortality, relatively few chicks from groups
banded early in the summer would be reported by hunters. However, a summary of
four years of data (1963, 1966, 1967, 1968) does not support this hypothesis.
Days From Banding to Number Number Percent
Start of Hunting Banded Shot Shot
0-10 121 10 7
11-20 231 13 6
21-30 .311 22 7
31-40 165 10 6
41-50 62 5 8
Chick mortality from hatching to early August has varied between 10 and 40 per cent.
A good fraction of this mortality occurs in the first two weeks, before chicks are big
enough to band. Nevertheless it is surprising that there isn't even a small difference in
hunter returns, related to the time interval between banding and hunting.
APPENDIX IV
Proportion of Banded Adult Ptarmigan Shot
at Eagle Summit, by Month and Sex
1960-1968
No. Banded No. (%) No. Banded No. (%)
Males Shot Males Shot Females Shot Females Shot
Month (uncorrected) (corrected)* ( uncorrected) (corrected)*
August 22 37 (28) 25 42 (49)
September 45 45 (34) 38 38 (45)
October 34 51 (38) 3 5 (6)
November 2 0
* Season opened on August 10 in five years, on August 20 in four years; there were,
on the average, 18 days of hunting in August. Hunting occurred throughout September
each year. Road Maintenance ceased most years on or about October 10. I have arbitrarily
used an average of 20 days of hunting in the Eagle Summit area in October. Thus, August
and October data are increased to estimate number of returns if a full 30 days were
available each month. The two cocks shot in November are ignored.
21