HomeMy WebLinkAboutTask 32 continous water temp investigations est 1984.... "'"' - .....TK 1425 .88 A6S no.3508 ALASKA DEPARTMENT OF FISH AND GAME SUSITNA HYDRO AQUATIC STUDIES REPORT SERIES ALASKA POWER AUTHORITY 334 W.FIFTH AVE. ANCHORAGE,ALASKA """l I I -n<; /if:26 .~6 A-lo<t ALASKA DEPARTMENT OF FISH AND GAME SUSITNA HYDRO AQUATIC STUDIES TASK 32 SUPPORT TECHNICAL REPORT CONTINUOUS WATER TEMPERATURE INVESTIGATIONS by:Theresa Keklak and Timothy Quane Prepared for: ARLIS '.Alaska Resources LIbrary &lnfonnation ServICes Anchorage.Alaska "'"TABLE OF CONTENTS TABLE OF CONTENTS...........................................i LIST OF FIGURES ..............•...........'...... . . . . . . ...... .xi r LIST OF TABLES .. 1.0 INTRODUCTION . iii 1 1.1 Background.......................... ....... .. .. .. .................. ........ ...... ....1 1.2 Objectives...........................................1 2.0 METHODS.................................................2 2.1 Site Selection.......................................2 2.2 Field Dat~Collection................................2 2.2.1 Peabody Ryan Temperature Recorder................2 2.2.2 Omnidata Temperature Recorder (Datapods).........5 2.3 Data Analysis........................................6 2.3.1 Peabody Ryan Temperature Recorder (Thermographs).6 2.3.2 Omnidata Temperature Recorder (Datapods).........7 3.0 RESULTS.................................................7 3.1 Table 2 -Susitna River index of temperatures recorded in mainstem and tributary habitats during the 1984 open water season.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 ""'1 ! ('t) o ('t).... vv ooo ll) ll) '"('t) ('t) 3.2 Tables 3 to 22 -Daily and monthly minimum,mean and maximum temperatures recorded at mainstem Susitna River sites during the 1984 open water season ••.........•.• 3.3 Tables 23 to 36 -Daily and monthly minimum,mean and maximum temperatures recorded at tributary sites during the 1984 open water season •........•..•..•....•..~... 3.4 Tables 37 to 56 -Water year weeekly minimum,mean,and maximum temperatures recorded at mainstem Susitna River sites during the 1984 open water season ..•....•....... 13 105 173 TABLE OF CONTENTS (cant.) 3.5 Tables 57 to 70 -Water year weeekly minimum,mean,and maximum temperatures recorded at tributary sites during the 1984 open water season .....................•..... 3.6 Table 71 -Water temperature profiles of continuous temperature monitoring sites located in the Susitna River Basin during the 1984 open water season ......•.•..•.. 3.7 Figures 2 to 16 -Mean daily temperatures recorded at Mainstem Susitna River sites during the 1984 open water season III .. ~ 194 ~\ 209 ~ 213 3.8 Figures 17 to 28 -Mean daily temperatures recorded at tributary sites suring the 1984 open water season....229 3.9 Figures 29 to 45 -Site maps depicting locations of study areas in mainstem and tributary habitats during the 1984 open water season "III....242 LITERATURE CITED •..•.•"..o.................................265 i i - """ ..... - - -LIST OF TABLES Table 1. Table 2. Table 3. Continuous temperature monitoring stations located in the Susitna River Basin during the 1984 open water season in support of Tas k 32 .. ADF&G Susitna River index of temperatures recorded in mainstem and tributary habitats during the 1984 open water season . Ryan temperature recorder data summary: surface water temperatures (C)recorded at Mainstem Susitna River at RM 18.5,GC 3 9 S16N07W15DCD.................................14 - Table 4. Table 5. Table 6. Table 7. Table 8. Table 9. Table 10. Ryan temperature recorder data summary: surface water temperatures (C)recorded at Mainstem Susitna River above the Yentna River,RM 29.5,GC S17N06W07CAD •...•...•....• Datapod temperature recorder data summary: surface water temperatures (C)recorded at Mainstem Susitna River above the Yentna River,RM 29.5,GC S17N06W07CAD ..•........... Ryan temperature recorder data summary: surface water temperatures (C)recorded at Mainstem Susitna River above the Deshka River,RM 41.1,GC S19N06W26SBC ..•••..•...••. Ryan temperature recorder data summary: surface water temperatures (C)recorded at Mainstem Susitna River above Kashwitna River, RM 61.2,GC S31N05W13ABA •..................•• Ryan temperature recorder data summary: surface water temperatures (C)recorded at Mainstem Susitna River at Parks Highway Bri dge Center Span -Site 4,RM 83.9,GC S24N05W15BAD .......•......................... Ryan temperature recorder data summary: surface water temperatures (C)recorded at Mainstem Susitna River above the Parks Highway Bridge,RM 86.9,GC S24N05W01BCD ..... Ryan temperature recorder data summary: surface water temperatures (C)recorded at Mainstem Susitna River at Tal"keetna Fishwheel Camp,RM 103.0,GC S27N05W26DDD .•..•..•..•.•. iii 20 25 27 34 40 41 45 LIST OF TABLES (cont.) - Table 11. Table 12. Table 13. Table 14. Table 15. Table 16. Table 17. Table 18. Table 19. Table 20. Datapod temperature recorder data summary: intragravel and surface water temperatures (C)recorded at Mainstem Susitna River at LRX 9 -Site 3,RM 103.5,GC 27N05W26ADD .......•. Ryan temperature recorder data summary~ surface water temperatures (C)recorded at Mainstem Susitna River at Curry Fishwheel Camp,RM 120.7,GC S27N04W10CBA .•............ Datapod temperature recorder data summary: intragravel and surface water temperatures (C)recorded at Mainstem Susitna River at LRX 29 -Site 3,RM 125.9,GC S30N05W19DAB ......• Ryan temperature recorder data summary: surface water temperatures (C)recorded at Mainstem Susitna River at LRX 53,RM 140.1, GC S31NI1WIOAAC .....•...............•........ Datapod temperature recorder data summary: i ntragrave 1 and surface water temperatures (C)recorded at Mainstem Susitna River at LRX 56,RM 142.1,GC S31N11W36BCD ............•... Ryan temperature recorder data summary: surface water temperatures (C)recorded at Mainstem Susitna River above Portage Creek, RM 148.9,GC S32N10W16ACB .....•.............. Ryan temperature recorder data summary: surface water temperatures (C)recorded at Mainstem Susitna River above Fog Creek -Site 1,RM 176.8,GC S31N06W15BAC ............•..•. Ryan temperature recorder data summary: surface water temperatures (C)recorded at Mainstem Susitna River above Fog Creek -Site 2,RM 176.8,GC S31N06W15BAC .........•....... Datapod temperature recorder data summary~ surface water temperatures (C)recorded at Mainstem Susitna River above Fog Creek -Site 2,RM 176.8,GC S31N06W16BAC .....•..•..••..• Ryan temperature recorder data summary: surface water temperatures (C)recorded at Mainstem Susitna River above Fog Creek -Site 3,RM 176.8,GC S31N06W15BAC .........•....... iv 51 57 62 68 74 79 84 88 93 94 - - - LIST OF TABLES (cont.) Table 21. Table 22. Ryan temperature recorder data summary: surface water temperatures (C)recorded at Mainstem Susitna River at Watana Dam Site,RM 184.2,GC S32N05W33BDB .............•..•...... Datapod temperature recorder data summary: surface water temperatures (C)recorded at Mainstem Susitna River at Watana Dam Site,RM 184.2,GC S32N05W33BDB ..•.......•.........•.• 96 102 Table 23. Table 24. Table 25. Ryan temperature recorder data summary: surface water temperatures (C)recorded at the Yentna River -Site 2,RM 281.0,TRM 4.0, GC S18N07W28ABC..............................106 Datapod temperature recorder data summary: surface water temperatures (C)recorded at the Yentna River -Site 2,RM 28.0,TRM 4.0, GC S18N07W28ABC..............................111 Ryan temperature recorder data summary: surface water temperatures (C)recorded at the Deshka River,RM 40.6,TRM 3.0,GC S19N06W23BDC.................................114 Table 26. Table 27. Datapod temperature recorder data summary: surface water temperatures (C)recorded at Deshka River,RM 40.6,TRM 3.0,S19N06W23BDC. Ryan temperature recorder data summary: surface water temperatures (C)recorded at the Kashwitna River,RM 60.9,TRM 0.1,GC 120 S21N06W13AAC.................. ........•......121 - Table 28. Table 29. Table 30. Ryan temperature recorder data summary: surface water temperatures (C)recorded at the Talkeetna River -Site 3,RM 97.2,TRM 4.0,GC S26N04W16CB~•...•.......•.....••..•.• Ryan temperature recorder data summary: surface water temperatures (C)recorded at the Chulitna River -Site 5,RM 98.6,TRM 11.0,GC S27N05W05ABC .....•..••••..•••.•••.•• Datapod temperature recorder data summary: surface water temperatures (C)recorded at Portage Creek -Site 2,RM 148.8,TRM 0.2,GC 127 133 S32NIOW25ADC.• •• . •• . •. • ••• . • •. •• . . . . . •. . • . . • .139 Table 31.Ryan temperature recorder data summary: surface water temperatures (C)recorded at Fog Creek,RM 176.7,TRMO.1,GC S31N06W15DBB •.•.•...•.........•.••.••...••••. v 145 LIST OF TABLES (cont.) Table 32. Table 33. Ryan temperature recorder data summary: surface water temperatures (C)recorded at Tsusena Creek,RM 181.8,TRM 0.1,GC S32N06W36ADB D..........151 Ryan temperature recorder data summary: surface water temperatures (C)recorded at Deadhorse Creek,RM 120.9,TRM 1.0 GC S29N04W14BCB.. . . . . . . . • . . •. •• . . . . . . . . . . . . . . . . .157 Tabl e 34. Table 35. Table 36. Table 37. Table 38. Table 39. Table 40. Datapod temperature recorder data summary: intragravel water temperatures (C)recorded at Fourth of July Creek and Pl ume -Site 1. RM 131.1,GC S30N03W03DAC ..............•..... Datapod temperature recorder data summary: intragravel and surface water temperatures (C)recorded at Indian River -Site 3,RM 138.6,TRM 0.2,GC S31N02W09CAB . Datapod temperature recorder data summary: intragravel and surface water temperatures (C)recorded at Indian River -Site 4,RM 138.6,TRM 0.2,GC S31N02W09CAB ......•....... Weekly minimum,mean,and maximum surface water temperatures (C)recorded at Mainstem Susitna River at RM 18.5,GC S16N07W15CDC. Values were obtained from temperatures measured at two-hour intervals by a Ryan temperature recorder •........................ Weekly minimum,mean,and maximum surface water temperatures (C)recorded at Mainstem Susitna River above the Yentna River,RM 29.5,GC S17N06W07CAD.Values were obtained from temperatures measured at two-hour intervals by a Ryan temperature recorder ..... Weekly minimum,mean and maximum surface water temperatures (C)recorded at Mainstem Susitna River above the Yentna River,RM 29.5,GC S17N06W07CAD.Values were obtained from temperatures measured at six-hour intervals by a datapod temperature recorder .. Weekly minimum,mean,and maximum surface water temperatures (C)recorded at Mainstem Susitna River above the Deshka River,RM 41.1,GC S19N06W26CBC.Values were obtained from temperatures measured at two-hour intervals by a Ryan temperature recorder ..... vi 164 166 171 174 175 176 177 ..... - - ..,., - LIST OF TABLES (cant.) Table 41. Table 42 Table 43 Table 44 Table 45 Table 46 Table 47 Weekly mlnlmum,mean,and maximum surface water temperatures (C)recorded at Mai nstem Susitna River above the Kashwitna River,RM 61.2,GC S21N05W13ABA.Values were obtained from temperatures measured at two-hour intervals by a Ryan temperature recorder ...•. Weekly minimum,mean,and maximum surface water temperatures (C)recorded at Mai nstem Susitna River at the Parks Highway Bridge Center Span Site 4,RM 83.9,GC S24N05W15BAD.Values were obtained from temperatures measured at two-hour i nterva 1s by a Ryan temperature recorder ..•.......•...• Weekly minimum,mean,and maximum surface water temperatures (C)recorded at Mainstem Susitna River above the Parks Highway Bridge, RM 86.9,GC S24N05WO 1BCD.Va 1ues were obtained from temperatures measured at two-hour intervals by a Ryan temperature recorder . Weekly minimum,mean,and maximum surface water temperatures (C)recorded at Ma i nstem Susitna River at Talkeetna Fishwheel Camp,RM 103.0,GC S27N05W26DDD.Values were obtained from temperatures measured at two-hour intervals by a Ryan temperature recorder ..•.. Weekly minimum,mean,and maximum surface water temperatures (C)recorded at Mainstem Susitna River at LRX 9 -Site 3,RM 103.5,GC S27N05W26ADD.Values were obtained from temperatures measured at si x-hour i nterva 1 s by a datapod temperature recorder .......•.... Weekly minimum,mean,and maximum surface water temperatures (C)recorded at Mainstem Susitna River at Curry Fishwheel Camp,RM 120.7,GC S27N04W10CBA.Values were obtained from temperatures measured at two-hour intervals by a Ryan temperature recorder ..•.. Weekly minimum,mean,and maximum intragravel and surface water temperatures (C)recorded at Mainstem Susitna River at LRX 29 -Site 3, RM 125.9,GC S30N03W19DAB.Values were obtained from temperatures measured at si x-hour i nterva 1s by a data pod temperature recorder . vii 178 179 180 181 182 183 184 LIST OF TABLES (cont.) Table 48 Table 49 Table 50 Table 51 Table 52 Table 53 Table 54 Table 55 Weekly minimum,mean,and maximum surface water temperatures (C)recorded at Mainstem Susitna River at LRX 53,RM 140.1,GC S31N11W10AAC.Values were obtained from temperatures measured at two-hour i nterva 1s by a Ryan temperature recorder .•............. Weekly minimum,mean,and maximum intragravel and surface water temperatures (C)recorded at Mainstem Susitna River at LRX 56,RM 142.1,GC S31N11W36BCD.Values were obtained from temperatures measure at six-hour intervals by a datapod temperature recorder .. Weekly minimum,mean,and maximum surface water temperatures (C)recorded at Mainstem Susitna River above Portage Creek,RM 148.9, GC S32N10W16ACB.Values were obtained from temperatures measured at two-hour i nterva 1 s by a Ryan temperature recorder ....•.•...•.•.. Weekly minimum,mean,and maximum surface water temperatures (C)recorded at Mai nstem Susitna River above Fog Creek -Si te 1,RM 176.8,GC S31N06W15BAC.Values were obtained from temperatures measured at two-hour intervals by a Ryan temperature recorder ..... Weekly minimum,mean,and maximum surface water temperatures (C)recorded at Mainstem Susitna River above Fog Creek -Site 2,RM 176.8,GC S31N06W15BAC.Values were obtained from temperatures measured at two-hour intervals by a Ryan temperature recorder •.... Weekly minimum,mean,and maximum surface water temperatures (C)recorded at Mainstem Sus i tna Ri ver above Fog Creek -Site 2,RM 176.8,GC S31N06W15BAC.Values were obtained from temperatures measured at two hour intervals by a datapod temperature recorder •. Weekly minimum,mean,and maximum surface water temperatures (C)recorded at Mai nstem Sus itna Ri ver above Fog Creek -Site 3,RM 176.8,GC S31N06W15BAC.Values were obtained from temperatures measured at two-hour intervals by a Ryan temperature recorder ..•.. Weekly minimum,mean,and maximum surface water temperatures (C)recorded at Ma instem Susitna river at Watana Dam Site,RM 184.2, GC S32N05W33BDB.Va 1ues were obtained formtemperaturesmeasuredattwo-hour intervals by a Ryan temperature recorder ......•........... viii 185 186 187 188 189 190 191 192 - - - - - - -LIST OF TABLES (cont.) ..... -- ,""'; ! Table 56 Table 57 Table 58 Table 59 Table 60 Table 61 Table 62 Table 63 Weekly mlnlmum,mean and maximum surface water temperatures (C)recorded at Ma instem Susitna River at Watana Dam Site,RM 184.2, GC S3 2N05W33BDB.Val ues were obta i ned from temperatures measured at six-hour ·intervals by a datapod temperature recorder .•.....•.... Weekly minimum,mean,and maximum surface water temperatures (C)recorded at the Yentna River Site 2,RM 28.0,TRM 4.0,GC S18N07W28ABC.Values were obtained from temperatures measured at two-hour i nterva 1s by a Ryan temperature recorder .•.........•... Weekly minimum,mean,and maximum surface water temperatures (C)recorded at the Yentna River,RM 28.0,TRM 4.0,GC S18N07W34DBC. Values were obtained from temperatures measured at six-hour intervals by a datapod temperature recorder ..•.....•.....•.......•.. Weekly minimum,mean,and maximum surface water temperatures (C)recorded at the Deshka River,RM 40.6,TRM 3.0,GC S19N06W23BDC. Values were obtained from temperatures measured at two-hour intervals by a Ryan tempera ture recorder .......•.............•... Weekly minimum,mean and maximum surface water temperatures (C)recorded at the Deshka River,RM 40.6,TRM 3.0,GC S19N06W23BDC. Values were obtained from temperatures measured at si x-hour i nterva 1s by a data pod temperature recorder ..•..•....•..••.•....•... Weekly minimum,mean,and maximum surface water temperatures (C)recorded at the Kashwitna River,RM 60.9,TRM 0.1,GC S21N05W13AAC.Values were obtained from temperatures measured at two-hour interval s by a Ryan temperature recorder .....••••..••.. Weekly minimum,mean,and maximum surface water temperatures (C)recorded at the Talkeetna River -Site 3,RM 97.2,TRM 4.0. GC S26N04W16BCA.Values were obtained from temperatures measured at two-hour i nterva 1s by a Ryan temperature recorder ..•.•••.•....•• Weekly minimum,mean and maximum surface water temperatures (C)recorded at the Chulitna River -Site 5,RM 98.6,TRM 11.0, GC S27N05W05ABC.VaJ ues were obtained fromtemperaturesmeasureattwo-hour i nterva I s by a Ryan temperature recorder ...•.•........• ix 193 195 196 197 198 199 200 201 TABLE OF CONTENTS (cont.) Table 64 Table 65 Table 66 Table 67 Table 68 Table 69 Table 70 Table 71 Weekly minimum,mean,and maximum surface water temperatures (C)recorded at Portage Creek -Site 2,RM 148.8,TRM 0.2,GC S32N01W25ADC.Values were obtained from temperatures measured at one-hour i nterva 1s by a datapod depth/temperature recorder . Weekly minimum,mean,and maximum surface water temperatures (C)recorded at Fog Creek, RM 176.7,TRM 0.1,GC S31N06W15DBB.Values were obtai ned from temperatures measured at two-hour intervals by a Ryan temperature recorder .. Weekly mi nimum,mean,and maximum surface water temperatures (C)recorded at Tsusena Creek,RM 181.8,TRM 0.1,GC S32N06W36ADB. Values were obtained from temperatures measured at two-hour intervals by a Ryan temperature recorder ....•..............•..... Weekly minimum,mean,and maximum surface water temperatures (C)recorded at Deadhorse Creek,RM ·120.9,TRM 1.0,GC S29N04W14BCB. Values were obtained from temperatures measured at two-hour intervals by a Ryan temperature recorder ....•..•....•....•..•.... Weekly minimum,mean and maximum intragravel water temperatures (C)recorded at Fourth of July Creek and Plume -Site 1,RM 131.1,GC S30N03W03DAC.Values were obtained from temperatures measured at si x-hour interval s by a data pod temperature recorder ....•...•... Weekly minimum,mean,and maximum intragravel and surface water temperatures (C)recorded at Indian River -Site 3,RM 138.6,TRM 0.2, GC S31N02W09CAB.Values were obtained from temperatures measured at six-hour intervals by a datapod temperature recorder ••.••..•.... Weekly minimum,mean,and maximum intragravel and surface water temperatures (C)recorded at Mainstem Susitna River at Indian River - Site 4,RM 138.6,TRM 0.2,GC S31N02W09CAB. Values were obtained from temperatures measured at six-hour i nterva 1s by a datapod temperature recorder .•.....•..•.....••...•... Water temperatures profiles of continuous temperature monitori ng sites located in the Susitna River Basin during the 1984 openwaterseason.. x 202 203 204 205 206 207 208 210 - -. - - - - LIST OF FIGURES - Figure 1. Fi gure 2. Figure 3. Figure 4. Figure 5. Figure 6. Figure 7. Fi gure 8. Locati ons of temperature monitori ng stati ons in mainstem and tributary habitats during the 1984 open water season in support of Task 32 . Mean daily surface water temperature recorded at Mainstem Susitna River (RM 18.5)during the 1984 open water season .••..•.....••.••................ Mean daily surface water temperature recorded at Mainstem Susitna River above the Yentna River (RM 29.5)during the 1984 open water season ....•..... Mean daily surface water temperature recorded at Mainstem Susitna River above the Deshka River (RM 41.1)during the 1984 open water season ...•....•. Mean daily surface water temperature recorded at Mainstem Susitna River above the Kashwitna River (RM 61.2)during the 1984 open water season . Mean daily surface water temperature recorded at Mainstem Susitna River at Parks Highway Bridge Center Span-Site 4 (RM 83.9)during the 1984 open water season .. Mean daily surface water temperature recorded at Mainstem Susitna River above the Parks Highway Bridge (RM 86.9)during the 1984 open water season .. Mean daily surface water temperature recorded at Mainstem Susitna River at Talkeetna Fishwheel Camp (RM 103.0)during the 1984 open water 4 214 215 216 217 218 219 Fi gure 9. sea son.... .. .. .. .. ..•.. .. .. .. .. .. .. .. .. ..•.. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ...... .. ........220 Mean daily surface and intragravel water temperatures recorded at Mainstem Susitna River at LRX9 -Site 3 (RM 103.5)during the 1984 open water season.........................................................................221 xi Figure 11.Mean daily surface and intragravel water temperatures recorded at Mainstem Susitna River at lRX 29 (RM 125.9)duri ng the 1984 open water season...........................................223 Figure 12. LIST OF FIGURES (cont.) Figure 10.Mean daily surface water temperature recorded at IYlainstem Susitna River at Curry Fishwheel Camp (RM 120.7)during the 1984 open water season ...•. Mean daily surface water temperature recorded at Mainstem Susitna River at lRX 53 (RM 140.1) during the 1984 open water season .•.............. Figure 13.Mean daily surface and intragravel water temperatures recorded at Mainstem Susitna River at lRX 56 (RM 142.1)during the 1984 open water 222 224 - ~, - - season .•.....•..•..•........e ••••••••••••••c ••••e-225 Figure 14. Figure 15. Fi gure 16. Figure 17. Figure 18. Mean daily surface water temperature recorded at Mainstem Susitna River above Portage Creek (RM 148.9)during the 1984 open water season . Mean daily surface water temperature recorded at Mainstem Susitna River above Fog Creek -Sites 1-3 (RM 176.8)during the 1984 open water season. Mean daily surface water temperature recorded at Mainstem Susitna River at Watana Dam Site (RM 184.2)during the 1984 open water season ......•.. Mean daily surface water temperature recorded at the Yentna River -Site 2 (RM 28.0,TRM 4.0) during the 1984 open water season .....•.......... Mean daily surface water temperature recorded at the Deshka River (RM 40.6,TRM 3.0)during the 1984 open water season ........••.....•.....••..•. 226 227 228 230 231 - - Figure 19.Mean daily surface water temperature recorded at the Kashwitna River (RII1 60.9,TRM 0.1)during the 1984 open water season ..•..................•..•.. xii 232 """ -~ LIST OF FIGURES (cont.) Figure 20. Figure 21. Mean daily surface water temperature recorded at the Talkeetna River -Site 3 (RM 97.2,TRM 4.0) during the 1984 open water season ......•......... Mean daily surface water temperature recorded at the Chulitna River -Site 5 (RM 98.6,TRM 11.0) during the 1984 open water season . 233 234 Figure 22. Figure 23. Mean daily'surface water temperature recorded at Portage Creek (RM 148.8,TRM 0.1)during the 1984 open water season..............................................................235 Mean daily surface water temperature recorded at Fog Creek (RM 176.7,TRM 0.1)during the 1984 open water season................................236· Figure 24. Figure 25. Mean daily surface water temperature recorded at Tsusena Creek (RM 181.8,TRM 0.1)during the 1984 open water season . Mean daily surface water temperature recorded at Deadhorse Creek (RM 120.9,TRM 1.0)duri ng the 1984 open water season ......•....••..•..•...••... 237 238 Figure 26.Mean daily intragravel water temperatures recorded at Fourth of July Creek and Plume -Site 1 (RM 131.1,TRM 0.0)during the 1984 open water season........ .. .. .......... ...... ...... .. .. .. .... ...... ...... .... .. .. .. .. .. .. .. .. .. .. .. .. ..239 Figure 27.Mean daily surface and intragravel water temperatures recorded at Indian River -Site 3 (RM 138.6,TRM 0.2)during the 1984 open water season.... .. .. ...... .. .. ...... .. .. ...... .... .... .. .. .. .. .. .. .. .. .. ...... .. .. .. .. .. ...... .. ..240 Figure 28.Mean daily surface and intragravel water temperatures recorded at Indian River -Site 4 (RM 138.6,TRM 0.2)duri ng the 1984 open water season... ... ... .... ...... ........ ..... .. .. .. ...... .. .. .. ...... ...... .. .. .. .. .. .. .. .. .. ..241 .... Figure 29.Location of the temperature monitoring station at Mainstem Susitna River at RM 18.5, GC SlGN07W15DCD..................................243 xiii ---------------- LIST OF FIGURES (cont.) Figure 30.Location of the temperature monitoring station at the Yentna River,RM 28.0,TRM 4.0, GC S18N07W28ABC..................................244 - Figure 31.Location of the temperature monitoring station at Mainstem Susitna River above the Yentna River, RM 29.5,GC S17N06W07CAD .•...•.•.....•.........•.245 GC S21N06W13AAC......................................................246 Figure 33.Location of the temperature monitoring station at Mainstem Susitna River above the Deshka River, RM 41.1,GC S19N06W26SBC •.....•.••.........•..... Figure 32.Location of the temperature monitoring station at the Deshka River,RM 40.6,TRM 3.0, 247 - Figure 37.Location of the temperature monitoring station at the Talkeetna River,RM 97.2,.TRM 4.0, GC S21N06W13AAC.................................................................251 Figure 34.Locations of the temperature monitoring stations at the Kashwitna River,RM 60.9,TRM 0.1,GC S21N06W13AAC;and Mainstem Susitna River above the Kashwitna River,RM 61.2,GC S31N05W13ABA .... Figure 35.Location of the temperature monitoring station at Mainstem Susitna River at Parks Highway Bridge, RM 83.9,GCS24N05W15BAD •.•....•...............•.. Figure 36.Location of the temperature monitoring station at Mainstem Susitna River above the Parks Highway bridge,RM 86.9,GC S26N04W16CBA .•...•.•.•.•...•• Figure 38.Location of the temperature monitoring station at the Chulitna River -Site 5,RM 98.6,TRM 11.0, GC S27N05W05ABC ............................•..... 248 249 250 252 - - Figure 39. Figure 40. Figure.'41. Locations of the temperature monitoring stations at Mainstem Susitna River at Talkeetna Fishwheel Camp,RM 103.0,GC S27N05W26DDD;and Mainstem Susitna River at LRX 9,RM 103.5,..••.•..•.•.•.• GCS27N05W25BBC. Location of the temperature monitoring station at Mainstem Susitna River at Curry Fishwheel Camp, RM 120.7,GC S27N04W10CBA ..•.••...••.••••••.•.... Location of the temperature monitoring station at Deadhorse Creek,RM 120.9,TRM 1.0,GC S29N04W14BCB .............................•0".. xiv 253 254 255 - - - LIST OF FIGURES (cont.) Figure 42.Location of the temperature monitoring station at Mainstem Susitna River at LRX 29,RM 125.9,GC S30N05W19DAB.. . . . . . . . . . . . . . . . •. . . . . . . . . . •. . . . . . . .256 Figure 43.Location of the temperature monitoring station at Fourth of July Creek -Site 1,RM 131.1,TRM 0.0, GC S30N03W03DAC..................................257 Figure 44.Location of the temperature monitoring station at Indian River -Sites 3 and 4,RM 138.6,TRM 0.2, GC S31N02W09CAB •••••,•.•••••••••.••••••.••••.••••.258 Figure 45.Location of the temperature monitoring station at LRX 53,RM 140.1,GC S31N11W10AAC ..........•.....259 Figure 46.Location of the temperature monitoring station at Mainstem Susitna River at LRX 56,RM 142.1, ~GC S31N11W36BCD..................................260 Figure 47.Locations of the temperature monitoring stations at Portage Creek,RM 148.8,TRM 0.2,GC S32N10W25ADC;and Mainstem Susitna River above Portage Creek,RM 148.9,GC S32N10W16ACB.........261 Figure 48.Locations of the temperature monitoring stations at Fog Creek,RM 176.7,TRM 0.1,GC S31N06W15DBB; and Mainstem Susitna River above Fog Creek, RM 176.8,GC S31N06W15BAC ..............•.........262 Figure 49.Location of the temperature monitoring station at Tsusena Creek,RM 181.8,TRM 0.1, GC S32N06W36ADB..................................263 -< Figure 50.Location of the temperature monitoring station at Mainstem Susitna River at Watana Dam Site, RM 184.2,GC S32N05W33BDB ..264 ARLIS Alaska Resources Library &[ufonnation ServICes Anchorage,Alaska xv 1.0 INTRODUCTION 1.1 Background The Alaska Department of Fish and Game (ADF&G)Susitna Hydro Aquatic Feasibility Study Team has collected surface and intragravel temperature data on a continuous basis at selected locations throughout the Susitna River Basin since 1981.The primary intent of the data collection program has been to characterize the seasonal surface and intragravel water temperature regimes of the mainstem Susitna River and its peripheral side channel,side slough,upland slough,tributary mouth and tributary habitats.Results of these investigations have been used by project biologists to evaluate the effects of intragravel and surface water temperatures on fish and fish habitats,and by project engineers to validate or calibrate various temperature related models. 1.'2 FY 85 Objectives The objective of the 1984 open water season temperature study conducted by the ADF&G Susitna Hydro Aquatic Feasibility Study Team was to collect sufficient surface water temperature data to meet the specific objectives of the task 32 temperature modelling study being conducted by the Arctic Environmental and Information Data Center (AEIDC). Thi s techni ca 1 memorandum presents a summary of the data co 11 ecti on methods and a summary of the initial data reduction and analyses. 1 2.0 Methods 2.1 Site Selection In support of Task 32,water temperatures were recorded at 15 mainstem Susitna River sites and 8 tributary sites located between Susitna River Miles 18.5 and 184 (Table 1 and Figure 1).Also included are additional tributary sites at which continuous water temperatures were recorded. Selection of study sites was based on discussions with AEIDC personnel (Voos and Meyer 1984). 2.2 Fie1d Data Co11ection Water temperatures were continuously recorded using either Peabody-Ryan model J-90 temperature recorders or Omnidata two channel datapod recorders.The Peabody-Ryan temperature recorders were used to record surface water temperatures only.The two channel datapod recorders were i nsta 11 ed at monitoring stations to simultaneously record i ntragravel and surface water temperatures. 2.2.1 Peabody-Ryan Temperature Recorders (Thermographs) The Peabody-Ryan model J-90 temperature recorders (thermographs) conti nuously record temperatures on a 90-day stri p chart.Instrument accuracy,as stated by the manufacturer,is ±O.6°C.Prior to field installation,each instrument was screened at two temperatures (O°C and between 10-16°C)using a calibrated American Society for Testing and Manufacturing (ASTM)thermometer as a standard.Following this 2 "'"" .. 3 - -, - and inseason stations in rnainstem open water o \0- ALAS"'"DE'ARTM[.T OF fiSH lUlilil G.....£ su HYtlftO "QU Anc STUDIES ,.- fI" 1984 o Da'(Ipod T....p.ratu'.ReCDA'd_ ~DotGpod T..,P4'(I....r./SI(l~R.cDtar o RYO:ZII T.IIl~'Q'"''RecOf'dw SUSITNA RIVER (Mainslem and Tributary) SNTEMP TEMPERATURE RECORDER SITES 1984 DPEH·WATER $£AS(J!t the .',. ~ duri ng Locations of temperature monitoring tributary habitats support of Task 32. 1.Figure 4 - ~, -. .- - ..... screening process a calibration factor was applied to each instrument. Thermographs found in error by more than 2°C at either screening temperature are returned to the manufacturer for calibration. Peabody-Ryan temperature recorders are used to monitor surface water temperatures.Thermographs are inspected twice each month to retrieve the charts and to detect malfunctioning instruments.Each time the thermographs are checked,an instantaneous water temperature measurement is taken using a cal ibrated Brooklyn thermometer (accuracy ±O.1 °e). Field installation procedures are outlined in the FY 84 ADF&G Su Hydro Aquatic Studies (May,1983 -June,1984)Procedures Manual (ADF&G 1984). 2.2.2 Omnidata Temperature Recorders (Datapods) Omnidata model DP2321 two channel temperature recorders (datapods) simultaneously record water temperatures using TP10V temperature probes. Instrument accuracy,as stated by the manufacturer,Omnidata International,is ±O.I°C.Temperature data are recorded on an ultraviolet,erasable electronic memory chip referred to as a data storage module (DSM).Temperatures are measured every five minutes and the mean,minimum,and maximum temperature measured during each six-hour ,II;interval are recorded on the DSM.Prior to installation each temperature probe is calibrated at o.ooe and assigned a correction factor.Intragravel temperatures are measured at a substrate depth of approximately 15 inches,whereas surface water temperatures are measured approximately two inches above the substrate. 5 The datapods are also examined twice each month to exchange DSM's and to 1"1'"• detect malfunctioning units.A short display sequence is activated on the datapod which enables the field investigator to determine the operating condition of the instrument and associated probes.The following information is displayed by the instrument,and recorded by the field investigator:errors made in storage,number of storage ~. points used,minutes until the next recording,and current temperatures. An instantaneous surface water temperature was also measured using a calibrated Brooklyn thermometer (accuracy ±O.1°C). Field installation procedures are outlined in the ADF&G Su Hydro Aquatic Studies (May,1983 -June 1984)Procedures Manual (ADF&G 1984). 2.3 Data Analysis 2.3.1 Peabody Ryan Temperature Recorders (Thermographs) Using field notes as a guide,all Peabody-Ryan thermograph strip charts were screened for anomalous temperatures whi ch may have resulted from instrument failure.From the strip charts,a reduced temperature data base was obtained as two-hour point temperatures. A correction value for each strip chart was determined as the difference between the temperature obtained with a calibrated Brooklyn thermometer (accuracy ±O.1°C)and the thermograph readi ng at the time the stri p chart was removed.(A correction value is determined at the time of strip chart removal rather than installation because response time of the recorder to actual water temperatures can vary with each 6 - - - ""'" - - installation).The correction value was then used to correct the two-hour point temperature data obtained from each strip chart.From these corrected data bases the daily,USGS water year weekly,and monthly minimum,mean,and maximum surface water temperatures were computer calculated and reported in tables and plots. 2.3.2 Omnidata Temperature Recorders (Datapods) Water temperature data were retrieved from the data pod temperature recorders as six-hour minimum,mean,and maximum temperatures by reading the data storage module (DSM)via an Omnidata model 217 Datapod/cassette reader into a microcomputer.These six-hour data bases were edited and corrected for storage errors and anomalous data.From these corrected data bases the daily,USGS water year weekly,and monthly mean,minimum, and maximum temperatures were computer calculated and reported in tables and plots. 3.0 RESULTS The water temperature data recorded at mainstem and tributary sites during the 1984 open water season in support of Task 32 are summarized in a series of tables and plots.Also included are site maps depicting the study locations. 7 3.1 Table 2 -Susitna River index of temperatures recorded in mainstem and tributary habitats during the 1984 open water season. 8 - - - - """'tI - r- ! Table 2.AOF&G Susitna River index of temperatures recorded in mainstem and tributary habitats during the 1984 open water season. Susitna River at Parks Hwy Bridge Thermograph RM 83.9 Surface GC S24N05W15BAD - - - Location Mainstem Sus itna Ri ver RM 18.5 GC S16N07W150CD Susitna River above the Yentna RM 29.5 GC S17N06W07CAO Susitna River above the Oeshka RM 41.1 GC S19N06W26SBC Susitna River above the Kashwitna RM 61.2 GC S31N05W13ABA Instrument! Temperature Type Thermograph Surface Surface Surface Surface Surface Surface Thermograph Surface Surface Oatapod Surface Surface Thermograph Surface Surface Surface Surface Thermograph Surface Surface Period of Record 5/24/84-6/24/84 7/8/84-7/15/84 7/19/84-8/12/84 8/19/84-8/31/84 9/12/84-9/13/84 10/17/84-10/24/84 5/24/84-7/8/84 9/1/84-10/3/84 8/14/84-8/31/84 9/12/84-9/29/84 5/24/84-5/31/84 6/1/84-6/9/84 6/29/84-7/4/84 7/24/84-11/29/84 5/24/84-7/19/84 7/25/84-10/24/84 6/8/84-6/16/84 Susitna River above Pks.Hwy Bridge Thermograph RM 86.9 Surface GC S26N04W16CBA 6/28/84-9/29/84 - - Susitna River at Talkeetna Camp RM 103.0 GC S27N05W26DOO 9 Thermograph Surface Surface 5/25/84-9/17/84 9/29/84-10/16/84 Instrument Location Temperature/Type Record Susitna River at LRX 9 Datapod RM 103.5 Intra/Surface 5/1/84-5/31/84 ~ GC S27N05W25BBC Surface 6/1/84-6/1/84 Intra/Surface 6/2/84-6/3/84 Surface 6/4/84-6/4/84 -Intra/Surface 6/5/84-6/5/84 Surface 6/6/84-6/6/84 Intra/Surface 6/7/84-6/12/84 -Surface 6/13/84-7/8/84 Intra/Surface 7/9/84-8/30/84 Surface 8/31/84-9/21/84 Intragravel 9/30/84-10/3/84 - Susitna River at Curry Camp Thermograph RM 120.7 Surface 6/4/84-10/12/84 -GC S27N04W10CBA Susitna River at LRX 29 Datapod RM 125.9,Site 3 Intra/Surface 5/25/84-5/28/84 GC S30N05W19DAB Intra/Surface 6/27/84-7/7/84 Intra/Surface 7/9/84-8/2/84 Intra/Surface 8/12/84-9/2/84 -Intra/Surface 9/12/84-10/10/84 Susitna River at LRX 53 Thermograph RM 140.1 Surface 5/23/84-10/15/84 GC S31NllW10AAC Susitna River at LRX 56 Datapod iI1"": RM 142.1 Intra/Surface 6/6/84-6/18/84 GC S31N11W36BCD Intragravel 6/19/84-7/7/84 Intra/Surface 7/8/84-7/15/84 -Intra/Surface 7/29/84-8/30/84 Intra/Surface 9/16/84-10/25/84 Susitna River above Portage Thermograph RM 148.9 Surface 5/23/84-6/24/84 GC S32N10W16ACB 6/29/84-7/25/84 7/29/84-9/28/84 Susitna River above Fog Creek Thermograph RM 176.8,Site 1 Surface 5/23/84-5/28/84 -GC S31N06W15BAC Surface 6/4/84-6/22/84 Surface 6/24/84-8/12/84 Surface 8/20/84-8/26/84 ]0 II - Instrument/-Location Temperature Type Record Talkeetna River Thermograph RM 97.2,TRM 4.0,Site 3 Surface 5/24/84-9/16/84 GC S26N04W16CBA 9/28/84-10/31/84 Chul itna River Thermograph RM 98.6,TRM 11.0,Site 5 Surface 5/23/84-10/16/84 GC S27N05W05ABC ~j Deadhorse Creek Thermograph RM 120.9,TRM 1.0 Surface 5/1/84-8/11/84 GC S29N04W14BCB Surface 9/14/84-10/31/84 ""'" Fourth of July Creek &Plume Datapod RM 131.1,Site 1 Creek Intragravel 5/1/84-5/19/84 GC S30N03W03DAC Plume &Creek-""" Intragravel 5/20/84-6/16/84 Indian River Datapod -, RM 138.6,TRM 0.2,Site 3 Intra/Surface 5/22/84-6/3/84 GC S31N02W09CAB Surface 6/4/84-6/4/84 Intra/Surface 8/11/84-10/31/84 Indian River Datapod RM 138.6,TRM 0.2,Site 4 Intra/Surface 9/28/84-10/31/84 GC S31N02W09CAB - Portage Creek Datapod RM 148.8,TRM 0.2,Site 2 Surface 5/25/84-10/15/84 GC S32N10W25ADC Fog Creek Thermograph RM 176.7,TRM 0.1 Surface 5/23/84-5/28/84 ~ GC S31N06W15DBB Surface 6/4/84-9/18/84 Surface 9/28/84-10/15/84 Tsusena Creek Thermograph RM 181.1,TRM 0.1 Surface 5/23/84-6/2/84 GC S32N06W36ADB 6/29/84-8/18/84 8/20/84-8/23/84 -8/26/84-8/28/84 8/30/84-10/15/84 ~ - - - 3.2 Tables 3 to 22 -Daily and monthly minimum,mean and maximum temperatures recorded at mainstem Susitna River sites during the 1984 open water season. /3 Appendix Table ~Ryan temperature recorder surface water temperatures Mainstem Susitna River at S16N07W15DCD. May 1984 data summary: (C)recorded at RM 18.5,GC ..... - """ - Surface Water Temperature (C) Date Min Mean Max - 840524 7.5 8.5 840525 8.0 8.1 8.5 840526 7.5 7.5 8.0 840527 7.0 7.5 8.0 840528 7.5 7.6 8.0 840529 7.5 8.1 8.5 840530 8.0 8.0 8.0 840531 7.5 8.1 8.5 Monthly Value 7.0 8.5 -----Data not available. IL-f - Appendix Table 3L continued -------------------------------_._---------------------- I June 1984 Surface Water Temperature (C) Date Min Mean Max - r - 840601 8.0 8.8 9.5 840602 9.5 10.2 11.0 840603 10.5 10.5 10.5 840604 10.0 10.6 11.0 840605 10.5 10.6 11.0 840606 9.5 10.1 10.5 840607 8.0 8.8 9.5 840608 7.5 7.8 8.0 840609 8.0 8.5 9.0 840610 9.0 9.0 9.0 840611 9.0 9.5 10.5 840612 10.5 10.9 11.5 840613 10.5 10.7 11.0 840614 9.5 9.8 10.5 840615 9.5 9.5 9.5 840616 8.5 8.9 9.5 840617 8.0 8.3 8.5 840618 8.5 8.5 8.5 840619 8.5 9.0 10.0 840620 10.5 10.7 11.0 840621 11.0 11.0 11.0 840622 10.5 11.1 11.5 840623 11.0 11.1 11.5 840624 10.0 11.0 Monthly Value 7.5 9.8 11.5 -----Data not available. IS Appendix Table S continue"d ""'" ------------------------------------------------------- July 1984 ~, ------------------------------------------------------- Surface Water Temperature (C) Date -------------------------------------Min Mean Max ------------------------------------------------------- ~840708 10.0 10.5 840709 9.5 9.8 10.5 840710 9.0 9.4 9.5 840711 8.5 9.0 9.5 840712 8.5 8.8 9.5 840713 9.5 9.5 9.5 840714 8.5 9.1 9.5 """840715 8.5 8.5 84071.9 7.0 7.3 7.5 840720 7.0 7.0 7.0 840721 7.0 7.2 7.5 ~, ! 840722 7.5 7.5 7.5 840723 8.0 8.1 8.5 840724 8.5 9.0 10.0 -840725 9.0 9.6 10.0 840726 8.5 8.7 9.0 840727 8.5 8.7 9.0 -840728 9.0 9.3 9.5 840729 8.5 8.9 9.5 840730 7.5 7.6 8.0 840731 7.5 7.5 7.5 Monthly Value 7.0 10.5 -----Data not available. - Appendix Table ]cont.inued August 1984 Surface Water Temperature (C) Date Min Mean Max -- - 840801 7.5 7.5 7.5 840802 7.5 7.5 8.0 840803 8.0 8.0 8.0 840804 8.0 8.3 9.0 840805 9.0 9.2 9.5 840806 9.5 9.5 9.5 840807 9.0 9.3 9.5 840808 9.0 9.4 9.5 840809 9.0 9.2 9.5 840810 9.0 9.0 9.0 840811 8.5 8.8"9.0 840812 9.0 9.0 840819 7.0 7.0 7.0 840820 7.0 7.0 7.0 840821 7.0 7.0 7.0 840822 7.0 7.3 7.5 840823 7.5 7.6 8.0 840824 7.5 7.5 7.5 840825 7.0 7.4 7.5 840826 7.0 7.1 7.5 840827 6.5 6.5 6.5 840828 6.0 7.0 840829 6.5 6.5 840830 6.5 6.5 6.5 840831 6.5 6.7 7.5 Monthly Value 6.0 7.8 9.5 ------------------------------------------------------- -----Data not available. 11- Appendix Table .3-continued September 1984 Surface Water Temperature (C) Date 840912 840913 Monthly Value Min 6.5 6.5 6.5 Mean Max 7.5 6.5 7.5 - -----Data not available. 18 "'"' - - Appendix Table .]continued October 1984 Surface Water Temperature (C) --Date Min Mean Max .- - - - ,- 841017 0.0 0.0 841018 0.0 0.0 0.0 841019 0.0 0.0 0.0 841020 0.0 0.0 0.0 841021 0.0 0.0 0.0 841022 0.0 0.0 0.0 841023 0.0 0.0 0.0 841024 0.0 0.0 Monthly Value 0.0 0.0 -----Data not available. 19 Append ix Tab Ie 'i Ryan temperature recorder surface water temperatures Mainstem Susitna River above RM 29.5,GC S17N06W07CAD. May 1984 data summary: (C)recorded at the Yentna River, - ~- Surface Water Temperature (C) Date Min Mean Max 840524 7.5 8.5 840525 8.0 8.1 8.5 840526 7.5 7.7 8.0 840527 7.0 7.3 8.0 840528 7.5 8.0 8.5 840529 8.0 8.3 8.5 840530 7.5 7.8 8.0 840531 7.0 8.0 9.5 Monthly Value 7.0 9.5 -----Data not available. - Appendix Table 1{continued """'------------------------------------------------------- June 1984 ------------------------------------------------------- Surface Water Temperature (C) Date ------------------------------------ Min Mean Max ------------------------------------------------------- 840601 8.5 9.6 11.0 840602 10.0 10.8 11.5 F'"840603 10.5 11.0 11.5 840604 10.0 10.9 12.0 840605 10.5 11.3 12.0 .....840606 10.0 10.4 11.5 840607 9.0 9.5 10.0 840608 9.0 9.8 10.5 840609 10.0 10.2 10.5 840610 10.0 10.4 11.0 840611 10.0 10.8 11.5 840612 10.5 11.3 12.0.....840613 11.0 11.2 12.0 840614 10.0 10.5 11.0 840615 9.5 9.8 10.5 840616 8.0 8.8 9.5 840617 7.5 8.1 9.0 840618 8.0 9.0 10.5 840619 10.0 10.8 12.0 840620 11.5 12.1 13.0 840621 12.0 12.5 13.0 840622 12.0 13 .0 14.0 840623 12.5 12.8 13.5 840624 11.0 11.6 12.5 840625 11.0 11.5 12.0 840626 11.5 11.8 12.0 840627 11.0 11.2 11.5 840628 10.0 10.4 11.0 840629 10.0 10.9 12.0 840630 11.0 12.0 13.0 Monthly Value 7.5 10.8 14.0 ------------------------------------------------------- -----Data not available. -------------------- Appendix Table 1.\continued July 1984 Surface Water Temperature (C) Date Min Mean Max -------------------------------------------------------oiIM1I!:1 840701 11.0 11.6 12.5 840702 11.0 11.3 12.0 840703 11.0 11.5 12.0 840704 10.0 10.4 11.5 840705 9.5 9.5 10.0 840706 9.5 10.8 12.0 840707 11.5 11.5 11.5 840708 10.5 10.8 11.5 Monthly Value 9.5 12.5 ~ -----Data not available. .... I Appendix Table Y continued !"'"------------------------------------------------------- September 1984 ------------------------------------------------------- F-Surface Water Temperature (C) Date ------------------------------------ Min Mean Max ------------------------------------------------------- 840901 6.5 6.8 7.5 840902 7.0 7.5 8.0 840903 7.5 7.9 8.0 840904 8.0 8.0 8.0 840905 8.0 8.2 8.5 840906 8.0 8.5 9.0 840907 9.0 9.0 9.0 840908 8.5 9.1 9.5 840909 8.5 8.8 9.0 840910 8.0 8.5 9.0 840911 8.0 8.1 8.5 840912 8.0 8.3 8.5 840913 8.0 8.1 8.5 840914 7.5 7.7 8.0 840915 7.0 7.4 7.5 840916 7.5 7.7 8.0 840917 7.5 7.8 8.0 840918 8.0 8.0 8.0 840919 7.0 7.6 8.0 840920 6.5 6.6 7.0 840921 6.0 6.4 6.5 840922 5.5 5.8 6.5 840923 5.5 5.5 5.5 840924 5.5 5.5 5.5 840925 6.0 6.0 6.0 840926 6.0 6.3 6.5 840927 6.5 6.5 6.5 840928 6.5 6.5 6.5 840929 6.5 6.5 6.5 ~840930 6.5 6.5 6.5 Monthly Value 5.5 7.4 9.5 ------------------------------------------------------- -----Data not available. Appendix Table '1 continued October 1984 - Surface Water Temperature (C) Date Min Mean Max - 841001 5.5 6.1 6.5 841002 5.0 5.1 5.5 841003 2.0 4.5 """I Monthly Value 2.0 6.5 ...., -----Data not available. :- I -- Appendix Table S-Datapod temperature recorder data summary: surface water temperatures (C)recorded at Mainstem Susitna River above the Yentna River,RM 29.5,GC S17N06W07CAD. August 1984 Surface Water Temperature (C) Date Min Mean Max 840814 11.4 12.4 840815 10.6 11.6 12.4 840816 10.9 11.8 12.7 840817 11.5 11.9 12.7 840818 10.2 10.9 12.0 840819 9.3 9.7 10.3 840820 8.0 8.5 9.5 840821 8.3 8.7 9.4 840822 9.0 9.3 9.9 840823 9.4 9.8 10.4 ~840824 9.6 10.0 10.4 840825 8.6 9.0 9.8 840826 7.5 8.1 9.0 840827 6.9 7.7 8.4 840828 6.6 7.3 8.2 840829 6.4 7.3 7.7 840830 6.4 7.3 7.7 840831 6.2 7.0 7.8 Monthly Value 6.2 12.7 ~ ------------------------------------------------------- -----Data not available •..... "'" - -----_._--~------ Appendix Table 5 continued September 1984 .- Surface Water Temperature (C) Date Min Mean Max - 840912 8.2 8.3 840913 7.7 8.3 840914 7.4 7.9 840915 6.9 7.6 840916 7.0 8.3 840917 7.8 8.8 840918 8.1 8.9 840919 7.3 8.1 840920 6.3 7.4 Monthly Value 6.3 8.9 -----Data not available. ~, - - Appendix Table b Ryan temperature recorder surface water temperatures Mainstem Susitna River above RM 41.1,GC S19N06W26SBC. May 1984 data summary: (C)recorded at the Deshka River, Surface Water Temperature (C) .... Date 840524 840525 840526 840527 840528 840529 840530 840531 Monthly Value Min 8.5 8.0 7.5 6.5 7.0 8.0 7.5 7.0 6.5 Mean 8.2 7.8 7.6 8.2 8.5 8.0 8.7 Max 9.5 8.5 8.0 8.5 9.5 9.0 8.5 10.0 10.0 - - -----Data not available. Appendix Table 6 continued June 1984 - ..". Surface Water Temperature (C) Date 840601 840602 840603 840604 840605 840606 840607 840608 840609 840629 840630 Monthly Value Min 9.0 10.0 10.0 10.0 10.5 9.5 8.5 9.0 10.0 11.5 10.5 8.5 Mean 10.2 11.0 11.0 11.1 11.4 10.3 9.5 10.1 10.4 11.4 Max 11.5 12.0 12.0 12.5 12.5 11.5 10.0 11.0 11.0 11.5 12.0 12.5 - -----Data not available. - .... Appendix Table b continued July 1984 Surface Water Temperature (C) .~ Date 840701 840702 840703 840704 840724 840725 840726 840727 840728 840729 840730 840731 Monthly Value Min 10.0 11.5 11.0 10.5 12.0 10.5 9.5 10.0 10.0 10.0 9.0 10.0 9.0 Mean 11.4 12.2 11.9 11.0 10.0 10.4 10.5 10.3 9.8 10.3 Max 13.0 13.5 12.5 11.5 13.0 11.5 11.0 11.0 11.0 11.0 10.5 10.5 13.5 - -----Data not available. Appendix Table b continued August 1984 Surface Water Temperature (C) Date 840801 840802 840803 840804 840805 840806 840807 840808 840809 840810 840811 840812 840813 840814 840815 840816 840817 . 8"40818 840819 840820 840821 840822 840823- 840824 840825 840826 840827 840828 840829 840830 840831 Monthly Value Min 10.0 9.5 9.5 10.5 12.0 11.0 11.5 11.5 11.0 10.5 10.0 10.5 10.5 10.5 10.0 10.5 11.0 10.0 9.0 8.5 8.0 8.5 9.0 9.0 8.0 7.5 7.0 6.0 6.5 6.5 6.0 6.0 Mean 10.0 9.8 10.2 11.1 12.2 11.4 12.3 12.3 11.5 11.1 10.8 11.3 11.0 11.2 11.1 11.2 11.3 10.2 9.2 8.6 8.5 8.9 9.3 9.4 8.6 7.8 7.3 6.8 7.0 7.0 6.5 9.8 Max 10.5 10.0 11.0 12.0 12.5 12.0 13.5 13.5 12.5 11.5 12.0 12.0 11.5 12.0 12.0 12.0 11.5 11.0 10.0 9.0 9.0 9.5 10.0 10.0 9.0 8.0 7.5 7.0 7.5 7.5 7.0 13.5 -----Data not available. 30 - Appendix Table "continued - - - September 1984 ------------------------------------------------------- Surface Water Temperature (C) Date ------------------------------------ Min Mean Max ------------------------------------------------------- 840901 6.0 6.7 7.5 840902 7.0 7.5 8.5 840903 7.0 7.9 8.5 840904 7.0 7.9 8.5 840905 7.0 7.9 8.5 840906 8.0 8.6 9.5 840907 8.5 8.8 9.0 840908 8.5 8.8 9.0 840909 8.0 8.5 9.0 840910 7.5 8.1 8.5 840911 7.0 7.8 8.5 840912 7.0 7.5 8.0 840913 7.0 7.3 8.0 840914 7.0 7.0 7.0 840915 6.5 6.7 7.0 840916 6.5 7.0 7.5 840917 7.0 7.5 8.0 840918 7.0 7.3 8.0 840919 7.0 7.0 7.0 840920 6.0 6.3 6.5 840921 6.0 6.2 6.5 840922 5.0 5.3 6.0 840923 5.0 5.2 5.5 840924 5.0 6.0 840925 5.5 5.8 6.0 840926 6.0 6.3 7.0 840927 5.5 5.9 6.5 840928 5.0 5.3 6.0 840929 5.0 5.0 5.0 840930 5.0 5.3 5.5 Monthly Value 5.0 6.9 9.5 -----Data not available. 3·/ ~~--~----_.~._---~----------------- Appendix Table 6 continued October 1984 - - Surface Water Temperature (C) Date 841001 841002 841003 841004 841005 841006 841007 841008 841009 841010 841011 841012 841013 841014 841015' 841016 841017 841018 841019 841020 841021 841022 841023 841024 841025 841026 841027 841028 841029 841030 841031 Monthly Value Min 5.5 5.0 5.0 4.0 3.0 2.5 3.0 3.0 3.0 2.5 2.5 1.5 1.5 1.5 .5 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Mean 5.5 5.2 5.0 4.1 3.0 2.8 3.0 3.0 3.0 2.7 2.6 1.7 1.7 1.5 .6 .0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1.5 Max 5.5 5.5 5.0 4.5 3.5 3.0 3.0 3.0 3.0 3.0 3.0 2.5 2.0 2.0 1.5 .5 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 5.5 - -----Data not available. Appendix Table G continued November 1984 SHrface Water Temperature (C) - Date 841101 841102 841103 841104 841105 841106 841107 841108 841109 841110 841111 841112 841113 841114 841115 841116 841117 841118 841119 841120 841121 841122 841123 841124 841125 841126 841127 841128 841129 Monthly Value Min 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Mean 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 '0.0 0.0 0.0 0.0 Max 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 -----Data not available. 33 Appendix Table Ryan temperature recorder surface water temperatures Mainstem Susitna River above RM 61.2,GC S31N05W13ABA. data summary: (C)recorded at Kashwitna River, May 1984 Surface Water Temperature (C)'-Date Min Mean Max 840524 8.5 9.5 840525 7.0 7.8 8.5 840526 7.0 7.5'8.0 840527 6.5 7.6 8.5 840528 7.0 8.2 9.5 840529 8.0 8.3 8.5 840530 8.0 8.1 8.5 840531 7.5 8.5 10.0 Monthly Value 6.5 10.0 - - - -----Data not available.• - ,.,.., Appendix Table t continued ------------------------------------------------------- f'-June 1984 ------------------------------------------------------- Surface Water Temperature (C) Date ------------------------------------ Min Mean Max ------------------------------------------------------- 840601 8.5 10.0 11.5 840602 9.5 10.7 12.0 840603 10.0 10.7 11.5 840604 10.0 10.7 12.0 840605 10.0 11.0 12.0 840606 9.5 10.1 11.0 840607 8.0 9.2 10.0 ~840608 9.0 10.1 11.0, 840609 10.0 10.4 11.0 840610 9.5 10.3 11.0 840611 10.5 11.0 11.5 840612 11.0 11.5 12.5 840613 10.5 11.0 11.5 840614 9.0 10.0 11.0 840615 9.5 10.0 10.5 840616 8.0 8.5 9.0 840617 7.5 8.3 9.0 840618 8.5 9.8 11.5 840619 10.5 11.6 13.0 840620 12.0 12.6 13.5 ......840621 12.0 12.7 13.5 840622 12.5 13.3 14.0 840623 12.0 12.8 13.5 840624 11.0 11.8 12.5-840625 11.5 12.0 12.5 840626 12.0 12.1 12.5 840627 11.0 11.2 12.0 "...840628 10.0 10.6 11.0 840629 11.0 11.5 12.5 840630 11.0 11.8 12.5 .... Monthly Value 7.5 10.9 14.0 -------------------------------------------------------- -----Data not available. AppeI?-dix Table '+continued -" -------------------------------------------------------"""'! July 1984 ------------------------------------------------------- Surface Water Temperature (C) Date ------------------------------------~ Min Mean Max ------------------------------------------------------- """840701 12.0 12.0 12.0 840702 11.0 11.4 12.0 840703 10.0 10.9 12.0 840704 11.0 12.2 13.5 840705 12.5 12.8 13.5 840706 12.0 12.3 12.5 840707 11.0 12.1 13.0 .... 840708 11.5 12.0 12.5 840709 11.0 11.3 11.5 840710 11.0 11.2 12.0 ~ 840711 10.0 10.9 11.5 840712 11.0 11.5 12.0 840713 11.0 11.2 11.5 840714 10.5 11.1 11.5 - 840715 11.0 11.6 12.5 840716 12.0 12.0 12.0 840717 10.0 10.8 11.5 840718 9.5 9.9 10.0 840719 9.0 9.0 840725 10.5 11.0 840726 10.0 10.4 11.0 840727 10.0 10.5 11.0 840728 10.0 10.7 11.5 840729 10.0 10.2 11.0 ~ 840730 9.5 -10.4 11.0 840731 10.5 10.5 10.5 ~. M.onthly Value 9.0 11.2 '13.5 -----Data not available. - - Appendix Table 1 continued August 1984 Surface Water Temperature (C) Date Min Mean Max """840801 10.0 10.0 10.0 840802 10.0 10.1 10.5 840803 10.0 10.5 11.0 840804 10.5 11.1 12.0 840805 11.5 11.8 12.0 840806 10.5 11.3 12.0 840807 12.0 12.4 13.0 840808 11.5 12.0 12.5 840809 10.5 11.4 12.0 840810 10.5 10.8 12.0 840811 10.0 10.9 12.0 840812 10.0 10.7 11.5 840813 10.0 10.4 11.0 840814 10.0 10.5 11.0 840815 10.0 10.4 11.0 840816 10.0 10.8 11.5 840817 10 ..0 10.6 11.0 840818 9.5 9.7 10.0 840819 9.0 9.0 9.5 840820 8.5 8.6 9.0 840821 8.5 8.7 9.0 840822 8.5 8.8 9.0 840823 8.5 9.1 10.0 840824 8.5 8.8 9.0 840825 8.0 8.5 8.5 840826 7.5 7.7 8.0 840827 6.5 6.8 7.0 840828 5.5.6.3 6.5 840829 5.5 6.4 7.0 840830 6.0 6.5 7.0 840831 5.5 5.9 6.0 Monthly Value 5.5 9.6 13.0 ------------------------------------------------------- -----Data not available. Appendix Table 7 continued September 1984 - - Surface Water Temperature (C) Date Min 38 Mean Max -- Appendix Tab 1e '7 Date continued October 1984 Surface Water Temperature (C) Min Mean Max - - 841001 6.0 6.4 6.5 841002 6.5 6.7 7.0 841003 6.0 6.3 6.5 841004 4.5 4.9 5.5 841005 3.5 3.9 4.0 841006 3.5 4.1 4.5 841007 4.0 4.3 4.5 841008 4.0 4.0 4.0 841009 4.0 4.0 4.0 841010 3.5 3.9 4.0 841011 2.5 2.6 -3.0 841012 2.0 2.6 3.0 841013 2.5 2.7 3.0 841014 1.5 2.3 2.5 841015 1.0 1.1 1.5 841016 0.0 .5 1.0 841017 0.0 0.0 0.0 .841018 0.0 0.0 0.0 841019 0.0 0.0 0.0 841020 0.0 0.0 0.0 841021 0.0 0.0 0.0 841022 0.0 0.0 0.0 841023 .5 .5 .5 841024 0.0 .5 Monthly Value 0.0 2.6 7.0 -----Data not available. Appendix Table B Ryan temperature recorder data·summary~ surface water temperatures (C)recorded at Mainstem Susitna River at Parks Highway Bridge Center Span -Site 4,RM 83.9GC S24N05W15BAD. June 1984 """ Surface Water Temperature (C). Date Min Mean Max 840608 8.0 10.0 840609 9.0 9.2 10.0 840610 8.0 9.3 10.5 840611 9.0 10.1 11.0 840612 10.0 10.5 11.0 840613 9.0 9.6 10.5 840614 7.5 8.5 9.5 840615 8.0 8.7 9.5 840616 7.0 7.3 8.0 Monthly Value 7.0 11.0 -----Data not available. 4-0 """ - - "~ Appendix Table 1 Ryan temperature recorder data summary: surface water temperatures (C)recorded at Mainstem Susitna River above the Parks Highway Bridge,RM 86.9,GC S24NOsWOIBCD. June 1984 Surface Water Temperature (C) Date 840628 840629 840630 Monthly Value Min 8.5 8.5 8.5 8.5 Mean 9.2 9.4 Max 9.0 9.5 10.0 10.0 - -----Data not available. 41 Appendix Tab Ie ~continued - ------------------------------------------------------- July 1984 ------------------------------------------------------- Surface Water Temperature (C).~ Date ------------------------------------ Min Mean Max -------------------------------------------------------- 840701 9.0 9.7 10.0 840702 8.0 8.6 10.0 840703 7.5 8.3 9.0 -840704 9.0 9.7 10.5 840705 9.0 9.6 10.5 840706 8.5 9.2 9.5 -840707 7.5 8.8 10.0 840708 8.0 9.0 9.5 840709 8.0 8.5 9.0 840710 8.5 8.7 9.0 840711 8.0 8~5 9.5 840712 8.5 9.1 9.5 840713 8.5 8.9 9.5 -840714 8.5 9.0 9.5 840715 9.0 9.7 10.5 840716 9.5 9.9 10.5 ---i8407178.0 8.4 9.5 840718 7.5 7.9 8.0 840719 7.5 7.5 7.5 840720 7.0 7.3 7.5 840721 7.5 7.7 8.0 840722 7.5 7.8 8.0 840723 8.0 8.9 10.5 840724 9.0 9.7 10.5 840725 8.0 8.3 9.0 840726 7.0 7.8 8.5 840727 8.5 9.0 9.5 840728 9.0 9.1 9.5 840729 8.5 8.6 9.0 840730 8.0 8.6 9.5 840731 9.0 9.0 9.0 Monthly Value 7.0 8.7 10.5 ------------------------------------------------------- -----Data not available.- Appendix Table 9 continued ;~------------------------------------------------------- August 1984 ------------------------------------------------------- Surface Water Temperature (C) Date ------------------------------------ Min Mean Max ------------------------------------------------------- 840801 8.5 8.6 9.0 840802 8.5 8.5 8.5 840803 8.5 9.0 9.5 840804 9.0 9.9 10.5 840805 8.5 9.8 10.5 840806 8.0 9.2 10.5 840807 9.0 9.7 10.0 840808 8.5 9.1 10.0 840809 7.5 8.7 9.5 840810 8.0 8.5 9.0 840811 8.5 9.3 10.0 840812 8.5 9.1 9.5 840813 8.0 9.0 9.5 840814 8.0 8.9 9.5 840815 8.0 8.9 9.5 840816 8.5 8.9 9.5 840817 8.0 8.7 9.5 840818 7.0 7.2 8.0 840819 6.5 6.8 7.0 840820 6.5 6.6 7.0 840821 7.0 7.0 7.0 840822 7.0 7.2 7.5 840823 7.5 7.7 8.0 840824 7.0 7.5 8.5 840825 7.0 7.0 7.0 840826 6.5 7.0 7.5,-840827 6.0 6.6 7.0 840828 5.5 6.0 6.5 840829 5.0 5.5 6.0 840830 4.5 5.2 5.5 840831 5.0 5.1 5.5 Monthly Value 4.5 7.9 10.5 ------------------------------------------------------- -----Data not available. '-/3 Appendix Table ~continued September 1984 Surface Water Temperature (C) Date 840901 840902 840903 840904 840905 840906 840907 840908 840909 840910 840911 840912 840913 840914 840915 840916 840917 840918 840919 840920 840921 840922 840923 840924 840925 840926 840927 840928 840929 Monthly Value Min 5.0 6.0 6.0 6.5 6.5 7.0 7.0 7.0 6.5 6.0 6.0 6.0 6.0 5.5 5.5 6.5 6.5 6.5 5.5 5.0 4.5 4.5 4.5 4.5 5.0 5.5 5.5 5.0 5.0 4.5 Mean 5.5 6.4 6.6 6.8 7.0 7.3 7.5 7.3 7.0 6.3 6.3 6.2 6.2 5.6 6.0 6.7 6.8 6.5 5.8 5.3 5.0 4.7 4.5 4.7 5.2 5.6 5.6 5.2 6.0 Max 6.5 7.0 7.0 7.0 7.5 7.5 8.0 7.5 7.5 7.0 6.5 6.5 6.5 6.0 6.5 7.0 7.0 6.5 6.5 5.5 5.5 5.0 4.5 5.0 5.5 6.0 6.0 5.5 5.0 8.0 - -----Data not available. ~. ..... Appendix Table 10 Date Ryan temperature recorder data summary: surface water temperatures (C)recorded at Mainstem Susitna River at Talkeetna Fishwheel Camp,RM 103.0,GC S27N05W26DDD. May 1984 Surface Water Temperature (C) Min Mean Max "''''1',I •I I 840525 6.0 6.5 840526 5.5 5.8 6.0 840527 5.5 6.2 7.0 840528 5.5 6.8 8.0 840529 6.5 7.1 8.0 840530 6.5 7.2 8.0 840531 7.0 8.1 9.5 M.onthly Value 5.5 9.5 -----Data not available. 45 Appendix Table 10 .continued June 1984 - Surface Water Temperature (C) Date Min Mean Max '"'" 840601 7.5 8.8 10.0 840602 8.0 9.2 10.5 840603 8.5 9.5 10.5 840604 9.0 10.0 11.0 840605 9.0 9.8 10.5 840606 8.5 8.8 9.5 840607 8.0 9.0 9.5 840608 8.5 9.3 10.5 840609 9.0 9.4 10.0 840610 9.0 9.8 10.5 840611 9.5 10.2 11.0 . 840612 10.0 10.5 11.0 840613 9.5 9.9 10.0 840614 8.0 8.9 9.5 840615 8.0 8.7 9.0 840616 7.0 7.5 8.0 840617 6.5 7.1 8.0 840618 7.5 8.8 10.0 840619 10.0 11.0 12.0 840620 12.0 12.2 12.5 840621 11.5 12 .5 13.5 840622 12.0 12.8 13.5 840623 12.5 12.5 13.0 840624 11.5 12.0 12.5 840625 11.5 12.2 13.0 840626 12.0 12.2 12.5 840627 10.0 11.2 12.0 840628 9.5 10.4 11.0 840629 10.5 11.1 11.5 840630 11.0 12.1 13.0 Monthly Value 6.5 10.3 13.5 ------------------------------------------------------- -----Data not available. - --. Appendix Table \0 continued July 1984 Surface Water Temperature (C) Date . Min Mean Max -- - 840701 12.0 12.4 13.0 840702 11.5 11.9 12.0 840703 11.5 12.1 12.5 840704 11.5 12.7 13.5 840705 12.5 12.9 13.5 840706 12.0 12.9 13.5 840707 12.0 12.8 13.5 840708 11.5 12.0 12.5 840709 11.0 11.8 12.0 840710 11.0 11.4 12.0 840711 11.0 11.9 12.5 840712 11.5 12.0 12.5 840713 11.5 12.1 12.5 840714 11.5 12.1 13.0 .. 840715 11.5 12.4 13.0 840716 12.0 12.3 13.0 840717 10.5 11.3 12.0 840718 9.0 9.8 10.0 840719 9.0 9.3 9.5 840720 9.0 9.2 9.5 840721 9.0 9.2 9.5 840722 9.0 9.6 10.0 840723 9.5 11.1 12.0 840724 11.5 11.8 12.0 840725 11.0 11.6 12.0 -840726 10.0 10.7 11.0 840727 10.0 10.1 10.5 840728 10.0 11.0 840729 10.5 10.9 11.0 840730 10.5 11.0 11.5 840731 10.5 10.7 11.0 Monthly Value 9.0 11.4 13.5 ------------------------------------------------------- -----Data not available. Appendix Table 10 continued ...., ~------------------------------------------------------- August 1984 ------------------------------------------------------- Surface Water Temperature (C) Date ------------------------------------ Min Mean Max -------------------------------------------------------~ 840801 10.0 10.3 10.5 840802 10.5 10.7 11.0 840803 10.5 11.1 11.5 840804 11.0 12.3 14.0 840805 13.0 13.0 13.0 840806 12.5 13.5 14.5 ~ 840807 13.0 13.5 14.0 840808 12.5 12.9 13.0 840809 12.0 12.5 13.0 """840810 11.0 11.6 12.0 840811 11.0 11.6 12.0 840812 10.5 11.3 12.0 840813 10.5 11.2 12.0 ~ 840814 10.0 11.0 12.0 840815 10.0 11.2 12.5 840816 11.0 12.0 13 .0 ,.119, 840817 11.5 12.0 12.5 840818 11.5 11.5 12.0 840819 10.5 11.0 11.5 840820 10.0 10.0 10.5 840821 9.5 9.9 10.0 840822 9.0 9.2 9.5 840823 9.0 9.2 9.5 840824 8.5 8.8 9.5 840825 .7.5 7.9 8.5 840826 6.0 6.7 7.0 840827 5.0 5.5 6.0 840828 5.0 5.5 6.0 840829 5.0 5.7 6.5 840830 5.0 5.7 6.5 840831 5.0 5.8 6.5 Monthly Value 5.5 10.3 14.5 ~ ------------------------------------------------------- -----Data not available. Appendix Table \0 continued September 1984 Surface Water Temperature (C) Date Min Mean Max 840901 5.5 6.4 7.5 840902 5.5 6.8 8.0 840903 6.0 7.2 8.0 840904 6.5 7.4 8.0 840905 7.0 7.9 8.5 840906 7.5 8.3 9.0 840907 8.0 8.5 9.0 840908 7.5 8.3 9.0 840909 7.0 7.5-8.0 840910 6.5 7.3 8.0 840911 6.5 7.1 7.5 840912 6.5 7.0 7.5 840913 7.0 7.2 7.5 840914 6.5 6.7 7.0 840915 6.5 7.0 7.5 840916 6.5 7.4 8.0 840917 7.0 8.0 840929 6.0 6.0 840930 5.5 5.8 6.0 Monthly Value 5.5 9.0 -----Data not available. 4-'1 ) Appendix Table \0 continued October 1984 - Surface Water Temperature (C) Date Min Mean Max 841001 5.5 5.8 6.0 841002 5.5 5.8 6.0 841003 5.0 5.3 6.0 841004 3.5 3.8 4.5 -841005 2.5 2.9 3.0 841006 3.0 3.2 3.5 841007 2.5 2.8 3.0 ~ 841008 2.5 2.8 3.0 841009 3.0 3.2 3.5 841010 2.5-2.7 3.0 841011 1.0 1.5 2.0 841012 1.5 1.7 2.0 841013 1.5 1.7 2.0 841014 1.0 1.1 1.5 1lO"! 841015 0.0 .1 .5 841016 0.0 0.0 -Monthly Value 0.0 -----6.0 -------------------------------------------------------------Data not available. ~, Appendix Table I \ Datapod temperature recorder data summary: intragrave1 and surface water temperatures (C)recorded at Mainstem Susitna River at LRX.9 -Site 3,RM 103.5,GC 27N05W26ADD. ----------------------------------------------------------------- May 1984 ----------------------------------------------------------------- Intragrave1 Surface water Date -------------------------------------- Min Mean Max Min Mean Max ----------------------------------------------------------------- 840501 .1 .2 .3 -.1 .1 .5 840502 -.2 .0 .2 -.1 -.1 .2 840503 -.1 .7 2.3 -.1 -.1 0.0 840504 1.9 1.9 2.0 -.1 -.1 -.1 840505 2.1 2.2 -.1 -.1 0.0 840506 2.0 2.2 2.4 -.2 -.1 -.1 840507 2.1 2.2 3.4 -.1 -.1 -.1 840508 1.6 1.7 2.1 -.2 -.1 .2 840509 2.0 3.4 -.1 1.7 2.4 840510 3.3 3.4 3.5 .2 2.1 2.7 840511 3.3 3.4 3.5 0.0 .7 2.8 840512 3.3 3.4 3.5 0.0 .3 .8 840513 3.4 3.5 3.6 .1 2.2 5.5 840514 3.6 3.6 3.8 1.3 3.5 6.4 840515 3.6 3.7 3.9 1.3 3.4 5.7 840516 3.7 3.8 3.9 1.3 2.7 4.6 840517 3.6 3.8 4.0 .1 2.5 4.6 840518 3.7 3.9 4.0 1.4 3.0 4.1 840519 3.7 3.8 4.1 2.3 3.0 3.8 _. 840520 3.6 3.8 4.0 1.9 3.1 4.5 840521 4.0 4.2 4.7 3.8 5.0 6.3 840522 4.4 4.5 4.6 4.9 5.4 5.9 840523 4.4 4.6 4.3 5.4 6.6 840524 4.6 4.7 4.7 5.5 6.1 6.7 840525 4.6 4.7 4.9 5.4 6.0 6.9 840526 4.7 4.8 4.9 5.4 5.9 6.4 840527 4.5 4.6 4.7 5.4 6.2 7.2 840528 4.3 4.4 4.6 5.5 6.8 8.4 840529 4.2 4.3 4.5 5.9 7.1 8.6 840530 4.1 4.1 4.3 6.2 7.2 8.3 840531 4.0 4.1 4.2 6.1 8.2 11.0 Monthly Value -.2 3.4 4.9 -.2 3.1 11.0 ----------------------------------------------------------------- ----Data not available. 5/ Appendix Table 1\continued - ----------------------------------------------------------------- June 1984 ~, ----------------------------------------------------------------- Intragravel Surface water Date -------------------------------------- Min Mean Max Min Mean Max ----------------------------------------------------------------- 840601 6.5 9.0 11.7 840602 4.2 4.4 7.1 9.2 11.7 840603 4.3 4.4 7.9 9.5 11.0 840604 8.1 10.1 11.4 [IIl(4iIi 840605 5.4 5.6 8.2 10.0 11.3 840606 8.7 9.2 10.6 840607 5.3 5.5 8.1 9.1 10.2 840608 5.4 6.2 7.6 8.3 9.4 10.5 840609 5.5 5.6 5.7 9.1 9.6 10.4 840610 5.5 5.7 5.9 9.0 9.9 11.2 840611 5.7 5.8 8.3 9.3 10.5 11.7 840612 5.8 8.2 10.3 10.9 11.9 840613 9.5 10.0 11.1 840614 8.0 8.9 9.7 840615 8.4 8.9 9.5 840616 7.1 7.7 8.4 840617 6.5 7.0 8.1 840618 8.0 8.9 10.4 ~ 840619 10.3 11.1 12.3 840620 12.1 12.4 12.8 840621 11.7 12.6 13.5 840622 12.4 13.2 13 .9 840623 12.2 12.8 13 .7 840624 11.5 12.2 12.8 -840625 11.5 12.4 13.6 840626 12.1 12.6 13.2 840627 11.3 11.7 12.3 840628 9.8 10.5 11.3 ~, 840629 10.7 11.3 12.0 840630 11.1 11.9 13.2 Monthly Value 4.2 8.3 6.5 10.4 13.9 ----------------------------------------------------------------- -----Data not available. Appendix Table 'I continued ----------------------------------------------------------------- July 1984 ----------------------------------------------------------------- Intragrave1 Surface water Date -------------------------------------- Min Mean Max Min Mean Max ----------------------------------------------------------------- 840701 11.5 12.3 13 .0 840702 11.4 11.7 12.4 840703 11.0 11.5 12.4."'"840704 11.1 12.2 13 .5 840705 11.9 12.8 13.5 840706 12.0 12.9 13.8 840707 11.9 12.9 14.0 840708 11.7 12.3 13.1 840709 8.3 8.5 11.8 12.4 12.9 840710 7.6 7.9 8.3 11.5 12.1 13 .0 840711 7.8 8.1 8.6 11.8 12.5 13.6 840712 8.1 8.4 8.6 12.1 13.0 14.0 840713 8.0 8.2 8.5 12.7 13.0 13 .5 ![840714 8.0 8.3 8.6 12.6 13.4 14.4, 840715 7.9 8.3 8.7 12.5 13.5 15.0 840716 7.9 8.2 8.6 13.1 13.9 14.6 840717 7.9 8.0 8.3 12.3 12.9 13.8 840718 7.4 7.6 8.0 10.8 11.3 12.3 840719 7.0 7.2 7.4 10.4 11.1 11.5 840720 6.8 7.0 7.1 10.8 11.3 11.5 840721 6.8 7.1 7.2 10.7 11.3 11.6 840722 7.0 7.3 7.6 10.8 11.4 12.2 840723 7.5 7.8 8.5 11.5 12.3 14.0 840724 8.4 8.6 8.8 13.2 13.6 14.1 840725 8.4 8.6 8.8 12.8 13.4 13.9 840726 8.2 8.9 9.2 11.1 12.1 12.9 !""'1'840727 8.4 8.9 9.2 10.0 11.0 11.7 840728 8.4 9.0 9.2 10.3 11.5 12.1 840729 7.8 8.8 9.2 10.3 11.4 12.0 840730 7.4 8.6 9.2 9.6 11.3 12.3 840731 7.7 8.8 9.2 9.8 11.2 12.1 Monthly Value 6.8 8.2 9.2 9.6 12.2 15.0 ----------------------------------------------------------------- -----Data not available. 53 Appendix Table l\continued - ----------------------------------------------------------------- 1984 ~August ----------------------------------------------------------------- Intragravel Surface water Date --------------------------------------~. Min Mean Max Min Mean Max ------------------------------------------------------------------840801 7.0 8.1 8.7 9.1 10.5 11.5 840802 7.0 8.2 8.8 9.3 10.7 11.6 840803 7.0 8.4 9.1 10.5 12.3 13.7 840804 7.3 8.8 10.0 10.9 13.3 15.5 840805 8.2 9.3 10.0 12.2 13.9 15.3 840806 8.1 9.8 1l.1 12.1 14.3 16.5 840807 8.2 10.2 1l.1 11.6 14.2 15.8 ~ 840808 8.2 9.8 10.8 11.5 13.5 14.8 840809 7.3 9.4 10.6 10.3 12.8 14.7 840810 5.7 8.2 9.4 7.8 10.8 12.4 840811 6.6 8.5 9.6 8.8 11.2 12.9 _. 840812 4.7 7.6 9.7 6.7 10.2-13.0 840828 6.7 7.0 6.5 6.8 840829 3.6 6.0 8.1 3.0 5.4 7.2 840830 4.1 6.1 8.7 4.8 6.2 7.4 840831 4.1 5.9 7.4 Monthly Value 3.6 11.1 3.0 16.5 ------------------------------------------------------------------ -----Data not available. ..." Appendix Table II continued September 1984 Intragrave1 Surface water Date Min Mean Max Min Mean Max 840901 4.5 7.0 9.6 840902 5.6 7.3 840912 6.0 8.0 840913 6.9 7.8 8.0 840914 5.5 6.9 7.5 840915 4.6 6.9 8.2...'840916 4.2 7.1 9.0I : 840917 5.6 7.7 8.6 840918 5.3 7.0 7.8 840919 4.5 6.3 7.5 840920 2.6 5.2 7.4 840921 2.2 5.4 840930 2.3 4.0 6.8 Monthly Value 2.3 6.8 2.2 9.6 -----Data not available. -55 Appendix Table 1\continued October 1984 Intragravel Surface water Date Min Mean Max Min Mean Max -841001 1.3 3.2 5.5 841002 1.8 3.2 6.2 841003 .4 2.0 5.3 ~ Monthly Value .4 6.2 - -----Data not available. - 5{o - Appendix Table \~Ryan temperature recorder data summary: surface water temperatures (C)recorded at Mainstem Susitna River at Curry Fishwheel Camp,RM 120.7,G~S27N04WI0CBA. """------------------------------------------------------- June 1984 ------------------------------------------------------- Surface Water Temperature (C) Date ------------------------------------ Min Mean Max -------------------------------------------------------...., 840604 9.5 10.0 840605 8.5 9.2 9.5 840606 8.5 8.8 9.0 840607 8.0 8.5 9.0 840608 8.0 8.8 9.5 840609 9.0 9.1 9.5 840610 9.0 9.4 10.0 840611 9.0 9.6 10.0 840612 9.5 9.9 10.0 F""840613 9.0 9.2 9.5, 840614 7.5 8.4 9.0 840615 8.0 8.3 9.0 840616 6.0 6.9'7.5 840617 6.0 6.5 7.5 840618 7.5 8.5 10.0 840619 10.0 10.5 11.5 840620 11.0 11.5 12.0 840621 11.0 11.7 12.5 840622 12.0 12.3 13.0 840623 11.5 12.0 13.0 840624 11.0 11.4 11.5 840625 11.0 11.7 12.0 840626 11.5 12.0 12.0 840627 10.0 11.0 11.5 840628 9.5 9.9 10.5 840629 10.5 10.7 11.0 840630 11.0 11.4 12.0 Monthly Value 6.0 9.9 13.0 -----Data not available. """57 Appendix Table I~continued ------------------------------------------------------- July 1984 - -------~----------------------------------------------- Surface Water Temperature (C) Date -------------------------------------, Min Mean Max ------------------------------------------------------- 840701 11.5 11.9 12.0 - 840702 11.5 11.6 12.0 840703 11.0 11.5 12.0 840704 11.5 12.0 12.5 840705 12.0 12.3 12.5 840706 12.5 12.5 12.5 840707 12.0 12.1 12.5 ~ 840708 11.5 12.0 12.0 840709 11.5 11.5 11.5 840710 11.0 11.0 11.5 840711 11.0 11.5 12.0 """'. 840712 11.5 11.7 12.0 840713 11.5 11.8 12.0 840714 11.5 11.8 12.0 ..., 840715 11.0 11.7 12.0 840716 12.0 12.0 12.0 840717 10.5 11.3 12.0 840718 9.5 9.6 10.0 ~, 840719 9.0 9.0 9.0 840720 9.0 9.0 9.0 840721 9.0 9.0 9.0 840722 9.0 9.3 9.5 840723 9.5 10.3 11.0 840724 11.0 11.4 11.5 -840725 11.0 11.4 11.5 840726 10.0 10.6 11.0 840727 9.5 9.8 10.0 840728 10.0 10.5 10.5 840729 10.5 10.5 10.5 840730 10.0 10.3 11.0 840731 10.0 10.0 10.5 ~ Monthly Value 9.0 11.0 12.5 j!IQJ------------------------------------------------------- --~--Data not available. Appendix Table I~continued Appendix Table I~continued September 1984 ------------------------------------------------------- Surface Water Temperature (C) Date ------------------------------------ Min Mean Max ------------------------------------------------------- 840901 5.0 5.6 6.0 840902 5.5 6.4 7.0 840903 6.0 6.5 7.0 840904 6.0 6.8 7.0 840905 7.0 7.3 7.5 840906 7.5 7.8 8.0 840907 7.5 7.7 8.0 840908 6.5 7.3 8.0 849909 6.5 6.9 7.5 840910 6.0 6.8 7.5 840911 6.0 6.7 7.5 840912 6.0 6.5 7.0 840913 6.5 7.0 7.0 840914 •6.0 6.4 6.5 840915 6.0 6.6 7.0 840916 6.5 7.0 7.5 840917 6.0 6.5 7.0 840918 6.5 6.5 6.5 840919 6.0 6.4 6.5 840920 5.5 5.8 6.0 840921 5.0 5.2 5.5 840922 4.0 4.3 4.5 840923 4.0 4.2 4.5 840924 4.5 4.5 4.5 840925 4.5 4.7 5.0 840926 5.0 5.0 5.0 840927 4.5 4.8 5.0 840928 4.0 4.3 4.5 840929 4.5 4.8 5.5 840930 5.0 5.3 5.5 Monthly Value 4.0 6.0 8.0 -----Data not available. (PO ~, - ~. Appendix Table l~continued October 1984 Surface Water Temperature (C) Date Min Mean Max ,.,.. 841001 5.0 5.4 5.5 841002 5.0 5.3 5.5 841003 4.5 4.7 5.0 841004 3.0 3.4 4.0 841005 2.5 2.5 2.5 841006 2.5 2.5 2.5 841007 2.5 2.5 2.5 841008 2.5 2.5 2.5 841009 2.5 2.7 3.0 841010 2.5 2.5 3.0 841011 1.0 1.5 2.0 841012 1.5 1.5 Monthly Value 1.0 5.5 -----Data not available. Appendix Table 13 Datapod temperature recorder data summary: intragravel and surface water temperatures (C)recorded at Mainstem Susitna River at LRX 29 -Site 3,RM 125.9,GC S30N05W19DAB. May 1984 - Surface water Date Intragravel Min Mean Max Min Mean Max 840525 5.6 5.8 6.0 6.6 840526 5.4 5.6 5.7 5.3 5.7 6.2 840527 5.4 5.6 5.8 5.4 6.0 6.6 840528 5.8 5.9 6.2 6.6 Monthly Value 5.4 5.9 5.3 6.6 -----Data not available.- - - ..", - - Appendix Table l~ Date continued June 1984 Intragravel Surface water Min Mean Max Min Mean Max 840627 11.5 11.8 10.6 11.2 840628 10.6 10.9 11.5 9.6 10.2 11.0 840629 10.7 10.9 11.1 10.8 11.1 11.6 840630 8.7 11.4 11.9 11.4 11.9 12.9 Monthly Value 8.7 11.9 9.6 12.9 -----Data not available. 03 Appendix Table \3 continued - ----------------------------------------------------------------- July 1984 ----------------------------------------------------------------- Intragrave1 Surface water Date ------------------- --------------------Min Mean Max Min Mean Max ----------------------------------------------------------------- lMW'! 840701 11.8 12.0 12.2 12.0 12.5 13.0 840702 10.1 11.9 12.2 11.8 12.0 12.4 840703 10.5 11.7 12.0 11.4 11.9 12.6 -840704 11.3 12.0 12.4 11.7 12.4 13.3 840705 12.4 12.6 12.9 12.5 12.9 13.3 840706 9.6 12.6 12.8 12.8 13.0 13.5 840707 10.5 12.6 12.9 12.2 12.7 13.2 .~ 840709 11.2 11.4 11.6 12.0 840710 11.0 11.1 11.4 11.2 11.5 11.9 840711 11.0 11.2 11.6 11.4 11.8 12.9 ~ 840712 11.2 11.4 11.7 11.6 12.0 12.8 840713 11.4 11.6 12.0 11.9 12.3 12.9 840714 11.5 11.7 11.9 12.0 12.3 12.9 840715 11.3 11.6 11.8 11.7 12.2 12.9 - 840716 11.5 11.8 11.9 12.2 12.5 13.0 840717 11.1 11.6 11.9 11.1 11.9 12.4 840718 10.0 10.5 11.1 9.9 10.3 11.1 ~~ 840719 9.3 9.6 10.0 9.3 9.6 9.9 840720 9.5 9.8 10.1 9.4 9.6 9.8 840721 9.4 9.6 10.0 9.3 9.4 9.7 840722 9.3 9.7 10.2 9.4 9.7 ~10.3 840723 9.4 9.6 10.2 10.0 10.7 12.1 840724 10.2 10.7 11.0 11.9 12.1 12.4 840725 10.9 11.3 11.7 12.1 12.4 12.6 840726 10.6 11.2 11.6 10.9 11.4 12.1 840727 9.8 10.1 10.7 10.0 10.5 n.O 840728 9.9 10.6 11.4 10.7 11.2 11.4 ~840729 10.5 11.0 11.8 11.3 11.7 11.9 840730 10.4 11.2 11.9 10.9 11.4 12.0 840731 10.5 10.6 10.9 11.0 11.4 11.8 .... Monthly Value 9.3 11.1 12.9 9.3 11.5 13.5 ----------------------------------------------------------------- -----Data not available. ~ ~'f ~ Appendix Table 13 continued ----------------------------------------------------------------- August 1984 ----------------------------------------------------------------- Intragravel Surface water Date -------------------------------------- Min Mean Max Min Mean Max ----------------------------------------------------------------- 840801 10.3 10.4 10.6 10.9 11.2 11.5 840802 10.4 10.8 11.5 11.3 11.5 11.9 840812 10.9 11.3 11.8 10.7 11.2 11.8 840813 10.8 11.2 11.6 10.6 11.2 11.9 840814 10.7 11.1 11.5 10.5 11.2 11.8 f"""840815 10.7 11.2 11.9 10.5 11.3 12.5 840816 11.5 11.8 12.3 11.6 12.1 13.0 840817 12.0 12.1 12.3 12.1 12.4 12.6 840818 11.6 11.8 12.1 11.6 11.8 12.1 840819 10.7 11.1 11.7 10.3 10.9 11.6 840820 10.2 10.4 10.7 9.9 10.2 10.4 840821 10.0 10.1 10.4 9.8 9.9 10.4 ~840822 9.5 9.7 10.0 9.2 9.5 9.9 840823 9.6 9.7 9.9 9.5 9.6 10.1 840824 8.8 9.3 9.9 8.7 9.1 9.8 "'"840825 8.0 8.5 8.9 7.6 8.2 8.7 840826 6.9 7.3 8.0 6.4 7.0 7.7 840827 5.8 6.3 7.0 5.1 5.8 6.7 ~840828 5.5 5.9 6.2 5.0 5.6 6.1 840829 5.6 6.0 6.5 5.2 5.8 6.6 840830 5.6 6.1 6.6 5.3 5.9 6.7 840831 6.0 6.3 6.6 5.6 6.1 6.6 Monthly Value 5.5 9.5 12.3 5.0 9.4 13.0 ---------------------------------------------------_.-------------- -----Data not available. Appendix Table /3 continued ------------------------------------------------------------------ September 1984 ----------------------------------------------------------------- Intragravel Surface water Date -------------------------------------- Min Mean Max Min Mean Max ~----------------------------------------------------------------- 840901 5.9 6.5 7.3 5.5 6.3 7.3 840902 6.2 6.7 7.8 6.0 6.5 7.7 P'W;> 840912 6.5 7.0 7.8 6.6 7.0 7.8 840913 7.1 7.3 7.7 7.2 7.4 7.7 840914 6.2 6.~7.4 6.3 6.9 7.5 840915 6.4 7.1 8.1 6.5 7.2 8.2 840916 6.9 7.7 8.7 7.0 7.7 8.8 840917 6.5 7.0 8.1 6.6 7.1 8.1 840918 6.9 7.1 7.4 7.0 7.2 7.4 ~ 840919 6.5 6.7 7.0 6.6 6.8 7.2 840920 5.8 6.3 7.0 5.9 6.4 7.1 840921 4.9 5.6 6.5 5.0 5.7 6.6 ~ 840922 4.0 4.8 5.5 4.1 4.9 5.6 840923 4.0 4.6 5.2 4.2 4.7 5.3 840924 4.5 4.9 5.2 4.7 5.0 5.4 840925 5.0 5.3 6.0 5.1 5.4 6.1 - 840926 5.3 5.7 6.3 5.4 5.8 6.4 840927 4.8 5.4 6.2 4.9 5.5 6.3 840928 4.0 4.8 5.6 4.2 4.9 5.8 ~. 840929 4.8 5.0 5.4 4.9 5.2 5.6 840930 5.2 5.6 6.1 5.3 5.7 6.2 Monthly Value 4.0 6.1 8.7 4.1 6.2 8.8 ----------------------------------------------------------------- ~ -----Data not available. - - Appendix Table 13 Date continued October 1984 Intragravel Surface water Min Mean Max Min Mean Max 841001 5.2 5.8 6.4 5.3 5.9 6.5 841002 5.4 5.7 6.3 5.5 5.8 6.4 841003 4.5 5.1 5.7 4.7 5.2 5.9 841004 2.9 3.7 4.8 3.0 3.8 4.9 841005 2.2 2.7 3.4 2.4 2.8 3.5 ~841006 2.5 2.8 3.2 2.6 2.9 3.3 841007 2.2 2.6 3.2 2.4 2.8 '3.3 841008 2.4 2.6 3.1 2.6 2.8 3.3 841009 3.0 3.3 4.0 3.1 3.4 4.1 841010 2.9 3.6 3.0 3.7 Monthly Value 2.2 6.4 2.4 6.5 -----Data not available. Appendix Table I~Ryan temperature recorder data summary: surface water temperatures (C)recoTded at Mainstem Susitna River at LRX 53,RM 140.1, GC S31NllW10AAC. May 1984 - Surface Water Temperature (C) Date Min Mean Max 840523 6.0 6.0 840524 5.5 5.7 6.0 840525 5.5 5.9 6.0 840526 5.0 5.4 6.0 840527 5.5 5.7 6.0 840528 5.5 6.2 6.5 840529 6.5 6.5 6.5 840530 6.5 6.7 7.0 840531 7.0 .7.5 8.0 Monthly Value 5.0 8.0 -----Data not available. - Appendix Table I~continue-d ------------------------------------------------------- June 1984 --------------------------------------------------------(C)Surface Water Temperature Date ------------------------------------,.,... Min Mean Maxi, ------------------------------------------------------- 840601 7.5 8.2 9.0 840602 8.0 8.3 9.0 840603 8.0 8.8 9.5 840604 8.5 8.9 9.5 840605 8.0 8.9 9.5 840606 8.5 8.7 9.0 840607 8.5 8.8 9.0 840608 8.0 8.6 9.0 840609 8.5 8.8 9.0 840610 8.5 9.1 9.5 840611 8.5 9.5 10.5 840612 9.5 9.6 10.0 840613 8.0 8.7 9.5 840614 7.5 8.3 9'.0 840615 7.5 8.1 9.0 840616 6.5 7.0 7.5 840617 6.5 7·.2 8.5 840618 8.0 9.2 10.5 840619 10.0 11.1 12.5 840620 11.0 11.6 12.0 840621 11.0 11.8 12.5 840622 11.5 12.1 13.0 840623 11.5 11.8 12.5 840624 11.0 11.3 11.5 840625 11.0 11.6 12.0 840626 11.5 11.6 12.0 840627 9.5 10.6 11.5 840628 9.5 9.9 10.5 840629 10.5 10.6 11.0 840630 11.0 11.4 12.0 Monthly Value 6.5 9.7 13.0 -----Data not available. - Appendix Table I~continued ------------------------------------------------------- July 1984 ------------------~------------------------------------ Surface Water Temperature (C) Date ------------------------------------ Min Mean Max ------------------------------------------------------- 840701 11.5 11.8 12.0 840702 11.0 11.5 11.5 840703 11.0 11.3 11.5 840704 11.5 11.8 12.0 840705 12.0 12.0 12.0 840706 12.0 12.3 12.5 840707 11.5 11.8 12.0 840708 11.5 11.6 12.0 840709 11.0 11.3 11.5 840710 11.0 11.4 11.5 840711 11.0 11.7 12.0 840712 11.5 11.7 12.0 840713 11.5 11.8 12.0 840714 11.5 11.6 12.0 840715 11.5 11.6 12.0 840716 11.5 11.9 12.0 840717 10.5 11.2 12.0 840718 9.5 9.7 10.5 840719 9.0 9.3 9.5 840720 9.0 9.3 9.5 840721 9.0 9.0 9.0 840722 9.0 9.2 9.5 840723 9.5 10.3 12.0 840724 11.0 11.4 11.5 840725 11.0 11.5 11.5 840726 10.0 10.5 11.0 840727 9.5 9.8 10.5 840728 10.5 10.5 11.0 840729 11.0 11.0 11.0 840730 10.0 10.7 11.0 840731 10.5 10.6 11.0 Monthly Value 9.0 11.0 12.5 -----Data not available. '70 ...... - - i I Appendix Table I~continued ------------------------------------------------------- August 1984 ------------------------------------------------------- Surface Water Temperature (C) Date ------------------------------------ Min Mean Max ------------------------------------------------------- 840801 10.5 10.7 11.0 840802 10.5 10.9 11.0 840803 11.0 11.2 12.0 840804 12.0 12.4 13.5 840805 13.0 13.2 13.5 840806 13.0 13.4 14.0 840807 12.5 13.1 13.5 840808 12.5 12.9 13.5 840809 12.0 12.4 13.0 840810 11.5 11.8 12.0 840811 11.0 11.3 11.5 840812 10.5 11.1 11.5 840813 11.0 11.3 11.5 840814 11.0 11.2 11.5 840815 11.0 11.5 12.0 840816 12.0 12.0 12.0 840817 12.0 12.3 12.5 840818 11.5 12.0 12.0 840819 10.5 10.8 i1.5 840820 10.0 10.3 10.5 840821 10.0 10.0 10.0 840822 9.5 9.8 10.0 840823 9.5 9.6 10.0 840824 8.5 9.5 840826 6.0 6.0 840827 4.5 5.0 5.5 840828 4.5 5.0 5.5 840829 5.0 5.2 5.5 840830 5.0 5.3 5.5 840831 5.5 5.5 5.5 Monthly Value 4.5 10.3 14.0 -----Data not available. Appendix Table IY continued September 1984 """ Surface Water Temperature (C) Date Min Mean Max 840901 5.5 5.7 6.0 840902 6.0 6.3 6.5 840903 6.0 6.5 7.0 840904 6.5 7.0 7.5 -840905 7.0 7.3 7.5 840906 7.5 7.9 8.5 840907 8.0 8.0 8.0 840908 7.5 7.6 8.0 ~- 840909 6.5 7.2 7.5 840910 6.5 7.0 7.5 840911 6.5 6.8 7.0 -840912 6.5 6.8 7.0 840913 7.0 7.0 7.0 840914 6.0.6.5 7.0 840915 6.5 7.0 7.5 1Jl"'!, 840916 6.5 6.9 7.0 840917 6.0 6.1 6.5 840918 5.0 5.8 6.0 -840919 4.0 4.6 5.0 840920 4.0 4.1 4.5 840921 4.0 4.3 4.5 """840922 4.0 4.3 4.5 840923 4.5 4.8 5.0 840924 4.5 4.8 5.0 840925 4.0 4.6 5.0 ~, 840926 4.0 4.0 840930 5.5 5.5 i""'! Monthly Value 4.0 6.2 8.5 -------------------------------~-----------------------.... -----Data not available. - - ~,. .... Appendix Table l~continued October 1984 Surface Water Temperature (C) Date Min Mean Max 841001 5.0 5.4 5.5 841002 5.0 5.5 5.5 841003 4.5 4.7 5.0 841004 3.0 3.4 4.0 ~841005 2.5 2.7 3.0 841006 2.5 2.7 3.0 841007 2.5 2.5 3.0 841008 2.5 2.7 3.0 841009 3.0 3.2 3.5 841010 2.0 2.6 3.0 841011 1.0 1.5 2.0 841012 1.5 1.7 2.0 841013 1.5 1.8 2.0 841014 .5 1.0 1.5 841015 0.0 .5 Monthly Value 0.0 5.5 - - -----Data not available. 73 Appendix Table 15-Datapod temperature recorder data summary: intragravel and surface water temperatures (C)recorded at Mainstem Susitna River at LRX 56,RM 142.1,GC S31N11W36BCD. June 1984 - Surface water Date Intragravel Min Mean Max Min Mean Max 840606 . 840607 840608 840609 840610 840611 840612 840613 840614 840615 840616 840617 840618 840619 840620 840621 840622 840623 840624 840625 840626 840627 840628 840629 840630 Monthly Value 5.9 5.7 5.9 6.1 6.2 6.3 6.5 6.6 6.9 6.5 6.5 6.0 6.0 6.3 6.9 7.3 7.6 8.0 7.7 7.6 7.7 7.8 7.7 7.6 7.6 5.7 5.8 6.1 6.3 6.3 6.4 6.6 7.1 7.1 6.8 6.6 6.2 6.2 6.6 7.1 7.5 7.8 8.1 7.9 7.8 7.8 8.0 7.9 7.7 7.8 7.0 6.1 6.1 6.1 6.3 6.4 6.6 6.7 7.4 7.3 7.0 6.7 • 6.5 6.3 6.9 7.3 7.7 8.0 8.2 8.0 7.8 7.9 8.2 8.0 7.8 8.1 8.2 8.2 8.1 8.0 8.2 8.5 8.4 8.9 8.3 7.3 7.5 6.7 6.3 8.0 6.3 8.4 8.5 9.3 8.6 9.8 9.0 9.8 9.2 10.0 9.5 10.8 9.6 11.0 9.0 9.9 8.1 9.4 8.1 9.3 7.0 7.7 7.0 8.5 9.0 11.0 - """ ..... - -----Data not available. """ - Appendix Table IS-continued July 1984 -----------------------------------------------------------------""":SurfaceIntragrave1 water Date -------------------------------------- Min Mean Max Min Mean Max 'r ----------------------------------------------------------------- I 840701 7.8 8.0 8.1 <"""iI 840702 7.9 8 .1 8.2 840703 8.1 8 .1 8.2 840704 8.0 8.1 8.2 840705 8.2 8.4 8.5 840706 8.4 8.6 8.7 840707 8.4 8.6 8.7 840708 8.4 8.5 8.5 11.2 11.6 840709 8.3 8.5 8.6 10.5 11.2 11.7 840710 8.3 8.4 8.6 10.5 11.0 11.3 840711 8.6 8.7 8.8 10.6 11.3 12.2 840712 8.6 8.7 8.8 10.7 11.5 12.0 840713 8.5 8.7 8.8 11.3 11.8 12.4 840714 8.7 8.9 9.0 11.3 11.6 12.1 840715 8.5 8.6 8.8 10.8 11.2 11.6 840729 8.3 8.4 11.1 11.2 840730 7.9 8.4 9.9 10.2 10.7 11.2 840731 7.8 7.9 7.9 10.3 10.6 11.1 Monthly Value 7.8 9.9 10.2 12.4 -----Data not available. """ 7S Appendix Table IS continued - ----------------------------------------------------------------- August 1984 ------------------------------------------------------------------Intragravel Surface water Date -------------------------------------- Min Mean Max Min Mean Max ------------------------------------------------------------------ 840801 7.8 7.9 7.9 10.5 10.7 11.0 840802 7.9 8.0 8.0 10.7 10.9 11.3 ~ 840803 8.0 8.0 8.1 11.0 11.3 11.9 840804 8.0 8.5 8.9 11.9 12.5 13.5 840805 8.9 9.4 9.7 13.0 13.5 14.0 ~:840806 9.5 9.9 10.2 13.1 13.7 14.3 840807 9.8 10.1 10.3 12.5 13.4 14.3 840808 9.7 10.0 10.2 12.6 13.3 14.1 840809 9.5 9.8 10.0 12.4 12.9 13.4 -840810 9.4 9.5 9.6 11.8 12.2 12.5 840811 8.8 9.2 9.4 11.2 11.9 12.3 840812 8.6 8.8 8.9 10.9 11.7 12.2 840813 8.6 8.7 8.8 10.9 11.7 12.1 840814 8.5 8.7 8.7 11.2 11.6 12.0 840815 8.4 8.6 8.7 11.5 12.0 12.8 840816 8.7 8.8 9.0 12.5 12.8 13.0 -840817 8.9 9.2 9.4 12.8 13.1 13.4 840818 9.1 9.2 9.3 12.4 12.6 12.9 840819 8.3 8.6 9.1 11.1 11.6 12.4 ""'IO'! 840820 8.1 8.2 8.4 10.7 10.9 11.2 840821 8.2 8.3 8.4 10.4 10.7 10.9 840822 7.9 8.1 8.3 10.1 10.4 10.7 840823 7.7 7.8 7.9 10.1 10.6 10.8 ~ 840824 7.4 7.6 7.8 9.4 9.9 10.6 840825 7.2 7.3 7.4 8.5 9.0 9.5 840826 6.8 7.0 7.2 7.2 7.8 8.4 ~. 840827 6.4 6.6 6.9 5.9 6.8 7.8 840828 6.4 6.5 6.5 5.9 6.7 7.2 840829 6.5 6.5 6.6 6.3 6.9 7.3 840830 6.5 6.6 6.6 6.5 6.9 7.2 Monthly Value 6.4 8.4 10.3 5.9 11.0 14.3 ----------------------------------------------------------------- -----Data not available.- 7~ ""'l- I I I Appendix Table \S continued September 1984 Surface water Date Intragravel Min Mean Max Min Mean Max 840916 7.7 8.7 7.1 8.1 I""i'840917 7.1 7.5 7.9 6.4 6.9 7.2 840918 7.4 7.7 7.8 6.8 7.0 7.1 840919 6.9 7.3 7.4 6.3 6.7 6.8 840920 6.6 6.9 7.4 5.9 6.3 6.8 840921 5.7 6.2 7.0 5.0 5.6 6.3 840922 4.9 5.4 5.8 4.4 4.8 5.2 840923 4.9 5.3 5.7 4.4 4.8 5.2 840924 5 .1 5.5 5.8 4.6 5.0 5.3 840925 5.7 6.0 6.5 5.2 5.6 6.1 840926 5.8 6.3 6.7 5.6 5.9 6.4 840927 5.6 5.9 6.4 5.2 5.7 6.1 840928 4.8 5.3 5.7 4.6 5 .1 5.5 840929 5.3 5.6 6.0 5 .1 5.5 5.9 840930 5.7 6 .1 6.7 5.6 6.0 6.5 Monthly Value 4.8 8.7 4.4 8 .1 ----------------------------------------------------------------- 1 -----Data not available. ""!" I I - -77 Appendix Table IS continued - - ------------------------------------------------------------------ October 1984 ----------------------------------------------------------------- Intragravel Surface water "'"" Date -------------------------------------- Min Mean Max Min Mean Max ------------------------------------------------------------------ 841001 5.8 6.3 6.7 5.7 6.1 6.6 841002 5.9 6.1 6.4 5.9 6.1 6.4 841003 4.9 5.5 6.1 4.9 5.5 6.0 841004 3.3 4.0 4.9 3.3 4.0 4.9 841005 2.8 3.1 3.6 2.8 3.2 3.6 841006 2.8 3.2 3.6 2.9 3.3 3.7 -841007 2.7 3.0 3.4 2.7 3.1 3.5 841008 3.0 3.3 3.7 3.1 3.5 3.9 841009 3.6 3.9 4.3 3.8 4.2 4.6 841010 2.3 3.1 3.9 2.6 3.4 4.1 841011 1.5 2.0 2.4 1.7 2.2 2.6 841012 2.0 2.3 2.7 2.2 2.6 3.1 841013 1.9 2.2 2.6 2.1 2.6 3.0 -841014 .8 1.4 2.2 1.2 1.7 2.5 841015 .4 .6 .9 .7 .9 1.2 841016 .4 .6 .9 .7 .8 .9 841017 .4 .6 .8 .7 .8 .9 841018 .4 .5 .7 .7 .8 .9 841019 .4 .5 .8 .8 .8 .9 841020 .4 .4 .5 .7 .9 .9 841021 .4 .4 .5 .8 .9 .9 841022 .4 .4 .5 .7 .9 1.0 841023 .4 .6 .7 .8 1.0 1.1 ~ 841024 .3 .5 .7 .8 1.0 1.1 841025 .4 .6 .9 .8 1.0 1.0 "'"'Monthly Value .3 2.2 6.7 .7 2.4 6.6 ----------------------------------------------------------------- -----Data not available. ~ - Appendix Table lb Ryan t~mperature recorder surface water temperatures Mainstem Susitna River above RM 148.9,GC S32N10W16ACB. May 1984 data summary: (C)recorded at Portage Creek, Surface Water Temperature (C) Date Min Mean Max 840523 4.5 6.0 840524 5.5 5.7 6.0 840525 5.5 5.8 6.0 840526 5.0 5.6 6.0 840527 6.0 6.3 7.0 840528 6.0 6.6 7.5 840529 7.0 7.1 7.5 840530 7.0 7.3 8.0 840531 7.5 7.9 8.5 Monthly Value 4.5 8.5 -----Data not available. Appendix Table \t':l continued June 1984 - Surface Water Temperature (C) Date Min Mean Max 840601 7.5 8.0 8.5 840602 8.5 8.8 9.5 840603 9.0 9.4 10.0 840604 9.0 9.5 10.0 840605 9.0 9.6 10.0 840606 9.0 9.5 10.0 840607 9.0 9.4 9.5 840608 8.5 9.3 10.0 - 840609 9.0 9.7 10.0 840610 9.5 9.8 10.5 840611 9.0 10.1 11.0 -840612 10.0 10.3 11.0 840613 8.5 9.5 10.5 840614 8.0 8.8 9.5 10"'18406158.0 8.5 9.0 840616 6.5 7.1 8.0 840617 6.5 7.5 9.0 840618 8.5 9.6 11.5 I"!"t 840619 10.5 11.5 13.0 840620 12.0 12.3 12.5 840621 11.5 12.3 13.0 840622 12.0 12.7 13.5 840623 12.0 12.5 13.0 840624 11.5 12.5 840629 10.5 11.5 - 840630 11.0 11.5 12.0 Monthly Value 6.5 9.9 13.5 ~ -------------------------------------------------------------Data not available. ~ Appendix Table Ib continued ------------------------------------------------------- July 1984 ------------------------------------------------------- Surface Water Temperature (C) Date ------------------------------------ ""'1'Min Mean Max ------------------------------------------------------- ""'I'840701 11.0 11.7 12.0 I 840702 11.0 11.4 12.0 I 840703 10.5 11.0 11.5 840704 11.0 11.6 12.5 840705 11.5 12.0 12.5 840706 12.0 12.3 12.5 840707 11.5·11.8 12.5 840708 11.5 11.8 12.0 840709 10.5 11.2 12.0 840710 10.5 11.2 11.5 840711 11.0 11.5 12.0 840712 10.5 11.4 12.0 840713 11.5 11.9 12.5 840714 11.5 11.6 12.0 840715 10.5 11.4 12.0 840716 11.0 11.7 12.0 840717 9.5 10.6 11.5 840718 9.0 9.1 9.5 840719 8.5 8.7 9.0 840720 8.5 8.8 9.0 840721 8.5 8.9 9.0 840722 8.5 9.0 9.5 840723 9.0 10.2 11.5 840724 10.5 11.5 12.0 840725 10.0 11.0 12.0 840729 10.5 11.0 840730 10.0 10.3 10.5 840731 10.0 10.1 10.5 Monthly Value 8.5 10.9 12.5 -----Data not available. Appendix Table 16 continued August 1984 - Surface Water Temperature (C) Date 840801 840802 840803 840804 840805 840806 840807 840808 840809 840810 840811 840812 840813 840814 840815 840816 840817 840818 840819 840820 840821 840822 840823 840824 840825 840826 840827 840828 840829 840830 840831 Monthly Value Min 10.0 10.0 10.5 11.5 12.5 12.5 11.5 11.5 1l.5 11.0 10.0 10.0 10.0 10.0 10.5 11.0 11.5 11.0 10.0 9.5 9.0 8.5 9.0 8.5 7.5 6.5 4.5 4.5 5.0 5.5 6.0 4.5 Mean 10.3 10.3 10.7 11.9 12.8 12.8 12.3 12.1 11.8 11.2 10.6 10.5 10.5 10.3 10.8 11.4 ·11.7 11.3 10.3 9.6 9.2 8.8 9.0 8.8 8.1 6.8 5.4 5.3 5.4 5.8 6.0 9.7 Max 10.5 10.5 11.5 13.5 13.5 13.0 13.0 13.0 12.5 11.5 11.0 11.0 11.0 10.5 11.5 12.0 12.0 11.5 11.0 10.0 9.5 .9.0 9.0 9.0 8.5 7.5 6.0 6.0 6.0 6.0 6.0 13.5 - -----Data not available. Appendix Table l6 continued ------------------------------------------------------- September 1984 ------------------------------------------------------- Surface Water Temperature (C) Date ------------------------------------ Min Mean Max ------------------------------------------------------- 840901 5.5 6.0 6.5 840902 6.5 6.7 7.0 840903 6.5 7.0 7.0 840904 7.0 7.2 7.5 840905 7.5 7.6 8.0 840906 8.0 8.1 8.5 840907 8.0 8.1 8.5 840908 7.5 7.7 8.0 840909 7.0 7.3 7.5 840910 7.0 7.2 7.5 840911 6.5 6.8 7.0 840912 7.0 7.1 7.5 840913 7.0 7.0 7.0 840914 6.5 6.8 7.0 840915 6.5 7.0 7.5 840916 7.0 7.2 7.5 840917 6.5 6.8 7.0 840918 7.0 7.0 7.0 840919 6.5 6.5 6.5 840920 6.0 6.0 6.0 840921 5.0 5.3 6.0 840922 4.0 4.4 5.0 840923 4.5 4.5 4.5 840924 4.5 4.7 5.0 r-840925 5.0 5.2 5.5 840926 5.0 5.0 5.5 840927 5.0 5.0 5.0 . 840928 4.5 5.0 Monthly Value 4.0 6.5 8.5 - - -----Data not available. Appendix Table I~Ryan temperature recorder data summary: surface water temperatures (C)recorded at Mainstem Susitna River above Fog Creek- Site 1,RM 176.8.GC S31N06W15BAC. May 1984 - Surface Water Temperature (C) Date Min Mean Max ~ 840523 3.5 4.5 840524 3.5 4.3 5.0 840525 4.0 4.5 5.0 840526 3.5 4.2 5.0 840527 4.5 4.9 5.5 840528 4.0 4.5 Monthly Value 3.5 5.5 -----Data not available. • Appendix Table '1 continued June 1984 Surface Water Temperature (C) Date Min Mean Max 840604 5.5 7.0 8.0 840605 6.5 8.0 840606 6.5 7.7 8.0 840607 7.5 8.0 8.5 840608 7.5 8.4 10.0 840609 8.5 9.1 9.5 840610 8.5 9.2 10.5 840611 8.5 9.5 10.5 840612 9.0 9.3 9.5 840613 7.5 8.3 9.5 840614 7.0 7.6 8.0 840615 7.0 7.1 8.0 840616 5.0 5.6 6.5 840617 5.0 6.0 7.5 840618 7.5 8.6 10.5 840619 9.5 10.6 12.0 840620 11.0 11.3 11.5 840621 10.5 11.3 12.0 840622 11.0 11.7 12.5 840624 10.0 10.5 11.0 840625 9.5 10.6 11.5 840626 10.5 11.0 11.5 840627 8.5 9.4 10.5 840628 8.0 8.5 9.0 840629 9.0 9.5 10.5 840630 9.5 10.3 11.0 Monthly Value 5.0 9.1 12.5 ------------------------------------------------------- -----Data not available. - ----~"---------------~----------.;.-.------------------- Appendix Table \~continued July 1984 - Surface Water Temperature (C) Date Min Mean Max 840701 10.0 10.6 11.0 840702 10.5 10.5 10.5 840703 9.5 9.9 10.5 840704 10.0 10.6 11.5 840705 10.5 11.0 11.5 840706 11.0 11.3 11.5 840707 10.0 10.6 11.0 840708 10.0 10.4 11.0 840709 9.5 9.8 10.5 840710 9.5 9.8 10.5 840711 10.0 10.2 10.5 840712 9.5 10.1 11.0 840713 10.0 10.6 11.0 840714 10.0 10.3 10.5 840715 9.5 10.0 10.5 840716 10.0 10.3 10.5 840717·8.5 9.2 10.0 840718 7.5 7.7 8.0 840719 7.0 7.4 7.5 840720 7.5 7.5 7.5 840721 7.5 7.5 7.5 840722 7.5 7.6 8.0 840723 8.0 8.9 10.5 840724 9.5 10.0 10.5 840725 10.0 10.3 10.5 840726 8.5 8.9 10.0 840727 7.5 8.4 9.5 840728 9.0 9.5-10.5 840729 9.5 10.0 10.5 840730 9.0 9.3 9.5 840731 9.0 9.3 9.5 Monthly Value 7.0 9.6 11.5 ------------------------------------------------------- -----Data not available. ""'" - Appendix Table 11 continued August 1984 Surface Water Temperature (C) Date Min Mean M.ax 840801 9.5 9.5 9.5 840802 9.5 9.7 10.0 840803 9.5 10.1 11.0 840804 10.5 11.5 13.0 840805 12.0 12.3 13.0 840806 11.5 12.0 12.5 840807 11.0 11.5 12.5 840808 10.5 11.1 11.5 840809 10.5 10.9 11.5 840810 9.5 10.1 10.5 ~840811 8.0 .8.9 9.5 840812 7.0 7.5 840820 6.5 7.1 7.5 840821 7.0 7.0 7.5 840822 6.5 6.8 7.5 840823 6.5 6.5 840824 6.0 6.8 7.0 840825 6.0 6.4 6.5 840826 4.5 6.0 Monthly Value 4.5 13.0 -----------~------------------------------------------- -----Data not available. Appendix Table \S'Ryan temperature recorder data summary: surface water temperatures (C)recorded at Mainstem Susitna River above Fog Creek- Site 2,RM 176.8,GC S31N06W15BAC. June 1984 - Surface Water Temperature (C) Date 840629 840630 Monthly Value Min 10.5 10.0 10.0 Mean 10.4 Max 11.0 11.0 11.0 -----Data not available. 88. - Appendix Table \g continued July 1984 Surface Water Temperature (C) Date Min Mean Max 840725 10.5 10.7 11.0 840726 9.0 9.5 10.5 840727 8.5 9.3 10.5 840728 9.5 10.3 11.5 840729 10.0 10.6 11.0 840730 9.5 9.8 10.0 840731 9.5 9.5 10.0 Monthly Value 8.5 11.5 -----Data not available. Appendix Table I ~continued August 1984 Surface Water Temperature (C) Date 840801 840806 840807 840808 840809 840810 840811 840812 840813 840814 840818 840826 840827 Monthly Value Min 900 11.5 11.0 10.5 10.5 10.5 9.5 9.0 8.5 8.0 800 5.0 4.0 4.0 Mean 9.3 12.0 11.7 11.2 11.0 9.9 9.6 900 4.5 Max 9.5 12.5 12.5 12.0 11.5 11.0 10.5 10.0 9.5 805 8.5 5.5 500 12.5 .,.,. -----Data not available. 90 - - Appendix Table \8 continued September 1984 Surface Water Tempe~ature (C) • Date 840914 840915 840916 840917 840918 840919 840920 840921 840922 840923 840924 840925 840926 840927 840928 840929 840930 Monthly Value Min 6.0 5.5 5.5 5.5 6.0 5.5 5.5 4.0 3.0 3.5 3.5 4.0 4.0 4.0 3.5 4.0 4.0 3.0 Mean 6.3 6.0 6.0 6.0 5.8 5.5 4.4 3.7 3.7 3.9 4.3 4.5 4.3 3.7 4.0 4.3 Max 6.0 7.0 6.5 6.5 6.0 6.0 5.5 5.0 4.0 4.0 4.0 .4.5 5.0 4.5 4.0 4.0 5.0 7.0 - -----Data not available. 9/ Appendix Table I ~continued October 1984 Surface Water Temperature (C) Date 841001 841002 841003 841004 841005 841006 841007 841008 841009 841010 841011 841012 841013 841014 841015 .Monthly Value Min 4.5 4.5 3.5 2.0 2.0 2.0 1.5 2.0 2.5 1.5 .5 1.0 .5 0.0 0.0 0.0 Mean 4.7 4.5 4.0 2.6 2.1 2.0 1.8 2.2 2.7 1.7 1.0 1.0 .9 .2 Max 5.0 5.0 4.5 3.5 2.5 2.0 2.0 2.5 3.0 2.5 1.5 1.0 1.0 .5 0.0 5.0 .,- - - Data not available. - Appendix Tablelq Datapod temperature recorder data summary: surface water temperatures (C)recorded at Mainstem Susitna River above Fog Creek -Site 2,RM 176.8,GC S31N06W16BAC. August 1984 Surface Water Temperature (C)n -,, Date Min Mean Max """I I I .... 840810 11.0 11.4 840811 9.6 10.4 11.2 840812 7.9 9.5 10.8 840813 7.4 8.5 9.1 840820 7.3 8.7 9.5 840821 8.6 8.9 9.5 840822 7.5 8.3 8.8 840823 6.5 8.0 840824 6.6 8.1 8.7 840825 7.0 7.7 8.6 840826 5.7 6.3 7.1 840827 4.1 5.0 6.0 840828 3.8 5.7 Monthly Value 3.8 11.4 -----Data not available • '13 Appendix Table ~o Ryan temperature recorder data summary: surface water temperatures (C)"recorded at Mainstem Susitna River above Fog Creek- Site 3,RM 176.8.GC S31N06W15BAC. September 1984 Surface Water Temperature (C) Date Min Mean Max ~, 840914 6.0 6.0 840915 6.0 6.5 7.5 840916 6.0 6.4 7.0 840917 5.5 6.3 6.5 840918 6.0 6.1 6.5 840919 6.0 6.0 6.0 840920 5.5 5.7 6.0 840921 4.0 4.5 5.5 840922 3.0 3.7 4.5 840923 3.5 3.8 4.0 840924 3.5 4.0 4.5 840925 4.5 4.7 5.0 840926 4.5 4.8 5.0 840927 4.0 4.4 5.0 840928 3.5 4.0 4.5 840929 4.0 4.3 4.5 840930 4.5 4.9 5.5 ~" Monthly Value 3.0 7.5 -----Data not available. - - Appendix Table :to continued October 1984 Surface Water Temperature (C) Date Min Mean Max 841001 5.0 5.2 5.5 841002 5.0 5.0 5.0 841003 3.5 4.1"4.5 841004 2.0 2.6 3.5 841005 2.0 2.0 2.0 841006 2.0 2.0 2.0 841007 1.5 1.8 2.0 841008 2.0 2.2 2.5 841009 2.5 2.7 3.0 841010 1.5 1.7 2.5 841011 .5 1.0 1.5 841012 1.0 1.0 1.0 841013 .5 1.0 1.0 841014 0.0 .1 .5 ~841015 0.0 0.0 Monthly Value 0.0 5.5 -----Data not available. ,'. Appendix Table At Ryan temperature recorder data summary: surface water temperatures (C)recorded at Mainstem Susitna River at Watana Dam Site, RM 184.2,GC S32N05W33BDB. May 1984 - Surface Water Temperature (C) Date Min Mean Max - 840523 6.0 6.0 840524 5.0 5.8 6.5 840525 5.5 5.7 6.0 840526 5.0 5.5 6.5 Monthly Value 5.0 6.5 ,.,., -----Data not available. ""'"I Appendix Table 2.1 continued June 1984 Surface Water Temperature (C) Date Min Mean Max 840613 8.5 9.2 10.0 840614 8.0 8.6 9.0 840615 8.0 8.3 8.5 840616 7.0 7.2 7.5 840617 7.0 7.8 9.0 840618 9.0 10.0 11.5 840619 10.5 11.7 13.0 P"l 840620 12.0 12.2 12.5 .!840621 11.5 12.3 13.0 840622 12.0 12.8 13.5 ~840623 12.5 12.6 13".0 840624 11.0 11.6 12.5 840625 11.0 11.9 13.0 840626 12.0 12.3 12.5 840627 10:0 10.7 12.0 840628 9.0 10.1 11.0 840629 10.5 10.7 11.0 840630 10.5 11.2 12.0 Monthly Value 7.0 13.5 -----Data not available. Surface Water Temperature (C) Append ix Tab le .J..~ Date 840701 Monthly Value continued Min 11.5 11.5 July 1984 Mean Max 11.5 11.5 - - -----Data not available. 98 - .... Appendix Table -Zl continued August 1984 Surface Water Temperature (C)~ I I I Date Min Mean Max Fj i ""'! I I """I """ 840810 10.0 10.5 840811 9.5 10.0 10.5 840812 9.5 10.0 10.5 840813 9.0 10.0 11.0 840814 9.0 10.0 840818 10.5 10.8 11.0 840819 9.0 9.5 10.0 840820 9.0 9.3 9.5 840821 8.5 8.6 9.0 840822 8.0 8.5 9.0 840823 8.5 9.0 840824 8.0 8.5 9.0 840825 6.5 7.3 8.0 840826 5.5 5.9 6.5 840827 4.5 5.2 6.0 Monthly Value 4.5 11.0 -----Data not available. Appendix Table :J..\continued ,... September 1984 Surface Water Temperature (C) Date 840914 840915 840916 840917 840918 840919 840920 840921 840922 840923 840924 840925 840926 840927 840928 840929 840930 Monthly Value Min 6.0 5.5 5.5 5.5 5.5 5.5 5.0 3.5 3.0 3.5 3.5 4.0 4.0 3.5 3.5 3.5 4.0 3.0 Mean 6.3 6.0 6.0 5.9 5.8 5.4 4.3 3.7 3.8 4.0 4.5 4.6 4.3 3.6 3.7 4.2 Max 6.0 7.0 6.5 6.5 6.0 6.0 5.5 5.0 4.0 4.0 4.5 5.0 5.0 5.0 4.0 4.0 4.5 7.0 - """ -----Data not available. /00 ..." .""'" - Appendix Table :l,\continued October 1984 Surface Water "Temperature (C) ",., I Date Min Mean Max -------------------------------------~----------------- "i 841001 4.0 4.4 5.0 841002 4.0 4.3 4.5 841003 3.0 3.3 4.0 841004 1.5 2.0 3.0 841005 1.0 1.5 2.0 841006 1.5 1.5 1.5 841007 1.5 1.7 2.0 841008 2.0 2.2 2.5 841009 2.0 2.3 2.5 841010 1.0 1.3 2.0 841011 0.0 .5 1.0 841012 .5 .7 1.0 841013 .5 .6 1.0 841014 0.0 •1 .5 841015 0.0 0.0 Monthly Value 0.0 5.0 Ii i ! -----Data not available. - fbi Appendix Table ).2..Datapod temperature recorder data summary surface water temperatures (C)recorded at Mainstem Susitna River at Watana Dam Site, RM 184.2,GC S32N05W33BDB. August 1984 - Surface Water Temperature (C) Date Min Mean Max - 840810 10.8 11.2 840811 9.5 10.3 11.5 ..... 840812 9.4 10.6 11.9 840813 9.1 11.2 840820 9.1 9.4 9.8 -840821 8.4 8.9 9.6 840822 8.2 8.7 9.5 840823 7.8 9.3 .... 840824 5.3 7.8 9.3 840825 6.9 7.5 8.4 840826 5.6 6.2 6.9 840827 4.0 4.9 6.0 ~ 840828 4.6 5.8 Monthly Value 4.0 11.9 ------------------------------------------------------- -----Data not available.~ ""'" - """ ..... Appendix Table :U,-(continued)• September 1984 Surface Water Temperature CC) Date 840917 840918 840919 840920 840921 840922 840923 840928 840929 840930 Monthly Value Min 6.7 6.7 6.3 4.9 3.3 3.5 4.4 3.6 3.9 4.4 3.3 Mean 7.4 7.2 6.8 5.9 4.3 4.1 4.1 4.9 Max 8.3 8.0 7.4 6.7 5.5 4.8 4.7 4.1 4.5 5.6 8.3 -- -----Data not available. /03 Appendix Table :U..(continued)• October 1984 - Surface Water Temperature (C) Date 841001 841002 841003 841004 841005 841006 841007 841008 841009 841010 841011 841012 841013 841014 841015 Monthly Value Min 4.7 4.5 3.2 1.7 1.3 1.3 1.2 2.0 2.4 .9 .1 .5 .5 -.2 -.2 -.2 Mean 5.2 4.9 3.9 2.6 1.9 1.7 1.6 2.3 2.8 1.7 .8 .8 .8 .0 Max 5.7 5.6 4.9 3.8 2.6 2.0 2.3 2.9 3.2 3.0 1.6 1.0 1.1 .8 -.1 5.7 - - -----Data not available. - 1""'1 I 3.3 Tables 23 to 36 -Daily and monthly mlnlmum,mean and maximum temperatures recorded at tributary sites during the 1984 open water season. /()~ Appendix Table ~3 Ryan temperature recorder data summary: surface water temperatures (C)~ecorded at the Yentna River -Site 2,RM 28.0,TRM 4.0, GC S18N07W28ABC. May 1984 - ~------------------------------------------------------ Surface Water Temperature (C) Date Min Mean Max ,..", 840524 8.5 9.0 840525 7.5 7.8 8.0 840526 6.5 7.0 7.5 840527 6.5 7.1 8.0 840528 6.5 7.3 8.0 840529 7.5 7.8 8.5 840530 7.5 7.7 8.0 840531 7.0 7.7 8.5 Monthly Value 6.5 9.0 -----Data not available. /00 - - .... - .- Appendix Table j,3 continued June 1984 Surface Water Temperature (C) Date Min Mean Max ""'r,I 840601 7.5 8.9 10.0 840602 9.5 10.4 11.5 840603 10.0 10.5 11.0 840604 10.0 10.6 11.0 840605 10.0 10.6 11.0 840606 9.0 9.6 10.5 840607 7.5 8.0 8.5 840608 7.0 7.5 8.0 840609 8.0 8.5 9.0 840610 8.5 9.0 9.5 840611 9.0 9.7 10.5 840612 10.0 10.8 11.5 840613 10.5 10.6 11.0 840614 9.0 9.3 10.5 840615 9.0 9.1 9.5 840616 8.0 8.7 9.5 840617 7.0 .7.7 8.0 840618 7.5 7.8 8.0 840619 8.0 9.0 10.5 840620 10.0 10.7 11.5 840621 10.5 11.0 11.5 840622 10.5 11.0 11.5 840623 10.5 10.7 11.5 840624 9.0 9.5 10.5 840625 9.0 9.2 9.5 840626 9.0 9.2 9.5 840627 8.0 8.3 9.0 840628 7.0 7.5 8.5 840629 7.0 7.5 8.5 840630 7.5 7.8 8.0 Monthly Value 7.0 9.3 11.5 ------------------------------------------------------- -----Data not available. /or- -_._------------------------_.......-------- I ._ Appendix Table .).:)continued July 1984 ~I - - -----------------~------------------------------------- Surface Water Temperature (C) Date Min Mean Max 840701 8.0 8.0 840726 8.5 9.0 840727 8.5 9.0 10.0 840728 9.0 9.7 10.0 840729 8.5 9.0 10.0 Monthly Value 8.5 10.0 - -----Data not available. - /6B Appendix Table ;t3 continued August 1984 Surface Water Temperature (C) Date Min Mean Max 840820 7.0 7.1 7.5 840821 7.0 7.0 7.0 840822 7.0 7.0 7.0 840823 7.0 7.4 8.0 840824 7.5 7.8 8.0 840825 7.5 7.5 8.0 840826 7.0 7.3 7.5 840827 6.5 6.8 7.0 840828 6.0 6.7 7.0 840829 6.5 6.8 7.0 840830 6.5 6.9 7.0 840831 6.0 6.2 6.5 Monthly Value 6.0 8.0 -----Data not available. Appendix Table ~.3 continued September 1984 Surface Water Temperature (C) Date 840901 840902 840903 840904 840905 840906 840907 840908 840909 840910 840911 840912 840913 840914 840915 840916 840917 840918 840919 840920 840921 840922 840923 840924 Monthly Value Min 5.5 6.0 7.0 7.0 7.0 7.5 7.5 8.0 7.5 7.0 7.0 7.0 7.0 6.~ 6.5 6.5 7.0 7.0 7.0 6.0 5.5 5.0 5.0 6.0 5.0 Mean 6.3 7.1 7.7 7.6 7.8 8.2 8.1 8.3 8.0 7.7 7.4 7.4 7.4 7.0 6.7 6.9 7.2 7.3 7.1 6.6 5.9 5.5 5.9 6.6 7.1 Max 7.0 8.0 8.5 8.5 8.5 9.0 8.5 9.0 8.5 8.5 8.0 8.0 7.5 7.0 7.0 7.5 7.5 7.5 7.5 7.0 6.0 7.0 7.0 7.0 9.0 - -----Data not available. - Appendix Table ~l..f Datapod temperature recorder data summary: surface water temperatures (C)recorded at the Yentna River -Site 2,RM 28.0, TRM 4.0,GC S18N07W28ABC. August 1984 Surface Water Temperature (C) Date Min Mean Max - -. I i 1 I 1 ;I 840811 8.4 9.2 840812 8.0 9.0 10.5 840813 8.5 9.5 10.2 840814 8.3 9.4 10.3 840815 8.6 9.6 10.8 840816 9.2 10.0 11.0 840817 9.0 9.7 10.9 840818 7.2 8.2 9.0 840819 6.6 7.0 7.5 840820 6.9 7.2 7.6 840821 6.8 7.1 7.6 840822 6.8 7.2 7.7 840823 7.1 7.6 8.6 840824 7.5 7.9 8.5 840825 7.0 7.6 8.4 840826 6.8 7.4 7.8 840827 5.8 6.8 7.6 840828 5.6 6.6 7.5 840829 5.5 7.4 840830 6.0 7.8 840831 5.7 6.9 Monthly Value 5.5 11.0 -----Data not available. 1/1 Appendix Tabl e ).!.j (continued). September 1984 Surface Water Temperature (C) Date 840912 840913 840914 840915 840916 840917 840918 840919 840920 840921 840922 840923 840924 840925 840929 840930 Monthly Value Min 7.2 6.8 6.3 6.0 6.1 6.4 6.8 6.6 6.1 5.2 4.2 4.6 6.2 6.4 6.4 6.2 4.2 Mean 7.2 6.5 6.3 6.7 7.0 7.2 7.0 6.5 5.8 5.4 5.3 6.4 Max 8.2 7.6 6.9 6.9 7.6 8.0 7.6 7.7 7.0 6.5 8.4 7.8 7 .1 6.8 6.6 6.8 8.4 "'"" - -----Data not available. /IZ-- - - - -Appendix Table ~~(cont inued)• October 1984 Surface Water Temperature (C) Date Min Mean Max ......,' ...... 841001 6.3 6.5 6.7 841002 6.0 6.3 6.7 841003 5.7 6.1 6.4 841004 4.9 5.5 6.1 841005 3.7 4.2 5.0 841006 3.6 3.8 4.0 841007 3.9 4.2 4.7 841008 4.2 4.4 4.6 841009 3.9 4.0 4.3 841010 3.2 3.5 4.0 841011 2.5 2.9 3.5 841012 2.2 2.5 2.9 841013 2.3 2.6 2.9 841014 1.3 1.9 2.7 841015 -.2 .4 1.4 841016 -.3 -.1 .3 841017 -.2 -.0 .3 841018 -.3 -.0 .2 841019 -.2 -.0 .3 841020 -.2 .0 .3 841021 -.2 .1 .3 841022 -.2 .0 .3 841023 -.2 -.0 .3 841024 -.2 .1 Monthly Value -.3 2.5 6.7 -----Data not available . //3 Appendix Table :>"S Ryan temperature recorder data summary: surface water temperatures (C)recorded at the Deshka River,RM 40.6,TRM 3.0, GCS19N06W23BDC. """ - May 1984 Surface Water Temperature (C) Date Min Mean Max - 840524 12.0 13.0 840525 11.5 12.1 13.0 840526 11.0 11.5 12.0 840527 10.0 10.9 12.0 840528 10.0 11.3 12.5 840529 11.0 11.3 11.5 840530 10.0 10.5 11.0 840531 9.5 10.8 12.0 Monthly Value 9.5 13.0 -----Data not available. /f1 - -- -Appendix Table AS continued ------------------------------------------------------- June 1984 ------------------------------------------------------- Surface Water Temperature (C) Date ------------------------------------ Min Mean Max ------------------------------------------------------- ""'"840601 11.0 12.0 13.5 840602 12.5 13.0 840607 11.5 13.3 15.0 840608 12.5 14.2 16.0 840609 13.5 14.6 16.0 840610 13.0 14.9 17.0 840611 14.0 15.6 17.5 840612 14.5 16.2 18.0 840613 15.0 15.7 16.5 840614 14.0 15.8 17.5 840615 14.0 14.8 16.5 840616 12.5 13.0 14.0 840617 12.0 12.3 13.5 840618 12.5 14.0 16.0 840619 14.5 16.0 18.0 840620 15.5 17.4 19.5 840621 16.5 18.1 19.5 840622 17.0 18.5 20.0 840623 17.5 18.3 20.0 840624 17.0 17.7 18.5 840625 16.0 17.3 18.0 840626 16.5 16.9 18.0 840627 15.5 15.9 16.5 840628 14.5 15.5 17.0 840629 16.0 16.5 17.0 840630 15.5 16.8 18.5 Monthly Value 11.0 15.6 20.0 -----Data not available. - liS' --~--------------------_...:..-----------,...--- I _ Appendix Table AS continued July 1984 -------------~----------------------------------------- Surface Water Temperature (C) Date 840701 840702 840703 840704 840705 840706 840707 840708 840709 840710 840711 840712 840713 840714 840715 Monthly Value Min 16.5 15.0 15.0 16.0 18.0 19.0 18.0 18.5 17.0 17.0 16.0 15.5 16.0 16.0 15.5 15.0 Mean 16.9 15.5 15.9 17.7 19.4 19.7 19.5 18.9 17.7 17.5 17 .2 17.0 17.2 16.7 17.0 Max 18.5 16.0 17.5 20.0 21.0 20.5 21.0 20.5 18.5 18.0 18.5 18.0 18.0 18.0 19.0 21.0 - - -----Data not available. J/~ .- Appendix Table ~5 continued August 1984 Surface Water Temperature (C) Date 840809 840810 840811 840812 840813 840814 840815 840816 840817 840818 840819 840820 840821 840822 840823 840824 840825 840826 840827 840828 840829 840830 840831 Monthly Value Min 17.0 17.0 16.0 15.5 15.0 14.5 15.0 16.0 16.0 14.5 13.0 12.5 12.0 12.0 12.5 12.0 11.0 10.0 9.5 9.0 8.5 8.5 8.0 8.0 Mean 17.7 17.1 16.8 16.6 16.5 17.0 17.1 16.5 15.1 13.5 12.6 12.2 12.4 12.8 12.4 11.5 10.3 9.6 9.3 8.8 8.9 8.5 13.5 Max 19.0 18.5 18.5 18.0 18.5 18.5 19.0 18.0 17.5 16.0 14.5 13.0 12.5 12.5 13.5 12.5 12.0 10.5 10.0 9.5 9.0 10.0 9.0 19.0 -----Data not available . ./I~ Appendix Table ).,S continued September 1984 - Surface Water Temperature (C) Date Min Mean Max 840901 7.5 8.8 10.0 -840902 8.5 9.3 10.5 840903 8.5 9.5 10.5 840904 9.0 9.7 10.5 840905 8.5 9.6 11.0 840906 8.5 9.8 11.0 840907 9.5 10.:1 11.0 840908 10.0 11.1 12.5 840909 10.0 11.0 12.0 840910 10.0 10.8 12.0 840911 9.0 10.3 11.5 840912 9.0 9.5 10.0 840913 9.5 9.7 10.0 840914 9.0 9.6 10.0 Monthly Value 7.5 12.5 - -----Data not available. '""" - 1/8 ------------------------------_.0 Appendix Table J..5 continued October 1984 Surface Water Temperature (C) Date Min Mean Max ~841017 0.0 0.0 841018 0.0 0.0 0.0 841019 0.0 0.0 0.0 841020 0.0 0.0 0.0 841021 0.0 0.0 0.0 841022 0.0 0.0 0.0 841023 0.0 0.0 0.0 841024 0.0 0.0 Monthly Value 0.0 0.0 -----Data not available. - //1 -------_._----"--------- Appendix Table 2.,Datapod temperature recorder data summary surface water temperatures (C)recorded at Deshka River.RM 40.6,TRM 3.0,S19N06W23BDC. October 1984 - Surface Water Temperature (C) Date Min Mean Max 841001 7.2 7.7 8.0 841002 7.1 7.6 8.5 ...,841003 6.1 7.1 8.0 841004 4.5 5.8 6.8 841005 4.2 4.7 5.3 841006 4.2 4.9 5.5 ~ 841007 4.5 500 5.5 841008 4.5 4.8 5.0 841009 3.8 4.7 5.5 841010 3.2 3.9 4.6 841011 2.8 3.2 3.5 841012 2.0 2.8 3.7 841013 1.5 2.2 2.9 Il\lSt 841014 .4 1.4 2.1 841015 -.1 .4 1.1 -Monthly Value -.1 8.5 -------------------------------------------------------- -----Data not available • - - Appendix Table ),.'}Ryan temperature recorder data summary: surface water temperatures (C)recorded at the Kashwitna River,RM 60.9,TRM 0.1, GC S21N06W13AAC. May 1984 Surface Water Temperature (C) - ,- I I I Date 840525 840526 840527 840528 840529 840530 840531 Monthly Value Min 8.0 7.5 7.0 8.0 9.5 8.5 7.5 7.0 Mean 8.8 8.2 8.0 9.6 9.9 8.8 9.0 Max 9.5 9.0 9.0 11.5 10.5 9.5 10.5 11.5 - - .-or I I .., I •-----Data not available . Appendix Table 1 '1 continued ------------------------------------------------------- June 1984 ------------------------------------------------------- Surface Water Temperature (C) Date ------------------------------------ Min ...., Mean Max ------------------------------------------------------- 840601 9.5 10.8 12.5 """"840602 10.5 11.8 13.0 840603 11.0 11.9 12.5 840604 10.5 11.5 12.5 -840605 10.0 11.1 12.0 840606 9.0 9.8 11.0 840607 7.0 8.3 9.5 840608 8.0 9.5 11.5 ""'''i 840609 10.0 10.4 11.0 840610 8.0 9.5 11.0 840611 9.5 10.2 11.0 I'¢'r 840612 9.5 10.3 11.0 840613 9.0 9.4 10.0 840614 8.0 9.0 10.0 ...~" 840615 8.0 8.6 9.5 840616 7.0 7.3 7.5 840617 7.0 8.0 9.0 840618 9.0 10.2 11.5 ~ 840619 10.0 11.0 12.0 840620 10.0 10.9 11.5 840621 9.5 10.6 11.5 840621.10.0 11.2 12.5 840623 9.0 10.4 11.0 840624 8.0 9.3 11.0 840625 9.5 10.4 11.5 ~ 840626 10.0 10.5 11.0 840627 8.5 8.9 9.5 840628 8.5 9.4 10.5 840629 10.0 10.7 11.5 Monthly Value 7.0 10.0 13.0 -------------------------------------------------------- -----Data not available.- Appendix Table 2.'1-continued -------------------~----------------------------------- July 1984 ------------------------------------------------------- Surface Water Temperature (C) Date ------------------------------------ ~Min Mean Max ------------------------------------------------------- 840707 9.5 11.0 840708 9.5 10.3 11.0 840709 8.5 9.8 10.5 f"""840710 7.5 8.5 9.0 i 840711 7.5 9.2 10.5 840712 8.5 9.6 11.0 840713 9.0 9.5 10.5 r"'">t;840714 8.5 9.4 10.0I 840715 8.5 9.5 11.0 840716 10.0 10.5 11.5 ~,840717 8.0 8.8 10.0 840718 7.5 7.7 8.0 840719 7.5 7.8 8.0 840720 7.5 7.9 8.0 """840721 7.5 8.4 9.5 840722 9.0 9.8 11.0 840723 9.5 10.7 12.0,...840724 10.5 11.3 12.0 840725 9.5 10.2 11.0 840726 8.5 9.2 9.5 840727 9.0 9.8 10.5 840728 9.5 9.9 10.5 840729 8.5 9.0 9.5 840730 8.0 8.9 10.0 840731 8.5 9.6 10.5 Monthly Value 7.5 9.4 12.0 ------------------------------------------------------- n i.I ~ I I -----Data not available. Appendix Table J..17 continued August 1984 ~I -- Surface Water Temperature (C) Date Min Mean·Max -. 840801 9.0 9.4 9.5 840802 9.0 9.4 10.0 840803 9.5 9·.9 10.5 840804 9.5 10.6 11.5 840805 10.5 11.2 11.5 840806 10.0 10.8 11.5 . 840807 10.5 11.6 12.5 840808 11.0 11.8 12.5 840809 11.0 11.6 12.5 840810 10.0 10.5 11.0 840811 9.5 10.3 11.5 840812 10.0 10.8 11.5 840813 9.0 10.3 11.5 840814 9.5 10.7 12.0 840815 10.0 11.2 12.5 840816 10.5 11.5 12.5 840817 11.0 11.4 12.0 840818 10.0 10.6 11.0 840819 9.5 9.6 10.0 840820 9.0 9.2 9.5 840821 9.0 9.5 10.0 840822 9.5 9.8 10.0 840823 9.5 10.0 10.5 840824 9.0 9.6 10.0 840825 8.0 8.5 9.0 840826 7.0 7.4 8.0 840827 6.5 6.9 7.0 840828 6.0 6.5 7.0 840829 5.5 6.3 7.0 840830 5.5 6.2 7.0 840831 5.0 5.7 6.5 Monthly Value 5.0 9.6 12.5 ------------------------------------------------------- -----Data not available. - ..... Appendix Table ;l.r continued (~September 1984 ---------------------------------------~--------------- Surface Water Temperature (C) Date Min Mean Max ~, l 840901 840902 840903 840904 840905 840906 840907 840908 840909 840910 840911 840912 840913 840914 840915 840916 840917 840918 840919 840920 840921 840922 840923 840924 840925 840926 840927 840928 840929 840930 Monthly Value 5.5 5.5 6.0 6.0 6.0 6.5 7.5 7.5 7.0 7.0 7.0 6.5 7.0 7.0 6.5 6.5 7.0 7.0 6.5 5.0 4.5 3.5 4.0 4.5 5.0 5.0 5.0 5.0 5.0 5.0 3.5 6.2 6.6 7.0 6.9 7.0 7.5 8.0 8.0 7.7 7.7 7.7 7.2 7.0 7.0 7.1 7.0 7.2 7.5 6.7 5.6 4.9 4.2 4.2 4.7 5.2 5.5 5.2 5.0 5.0 5.5 6.4 7.0 7.5 7.5 7.5 8.0 8.5 ·8.5 8.5 8.5 8.5 8.5 7.5 7.0 7.0 7.5 7.5 7.5 7.5 7.0 6.0 5.0 5.0 4.5 5.0 5.5 6.0 5.5 5.0 5.0 6.0 8.5 -----Data not available. Appendix Table ~?continued October 1984 Surface Water Temperature (C) Date Min Mean Max - 841001 5.0 5.6 6.0 841002 5.5 5.7 6.0 841003 5.0 5.5 6.0 841004 3.5 4.1 5.0 841005 2.5 2.9 3.0 841006 3.0 3.2 3.5 841007 3.5 3.5 3.5 841008 3.5 3.5 3.5 841009 3.5 3.5 3.5 841010 2.5 3.0 3.5 841011 1.0 1.2 2.0 841012 1.0 1.2 1.5 841013 1.5 1.5 1.5 841014 0.0 .5 1.0 841015 0.0 0.0 0.0 841016 0.0 0.0 0.0 841017 0.0 0.0 0.0 841018 0.0 0.0 0.0 841019 0.0 0.0 0.0 841020 0.0 0.0 0.0 841021 0.0 0.0 0.0 8.41022 0.0 0.0 0.0 841023 0.0 0.0 0.0 841024 0.0 0.0 Monthly Value 0.0 1.9 6.0 ------------------------------------------------------- -----Data not available. - - Appendix Table 19 Ryan temperature recorder data summary: surface water temperatures (C)recorded at the Talkeetna River -Site 3,RM 97.2,TRM 4.0, GC S26N04W16CBA. May 1984 Surface Water Temperature (C) Date Min Mean Max - I l I ,.., I I I I 840524 6.5 7.0 840525 5.0 5.9 6.5 840526 4.5 5.2 5.5 840527 5.0 5.6 6.0 840528 4.5 6.0 7.5 840529 5.5 6.0 6.5 840530 5.5 5.9 6.5 840531 5.5 6.8 8.5 Monthly Value 4.5 8.5 -----Data not available. I')7 • o Appendix Table 0).8 continued June 1984 - Surface Water Temperature (C) Date Min Mean Max 840601 6.0 7.5 8.5 840602 5.5 7.2 8.5 840603 6.0 7.4 9.0 840604 6.0 7.6 9.0 840605 6.0 7.3 8.5 840606 6.0 6.5 8.0 840607 5.5 6.6 7.5 840608 6.5 7.3 8.5 ~ 840609 6.5 7.0 8.5 840610 6.5 7.6 9.0 840611 7.5 8.4 9.5 840612 7.5 8.4 9.5 840613 7.5 7.7 8.5 840614 6.5 7.5 8.5 840615 6.5 7.5 8.5 840616 6.0 6.4 6.5 840617 6.0 6.8 8.0 840618 7.5 8.3 9.5 - 840619 9.0 9.5 10.5 840620 9.5 10.0 10.5 840621 9.5 10.1 11.0 ""'"840622 10.5 10.9 11.5 840623 9.5 10.1 11.5 840624 8.5 9.2 10.0 840625 10.0 10.6 11.5 840626 10.0 10.6 11.5 840627 9.0 9.3 10.0 840628 8.5 9.4 10.5 ~ 840629 10.0 10.5 10.5 840630 9.5 10.4 11.5 Monthly Value 5.5 8.4 11.5 -------------------------------------------------------------Data not available. l!"'1" /?-8 ------ Appendix Table J.g continued ------------------------------------------------------- July 1984 ------------------------------------------------------- Surface Water Temperature (C) Date -------------------------------------Min Mean Max ------------------------------------------------------- ....840701 10.5 10.7 11.0 840702 9.5 9.8 10.5 840703 9.0 9.6 10.5 ~~840704 10.5 11.4 12.5 840705 11.5 11.5 12.0 840706 10.5 11.1 11.5 840707 10.5 11.1 11.5 840708 10.5 11.0 11.5 840709 9.5 9.9 10.5 840710 9.5 9.7 10.0 840711 9.5 9.8 10.5 840712 9.5 9.8 10.0 840713 9.5 9.7 10.0 840714 9.5 9.8 10.0 •840715 9.0 10.0 11.0 840716 10.0 10.5 11.0 840717 8.5 9.3 10.0 "'"',840718 8.5 8.5 8.5 840719 8.5 8.5 8.5 840720 8.5 8.5 8.5-840721 8.5 9.0 9.5 840722 9.5 9.9 11.0 840723 9.5 10.9 12.5 840724 10.5 11.2 12.0 840725 9.5 10.0 10.5 840726 9.0 9.5 10.0 840727 -9.0 9.6 10.0 840728 9.5 9.9 10.0 840729 9.0 9.2 9.5 840730 8.5 9.2 10.0 840731 9.5 9.5 9.5 Monthly Value 8.5 9.9 12.5 ------------------------------------------------------- -----Data not available. _..._._..__.......~....__~,'---r-_ Appendix Table ;1.&continued - ~' ------------------------------------------------------- August 1984 ~ ------------------------------------------------------- Surface Water Temperature (C) Date ------------------------------------~ Min Mean Max ------------------------------------------------------- 840801 9.0 9.1 9.5 - 840802 9.0 9.2 9.5 840803 9.5 9.7 10.0 840804 10.0 10.6 11.5 840805 10.0 10.8 11.5 840806 10.0 10.7 12.0 840807 10.5 11.2 11.5 840808 10.5 10.9 11.5 840809 10.5 10.9 11.0 840810 9.0 9.5 10.5 840811 9.5 9.5 1I;lm§' 840812 9.5 9.8 10.0 840813 9.5 10.0 10.5 840814 9.5 9.9 10.0 840815 10.0 10.2 10.5 840816 10.0 10.4 10.5 840817 10.0 10.3 10.5 840818 9.5 10.0 10.0 """ 840819 9.5 9.5 9.5 840820 9.5 9.5 9.5 840821 9.5 9.5 9.5 ~ 840822 9.5 9.5 9.5 840823 9.5 9.5 9.5 840824 9.0 9.2 9.5 o'JllIm.\ 840825 8.0 8.4 9.0 840826 7.0 7.3 7.5 840827 6.0 6.6 7.0 840828 5.5 6.2 6.5 840829 5.5 6.3 7.0 840830 5.5 6.2 6.5 840831 5.5 5.9 6.5 ,..", Monthly Value 5.5 9.2 12.0 -------------------------------------------------------- -----Data not available. ~ /3 0 """ Appendix Table .1..lS continued September 1984 Surface Water Temperature (C) Date Min Mean Max "..., I I 840901 6.0 6.5 7.0 840902 6.0 6.9 7.5 840903 6.0 6.9 7.5 840904 6.0 6.9 7.5 840905 6.5 7.3 8.0 840906 7.5 8.0 8.5 840907 8.0 8.1 8.5 840908 7.5 8.0 8.5 840909 7.0 7.6 8.0 840910 6.5 7.4 8.0 840911 6.5 7.3 8.0 840912 6.5 7.0 840913 7.0 7.3 7.5 840914 6.5 6.9 7.0 840915 6.5 7.1 7.5 840916 7.0 7.5 840928 6.0 6.0 840929 6.0 6.3 6.5 840930 6.0 6.3 6.5 Monthly Value 6.0 8.5 -----Data not available. ;31 -----Data not available. ".. Appendix Table ~q Ryan temperature recorder surface water temperatures the Chulitna River -Site 5, GC S27N05W05ABC. May 1984 data summary: (C)recorded at RM 98.6,TRM 11.0, Surface Water Temperature (C) Date Min Mean Max ".. I Ii i I 1 i I 840523 7.0 7.5 840524 5.5 6.1 7.5 840525 5.0 5.7 6.5 840526 5.0 5.9 7.0 840527 5.0 5.9 7.0 840528 4.5 6.4 8.5 840529 6.0 6.5 7.5 840530 5.0 6.0 7.0 840531 5.5 7.1 9.5 Monthly Value 4.5 9.5 -----Data not available. /33 Appendix Taole ~q continued June 1984 Surface Water Temperature (C) Date Min Mean Max 840601 6.5 8.0 9.5 ~ 840602 7.0 8.3 10.0 840603 7.0 8.4 10.0 840604 7.0 8.6 10.0 ~ 840605 7.0 8.5 10.0 840606 5.5 7.0 9.5 840607 5.0 6.1 7.5 840608 6.0 7.5 9.5 lIml 840609 7.0 7.5 9.0 840610 6.0 7.5 9.5 840611 6.5 8.3 10.0 -, 840612 7.5 8.6 9.5 840613 7.0 7.6 9.0 840614 5.5 7.3 9.5 840615 6.5 7.0 8.5 ~ 840616 6.0 6.0 6.5 840617 5.0 6.2 8.0 840618 6.0 7.8 10.0 ~ 840619 7.0 8.7 10.5 840620 7.5 8.5 9.5 840621 7.0 8.7 10.5 -840622 7.5 8.9 10.5 840623 6.5 7.1 9.0 840624 5.5 6.9 8.5 840625 6.5 7.9 9.5 ~ 840626 6.0 6.8 8.5 840627 6.0 6.2 7.0 840628 5.5 6.6 8.5 840629 6.5 7.8 9.0 840630 6.5 7.8 9.5 Monthly Value 5.0 7.6 10.5 ~ ------------------------------------------------------- NI1! -----Data not available . .' /3(""'" r I Appendix Table :l'1 continued '"'"' ------------------------------------------------------- July 1984 ------------------------------------------------------- Surface Water Temperature (C) Date ------------------------------------ Min Mean Max ------------------------------------------------------- 840701 6.5 8.0 9.5 840702 6.0 6.7 8.0 840703 5.5 6.7 9.0 ·840704 5.5 7.7 9.5 840705 6.5 7.7 9.0 840706 6.0 7.1 8.0 840707 5.5 6.9 8.5 840708 6.0 7.0 8.0 840709 5.0 6.5 8.0 840710 5.5 6.2 7.5 840711 5.0 6.5 9.0 840712 5.5 6.8 8.0 840713 5.5 6.4 7.5 •840714 5.5 6.8 8.0 840715 6.5 7.7 9.5 840716 6.0 6.9 8.5 840717 5.5 6.0 7.0 840718 5.5 5.7 6.5 840719 5.0 5.3 5.5 840720 5.0 5.5 6.0 840721 5.5 5.8 7.0 840722 5.5 5.9 7.0 840723 5.-5 7.4 9.5 840724 6.5 7.2 9.0 840725 5.5 5.8 6.5 840726 5.0 6.0 7.5 840727 6.0 6.7 8.0 840728 6.0 6.5 7.0 840729 5.5 5.8 6.5 840730 5.0 5.8 7.0 840731 .6.0 6.3 7.0 Monthly Value 5.0 6.5 9.5 -----Data not available. Appendix Table ~~continued August 1984 Surface Water Temperature (C) Date 840801 840802 840803 840804 840805 840806 840807 840808 840809 840810 840811 840812 840813 840814 840815 840816 840817 840818 840819 840820 840821 840822 840823 840824 840825 840826 840827 840828 840829 840830 840831 Monthly Value Min 5.5 5.5 5.5 6.0 5.5 5.0 5.5 5.5 5.0 4.5 5.0 5.0 5.0 5.0 5.0 5.5 5".5 4.5 5.0 5.0 5.5 5.0 6.0 5.5 5.5 5.0 4.0 4.0 4.0 3.5 4.0 3.5 Mean 5.8 5.8 6.3 7.0 6.4 6.4 6.9 5.8 5.7 5.8 6.5 6.5 6.4 6.3 6.5 6.5 6.1 5.0 5.2 5.2 5.8 5.5 6.3 5.8 5.5 5.3 4.9 5.0 4.5 4.4 5.8 Max 6.0 6.5 7.5 8.5 8.0 8.5 8.0 7.5 7.0 7.0 8.0 8.0 8.0 7.5 8.0 8.0 7.0 5.5 5.5 5.5 6.0 6.0 7.5 6.5 5.5 5.5 6.5 6.0 6.0 5.5 5.0 8.5 """ ~, -----Data not available. //JP Appendi~Table ~q contirtued r- I September 1984 ------------------------------------------------------- Surface Water Temperature (C) Date ------------------------------------ Min Mean M.ax --------------~--------------------------------~------- 840901 4.0 5.3 7.0 840902 4.5 5.7 7.0 840903 4.5 5.7 6.5 840904 5.0 6.1 7.0 840905 5.5 6.5 7.5 840906 5.5 6.3 7.0 840907 5.5 6.0 6.5 840908 5.0 6.1 7.0 840909 4.5 5.4 6.0 840910 4.0 5.1 6.0 840911 5.0 5.5 6.0 840912 5.0 5.3 5.5 840913 4.5 4.9 5.0 840914 4.5 4.9 5.5 840915 4.5 5.3 6.0 840916 4.5 5.6 6.5 840917 5.0 5.2 6.0 840918 5.0 5.0 5.0 840919 4.5 4.9 5.0 840920 4.0 4.5 5.0 840921 3.0 4.0 4.5 840922 3.0 3.8 4.5 840923 3.5 4.0 4.5 840924 4.0 4.5 5.0 840925 4.5 5.0 5.5 840926 4.5 5.0 5.5 840927 4.0 4.5 5.0 840928 3.5 4.2 5.0 840929 4.5 5.0 5.5 840930 5.0 5.2 5.5 Monthly Value 3.0 .5.1 7.5 -----Data not available. /3.7-· Appendix Table·~1 continued 841001 4.5 5.0 5.5 841002 4.5 4.8 5.0 841003 4.0 4.1 5.0 841004 2.5 3.0 4.0 841005 2.0 2.6 3.0 841006 3.0 3.2 3.5 841007 3.0 3.3 3.5 841008 3.0 3.3 3.5 841009 3.0 3.2 3.5 841010 2.0 2.4 3.0 841011 1.0 1.5 2.0 841012 1.5 2.1 2.5 841013 2.0 2.0 2.5 841014 .5 .8 2.0 841015 0.0 .2 .5 841016 0.0 0.0 Monthly Value 0.0 5.5 October 1984 Surface Water Temperature (C) Date Min Mean Max - - - - ~I -----Data not available. - - "'" Appendix Tab Ie .3 0 Datapod temperature recorder data summary: surface water temperatures (C)recorded at Portage Creek -Site 2,RM 148.8,TRM 0.2, GC S32NlOW25ADC. May 1984 Surface Water Temperature (C) Date Min Mean Max ..... 840525 4.5 7.5 840526 3.5 5.1 6.5 840527 4.0 5.7 8.0 840528 3.5 5.5 8.0 840529 3.5 4.9 6.0 840530 3.5 5.0 7.0 840531 3.5 6.3 9.0 Monthly Value 3.5 9.0 -----Data not available • /3( Appendix Table 30 (continued). ------------------------------------------------------ June 1984 ------------------------------------------------------ Surface Water Temperature (C)~ Date ---------------------------------- Min Mean Max ------------------------------------------------------ 840601 4.0 7.0 10.0 840602 4.0 6.7 9.5 -840603 4.0 6.6 9.0 I 840604 3.5 6.4 9.0 840605 3.5 6.3 9.0 840606 4.0 5.3 7.0 -840607 4.5 6.1 8.0 840608 4.5 6.6 9.0 840609 4.0 5.8 7.5 840610 4.5 6.4 8.5 840611 4.0 6.9 9.5 840612 5.0 6.5 8.0 840613 5.0 5.8 7.0 - 840614 3.5 6.1 8.5 840615 4.5 5.4 7.0 840616 4.5 5.0 5.5 ~ 840617 4.5 6.2 8.5 840618 4.0 6.9 10.0 840619 4.5 7.6 11.0 840620 5.0 7.3 9.5 840621 5.0 7.7 11.0 840622 5.5 8.2 11.0 840623 5.0 6.9 9.0 840624 5.0 7.2 9.0 840625 5.5 8.3 11.0 840626 6.0 7.3 9.0 ~ 840627 6.0 6.6 7.5 840628 6.0 7.8 10.0 840629 7.0 8.2 9.0 840630 6.5 8.9 11.5 ~ Monthly Value 3.5 6.8 11.5 ~ ------------------------------------------------------ -----Data not available.fII5m! liD - Appendix Table 30 (continued)• ------------------------------------------------------- July 1984 ------------------------------------------------------ Surface Water Temperature (C) Date ---------------------------------- Min Mean Max ------------------------------------------------------ f'1'18 840701 7.0 9.1 11.0 840702 7.0 8.1 9.0 !"'"840703 7.0 8.7 11.0 840704 7.5 9.5 11.5 840705 8.0 9.7 11.5 840706 8.0 9.4 10.5F"'IIl 840707 9.5 9.5 840708 7.5 9.5 840709 7.5 8.9 10.5 840710 8.0 9.2 10.0 840711 7.5 9.5 11.5 840712 7.0 9.3 11.0 840713 8.5 9.8 11.0 840714 8.0 9.5 10.5 840715 8.5 10.0 12.0 840716 9.0 10.6 12.0 840717 8.5 9.3 11.0 840718 8.0 8.3 8.5 840719 7.5 7.6 8.0 840720 7.0 7.3 7.5 840721 6.5 7.0 7.5 840722 6.5 8.1 10.0 I"""840723 7.0 9.3 12.0 840724 8.0 9.7 11.5 840725 8.5 8.9 10.5 840726 7.5 8.0 9.0 """!840727 7.5 8.6 10.5 840728 8.0 8.6 9.5 840729 7.5 7.9 8.5 840730 7.0 8.4 10.0 840731 7.5 8.4 9.0 Monthly Value 6.5 8.8 12.0 ------------------------------------------------------ -----Data not available. /'1/ Appendix Table (continued).- ------------------------------------------------------ August 1984 ------------------------------------------------------ Surface Water Temperature (C) Date ---------------------------------- Min Mean Max -------------------------------------------------------, 840801 7.5 8.1 8.5 840802 8.0 8.6 9.5 840803 8.0 9.2 10.5 ~ 840804 8.5 9.8 11.0 840805 9.0 9.8 10.5 840806 9.0 10.5 12.5 ~840807 8.0 10.3 12.5 840808 9.5 10.6 U.S 840809 9.0 10.1 11.0 840810 8.5 9.5 10.5 -8408U 8.0 9.8 U.S 840812 6.5 9.2 11.0 840813 7.0 9.5 U.S -840814 7.0 9.3 11.5 840815 7.5 10.1 12.0 840816 8.5 10.2 U.S 840817 9.5 9.9 10.5 ~ 840818 9.0 9.4 10.0 840819 8.0 8.7 9.5 840820 8.0 8.5 9.0 ~ 840821 7.5 8.3 9.0 840822 7.5 8.4 9.5 840823 7.5 8.1 8.5 -840824 6.5 7.0 8.0 840825 6.0 6.5 7.0 840826 5.0 5.7 7.0 840827 4.0 5.3 7.0 ~ 840828 3.5 5.2 7.0 840829 3.5 5.3 7.0 840830 3.5 5.1 6.5 ~ 840831 4.5 5.4 6.5 Monthly Value 3.5 8.4 12.5 ~. ------------------------------------------------------ -----Data not available.~ /tf2- Appendix Tab Ie 30 (continued)• ------------------------------------------------------ September 1984 ------------------------------------------------------ """ Surface Water Temperature (C) Date ---------------------------------- Min Mean Max ------------------------------------------------------ F'" 840901 4.0 5.6 7.5 840902 4.5 6.2 8.0 .-840903 4.0 5.7 7.0 840904 5.0 6.6 8.0 840905 6.5 7.4 9.0 840906 6.5 7.5 8.5,.-840907 6.5 7.3 8.0 840908 5.5 7.0 8.5 840909 4.5 6.5 8.0 ~840910 4.5 6.4 7.5 840911 4.5 6.0 7.5 840912 5.5 6.8 8.0 840913 6.5 7.0 7.5 840914 5.0 6.5 8.0 840915 6.5 7.3 8.5 840916 5.5 6.7 8.0 840917 5.0 6.4 7.0 840918 6.0 6.5 7.0 840919 5.5 6.0 6.5 840920 5.0 5.7 6.5 840921 3.0 4.4 5.5 840922 3.0 4.3 5.5 840923 3.5 4.7 5.5-840924 4.0 5.2 6.0 840925 5.0 5.9 6~5 840926 5.5 5.9 6.5 840927 4.0 5.1 6.0 840928 3.5 4.6 5.5 840929 5.5 6.0 6.5 840930 5.5 6.2 7.0 3.0 6.1 9.0 , Monthly Value F"i ------------------------------------------------------ I, -----Data not available. /t.f3 Appendix Table 30 (continued)• October 1984 Surface Water Temperature (C) Date Min Mean Max 841001 5.0 5.8 6.5 841002 5.5 5.8 6.5 841003 4.0 4.8 5.5 841004 2.0 3.1 4.5 841005 2.5 3.2 4.0 841006 3.5 4.0 5.0 841007 3.0 3.6 4.5 841008 3.5 4.2 5.0 841009 3.5 4.3 5.0 841010 1.5 2.4 4.0 841011 1.0 1.8 3.0 841012 3.0 3.2 3.5 841013 2.5 3.0 3.5 841014 .5 1.4 2.5 841015 .5 1.0 Monthly Value .5 6.5 -----Data not available. - ...., m';1 - Appendix Table 31 Ryan temperature recorder data summary: surface water temperatures (C)record~d at Fog Creek,RM 176.7,TRM 0.1,GC S31N06W15DBB. May.1984 Surface Water Temperature (C) Date Min Mean Max 840523 4.0 6.0 840524 2.5 3.6 5.0 840525 3.0 3.9 5.5 840526 3.0 4.2 5.5 840527 3.0 4.5 5.5 840528 2.0 4.0 ~ Monthly Val)Je 2.0 6.0 -----Data not available. I""'" ! ~--------------------- Appendix Table 31 continued - ------------------------------------------------------- June 1984 ,~ ------------------------------------------------------- Surface Water Temperature (C) Date ------------------------------------ Min Mean Max --------------------------------------------------------840604 3.5 6.5 9.5 840605 4.0 6.6 9.0 840606 5.5 6.0 7.0 840607 4.5 6.0 7.5 -840608 4.5 7.1 9.5 840609 5.0 6.5 8.0 840610 4.5 6.7 9.0 -840611 4.5 7.3 9.5 840612 6.5 7.5 8.5 840613 4.5 5.7 7.5 fi@8406143.5 6.0 8.5 840615 5.0 5.5 7.0 840616 4.0 4.5 5.0 840617 4.0 5.9 8.0 840618 4.5 7.8 11.0 840619 5.5 8.7 11.5 840620 6.5 8.3 10.0 ~ 840621 6.0 9.0 11.5 840622 7.0 9.7 12.0 840623 7.0 8.1 9.0 840624 6.0 8.3 10.5 fI1li'I1! 840625 7.0 9.5 12.0 840626 8.0 9.1 10.5 840627 7.0 7.4 8.5 ~. 840628 6.0 8.4 11.0 840629 8.0 8.6 9.5 840630 7.0 9.2 11.0 - M.onthly Value 3.5 7.4 12.0 -----Data not available.- Appendix Table ~l continued July 1984 Surface Water Temperature (C) Date Min Mean Max ---------------~--------------------------------------- 840701 7.0 9.3 11.0 840702 7.0 8.0 9.0 840703 7.0 9.0 11.0 840704 8.0 9.7 11.5 840705 7.5 9.6 11.5 840706 8.0 9.7 11.0 840707 7.0 9.3 11.0 840708 7.5 8.8 10.0 840709 7.5 8.9 10.5 840710 8.0 9.2 10.5 840711 8.0 9.2 11.0 840712 6.5 9.0 11.0 840713 8.0 9.3 11.0 840714 7.5 8.5 9.5 840715 8.0 9.2 11.0 840716 8.0 9.5 11.0 840717 8.0 8.2 9.0 840718 7.0 7.6 8.5 840719 7.0 7.7 8.5 840720 7.0 7.3 7.5 840721 7.0 7.8 9.0 840722 8.0 8.6 9.5 840723 7.5 9.9 12.0 840724 9.0 9.9 "10.5 840725 9.0 9.2 9.5 840726 8.0 8.3 8.5 840727 7.5 9.3 11.5 840728 8.5 9.3 10.0 840729 8.0 8.8 9.5 840730 7.5 8.8 10.5 840731 8.0 8.8 9.5 Monthly Value 6.5 8.9 12.0 ------------------------------------------------------- -----Data not available. Appendix Table 3\continued August 1984 """ Surface Water Tempe;ature (C) Date Min /'IB Mean Max .~ Appendix Table 31 continued --September 1984 ------------------------------------------------------- Surface Water Temperature (C) Date Min Mean Max 840901 840902 840903 840904 840905 840906 840907 840908 840909 840910 840911 840912 840913 840914 840915 840916 840917 840918 840928 840929 840930 Monthly Value 3.5 4.0 3.5 5.0 6.0 6.5 6.0 4.5 4.0 4.0 3.5 4.5 5.0 5.0 4.5 3.0 3.5 4.0 3.5 3.5 3.5 3.0 5.3 5.6 5.3 6.5 7.0 7.0 6.8· 6.0 5.7 5.6 5.0 5.5 5.6 5.2 5.1 4.5 4.7 3.9 4.2 7.0 7.0 6.5 8.0 8.5 7.5 7.5 7.5 7.5 7.0 6.5 6.5 6.0 5.5 6.0 5.5 5.5 4.5 4.0 4.5 4.5 8.5 ~' -----Data not available. /'/7 Appendix Table 3\continued October 1984 ,.,.. .w&1JJ1 Surface Water Temperature (C) Date 841001 841002 841003 841004 841005 841006 841007 841008 841009 841010 841011 841012 841013 841014 841015 Monthly Value Min 3.5 2.5 1.5 1.0 1.5 1.5 2.0 2.0 .5 .5 .5 1.0 .5 0.0 0.0 0.0 M.ean 3.8 3.3 2.6 1.6 2.1 2.2 2.5 2.7 2.1 1.0 1.3 1.7 .9 .5 Max 4.0 4.0 3.0 2.0 2.5 3.0 3.0 3.0 3.0 1.5 1.5 2.0 1.5 1.0 0.0 4.0 - -----Data not available. /~ - Appendix Table 3~Ryan temperature recorder data summary: surface water temperatures (C)recorded at Tsusena Creek,RM 181.8,TRM 0.1, GC S32N06W36ADB. May 1984 Surface Water Temperature (C) - Date Min Mean Max ..... I 840523 2.5 4.5 840524 2.0 2.8 4.0 840525 1.5 3.0 4.5 840526 2.0 3.1 4.0 840527 2.0 3.2 4.0 840528 2.0 4.3 6.5 840529 2.5 3.9 5.0 840530 3.0 4.3 5.5 840531 2.0 4.6 7.0 Monthly Value 1.5 7.0 -----Data not available . (sf Appendix Table 3~continued June 1984 Surface Water Temperature (C) Date Min Mean Max -840601 3.5 5.6 8.5 840602 2.5 5.4 8.0 840629 7.5 9.0 840630 6.5 8.7 11.0 ~ Monthly Value 2.5 11.0 -- -----Data not available. - - - ." /5~. AFpendix Table 3~continued July 1984 Surface Water Temperature (C) i i Date 840701 840702 840703 840704 840705 840706 840707 840708 840709 840710 840711 840712 840713 840714 840715 840716 840717 840718 840719 840720 840721 840722 840723 840724 840725 840726 840727. 840728 840729 840730 840731 Monthly Value Min 6.5 7.5 7.5 8.0 7.5 8.0 7.0 7.0 7.5 8.0 8.0 7.0 8.5 8.0 8.0 8.5 8.0 7.5 7.0 7.0 6.5 7.0 7.0 7.5 8.0 7.0 7.0 8.0 7.5 7.0 7.5 6.5 Mean 8.9 8.4 9.2 9.5 9.5 9.5 8.6 8.5 8.9· 9.4 9.9 9.3 9.8 9.0 9.5 10.1 8.9 7.8 7.5 7.3 7.2 8.1 9.3 9.6 8.9 7.5 8.9 8.6 8.0 8.5 8.5 8.8 Max 11.0 9.5 11.0 11.0 11.0 11.0 10.0 10.0 10.5 10.5 12.0 11.5 11.5 •10.0 11.0 11.5 10.5 8.0 8.0 8.0 8.0 10.0 11.5 11.5 10.5 8.0 11.0 9.5 8.5 10.5 9.0 12.0 -----Data not available. {53 Appendix Table 32,.continued August 1984 - Surface Water Temperature (C) Date Min Mean Max 840801 7.5 8.0 8.5 840802 7.5 8.5 10.0 840803 8.0 9.4 10.5 840804 8.0 10.5 13.5 840805 9.5 10.1 11.5 840806 8.5 10.2 12.0 840807 8.5 10.7 13.5 840808 8.5 10.5 12.5 - 840809 8.5 9.5 10.5 840810 8.0 9.0 10.0 840811 7.5 9.0 11.0 -840812 5.5 8.2 10.5 840813 6.5 8.6 11.0 840814 6.0 8.5 11.0 II"!"':840815 7.0 9.3 11.5 840816 7.5 9.3 11.0 840817 8.5 9.5 10.0 ,,840818 8.0 8.6 9.5 jIOIl!O; 840820 7.0 8.1 9.0 840821 6.5 7.5 8.0 840822 6.5 7.8 9.0 -840823 7.0 7.5 8.0 840826 5.5 7.0 840827 4.0 5.6 7.5 840828 4.0 5.4 7.0 840830 4.5 5.5 6.5 840831 5.0 5.7 6.5 Monthly Value 4.0 8.3 13.5 -------------------------------------------------------~. -----Data not avallable.-I - .ISf Append~x Table 3~continued September 1984 ---~-------------------------------- Surface Water Temperature (C) - - ~i Date 840901 840902 840903 840904 840905 840906 840907 840908 840909 840910 840911 840912 840913 840914 840915 840916 840917 840918 840919 840920 840921 840922 840923 840924 840925 840926 840927 840928 840929 840930 Monthly Value Min 4.5 5.0 4.5 6.0 6.5 7.0 6.5 5.5 5.0 4.5 4.5 5.0 6.0 5.0 5.5 4.5 4.0 5.0 4.5 4.0 2.5 2.0 3.0 3.5 4.5 4.0 3.0 2.5 4.0 4.5 2.0 Mean 6.2 6.6 6.2 7.0 7.6 7.7 7.5 6.9 6.5 6.3 6.1 6.5 6.5 5.9 6.4 5.8 4.9 5.3 5.0 4.6 3.7 3.6 3.8 4.3 4.9 4.5 3.7 3.5 4.5 4.9 5.6 Max 8.0 8.5 7.5 8.0 8.5 8.5 8.5 8.5 8.5 7.5 7.5 8.0 7.0 6.5 7.5 6.5 5.5 5.5 5.5 5.5 5.0 5.0 4.5 5.0 5.5 5.0 4.5 4.5 5.0 5.5 8.5 """I -----Data not available. ISS-- ~ppendix Table 3,;!.continued October 1984 """ - Surface Water Temperature (C) Date 841001 841002 841003 841004 841005 841006 841007 841008 841009 °841010 841011 841012 841013 841014 841015 Monthly Value Min 4.0 3.5 3.0 1.0 1.5 2.0 2.0 3.0 3.0 .5 .5 2.0 1.5 .5 0.0 0.0 Mean 4.6 4.2 3.7 2.2 2.1 2.6 2.6 3.2 3.2 1.5 1.2 2.1 2.0 .9 Max 5.5 5.0 4.5 3.5 2.5 3.0 3.0 3.5 3.5 2.5 2.0 2.5 2.5 1.5 1.0 5.5 - - - - - -----Data not available.- - ·,.... Appendix Table J~Ryan temperature recorder data summary: surface water temperatures (C)recorded at Deadhorse Creek,RM 120.9,TRM 1.0, GC S29N04W14BCB. May 1984 Surface Water Temperature (C) - Date Min Mean Max 840501 .5 .7 1.0 840502 .5 .9 1.0 840503 1.0 1.2 1.5 840504 1.0 1.2 1.5 840505 1.0 1.2 1.5 840506 1.0 1.3 1.5 840507 .5 1.1 1.5 840508 1.0 1.4 2.0 840509 1.0 1.3 2.0 840510 1.0 1.5 2.5 840511 1.0 1.6 2.5 840512 1.0 1.8 2.5 840513 1.5 2.2 3.0 840514 1.5 2.2 3.5 840515 1.5 2.5 3.5 840516 2.0 2.8 4.0 840517 2.0 3.0 4.0 840518 2.5 3.1 4.0 840519 2.5 3.3 4.5 840520 2.5 3.2 4.0 840521 2.5 3.3 4.0 840522 3.0 3.2 3.5 840523 2.0 3.2 5.0 840524 2.5 3.2 4.0 840525 2.5 3.0 4.0 840526 2.5 2.8 3.5 840527 2.0 2.9 4.0 840528 2.0 3.2 5.0 840529 2.5 3.4 4.5 840530 3.0 3.7 4.5 840531 2.5 4.1 5.5 Monthly Value .5 2.4 5.5 ------------------------------------------------------- Data not available. Appendix Table 33 .continued ------------------------------------------------------- June 1984 ------------------------------------------------------- Surface Water Temperature (C) Date ------------------------------------ Min Mean Max ------------------------------------------------------- 840601 3.0 4.3 6.0 840602 3.0 4.4 6.0 840603 3.5 4.6 6.0 840604 3.0 4.7 6.5 840605 3.5 5.4 7.0 840606 4.0 4.8 5.0 840607 4.0 5.0 6.0 840608 4.5 5.8 7.0 840609 5.5 5.8 6.0 840610 5.5 6.5 8.0 840611 6.0 7.5 8.5 840612 7.0 7.8 8.5 840613 7.0 7.5 8.0 840614 6.0 7.4 8.5 840615 6.5 6.6 7.0 840616 6.0 6.0 6.0 840617 6.0 6.7 7.5 840618 6.0 7.6 9.0 840619 7.0 8.2 9.0 840620 8.0 8.6 9.5 840621 7.5 9.0 10.0 840622 8.5 9.4 10.5 840623 8.0 8.5 9.0 840624 7.5 8.5 9.0 840625 8.5 9.0 9.5 840626 8.0 8.5 9.0 840627 8.5 8.6 9.0 840628 8.5 9.0 9.5 840629 9.0 9.5 10.0 840630 9.0 9.6 10.5 Monthly Value 3.0 7.2 10.5 -----Data not available. - ""'"' Appendix Table ~3 continued July 1984 Surface Water Temperature CC) Date Min Mean Max 840701 9.0 9.7 10.5 840702 9.0 9.1 9.5 840703 9.0 9.3 10.0 840704 9.0 9.7 10.5 840705 9.5 10.1 10.5 840706 9.5 10.1 10.5 840707 9.0 9.7 10.0 840708 9.5 9.7 10.0 840709 9.0 9.3 9.5 840710 9.0 9.3 9.5 840711 9.0 9.3 10.0 840712 8.5 9.0 9.5 840713 9.0 9.0 9.0 840714 8.5 8.9 9.5 840715 9.0 9.5 10.0 840716 9.5 10.0 10.5 840717 9.5 9.5 9.5 840718 9.0 9.0 9.5 840719 8.5 8.7 9.0 840720 8.5 8.5 8.5 840721 8.5 8.7 9.0 840722 9.0 9.3 10.0 840723 9.0 9.9 ·10.5 840724 10.0 10.3 10.5 840725 9.5 10.0 10.0 840726 9.5 9.5 840727 9.5 10.0 10.5 840728 9.5 9.8 10.0 840729 8.5 9.0 9.5 840731 9.0 9.2 9.5 Monthly·Value 8.5 9.4 10.5 ------------------------------------------------------- -----Data not available. jS; Appendix Table 33 continued· August 1984 - Surface Water Temperature (C) Date 840801 840802 840803 840804 840805 840806 840807 840808 840809. 840810 840811 Monthly Value Min 8.5 8.5 9.0 9.0 10.0 10.0 9.5 10.0 10.0 9.0 9.5 8.5 Mean 8.7 8.9 9.3 10.0 10.0 10.3 10.2 10.0 10.3 9.6 Max 9.0 9.5 9.5 11.0 10.0 11.0 10.5 10.5 10.5 10.0 10.0 11.0 - - - -----Data not available. Appendix Table 33 continued September 1984 Surface Water Temperature (C) Date Min Mean Max - 840914 6.5 7.0 840915 6.5 6.6 7.0 840916 5.5 6.2 6.5 840917 6.0 6.3 6.5 840918 6.5 6.5 6.5 840919 5.5 6.3 6.5 840920 5.0 5.2 5.5 840921 4.0 4.3 4.5 840922 4.0 4.5 5.0 840923 4.5 5.1 5.5 840924 5.5 5.7 6.0 840925 6.0 6.2 6.5 840926 5.5 5.7 6.0 840927 5.0 5.3 5.5 840928 4.5 5.0 5.5 840929 5.5 6.0 6.5 840930 6.0 6.1 6.5 Monthly Value 4.0 7.0 -----Data not available. /0/ I " Appendix Tab 1e 33 continued October 1984 - Surface Water Temperature (C) Date 841001 841002 841003 841004 841005 841006 841007 841008 841009 841010 841011 841012 841013 841014 841015 8-z.1016 841017 841018 841019 841020 841021 841022 841023 841024 841025 841026 841027 841028 841029 841030 841031 Monthly Value Min 5.5 5.5 4.5 3.5 3.0 4.0 4.0 4.5 3.5 2.5 2.0 2.0 2.0 1.0 .5 .5 .5 0.0 0.0 0.0 .5 1.0 1.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Mean 5.8 5.8 4.9 3.7 3.5 4.2 4.3 4.5 4.0 2.7 2.2 2.4 2.6 1.2 .6 .5 .5 .4 .1 .3 .7 1.2 1.3 .4 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1.9 Max 6.0 6.0 5.5 4.5 4.0 4.5 5.0 4.5 4.0 3.5 2.5 2.5 3.0 2.0 1.0 .5 .5 .5 .5 .5 1.0 1.5 1.5 1.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 6.b - """ -----Data not available. Appendix Table 33 continued November 1984 Surface Water Temperature (C) Date Min Mean Max - 841101 0.0 0.0 0.0 841102 0.0 0.0 0.0 841103 0.0 0.0 0.0 841104 0.0 0.0 0.0 841105 0.0 0.0 0.0 841106 0.0 0.0 0.0 841107 0.0 0.0 0.0 841108 0.0 0.0 0.0 841109 '0.0 0.0 0.0 841110 0.0 0.0 0.0 841111 0.0 0.0 0.0 841112 0.0 0.0 0.0 841113 0.0 0.0 0.0 841114 0.0 0.0 0.0 841115 0.0 0.0 0.0 841116 0.0 0.0 0.0 841117 0.0 0.0 0.0 841118 0.0 0.0 0.0 841119 0.0 0.0 0.0 841120 0.0 0.0 0.0 841121 0.0 0.0 0.0 841122 0.0 0.0 0.0 841123 0.0 0.0 0.0 841124 0.0 0.0 0.0 841125 0.0 0.0 0.0 841126 0.0 0.0 0.0 841127 0.0 0.0 0.0 841128 0.0 0.0 0.0 841129 0.0 0.0 Monthly Value 0.0 0.0 0.0 ------------------------------------------------------- -----Data not available. /fJ3 Appendix Table ~'f Datapod temperature recorder data summary: intragrave1 water temperatures (C)recorded at Fourth of July Creek and Plume -Site I, RM 131.1,GC S30N03W03DAC. May 1984 Plume intragrave1 Creek intragrave1 Date Min Mean Max Min Mean Max 840501 840502 840503 840504 840505 840506 840507 840508 840509 840510 840511 840512 840513 840514 840515 840516 840517 840518 840519 840520 840521 840522 840523 840524 840525 840526 840527 840528 840529 840530 840531 -.1 0.0 .1 .3 .4 .7 1.2 1.4 1.8 2.6 3.1 3.6 .1 .2 .3 .5 1.0 1.4 1.6 2.2 2.9 3.4 3.8 0.0 .2 .4 .4 .7 1.2 1.4 1.8 2.6 3.1 3.6 4.0 2.1 2.1 2.1 2.1 2.4 2.5 2.4 2.6 2.6 3.0 3.3 3.2 3.4 3.8 3.8 3.5 3.5 3.9 4.7 4.9 5.4 5.3 4.9 5.0 5.2 5.3 5.4 5.6 6.2 6.4 6.2 2.1 2.2 2.1 2.2 2.2 2.2 2.4 2.7 2.9 3.6 3.1 3.8 3.1 4.2 3.2 4.1 3.3 4.3 3.2 4.0 3.4 3.5 3.3 3.5 3.5 3.8 3.9 4.0 4.0 4.1 3.6 3.9 3.7 3.9 4.3 5.0 5.0 5.5 5.3 6.1 5.7 6.2 5.7 6.1 5.2 5.5 5.2 5.5 5.3 5.4 5.4 5.5 5.7 6.2 6.3 7.3 7.1 8.0 7.2 8.3 7.8 10.3 ... """ Monthly Value -.1 4.0 2.1 4.3 10.3 -----Data not available.- Appendix Table ~'-f continued June 1984 -------------~--------------------------------------------------- Plume Intragravel Creek intragravel Date Min Mean Max Min Mean Max 840601 3.9 4.2 4.3 6.7 8.7 10.8 840602 .4.3 4.8 5.1 6.6 8.5 10.7 840603 5.1 5.5 5.6 7.1 8.8 10.9 840604 5.3 5.5 5.5 7.8 9.4 11.0 840605 5.3 5.4 5.5 8.4 9.9 11.3 840606 5.4 5.6 5.6 9.3 10.1 11.3 840607 5.6 5.8 5.9 8.8 9.3 10.4 840608 5.8 6.0 6.0 9.5 10.3 11.1 840609 5.6 5.7 5.9 10.6 11.1 11.7 840610 5.1 5.4 5.6 10.3 10.6 10.8 840611 4.7 5.0 5.2 10.7 11.2 12.0 840612 4.7 4.8 4.8 11.9 12.5 12.9 840613 4.8 5.0 5.0 11.7 12.7 13.3 840614 4.5 4.9 5.2 10.7 11.0 11.7 840615 3.5 4.0 4.5 9.6 10.3 10.8 840616 3.2 3.5 9.4 9.7 Monthly Value 3.2 6.0 6.6 13.3 ----------------------------------------------------------------- -----Data not available. Jh~ Appendix Tab1 e 35 Datapod temperature recorder data summary: intragrave1 and surface water temperatures (C)recorded at Indian River -Site 3. RM 138.6.TRM 0.2.GC S31N02W09CAB. May 1984 - Max Surface water Min MeanMax Intragrave1 Min Mean Date -----Data not available. 840522 4.8 5.4 840523 2.8 3.5 4.5 2.4 4.7 7.8 840524 3.7 4.1 4.5 3.7 5.1 6.8 840525 3.7 4.0 4.5 4.0 5.3 7.2 840526 3.9 4.4 4.8 4.0 5.5 7.4 ~ 840527 4.1 4.7 5.1 3.7 5.6 7.0 840528 4.0 4.8 6.0 3.4 5.7 8.7 840529 4.2 5,0 6.0 3.7 5.4 7.7 840530 4.2 5.0 6.2 4.2 5.5 6.9 840531 3.9 6.0 9.2 4.0 6.4 9.9 Monthly Value 2.8 9.2 2.4 9.9 - ./10& -- - - Appendix Table 3S continued June 1984 Surface water ,~ Date Intragravel Min Mean M.ax Min Mean M.ax 840601 4.6 6.9 9.5 4.7 7.3 10.3 840602 5.5 6.8 .8.7 4.4 7.2 10.4 840603 5.6 6.5 7.5 4.5 7.1 9.8 840604 4.2 6.9 9.9 ~ Monthly Value 4.6 9.5 4.2 10.4 -----.Data not available. Appendix Table '?l~-continued .... ----------------------------------------------------------------- August 1984 -,----------------------------------------------------------------- Intragrave1 Surface water Date -------------------------------------- Min Mean Max M.in M.ean Max ------------------------------------------------------------------ 84"0811 8.4 9.8 11.9 9.1 10.6 12.7 ~ 840812 7.3 9.4 11.6 7.9 10.1 12.4 840813 7.3 9.4 11.8 7.9 10.1 12.5 840814 7.4 9.5 11.7 8.0 10.1 12.4 840815 7.6 9.7 12.3 8.2 10.4 13.0 840816 8.2 10.0 12.0 8.8 10.6 12.7 840817 9.3 9.9 11.3 9.9 10.6 11.8 840818 8.6 9.2 9.8 9.4 9.9 10.7 840819 8.4 8.8 9.5 9.0 9.5 10.1 840820 8.2 8.7 9.3 8.8 9.4 10.1 840821 7.9 8.6 9.2 8.6 9.2 9.9 840822 7.9 8.6 9.3 8.6 9.3 10.1 840823 8.2 8.6 9.1 8.8 9.1 9.8 840824 7.3 7.8 8.6 7.9 8.3 9.1 840825 7.2 7.6 7.9 7.6 8.1 8.5 ." 840826 6.7 7.1 7.7 6 .1 7.0 8.0 840827 6.1 6.7 7.6 5.3 6.4 7.9 840828 5.6 6.1 6.7 4.8 6.3 8.0 -840829 5.5 6.0 6.6 5.0 6.4 8.0 840830 5 .1 5.8 6.5 5.0 6.3 7.7 840831 5.5 5.9 6.3 5.8 6.5 7.4 ""'"Monthly Value 5 .1 8.2 12.3 4.8 8.8 13.0 -----------------------------------------------------------------""'" -----Data not available. ~ - /~8 ,... COI\l+;/lhJedAppendixTable.---.-(.)~.:>- ~ ----------------------------------------------------------------- September 1984 ,-,----------------------------------------------------------------- Intragravel Surface water Date -------------------------------------- Min Mean Max Min Mean Max ----------------------------------------------------------------- 840901 5.3 6.0 7.0 5.2 6.8 8.7 840902 5.5 6.3 7.2 5.4 7.0 8.8 840903 5.5 6.4 7.1 5.4 7.0 8.5 840904 6.0 6.7 7.8 6.3 7.6 9.3 840905 6.6 7.4 8.2 6.9 8.1 9.7 840906 7.0 7.7 8.6 7.2 8.3 10.1 840907 6.9 7.5 8.3 7.2 8.1 9.1 840908 6.6 7.4 8.2 6.8 8.0 9.3 ,2*840909 5.7 6.9 8.1 5.9 7.5 9.1 840910 5.6 6.9 8.0 5.8 7.5 9.2 840911 5.6 6.8 7.8 5.7 7.4 8.9....840912 6.1 6.8 7.6 6.6 7.5 8.7 840913 6.7 7.0 7.5 7.2 7.6 8.2 840914 5.8 6.6 7.6 6.2 7.3 8.5 840915 6.4 7.2 8.3 7.0 8.0 9.7 840916 5.9 7.1 8.2 6.1 7.7 9.2 840917 5.7 6.7 7.7 6.1 7.3 8.3 840918 6.5 6.8 7.1 7.2 7.6 7..9 840919 6.1 6.4 6.8 6.8 7.1 7.4 840920 5.3 6.0 7.0 6.0 6.8 7.9 840921 4.0 5.2 6.5 4.6 5.9 7.4 --840922 3.8 5.0 6.4 4.4 5.8 7.4 840923 4.3 5.3 6.3 5.0 6.1 7.3 840924 5.1 5.8 6.5 5.8 6.6 7.4 840925 5.6 6.1 6.8 6.3 7.0 7.8 840926 5.5 6.2 7.0 5.9 6.9 8.0 840927 4.8 5.7 6.8 5.2 6.3 7.6 840928 4.2 5.2 6.3 4.6 5.4 6.9 840929 5.6 6.0 6.5 5.6 6.0 6.6 840930 5.7 6.3 7.0 5.6 6.3 7.2 Monthly Value 3.8 6.4 8.6 4.4 7.1 10.1 ~ -I, -----Data not available. Appendix Table ~~continued ,~ ----------------------------------------------------------------- October 1984 ----------------------------------------------------------------- Intragrave1 Surface water ~ Date ------------------- ------------------- Min Mean Max Min Mean Max -----------------------------------------------------------------""" 841001 5.3 6.1 6.8 5.0 6.0 6.7 841002 5.5 5.9 6.6 5.4 5.9 6.8 841003 4.5 5.4 6.3 4.3 5.2 6 .1 841004 3.2 4.2 5.6 2.8 4.0 5.3 841005 3.4 4.0 4.8 3.3 4.0 5.0 841006 3.8 4.4 5.2 3.8 4.5 5.6 841007 3.8 4.4 5.2 3.6 4.4 5.4 841008 4.1 4.5 5.0 4.0 4.5 5.1 841009 4.1 4.5 5.1 4.0 4.5 5.5 iiOi18410102.7 3.7 5.0 2.3 3.4 4.9 841011 2.2 3.0 3.8 1.8 2.9 3.8 841012 3.2 3.6 4.3 3.4 3.8 4.9 841013 3.1 3.5 4.0 3.0 3.5 4.2 841014 1.7 2.5 3.6 1.4 2.2 3.4 841015 1.4 1.9 2.4 1.1 1.7 2.4 841016 1.4 2.0 3.1 1.4 2.0 3.1 -841017 .6 1.5 2.3 .6 1.5 2.3 841018 .4 1.1 2.0 .4 1.1 2.0 841019 .3 1.1 1.6 .4 1.1 1.6 841020 .9 1.2 1.7 .9 1.2 1.8 -841021 1.4 1.9 2.6 1.5 1.9 2.6 841022 2.4 2.9 3.6 2.4 2.9 3.6 841023 2.1 2.6 3.4 2.1 2.6 3.4 -841024 .4 1.2 2.1 .5 1.3 2.1 841025 .1 .4 .8 .2 .5 .9 841026 .1 .2 .6 · 1 .3 .6 841027 . 1 .2 .3 .1 .2 .4 - 841028 0.0 .1 .2 •1 .2 .3 841029 0.0 ~1 .3 .1 .2 .4 841030 0.0 . 1 .1 • 1 .2 .2 -841031 • 1 .1 .2 0.0 .1 .2 Monthly Value 0.0 2.5 6.8 0.0 2.5 6.8 -< ----------------------------------------------------------------- -----Data not available.~ /70 - Appendix Table .3b Datapod temperature recorder data summary: intragravel and surface water temperatures (C)recorded at Indian River -Site 4, RM 138.6,TRM 0.2,GC S~INO;l."W()qc..At3. September 1984 Date Intragravel Surface water Min Mean Max Min Mean Max -840928 840929 840930 Monthly Value 5.8 5.6 5.7 5.6 6.0 6.4 6.2 6.6 7.2 7.2 5.7 5.5 5.5 5.5 5.8 6.2 6.0 6.5 7.0 7.0 ""'", -----Data not available. /7; Appendix Table 3'continued ----------------------------------------------------------------- October 1984 ----------------------------------------------------------------- Intragravel Surface water Date -------------------------------------- Min Mean Max Min Mean Max ----------------------------------------------------------------- 841001 5.1 6.0 6.9 4.9 5.9 6.7 841002 5.5 6.0 6.9 5.3 5.8 6.8 841003 4.6 5.4 6.2 4.5 5.3 6.0 841004 3.3 4.4 5.5 3.2 4.2 5.3 841005 3.6 4.3 5.1 3.5 4.1 5.0 841006 4.0 4.7 5.6 3.9 4.5 5.5 841007 3.9 4.6 5.4 3.7 4.4 5.2 841008 4.2 4.7 5.2 4.1 4.5 5.1 .~. 841009 4.2 4.7 5.6 4.1 4.7 5.4 841010 2.9 3.8 5.0 2.7 3.6 4.8 841011 2.5 3.3 3.9 2.3 3.1 3.8 841012 3.5 4.0 5.0 3.4 3.8 4.9 lO"'- 841013 3.3 3.7 4.3 3.1 3.5 4.1 841014 2.0 2.7 3.6 1.8 2.5 3.4 841015 1.8 2.3 2.8 1.6 2.2 2.6 841016 1.9 2.4 3.3 1.7 2.2 3.2 841017 1.1 1.9 2.5 1.0 1.7 2.4 841018 1.1 1.6 2.4 .9 1.5 2.3 -841019 1.1 1.6 2.0 .9 1.5 1.8 841020 1.4 1.6 2.0 1.2 1.5 1.9 841021 1.6 2.0 2.5 1.4 1.9 2.3 841022 2.3 2.7 3.3 2.2 2.5 3.2 841023 2.2 2.5 3.2 2.0 2.4 3.0 841024 1.0 1.7 2.3 .9 1.5 2.1 841025 .8 1.0 1.4 .6 .9 1.3 841026 .8 1.1 1.6 .6 1.0 1.5 841027 ..8 1.0 1.2 .6 .9 1.1 841028 .5 .7 .9 .2 .6 .8 841029 .4 .5 .6 .2 .3 .5 ~ 841030 .4 .5 .6 .2 .4 .5 841031 .3 .4 .5 .1 .2 .3 ...... Monthly Value .3 2.8 6.9 •1 2.7 6.8 ------------------------------------------------------------------ -----Data not available., '\U'J - ,- 3.4 Tables 37 to 56 Water year weeky mlnlmum,mean and maximum temperatures recorded at mainstem Susitna River sites during the 1984 open water season. J13 Appendix Table 3'1 Weekly minimum,mean,and maximum surface water temperatures (C)recorded at Mainstem Susitna River at RM 18.5,GC S16N07W15CDC. Values were obtained from temperatures measured at two-hour intervals by a Ryan temperature recorder. ------------------------------------------------------------------- Water Starting Weekly Value (C)No.of Year Calendar ---------------------n Days in Week Date Min Mean Max Record ------------------------------------------------------------------- 34 840520 7.5 8.5 32 3 35 840527 7.0 8.3 11.0 84 7 36 840603 7.5 9.6 11.0 84 7 37 840610 8.5 9.8 11.5 84 7 38 840617 8.0 10.0 11.5 84 7 39 840624 10.0 11.0 6 1 41 840708 8.5 9.3 10.5 76 7 42 840715 7.0 8.5 40 4 43 840722 7.5 8.7 10.0 84 7 44 840729 7.5 7.9 9.5 84 7 45 840805 8.5 9.2 9.5 83 7 46 840812 9.0 9.0 1 1 47 840819 7.0 7.3 8.0 82 7 48 840826 6.0 7.5 61 6 50 840909 6.5 7.5 14 2 3 841015 0.0 0.0 55 5 4 841022 0.0 0.0 29 3 ----Data not available. /71 'II!'" - - - Appendix Table .3 &Weekly m1n1mum,mean,and maximum surface water temperatures (C)recorded at Mainstem Susitna River above the Yentna River,RM 29.5, GC S17N06W07CAD.Values were obtained from temperatures measured at two-hour intervals by a Ryan temperature recorder. ------------------------------------------------------------------- ,rn.~Water Starting Weekly Value (C)No.of Year Calendar ---------------------n Days in Week Date Min Mean Max Record ------------------------------------------------------------------- ~ I 34 840520 7.5 8.5 31 3 35 840527 7.0 8.5 11.5 84 7 ~36 840603 9.0 10.4 12.0 84 7 37 840610 8.0 10.4 12.0 84 7 38 840617 7.5 11.2 14.0 84 7 39 840624 10.0 11.3 13.0 81 7 40 840701 9.5 11.0 12.5 84 7 41 840708 10.5 11.5 9 1 48 840826 6.5 7.5 12 1 49 840902 7.0 8.3 9.5 84 7 50 840909 7.0 8.1 9.0 84 7 51 840916 5.5 7.1 8.0 84 7 52 840923 5.5 6.2 6.5 95 8 1 841001 2.0 6.5 31 3 ------------------------------------------------------------------- ~ ----Data not available. - '"" --/75 Appendix Table 3~Weekly m~nl1num,mean and maximum surface surface water temperatures (C)recorded at Mainstem Susitna River above the Yentna River,RM 29.5,GC S17N06W07CAD.Values were obtained from temperatures measured at six-hour intervals by a datapod temperature recorder. - Weekly value (C)Water Year Week Starting Calender Date Min Mean Max n No.of days in Record - 46 840812 10.2 ----12.7 34 5 47 840819 8.0 9.3 10.4 56 7 48 840826 6.2 7.4 9.0 48 6 50 840909 6.9 -----8.3 13 4 ~ 51 840916 6.3 ----8.9 20 5 -----Data not available. - Appendix Table lfO Weekly minimum,mean,and maximum surface water temperatures (C)recorded at Mainstem Susitna River above the Deshka River, RM 41.1,GC S19N06W26CBC.Values were obtained from temperatures measured at two- hour intervals by a Ryan temperature recorder. Weekly Value (C)- - Water Year Week 34 35 38 39 40 43 44 45 46 47 48 49 50 51 52 1 2 3 4 5 6 7 8 9 Starting Calendar Date 840520 840527 840603 840624 840701 840722 840729 840805 840812 840819 840826 840902 840909 840916 840923 841001 841008 841015 841022 841029 841105 841112 841119 841126 Min 7.5 6.5 8.5 10.5 10.0 9.5 9.0 10.0 10.0 8.0 6.0 7.0 6.5 5.0 5.0 2.5 1.5 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Mean 8.9 10.5 10.2 11.7 11.0 8.9 7.0 8.2 7.6 6.6 5.5 4.1 2.3 .1 0.0 0.0 0.0 0.0 0.0 Max 9.5 12.0 12.5 12.0 13.5 13.0 12.0 13.5 12.0 10.0 8.0 9.5 9.0 8.0 7.0 5.5 3.0 1.5 0.0 0.0 0.0 0.0 0.0 0.0 n 31 84 81 15 42 52 84 84 84 84 84 84 82 84 92 84 84 84 84 84 84 84 84 42 No.of Days in Record 3 7 7 2 4 5 7 7 7 7 7 7 7 7 8 7 7 7 7 7 7 7 7 4 - - ----Data not available. /77 '_L """"__"_ Appendix Table ~J Weekly minimum,mean,and maximum surface water temperatures (C)recorded at Mainstem Susitna River above the Kashwitna River, RM 61.2,GC S21N05W13ABA.Values were obtained from temperatures measured at two-hour intervals by a Ryan temperature recorder. Weekly Value (C)Water Year Week 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 1 2 3 4 Starting Calendar Date 840520 840527 840603 840610 840617 840624 840701 840708 840715 840722 840729 840805 840812 840819 840826 840902 840909 840916 840923 841001 841008 841015 841022 Min 7.0 6.5 8.0 8.0 7.5 10.0 10.0 10.0 9.0 10.0 9.5 10.0 9.5 8.0 5.5 6.5 7.0 5.0 5.0 3.5 1.5 0.0 0.0 Mean 8.8 10.3 10.3 11.6 11.6 11.9 11.3 10.4 11.5 10.4 8.8 6.6 7.9 7.5 6.9 6.1 5.2 3.2 .2 Max 9.5 12.0 12.0 12.5 14.0 12.5 13.5 12.5 12.5 11.5 12.0 13.0 11.5 10.0 8.0 9.0 9.0 8.5 7.0 7.0 4.0 1.5 .5 n 29 84 84 84 84 85 84 84 52 40 84 84 84 84 84 84 84 84 96 83 84 84 30 No.of Days in Record 3 7 7 7 7 7 7 7 5 4 7 7 7 7 7 7 7 7 8 7 7 7 3 - - ----Data not available. /78 - -. I - Appendix Table y~Weekly minimum,mean,and maximum surface water temperatures (C)recorded at Mainstem Susitna River at the Parks Hwy Bridge Center Span -Site 4,RM 83.9,GC S24N05WlSBAD. Values were obtained from temperatures measured at two-hour intervals by a Ryan temperature recorder. Weekly Value (C)Water Year Week 36 37 Starting Calendar Date 840603 840610 Min 8.0 7.0 Mean 9.2 Max 10.0 11.0 n 18 84 No.of Days in Record 2 7 - - '~ I ----Data not available. /7 'l Append ix Tab le l.j 3 Weekly m1n1mum,mean,and maximum surface water temperatures (C)recorded at Mainstem Susitna River above the Parks Highway Bridge, RM 86.9.GC S24N05WOIBCD.Values were obtained from temperatures measured at two- hour intervals by a Ryan temperature recorder. ,.., Weekly Value (C)Water Year Week Starting Calendar Date Min Mean Max n No.of Days in Record 39 840624 8.5 10.0 30 3 40 840701 7.5 9.1 10.5 84 7 41 840708 8.0 8.8 9.5 84 7 42 840715 7.0 8.3 10.5 84 7 43 840722 7.0 8.6 10.5 84 7 44 840729 8.0 8.9 10.5 84 7 45 840805 7.5 9.2 10.5 82 7 46 840812 7.0 8.7 9.5 84 7 47 840819 6.5 7.1 8.5 84 7 48 840826 4.5 5.8 7.5 82 7 49 840902 6.0 7.0 8.0 84 7 50 840909 5.5 6.2 7.5 83 7 51 840916 4.5 5.8 7.0 84 7 52 840923 4.5 5.1 6.0 77 7 ----Data not available. /?TJ - Appendix Table l..f L{Weekly minimum,mean,and maximum surface water temperatures (C)recorded at Mainstem Susitna River at Talkeetna Fishwheel Camp, RM 103.0,GC S27N05W26DDD.Values were obtained from temperatures measured at two-hour intervals by a Ryan temperature recorder. ------------------------------------------------------------------- Water Starting Weekly Value (C)No.of Year Calendar ---------------------n Days in Week Date Min Mean Max Record ------------------------------------------------------------------- 34 840520 5.5 6.5 18 2 35 840527 5~5 7.6 10.5 84 7 36 840603 8.0 9.4 11.0 84 7 37 840610 7.0 9.4 11.0 84 7 38 840617 6.5 11.0 13.5 84 7 39 840624 9.5 11.6 13 .0 87 7 40 840701 11.5 12.5 13.5 84 7 41 840708 11.0 11.9 13.0 84 7 42 840715 9.0 10.5 13.0 84 7 43 840722 9.0 10.8 12.0 80 7 44 840729 10.0 11.0 14.0 84 7 45 840805 11.0 12.7 14.5 84 7 46 840812 10.0 11.5 13.0 84 7 47 840819 7.5 9.4 11.5 84 7 48 840826 5.0 5.9 7.5 84 7 49 840902 5.5 7.8 9.0 84 7 50 840909 6.5 7.1 8.0 82 7 51 840916 6.5 8.0 18 2 52 840923 5.5 6.0 17 2 1 841001 2.5 4.2 6.0 84 7 2 841008 1.0 2.1 3.5 84 7 3 841015 0.0 .5 18 2 ------------------------------------------------------------------- ----Data not available. /6/ Appendix Table "15 Weekly minimum,mean and maximum intragravel and surface water temperatures (C)recorded at Hainstem Susitna River at LRX 9 -Site 3,RH 103.5,GC S27N05W26ADD.Values were obtained from temperatures measured at six-hour intervals by a datspod temperature recorder. 1 Water Year Week Intrag.ravel Weekly Values Surface Water Weekly Values Starting --------------------------------------------------------------------------------------------------------Ca lender Hin Mean Max No.of days Min Mean Max No.of days Date (C) (C) (C)n in record (C) (C) (C)n in record ............ ~ \'l 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 48 49 50 51 52 1 840429 840506 840513 840520 840527 840603 840610 840617 840624 840701 840708 840715 840722 840729 840805 840812 840826 840902 840909 840916 840923 841001 -.2 1.6 3.4 3.6 4.0 4.3 5.5 7.6 6.8 7.0 7.0 5.7 4.7 3.6 2.3 .4 2.8 3.7 4.5 8.2 7.6 8.4 8.5 9.3 2.3 3.5 4.1 4.9 4.7 7.6 8.3 8.6 8.7 9.2 10.0 11.1 9.7 8.7 6.8 6.2 16 23 28 24 19 11 9 o o o 21 28 28 .28 28 4 9 o o o 4 12 5 7 7 7 6 5 3 o o o 6 7 7 7 7 1 3 o o o 1 3 -.1 -.2 .1 1.9 5.4 7.9 7.1 6.5 9.8 11.0 11.5 10.4 10.0 9.1 7.8 6.7 3.0 5.6 4.6 2.2 .6 2.9 5.2 7.7 9.5 9.5 11.1 11.8 12.3 12.7 12.2 12.2 11.5 12.9 6.3 .5 2.8 6.4 6.9 11.7 11.4 11.9 13 .9 13.6 14.0 14.4 15.0 14.1 15.5 16.5 13 .0 9.6 7.3 8.2 9.0 20 28 28 28 28 27 28 28 28 28 28 28 28 28 28 4 17 1 14 22 o o 5 7 7 7 7 7 7 7 7 7 7 7 7 7 7 1 5 1 4 6 o o -----Dats not available. J J J 1 J ~J J ,.1 .J 1 I J ]]~J Appendix Table ~b Weekly m1n1mum,mean,and maximum surface water temperatures (C)recorded at Mainstem Susitna River at Curry Fishwheel Camp, RM 120.7,GC S27N04W10CBA.Values were obtained from temperatures measured at two-hour intervals by a Ryan temperature recorder. -I ------------------------------------------------------------------- Water Starting Weekly Value (C)No.of Year Calendar ---------------------n Days in Week Date Min Mean Max Record ------------------------------------------------------------------- 36 840603 8.0 8.9 10.0 63 6 37 840610 6.0 8.8 10.0 84 7 38 840617 6.0 10.4 13 .0 84 7 39 840624 9.5 11.1 12.0 84 7 40 840701 11.0 12.0 12.5 84 7 41 840708 11.0 11.6 12.0 84 7 42 840715 9.0 10.2 12.0 84 7 43 840722 9.0 10.5 11.5 84 7 44 840729 10.0 10.5 13.0 84 7 45 840805 11.0 12.2 13.5 84 7 46 840812 10.0 10.9 12.0 82 7 47 840819 6.5 9.1 10.5 84 7 48 840826 5.0 5.4 6.5 84 7 49 840902 5.5 7.1 8.0 84 7 50 840909 6.0 6.7 7.5 81 7 51 840916 4.0 5.9 7.5 84 7 52 840923 4.0 4.7 5.5 96 8 1 841001 2.5 3.8 5.5 84 7 2 841008 1.0 3.0 52 5 ------------------------------------------------------------------- ----Data not available. /83 Appendix Table 1.f'1 Weekly minimum,mean and maximum intragravel and surface water temperatures (C)recorded at Mainstem Susitna River at LRX 29 -Site 3,RH 125.9,GC S30N03W19DAB.Values were obtained from temperatures measured at six-hour intervals by a datapod temperature recorder. ----------------------------------------------------------------------------------------------------------------------------- Intragravel Weekly Values Surface Water Weekly Values Water Starting ------------------------------------------------------------------------------------------------------- Year Calender Min Mean Max No.of days Min Mean Max No.of days \leek Date (C)(C)(cl n in record (C)(C)(C)n in record ----------------------------------------------------------------------------------------------------------------------------- 34 840520 5.4 ------5.8 5 2 5.3 ------6.6 5 2 35 840527 5.4 ------5.9 5 2 5.4 ------6.6 5 2 39 840624 8.7 ------11.9 12 4 9.6 ------12.9 13 4 40 840701 9.6 12.2 12.9 24 7 11.4 12.4 13 .5 26 7 41 840708 11.0 11.4 12.0 21 6 11.2 12.0 12.9 21 6 42 840715 9.3 10.6 11.9 28 7 9.3 10.8 13.0 28 7 43 840722 9.3 10.5 11.7 28 7 9.4 11.1 12.6 28 7 44 840729 10.3 .------11.9 20 5 10.9 ------12.0 20 5 46 840812 10.7 11.5 12.3 28 7 10.5 11.6 13 .0 28 7 47 840819 8.0 9.8 11.7 28 7 7.6 9.6 11.6 28 7 48 840826 5.5 6.3 8.0 28 7 5.0 6.1 7.7 28 7-.......49 840902 6.2 ------7.8 3 1 6.0 ------7.7 3 1~50 840909 6.2 ------8.1 16 4 6.3 _...._---8.2 16 4 ~"51 840916 4.0 6.4 8.7 28 7 4.1 6.5 8.8 28 7 52 840923 4.0 5.2 6.3 31 8 4.2 5.3 6.4 31 8 1 841001 2.2 4.0 6.4 28 7 2.4 4.2 6.5 28 7 2 841008 2.4 ------4.0 9 3 2.6 ------4.1 9 3 -----Data not available. J t J B !1 J I I J ,J J I J j I J I Appendix Table I.f &Weekly m1n1mum,mean,and maximum surface water temperatures (C)recorded at Mainstem Susitna River at LRX 53,RM 140.1, GC S31N11W10AAC.Values were obtained from temperatures measured at two-hour intervals by a Ryan temperature recorder. Weekly Value (C)Water Year Week 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 1 2 3 Starting Calendar Date 840520 840527 840603 840610 840617 840624 840701 840708 840715 840722 840729 840805 840812 840819 840826 840902 840909 840916 840923 841001 841008 841015 Min 5.0 5.5 8.0 6.5 6.5 9.5 11.0 11.0 9.0 9.0 10.0 11.0 10.5 8.5 4.5 6.0 6.0 4.0 4.0 2.5 .5 0.0 Mean 7.0 8.8 8.6 10.7 11.0 11.8 11.6 10.3 10.4 11.1 12.6 11.6 10.0 5.3 7.2 6.9 5.1 3.8 2.1 Max 6.0 9.0 9.5 10.5 13.0 12.0 12.5 12.0 12.0 12.0 13.5 14.0 12.5 11.5 6.0 8.5 7.5 7.0 5.5 5.5 3.5 .5 n 41 84 84 84 84 84 84 84 84 84 84 84 82 66 78 84 84 84 45 84 84 7 No.of Days in Record 4 7 7 7 7 7 7 7 7 7 7 7 7 6 7 7 7 7 5 7 7 1 ----Data not available. Appendix Table Y<t Weekly mini~um,mean and maxi~um intragravel and surface water temperatures (C)recorded at Mainstem Susitna River at LRX 56,RH 142.1,GC S31Nl1~36BCD.Values were obtained from temperatures measured at six-hour intervals by a datapod temperature recorder. lntragravel Weekly Values Surface Water Weekly Values ........... 0<1 ~ Water Year Week 36 37 38 39 40 41 42 44 45 46 47 48 51 52 1 2 3 4 Starting Calender Date 840603 840610 840617 840624 840701 840708 840715 840729 840805 840812 840819 840826 840916 840923 841001 841008 841015 841022 Min (C) 5.7 6.2 6.0 7.6 7.8 8.3 8.5 7.8 8.8 8.4 7.2 6.4 4.9 4.8 2.7 .8 .4 .3 Mean (C) 6.7 7.1 7.8 8.3 8.6 8.1 9.7 8.8 8.0 6.9 5.7 4.5 2.6 .5 Max (C) 6.3 7.4 8.2 8.2 8.7 9.0 8.8 9.9 10.3 9.4 9.1 7.2 8.7 6.7 6.7 4.3 .9 .9 n 13 28 28 28 28 28 3 25 28 28 28 19 25 32 28 28 28 16 No.of days in record 4 7 7 7 7 7 1 7 7 7 7 5 7 8 7 7 7 4 Min (C) 8.0 6.7 6.3 10.5 10.8 10.2 11.2 10.9 8.5 5.9 4.4 4.4 2.7 1.2 .7 .7 Mean (C) 8.6 11.4 11.1 13.0 12.2 10.4 6.2 5.4 4.5 2.9 .8 Max (C) 9.8 11.0 9.0 12.4 11.6 13 .5 14.3 13.4 12.4 8.4 8.1 6.5 6.6 4.6 1.2 1.1 n 13 28 6 o o 25 3 25 28 28 28 19 25 32 28 28 28 16 No.of days in record 4 7 2 o o 7 1 7 7 7 7 5 7 8 7 7 7 4 ----~Data not available. )J ,)I )5 J :I I J ).1 ~J J J !J - Appendix Table So Weekly minimum,mean,and maximum surface water temperatures (C)recorded at Mainstem Susitna River above Portage Creek,RM 148.9. GC S32N10W16ACB.Values were obtained from temperatures measured at two-hour intervals by a Ryan temperature recorder. Weekly Value (C) ..... - Water Year Week 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 Starting Calendar Date 840520 840527 840603 840610 840617 840624 840701 840708 840715 840722 840729 840805 840812 840819 840826 840902 840909 840916 840923 Min 4.5 6.0 8.5 6.5 6.5 10.5 10.5 10.5 8.5 8.5 10.0 10.0 10.0 7.5 4.5 6.5 6.5 4.0 4.5 Mean 7.4 9.5 9.2 11.2 11.7 11.5 9.9 10.6 12.0 10.9 9.1 5.8 7.5 7.0 6.2 4.9 Max 6.0 9.5 10.0 11.0 13.5 12.5 12.5 12.5 12.0 12.0 13.5 13.5 12.0 11.0 7.5 8.5 7.5 7.5 5.5 n 44 84 84 84 84 25 84 84 84 48 78 84 84 84 84 84 84 84 65 No.of Days 1n Record 4 7 7 7 7 3 7 7 7 4 7 7 7 7 7 7 7 7 6 ----Data not available. Appendix Table 51 Weekly mlnlmum,mean,and maximum surface water temperatures (C)recorded at Mainstem Susitna River above Fog Creek -Site 1, RM 176.8,GC S31N06W15BAC.Values were obtained from temperatures measured at two-hour intervals by a Ryan temperature recorder. ""'" - - Weekly Value (C)Water Year Week Starting Calendar Date Min Mean Max n No.of Days in Record 34 840520 3.5 5.0 43 4 35 840527 4.0 5.5 18 2 36 840603 5.5 8.0 10.0 63 6 37 840610 5.0 8.1 10.5 84 7 38 840617 5.0 10.1 12.5 84 7 - 39 840624 8.0 10.0 11.5 84 7 40 840701 9.5 10.6 11.5 84 7 41 840708 9.5 10.2 11.0 84 7 '"""42 840715 7.0 8.5 10.5 84 7 43 840722 7.5 9.1 10.5 84 7 44 840729 9.0 9.9 13.0 84 7 -45 840805 8.0 11.0 13.0 84 7 46 840812 7.0 7.5 6 1 47 840819 6.0 7.5 61 6 48 840826 4.5 6.0 6 1 ~ ------------------------------------------------------------------- ~ ----Data not available. - - Appendix Table S~Weekly ml.nl.mum,mean,and maximum surface water temperatures (C)recorded at Mainstem Susitna River above Fog Creek -Site 2, RM 176.8,GC S31N06W15BAC.Values were obtained from temperatures measured at two-hour intervals by a Ryan temperature recorder. -------------------------------------------------------------------,...Water .Starting Weekly Value (C)No.of Year Calendar ---------------------n Days in Week Date Min Mean Max Record r-------------------------------------------------------------------- 39 840624 10.0 11.0 15 2 43 840722 8.5 11.5 45 4·....44 840729 9.0 11.0 48 4 45 840805 9.5 11.0 12.5 84 7 46 840812 8.0 10.0 37 4 48 840826 4.0 5.5 24 3 50 840909 5.5 7.0 17 2 51 840916 3.0 5.3 6.5 84 7 52 840923 3.5 4.1 5.0 95 8 1 841001 1.5 3.1 5.0 84 7 2 841008 0.0 1.4 3.0 84 7 3 841015 0.0 0.0 5 1 ------------------------------------------------------------------- ----Data not available. Appendix Table 53 Weekly minimum,mean and maximum surface water temperatures (C)recorded at Mainstem Susitna River above Fog Creek -Site 2, RM 176.8,GC S32N06W16BAC.Values were obtained from temperatures measured at six-hour intervals by a datapod temperature recorder. Weekly Values (C)Water Year Week Starting Calender Date Min Mean Max n No.of days in Record ..... - - ---------------------------------------------------------------------- 45 840805 9.6 ------11.4 10 2 -46 840812 7.4 -----10.8 14 2 47 840819 6.5 8.2 9.5 42 6 48 840826 3.8 -----7.1 18 3 ~ -----Data not available. - - - - Appendix Table SL.f Weekly minimum,mean,and maximum surface water temperatures (C)recorded at Mainstem Susitna River above Fog Creek -Site 3, RM 176.8,GC S31N06W15BAC.Values were obtained from temperatures measured at two-hour intervals by a Ryan temperature recorder. Weekly Value (C)Water Year Week Starting Calendar Date Min Mean Max n No.of Days in Record ;$mIo 50 840909 6.0 7.5 16 2 51 840916 3.0 5.5 7.0 84 7 52 840923 3.5 4.4 5.5 96 8 1 841001 1.5 3.2 5.5 84 7 2 841008 0.0 1.4 3.0 84 7 3 841015 0.0 0.0 5 1 ------Data not available. Appendix Table S~Weekly minimum,mean,and maximum surface water temperatures (C)recorded at Mainstem Susitna River at Watana Dam Site,RM 184.2, GC S32N05W33BDB.Values were obtained from temperatures measured at two-hour intervals by a Ryan temperature recorder. - - Weekly Value (C)Water Year Week 34 37 38 39 40 45 46 47 48 50 51 52 1 2 3 Starting Calendar Date 840520 840610 840617 840624 840701 840805 840812 840819 840826 840909 840916 840923 841001 841008 841015 Min 5.0 7.0 7.0 9.0 11.5 9.5 9.0 6.5 4.5 5.5 3.0 3.5 1.0 0.0 0.0 Mean 11.4 11.2 8.6 5.3 4.1 2.7 1.1 Max 6.5 10.0 13 .5 13.0 U.5 10.5 11.0 10.0 6.5 7.0 6.5 5.0 5.0 2.5 0.0 n 41 47 84 84 2 17 41 80 24 18 84 96 84 84 5 No.of Days in Record 4 4 7 7 1 2 4 7 2 2 7 8 7 7 1 - - - - ----Data not available. - Appendix Table 5f,Weekly minimum,mean and maximum surface water temperatures (C)recorded at Mainstem Susitna River at Watana Dam Site,RM 184.2, GC S32N05W33BDB.Values were obtained from temperatures measured at six-hour intervals by a datapod temperature recorder. Weekly Values (C)Water Year Week Starting Calender Date Min Mean Max n No.of days in Record 45 840805 9.5 ------11.5 10 2 46 840812 9.1 ------11.9 12 2 47 840819 5.3 8.4 9.8 42 6 48 840826 4.0 _._----6.9 16 3 51 840916 3.3 5.9 8.3 46 6-52 840923 3.6 5.6 20------4 1 841001 1.2 3.1 5.7 56 7 2 841008 -.2 1.3 3.2 56 7 3 841015 -.2 -------.1 4 1 -----Data not available. 3.5 Tables 57 to 70 Water year weekly mlnlmum,mean and maximum temperatures recorded at tributary sites during the 1984 open water season. - '""" - """ - - ..... ! Appendix Table S't Weekly minimum,mean,and maximum surface water temperatures (C)recorded at the Yentna River -Site 2,RM 28.0,TRM 4.0, GC Sl8N07W28ABC.Values were obtained from temperatures measured at two-hour intervals by a Ryan temperature recorder. Weekly Value (C)Water Year Week Starting Calendar Date Min Mean Max n No.of Days in Record - - ..... - 34 840520 6.5 9.0 31 3 35 840527 6.5 8.1 11.5 84 7 36 840603 7.0 9.3 11.0 84 7 37 840610 8.0 9.6 11.5 84 ...I 38 840617 7.0 9.7 11.5 84 7 39 840624 7.0 8.4 10.5 84 7 40 840701 8.0 8.0 5 1 43 840722 8.5 10.0 31 3 44 840729 7.5 8.2 10.0 84 7 45 840805 9.0 9.3 10.0 84 7 46 840812 8.5 8.6 9.0 84 7 47 840819 7.0 7.4 8.5 84 7 48 840826 5.5 6.7 7.5 84 7 49 840902 6.0 7.8 9.0 84 7 50 840909 6.5 7.4 8.5 84 7 51 840916 5.0 6.6 7.5 84 7 52 840923 5.0 7.0 24 2 ------------------------------------------------------------------- ----Data not available. 1 Appendix Table 5 &Weekly minimum,mean and maximum surface water temperatures (C)recorded at the Yentna River,RM 28.0,TRM 4.0,GC S18N07W34DBC.,Values were obtained from temperatures measured at six-hour intervals by a datapod temperature recorder. - """ ---------------------------------------------------------------------- Water Starting Weekly Values (C)No.of ~, Year Calender ---------------------n days in Week Date Min Mean Max Record ---------------------------------------------------------------------- 45 840805 8.4 ------9.2 2 1 46 840812 7.2 9.3 11.0 56 7 47 840819 6.6 7.4 8.6 56 7 "'*i 48 840826 5.5 ------7.8 34 3 50 840909 6.0 ------8.2 26 4 51 840916 4.2 6.5 8.4 56 7 52 840923 4.6 ------7.8 22 3 1 841001 3.6 5.2 6.7 56 7 2 841008 1.3 3.1 4.6 56 7 3 841015 -.3 .1 1.4 56 7 4 841022 -.2 ------.3 20 3 ~j -----Data not available. - - Appendix Table sq Weekly minimum,mean,and maximum surface water temperatures (C)recorded at the Deshka River,RM 40.6,TRH 3.0,GC S19N06W23BDC. Values were obtained from temperatures measured at two-hour intervals by a Ryan temperature recorder. Weekly Value (C)Water Year Week Starting Calendar Date Min Mean Max n No.of Days in Record 34 840520 11.0 13.0 30 3 35 840527 9.5 11.2 13.5 78 7 36 840603 11.5 16.0 36 3 37 840610 12.5 15.1 18.0 84 7-38 840617 12.0 16.4 20.0 84 7 39 840624 14.5 16.7 18.5 83 7 40 840701 15.0 17.8 21.0 84 7 41 840708 15.5 17.5 20.5 84 7 42 840715 15.5 19.0 12 1 45 840805 16.0 19.0 31 3 46 840812 14.5 16.5 19.0 84 7 47 840819 11.0 .12.5 14.5 84 7 48 840826 7.5 9.2 10.5 84 7 49 840902 8.5 9.9 12.5 84 7 50 840909 9.0 10.1 12.0 70 6 3 841015 0.0 0.0 55 5 4 841022 0.0 0.0 30 3 ----Data not available. - - /77 Appendix Table 60 Weekly minimum,mean and maximum surface surface water temperatures (C)recorded at the Deshka River,RM 40.6,TRM 3.0, GC S19N06W23BDC.Values were obtained from temperatures measured at six-hour intervals by a datapod temperature recorder. - Weekly values (C)Water Year Week Starting Calender Date Min Mean Max n No.of days in Record 1 2 3 841001 841008 841015 4.2 6.0 .4 3.3 -.1 ------ 8.5 5.5 1.1 316 336 30 7 7 1 ..... ------Data not available. /13 - - - - - - Appendix Table 'I Weekly m1n1mum,mean,and maximum surface water temperatures (C)recorded at the Kashwitna River,RM 60.9,TRM 0.1, GC S21N05W13AAC.Values were obtained from temperatures measured at two-hour intervals by a Ryan temperature recorder. ..-------------------------------------------------------------------- Water Starting Weekly Value (C)No.of Year Calendar ---------------------n Days in Week Date Min Mean Max Record ------------------------------------------------------------------- 34 840520 7.5 9.5 24 2 F"'"35 840527 7.0 9.7 13.0 84 7 36 840603 7.0 10.4 12.5 84 7 37 840610 7.0 9.2 11.0 84 7 """ 38 840617 7.0 10.3 12.5 84 7 39 840624 8.0 9.8 11.5 69 6 40 840701 9.5 11.0 6 1 41 840708 7.5 9.5 11.0 85 7 42 840715 7.5 8.6 11.5 84 7 43 840722 8.5 10.1 12.0 85 7 44 840729 8.0 9.5 11.5 84 7 ~45 840805 9.5 11.1 12.5 83 7 46 840812 9.0 10.9 12.5 84 7 47 840819 8.0 9.5 10.5 84 7 48 840826 5.0 6.5 8.0 84 7 49 840902 5.5 7.3 8.5 84 7 50 840909 6.5 7.3 8.5 84 7 51 840916 3.5 6.1 7.5 84 7 ~52 840923 4.0 5.0 6.0 96 8 1 841001 2.5 4.3 6.0 84 7 2 841008 0.0 2.1 3.5 84 7 3 841015 0.0 0.0 0.0 84 7 4 841022 0.0 0.0 30 3 ------------------------------------------------------------------- ----Data not available. - /1) Appendix Table ''''Weekly minimum,mean,and maximum surface water temperatures (C)recorded at the ~ Talkeetna River -Site 3,RM 97.2,TRM 4.0, GC S26N04W16BCA.Values were obtained from temperatures measured at two-hour intervals by a Ryan temperature recorder. ------------------------------------------------------------------- Water Starting Weekly Value (C)No.of ~ Year Calendar ---------------------n Days in Week Date Min Mean Max Record ------------------------------------------------------------------- 34 840520 4.5 7.0 28 3 35 840527 4.5 6.4 8.5 84 7 36 840603 5.5 7.1 9.0 84 7 37 840610 6.0 7.6 9.5 84 7 38 840617 6.0 9.4 11.5 84 7 39 840624 8.5 10.0 11.5 84 7 40 840701 9.0 10.8 12.5 84 7 41 840708 9.5 10.0 11.5 84 7 42 840715 8.5 9.2 11.0 84 7 43 840722 9.0 10.1 12.5 84 7 44 840729 8.5 9.5 11.5 84 7 45 840805 9.0 10.6 12.0 78 7 46 840812 9.5 10.1 10.5 81 7 -47 840819 8.0 9.3 9.5 84 7 48 840826 5.5 6.4 7.5 84 7 49 840902 6.0 7.5 8.5 84 7 50 840909 6.5 7.2 8.0 80 7 51 840916 7.0 7.5 7 1 52 840923 6.0 6.5 28 3 ~ 1 841001 2.5 4.2 6.0 84 7 2 841008 1.5 2.5 4.0 84 7 3 841015 0.0 .3 1.5 83 7 4 841022 0.0 .3 1.0 84 7 II!'l'! 5 841029 0.0 0.0 0.0 84 7 6 841105 0.0 0.0 20 2 ~ ------------------------------------------------------------------- ----Data not available.- .... ~oO Appendix Table (,3 Weekly minimum,mean,and anximum surface water temperatures (C)recorded at the Chulitna River -Site 5,RM 98.6,TRM 11.0, GC S27N05W05ABC.Values were obtained from temperatures measured at two-hour intervals by a Ryan temperature recorder. Weekly Value (C)Water Year Week 34 35 36 37 38 39 40 41 42 43 44 44 45 46 47 48 49 50 51 52 1 2 3 Starting Calendar Date 840520 840527 840603 840610 840617 840624 840701 840708 840715 840722 840729 840729 840805 840812 840819 840826 840902 840909 840916 840923 841001 841008 841015 Min 5.0 4.5 5.0 5.5 5.0 5.5 5.5 5.0 5.0 5.0 5.0 5.0 4.5 4.5 5.0 3.5 4.5 4.0 3.0 3.5 2.0 .5 0.0 Mean 6.9 7.7 7.5 8.0 7.1 7.2 6.6 6.1 6.5 6.1 6.1 6.2 6.2 5.6 4.9 6.1 5.2 4.7 4.7 3.7 2.2 Max 7.5 10.0 10.0 10.0 10.5 9.5 9.5 9.0 9.5 9.5 8.5 8.5 8.5 8.0 7.5 7.0 7.5 6.0 6.5 5.5 5.5 3.5 .5 n 40 84 84 84 84 85 84 84 84 84 84 84 84 84 84 79 84 84 84 95 84 84 19 No.of Days in Record 4 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 8 7 7 2 ----Data not available. Appendix Table b4 Weekly minimum,mean and maximum surface water temperatures CC)recorded at Portage Creek -Site 2,RM 148.8,TRM 0.2, GC S32N01W25ADC.Values were obtained from temperatures measured at one-hour intervals by a datapod depth/temperature recorder. - Weekly values (C)Water Year Week 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 1 2 3 Starting Calender Date 840520 840527 840603 840610 840617 840624 840701 840708 840715 840722 840729 840805 840812 840819 840826 840902 840909 840916 840923 841001 841008 841015 Min 3.5 3.5 3.5 3.5 4.0 5.0 ~7.0 7.0 6.5 6.5 7.0 8.0 6.5 6.0 3.5 4.0 4.5 3.0 3.5 2.0 .5 .5 Mean 5.9 6.1 6.0 7.2 7.8 9.1 9.3 8.6 8.8 8.6 10.1 9.6 7.9 5.4 6.8 6.6 5.7 5.4 4.3 2.9 Max 7.5 10.0 9.0 9.5 11.0 11.5 11.5 11.5 12.0 12.0 11.0 12.5 12.0 9.5 7.5 9.0 8.5 8.0 7.0 6.5 5.0 1.0 n 38 168 168 168 168 168 145 157 168 168 168 167 168 168 168 168 168 167 192 168 168 12 No.of days in Record 2 7 7 7 7 7 7 7 7 7 7 7 7 7 .7 7 7 7 8 7 7 1 '"'" ------Data not available. Appendix Table 'S-Weekly m1nlInum,mean,and maximum surface-water temperatures (C)recorded at Fog Creek, RM176.7,TRM 0.1,GC S31N06W15DBB.Values were obtained from temperatures measured at two-hour intervals by a Ryan temperature recorder. ------------------------------------------------------------------- Water Starting Weekly Value (C)No.of Year Calendar ---------------------n Days in Week Date Min Mean Max Record ------------------------------------------------------------------- 34 840520 2.5 6.0 43 4 35 840527 2.0 5.5 18 2 36 840603 3.5 6.4 9.5 72 6 37 840610 3.5 6.1 9.5 84 7 38 840617 4.0 8.2 12.0 84 7 39 840624 6.0 8.6 12.0 84 7 40 840701 7.0 9.2 1l.5 84 7 41 840708 6.5 9.0 11.0 84 7 42 840715 7.0 8.2 11.0 84 7 43 840722 7.5 9.2 12.0 84 7 44 840729 7.5 9.2 13.5 84 7 45 840805 7.5 10.7 13.5 83 7 46 840812 6.5 9.4 12.5 84 7 47 840819 8.0 10.0 60 5 48 840826 3.5 5.2 7.0 79 7 "..49 840902 3.5 6.3 8.5 84 7 50 840909 3.5 5.4 7.5 83 7 51 840916 3.0 5.5 30 3 52 840923 3.5 4.5 29 3 1 841001 1.0 2.6 4.0 84 7 2 841008 0.0 1.5 3.0 84 7 3 841015 0.0 0.0 1 1..... ------------------------------------------------------------------- ----Data not available. Appendix Table '6 Weekly minimum,mean,and maximum surface water temperatures (C)recorded at Tsusena Creek RM 181.8.TRM 0.1.GC S32N06W36ADB. Values were obtained from temperatures measured at two-hour intervals by a Ryan temperature recorder. -. Weekly Value (C)Water Year Week Starting Calendar Date Min Mean Max n No.of Days in Record ...,. 34 840520 1.5 4.5 43 4 35 840527 2.0 4.5 8.5 84 7 -39 840624 6.5 11.0 18 2 40 840701 6.5 9.1 11.0 84 7 41 840708 7.0 9.3 12.0 84 7 42 840715 6.5 8.3 11.5 84 7 43 840722 7.0 8.7 11.5 83 7 44 840729 7.0 8.8 13.5 84 7 45 840805 7.5 9.9 13.5 83 7 ~ 46 840812 5.5 8.9 11.5 84 7 47 840819 6.5 9.0 60 5 48 840826 4.0 5.7 8.0 79 7 49 840902 4.5 7.1 8.5 84 7 50 840909 4.5 6.3 8.5 83 7 51 840916 2.0 4.7 6.5 84 7 52 840923 2.5 4.3 5.5 96 8 """ 1 841001 1.0 3.1 5.5 84 7 2 841008 .5 2.0 3.5 84 7 3 841015 0.0 1.0 5 1 '""" ------------------------------------------------------------------- ----Data not available..~ _. .... Appendix Table '7 Weekly minimum,mean,and maximum surface water temperatures (C)recorded at Deadhorse Creek,RM 120.9.TRM 1.0.GC S29N04W14BCB. Values were obtained from temperatures measured at two-hour intervals by a Ryan .temperature recorder. Weekly Value (C)Water Year Week 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 50 51 52 1 2 3 4 5 6 7 8 9 Starting Calendar Date 840429 840506 840513 840520 840527 840603 840610 840617 840624 840701 840708 840715 840722 840729 840805 840909 840916 840923 841001 841008 841015 841022 841029 841105 841112 841119 841126 Min .5 .5 1.5 2.0 2.0 3.0 5.5 6.0 7.5 9.0 8.5 8.5 9.0 8.5 9.0 6.5 4.0 4.5 3.0 1.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Mean 1.4 2.7 3.1 3.7 5.1 7.0 8.3 9.0 9.7 9.2 9.1 9.8 9.2 10.0 5.6 5.6 4.6 2.8 .4 .4 0.0 0.0 0.0 0.0 Max 1.5 2.5 4.5 5.0 6.0 7.0 8.5 10.5 10.5 10.5 10.0 10.5 10.5 11.0 11.0 7.0 6.5 6.5 6.0 4.5 1.0 1.5 0.0 0.0 0.0 0.0 0.0 n 60 84 84 82 84 84 84 84 83 84 84 84 79 71 79 16 84 95 84 84 84 84 84 84 84 84 42 No.of Days in Record 5 7 7 7 7 7 7 ·7 7 7 7 7 7 6 7 2 7 8 7 7 7 7 7 7 7 7 4 ----Data not available. Appendix Table 'R Weekly minimum,mean and maximum intragravel water temperatures (C)recorded at Fourth of July Creek +Plume -Site 1,RH 131.1.GC S30N03W03DAC.Values were obtained from temperatures measured at six-hour intervals by a datapof temperature recorder. Plume Weekly Values Creek Water Weekly Values Water Year Week Starting Calender Date Min (C) Mean (C) Max (C)n No.of days in record Min (C) Mean (C) Max (C)n No. in record 9J ~ 31 840429 ------------------0 0 2.1 ------3.6 20 5 32 840506 ------------------0 0 2.4 3.2 4.3 28 7 33 840513 ------------------0 0 3.4 4.0 5.5 28 7 34 840520 -.1 .6 1.4 24 7 4.9 5.4 6.2 27 7 35 840527 1.4 3.3 5.1 28 7 5.4 7.3 10.8 28 7 36 840603 5.1 5.6 6.0 28 7 7.1 9.8 11.7 28 7 37 840610 3.2 4.7 5.6 26 7 9.4 11.2 13.3 26 7 -----Data not available. .~!J )I J J t .,J 1 I 1 1 ~)~1\ j j ]]j i ] Appendix Table b'"f Weekly minimum,mean and maximum intragravel and aurface water temperatures (C)recorded at Indian River -Site 3,RH 138.6,TRH 0.2,GC S31N02W09CAB.Values were obtained from temperatures measured temperatures measured at six-hour intervals by a datapod temperature recorder. Intragravel Weekly Values Surface Water Weekly Values ~ <:> -.j Water Year Week 34 35 36 45 46 47 48 49 50 51 52 1 2 3 4 5 6 Starting Calender Date 840520 840527 840603 840805 840812 840819 840826 840902 840909 840916 840923 841001 841008 841015 841022 841029 841105 Min (C) 2.8 3.9 5.5 8.4 7.3 7.2 5.1 5.5 5.6 3.8 4.2 3.2 1.7 .3 0.0 -.1 -.1 Mean (C) 5.6 9.6 8.4 6.2 7.0 6.9 6.2 5.8 4.9 3.6 1.5 1.1 .1 Max (C) 4.8 9.5 7.5 11.9 12.3 9.5 7.7 8.6 8.3 8.2 7.0 6.8 5.1 3.1 3.6 .5 .4 n 16 28 7 4 28 28 28 28 28 28 32 28 28 28 28 28 10 No.of days in record 4 7 2 1 7 7 7 7 7 7 8 7 7 7 7 7 3 Min (C) 2.4 3.4 4.2 9.1 7.9 7.6 4.8 5.4 5.7 4.4 4.6 2.8 1.4 .4 .1 0.0 0.0 Mean (C) 6.2 10.2 9.0 6.5 7.7 7.5 6.9 6.3 4.9 3.6 1.5 1.1 .1 Max (C) 7.8 10.4 9.9 12.7 13.0 10.1 8.7 10.1 9.7 9.2 8.0 6.8 5.5 3.1 3.6 .4 .2 n 17 28 8 4 28 28 28 28 28 28 31 28 28 28 28 28 10 No.of days in record 5 7 2 1 7 7 7 7 7 7 8 7 7 7 7 7 3 -----Data not available. Appendix Table '70 Weekly minimum,mean and maximum intragravel and surface water temperatures (C)recorded at Mainstem Susitna River at Indian River -Site 4,RM 138.6,TRM 0.2,GC S31N02W09CAB.Values were obtained from temperatures measured at six-hour intervals by a datapod temperature recorder. I Intragravel Weekly Values Surface Water Weekly Values Water Year Week Starting Calender Date Min (C) Mean (C) Max (C)n No.of days in record Min (C) Mean (C) Max (C)n No.of days in record ~o OJ 52 840923 5.6 ------7.2 9 3 5.5 ------7.0 9 3 1 841001 3.3 5.0 6.9 28 7 3.2 4.9 6.8 28 7 2 841008 2.0 3.8 5.6 28 7 1.8 3.6 5.4 27 7 3 841015 1.1 1.9 3.3 28 7 .9 1.8 3.2 28 7 4 841022 .5 1.6 3.3 28 7 .2 1.4 3.2 28 7 5 841029 .2 .4 .6 28 7 .1 .3 .5 27 7 6 841105 .2 ------.5 10 3 0.0 ------.3 10 3 -----Data not available. J J J ••I ,J ~J !I I I ••I ~I .1 3.6 Table 71 -Water temperature profiles of continuous temperature monitoring sites located in the Susitna River Basin during the 1984 open water season. "- Table 71.~ater temperature profiles of continuous temperature monitoring sites located in the Susitna River basin during the 1984 open-water field season. USGS Oi scharge at a uSGS Oi schargeb Water Temperature (GC)at Locati on Habi tat Date Sunshine Station (cfs)Gold Creek (cfs)Station (ft)At Water Surface Above Streambed Comments Susitna River Mai nstem 840928 17 ,080 7,290 O.O(lew)Datapod at river mile 30.0 6.5 6.5 recorder 18.5 250.0 6.4 6.4 750.0 6.2 6.2 1350.0 6.1 6.1 1450.0 6.2 6.2 1500.0(Rew) Ventna Ri ver Tributary 840929 16,480 7,140 O.O(lew)Oatapod (RM 28.0)20.0 6.6 6.6 recorder (TRM 4.0)200.0 6.4 6.4 500.0 6.5 6.4 600.0 6.6 6.7 700.0(Rew) Sus i tna Ri ver Mainstern 840929 16,480 7,140 O.O(lew)Datapod above the 8.0 6.3 6.3 recorder Ventna Ri ver 200~0 6.1 6.2 (RM 29.5)500.0 6.0 6.0 ~800.0 6.0 6.0 I 1150.0 6.0 6.0 0 1200.0(Rewl Oeshka Ri ver Tributary 840930 17,200 7,320 O.O(lew)Datapod (RM 40.6)20.0 8.3 8.2 recorder (TRM 3.0)70.0 8.3 8.2 130.0 8.3 8.3 140.0 8.3 8.3 150.0(Re..) Susitna River Mai nstem 840926 18,580 7,770 O.O(lew)7.2 Oatapod above the 30.0 7.2 7.1 recorder Deshka Ri ver 200.0 7.2 7.2 (RM 41.1)400.0 7.2 7.2 700.0 7.2 7.2 950.0 7.2 7.2 Kashwi tna Ri ver Tributary 841001 18,100 7,740 O.O(lew)Mercury (RM 60.9)5.0 6.3 thermometer (TRM 0.1)10.0 6.3 25.0 6.3 40.0 6.3 60.0(Rew)6.3 a USGS gaging station 15292780,provisional data. b USGS gaging station 15292000,provisional data. -!"-., "j '.\ ~. .\ m ~I j )J ~I I I J I I J ]! ]]1 --]J -]]l ]-1 )1 1 Table 71 continued. USGS Di &charge at a USGS Di scha rgeb Water Temerature (Oe)at Location Habi tat Date Sun&hine Station lcfs)Gold Creek (cfs)Station (ft)At Water Surface Above Streambed Comments Susitna River MiJinstf'm 841001 LEW 0.0 6.4 Mercury thermometer above the Kashwi tna 18,100 7,740 20.0 6.4 River 30.0 6.4 (RM 61.2)45.0 6.4 60.0 6.4 85.0 6.4 120.0 REW Susitna River Mainstem 840915 21,670 8,560 Left Bank 5.6 5.6 Side chiJnnels may be influencing above the Parks 25 feet from left bank 5.6 5.6 temeratures along the right bank. Highway Bridge 100 feet from left bank 6.0 5.8 No visible plume from the (RM 86.9)Mid'river 6.1 6.0 Tal keetna or ChuH tna Ri vers 200 feet from right bank 6.3 6.2 Datapod Recorder 100 feet from right bank 6.3 6.3 Ri ght Bank 6.3 6.3 Tal keetna Fi shwheel Mainstem 840911 22,690 9,240 Left Bank 7.6 7.6 Oatapod recorder Camp (RM 103.0)50 feet from left bank 7.3 7.3 200 feet from 1eft bank 7.3 7.2 gravel bar ------Shallow water 50 feet from right bank 7.2 7.3 )U 25 ft from RB (thermograph site)7.2 7.3 Right bank 7.3 7.4---Sus.i tnol Ri ver Mai nstem 840911 22,690 9,240 Left bank 7.6 7.6 Datapod recorder at LRX9 10 feet from La-datapod site 7.0 7.0 (RM 103.5)100 feet from 1eft bank 6.8 6.8 Left bank influenced by Hid-River 6.8 6.8 ground water seepage 100 ft from right bank 6.8 6.8 Ri ght bank 6.8 6.8 Susi tna River Mai nstem 840911 22,690 9,240 Left bank 7.8 7.9 Oatapod recorder at Curry Fishwheel 20 ft from LB (thermograph site)7.6 7.6 Camp (RM 120.7 50 ft from left bank 7.6 7.6 Debris prevented the collection 100 ft from left bank 7.5 7.5 of data at right bank Mid-river 7.5 7.5 100 ft from ri ght bank 7.6 7.5 50 ft from right bank 7.6 7.5 10 ft from right bank 7.6 7.8 a USGS gaging station 15292780,provisional data. b USGS gaging station 15292000,provisional data. Tab1e 71 continued. "{' Location Habitat Date USGS Di scharge at a Sunshine Station (cfs) USGS Di scharge b at Gold Creek (efs)Station (ft) Water Temerature ("C] At Water Surface Above Streambed Comments fJJ ~ Susitna River at LRX 29 (RM 125.9) Susitna River at LRX 53 (RM140.1) Sus i tna Ri \ter at LRX 56 (RM 142.1) Mainstem Mai nstem Mainstem 840911 840827 840916 22,690 83,380 20,470 9,240 30,180 6,280 Left bank 7.8 7.9 20 ft from L8 (datapod si te)7.9 7.9 50 ft from LB 7.9 7.8 100 ft from LB 7.6 7.6 Mid-river 7.5 7.5 100 ft from RB 7.5 7.5 50 ft from RB 7.7 7.6 10 ft from RB 8.1 8.0 Left bank 4 feet from LB 4.9 5.0 20 feet from LB 4.7 4.7 150 feet from LB 4.7 4.7 200 feet from LB 4.8 4.8 Mi d-river 4.8 4.7 200 feet from RB 4.8 4.8 100 feet from RB 4.8 4.8 10 feet from RB 5.0 5.0 Left bank Datapod 7.5 7.5 25 feet from LB 7.3 7.3 100 feet from LB 7.2 7.2 200 feet from LB 7.2 7.2 Mid-riller 7.2 7.2 200 feet from RB 7.3 7.2 100 feet from RB 7.2 7.2 25 feet from RB 7.3 7.3 Ri ght bank 7.5 7.4 Temperatures at right bank may be influenced by side channel a USGS gaging station 15292780,provisional data. b USGS 9aging station 15292000,prollisional data. J J _J ~I 1 J J J J .1 ]J .~I Jt - - 3.7 Figures 2 to 16 -Mean daily temperatures recorded at mainstem Susitna River sites during the 1984 open water season. 'aJ3 19 1 ~MIN51t:1I fIT ff1 18.5 18 17 16-U 150-14 UJ 13a:: 12 •\.:::> ~ II...<ra:::10 J V\J V N 50 UJ-a..9-t:::i ~I UJ 8 ~7 a:::6 UJ...5 <r 431: 3 2 1 0 I MAY I JUNE I JULY I AUG I SEPT 1 OCT I NOV Figure 2.Mean dai ly surface water temperature recorded at Ma i nstem Susitna River (RM 18.5)during the 1984 open water season. J I J •t )})I I ..J 1 ~J 1 I II 1 )1 1 1 1 ]]j )1 ]-)-j ) 19- 1 SioI ","NSTEIl fBlVE:Yomf't RI 'f'[ft IDAt'fPOO I 18-SH ""I N51E"f'OOVE:YOffif't RI vet I TIt:RtI)$II 17-------------- 16--0 15- 0_14- W 13-0 a::.,,. =>12-I •", t-',I,J'. 11-," ,1,",I«,"",f I I ~,.I' a::10- :~/,,:(~I,\'," W 'I,'I'( D- •, I 9-,, I V ~;\:E I I I 5L>I "8-0 , W '"I ",,'.',-, I ' (t\ I I' t-"I " 7-I• a::6- ,,-. • I , W ..• 'I , t-5-I « 3t 4- 3- 2-' 1- 0- I I I I I I I MAY JUNE JULY AUG SEPT OCT NOV Figure 3.Mean daily surface water temperature recorded at Ma i nstem Sus itna Ri ver above the Yentna Ri ver (RM 29.5)duri ng the 1984 open water season. 19-,SH MIN51t"~OCSti<A ~1vt:R 18- 17- -16- 0 IS-o-14- LLJ 13-0:: :::>12-....«~~rv0:: LLJ J2) Q..9-::::E 8~vV~LLJ....7- a:::6 LLJ.... e:( ~ 0- 1 MAY' I JUNE I JULY I AUG I SEPT I OCT I NOV Figure 4.Mean dai ly surface water temperature recorded at Mainstem Susitna River above the Deshka River (RM 41.1)during the 1984 open water season. J ]1 ]J _J ).I •J 1 .~J 1 ),.5 .'1 ]1 j j i -,)]I 1 - 1 ---J J J j j 1 I NOV I OCT I SEPT 19 1 5H "RINSlE"ABOVE KR5HMIINA RIveR 18 17 16 -15-'<.> o 14- W 13 a::12::>.....II«a::1O W Q..9 :E 8-'W.....7 a::6 W.....5-«4~ 3 2- 1-' 0 I I I I , MAY'JUNE JULY AUG ?J....... ~ Figure 5.Mean daily surface water temperature recorded at Ma i nstem Susitna River above the Kashwitna River (RM 61.2)during the 1984 open water season. 19-1 51 ""RIG liMY lIuoaE CENTER Sf'ft,j -~U1t 1 18- 17- _16- 0 15- 0-14- l1J 13Q:: ~12 I-...«II Q::10 ~l1J ~0..9 '""'-~ 00 l1J 8 I-7 Q::6 l1J l-S« ~ I MAY I JUNE I JULY I AUG I SEPT I OCT I NOV Figure 6.Mean dai 1y surface water temperature recorded at Ma i nstem Susitna River at Parks Highway Bridge Center Span-Site 4 (RM 83.9)during the 1984 open water season. 1 .J I J §I ,)),I J J J J I .~.1 ~J.!ll j )1 J -1 J ]j l -j ~ ~.....n 19-1 54 1Il1N51E1I f'8J'tE 1'ffi1<5 HI9'Ifft BRUlE 18- 17--16- 0 15-'0-14- W 13-0= ::>12-I-et 11- 0::lO-Wa..9-:E W 8- I-7- a::6-W I-5- et;:4- 3- 2- l- a- J I I I MAY JUNE JULY I AUG I SEPT l OCT l NOV Figure 7.Mean daily surface water temperature recorded at Mainstem Susitna River above the Parks Highway Bridge (RM 86.9)during the 1984 open water season. !,... 19-1 ,.rtfllPmEn Itt lRLKEl:'nft flSttfiEEL 18- 17- 16--o 15- 0_14- W 13- 0:::::>12-....<l 11- 0:lO- W Q..9- ~:EW 8- b ....7- 0:6- W....5- <l~4- 3 2 I 0 I MAY' I JUNE I JULY I AUG I SEPT I OCT I NOV Figure 8.Mean daily surface water temperature recorded at Ma i nstem Susitna River at Talkeetna Fishwheel Camp (RM 103.0)during the 1984 open water season.,I J )~I .1 J ..J I .1 ..I I -I ..~J .~ J )1 '}-i j 1 i \ , II , I-,,,,, I I.... I, .,I , I.','I , f, I I, '4 ", ~ "J'1'\,'I" ''.41",.I f 1 I I "I I ",'J~"f'\I I I,,•I,'" ,,"....'\'. :~,'\_1 ~'"'''' ,I I ""f', ..."I ,~I I • ,/'","~: ,- I ,~I,'I I, I ',I"(,, I", I IG "ftINSTE"AT LRX 9 -SITE J ~IIftlNSlElI AT LRX 9 -'SITE J , ~~., '~.':",,,: I.,',II" I "O-~:.--- 19- 18- '17- 16- o 15- o_14- W 13- et::>12- l-e:(11- et:lO- W 0.9- ::i W 8- I-7- 0::6- W I-5- e:( ~4- 3- 2- 1- - <p ~-- I MAY JUNE JULY AUG SEPT OCT NOV Figure 9.Mean daily surface and intragravel water temperatures recorded at Mainstem Susitna River at LRX9 -Site 3 (RM 103.5)during the 1984 open water season. 19 18 17 16-()150 -14 IJJ 130:: ::>12 l- II....e:( 0::10IJJ~0..9~~ 8LLIYI-7 0::6 IJJ 5-1- e:( 4-~ 3- 2- 1- 0- -I MAY 5N MIN51E"Rt'CURR'C "'J~ I JUNE I JULY I AUG I SEPT I OCT I NOV r· Figure 10.Mean daily surface water temperature recorded at Mainstem Susitna River at Curry Fishwheel Camp (RM 120.7)during the 1984 open water season. J J I J J I I j J.~..~I I , )-]1 ]])J -)J J 1 1 1 •1 1 ) 19 119 "fllNS1'EM SU5ITHft RIVER AT LRl(29 -SIT 18 ~""IN5lEl1 SUSITNft RlVEII AT un 29 -:SIT-----_...------ 17-' 16-0 15 ~14 ~13~".f -.::»12 'I •,,, t-II I <t , a::10 , 1.LJ Q.9'~~81.LJ t-7 a::6 IUJ !. t-5«4;r: 3 2 I 0 J I I I I I I I MAY JUNE JULY AUG SEPT OCT NOV Figure 11.Mean daily surface and intragravel water temperatures recorded at Mainstem Susitna River at LRX 29 (RM 125.9) during the 1984 open water season. 19 I 51 "f1Ite1Eft In LAX 53 18 17 _16 o 15 0 -14" W 130:: :J 12 ....l- e:(II a::10W ~0..9:i!L w 8 I-7 0::6 IJJ I-5- e:( 4-~ 3- 2- 1- 0- MAY JUNE JULY AUG SEPT OCT NOV Figure 12.Mean daily surface water temperature recorded at Mainstem Susitna River at LRX 53 (RM 140.1)during the 1984 open water season. I .~J J I j ]I i .J ~J ~i I :1 I -1 I 1 -1 ]1 1 ]J 1 I~ 19- 18- 17- 16--o 15- 0_14- W 13-a:::::>12- ~<l 11- a::: ·,1 W 10- ~. Q..9- ~ ~W 8- \J' ....7-' a:::6- W....5- <l ~4-· 3- 2- I - 0-' IG MINSlEn SlISITHfI RlVE~RT ~X 56 5H 1If1INSlEn SlISJTHfI RIVER AT LRX 56 ",\ " ,',. "\'"/~ ;\J .' '\ j • I , ,,1\ , ,'I ,\.', \J \ ,-,I I I I I I I', " I I \\/',v',-'\.' \) ~~ I MAY T JUNE I JULY I AUG I SEPT I OCT T NOV Figure 13.Mean daily surface and intragravel water temperatures recorded at Mainstem Susitna River at LRX 56 (RM 142.1) during the 1984 open water season. 9- 8- 7- >J ~ 19~ 18- 17- 16--U 15-o -14- W 13- 0:: :;)12- ~11- a::::10 - Wa. ~w J- a::::6- W I-5-« ~4- 3- 2- 1- 0- 54 ItflIImEIl /UlVE PCIm'Gt CftD'; MAY JUNE JULY AUG I SEPT OCT NOV Figure 14.Mean daily surface water temperature recorded at Mainstem Susitna River above Portage Creek (RM 148.9)during the 1984 open water season. J I J J I J I ,.1 I ]I )J I I " .-.l -1 .1 1 1 1 1 1 5H IMIN5'n:1I fBJYf roo CREEK -SlTt 2 IT" 5W IVt IIfmJI f'IOO'tt:roo CR E[I(-S m:J IT" 5H I1flltmE:I1 fUJyt;roo CREEK -SITt 2 Illfl 5H 1Vt1tern:1I fUJyt;roo CREEK -S ITt J IT" "It\I • -',,'.''.,..j';~~I ,I,I ,.I, •"/,.,"I •1.'\I "\I ~I r~\, -I 'I ",I~I'I "II I'I •'I~::\ , I I I '-' NOV L.\. 0il ~\ \ OCTSEPT '\ '.\ AUGJULY .t',\ , I,\ /',\,, I, , I ""~ JUNE I I'.. 19 18 17 16--o 15- 0 -14- UJ 13- 0::;:)12- t-«It- o::10- UJ ~ Q.9- :E t:y UJ 8- il t-7- 0::6- UJ t-5-«3=4- 3- 2- l- a-~ MAY Figure 15.Mean daily surface water temperature recorded at Mainstem $usitna River above Fog Creek -Sites 1-3 (RM 176.8)during the 1984 open water season. 5H 11I1 N51tlt At If1 HI Nfl tJ1 M 5lTE:rDIWf'OD ) 5H ltftltmDI flt If'lTFlNfl tJ1M :HTE (TI"£RI1lIiIl 19- 18 17 16-' '"'(.)15 0 -14-' W 13- 0:::::>12-' l-e:(11- 0::lO- W \fJ a..9- :t ~W 8- ~7- 0::6- W I-5-«~4- 3- 2- 1- O- J I MAY ,. I JUNE "• I • I ~I ,I, I " I I I I I I "I I',. I I I I •I 1 I "I,, I JULY . I..: I AUG I •I I I. I SEPT I OCT I NOV Figure 16.Mean daily surface water temperature recorded at Mainstem Susitna River at Watana Dam Site (RM 184.2)during the 1984 open water season. J I I J 1 J J !~I J ],»D I cl 'I ,- - - - 3.8 Figures 17 to 28 -Mean daily temperatures recorded at tributary sites during the 1984 open water season. OCT 19~1 SH T[Nnf'l ~I VE:R lDfl1l'flD I 18-S~![Nnf'l RIVeR (THERMOGRAPH)-_.._......------- 17- 16--()15 - 0-14 - W 13 - 0::: ::>12-.-II -«,, ,~,I..\ Q:',, lO-t ,I I I ' I IW.I r ,I I,I ' , , CL 9-I ,,. \ I I , , I ,::E .'.I I II,\' W W 8-I ",;. ~,'"I ~','.-.. 7-\, 0 Q:6- W.-5-« 3=4- 3- 2- 1- 0- I I I I MAY JUNE JULY .' I' AUG 1 ,., U\,,'....".,'"ti\,'.", "I., I SEPT \ '\ \ , >-"- NOV Figure 17.Mean daily surface water temperature recorded at the Yentna River -Site 2 (RM 28.0,TRM 4.0)during the 1984 open water season. J I I I -~_J I .R .1 -I I I -)..]J )-J I ]J 1 J J ])j j I NOV \ OCT "I I I ,,, I I,'"',",, I ,\., I SEPT .,..", I, I I, I, \, I I,.,,,,,,, ••,, I,. I AUG I',\ ,' I •,, ,'I '"" I JULY , I I ,I..f • , I , I ' , ' I I • III I I I I I , ' I ,I,I ""I I JUNE \ I I , I,,,,."v , I 5N OC~RI VI:R !THERI1OORRP1ltl '--..------:--''f- , \..I.,,' ~,\. ""I:~' SH Dt:~RIVOl [ORfFf'O[)l19- IS- 17- 16--0 15- 0-14- IJJ 13-a::::::»12- ~ lI-e:( a:::10-IJJ 9J Q..9-:eOJ IJJ 8- ~7- a:::6-IJJ ~5- e:( 4-~ 3- 2- 1- 0- 0 l I MAY Figure 18.Mean daily surface water temperature recorded at the Oeshka River (RM 40.6,TRM 3.0)during the 1984 open water season. ~KR5HHITNft RIVER 6- 5- 4- 3- 2- 1- 0- 9- 8- 7- a: IJJ ~< == 19- 18- 17- 16--U 15-o -14- IJJ 13-a: ::>12- ~lI- n:10-IJJa. :E IJJ ~ ~w [J MAY'JUNE JULY AUG SEPT OCT I NOV Figure 19.Mean daily surface water temperature recorded at the Kashwitna River (RM 60.9,TRM 0.1)during the 1984 open water season. I !],.J t I I J B I I 1 I .~J .~J I --l -J c ]]J -j ]]1 ) Figure 20.Mean daily surface water temperature recorded at the Talkeetna River -Site 3 (RM 97.2,TRM 4.0)during the 1984 open water season. 19-1 51 CHI1.1lN"RIVfl\-SIlt 5 18 17- 16- -15-U 0 14--W 13- 0::12-:::> ~11- ~0::lO- W l>J Q.9- -f:-~8-W....7- 0::6- W....5-«4-~ 3- 2- l- a- J I I I I I I I MAY JUNE JULY AUG SEPT OCT NOV Figure 21.Mean daily surface water temperature recorded at the Chulitna River -Site 5 (RM 98.6,TRM 11.0)during the 1984 open water season. ;~I J I I cl J )1 ~I .~J I ./.!c;~':I.,oi.·';;.i,'~."""~,.'""':'~'~~"'~~'".r'""'~~••,~,',;.".i-c..V' j i !I ]-J )-Cj i 1 19 ~I 54 PORtAE CRaX 18- 17- 16--U 15 - 0 -[4- W 13 -a::: =>12- t-Il-<t 0:::lO-Wa..9--A I I ,", ,- ~~ W 8- \)J t-7-(J\ 0:::6- W t-5- <t ~4- 3- 2- "I 1- 0- I I MAY JUNE JULY AUG SEPT OCT NOV Figure 22.Mean daily surface water temperature recorded at Portage Creek (RM 148.8,TRM 0.1)during the 1984 open water season. ~-~..~.~~-- 19- 18- 17- 16--o 15- 0 -14- W 13- 0:: :J 12- f-«11- 0::lO-W Q.9- ~:E W 8- ~f-7- 0::6- W f-5-«~4- 3- 2- 1- 0- I I MAY 51 f1I8 [X;[I( / I JUNE I JULY I AUG A I SEPT I OCT I NOV Figure 23.Mean daily surface water temperature recorded at Fog Creek (RM 176.7~TRM 0.1)during the 1984 open water season. 1 J .].~_"._..J I )J ~.1 I I I ;Jli ,,'f .•_._ .1 j ]]]J J ]j 1 1 j 19~1 5H TStmfl CREEK 18- 17- 16--U 15 - 0-14- W 13- 0:: ::>12-.-11-<t a::lO-W >U a.9- \)J ~ -J w 8-.-7- a::6- W J.-5- <t ~4- 3- 2- 1- 0-t I MAY JUNE JULY AUG SEPT OCT NOV Figure 24.Mean daily surface water temperature recorded at Tsusena Creek (RM 181.8,TRM 0.1)during the 1984 open water season. 19-1 5t Dtf'OOt't lXEl 18- 17- IS--o 15- 0 -14- W 13- D:::J 12- I-<t 11- ffi 10-1 A.fV\JJ\J'~a..9- 2:0()W 8- I-7- 0::S- W I-5- <t:t 4- 3- 2- l- a-,i r Iii( MAY JUNE JULY AUG SEPT OCT NOV Figure 25.Mean daily surface water temperature recorded at Deadhorse Creek (RM 120.9,TRM 1.0)during the 1984 open water season. J J ).~)_J !J )I I .I )'J ,)~..J !I ·.J J ]--J ]j 1 1 j ]1 191Iii rDU'm1 rT ..u.l f'l..L11E - 5 m:I 18 IGrDunM rT..u.l C~-'In:1-------------17 16--0 15- ~14 W 13 0::""::::>12 ' II It-I • <t II ".,I \ 0::1 I 10 ,II W 'II,. 0..9 , 9.J 2:I.', \)j W 8 , I -0 t-I 7 ,,, 0::I 6 I W {,"t-5 ',... I <t , 4 , ~,J\-' 3 ",~... I, 2 ... I 0-: J I I I I I I MAY JUNE JULY AUG SEPT OCT I NOV Figure 26.Mean daily intragravel water temperatures recorded at Fourth of July Creek and Plume -Site 1 (RM 131.1,TRM 0.0)during the 1984 open water season. 19~1 IQ INO[~IUvtR -!1m:3 18-:i4 11IJ[f'N RIveR -!lltt 3---------_..._- 17- 16-'-<..)15 - 0......14 - I.1J 13- 0:: :::).12- t-Il-<l 0::10I.1J :D a..9 'f::-:E I.1J 80t-7-1 l, 0::6- I.1J t-5- <l ~4- 3 2 1- 0 , i I i i I MAY JUNE JULY AUG SEPT OCT NOV Fi gure 27.Mean daily surface and i ntragrave 1 water temperatures recorded at Indian River -Site 3 (RM 138.6,TRM 0.2)during the 1984 open water season. I t J I J I ~-~1 I B I I l 1 )1 j 1 j J ]j -]1 -j --1 1 ]i 1 1 ~ ~-- '9i IG INDIAN RI~-SIIE 1 18 :It INDIAN 1110 -'lIE 1..~-----------17-, 16-'-U 15 0-14 W 13-' Q: ~12- l-II-« 0::10- l.LIa..9- ~ l.LI 8- I-7- 0::6- W....5-« :t 4- 3- 2- 1- 0- MAY JUNE JULY AUG I SEPT I OCT I NOV Figure 28.Mean daily surface and intragravel water temperatures recorded at Indian River -Site 4 (RM 138.6,TRM 0.2)during the 1984 open water season. 3.9 Figures 29 to 45 -Site maps depicting locations of study areas during the 1984 open water season. - - - - - - J j l ]-]--])1 1 •1 j »1 )) \.~..~ o 1500 I I FEET (Approlt.Scale) SUSITNA RIVER AT RM 18.5 GD RYAN TEMPERATURE RECORDER _--------:r ~ EDRM 19 R/V£Rsus/rNA ~ "'f::... W Figure 29.Locati on of the temperature monitori ng stati on at Mai nstem Susitna River at RM 18.5,GC SlGN07W15DCD. .- ..' •it'.~.{'!"~'......,.'.',;, (NOT TO SCALE) YENTNA RIVE R (!)RYAN TEMPERATURE RECORDER ~ .. YEN7NA RIVER .,l"_..~··~.....-•••': ...~...~ <;../. :,--......-/"'). ~ '{:: 'i:::. Figure 30.Location of the temperature monitoring station at the Yentna River,RM 28.0,TRM 4.0,GC S18N07W28ABC. I 1 I 1 1 I )I J i ~J J J 1 )J )II J )]J 1 1 -j )1 )-1 -) ~ Q)RYAN TEMPERATURE RECORDER [Q]DATAPOD TEMPERATURE RECORDER o 1500 I I FEET (Approx.Scale) SUSITNA RIVER ABOVE THE YENTNA RIVER RIVER ~':l'~'\~"'':' O ~'l"'l .J "J:-'". ~IVf:~ EDRM 29-----~., ..-J....... .:-;:"::.i:';1l.:"":~'. '(f: NfNA .~~. '..;1 -f,}' ." .,_i'''' ,";:. ~:..r.,;.:l~,,-"l:~:';;l' ?->-t: 'tT Fi gure 31.Locati on of the temperature monitori ng stati on at Mai nstem Susitna River above the Yentna River,RM 29.5, GC S17N06W07CAD. DESHKA RIVER <I:l RYAN TEMPERATURE RECORDER {QJ DATAPOD TEMPERATURE RECORDER o 1000 I I (Approx.Scale)",'., .. - - - - Figure 32.Location of the temperature monitoring station at the Deshka River,RM 40.6,TRM 3.0,GC S21N06W13AAC. - (!)RYAN TEMPERATURE RECORDER SUSITNA RIVER ABOVE THE DESHKA RIVER FEET (Approll..Scale) at Mainstem RM 41.1, station River, temperature moni tori ng above the Deshka 1000 I o I Location of the Susitna River GC S19N06W26SBC. Figure 33. ..... I - - - - KASHWITNA RIVER a SUSITNA RIVER ABOVE THE KASHWITNA RIVER G)RYAN TEMPERATURE RECORDER A SUSITNA RIVER ABOVE KASHWITNA RIVER B KASHWITNA RIVER o 1000 I I FEET (Approx.Scale) ~ \\ !im!fl ~-" -, ", ",, ~ I,0Im I, 'A't j, :: '.- e. " ," '. .... ". Figure 34.Locations of the temperature monitoring stations at the Kashwitna River',RM 60.9,TRM 0.1,GC S21N06W13AAC;and Mainstem Susitna River above the Kashwitna River,RM 61.2, GC S31N05W13ABA. --j -l j 1 J -)-]]]]])1 I ~/ -JE-~\ 1~fA uS \ S~ $RM 84 ~ .,........~to ••..t/'., ~ 5 U 51 T NA RIVER AT PARKS HIGHWAY BRIDGE ®RYAN TEMPERATURE RECORDER A CENTER SPAN·SITE 4 o 1000 I I FEET (Approx.SCQI,) ~ ~ '-G Figure 35.Location of the temperature monitoring station at Mainstem Susitna River at Parks Highway Bridge,RM 83.9, GCS24N05W15BAD. ""'" - - - I~OO I FEET (Approlt.Scale) o I ------------" ""I \I'f !......-DEWATEREDIrCHANNEL \\ ,'\. ""'"...............--..:::......-"""\\ SUSITNA RIVER ABOVE THE PARKS HIGHWAY BRIDGE @ RYAN TEMPERATURE RECORDER ~ ~ ~ ~ "-Q:-- ~ ~ Qk....~.: "-'; <i)";to ~ <i)~ Figure 36.Locati on of the temperature monitori ng station at Mai nstem Susitna River above the Parks Highway bridge,RM 86.9, GC S26N04W16CBA. 1 )1 ]J 1 J ]}]} Ir ""=: :i''. ~I "1, :.1 .'.:.: "...:, .If. '.';''.;.:.-;;,.,,,.... ':'~::;;:;:/':'~::";~,..,.~'"w;sr-hA ..•,~..•~~..Q:.•.••:.;:..~.~:•..~......-:~.\·;b·"·..r·;:iJ·;';ti·.....t tT):.:~:::::.~./.+'.~'-<":"';':';';"""'."'.---- ~:'.o/:i/···"..·.,.....Talkeetna River TRM"';~~?' a 1000 I I FEET (Approx.Scale) TALKEETNA RIVER CD RYAN TEMPERATURE RECORDER A SITE 3 ~- Figure 37.Location of the temperature monitoring station at the Talkeetna River,RM 97.2,TRM Y.O,GC S21N06W13AAC. CHULITN A RIVER @ RYAN TEMPERATURE RECORDER A SITE 5 :~fl·CJ TRM II 2000 I FEET (Approll.Scale) a I .'.. Figure 38.Location of the temperature monitoring station at the Chulitna River -Site 5,RM 98.6,TRM 11.0,GC S27N05W05ABC. o c:{oa::: ....J «a::: SUSITNA RIVER AT LRX 9 a TALKEETNA FISHWHEEL CD RYAN TEMPERATURE RECORDER B MAINSTEM AT TALKEETNA FISHWHEEL o 500 1 I FEET (ApprOll,Scole> [Q]DATAPon TEMPERATURE RECORDER A MAINSTEM AT LRX -Site 3 I Q:: It,, ~..... ~~,', 'I, ~ LRX 9 " . "I.- P" ~.....'~~"1 '4 ",0 :-~-::::'o:::t .. ":0 <:"," \-'0.-:.V)!:.~ "V)"-";; \ EBRM 103 - I"'" I ,.,.. ..... "'.. .- Fi gure 39.Locations of the temperature monitoring stations at Mainstem Susitna River at Talkeetna Fishwheel Camp,RM 103.0, GC S27N05W26DDD;and Mainstem Susitna River at LRX 9,RM 103.5,GC S27N05W25BBC • •'.'"'.•'-.:<:.~.:'.•...•.•' ~(il-t t?,j / If N.A SUS 12161 ) SUSITNA RIVER AT CURRY FISHWHEEL CAMP IT'RYAN TEMPERATURE \V RECORDER a !500 I I FEET (Appro ••Seal.) Figure 40.Location of the temperature monitoring station at Mainstem Susitna River at Curry Fishwheel Camp,RM 120.7, GC S27N04W10CBA. J I ),J .J 1 1 J J I ~!J J 1 ,J - .... - T Figure 41. ED RM 121 DEADHORSE CREEK 'r RYAN TEMPERATURE RECORDER o 500 FEET (Approx.Scale) Location of the temperature monitoring station at Deadhorse Creek,RM 120.9,TRM \.0"GC S29N04W14BCB. RIVER ··"'···'~..c..H!S.!P 4~ ~T *\*.i '»'1 .~l-'··r'>i'l.'b ------S l/SIrAt4 •;;-...·,'10 "MAIN STEM AT LRX 29 -SITE 3 ..-...... [Q]DATAPOD TEMPERATURE RECORDER ~ o 2000 I I FEET t ApprOll.Seol.) Figure 42.Location of the temperature monitoring station at Mainstem Susitna River at LRX 29,RM 125.9,GC S30N05W19DAB. I I J I ,]J I ~I I J J I I 1 ,I II j -j j J J ])1 'J '.J ]J 1 J 1 i .UJ ~ -J FOURTH OF JULY CREEK UD DATAPOD TEMPERATURE "ECORDE" A SITE .1 o 250 I I FEET (Approll.Scal.) '-----SUSI TNA RIVER - RM 131.1 ED Figure 43.Location of the temperature monitoring station at Fourth of July Creek -Site 1,RM 131.1,TRM 0.0,GC S30N03W03DAC. ~ (£ INOI AN RIVER WJ DATAPOD TEMPERATURE RECORDER . A Site 3 B Site 4 o 500 I I I FEET (Approll.Scale) Figure 44.Location of the temperature monitoring station at Indian River -Sites 3 and 4,RM 138.6,TRM 0.2,GC S31N02W09CAB. ~j J ,J I I I I J I 1 a 1 .~I J .~ 1 -J J )1 1 J 1 1 ~!:;,-~-'~...."~::,\:••:....=.'.;'.~~.:."Lt"~.~!:;··I·:::"::~·.:~;·:::-·';';'':-::·;'·h\~.".""~.·j1ti\\ SUSITNA RIVER AT LRX 53 GD RYAN TEMPERATURE RECORDER ~ lJ1 -D ~,.r .. EBRM 140 _-'-_C.O"";.:-;"!~I·:"':;·~~-.;.,rJo.•u::.1::_r..~~'7.:!. o 500,I FEET (ApproJ.,Scale) 10 It) Xa: ..J --,----- ..;.t..•.. SUSlrNA ~:,', ;, :to..',' RIVER _______ v.:J~~";;il~__ .."..·":'~""'·:••iI ;_~ .'';'~·i.7i""':;,,~~.S'._:_>~_.~I... I ."':'::,. ,;.....\'..)":,,,,~'-...... Figure 45,Location of the temperature monitoring station at LRX 53, RM 140.1,GC S31N11W10AAC. Y-' ~o :;';;'f!!"i,;;·.i:·'i-·ij~'·'J~!.,..!.!,.:b:~." ....:ii:.~.,l •...-~~ SUSITNA RIVER LRX 56 o DATAPOD TEMPERATURE RECORDER A MAINSTEM AT LRX 56 -Site I o 500II FEET (Approll.Scal.) Figure 46.Location of the temperature monitoring station at Mainstem Susitna River at LRX 56,RM 142.1,GC S31NIIW36BCD. :I I ~I I I J ,J I I .J I I J -.1 -i •l 1 J 1 ]J J J 1 /.-7 f{....7 ,,~ ~, PORTAGE CREEK a SUSITNA RIVER ABOVE PORTAGE CREEK ~DATAPOD TEMPERATURE/ STAGE RECORDER A PORTAGE CREEK®RYAN TEMPERATURE RECORDER B MAINSTEM ABOVE PORTAGE CREEK o 250 I I FEET (Approlt.Scale) ______S lJ S I f 1'1 Jl ~';'.'..!!~!.J ..aJ.i.·.~· , ~ ~ Figure 47.Locations of the temperature monitoring stations at Portage Creek,RM 148.8,TRM 0.2,GC S32N10W25AOC;and Mainstem Susitna River above Portage Creek,RM 148.9,GC S32N10W16ACB. FEET (Approx.Seol.) FOG CREEK a SUSITNA RIVER ABOVE FOG CREEK - - - 1000 I o, <i>RYAN TEMPERATURE RECORDER A FOG CREEK B MAIN STEM ABOVE FOG CREEK rID DATA POD TEMPERATURE RECORDER B MAIN STEM ABOVE FOG CREEK Figure 48.Locations of the temperature monitoring stations at Fog Creek,RM 176.7,TRM 0.1,GC S31N06WI5DBB;and Mainstem Susitna River above Fog Creek,RM 176.8,GC S31N06W15BAC. '1 ..,}i I ~J 1 ]J .J 1 ·1 i .J "j 1; TSUSENA CREEK If\RYAN TEMPERATURE \..!.J RECORDER .t·'.:I!.,.~.·.!r.~;\:",,""\r:/.I.~.J.{."&.o!'...tt .....•.•~~~~•.,,:-... ED RM 182 .•_.....o;..::~;J;..t;....·-,i'i,":."'·v..._....• o 500 I , FEET (ApprOll.Scall) "0 t."h't''".-I~.·~~wl'''''~..c. ).J {j' lJJ ~-SUSlrNA RIVER -__ ...~~f..(.:-}1r;»1'!X .~,;T":-..;:t:·~/A\':)!':'_ifillJi5ij'.(-:••t '~••'.'~'bi;a:'I"I"'f2j,;i""yf ~.;J.:~'••",u!::~n·.:,.."..... :;.1:..-.....u: ~".~~.~-c.1~~e;,\i~,);*lfr·.if'" Figure 49.Location of the temperature monitoring station at Tsusena (reek,RM 181.8,TRM 0.1,GC S32N06W36ADB. ~ t) 4-t::. Figure 50. ·:~...:·"t-b·.·"." SUSITNA RIVER AT WATANA DAM SITE G)RYAN TEMPERATURE RECORDER [QI DATAPOD TEMPERATURE RECORDER ~1.LOCATION OF PROPOSED DAM o 1000 I , FEET (Approll.Scale) Location of the temperature monitoring station at Mainstem Susitna River at Watana Dam Site,RM 184.2,GC S32N05W33BDB. J .~I II !I •I I 1 l I I •J J - - - I' r LITERATURE CITED Alaska Department of Fish and Game.1984.Susitna Hydro aquatic studies (May 1983 -June 1984)procedures manual (l of 2).Alaska Department of Fish and Game Susitna Hydro Aquatic Studies. Anchorage,Alaska. Voos K.<and P.Meyer.1984.Personal communication.Meeting May 16, 1984.Arctic Environmental Information and Data Center. Anchorage,Alaska. 265