HomeMy WebLinkAboutAPA plan of study Vol 3 supplemental info 1979'-
VOLUME III -SUPPLEM<-ENTAL
INFORMATION
"I :
HYDR'OELECTRIC
PRO,JECT
SEPTEMEBER 1979
I--IAR.ZA ENGINEERING COMPANY
ALASKA POWER AUTHORITY
ANCHORAGE,ALASKA
PLIAN OF STUDY
FOR
PROJECT FEASIBILITY AND
-FERC LICENSE APPLICATION
This volume presents experience resumes of personnel involved
in the studies.This volume is divided in three parts
as follows:
-A:
VOLUME III
SUPPLEMENTAL INFORMATION
INTRODUCTIon
Harza-CH2M HILL (Multi-disciplined Planning)
FLr+1
(10 L\oo-i-
v,~>
B:Woodward-Clyde Consultants (Seismic Geology and
Seismology)
C:Fluor Power Services (Alternative Thermal Generation)
ARLIS
Alaska Resources
Library &Information Services
Anchorage,Alaska
RESUMES
Following is a list of proposed personnel and their
positions for the study.Resumes are included in alphabetical
order.
Position Name
Corporate Sponsor R.D.Harza
Project Manager D.L.Glasscock
Review and Advisory Board
Planning and Engineering K.E.Sorensen
Environmental B.J.Gallagher
Public Information R.S.Ivey (CH2M HILL)
Project Engineer R.L.Meagher
Senior Technical Staff
Hydroelectric Engineering A.E.Allen
Hydrology R.W.Revell
Arctic Engineering H.K.Pratt
Geology C.L.Willis
Soils and Foundations J.A.Scoville
Concrete Dams R.P.Wengler
-Construction R.F.Koken,
Planning and FERC Licensing
-Team Leader L.D.Nichol
Hydroelectric Projects K.R.Leonardson
Hydroelectric Design E.T.Moore
Resident Planning Engineer R.A.Zylman
Project and Basin Planning R.C.Hundley
L.B.Buetikofer
R.A.Westmore-D.Kleven (CH2M HILL)
Arch Dam Design w.Y.J.Shieh
Design
Transmission
System Planning
Mechanical Equipment
Electrical Equipment
Operation Studies
Geology
Engineering Geology
Field Geologists
R.S.Burkhart
J.T.Nikolas
L.L.Wang
D.J.Castellani
J. J.Keller
P.J.Donalek
T.Small (CH2M HILL)
R.J.Mesa
R.C.Acker
J.Q.Sims
R.A.Paige
P.A.Dickson
A.H.Stukey
Hydrology B-H.Wang
Streamflow F.Damron (CH2M HILL)
Sediment K.Jawed
Water Quality B.K.Lee
Soils Foundations and Construction F.D-L.Young
Material s R.G.Oechsel
Soil Mechanics V.Singh
Rock Mechanics E.M.Cikanek
Concrete Structures
Construction Materials
Construction Engineering
Construction Procedures
G.R.Mass
P.S.Stoffey
B.A.Anthony
K.S.Platou
Construction Schedules
Cost Estimates
Economics and Finance
Team Leader
Power Market
Alternative Sources
Economic Analysis
Financial and Institutional
Analysis
Environmental Sciences
Team Leader
Aquatic Ecology
Fisheries
Water Quality
Permits
Assessment Methodology
Terrestrial Ecology
Wildlife
Vegetation
Forestry
Transmission Corridors
Human Ecology
Socioeconomics
History/Archaeology
R.L.Watt
R.D.Hilliard
G.V.Volland
J.West
A.C.Vircol
E.F.Carter
D.Sulkowski
J.H.Thrall
J.P.Robinson
J.P.Robinson
G.I.Bresnick
J.H.Thrall
J.H.Thrall
E.F.Dudley
E.F.Dudley
J.J.Kuruc
J.J.Kuruc
E.F.Dudley
W.L.Partridge
S.Brody (CH2M HILL)
Outside Consultant
-
-
Cultural Resources
Resource Inventory
Land Use
Remote Sensing
Recreation
Data Management
Resident Engineer
Public Information Specialist
Subcontract Administration
w.L.Partridge
R.G.Anderson
H.E.Schoeller
Alaskan Resident
W.R.Larson
ENGINEERING COMPANY
RICHARD C.ACKER
Associate and Head,
Geological Division
Master of Science in Geology
Brown University,1950
Bachelor of Arts in Geology
Williams College,1947
Engl"lsh,Working knowledge of French
and Spanish
languages:
Professional Registrations:
Professionill Geologist No.1833,California
Engineering Geologist No.576,California
Degrees:
Professional Societies:
Association of Engineering Geologists
Geological Society of America
Harza Engineering Company since 1962.
Associate,1975.
Geologicill Division,Head,1973 to date;Geotechnical Division:Head,Geology Department,1967-73;Indus Basin
Division:Geologist,1966-67;Pr"lIlcipal Geologist and Chief,Geology and Materials Branch,West Pakistan,1962·66.
Experience Highlights:
Responsible for the work of the Geology D'lvision staffed with approximately twelve engineering geologists.
Specific responsibilities include planning,schedullllg,direction and review of geologic field and office studies
ilnd reports for variety of civil works prOJects.This work ranges in scope from regional appraisal studies to
deladed site studies with emphaSIS on hydro projects,underground facilities,and related ground-water problems.
Some typical projects undertaken by the division 'lIlciude-
Reza Shah Kabir Dam,Iran -feasibility and design investigation and studies of 650·foot high arch dam.
Nader Shah Dam,Iran -deSign investigations for 480-foot high rockfdl dam.
St.Lawrence Basin Appraisal Studies -18 damsites.
Blue Mountalll Water Supply Project,Jamaica -appraisal and feasibility studies,diversion dams and tunnels.
Chicago North Side Rock Tunnel -.feasibility investigations,200 mile rock tunnel complex.
Patia River Basin,Colomb'la -appraisal of 28 damsites,prefeaslbility investigation of 5 darnsites,and feasibility
study of 660-foot high rockfill darn.
Gavin Fly Ash Darn and Reservoir -site selection and design studies for waste retention facility.
Strontia Springs Darn,Colo.-feasibility and deSign studies for 30G-foot high arch darn.
Uribante-Caparo Project,Venezuela -feasibility s1Udies of four darn and tunnel complex.
RICHARD C.ACKER
Responsibilities as Principal Geologist and Chief,Geology and Materials Branch in Lahore,West
Pakistan included:furnishing guidance,technical assistance and training to WAPDA group of 22
geologists performing geologic mapping,subsurface and materials investigations,and preparing
geologic reports for feasibility and design of reservoir projects;reviewed geologic investigations and
reports by WAPDA and various project consultants on Independent Development Works.Carried out
surveillance and review of geological investigations by project consultants as I iaison for Harza,Chicago,
on Indus Basin projects including Mangla Dam and Tarbela Dam.
1956 to 1962:
U.S.Army Corps of Engineers;New York.N.Y.
District Geologist and assistant to Chief,Paving,Foundations and Materials Branch.Responsibilities
in~:All geologic work relative to siting,foundation and materials investigations,design,
construction and maintenance of structures,paving and water supply for nine military airfields and a
widespread rader/communications network.
1950 to 1956:
U.S.Army Corps of Engineers,Baltimore,Maryland.
District Geologist.Responsibilties Included'All geologic work in planning,design and construction
of dams and flood control structures;and in foundation design and construction of various military
installations;investigations for mineral resource evaluation in inundation areas.
1947 to 1950;
Brown University;Providence,Rhode Island.
Graduate Teaching Assistant,Geology Department.
1948:
R.T.Vanderbilt,Inc.;Balmat,New York.
Geological Assistant to Mine Superintendent.Underground tremolite mining.
1945 to 1946:
U.S.Army Corps of Engineers,Ft.BelVOir,Virgmia.
1944 to 1945:
U.S.Bureau of Mines;Starlake,New York.
Field Foreman of survey team and Geophysical Field Assistant for strategic minerals investigation.
Technical Papers and Articles:
"Rock MechaniCS Studies for Mossyrock Arch Dam"ASCE.Power Journal,January,1971 co-author
with D.E.Kleiner.
"Foundation and Abutment Treatment for Rockfill Dams"ASCE Journal Soil Mechanics and
Foundat"lons DiVision,October 1972 co-author with Jack C.Jones.
"Geologic Aspects of the Chicagoland Flood Control and Pollution Abatement Program"-paper
presented at '972 North American Rapid Excavation and Tunneling Conference.Co-author with R.S.LaRusso.
2/76
ENGINEERING COMPANY
ARTHUR E.ALLEN
Vice-President and
Chief Power Development Engineer
Degrees:Master of SCience in Civil Engineering
Carnegie InSlltuW of Technology,1939
Bachelor of Science in Civil Engineering
Carnegie I nsti lu Ie of Technology,now
Carnegie-Mellon University,1938
Professional Engineer -Ariwna,IllinoIs,New Jersey,
Pennsylvania,Virginia and Washington
Professional Societies:
American Society of Civil Engineers (Fellow)
Advisory panel on research in pumped-storage,September,1968
Power Division Committee on Hydro Power Project Planning and Design,1969-71
Power Division Research Committee,1974-77
Harza Engineering Company since 1960.
Vice-Presiden I,1971;Associate,1964.
Chief Power Development EnrJineer,1977 10 date;Chief Hydroelectric Engineer,1967-77;Civil D·lvision.
Assistant Division Hpad,1966-67.Planning Division:AssistJnt DiviSion Head,1965-66;Department Head,
1964·65;Section Head,1962-64,Cngineer,1960-62.
Experience Highlights:
Project ManClger for 380-MW Kinzua (Seneca)HydroelectriC Project,Pennsylvania,through planning,design,
construction and start-up operations,including preparation of Original Cosl Statement,F.P.C.Form 6.
Project Director for the Gavlfl 15-mile Coal Conveyor Civil Works,a mine water supply dorn,and the Gavin
and Muskingum Fly Ash Dams,OhiO,through planning,design and engineering services during constructlCJn,
Studies.Conventional and pumped-storage hydroelectric power at exisllng Federal darns In the Knnnwha River basin,
West Virginia;underground pumped-storage and surface sites In northern illinOIS for Commonwealth Edison
Company clnd in Wisconsin for the Wlsconsln·Upper Michigan System,potential development of Clarion River
312-MW hydroelectriC bcility for Pennsylvania ElectriC Company;500-MW Montezuma project for Arizona Power
Authority;240-MW Brookville project for PubliC Service Indiana,525-MW Raystown site for Pennsylvania Electric
Company;2000-MW Merrimac site for Wisconsifl Power &Light Company.
AnalYSIS of 1700-MW Stony Creek projecl for Pennsylvania Power &Llghl Company and Metropolitan Edison
Company.Assistance In preparation of License Application to Federal Power CommlSSloll
AnalYSIS of 1,OOO-MW Mount HOlJe Project,underground pumped-storage and compressed-air storage,for Jersey
Central Power &Light Co.Assistance In preparing license application to Federal Power CommisSion.
Evaluated alternate tunnel and surface roules for lO-miles of coal conveyor for American Electric Power
System.
ARTHUR E.ALLEN
Review and advice on layouts for 500-MW Havasu project.Arizona Power Authority,Arizona.
Supervised studies of vibratory-induced stresses on Smith Mountain Dam and penstocks for American
Electric Power System and for application to FPC for addition of a reversible pumping-generating
unit.
Expert witness on hydroelectric costs for Pend Oreille County Public Utility District in suit with
City of Seattle.
Compiled data and computer studies for Niagara project power operation and regulation of Lake
Ontario and testified on various aspects of Great Lakes Diversion case before Special Master,U.S.
Supreme Court.
Prepared FPC license applications for existing Deep Creek,Raystown and Warrior Ridge hydroelectric
projects of Pennsylvania Electric Company.
Expert witness for Beaunit Fibers,Inc.for river regulation problems in Alabama.
1958 to 1960:
Non-engineering work.
1940 to 1958:
Aluminum Company of America.
Assistant Chief Power Engineer.Hydroelectric planning,design,and operation related to industrial power use.
Experience Highlights:
Studies,preliminary designs and hydraulic design for numerous hydroelectric dams for aluminum smelti ng faci I ities.
Prepared license applications to FPC for power facilities,testified in FPC hearings.
Assisted company officials In negotiations of power contracts with other utility systems.
1941 to 1945:
U.S.Army,Chemical Warfare Service.Railroad operation and track construction.
1939 to 1940:
U.S.Army Corps of Engineers,Pittsburgh District Junior Engineer.Hydroelectric computations
and model studies for deSign of spillways for dams and flood channel improvements.
As student,summer experience With Hydraul ic Research Laboratory,Carnegie I nstitute of
Technology,Madden Dam sluices and Tionesta Dam Spillway.
5/78
ENGINEERING COMPANY
Professional Societies:
ROGER G.ANDERSON
Acting Head,Earth Sciences Department
Degrees:
Languages:
Master of Science In Forest Ecology/Remote Sensing
University of IllinOIS,'979
Bachelor of SCience i'l Forestry/Outdoor Recreation
University of Michigan,1971
English and French
-
American Society of Photogrammetry
Society of American Foresters
Harza Engineering Company since 1972.
Environmental Sciences Division:Acting Head,Earth Sciences Department,'979 to date,Recreation Planner,
1972-7S.
Experience Highlights:
Supervised analysis of the surface characteristics of the S9,OOO-sq km Caronl River Basin above Guri Dam,Veneluela,
using remote sensing techniques for reference in developing computer models for streamflow forecasting.
Proiect Manager for engineering and environmental studies for a water supply intake structure and pipel ine for an
electric utility company in Illinois.
Assistant Project Manager,siting studies for nuclear and fossil~fueled electric generation In northern Indiana.Responsible
for an assessment of the effects of management deCisions concerning reservOir surface levels on recreation facilit'les
and visitor use and for a visual resource IIlventory and impact analyses.Directed the activities of aquatic and terrestrial
ecologists for related environmental assessments.
Provided an appraisal of potential impacts of reservoir development on tropical forest resources for the Upper
Mazaruni Hydroelectric Project in Guyana,South America.
Project Manager,Great Lakes-S!.Lawrence Seaway Navigation Season Extension Demonstration Program.Responsibilities
included preparation of technical reports,including the fiscal year of 1976 Environmental Impact Statement.
Developed alternative conceptual plans and preliminary design for water~based recreational development at the Bath
County Pumped-Storage Project,Virginia.
Participated in all phases of recreation planning for the LaSalle County,1lllIlOis,Nuclear Station Cooling Lake,from
initial assessment of recreation potential through detailed site planning and design.
Provided alternative concepts for reclamation of strip~mined lands for recreational development at the Braidwood
Nuclear Generating Station Cooling Lake.
ROGER G.ANDERSON
Developed environmental assessments and impact analyses for several water resources development projects,including
the Garrison Diversion Unit in North Dakota (including interim projec1 management);flood control measures in
Webster City,Iowa;and the Stony Creek Pumped-Storage Project in Pennsylvania.
1971 to 1972:
City of Geneva,Illinois.
Assistant to CiW Forester.Responsibilities included all phases of municipal forestry programs.
2/79
-
t--u-U'"",,,iIt-,;--,ENGINEERING COMPANY
BRIAN A.ANTHONY
Associate and Head,
Construction Management Division
Degree:
languages:
Bachelor of Civil Engineering
University of Sydney,Austral ia,1957
Continuing Education.
Graduate courses in Construction Management and
Business Administration at University of Alberta
and University of British Columbia
English,some Spanish and French
-
-
-
Professional Engineer -Province of British Columbia,Canada and
Province of Saskatchewan,Canada
Professional Societies:
Arnerican Society of Civil Engineers
Canadian Society of Civrl Engineers
Engineering Institute of Canada
Institute of Engineers of Australia
Harza Engineering Company since 1971:
Associate,1976.
Head,Construction Management Division,1978 to date;Executive Manager,Harza Engineering Company International,
1973·77;Resident Engineer,1971-77.
Experience Highlights:
Head of Construction Management Division in Chicago office.Responsible for management of all construction
engineeri ng,construction scheduling,cons tructlon inspection,contracts ad m in ist ration,specifications and estimat"lrlg,
technical procurement,field liaison,and resident engineers.
Resident Engineer on the construction of the Reza Shah Kablr Project in Iran.Responsible for the prOject management
of seven major contracts consisting of a 200 meter high concrete arch dam,a 1000-MW powerhouse and a switchyard.
Resident Manager for Iran concerned with new business development other than on the Karun and Marun PrOjects,
Chief Resident Engineer tor all Harza Engineering Company International (HARZINTl construction work In Iran.
Projects consisted of the 200-meter high concrete arch Reza Shah Kabir Dam,the 170-meter high rockfill Nader Shah
dam,and the 22-meter high Gotvand Diversion Dam,the 42,000-hectare Gotvand and the 15,000-hectare Behbehan
Irrigation Projects;and 884.9 kilometers of a 400-kV transmission line and four 400-kV substations.
BRIAN A.ANTHONY
1964 to 1971:
Montreal Engineering Company Limited,Montreal.Quebec,Canada.
Resident Engineer.Assigned to the TRIUMF 500-Me V Cyclotron at the University of British Columbia.
Responsible for the civil construction,supervision,contract administration and client relations for the construction
of the Cyclotron facility.
Resident Engineer and General Construction Superintendent.Assigned to the Karachi Nuclear Power Station for
the Pakistan Atomic Energy Commission,Responsible for the civil construction,supervision,contract administration
and client relations on a "turnkey"construction contract for the 137·MW Candu type reactor.
Assistant Resident Engineer,Assigned to the Charuroqui Power Development,Bolivia.Supervised the construction
of headworks,pressure tunnel,penstock and powerhouse,including installation of turbines and generators for
the 13·MW units.
Resident Engineer.Site investigations for Kraft Pulp Mill,Nova Scotia,Canada.
1961 to 1964:
Sverdrup and Parcel International,Inc.,St.Louis,Missouri.
Powerhouse Engineer.Yanhee Project,Thailand.Responsible for civil construction supervision of powerhouse
and associate concrete work on the $100 million,1-1/2 million cubic yard concrete arch dam and power plant.
1960 to 1961:
Strong,Lamb &Nelson,Regina,Saskatchewan,Canada.
Design and Resident Engineer.Assigned to oil pumping terminals,roadworks and water supply and treatment
facilities in southeast Saskatchewan.
1959 to 1960:
Commonweal th Department of Works,Sydney,Austral ia.
Structural Design Engineer.Assigned to reinforced concrete structures for military installation.
1958 to 1959:
Metropolitan Water Sewerage and Drainage Board,Sydney,Australia.
Construction Engineer.Assigned to the 1-'/2 m ill ion cubic yard Warragamba Dam,Austral ia.
1956 to 1957:
Junior Field Engineer.Assigned to the construction of two 300,000 cubic yard concrete gravity dams,
Keepil and Tinarro Falls Dams for State Water Conservation and Irrigation Commissions.
8/78
ENGINEERING COMPANY
GERALD I.BRESNICK
Head,Aquatic Ecology Section
-Degrees:
Languages:
Doctor of Philosophy in Biology
Tulane University,1975
Bachelor of Arts in Biology
State University of New York at Buffalo,1971
English and working knowledge of German
and Spanish
Professional Societies:
American Association for the Advancement of Science
American Fisheries Society
American Society of Ichthyologists and Herpetologists
American Society of Limnology and Oceanography
American Society of Natural ists
Harza Engineering Company since 1976.
Environmental Sciences Division.Head,Aquatic Ecology Section,1978 to date;Fisheries Blologist/Limnologist,
1976-78.
Experience Highlights:
Responsibilities include design,management,and quality control of aquatic ecological Investigations,assessments,
and reports.Conducts resource assessments and impact analyses for both domestic and overseas projects.
Project Manager for the Williamson NO.2 Mine Project,Illinois.Supervised and directed environmental and
engineering work related to coal mine reclamation and mitigation of acid mine drainage.
Conducted field reconnaissance and prepared environmental impact report for the Yacyreta Project on the Rio
Parana between Argentina and Paraguay,including evaluation of biological,cullur<Jl,and economic aspects of
the project area.
Assessed impacts on aquatic ecosystems resulting from the rehabilitation of Lock and Darn NO.1 on the
Mississippi River,Minnesota.
Prepared a feasibility report on pumped-storage development at Bluestone Lake,West Virginia,for the U.S.
Army Corps of Engineers.
Participated in an environmental assessment of the construction and operation of a proposed nuclear power
plant and cooling water reservoir,Indiana.
1975 to 1976:
Tulane University,New Orleans,Louisiana.
I nstructor.Taught courses in general biology,general botany,and zoology,and sem in<Jrs in I imnology and aquatic
ecology.Conducted research on the effects of environmental factors on the growth rates of fishes.
GERALD I.BRESNICK
1972 to 1975:
Biological Consultant,New Orleans,Louisiana.
Responsible for water quality analysis and interpretation,fish collection and identification,and analysis of
existing water pollution control treatment facilities with emphasis on effects of ichthyofauna.Specialized in
determining and evaluating aquatic impacts of pulp and paper mill effluents and domestic sewage.
Technical Papers and Articles:
"The Ecological Life History of the Cherryfin Shiner,Notropis roseipinnis IHay):'with D.C.Heins,Trans.Amer.
Fish.Soc.104(3).pp.514-521,1975.
"Age and Growth of the Weed Shiner,Notropis texanus (Girard):'with D.C.Heins,Amer.MidI.Nat.98,
pp.495-499,1977.
Reviewer of sections on dissolved oxygen and mixing zones,USEPA "Red Book,"1978.
"The Effects of Stream Channel ization on the Life History of the Cherryfin Sh iner ,"presented at the Annual
Meeting of the Association of Southeastern Biologists,1974.
"Environmental Evaluation Based on the Relative Growth Rates of Fishes:'Ph.D.Dissertation,Tulane University,
1975.
"Tagging and Marking of Fishes,"Monograph,1973.
Author or coauthor of over 20 professional reports.
2/79
-
-
SUSAN E.BRODY
Urban and Regional Planner
EDUCATION
Master of City Planning,Massachusetts Institute of
Technology,1977
M.A.,Pol itical Science,University of Cal ifornia at Santa
Barbara,1973
B.A.,Political Science,Reed College,1971
EXPERIENCE
Ms.Brody is a member of the planning and economics depart-
ments,where she special ;zes in the areas of socio-economic
impacts,pol icy analysis and land use planning.Her recent
experience at CH2M HILL includes:
o Investigation of the social and economic impacts of
offshore oil development in Alaska's LOlrJer Cook Inlet
and formulation of strategies to meet impact-related
needs.
o Design of a procedures manual to help guide developers
through the permit regulatory processes within Alaska.
o Eva 1ua t i on of the hous i ng,Iand use,and managemen t
alternatives for Beluga coal field development in the
Cook Inlet region of Alaska.
o Preparation of a land use plan for the Ci ty of Seward,
Alaska.
o Consul ting planning to the City of Homer,Alaska.
a Assistance to the State of Oregon's Outer Continental
Shelf Task Force in preparing a report on the impacts
of offshore oi I and gas development and recommendat ions
for future action.
Before joining CH2M HILL,Ms.Brody participated in an MIT
research project to develop policy options for state
governments deal ing with the social and economic impacts of
energy facility siting in the western United States.During
this time she also served as a consultant to the Edgartown
Open Space Planning Project On the island of Martha's Vineyard,
Massachusetts.This work involved natural resource mapping
and an evaluation of methods for acquiring shorefront access
and preserving recreational and scenic resources.
-
,ENGINEERING COMPANY
Professional Engineer -Engineer-in-Training,Illinois
LARRY B.BUETI KOFER
Water Resources Engineer
Degrees:
Languages:
Master of Science in Civil Engineering (Water
Resources Planning)
University of Illinois,1973
Bachelor of Science in Civil Engineering
Syracuse University,1977
English and Spanish
-
Professional Societies:
American Geophysical Union
American Society of Civil Engineers
American Water Resources Association
Illinois Society of Professional Engineers
International Water Resources Association
National Society of Professional Engineers
Harza Engineering Company si nce 1973.
Water Resources Division:Water Resources Engi neer,1973 to date.
Experience Highlights:
Participated III water resources planning and hydrological studies.Specifically dealt with flood analyses
and control.stochastic streamflow generation,drought analyses,hydroeconomlcs,river basin planning,
site development and computer applications.
Projecl Manager for preparation of a flood study for the City of Janesville,Wisconsin.Water surface
profiles were developed for future use in formulation of structural flood control measures and for
land-use zoning.
Project Manager for Great Lakes-St.Lawrence Seaway Navigation Season ExtenSion Demonstration
Program/Survey Study.Responsibilities included coordination with the client (Detroit District,U.S.
Army Corps of Engineers),attendance at Winter Navigation Board Meetings,Working Committee
Meetings,and Public Meetings;Administration and coordination of Harza PrOject work;and report
writing and prepara tion.
1971 to 1973:
University of Illinois.
Graduate Research Assistant.Department of Civil Engineering.Contributed to research project
entitled:"Hydrologic Models of the Great Lakes."
LARRY B.BUETI KOFER
1971 :
Stearns &Wheler -Civil and Sanitary Engineers.
Engineer.Worked on Madison County New York Comprehensive Water Supply Study.Primary
duties trlcluded hydrological analysis,economic analysis,and report writing.
Technical Papers and Articles:
Research Papers -
"Annotated Bibliography on Great Lakes Hydrology,"(with Dr.Dale D.Mer'edith),University of
IllinOIS Water Resources Center,Research Report No.56,62 pages,September 1972.
"A Survey of Selected Rainfall Runoff Models with Emphasis on the Stanford Watershed Model"
Unpu bl ished,92 pages,January 1972.
6/75
...
ENGINEERING COMPANY
Professional Engineer ~Texas,Virginia
Professional Soci ety:
American Society of Mechanicdl Engineers
RICHARD S.BURKHART
Associate,Assistant Chief Mechanical
Design Engineer,and Head,
General Mechanical Division I
Bachelor of Science in Engineering Science
North Central College,1959
Degree:
Harza Engineering Company 1959-60;1962·73;Since 1977.
Associate,1978.
-
Mechanical Design Branch·Assistant Chief Mechanical Design Engineer and Head,General Mechanical Division I,
1977 to date;Department Head,1972·73;Computer Division Head,Systems Analysis Department,1971-72;
Mechanical Division:Section Head,1970-71;Compu ter Division·Production Manager,1970,Mechanical Division.
Group Leader,1967-70;Mechanical Engineer,1962-67;and 1959·60.
Experience Highlights:
In the absence of the Chief Mechanical Design Engineer,responsible for technical direction and administration of
mechanical engineering for all projects engineered by the Company including gates,cranes,hoists,hydraulic
turbines and pump turbines,governors,combustion turbines,pumping,mechanical auxiliary equipment and
heating,ventilating and air conditioning.
As Division Head,direct the work of a division responsible for all general mechanical engineering work on hydro-
electric powerstations,diesel and gas turbine installations,pumping plants and related proJects.Major pro)8cts
include the 10,000·MW Guri Final State PrOjeCt,Venezuela,and the 2100·MW Bath County Pumped-Storage
Project,Virginia.
Assistant Project Manager for the 1000-MW Mount Hope Underground Hydroelectric Pumped-Storage Project.
New Jersey,during the feasibilitY study.Also responsible for all mechanical work related to studies of compressed
air energy storage for the project.
As Head of the Systems Analysis Department,was responsible for all electronic computer opGrilllOns of HiJrza
using in-house equipment and a variety of leased computer equipment.Supervised preparation and operation of
computer programs including hydraulic,hydrologic,statistical and structural analyses and personnel,accountlllg
and budget analysis for internal company operations.Duties encompass provision of computEJr services to all
divisions of the company,selection of computer equipment,and evaluatiny and securing new programs for outside;
sources as well as general administration of the department.
Supervised the field vibration testing of an arch dam and the penstocks at the SIT1ith Mountain Pumped-Storage
Project,Virginia.
Measurements Engineer for turbine model tests of 303,000 mhp Francis turbines for the Guri Hydroelectric
Project,Venezuela.
RICHARD S.BURKHART
Participated in field testing of electric-hydraulic governors for the 40-MW Rio Lindo Project,Honduras.
Assistant Project Manager for a feasibility study for the National Aeronautics and Space Administration concerning
the application of hydraulic turbine drives to a transonic wind tunnel.
Mechanical and Hydraulics Measurements Engineer for turbine and generator acceptance tests and load rejection
tests for the Malpaso Powerhouse,Mexico.
Wrote technical computer programs in the Fortran Language.Programs written included programs for stress
analysis of hydraulic turbine components;programs for turbine speed regulation and index test analysis and a
program to simulate water quality for pollution studies.
Responsibilities as a Group Leader included preparation of engineering studies,design memoranda,contract
drawings,and contract documents for the 100-MW Finchaa Project,Ethiopia,and the 40-MW Rio Undo Project,
Honduras.Work covered all mechanical piping systems and auxiliary equipment and portions of the work
relating to hydraulic turbines,governors,valves,cranes and hoists.
1973 to 1977:
Brown &Root,Inc.,Houston,Texas.
Department Senior Staff Engineer.In responsible charge of all mechanical work for the Water Supply and Heavy
Civil Engineering Department.Directed mechanical design for a 160 cfs pumping station for the Manatee Power·
plant and Reservoir,Florida;a 800 cfs pumping station for the Martin Powerplant and Reservoir,Florida;a 200
cfs station for the Sooner Powerplant and Reservoir,Oklahoma;a 160 cfs irrigation pumping station on the Brazos
River,Texas;and a 1200 cfs pumping station for the South Texas Nuclear Project,Texas.
Served for two years as Project Manager for the $30,000,000 reservoir and pumping station for the Martin
Powerplant,Florida.
1960 to 1962:
U.S.Army.
Project Engineer.Performed research and development work in dynamic testing of diesel and gasoline powered
military track and wheeled vehicles and vehicle transported weapons systems.Duties included supervision of
testing,evaluation of test data,and preparation and issuing of final test reports.
B/7B
Date of Birth:
Citizenship:
Degrees:
Language:
Professional
Registration:
Professional
Societies:
Honorary
Society:
June 1976
to Date:
HARZA ENGINEERING COMPANY
EDWARD F.CARTER
Power Planning Engineer
February 12,1947
U.S.A.
Bachelor of Science in Civil Engineering,
Magna Cum Laude
1976,Syracuse University
Bachelor of Science in Forest Engineering,
Magna Cum Laude
1975,State University of New York,
College of Environmental Science and
Forestry
English
Professional Engineer -Wisconsin
American Society of Civil Engineers
Illinois Chapter ASCE
Tau Beta Pi
Harza Engineering Company,Chicago,Illinois.
Power Planning Engineer.Power Resources Division.
Participated i~the expansion studies of the lower
Susquehanna River hydro plants.Responsibilities
include project layout,quantity and cost estimates,
power operation computer studies and selection of
optimal expansion scheme.
Participated in modernization and expansion studies
related to the Holtwood Hydroelectric project.
Responsibilities included power and energy studies,
project layout and cost estimates,~conomic analysis
for selection of the optimum scheme and preparation
of the report.
Participated in economic and financial analyses
for the ENEE Generation System Expansion study,
Honduras,C.A.Responsibilities included forecast
of expenditure schedules,determination of equalizing
discount rates for various generation mixes,selection
EDWARD F.CARTER
Power Planning Engineer
-2-
-
-
June 1976
to Date:
(continued)
Sununer Employment
1972 to 1975:
February 1970
to January 1972:
October 1966
to January 1970:
April 1978
of power expansion program,sensitivity analyses,
effects of construction delay on reconunended program,
economics of rural electrification and financial
justification of the reconunended system expansion
program.
Participated in the preparation of construction
plans and schedules for the rehabilitation of Lock
and Darn No.1 on the Mississippi River for the St.
Paul District Corps of Engineers.Temporary assignment
to the Construction Management Division,Scheduling
Department,July,August and September 1977.Responsibilities
included material quantity takeoffs,development of
feasible construction approach and critical path
method (CPM)scheduling for construction.
J.S.MacNeil Jr.,Inc.,Homer,New York.
Assistant Technical Engineer.Responsible for
construction quality control,Joseph Schlitz Brewery,
Baldwinsville,New York.
Vincent J.Smith,Inc.,Syracuse,New York.
Assistant Technical Engineer.Responsible for
interpreting the architectural and structural drawings
of a multi-story hospital addition and relating the
information to field p~rsonnel.
D.W.Winkelman,Inc.,Syracuse,New York.
Assistant Technical Engineer.Survey instrument
work related to interstate highway route location.
Vincent J.Smith,Inc.,Syracuse,New York.
Assistant Technical Engineer.Responsible for
interpreting the architectural and structural drawings
of a multi-story library and relating the information
to field personnel.
Un~ted States Navy.
Petty Officer.In charge of a twelve-man survey
department.Responsible for the survey portion of
major construction and reconstruction projects in
the Republic of Vietnam.
ENGINEERING COMPANY
Professional Engineer -Illinois
DANIEL J.CASTELLANI
Planning Engineer
Harza Engineering Company since 1966.
Power Resources Division:Planning Engineer,1975 to date;
Head,Computer Department,1972-75;Applied Mechanics
Division:Structural Engineer,1970-72;Computer Division:
Systems Analyst,1968-70;Engi neering Programmer,1966-67.
Master of Science in Civil Engineering
University of Notre Dame,1965
Bachelor of Science in Civil Engineering
University of Notre Dame,1963
Degrees:
Experience Highlights:
Responsible for interior drainage analysis of eight leveed communities on the Souris River near Minot,North
Dakota.The analysis included the design of stormwater interceptors,and the sizing of stormwater pumping
stations and gravity outlets.The work was performed for the St.Paul District of the U.S.Army Corps of
Engineers.In conjunction with the above project,was also responsible for the layout of the spillway and outlet
works for both Burlington Dam and the Des Lacs River Diversion Dam.
Performed compu ter simulation of reservoir drawdown study to determ ine generat"lng capacity for Reza Shah
Kabir Dam,Iran.
Responsible for management of all data processing functions,including both commercial and engineering
applications.In-house facilities included an IBM 1130 computer system and a Cope 1225 remote batch
terminal.Experienced in Fortran programming on IBM-1130,IBM-360/195,IBM-370/158,CDC-6600 and
Univac-1108.
Performed analysis and reviewed design of transmission towers for Guri Project,Venezuela;Finchaa Project,
Ethi apia and CE L system expansion,EI Salvador.Inspected transm ission tower tests at Cheddar,England and
two at Sarajevo,Yugoslavia.Performed computer tower spotting and sag-tension analysis for 2 major transmission
lines.
Developed and programmed numerous computer programs including SAPLT,which checks and plots the input
data for SAP,a finite element Structural Analysis Program;RDLBO,which calculates and plots the development
of redUCing elbows -used in designing Guri penstocks;AG EOM,which plots the geometry and shape of double
curvature arch dams -used on Reza Shah Kabir Dam,Iran;KARUN,which calculates corrected stress and strain
of strain gauge clusters imbedded in mass concrete;SHAFT,which calculates the resonant frequency of turbine-
generator shafts.Performed all prograOlming for "Estimating Costs of Hard Rock Tunneling"(COHART),for
the U.S.Department of Transportation.
-
DANIEL J.CASTELLANI
1965 to 1966:
University of Notre Dame.
Completed course requirements for Ph.D.in Civil Engineering.Laboratory I nstructor in the National Science
Foundation Summer Institute on Structural Mechanics.
Technical Papers and Articles:
Unpublished Master's thesis submitted to the University of Notre Dame,June,1965 -"Buckling Characteristics
of Prestressed Concrete Columns."
6/76
ENGINEERING COMPANY
-
Professional Societies:
Professional Engineer -Illinois
EDWARD M.CIKANEK
Department Head
Master of Science in Civil Engineering
University of Notre Dame,1966
Bachelor of Science in Civil Engineering
Northwestern University,1964
Degrees:
American Society of Civil Engineers (Memberl
National Society of Professional Engineers
Illinois Society of Professional Engineers
International Society for Rock Mechanics-
Harza Engineering Company since 1966.
Foundation and Soil Mechanics Division:Head,Underground Projects Department,1976 to date;Section Head,
1972-76;Group Leader,1968-72;Engineer,1966-68.
-
-
Experience Highlights:
Supervised foundation and embankment design studies and preparation of Corps of Engineer Design Memoranda
for Calion Lock and Dam in Arkansas.Topics included structure settlement,structure and slope stability,
excavation dewatering,construction material surveys and instrumentation of foundations and structures.
Supervised foundations and embankment design studies for Burlington Dam in North Dakota.Topics included
dam stability and settlement,diversion tunnel design,upgrading of existing flood control levees and stabilization
of existing structures.
Supervision of design studies for tunnels in rock and earth and for underground excavations in rock.
Project Manager for developing a computer program for estimating the costs of soft ground and cut-and·cover
tunnels and for combining it with COHART,a computer program for estimating costs of hard rock tunneling.
This formed a computer program,COSTUN,capable of estimating costs of rock,soft.ground,and cut-and-cover
tunnels in a single computer run.Previously supervised design studies for,and the development of,COHART.
Co-authored final reports for COHART and COSTUN.
Supervised studies to determine preliminary tunnel locations and the optimum development of surface reservoirs
for the Chicago,Illinois Tunnel and Reservoir Plan (TARP).Subsequently supervised studies leading to final
selection of tunnel alignment,excavation method,and lining type and developed grouting and support requirements.
Prepared construction specifications and appropriate portions of final design report.Supervised similar studies and
proposed specifications for two underground pump stations and related tunnels and shafts.
Supervised tunnel design studies and preparation of contract documents for the Washington,D.C.Subway,Section
A-6.Topics included tunnel linings and supports,construction methods,specifications and payment methods.
Supervised Tunnel design studies for Bath County pumped-storage project.
EDWARD M.CI KANEK
Participated in the planning studies of alternative routes for a coal conveyor in Ohio,including a comparison
of tunnel and surface routes.
Supervised design studies for pile foundations in Louisiana;revised and expanded a computer program for
Hrennikoff's solution of pile foundations.
Performed various embankment design studies for Lake Michigan Offshore Airport.Made preliminary design
studies for a 400-mile tunnel for High Speed Ground Transportation from Boston to Washington,D.C.and
assisted in writing the final report.Assisted in writing Harza Guide technical specifications for fills,excavations,
drilling and grouting.
Supervised foundation exploration and soil testing for the 100-MW Finchaa Project,Ethiopia.
1964 to 1966:
University of Notre Dame.Full-time graduate student pursuing course leading to Master of Science Degree in
Civil Engineering.
Technical Papers and Articles:
Unpublished Master's The~;s submitted to the University of Notre Dame,June,1966,"Porewater Pressures in
Partly Saturated Sands."
"A Computer Program for Estimating Costs of Tunneling,"presented to June 1974 Rapid Excavation and
Tunneling Conference,San Francisco,Co-authored with Frank T.Wheby.
4/78
-
II FLOYD J.DAMRON
Civil Engineer
Education
M.S.C.E.,University of Alaska,Fairbanks,1973
B.S.C.E.,University of Alaska,Fairbanks,1971
Un iversi ty of AI aska,Fi sh Ha tchery Design,Short Course,
1976
University of Texas,Flood Plain Hydraulics and Hydrology,
Short Courses,1976
Colorado State University,Modeling of Rivers,Institute of
River Mechanics,1977
University of Iowa,Ice Engineering,Short Course,1978
U .S.Army Corps of Engineers,Phase I Dam Sa fety Inspection,
Short Course,1978
Experience
Mr.Damron has served as project engineer and design engineer
on a variety of hydrologic,water resource,and general civil
engineering projects in Alaska.His background includes
experience in:municipal water supply investigations,flood
studies,flood routing,drainage studies,fish hatchery and
treatment plant hydraulic design,a hatchery site study,water
quality monitoring,structural design of a sheet pile dam,
design of various parking lots and sidewalks,and owner's
representative for construction projects.
Some typical projects on which Mr.Damron has worked are:
-
I,
7
•
•
Project manager for a hydrologic investigation at the
proposed new capital site near Willow.Close coordi-
nation with agencies and other consultants was re-
qui red for the acqu i si tion of envi ronmental assessment
data.Extensive surface and subsurface exploration
was conducted,including water well design and test
pumping.
Project engineer for 10 Flood Plain Information Reports
and a major flood insurance study of coastal communi-
ties.Duties included cost estimation and con tract
administration,coordination of other consultants,
hydrologic and hydraulic analysis by computer model-
ing of all riverine and lacustrine flooding,and pre-
paration of final maps and reports.One model was
unique in that dumping glacial lakes produce the
p r inc i pa 1 fI ood ing .
•Design and <Jnalysis of floodway and seepage collec-
tion channels for the Corps of Engineers'Moose Creek
Dam (flood control project for Fairbanks).The flood-
way is designed to carryall excess flow in the Chena
FLOYD J.DAMRON
River (80,000 cubic feet pe(second)to the Tenana
River.The seepage channel design (4,000 cubic
feet per second)was designed curvilinear for aesthe-
tics and si zed to prevent downstream flooding due to
dam seepage duri ng uti Ii zation of the floodway.
II Principal design engineer for the Ship Creek Hatchery,
Ancho;age.Responsi bi I ity incl uded des ign of the
hydraulic system for the hatchery.The 16-cubic-
feet-per-second design included the capability of
varying the temperat'Jre in each fish rearing raceway
by mixing excess hot power ~eneration cooling water
with cold creek water.As p;--incipal design engineer
on a subsequent study for expansion of the hatchery,
responsible for detai led analysis of the stream flow,
augmentation of flow with shallow wells,water reuse,
existing system modification,and shallow well injec-
tion of excess power plant cool ing water for later use.
•Drainage engineer for Anchorage International Airport
North-South runvvay project.Responsibility included
the establishment of design flows and pipe sizing for
the collection system.Design flow of the outfall ex-
ceeds 100 cubi c feet per second.
•Ownerls representative for a North Slope winter con-
struction project which included the rehabilitation of
a landing strip,seven miles of ice road construction,
and excavation and placement of 40.000 cubic yards
of gravel for a drilling pad.Environmental protec-
tion was closely monitored throughoLit the project.
Profession3;Registration
Alaska
Membership in Organizations
Alaska Ground Water Association
Alask3 Society of Professional Engineers
American Society of Civi I Engineers
National Society of Professional Engineers
Publ ications
"Water/Wastewater Evaluation of an Arctic Alaskan Industrial
Camp,II University of Alaska,1972
ENGINEERING COMPANY
PETER A.DICKSON
Geologist
Degrees:
Languages:
Doctor of Philosophy in Geology
University of Pittsburgh,Pennsylvania,1977
Master of Science in Geology
University of Manchester,England,1974
Bachelor of Science in Geology
University of Leeds,England,1971
English,French,and knowledge of
German and Turkish
Professional Societies:
Geological Society of America
I nternational Paleontological Union
Paleontological Society
Harza Engineering Company since 1978.
Geologist,Geology Division,1978 to date.
Experience Highlights:
In Chicago office,assists in preparation of exploration programs and interprets regional and site structural geology
for Jordan Valley I rrigation Project,Maqarin Dam Site.Works on petrography,clay mineralogy,paleontology,
and general geological studies of the project site,including LANDSAT imagery and writing of reports.
Instrumental in construction of a three-dimensional model of the site geology.
Resident Field Geologist for prefeasibility investigations,Brumley Gap and Powell Mountain Pumped-Storage
Projects,Virginia (March to November 1978).Responsibilities included regional and site mapping of stratigraphy
and structure,preparation of field reports and geologic sections,and investigation of karstic land surfaces.
Assisted in preparation of exploration programs,including a literature search of the region's geology.
1977 to 1978:
Gul f Research and Development Company,Pittsbu rgh,Pennsylvania.
Geological Field Consultant.Collected and interpreted detailed structural and stratigraphic data as part of a
LAN DSAT research project.
1975 to 1977:
University of Pittsburgh,Pittsburgh,Pennsylvania.
Research Assistant and Teaching Fellow in Geology.Research involved stratigraphic and petrologic investigation
of coal-bearing rocks in Appalachian coalfield region,including coal petrography and field mapping.
PETER A.DICKSON
1971 to 1975:
University of Manchester,England.
Research Assistant to Dr.R.M.C.Eagar.Studies included geologic field work in cooperation with various
State Geological Surveys and coal companies,in the coalfield regions of England,Wales,northwest Spain,
the Appalachian Mountains,and Illinois.Responsibilities included detailed stratigraphic and petrologic
interpretation from core log and field data,and field mapping.
1967 to 1971:
University of Leeds,England.
Graduate Student.
5/79
ENGINEERING COMPANY
PETER DONAlEK
Electrical Engineer
Degrees:
Languages;
Master of Arts -Mathematics
University of Toledo,1973
Master of Science in Electrical Engineering
University of Pennsylvania,1970
Bachelor of Science in Electrical Engineering
University of Illinois,1961
Engl ish,speaking and reading knowledge of Portuguese,
and reading knowledge of French.
Professional Engineer -Illinois
Professional Societies:
Institute of Electrical &Electronics Engineers
Chairman,Task Force on Discrete Supplementary Controls for Stability
Society for Industrial and Applied Mathematics
The Mathematical Association of America
Western Society of Engineers
Harza Engineering Company since 1973.
Sen ior Electrical Engineer,1974 to date;Electrical Engineer,1973-74.
Experience Highlights:
Project Manager for a study and report on technical and economic feasibility of coal mine-mouth generation and a
765-kV transmission network in the United States.
Project Manager for a study and report for electric utility interface requirements and siting of solar power satellite,
5,000-MW rectifying antennas.
Directed a transient network analyzer study for 500-kV transmission line in Pakistan.
Project Manager on the evaluation of transmission system expansion for the State of Montana.
Designed load shedding system for EI Salvador bul k power transmission system.
Planned for expansion of power transmission system in EI Salvador.
Prepared specifications for oil minimum circuit breaker.
Evaluated a battery system as an alternative to pumped-storage hydro for use in Federal Power Commission license application.
Prepared load flow,short circuit,and stability computations used in developing a twenty-five year system expansion plan
for the Republic of South Korea.
Prepared preliminary cost estimates for the electrical portion of various pumped-storage and hydroelectric generating stations.
PETER DONALEK
Prepared cost estimates for various high voltage substations.
Prepared alternative electric systems and auxiliary electrical equipment for pumping stations,including studies of
motor starting methods for the Chicago Tunnel and Reservoir Project.
1971 to 1973:
University of Toledo,Toledo,Ohio.
Graduate Teaching Assistant.Worked on Masters degree in mathematics and taught undergraduate mathematics
courses.
1969 to 1971:
Spring Garden College,Philadelphia,Pennsylvania.
Assistant Professor.Taught introductory courses in electromechanics and electrical power systems.Was in charge
of the A.c.Network Analyzer.
1965 to 1968:
Sargent &Lundy Engineers,Chicago,Illinois.
Electrical Engineer.Performed electrical power system design studies.Prepared economic comparisons of
alternative power plant expansion plans,and analysis of substation short circuit and relay problems.
1963 to 1965:
United States Peace Corps,Brazil.
Electrical Engineer and Designer for rural electrification projects in the San Franc'lsco River Valley.The work was
done in conjunction with the Brazilian government agency Comissao do Vale do Sao Francisco,similar to the U.S.
Bureau of Reclamation.
1961 to 1963:
Westinghouse Electric Corporation,Baltimore,Maryland.
Field Serv'lce Engineer.Part of a group responsible for the re-design of the radar system used in U.S.Navy aircraft.
6/79
ENGINEERING COMPANY
Professional Societies:
EUGENE F.DUDLEY
Senior Ecologist
Doctor of Philosophy in Wildlife Management
University of Michigan,1963
Master of Science in Zoology (Ecology)
University of Michigan,1954
Bachelor of Science (Zoology)
Yale University,1953
Degrees:
International Water Resources Association
Illinois Association of Environmental Professionals
The Wildlife Society
Civic Activities:
Vice Chairman,Planning and Zoning Commission of home community
-
Harza Engineering Company since 1970.
Environmental Sciences Division:Senior Ecologist,1974 to date;Ecologist,1970-74.
Experience Highlights:
Organize and supervise evaluations of potential effects of water and land developments on ecologic systems and natural
resources.Review compliance of ex isting and proposed developments with the Na tional Environmental Pol icy Act and
guidelines established by international financing agencies.Prepare Environmental Assessment and Impact Reports.
Project Manager of studies of environmental impact and recreation potential of nuclear power installations,
reservoirs built for nuclear and fossil fuel power plant cooling,hydroelectric power generation,irrigation,flood
control,and municipal and industrial water supply,and of non-structural measures for land and water management.
Managed and had overall responsibility for environmental inventories,assessments,and impact evaluations for
more than twenty projects.Experience includes the evaluation of impacts on the terrestrial and aquatic;
environment,aesthetics,existing and potential recreation opportunities,access,social and cultural characteristics,
and pu bl ic health and safety.
Environmental coordinator for the 2,700-MW Yacyreta Hydroelectric Project on the Rio Parana,Argentina and
Paraguay.Impacts and resource development opportunities were evaluated in accordance with policies of the
World Bank and the lnteramerican Development Bank.Special attention was devoted to ecologic impacts
on endangered species,fishery resources and water quality,and to social 'Impacts,including the resettlement of
approximately 30,000 residents.Long-term programs were formulated for water quality management,fishery
production,natural preserves,and regional land use planning.
Prepared Exhibit W (Envi ronmental Report)for FE RC I icense application for the 'InS lallation of a fourth u nit of
the Mayfield hydroelectric station,Cowlitz River,Washington.Prepared analyses of effects on fisheries and riparian
resources resulting from changes in project outflows.Assisted the City of Tacoma in a series of meetings with
EUGENE F.DUDLEY
the fishery agencies to establish acceptable high and low flows and In the preparation of reports to the agencies
and FE RC.Local and agency concerns and actual physical and biological condi tions in the project area were
integrated into a program that was ultimately acceptable to all parties.
Conducted environmental inventories and impact assessments for alternative measures for reduction of loca!flood
damage at Webster City,Iowa.Similar investigations were performed for a project at Fredericksburg,Virginia,
where certain al ternatives would affect estuarine waters.
Provided environmental assessmenLs for alternatives identified in power plant siting surveys in Wisconsin,Michigan,
Maryland,and West Virginia.
Performed and coordinated field investigations and assessments of impacts on freshwater and estuarine marsh
resulting from agricultural development in Jamaica.
Other assignments have included analyses of environmental impacts of water resource development projects,and
planning for pollution abatement,recreation,fisheries,and other enhancement measures on projects in the United
States and overseas.Typical projects included the multipurpose Northside development project,Washington;
Springer Lake Project,Illinois (independent review for University of Illinois);irrigation developments in Jordan
and Guyana;and hydroelectric projects on the Chimbo River,Ecuador,Patia and Sogamoso Rivers,Colombia,
the Mazaruni River,Guyana,the Lempa River,EI Salvador,and the Bermejo River,Argentina.
1967 to 1970:
Bureau of Sport Fisheries and Wildlife,U.S.Department of the Interior,Boston,Massachusetts.
Fish and Wildlife Biologist.Staff Biologist,Division of River Basin Studies,Chief of Section of Special Studies.
Reviewed the impact on environmental quality and natural resources of hydroelectric and atomic power facilities
and watershed developments for II ood control,navigation,and other water related act ivities.
1961 to 1967:
Department of Epidemiology,School of Public Health,University of Michigan,Ann Arbor,Michigan.
Research Associate in Epidemiology,Ecologist for the Tecumseh Community Health Study,Center for Research
in Diseases of the Heart,Circulation,and Related Disorders.
Studied the relationships between the biological and physical environment and human health.Factors
considered included vegetation and land use,fauna,climate,and human and animal diseases.
Technical Papers and Articles:
"Climate,Water Hardness,and Coronary Heart Disease,"with R.A.Belden,and B.C.Johnson,Journal of
Chronic Diseases 22 (1)pp.25-48,1969.
"Environmental Aspects of Site Selection,"ASCE Power Division Journal,pp.21-28,June 1972.
"Petenwell-Castle Rock,Twenty Years Later,"with W.T.Bristow,prepared for the 11th ICOLD Congress,
Madrid,1973.
12/78
-ENGINEERING COMPANY
BRIAN J.GALLAGHER
Associate and
Head,Environmental Sciences Division
Degrees:
Languages:
Doctor of Environmental Science and Engineering
University of California,Los Angeles,1977
Master of Science in Civil Engineering (Water Resources)
University of Wisconsin,M ilwau kee,1972
Bachelor of Science in Mathematics and Physics
University of Wisconsin,Milwaukee,1967
Engl ish and work ing knowledge of Spanish and German
-
-
Professional Engineer -Wisconsin
Professional Societies:
American Society of Civil Engineers
American Society of Limnology and Oceanography
I nternational Water Resources Association
Harza Engineering Company since 1977.
Associate,1979.
Head,Environmental Sciences Division,1977 to date.
Experience Highlights:
Supervises interdiscipl inary team of scientists,engineers,and planners conducting resou rce investigations,ecosystem
analyses,and environmental impact assessments.Responsible for overall direction of regulatory and permitting
assistance to cI ients on resource development projects both domestic and international.
Project Director for southern Illinois abandoned coal mine/acid drainage control and reclamation project,1978-79,
Directed and reviewed all studies,reports,and recommendations,and represented client before regulatory agencies
for plan approvals.
Acting Senior Professional Staff reviewer on water availability assessments and water quality analyses for the "Upper
Missouri River Basin Coal Development Scenarios,"including advanced coal conversion technologies,1978,
Directed in-house development of computerized program management system for similarity,scheduling,and control
of mul tidiscipl inary tasks involved with resou rce development projects and permit and license acqu IS'ltions,1978-79.
1976 to 1977:
Pri ncipal of own fi rm providi ng envi ronmental consulti ng services to industry and governmen tal agencies.Pri ncipal
I nvestigator on appl ied research contract for U.S.Army Engi neer Waterways Ex periment Station,Vicksbu rg,
Mississippi,on design of dredged material sedimentation basins and discharge structures.Director and principal
author of EPA facility planning projects (201 studies)for major wastewater collection and treatment projects in
Michigan.Served as special advisor on water quality modeling of the Morava River in Yugoslavia for a United
Nations Development Program.
BRIAN J.GALLAGHER
1975 to 1976:
University of California,Los Angeles,California.
Research Fellow.Conducted interdisciplinary research of Sierra Mountains Alpine Lakes water quality,offshore 011
development environmental impacts,and environmental effects of coal gasification residual waste disposal.
1968 to 1975:
Limnetics Incorporated,Milwaukee,Wisconsin.
President and Chief Executive Officer of an environmental consulting firm providing professional services to electric
utilities,fossil·fuel development industries,and governmental agencies.Designed and directed major ecological studies
of municipal and industrial discharges,cultural eutrophication,recreational area development,thermal effects from
power plant operations,artificial cooling lakes,and environmental impacts of oil shale development projects.
1959 to 1967:
General Motors Corporation,AC Electronics Division,Milwaukee,Wisconsin.
Senior Project Engineer.Systems engineer responsible for development,testing and integration of inertial guidance,
radar navigation,and radiometric sextant components for aerospace and marine vehicles.
1958 to 1959:
Hughes Aircraft Company,Culver City,California.
Electronics Instructor.Taught courses on integrated fire control and navigation avionic systems.
Technical Papers and Articles:
Editor of "Energy Production and Thermal Effects,"Ann Arbor Science PUblishing Company,1973.
Author and coauthor of over 20 publications and professional reports on environmental matters,including the following
"Investigation of Containment Area Design to Maximize Hydraulic Efficiency of Confined Disposal Areas,"Final
Report,U.S.Army Corps of Engineers Research Contract No.DACW39-76-C·0124,Waterways Experiment Station,
Vicksburg,Mississippi,1978.
"Environmental Effects of Coal Gasification,"IWRA,Proceedings of the International Symposium on Fossil Fuel
Production and Water Resources,Dusseldorf,Federal Republic of Germany,1976.
"Water Quality Effects of a Dredgings Disposal Area,"with R.J.Krizek and G.M.Karadi,Journal of the American
Society of Civil Engineers,Environmental Engineering Division,Vol.102,No.EE2,pp.389-409,April 1976.
5/79
ENGINEERING COMPANY
DWIGHT L.GLASSCOCK
Vice President and Head,
Hydroelectric Design Branch
Professional Engineer -California,Connecticut,Illinois,Maine,
Maryland,Massachusetts,Michigan,Nebraska,New Hampshire,
New York,North Carolina,Ohio,Oklahoma,Pennsylvania,
South Carol ina,Virginia,Wisconsin,and Nova Scotia
Degrees:Master of Science
University of Illinois,1947
Bachelor of Science in Civil Engineering
University of Illinois,1944
-
Professional Societies:
American Society of Civil Engineers
American Consulting Engineer Council
Newcomen Society in North America
U.S.Committee on Large Dams
Harza Engineering Company since 1978.
Hydroelectric Design Branch:Vice President and Head,1978 to date.
Experience Highlights:
Responsible for the design of hydroelectric projects,primarily in the United States.
1952 to 1977:
Chas.T.Main,Inc.,Boston,Massachusetts.
Hydroelectric Power and Water Resources Division:Vice President,General Manager,1971-77;Project Manager,
1964-71;Project Engineer,1958-64;Design Engineer,1952-58.
Responsible for the technical design activities,construction management,project staffing,work scheduling,and
performance of the project teams of the division.The scope of engineering services provided by the division covered
reconnaissance studies,feasibility studies,all disciplines of detailed design,construction management,and start-up
operation.Operations included both domestic and international projects with work undertaken concurrently in the
U.S.,South America,Africa,and Asia.
Responsible for the direction,coordination,and execution of design for the 1,OOO-MW Blenheim-Gilboa Pumped-
Storage Development,New York State.
Directed feasibility study for the trans-basin diversion of the Capivari River for augmentation of the Sao Paulo,Brazil,
water supply.Responsible for liaison and administration of Rio de Janiero and Sao Paulo,Brazil,offices of the
company for the design of the 1,400-MW Marimbondo and 1,380·MW Agua Vermelha Hydroelectric Projects.
DWIGHT L.GLASSCOCK
Responsible for design and construction management for the Alternating Gradient Synchroton Conversion Project,
Brookhaven National Laboratory.This complex involved facilities for high energy physics research and included
buildings,shielding,and mechanical and electrical services.
Supervised a study for the regulation of the outflow of Lake Ontario which reviewed the existing regulating scheme
and investigated alternative regUlation plans,to determine the economic effect on the power generating facilities of
the St.Lawrence Power Project.U.S.and Canada.
Responsible for the economic studies and analyses in conjunction with the comprehensive review and preparation
of the engineering feasi bil i ty report for the California Water Plan.Th is plan provided for the conservation of
northern California water and its transportation to the Central Valley and southern portion of the state.
Directed a power study for the Province of Nova Scotia,Canada,that included a forecast of load growth,power
transmission and interconnections studies,rate studies,and recommendations for additional generating and transmission
facili ties.
Prepared flow analyses and equipment specifications,and supervised preparation of construction drawings and
installation of filter plant,pumping plant,and sewer system.
Designed laboratories and process system using I iquid metal for heat transfer,CAN EL Project.Nuclear Ai rcraft Program.
Participated in feasibility studies for various municipal,public authority,and private power systems.
1949 to 1952:
Louisiana State University,Baton Rouge,Louisiana.
Assistant Professor of HydrauliC Engineering.
1947 to 1949:
Aluminum Company ot America,Pittsburgh,Pennsylvania.
Hydrau I ic Design Engineer.Worked on struc tural and hyd raulic design of dams,penstocks,hyd roelectric power
plants,and appurtenances.
1/78
ENGINEERING COMPANY
RICHARD D.HARZA
President
Professional Engineer -Alaska,Arizona,District of Columbia,
Illinois,Indiana,Iowa,Michigan,Mississippi,Ohio,
Pennsylvania,Virginia,and Washington.
-
-
Degrees:
Languages:
Master of Science in Civil Engineering
Northwestern University,1947
Bachelor of Science in Mechanical Engineering
Northwestern University,1944
English,working knowledge of French
-
Civil Engineer -California
Structural Engineer -Illinois
Professional Societies:
American Institute of Consulting Engineers
American Society of Civil Engineers
American Water Resources Association (Past President)
Consulting Engineers Association of Illinois
Consulting Engineers Council
Illinois Society of Professional Engineers
National SocietY of Profes..sional Engineers
United States Commission on Large Dams (Past Chairman)
Har~a Engineering Company since 1947.
President,1977.
Vice-President,1953.
Director,Administrative,Financial,&Corporate Operations,1976 to date;Director,Management Group II,
U.S.A.Resources,1970-76;Civil Engineer,1947-53.
Experience Highlights:
Project Director of various projects including Deep Tunnel Plan,Lawrence Avenue Sewer System,and Lake
Michigan Airport appraisal study for the City of Chicago;Root,Fox,and Milwaukee River Watersheds
comprehensive plans for Southeastern Wisconsin Regional Planning Commission;Kinzua Pumped·Storage
Project,Pennsylvania;and numerous smaller projects and studies.
Responsible for preparation of proposals.negotiations,and contracts for engineering services.
Concrete inspector for 20-MW Petenwell Project,Wisconsin;and Investigations Engineer for Meric-Evros
Project in Greece and Turkey.
RICHARD D.HARZA
1946 to 1947:
Northwestern Unlversi ty,Civil Engineering Oepartmen t.
Instructor.
1945 to 1946:
Ensign,USN R,deck officer on escort aircraft carrier.
Technical Papers and Articles:
Written and presented various papers on practice of consulting engineering,hydroelectric projects,and
pumped-storage projects for ASCE proceedings and elsewhere.
6/77
ENGINEERING COMPANY
Professiopal Land Surveyor -Florida
Professional Engineer -Florida,Illinois,New Jersey,and New York
ROBERT D.HILLIARD
Assistant Head,Construction Management
Division
Head,Cost Estimating Department
Bachelor of Civil Engineering
Clarkson College of Technology,1948
Degree:
Professional Society:
American Society of Civil Engineers
Harza Engineering Company.1966-68.Since 1976.
Construction Management Division:Assistant Head,1978 to date;Head,Cost Estimating Department,1977 to date;
Senior Construction Engineer,1976;Office Engineer,1966-68.
Experience Highlights:
Division activities include preparation of contract documents,cost estimates,construction planning and scheduling,
construction inspection,contract administration,and technical procurement.
Project Manager during initial organization phases for construction management services for the $500 million
Mainstream Tunnel Project,Chicago,Illinois.
As Department Head,responsible for preparation of all construction cost estimates,evaluating bids on construction
contracts,and making recommendations for award.Prepared a detailed cost estimating procedure manual for
company use.Responsible for bid evaluation for the $1.2 billion Guri Dam Final Stage Project,Venezuela.
As Senior Construction Engineer,was involved in all aspects of construction planning,engineering inspection,
scheduling,and cost estimates for the construction phase of projects.
As Office Engineer,was responsible for all field office operations in connection wi th construction of the Seneca
(Kinzua)Pumped-Storage Plant,Pennsylvania,including contractual correspondence ilnd claims,payment estimates,
review of shop drawings,reports,schedules,and budgets.
1974 to 1976:
Gordon H.Ball,Inc.,McLean,Virginia.
Senior Estimator.Prepared bid estimates for heavy construction projects inclUding tunnel,dam,subway,and bridge
Jobs.Responsibilities included all phases of estimate from site investigation to bid preparation.
1974:
Morrison-Knudsen Company,Boise,Idaho.
Project Engineer.Duties included all project engineering functions on excavation of Washington,D.C.,subway tunnel
using a tunnel boring machine.
ROBERT D.HILLIARD
1970 to 1974:
Tlppetts-Abbett-McCarthy-Stratton,New York,New York.
Deputy Resident Engineer.Supervised and inspected construction;responSible for payment estimates,contractual
correspondence,claims,and change orders for the intakes,outlets,tunnels,and gate shafts of Tarbela Dam,Pakistan.
Features included four 45-foot diameter power and outlet tunnels total ing 10,000 feet in length,four 41'x 67'
gate shafts 350-feet deep,over six miles of small diameter tunnels and adits together With massive gated intake and
outlet structures.Total quantities included approximately 1.7 million cubic yards of concrete,500,000 cubic yards
of which was underground,and over one million cubic yards of underground excavation.
1968 to 1970:
Ebasco Services,Inc.,New York,New York.
Construction Engineer.Prepared design layouts for construction facilities including utilities,trestle (ormwork and
batch plant for Ludington,Michigan,purnped-storage plant.Supervised and Inspected construction of a 530-loot
double curvature arch dam and a 309-MW powerplant at Gokcekaya,Turkey.
1960 to 1966:
Wiggins,Kei th and Hill iard,Ft.Lauderdale,Florida.
Partner.ResponSible for all engineering work in an engineering and surveying firm,Including design and superviSion
of construction of streets,drainage,water and sewage treatment plants and systems,sea walls,groins,and docks.
1952 to 1959:
J.A.Jones Construct ion Company,Charlotte,North Carol ina.
Project Engineer.Assigned to the construction of the 500-loot rock fill Derbend i Khan Dam,I raq;the 120-foot
concrete gravity Green Lane Dam,Pennsylvania;and 12 miles of the Ohio Turnpike.
Cost Engineer on the Old Hickory Lock and Darn,Tennessee.
19!50 to 1952:
A.S.Wikstrom,Inc.,Skaneateles,New York.
Project Engineer.Work involved preparing bid estimates for various heavy construction railroad and highway
prOJects.
1948 to 1950:
New York City Board of Water Supply.
As3istant Civil Engineer.Survey Party Chief and Concrete Inspector on construction of the Mermnan Dam,
Lackawack,New York.
2/79
ENGINEERING COMPANY
ROBERT C.HUNDLEY
Department Head and
Pumped-Storage Specialist
Bachelor of Science in Civil Engineering
(Hydroelectric Option)
University of Illinois,1953
Degrees:
Harza Engineering Company 1953,1954-56,since 1960.
Department Head and Pumped-Storage Specialist,Power
Resources Division,1975 to date,Assistant to Chief Hydroelectric
Engineer,1973-75;Civil Design Engineer,Power PrOject Divisions,
1971-72;Hydroelectric Engineer,Planning Division,1960-70;
Junior Engineer,Civil Division,1954·56:Field Engineer,Box
Canyon ProJect,1953.
Experience Highlights:
Project Manager for major pumped-storage hydroelectnc projects including the 1 ,OOO-MW Mount Hope Project,
New Jersey,the 2,000·to 3,000-MW project in northern Illinois;the 500-MW Monte/uma Project,ArlLona,the
800-to 1,OOO-MW WisconSin Survey;and two site surveys for IllinoIs.Participated In the development of multi-
level,underground pumped storage.Made studies for five utilities including the Mount Hope PrOjf)c1 ,.Hld the
Northwest Illinois ProJect.
Participated in studies for the following pumped-storage hydroelectriC projects'the 2,000·MW Bluestone PrOJect,
West Virginia;the 2,100-MW Bath County ProJect,Virginia;the 500-MW Havasu Project,ArI1ond,Maryland sites,
the 328-MW Brookville ProJect,Indiana;the 125-to 525-MW Raystown and 380-MW Seneca ProJects,Pennsylvania,
the 500-to 2,OOO-MW Merrimac ProJect,WisconSin,Metropolitan Sanitary District of Chicago;and the Genesee River
Basin Project,New York.
Studies of conventional hydroelectriC power projects including 2067·MW Guri,VeneLuela;140-MW Plsayambo,
Ecuador;1200·MW Nez Perce-High Mountain Sheep;788.5-MW Priest Rapids and 831.3-MW Wanapum,Washington,
135-MW Cerron Grande,EI Salvador,and 120-MW Tavera-Bao-Lopez,DominiCeJn Republ ic.
Participated In preparation of license applications to FPC for Mount Hope,Bath County,MonteiUfrlcl,'Jrld Seneca
Pumped-Storage Projects;existing Deep Creek,Raystown and Warrior Ridge Projects for the Pennsylvania Electric
Company;the Priest Rapids ProJEct,and preparation of Form 6,Original Cost Statement,for the SeneciJ Project.
PartiCipated in river diversion studies for the Bath County Pumped-Storage PrOJect,clnd for Gurl,TarbeliJ Darn,
Priest Rapids,Wanapum and Derbendi Khan Hydroelectric Projects.
1956 to 1960:
-
Corbetta Construction Company,Chicago,Illinois.
Con st ruct ion Su peri n te nden t.
Expeditor,Cost Control,and Estimator.
Project Engineer.Field work included expediting subcontractors'and contractor's work.
ROBERT C.HUNDLEY
1953 to 1954:
Sewell and Sewell,Newport,Washington.(Leave of absence from Harza Engineering Company.I
Box Canyon Project.Responsible for inspection of powerstation construction.
1952 to 1953:
Illinois State Water Survey.
Instrument Man.Conducted silt survey of ponds and lakes in central Illinois while attending University of Illinois.
Technical Papers and Articles:
Lecturer:Short course on "Underground Construction and Underground Pumped-Storage Concept,"at the
University of Wisconsin,Milwaukee,1975.
,/79
Vice ?~2sident,Director of Planning
M.~.,Political Science,
'3er\:2Ie-::'T ,1955.
3.~.,?01i~ical Science,
Califcr;ti2
-
-
-
P~ic~:.ar~I '\18 v·is Di.!:"ector cf PJar.nin.cT at CQ2c1 :~II~Il.~-te lS
resFcnsijle ~or cC~9r2hensj.~Te city and regional pla~~in~~n=
2n"i=o~Tental ?lanniGg.
Be~ore joinin.g CE2:r~::1I.L I ,',fr.I'ley'se~\t2''5.for Sr~\lf::'.fee.!:"s ?.s
~,2searc~i ?.3sistant pro-:essor an(~COD;3u~=.:::.r~t '".liit.h th.'::?U:-t"20G.
of GO'!~~~f~e~tal ?ese2~c~2~d Ser t /ic2,.Uni~lersity 0f Oreson.
I~this positioIl te served concurr~~tly ~s 2 3t2~£CCDSU!t~~t
to the L23gue 8f Oregcn Cities.~is r2sears~an,~consulti~q
experie~c2 i~cluded s~~~ies in local 00~1€r~re~t cr~3~iz~~i2~~~s
operations,mu~icipal finance,?erso~nel a~~inistration,
l~w e~~crc~~e11t a<i!~i~istraticD,~unici9a1.la~f 2~~cit]an~
r~Jio2a~?la~nins.~~r.Ivey serV2~as ~r~iV2~sity ccnsultant
to cities and counties in Oregcn i~connection ~ith the
rre?ar~tic~of co~prehensive city ~nd r~sicnal 91ans anj
l~nd 1.)2e :ceculation.1:1 1955 ,'Jr.Ivey S2rvec 2,5 co~s\Jl:?.r:t co
the ~ri-ccunty Ad~Tisory Co~nitt2e on the p=o?csed Cr2gc~
JU.:1es ~[atiQnal Se2.s~c·r·~.:-ris a.s3iS{1!~e:rlt5 al.sc ir\cllJde(1 t;;e.
est2~~i3~~ent of county-~;ije ?la~~ing ~rOS~a:~s i~Coos,
Lincol~,and Tillar.ook Counties cn the Dreson coast,~~d tte
cl.e".7el()pment of cOrlp.r:-eh.2nsi\l2 ~la!1s rll:.T!ore t~a.n tt:'ient~y
citiss 2nd counties t~rouq~0~t t~e st2te,
'~J~-I\7~.V·join.e~C:~2>j ~-i=~L i:J 196~,:~e 32r\7S-};:,J~r ':I32';:-3 a.s
2ri:-:.ci?al CCI:sul t2..nt to the Sout.h2aster~~'~a.3~in?ton ?2;~.ion2~.1.
?lan~irg :o~~ission a~~t~2 Cle2rwater Valley (Idaho)~egicna:.
Planni~g COMrission,~~i-state ?rosra~for the cevelo~~ent c~
a coroprehensive regional plan ~or growth anticipatec fro~Lowe~
Granite Dan and slac~water ncvisation to the Port of Lewiston.
~r.Ivey later served as ccnsulti~g planner ~or a number of
cities arC.ccunl:i.~~s i~t!:e P2.ci£ic ~Tor·t~i~,,[est,C,~li':cr:-~ia c1r:'::
Alas%a.
It"'_1953 and l~7Q,2~1:c.I\J2Y itlas -r_he ~rincl9~:_cor1s1~11t~:1t t.8 t'-;e
Ci.ty of.?0rtJ.and fo.r the ?ortla!"ld DO'·l!'.t:C"\I~?la:-:,a ~3_::,or ;:-la.n::-:i=-:.::
rrogr~:~that cc;,bi~e~t~e ~2S0~rCGS of t~e City Pla:~~i~J
Depa::-t:"r.er:t,t~e Or8aC:l 2~c:t3 ~-~i0'~\12~T ~;i\"'i.3ic:iT 2~~_C C:-I2i'~fII~L.
}""~cr2 recen~:2ssig"nrr:ecJ.ts :La\T2 il!.cllJ~:1ecl t1Je 6irectj_':>!1 of a
RICHARD S.IVEY
major highway location project through ~etropolitan Portland
and the study of traffic i~pacts on inner-city neighborhoods
associated with the 0esign of a major freeway river crossing.
He has prepared or directed environmental iwpact studies for
a variety of projects in both urban and non-urban settin9s.
Since 1964,Mr.Ivey has served as planning advisor to the
Warm Springs Indian Reservation in Oregon and has participated
in planning and economic studies for other Indian reservations
in the Pacific Northwest.
In Alaska Mr.Ivey has recently had responsibility for community
impact studies in the Kenai Borough in connection with offshore
oil development.He served as a consultant to the O.S.Corps
of Engineers in connection with the community involvement
element of the Corps'water quality study in Anchorage.
Mr.Ivey has lived and traveled in Europe and Asia and has
served as a lecturer and visiting critic at several universities.
MEMBERSHIP IN ORGANIZATIONS
ADerican Institute of Certified Planners
American Society of Planning Officials
Orban Land Institute
ENGINEERING COMPANY
KHALID JAWED
Hydrologist
Master of Science in Civil Engineering
Hydrology and Water Resources Branch
Colorado State University,1973
Bachelor of Science in Civil Engineering
University of Punjab,Pakistan,1958
English,Urdu,and reading knowledge of Farsi.Languages:
Degrees:
Harza Engineering Company,1964-65;Since 1976.
Environmental Sciences and Hydrology Division:Hydrologist,1976 to date;
Planning Division:Hydrologist,1964-65.
Experience Highlights:
Performs hydrologic analyses including those for determi nation of spi Ilway design floods,flood and drought
frequency,derivation of unit hydrographs,reservoir operation,and ground-water movement and yields.Field
activities include design and installation of meteorological and hydrologic stations,stream gauging,and sediment
sampling and laboratory analysis.
Specific assignments included cross drainage studies for the Gotvand Irrigation Project,Iran;reservoir operations
studies for the Kajakai reservoir,Afghanistan;water supply and probable maximum precipdation studies for
the Jordan Valley Stage II Irrigation Project,Jordan;backwater analysis,and rainfall frequency analysis for the
Upper Morass Project,Jamaica;and design of automated remote hydrologic and meteorological networks for the
Guri Final Stage Project,Venezuela.
1973 to 1976:
Water and Power Development Authority (WAPDA),Lahore,Pakistan.
Senior Engineer.Responsibilities included compilation,interpretation and publication of hydrometeorological data
collected by WAPDA,computations of suspended sediment load transported by rivers,associated with Harza
Engineering Company International at Lahore,Pakistan for preparing report titled,"Appraisal of Flood Manage·
ment Systems in Pakistan,Volume I -Flood Forecasting and Flood Warning Systems,Volume II -Existing
Flood Control Structures and Recommendations for a Planning Program."
1971 to 1973:
Colorado State University,Fort Collins,Colorado.
Graduate Research Assistant.Research work included runoff-rainfall relations,unit hydrograph studies,multi-
variate analysis,and flood-frequency analysis.One month training in Hydrologic Engineering Center,Corps of
Engineers,U.S.Army,Davis,California.
KHALID JAWED
1965 to 1971;
Water and Power Development Authority (WAPDAl,Lahore,Pakistan.
Senior Engineer.Responsibilities included compilation,interpretation and publication of hydrometeorological
data collected by WAPDA,computation of suspended and hed load transported by river and canals.
1964 to 1965:
Harza Engineering Company,Chicago.Illinois.
Training In applied hydrology.Work Included rainfall-runoff relations,compulation of backwater profiles,
computations of maximum probable storm and flood;generation of streamflow records,and evapotranspira-
tion computations.
1960 to 1964:
Water und Power Development Authority (WAPDA),Lahore,Pakrstan.
Senior and Junior Engineer,respectively.ResponSibilities as a Senior Engrneer Included collection of basic data
for ground-water Investigations,study of changes In ground-water levels,analysis of aquifer-test data for trans-
missibility and specific Yield.
Duties as a Junior Engineer Included Instull"tlon,malntenilnce and operation of all instruments and related
structures reqUired for hydrometeorologlcal investigation,collection of hydraulic parameters for existing canal
systems in Pakistan,verification of Lacey regime canal formulae,collection and laboratory analysis of suspended
sediment and bed material samples.
1958 to 1959:
Punjab Irrigation and Power Department,Pakistan,
Sub-diVISional Orficer.Duties Included design of a small Irrigation scheme,and discharge observations on rivers
and cani.lls.
Technical Papers and Articles:
Responsible for the follOWing WAPDA publications
Annual Reports of RIVEn cHId Climatological Data of West Pakistan Rivers,1963 through 1970.
Sediment Appraisal of West Pakistan Rlver'S,1967,1969,1970 and January 1975.
Snow Surveys of West Pakistan,June 1969.
BasIc Data Releilse -Ground Water Levels In Bahawalpur Area,1964.
Instructions on Stredm Gauging and Sediment Sampling,April 1967.
InstructiOllS for River Gauge Observers,January 1967,
Co-Author for U.S.G.S.Water Supply Paper 1608-K,"Water Resources and Related Geology of 0,I.Khan
DIs tr"l,Pak Istan ,"wi th re Ference to aval1abll ity of ground water for development.
Procedures Followed for Flnali!.ing DIscharge,Sediment,Water Quality and Climatological Record,Surface
Water Hydrology PrOject,WAPDA,July 1974.
Master of Science TheSIS "Comparrson of Melhods of Derlvlllg Unit Hydrographs."
Special Study for M.S.'"A Study ot Relationship between Watershed Parameters and Peak Discharge."
Co-author for Colorado Sla te Un i versl ty Publication No.73 KJ-R R -E F34,"Deriving a Un it Hydrograph in the
Absence of Detailed Raliltilil Oat","June 1973,
4/77
ENGINEERING COMPANY
Registered Land Surveyor -Illinois and Michigan
Professional Engineer -Illinois,Michigan and New York
JAMES JAY KELLER
Head,Transmission and
Distribution Division
Bachelor of Science in General Engineering
University of Illinois,1953
English,knowledge of Italian,Portuguese
and Spanish
Degree:
Languages:
-
Professional Societies:
American Congress on Surveying and Mapping (former)
American Society of Civil Eng'meers
CIGRE -UHV/EHV Substations Working Group -23-07 (former)
I nstitute of Electrical and Electronics Engineers
I EEE Towers,Poles &Conductors Subcommittee
Chicago Chapter,IEEE/PES (Chairman)
Illinois Society of Registered Land Surveyors
Michigan Society of Professional Engineers (former)
Michigan Society of Registered Land Surveyors
Harza Engineering Company 1965-68;1973 to date.
Electrical Design Branch:Head,Transmission and Distribution Division,1976 to date,Head,Transmission and
Distribution Department,1973-76;Project and Field Engineer,Pakistan,1965-68.
Experience Highlights:
Responsible for all phases of transmission and distribution engineering.
Project Manager for TAVANI R EHV Transmission System,Iran.Project includes 800 kilometers of single circuit
transmission line over half of which passes through elevated mountainous terrain.Project also Includes four
400/230-kV,400-MVA substations.
Project Manager for extension of500-kV Transmission System,Guddu to Mullan and Lyallpur,Pakistan,330 miles
of single circuit I'me passing through desert area and crossing two major rivers.Project includes one 220-kV substation.
Field Engineer responsible for specifications,bid evaluations,and contract administration for supply and erection of 135
miles of 220-kV transmission lines and additions to one major thermal generating station switchyard and one major
switching station,West Pakistan.These additions included installation and commissioning of four 63.5-MVA,
220/132-kV power transformers,several 200 and 132-kV bays including additional bus,air bldSt circuit breakers
and associated control,metering and protection equipment.
Project Engineer on a new generating station of four 15-MVA gas turbines and associated substation and for supervising
other engineers in related construction management and office staff positions,West Pakistan.Served in advisory position
to the General Manager,Chief Engineers and the Chairman of a medium-sized electric utility in Asia.In addition,
trained and supervised foreign engineers and technical personnel.
JAMES JAY KELLER
1968 to 1973:
Commonwealth Associates,Inc.,Jackson,Michigan.
Substation Project Manager for special projecls including 345-kV substation design review for Taiwan Power Company,
establ ish ing criteria for substation bus design,and preparing proposals for substation,transmission,and distribution
work.Also provided technical back-up to Rio de Janeiro Office of Inter-America Consultants,Inc.
Resident Director of technical operations,Inter-America Consultants,Inc.,Rio de Janeiro,Brazil (subsidiary of
Commonwealth Associates),responsible for eng'lneering supervision and design of nearly 2,000 miles of 500,345,
and 230-kV transmission lines,two 345·kV,one 230-kV and three 500-kV substations.
Project Manager on 500 and 230-kV substations,Gulf States Utilities (Texas)and worked on Delmarva Power &
Light 500-kV/230 1300 MVA substation and preliminary studies for 345-kV switchyard at lhe Ohio Edison Bruce
Mansfield Plant,Pennsylvan ia.Also,part iCI pated in st udles and prel immary design work on the econom ic and
technical feasibility of 765-kV transmission systems.
1962 to 1965:
Miner and Miner International,Lahore,West Pakistan.
Electrical Engineer on design of 800 miles of 132 and 66·kV transmission line,and 500 miles of 11·kV distribution
lines.
1960 to 1962:
Commonwealth Associates,Inc.,Jackson,Michigan.
Transmission Project Engineer on 138 and 345-kV transmission lines in Illinois,OhiO and New York.
1955 to 1960:
George E.Snyder Associates,Jackson,Michigan.
Structural Engi neer and Head,Surveyi ng Department Responsibi lit ies included design development and testing
of aluminum alloy,modular distribution substation structures for 13.34.5 and 69-kV as well as small highway
bridges,and all surveying opemt ions of the firm.
1953 to 1955:
Commonwealth Associates,Inc.,Jackson,Michigan.
Associate Design Engineer on development of modular steel 69-kV substations and foundations,meeting National
Electric Manufact urers Associat ion requirements.Worked in the Architectural Division on ut i Ii ty service bui Idings,
and assisted in supervising a gas distribution mapping program.
1946 to 1953:
State of Illinois -Division of Waterways.
Rodman to party chief while attending University of illinois.
1944 to 1946:
US Army Signal Corps,Adak,Alaska.
Maintenance of A.F.R.S.Radio Station WXLB operated on 900 KC.
Technical Papers and Articles:
"An Investigation of Failures of 66 and 132-kV Transmission Lines West Pakistan,"1964.
"Designmg Transmission Lines for Corrosive Atmospheres,"1966.
"Ru ido Acustico Y Rad io I nterferencia E mitldos Por Li neas De Transm Ission Y Subestaciones De 500-kV,"co-au thor
with L.H.Luzuriaga and presented at Buenos Aires,Argentina during XXIII Semana De La Ingenieria Electrica
Y Electronica -13 al 17 Seliembre,7971.(IEEE Argentina Section).
4179
•DONALD J.KLFJEN
Education
B.S.,Civil Engineering,~/lontana State University,1971
Experience
Mr.Kleven joined CH2M HILL in 1979,prior to which he w~s
employed by Santa Fe Engineering Services,Inc.,as flowline
superintendent responsible for direct supervision of a quality
control/contract management group on a project consisting of
115 mi les of aboveground preinsulated crude oi I pipeline with
associated pipe supports in Sohio's operating oil field at Prud-
hoe Bay,Alaska.The flowl ine quality control/contract manage-
ment group consisted of 35 to 40 personnel,including disci-
pline supervisors,field engineers,e:lgiileering technicians,
and inspectors.
Prior to employment with Santa Fe Engineering Services,!nc.,
Mr.Kleven was employed by Brovvn and Root,Inc.,as pipeline
supervisor.Brown and Root,Inc.,was the general contractor
responsible fot-the engineel"ing and construction of the gather-
i ng system for the west na I f of the Prudhoe Say oj I fie!d.Re-
sponsibi I ities included contract management,quality control,
material flow,and field engineering r'elated to construction of
ail pipeiines and appurtenances in the above gathering system,
including approximately 120 miles of 6-inch line and 20 miles
of large-diameter p~ping.
Also,while employed by Brown and Root,!r:c.,f...~r.Kleven
was assigned as assistant superintendent of hydrostatic test-
ing for Arctic Constructors en the Alaska Pipel ine System,
Sections 5 and 6.
As a design engineer with Pipeline Technologist Inc.in
Houston,Texas,Mr.Kleven ',vas assigned as a staff engineer
on the following projects:
•El Paso Alaskan Gaslil1e Study
•Five-million-barrell crude oil storage tank farm for
Amerada Hess at Coli ins,M i ssi ssippi
K •Two-million-barrel crude oil storage tank farm fOI-
Amerada Hess at Ten Mi ie,Alabama
•Converting an existing 12-inch products line to a
crude ei I I ine from Port Arthur,Texas,to Longview,
Tex3s,ir,cll..Jding original pump st3tion,ir.termeciate
pumping Pac:i:ties,and termination storage faciiit!es
DONALD J.KLEVEN
Mr.Kleven has also worked for a water and sewer utilities con-
tractor as a field engineer.
Professiona I Registration
Alaska
Membership in Organizations
American Society of Civil Engineers
Chi Epsi Ion
Tau Beta Pi
ENGINEERING COMPANY
RICHARD F.KOKEN
Associate and
Chief Construction Engineer
Degree:Bachelor of Arts in English and Mathematics
Un iversity of Oregon,1936
Languages:English,speaking knowledge of Hindustani,
and working knowledge of German
Professional Engineer -Chartered Mechanical Engineer,India
Commission No.3587 from National Board
of Boiler and Pressure Vessel Inspectors -
American Society of Mechanical Engineers.
Professional Societies:
Institute of Engineers,India
Harza Engineering Company since 1969.
Associate,1978.
Ch ief Construction Engineer,1978 to date;Construction Management Division:Head,1974-78;
Senior Construction Engineer,1973-74;Resident Manager,Indonesia,1972-73;Construction Plant
Engineer and Acting Resident Manager,Indonesia,1969-72.
Experience Highlights:
Head,Construction Management Division.Division activities include preparation of contract documents,
cost esti mates,construction plann ing ,:lIld schedul ing,construction inspection,contract admi nistration,
and technical procurement.
Construction Plant Engineer,acting Re<;ident Manager,and Resident Manager respectively,of the
Irrigation Rehabilitation Project,Indonesi(J.Prepared master plans and assisted the Government of
Indonesia in all ma1ters related to construction equipment and management operations for the irrigation
of about 400,000 hectares (1 million (Jcres)of land.
1966 to 1969:
The Ralph M.Parsons Company,Los Angeles,California.
Project Manager on engineering projects in East Pakistan,Zambia,India,Argentina,Nicaragua,and
Tunisia.Responsible for fUlfilling contractural obligations,maintaining budgetary control and
schedu les,and coordinating business developments.
RICHARD F.KOKEN
1958 to 1966:
The Ralph M.Parsons Company,India.
Project Manager and Construction Plant and Equipment Advisor to Government of India.Responsible
for establishment and operation of heavy equipment training centers throughout India as well as
supervision of mechanic and operation specialists in training personnel for operation and maintenance
of large earthmoving and transportation equipment used in construction.
Construction Plant and Equipment Advisor involved in planning and layout for construction of multi-
purpose irrigation and power projects.
1955 to 1958:
Morrison Knudsen I nternational Company,South Korea.
Mechanical Superintendent.Responsible for rehabilitation of Hwachon Dam,involving repair of two
Hitachi 30,000 kVA generators,installation of one 30,000 kVA generator with Francis turbine,and
a three-phase 30,000 kW transformer.
1953 to 1955:
Government of Punjab.India.
Mechanical Supervisor for the Bhakra Nangal Project.Supervised rebuilding and installation of the
largest refngeration plant for aggregate cooling in Asia.
Member of the Construction Plant and Machinery Committee,Ministry of Irrigation and Power,
Government of India.
1948 to 1953:
U.S.Bureau of Reclamation,Grand Coulee Dam,Washington.
Equipment Supervisor.Responsible for maintenance,aquisition,assignment,and disposal of all mobile,
laboratory,engineering,repair shop,and special equipment utilized by 480 employees in the operation
and maintenance of the dam,waterways,powerhouses,pumping plants,switchyards.feeder canals,
and the equalizing reservoir.
Technical Publications:
"Lessons in Operation and Maintenance,Earthmoving Equipment."Instruction textbook published
in New Delhi,I ndia,funded by USAID.Richard F.Koken,author.
UTi ps on Operal ion,Earthmoving Equipment."Instruction manua I for operation of large machi nery,
published In New Delhi,India,funded by USAID.Richard F.Koken,author.
4/78
ENGINEERING COMPANY
Professional Societies:
JOHN J.KURUC
Plant Ecologist
American Associa tlon for the Advancement of Science
Ecological Society of America
Engl ish and reading knowledge of French and Spanish
Master of Science in Botany
University of North Carolina,Chapel Hill,1973
Bachelor of Science in Biology
Moravian College,Bethlehem,Pennsylvania,1966
Languages:
Degrees:
,...
Harza Engineering Company since 1976.
Environmental Sciences Division:Plant Ecologist,1976 to date.
Experience Highlights:
Responsibilities include evaluation of natural resources with particular emphasis on plant communities,
determination of botanical effects of projects,recommendations for mitigating actions,and preparation of botanical
sections of environmental reports.
Environmental Task Leader for a feasibility sludy evaluating alternative construction and operation designs for
increasing the generating capacity of five interconnected low-head hydropower stations on the St.Joseph River,
Michigan and I ndiana.Prepared a reconnaissance report on the environmental effects anticipated from the
modernization and expansion of a low-head hydropower station on the Susquehanna River,Pennsylvania.
Environmental Task Leader for the preparation of Exhibits R,S,V,and W of a FERC License Application for a
hydropower development on the Kootenai River,Montana.Additional duties included Acting Project Manager for
coordinating the entire license application to state and federal regulatory agencies,coordinating responses to agency
review comments,and participating in public presentations.
Developed a land reclamation plan for restoring an abandoned underground mine site and mine waste disposal area
in south-central Illinois into a regional wildlife and recreation natural resource.Developed a conceptual reclamation
plan for revegetating and providing alternative land uses for lands degraded by temporary flood water storage
behind the proposed Burlington Dam on the Upper Souris River,North Dakota.Also evaluated the potential for
increased mosquito production In stored flood waters and recommended appropriate mosquito control and
monitoring techniques.
Environmental Task Leader for a feasibility study of developing conventional hydropower generating capabilities at
three existing flooe-control dams on the Gauley,Elk,and Bluestone Rivers in West Virginia.The Bluestone River
study also included an environmental assessment and comparison of alternative upper pumped-storage reservoir sites.
JOHN J.KURUC
Active on several overseas projects,including environmental management programs for the Yacyreta Reservoir
development on the Rio Parana,Argentina and Paraguay.Programs Involved reestablishing and managing reservoir
margin forest stands for preserving selected riparian tree species and providing wildlife habitat and alternatives to
presen t land use options.Assisted In an economic analysIs of al ternative cropping patterns for an agricu I tural
development in the Upper Morass of the Black River,Jamaica.
Prepared an environmental assessment for a feasibility study of the irrigation development of 80,000 acres in
southwestern South Dakota.Assessment also included recommendations for enhancing wildlife habitat.
Prepared an environmental siting study for a proposed nuclear power station cooling reservoir on a tributary of the
Wabash River,I ndiana.Assessed and compared environmental impacts of al ternative above-ground pipell ne corridors
for cooling water supplier in north·central Illinois.
Participated in the preparation of the Draft Environmental Impact Statement for the rehabilitation of Lock and
Dam NO.1 on the Mississippi River,Minnesota.
Environmental Task Leader for an environmental siting study of a perched and underground pumped-storage
reservoir complex in north-central Illinois.
Evaluated the poten tial and prepared a developmental scheme for developing flood-compatible outdoor recreation
facilities along a 17-mile urbanized section of the Rock River floodway,Illinois.
1973 to 1976:
Environment Consultants,Inc.,Dallas,Texas.
Field ecologist in residence for a one-year detailed field survey of the flora and fauna of the islands of American
Samoa,Rose Atoll,and Swains Island.Designed,coordinated,and conducted field studies analyzing the Island's
plant communities,soil types,forest microclill}ates,wildlife habitats,and land-use patterns.
Participated in the preparation of numerous environmental assessment reports,including Environmental Impact
Statements for fossil fuel and nuclear power electrical generating plants and multipurpose reservoir developments in
Texas,North and South Carolina,Indiana,Ohio,and Kentucky.
Reviewed and evaluated land reclamation programs for restoring lignite surface strip mines,and assessed impacts of
mine-mouth power plant developments in eastern and southeastern Texas.
Recommended wildlife habitat enhancement and management programs for proposed resort developments In
New York,Texas,and Mexico.
1971 to 1973:
University of North Carolina,Chapel Hill,North Carolina.
Teaching and Research Assistant.Taught lab courses in general and economic botany,ecology,and plant taxonomy.
Conducted ecological field studies on barrier island plant communities and physiological ecology of individual species.
1968 to 1970:
U.S.Army.
5/79
I--JAR.ZA ENGINEERING COMPANY
WILLIAM R.LARSEN
Resident Manager and Geohydrologist
Zanja del Tigre Project,Argentina
Degrees:
Languages:
Master of Science in Hydrology
University of Nevada,1967
Bachelor of Science in Geology
University of Wisconsin,Milwaukee,1964
English,Spanish and working knowledge of
German
-
Professional Geologist -Cal ifornia
Professional Societies:
Association of Engineering Geologists
I nternational Water Resources Association
National Water Well Association
Harza Engineering Company since 1967.
Resident Manager and Geohydrologist,Argentina,1972 to date;Resident Manager and Geohydrologist,
Guatemala,1971-72;Water Resources Division;Geohydrologist,1967-71.
Experience Highlights:
Resident Manager and Geohydrologist for the Zanja del Tigre Project,Argentina.Supervised,administered,
and coordinated field and office investigations by Harza and local joint-venture team during the feasibility
studies for the $200 million storage dam and powerplant (450-MW)and the prefeasibility level studies of
downstream irrigation and settlement potential.Also supervised the $500,000 exploratory geologic
investigation of the dam site and reservoir area,which included core drilling,aq!Jifer permeability testin9,
geophysical surveying,and topographic mapping.
Resident Manager and Geohydrologist for the Northern Guatemala Study.Supervised and administered
groundwater,geologic,hydrologic,and agricultural field investigations for the prefeasibility studies of five
potential irrigation and hydroelectric projects in northern Guatemala.
Other groundwater and surface water resources assignments have included analysis and description of
exploratory investigations in selected areas of the Marun and Karun River Basins,Iran;estimates of
approximate groundwater yield for municipal,industrial and irrigation water supply in the St.Lawrence
River Basin,New York State;analysis of results of groundwater observation program to determine
possible effects of drainage canals in rice growing areas of lower Guinea;and analysis and evaluation of
historic hydrometeorological records for design storm and flood studies for Guri Dam,Venezuela.
...>lo..••
WI LLiAM R.LARSEN
Prepared and conducted model studies to determine design criteria for placement of granular fill in deep
water,evaluated storm and rainfall frequency data to determine volume of storage required to accommodate
runoff from maximum storm events,and supervised lacustrine-exploratory drilling and seismic surveys
for the Lake Michigan Airport studies.
1964 to 1967:
University of Nevada.
Graduate Student.under National Science Foundation Fellowship Tralneeship.
Desert Research Institute,University of Nevada.Graduate Research Assistant,Hydrology Section,one
year.
1964:
Illinois State Geological Survey;Urbana,Illinois.
Research Assistant,Groundwater Geology and Geophysical Exploration Section.
1960 to 1964:
University of Wisconsin in Racine,and University of Wisconsin,Milwaukee.
Undergraduate Student.
1957 to 1960:
U.S.Army
Classified Communication Work.
Technical Papers and Articles:
"Hydrologic and Geologic Aspects of Ground Water Recharge Along the Humboldt River Near Winnemucca:'
HUMBOLDT RIVER STUDIES,PROJECT REPORT NO.10,Center for Water Resources Research,Desert
Research Institute,University of Nevada System,Reno,July 1968.
"Ground Water Studies Chicagoland Deep Tunnel System:'(with I.S.Papadapoulos),G ROUN 0 WATE R,
Jour.,National Water Well Association,September,1969.
11/73
ENGINEERING COMPANY
BAUM K.LEE
Head,Surface-Water Hydrology Department
-Degrees:
Languages:
Ph.D.in Civil Engineering -Hydraulics
Colorado State Un'lversity,1973
Mas'rer of Science in Civil Engineering -Hydraulics
Co lorado State Un iversi ty,1969
Bachelor of Science in Civil Engineering
Seoul National University,Seoul,Korea,1963
English,Korean,and working knowledge of
Chinese,German,Japanese,and Spanish
-
-
Professional Societies:
American Geophysical Union
American Society of Civil Engineers
Korean Association of Hydrologic Sciences
Korean Society ot Civil Engineers
Harza Engineering Company since 1973.
Hydrology Division:Senior Hydrologist and Head,Surface-Water Hydrology Department,1978 to date.
Water Resources and Environmental Sciences Division:Water Resources Engineer,1973-78.
Experience Highlights:
Supervises,coordinates,and performs flood and storm analyses,sedimentation and erosion studies,stochastic
hydrology,mathematical modeling,and determination of water availability tor domestic and overseas projects,
Resident Hydrologist,Ecuador and Peru,for the Puyango-Tumbes Multipurpose Project to provide irrigation
water,hydroelectric power,flood control,and fisheries development,Prepared hydrology report,supervised
counterpart staffs for hydrologic studies,and trained local hydrologists.
Established a sed'lnlentation laboratory and a streamflow and sediment measurement program,and trained
local hydrologists,for the EI Nispero Hydroelectric Project,Honduras.
Served as Project Manager for the Receiving Water Study,Garrison Diversion Unit,North Dakota.Studied
effects of irrigation return flows on 22 water-quality parameters in 1 AOO miles of streams by using mathematical
models.
1967 to 1973:
Colorado Sta le University,
Graduate Research Assistant working for the U.S.Geological Survey.
Major research projects participated in were:dependent and independent variables in sediment transport;
resistance to Ilow I n alluvial channels;dispersion characteristics 0 r sand panicles in an alluvial stream:
stochasticity in transport and dispersion of sediment particles;and Hurst phenomena of dye dispersion In
BAUM K.LEE
natural rivers,These projects included general laboratory and field work in connection with the collection,
reduction,and analysis of sediment transport data uSing a large recirculating flume and a high-speed digital
compu (er,
1966 to 1967:
Korean Engineering Consultant Corporation,Seoul,Korea,
Group Leader,Hydrology Group,Water Resources Division.
SpecifiC duties included the superviSion of five Junior ciVil engineers,The major responsibility of the group
was hYdrologic and hydraulic analYSIS for the design report of a rTlultlpurpose dam to be built by the Korean
Govern men t.
1964 to 1966:
Ac\'lve military duty In the Eighth US Army Support Command as a KorCc)f)Augmentation 10 the United
States Army.
1963 to 1964:
Korean Engineering Consu Itant Corporation,Seou I,Korea,
Junior Civil Engineer,Hydrology Group,Water Resources DiVISion,
Responsibilities included unit hydrograph and flood analYSIS,statistical estimation of turbine discharge,and
Installation and subsequent analysis of rain and stream gauges for feasibility studies of hydroelectric power
rrOJects.
Technical Papers and Articles:
"Laboratory Study of an Alluvial Stream at One-Foot Depth,"M.S.Thesis,Civil Engineering Department,
Colorado State University,Fort Collrns,52 pp.,1969,
"A Review of Some StochastiC Models for Sediment Transport,"(unpublished),Civil Engineerrng Department,
Colorado State UniverSity,Fort Collins,80 pp.,1972,
"Stochastic CharacteristiCS of Particle Movement Over a Dune Bed,"With H,E.Jobson,International Symposium
on River Mechanics,Bangkok,Thailand,Proceedings Vol,1,15 pp"1973.
"StochastiC Analysis of Particle Movement Over a Dune Bed:'Ph.D.Dissertation,Colorado State University,
Fort Collins,216 pp.,1973.
"Stochastic Analys'ls of Dune Bed Profiles:'With H.E.Jobson,Journal of HydrauliCS DIVISion,ASCE 100 (HYT)-_.--
pp.849-867,1974
"Stochastic Analysis of Pdrticle Movement Over a Dune Bed:'With H.E.Jobson,U.S.Geological Survey Open
File Report,Bay St.LOUIS,Mississippi,221 pp.,1975.
"Stochastic Analysis of Dune Bed Profiles (Closure):'with H.E.Jobson,Journal of HydrauliCS DIVISion,ASCE----
101 (HY.11),pp.1445-1447,1975.
"StochastiC Analysis of Particle Movement Over a Dune Bed,"With H.E.Jobson,U.S.Geological Survey
Pro f·;ssional Paper 1040,Wash mgt on,D.C.,72 pp.,1977.
3/79
·ENGINEERING COMPANY
Professional Societies:
Professional Engineer -Illinois and Washington
KENNETH R.LEONARDSON
Department Head,
Power Projects Division
Bachelor of Science in Civil Engineering
University of Illinois -Hydraulics
Option,1954
Degrees:
,..
American Society of Civil Engineers
Harza Engineering Company 1970 to date;1957-1969;1954-1955.
Power Projects Division:Division Head,1978 to date;Department Head,1972-78;Section Head,1970-72 and
1967-69;Group Leader,1965-67;Civil Engineer,1957-64;Junior Engineer,1954-55.
Experience Highlights:
Project Manager for 140-MW hydroelectric plant on the Kootenai River in Montana,during the FERC License
Appl icat ion.
Project Manager for 210-MW Hrauneyjafoss hydroelectric project in Iceland for preparation of contract documents.
Prepared feasibility report on the expansion of the Cowlitz River Salmon Hatchery in Washington State.
Conducted studies for new intakes for the Dresden and Quad Cities nuclear power plants.
-
Engineer responsible for des'lgn and construction drawing preparation for third unit at Smith Mountain pumped-
storage hydroelectric plant,Virginia.
Project Manager for reconstructing an existing hydro plant to a "tube turbine"hydro-generating plant,Cornell,
Wisconsin,through feasibility study,design and engineering services during construction;and repairs to Upper
Occoquan Dam,Virginia,through preparation of contract and construction drawings.
Supervised the preparation of construction drawings for the spillway of the 200-meter high concrete arch Reza
Shah Kabir Dam,Iran;the morning glory spillway and outlet works for the Electric Lake Dam,Utah;and the
gravity water supply pipel"lne and trashrack for the River Mill Fishway Modifications,Oregon.
Prepared report on making waterfalls passable to fish for the Brule and Stewart Rivers,Minnesota.
Participated in th8 hydraulic and structural design for the Wanapum Dam fish passage facilities and supervised
the preparation of construction drawings for the right bank fish ladder at Wanapum Dam,Columbia River,
Washington.
,..
KENNETH R.LEONARDSON
1969 to 1970:
State of Washington,Department of Fisheries.
Duties included fish hatchery design and inspection of fish facilities throughout the state.
1964:
State of Wash ington,Department of Fisheries.
Hydraulic Engineer,Research Division.
1955 to 1957:
United States Army;Engineer Corps.
Topographic Surveyor in 320th Engineer Company.
4/78
GARY R.MASS
Concrete and Materials Engineer
-
-
Degree:
Additional
Studies:
ENGINEERING COMPANY
Bachelor of Science in Civil Engineering
South Dakota School of Mines &Technology,1964
California Department of Water Resources Concrete School,
Oroville,California,1964
California Department of Water Resources Soils School,
Sacramento,California,1965
U.S.Bureau of Reclamation Concrete Control School,
Denver,Colorado,1967
Portland Cement Association Soil-Cement School,
Skokie,Illinois,1968
California Department of Water Resources Radiological Operators School,
Tracy,California,1968
University of Wisconsin Extension Course on Deterioration and ReslOratlon of Concrete,
Madison,Wisconsin,1977
American Concrete Institute Seminar E-701,Aggregates for Concrete,
Philadelphia,Pennsylvania,1977
Portland Cement Association Course on Repair of Concrete Surfaces and Structures,
Skokie,Illinois,1977
-
Professional Engineer -California,Oregon,and Washington
Professional Societies:
American Concrete Institute (ACI)and Technical Commillees
ACI Committee 207 -Mass Concrete
ACI Committee 211 -Proportioning Concrete Mixes
ACI Committee 221 -Aggregates
ACI Committee 309 -Consolidation of Concrete
Harza Engineering Company since 1973.
Foundations and SOil Mechanics Division.Concrete and Materials Specialist,1973 to date.
Experience Highlights:
Advises on and participates in exploration and selection of aggregate sources and quarry locations,establishes
aggregate and concrete testing programs and evaluates results,prepares concrete specifications for large (mass)
concrete jobs and for small (structural)concrete applications;prepares concrete mix deSigns and supervises concrete
quality control testing programs for aggregates,cement,admixtures,and concrete mixtures;reviews contractors'
batchlng and mixing plants and aggregate plants for Job conditions and specification compliance;advises at job sites
concerning concrete production,placing procedures or methods,and construction problems;and advises on concrete
coatings,sealan ts,and other concrete materials_Performs these services for major pumped-storage and hydroelectric
proJects_
GARY R.MASS
1969 to 1973:
Kaiser Cement &Gypsum Corporation,Oakland,California.
Division Manager of Technical Services for Oregon,Washington,and Alaska.Responsible for field performance of
various types of portland cement produced and marketed by Kaiser and for compliance of these cements with
ASTM and various job speci fications.
Provided expertise on the chemical and physical properties of portland cement and their relationship to properties
of fresh and hardened concrete.Performed concrete testing for small,ready-mix concrete firms including aggregate
qual ity tests,laboratory mix designs,and tests on fresh concrete.I nvestigated reports of abnormal performance
and of defective concrete in which Kaiser cement was used.Provided consulting services on the application,
methods,and techniques employed or to be employed in the manufacture or use of portland cement concrete
and related materials.
1964 to 1969:
Department of Water Resources,State of California,Sacramento,California.
Assistant Materials Engineer.Responsible for supervising and coordinating the activities of four field laboratories
and a staff of 60.Programmed equipment and personnel requirements.Prepared monthly division reports on
earthwork and concrete quality requirements.Prepared monthly division reports on earthwork and concrete
qual ity control for twelve major contracts including summaries of construction materials used and of testing and
test results,and a statistical evaluation of soil compaction data and concrete compressive strengths.
Assigned to the Materials Section of the North San Joaquin Division,State Water Project,on earthwork and
concrete quality control for construction of 67 miles of the 1O,OOO-cfs,concrete-lined canal (California Aqueduct);
Delta Pumping Plant and Fish Facilities;and Del Valle,Bethany,and Clifton Court Forebay zoned,earthfill dams.
These projects involved placement of approximately 1 million cubic yards of portland cement concrete and 16.5
million cubic yards of compacted embankment.
Received on-the-job training at the central water resources laboratory in testing of soil,rock,and concrete materials
for the design and construction branches.
Engineer-in-training (6 months)in the concrete laboratory at the Oroville Dam.Performed field testing for quality
control of mass concrete,tunnel lining concrete,and structural concrete at the Oroville Dam,the Thermalito
Divers ion Dam,and rei ated featu res.
1963:
Department of Highways,State of Alaska,Juneau,Alaska.
Highway Technician.Performed office duties for the Construction Division in Nome,Alaska,including drafting,
calculating mass diagrams,and condensing survey notes.Worked as member of survey crew on preliminary design
and construction surveys.
3/79
ENGINEERING COMPANY
Professional Engineer --Illinois
Professional Societies:
American Society of Civil Engineers
RICHARD L.MEAGHER
Senior Associate and Acting Head,
Resources Development Branch
Bachelor of Science in Civil Engineenng
Un iversity of Notre Dame,1956
Degree:
Harza Engineering Company since 1956.
Senior Associate,1978.
-
Associate,1974.
Resources Development Branch:Acting Head,1978 to dale,Assistant Head,1977-78,HeCld,Power Resources
Division,1972·76;Planning and Civil Design Supervisor,1962-72;Structural Design Engineer,1958-62,Planning
Engineer,1956-58.
-
Experience Highlights:
Directs,supervises,and reviews the work of engineers,resource specialists,and drafters in planning the development
of land,water,and energy resources.Studies include master plans as well as appraisal,prefeasibil ity,and
feasibility of projects.Evaluations are based on engineering,environmental,economic,and financial considerations.
Project Manager for feasibility studies and FERC license application for the Brumley Gap and Powell Mountain
Pumped-Storage Projects in Virginia,each with an installed capacity of more than 3,000 MW.
Project Director for the following studies in Honduras:feasibility of EI Nlspero Hydroelectric Project.feasibility
of Ouimistan Valley Irrigation Proiect and Flood Control Master Plan for Sula Valley.
Project Director for appraisal of underground pumped·storage potential in Illinois.
-
Project Director for inventory of hydroelectric resources in eastern Honduras in which seven sites with a total
installed capacity of 1,700 MW were identi tied.
•Project Director for the prefeasibility study of a 450-MW hydroelectric development on the Rio Chimbo in Ecuador.
Project Manager for the study of the Palia River Basin in Southwest Colombia.The study involved Identification
of all sites having potential for construction,preliminary evaluation to determine the most favorable sites,and
selection of two sites for feasibility study.The potential total development would be about 3,000 MW.Feasibility
study for the initial project with installed capaci ty of 1,500 MW has been completed.
Project Manager for the prefeasibility study of the 3,OOO-MW Corpus Project on the Parana River,Argentina and
Paraguay.
RICHARD L.MEAGHER
Project Manager for two hydroelectric planning studies in Boliv·la.The first study recommended a plan of development
for a reach of the Rio Grande in Bolivia about 350 km long with a fall of about 1,000 meters.The study identified
nine potential hydroelectric project sites with a total installed capacity of 3,000 MW.The second study was for a
prefeasibility report to evaluate two small hydroelectric projects in southern Bol'lvia which could serve a community
with a population of about 30,000.
Project Manager for the feaSibility study of the HrauneYJafoss Project in Iceland which can serve expected growth
in industrial load.The project will have an installed capacity of 210 MW.
Project Manager during planning phase of the Rio Caroni hydroelectric development in Venezuela involving four
sites with a potential of about 15,000 MW.Supervised planning studies aimed at (1)appraising the overall
development and (2)determining the technical and economic feasibility of a program for staged expansion at
two sites which have been partially developed.
Project Manager for the feasibility phase of a major multipurpose river project in Iran,which includes the develop-
ment of 40,000 heetdres of agricultural land with an irrigation and drainage system,and the construction of a
200-m arch dam and a 1 ,OOO-MW power plant.
Senior Planning Engineer involved In preparation and supervision of planning studies for hydroelectric proJects.
Studies Included project layouts and estimates,power production,and economic analyses.Also supervised design
work and preparation of construction draWings for powerhouse,spillway,and diversion structures for hydroelectric
projects.
3/79
-
ENGINEERING COMPANY
ROLAND J.MESA
Senior Transmission and
Distribution Engineer
-Degrees:
Languages:
Bachelor of Science -Instituto Santiago,1948
(Santiago de Cuba,Cuba)
Surveying and Land Assessment -Institute Santiago,
1948 (Santiago de Cuba,Cuba)
M.S.in Electrical Engineering -Havana University,
1953 (Havana,Cuba)
Distribution Systems Training Course -C.C.E.Havana.
Cuba)'959
Fortran Programming (S.&L.Chicago,Illinois),'959
English and Spanish
-
-
Professional Engineer -Cuba,Illinois and Pennsylvania
Professional Societies:
Institute of Electrical and Electronics Engineers
Harza Engineering Company since 1973.
Transmission and Distribution:Senior T ransmissi on and Distribution Engineer,'973 to date.
Experience Highlights:
Senior Transmission and Distribution Engineer responsible for design engineering,economic evaluation of alternatives,
and consulting on national and international HV and EHV transmission projects of up to 765 kV.Consulting
design and engineering studies of distribution systems.
1964 to 1973:
Sargent &Lundy Engineers,Chicago,Illinois.
Project Engineer:Responsible for complete design of HV and EHV transmission lines,including:route selection,
wood H-frame and single pole structural design,computer application for line design.Application of steel tower,
steel pole and laminated wood structures.
Design Engineer:Design of transmission and industrial substations,including:line relays,switchgears,control and
instrumentation,specifications,material selection and economic evaluations.
Electrical Analyst Engineer:Relays and breakers,selestion and coordination for generating station units and
substations:switchgear selection,voltage drops,short circuit calculation.
1961 to 1964:
United Engineers &Constructors Inc.Philadelphia,Pennsylvania.
ROLAND J.MESA
Senior Designer of steam generating units.Responsibilities included checked and correlated physical and
schematic diagrams,including:control panels,switchgear data processing equipment.Development of basic
schematic diagrams and of single line diagrams.
1956 to 1961:
Compania Cubana de Electricidad,Havana,Cuba.
Engineering Department:Design of all phases of rural and urban Transmission and Distribution Lines.Sag
and tension calculation,tower spotting,selection of voltages,conductors,different types of structure,and
hardware.Complete structure design for wood H-frame and single pole. Planning for electrical power
distribution systems,including:voltage drops and loss calculations,use of capacitors and regulators.coordination
programs.Studies and forecast of load growth.Economic studies and evaluation of different plans for
improvement of distribution systems.Estimating and preparing budgets.Design of distribution substations.
Electrical Department:Division Engineer:Operation,maintenance,and improvement of transmission and
distribution systems.Responsible for job coordination of maintenance personnel.Dealing with labor union
in problems related with workers.Supervision of transmission lines construction.Construction supervision
of 110/33kV substations.
Right of Way:Head of the Right of Way and Surveying Department.
1950 to 1956:
Alvira Engineering Company,Consulting and Constructors Engineers,Havana,Cuba.
Design,construction,and surveying of rural and urban transmission and distribution Ii nes.
4/77
ENGINEERING COMPANY
EDGAR T.MOORE,JR.
Associate and Head,
Civil Design Branch III
Degrees:
Languages:
Master's Degree in Business Administration
University of Chicago,1969
Master of Science in Mechanics &Hydraulics
State University of Iowa,1958
Bachelor of Science in Civil Engineering
University of Illinois-graduated with
high honors,1957
English,Spanish and
working knowledge of Italian
-
Professional Engineer -District of Columbia,Illinois and Kentucky
Structural Engineer -District of Columbia and Illinois
Land Surveyor -Illinois
Professional Societies:
American ConcretE'Institute
American Society of Civil Engineers
Illinois Society of Professional Engineers;Chapter Officer 1962,1963,and 1964
National Society of Professional Engineers
Association of Engineerin.g Geologists
Harza Engineering Company since 1959.
Associate,1971.
Head of Civil Design Branch III,1978 to Date;Resident Chief Engineer of Harza de Venezuela,Caracas,1976·77.
Head,Power Projects Division II,1973-76;Resident Chief Engineer,Yacyreta-Apipe Project,Argentina,1972-73;
Head,Transportation Division,1971-72;Civil Design Branch,Department Head,1967-71;Section Head,1964-67;
Group Leader,1963-64;Designer,1959-63.
Experience Highlights:
Project Director and Project Manager of various low-head and high-head hydroelectric and mul ti-purpose projects
in South America,Caribbean,and Africa,for the preparation of feasibility reports,contract documents and
construction drawings,with considerable personal experience in making overall project layou ts including the
layout,dimensioning and design of the projects'features,including concrete gravity dams,power intakes,power
conduits and pens1'Ocks,powerhouses,spillways,outlet works,diversion works and river closures,and navigation locks.
Technical Papers and Articles:
Author of technical articles appearing in ASCE Civil Engineering magazine and ASCE Power Journal.
7/78
ENGINEERING COMPANY
Professional Engineer -Illinois
L.DOW NICHOL
Planning Engjnel~r
Degrees:
languages:
Bachelor of Science in Civil Engineering
University of Illinois,1953
Bachelor of Law
The George Washington University,1959
English and working knowledge of Spanish
-
-
Professional Societies:
American Society of Civi I Engi neers
Harza Engineering Company since 1960.
Resources Development Branch:Power Resources Division:Department Head,1975 to date;Resident Engineer,
Colombia,S.A.,1973-75;Department Head,1969·73;Planning Engineer,1965-69;Civil and Structural Engineer,
1963-65;Planning Division:Civil Engineer,1960-63.
Experience Highlights:
Conducted an appraisal of pumped-storage potential of the proposed Qattara Hydroelectric Development,
Egypt.
Resident Engineer for the 1700·MW Sogamoso Project,Colombia,S.A.thru the feasibility study.
Directed the optimization studies to select the generating capacitY and energy storage capacity of the 2100-MW
Bath County Pumped-Storage Project,Virginia.
Directed a program of map studies and field reconnaissance to identify potential pumped-storage project sites
in Maryland and West Virginia and compare them on the basis of economics and environmental factors.
Ca rried out portions of the layout studies for the underground power station for the 1710-MW Stony Creek
Pumped-Storage Project,Pennsylvania.
Directed studies of possible addition of from 500 to 4500·MW of pumped-storage generating capacity to the
basic storm overflow containment alternatives for the Chicago Tunnel and Reservoir Plan,Illinois.
Directed field reconnaissance of an undeveloped reach of 380 kilometers of river and preparation of prefeasibility
report of hydroelectric development,including preparation of screening program for evaluation of the various
sites,levels of development.and power markets for the Rio Grande Project,Bol ivia.
Prepared recommendations of legislative revisions as part of report on state policy regarding disposition of
obsolescent dams in Minnesota.
L.DOW NICHOL
Performed field reconnaissance and directed the preparation of appraisal report for two pumped-storage sites
in the Philippines,including preparation of computer program for study of reservoir use by eXisting project
jointly with pumped-storage project.
Directed the preparation of a report on remedial measures to preserve usefulness and appearance of a small scenic
and recreat ional pond used also for storm drainage retention;directed preparation of contract documents for the
Lake Ellyn renovation work,Illinois.
Assisted in preparation of report on valuation of an obsolescent hydroelectric project in connection wi th a
transfer of ownership,Lake Byllesby Dam,Minnesota.
Prepared computer program for generator reliability analysis of a small,hydrothermal system,using probability
method for the CE L System Expansion,EI Salvador.
Participated in the economic studies and report regarding installation of a supervisory control system for Central
Nebraska Publ ic Power and (rrigation District.
Participated in conceptual planning;appraisal studies of several power projects;and review of reports for the
Southern Bolivia Power Studies.
Drafted revised engineering services contract and negotiated with client in Addis Ababa for the 100-MW
Finchaa Project,Ethiopia.
Participated in the preparation of testimony and exhibits presented in the Federal Power Commission license
proceeding;analysis of testimony and exhibits of other parties for the Nez Perce and High Mountain Sheep
Projects,Oregon and Idaho.
Layouts and estimates for use in planning studies for the GUr"1 Project,Venezuela.
1959:
Merritt-Chapman and Scott Corporation,New York City,New York.
Office Engineer,Construction DiVision.
1956 to 1959:
John G.Loehler and Associates,Consulting Civil and Structural Engineers,Washington,D.C.and Kensington,
Maryland.
1953 to 1956:
Ensign and Lieutenant,J.G.,Civil Engineer Corps,U.S.Navy,Naval Gun Factory,Washington,D.C.and Naval
Ammunition Depot,Crane,Indiana.
11/76
ENGINEERING COMPANY
JAMES T.NI KOLAS
Vice President and
Head,Electrical Design Branch
Degrees:
Languages:
Master of Science in Electrical Engineering
Illinois Institute of Technology,1958
Bachelor of Science in Electrical and
Mechanical Engineering
Technical University of Athens,"Ethnikor
Metsovion Poly technion ,"Greece,1953
Engl ish and Greek
-
-
Professional Engineer -Illinois,Indiana,South Carolina,and Greece.
Professional Societies:
Eta Kappa Nu Association
Institute of Electncal and Electronics Engineers
Sigma Xi Association
Harza Engineering Company since 1959.
Vice President,1978.
Senior Associate,1976.
Associate,1970.
Head,Electrical Design Branch,1975 to date;Chief Electrical Design Engineer,1970 to 1975;Assistant Chief
Electrical Design Engineer,1967-70;Electrical Division:Department Head,Power Generati'on,1966-67;Section
Head,1962-66;Group Leader,1959-62_
Experience Highliglhts:
Start-up and field tests on 300-MW Mossyrock Project,Washington,USA and 80-MW Karadj PrOJect,Iran.
Supervised and participated in preparation of design criteria and specifications and construction drawings for
electrical equipment on the following hydroelectric projects:2700-MW Yacyreta-Apipe,Argentina and Paraguay;
180-MW San Lorenzo,EI Salvador;210·MW Hrauneyjafoss,Iceland;135-MW Cerron Grande,EI Salvador;
300-MW Mossyrock,Washington;1000-MW Reza Shah Kabir,Iran;100-MW Finchaa,Ethiopia;80-MW Rio
Lindo,Honduras;6-MW La Yeguada,Panama;80-MW Karadj Project,Iran;212-MW Angat Project,Philippines;
and for the five diesel plants,CEMAT Project,Brazil.
Supervised prepara tion of electrical designs,plans and specifications for Cowl i lz River Sal mon Hatchery,
Washington,and Conowingo Dam fish collection facilities,Maryland.
Project Director for electrical review for Prairie Island Nuclear Power Project,Minnesota;Assistant Project
Director on turbine,governor,and generator testing on Malpaso Project,Mexico.
Project Director for Duncan High·Voltage Substation,Jamaica.
JAMES T.NI KOlAS
Assistant Project Director for the CE L System Expansion Oriente Region and the Soyapango Gas
Turbine Plant,EI Salvador.
Project Manager for temporary repairs and Project Director for studies for permanent restoration,
contract documents,construction drawings,and engineering services during construction for the
restoration of the Santee Cooper powerhouse,South Carolina,which was damaged by fire.
1956 to 1959:
Vern E.Alden Company,Chicago,Illinois.
Group Leader,fossil fuel generating station design.
1954 to 1956:
Publ ic Power Corporation;Athens,Greece.
H.V.Substation Maintenance Engineer.
1953 to 1954:
Hellenic Electric Company;Athens,Greece.
Electrical Engineer.
Technical Papers and Articles:
IEEE paper C75-157-3,"Design Features of the Iranian 400 kV Transmission System."Co-Author.
1977 American Power Conference paper "Gas Insulated Switchgear Solves Difficult Problems at Hydroelectric
Plants,"Co-Author.
1977 American Power Conference paper "Optimal Power System Operation Analysis Techniques,"Co-Author.
1977 London/S(ockholm International Workshop on Instrumentation and Control 01 Water and Wastewater
Systems paper,"Control and Monitoring of a Unique Wastewater System,"Co-Author.
Unpublished thesis on "Electrostatic Unbalances of Double Circuit Transmission Lines."
8/78
-
ENGINEERING COMPANY
Professional Engineer -Idaho and Illinois
ROGER G.OECHSEL
Assistant Head,
Foundations and Soil Mechanics Division,
Domestic Projects-
Degree:Bachelor of Science in Civil Engineering
Northwestern University,1960
-
Structural Engineer -Illinois
Professional Societies:
American Society of Civil Engineers
National Society of Professional Engineers
Harza Engineering Company since 1960.
Foundations and Soil Mechanics Division:Assistant Head,Domestic Projects,1978 to date;Department Head,
1972-78;Section Head,1968-72;Foundations,Soil Mechanics and Geology Division;Group Leader,1965-68;
Foundation and Embankment Department·.Soils Engineer,1960-65.
Experience Highlights:
Project Director for Beker Industries waste pond.Project entails design of waste pond reservoir from compacted
gypsum for storage of fine mill tail"l(\gs.
Project Manager for the Tilden Tailings Project,Michigan.Project includes an iron ore tailings retention
reservoir and effluent treatment facilities.Work included feasibility study,exploration,design and construction.
Project Soils Engineer for the 2100-MW Bath County Pumped-Storage Project,Virginia,which includes two dams.
One dam 500 feet high and 2500 feet long;the other 150 feet high and 2500 feet long.
Project Manager for the Meigs Mine project,Ohio,which includes two conveyor systems,two water supply
dams and an ash retention dam,through field exploration,planning,design and resident engineering services
during construction.
Project Manager for the improvement of the Barton,Argo,Geddes and Superior Dams,Huron River,for the
City of Ann Arbor,Michigan;and for a feasibility study for the beautification of the Flint River,for the City
of Flint,Michigan.
Project Manager for the repair of barge docking facilities,Mcintosh,Alabama;and for a feasibility study on
a phosphate slurry retention reservoir,Joliet,Illinois,for Olin Corporation.
Project Manager for the renovation of Lake Ellyn,which consisted of deepening the lake,stabilizing the shore-
line,and providing a new pier and retaining wall for Glen Ellyn,III inois;and for a feasibil i ty study on the use
of a sanitary landfill for a food distribution center for the Metropolitan Food Center,Illinois.
ROGER G.OECHSEL
Planned and supervised field investigations and wrote reports concerning pond stability including recommendations
for remedial treatment and future pond development for the Olin Corporation,Joliet,Illinois,the Coastal Chemical
Corp.,Pascagul ia,Mississippi,and Oli n Corporation,Pasadena,Texas,waste disposal ponds.
Participated in foundation and embankment design,preparation of portions of contract documents
and certain design memos for the 40-MW Rio Lindo project,Honduras.
Resident Engineer for a foundation exploration program for the 380-MW Seneca pumped-storage
project,Pennsylvania.Also responsible for writing design memoranda and specifications for the
foundation and embankment portion of the project;the design for the contract documents and
portions of the construction drawings for the Upper Reservoir and Field Engineer during construction
of the Upper Reservoir.
1957 to 1960:
Hazelel and Erdal;Chicago,Illinois.
Co-op student from Northwestern University.Made design studies on the freeway system for the
State of Wisconsin.Worked as soils,concrete and pile inspector on the Illinois TOllroad.
6179
ENGINEERING COMPANY
Professional Geologist -California
RUSSELL A.PAIGE
Geologist
Degrees:
Languages:
Master 0 f SCience In Geology
University of Washington,1959
Bilchelor of Science in Geology
University of Alilska,1955
English and Spanish
-
Certified Engineering Geologist -California
Professional Societies:
Associiltion of Engineering Geologists
Geological Society of America (Fellowship awarded In May 1972)
Harza Engineering Company since 1972.
Geological DIvision:Senior Geologist and Department Head,'977 to date;Geologist,1972-77.
Experience Highlights:
Responsible for the supervision and review of all assigned project geologic studies,planning,estimating,and
supervision of exploration programs,preparation and review of reports,liaison with design and planning engineers;
preparation of conlract documents;and supervision and training of personnel.
Project experience as Department Head includes feasibili ty and design studies of the Nlspero Hydroelectric Project,
now in construction in Honduras;prefeaSlbility studies of the Rernolino Hydroelectric Project In Honduras,design
exploration and detailed studies ilt the San Lorenzo Hydroelectric Project,a large earthfill dam and generating
station now in construction in EI Salvador,Central America;prefeasibility studies at Brumley Gap and Powell
Mountain,Virginia,two pumped-storage projects equal in magnitude ilrld complexity to the Bath County Project.
Work and responSibilities on other prOjects have included regional and detailed site geologic mapping;planning,
estimating,and supervision of exploration progrilrns;core logging;water pressure testing:preparation of reports
and contract docurnents;contract administration,reconnaissance evaluation of dilm sites;and special studies of
construction materials.
Resident Geologist for the following proJects.Stony Creek feasibility studi(,s for a large pumped-storage project
in Pennsylvania;Bath County Pumped-Storage Proj8ct,Virginia,now under construction as the largest pumped-
storage project in the U.S.;P,1tia Hydroelectric Project,Colombia,South America,feasibility studies for a complex
project involving a 300-meter high rockfill dam,the Foothills Project,Colorado,involving design studies for a
265-foot high conc.rete arch darn;the Chimbo River Hydroelectric Project,Ecuador,including prefeasibi I ity
studies for regional i1nd detailed geologic conditions for many sites throughout the Chimbo River Basin;the
Uribante-Caparo Hydroelectric Project,Venezuela,inclUding feasibility studies of four large earthfill and rockfill
dams,several tunnels,and powerstations;and the SUlil Valley Flood Control ProJect,which involved the evaluation
of numerous damsites in northern Honduras.
RUSSELL A.PAIGE
1963 to 1972:
Polar Division,Naval Civil Engineering Laboratory,Port Hueneme,Cal ifornia.
Specialized in engineering geology problems of snow,ice and frozen ground as related to the location of camps,
roads,airfields,and other Naval facilities in the polar regions.Applied research included studies to determine
seasonal changes in the strength properties and bearing capacity of sea Ice for heavy cargo aircraft,docking areas,
floating platforms,and other sea ice structures.
1962 to 1963:
Haner,Ross,and Sporseen,Consulting Engineers,Portland,Oregon.
Engineering Geologist.Responsible for geologic mapping of three dam sites,foundation and geologic studies
for pipeline,canal,and irrigation projects.This work involved shallow-zone seismology,surveying,and
supervision of core drilling programs.
1959 to 1962:
Peter Kiewit Sons Company,Vancouver,Washington.
Engineering Geologist.Duties consisted of classifying material on large excavation projects and helping to
determine methods and costs of excavation.Shallow-zone seismology was extensively used in this work.
Other duties included searches for sand,gravel,jetty stone,and rip rap.
1957 to 1959:
Graduate School,University of Washington.
Summer 1958:
Bureau of Public Roads,Fairbanks,Alaska.
Assistant Engineer.Road route geology,soils and materials classification,search and selection of construction
material during road route location between Healy and McKinley Park and Eureka to Tanana,Alaska.Also
did field work for MSc thesis.
1955 to 1957:
U.S.Geological Survey,Engineering Geology Branch,College,Alaska.
Geologist.Duties consisted of geologic mapping,reports,and research on frost action and permafrost.
Technical Papers and Articles:
"Floor Foundation Stabilization in Permafrost al Barrow,Alaska."Proceedings,Tenth Annual Symposium
on Engineering Geology and Soils Engineering,University of Idaho,Moscow,Idaho,April 1972.
"Engineering Geology in the McMurdo Sound Region,Antarctica."Proceedings of the 1966 Annual Meeting,
Association of Engineering Geologists,October 1966,also the Bulletin of the A.E.G.,Vol.4,No.1,
January 1967.
"Two Examples of Applied Engineering Geology.Mosier,Oregon,and Petersburg,Alaska."Proceedings
of the 15th Alaskan Science Conference,University of Alaska,1964.
"Frost Heaving of Piles with an Example from Fairbanks,Alaska."U,S,Geological Survey Bull.1111-1,
1963 (co-author).
And numerous other technical papers.
2/79
ENGINEERING COMPANY
Professional Societi,es:
WILLIAM L.PARTRIDGE
Senior Sociologist/Anthropologist
Engl ish and Span ish
Doctor of Philosophy in Anthropology
University of Florida,1974
Master of Arts in Anthropology
University of Florida,1969
Bachelor of Arts in Anthropology
University of Florida,1966
Languages:
Degrees:
American Anthropological Association (Fellow)
American Ethnological Society
Council on Anthropology and Education
Current Anthropology (Associate)
Royal Anthropological Institute of Great Britain and Ireland (Fellow)
Society of Applied Anthropology (Fellow)
Southern Anthropological Association
Southwestern Anthropological Association
Harza Engineering Company since 1978.
Senior Sociologist/Anthropologist,Environmental Sciences Division,1978 to date.
Experience Highlights:
Responsible for evaluating the social and cultural opportunities and impacts of resource development prOJects,and for
planning programs to enhance benefits and minimize adverse effects.Supervise the planning and execution of socio-
economic surveys and treatment of resulting data.Plan or review resettlement programs [Q ensure that human values
are maintained in the course of project development.
1978:
National Science Foundation.
Co-principal investigator,"Mazatec Resettlement and Out-Migration,"field work in southeastern MexIco on the impact
of hydroelectric development.
1975 to 1978:
Ulliversity of SOUthern Cali fornia,Los Angeles.
Assistant Professor of Anthropology.Responsible for research in and teaching of Social Anthropology and Economic
Development in latin America.
1977 to 1978:
Pan American Health Organization.
Co-principal investigator and seminar leader,"Human Ecology and Health Impacts of the Aleman Dam,Papaloapan
River Basin,Mexico."
WILLIAM l.PARTRIDGE
1976 and 1977:
Pan American Health Organization,Mexico City.
Temporary advisor to the Center -lor Human Ecology and Health.
1974 to 1975:
University of Sou thern Cal ifornia.
Visiting Assistant Professor of Anthropology.Responsible for research in and teaching of History of American Indians
and Socia)Anthropology in Latin America.
1972 to 1974:
National Institute of Mental Health.
Predoctoral Research Fellow,field work in Colombia,South America.
1971 to 1972:
University of Florida.
Graduate Teaching Assistant,Department of Anthropology.Taught general anthropology course and conducted research
on economic development in Latin Amenca.
1969 to 1971:
University College,University of Florida.
Instructor.Social Sciences Department.
Books:
The Craft 0 Community Study,with Solon T.Kimball,University of Florida Press (in press).
Applied Anthropology ~America,co-edited with Elizabeth M Eddy,Columbia University Press,New York,1978.
The Hippie Ghetto.The Natural History ~~Subculture,Holt,Rinehart and Winston,New York,1973.
Technical Papers and Articles:
"The Papaloapan Dam and Resettlement Project,"with A.B.Brown and J.Nugent,in Involuntary Migration and
Resettlement,edited by T.Oliver-Smith and A.Hansen (in press).
"Banana County in the Wake of United Fruit:Social and Economic Linkages,"American Ethnologist (in press).
"An Interdisciplinary Evaluation of the Human Ecology and Health Impacts of the Aleman Dam,"with J.Nugent,
A.B.Brown and J.Rees,available from Center for Human Ecology and Health,Pan American Health Organization,
Havre 30,Mexico 1,D.F.Mexico,1978.
"Development 0-1 Applied Anthropology in America,"with Elizabeth M.Eddy,in Applied Anthropology 0 America,
edited by E.M.Eddy and W.L.Partridge,Columbia University Press,New York,pp.3-45,1978.
"Comment on Voluntary Associations as Adaptive Mechanisms,"in Curren t Anthropology 17 (1),p.41,1976.
"Food Exchange Networks in a Tropical Plantation Community,"paper presented at a symposium,Sou thern
Anthropological Society,Clearwater,1974.
12178
ENGINEERING COMPANY
KNUT S.PLATOU
Senior Construction Engineer
Degrees:
Languages:
Bachelor of Science in Civil Engineering
University of Washington,1957
Engineering Computer Application,Fortran
Continued Stud·les Program Diploma
University of Washington,1967
English,German,Norwegian and
knowledge of French
--
-
-
-
Professional Engineer -Washington
Professional Societies:
American Concrete Institute
American Society of Civil Engineers
Norwegian Society of Civil Engineers
United States Committee on Large Dams
Harza Engineering Company since 1972.
Construction Management Division:Senior Construction Engineer,1972 to date.
Experience Highlights:
Engaged in construction design,conceptual planning and facil ities analysis for the construction phase of
hydroelectric and irrigation projects.
Provided simi lar services to cl ients for projects designed by others.I mplemen ted computer simulation program
for haul road and equipment efficiency.Providing source data on construction materials and methods for
hydraulic structures.Researched state of the arts developments in flow induced vibrations.Researched and
developed buoyant materials for patent rights.Researched state of the arts developments of oil spill and
containment methods.
1969 to 1972:
Development and Resources Corporation,New York City,New York.
Sen ior Construction Engineer.Assigned to the Khuzestan I rrigation Project,I ran with overall supervision of
inspection of all civil,mechanical,and electrical construction contracts for major regulating dam,diversion dam,
and complete irrigation system.Responsibility included supervision of the checking of contractor's shop
drawings,making field changes,and recommending major adjustments in contract plans to meet
field conditions.
KNUT S.PLATOU
1965 to 1969:
Tacoma City Light,Tacoma,Washington.
Senior Office Engineer,Mossyrock Proiect with direct responsibility under Harza Engineering Company's
Resident Engineer to organize and supervise office procedures,quantity control,structural,mechan ical,
electrical coordination,checkout of contractor's and manufacturer's drawings.Instigated data processing for
quantity control and field engineering problems.
1964:
ETS Hokin Corporation,General Contractor,California.
South Fork American R'lver Project.Participated in design evaluation of four hydroelectric power plants to
establish design criteria to accommodate contractor furnished turbines and generators.Supervised drafting section.
1962 to 1964:
R.W.Beck and Associates,Seattle,Washington.
Senior Office E ngi neer,Packwood Hydroelectric Project.Provided field organizat ion and services relating to high
head plant with tunnels,pipelines and penstock features.
1962:
Vinnel Corporation,Alhambra,California.
Construction Engineer,Red Bluff Diversion Dam.
1957 to 1962:
L.E.Dixon,Arundel,Honkin Conkin Joint Ventures General Contractors,San Gabriel,California.
Construction Engineer on Rocky Reach 1st Stage Dam,Columbia River,Washington.Rocky Reach 2nd Stage
11-uni t Powerhouse and Niagara Falls 1O-un it Pumped-Storage Plant.
Assignmen ts in construction engineering areas of large scale hydroelectric projects,such as lif t sheets,form
design,plant layout,cofferdam deSign,quanti ties,esti mat lng,schedul ing,cost control,claims evaluation and
subcontractor coordination.
1945 to 1957:
Norwegian Navy,ElectriCian.
U.S.Army,Armored.Airplane mechanic.
Construction laborer,Alaska and Washington.
11/75
-ENGINEERING COMPANY
Professional Societies:
Professional Engineer -Alaska,British Columbia,California,Iowa,
New York,Quebec,Washington,Wisconsin
H.K.PRATT
Assistant to the Chief Engineer
Bachelor of Science in Civil Engineering
Un'lversity of Minnesota,1933
Degree:
American Society of Civil Engineers (Fellow and Life Member)
Past National Chairman,Hydraulics Division;Past Chairman,
Committee on Hydraulic Structures
Association of Professional Engineers of British Columbia
Canadian National Committee on Large Dams (Past Chairman)
Canadian Society of Civil Engineers
Engineering Institute of Canada
Harza Engineering Company since 1977.
Assistant to the Chief Engineer,1977 to date.
Experience Highl ights:
Broad review of design of major dam and hydroelectric projects.
1974 to 1977:
Lalonde,Girouard,Letendre &Associates,Ltd.,Montreal,Canada.
Advisor on design of portion of James Bay Hydroelectric Project,Quebec.
1965 to 1973:
British Columbia Hydro and Power Authority,Vancover,British Columbia.
Chief Engineer for four years.Also member of Board of Directors of International Power and Engineering Consultants.
Retired 1973.
Associate Chief Engineer and Manager,Engineering Division.Duties included supervising generation,transmission and
distribution of electricity throughout the Province.
Head,Hydroelectric Division of International Power and Engineering Consultants,wholly owned subsidiary of British
Columbia Hydro and Power Authority.Responsibilities included supervising design and construction insepction of
600 foot high earthfill dam and 2,400,000 kW underground powerhouse,Portage Mountain project,Peace River,
British Columbia.
H.K.PRATT
1963 to 1965:
R.W.Beck and Associates,Seattle,Washington.
Head,Design and Construction Department.Supervised West Coast design and construction activities of firm,
including a high head hydroelectric project and two earth dams.
1961 to 1963:
Stanley Engineering Company,Muscatine,Iowa.
Chief Civil Engineer.Directed foundation investigation,surveys and feasibility study of Mt.Coffee Hydroelectric
project,Liberia,West Africa.Also responsible for all civil engineering design for company.
1956 to 1961:
Bechtel Corporation,San Francisco,California.
Project Engineer.In charge of design for the Oroville-Wyandotte South Fork project,Feather River,California.
Irrigation project consisting of 7 dams,3 power plants,20 miles of tunnel and 21 miles of irrigation and power
canals.
1934 to 1956:
Corps of Engineers,United States Army.
Staff Hydraul ic Engineer,St.Lawrence River Joint Board of Engineers.Review and approval of project design
and construction of St.Lawrence Power and Seaway project,Ontario and New York.
Senior and Principal Engineer.Chief,Hydraulics and Reports Branch.SupeNised hydraulic design of Garrison Dam
and hydroelectric plant (400,000 kW).
Junior Engineer,Assistant Engineer,Associate Engineer and Engineer.Upper Mississippi Valley Division,St.Louis,
Missouri.Engineering studies on dams,locks,levees,channel improvements and hydroelectric plants.Economic
analyses and detailed hydraulic and hydrologic design studies.
Engineering-Aide.Maintenance and operation engineering studies,Upper Mississippi River Dams and Locks,St.Paul
District,Minnesota.
Construction inspector,Fort Peck Dam,Missouri River,Montana.
6/79
ENGINEERING COMPANY
Professional Societies:
Professional Engineer -Idaho and Illinois
RUSSELL W.REVELL
Senior Associate and
Chief Hydrologist
English and working knowledge of Spanish
Master of Science in Hydraulic Engineering
State University of Iowa,1941
Bachelor of Science in Civil Engineering
Oregon State University,1938
Degrees:
Languages:
American Geophysical Union
American Nuclear Society Working Group on Design Basis Flooding at Power Reactor Sites
American Society of Civil Engineers
Committee on Hydrometeorology,ASCE (1967-71;Chairman 1970-71)
Chairman,Task Committee on the Re-€valuation of the Adequacy of Spillways of Existing Dams,ASCE (1969-75)
American Water Resources Association (Charter Member)
International Water Resources Association
U.S.Committee on Large Dams of the International Commission on Large Darns
Western Snow Conference
Harza Engineering Company since 1956.
Senior Associate,1976.
Associate,1969.
Chief Hydro logist,1967 to da te,Hydrologist,1962-67;Resident Manager,1958-62;Office Engineer,Iraq,1956-58.
Experience Highlights:
Responsible for quality of all work relating to surface hydrology,hydrometeorology,and flood control.
Resident Manager for the Hydrologic Survey of the Mekong River Basin,Vietnam,Laos,Cambodia,and Thailand,
and for the Hydrological Survey of Iraq,Baghdad.
1953 to 1956:
U.S.Bureau of Reclamation,Columbia Basin Inter-Agency Committee;Portland,Oregon.Senior member of
Technical Staff of Water Management Sub-Committee and Secretary of Power Planning SUb-Committee.
1949 to 1953:
U.S.Bureau of Reclamation;Boise,Idaho;Hydrologist.
RUSSELL W.REVELL
1946 to 1948:
U.S.Geological Survey,Water Resources Division;Boise,Idaho.
Assistant and Associate Engineer.
1942 to 1945:
u.s.Navy.
Squadron Aviation Ordnance Officer.
1938 to 1942:
u.S.Geological Survey,Water Resources Division;Iowa City,Iowa,Washington,D.C.and Los Angeles,
California.
Junior and Assistant Engineer.
1938 to 1939:
State University of Iowa,Iowa City.
Research Assistant In charge of Ralston Creek Experimental Watershed.
Technical Papers and Articles:
"Re-evaluating Spillway Adequacy of EXlstin\j Dams,"Journal of the Hydraulics Division,American
Society of Civil Engineers,Vol.99,No.HY 2,February,1973 {Task Committee Chairman and
co-author).
Section 5 (Conveyance of Water in Natural Channels)HANDBOOK OF APPLIED HYDRAULICS,
Third Edition (Davis and Sorensen,Editor'S),McGraw-Hili Book Company.
''The Effect of Freeboard on Evaporation from a Class A Evaporation Pan,"Master's ThesIs,1941
"A Duration Curve Study of Willamette Valley Streams,"Undergraduate ThesIs,1938.
"Use of Statistics in Runoff Forecasting,"presented at Northwestern Regional Meeting of the American
Geophysical Un ion,1955.
"Experience with Water-Stage Servo-Manometer Gages In Southeast ASia."presented a t the Second I nter-
national Seminar on Field Methods and Equipment Used in Hydrology and Hydrometeorology,Bangkok,
Thailand,1961
B/78
ENGINEERING COMPANY
Professional Societies:
JOHN P.ROBINSON
Aquatic Ecologist/Fisheries Biologist
Degrees:
Languages:
Master of Science in Zoology
University of Wiscons'tn,1973
Bachelor of Science in Biochemistry
Michigan State University,1969
English and Spanish,reading knowledge of
Portuguese and Italian
-
American Fisheries Society
American Society of Ichthyologists and Herpetologists
Harza Engineering Company since 1976.
Environmental Sciences Division.Aquatic Ecologist/Fisheries Biologist,1976 to date.
Experience Highl ights:
Evaluated potential impacts on aquatic organisms,including migratory salmonids,of development alternatives for
additional generating capacity at five ex'lsting dams on the St.Joseph River,Michigan and Indiana.
Prepared detailed specifications for a two·year fisheries investigation program for the Vacyreta Hydroelectric Project,
Argentina and Paraguay.
Monitored field studies and prepared aquatic ecology sections of b.hibits S (impacts on fish and wildlife resources)
and W (environmental report)for Federal Energy Regulatory Commission license application for the Kootenai River
Hydroelectric ProJect,Montana.
Identified potential impacts on fish Clnd wildlife and on the esthetiCS and recreational use of the Missouri River for
upgrading the water supply intake for the City of Williston,North Dakota.
Identified potential effects of hydropower generation flows on tailwaters fisheries and water quality at existing
flood control dams 'In the Kanawha River Basin,West Virginia.
Studied aquatic plant conditions in Lake Vojoa,Honduras,to identify potential problems and their causes;
recommended prevention and control measures for lake nutrient cycles.
Made recommendations for optimum design 0 f the Lake Andes-Wagner I rrigation Project intake,Lake Francis Case
(Missouri River),South Dakota,to minimize adverse effects on aquatic organisms.
Performed environmental field stud'les and made recommendations for mitigation of potential adverse impacts of
the EI Nispero HydroelectriC Project,Honduras.
Identified potential impacts on fisheries and wetlands resources and on public health of the Quimistan Valley
Irrigation ProJect,Rio Chamelecon,and Sula Valley flood control works,Sula Valley Feasibility Studies and Ulua
Basin Master Plan,Honduras;recommended mitigation measures and long-range environmental planning programs
for the two watersheds.
JOHN P.ROBINSON
Identified design parameters,available biological data,and scope of aquatic studies required for compliance of an
Illinois cooling water intake with federal (Section 316b,PL 92-5001 and state requirements to minimize effects on
aquatic organisms.Compared impacts of alternative intake sites and water pipel ine rou tes on stream organisms.
Provided biological criteria for optimum design to minimize mortality of aquatic organisms for expansion of cooling
water Intake capacity at Com monwealth Edison Quad Cities and Dresden Nuclear Stations,III inois.
Assisted in evaluating riverine and reservoir fisheries data,and in making recommendations for further investigative
and fisheries management programs for the San Lorenzo Hydroelectric Project,Rio Lempa,EI Salvador.
Evaluated the human use of riverine and marine aquatic resources in the project study area based on data obtained
in Cairo,Alexandria,and Rome for the Qattara HydroelectriC Project,Egypt.
Evaluated the important freshwater shrimp and estuarine fishenes resources of the Lower Morass area for the Black
River Upper Morass Irrigation Project,Jamaica,based on field investigations and data from secondary sources;also
made recommendations for the conservation and management of aquatic resources in the Lower Morass.
1974 to 1976:
Smithsonian Institution/U.S.Peace Corps Environmental Program;Servicio de Recursos Pesqueros,Direccl<)n General
de Recursos Naturales,Mlnisterio de Agricultura y Ganaderia,EI Salvador,Central America.
Aquatic Biologist.Duties included planning and execution of fisheries and genrral biological surveys of major river
systems.Made recommendations on resource use and conservation and on fu ture Investigative programs,wi th
special emphasis on hydroelectric impoundments on the RIO Lempa.
1970 to 1973:
University of Wiscons'ln,Madison,Wisconsin.
Graduate Research.Responsible for all phases of coho salmon ultrasonic tracking program in Lake Michigan near
Point Beach Nuclear Plant,Wisconsin;marine tracking of sockeye salmon near Prince Rupert,B.C.,Canada;and a
study of nearshore spawning movements of white bass,Lake Mendota,Wisconsin.Attended a course on miniaturized
radiotelemetry systems and a marine research cruise,Cape Hatteras,North Carolina.
Technical Papers and Articles:
"Study of Spawning Migration of Coho Salmon (Oncorhynchus kisutch)in Lake Michigan Using Ultrasonic
Transmitters,"Master of Science Thesis (on file at Laboratory of Limnology,University of Wisconsin).
Three biological nver survey reports from the Servicio de Recursos Pesqueros,Direccion General de Recursos
Naturales,Mlnisterio de Agricultura y Ganaderia,Soyapango,EI Salvador,Central America,in Spanish.
2179
ENGINEERING COMPANY
Professional Societies:
Professional Engineer -Illinois
American Society of Civil Engineers
Bachelor of Science in Civil Engineering (Hydraulics)
Stanford Un 'Iversity,1963
English,working knowledge of Spanish and Indonesian.Languages:
Degree:
HERBERT E.SCHOELLER
Assistant Head,Water Resources Division
Harza Engineering Company since 1966.
Water Resources Division:Assistant Head,1977 to date;Head,Water Planning Department,1974-76:Planning
Engineer /Hyd rol ogist,East Java,1972-74;Water Resou rces Division:Hydrau lie Engineer,1970-72;Project
Hydrologist,Thailand,1968-70;Water Resources Division:Hydraulic Engineer,1966-68_
Experience Highlights:
Planning Engineer/Hydrologist,East Java,Indonesia_Major responsibility for producing a ieasibillty study for irrigating
10,000 hectares of land,including coordination of geological,soils,agro-economic,and water supply investigations and
designs for dam,diversion works,and conveyance facilities.Directed planning studies for selection of Irrigation systems
to be up-graded and hydrological studies for determining water requirements and available water supplies for development
of operational procedures for irrigating about 230,000 hectares,principally riceland_
-
Project Manager for hydrologic environment,pollution abatement,flood control,and urban drainage studies.
Hydrologist,Colombia,on short-term assignment for training local engineers in preparing estimates of water supply and
flood run-off for a screening study and feasibility study of potential hydroelectric development sites.
Planning Engineer /Hydrol ogist,East Java',for feasibility studies of rehabi I itation of an irrigation system serving abou t
230,000 hectares of cultivated riceland.
Project Hydrologist,Bangkok,Thailand,feasibility studies of the Upper Nam Mun and Nam Chi Rivers.The project
included studies for five storage reservoirs,two diversion dams,potential power generation and a distribution system
serving about 60,000 hectares of irrigated area,primarily riceland.
--Hydrologist,Guri Project,Venezuela,short-term assignment for hydro-meterological network review and reconnaissance
study of flood warning system.
Hydrologist,Guinea,West Africa,feasibility studies for reclamation of coastal ricelands.
1963 to 1966:
International Engineering Company,San Francisco,California.
Associate Engineer,Hydrologist.
HERBERT E.SCHOELLER
1956 to 1963:
U.S.Geologica!Survey,Denver,Colorado.
Hydraulic Engineer Technician.
Technical Papers and Articles
"Problems of Inflow Design Flood Determination In the TropICS,"(with Dr.R.A.C1arkl ASCE National Water
Resources Engmeenng Meeting,Memphis,Tennessee,1970.
-
ENGINEERING COMPANY
Professional Societies:
Professional Engineer -Illinois
JOHN A.SCOVILLE,JR.
Vice-President
Master of Science
Thayer School of Engineering,1955
Bachelor of Arts
Dartmouth College,1954
Degrees:
-
American Society of Civil Engineers
British Geotechnical Society
International SOCiety of Soil Mechanics and Foundation Engineers
International Water Resources Association
United States Committee on Large Darns
Harza Engineering Company since 1957.
Director,Harza Engineering Company International,1974.
Vice President,Harza Engineering Company,1968;Associate,1967.
Deputy Director,Professional Staff Operations and Chief Soil Mechanics and Foundations Engineer,1977 to
date;Director,Eastern Hemisphere Management Group,1976-77;Assistant Director,Eastern Hemisphere
Management Group,1973-76.Head,Special Services Branch,1968-73;Assistant to Vice President,1965-68.
Indus Basin Division:Department Head,1964-65;Acting Department Head,1962-64.Soil Mechanics and
Foundations Department:Section Head,1960-62;Senior Engineer,1957-60.
Experience Highlights:
Chief Soil Mechanics and Foundations Engineer responsible for review of complex problems in geotechnical
engineering,establishing basic concepts for geotechnical investigation and design,and advice during cunstruction
and post-construclion geotechnical monitoring of all projects.
Project Director of all the company's work in Iran,1972-77.This included the 500-MW puwer plant and
200-meter high concrete arch darn for the Reza Shah Kabir Project the 38,000 hectare Gotvand Irrigation
Project,and the 800-kilometers uf 400-kV Karlin transmission line and 4400-kV substations,through final
design and construct'lon;the 165-meter high rockfill Nader Shah Darn and the 55,500 hectare Behbehan
Irrigation Project,during design,,and the Electric Utility Management ProJect.
PrOject Director for the Jordan Valley Irrigation Project -Stage II (Jordan).Project involves a rockfill dam,
powerplants,an 11,000 hectare irrigation project and conversion of an additional 11,000 hectares from grcJvity
to sprinkler irrigation.
Project Director for Pakistan projects responsible for coordinating all technical and administralive actiVities of
the Chicago Office with client needs.
JOHN A.SCOVILLE,JR.
Supervised and participated In the review of design,plans,and specifications for the 3711-ft.high Mangla
earthlill dam,and the 420-11.high earth and rocklill Tarbela darn,Pakistan,and the 236-rneter high rockfill
Tachlen darn,Tolwan.
1955 to 1957:
U.S.Army Corps of Engineers.
Enlisted rank classified as Civil Engineering Specialist.
1955:
OhIO Oil Company.
Junior Structural Engineer.
Technical Papers and Articles:
"Mangla Main Spillway,DeSign Features f or Weak Foundations,"wllh P.Sherlock,and A.R.Borges,
published In transactions of 10th International Congress on Large Dams,1969.
9/78
ENGINEERING COMPANY
WILLIAM YING-JER SHIEH
Senior Associate and Head,
Structural Analysis and Design Division
-
Degrees:
Languages:
Doctor of Philosophy in Civil Engineering
Northwestern UniverSity,1968
Master of Science In CIvil Engineering
Lehigh University,1958
Bachelor of Science in Civil Engmeerlng
University of illinois,1956
English,Japanese,and Chinese
Professional Engineer -Illinois and California
Structural Engineer -III inols
Professional Societies:
American SOCiety of Civil Engineers
Fritz LaborCltory Research Engineering Society
Illinois Society of Professional Engineers
National Society of Professional Engineers
The United States Committee On Large Dams.
Member of Earthquake Committee
Member of Maintenance,Operation &Safety Committee
Harza Engineering Company since 1959.
Senior Associate,1978.
Associate,1974.
Head,Structural AnalYSIS and Design DiVision,1974 to date.Applied Engineenng-Mechililics Design Division
Assistant Head,1972·74;Head,Structural Department,1967-72,HeCld,Structural Section,1964-67;Structural
Engineer,1959·64.
Experience Highlights:
ResponSible for supervision,design,and analysis of hydrauliC structu res such as cone re Ie arch dClms,penstocks,
transmission towers,underground caverns,tunnel lining,and earth embankment ~tructures,tJnd for development
and appllcCltlon of electronic cornputCllion programs for static and dynamic analYSIS of StrUClUf8S 'JS(.J(lcr Ily in
usage of finite element methods.
Project Manager for the re·analysis of the San Dimas Dam and the Big DaltOn Darn,California,by using the
latest analytical method,and for designs for the 280·foot high thlll arch Strontia DiverSion Dam,Colorddo.
WILLIAM YING-JER SHIEH
Witnessing tower testing and reviewing tower designs for 115·kV transmission lines for the CE L System Expansion
Project,EI Salvador;for 230-kV transmission lines for the 100·MW Finchaa ProJect,Ethiopia;and for 400-kV
transmission I ines for the Karum EHV Transmission System,I ran.
Design of steel penstock for the 270·MW Cerron Grande Project,EI Salvador,and for the 2,067-MW Guri Project,
Venezuela.
Design of spillway training walls for the 2,067·MW Guri Project,Venezuela,and for spillway structures for the
Pearl River Project,Mississippi.
Earthquake analyses for Braidwood cooling pond embankment for a nuclear power plant,IllinOIS,for the 85-meter
high Cerron Grande fill dam,EI Salvador;and for the 95-meter high Guri earthfill dam and the 110-meter high
Guri rockfill dam,Venezuela.
Consultant to International Harvester Company,III inois,on usage of computer progr<lm for structural analyses
by finite element methods.
Design,analysis and review of model tests for the 200-meter high Reza Shah Kabir arch dam,Iran;for the 600-foot
high Mossyrock arch dam,Washington;and vibration study for the 210-foot high Smith Mountain arch darn,
Virginia.
1958 to 1959:
Vogt,Ivers &Associates,Cincinnati,Ohio.
Structural Engineer.
Technical Papers and Articles:
"Crown Cantilever AnalYSIS of Arch Dam,"With R.P.Wengler,Eighteenth Conference Bendix Users Exchange
Organization Committee on Civil Engineer Application,Chicago,Illinois,1960.
"Stress at the Base of Long Spillway and Other Cantilever Walls,"with O.C.Zienklewlcz and J A.Veltrop,
International Congress of Large Dams,1961.
Discussion of "AnalysIs of Circular Arches on Elastic Abutment,"ASCE Trans.,Vol.128,Part II,1963.
"Analysis of Plates by Finite Triangular Elements,"with S.L.Lee and R.S.Parmalle,Journal of Engineering----
Mechanic Division,ASCE,Vol.94,No.EM5,Proc.Paper 6176,October 1968.
"Application of Elasto-Plasticity of Rock Mechanics By Finite Element Method,"With L.E.Baker and R.Sandhu,
presented to the 11 th Symposium On Rock Mechanics,Berkeley,California,1969.
"Design of Mossyrock Arch Dam,"with R.P.Wengler,'published In Journal of The Power Division,ASCE,Vol.97,
No.POl,January 1971.
"Application of Elasto-Plastic AnalYSIS in Earth Structures,"with R.Sandhu,presented at ASCE,Memphis National
Water Resources Engineering Conference,January 1970.
"Stability and DynamiC Analyses of Cooling Tower,"with C.H.Yeh,presented at ASME-IEEE Joint Power
Generation Conference,Boston,Massachusetts,September 10 -14,1972.
"Safety Analysis of Concrete Dams Under Earthquake,"with C.H.Yeh,Proceedings of an International Symposium
on Criteria and Assumptions for Numerical Analysis of Dams,Swansea,U.K.,September 8·11,1975.
"Transient Seepage Analysis of Guri Earthfill Dam by Finite Element Method,"with Chi·Yuan Wei,and Z.Pruza,
presented at ASCE Spring Convention on The Use of Computers in Geotechnical Design and Construction,Pittsburgh,
Pennsylvania,April 24-28, 1978.
and numerous other tehnical papers.
1/79
ENGINEERING COMPANY
Professional Societies:
Registered Geologist -California
Certified Engineering Geologist -California
Bachelor of Arts in Geology
University of California,Berkeley,1958
Degree:
American Geological Institute
Association of Engineering Geologist
Theta Tau -Engineering Fraternity
U.S.Committee on Large Dams
JOHN O.SIMS
Engineering Geologist
-
-
Harza Engineering Company since 1974.
Geology Division:Department Head,1974 to date.
Experience Highlights:
Responsible for direction,review,and evaluation of geologic field and office studies and geologic reports carried
out for planning,design and during construction of reservoirs,dams,tunnels,powerhouses and appurtenant
structures.
Monitoring and general review of field work of resident geologist assigned to construction staff at Reza Shah
Kabir 200 meter high concrete arch dam in Iran.Coordinate and assist in evaluation of results of geohv.drologic
monitoring program during reservoir filling.
Participated in the feasibility studies and exploration for design of the Uribante-Caparo project in Venezuela
consisting of four embankment dams of height 120 meters and their associated tunnels,spillways,powerhouses
and regulatory works for this large multipurpose project.
-Supervision of field exploration and geologic studies for installation of permanent gated spillway in existing
Kajakai Dam project,Afghanistan.
-Responsible for planning of the design exploration drilling program and supervision of the geologic field studies
for the 4040-MW Yacyreta-Apipe Project,Argentina.
Responsible for geologic review of the reanalysis of the existing San Dimas and Big Dalton Dams,California for
seism ic risk.
-
Responsible for planning and supervision of the feasibility and design phase field exploration programs and related
office studies and reports for the Tavera-Bao and Tavera-Lopez Hydroelectric Projects,Dominican Republic.
JOHN Q.SIMS
1969 to 1974:
Tippetts·Abbett-McCarthy-Stratton,New York City,New York.
Principal Geologist for the Tarbela Dam Project,Pakistan.Responsible for design exploration and construction
geology for entire project,which included three dams (470,345,and 220 ft.high with a total of 186 million
cubic yards of earth and rockfill),powerhouse (2100-MW),five tunnels 145 ft.JD.l,two spillways (7 and 9 gates},
and numerous irrigation adits and canals.Responsible for evaluation of stability and reinforcement of cutslopes
up to 700 ft.high,foundation inspection and treatment for all structures,excavation characteristics and support
requirements for the large tunnels,classification of all earth and rock materials for use in civil works,and review
of foundation grouting requirements and results of grouting.Developed construction geologic mapping techniques
and trained staff of 30 Pakistani geologists to perform foundation inspection and mapping.
1968 to 1969:
State of California,Department of Water Resources,Palmdale,California.
Resident Geologist for Cedar Springs Dam and Tunnel.Responsible for foundation mapping,tunnel logging,and
dam foundation grouting program for 330 ft.high earth and rockfill structure,including supervision of grouting
inspectors.
1958 to 1968:
Sta te of Cal ifornia,Department of Water Resources,Oroville,Cal ifornia.
Resident Geologist for Oroville Dam and Underground Powerhouse Project.Responsible for geologic interpretation
and mapping for the relocation of 23 miles of major railroad from the reservoir through 5 long tunnels,relocation
of State highway over four major steel and concrete bridges,construction of the 770 ft.high,81 million cu.yd.
dam and two downstream dams,two large diversion tunnels,a 600-MW underground powerhouse and smaller
downstream powerhouse,large sp illway,and canals.Responsible for design exploration and construction geologic
mapping of all tunnels,dam foundations,and spillway foundation;review and inspection of rock bolting program,
initiation of a seismitron rock noise monitoring program,evaluation of grouting results,and compilation of final
geologic data reports on all features.
1954 to 1958:
University of California,Berkeley,California.
Student.
4/77
ENGINEERING COMPANY
Professional Engineer -Illinois and California
VIRENDRA SINGH
Geotechnical Engineer
-
Degrees:
Languages:
Master of Science in Civil Engineering
Illinois Institute of Technology,1974
Bachelor of Science in Civil Engineering
University of Roorkee, Roorkee,India,1967
English and Hindi
-
-
Professional Societies:
American Railway Engineers Association
American Society of Civil Engineers
illinois Society of Professional Engineers
Harza Engineering Company since 1977.
Foundations and Soil Mechanics Division.Geotechnical Engineer,1977 to date.
Experience Highlights:
Responsibilities include all phases of geotechnical work from feasibility stage through the construction of the project,
including preparation of design and contract documents,dam embankment stability analyses,and superviSion of
geotechnical and drafting personnel.
Responsible for preparation of construction drawings,quality control guidelines during construction,and Instrumentation
for the San Lorenzo HydroelectriC Project,EI Salvador.
Responsible for geotechnical aspects of Sula Valley Flood Control Project and Ouimistan Valley Irrigation Project,
both in Honduras.
Performed 211 ternate dam section design studies for a raisable rock fill dam,material usage and optim ization studies,
dam slope stability analyses,rock·cut slope stability analyses for spillway and appurtenant works,cost estimates,
evaluation of performance characteristics of foundation and embankment material,foundation treatment studies,
and site seismic studies for the Maqarin Hydroelectric Project,Jordan.
Conducted a stability analysis of an earthfill dam for static and pseudostatic conditions for the GUr"1 Hydroelectric
Project,Venezuela.
1973 to 1977:
Sargent &Lundy,Chicago,Illinois.
Senior Soils Engineer.Responsible for geotechnical work on four nuclear power plants and one fossil fuel plant.
Responsibilities ·Included supervision and direcflon of geotechnical personnel,project activity schedule,client/vendor
contact,preparation and review of geotechnical reports,safety analysis reports {NRC guidelines}and quality
assurance documents,surveillance,and evaluation of field activities.
VIRENDRA SINGH
1970 to 1973:
Chicago &Northwestern Railway Company,Chicago,Illinois.
Civil Engineer.Duties included surveillance of and maintenance programs for railway embankments and track
structures,and office and field engineering for the structures.
1967 to 1970:
v.Singh &Company,Ghazibad,India.
Engineer responsible for design of retaining structures and foundations,and construction management for sewer
line construction.
4/79
•THOMAS S.SMALL
Electrical Engineer
Education
B.S.E.E.,Electrical Engineering,University of Alaska,1969
B.S.E.S.,Engineering Science,University of Alaska,1968
Post-Baccalaureate Courses in Engineering Management,Project
Management,and Electrical Engineering
Experience
Mr.Sma III s recent work has been related to supplying the
energy needs of rural Alaska communities.Projects include
design and installation of a standby dual-fuel generator
system for Nome,design of distribution facilities to replace
those destroyed during a 1974 storm,and design and relocation
of high-pressure gas mains and water and sewer lines.
Pr ior to employment wi th CH 2M HI LL,Mr.Small was uti I ity
manager and city engineer for the City of Nome Joint Utility
System where he was responsible for preparing and admin-
istering the utilityls budget.Other duties included opera-
tional supervision of a 5-megawatt diesel powerplant,design
and maintenance of new distribution and transmission facilities,
and maintenance and planni ng for sewer and water faci I ities.
His responsibi [ities also included purchasing and supervising
installation of three diesel generator systems.
As an engineer with Peter Kiewit &Sons,Mr.Small worked
primari Iy as a uti Jity engi neer for heavy construction
projects.Responsibilities included takeoff,scheduling,
and relocation of telephone,electric,water and sewer
systems.
Mr.Small is a captain in the Alaska National Guard.He has
responsibi lity to support the communication needs of the
207th Arctic Recon Group.He has traveled to and worked
wi th natives in more than 30 vi I Jages over the past 3 years.
Professional Engineer Registration
Alaska
Membership in Organi zations
Institute of Electrical and Electronic Engineers
Northwest Publ ic Power Associa tion
Publications
1969,"Generation Facilities in the Tanana Valley,II thesis,
Un iversi ty of Alaska.
ENGINEERING COMPANY
Professional Engineer -Maryland and Nova Scotia
KENNETH E.SORENSEN
Vice-President and
Chief Planning Engineer
-
Degrees:Master of Science in Civil Engineering
University of Minnesota,1946
Bachelor of Science in Civil Engineering
University of Minnesota,'939
-
Civil Engineer -Arizona
Structural Engineer ~Minnesota
Professional Societies:
American Society of Civil Engineers
National Society of Professional Engineers
U.S.Committee on Large Dams
U.S.National Committee,World Energy Conference
Harza Engineering Company since 1946.
Director,1971;Vice-President,1963.
Principal Techn ical Advisor to the President,1977;Director of Overseas Operations,'976·77;Director of
Latin American Operations,1970-76;Head,Resources Development Branch,1967-70;Chief Planning
Engineer,1964;Head,Planning Department,1954-64;Structural Engineer,1946-54.
Harza Engineering Company International:Chairman,1977;President,1974-77;Director,1957.
Experience Highlights:
Responsible for most of the firm's appraisal,planning,and financing reports for the past 20 years.
Some of the major hydroelectric projects include:28,000·MW Inga Project on the Congo River;
1O,OO0-MW development of the Caroni River in Venezuela;4000-MW Yacyreta-Apipe Project on
the Parana River;2500-MW Priest Rapids~Wanapum development on the Columbia River;1000-MW
Reza Shah Kabir Project in Iran.Experience includes projects in more than 25 countries.
1942 to 1945:
U.S.Naval Construction Battalion.
Lt.(s.g.)CEC,U.S.N.R.active duty in Aleutian Islands ,Jnd Philippines.
1940 to 1942:
Panama Canal,Office Engineering Division.
Structu ral Engineer.
KENNETH E.SORENSEN
1939 to 1940:
Kimberly Clark Corporation;Kimberly,Wisconsin.
Maintenance Engineer.
Technical Papers and Articles:
"Graphical Solution of Hydraulic Problems,"ASCE Trans.Vol.118,'953,p.61.
"Economic Planning for Stage Development,"with Robert D.Jackson,ASCE Journal -Hydraulics
Division,September,1968,p.1231.
"Underground Reservoirs:Pumped-Storage of the Future?,"CIVIL ENGINEERING,March 1969.
"Reinforcing Steel for Penstock Wye Branches,"Journal of the Power Division,Proceedings of the
American Society of Civil Engineers,presented September 30 to October 4,1968.
"A Fourth Dimension for the Urban Environment,"Journal of the Urban Planning and Development
Division,ASCE,Vol.97,No.UP1,Proc. Paper 8064,April,1971,pp.91-104.
Co-Editor "HANDBOOK OF APPLIED HYDRAULICS"-Third Edition,1969.McGraw-Hili Book
Company,Calvin V.Davis,Editor-in-Chief.
"Pumped-Storage Tidal Power,"Tidal Power Proceedings,Halifax,Nova Scotia,Plenum Press,1972.
5/77
-
-
Date of Birth:
Citizenship:
Degrees:
Language:
Professional
Registrations:
Professional
Societies:
August 1977
to Date:
HARZA ENGINEERING COMPANY
PHILIP S.STOFFEY
Assistant Concrete and Materials Engineer
December 10,1944
U.S.A.
Master of Science in Geohydrology
1968,University of Nebraska
Bachelor of Science in Earth Science
1966,Eastern Kentucky University
Graduate Courses in Soil Mechanics
1974,Northwestern University
English
Professional Engineering Geologist,#E041,Oregon
Certified Professional Geological Scientist #3848,National
Certified Engineering Technician #046625,National
American Concrete Institute
Association of Engineering Geologists
North Dakota Geologists
Twin City Geologists
Harza Engineering Company,Chicago,Illinois.
Concrete and Materials Specialist.Foundations and
Soil Mechanics Division.Responsible for evaluation
of construction materials;preparation of specifications;
establishing field quality control programs,assisting
field forces on concrete and soils problems;preparation
of a field gUide to be used by soils engineers
during soils investigations.
Field assignments include supervision of rock drilling
and program for tunnels and concrete aggregate;
supervision of materials investigation for impervious
material for earth fill darn;and concrete engineer
for repair of spillway which used fiber reinforced
concrete,expoxy mortar and included large scale
industrial grinding.
Major projects worked on include:El Nispero Project,
Honduras,ENEE;Bath County Pumped-Storage Project,
Virginia Electric and Power Company;Reza Shah Kabir
Hydroelectric Project,Iran;Maqarin project,Jordan;
San Lorenzo Project,El Salvador;and Lock and Dam
No.I,Corps of Engineers,Minneapolis,Minnesota.
PHILIP S.STOFFEY -2-
Assistant Concrete and Materials Engineer
March 1977
to August 1977:
July 1976
to March 1977:
February 1970
to July 1976:
May 1970
to July 1972:
Soil Testing Services of North Dakota,Bismarck,
North Dakota.Office Manager.Responsibilities
included promotion,managing the office,and handling
operations in the field and laboratory.
Major projects included:Concrete testing for 400
kV Transmission Line for Commonwealth Associates;
testing of concrete aggregate supply sources from
various quarries throughout North Dakota for Concrete
Products Company,Huron,South Dakota.
Soil Testing Services of Minnesota,Minneapolis,
Minnesota.Senior Engineering Geologist.Responsible
for instrumentation including slope indicator,
pressure meter,Whitmore strain gauge,and laboratory
permeability tests.Responsible for soils and
geologic investigations including drilling operations
and reports;managed quality control department
including field soil compaction and concrete testing.
Major projects worked on included:Soils,concrete
and asphalt quality control for Litton Industries,
Sioux Falls,South Dakota;pressure meter testing,
Pillsbury Building,Minneapolis,Minnesota;transmission
pole foundations,Northern States Power,Minneapolis,
Minnesota;slope indicator and pore pressure tests
for Evelith Taconite Company,Hibbing,Minnesota.
Soil Testing Services,Inc.,Northbrook,Illinois.
Senior Engineering Geologist.Responsibilities
involved instrumentation including seismic,resistivity,
and vibration studies,direction of field drilling
operations;soil report studies;chief field engineer
on numerous quality control projects including
inspection of concrete,caissons,slurry walls,
piles and soil inspections.
Major projects included direction of drilling
operations and a resistivity study for cavities in
Arzew,Algeria for Pullman-Kellog;direct field
drilling operations for Canadian Gypsum near Hagersville,
Canada;direct drilling operations for an environmental
land reclamation project near Sparta,Illinois for
Consolidation Coal;seismic studies for Cleveland
Cliffs Mining Company,near Ishpeming,Michigan and
Corps of Engineers near Lemont,Illinois.
Responsible for quality control including concrete
pipe piles and concrete inspection for Social Security
PHILIP S.STOFFEY -3-
Assistant Concrete and Materials Engineer
May 1970
to July 1972:
(Continued)
August 1969
to February 1970:
July 1968
to August 1969:
January 1979
Building in Chicago,Illinois,and for all quality
control and inspection including caissons -rock and
hard pan/steel H-piles,slurry wall,and tie back
system,and concrete including normal,lightweight,
fly ash and expansive concrete at the Standard Oil
Building in Chicago,Illinois.
Novak,Dempsey and Associates,Des Plaines,Illinois.
Geologist.Responsibilities included quality control
and testing of concrete and asphalt;technician on
auger drill rig.
Texaco,Inc.,Midland,Texas.
Development and Exploration Geologist.Responsibilities
included the making of geologic maps and cross
sections for oil development and exploration in the
Palo Duro Basin,Texas.
ENGINEERING COMPANY
ARTHUR H.STUKEY
Engineering Geologist
Engl ish and basic knowledge of French and Span ish
Master of Science in Geology
University of New Mexico,1968
Bachelor of SCience in Geology
Tufts University,1964
Languages:
Degrees:
Professional Registrations:
Certified Professional Geological Scientist,No.3930 (APGS)
Engineering Geologist,No.E146,Oregon
Professional Societies:
American Association of Petroleum Geologists
Association of Engineering Geologists
Association of Professional Geological Scienlists
Geological Society of America
Harza Engineering Company in 1971 and since 1975.
Geology Division:Engineering Geologist,1975 to date;Field Geologist,1971.
Experience Highlights:
Conducts site and office evaluations of engineering geology related principally to construction of major hydroelectric
projects,including the following:
Tavera-Bao Project,Dominican Republic (1979 to date):Responsibilities include site and office geologic work
during construction phase of the 100-m high embankment dam and appurtenant structures;geologic review of
grouting and drainage program;and a regional study to determine maximum credible earthquake {MCE).
Responsible for final project geologic report.
-
Reza Shah Kabir ProJect,a 200-m high thin arch dam (1975-78).Resident Geologist (1975-77):Prepared
final project geologic reporl,and coordinated hydrogeologic portIon of operation and maintenance manual.Field
duties included surface and subsurface structural and stratigraphic mapping during construction of cutoff wall,
power tunnel stubs,and drainage galleries,revision of drainage curtain to accommodate geologic criteria;design
of cored check holes For grout curtain,evaluation of drainage during first filling of reservoir,remedial grouting
evaluations;rock slope stabilization;supervision of deep observation hole drilling and contract preparations;and
implementation of geohydrological monitoring program.
Conducted office studies for Ch icago T Llnnel and Reservol r Plan (T A RP).and provided geologiC fou nda lion mapping
for Cornell Hydroelectric Plant,Cornell,Wisconsin (1975).
Conducted site geologic investigations during exploration phase for the Stony Creek Pumped-Storage PrOject,
Pennsylvania (1971).Duties included core logging,pressure testing,and establishing stratigraphic correlations.
ARTHUR H.STUKEY
1970 to 1975:
Rutgers University,New Brunswick,New Jersey.
Graduate Student,Department of Geology.Worked Intermlt1ently during this period.as follows
Consultant,Rutgers Institute for Environmental Studies (August 1974 -January 1975).Geologist on rnultldlSClpllnar-y
team reviewing,evaluating,and surnmariLlng technical literature to prepare gUidelines for local urban planning agencies
lhroughou t New Jersey.
Consultant,Madison Township EnVironmental CommiSSion,New Jersey (JanudrY -June 1974).Compiled field and
file dala ot geologiC and hydrogeologic factors relevant to urban development south of New York City.Also responSible
for publiC presentation of data and representing CommiSSion In legal deposition.
Consultant,Rutgers Institute for Environmental Studlcs (August -December 1973).Collected geologiC and qround-
water data for land-use mapping study of glaCiated,carbonate terratn In northern New Jersey.
Staff Geologist,Oclmes and Moore,Consulting En\Jlneers,Cranford,Np,w Jersey (September 1972 \0 July 19731-
Primary assignment was 10 research Bnd write structural geology portion of PSAR for AtlantiC City,New Jersey,
Offshore Nuclear Generating StatIOn.Duties included map syntheSIS,literature research,and Iiltervlews With active
researchers;supervlstng construction and evaluation of gravity and magnetiC models of basement anomalies.and
offshore and onshore regional structural analysis tor an area enc.Josed by a 100-mile radiUS clrclec centered at the;SltC.
Field Geologist,Dames and Moore Uune -September 1971).Primary responslbllilies II1cluded "spilt-spoon"SOil
sampling,stratigraphic correlation,marine geophYSical survey evaluation.and regIOnal geologiC study for a subsurfacp,
fault Investigation near a nuclear site in Maryland COBS tal pl'lIn.
Graduclte Teaching ASSistant (September 1970 -June 1971).Taught fundamental geologiC pflnelples ill survey
course,and developed laboratory and field exercises for undergraduate structural geologv course.
1966 to 1970:
Texaco,Inc.,Midland,Texas.
Exploration GeOlogist,Permian BaSin of West Texas and New Mexico.Field responSibilities assOCiated with
exploration dfilling included sample and mud logglnq.selecting casing pOints.core pOilltS,and drill stem leSt
Intervals,and overseeing mechanical logging (gamma-neutron,electriC,and sonic well surveys).Office duties Involved
prospp,ct generation lItlll?ing subsurface geologiC mapping techniques,geophYSical coordination,dnd well log analYSIS,
lease-rental evaluations,and regional geologic mapping.
5/79
-
-
-
Date of Birth:
Ci tizenship:
Degree:
Language:
Professional
Society:
Professional
Registration:
July 1977
to Date:
December 1976
to June 1977:
HARZA ENGINEERING COMPANY
DAVID SULKOWSKI
Planning Engineer
September 2,1953
U.S.A.
Bachelor of Science in Civil Engineering
1975,Michigan Technological University
English
American Society of Civil Engineers (Associate
Member)
Engineer-in-Training -Michigan
Harza Engineering Company,Chicago,Illinois.
Engineer,Power Resources Division.Duties include
work on the preparation of studies and reports for
hydroelectric power,flood control,and related
projects.Specific assignments are as follows:
VEPCO Project:Project involved the development of
a computer program to simulate the weekly operation,
on an hourly basis,of the power system of the
Virginia Electric and Power Company.Main work
involved revisions to the computer program in order
to fully utilize the energy storage of the Bath
County Pumped-Storage project.Final work consisted
of preparing a user's guide for the computer program.
Harza Engineering company,Chicago,Illinois.
Holtwood Generation Expansion Study.Project
involved studies on expanding the existing Holtwood
hydroelectric plant located on the Lower Susquehanna
River for the Pennsylvania Power and Light Company.
Main work included:backwater computations on the
tailrace channel;evaluation of energy production
for the existing power plant and the various expansion
schemes;analysis of flashboard failures and their
effect on energy productionj quantity and cost
estimates;economic analysis of alternativesj and
report preparation.
Fairview Pipeline Project:Project involved laying
out the route of a 24-mile pipeline to supply make-
up water for Illinois Power Company's 2500-MW thermal
generating plant.Main work included layout of
pipeline profiles,studies on economic pipe size
diameter,and cost estimates.
DAVID SULKOWSKI
Planning Engineer
June 1975
to November 1976:
May 1974
to September 1974:
October 1977
-2-
Harza Engineering Company,Chicago,Illinois.
Burlington Dam -Souris River Flood Control Project.
Interior drainage studies performed for the U.S.
Army Corps of Engineers on several communities along
the Souris River near Minot,North Dakota.Main
work included:initial compilation of data;
preliminary layout of alternatives;evalution of
hydrologic parameters for use in computing rainfall
runoff hydrographs and estimating streamflows;
layout and preliminary design of selected alternative;
hydraulic design of storm sewers,drainage conduits
and diversion structures;storm routings;determination
of pumping requirements -pump selection and operation;
use of computer programs developed by the Corps for
hydraulic computations;preparation of detailed cost
estimates;and report preparation.
San Lorenzo Project,El Salvador.Work involved
computations on river diversion;excavation,darn
fill,and concrete quantities;construction schedules;
and studies of road relocation in reservoir area.Also
performed work for the Land Resources Division,
including computations on earthwork,concrete quantities,
channel depths and sump design for channel lift
station.
Landsco Design,Redford,Michigan.
Draftsman.Responsibilities included interpreting
client's blueprints in preparing picture process
sheets for the 1976 Pontiac 4 and 6 cylinder engine
block,updating tool layout sheets,and detailing of
machine layouts.
-
-
ENGINEERING COMPANY
Professional Societies:
JAMES H.THRALL
Head.Ecological Sciences Department
-Degrees:
Languages:
Doctor of Philosophy in Biological SCience
Illinois State UniverSity,1972
Master of Science In Biological Science
St.Mary's College,1967
Bachelor of Science in Biology
S1.Mary's College,1964
English,Spanish,and French (readi ng knowledge)
-
-
American Society of Icthyologists and Herpetologists
International Society for Tropical Ecology
North American Benthologlcal Society
Harza Engineering Company since 1974.
Environmental Sciences Division:Aquatic Ecologist,1974 to date.
Experience Highlights:
Supervises aquatic and terrestrial resource assessments and ecological im[)aCI analyses for both domestiC and overseas
prOJects.Designs and supervises basIc fisheries Investigations,Including biological and socioeconomic field studies.
Project Manager for both environmental and engineering/agricultural proj8cts.Provides expert witness testimony to
governmental and International agenCies.
ProJect Manager for the International Puyango·Turnbes Irrigation Development PrOject (up to 140,000 hectares of
Irngatlon development in Peru and Ecuador).Coordinated work of engineers,agronomists,economists clnd b'lologists,
and supervised the preparation of a final report,in Spanish.
Environmental coordinator responsible for the preparation of an environmental asscsslnent report for the 80,000-ilcre
Lake Andes Irrigation Project in eastern South Dakota.Work included assessment of prOject Impacts on terrestnal,
wetland and aquatic habitats,development of recommendations for protecting ,md enhancing wildlife,hsheries and
recreation resources,as well as recommendations concernll1g necessary steps for com~llancc With local,state,and
federal regu la tory guidel i nes.
Project Manager for the review study of the International Joi nt Com mission 's re~ort on the Gar rison Diversion Uni t
irrigation project in North Dakota.Prepared a review report and presented expert witness testimony before the
International JOint Commission.
Supervised the preparation of a report on the riverine ecosystems to be affected by the Garrison DiverSion Unit,as
part of a study done for the Bureau of Reclamation.
Designed and supervised a year-long basic fisheries investigation in the Rio Lempa,EI Salvador,as part of the
feasibility studies of the San Lorenzo Hydroelectric ProJect.Work lI1c1uded biological,water quality and
socioeconomic field stUdies.
JAMES H.THRALL
Performed fisheries assessments for hydroelectric develnpment projects in Venezuela,Guyana,and Colombia.
1972 to 1974:
Peace Corps -Smithsonian I nstitute Environmental Program.
Worked with the Instituto de Desarrollo de Los Recursos Naturales Renovables (INDERENA)in Colombia,South
America.Engaged in studies of the sabaleta,Brycon henni,a freshwater fish,including its life history,basic ecological
investigations,as well as studies related to the development of this species for fish culture.Limnological studies on a
newly formed reservoir of EI Penal and on the Porce River,Colombia.Advisor to the staff of INDERENA (a conservation
agency of the Colombia government)in the planning of fish culture stations and future fisheries research projects.
Taught an intensive,one-week course in aquatic ecology,attended by all INDERENA fisheries biologists.
1967 to 1972:
Illinois State University,Bloomington,Illinois.
National Science Foundation Research Fellow and Teaching Assistant in the Department of Biological Sciences.
Doctoral dissertation research on the aquatic ecology of larva!amphibians.
1966 to 1967:
S1.Mary's College,Winona,Minnesota.
Master's candidate and teaching assistant.Master's thesis research on feeding and digestive physiology of freshwater
mussels.
1964 to 1966:
Institute of Medical Technology,Minneapolis,Minnesota.
Instructor in anatomy and physiology.
Technical Papers and Articles:
"Alimento y Alimentacion de la Sabaleta (Characidae:Brycon henni)en el Rio Porce con Observaciones Sobre
Alimentacion in Cautividad"Instituto de Desarrollo de Los Recursos Naturales Renovables.Medellin,Antioquia,
Colombia,1973.
"Peces de la AI ta y Media Cuacha,Algunos Posibil idades Para Pisicultura."I nstitu to de Desarrollo de Los Recursos
Naturales Renovables,Medellin,Antioquia,Colombia,1973.
"Excavation of Pits by Juvenile Rana catesbeiana,"Copeia,1971,pp.751-752.
"An Albino DeKay's Snake (Storeria dekayi wrightorum Trapido)from Central Illinois."Transactions of the Illinois
State Academy of Science,1972,Vol.64,No.4,P.400.
5/79
-
-
-
.....
-
Date of Birth:
Citizenship:
Degrees:
Languages:
Professional
Registrations:
Professional
Societies:
February 1978
to Date:
HARZA ENGINEERING COMPANY
ALEXIS C.VIRCOL
Power Planning Engineer
September IS,1935
Permanent Resident of U.S.A.
Master of Engineering in Hydroelectrical Engineering
1958,Polytechnical Institute of Bucharest,
Bucharest,Rumania
Graduate Courses in Applied Fluid Mechanics
1977-1979,Northwestern University,
Evanston.Illinois
English,French and Rumanian;reading ability
in Spanish
Professional Engineer -Illinois (1977)
and Rumania (1966)
American Society of Civil Engineers
International Water Resources Association
Harza Engineering Company.Chicago,Illinois.
Power Planning Engineer.Power Resources Division.
Assignments have included:economic evaluations of
potential hydro-power alternatives at various
existing multi-purpose dams in the Kanawha River
Basin,West Virginia (both normalized cost and life-
cycle cost analyses);design and cost estimates of
spillways,fuse-plugs.lower level outlets for
various upper and lower reservoirs included as
alternatives in Brumley Gap Pumped-Storage Project,
Virginia;economic evaluation of the thermal alternatives
(oil-fired and woodchip-fired steam-electric plants)
for a feasibility study of a hydro-power plant to be
built at Itapeuara,Brazil.as well as present worth
comparisons of equivalent alternative gravity dam
schemes for the same project;economic assessment
and comparison of various current and future technologies
to satisfy future peak demands in the American
Electric Power System for the U.S.Army Corps of
Engineers;estimation of contractor's liquidated
damages for late start-up of the Yacyreta Project in
Argentina;evaluation of hydroelectric potential at
the existing projects in the Ohio River Basin
(mainly flood-control and recreation dams plus locks
and dams);evaluation of powerplant extensions at
the Priest Rapids and Wanapum Projects on the Columbia
River.WashingtonA
ALEXIS C.VIRCOL
Power Planning Engineer
-2-
February 1976
to February 1978:
S ep tember 1963
to October 1975:
May 1959
to September 1963:
Harza Engineering Company,Chicago,Illinois.
Planning Engineer.Resources Development Branch.
Assignments have included:Design and cost estimate
of a diffuser structure at D.fi.Mitchell Power
Station in Indiana;hydrologic analyses for the Guri
Hydroelectric Power Project,Venezuela;determination
of spillway and outlet design flooas for the multi-
purpose (irrigation,water supply,flood control)
Kajakai Project in Afghanistan;determination of
water supply availability and estimated drainage
design discharges for the Black River Upper Morass
Project,Jamaica;determination of hydraulic elements
(water surface long-profiles and dike-elevations)
for agricultural flood control in Jamaica,Upper
Morass Project;water and salt budget analyses,
determination of design floods for hydraulic structures,
and prediction of lake level for Great Salt Lake,
Utah;water availability studies,PMP and PMF
analyses,and irrigation requirements for the Yarmouk
River Project,Jordan;participation in determination
of spillway and interconnection system design flood
for the multi-purpose (irrigation,power,flood
control)project at Tavera-Baa,Dominican Republic;
hydraulic analyses for the surface water-control
plan at the North Rawhide-Caballo surface coal
mines,Carter Mining Company Project,Wyoming;
hydraulic analyses for relocation requirements at
the multi-purpose Kootenai Dam,Montana.
Civil-Planning Hydrotechnical Design Institute,
Bucharest,Rumania.
Design Engineer promoted to Head of Water Resources
Systems Design Department in 1967.Directed a team
of 40 engineers,designers and draftsmen.
Assignments included evaluation of regional water
resources and needs,determinations of reservoir
characteristics and performance,analyses of river
basins for multi-stage development,cost evaluation
of waterworks,economic studies and design of multi-
purpose water resources systems.Important assignments
were as:Project Manager for determining the optimum
staged development of the Mures River Basin,under
the United Nations Development Program;Project
Manager for hydrological-hydraulic studies of the
Danube River between Orsova and Tulcea for the
Hydro-Power Plant,"Iron Gates."
Research Hydrotechnical Institute,Bucharest,Rumania.
Research Engineer.Duties included making hydrologic
ALEXIS C.VIRCOL
Power Planning Engineer
-3-
May 1959
to September 1963:
(Continued)
September 1958
to May 1959:
Technical Papers
and Articles:
April 1979
analyses of flood and drought frequencies,stochastic
hydrology,reservoir sedimentation,spillway design
floods and open-channel and reservoir flood-routing.
Most important achievements were:a complete hydrologic
survey of the Mures River Basin and a generalized
study of flood peaks in Rumania,utilizing morphological
data.
Hydro-Industrial Enterprise Co.,Bucharest,Rumania.
Junior Hydro-Civil Engineer.Duties included follow-
up assignments during construction,erection-phase
and final start-up of civil works such as earth-
filled dams,hydro-power plants,channels,spillways
and related items.
''Hydrological Studies on the Mures River Basin,"
I.S.C.H.Publications,Hydrological Series,Bucharest,
Rumania,1963.
"Analysis of Flood Marks for Estimating the Flood
Peaks,"LS.C.H.Publications,Hydrological Series,
Bucharest,Rumania,1962.
'~pplication of the Risk-Uncertainty Theory in the
Design of the Flood-Control System in the Crisul-Alb
River Basin,"Rev.Hidrologia,Meteorologia and
Gospodarirea Apelor,1969 (no.2,),Bucharest,
Rumania.
"Use of Linear and Dynamic Programmation in Determining
the Optimal Staged Development of Water Supply Works
for Urban and Industrial Area of Brasov City,"Rev.
Hidrologia,Meteorologia &Gospodarirea Apelor,1970
(no.4),Bucharest Rumania.
"General Equations for Drought-Curves of the Mures
River at Arad Station and a Method of Estimating the
Ground-Water Reservr,"Rev.Ridrologia,Meteorlogia
and Gospodarirea Apelor,1965 (No.1),Bucharest,
Rumania.
''Hydro technical Structures"(Handbook for technical
high schools),coauthor,Ed.Didactica &Pedagogica,
1965,Bucharest,Rumania.
ENGINEERING COMPANY
GEORGE V.VOLLAND
Department Head,Power Resources Division
Professional Engineer -III i no is...
Degrees:
Languages:
Bachelor of Mechanical Engineering
Union College,1965
Bachelor of Arts in Economics
Union College,1965
English and Spanish
-
-
Professional Societies:
Illinois Society of Professional Engineers
National Society of Professional Engineers
Harza Engineering Company since 1967.
Power Resources Division.Department Head,1977 to date;Planning Engineer,1967-77.
Experience Highlights:
Project Manager for Brazil pumped-storage projects through prefeasibJiity study.Technical and cost studies were
made of the following two projects:(1)the CIPO ProJect,which would develop a total head of about 550 meters
and have an installed capacity of up to 6,000 MW in multiple stages,and (2)the Primavera Project,which would
develop 1,000 MW utilizing a head of about 100 meters.
Project Manager for the Kootenai River Hydroelectric Project through license application to the Federal Energy
Regulatory Commission (FERC).ResponSible for preparation of FERC license application for the proJect,which
would develop a capacity of 144 MW utilizing a head of about 28 meters.
PrOject Manager for the Tavera-Lopez Project,Dominican Republk,through feasibility report.Responsible for
technical,economic,and financial studies leading to financing of the prOject which consists of the expansion of
an 80·MW hydroelectric generating station and a 50·meter high reregulating dam and powerstatlon having an
Installed capacity of about 20 MW.
Project Manager for the Chlmbo ProJect,Ecuador,through prefeasibility study.Responsible for coordination
of studies leading to the identification,selection and technical and economic justlficat"lon of a scheme for the
development of the hydroelectric resources of the Chimbo River Basin,consisting of a 460-MW development in
three powerstations including a 40-MW pumped-storage project.
Project Manager for the Betania Multipurpose Project In Colombia,through feasibility report.Responsible for
preparation of alternative fill and concrete dam layouts and cost estimates,power operation STudies,and economic
eval uati ons.
Project Manager for the Santa Cruz System Expansion Project,Bolivia,through feasibility report leading to the
technical and economic justification of the expansion of the system.The project consists of a 16-MW gas
turbine generating plant and a 25-km,69·kV transmission line and SUbstations.
GEORGE V.VOLLAND
Assistant Project Manager for the 80-meter high rockfill dam and 270-MW Cerron Grande PrOJect,EI Salvador,
through feasibility study;and for the expansion of the CEl system,EI Salvador,responsible for power market
analysis,evaluation of existing system,and economic analysis of future expansion programs.
Responsible for economic studies of water resource developments in the Gauley and Kanawha Basins in West
Virginia.
Prepared power,energy,and cost analyses of the Corpus Project.Studies included analyses of reservoir elevations
and sites for a proposed 2,OOO-MW to 9,OOO-MW hydroelectric development on the Parana River between Argentina
and Paraguay.
Prepared economic evaluations of a 3-pro;ect,1,200-MW development for the Uribante and Caparo Basins in Venezuela.
Prepared economic and finanCial analyses of 4,050-MW Yacyreta Project on the Parana River between Argentina
and Paraguay.
Prepared a 30-year financial forecast for the Blue Mounta'ln Water Supply PrOjPct,Jamaica,as a part of the
feasibility study to support loan application to international lending agencies.
Responsible for the economic Justification and layout and cost estimates for the rehabilitation and expanSion
of the distribution system for the City of Medan,North Sumatra,Indonesia,through the feasibility study.
Participated in system load flow studies and design for the West Pakistan P()wrr Consulting Services;power market
survey for Sou thern Bol ivia,a 10-year financial forecast for the Empr8sa NaCional de Electricidad,Bol ivia;evaluation
of thermal electric plants for the POtOSi Electric Power Supply Project,Bolivia,and the financial analysis,layout
and cost estimates of earthfill dams for 250·MW lake Havasu Pumped-Storage ProJect,Arizona.
1965 to 1967:
U.S.Peace Corps,Ecuador.
Resident Engineer for the Ecuadorian Institute of Elect(lfication.Responsible for distribution system construction
and maintenance,and for construction of small dI8SP!,1f'nerating plant.
Technical Papers and Articles:
"An Introduction to Physical Analogues in Economics,"unpublished thesis.
2/79
I""'"
ENGINEERING COMPANY
BI·HUEI WANG
Associate and Assistant Chief Hydrologist
Degrees:
Languages:
Doctor of Philosophy In Hydrology
Utah State University,1970
Master of Engineering in Hydraulics
Asian Institute of Technology
Bangkok,Thailand,1967
Bachelor of Science in Agricultural Engineering
Taiwan UniverSity,Taipei,Taiwan,1955
English,Chinese,and Japanese
-
Professional Engineer -Taiwan
Professional Societies:
American Geophysical Union
American Society of Civil Engineers
(Committee Chairman,Surface Water Hydrology)
American Society of Mining Engineers
Harza Engineering Company since 1972.
Associate and Assistant Chief Hydrologist,1979.
Hydrology Division:Assistant Head,1978 to date,Head,Hydrology Department,1973-78;Senior Hydrologist,
1972-73.
Experience Highlights:
As Assistant Chief Hydrologist,reviews hydrologic analyses of all types for quality of analyses and results.
As Assistant Head of the Hydrology DiviSion,directs,supervises,and performs hydrologic analyses of all types,such
as determination of spillway design floods,flood frequency analyses,determination of dependable water yield,
stochastic hydrology,sediment analyses,and mathematical simulation of water resources systems.
Directed comprehensive hydrologic analyses for the San Lorenzo hydroelectric project In EI Salvador,the Jordan
Valley irrigation and hydropower project in Jordan,the Black River Upper Morass irrigation and drainage project
in Jamaica,and the Northeastern Honduras hydroelectric site survey In Honduras.
Directed probable maximum flood analyses and reservoir operation studies for the Kajakai irrigation,hydroelectric,
and flood control project in Afghanistan.
Participated at review level capaci ty in the comprehensive hydrologic studies for the Bewnia and Sogamoso hydroelectric
projects in Colombia,Guri and Uribante·Caparo hydroelectric projects in Venezuela,Chimbo hydroelectric project
In Ecuador,and Puyango-Tumbes irrigation and hydroelectriC project in Peru and Ecuador.
Project Manager for review of flood analyses for the Aliens Creek nuclear power project,Texas,and the Quanicassee
nuclear power proJect,Michigan,for the U.S.Atomic Energy Commission.
BI·HUEI WANG
Project Manager lor a study of water supply Clnd demand relationship for a proposed lignite fuel power prOjl,ci,
North Dakolc1.
Project Manager for development of the Caronl River streamflow forecasting system in Venezuela.
Directed tl,errnal discharge and supplementary cooling studies for Dean H,Mitchell Station in Indiana for the Northern
Indiana Public Service Company and hydrothermal rnodellllg for Black Dog Slatlon in MlIlnesota for Northern St,lles
Power Company,
Directed flood and low flow analyses for the 1710-MW Stony Creek pumped-storage project,Pennsylvania,in
connection with FPC license appl ication.
Esflmated the reservoir sediment deposition and downstream degradation for the Foothills Water Supply Project,
Colorado,and the Powder River Water Supply Project,Wyoming.
Directed flood operation study for Bath County Pumped-Storage Project in Virginia and dam failure analyses for
Piney Project in Pennsylvania.
1967 to 1972:
Utah Slate University,Logan,Utah.
Teaching Assistant,Research Assistant,and Research Engineer.Assignments included the following:instructing
hydraul ic experiments;directi ng graduate students'research programs toward M.S.and Ph.D.degrees,and developmen t
of mathematical models and computer programs for simulating hydrologic and water resources systems.
1967:
U.S.Bureau of Reclamation,Bangkok,Thailand.
Civil Engineer.Pamong ProJect.Assignments included determination of irrigation requirements,computer
programming,and comprehenSive water resources development planning.
1966 to 1967:
SEATO Graduate School of Engineering (presently Asian Institute of Technology),Bangkok,Thailand.
Graduate Assistant and Research Associate.Duties included research in hydrology and instruction of graduate
hydraulic experiments.
1956 to 1965:
Taiwan Water Conservancy Bureau,Taipei,Taiwan.
Junior Engineer,Associate Engineer:Chief,Survey and Design Team, Shih-men.Rotation Irrigation Project.
Assignments included the [ollowing:hydraulic and structural design of irrigation and drainage structures,hydrologic
and economic analyses of drainage and tide prevention projects;and supervision and review of water resources
development projects of all type.Was honored by the Governor of Taiwan in 1959 and was awarded the Outstanding
Engineer AWClrd by Taiwan Water Conservancy Bureau in 1963.
Technical Paper and Articles:
"Insolation on Natural Watershed,"M,Engineering TheSIS,SEATO Graduate School of Engineering,Bangkok,
Thililand,1967.
"Influence of Mountain Groundwater on Streamflow:'with Roland W.Jeppson,Utah Water Research Laboratory,
Utah State University,Logan,Utah,1970.
"Combined SurfClce Water -Groundwater Analysis of Hydrological System with the Aid of the Hybrid Computer,"
with W.J.Morris,N.W.Morgan,and J.P,Riley,American Water Resources Association Conference,Las Vegas,
Nevada,November 1970.
"Evaporation from Shallow Lake,"with J.P.Riley,American Water Resources Association Conference,Washington,
D.C ..October 1971.
"Hybrrd Computer Simulation of Groundwater Regimes,"Fall Annual Meeting of the American Geophysical
Union,San Francisco,December 1971.
"Water Resources Management Model,Upper Jordan River Drainage,Utah,"with Felix,Gold,Jones,and Riley,
Utah Water Research Laboratory,Utilh State Un iversity,Logan,Utah,March 1973.
5/79
ENGINEERING COMPANY
LEEI·LUOH WANG
Power Planning Engineer,
Power Resources Division,
Resources Development Branch
Degrees:
Languages:
Master of Science in Civil Engineering
Utah State University,1966
Bachelor of Science in Agricul tural
Engineering,Hydraulic Section
National Taiwan University,China,1958
English and Chinese
Professional Engineer -Illinois
Harza Engineering Company since 1966.
Power Planning Engineer,Power Resources Division,1971 to date,Planning Engineer,Water Resources Division,1966-71.
Experi ence High lights:
Supervise the planning studies of assigned hydroelectric and other projects.Also act as Project Manager for some of
these projects.In this capacity,prepare budget,work schedules and reports;coordinate work assignments;monitor
cost and progress;and maintain liaison with client.
Project Manager for prefeasibility study of the 800-MW Cuffs Run Pumped-Storage Project,Pennsylvania;augmentation
reservoir siting study,Pennsylvania and Maryland;feasibility studies of expansion of Lower Susquehanna powerplant,
Pennsylvania,including the 230-MW Safe Harbor ProJect and the 108-MW Holtwood Project;load dispatch study of
the Virginia Electric and Power Company's System,Virginia;and the technical feasibility study of the 1,800-MW
Sogamoso Project,Colombia.
Project Manager for storm drainage studies,Village of Kenilworth,Illinois;probable maximum flood studies at
Monticello Nuclear Power Station,Minnesota;radioactive pollutant dispersion study for Zimmer Station,Ohio;and
the Columbus Flood Plan Study,Indiana.
Power System Special ist to National Power Company,Iceland.Supervised power system study for the Thjorsa Basin
that included two existing powerplants,five potential reservoirs,ten proposed hydroelectric plants,a pumping station,
and various diversion schemes.
Participated in studies of the Puyango·Tumbes Basin Development,Ecuador-Peru;the Parana River development,
Corpus Project,Argentina;the 10,OOO·MW Guri Hydroelectric Project,Venezuela;and the 1,500-MW Patia
Hydroelectric Project,Colombia.
1966:
Utah Water Research Laboratory,Utah State University,Logan,Utah.
Graduate Research Assistant on a project to develop a plan for the water needs of the State of Utah.
LEEI-LUOH WANG
1964 to 1965:
International Engineering Company,San Francisco,California.
Assistant Engineer.
Worked on a series of feasibili ty studies for hydroelectric and irrigation projects in Tunisia and Turkey.
1962 to 1964:
Utah State University,Logan,Utah.
Graduate Student.Worked for Utah State Department of Highways as Soils Engineer during the summer,conducting
soil analyses and site investigations for interstate highway projects.
1959 to 1962:
Taiwan Provincial Water Conservancy Bureau,Taipei,Taiwan.
Junior Irrigation Engineer,Planning Division.
1958 to 1959:
Chinese Air Force.
Engineer Officer.
Technical Papers and Articles:
"Application of Multivariate Analysis in Predicting the Water Yields in Utah,"unpublished thesis.
"Estimating Water Yields in Utah by Principal Component Analysis,"with A.L.Huber,Utah Water Research
Laboratory Report PRWG 35 a-1 ,June 1967,
B/7B
-
-
-
Date of Birth:
Citizenship:
Degree:
Language:
Professional
Registration:
Professional
Societies:
Certification:
January 1977
to Date:
June 1975
to August 1975:
March 1979
HARZA ENGINEERING COMPANY
RALPH L.WATT,JR.
Civil Engineer
August 1,1953
U.S.A.
Bachelor of Science in Civil Engineering
1977,University of Illinois
English
Engineer-in-Training -Illinois
American Society of Civil Engineers
Illinois Society of Professional Engineers
Western Society of Engineers
a.S.H.A.Construction Supervisor
Harza Engineering Company,Chicago,Illinois.
Engineer.Scheduling Department,Construction
Division.Responsible for studies of construction
methods,construction scheduling,manpower analysis,
equipment selection,network design,CPM data processing
and updating on the following projects:
Lyallpur-Multan-Guddu 500-kV Transmission Line and
Substation,Pakistan;Wastewater Treatment Facilities
at the Will County,Kincaid,Ridgeland,Quad Cities,
Dresden,and Zion Power Stations,all in Illinois;
Quad Cities Power Station Intake Structures,Illinois;
renovation of Lock and Darn No.1,Minnesota;San
Lorenzo Hydroelectric Project,El Salvador;Itapueara
Hydroelectric Project,Brazil;Burlington Flood
Control Project,North Dakota;Maqarin Diversion
Project,Jordan;and Yacyreta Hydroelectric Project,
Argentina and Paraguay.
City of Naperville,Naperville,Illinois.
Inspector.Public Works,Engineering Department.
Responsibilities included inspection and functioning
as owner's representative on various construction
projects.
ENGINEERING COMPANY
Professional Engineer ~Alaska,California,Colorado,Florida
and Illinois
R.P.WENGLER
Vice President a d Head,
Advanced Structural &
Hydraulic Branch
,..
Degrees:
Languages:
Master of Science in Civil Engineering
University of Minnesota,1954
Bachelor of Science in Civil Engineering
University of Minnesota,1952
Bachelor of Business Administration
University of Minnesota,1952
English,German and working knowledge of French
,..
,..
Structural Engineer -Illinois
Professional Societies:
American Concrete Institute
American Nuclear Society
American Society of Civil Engineers
Earthquake Engineering Research Institute
United States Commission on Large Dams
Harza Engineering Company since 1954.
Vice President,1978.
Senior Associate,1976,
Associate,1967,
Head,Advanced Hydraulic and Structural Branch,1976 to date;Head,Applied Engineering and Mechanics
Division,1969-76;Civil Design Branch:Head,Structural Design Department,1967-69;Head,Civil Department,
1964-67;Assistant Section Head and Section Head,1960-64;Group Leader,1957-59;Senior Engineer and
Assistant Group Leader,1956;Junior Engineer,1954-55.
Experience Highlights:
Responsible for supervision of the divisions assigned to the Advanced Structural and Hydraulic Branch.
These divisions design and prepare drawings for a wide variety of structures including arch dams,spillways,
transmission towers,substations,bridges,post-tensioned gate anchor systems,penstocks and nuclear plants.To
support these designs,continuing effort is made to improve computer programs for analysis of structural and
hydraulic problems with "Slate of the Art"techniques.
Project assignments have progressed from trial load analysis of the 250-ft.Mayfield arch dam in Wash i ngton
through analysis and design of the 178-meler Karadj arch dam,I ran;606-ft.Mossyrock arch dam,Washington;
and supervision of the design of the 200-meter Reza Shah Kabir arch dam,I ran.
R.P.WENGLER
Member of Consul ling Board of Farraday Dam,Oregon.
Technical Papers and Articles:
"Analysis of Arch Dams on G-15 Computer,"by Wengler and Vel trop,Fourth Annual G-15 Users
Exchange Conference.
"Buttress Dam Design by Electronic Computer,"by Wengler and Veltrop,Symposium on Analysis
and Design of Hydraulic Structures,1ndiana I nstitu te of Science,1962.
"Crown Cantilever Analysis of Arch Darns,"by Wengler and Shieh,Eighteenth Conference Bendix
Users Exchange Organization.
"Desiqn of Karadj Arch Dam,"by Wengler and Veltrop,Journal of Power Division,ASCE,March
1964.
"Structural Behavior of KaradJ Arch Dam,"by Veltrop,Wengler and Azri.Eighth International
Congress on Large Dams,Edinburgh,May,1964.
"Computers as a Tool in Planning Hydraulic Structures,"by R.P,Wengler,ASCE Annual Meeting
and Environmental Engineering Conference,Kansas City,October,1960.
"Section 14 -Arch Darns,"by Houk and Wengler,HANDBOOK OF APPLIED HYDRAULICS,
Third Edition.
"Design of Mossyrock Arch Dam,"by R.P.Wengler and W.Y.Shieh,ASCE National Structural
Meeting,Portland,Oregon,April 1970.
"Effect of Safety Factor and Concrete STrength on Cost of Arch Dams,"by R.P.Wengler,
Proceedings of the Engineer Foundation Research Conference -RaiJid Construction of Concrete
Darns,Asilomar,California,March 1970.
"Safety of Darns -Design Considerations,"by R.P.Wengler,Hydraulic Power Commi ttee
Meeting,Edison Electric Institute,Lake of the Ozarks,Missouri,May 1977.
8178
JACK WEST
•Numerous engineering studies,analyses,purchase
specifications,and negotiations for various Alaskan
utilities.
•Multiple small hydroelectric (10-30 MW)feasibility
studies and investigative field work (site inspections
economic analysis,hydrology,load projections,etc.)
for Alaskan municipa I and REA electric uti I ities.
-•Extensive remote areas engineering for RCA Alaska
Communications and the nationa I defense (Whi te
AI ice)systems.
-
-
-
Prior to joining CH1M HIll.Mr.West was prin.c.ipal of
Jack West Associates,a private consulting firm.In earlier
Alaska years he was a staff engineer with RCA Service Company,
RCA Alaska Communications J and an Associate Engineer with
Robert W.Retherford Associates Consulting Engineers.In
Missouri and Kansas /Mr.West was an engineer for B lack and
Veatch /Bu rns McDonne II,and J.F.Pritchard Construction
Engineers.
Mr.West has supplemented his professional background with
extensive world travel often professionally related.An
example was 1974 travel to Israel for familiarization and
training on exotic vapor turbines playing a critical role in
the ope rati on of the Trans-Alaska pi pe line.Other trave I
has included all p rovi nces and terri tor;es of Canada,
Denma rk,Norway,Swi tzer land,Kenya and Tanzani a (East
Africa),France,Jamaica,Belize (Central America),and
Mexico.
Professional Registration
Alaska
•JACK WEST
Sen ior Consul tant
Education
8.S.,Electrical Engineering,University of Kansas,1961
Post graduate course work,University of Alaska and Universi ty
of Oregon extensions
Experience
Practicing in Alaska for 16 yea rs,Mr.West has designed and
construction-managed electric power and control projects of
a wide variety.Included in these projects are diesel and
gas turbine generation,transmission and distribution lines,
substa tions,remote commun i cations systems,and comp lex
industrial control and instrumentation systems.Prior to
Alaska Mr.West participated in electrical and fluid mechanics
desi gn of hyd rocarbon refineries and gas liquefaction
plants for a construction engineering fi rm.Alaska experience
includes the following:
•Special consultant to Alyeska Pipeline Service
Company for startup and first year of pipeline
operation.Responsi ble for startup of all 62
remote mainline gate valves full length of pipeline.
Extensive control,control power,and instrumentation
work at all pump stations and Valdez remote control
center.
•Special consultant to RCA Alaska Communications
designing prototype remote unattended power systems
for 27 microwave sites controlling the Alaska
Pipel ine from the Va Idez control center.
•Design,construction management,and startup of
diesel/gas turbine generating units throughout
Alaska.
•Consulting on generation control (voltage regulation,
speed governing,etc.)throughout Alaska.
•Design and resident engineering on substations,
distribution lines and equipment,and transmission
lines to 138 kV.
K
1
7
9
•
•
Desi gn and i mplacement of a 4-mi Ie-long,lOa-ton,
25-kV submarine cable.
Supervision of retrieval,repai r,and replacement
of damaged 1.5-mi Ie,15-kV subma rine cables.
ENGINEERING COMPANY
Professional Engineer -Illinois
Professional Society:
American Society of Civil Engineers
RICHARD A.WESTMORE
Water Resources Planning Engineer
Master of Science in Water Resources Management
University of Wisconsin,1971
Bachelor of Science in Civil Engineering
University of WiSCOnSin,1970
Degrees;
-
Harza Engi neering Company since 1971.
Water Resources Division'Water Resources Planning Engineer,1973 to date.Flood Control Engineer,Pakistan,
1975.Sanitary Engineering Division:Civil Engineer,1971-73.
Experience Highlights:
Planning Engineer for feaSibility study of upgrading five existing low·head hydroelectric projects on the S1.Joseph
River in Indiana and Michigan,and for review of operating procedures for a small hydro project in Upper Michigan.
Work included capacity and energy studies,evaluation of alternatives for upgrading the plants,and preparation of
planni ng reports.
Planning Engineer for hydraulic study of a proposed floodway for the Sula Valley Flood Control Project,Honduras.
Project Manager for the City of Williston,North Dakota,Water Supply Study.Work involved evaluation of
alternative measures to improve the city's raw-water supply system.
ProJect Manager for the City of Sioux Falls,South Dakota,Water Supply AI terna tives Study,involving evaluation
of ground-water supply al ternatives,updating of cost estimates for su rface-water supply alternatives,and appraisal
of treatment plant requirements.
Planning Engineer on resident assignment in the Norte Grande Region,Chile.Prepared water-demand forecasts,
formulated and casted alternative water supply plans,and prepared sections of the planning report.
Project Manager for flood insurance studies for seven communities and unincorporated areas in two counties in
Illinois,for the Department of Housing and Urban Development,Federal Insurance Administration.Planned,
conducted,and supervised hydrologic and hydraulic analyses to develop water surface profiles for floods of various
frequencies using computer simulation methods.Participated in public meetings,floodway negotiations,and
project coordination and management activities.
Flood Control Engineer on resident overseas staff for flood control engineering services to the Government of
Pakistan.The proiect involved appraisal of the existing flood forecasting and flood warning systems and the current
flood control facilities throughout the country,and development of a comprehensive program for improvements.
RICHARD A.WESTMORE
Project Manager for I nventory of Urban Water Damages in the Chicago Metropol itan Area,a study of the causes
and magnitude of overbank flood and storm water drainage damages in 60 communities located along 20 watercourses
in Cook and DuPage Counties,IllinoIs.
Assistant Project Manager for the Greater Egypt Regional Water Systems Study.The project involved preparation
of a master plan for phased expansion of four regional water systems and recommendation of pol icy-level
guidelines for system management.
Performed bench-scale treatability studies and laboratory tests,over a four-month period,for a joint municipal-
industrial wastewater treatment project for the City of Oconto Falls,Wisconsin,and the Scott Paper Company.
Other assignments have included preparation of design criteria,conceptual designs and layouts,quantity and cost
estimates,econom ic analyses,and report drafts and memoranda for regional planning proiects.Projects in th is field
included the Regional Sanitary Sewerage Plan for the seven-county Southeastern Wisconsin Region,the Pike River
Watershed Sewerage Plan for a 50-square mile area in Wisconsin,and an interim Water Quality Management Plan
for a three-county area in Illinois.
1970 to 1971:
University of Wisconsin.
Teaching Assistant in Water Resources Engineering and in Fluid Mechanics.Assigned as a Research Assistant to
undertake surveying and stream-gaging for a research project in the study of thermal and treated sewage effluent
mixing lones.
Technical Papers and Articles:
"An Analysis of the Enforcement Conference Procedure in Achieving Water Pollution Abatement in Lakes
Michigan and Superior,"unpublished,1911.
"An Up-dated Look at the TVA as an Institution:Its Pol icies and Programs,"unpubl ished,1911.
"Water Resources Education Requirements of an Engineering Firm,"with Alan H.Schultz,presented at the ASCE
National Convention,Chicago,Illinois,October 1918,and accepted for publication in the Journal of the Water
Resources Planning an~Management Division (ASCE},September 1919.
7/79
ENGINEERING COMPANY
Honorary Societies:
Tau Beta Pi,Sigma Tau,and Sigma Xi
CLI FFORD L.WI LLiS
Vice-President and
Chief Geologist
Doctor of Philosophy (Geology)
University of Washington,1950
Bachelor of Science Mining (Geology)
Engineering
Universi ty of Kansas,1939
Degrees:
-
Honors:
Haworth Distinguished Alumnus Award ior the University of Kansas
Listed:
American Men of Science
Dictionary of I nternational Biography
Who's Who in Engineering
Professional Societies:
-
-
American Insti !ute of MI ning,Metallurgical and Petroleum Engineers
American Association of Petroleum Geologists
Association of Engineering C;eologists
International Society of Rock Mechanics
Geological Society of America (Fellow)
Geological Society 01 London (Fellow)
-
Harza Engineering Company since 1952.
Vice·President,1967;Associate.1957.
Chief Geologist,1954;Consulting Geologist,1952.
Experience Highlights:
-
Responsible for geological Irwestlgations and Interpretations on company assignments.Provides advisory services
and special consultation to clients.Major projects have included,among others,the Mangl8 and Tarbela Projects
on the Indus BaSin development,West Pakistan,totalling more than 250 million cubic yards in the volumes of
the two dams and more than $1 billion in construction cost;Reza Shah Kabir (200-mJ and Karadi (178-m)arch
dams,Iran;Mossyrock {606-ft.}arch dam,Washington;and the Wanapum and Priest Rapids hydroelectric
projects on the Columbia River,Washington;and the 10,087 MW Guri prOject on the Caroni River,Venezuela.
1946 to 1954:
University of Washington,Dep8rtrnent of Geology;Seattle,Washington.
Assisiant Professor.
eLi FFORD L.WI LLiS
1939 to 1946:
The Carter Oil Company;Tulsa,Oklahoma.
Geologist,Exploration Geophysicist,and Research Geochemist.
3/78
ENGINEERING COMPANY
-FRANK DER-L1ANG YOUNG
Hydrologic Engineer
,...
Degrees:
Languages:
Doctor of Philosophy in Civil and Environmental
Engineering -Hydraulics
Cornell University,1976
Master of Science in Civil Engineering
California Institute of Technology,1972
National Taiwan University,1971
Bachelor of Science in Civil Engineer
National Taiwan University,1968
English anel Chinese
-
Professional Engineer --Engineer·in-Training -Illinois
Professional Societies:
American Society of Civil Engineers
International Association for Great Lakes Research
Harza Engineering Company since 1976.
Hydrology Division:Hydrologic Engineer,1976 to date.
Experience Highlights:
Served as Project Manager and developed analytical model to simulate performance of existing cooling ponds at
Black Dog powerplant,Minnesota.The model was used to develop operating rules to optimize energy generation
within constraints of eXisting permit terms.
Developed or applied mathematical models for streamflow forecasting,dam-seepage analysis and dam-burst
floodwave prediction.
Mathematically modeled thermal plume behavior of heated plant water discharged to Lake Michigan from the
D.H.Mitchell Power Station in Indiana.The two-dimensional model was calibrated to measure data for three
seasons,and the potential changes due to alternative heat dissipating facilities were modelled.
Hydraulic computations for potential interconnection of the north and south arms of the Great Salt Lake,Utah
were made.
Available water supply was estimated and storm and flood characteristics were analyzed for the Black Bush
Block III Frontlands study in Guyana S.A
1972 to 1975:
Cornell University,Ithaca,New York.
Teaching Assistant,Research Assistant and Research Associate at the School of Civil and Environmental Engineering.
Responsible tor teaching and research in fluid mechanics,hydraulics and hydrology.Major research projects related
to investigation of stratified lake circulation and finite element analyses of thermal pollution for large bodies of water.
FRANK DER-lIANG YOUNG
1971 to 1972:
California Institute of Technology,Pasadena,California.
Graduate Teaching Assistant in the Keck Laboratory of Water Resources and Hydrodynamics.Gave
instruction in the laboratory (eldtlng to hydraulic experiments.
1969 to 1971:
National Taiwan UniverSity,Taipei,Taiwan.
Graduate student in the Department of CiVil Engineering.
1968 to 1969:
Army Corps of Engineers of RepubliC of China.
Assistant Engineer on Ma-Tzu Is!e.Participated In the design of small darns,tunnels,water resources
developments,rural highway systems,and housing construction.
Technical Papers and Articles:
"Nonlinear Rarified Couette Flow of Binary Gas Mixtures,"proceedings of the Chinese Society of Mechanical
Engineers,No.49,pp.1-12.,March 1972.
"Env'lronmental Problems AssociClted with Fluid Flow,"(With R.H.Gallagher)in Advanced Topics 'In the Finite
Element Analysis,Newport,Rhode Island,pp.17.524-548,August 1975.
"Finite Element Analysis of Stably-Stratified Wind-Driven Circulations,"(with J.A.Liggett and R.H.Gallagher).
Paper presented at Symposium on Modeling of Transport Mechanisms In Oceans ilnd Lakes,CCIW,Burlington,
Ontario,October 1975.
"Dynamics of Transient Wind-Driven Circulation in a Stably Stratified Basin by the Finite Element Analysis,"
Ph.D.Thesis,Cornell University.Ithaca.New York,283 p.,January 1976.
"Steady Stratified CirculatIOn In a CdVlty,"(with J.A.Liggett and R.H.Gallagherl,Journal of Engineering
Mechanics Division,ASCE Vol.102,No.EM1,pp.1-17,February 1976.
"Unsteady Stratified Circulation In a Cavity,"(with J.A.Liggett and R.H.Gallagher),accepted for publication
in the Journal of Engineering Mechanics DiviSion,ASCE,In press.ASCE Vol.102 No.EM6,pp.1009-1023,
December 1976.
"Transient Finite Element Shallow Lake Circulation,"(with J.A.Llggettl.accepted for publication in the
Journal of Hydraulics Div'lsion,ASCE,In press.ASCE Vol.103,No.HY2,pp.109-121,February 1977.
1178
ENGINEERING COMPANY
Professional Societies:
Professional Engineer -Illinois
ROBERT A.ZYLMAN
Planning Engineer
Bachelor of Science in Civil Engineering {Honors}
Mich igan State University,1972
Degree:
Amencan Society of Civil Engineers,Associate Member
Water Pollution Control Federation
Harza Engineering Company since 1974.
Power Resources Division Planning Engineer,1974-75 and 1976 to date.Con::.truction DivIsion'Resident
Engineer,1975-76.
Experience Highlights:
Assistant Project Manager for feasibility study and FERC license permit application of the 3,OOO-MW Brumley Gap
Pumped-Storage Project in Virginia.
Acting Project Manager of a feasibility study for electric power system expansion,Honduras,including the 22.5-MW
EI N ispero Hydroelectric Project and the 30-MW Puerto Cortes Diesel Project.
Planning and layout engineer for various feasibility level studies on hydroelectric power proJects.
Performed inspection,documentation,and field engineering on dam restoration proJec t,Upper and Lower Darns,
Occoquan,Virginia.
-
Participated In the prefeasibility study of the CE L System Expansion,EI Salvador,including repon writing,
economic evaluation,and project layout of alternative 5 de Noviembre second power plant schemes.
Performed flood routing studies for Guri Stage III Development,Venezuela,and tunnel diversion studies for the
Reza Shah Kabir Dam,Iran.
1972 to 1974:
City of Portage, Portage,Michigan.
Civil Engineer,Department of Public Works.Duties included all phases of municipal engineering design and
construction,publiC business,and professional contacts.
1972:
Post-graduate studies,for three months,in water resources engineering under E.P.A.Fellowship.
ROBERT A.ZYLMAN
1972:
Eastern Mapping Cornpany,Pittsburgh,Pennsylvania.
Survey crew chief and field represent<Hlve.Duties included surveying and field control of sewage mapPiIlg
project.
1971 to 1972:
Michigan State University,East Lansing,Michigan.
Part-time Engineering Assistant In the DIVISion of Engineering Research.
6/79
Woodward-Clyde Consultants
.PROJECT ORGANIZATION AND PERSONNEL
ORGANIZATION CHART AND RESUMES
-
Woodward-Clyde Consultants
PROJECT ORGANIZATION AND PERSONNEL
Woodward-Clyde Consultants proposes an organization for the
Susi tna proj ect as shown on the figure on the next page.
The resumes of all identified personnel are attached.
All project personnel are well qualified for their project
functions.The Project Manager,Mr.George Brogan,has
conducted several Alaska studies,including the extensive
fault studies for the Alyeska oil pipeline.Over the last
12 years he has conducted and managed many projects in his
specialty of seismic geology.
The subtask leaders,Ms.Norma Biggar,Dr.William Savage,
and Mr.Maurice Power,are all highly qualified and they
have had experience on s imiar proj ect work.They will be
supported by WCC professional and sub-professional staff as
needed.
Dr.Ulrich Luscher,the proposed Principal-in-Charge,has
conduc ted many mul ti-d isc ipl ined proj ects.Among many
Alaska projects on which he has worked during the last 10
years,he has headed WCC's extensive involvement in the
design and construction of the Alyeska oil pipeline and is
presently heading the firm's work for the Northwest Alaska
gas pipeline.
Dr.L.S.Cluff is WCC's Principal-in-Charge of Geology,
Seis~nology and Geophysics,and Dr.I.M.Idriss is the
Principal-in-Charge of Earthquake Engineering.Both are
internationally renowned experts in these specialties.Dr.
R.Forbes has had long association with the Geophysical
Institute of the University of Alaska,and is a recognized
expert in Alaska geology and seismology.As Senior Advisors
to the project,these individuals would provide the nec-
essary technical direction and peer review.
Woodward-Clyde Consultants
I-~LAS~-;ow~--l
I AUTHORITY I
I I
:Project Sponsor :I-----I----J
r-----------,
:HARZA ENGINEERING I
I COMPANY :
,-------.I
I I Prime Contractors I
WCC PRINCIPAL IN CHARGE I IL_____:-_____1
U.Luscher
WCC PROJECT MANAGER SENIOR ADVISORS
L.S.Cluff
G.E.Brogan I.M.Idriss
R.B.Forbes
PROJECT GEOLOGIST PROJECT SEISMOLOGIST PROJECT ENGINEER
N.Biggar W.U.Savage M.Power
PROJECT STAFF AS REQUIRED
ORGANIZATION CHART FOR
SEISMIC GEOLOGY,SEISMOLOGY &EARTHQUAKE ENGINEERING
George E.Brogan
EDUCATION
San Diego State College:
San Diego State College:
REGISTRATION
M.S.,Geology,1969
B.A.,Geology,1966
Woodward·Clyde Consultants
engineering geology
seismic geology
structural geology
geomorphology
Registered Geologist:California
Certified Engineering Geologist:California
PROFESSIONAL HISTORY
Woodward-Clyde Consultants,Los Angeles/Orange,California,Associate,
1978-date;Deputy Director of Geology,1976-date;Oakland,
California,Staff Geologist to Senior Project Engineering
Geologist,1971-1975
Woodward-Lundgren and Associates,Oakland,California,Consultant
in Geology,1969-1971
University of Nevada,Reno,Department of Geology-Geography,Teaching
Fellow,1968-1971
Humble oil and Refining Co.,Kingsville,Texas,Production
Geologist,1967
San Diego State College,Department of Geology,Teaching Assistant,
1966-1968
U.S.Navy Electronics Laboratory,San Diego,California,Data Analyst
with San Deigo State College Foundation,1964-1968
REPRESEtJTATIVE EXPERIENCE
Mr.Brogan has practiced engineering geology since 1966,and has world-
wide experience in engineering geology and seismic geology on projects
including nuclear and conventional power plants,dams,tunnels,pipelines,
airports,high-rise buildings,offshore drilling platforms,and liquefied
natural gas terminals.In connection with these numerous investigations,
he has completed complex projects in diverse geographic and climatic
environments.He was in charge of the evaluation of active faults
for the Trans-Alaska Pipeline System,the evaluation of the Bocono
fault in Venezuela for the Yacumbu tunnel,the mapping and evaluation
of the Wasatch fault in Utah,the evaluation of seismic activity and
faults for several power plants in Italy,studies for nuclear power
plant siting in Iran,evaluations of dams and dam sites in North and
South America,and mapping active faults for land-use planning in Managua,
Nicaragua.He has completed studies of seismic and geologic hazards
in offshore areas of California,Alaska,and the Caribbean.
GEB 1-79
George E.Brogan
Woodward-Clyde Consultants
page 2
His experience in siting critical facilities includes studies for domestic
and foreign nuclear power plants.He managed field and office studies
that identified potential nuclear power plant sites along the Southern
Persian Gulf and Gulf of Oman for the Atomic Energy Organization of
Iran (AEOI).After the siting studies were completed,he managed field
studies of 5 of the sites;these studies were used as a basis by AEOI
for selecting t~e favored site on the Persian Gulf.In addition to
managing the Iranian siting studies,Mr.Brogan has provided high-level
guidance in developing the approach and philosophy to be used in nuclear
power plant siting studies in California for Pacific Gas and Electric
Company (PG&E),and in Washington and Oregon for Washington Public
Power Supply System (WPPSS).
Mr.Brogan has managed studies for siting other critical facilities,
including siting of a proposed Liquefied Natural Gas (LNG)Import
Terminal Site in California.Those studies were conducted for the
California Coastal Commission,a California State agency that regulates
development in coastal areas.Both onshore and offshore areas were
considered,and methodologies were developed to screen coastal California
for acceptable areas,and to identify positive and negative attributes
of individual sites.Field studies were conducted in response to the
methodologies that were developed,which resulted in ranking of 10
sites and selecting a favored onshore site and a favored offshore site.
Mr.Brogan has become a recognized leader in evaluating earthquakes
and fault activity.He has convened a Geological Society of America
Penrose Conference on that topic,and is an adviser to thp u.S.Geological
Survey Earthquake Hazard Reduction Program.He has taught graduate
and undergraduate courses in geology and earthquake engineering,has
lectured for many universities and professional organizations,and
was selected as Woodward-Clyde Consultants'Young Professional in
Geotechnical Practice in 1975.In his present position,Mr.Brogan
is in responsible charge of geological,seismological,and geophysical
studies within the Southern California offices of Woodward-Clyde Consultants.
AFFILIATIONS
American Association for the Advancement of Science
American Association of Petroleum Geologists
American Geological Institute
American Geophysical Union
American Society of Photogrammetry
Association of Engineering Geologists
Earthquake Engineering Research Institute
Geological Society of America
International Association of Eng.ineering Geology
Seismological Society of America
Sigma Xi
GEB 1-79
George E.Brogan
PUBLICATIONS
Woodward-Clyde Consultants
page 3
Mr.Brogan has authored or co-authored more than 30 professional
publications that have appeared in numerous scientific and engineering
journals and proceedings of conferences and symposia.These publications
include studies of the effects of recent earthquakes,case histories
of studies of faulting and seismicity in many localities,and philosophical
discussions regarding mitigation of geological hazards.A complete
list of Mr.Brogan's publications will be provided upon request.
GEB 1-79
Ulrich Luscher
EDUCATION
Woodward·Clyde Consultants
project management
geotechnical engineering
frozen soil engineering
performance and instru-
mentation engineering
-
Massachusetts Institute of Technology,Cambridge:Sc.D.,Civil Engineering,
1963
Massachusetts Institute of Technology,Cambridge:M.S.,Structures,1959
Swiss Federal Institute of Technology,Zurich,Switzerland:B.S.,
Civil Engineering,1956
REGISTRATION
Registered Civil Engineer:California
Registered Professional Engineer:Massachusetts
PROFESSIONAL HISTORY
Woodward-Clyde Consultants,San Francisco,California,Principal,1974-
date;Associate.and Project Engineer,1967-1974
Massachusetts Institute of Technology,Department of Civil Engineering,
Assistant Professor,Soil Mechanics,1963-1967
Massachusetts Institute of Technology,Instructor and Research Engineer,
1959-1963
Vevey Iron Works,Switzerland,Design Engineer,1957
REPRESENTATIVE EXPERIENCE
Dr.Luscher's professional activities over the last 22 years have covered a
broad range of applied geotechnical projects with ever increasing responsi-
bility.At present,he is in charge of a group which conducts or manages
large,often interdisciplinary projects for major industrial and governmental
clients.He has recently been responsible for a site evaluation for an LNG
plant,a foundation investigation for a nuclear power plant,offshore site
evaluations,and measurement and appraisal of building vibrations.He has
also headed several recent projects related to hazardous waste storage ponds.
As the principal responsible for a field measurement group,he has overseen a
number of research and development studies related to development of energy
resources and including topics such as mining subsidence,mine dewatering,
geothermal subsidence measurement,core recovery,and in-situ permeability
measurement.He has also headed several applied field instrumentation and
monitoring projects.Finally,he is responsible for the extensive WCC soil
and rock mechanics laboratory in Oakland,California.
Since mid-1977,Dr.Luscher
gas pipeline across Alaska.
review of the existing data
and a large laboratory test
UL 7-79
has managed several studies for the proposed chilled
The work has related to trench blasting tests,a
base for the project,seismic fault investigations,
program.
Ulrich Luscher
Woodward·Clyde Consultants
page 2
From 1970 to 1976,Dr.Luscher was involved full-time in the Trans-Alaska
oil pipeline project,leading a group of Woodward-Clyde Consultants'personnel
engaged in evaluating geotechnical aspects of the pipeline system.The work
included the following major areas:(1)Design of the pipeline support system,
including development and application of criteria to evaluate the need for above-
ground construction;(2)Development of design criteria and mile-by-mile design
information for vertical support members of the above-ground pipeline;this
task included field tests on prototype support members;(3)Geotechnical field
engineering during construction,and development of guidelines for design
changes in response to field conditions different from those assumed in the
design;and (4)Preparation of surveillance and monitoring manual for use during
pipeline operation.
Before 1970,Dr.Luscher acquired extensive experience in many phases of geo-
technical engineering including foundations,earth retaining structures,land
development,earth structures and underground conduits.He also worked on
several projects involving nuclear power stations and the effects of earthquakes
and other dynanilc loads.
Dr.Luscher has also conducted projects involving foundation instrumentation,
performance monitoring,and correlation between observed and predicted founda-
tion performance.He has done research on the interaction of soil and under-
ground structures and the failure conditions of foundations under static and
dynamic loads.
AFFILIATIONS
An~rican Society of Civil Engineers
International Society of Soil Mechanics and Foundation Engineering
Structural Engineers Association of Northern California
PUBLICATIONS
The following is a partial list of publications.A full list will be provided
on request.
"Geotechnical Issues and Answers During Construction of the Trans-Alaska Pipe-
line,"with H.P.Thomas,Paper No.78-Pet-66,ASME Transaction,1979.
"Pipe-Soil Interaction,Trans-Alaska Pipeline,"with H.P.Thomas and J.A.Maple,
ASCE Specialty Conference on Pipelines in Adverse Environments,New Orleans,
Jan.1979.
"Geotechnical Aspects of Trans-Alaska Pipeline,"with W.T.Black and K.Nair,
Proceedings,ASCE,Vol.101,No.TE4,Nov.1975.
"Thaw Consolidation of Alaskan Silts and Granular Soils,"with S.S.Afifi,
Permafrost:North American Contribution to 2nd International Conference,1973.
UL 7-79
Lloyd S ..Cluff
EDUCATION
University of Utah,Salt Lake City:
University of Utah,Salt Lake City:
REGISTRATION
Woodward·Clyde Consultants
seismicity and seismic
geology
earthquake engineering
environmental geology
engineering geology
B .S .,Geology
Graduate studies in Engineering Geology
-
-
Geologist:California
Certified Engineering Geologist:California
PROFESSIONAL HISTORY
Woodward-Clyde Consultants,San Francisco,California,Principal,Chief
Engineering Geologist,Vice President and Director,1971-date;Asso-
ciate and Chief Engineering Geologist,1965-1971;Staff Geologist,1960-1965
University of Nevada,Reno,Nevada,Visiting Associate Professor of Geology,
1968-1973
Lottridge Thomas &Associates,Salt Lake City,Utah,Geologist,1960
E1 Paso Natural Gas Company,Salt Lake City,Utah,Junior Geologist,1957-1959
University of Utah,Salt Lake City,Utah,Teaching Assistant,1958-1960
REPRESENTATIVE EXPERIENCE
As V.ice President and Chief Engineering Geologist,Mr.Cluff is responsible
for all technical and administrative functions related to geologic,seismo1ogic,
and geophysical investigations,explorations,and evaluations.Types of pro-
jects under Mr.Cluff's direction include nuclear reactor siting studies,
active fault and earthquake hazard and risk evaluations,geologic hazard evalua-
tions,seismic safety studies,and land-use planning with regard to geologic
and earthquake hazards.Mr.Cluff also directs geologic and earthquake studies
relating to dams,bridges,tunnels,pipelines,highways,urban development,
LNG facilities,industrial sites,oil field operations,offshore developments,
groundwater development,and aggregate and quarry sites.
In March,1978,Mr.Cluff was elected to the National Academy of Engineering.
He served in 1976 and 1977 on the Newmark Panel,a panel of experts called to
advise the u.s.Geological Survey,National Science Foundation,and the Presi-
dent regarding the national program for earthquake prediction and hazard
mitigation.He serves on the Earthquake Programs Advisory Panel of the U.S.
Geological Survey and is a consultant to the Office of Science and Technology
Policy,Working Group on Earthquake Hazards Reduction.He is a member of the
National Academy of Sciences'Committee on Seismology,and serves on their
Subcommittee on seismo1ogic and geologic considerations in the safe siting of
critical facilities.He recently served on an International Strong Motion
LSC 8-78
Lloyd S.Cluff
Woodward·Cycie Consultants
page two
-
-
Arrays Committee of the International Associations of Earthquake Engineering
and of Seismology and Physics of the Earth's Interior.He has served as con-
sultant to the U.S.Atomic Energy Commission,Oak Ridge National Laboratory,
regarding active faulting and earthquake effects on nuclear reactor safety.
As a member of the State of California's Task Committee on Seismic Hazards
from State-Owned/Occupied Structures,Mr.Cluff is involved in thedefini-
tion of standards for the evaluation of seismic risk.He was a member of
the Stanford Research Institute Oversight Committee on Earthquake Predic-
tion,and the State of California Energy Resources Conservation and Develop-
ment Commission Advisory Panel on earthquake and geologic hazards in
California.
Mr.Cluff has made more than 15 post-earthquake evaluations of the geologic
effects of damaging earthquakes throughout the world as a post-earthquake
evaluation team member for the Earthquake Engineering Research Institute,the
International Association of Engineering Geologists,the California Seismic
Safety Commission,and the California Governor's Earthquake Council.
Since 1967,Mr.Cluff has served as consultant to the Venezuelan Presidential
Earthquake Commission.From 1966 to 1970,he served as consultant to the
State of Utah Governor's Earthquake Council and to the Utah Geological and
Mineralogical Survey regarding active faulting,earthquake,and geologic
hazards in Utah.
From 1968 to 1973,he served as a member of the Consulting Board of the San
Francisco Bay Conservation and Development Commission,Earthquake Engineering
Criteria Review Board.In 1969,he served as a member of the Special Panel
of Consultants to the President and the Secretary of the Interior for the
Santa Barbara oil spill,and was responsible for reviewing earthquake prob-
lems in that area.
As a member of the International Consulting Board for the International Atomic
Energy Agency in Vienna,Mr.Cluff advised on geologic,seismo10gic,and
earthquake engineering problems associated with siting nuclear power reactors
in foreign countries.He has served as a consultant to the atomic energy
commissions of the governments of Mexico,Chile,Italy,and Iran,regarding
active faulting,earthquakes,and geologic hazards with respect to siting
nuclear reactors.Since 1970,he has served as consultant to Ente Naziona1e
Per L'Energia E1ettrica,Milan,Italy,on geologic and earthquake hazards
with respect to siting fossil fuel power plants in Italy.He has also served
as consultant to Ente Naziona1e Per L'Energia Elettrica,Rome,Italy,regard-
ing active faulting and earthquake problems in siting nuclear reactor power
plants in Italy.He has served as consultant to Comision Federal de E1ectri-
cidad,Mexico,regarding dam safety from active faulting and earthquakes.
LSC 8-78
Lloyd S.Cluff
Woodward·CIyde Consultants
page three
He served as a member of the State of California Joint Committee on Seismic
Safety,Advisory Group on Land Use Planning to Minimize Earthquake Risk.
Since 1970,Mr.Cluff has served as a member of the UNESCO Consulting Board
in Paris for "seismic phenomena associated with the filling of large reser-
voirs."He has served as consultant to the U.S.Corps of Engineers,Vicks-
burg research facility,and the U.S.Bureau of Reclamation regarding active
faulting and earthquake effects on dams.
Mr.Cluff is a member of the Board of Directors of the Earthquake Engineer-
ing Research Institute.He was President of the Association of Engineering
Geologists,1968-1969.He also served as Vice President of the International
Association of Engineering Geologists,1970-1974.He is Chairman of the
International Association of Engineering Geology Commission,studying world-
wide seismic phenomena.
Mr.Cluff is listed in Engineers of Distinction (1970)and American Men of
Science (1975).
AFFILIATIONS
National Academy of Engineering
Association of Engineering Geologists
Earthquake Engineering Research Institute
Geological Society of America
International Association of Engineering Geologists
Seismological Society of America
Structural Engineers Association of Northern California
Utah Geological Association
PUBLICATIONS
Mr.Cluff has authored and co-authored more than 50 technical papers on
subjects relating to geology,seismology,and engineering.These papers
have been published in national and international journals,and proceedings
of conferences and international meetings.
LSC 8-78
I.M.IdriB.
EDUCATION
Woodward·CIyde Consultants
earthquake engineering
soil mechanics and foundation engineering
numerical techniques and computer applications
University of California,Berkeley:Ph.D.Civil Engineering,1966
California Institute of Technology:M.S.Civil Engineering,1959
Rensselaer Polytechnic Institute:B.C.E.,civil Engineering,1958
REGISTRATION
Civil Engineer:California
PROFESSIONAL HISTORY
Woodward-Clyde Consultants,San Francisco,California,Principal and Vice
President,1974-date
Woodward-Clyde Consultants,San Francisco,California,Director,1975-date
Stanford University,Department of Civil Engineering,Consulting Professor,
1977-date
Woodward-Clyde Consultants,Oakland,California,Associate,1969-1974
University of California,Berkeley,Department of Civil Engineering,Associate
Research Engineer,1966-1975
Consultant to several architect-engineers and other firms,1966-1969
Dames &Moore,San Francisco,California,Senior Soils Engineer,1968-1969
University of California,Berkeley,Department of Civil Engineering,Lecturer
in Soil Mechanics,1967-1968
Dames &Moore,Los Angeles,New York and San Francisco,Field Engineer to
Project Manager,1959-1966
Moran,Proctor,Meuser &Rutledge,Field Engineer,New York,New York,
Sununer,1958
REPRESENTATIVE EXPERIENCE
Dr.Idriss has been engaged in the practice of soil mechanics and foundation
engineering since 1958 and has worked on foundation investigations for land
~evelopments,industrial buildings,power plants,earth dams,offshore
structures and other facilities.Since 1964,he has also been engaged in
research and applications pertaining to:the seismic response of soil
masses and soil structures;evaluation of the failure potential of soils;
soil material properties during cyclic loading;soil-structure interaction
during earthquakes;and characteristics of ground motions.As a result of
this research,he has developed and co-developed several analytical and
empirical procedures for the evaluation of the behavior of soil masses during
earthquakes.Recent consulting assignments have included seismic investigations
for earth and rockfill dams,sites for nuclear power plants,high-rise
buildings,offshore platforms,and industrial facilities,and applied research
studies.
IMI ]-79
I.M.Idrlss
Woodward·Clyde Consultants
page 2
-
Dr.Idriss is director of geotechnical earthquake engineering studies for
the Western Region of Woodward-Clyde Consultants.He has conducted and
directed such studies for over 25 earth and rockfill dams in California,
Alabama,North Carolina,Tennessee,and in Latin America.He has also
conducted and directed earthquake engineering studies (including ground-
motion characterization,assessment of liquefaction potential,evaluation
of soil-structure interaction,cyclic soil characterization)at over 20
nuc.lear plant sites in the USA,Europe and the Middle East.Other projects
for which he has conducted and directed geotechnical earthquake engineering
studies include offshore platforms in California,Alaska,and New Zealand,
and waterfront facilities,fossil plants,land developments in California,
Idaho,Alaska,New Jersey,Texas,Italy,Puerto Rico,Iran,Nicaragua,
Venezuela and other locations.Among the more recent applied research and
non-site specific studies he has been engaged in are the following:
Soil-structure interaction studies for GESSAR and for General Electric's
Standard Plant (1973-date);assessment of behavior of marine clay sediments
during earthquake loading conditions (l973-date);assessment of behavior of
marine clay sediments during wave loading conditions (1976-date);behavior
of soil-pile-structure systems during earthquakes (1976-date);soil-structure
interaction studies and correlations with model field tests (1976-1978);
probabilistic and deterministic assessment of ground motions in Southern
California for small and moderate earthquakes (1976-date);and Offshore
Alaska Seismic Exposure studies (1977-date).
Recent Applied Research Activities:Since early 1975,Dr.Idriss has been
conducting research related to the nonlinear behavior of soils under cyclic
loading conditions.The results of this research have been applied to
assessing performance of soft sediments during earthquakes.Other research
activities in which Dr.Idriss has been engaged relate to:significant
duration of earthquakes,simplified procedures for assessment of seismic
soil-structure interaction,and probabilistic review and assessment of
recorded ground motions and associated spectra.
HONORS
Norman Medal,ASCE,1977
Walter L.Huber Civil Engineering Research Prize,ASCE,1975
Woodward Lecture,'Woodward-Clyde Consultants,1973
J.James Croes Medal,ASCE,1972
The Thomas A.Middlebrooks Award,ASCE,1971
Chi Epsilon (Honorary Member,Rensselaer Polytechnic Institute Chapter)
Tau Beta Pi
Sigma Xi
IMI 3-79
I.M.Idrls.
SPECIAL ASSIGNMENTS
Woodward-Clyde Consultants
page 3
1966-date:invited lecturer at various universities in the United States,
Latin America,Canada,Europe,and the Middle East
1971-date:invited lecturer at specialty conferences and special courses
in the United States,Latin America,and Europe
1975-date:consultant to the International Atomic Energy Agency,Vienna;
participated in preparation of IAEA's Safety Guide on "Seismic Analysis
and Testing of Nuclear Power Plants"
1970-1976:consultant to the Government of Italy on nuclear reactor safety
related to earthquake effects
1974-1977:Member,Subcommittee on Ground Motions and Site Effects,Applied
Technology Council
AFFILIATIONS
American Society of Civil Engineers
Member:Publications Comndttee,Geotechnical Division;
Nuclear Structures and Materials Committee,Structural Division
(Chairman,Ad Hoc Group on Soil-Structure Interaction)
Earthquake Engineering Research Institute
Seismological Society of America
Structural Engineers Association of Northern California
Member:Seismology Committee (Soil-Structure Interaction
Subcommittee;Chairman 1971-1972;1977-1979)
U.S.Committee of the International Commission on Large Dams
American Petroleum Institute
PUBLICATIONS
Dr.Idriss has authored or co-authored over 60 technical papers and research
reports on subjects relating to the geotechnical aspects of earthquake
engineering (seismic response of soil deposits;earth structures including
slopes and earth and rockfill dams;dynamic soil material properties;
liquefaction;soil-structure interaction;and probabilistic and deterministic
assessment of characteristics of ground motions.)These papers have been
published in the Journals of the Geotechnical Engineering Division,the
Structural Engineering Division and Proceedings of Specialty Conferences of
the American Society of Civil Engineers;Bulletin of the Seismological
Society of America;International Journal of Earthquake Engineering and
Structural Dynamics;Proceedings of World Conferences on earthquake
engincer.ing,Offshore Technology Conference,and proceedings of other
international engineering meetings.
IMI 3-79
Woodward-Clyde Consultants
Robert B.Forbes senior project advisor
consultant
EDUCATION
University of Washington:Ph.D.,Geology,1959
University of Washington:B.S.,Geology,1948
PROFESSIONAL HISTORY
senior Geologic Consultant,Geophysical Institute,University of Alaska,1976-
present
Professor of Geology,Geophysical Institute and Geology Department,University
of Alaska,1970-1976
Visiting Research Geologist,Alaskan Geology Branch,USGS,Menlo Park,California,
1969-1970.(Temporary app:>intment;Sabbatical Leave academic year 1969-70)
Professor and Head,Geology Department,University of Alaska Geology Dept.and
Geophysical Institute,1965-1969
Associate Professor of Geology,Geophysical Institute and Geology Department,
University of Alaska,1964-1965
Visiting Research Professor in Petrology,Geophysical Institute University of Tokyo,
Tokyo,Japan (NSF Science Faculty Fellowship),1963-1964
Associate Professor of Geology,Geophysical Institute and Geology Dept.,University
of Alaska,1961-1963
Assistant Professor,Geology Department,University of Alaska,1959-1961
Research Associate,Department of Geology,University of Washington,1957-1959
Assistant and Acting Chief,Research Branch,Office of Research Develo flIlent,OQMG,
Washington,D.C.,1955-1957
Department of Army Expeditions project Supervisor,1953-1955
Chief,Field Observation Branch,OQMG,Department of Army,Washington,D.C.,
1952-1953
Consultant,Mountain Environment Project,Department of Army,Washington,D.C.,
1951-1953
Geologist and Executive Officer,Juneau Ice Field Research Project,(spring-sulnmer)
1949-1950
HONORS
Vice President,Section of Volcanology,Geochemistry and Petrology,American
Geophysical Union,1970-1972
National Science Foundation Science Faculty Fellow in Geology (Geological Institute,
Tokyo University),1963-1964
Department of Army Outstanding Performance Award (Special award for Antarctic
research),Jan.,1957
Robert B.Forbes
PROFESSIONAL ORGANIZATIONS
Woodward-Clyde Consultants
Page 2
Fellow,Geological Society of America
Fellow,Arctic Institute of North America
Fellow,American Association for the Advancement of Science
Member,American Geophysical Union
Member,American Association of Petroleum Geologists
Member,Signma xi
Member,American Polar Society
PRESENT RESEARCH INTERESTS
Petrology and geochemistry of igneous and metamorphic rocks,with current emphasis
on andesitic volcanism and the petrology of blueschist and eclogite facies metamorphic
rocks;volcanology,including geophysical and geochemical studies of Alaskan volcanoes;
exfiloration and utilization of Alaskan geothermal and uranium resources.
PUBLICATIONS
Dr.Forbes has plblished or presented over 95 papers and reFOrts.A comfilete list of
these can be submitted on request.
-
Norma E.Biggar
EDUCATION
Woodward.CIyde Consultants
geology
-
University of Alaska,Fairbanks:M.S.,Geology,1974
Antioch College,Yellow Springs,Ohio:B.A.,Geology,1970
REGISTRATION
Registered Geologist:California
Certified Engineering Geologist:California
PROFESSIONAL HISTORY
Woodward-Clyde Consul tants,San Francisco,California,Staff Geologist to
Project Geologist,1973-date
Geophysical Institute,University of Alaska,Research Assistant,1971-1973
Wright State University,Teaching Assistant,Department of Geology,1971
Dr.Ronald G.Schmidt,Consulting Geologist,Yellow Springs,Ohio,Drafts-
person,1971
REPRESENTATIVE EXPERIENCE
Ms.Biggar has served as the project geologist for the active fault identi-
fication study for the proposed Alcan gas pipeline in Alaska;and for the
geological and seismological investigations of the New Melones Dam site in
California.
She served as technical editor for the Woodward-Clyde Consultants'book,
"Age Dating of Geologic Materials",in addition to researching and compiling
many of the age-dating discussions presented in the book,and is presently
preparing a manuscript of the book for publication.Since joining Woodward-
Clyde,she has also been involved in regional geologic studies for the siting
of a proposed LNG plant at Yakutat,Alaska,nuclear reactors in the Persian
Gulf of Iran,Italy,and the Central Valley of California,and the detection
of active faults for the Trans-Alaska pipeline project.
An overall geologic study of the Chena Hot Springs area near Fairbanks,
Alaska was the topic of Ms.Biggar's Master's Thesis.This investigation
included a 35-square mile mapping project of the grani tic and metamorphic
uni ts in the vicini ty of the thermal springs,and geochemical,geophysical and
ground temperature studies in the thermal area.
AFFILIATIONS
Geological Society of America
Association of Women Geoscientists
Association of Engineering Geologists
NEB 6-78
Norma E.Biggar
PUBLICATIONS
Woodward-Clyde Consultants
page 2
"Alaska's geothermal resource potential",with R.B.Forbes,The Northern
Engineer,V.5,No.1,1973.
"Identification of distinguishing characteristics of late Quaternary faults
in the Western Sierran foothills,California",with R.F.Harpster and C.L.
Taylor,Abstracts,Earthquake Notes,V.49,no.1,pp.88-89,1978.
"Evaluation of Quaternary faulting in colluvium and buried paleosols,Western
Sierran Foothills,California",with W.D.Page,F.H.Swan III,R.Harpster
and L.S.Cluff,Abstracts with Programs,Cordilleran Section,Geological
Society of America,V.10,no.3,p.141,1978.
NEB 6-78
William U.Savage
EDUCATION
Woodward·Clyde Consultants
seismology
geophysics
seismic geology
-
--
University of Nevada,Reno:Ph.D.,Seismology,1976
University of Nevada,Reno:M.S.,Seismology,1971
University of Washington:National Science Foundation Graduate Fellow,
Geophysics,1966-1968
University of Oregon:B.S.,Physics,1966
PROFESSIONAL HISTORY
Woodward-Clyde Consultants,San Francisco,California,Senior Project
Seismologist,1974-date
United States Geological Survey,Menlo Park,California,Research
Associate,1973-1974
University of Nevada,Reno,Seismological Research Assistant,1969-1973
REPRESENTATIVE EXPERIENCE
Dr.Savage has applied his seismological research experience and training
to a large number of projects at Woodward-Clyde Consultants.He has con-
ducted historical seismicity evaluations,seismotectonic interpretations,
and seismic safety analyses for high-rise buildings,thermal and nuclear
power plant sites,offshore oil developments,and other critical engineer-
ing projects,both in the United States and overseas.Dr.Savage has
recently completed several major investigations of microearthquake occur-
rence as related to the development of seismic design criteria for major
projects.These projects,in the United States,the Middle East,and
Latin America,involved the design and installation of both portable and
permanent telemetered arrays of field microearthquake recorders,the anal-
ysis of the resulting data,and the interpretation of the results leading
to seismic safety ain design information.These studies have been signi-
f icant in understanding earthquake hazards in complex geologic env iron-
ments.Dr.Savage is leading the Woodward-Clyde Consultants program in
developing additional capabilities in microearthquake instrumentation and
applications.
During the past several years,Dr.Savage has participated as a key member
representing the fields of seismology on several interdisciplinary project
teams.These projects have involved siting studies and safety analyses
for the major dams of Auburn,Cal ifornia,the Coca River,Ecuador,and the
Chulac and Xalala projects,Guatemala,and for the nuclear power plants at
Hanford,Washington,Humboldt Bay,California,and San onofre,California,
and pruposed plants at Stanislaus,California,and in SOuthern Iran.Dr.
Savage has directed field studies and data analyses for seisr~logical
aspects of the projects and has worked with other technical experts in the
earth sciences and engineering to synthesize and integrate the results of
the investigatioI~performed and to ~utually develop and apply the method-
ologies leading to specific engineering results.
WUS 6-79
William U.Savage
Woodward·Clyde Consultants
page 2
Dr.Savage has recently completed a study of the seismicity of the Alaskan
Interior for the proposed Alcan gas pipeline.In this study,detailed
analyses of the microearthquake data along and east of the Denali fault
were carried out to assess the location,level of activity,and sense of
movement of potentially active faults.
While with the U.S.Geological Survey's National Center for Earthquake
Research as a Postdoctoral Research Fellow,Dr.Savage participated in
studies of historical seismicity,microearthquake seismicity,and seismic
velocities pertinent to earthquake prediction.At the University of
Nevada,Dr.Savage helped supervise the installation of a statewide tele-
metered seismic network and studied the statistical occurrence features of
earthquake activity.
AFFILIATIONS
American Association for the Advancement of Science
American Geophysical Union
Seismological Society of America
Geological SOciety of America
Earthquake Engineering Research Institute
PUBLICATIONS
Dr.Savage has authored numerous reports and portions of reports ranging
from brief summaries of site-related observations to lengthy presentations
of the technical results of major studies and to regulatory agency docu-
mentation such as Preliminary Safety Analysis Reports for the U.S.Nuclear
Regulatory Commission.In addition,much of his work has received peer
review within the academic and professional community through presenta-
tions at scientific meetings and the publication of technical articles in
professional journals.A complete list of publications is available upon
request.Dr.Savage has also presented technical seminars and public lec-
tures both locally and abroad on topics related to earthquake hazards,
current seismological research,and engineering seismology.
WUS 6-79
Maurice S.Power
EDUCATION
Woodward·Clyde Consultants
soil mechanics
foundation engineering
earthquake engineering
University of California,Berkeley:M.S.,Soil Mechanics,1962
Stanford University,Stanford:B.S.,Civil Engineering,1961
REGISTRATION
Civil Engineer:California
PROFESSIONAL HISTORY
Woodward-Clyde Consultants,San Francisco,California,Staff Engineer to
Associate,1966-date
Naval Air Station,Grosse Ile,Michigan,Assistant Public Works Officer,
1963-1965
Harding,Lawson &Associates,San Rafael,California,Field and Labora-
tory Engineer and Staff Engineer,summers 1960-1962
REPRESENTATIVE EXPERIENCE
Mr.Power has been engaged in analysis,design,planning and project
management for a wide range of foundation engineering and earthquake engi-
neering studies.Since 1970,he has worked primarily in earthquake engi-
neering applications,including liquefaction potential evaluations,char-
acterization of soil dynamic properties,ground response analyses,earth-
quake ground motion studies,soil-structure interaction analyses,and
seismic stability evaluations of slopes and dams.
Representative projects include:
Earth arrl Rockfill Dams:Upper San Learrlro Dam (San Learrlro,California);
San Pablo Dam (San Pablo,California);Chabot Dam (near Oakland,Califor-
nia);five proposed earth and rockfill dams (near Raleigh,North Caro-
lina);two proposed earth dams (near Columbia,South Carolina);two pro-
posed earth dams (near Walnut Creek,California);and Watauga Dam
(Tennessee).
Nuclear Plant Sites:Summer Plant (near Columbia,South Carolina);
Shearon lIarris Plant (North Carolina);South Texas project (near Bay City,
Texas);X21-X22 Nuclear Station (northeastern Tennessee);X24-X25 Nuclear
Station (Tishomingo County,Mississippi);proposed Stanislaus Plant
(central California);Humboldt Bay Plant (Humboldt Bay,California);San
Onofre Nuclear Generating Station (Southern California).
Industrial Facilities and Building Sites:projects include foundations
and seismic investigations for many types of facilities including:
assessment of liquefaction potential and design response spectra for off-
shore platforms Maui A and Maui B in New Zealand;foundation and seismic
studies for the Port of Oakland,California Middle Harbor Terminal
(wharves,dikes and fills),preliminary characterization of ground motions
MSP 4-79
Maurice S.Power
Woodward·Clyde Consultants
page 2
and evaluations of liquefaction potential for a proposed LNG facility in
Yakutat,Alaska;soil and foundation studies for the Trans Alaska
pipeline;earthquake ground motion studies for proposed offshore oil plat-
forms in the Santa Barbara Channel,California;preliminary evaluations of
geotechnical conditions and geologic hazards for offshore platforms on the
Kodiak outer continental shelf,Alaska;geotechnical planning and feasi-
bility study for offshore guyed tower platforms;applied research on the
behavior of offshore soil-pile-structure systems during earthquakes.
Other representative projects include:characterization of earthquake
ground motions and ground motion probability studies for the proposed
Auburn Dam,California;evaluation of the causes of damage to the Joseph
Jensen Water Filtration Plant (Los Angeles,California)during the 1971
San Fernando earthquake;preparation of input for the seismic safety ele-
ment,City of Fremont,California;foundation studies and seismic evalu-
ations for the Loma Linda veterans Administration Hospital (Loma Linda,
California);evaluation of liquefaction potential of gravels beneath sand
and gravel pits proposed to be used for solid waste disposal (Pleasanton,
California);evaluations of expansive soil effects on residential housing
in California,Colorado,Texas and Alabama for the Federal Housing Admini-
stration;earthquake engineering and wave loading studies for the proposed
Southwest Ocean Outfall,offshore san Francisco,California;seismic soil-
structure interaction studies for General Electric's Standard Nuclear
Plant.
AFFILIATIONS
American Society of Civil Engineers
Earthquake Engineering Research Institute
Seismological Society of America
PUBLICATIONS
"A Simplified Procedure for Developing Interaction Response Due to Vari-
-ations in Soil Properties,"paper presented at the ASCE Structural Divi-
sion Specialty Conference on Methods of Structural Analysis,Madison,Wis-
consin,with K.Sadigh,C-Y.Chang,and T.Udaka,August 1976.
"Soil Response Considerations in Seismic Design of Offshore Platforms,"
Journdl of Petroleum Technology,with I.M.Idriss and R.Dobry,March
1976.
"A Study of Attentuation of Ground Motion Parameters for Moduate Magnitude
Earthquakes,"sixth European Conference on Earthquake Engineering,
Dubrovnik,Yugoslavid,with K.Sadigh and R.R.Youngs,September 1978.
"Peak lior izontal ani Vertical Accelerations,Velocit ies,and Displdcements
on Deep Soil Sites for Moderately Strong Earthqudkes,"Proceedings,Second
Interndtional Conference on Microzonation,San Francisco,California,with
K.Sadigh and R.R.Youngs,November 1978.
MSP 4-79
Woodward-Clyde ConsuRants
RELEVA~T EXPERIENCE AND QUALIFICATIONS
Woodward·Clyde Consultants
RELEVANT EXPERIENCE
General
Woodward-Clyde Consultants is a nationwide consulting firm
practicing in the general fields of geotechnical engineering
and environmental assessment.We offer such services as
earthquake eng ineering ,site selection,eng ineering ,geo-
logy,se ismology,env i ronmental impac t assessment,and
decision analysis.
We have a staff of about 800 professional and support
personnel,three-quarters of whom are graduate engineers and
sc ientists or skilled technicians.Approximately 350 hold
advanced degrees in the physical sciences (chemistry,
geology,geophysics,hydrology,meteorology,physics,and
physical oceanography),engineering (civil,geotechnical,
mechanical,nuclear,chemical,and sanitary),the natural
sciences (terrestrial and aquatic ecology and biological
oceanography),and the social sciences (economics,land-use/
urban planning,sociology).
WCC has conducted studies for a large number of projects to
evaluate the characteristics of site ground motions during
earthquakes and the potent ial for se ism ically-induced
failure of in-situ soil deposits and earth and rockfill
dams.Several of these projects are in Alaska.The attach-
ed table summari zes the earth and rockf ill dams for which
seismic stability evaluations have been made by WCC.Our
scope of work for several of these dams is described in the
project summaries following this section.The studies have
ranged from regional to site-specific evaluations,and from
feas ib il i ty to final des ign stud ies.rfhe Of fshore Alaska
Seismic Exposure Study (OASES),which is summarized in the
attachments,is particularly relevant to and useful for the
probabilistic assessments of earthquake ground motions that
will be made for the Susitna project.
Woodward-Clyde Consultants
QUALIFICATIONS AND EXPERIENCE/GEOLOGY-SEISMOLOGY-GEOPHYSICS
Woodward-Clyde consultants maintains a talented,multidisci-
pl inary g roup of earth sc ientis ts engaged in geolog ical ,
seismological,and geophysical investigations.The Director
of the Geology-Seismology-Geophysics Professional Group is
Lloyd S.Cluff,an internationally recognized expert in
eng ineering geology and seismic geology.Until recently,
the Ch ief Se ismolog ist wi th Woodward-Clyde Consul tants has
been the late Dr.Don Tocher,a recognized authority in the
fields of seismology and engineering seismology.The
Geology-Seismology-Geophysics Group is composed of more than
125 professionals and is based in San Francisco,California.
This group provides Woodward-Clyde Consultants with un-
matched depth of experience and diverse capabilities in the
earth science.
The Geology-Seismology-Geophysics Professional Group brings
to the Susitna project,many hundreds of person-years
involved with studies of regional seismicity,active fault-
ing,and seismic hazard evaluation for major eng ineering
projects.These past and present studies are world-wide in
distribution and include extensive experience in Alaska.
The fault study completed by Woodward-Clyde Consultants for
Alyeska Pipeline Service Company in 1974 was a landmark
investigation that established design parameters for active
faul t crossings and improved the knowledge of earthquake
sources for the region of the Alyeska pipeline route.The
area examined in detail in the study for Alyeska borders the
study area for the proposed Susi tna project.The Alyeska
study demonstrated that the Woodward-Clyde Consultants
project team has the capability to deliver the necessary and
appropriate results of complex investigation carried out in
Alaskan field conditions.
-
-
Woodward-Clyde Consultants
In addition,we have performed regional fault and seismicity
studies for Alaska Outer Continental Shelf sites;the
proposed NWAP gas pipeline in Alaska;regional and local
fault,seismicity,and geophysical studies for marine
terminal facilities proposed for Yakutat,Alaska;numerous
seismici ty and faul t evaluat ions for nuclear power plant
sites in California,Washington,Arizona,New Mexico,Texas,
New York,Nicaragua,and Iran;regional seismicity and
faul t stud ies for numerous large dams;and faul t mapping
and earthquake recurrence evaluations in Alaska,California,
Nevada,Arizona,Utah,Idaho,washington,Italy,Venezuela,
Argentina,Iran,Nicaragua,Guatemala,Colombia,and Ecua-
dor.The experience gained in these investigations has
resulted in the development of methodologies to effectively
acquire,analyze,evaluate,document,and defend varied data
analyses and interpretations for major engineering projects
under close scrutiny of regulatory agencies.The attached
descriptions illustrate the experience and services we have
provided in some of our past projects.
QUALIFICATIONS AND EXPERIENCE -EARTHQUAKE ENGINEERING
In its Western Region,WCC has a permanent group engaged in
earthquake engineering studies.The director of the Earth-
quake Engineering Group is Dr.I.M.Idriss,who is an
internationally-known expert in this field.A staff of 13
engineers currently comprises the Earthquake Engineering
Group in the San Francisco office of WCC's western Region.
An additional 3 engineers in the Earthquake Engineering
Group are located in our Orange,California office.This
group of eng ineers prov ides a depth of experience and
capabilities for a variety of earthquake engineering appli-
cations.
Woodward-Clyde Consultants
The types of services engaged in by the Earthquake Engineer-
ing Group include:a)characterization of earthquake ground
motions for design purposes;b)characterization of soil
dynamic properties and cyclic strength characteristics;c)
nonlinear analyses of the response of soil deposits to
earthquakes,including development of improved procedures
for analyses and material characterization;d)evaluations
of the potential for seismically induced ground fail ures,
including liquefaction and slope instability and ground
deformations,and development of remedial measures;e)
dynamic analyses of soil-structure interaction.
For use in characterizing ground motions and conducting
dynamic response analyses,WCC has a data bank on computer
files of recorded earthquake ground motions.The motions on
file include all those digitized and processed at the
California Institute of Technology and many other records
from Alaska,Japan,South America and other locations
acquired,digitized and processed by wcc.
For support in the evaluation of soil dynamic properties and
cyclic strength,WCC has one of the finest soil laboratories
in the country in Oakland,California.The laboratory has
extensive experience in dynamic testing of soils.In
addition,the laboratory has conducted extensive testing of
frozen soils,mostly for the Alyeska pipeline project.
Field support services for evaluation of soil dynamic
properties include a strong geophysics capability,including
proven equipment and techniques developed by WCC for the in
situ measurements of shear wave velocity.
The types of earthquake engineering services summarized
above have been applied to a variety of construction pro-
Woodward-Clyde Consultants
jects,including dams,nuclear power plants,offshore oil
and gas platforms,port developments,bridges,LNG facili-
ties,pipelines,and many other industrial and commercial
projects.
llt"FLUOR POWER
.T'SERVICES,INC.
RESUMES
Following is a list of proposed personnel for the study on alternative
.power sources in the Railbelt area of Alaska.A detailed resume
for each is contained in this section:
John S.Coons
Shinn Inouye
Sidney Mayster
Achyut V.Setlur
John Truitt
Senior Mechanical Engineer
Manager,Structural Division
Manager,Generating Plant
Systems
Supervising Structural Engineer
Supervising Electrical Engineer
-
JOHN S.COONS
SENIOR MECHANICAL ENGINEER
DATE AND PLACE OF BIRTH:
,FLUOR
Resume
June 30,1947,Evanston,Illinois
EDUCATION:
B.S.in Mechanical Engineering
Clemson University,1968
M.S.in Mechanical Engineering
Northwestern University,1978
SUMMARY OF EXPERIENCE:
Lead engineer in Power Technology Division,responsible for technical
direction and daily administrative duties.In charge of fluid flow
analysis;turbine-generator cycle analysis and optimization,cooling
system cycle analysis and optimization;and relief valve and discharge
piping fluid analysis.Supervises the preparation of design studies and
evaluation reports for major power plant systems and components.
Responsible for application and results of computer programs dealing
with analysis of mechanical components.
Developing equations for a computer program which would enable a plant
operator to evaluate plant performance and to make comparisons with past
perf'ormance,correcting for weather conditions,makeup,etc.
Plant heat cycle analysis and evaluation,performance analysis and
optimization of major plant systems,and systems transient performance
analysis.
Responsible for integration of steam turbine-generator cycle analysis
with the cooling cycle analysis leading to lower plant cost.Responsible
for evaluation of industrial heat cycles (cogeneration)used to produce
electrical power and process steam.Includes consideration and evaluation
of various alternatives in terms of capital cost,operating cost,and
operational flexibility.
Responsible for the development,maintenance,and application of a
generalized analytical computer model for thermal analysis of fossil and
nuclear steam turbine-generator cycles.
FLUOR POWER SERVICES.INC.
-
RESUME:JOHN S.COONS
Involved in conceptual design of a computer program for evaluation of
cooling systems for Florida Power Corporation.Responsible for development
and computerization of analytical methods to calculate steam turbine-
generator cooling system performance and deaerator boiler feed pump
transients.
Conducted analytical research for the development of a gas turbine
waste heat recovery boiler computer program for both industrial and
aircraft type gas turbines as well as fired or unfired waste heat
recovery boilers.
Conducted engineering evaluation studies for the selection of steam
turbine-generators,analysis of safety relief valve systems,feedwater
heater control valves,and steam turbine cooling systems.Provided
expertise on modifications to proposed and existing steam turbine
cycles.
TECHNICAL SOCIETY:
American Society of Mechanical Engineers
REGISTRATION:
Professional Engineer:Illinois No.62-35628,1977
FLUOR POWER SERVICES,INC.,CHICAGO,ILLINOIS (1971 to Present)
PROJECT ENGINEER
Trimble County Unit 1
550 MW Coal-Fired
Madison Power Plant
ANALYTICAL ENGINEER
Dresden Power Station
Study of Plant Operation During
Repair
Mill Creek 4
495 MW Coal-Fired Plant
Mill Creek 3
495 MW Coal-Fired Plant
Growth Project for Computerization
of Steam Turbine Generators
Louisville Gas &Electric Co.
Trimble County,Kentucky
Oscar Mayer &Company
Madison,Wisconsin
Commonwealth Edison Co.
Morris,Illinois
Louisville Gas &Electric Co.
Louisville Gas &Electric Co.
Fluor Power Services,Inc.
Chicago,Illinois
Page 2 of 3
RESUME:JOHN S.COONS
PRATT &WHITNEY AIRCRAFT,EAST HARTFORD,CONNECTICUT (1969 to 1971)
ANALYTICAL ENGINEER
Member of a team which developed a modular computer program for the
simulation of gas turbine cycles.Responsible for producing a
computer program to interpolate data points of compressor and turbine
maps.Responsible for optimization of gas turbine engines,used in
a pUblication to·airframe manufacturers.
Page 3 of 3
1/79
SHINN INOUYE
MANAGER,STRUCTURAL DIVISION
DATE AND PLACE OF BIRTH:
Resume
-
December 8,1930,Centerville,California
EDUCATION:
B.S.in Architectural Engineering
University of Illinois,Urbana,Illinois,1953
~UMMARY OF EXPERIENCE:
In his more than twenty years with the company,Inouye has served in a
variety of capacities,beginning as a design engineer and culminating
with his assignment as manager of the structural division.In this
position,he administers all structural engineering and design,architectural,
civil/hydraulic and structural analytical work contracted by the company.
He approves manpower and cost estimates,assigns key personnel to projects,
and supervises all structural division activities.
As project structural engineer on the Kewaunee Nuclear Power Plant
project,he was responsible for structural,civil/hydraulic,and architectural
engineering and design,specifications and procurement of materials,
construction and quality assurance and control interface.The project
used innovative engineering and construction techniques such as the
multibarrier containment concept,building block design that resulted in
time and cost savings by the elimination of piles due to greatly reduced
differential settlements,and a leak tight spent fuel storage pool.
Previous assignments involved structural design work for a number of
facilities including fossil-fueled generating plants from 44 to 550 MW,
gas turbine units,and substations.
LANGUAGES:
Japanese
PROFESSIONAL SOCIETIES:
SPEAK
Moderate ly We 11
American Society of Civil Engineers
American Concrete Institute
American Society of Testing Materials
FLUOR POWER SERVICES,INC.
RESUME:SHINN INOUYE
REGISTRATIONS:
Structural Engineer:
Professional Engineer:
Illinois No.81-3121,1967
Wisconsin No.E10731 ,1968
FLUOR POWER SERVICES,INC.,CHICAGO,ILLINOIS (1956 to Present)
MANAGER,STRUCTURAL DIVISION
PROJECT MANAGER
Calloway Nuclear Power Plant
Units 1 &2
Cooling Water Pipe and Water
Management Plan Review
PROJECT STRUCTURAL ENGINEER
Kewaunee Nuclear Power Plant
Unit 1 (550 MW)&345 kV Substation
Weston Substation
345/115 kV
Waukegan Generating Station
Gas Turbine Installation
Terminal Substation
345/115 kV
Parkers Lake Substation
Sycamore Gas Turbine and
Associated Substation
Fitchburg,Nine Spring,and
Pheasant Branch Substations
ASSISTANT PROJECT ENGINEER
Allen S.King Generating Station
Unit 1,574 MW Coal-Fired and
345 kV Substation
Union Electric Co.
St.Louis,Missouri
Wisconsin Public Service Corp.
Green Bay,Wisconsin
Wisconsin Public Service Corp.
Green Bay,Wisconsin
Commonwealth Edison Co.
Waukegan,Illinois
Northern States Power Co.
Minneapolis,Minnesota
Northern States Power Co.
Minneapolis,Minnesota
Madison Gas &Electric Co.
Madison,Wisconsin
Madison Gas &Electric Co.
Madison,Wisconsin
Northern States Power Co.
Bayport,Minnesota
Page 2 of 3
RESUME:SHINN INOUYE
FLUOR POWER SERVICES.INC .•CHICAGO.ILLINOIS (CONT)
ASSISTANT STRUCTURAL ENGINEER
Pulliam Generating Station
Unit 8,125 MW Coal-Fired
Cane Run Generating Station
Unit 6,250 MW Coal-Fired
and Associated Substations
GROUP LEADER
Blount Street Generating Station
Unit 7,50 MW Fossil-Fired
and Associated Substations
South Bay Generating Station
Two 140 MW Units Oil-Fired
and Associated Substations
Highway IIV II Substation
DESIGN ENGINEER
Pulliam Generating Station
Unit 7,75 MW Coal-Fired
and Associated Substation
Wisconsin Public Service Corp.
Green Bay,Wisconsin
Louisville Gas &Electric Co.
Louisville,Kentucky
Madison Gas &Electric Co.
Madison,Wisconsin
San Diego Gas &Electric Co.
San Diego,California
Wisconsin Public Service Corp.
Green Bay,Wisconsin
Wisconsin Public Service Corp.
Green Bay,Wisconsin
CORN PRODUCTS REFINING COMPANY.CHICAGO,ILLINOIS (1955 -1956)
DESIGN ENGINEER
Analyzed existing and designed new structural systems for supporting
process equipment and tanks.
831
Page 3 of 3
11/78
ROBERT W.LARSON
SUPERVISOR -PRELIMINARY PLANNING SECTION
DATE AND PLACE OF BIRTH:
September 8,1922,Galesburg,Illinois
EDUCATION:
Courses in Physics and Mathematics
Central YMCA College
SUMMARY OF EXPERIENCE:
Resume
Serves as the Supervisor,Preliminary Planning Section,with responsi-
bility for preliminary design and layout necessary to initiate power
plant projects.
As Planning Section Group Leader,performed the design and layout of
several fossil-fired power plants ranging in size from 50 MW to 500 MW,
and a 530 MW nuclear power plant.Duties included preparation of site
layout;general arrangement,piping and ventilation system drawings;
coordination and review of mechanical and electrical equipment and
piping,plumbing,and ventilation systems;and liaison with equipment
manufacturers in regard to turbine,steam generator,pump,heat
exchangers,tanks,and other heavy equipment drawings.
Industrial experience also includes layout of two boiler installations
and a precipitator retrofit.
FLUOR POWER SERVICES,INC.
RESUME:ROBERT W.LARSON
FLUOR POWER SERVICES,INC.,CHICAGO,ILLINOIS·
(1952 to Present)
PRELIMINARY PLANNING SUPERVISOR
S02 System and Baghouse
Installation Study
Trimble County Power Plant
Site Layout
Mill Creek Power Plant Site
Site Layout
Standard Cycling Plant Site
Layout
Power Plant Layout for
Chemical Complex
Power Plant Layout for
SASOL Project
Steam Plant Layout for
Chemical Complex
Precipitator Installation
Argonne National Laboratory
Argonne,Illinois
Louisville Gas &Electric Co.
Louisville,Kentucky
Louisville Gas &Electric Co.
Louisville,Kentucky
Commonwealth Edison Company
Chicago,Illinois
Oriente Petrochemical Complex
Venezuela
South African Coal,Oil,and
Gas Corporation
Chemplex Corporation
Clinton,Iowa
Abbott Laboratories
North Chicago,Illinois
MECHANICAL DESIGN &DRAFTING GROUP LEADER
Enrico Fermi Nuclear Power
Plant,Unit 2
Sun Desert Nuclear Power
Plant Layout Study
Kewaunee Nuclear Power Plant
Boiler Installation at
Chemical Plant
PIPING DESIGNER AND CHECKER
Encina Power Plant
Units I,2,&3
South Bay Power Plant
Units I,2,&3
Detroit Edison Company
Detroit,Michigan
San Diego Gas &Electric Co.
San Diego,California
Wisconsin Public Service Corp.
Madison,Wisconsin
General Mills Chemicals
Kankakee,Illinois
San Diego Gas &Electric Co.
San Diego,California
San Diego,Gas &Electric Co.
San Diego,California
RESUME:ROBERT W.LARSON (Cont)
FLUOR POWER SERVICES,INC.,CHICAGO,ILLINOIS (Cont)
(1952 to Present)
Blount Street Station
Allen S.King Generating Plant
Mill Creek Generating Station
Units 3 &4
F.H.MCGRAW COMPANY,(1951 -1952)
PIPING DESIGNER
Power Plant for Chemical
Complex
Madison Gas &Electric &Co.
Madison,Wisconsin
Northern States Power Company
Minneapolis,Minnesota
Louisville Gas &Electric Co.
Louisville,Kentucky
Linde Air Products Company
East Chicago,Indiana
PIONEER SERVICE &ENGINEERING COMPANY,CHICAGO,ILLINOIS (1950 -1951)
PIPING DRAFTSMAN
Minot,Fargo,Grand Forks,
and Black Dog Power Plants
Northern States Power Company
Minneapolis,Minnesota
K11:19,20,21, 22,23
j FLUOR
SIDNEY MAYSTER Resume
MANAGER,GENERATING PLANT SYSTEMS
DATE AND PLACE OF BIRTH:
February 13,1922,Chicago,Illinois
EDUCATION:
Advanced Courses in Reactor Design
Northwestern University,School of Engineering,Chicago,Illinois
Graduate Studies in Mechanical Engineering
Illinois Institute of Technology,Chicago,Illinois
B.S.in Mechanical Engineering
Illinois Institute of Technology,Chicago,Illinois,1945
SUMMARY OF EXPERIENCE:
Manages group of specialists doing initial planning,system definition,
and study work on power plant projects.Previously,responsible for the
overall supervision of engineering disciplines within the company.
As a generalist in environmental engineering,develops a systematic
approach to problem solving,concentrating on a synthesis of disciplines
both scientific and managerial with in-depth knowledge of environmental
methods of systems analysis and impact assessment.
Served as project director and project manager for a Middle East client,
as well as for domestic utilities.Responsible for the management of
engineering and design of fossil-fuel unit projects,ranging in capacity
from 100 MW to 750 MW.Developed testing procedures and supervised test
team on performance tests and evaluation of results.
Responsible for the developmental study of new technology on the effects
of helium on circulating equipment associated with the HTGR.Involved
in the development of steam tables for heavy water and heavy water
technology in application to reactors.
In charge of organizing Middle East office,which included acting as
liaison between client and home office.Supervised startup of units.
Began mechanical analytical department,including the training of personnel,
and developing computer programs and standardized analytical techniques.
FLUOR POWER SERVICES.INC.
RESUME:SIDNEY MAYSTER
TECHNICAL SOCIETIES:
American Nuclear Society
Illinois Society of Engineers
Western Society of Engineers
REGISTRATIONS:
Professional Engineer:Illinois No.62-17601,
Ohio No.37736,
KentucKy No.9253,
California No.0695.
FLUOR POWER SERVICES,INC.,CHICAGO,ILLINOIS (1974 to Present)
MANAGER,GENERATING PLANT SYSTEMS
Manages assigned engineers and specialists doing system definition
design study work on power plant projects.
DIRECTOR OF ENGINEERING
Responsible for the overall supervision of engineering disciplines
within the company.
SARGENT &LUNDY ENGINEERS,CHICAGO.ILLINOIS (1947 to 1974)
PROJECT DIRECTOR
Was an associate at Sargent &Lundy from 1966 to time of leaving.
Set up engineering liaison office in the Middle East.Responsible
for the complete organization and coordination of the office.
Additionally responsible for handling the account of the American
Electric Power Company,one of the largest utilities in the country.
Managed,engineered,and,as included in the scope of work,supervised
startup and performance testing on the following power plant
installations:
Wabash River Generating Station
4 Units,100 MW (Each)Coal-Fired
Gallagher Generating Station
2 Units,150 MW (Each)Coal-Fired
Haifa Station
2 Units,200 MW (Each)Fossil-Fired
Page 2 of 3
Public Service Co.of Indiana
West Terra Haute,Indiana
Public Service Co.of Indiana
New Albany,Indiana
Israel Electric Corp.
Haifa,Israel
RESUME:SIDNEY MAYSTER
SARGENT &LUNDY ENGINEERS,CHICAGO,ILLINOIS (CONT)
Reading Generating Station
4 Units,325 MW (Each)Fossil-Fired
325,000 KW each
Ashdod Generating Station
4 Units,400 MW (Each)Fossil-Fired
Cardinal Power Plant
700 MW Unit,Coal-Fired
MECHANICAL ENGINEER
Israel Electric Corp.
Israel Electric Corp.
American Electric Power Co.
(Ohio Power Co.)
Brilliant,Ohio
Organized and managed the mechanical analysis section,which was
the first department utilizing computer programs for analytical
work.Trained personnel,developed standardized analysis techniques.
Also responsible for field tests and startup assistance.
K11:3,6,9,16,24,25,
26,27
Page 3 of 3
1/79
-
,FLUOR
ACHVUT V.SETLUR Resume
SUPERVISING STRUCTURAL ENGINEER
DATE AND PLACE OF BIRTH:
July 4,1937,Bombay,India
EDUCATION:
.B.E.in Civil Engineering
Bombay University,Bombay,India,1959
M.S.C.E.in Structural Engineering
Purdue University,1962
Ph.D.in Structural Engineering
Purdue University, Lafayette,Indiana,1965
Intensive Course on Recent Advances in
Earthquake Resistant Design of Structures
Berkeley,California,1976
SUMMARY OF EXPERIE~CE:
Manages structural research and development and project structural
analysis activities within the Structural Division.
Project structural engineer on Prairie Island and Kewaunee follow-on
projects.Project structural analysis engineer on the FPS Standard
Nuclear Power Plant (BOPSSAR).
Senior structural engineer on special structures and problems associated
with fossil power plants such as hyperbolic cooling towers,chimneys,
mat,foundations,and dynamic and seismic analysis problems.
Supervising engineer on the development and use of computer codes for
dynamic,seismic,and stress analysis using finite elements for nuclear
power plant structures,including impactive and impulsive load analysis
and nonlinear behavior.
Associate professor of structural engineering.Guided several Masters
and Ph.D.students in their research.Consultant on several high rise
and industrial structures.
Author of more than 20 papers in leading national and international
technical journals.
FLUOR POWER SERVICES.INC.
RESUME:ACHYUT V.SETLUR
TECHNICAL SOCIETIES:
American Society of Civil Engineers
Seismic Analysis Committee,ASCE Nuclear Structures and
Materials Committee
Task Group on Compressive A110wab1es,ASME Boiler and Pressure
Vessel Code Committee
REGISTRATION:
Structural Engineer:Illinois No.81-3962,1975
FLUOR POWER SERVICES,INC.,CHICAGO.ILLINOIS (1971 -Present)
SUPERVISING STRUCTURAL ENGINEER
Trimble County Generating Station,
Unit 1,495 MWe Coal-Fired
Cooling Tower B10wdown Discharge
Studies
Encina Generating Station
Units 1-5,Oil-Fired
Intake and Discharge System
Model Studies
PROJECT STRUCTURAL ENGINEER
Prairie Island Nuclear Generating
Station
Two 550 MWe Units
Kewaunee Nuclear Generating Station
One 550 MWe Unit
PROJECT STRUCTURAL ANALYSIS ENGINEER
Standard Nuclear Reference Plant
1300 MWe Unit
Westinghouse PWR
SENIOR STRUCTURAL ENGINEER
Trimble County Generating Station
Unit 1,495 MWe Coal-Fired
Encina Generating Station
Unit 5,327 MWe Oil-Fired
Page 2 of 4
Louisville Gas &Electric Co.
Louisville,Kentucky
San Diego Gas &Electric Co.
San Diego,California
Northern States Power Co.
Red Wing.Minnesota
Wisconsin Public Service Corp.
Green Bay.Wisconsin
Fluor Power Services,Inc.
Chicago,Illinois
Louisville Gas &Electric Co.
Louisville,Kentucky
San Diego Gas &Electric Co.
Carlsbad,California
RESUME:ACHYUT V.SETLUR
FLUOR POWER SERVICES,INC.,CHICAGO,ILLINOIS (CONT)
Prairie Island Nuclear
Generating Station
Two 550 MWe Units
Mill Creek Generating Station
Units 3 &4,417 &530 MWe Coal-Fired
STRUCTURAL ENGINEER
Encina Generating Station
Units 4 &5,327 MWe (Each)Oil-Fired
Conceptual Design Study
Proposed Nuclear Power Plant
Standard Nuclear Reference Plant
Babcock &Wilcox PWR
Northern States Power Co.
Red Wing,Minnesota
Louisville Gas &Electric Co.
Louisville,Kentucky
San Diego Gas &Electric Co.
San Diego,California
San Diego Gas &Electric Co.
San Diego,California
Fluor Power Services,Inc.
Chicago,Illinois
Structural computer codes development.Use of NASTRAN,STARDYNE,
SAP,ANSYS,STRUDL,and DYNAL for power plant structures.
INDIAN INSTITUTE OF TECHNOLOGY,KANPUR,INDIA (1966 -1971)
ASSOCIATE PROFESSOR
Taught undergraduate courses in mechanics of solids and senior
project work;graduate courses in structural analysis,numerical
analysis in engineering,structural stability and dynamics.
Guided Masters and Ph.D.students in their theses.
CONSULTANT
Static,dynamic,and stress
analysis of high rise struc-
tures and industrial plants.
Page 3 of 4
Engineering Consultant
(India)Ltd.
Chemical &Metallurgical
Design Co.,Ltd,India
The K.C.P.Ltd,India
Triveni Structura1s,India
RESUME:ACHYUT V.SETLUR
PURDUE UNIVERSITY,LAFAYETTE,INDIANA (1965 -1966)
VISITING ASSISTANT PROFESSOR
Taught undergraduate courses in structural analysis,graduate
cours.s in structural mechanics.Research in shell structures
and computer code development.
CONSULTANT
Wind stress analysis of 100 story
John Hancock Center.
GAMMON INDIA,LIMITED (1959 -1961)
Page 4 of 4
Skidmore,Owings &Merrill
Chicago,Illinois
Published Technical Papers
Dr.A.V.Set1ur
1."Computer Analysis of Folded Plate Structures II with J.E.Goldberg and
W.D.G1auz,Proceedings of the Seventh Congress of Intn1.Assoc.of
Bridge and Struct.Engg.,August 1964.
2."Ana1ysis of Noncircular Cylindrical Shells"with J.E.Goldberg and
D.W.Alspaugh,Symposium of Intnl.Assoc.of Shell Structures (lASS),
Budapest,Hungary,1964.
3."Computer Analysis of Rotating Nonuniform Discs"with J.E.Goldberg,
Ninth Midwestern Mechanics Conference,Wisconsin,August 1965.
4."Stability of Large-Span Domes with Prestressed Edge Rings"with
J.E.Goldberg,Symposium of I.A.S.S,Leningrad,USSR,1966.
5."Stability of Long-Span Folded Plate Structures II with J.E.Goldberg,.
Symposium of I.A.S.S,Leningrad,USSR,1966.
6."Nonlinear Axisymmetric Buck.ling of Shallow Spherical Shells"with
S.K.Radhamohan,Tenth Indian Congress on Theoretical and Applied
Mechanics,December,1968.
C.Das and
Earthquak.e
7.liThe Koyna-India Earthquak.e"with G.V.Berg,Y.
K.V.G.K.Gok.hale,Fourth World Conference on
Engineering,Chile,January 1969.
8."Torsion of Prismatic Concrete Members by the Finite Element Method"
with A.H.Shah and A.Chatterjee,International Conference on
Torsion,Shear and Bond in Reinforced and Prestressed Concrete,
January 1969.
9."Method of Initial Functions in Two-Dimensional E1asto-Dynamic
Prob1ems"with Y.C.Das,Journal of Applied Mechanics,Transactions
of ASME,March 1970.
10."Transient Response of Dam-L i k.e Structures to Earthquake"with
S.Basu,Journal of the Indian Earthquak.e Society,March 1970.
11."A Mixed Finite Element Formulation for Plate Problems"with
A.Chatterjee International Journal of Numerical Methods in
Engineering,1971.
12."Nonl i near Stabil ity Analysi s of General Shell s of Revol ution"with
S.K.Radhamohan and J.E.Gal dberg,Journal of the Structural
Division,ASCE,June 1971.
13."Parametric Differentiation Method to Structural Optimization
Problems"with M.P.Kapoov,Journal of the American Institute of
Aeronautics and Astronautics,November 1970.
14."Structural Optimization Using Parametric Differentiation"with
P.C.Pande and M.P.Kapoor,Twenty-third Annual General Meeting of
the Aeronautical Society of India,February 1971.
15."Finite Element Method in Continuum Mechanics Problems"with
A.Chatterjee,Third Matrix Methods Conference,Wright Patterson Air
Force Base,Dayton,Ohio,October 1971.
16."A New Approach to Soil-Structure Interaction Problems"with
J.K.Khanna and M.Valathur,ASCE Specialty Conference on Structural
Design of Nuclear Power Plant Facilities,Chicago,Ill.,December
1973.
17."Asymmetric Buckling of Thin Shells of Revolution by Parametric
Differentiation Technique"with S.K.Radhamohan,Journal of Applied
Mechanics,Trans.of ASME,December 1974.
18."Some Studies on the Use of NASTRAN for Nuclear Power Plant Structural
Analysis and Design"with M.Valathur,Third Colloquium on NASTRAN
User's Experience,Hampton,Virginia,September 1972.
19."Earthquake Response of a 300 M.High T.V.Antenna Tower"with
M.P.Kapoor and Y.C.Das,Sympos i um on Earthquake Engi neeri ng,
Roorkee,India,November 1970.
20."Seismic Design Considerations for a Standard Nuclear Power Plant,"
presented and published in the 37th Annual Meeting of the American
Power Conference,Chicago,Ill.,April 1975.
21."S e ismic Soil-Structure Interaction by Finite Elements Case Studies"
with V.Pandya,ASCE Speciality Conference,New Orleans La.,Dec.
8-10,1975.
22."Bearing Pressure Under Foundation Mats due to Triaxial Seismic
Excitation,"with S.R.Parimi,ASCE Special ity Conference,New
Orleans,La.,Dec.8-10,1975.
23."Nonl inear Sei smic Soil-Structure Interacti on Analysi s of Nucl ear
Plant Structures,"with D.V.Pathak and J.K.Khanna,4th SMIRT
conference,San Francisco,Ca.,Aug.1977.
24."Operati ng Experiences on Breechings,Expansion Joi nts and Stack
Liners for Fossil Stations,"with V.P.Goel,presented and published
in the 41st Annual Meeting of the American Power Conference,Chicago,
Illinois,April 1979.
JOHN TRUITI
SUPERVISING ELECTRICAL ENGINEER
DATE AND PLACE OF BIRTH:
Resume
January 11,1935,Fort Washington,Pennsylvania
EDUCATION:
B.S.in Electrical Engineering
University of Cincinnati,Cincinnati,Ohio,1957
M.S.in Electrical Engineering
University of Cincinnati,1966
Advanced Courses in Electrical Engineering
University of Cincinnati
University of Wisconsin
SUMMARY OF EXPERIENCE:
Project electrical engineer responsib1ity on major power generation,
combustion tu'rbine,substation and other related projects.Duties
include lead engineering and design responsibility,feasibility studies
and estimates,evaluation and preparation of equipment specifications,
and bid analysis and purchasing recommendations.
Electrical engineering experience includes computer programming,utility
generation and transmission planning studies,protective relaying work,
and power equipment application to the utility,petrochemical,steel,
and paper industries.
Has taught at the university level and holds a first class radio telephone
operator's license.
TECHNICAL SOCIETY:
Senior Member -Institute of Electrical and Electronic Engineers
REGISTRATIONS:
Professional Engineer:Ohio No.28075
Kentucky No.6089
Illinois No.62-28254
California No.7388
FLUOR POWER SERVICES,INC.
RESllME:JOHN TRUITI
FLUOR POWER SERVICES,INC.,CHICAGO,ILLINOIS (1969 to Present)
PROJECT ELECTRICAL ENGINEER
-
Wastewater Project
Endna Unit 5
300 MW Fossil
End na Unit 4
300 MW Fossil
Substation Projects
Various Sizes thru 138 kV
Gas Turbine Units
Various Sizes thru 60 MW
Fuel Oil Storage Facilities
Various Sizes thru 160 krn 3
Engineering Studies
ELECTRICAL ENGINEER
South Bay Unit 4
240 MW Fossil
Substation Projects
Various Sizes thru 138 kV
Gas Turbine Projects
Various Sizes thru 30 MW
Fuel Oil Storage Facilities
Various Sizes through 89 krn 3
San Diego Gas &Electric Co.
San Diego,California
San Diego Gas &Electric Co.
San Diego,California
San Diego Gas &Electric Co.
San Diego,California
San Diego Gas &Electric Co.
San Diego,California
San Diego Gas &Electric Co.
San Diego,California
San Diego Gas &Electric Co.
San Diego,California
San Diego Gas &Electric Co.
San Diego,California
San Diego Gas &Electric Co.
San Diego,California
San Diego Gas &Electric Co.
San Diego,California
San Diego Gas &Electric Co.
San Diego,California
CINCINNATI GAS &ELECTRIC COMPANY (1962 -1969)
ASSOCIATE ELECTRICAL ENGINEER
Scientific computer programming,generation reserve level studies,
transmission planning studies,transmission loss studies,and
protective relaying work.
Page 2 of 3
,...
-
RESlIME:JOHN TRUITT
UNIVERSITY OF CINCINNATI (1964 -1969)
LECTURER ON ELECTRICAL ENGINEERING
Taught basic circuit analysis and professional engineering license
review courses.
ELLIOTT·COMPANY,DIVISION OF CARRIER CORP.(1957 -1962)
APPLICATION ENGINEER
Field sales and application of power apparatus to the utility,
petrochemical,steel,and paper industries.