HomeMy WebLinkAboutProgress report 1956 field investigations devil canyon damsite 1957UNITED STATES DEPARTMENT OF TEE INTERIOR
FISH and WU.m·IFE SERVICE
JUNEAU, ALASKA
PROGRESS REPORT
1956 FIELD INVESTIGATIONS
!EVIL CANYON DAMSITE, SUSITNA RIVER BASIN
TERRITORY of ALASKA
July, 1957
For Administrative Use Only
I
....
-.
-'I
UNITED STATES DEPARTMENT OF THE INTERIOR
FISH a nd WILDLIFE SERVICE
JUNEAU ,ALASKA
ervice
PROGRES S REPORT
1956 FIELD INVESTIGATIONS
DEVIL CANYON DAMSITE .SUSITNA RIVER BASI N I
TERRITORY of ALASKA
July,195 7
For Administrative Use Only
ARLI S
:\1 8 RelOUrces UbralY &InfonnadOQ SoMQOS
UbnuY BuildIng.Suito 111
3211 Providence DriveAnchora~.AK 99508-46 14
F\VLr.;
11 77
SUSITNA RIVER BASIN
ALASKA
SUSITNA REPORT
1.For many years,the Susitna Basin has been an area of extreme
interest to the people of the Territory as a potential source of hydro-
electric power for South Central Alaska.The basin lies north of the
farthest inland projection of Cook Inlet between latitudes 610
-640 and
longitudes 1460 -153 0 •Its total drainage area comprises 19,300 square
miles of virtually uninhabited lands.This area is bordered on the south
by the waters.·of Cook Inlet;on the east by the Chugach and Talkeetna
Mountains;and on the west and north by the Alaska Range.
2.The main stem of the Susitna River,from its source in the
Alaska Range to its point of discharge into Cook Inlet,is approximately
275 miles long.The principal tributaries have their origin in glaciers
high in the mountains and)for the mOpt part,are turbulent in the upper
reaches and slow-flowing in the lower regions.Most of the tributaries
carry a heavy load of glacial silt.
3.In August of 1952,the Bureau of Reclamation published a
report entitled '!Report on the Potential Development of Water Resources
in the Susitna River.Basin of.Alaskall •Their plan·of development in-
c1ud~19 potential.damsites,widely distributed throughout the Basin.
However,only 12 of the original 19 sites are presently being considered
for development.The one currently considered most feasible and most
likely to be developed first is the site at Devil Canyon,Figure 1.
Figure 1.View of proposed Devil Canyon Damsite,
showing rapids and river gorge.*
4.The proposed Devil Canyon Dam would consist of a concrete
arch-gr~vity structure having a crest height of approximately 500 feet
above the existing stream bed.A side channel spillway equipped with
36-x 50-foot radial gates and an initial power plant capacity of
232,000 IwJH are also planned.
5.Approximate stream gradient at the proposed damsite is 19
feet per mile and the drainage area above the damsite includes 5,830
square miles.Dimensions of the proposed reservoir are presented in
Table 1.
*Photo by Bureau of Reclamation.
2
Table 1.Dimensions of the proposed Devil Canyon Reservoir
~.Min.
Capacity (100 AC.-F*2,510 616
Ar~a (Acres)15,200 6,400
Depth at Dam (Ft)492 291
Length (Miles)26 14
Ave.-age Width (Ft)4,800 3,800
2,020
455
24
4,600
*These amounts include reduction in capacity to allow for estimated
sediment deposition over a 100-year period,assuming no upstream reser-
vQirs on the main stem..
NOTE:The above data are based on initial development of only Devil
C2+Qyon -.Res~rvoir,and .Power .Pl.ant ,
·6.,The Sus.itna·River·is eonsidered one of the most important
salmon spawning streams in the Cook Inlet region and annually contributes
a major.portion of the Cook Inlet salmon pack.This contribution is
valued inexpess of $1,900,000 annually.
7.Investigations of-a preliminary nature were conducted by the
Fishiand Wildlife Service in the Basin in 1952 and 1953 and the following
reports were prepared:
L·A Preliminary Statement···of'Fish and Wildlife Resources of·
the Susitna,Basin in Relation to Water Development Projects p
1952 .•
20 A Progress Report on the Wildlife Resources of the
Susitna Basin,1954•.
3.A,Progress Report on the Fishery Resources of the Susitna
River.Basiu.1954.
8.In the summer of 1956,the Bureau of Reclamation resumed de~
taileg feasibility studies of thisdamsite.In order to keep pace with
their ipvestigations,the Fish and Wildlife Service began detailed
3
studies of project effects the same year.Although earlier reconnais-
sance indicated that anadromous species did not utilize the watershed
above the Devil Canyon Damsite,detailed studies were required to verify
our previous conclusions.The primary objectives of this study are as
follows:
1.To determine the extent anadromous species utilize the
Susitna River above the proposed Devil Canyon Damsite for
spawning and rearing purposes.
2.To determine the extent anadromous species utilize the
watershed between the damsite and the town of Curry.
3.To obtain general information relative to magnitude and
distribution of resident fish populations that would be
affected by project development.
4.To determine whether access blocks to anadromous species
exist on the main stem of the Susitna River above the proposed
site.
9.The area covered by these investigations was that section of
the Susitna River between Curry and the confluence of Jay Creek,Figure 6.
In this section,the river is confined to a narrow,steep-walled canyon.
Mountains rise abruptly to elevations exceeding 2,000 feet above the
stream bed.The stream gradient is relatively steep,with the steepest
grade occurring between the confluence of Devil Creek and Portage Creek.
It is in this area where hydraulic barriers to migratory fish may occur,
as shown in Figures 2,3 and 4.
4
Figure 2.,-Jest end of Devil Canyon,showing steepness of canyon walls.
Figure 3.Susitna River approximately 3 miles upstream from the Vevil
Canyon Damsite.
5
Figure 4.Possible hydraulic barrier to ascending salmon several miles
above Devil Canyon Damsite.Note slide lower right.
10.Two methods were used to determine the value of the fishery
resources of this section of the river.Gillnetting during the period of
salmon migration provided direct evidence of their presence below the
damsite,Figure 5.Resulting catch rates gave some indication of their
abundance.Tributary streams were surveyed from the air and ground to
provide counts of spawning salmon and to estimate the extent of suitable
spawning gravels.Observations were also made to determine the presence
of natural obstructions to migrating salmon,both in the tributary streams
and in the main stream of the Susitna.
11.In addition to the use of gillnets,sampling was also done by
means of a minnow seine and hook and line fishing.Representative
samples of all species were weighed,measured,and sexed,and scale
samples were taken for age and growth analysis.
6
Figure 5.View of gillnet set in eddy in Devil Canyon below damsite.
GILLNETTING RESULTS
12.On June 16,king salmon nets were set in the locations indi-
cated on the map,Figure 6.Sets were made both above and below Portage
Creek.The first king salmon was netted on July 7,and the last on
July 17.The peak of the run,as indicated by daily gillnet catches,was
approximately July 12.Red salmon nets were set on the 19th and 20th of
August and fished until the 9th of September.The locations of these
sets are also presented in the map, and the catches of both species below
the damsite are recorded in Table 2.
7
Table 2.The amount of gillnet fished;the number of hours fished;
and the catch of each species above and below Portage Creek.
Fathoms Total :Area between Damsite Area
of Hours :and Portage Creek Below Portage Creek
Gillnet Fished:King Red Silver Chum Pink King Red Silver Chum Pink
13 1749 4 0 0 0 0
16 2207 18 0 0 0 0
10.8 574 0 4 2 23 0
3.3 544 0 3 53 61 1
4 4 2 23 0 18 3 53 61 1
13.Catch rates were determined for gillnets set above and below
Portage Creek.The following formula was used in these computations:
catch rate =total hours fished x fathoms of gillnet.
catch
To indicate relative abundance,the resulting catch rate for each
species above Portage Creek was divided by its respective catch rate
below Portage Creek,thus yielding a percentage figure.These computa-
tions follow:
King Salmon
Below:
Above:
2207 x 16 =1962 gear hours per fish captured.
18
1749 x 11 =5684 gear ho~rs per fish captured.
4
5684
1962
=290%faster rate of catch per unit
gear hours below Portage Creek
than above.
8
Churn Salmon
Below:
Above:
~44 x 1.1 =29.4 gear hours per fish captured.
61
~74 x 10.8 =269.5 gear hours per fish captured.
23
Red Salmon
=920%faster rate of catch per unit gear
hours below Portage Creek than
above.
Below:
Above:
~44 x 1.1 =598.4 gear hours per fish captured.
3
~74 x 10.8 =1,549.8 gear hours per fish captured.
4
Silver Salmon
1~49.8
598.4
=259%faster rate of catch per unit of
gear hours below Portage Creek
than above.
Below:
Above:
~44 x 1.1 =33.9 gear hours per fish captured.
53
~74 x 10.8 =3099.6 gear hours per fish captured.
2
3099.6
33·9
=914%faster rate of catch per unit of
gear hours below Portage Creek
than above.
9
STREAN SURVEYS
14.The tributary streams surveyed during the 1956 season are
discussed in order,beginning with Gold Creek and proceeding upstream.
All these tributaries,with the exception of Jay Creek,are located
downstream from Devil Canyon.Jay Creek is located approximately 55
miles upstream from Devil Canyon.All tributary streams from Indian
River upstream to Jay Creek,inclusive,were surveyed from the air and
no salmon were observed.
15.Gold Creek
This stream was not surveyed,but information regarding it was
obtained in an interview with ~1ichale Boddner,a homesteader in the area.
He stated that a few king salmon spawn in this creek and that 32 chum
salmon were spawning at the mouth on September 1.According to Boddner,
grayling,rainbow trout,and Dolly Varden trout are also found in Gold
Creek.
16.Indian River
This is a clear,fast stream approximately 25 feet wide and of
about 3t feet average depth.Aquatic vegetation includes algae and
mosses,while shoreline vegetation is composed chiefly of willow,poplar
and alder.The first mile upstream from the mouth possesses a gradient
considered too steep for salmon spawning.However,suitable spawning
areas were observed in the section from It to 5 miles upstream from the
mouth.Four surveys "f this section were made:Two were prior to
salmon migration,the third.was near the peak of the king salmon run,
when 22 of this species were observed,and the last was near the end of
August,when all runs--with the exception of the silver salmon migration--
10
were nearly complete.During this final survey,94 chum,9 pink and 6
silver salmon were observed alive;while 1 king,67 pink,and 193 chum
salmon were found dead.Aside from its value to spawning salmon,Indian
River also provides habitat for grayling and rainbow trout.
17.Jack Long Creek
This tributary possesses a steep gradient and contains clear,
slightly yellow-tinged water.Its bed is largely boulders and cobbles
and its banks are quite steep.Shoreline vegetation consists chiefly of
willow,cottonwood,and a variety of annuals.No salmon were seen nor
were their spawning beds observed.Four spawned-out pink salmon,however,
were found at the mouth of Jack Long Creek.This stream also supports
small grayling and rainbow trout populations.
18.Portage Creek
This creek is 40 to 60 feet wide and 5 to 8 feet deep.Its
waters are clear,blue-tinged,and the stream bed contains bottom materials
of all sizes,including gravels suitable for spawning salmon.Deep pools
are present throughout most of the length of Portage Creek.Some of these
are of such depth that spawning salmon could easily have been missed by
both aerial and ground observers.Shoreline vegetation is composed chiefly
of birch,willow,cottonwood and annuals.Aquatic vegetation is largely
moss and algae.Slide areas were noted on the right bank going upstream.
19.The first survey of Portage Creek was made at the beginning of
the king salmon run,and 3 of this species were observed.During the last
survey,which was made on September 9,1 live chum, 1 pink and 3 silver
salmon were observed moving upstream.A total of 10 chum and 11 pink
11
salmon were observed on the spawning gravels.A minimum of 30 red salmon
were seen spawning at the mouth of Portage Creek.
20.A king salmon gillnet was set diagonally across the mouth of
Portage Creek and was fished for eight days during the peak of the run.
Only four king salmon were taken and these were netted during the first
24 hours of the set.An observation post overlooking a clear section of
Portage Creek was manned for 46 hours during the run,and no king salmon
were observed.An aerial reconnaissance survey covering the total length
of the stream was made and no salmon were visible from the air.However,
as noted previously,spawning salmon may have been present in the deep
pools where they could not be discerned.Observations indicated that
grayling were abundant in Portage Creek while rainbow trout were rela-
tively scarce.
21.Devil Canyon
While the flow through this section of the Susitna is very
rapid and turbulent,it was found that side eddies exist along the canyon
wall which permitted the passage of a boat upstream well into the gorge.
It appeared that this area should provide no obstruction to migrating
salmon.If hydraulic obstructions do exist,they are probably located at
the proposed damsite and in the canyon area 8 miles above the site,
Figures 2,3 and 4.
22.Jay Creek
The gradient of this stream is quite gradual to a point approxi-
mately two miles upstream from its mouth,where there is a decided
increase in gradient.Its waters are yellow and turbid and about 2 to 3
feet deep.Its sandy,rocky shoreline is bordered by stands of white
12
spruce,cottonwood,willow,and alder.Neither salmon nor their spawning
beds were observed in the seven-mile section of Jay Creek which was sur-
veyed.Three gillnets were fished for a period of 494 hours in locations
adjacent to the mouth of Jay Creek,and no salmon were taken,indicating
the possibility that they were unable to migrate this far upstream in the
Susitna.
Sill'lMARY
25.Field investigations conducted in the Susitna River and its
tributaries during the 1956 season provided the following information:
1.Appreciable numbers of all five species of salmon were
captured by gillnet in the Susitna below the confluence of
Portage Creek.
2.In a stream section extending from Portage Creek almost to
the Devil Canyon Damsite,no pink salmon were taken,and only
small numbers of king,red,and silver salmon were netted.
However,an appreciable number of chum salmon were caught in
this section.
3.At Jay Creek,55 miles upstream from Devil Canyon,three
gillnets set for 494 hours captured no salmon.
4.Aerial surveys of all tributary streams from Indian River
to Jay Creek,inclusive,failed to reveal the presence of
salmon.
13
•
•
•
DISCUSSION
26,Field investigations during 1956 were intended to determine
whether salmon migrate up the Susitna Ri ver beyond the Devil Canyon
Damsite.All five species of salmon were captured in gillnets whi ch were
set downstream from the damsite.Those gillnet sets located nearest the
proposed site,however,took very few fish of only four species,the pink
salmon not being represented.Gillnets fished near the mouth of Jay
Creek,55 miles upstream from Devil Canyon,failed to take salmon although
they were set for 494 hours during the estimated peak of the mi gration.
Furthermore,extensive aerial surveys of the tributary streams failed to
reveal the presence of salmon upstream from Devil Canyon.However,it is
not believed that present data warrant the conclusion that an obstruction
definitely exists.Further field investigations will be conducted in
suitable spawning streams above Devil Canyon during the summer of 1957 .
14
FIGURE 6.THE SECTION OF THE SUSITNA RIVER IN WHICH FIELD INVESTIGATIONS WERE
CONDUCTED DURING 1956.