HomeMy WebLinkAboutSuWa35Alaska Resources Library & Information Services
Susitna-Watana Hydroelectric Project Document
ARLIS Uniform Cover Page
Title:
Wetland mapping study in the upper and middle Susitna basin
SuWa 35
Author(s) – Personal:
Author(s) – Corporate:
Prepared by ABR, Inc.--Environmental Research & Services
AEA-identified category, if specified:
2012 Environmental Studies
AEA-identified series, if specified:
Series (ARLIS-assigned report number):
Susitna-Watana Hydroelectric Project document number 35
Existing numbers on document:
Published by:
[Anchorage, Alaska : Alaska Energy Authority, 2013]
Date published:
February 2013
Published for:
Prepared for Alaska Energy Authority
Date or date range of report:
Volume and/or Part numbers:
Final or Draft status, as indicated:
Final report
Document type:
Pagination:
iv, 22 p.
Related work(s):
Pages added/changed by ARLIS:
Notes:
All reports in the Susitna-Watana Hydroelectric Project Document series include an ARLIS-
produced cover page and an ARLIS-assigned number for uniformity and citability. All reports
are posted online at http://www.arlis.org/resources/susitna-watana/
Alaska Resources Library & Information Services
Susitna-Watana Hydroelectric Project Document
ARLIS Uniform Cover Page
Title:
Wetland mapping study in the upper and middle Susitna basin
SuWa 35
Author(s) – Personal:
Author(s) – Corporate:
Prepared by ABR, Inc. - Environmental Research & Services.
AEA Identified Category, if specified:
2012 Environmental Studies
AEA Identified Series, if specified:
Series (ARLIS-assigned report number):
Susitna-Watana Hydroelectric Project Document number 35
Existing numbers on document:
Published by:
[Anchorage, Alaska : Alaska Energy Authority, 2013]
Date Published:
February 2013
Published for:
Prepared for Alaska Energy Authority
Date or date range of report:
Volume and/or Part numbers:
Final or Draft Status, as indicated:
Final
Document Type:
Pagination:
iv, 22 p.
Related Work(s):
Pages added/changed by ARLIS:
Notes:
All reports in the Susitna-Watana Hydroelectric Project Document series include an ARLIS-
produced title page and an ARLIS-assigned number for uniformity and citability. All reports
are posted online at http://www.arlis.org/resources/susitna-watana/
Susitna-Watana Hydroelectric Project
(FERC No. 14241)
Wetland Mapping Study
in the Upper and Middle Susitna Basin
Prepared for
Alaska Energy Authority
Prepared by
ABR, Inc.–Environmental Research & Services
February 2013
FINAL REPORT WETLAND MAPPING
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page i February 2013
TABLE OF CONTENTS
Summary ....................................................................................................................................... iv
1. Introduction ............................................................................................................................1
2. Study Objectives .....................................................................................................................1
3. Study Area ...............................................................................................................................1
4. Methods ...................................................................................................................................2
4.1. Deviations from the 2012 Study Plan ........................................................................2
4.2. Field Survey ..............................................................................................................3
4.3. Wetland Classification and Mapping ........................................................................5
4.4 Wetland Functional Assessment ...............................................................................6
5. Results ......................................................................................................................................7
5.1. Field Survey ..............................................................................................................7
5.1.1. Waters ...................................................................................................... 7
5.1.2. Wetlands .................................................................................................. 8
5.1.3. HGM Classes ........................................................................................... 8
5.2. Wetland Classification and Mapping ........................................................................9
6. Discussion ................................................................................................................................9
7. References .............................................................................................................................10
8. Tables .....................................................................................................................................12
9. Figures ...................................................................................................................................17
LIST OF TABLES
Table 1. Mean monthly air temperature and cumulative precipitation for two weather stations
nearest to the wetland mapping study area, Susitna-Watana Hydroelectric Project, Alaska,
2012. ...................................................................................................................................... 13
Table 2. Wetland classes following Cowardin et al. (1979) sampled within the wetland mapping
study area, Susitna-Watana Hydroelectric Project, Alaska, 2012......................................... 14
Table 3. Hydrogeomorphic (HGM) wetland classes sampled within the wetland mapping study
area, Susitna-Watana Hydroelectric Project, Alaska, 2012. ................................................. 16
FINAL REPORT WETLAND MAPPING
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page ii February 2013
LIST OF FIGURES
Figure 1. Study area and completed 2012 sampling transects for the Wetland Mapping Study,
Susitna-Watana Hydroelectric Project, Alaska. The Project area boundary shown is the
version dated October 26, 2012, but the 2-mile buffer for the study area was drawn from the
April 13, 2012 version of the Project area boundary. ........................................................... 18
Figure 2. Selection of wetland functional parameters to be used for the Susitna-Watana
Hydroelectric Project in relation to parameters used for other functional assessments in
Alaska. .................................................................................................................................. 19
Figure 3. Hydric soil indicator: A1 (Histosol) in the wetland mapping study area, 2012. .......... 20
Figure 4. Wetland hydrology indicators: A1 (High Water Table) and A2 (Saturation) in the
wetland mapping study area, 2012. ....................................................................................... 20
Figure 5. Typical R3UBH wetland (upper perennial stream) in the wetland mapping study area,
2012. ...................................................................................................................................... 21
Figure 6. Typical PEM1E wetland (wet sedge meadow) in the wetland mapping study area,
2012. ...................................................................................................................................... 21
Figure 7. Typical PSS1B wetland (willow scrub) in the wetland mapping study area, 2012. .... 22
FINAL REPORT WETLAND MAPPING
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page iii February 2013
LIST OF ACRONYMS AND SCIENTIFIC LABELS
Abbreviation Definition
ADNR Alaska Department of Natural Resources
AEA Alaska Energy Authority
APA Alaska Power Authority
ATV all-terrain vehicle
FERC Federal Energy Regulatory Commission
ºF degrees Farhenheit
ft feet, foot
GIS Geographic Information System
GPS global positioning system
HGM hydrogeomorphic
ILP Integrated Licensing Process
km kilometer
LiDAR Light Detection and Ranging
m meter(s)
NEPA National Environmental Policy Act
NRCS Natural Resources Conservation Service
NWI National Wetlands Inventory
Project Susitna-Watana Hydroelectric Project
PM&E protection, mitigation, and enhancement
PSP Proposed Study Plan
RM The distance of a point on a river measured in miles from the river's mouth along the
low-water channel, referencing those of the 1980s APA Project.
RSP Revised Study Plan
TNW Traditionally Navigable Water
USACE U.S. Army Corps of Engineers
USDA U.S. Department of Agriculture
USFWS U.S. Fish and Wildlife Service
FINAL REPORT WETLAND MAPPING
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page iv February 2013
SUMMARY
A wetland mapping and functional assessment study is being conducted for the Susitna-Watana
Hydroelectric Project to provide baseline information on existing wetlands and their functions in
the Project area. The information on existing wetlands and their functions derived from this
study will be necessary for assessing potential Project impacts to wetland resources and
supporting wetland permitting under Section 404 of the Clean Water Act. The Wetland Mapping
Study is designed as a multi-year study, with work to be conducted in 2012 through 2014. The
collection of field ground-reference data and the classification and mapping of wetlands in the
study area (see Figure 1) were initiated in 2012.
Thirty-six sampling transects were completed during the 2012 field season. Standard wetland
field determinations, as defined by the U.S. Army Corps of Engineers (USACE; 2007 Regional
Supplement criteria) were completed at 276 field plots, and field verifications (a rapid
assessment technique to confirm previously documented conditions) were performed at 85 field
plots along the transects. Additional data collected included physiography, geomorphic unit,
macrotopography, and microtopography; selected wetland function parameters to support the
wetland functional assessment; and observations of wildlife use or human activity. Field data for
the Wetland Mapping Study were collected simultaneously with the collection of data for the
Vegetation and Wildlife Habitat Mapping Study. Field data were used in conjunction with high-
resolution imagery to classify and map wetlands and waters within the study area according to
the methodology defined in the Revised Study Plan (RSP; see Section 11.7 in RSP; AEA 2012b).
As the mapping proceeds in 2013, wetland types will be classified based on a number of
landscape, geomorphic, hydrological, and biological variables, and will incorporate elements of
two wetland classification systems: National Wetlands Inventory (NWI) and hydrogeomorphic
(HGM). Information on vegetation types (Level IV classes of the Alaska Vegetation
Classification) also will be used in classifying wetlands. This integrated classification approach
is similar to a regional classification system developed for lowlands in the Cook Inlet Basin, and
will allow wetland classes developed for the Project to be cross-referenced with wetlands
identified in the Cook Inlet Basin. This approach was agreed upon during meetings with resource
management agencies regarding the wetland mapping study in spring 2012 (see Section 9.7 in
the Proposed Study Plan [PSP]; AEA 2012a).
As noted above, the wetlands data collected in 2012 represent only the first year of work in a
multi-year mapping study of wetlands for the Project. The data from 2012 will be combined with
those collected in 2013 and 2014 to prepare a complete wetlands map for the Project (see Section
11.7 in RSP). If warranted by the results of the 2012 work, the specific field and office methods
used to identify, delineate, and map wetlands within the study area may be refined (based on
consultation with AEA and other licensing participants).
The wetlands identified in the study area to-date typify this region of Alaska. Because of the
large size of the Project and study area, a number of different wetland and vegetation types have
been encountered, ranging from those comparable to the coastal Cook Inlet area (in the west near
Gold Creek) to those more typical of interior areas of Alaska (in the east near the Oshetna River
and the north near Cantwell).
FINAL REPORT WETLAND MAPPING
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 1 February 2013
1. INTRODUCTION
This report provides the results of the 2012 Wetland Mapping Study, based on work outlined in
the 2012 Wetland Mapping Study in the Upper and Middle Susitna Basin Study plan (AEA
2012c).
The Alaska Energy Authority (AEA) is preparing a License Application that will be submitted to
the Federal Energy Regulatory Commission (FERC) for the Susitna-Watana Hydroelectric
Project (Project) using the Integrated Licensing Process (ILP). The Project is located on the
Susitna River, an approximately 300-mile-long river in Southcentral Alaska. The Project’s dam
site would be located at river mile (RM) 184.
The Wetland Mapping Study is a multi-year study initiated in 2012. Two primary tasks were
started during 2012: (1) field ground-reference surveys were conducted to collect current data on
wetland occurrence and wetland functions, and (2) preliminary mapping of wetlands in the study
area (see Study Area below). This study provided data to inform the 2013–2014 licensing study
program, Exhibit E of the License Application, and FERC’s National Environmental Policy Act
(NEPA) analysis for the Project license.
2. STUDY OBJECTIVES
The overall goals of the Wetland Mapping Study are to prepare a baseline map of existing
wetland habitats in the Upper and Middle Susitna basin (upstream of Gold Creek) that could be
directly affected by Project development, and to determine the functions that each mapped
wetland type performs. This mapping information will be used in AEA’s License Application to
assess impacts to wetland resources from the proposed Project, and to develop protection,
mitigation, and enhancement (PM&E) measures, as appropriate. Additionally, the Wetland
Mapping Study will provide the baseline information necessary for preparing a wetland permit
application for the Project under Section 404 of the Clean Water Act.
The specific objectives of the Wetland Mapping Study are to identify, delineate, and map
wetlands in the Upper and Middle Susitna basin to reflect current conditions as indicated on
recent aerial imagery for the study area, and to determine and describe the functional values for
each of the mapped wetland types. The multi-year study was initiated in 2012 and will be
continued in 2013 and 2014. Results from the 2012 work will be used to fine-tune the field
investigations and the mapping of current wetland types in the study area.
3. STUDY AREA
The study area for the Wetland Mapping Study consists of a 2-mile buffer surrounding those
areas that would be directly altered or disturbed by development of the Project (Figure 1),
including three possible alternatives for road and transmission lines (Chulitna, Gold Creek, and
Denali), the proposed reservoir inundation area, dam site, and supporting infrastructure
surrounding the dam site. The Chulitna Corridor would include transmission lines and a road
running north of the Susitna River toward the west to connect to the Alaska Intertie and the
FINAL REPORT WETLAND MAPPING
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 2 February 2013
Alaska Railroad near the Chulitna station. Another east–west corridor configuration, the Gold
Creek Corridor, would follow a route south of the Susitna River running west to Gold Creek
station. A third corridor, the Denali Corridor, runs north and would connect the dam site to the
Denali Highway by road over a distance of about 44 miles. If transmission lines are run along the
Denali Corridor, they would also need to run west along the existing Denali Highway to connect
to the Alaska Intertie near the community of Cantwell. In areas paralleling the Susitna River
between the dam site and Gold Creek, wetlands within the 2-mile study area buffer will be
mapped up to the boundary of the Riparian Vegetation Study area. Wetlands in riparian areas
downstream of the proposed dam will be mapped in the Riparian Vegetation Study. Mapping
methods in the Wetland Mapping Study and Riparian Vegetation Study (see RSP Section 11.6 in
AEA 2012b) are compatible, and the final mapping will result in a seamless wetlands map for
the Project area, both above the proposed dam site and in riparian areas downstream of the dam
site.
High-resolution aerial imagery is required for wetland mapping, because wetlands can be
differentiated both from uplands and from other wetland types by subtle differences in color,
texture, and plant canopy, as well as hydrological indicators such as drainage patterns and
surface water connections. Suitable high-resolution imagery (0.3-meter to 1.0-meter [1-foot to
3.3-foot] pixel resolution) is not yet available for the entire study area, but it is anticipated that
additional imagery will be acquired during the 2013 field season (the new imagery will include
both natural color and infrared formats) (see RSP Section 11.7 in AEA 2012b). Thus, the
detailed mapping of wetlands conducted in 2012 is limited currently to those areas with high-
resolution imagery, which includes a section surrounding the Upper Susitna River (covers the
southwestern part of the reservoir inundation zone and small portions of the Gold Creek
corridor), and another section in the vicinity of Cantwell at the northern end of the Denali
corridor.
4. METHODS
In general, the wetlands mapping for the Project area will follow protocols developed by the U.S.
Fish and Wildlife Service (USFWS) National Wetlands Inventory (NWI) program (National
Wetlands Inventory Center 1995, Dahl et al. 2009). Wetland types will be classified based on a
number of landscape, geomorphic, hydrological, and biological variables, and will incorporate
elements of two wetland classification systems: NWI (Cowardin et al. 1979) and
hydrogeomorphic (HGM) (Brinson 1993). Information on vegetation types (Level IV classes of
the Alaska Vegetation Classification; Viereck et al. 1992) will also be used in classifying
wetlands. This integrated classification approach is similar to a regional classification system
developed for lowlands in the Cook Inlet basin (Gracz 2011), and will allow wetland classes
developed for the Project to be cross-referenced with wetlands identified in the Cook Inlet basin.
This approach was agreed to during meetings with resource management agencies regarding the
Wetland Mapping Study in spring 2012 (see RSP Section 9.7 in AEA 2012a).
4.1. Deviations from the 2012 Study Plan
The 2012 study plan for the Wetland Mapping Study (AEA 2012c) indicated that preliminary
wetlands mapping would be conducted prior to field surveys in areas where NWI mapping was
FINAL REPORT WETLAND MAPPING
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 3 February 2013
lacking but high-resolution imagery was available. The objective of the preliminary mapping
was to identify a set of characteristic wetland types within the study area to guide field survey
plot locations, and to allow field verification of the preliminary mapping. Instead, in 2012, field
plots were located within the prominent imagery signatures in each major physiographic type,
which often is the first step in a multi-year wetlands mapping project. In 2013 and 2014,
preliminary wetland mapping will be available to support the selection of field plots and
facilitate the field verification of the wetlands mapping. Thus, the lack of preliminary mapping
prior to the 2012 field surveys will not affect the quality or accuracy of the final wetlands map.
Additionally, no efforts were made to relocate the 1980s sampling locations during the 2012
field season as indicated in the 2012 study plan. Given the poor spatial quality of 1980s (pre-
global positioning system [GPS]) sampling locations and the logistical constraints associated
with the 2012 field activities, the 2012 field efforts were focused on acquiring current wetlands
data. Because the primary goal of this study is to develop a wetlands map based on current
conditions and because revisiting historic sampling locations will not increase the accuracy of
the new map, no future efforts will be made to revisit historic sampling locations (see RSP
Section 11.7 in AEA 2012b).
4.2. Field Survey
Field data were collected along transects designed to access the primary physiographic classes
(Alpine, Subalpine, Upland, Lowland, Lacustrine, and Riverine) in the study area, while
maximizing safety and efficiency. Transect length ranged from approximately 1.5 – 3.0
kilometers (0.93 – 1.86 miles) and 8–12 pre-selected field plot locations were allocated along
each transect. Transects were not always straight lines because they were designed specifically to
allow the sampling of different land cover types within the physiographic classes noted above.
Transect length and complexity were designed to allow a field team to complete data collection
along one transect per day. Field plots were pre-selected to facilitate the collection of ground-
reference data from as many wetland types as possible, identified by differences in imagery
signature color and texture, plant canopy, and surface relief, along with hydrological indicators
such as drainage patterns and surface water connections. Data were collected at the pre-selected
field plot locations and at additional plot locations established in the field (where new,
transitional, or under-sampled land cover types were encountered). Transects were located
(Figure 1) in those portions of the study area for which there currently is high-resolution aerial
imagery (see Study Area above). Six transects were located outside the Wetland Mapping Study
area, but within the Vegetation and Wildlife Habitat Mapping Study area (data for the two
studies were collected concurrently at each field plot to maximize the efficiency of the field
effort). Although six transects were located outside the Wetland Mapping Study area, those
transects include imagery signatures of wetland types that occur within the Wetland Mapping
Study area, so the field data collected can still be used to assist in the wetlands mapping effort.
Routine wetland determinations were performed following the U.S. Army Corps of Engineers
(USACE) three-parameter approach (Environmental Laboratory 1987; USACE 2007) at each
field plot location. To be classified as a wetland, a site must be dominated by hydrophytic plants,
have hydric soils, and show evidence of a wetland hydrologic regime. A Trimble® Nomad™
series mobile Geographic Information System (GIS) unit was used to record the wetlands data
(using the WetForm database) and the GPS coordinates of each field plot, and to provide access
to the aerial imagery in the field. WetForm is a proprietary relational database used to record
FINAL REPORT WETLAND MAPPING
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 4 February 2013
standard wetland determination data in the field, and facilitates the preparation of an electronic
version of the USACE-required dataform for each wetland determination plot (USACE 2007).
At each field plot, all wetland-determination data were recorded within a 10-meter (33-foot)
radius of homogenous vegetation, as specified by the 1987 Corps of Engineers Wetlands
Delineation Manual (Environmental Laboratory 1987), although the size and dimensions of the
field plots were modified where necessary to accurately characterize the plant community (e.g.,
narrow plots were used in some riverine habitats). The absolute cover of each vascular plant
species within the plot was visually estimated and the presence of hydrophytic vegetation was
determined using the Dominance Test (ratio of wetland versus upland dominant plants) and/or
the Prevalence Index (weighted average of all species present), using the wetland indicator status
per the 2012 National Wetland Plant List: Alaska (Lichvar and Kartesz 2012).
Hydric soils form under conditions of saturation, flooding, or ponding, which occur long enough
during the growing season to develop anaerobic conditions in the upper 12 inches of the soil.
Hydric soils often have thick organic deposits (histosols, histels, or histic epipedons; Figure 2) or
have a low-chroma mineral soil matrix color with redoximorphic features, indicating a reducing
environment. To assess the presence or absence of hydric soils, soil pits were excavated to
approximately 18 inches or to the depth of the active layer, if shallower, and the soil profile was
described. Key characteristics including color (Munsell Soil Color Charts 2009) and abundance
of redoximorphic features were recorded. Soil profile descriptions also were compared with
hydric soil criteria in the most current version of the Field Indicators of Hydric Soils in the
United States (USDA NRCS 2010).
Wetland hydrology is defined as the presence of flooded or ponded surface water or saturation
within the upper 12 inches of the soil profile for at least 14 consecutive days during the growing
season, and at a minimum frequency of 5 out of 10 years. To assess the presence or absence of
wetland hydrology, surface and subsurface, direct and indirect indicators were recorded at each
site, including surface water, saturated soils, presence of and depth to the water table (Figure 3),
drift or sediment deposits, drainage patterns, and geomorphic position, as summarized in the
Regional Supplement to the Corps of Engineers Wetlands Delineation Manual (USACE 2007).
Documentary photos of soils and vegetation were taken at each wetland determination plot.
Additional data collected at each plot included physiography, geomorphic unit, macrotopography
and microtopography; selected wetland function parameters to support the wetland functional
assessment; observations of wildlife use (e.g., trails, browse, scat) or human use (e.g., hunting
activities, all-terrain vehicle [ATV] trails); and the Level IV vegetation class of the Alaska
Vegetation Classification (Viereck et al. 1992; hereafter refered to as the Level IV vegetation
class).
In some cases, verification plots (a rapid assessment technique to provide replication for
previously documented conditions) were also sampled to collect additional data to support the
wetland mapping efforts. At verification plots, data on dominant vascular plant species, NWI
wetland classes, and Level IV vegetation classes, in addition to site photographs and GPS
coordinates, were recorded. Verification plots were typically conducted in areas where the
wetland or upland status had been documented in the data from formal wetland determination
plots. Data from the verification plots will be used to improve map accuracy by increasing the
number of documented wetland data elements tagged to particular aerial imagery signatures.
FINAL REPORT WETLAND MAPPING
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 5 February 2013
4.3. Wetland Classification and Mapping
Two high-resolution (0.3-meter to 1.0-meter [1-foot to 3.3-foot] pixel resolution) imagery
products suitable for mapping are currently available for the study area. The Matanuska-Susitna
Borough LiDAR (hereafter referred to as Mat-Su LiDAR) project imagery is a near-infrared,
color orthomosaic at 0.3-meter (1-foot) pixel resolution based on aerial photography obtained
between July and October 2010; it covers portions of the study area from Gold Creek through the
southwestern section of the inundation zone surrounding the Susitna River. The Denali Census
(hereafter referred to as Denali) orthorectified aerial imagery acquired in May through
September 2006 at a 1-meter (3.3-foot) pixel resolution is a true-color image product publicly
available, and is suitable for mapping the northern portions of the study area near Cantwell.
Where high-resolution imagery was available, the delineation of wetland boundaries was
initiated in 2012 using on-screen digitizing and ArcGIS software, which is the predominant
approach employed by the USFWS NWI program (Dahl et al. 2009). The minimum mapping
polygon size for wetlands, waters, and most upland areas is 0.5 acres (see RSP Section 11.7 in
AEA 2012b), although smaller polygons (0.1 acre) are being delineated for water bodies and
other wetlands of ecological importance, such as marsh habitats with standing water and
emergent vegetation. Wetland and upland boundaries are being delineated based on imagery
signature color and texture, plant canopy, and surface relief, along with hydrological indicators
such as drainage patterns and surface water connections.
Wetlands and waters are being categorized first following Cowardin et al. (1979) using
annotation developed by the NWI program, which describes the dominant vegetation and
hydrological regime. The Cowardin classification is a comprehensive system for the
classification of wetlands and deepwater habitats developed for the USFWS NWI program in
which wetlands are classified based on vegetation structure and hydrology, and on other
characteristics that are generally identifiable from aerial imagery. In addition to assigning an
NWI class, each wetland polygon was assigned a physiography class, a Level IV vegetation
class, and an HGM class. In Level IV vegetation classes, dominant plant species and vegetation
structure are used to categorize common vegetation types in Alaska. In the HGM system,
wetlands are classified into seven different categories based on geomorphic position and
hydrologic characteristics, as defined by Brinson (1993) and modified by Smith et al. (1995) for
functional assessments. Functions and ecological services provided by wetlands vary by
geomorphic position and hydrology, and the HGM classification helps identify differences in
both wetland functions and their magnitude. For example, a depressional wetland has a much
greater capacity to retain sediment than a slope wetland due to its closed or semi-enclosed
contours, which a slope wetland lacks. Thus, while some wetlands may share a similar NWI
class, differences in HGM classes can be used to distinguish them by their functional
characteristics.
The four attributes (NWI, physiography, Level IV vegetation, and HGM class) assigned to each
map polygon will be combined to produce a set of unique wetland types, which will then be
aggregated into broader, ecologically related categories for functional assessment purposes.
Additional features, such as the presence or absence of permafrost, will be included in this
aggregation to allow greater distinctions between wetlands in terms of their functional capacity.
FINAL REPORT WETLAND MAPPING
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 6 February 2013
4.4 Wetland Functional Assessment
Based on discussions with resource management agencies while preparing the Wetland Mapping
Study Plan (see RSP Section 11.7 in AEA 2012b), wetland functions in the study area will be
assessed using HGM principles (Smith et al. 1995). Similar to formal HGM methodologies,
HGM classes as defined by Brinson (1993) (e.g., depressional, slope, lacustrine fringe) will be
used. The functional capacity of each wetland type will be assessed following Magee’s (1998)
rapid-assessment procedure, which involves incorporating field data into HGM-specific models.
The Magee (1998) rapid-assessment procedure provides a means for collecting field data
relevant to HGM assessments within a time frame compatible with the schedule for the Project.
After reviewing wetland functional assessments conducted elsewhere in Alaska (Figure 2) and
consulting with resource management agencies, the following set of 10 wetland functions were
selected for evaluation:
• Modification of groundwater discharge
• Modification of groundwater recharge
• Storm and flood-water storage
• Modification of stream flow
• Modification of water quality, including sediment retention and nutrient and toxicant
removal
• Export of detritus
• Contribution to abundance and diversity of wetland vegetation
• Fish and wildlife habitat
• Consumptive uses
• Uniqueness
These functions will be evaluated using a combination of field data from this and other Project
studies (AEA 2012b), as well as GIS analysis of the spatial occurrence of the wetland types
identified in the study area. As part of the 2012 field survey effort, data reflecting wetland
functional capacity were collected at each wetland determination plot for hydrologic (e.g., pH,
water regime, presence of seeps or springs), soil (e.g., organic or mineral), and vegetation (e.g.,
dominant wetland type, vegetation interspersion) variables following Magee (1998). These data
(combined with data collected in 2013 and 2014) will be run through HGM-class-specific
models (Magee 1998) to determine a base level of functional capacity for each mapped wetland
type for 7 of the 10 functions (all except fish and wildlife habitat, consumptive uses, and
uniqueness). Magee (1998) does not include models for consumptive uses or uniqueness. If
possible, consumptive uses will be evaluated using spatially explicit, Project-specific
recreational- and subsistence-use data (see Sections 12.5 and 14, AEA 2012b) to indicate which
general regions in the study area are used currently (actual use for recreation and subsistence
activities). Wetland uniqueness will be evaluated after wetland mapping is complete and will be
based on the frequency of occurrence, relative to other wetland types and the extent to which the
“rare” wetland types are also regionally scarce. The fish and wildlife and habitat function will be
assessed by incorporating Project-specific fish and wildlife occurrence data to derive spatially
explicit functional capacity indices indicating which specific wetlands in the study area provide
those habitat functions and to what degree. The presence or absence of permafrost also will be
included in the classification of wetland types, thus allowing distinctions between the functional
capacities of permafrost and non-permafrost wetlands.
FINAL REPORT WETLAND MAPPING
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 7 February 2013
5. RESULTS
During summer 2012, two teams of two scientists collected wetlands, vegetation, and wildlife
habitat field data during two survey periods: June 19–27 and July 30–August 8. Survey dates
were selected to be well within the median dates of the onset of vegetation green-up in spring
and vegetation senescence in fall, as specified in the USACE manual (2007). Two weather
stations closest to the Project area indicated that temperatures during the 2012 field season were
near average (Table 1). Precipitation in June was more than double the 30-year mean at the
Chulitna River station and nearly double that at the Cantwell 4E station. Precipitation for the
remaining months of the growing season, however, was well below the 30-year mean.
5.1. Field Survey
Thirty-six transects were sampled during the 2012 field season. Standard USACE field wetland
determinations were completed at 276 sites and verification plots at 85 sites along the 36
transects. Of the 276 standard wetland determinations, 152 were uplands (non-wetland) and 124
were wetlands or waters. The 124 wetland or water determination plots were categorized into 24
NWI (Table 2) and 4 HGM (Table 3) wetland classes. The 85 verification plots provided
replicate sampling for the imagery signatures of 44 upland sites and 41 wetlands or water bodies.
5.1.1. Waters
The Susitna River is classified as a Traditionally Navigable Water (TNW) from Cook Inlet to the
confluence with Portage Creek. The Nenana River, located in the northern portion of the study
area, is classified as potentially navigable (ADNR 2012). Both rivers are upper perennial (R3)
riverine systems, characterized by year-round, high-gradient, and high-velocity flow. Neither
river is tidally influenced within the study area. As expected for high-velocity systems, there is
little floodplain development and substrates are generally coarse (cobbles to boulders). Gravel
bars and islands are frequently flooded wetland communities, dominated by vegetation that can
grow in both wetland or upland settings. These communities have surface water (flooding) for
brief periods during the growing season, but the groundwater table is usually well below the
surface.
Additional Waters of the U.S. within the study area include named and unnamed tributaries of
the Susitna and Nenana rivers. Upper perennial waters (R3UBH) were documented with eight
verification plots and one wetland determination plot. These waters were typically 3–6 meters
(10–20 feet) wide at bankfull, with gravel to boulder substrates, and cover provided by
overhanging vegetation, undercut banks, and large woody debris (Figure 4).
Intermittent waters (R4SBC) were documented with four verification plots. These small
intermittent tributaries were typically observed flowing from seeps or springs on hillsides, with
surface flow present for short stretches along less steep terrain.
Freshwater ponds (PUBH) were documented with one verification plot. The documented pond
was small (<1 acre), and was unvegetated with fine substrates.
FINAL REPORT WETLAND MAPPING
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 8 February 2013
5.1.2. Wetlands
The most commonly sampled NWI wetland class was palustrine seasonally flooded/saturated
persistent emergent marsh (PEM1E; n=29 wetland determination plots; Figure 5). PEM1E
communities were frequently dominated by Carex aquatilis, Eriophorum russeolum,
Trichophorum cespitosum, or T. alpinum. Surface water was observed at all PEM1E
communities, and many had indicators reflecting a strongly reducing environment, such as a
hydrogen sulfide odor or iron deposits (flocculated iron and a biogenic sheen on standing water).
PEM1E communities included flooded, beaver-altered meadows; reticulated fens; floating
Sphagnum mats adjacent to kettle ponds; or vegetated mid-channel interfluves in braided stream
systems.
The next most commonly sampled NWI class was palustrine saturated broadleaf deciduous
scrub-shrub (PSS1B; n=23 wetland determination plots; Figure 6). PSS1B communities were
frequently dominated by Salix pulchra, S. barclayi, S. commutata, Alnus crispa, Betula nana,
and Vaccinium uliginosum. Saturated soils were observed at most PSS1B wetlands, with a few
showing oxidized rhizospheres around living roots or the presence of reduced iron. PSS1B sites
included toeslope wetlands, discharge slopes, and riparian corridors. Seasonally
flooded/saturated broadleaf deciduous scrub-shrub wetlands (PSS1E; n=8) were also found
throughout the study area, and were distinguished from PSS1B wetlands by the presence of
surface water or indications of previous flooding. These seasonally flooded/saturated wetland
types were dominated by a variety of Salix species and occurred on interfluves in low-lying
braided stream drainages and in toeslope areas.
Six wetland determination plots were recorded in palustrine saturated needleleaf forest wetlands
(PFO4B). All sampled PFO4B wetlands were open canopy or woodland Picea mariana forests,
with understories frequently dominated by Vaccinium uliginosum, V. vitis-idaea, and Equisetum
species. These forested wetlands occurred most often in toeslope areas.
Over half of the field plots sampled within the study area were uplands (non-wetlands). Dwarf-
shrub communities were the predominant alpine non-wetland community sampled. Field plots in
subalpine non-wetland communities were nearly evenly divided among dwarf shrub, low birch–
ericaceous, and tall alder and/or willow communities. Field plots in riverine, upland, and lowland
physiographic non-wetlands were a mix of Picea glauca woodlands, open canopy Picea glauca–
Betula neoalaskana forests, low birch–ericaceous shrub, and tall alder and/or tall willow
communities.
5.1.3. HGM Classes
Four HGM wetland classes (slope, depressional, riverine, and lacustrine fringe) were sampled
during 2012 (Table 3). Slope wetlands were the most commonly sampled HGM class (n=72
wetland determination plots), and preliminary mapping indicates that it is the most common
HGM class in the study area. Many wetlands in the study area occur on gently sloping terrain or
toeslopes where groundwater discharges. HGM slope wetlands comprised a variety of NWI
classes, from palustrine permanently flooded persistent emergent marsh (PEM1H) to palustrine
saturated needleleaf forest wetlands (PFO4B).
Wetlands that fell under the Riverine HGM class (n=18 wetland determination plots) were
sampled within the Susitna River floodplain, as well as smaller tributaries to the Susitna and
FINAL REPORT WETLAND MAPPING
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9 February 2013
Nenana rivers, and included upper perennial rivers (R3UBH and R3USC), and both emergent
(PEM) and scrub-shrub (PSS) palustrine NWI codes.
Field plots in lacustrine-fringe wetlands were associated with lakes and ponds, and were
typically seasonally to permanently flooded persistent emergent palustrine NWI classes.
Depressional wetlands include a variety of NWI classes, from permanently flooded persistent
emergent marsh (PEM1H) to palustrine saturated broadleaf scrub-shrub wetlands (PSS1B).
5.2. Wetland Classification and Mapping
After the 2012 field season, all field ground-reference data were used in conjunction with the
Mat-Su LiDAR imagery to initiate the mapping of wetlands and waters within the study area.
The mapping of wetlands and waters (and vegetation and wildlife habitats) will continue through
the winter and spring of 2013 using the imagery described in RSP sections 11.5 and 11.7 in AEA
2012b. Additional high-resolution imagery acquired in 2013 will be used to continue the
mapping process in fall and early winter 2013. The preliminary wetland types classified and
mapped in the study area will be presented for review in the Initial Study Report, to be filed with
FERC February 2014.
6. DISCUSSION
In 2012, 24 NWI wetland classes were documented in the study area, with PSS1B and PEM1E
being the most commonly sampled. Through the continued wetland mapping efforts in 2013, the
full range of wetland types within the study area will be determined, and pre-selected field plot
locations will be allocated for the 2013–2014 field programs to ensure that any unsampled or
undersampled NWI classes are documented with wetland determination plots.
Upper perennial and intermittent rivers and streams (R3UBH and R4SBC, respectively) were
documented with field data in 2012. Initial mapping efforts and review of aerial imagery indicate
that these are the most common riverine systems within the study area. However, review of
aerial imagery also indicates that lower perennial waters (R2UBH) are present within the study
area, meandering through low-lying scrub wetlands. R2UBH systems comprise low-gradient,
low-velocity waters with fine substrates (typically mud or sand). While no field plots were
sampled to document R2UBH waters in 2012, pre-selected plots will be allocated for the 2013–
2014 field programs to adequately characterize these systems in the study area.
In the Cowardin classification, lacustrine (lake) systems are distinguished from palustrine (pond)
systems based on size and depth, with lacustrine systems being >20 acres in size and/or >2
meters (6.6 feet) deep in the deepest part of the basin at low water. A review of the aerial
imagery indicates that the majority of water bodies within the study area are freshwater ponds
(PUBH), with a few scattered large lakes (L1UBH), none of which were designated as navigable
(ADNR 2012). Pre-selected field plots will be established for the 2013–2014 field programs to
adequately characterize ponds and lakes within the study area.
Four HGM wetland classes (slope, depressional, riverine, and lacustrine fringe) were sampled in
2012. While there were many level to nearly level wetlands sampled during the 2012 field
program, no wetlands were assigned to the flat HGM class. The flat HGM class is reserved for
precipitation-driven wetlands with primarily vertical hydrodynamics. Such wetlands are
FINAL REPORT WETLAND MAPPING
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 10 February 2013
commonly located in large relict lake bottoms or old floodplain terraces; the extensive peatlands
on the western Kenai Peninsula in Alaska are an example of HGM flat wetlands. The level to
nearly level wetlands sampled in the study area in 2012 were classified as HGM slope wetlands,
located in toeslope areas where hydrology is dominated by groundwater discharge. Typical
vegetation in these areas included numerous fen indicators or plant species such as Eriophorum
angustifolium, Tricophorum cespitosum, and Betula nana that require more mineral-rich
conditions, which are indicative of a strong groundwater component to the wetland hydrology.
7. REFERENCES
ADNR (Alaska Department of Natural Resources). 2012. Navigable Waters Web Map.
http://www.navmaps.alaska.gov/navwatersmap/ Accessed 19 September 2012.
AEA (Alaska Energy Authority). 2012a. Proposed Study Plan: Susitna-Watana Hydroelectric
Project FERC Project No. 14241. July 2012. Prepared for the Federal Energy Regulatory
Commission by the Alaska Energy Authority, Anchorage, Alaska.
AEA. 2012b. Wetland Mapping Study in the Upper and Middle Susitna Basin. Revised Study
Plan: Susitna-Watana Hydroelectric Project FERC Project No. 14241, Section 11.7.
December 2012. Prepared for the Federal Energy Regulatory Commission by the Alaska
Energy Authority, Anchorage, Alaska. http://www.susitna-watanahydro.org/wp-
content/uploads/2012/12/07-RSP-Dec2012_7of8-Sec-11-12-BotanicalthroughRecreation-
v2.pdf.
AEA. 2012c. Wetland Mapping Study: Susitna-Watana Hydroelectric Project FERC Project No.
14241. May 2012.
Brinson, M.M. 1993. A hydrogeomorphic classification for wetlands. Technical Report WRP–
DE–4, U.S. Army Corps of Engineers, Army Engineer Waterways Experiment Station,
Vicksburg, MS.
Cowardin, L. M., V. Carter, F. C. Golet, and E. T. LaRoe. 1979. Classification of wetlands and
deepwater habitats of the United States. Northern Prairie Publication 0421, U.S.
Department of the Interior, Fish and Wildlife Service, Washington, D.C. 131 pp.
Dahl, T. E., J. Dick, J. Swords, and B. O. Wilen. 2009. Data collection requirements and
procedures for mapping wetland, deepwater and related habitats of the United States.
Division of Habitat and Resource Conservation, National Standards and Support Team,
Madison, WI. 85 p.
(http://www.fws.gov/wetlands/_documents/gNSDI/DataCollectionRequirementsProcedur
es.pdf)
Environmental Laboratory. 1987. Corps of Engineers Wetlands Delineation Manual. Technical
Report Y-87-1. Vicksburg, MS: U.S. Army Engineer Waterways Experiment Station.
(http://el.erdc.usace.army.mil/wetlands/pdfs/wlman87.pdf)
Gracz, M. 2011. Cook Inlet Lowland Wetlands. Available from http://cookinletwetlands.info/
Accessed September 2012.
FINAL REPORT WETLAND MAPPING
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 11 February 2013
Lichvar R. W. and J. T. Kartesz. 2012. North American Digital Flora: National Wetland Plant
List, version 2.4.0 [Online] https://wetland_plants.usace.army.mil. U.S. Army Corps of
Engineers, Engineer Research and Development Center, Cold Regions Research and
Engineering Laboratory, Hanover, NH, and BONAP, Chapel Hill, NC. Accessed June
2012.
Magee, D. W. 1998. A rapid procedure for assessing wetland functional capacity based on
hydrogeomorphic (HGM) classification. Bedford, NH.
Munsell Soil Color Charts. 2009. Revised edition. Gretag Macbeth, New Windsor, NY.
National Climatic Data Center (NCDC) U.S. Department of Commerce. 2012. Climate Data
Online http://www.ncdc.noaa.gov/cdo-web/
National Wetlands Inventory Center. 1995. Photointerpretation conventions for the National
Wetlands Inventory, USFWS. St. Petersburg, FL. 60 pp.
Smith, R. D., A. Ammann, C. Bartoldus, and M. M. Brinson. 1995. An approach for assessing
wetland functions using hydrogeomorphic classification, reference wetlands, and
functional indices. Technical Report WRP–DE–9, U.S. Corps of Engineers, Army
Engineer Waterways Experiment Station, Vicksburg, MS.
USACE (U.S. Army Corps of Engineers). 2007. Regional supplement to the Corps of Engineers
Wetland Delineation Manual: Alaska Region (Version 2.0). ERDC/EL TR-07-24.
September 2007. Wetlands Regulatory Assistance Program. U.S. Army Engineer
Research and Development Center, Vicksburg, MS. 130 pp.
USDA, NRCS (U.S. Department of Agriculture, Natural Resources Conservation Service). 2010.
Field Indicators of Hydric Soils in the United States, Version 7.0. L.M. Vasilas, G.W.
Hurt, and C.V. Noble (eds.). USDA, NRCS, in cooperation with the National Technical
Committee for Hydric Soils.
Viereck, L. A., C. T. Dyrness, A. R. Batten, and K. J. Wenzlick. 1992. The Alaska vegetation
classification. Gen. Tech. Rep. PNW-GTR-286. Portland, OR: U.S. Department of
Agriculture, Forest Service, Pacific Northwest Research Station. 278 pp.
FINAL REPORT WETLAND MAPPING
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 12 February 2013
8. TABLES
FINAL REPORT WETLAND MAPPING
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 13 February 2013
Table 1. Mean monthly air temperature and cumulative precipitation for two weather stations nearest to the wetland
mapping study area, Susitna-Watana Hydroelectric Project, Alaska, 2012.
Mean Air Temperature (° F) Precipitation (inches)
Station 1 Month 30-yr Mean 2012 Anomaly 30-yr Mean 2012 Anomaly
Cantwell 4E April 27.2 30.7 3.5 0.71 1.14 0.43
May 41.4 40.3 –1.1 0.77 0.59 –0.18
June 51.3 51.3 0.0 1.87 3.22 1.35
July 55.2 52.2 –3.0 2.53 1.29 –1.24
August 50.6 50.4 –0.2 3.24 1.55 –1.69
Chulitna River April 30.6 36.0 5.4 1.38 0.53 –0.85
May 42.8 41.7 –1.1 1.03 0.59 –0.44
June 52.8 52.0 –0.8 1.65 3.74 2.09
July 55.5 52.3 –3.2 3.92 2.30 –1.62
August 51.8 51.3 –0.5 5.83 4.71 –1.12
Notes:
1 Source: National Climatic Data Center (NCDC) U.S. Department of Commerce. 2012. Climate Data Online
http://www.ncdc.noaa.gov/cdo-web/
FINAL REPORT WETLAND MAPPING
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 14 February 2013
Table 2. Wetland classes following Cowardin et al. (1979) sampled within the wetland mapping study area, Susitna-
Watana Hydroelectric Project, Alaska, 2012.
Cowardin Wetland Class Code n
Palustrine
Persistent emergent
Saturated PEM1B 8
Seasonally flooded/saturated PEM1E 29
Semipermanently flooded PEM1F 11
Permanently flooded PEM1H 4
Nonpersistent emergent
Seasonally flooded/saturated PEM2E 1
Persistent emergent/broadleaf deciduous scrub-shrub
Saturated PEM1/SS1B 5
Seasonally flooded/saturated PEM1/SS1E 4
Permanently flooded PEM1/SS1H 1
Broadleaf deciduous/broadleaf evergreen scrub-shrub
Saturated PSS1/3B 1
Broadleaf deciduous scrub-shrub/persistent emergent
Saturated PSS1/EM1B 3
Seasonally flooded PSS1/EM1C 1
Seasonally flooded/saturated PSS1/EM1E 5
Broadleaf evergreen scrub-shrub/persistent emergent
Saturated PSS3/EM1B 1
Broadleaf deciduous scrub-shrub
Saturated PSS1B 23
Seasonally flooded PSS1C 2
Seasonally flooded/saturated PSS1E 8
Broadleaf evergreen/broadleaf deciduous scrub-shrub
Saturated PSS3/1B 1
Broadleaf evergreen/needleleaf evergreen scrub-shrub
Saturated PSS3/4B 1
Broadleaf evergreen scrub-shrub
Saturated PSS3B 1
Needleleaf evergreen scrub-shrub
Saturated PSS4B 3
Seasonally flooded/saturated PSS4E 1
Needleleaf evergreen forest
Saturated PFO4B 6
Riverine
FINAL REPORT WETLAND MAPPING
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 15 February 2013
Cowardin Wetland Class Code n
Upper perennial unconsolidated bottom R3UBH 1
Upper perennial unconsolidated shore R3USC 3
Upland (non-wetland) U 152
Total 276
FINAL REPORT WETLAND MAPPING
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 16 February 2013
Table 3. Hydrogeomorphic (HGM) wetland classes sampled within the wetland mapping study area, Susitna-Watana
Hydroelectric Project, Alaska, 2012.
HGM Class Geomorphology Hydrology Example
Slope Steep hillsides to moderate slopes, lacking
closed contours
Groundwater discharge. Flow is
unidirectional with horizontal
hydrodynamics.
Toeslope discharge
wetland
Depressional Topographic depressions, which may have
any combination of inlets and outlets.
Groundwater discharge, interflow and
overland flow from adjacent uplands.
Direction of flow is generally from the
surrounding uplands to the center of the
depression. Vertical hydrodynamics.
Kettle wetland
Riverine Flood plains and riparian corridors.
Replaced by Slope or Depressional
wetlands where channel morphology
disappears.
Overbank flow from a channel. Flow is
generally unidirectional, horizontal
hydrodynamics.
Relict oxbow
wetland
Lacustrine Fringe Adjacent to a lake. Water elevation of lake maintains water
table in wetland. Flow is bidirectional
with horizontal hydrodynamics.
Floating Sphagnum
mat at lake fringe
FINAL REPORT WETLAND MAPPING
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 17 February 2013
9. FIGURES
FINAL REPORT WETLAND MAPPING
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 18 February 2013
Figure 1. Study area and completed 2012 sampling transects for the Wetland Mapping Study, Susitna-Watana Hydroelectric Project, Alaska. The Project area
boundary shown is the version dated October 26, 2012, but the 2-mi le buffer for the study area was drawn from the April 13, 2012 version of the Project area boundary.
FINAL REPORT WETLAND MAPPING
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 19 February 2013
Figure 2. Selection of wetland functional parameters to be used for the Susitna-Watana Hydroelectric Project in relation to parameters used for other functional
assessments in Alaska.
Wetland Functional Assessment Methods
HGM (Slope/Flat Wetlands)
• Soil Profile Integrity
• Characteristic Soil Thermal Regime
• Surface and Near Surface Water
Storage
• Cycling of elements and compounds
• Organic carbon export
• Plant Community
• Faunal Habitat Components
• Interspersion and connectivity
Interior Alaska
• Discharge of water to downgradient
systems
• Surface and shallow subsurface
water storage
• Particulate retention
• Organic carbon export
• Cycling of elements and compounds
• Maintenance of characteristic plant
communities
• Maintenance of characteristic habitat
structures
• Interspersion and connectivity
• Contribution to groundwater
• Transmission of groundwater
• Streamflow moderation
• Floodflow alteration
• Sediment/Toxicant/Pathogen
retention
• Sediment shoreline stabilization
• Nutrient
removal/Retention/Transformation
• Foodchain support
• Anadromous fish habitat
• Habitat and maintenance of
biodiversity
• Habitat for species of interest
• Recreation
• Consumptive uses
• Education
• Visual quality/Aesthetics
• Cultural and historical significance
• Uniqueness
Mat-Su Wetlands
Functions and Values
• Modification of groundwater
discharge
• Modification of groundwater recharge
• Storm and flood-water storage
• Modification of stream flow
• Modification of water quality,
including sediment retention and
nutrient and toxicant removal
• Export of detritis
• Contribution to abundance and
diversity of wetland vegetation
• Fish and wildlife habitat
• Consumptive uses
• Uniqueness
Susitna-Watana
Functions and Values
FINAL REPORT WETLAND MAPPING
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 20 February 2013
Figure 3. Hydric soil indicator: A1 (Histosol) in the wetland mapping study area, 2012.
Figure 4. Wetland hydrology indicators: A1 (High Water Table) and A2 (Saturation) in the wetland
mapping study area, 2012.
FINAL REPORT WETLAND MAPPING
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 21 February 2013
Figure 5. Typical R3UBH wetland (upper perennial stream) in the wetland mapping study
area, 2012.
Figure 6. Typical PEM1E wetland (wet sedge meadow) in the wetland mapping study area, 2012.
FINAL REPORT WETLAND MAPPING
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 22 February 2013
Figure 7. Typical PSS1B wetland (willow scrub) in the wetland mapping study area, 2012.