HomeMy WebLinkAboutSuWa37Alaska Resources Library & Information Services
Susitna-Watana Hydroelectric Project Document
ARLIS Uniform Cover Page
Title:
Thermal infrared remote sensing pilot test
SuWa 37
Author(s) – Personal:
Author(s) – Corporate:
Prepared by URS Corporation
Watershed Sciences, Inc.
AEA-identified category, if specified:
2012 Environmental Studies
AEA-identified series, if specified:
Series (ARLIS-assigned report number):
Susitna-Watana Hydroelectric Project document number 37
Existing numbers on document:
Published by:
[Anchorage, Alaska : Alaska Energy Authority, 2013]
Date published:
February 2013
Published for:
Prepared for Alaska Energy Authority
Date or date range of report:
Volume and/or Part numbers:
Final or Draft status, as indicated:
Final
Document type:
Pagination:
iv, 22, [1] p.
Related work(s):
Thermal infrared remote sensing pilot test - mapbook
(SuWa 38)
Pages added/changed by ARLIS:
Notes:
All reports in the Susitna-Watana Hydroelectric Project Document series include an ARLIS-
produced cover page and an ARLIS-assigned number for uniformity and citability. All reports
are posted online at http://www.arlis.org/resources/susitna-watana/
Susitna-Watana Hydroelectric Project
(FERC No. 14241)
Thermal Infrared Remote Sensing Pilot Test
Prepared for
Alaska Energy Authority
Prepared by
URS Corporation
Watershed Sciences Inc.
February 2013
FINAL REPORT THERMAL INFRARED REMOTE SENSING PILOT TEST STUDY
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page i February 2013
TABLE OF CONTENTS
Summary ....................................................................................................................................... iv
1. Introduction ........................................................................................................................1
2. Study Objectives.................................................................................................................1
3. Study Area ..........................................................................................................................1
4. Methods ...............................................................................................................................2
4.1. Instrumentation ..................................................................................................2
4.2. Image Collection ................................................................................................2
4.3. Ground Control ..................................................................................................2
4.4. Weather and Flow ..............................................................................................2
4.5. Surface Temperatures ........................................................................................3
4.6. Expected Accuracy ............................................................................................3
4.7. Surface Conditions .............................................................................................3
4.8. Feature Size and Resolution...............................................................................3
4.9. Image Uniformity...............................................................................................3
4.10. Temperatures and Color Ramps.........................................................................4
4.11. Sensor Calibration ..............................................................................................4
4.12. Geo-referencing .................................................................................................4
4.13. Geo-rectification ................................................................................................4
4.14. Interpretation and Sampling ...............................................................................5
4.15. Temperature Profiles ..........................................................................................5
5. Deviations from Study Plan ..............................................................................................7
6. Results .................................................................................................................................7
7. Discussion............................................................................................................................8
8. References ...........................................................................................................................8
9. Tables ..................................................................................................................................9
10. Figures ...............................................................................................................................13
FINAL REPORT THERMAL INFRARED REMOTE SENSING PILOT TEST STUDY
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page ii February 2013
LIST OF TABLES
Table 1. Surveyed Stream Lengths and Acquisition Dates............................................................ 9
Table 2. Summary of TIR Sensor Specifications ........................................................................... 9
Table 3. Summary of Thermal Image Acquisition Parameters ...................................................... 9
Table 4. Weather Conditions on the Survey Dates in Talkeetna, Alaska .................................... 10
Table 5. Comparison of radiant temperatures derived from the TIR images and kinetic
temperatures from the in-stream sensors .............................................................................. 11
Table 6. Summary of Information Provided in Appendix A ........................................................ 12
LIST OF FIGURES
Figure 1. Susitna River sections surveyed in October 2012. ....................................................... 13
Figure 2. Bell Jet Ranger equipped with mounted FLIR sensor. ................................................. 16
Figure 3. Thermal image locations. ............................................................................................. 16
Figure 4. Location of temperature sensors used for calibration. .................................................. 17
Figure 5. Examples of different color ramps applied to the same TIR image. ............................ 18
Figure 6. Example of Appendix A map. ...................................................................................... 18
Figure 7. TIR/True Color Image Comparison. ............................................................................ 19
Figure 8. Longitudinal temperature profile for the Susitna River and sampled inflows. ............ 20
Figure 9. The TIR images of three significant tributaries to the Susitna River. .......................... 21
Figure 10. Junction between acquisition days October 17 and 18, 2012. .................................... 22
APPENDICES
Appendix A. TIR Field Data
FINAL REPORT THERMAL INFRARED REMOTE SENSING PILOT TEST STUDY
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page iii February 2013
LIST OF ACRONYMS AND SCIENTIFIC LABELS
Abbreviation Definition
µm micrometer
AEA Alaska Energy Authority
AGL above ground level
oC degrees Celsius
EO External Orientation
FERC Federal Energy Regulatory Commission
ft feet
GCP ground control points
GIS geographic information system
GPS Global Positioning System
ILP Integrated Licensing Process
ºK degrees Kelvin
m meters
NEPA National Environmental Policy Act
Project Susitna-Watana Hydroelectric Project
RM river mile
TIR Thermal Infrared Remote
WSI Watershed Sciences Inc.
FINAL REPORT THERMAL INFRARED REMOTE SENSING PILOT TEST STUDY
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page iv February 2013
SUMMARY
This report provides the results of the 2012 Thermal Infrared Remote (TIR) Sensing Pilot Test.
The purpose of this study was to attempt to determine locations with large groundwater influence
along the Susitna River from Talkeetna to the proposed Project site (88 miles), using the
differential in temperature between warm groundwater and colder surface water. The survey was
conducted over a 4-day period in October 2012. Images were collected with a FLIR system’s
SC6000 sensor mounted on the underside of a Bell Jet Ranger Helicopter. To maximize thermal
contrast the TIR sensor was flown during early morning when solar loading was minimized. In-
stream sensors in the mainstem Susitna were used for calibrating and verifying the thermal
accuracy of the TIR imagery.
Over 500 areas of increased groundwater activity were seen in the thermal imagery from large
sloughs to small hyporheic seeps. The bulk of the groundwater activity (>90 percent) was seen
between the Chulitna River and Slough 21 (RM 98-143). While the groundwater could be easily
discerned in the imagery, the longitudinal temperature profile of the mainstem of the river is less
informative due to the minimal fluctuations in bulk water temperatures. Apparent stream
temperature changes of < 0.5°C (0.5 ºK) are not considered significant unless associated with a
surface inflow (e.g., tributary).
The prevalence of groundwater downstream of RM 140 does appear to impact bulk water
temperatures by increasing the overall temperature. The upward slope seen in the profile,
particularly between Deadhorse Creek (RM 121) and Lane Creek (RM 113.5), is a reflection of
this increase in temperatures. Temperatures increase almost 1°C (1.0 ºK) along this length of
river.
Though it is not obvious in the longitudinal profile, Lane Creek (113.5), Lower Portage Creek,
(RM 117.6) and the Indian River (138.6) are all contributing significantly warmer water to the
mainstem. Ten sloughs of significant size and thermal influence were also noted in the imagery
including Slough 8A (RM 126), Slough 9 (RM 129.2), and Slough 21 (RM 142).
FINAL REPORT THERMAL INFRARED REMOTE SENSING PILOT TEST STUDY
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 1 February 2013
1. INTRODUCTION
This report provides the results of the 2012 Thermal Infrared Remote (TIR) Sensing Pilot Test.
The Alaska Energy Authority (AEA) is preparing a License Application that will be submitted to
the Federal Energy Regulatory Commission (FERC) for the Susitna-Watana Hydroelectric
Project (Project) using the Integrated Licensing Process (ILP). The Project is located on the
Susitna River, an approximately 300-mile-long river in Southcentral Alaska. The Project’s dam
site would be located at river mile (RM) 184. This study provides data to inform the 2013–2014
licensing study program, Exhibit E of the License Application, and FERC’s National
Environmental Policy Act (NEPA) analysis for the Project license.
Airborne TIR remote sensing has proven to be an effective method for mapping spatial
temperature patterns in rivers and streams. These data are used to establish baseline conditions
and direct future ground level monitoring. The TIR imagery illustrates the location and thermal
influence of point sources, tributaries, and surface springs. When combined with other spatial
data sets, TIR data also illustrate reach-scale thermal responses to changes in morphology,
vegetation, and land use.
The thermal differential between bulk water temperatures in the Susitna and subsurface
discharges are approximately 3°C during the fall months with the groundwater discharge
typically being warmer than in-stream temperatures. Many studies have successfully used this
type of work to delineate groundwater contribution to surface water. However, this type of study
has rarely been performed in Alaska, and the temperature differential between surface water and
groundwater is not as large as in other areas of the United States. For this reason, this study was
considered a pilot test for the application of this technology to other parts of the Susitna River.
2. STUDY OBJECTIVES
The objectives of this study were as follows:
1. Collect thermal imagery from Talkeetna to the Watana Dam site during the late fall when
the temperature differential between surface water and groundwater was at a maximum;
and
2. Map the spatial dynamics and magnitude of groundwater discharge to establish baseline
data for assessing the availability and spatial extent of thermal refugia in the Middle
Susitna River.
3. STUDY AREA
The study area for this phase of the study includes the entire Middle River Segment of the
Susitna River from the confluence with the Chulitna River (RM 98) upstream to Deadman Creek
(RM 186.5) (Figure 1).
FINAL REPORT THERMAL INFRARED REMOTE SENSING PILOT TEST STUDY
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 2 February 2013
4. METHODS
4.1. Instrumentation
WSI (Watershed Sciences, Inc.) was contracted to collect airborne TIR imagery over a 4-day
period in October 2012. To maximize thermal contrast between warmer groundwater discharge
and colder river temperatures of the Susitna, the TIR sensor was flown during early morning
when solar loading was minimized. Collected stream sections and extents are listed in Table 1.
Images were collected with a FLIR system’s SC6000 sensor (8–9.2 micrometer [µm]) mounted
on the underside of a Bell Jet Ranger Helicopter. The SC6000 is a calibrated radiometer with
internal non-uniformity correction and drift compensation. The sensor is contained in a
composite fiber enclosure attached to the underside of the helicopter which is flown
longitudinally along the stream channel. General specifications of the thermal infrared sensor are
listed in Table 2, and a picture of the apparatus is shown on Figure 2.
4.2. Image Collection
Due to the river’s width, the aircraft was flown in parallel flight lines in order to capture the full
floodplain extent of the Susitna River. The flight lines were designed for an image side-lap of 40
percent and the TIR sensor was set to acquire images at a rate of 1 image every second resulting
in an image overlap of approximately 65 percent. Narrower locations upstream were collected
with a single flight pass.
The TIR data acquisition was conducted at a flight altitude of 2,300 feet above ground level
(AGL) resulting in pixel resolution of 2.3 feet (ft; 0.70 meter [m]). Due to terrain variations,
wind conditions, and stream size, altitudes can vary throughout the flight duration. A summary
of flight times and acquisition parameters can be seen in Table 3.
Thermal infrared images were recorded directly from the sensor to an on-board computer as raw
counts which were then converted to radiant temperatures. The individual images were
referenced with time, position, and heading information provided by a global positioning system
(GPS) (Figure 3).
4.3. Ground Control
Six in-stream sensors in the mainstem Susitna were used for calibrating and verifying the thermal
accuracy of the TIR imagery. Data for other sensor locations in the River were either not
available for the dates of the surveys or were in areas of increased thermal mixing and could not
be used for calibration purposes. Data logger locations are illustrated in Figure 4.
4.4. Weather and Flow
Weather conditions on the mornings of the survey were considered ideal for detecting
groundwater inflows to the Susitna River with cold temperatures, low humidity and clear skies.
Table 4 summarizes the weather conditions observed in Talkeetna, Alaska (Station ID: CYFC)
on the survey dates. No flights were conducted on October 14-16, 2012 due to warmer
temperatures and low clouds in the area.
FINAL REPORT THERMAL INFRARED REMOTE SENSING PILOT TEST STUDY
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 3 February 2013
4.5. Surface Temperatures
Thermal infrared sensors measure TIR energy emitted at the water’s surface. Since water is
essentially opaque to TIR wavelengths, the sensor is only measuring water surface temperatures.
Thermal infrared data accurately represents bulk water temperatures where the water column is
thoroughly mixed; however, temperature differences can form in the vertical water column in
areas that have little or no mixing. Given the cold temperatures, it is possible that ice was present
in areas of the survey.
4.6. Expected Accuracy
Thermal infrared radiation received at the sensor is a combination of energy emitted from the
water’s surface, reflected from the water’s surface, and absorbed and re-radiated by the
intervening atmosphere. Water is a good emitter of TIR radiation and has relatively low
reflectivity (~ 4 to 6 percent). In general, apparent stream temperature changes of < 0.5°C are
not considered significant unless associated with a surface inflow (e.g., tributary). However,
certain conditions may cause variations in the accuracy of the imagery.
4.7. Surface Conditions
Variable water surface conditions (i.e., riffle versus pool), slight changes in viewing aspect, and
variable background temperatures (i.e., sky versus trees) can result in differences in the
calculated radiant temperatures within the same image or between consecutive images. The
apparent temperature variability is generally less than 0.5°C (Torgersen et al. 2001). The
occurrence of reflections as an artifact (or noise) in the TIR images is a consideration during
image interpretation and analysis.
4.8. Feature Size and Resolution
A small stream width logically translates to fewer pure stream pixels and greater integration with
non-water features such as rocks and vegetation. Consequently, a narrow channel (relative to the
pixel size) can result in higher variability and inaccuracies in the measured radiant temperatures
as more ‘mixed pixels’ are sampled. This is a consideration especially when sampling the radiant
temperatures at tributary mouths and surface springs.
4.9. Image Uniformity
The TIR sensor used for this study uses a focal plane array of detectors to sample incoming
radiation. A challenge when using this technology is to achieve uniformity across the detector
array. The sensor has a correction scheme which reduces non-uniformity across the image frame;
however, differences in temperature (typically <0.5°C) can be observed near the edge of the
image frame. The uniformity differences within frames and slight differences from frame-to-
frame are most apparent in the continuous mosaics.
FINAL REPORT THERMAL INFRARED REMOTE SENSING PILOT TEST STUDY
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 4 February 2013
4.10. Temperatures and Color Ramps
The TIR images collected during this survey consist of a single band. As a result, visual
representation of the imagery (in a report or geographic information system [GIS] environment)
requires the application of a color ramp or legend to the pixel values. The selection of a color
ramp should highlight features most relevant to the analysis (i.e., spatial variability of stream
temperatures). For example, a continuous, gradient style color ramp that incorporates all
temperatures in the image frame will provide a smoother transition in colors throughout the
entire image, but will not highlight temperature differences in the stream. Conversely, a color
ramp that focuses too narrowly cannot be applied to the entire river and will wash out terrestrial
and vegetation features (Figure 5).
The color ramps for the TIR mosaics were developed to maximize the contrast of the majority of
the surface water features and are unique by date. The color ramp can be modified by the end
user to highlight features or temperature ranges of interest.
4.11. Sensor Calibration
The response characteristics of the TIR sensor are measured in a laboratory environment. The
response curves relate the raw digital numbers recorded by the sensor to emitted radiance from a
black body. The raw TIR images collected during the survey initially contain digital numbers,
which are then converted to radiance temperatures based on the factory calibration.
The calculated radiant temperatures are adjusted based on the kinetic temperatures recorded at
each ground truth location. This adjustment is performed to correct for path length attenuation
and the emissivity of natural water. The in-stream data are assessed at the time the image is
acquired, with radiant values representing the median of ten points sampled from the image at
the data logger location.
4.12. Geo-referencing
During the survey, the images are tagged with a GPS position and heading at the time they are
acquired. Since the TIR camera is maintained at vertical down-look angles, the geographic
coordinates provide a reasonably accurate index to the location of the image scene. However,
due to the relatively small footprint of the imagery and independently stabilized mount, image
pixels are not individually registered to real world coordinates. The image index is saved as an
ESRI point shapefile containing the image name registered to an X and Y position of the sensor
and the time of capture.
4.13. Geo-rectification
Due to the complexity and width of the river, both manual and automated rectification
techniques were used to process the imagery. All imagery was rectified to the high resolution
true-color imagery. In narrower portions of the river, individual TIR frames were manually geo-
rectified by finding a minimum of six common ground control points (GCPs) between the image
frames and imagery available for the area. The images were then warped using a first order
polynomial transformation and mosaicked into a final image. All TIR imagery collected on
October 17 and 18, 2012, was manually rectified.
FINAL REPORT THERMAL INFRARED REMOTE SENSING PILOT TEST STUDY
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 5 February 2013
The wider areas of river flown on October 12 and 13 were rectified using automated techniques
due to the multiple flight lines which needed to be tied together. Trajectory and GPS data for the
entire flight survey session were incorporated into an External Orientation (EO) file that contains
accurate and continuous aircraft positions and heading. Ground control points were created by
identifying permanent structures (boulders, high contrast landform shapes, and edges of man-
made structures) in the true color orthoimagery that were also easily discernible in the TIR
imagery. The coordinates for these points (x,y,z) are recorded from a 10-meter bare earth Digital
Elevation Model obtained from the NRCS’s National Elevation Dataset and used to rectify the
imagery. The ground control points and EO file are loaded into Leica Photogrammetry Suite,
which aerial triangulates the thermal images and ties them together. Images are then output into
orthorectified mosaics using OrthoVista software. No adjustments were made to cell values so
temperature information was preserved.
4.14. Interpretation and Sampling
Once calibrated and rectified, the images are integrated into a GIS in which an analyst interprets
and samples stream temperatures. The Susitna thermal mosaics were qualitatively inspected for
groundwater presence or absence based on water temperatures. A polygon shapefile was
digitized to highlight areas of increased groundwater activity. In general terms, the bulk water
river temperatures were colder than the emergent groundwater, making subsurface activity easily
detectable. Because temperatures exist on a continuum, the polygons should not be used to
quantitatively define groundwater flows.
4.15. Temperature Profiles
In order to provide further thermal interpretation, the median bulk water temperature for the river
was sampled at 500-foot intervals and plotted versus river mile to develop a longitudinal
temperature profile. The profile illustrates how stream temperatures vary spatially along the
stream gradient and highlights any landscape scale trends. The locations of named surface water
inflows (e.g., tributaries, surface springs, etc.) are included on the plot to illustrate how these
inflows influence the mainstem temperature patterns.
The profile was created directly from the TIR image mosaic using the following steps:
1. A stream line was digitized and routed based on the final thermal mosaics to best
represent the centerline of the channel.
2. A GIS point layer was generated from the routed stream layer at 500-foot intervals and
each point was assigned the appropriate river mile measure. Mapped river miles were
adjusted to closely match URS in-stream sensor river miles.
3. The points were buffered by 25 feet to create polygons within the stream center. For
points which fell on non-water features or were obvious errors due to image mosaic
artifacts were discarded.
4. The Zonal Statistics feature of ArcGIS was then used to calculate the median radiant
temperature and associated statistics contained in each polygon from the TIR image
mosaic.
FINAL REPORT THERMAL INFRARED REMOTE SENSING PILOT TEST STUDY
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 6 February 2013
5. The median radiant temperatures were then assigned back to the center point and the
temperatures were plotted in Microsoft Excel versus river mile.
6. A similar process was followed for larger tributaries and sloughs. However, rather than
automated spacing of points based on the centerline, points were hand placed at the
mouths of the tributaries or in wider areas of sloughs and assigned a river mile. Due to
the smaller size of the features, tributary and slough points were only buffered by 10 feet
for sampling. The tributary analysis was not meant to be comprehensive, but to act as
further reference for the longitudinal profile and to highlight significant features.
As mentioned, data from six mainstem sensors were used to calibrate the thermal imagery
(Figure 4). Table 5 summarizes a comparison between the kinetic temperatures recorded by the
in-stream data loggers and the radiant temperatures derived from the TIR images. Due to the
multiple flight lines in the lower portion of the river, the same sensor may be cross-checked
across multiple images.
The differences between radiant and kinetic temperatures were consistent with other airborne
TIR surveys previously conducted at other sites, and within the target accuracy of ±0.5°C;
however, there were some discrepancies seen between the in-stream sensors that were not used
and the calibrated radiant temperatures of October 17.
The studies only used sensors that were in the mainstem Susitna and not in areas of potential
mixing to evaluate bulk temperatures. Three sensors had data available on October 17 but were
not used in the accuracy assessment:
At RM 140.0 the in-stream sensor recorded a temperature of -3.63°C, which was
considered suspect.
A second sensor downstream of Portage Creek (RM 148) was located in an area of
mixing, which also caused a discrepancy between in-stream and radiant values.
The sensor at RM 142.0 (Slough 21) was in an area of apparent groundwater discharge
and therefore reading higher than bulk water temperatures.
The sensor upstream of Portage Creek (RM 148) did not have available data for October.
No in-stream sensor data were available for the imagery flown on October 18 so the calibration
focused on matching bulk water temperatures with the calibration on October 17. Given the
conditions at the time of the survey and the lack of sensors to confirm in-stream temperatures,
water temperatures in the thermal imagery are below freezing. The calculation of negative
temperatures is based on the calibration of the lower sensors and the calculation of parameters to
match the October 17 imagery. We opted to retain the areas of negative temperatures in order to
maintain consistency in the calibration and the relative temperatures along the stream gradient.
Due to the lack of available in-stream sensor data for the upstream portion of the 17th and full
extent of the 18th, temperatures seen in those extents should not be considered absolute;
however, upwelling activity can still be confirmed due to the contrast between groundwater
temperatures and bulk river temperatures.
FINAL REPORT THERMAL INFRARED REMOTE SENSING PILOT TEST STUDY
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 7 February 2013
5. DEVIATIONS FROM STUDY PLAN
There were some adjustments that had to be made using the aerial photos and temperature
confirmation sensors in the river; however, these types of adjustments are not atypical for this
type of work, and were anticipated as part of the study. The initial conception of the study was
to survey a smaller area of the river, from approximately Talkeetna to Devils Canyon. However,
during initiation of the study, it was determined that the additional cost to survey the river
between Devils Canyon and the proposed dam site was relatively small, and the environmental
conditions at the time were ideal for surveying.
6. RESULTS
The results of this study are available in Appendix 1 (Examples in Figures 5 and 6). Due to the
nature of the study, the focus of the survey was to highlight groundwater sources that were
warmer than bulk water temperatures on a cold winter morning. The cold air temperatures act to
suppress mainstem and terrestrial temperatures and allow the warmer groundwater to stand out in
the imagery. Over 500 areas of increased groundwater activity were seen in the thermal imagery
from large sloughs to small hyporheic seeps (Figure 7). The bulk of the groundwater activity
(>90 percent) was seen between the Chulitna River and Slough 21 (RM 98-143).
Median channel temperatures were also plotted versus river mile for the Susitna River.
Significant tributaries and sloughs sampled during the analysis are included on the longitudinal
profiles to provide additional context for interpreting spatial temperature patterns (Figure 8).
While the groundwater could be easily discerned in the imagery, the longitudinal temperature
profile of the mainstem of the river is less informative in this type of winter survey due to the
minimal fluctuations in bulk water temperatures. Apparent stream temperature changes of
< 0.5°C (0.5 K) are not considered significant unless associated with a surface inflow (e.g.,
tributary).
The prevalence of groundwater downstream of RM 140 does appear to impact bulk water
temperatures by increasing the overall temperature. The upward slope seen in the profile,
particularly between Deadhorse Creek (RM 121) and Lane Creek (RM 113.5), is a reflection of
this increase in temperatures. Temperatures increase almost 1°C (1.0 ºK) along this length of
river.
Though it is not obvious in the longitudinal profile, Lane Creek (RM 113.5), Lower Portage
Creek at RM 117.6, and the Indian River (RM 138.6) are all contributing significantly warmer
water to the mainstem (Figure 9). Ten sloughs of significant size and thermal influence were also
noted in the imagery including Slough 8A (RM 126.0), Slough 9 (129.2), and Slough 21 (RM
142.0).
With air temperatures in the teens on October 18, parts of the river appeared to be freezing over,
likely causing the increase in variability seen in the temperature profile on that date. The imagery
also reflects the colder temperatures and the ‘colder’ color ramp that was necessary for the upper
section of the river (Figure 10).
FINAL REPORT THERMAL INFRARED REMOTE SENSING PILOT TEST STUDY
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 8 February 2013
7. DISCUSSION
Thermal infrared imagery was collected for the Susitna River over a 4-day period in October of
2012. Given the difficult conditions involved in surveying the Susitna and the limited window of
weather conditions that will allow for groundwater detection in this type of glacial river, the
survey was highly successful. Hundreds of areas of groundwater activity were detected in the
imagery, from large sloughs to small hyporheic seeps. Based on the results of this study, the pilot
test appears to have been a complete success. Based on the success of this study, AEA plans to
replicate this work in the Lower River Segment in 2013.
8. REFERENCES
AEA (Alaska Energy Authority). 2012. Revised Study Plan: Susitna-Watana Hydroelectric
Project FERC Project No. 14241. December 2012. Prepared for the Federal Energy
Regulatory Commission by the Alaska Energy Authority, Anchorage, Alaska.
http://www.susitna-watanahydro.org/study-plan.
Torgersen, C.E., R. Faux, B.A. McIntosh, N. Poage, and D.J. Norton. 2001. Airborne thermal
remote sensing for water temperature assessment in rivers and streams. Remote Sensing
of Environment 76(3): 386-398.
FINAL REPORT THERMAL INFRARED REMOTE SENSING PILOT TEST STUDY
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9 February 2013
9. TABLES
Table 1. Surveyed Stream Lengths and Acquisition Dates
Survey Date Approximate River Miles Flown
10/12/2012 9
10/13/2012 23
10/17/2012 37
10/18/2012 19
Total: 88
Table 2. Summary of TIR Sensor Specifications
FLIR System SC6000 (LWIR)
Wavelength: 8-9.2 m
Noise Equivalent Temperature Differences (NETD): 0.035°C
Pixel Array: 640 (H) x 512 (V)
Encoding Level: 14 bit
Horizontal Field-of-View: 35.5°
Table 3. Summary of Thermal Image Acquisition Parameters
Acquisition Parameters
Dates: October 12,13,17,18, 2012
Flight Above Ground Level (AGL): 2,300 feet
Image Footprint Width: 1,472 feet (449 meters)
Pixel Resolution: 2.3 feet (0.7 meters)
FINAL REPORT THERMAL INFRARED REMOTE SENSING PILOT TEST STUDY
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 10 February 2013
Table 4. Weather Conditions on the Survey Dates in Talkeetna, Alaska
Time (ADT) Air Temp. (°C) Humidity Wind Direction Wind Speed Conditions
12-October-2012
5:53 AM 30.0°F 51% Calm Calm Clear
6:53 AM 27.0°F 61% Calm Calm Clear
7:53 AM 28.0°F 56% North 5.8 mph Clear
9:53 AM 30.0°F 49% North 4.6 mph Clear
10:53 AM 33.1°F 46% North 4.6 mph Clear
13-October-2012
5:53 AM 28.9 °F 47% North 4.6 mph Clear
6:53 AM 28.9 °F 47% North 4.6 mph Clear
7:53 AM 28.9 °F 45% North 4.6 mph Clear
8:53 AM 28.0 °F 47% Calm Calm Clear
9:53 AM 27.0 °F 53% North 4.6 mph Clear
17-October-2012
5:53 AM 26.1 °F 92% Calm Calm Clear
6:53 AM 21.9 °F 96% Calm Calm Clear
7:53 AM 19.9 °F 100% Calm Calm Clear
8:53 AM 19.0 °F 92% Calm Calm Clear
9:53 AM 21.0 °F 92% Calm Calm Partly Cloudy
18-October-2012
5:53 AM 14.0 °F 88% Calm Calm Clear
6:53 AM 14.0 °F 88% Calm Calm Clear
7:53 AM 15.1 °F 84% NNW 3.5 mph Clear
8:53 AM 16.0 °F 88% Calm Calm Clear
9:53 AM 23.0 °F 68% NNW 5.8 mph Clear
FINAL REPORT THERMAL INFRARED REMOTE SENSING PILOT TEST STUDY
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 11 February 2013
Table 5. Comparison of radiant temperatures derived from the TIR images and
kinetic temperatures from the in-stream sensors
River
Mile
Sensor ID Image Frame Time In-stream
Temp (°C) Radiant (°C) Difference
Figure 1. October 12, 2012
103.3 103.3_Talkeetna Susitna1076 8:38:59 1.26 1.3 -0.01
103.3 103.3_Talkeetna Susitna0957 8:34:23 1.26 1.1 0.16
Figure 2. October 13, 2012
126.1 1014217_1-_Oct-126.1 Susitna2705 9:41:24 0.08 0.3 -0.22
126.1 1014217_1-_Oct-126.1 Susitna2560 9:35:06 0.08 0.3 -0.22
130.8
10174222_1-_Oct-Oct-130.8-
LRX35 Susitna2239 9:22:15 0.11 0.4 -0.29
130.8
10174222_1-_Oct-Oct-130.8-
LRX35 Susitna2822 9:45:18 0.11 0.3 -0.19
103.8
10174222_1-_Oct-Oct-130.8-
LRX35 Susitna0032 7:33:16 0.10 1.0 -0.90
Figure 3. October 17, 2012
130.8 10174222_1-Oct-130.8-LRX35 Susitna0156 8:05:57 0.16 -0.3 0.46
136.5 10174295_0-Oct_136.5-Susitna
Near Gold Creek
Susitna0567 8:26:21 0.14 0.2 -0.07
138.7 10174225-_Oct-138.7-Susitna
Above Indian River
Susitna0973 8:45:06 0.02 -0.2 0.22
140.1 1014282_Oct-140.1-LRX 53 Susitna0950 8:44:14 0.14 -0.1 0.24
Figure 4. October 18, 2012
Although there were mapped sensor locations above this point, no actual sensor data was available for this date. Calibration focused on
matching bulk water temperatures to the prior days’ temperatures. While the relative temperatures of the survey are still considered accurate
and highlight groundwater activity, pixel values should not be considered absolute.
FINAL REPORT THERMAL INFRARED REMOTE SENSING PILOT TEST STUDY
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 12 February 2013
Table 6. Summary of Information Provided in Appendix A
Projection: Alaska State Plane Zone 4 FIPS 5004
Horizontal Datum: NAD83
Units: Feet
Rasters
Thermal Mosaics (ERDAS Imagine)
Continuous mosaics of rectified TIR image frames. Layer files included
for display by temperature class.
Cell Values = Kelvin*10
Vectors
Groundwater Activity (ESRI polygon shapefile)
Sampled TIR centerline points (ESRI point shapefile)
Sampled TIR inflow points (ESRI point shapefile)
Flightline image locations (ESRI point shapefiles)
Hydrography
Routed stream centerline based on TIR image mosaics
NHD stream network (ESRI Geodatabase)
Spreadsheets Longitudinal temperature profile (Microsoft Excel)
Analysis ArcMap 10.0 project (*.mxd)
Thermal hydrologic analysis (PDF Report)
FINAL REPORT THERMAL INFRARED REMOTE SENSING PILOT TEST STUDY
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 13 February 2013
10. FIGURES
Figure 1. Susitna River sections surveyed in October 2012.
FINAL REPORT THERMAL INFRARED REMOTE SENSING PILOT TEST STUDY
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 16 February 2013
Figure 2. Bell Jet Ranger equipped with mounted FLIR sensor.
Figure 3. Thermal image locations.
Each location is represented by a yellow dot. The inset box shows the information recorded with
each image during acquisition.
FINAL REPORT MERCURY STUDY
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 17 February 2013
Figure 4. Location of temperature sensors used for calibration.
FINAL REPORT MERCURY STUDY
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 18 February 2013
Figure 5. Examples of different color ramps applied to the same TIR image.
Figure 6. Example of Appendix A map.
FINAL REPORT MERCURY STUDY
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 19 February 2013
Figure 7. TIR/True Color Image Comparison.
The TIR/true color image pair above shows an example of the small hyporheic seeps that were
detected in the thermal imagery, particularly in the exposed gravel beds.
FINAL REPORT MERCURY STUDY
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 20 February 2013
Figure 8. Longitudinal temperature profile for the Susitna River and sampled inflows.
Select named tributaries are shown for reference.
FINAL REPORT MERCURY STUDY
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 21 February 2013
Figure 9. The TIR images of three significant tributaries to the Susitna River.
While the majority of tributaries were either frozen or at the same temperature as the mainstem,
Lane Creek (RM 113.5), Portage Creek (lower) (RM 117.6), and Indian River (RM 138.6) were
all contributing warmer water to the mainstem. Note there is more than one tributary named
“Portage Creek” on the Susitna River. This map refers to the lower Portage Creek, near
Talkeetna.
FINAL REPORT MERCURY STUDY
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 22 February 2013
Figure 10. Junction between acquisition days October 17 and 18, 2012.
Air temperatures were colder on October 18, 2012, which affects the display of the terrestrial
features in the imagery. Bulk water temperatures were significantly colder on October 17 and 18,
2012 when compared to October 12 and 13, 2012, requiring a color ramp that displayed water
temperatures below freezing.
FINAL REPORT THERMAL INFRARED REMOTE SENSING PILOT TEST STUDY
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Appendix A February 2013
Appendix A – TIR Field Data