Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Watana Hydro project watershed historical hydrology 2011
Alaska Resources Library & Information Services Susitna-Watana Hydroelectric Project Document ARLIS Uniform Cover Page Title: Watana Hydroelectric Project, Susitna watershed historical hydrology SuWa 114 Author(s) – Personal: Author(s) – Corporate: MWH [i.e. MWH Americas Inc.] AEA-identified category, if specified: Briefing and Technical Documents AEA-identified series, if specified: Technical memorandum ; no. 3 (NTP 3) Series (ARLIS-assigned report number): Susitna-Watana Hydroelectric Project document number 114 Existing numbers on document: AEA11-022 TM-03-003-052411v1.0 Published by: [Anchorage, Alaska : Alaska Energy Authority, 2011] Date published: June 1, 2011 Published for: Prepared for Alaska Energy Authority Date or date range of report: Volume and/or Part numbers: Final or Draft status, as indicated: Document type: Technical memorandum Pagination: 41, [1] p. Related work(s): Pages added/changed by ARLIS: Notes: All reports in the Susitna-Watana Hydroelectric Project Document series include an ARLIS- produced cover page and an ARLIS-assigned number for uniformity and citability. All reports are posted online at http://www.arlis.org/resources/susitna-watana/ NTP 3 Technical Memorandum No. 3 Watana Hydroelectric Project Susitna Watershed Historical Hydrology Alaska Railbelt Large Hydro Engineering Services AEA11-022 Prepared for: Prepared by: Alaska Energy Authority MWH 813 West Northern Lights Blvd. 2353 130 th Avenue NE, Suite 200 Anchorage, AK 99503 Bellevue, WA 98005 June 1, 2011 TM-03-003-052411v1.0 ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 1 of 41 06/01/2011 Table of Contents I. Hydrologic Record ..................................................................................................................... 2 II. Monthly Flow Summary ............................................................................................................. 4 III. Monthly Flow Frequency and Flow Duration ............................................................................ 15 IV. Watana Dam Site Historical Flows ........................................................................................... 26 V. Flood Frequency...................................................................................................................... 31 VI. Susitna Watershed Flow Distribution ....................................................................................... 40 VII. References .............................................................................................................................. 41 ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 2 of 41 06/01/2011 W ATANA H YDROELECTRIC PROJECT – SUSITNA W ATERSHED HISTORICAL H YDROLOGY The purpose of this technical memorandum is to summarize existing hydrologic data in the Susitna River watershed, and to present statistics for estimated flow at the Watana dam site. Sections of this memorandum include (1) hydrologic record; (2) monthly flow summary; (3) monthly flow frequency and flow distribution; (4) Watana dam site historical flows; (5) flood frequency; and (6) Susitna watershed flow distribution. Hydrologic change will be covered in a separate technical memorandum. Results presented herein are preliminary. I. Hydrologic Record A summary of recorded flow data in the Susitna River watershed is useful to many groups associated with the Watana Hydroelectric Project. Recorded flow data is also needed to develop a long-term estimate of flow and flood frequency at the Watana dam site for use in Project design, reservoir operation and power generation studies. Fourteen gaging stations have been intermittently operated by the USGS within the Susitna River watershed between 1949 and 2011 (Table 1). An additional station on the Little Susitna River, which is not a tributary of the Susitna River, was included in Table 1 due to its proximity to the Susitna River and the exceptionally long period of record for this gage. Table 1: USGS Streamflow Gages in the Susitna Watershed USGS Gage Number Gage Name Drainage Area (sq.mi.) Latitude Longitude Gage Datum (feet) Available Period of Record 15290000 Little Susitna River near Palmer 62 61°42'37"149°13'47" 917 63 years: 1948 - 2011 15291000 Susitna River near Denali 950 63°06'14" 147°30'57" 2,440 27 years: 1957 - 1976; 1978 - 1986 15291200 Maclaren River near Paxson 280 63°07'10" 146°31'45" 2,866 28 years: 1958 - 1986 15291500 Susitna River near Cantwell 4,140 62°41'55"147o32'42"1,900 17 years: 1961 - 1972; 1980 - 1986 15292000 Susitna River at Gold Creek 6,160 62o46'04" 149 o41'28"677 57 years: 1949 - 1996; 2001 - 2011 15292400 Chulitna River near Talkeetna 2,570 62°33'31"150°14'02" 520 20 years: 1958 - 1972; 1980 - 1986 15292700 Talkeetna River near Talkeetna 1,996 62°20'49" 150°01'01" 400 47 years: 1964 - 2011 15292780 Susitna River at Sunshine 11,100 62o10'42" 150 o10'30"270 5 years: 1981 - 1986 15292800 Montana Creek near Montana 164 62°06'19" 150°03'27" 250 4 years: 2005 - 2006; 2008 - 2011 15294005 Willow Creek Near Willow 166 61°46'51" 149°53'04" 350 25 years: 1978 - 1993; 2001 - 2011 15294010 Deception Creek near Willow 48 61°44'52" 149°56'14" 250 7 years: 1978 - 1985 15294100 Deshka River near Willow 591 61°46'05" 150°20'13" 80 11 years: 1978 - 1986; 1998 - 2001 15294300 Skwentna River near Skwentna 2,250 61°52'23" 151°22'01" 200 23 years: 1959 - 1982 15294345 Yentna River near Susitna Station 6,180 61°41'55" 150°39'02 80 6 years: 1980 - 1986 15294350 Susitna River at Susitna Station 19,400 61°32'41" 150°30'45 40 19 years: 1974 - 1993 ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 3 of 41 06/01/2011 The locations of the gaging stations listed in Table 1, along with the watershed boundaries for the entire Susitna River and the portion of the River tributary to the Watana dam site, are shown in Exhibit 1, Susitna River Drainage Basin Boundary and Streamflow Gages Location map. Figure 1 shows the chronological availability of USGS flow data in the Susitna watershed. A modeled daily flow data set for the Watana dam site was developed from the daily data at the downstream gage at Gold Creek and the upstream gage near Cantwell. The drainage area at the Watana dam site, 5,180 square miles, is approximately half way between the drainage area at Cantwell (4,140 square miles) and Gold Creek (6,160 square miles). The drainage areas for these sites were confirmed with GIS measurements. The 17 years of concurrent data at the Cantwell and Gold Creek gaging stations were used to calculate monthly scaling factors for use in estimating flows at Watana, as described below. Figure 1 also shows an active period of flow gaging in the early 1980s, with at least four years of concurrent data at almost all sites. Figure 1: Susitna Watershed USGS Flow Data – Chronological Availability Other useful gaging stations for describing flow in the watershed are located on the Susitna River at Sunshine and at Susitna Station, and on the Chulitna River near Talkeetna. This memo presents detailed summaries (flow duration, flow frequency, flood frequency) for data at these four sites in addition to Cantwell and Gold Creek. Flow data for the remaining 10 sites is summarized with average monthly flow data tables. Station Name (USGS Station Number)1948194919501951195219531954195519561957195819591960196119621963196419651966196719681969197019711972197319741975197619771978197919801981198219831984198519861987198819891990199119921993199419951996199719981999200020012002200320042005200620072008200920102011Note: Data are on a calendar year basis. Legend Complete years of record Partial years of record Montana Creek near Montana (15292800) Susitna River at Sunshine (15292780) Talkeetna River near Talkeetna (15292700) Susitna River at Susitna Station (15294350) Yentna River near Susitna Station (15294345) Skwentna River (15294300) Deshka River near Willow (15294100) Deception Creek near Willow (15294010) Willow Creek Near Willow (15294005) Chulitna River near Talkeetna (15292400) Susitna River at Gold Creek (15292000) Susitna River near Cantwell (15291500) Susitna River near Denali (15291000) Little Susitna River near Palmer (15290000) Maclaren River near Paxson (15291200) ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 4 of 41 06/01/2011 Within the period of record for gages in the Susitna watershed, there have been several periods of no gage-height record, some lasting for several consecutive months. The USGS has developed estimated flows for the period of no gage-height records, as is their customary practice, to provide a continuous period of record during operational years. All of the data used in hydrologic analyses for the Susitna watershed are accepted measured or estimated values published by the USGS. II. Monthly Flow Summary Average monthly flows over the period of record for the gage sites listed in Table 1 are presented below (Table 2). As shown in Table 1 and in Figure 2, flow in the Susitna River and its tributaries is highly seasonal, with peak flows in July corresponding with summer snow melt conditions, and low winter flows occurring when much precipitation is stored in the watershed as snow. Tables 3 through 17 below present the average monthly flows on an annual basis for the period of record at the USGS gaging stations listed in Table 1. Table 2: Average Monthly Flows (cfs) at USGS Gages in the Susitna Watershed Little Susitna River near Palmer Susitna River near Denali Maclaren River near Paxson Susitna River near Cantwell Susitna River at Gold Creek Chulitna River near Talkeetna Talkeetna River near Talkeetna Susitna River at Sunshine Montana Creek near Montana Willow Creek near Willow Deception Creek near Willow Deshka River near Willow Skwentna River near Skwentna Yentna River near Susitna Station Susitna River at Susitna Station (61.9mi2) (950mi 2) (280mi 2) (4,140mi 2) (6,160mi 2) (2,570mi 2) (1,996mi 2) (11,100mi 2) (164.1mi 2) (166mi 2) (48mi 2) (591mi 2) (2,250mi 2) (6,180mi 2) (19,400mi 2) January 31 262 105 961 1,590 1,367 666 4,375 39 84 18 277 1,120 3 ,265 8,487 February 25 220 90 828 1,414 1,132 562 3,939 33 73 15 239 953 2,9 85 7,739 March 21 199 82 779 1,297 1,001 508 3,496 31 61 15 240 837 2,576 7 ,136 April 27 233 89 915 1,753 1,171 703 3,948 54 95 39 590 1,095 3,863 10,021 May 240 2,135 850 7,908 14,138 8,169 5,050 27,970 888 653 169 2,800 8,599 26,433 64,825 June 661 7,279 2,894 18,230 26,417 21,474 10,631 56,472 547 981 95 902 19,001 47,997 118,479 July 485 9,831 3,240 17,542 23,871 26,363 10,151 66,238 346 637 89 831 17,644 53,394 130,317 August 409 8,159 2,548 14,918 21,365 22,516 9,102 60,972 576 619 84 1,140 13,401 49,070 113,051 September 306 3,296 1,136 7,936 13,741 11,834 5,860 35,202 5 41 633 91 1,231 8,466 27,608 74,446 October 148 1,181 421 3,365 6,345 5,188 2,946 16,600 246 427 72 1,161 4,522 14,003 39,578 November 64 525 192 1,575 2,679 2,169 1,201 6,787 70 158 47 673 1,945 5,823 15,966 December 41 339 130 1,117 1,892 1,576 820 4,877 47 105 25 338 1,327 3,893 9,983 Annual 206 2,793 981 6,340 9,805 8,792 4,039 23,864 242 388 65 903 6,640 20,208 50,417 Gage Location (drainage area) ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 5 of 41 06/01/2011 Figure 2: Average Monthly Flows in the Susitna Watershed 0 20,000 40,000 60,000 80,000 100,000 120,000 140,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov DecMonthly Average Flow (cfs)Little Susitna near Palmer Susitna near Denali Maclaren River near Paxson Susitna River near Cantwell Susitna River at Gold Creek Chulitna River near Talkeetna Talkeetna River near Talkeetna Susitna River at Sunshine Montana Creek near Montana Willow Creek near Willow Deception Creek near Willow Deshka River near Willow Skwentna River near Skwentna Yentna River at Susitna Station Susitna River at Susitna Station Based on Historic Recorded Daily Flows in theSusitna River Watershed ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 6 of 41 06/01/2011 Table 3: Average Flows (cfs) at USGS Gage 15290000 - Little Susitna River near Palmer Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Annual 1948 --- --- --- --- --- --- 557.9 661.2 280.0 136.7 60.0 43.9 --- 1949 30.9 21.7 20.4 23.5 314.7 1,176.0 940.3 680.6 321.4 134.5 50.8 30.8 313.6 1950 25.0 16.6 17.8 17.8 57.4 519.1 358.1 296.4 154.0 67.9 35.0 31.0 133.4 1951 27.0 21.0 16.5 22.1 214.0 708.5 488.7 445.9 543.5 138.6 50.3 36.0 226.5 1952 23.1 14.0 13.0 15.0 151.6 966.5 697.4 427.9 386.9 133.8 80.4 38.5 246.3 1953 31.0 20.7 16.0 22.3 267.9 642.2 278.0 443.6 245.7 83.0 47.0 31.0 178.0 1954 21.0 16.0 13.0 18.0 202.1 297.5 381.4 499.5 298.2 126.7 56.2 17.4 163.4 1955 19.6 15.9 11.3 10.0 88.4 665.6 805.9 556.3 279.8 85.2 37.7 27.0 218.2 1956 20.0 16.0 10.0 17.0 129.3 576.9 609.6 398.4 304.6 86.6 56.3 32.9 189.0 1957 24.1 19.4 10.5 17.7 348.2 701.9 309.9 217.6 539.6 170.5 81.4 43.1 207.1 1958 24.4 20.7 14.5 20.0 157.7 398.4 240.4 304.7 125.3 111.4 44.5 31.9 125.1 1959 17.5 15.5 14.5 16.5 212.0 797.4 458.9 735.7 305.2 111.1 54.0 30.9 231.9 1960 29.5 19.6 13.0 19.1 381.6 398.1 367.3 361.5 351.2 129.1 60.7 44.1 182.3 1961 54.1 25.0 17.5 20.5 185.5 605.5 505.9 456.4 348.4 156.3 65.2 33.1 207.0 1962 36.4 27.4 24.8 25.6 141.7 994.2 568.5 533.6 345.0 98.7 47.9 37.3 240.6 1963 33.2 24.7 22.3 23.9 319.5 857.9 1,047.0 825.3 201.7 167.8 59.6 38.1 304.2 1964 27.4 22.9 19.8 24.5 72.2 932.1 456.0 294.1 178.2 122.9 62.5 41.9 188.0 1965 31.0 26.3 25.6 34.1 121.4 481.6 496.7 450.9 606.1 180.7 70.3 47.4 215.0 1966 30.5 25.1 21.0 23.0 83.5 546.2 361.0 401.9 223.3 109.6 69.2 42.5 161.9 1967 27.3 23.1 21.4 23.2 247.6 789.9 632.8 524.0 311.7 88.3 46.5 33.3 231.8 1968 29.8 29.0 27.6 26.7 374.2 919.9 600.7 231.4 115.2 51.3 24.5 19.8 204.9 1969 24.0 22.5 18.1 21.9 178.9 289.1 241.9 169.3 82.2 76.3 45.9 33.0 100.8 1970 25.9 20.4 19.7 19.7 194.5 405.8 418.9 422.1 199.2 117.9 71.6 43.0 164.3 1971 30.5 24.5 18.2 18.3 52.9 675.4 622.3 908.5 177.3 92.3 63.9 35.2 228.2 1972 31.2 25.9 19.6 18.0 117.1 883.9 743.4 297.4 408.7 209.5 80.2 44.2 240.5 1973 31.6 27.7 25.0 24.0 157.3 671.1 373.7 392.1 164.9 90.4 50.8 36.3 171.0 1974 32.4 27.7 19.8 21.0 395.5 643.0 407.2 258.7 177.6 96.2 56.3 36.1 181.7 1975 30.0 25.8 21.4 20.8 134.6 731.1 720.4 347.7 521.8 156.6 65.7 44.9 235.7 1976 28.1 23.8 18.7 20.5 121.8 708.8 426.8 215.8 102.9 76.2 51.5 44.5 153.6 1977 31.1 25.6 22.0 25.4 179.6 1,215.0 619.3 246.5 465.0 183.4 61.5 48.1 260.1 1978 29.0 24.9 19.8 26.1 135.5 405.7 375.2 238.1 144.0 85.7 56.8 40.8 132.4 1979 30.8 26.2 23.4 31.8 625.1 928.0 741.5 265.5 214.2 201.6 134.1 61.7 275.1 1980 39.6 29.3 24.5 24.7 152.5 863.0 929.8 555.5 508.1 129.5 62.0 37.0 280.8 1981 27.0 20.4 16.3 25.5 248.6 312.6 723.9 776.4 142.2 113.6 67.6 35.5 211.5 1982 37.2 41.2 26.8 22.2 140.9 868.4 823.4 414.0 566.4 160.0 56.2 43.5 267.3 1983 30.5 23.5 25.5 34.6 314.8 738.2 401.4 574.6 352.2 391.4 95.2 51.6 254.1 1984 35.2 30.2 21.9 21.5 278.6 702.9 523.5 512.3 260.6 148.2 55.8 40.3 220.4 1985 31.8 21.0 17.9 17.2 183.9 748.1 920.5 772.6 651.3 208.5 58.2 37.7 307.4 1986 33.5 29.0 18.6 19.5 125.6 380.9 397.9 281.4 357.9 371.4 103.9 51.2 181.8 1987 28.4 25.3 21.6 27.7 177.3 447.7 463.5 427.0 381.0 123.5 60.2 41.3 186.2 1988 31.6 22.8 23.7 28.5 209.9 563.3 400.8 287.9 213.3 139.5 67.5 45.2 170.2 1989 33.1 27.7 22.8 34.7 204.0 624.7 435.2 355.8 372.9 182.7 64.2 49.2 201.2 1990 37.7 28.9 23.1 68.0 648.9 721.5 274.5 245.1 530.4 117.4 61.0 49.3 234.3 1991 39.7 34.9 29.7 33.5 248.5 674.7 402.6 182.3 155.7 128.1 55.3 36.4 168.9 1992 31.2 23.9 20.9 25.0 157.2 540.1 303.5 222.1 177.1 81.9 50.3 35.7 139.4 1993 28.7 26.7 22.7 43.5 463.2 596.8 261.0 292.6 494.7 263.2 110.0 55.5 222.2 1994 41.2 38.9 21.8 37.7 264.3 1,006.0 406.6 285.5 175.2 118.1 61.8 45.9 208.8 1995 35.2 27.9 24.4 37.5 306.2 626.4 380.5 272.3 316.2 113.3 52.8 39.2 186.5 1996 28.8 22.7 18.2 24.9 196.7 275.5 192.6 272.6 146.5 69.1 58.3 36.9 112.5 1997 28.8 25.1 23.0 28.9 239.0 540.3 249.4 372.5 284.5 104.5 55.2 44.8 166.8 1998 36.5 31.4 27.9 32.6 155.2 574.9 325.5 439.6 265.0 150.8 67.5 47.1 180.1 1999 36.3 29.4 23.5 21.1 132.2 560.0 338.9 393.2 212.0 163.3 83.5 59.4 171.7 2000 41.7 33.5 26.3 30.4 184.3 849.9 643.5 324.3 405.4 169.1 75.2 48.4 236.5 2001 31.5 25.9 22.0 27.3 140.1 806.7 357.6 274.7 192.2 92.9 47.6 32.8 171.1 2002 26.6 22.1 19.4 24.7 388.9 410.6 253.8 421.9 425.1 346.8 112.2 54.8 210.1 2003 36.8 31.6 27.5 38.8 163.1 585.4 462.4 361.8 198.1 188.6 72.6 50.5 185.6 2004 36.3 25.3 22.4 35.2 419.3 415.9 214.1 164.8 161.5 211.7 69.9 50.0 153.0 2005 41.9 30.2 25.7 73.3 759.5 1,180.0 575.5 414.7 851.6 206.8 65.0 45.5 356.4 2006 28.7 22.5 20.0 21.4 210.0 480.7 304.5 870.3 236.9 344.1 87.6 47.4 224.7 2007 29.7 23.2 18.2 30.2 151.5 574.3 299.8 376.4 477.3 169.0 71.8 45.4 189.2 2008 33.9 26.6 23.8 19.2 210.1 778.3 654.6 370.3 214.4 98.5 48.0 37.9 210.5 2009 38.8 33.6 27.4 67.8 781.7 688.6 415.1 395.6 186.9 181.9 75.9 46.0 246.6 2010 35.0 30.0 29.1 34.7 268.7 319.9 356.3 369.9 255.7 --- ------ --- Average 31 25 21 27 240 661 485 409 306 148 64 41 206 Maximum 54 41 30 73 782 1,215 1,047 909 852 391 134 62 356 Minimum 18 14 10 10 53 276 193 165 82 51 25 17 101 ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 7 of 41 06/01/2011 Table 4: Average Flows (cfs) at USGS Gage 15291000 - Susitna River near Denali Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Annual 1957 --- --- --- --- --- 12,210 11,170 9,769 4,017 1,277 610 288 --- 1958 219 150 120 210 1,163 8,367 9,150 6,536 1,879 939 390 170 2,457 1959 119 81 42 43 1,782 8,891 8,333 7,882 2,498 1,577 760 575 2,733 1960 444 321 275 265 3,349 5,237 9,039 7,910 4,817 1,781 660 483 2,904 1961 331 271 281 415 2,959 6,412 8,078 7,253 2,695 1,290 680 440 2,612 1962 280 240 220 280 2,197 9,087 10,220 9,454 3,649 1,079 510 310 3,148 1963 250 230 200 210 3,253 6,763 10,500 10,210 3,949 925 290 185 3,107 1964 140 140 110 130 910 11,630 7,577 6,552 2,633 1,468 702 279 2,698 1965 220 200 208 320 2,464 4,647 6,756 5,764 6,955 920 300 240 2,427 1966 210 200 200 280 1,629 6,850 8,287 6,432 3,200 --- --- --- --- 1968 --- --- --- --- --- --- 11,840 9,825 2,192 700 304 172 --- 1969 145 140 145 229 1,768 8,146 9,445 3,919 2,213 1,002 501 339 2,346 1970 265 221 193 319 2,210 5,013 8,454 6,216 1,946 528 395 276 2,188 1971 170 125 120 135 629 8,099 10,410 10,400 3,288 1,039 478 380 2,962 1972 339 307 287 270 3,468 6,562 10,450 8,664 2,778 667 323 211 2,886 1973 178 164 153 153 1,042 5,741 8,346 7,268 2,445 876 462 366 2,284 1974 310 271 235 262 2,541 5,642 9,547 9,292 5,452 2,135 673 381 3,085 1975 300 200 200 200 1,640 7,040 12,110 7,295 3,571 1,539 375 169 2,910 1976 112 97 90 123 1,805 5,939 8,558 10,080 1,822 894 467 331 2,551 1977 267 240 231 246 1,498 8,253 10,010 10,180 3,707 1,148 652 439 3,094 1978 348 300 246 263 2,031 5,250 8,993 8,644 3,622 865 463 312 2,633 1979 263 229 203 250 2,791 7,650 9,504 9,178 4,512 2,165 878 533 3,202 1980 395 330 290 280 1,889 6,413 11,750 7,167 2,643 1,298 745 473 2,830 1981 344 274 236 210 3,010 7,162 11,860 12,010 2,742 831 481 326 3,322 1982 227 157 127 120 2,457 5,866 9,749 6,454 4,448 1,153 439 363 2,649 1983 330 300 277 281 1,969 7,455 10,460 8,045 2,597 1,224 433 277 2,826 1984 220 205 200 196 2,049 8,381 10,780 8,816 2,147 1,305 611 438 2,969 1985 357 306 291 376 2,481 8,058 10,490 7,223 3,860 1,269 589 404 2,995 1986 304 238 201 229 2,671 7,060 13,240 --- --- --- --- --- --- Average 262 220 199 233 2,135 7,279 9,831 8,159 3,296 1,181 52 5 339 2,793 Maximum 444 330 291 415 3,468 12,210 13,240 12,010 6,955 2,165 878 575 3,322 Minimum 112 81 42 43 629 4,647 6,756 3,919 1,822 528 290 169 2,1 88 ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 8 of 41 06/01/2011 Table 5: Average Flows (cfs) at USGS Gage 15291200 - Maclaren River near Paxson Table 6: Average Flows (cfs) at USGS Gage 15291500 - Susitna River near Cantwell Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Annual 1958 --- --- --- --- --- 3,532 3,525 2,699 784 378 115 123 --- 1959 129 95 63 78 587 2,879 2,680 2,083 856 549 250 190 875 1960 150 110 94 92 1,742 2,124 3,359 3,048 2,439 687 195 149 1,191 1961 110 94 96 145 1,237 2,678 3,369 3,299 1,168 381 210 170 1,088 1962 120 100 92 120 632 2,916 3,265 2,927 1,127 383 210 130 1,008 1963 100 91 80 83 2,131 3,110 4,649 3,136 1,213 416 140 98 1,282 1964 85 88 71 72 386 4,297 2,764 2,224 871 379 147 49 956 1965 44 42 41 62 984 2,268 3,223 2,409 2,098 522 180 55 1,000 1966 45 45 43 50 265 2,990 2,505 2,095 954 369 95 70 797 1967 65 60 55 53 1,023 3,634 3,255 3,605 1,416 417 130 100 1,158 1968 97 95 95 95 208 3,245 3,427 2,129 680 265 121 69 882 1969 58 55 58 95 849 2,613 2,692 974 470 249 117 73 696 1970 59 50 53 69 746 1,751 2,441 2,367 773 301 192 131 751 1971 83 60 55 66 365 3,414 3,528 3,659 1,165 375 156 123 1,095 1972 115 107 97 99 1,218 3,069 3,255 2,676 1,366 550 243 136 1,084 1973 87 65 53 51 576 2,906 2,856 2,271 821 308 123 83 855 1974 69 62 57 57 649 2,069 2,634 2,439 1,543 385 232 140 867 1975 115 110 100 103 768 3,178 3,649 1,982 1,574 553 235 139 1,047 1976 106 94 90 105 781 2,870 2,810 2,604 600 302 168 119 893 1977 97 92 90 93 367 3,942 3,834 3,394 1,297 512 265 187 1,187 1978 162 140 121 134 709 2,317 3,196 2,356 924 307 192 142 898 1979 122 110 100 111 634 2,430 3,056 2,223 1,137 734 370 246 945 1980 160 106 82 81 901 2,516 3,534 2,471 917 368 257 202 974 1981 159 130 111 95 1,164 2,504 3,666 4,122 1,113 443 230 170 1,169 1982 138 93 77 69 496 1,941 2,735 1,676 1,558 517 287 199 820 1983 148 123 117 123 853 2,751 3,001 2,536 1,196 481 200 121 977 1984 95 90 83 88 967 3,143 2,942 2,400 598 278 164 128 921 1985 113 102 107 110 1,562 4,233 3,344 1,531 1,143 380 145 101 1,077 1986 100 100 115 105 992 2,613 4,756 --- --- --- --- --- --- Average 105 90 82 89 850 2,894 3,240 2,548 1,136 421 192 130 981 Maximum 162 140 121 145 2,131 4,297 4,756 4,122 2,439 734 370 246 1,282 Minimum 44 42 41 50 208 1,751 2,441 974 470 249 95 49 696 Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Annual 1961 --- --- --- --- 9,688 15,710 14,820 16,700 6,725 3,281 1,800 1,400 --- 1962 1,300 1,000 940 1,200 10,000 28,320 20,890 16,000 9,410 4,326 2,200 1,400 8,116 1963 1,000 850 760 720 11,340 15,000 22,790 18,190 9,187 3,848 1,300 877 7,214 1964 644 586 429 465 2,806 34,630 17,040 11,510 5,352 3,134 1,911 921 6,625 1965 760 680 709 1,097 8,818 16,430 18,350 13,440 12,910 3,116 1,000 750 6,538 1966 700 650 650 875 4,387 18,500 12,220 12,680 6,523 2,322 780 720 5,103 1967 680 640 560 513 9,452 19,620 16,880 19,190 10,280 3,084 1,490 1,332 7,018 1968 1,232 1,200 1,200 1,223 9,268 19,500 17,480 10,940 5,410 2,406 1,063 618 5,992 1969 508 485 548 998 7,471 12,330 13,510 6,597 3,376 1,638 815 543 4,094 1970 437 426 463 887 7,580 9,909 13,900 12,320 5,211 2,155 1,530 1,048 4,693 1971 731 503 470 529 1,915 21,970 18,130 22,710 9,800 4,058 2,050 1,371 7,056 1972 1,068 922 881 876 9,694 20,000 16,690 15,620 9,423 --- --- --- --- 1980 --- --- --- --- --- 17,370 20,460 14,870 8,570 5,472 2,487 1,658 --- 1981 1,694 1,186 919 1,218 12,150 14,020 20,870 22,760 9,417 3,829 1,627 1,297 7,646 1982 1,061 698 573 573 8,219 16,500 16,540 11,010 9,942 3,309 1,600 1,400 5,982 1983 1,300 1,200 1,148 1,210 8,196 16,460 16,250 17,000 8,656 5,377 2,130 1,600 6,751 1984 1,500 1,500 1,481 1,403 8,571 18,810 17,700 14,260 5,137 2,758 1,632 1,167 6,362 1985 990 880 844 1,028 5,541 15,810 19,880 12,730 7,522 3,087 1,367 891 5,916 1986 729.4 674.3 660 734.7 7,245 15,490 18,890 --- --- --- ------ --- Average 961 828 779 915 7,908 18,230 17,542 14,918 7,936 3,365 1,575 1,117 6,340 Maximum 1,694 1,500 1,481 1,403 12,150 34,630 22,790 22,760 12,910 5,472 2,487 1,658 8,116 Minimum 437 426 429 465 1,915 9,909 12,220 6,597 3,376 1,638 780 543 4,094 ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 9 of 41 06/01/2011 Table 7: Average Flows (cfs) at USGS Gage 15292000 - Susitna River at Gold Creek Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Annual 1949 --- --- --- --- --- --- --- 24,250 15,650 6,335 2,583 1,43 9 --- 1950 1,027 788 726 870 11,510 19,600 22,600 19,880 8,301 3,84 8 1,300 1,100 7,687 1951 960 820 740 1,617 14,090 20,790 22,570 19,670 21,240 5,571 2,744 1,900 9,439 1952 1,600 1,000 880 920 5,419 32,370 26,390 20,920 14,480 8,202 3,497 1,700 9,820 1953 1,100 820 820 1,615 19,270 27,320 20,200 20,610 15,270 5,604 2,100 1,500 9,738 1954 1,300 1,000 780 1,235 17,280 25,250 20,360 26,100 12,92 0 5,370 2,760 2,045 9,762 1955 1,794 1,400 1,100 1,200 9,319 29,860 27,560 25,750 14,290 4,951 1,900 1,300 10,087 1956 980 970 940 950 17,660 33,340 31,090 24,530 18,330 5,806 3,050 2,142 11,712 1957 1,700 1,500 1,200 1,200 13,750 30,160 23,310 20,540 19,800 8,212 3,954 3,264 10,758 1958 1,965 1,307 1,148 1,533 12,900 25,700 22,880 22,540 7,550 4,811 2,150 1,513 8,891 1959 1,448 1,307 980 1,250 15,990 23,320 25,000 31,180 16,92 0 6,558 2,850 2,200 10,824 1960 1,845 1,452 1,197 1,300 15,780 15,530 22,980 23,590 20,510 7,794 3,000 2,694 9,872 1961 2,452 1,754 1,810 2,650 17,360 29,450 24,570 22,100 13,370 5,916 2,700 2,100 10,575 1962 1,900 1,500 1,400 1,700 12,590 43,270 25,850 23,550 15,890 6,723 2,800 2,000 11,633 1963 1,600 1,500 1,000 830 19,030 26,000 34,400 23,670 12,32 0 6,449 2,250 1,494 10,961 1964 1,048 966 713 745 4,307 50,580 22,950 16,440 9,571 6,291 2,799 1,211 9,807 1965 960 860 900 1,360 12,990 25,720 27,840 21,120 19,350 7,205 2,098 1,631 10,225 1966 1,400 1,300 1,300 1,775 9,645 32,950 19,860 21,830 11,750 4,163 1,600 1,500 9,121 1967 1,500 1,400 1,200 1,167 15,480 29,510 26,800 32,620 16,870 4,900 2,353 2,055 11,390 1968 1,981 1,900 1,900 1,910 16,180 31,550 26,420 17,170 8,816 3,822 1,630 882 9,560 1969 724 723 816 1,510 11,050 15,500 16,100 8,879 5,093 3,124 1,215 866 5,502 1970 824 768 776 1,080 11,380 18,630 22,660 19,980 9,121 5,28 8 3,407 2,290 8,076 1971 1,442 1,036 950 1,082 3,745 32,930 23,950 31,910 14,440 5,847 3,093 2,510 10,291 1972 2,239 2,028 1,823 1,710 21,890 34,430 22,770 19,290 12,400 4,826 2,253 1,465 10,641 1973 1,200 1,200 1,000 1,027 8,235 27,800 18,250 20,290 9,074 3,733 1,523 1,034 7,897 1974 874 777 724 992 16,180 17,870 18,800 16,220 12,250 3,739 1,700 1,603 7,694 1975 1,516 1,471 1,400 1,593 15,350 32,310 27,720 18,090 16,310 7,739 1,993 1,081 10,595 1976 974 950 900 1,373 12,620 24,380 18,940 19,800 6,881 3,87 4 2,650 2,403 8,027 1977 1,829 1,618 1,500 1,680 12,680 37,970 22,870 19,240 12,640 7,571 3,525 2,589 10,511 1978 2,029 1,668 1,605 1,702 11,950 19,050 21,020 16,390 8,607 4,907 2,535 1,681 7,810 1979 1,397 1,286 1,200 1,450 13,870 24,690 28,880 20,460 10,770 7,311 4,192 2,416 9,892 1980 1,748 1,466 1,400 1,670 12,060 29,080 32,660 20,960 13,280 7,725 3,569 1,915 10,689 1981 2,013 1,975 1,585 2,040 16,550 19,300 33,940 37,870 13,790 7,463 3,260 1,877 11,910 1982 1,681 1,486 1,347 1,783 13,380 26,100 24,120 15,270 17,780 6,892 2,633 2,358 9,608 1983 2,265 1,996 1,690 1,900 14,950 24,510 21,150 24,500 13,590 8,301 3,153 2,258 10,079 1984 2,048 1,969 1,900 1,810 12,960 26,770 23,540 20,400 9,429 5,670 3,093 2,394 9,382 1985 1,939 1,643 1,726 1,977 11,170 26,330 26,510 19,920 15,640 6,944 2,673 1,929 9,915 1986 1,658 1,561 1,394 1,565 12,080 20,010 21,870 17,250 12,860 12,680 3,450 1,955 9,084 1987 1,615 1,518 1,500 2,048 12,990 23,000 29,890 21,750 13,340 5,924 2,483 1,600 9,868 1988 1,561 1,500 1,500 1,587 17,370 29,720 25,690 19,540 13,780 7,674 3,013 2,000 10,467 1989 2,000 1,800 1,800 2,137 13,740 26,770 23,650 22,390 15,430 8,025 2,997 1,848 10,267 1990 1,765 1,700 1,852 4,250 25,630 33,800 23,510 23,730 26,510 6,895 2,447 2,200 12,906 1991 1,897 1,800 1,619 1,613 6,048 25,630 21,220 18,280 12,350 5,817 2,440 2,200 8,441 1992 1,965 1,800 1,868 2,100 6,104 23,140 25,540 21,150 10,170 4,379 2,733 2,039 8,628 1993 1,865 1,754 1,639 2,537 20,880 23,480 19,350 18,750 21,290 9,915 3,327 2,529 10,660 1994 2,058 1,786 1,526 3,221 14,610 31,090 20,960 18,580 9,357 4,530 2,780 2,097 9,421 1995 1,855 1,718 1,700 2,846 17,710 24,710 25,500 18,380 19,140 6,482 2,657 1,442 10,394 1996 1,248 1,186 1,100 1,350 6,613 15,710 16,010 17,130 10,410 --- --- --- --- 2001 --- --- --- --- --- 31,000 22,050 21,790 10,360 4,840 2,627 1,897 --- 2002 1,548 1,421 1,303 1,330 11,510 16,550 18,150 23,780 16,250 10,950 5,394 2,590 9,288 2003 1,655 2,243 1,509 2,173 8,019 24,330 29,200 21,120 13,510 8,109 2,500 1,810 9,732 2004 1,471 1,276 1,081 2,730 23,570 25,330 20,160 17,720 6,452 3,300 1,733 1,610 8,930 2005 1,439 1,239 1,045 2,611 26,940 34,320 26,760 21,970 22,860 8,238 2,143 1,497 12,650 2006 1,400 1,389 1,361 1,535 15,730 23,290 23,140 30,810 12,300 10,390 3,140 2,319 10,648 2007 2,024 1,905 1,744 2,273 17,190 19,710 21,580 19,260 13,500 5,017 3,222 2,813 9,241 2008 1,842 1,343 1,360 1,670 11,860 21,120 22,030 19,730 14,520 5,529 1,548 1,300 8,703 2009 1,385 1,300 1,340 4,547 22,930 23,110 19,370 18,470 12,480 7,122 2,807 1,842 9,783 2010 1,468 1,350 1,305 1,847 19,610 20,020 27,520 20,080 15,820 --- --- --- --- Average 1,590 1,414 1,297 1,753 14,138 26,417 23,871 21,365 13,741 6,345 2,679 1,892 9,805 Maximum 2,452 2,243 1,900 4,547 26,940 50,580 34,400 37,870 26,510 12,680 5,394 3,264 12,906 Minimum 724 723 713 745 3,745 15,500 16,010 8,879 5,093 3,124 1,215 866 5,502 ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 10 of 41 06/01/2011 Table 8: Average Flows (cfs) at USGS Gage 15292400 - Chulitna River near Talkeetna Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Annual 1958 --- 1,044 948 1,220 10,460 23,170 25,010 20,760 8,000 4,197 1,883 1,262 --- 1959 1,097 1,049 738 890 7,413 23,660 25,650 22,100 9,957 4,723 2,283 1,700 8,491 1960 1,448 1,103 933 1,000 13,890 17,390 23,650 19,320 12,420 5,135 1,950 1,745 8,393 1961 1,452 1,100 1,079 1,600 10,100 20,490 27,420 24,580 16,030 5,777 2,400 1,500 9,522 1962 1,300 1,000 930 1,170 7,743 20,620 27,220 21,980 13,490 3,506 1,500 1,552 8,555 1963 1,600 1,300 846 700 11,060 17,750 28,950 18,390 11,330 8,062 2,300 1,000 8,674 1964 1,007 820 770 1,133 2,355 40,330 24,430 20,250 9,235 5,642 2,900 2,100 9,271 1965 1,600 1,400 1,300 1,400 7,452 20,070 23,230 22,550 22,260 6,071 1,620 1,350 9,232 1966 1,200 1,100 1,100 1,300 3,971 21,740 23,750 27,720 12,200 4,682 1,680 1,500 8,548 1967 1,458 1,257 1,045 972 12,400 25,520 35,570 33,670 12,510 3,483 1,660 1,397 10,999 1968 1,235 1,200 1,148 1,347 10,940 29,000 30,140 20,710 7,375 2,898 1,480 1,139 9,107 1969 974 900 824 1,333 6,001 18,560 20,820 11,300 6,704 4,578 1,887 1,316 6,301 1970 1,200 1,154 1,100 1,437 9,643 19,670 26,100 24,660 11,330 3,826 2,210 1,403 8,706 1971 1,113 950 934 982 4,468 22,180 27,280 23,810 11,080 5,439 2,157 1,432 8,541 1972 1,174 1,041 939 893 9,765 17,900 25,770 20,970 12,120 --- --- --- --- 1980 --- --- --- --- 9,142 22,490 34,950 20,780 8,240 5,711 3,213 2,016 --- 1981 1,623 1,414 1,171 1,440 9,972 22,420 29,860 33,170 11,960 4,828 2,253 1,219 10,189 1982 1,031 873 789 1,072 6,289 18,360 25,610 20,360 18,240 5,499 2,513 1,853 8,587 1983 1,573 1,039 1,050 1,248 8,881 18,890 22,320 22,190 10,960 8,618 2,923 2,387 8,568 1984 2,045 1,507 1,258 1,377 7,315 18,600 22,270 22,780 9,921 4,726 2,673 2,161 8,106 1985 1,903 1,396 1,165 1,130 5,713 18,900 27,150 20,780 13,150 6,361 1,900 1,481 8,473 1986 1,316 1,132 959 956 4,755 14,710 22,840 --- --- --- --- --- --- Average 1,367 1,132 1,001 1,171 8,169 21,474 26,363 22,516 11,834 5,188 2,169 1,576 8,792 Maximum 2,045 1,507 1,300 1,600 13,890 40,330 35,570 33,670 22,260 8,618 3,213 2,387 10,999 Minimum 974 820 738 700 2,355 14,710 20,820 11,300 6,704 2,898 1,480 1,000 6,301 ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 11 of 41 06/01/2011 Table 9: Average Flows (cfs) at USGS Gage 15292700 - Talkeetna River near Talkeetna Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Annual 1964 --- --- --- --- --- 17,080 9,820 8,396 3,815 3,115 1,568 1,100 --- 1965 720 620 540 580 3,474 11,090 12,180 11,150 10,610 4,438 1,460 876 4,834 1966 711 526 395 422 2,410 12,970 10,100 10,730 5,370 2,388 897 750 3,990 1967 637 546 471 427 4,112 9,286 12,600 14,160 6,971 2,029 1,253 987 4,488 1968 851 777 743 983 8,840 14,100 11,230 7,546 4,120 1,637 827 557 4,373 1969 459 401 380 519 3,869 5,207 7,080 3,787 2,070 1,450 765 587 2,230 1970 504 458 440 545 3,950 7,979 10,320 8,752 5,993 2,817 1,647 1,103 3,732 1971 679 459 402 503 2,145 19,040 11,760 16,770 5,990 2,632 1,310 845 5,234 1972 727 628 481 519 3,516 12,700 12,030 9,576 8,709 3,630 1,373 889 4,583 1973 748 654 574 577 3,860 12,210 7,676 9,927 3,861 1,807 960 745 3,649 1974 645 559 482 535 5,678 8,030 7,755 7,704 4,763 1,967 1,002 774 3,344 1975 694 586 508 522 4,084 13,180 12,070 8,487 7,960 2,884 773 558 4,376 1976 524 480 470 613 3,439 10,580 9,026 8,088 3,205 1,857 1,105 1,069 3,390 1977 700 549 506 548 4,244 18,280 9,344 8,005 5,963 3,268 1,121 860 4,459 1978 746 576 485 534 2,950 7,429 10,790 7,001 3,567 1,660 1,138 932 3,172 1979 762 652 577 710 7,790 12,010 14,440 8,274 4,039 3,379 1,718 868 4,634 1980 808 741 700 1,038 4,823 11,380 13,900 7,224 5,402 2,600 1,144 717 4,229 1981 652 535 546 671 4,529 6,589 15,410 14,680 4,384 2,346 1,236 708 4,401 1982 650 467 285 480 3,313 12,940 11,070 7,271 9,555 3,351 1,243 1,082 4,321 1983 836 580 566 669 4,551 9,013 8,703 8,803 3,944 3,280 1,097 781 3,592 1984 690 626 600 555 4,008 9,328 8,896 9,762 3,816 2,197 1,158 897 3,567 1985 717 548 498 522 4,174 10,400 11,140 10,180 8,425 3,317 1,002 783 4,331 1986 681 590 400 396 2,538 6,209 9,149 8,032 6,889 10,000 1,992 1,122 4,029 1987 832 737 659 894 5,062 9,712 11,070 9,872 5,358 1,723 1,137 965 4,026 1988 818 707 607 595 5,271 10,110 9,675 7,974 5,123 2,504 1,133 965 3,810 1989 697 577 550 600 3,628 10,660 8,356 12,410 8,550 4,102 1,553 1,050 4,415 1990 997 990 1,058 1,912 11,510 13,110 8,451 8,706 11,000 2,206 820 673 5,136 1991 610 407 340 716 6,163 12,780 9,972 6,361 4,077 1,898 672 540 3,729 1992 494 480 521 690 2,800 10,370 11,170 8,528 3,992 1,573 1,213 961 3,586 1993 716 552 502 907 10,190 11,570 9,208 8,387 12,090 5,151 1,660 968 5,181 1994 790 675 531 1,053 6,920 13,600 8,643 8,827 3,014 1,813 973 773 3,987 1995 637 548 540 629 6,738 10,260 10,220 7,483 7,629 2,502 1,089 538 4,088 1996 457 440 467 749 4,721 6,179 8,066 8,373 3,601 1,424 808 698 3,021 1997 616 545 478 609 3,794 7,607 10,250 10,470 5,384 1,590 718 569 3,577 1998 481 446 413 660 3,988 10,440 11,120 9,241 6,331 3,059 1,242 873 4,047 1999 666 486 374 492 3,668 9,691 9,476 11,420 4,439 2,737 1,267 834 3,821 2000 648 562 500 658 4,492 15,190 13,840 6,336 6,234 3,201 1,253 869 4,499 2001 715 598 526 613 3,623 12,340 8,008 8,357 4,146 2,025 943 665 3,560 2002 539 493 430 439 7,203 6,543 7,210 10,150 8,700 5,742 2,400 1,020 4,267 2003 464 513 417 1,025 4,443 9,840 12,050 8,271 4,455 2,920 1,383 816 3,908 2004 656 541 482 843 7,532 8,711 8,947 7,231 2,992 2,779 1,225 777 3,586 2005 682 579 666 1,967 14,240 16,470 10,940 8,697 10,960 3,704 880 771 5,905 2006 671 514 479 573 4,675 7,698 9,054 13,320 5,439 6,152 1,458 665 4,260 2007 500 382 309 717 3,266 5,481 8,522 8,591 6,699 2,686 1,058 615 3,256 2008 479 414 416 531 3,795 8,518 8,455 8,542 5,442 2,449 873 694 3,403 2009 654 547 517 823 7,791 8,873 7,956 6,712 4,541 3,531 1,679 834 3,728 2010 665 575 515 763 4,502 6,859 9,931 9,219 5,800 --- --- --- --- Average 666 562 508 703 5,050 10,631 10,151 9,102 5,860 2,946 1,201 820 4,039 Maximum 997 990 1,058 1,967 14,240 19,040 15,410 16,770 12,090 10,000 2,400 1,122 5,905 Minimum 457 382 285 396 2,145 5,207 7,080 3,787 2,070 1,424 672 538 2,230 ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 12 of 41 06/01/2011 Table 10: Average Flows (cfs) at USGS Gage 15292780 - Susitna River at Sunshine Table 11: Average Flows (cfs) at USGS Gage 15292800 - Montana Creek near Montana Table 12: Average Flows (cfs) at USGS Gage 15294005 - Willow Creek Near Willow Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Annual 1981 --- --- --- --- 36,160 50,890 85,600 84,940 32,460 16,450 7,030 4,035 --- 1982 3,500 3,229 2,877 3,803 26,560 62,820 63,030 45,590 48,830 16,180 6,300 5,613 24,128 1983 5,216 4,664 3,481 4,197 31,390 58,100 55,380 60,580 30,010 21,340 8,273 5,555 24,162 1984 4,897 4,600 4,497 4,553 25,920 59,280 59,140 58,720 23,950 12,350 6,253 4,877 22,554 1985 4,565 3,821 3,748 4,087 25,750 60,870 68,040 55,030 40,760 16,680 6,077 4,306 24,610 1986 3,697 3,379 2,877 3,100 22,040 46,870 --- --- --- --- ------ --- Average 4,375 3,939 3,496 3,948 27,970 56,472 66,238 60,972 35,202 16,600 6,787 4,877 23,864 Maximum 5,216 4,664 4,497 4,553 36,160 62,820 85,600 84,940 48,830 21,340 8,273 5,613 24,610 Minimum 3,500 3,229 2,877 3,100 22,040 46,870 55,380 45,590 23,950 12,350 6,077 4,035 22,554 Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Annual 2005 --- --- --- --- 1,497.0 828.5 262.6 332.4 885.3 260.4 57.2 51.3 --- 2006 42.6 31.0 31.0 35.4 539.5 520.0 418.0 1,347.0 854.0 --- --- --- --- 2008 --- --- --- --- --- 570.9 454.6 405.0 377.3 222.5 57.1 36.0 --- 2009 35.7 30.8 30.6 60.2 1,117.0 477.3 158.0 323.9 249.3 255.4 94.6 53.0 242.4 2010 39.8 36.2 32.1 66.9 399.5 335.9 437.4 470.8 339.8 --- ------ --- Average 39 33 31 54 888 547 346 576 541 246 70 47 242 Maximum 43 36 32 67 1,497 829 455 1,347 885 260 95 53 242 Minimum 36 31 31 35 400 336 158 324 249 223 57 36 242 Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Annual 1978 --- --- --- --- --- 646.9 606.7 307.0 258.8 232.4 90.9 110.0 --- 1979 83.4 74.3 75.0 99.5 1,055.0 1,430.0 1,154.0 398.3 368.2 402.3 364.1 152.0 473.6 1980 112.3 85.4 73.2 102.3 472.5 1,411.0 1,287.0 954.7 699.6 287.8 127.1 57.3 474.5 1981 57.1 52.9 57.7 85.7 481.2 484.3 1,019.0 1,286.0 367.3 398.5 176.7 99.5 384.3 1982 96.0 74.2 33.7 74.8 579.0 1,186.0 815.8 500.2 1,077.0 409.0 150.2 118.7 427.0 1983 93.7 77.6 63.6 103.0 599.6 888.5 337.8 766.2 564.6 631.4 170.0 118.1 369.5 1984 94.6 84.2 71.9 74.5 393.7 828.1 578.7 537.1 380.1 176.8 81.5 69.0 281.8 1985 66.0 70.0 66.6 65.8 339.6 1,344.0 1,233.0 1,130.0 951.7 418.8 131.0 91.5 494.4 1986 69.2 53.0 42.3 50.5 370.7 607.8 668.7 612.3 704.8 1,197.0 190.8 137.1 394.8 1987 101.0 77.2 61.4 87.1 496.8 823.3 573.4 580.7 631.7 263.9 95.8 80.4 323.8 1988 66.6 74.3 62.3 87.9 631.7 996.9 672.0 563.3 586.6 408.0 185.3 127.7 373.3 1989 90.3 73.6 68.9 140.6 576.9 1,142.0 541.4 783.5 808.5 475.3 214.9 138.2 422.3 1990 109.1 98.8 97.5 204.7 1,578.0 1,500.0 481.1 378.4 1,142.0 321.3 180.7 143.9 520.5 1991 104.2 83.0 71.1 89.2 782.4 1,230.0 703.9 401.9 463.2 269.3 165.4 126.1 375.3 1992 93.1 72.5 58.8 67.4 456.0 1,256.0 581.8 439.8 437.1 187.7 101.7 76.3 319.4 1993 62.3 60.0 64.2 75.2 968.0 1,020.0 356.1 439.3 1,177.0 --- --- --- --- 2001 --- --- --- --- 376.1 1,471.0 660.3 457.4 324.8 189.5 94.8 70.6 --- 2002 60.2 56.4 49.7 45.8 664.1 661.7 310.4 666.5 904.7 794.0 246.3 130.0 384.3 2003 94.2 134.3 59.4 97.6 328.5 789.7 495.8 469.4 400.8 449.4 169.1 83.2 298.2 2004 70.2 57.6 50.0 85.2 828.6 633.6 228.3 210.4 340.4 622.4 163.9 122.6 286.1 2005 110.7 91.9 75.3 257.7 1,623.0 1,583.0 700.7 650.9 1,262.0 402.8 100.0 70.6 578.9 2006 60.3 54.5 51.3 50.1 555.2 927.9 558.4 1,685.0 653.6 789.8 211.7 114.7 479.7 2007 79.0 65.9 49.9 84.2 359.2 579.9 362.1 412.4 631.7 300.2 119.3 72.1 260.2 2008 60.0 52.4 51.4 66.0 414.2 822.0 744.8 552.8 504.7 262.4 126.7 102.7 314.8 2009 88.1 56.7 50.2 117.2 942.7 707.8 336.7 370.0 290.2 353.6 133.6 106.4 297.9 2010 93.7 69.3 48.2 74.1 457.2 540.7 562.9 527.8 529.3 --- ------ --- Average 84 73 61 95 653 981 637 619 633 427 158 105 388 Maximum 112 134 98 258 1,623 1,583 1,287 1,685 1,262 1,197 364 152 579 Minimum 57 52 34 46 329 484 228 210 259 177 82 57 260 ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 13 of 41 06/01/2011 Table 13: Average Flows (cfs) at USGS Gage 15294010 - Deception Creek near Willow Table 14: Average Flows (cfs) at USGS Gage 15294100 - Deshka River near Willow Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Annual 1978 --- --- --- --- --- 88.5 78.4 26.2 31.7 57.4 21.8 25.5 --- 1979 17.5 16.2 25.2 76.8 312.9 91.1 124.3 39.7 55.0 79.2 148.8 46.0 86.6 1980 33.1 23.5 22.2 73.4 140.6 165.4 109.5 102.3 112.8 97.5 28.7 4.1 76.3 1981 6.8 11.1 10.4 28.2 99.6 48.7 142.4 188.3 82.4 126.5 43.1 26.4 68.5 1982 11.6 5.2 2.9 9.4 75.0 93.1 129.0 62.6 203.3 78.2 39.8 35.5 62.3 1983 22.0 17.4 15.8 31.9 173.6 80.2 28.0 83.8 62.8 34.6 32.0 26.5 51.0 1984 21.3 21.7 21.3 40.4 152.9 66.1 44.7 45.3 55.8 27.6 17.3 14.0 44.2 1985 14.5 11.0 9.6 9.8 228.2 128.1 54.6 122.4 125.2 --- --- ------ Average 18 15 15 39 169 95 89 84 91 72 47 25 65 Maximum 33 24 25 77 313 165 142 188 203 127 149 46 87 Minimum 7 5 3 9 75 49 28 26 32 28 17 4 44 Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Annual 1,978 --- --- --- --- --- --- --- --- --- 553 424 329 --- 1,979 290 266 263 774 4,295 876 717 547 790 1,366 2,669 561 1,123 1,980 393 362 332 1,215 2,585 1,631 1,768 1,113 904 1,457 577 232 1,053 1,981 275 216 277 583 1,708 518 2,580 2,714 826 1,557 762 403 1,046 1,982 250 184 177 367 1,706 1,268 852 813 2,561 1,168 407 300 840 1,983 298 257 181 879 2,626 646 247 787 513 1,399 452 303 720 1,984 244 233 290 575 1,884 490 318 913 443 480 327 289 544 1,985 241 210 205 215 4,367 1,911 466 1,332 2,528 1,513 277 235 1,131 1,986 193 182 185 311 1,361 421 488 1,615 2,125 --- --- --- --- 1,998 --- --- --- --- --- --- --- --- --- 939 446 218 --- 1,999 191 188 190 486 2,616 814 474 1,454 1,179 1,748 660 502 882 2,000 377 271 261 344 4,160 670 742 399 773 594 400 348 785 2,001 290 260 283 739 3,495 673 488 856 899 --- --- --- --- Average 277 239 240 590 2,800 902 831 1,140 1,231 1,161 673 338 903 Maximum 393 362 332 1,215 4,367 1,911 2,580 2,714 2,561 1,748 2,669 561 1,131 Minimum 191 182 177 215 1,361 421 247 399 443 480 277 218 544 ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 14 of 41 06/01/2011 Table 15: Average Flows (cfs) at USGS Gage 15294300 - Skwentna River near Skwentna Table 16: Average Flows (cfs) at USGS Gage 15294345 - Yentna River near Susitna Station Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Annual 1959 --- --- --- --- --- --- --- --- --- 3,532.0 1,850.0 1,400.0 --- 1960 1,097 961 843 835 10,480 13,440 16,690 15,990 9,171 3,889 1,600 1,597 6,429 1961 1,403 1,154 1,155 1,700 11,210 20,570 16,480 13,910 12,020 4,605 2,200 1,400 7,348 1962 1,200 860 760 1,000 6,613 15,630 14,930 12,080 6,723 2,801 1,250 1,100 5,442 1963 1,000 810 700 650 7,765 14,050 20,430 12,020 7,180 5,355 1,550 840 6,074 1964 970 750 600 840 1,635 27,250 16,480 12,680 6,224 4,425 1,790 1,300 6,260 1965 920 800 740 770 4,810 17,160 19,370 14,010 13,090 4,122 1,575 1,150 6,573 1966 1,100 1,100 1,100 1,300 4,502 19,550 14,180 17,320 9,812 5,576 1,400 900 6,514 1967 720 650 650 780 1,794 14,430 14,740 15,760 9,517 3,832 1,560 1,181 5,495 1968 1,023 1,000 950 1,293 13,460 20,770 17,480 10,560 3,855 1,929 678 624 6,172 1969 600 600 626 1,487 11,070 19,580 13,650 7,471 3,783 5,654 1,607 832 5,610 1970 766 700 650 728 11,710 22,880 21,120 13,030 6,665 2,919 2,023 1,184 7,072 1971 865 721 613 607 5,963 25,400 20,600 15,920 6,024 3,020 1,327 1,103 6,881 1972 989 898 811 742 8,045 15,330 16,840 13,370 9,256 4,551 2,340 1,316 6,243 1973 910 702 607 727 6,349 15,200 13,850 9,874 6,164 3,540 1,700 1,265 5,100 1974 1,023 902 811 1,005 6,765 10,650 11,670 10,480 11,800 4,557 2,328 919 5,265 1975 800 750 750 767 7,852 19,060 19,520 11,710 8,471 4,704 1,973 1,258 6,503 1976 971 897 800 1,270 8,806 15,120 14,580 11,120 8,165 6,196 2,880 2,871 6,175 1977 2,829 1,821 1,200 1,200 8,906 36,670 25,270 20,160 10,290 5,799 2,373 1,548 9,874 1978 1,213 944 841 1,023 9,006 13,840 18,100 13,740 7,478 4,936 1,580 1,555 6,233 1979 1,165 1,036 981 1,597 11,660 14,980 15,830 16,210 7,448 7,254 4,195 2,226 7,098 1980 1,781 1,617 1,352 1,957 11,850 24,780 28,620 13,860 8,785 5,628 2,687 1,476 8,748 1981 1,237 1,270 926 2,138 22,370 24,670 21,400 16,490 7,639 5,177 2,267 1,481 8,982 1982 1,171 986 777 770 5,165 16,020 13,980 10,460 15,150 --- --- --- --- Average 1,120 953 837 1,095 8,599 19,001 17,644 13,401 8,466 4,522 1,945 1,327 6,640 Maximum 2,829 1,821 1,352 2,138 22,370 36,670 28,620 20,160 15,150 7,254 4,195 2,871 9,874 Minimum 600 600 600 607 1,635 10,650 11,670 7,471 3,783 1,929 678 624 5,100 Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Annual 1980 --- --- --- --- --- --- --- --- --- 18,540 8,367 4,368 --- 1981 3,710 3,736 2,748 5,480 45,640 55,120 64,380 58,860 25,890 12,260 6,247 4,539 24,227 1982 3,661 2,850 2,226 2,177 13,900 40,870 46,740 39,750 47,600 12,510 5,663 4,116 18,573 1983 3,339 3,236 3,087 4,418 25,900 48,800 44,620 47,140 15,750 10,740 5,443 3,577 18,119 1984 2,635 2,308 2,277 5,755 30,880 50,090 52,470 53,390 18,970 13,720 4,373 3,013 20,138 1985 2,961 2,850 2,619 2,500 19,290 48,490 58,760 46,210 29,830 16,250 4,847 3,742 19,985 1986 3,284 2,932 2,497 2,850 22,990 44,610 --- --- --- --- ------ --- Average 3,265 2,985 2,576 3,863 26,433 47,997 53,394 49,070 27,608 14,003 5,823 3,893 20,208 Maximum 3,710 3,736 3,087 5,755 45,640 55,120 64,380 58,860 47,600 18,540 8,367 4,539 24,227 Minimum 2,635 2,308 2,226 2,177 13,900 40,870 44,620 39,750 15,750 10,740 4,373 3,013 18,119 ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 15 of 41 06/01/2011 Table 17: Average Flows (cfs) at USGS Gage 15294350 - Susitna River at Susitna Station III. Monthly Flow Frequency and Flow Duration Flow frequency and flow duration plots were created from daily flow data on the Susitna River at Cantwell, Gold Creek, Sunshine, and Susitna Station, and on the Chulitna River near Talkeetna. Tables 18, 19, 20, 21, and 22 present monthly flow frequencies for flows in the Susitna River at Cantwell and Gold Creek, in the Chulitna River near Talkeetna, and in the Susitna River at Sunshine and Susitna Station, respectively. The flow frequency was calculated at 5% exceedance intervals except at the high and low flow ends where 1% exceedance intervals were used to provide additional definition where the flow duration values change rapidly. Figures 3 through 12 show the flow frequency and flow duration curves for these sites. The flow frequency curves demonstrate the same seasonal flow as Figure 2, with peak flows occurring in June at the middle watershed sites of Cantwell and Gold Creek, June through August in the Chulitna River at Talkeetna, and in July and August at the lower Susitna watershed gage locations at Sunshine and Susitna Station. Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Annual 1974 --- --- --- --- --- --- --- --- --- 19,520 10,400 9,419 --- 1975 8,597 7,804 7,048 6,867 47,540 128,800 135,700 91,360 77,740 31,550 9,933 6,000 46,795 1976 6,529 5,614 5,368 7,253 70,460 107,000 115,200 99,650 48,910 30,140 18,270 13,100 44,258 1977 10,100 8,911 6,774 6,233 56,180 165,900 143,900 125,500 83,810 38,230 12,630 7,529 55,730 1978 6,974 6,771 6,590 7,033 48,670 90,930 117,600 102,100 55,500 36,810 15,000 9,306 42,227 1979 8,823 7,946 7,032 8,683 81,260 119,900 142,500 128,200 74,340 58,640 31,590 14,690 57,352 1980 10,120 9,017 8,906 12,030 66,580 142,900 181,400 126,400 77,970 34,970 16,200 8,516 58,272 1981 7,774 7,589 6,177 10,350 83,580 108,700 152,800 159,600 67,170 33,900 17,570 11,740 56,024 1982 9,032 7,214 5,435 5,817 44,940 108,100 114,800 94,630 109,700 34,010 15,200 9,890 46,743 1983 8,368 8,421 7,123 7,681 62,090 103,900 103,300 107,900 54,870 39,440 19,030 11,480 44,742 1984 7,435 6,703 6,468 13,020 60,430 107,100 109,200 111,000 51,010 30,770 10,950 8,226 43,807 1985 7,968 6,946 6,500 6,817 45,660 112,700 134,700 108,700 84,110 50,690 18,430 11,130 49,814 1986 8,871 7,750 5,974 7,193 47,590 91,000 125,400 101,700 76,980 88,500 17,500 9,345 49,331 1987 7,794 7,500 7,348 9,860 65,360 108,500 138,800 119,900 73,510 34,370 19,080 12,480 50,702 1988 10,690 9,745 9,500 11,120 83,570 135,900 140,600 103,200 70,430 41,440 13,830 7,000 53,390 1989 6,242 6,232 7,000 8,900 70,340 115,500 127,100 154,600 115,700 59,120 18,670 8,839 58,543 1990 8,368 8,211 9,058 21,430 121,000 142,400 119,400 106,900 107,400 33,660 11,380 7,500 58,331 1991 7,500 7,475 6,565 8,617 56,480 134,200 124,100 106,400 71,650 37,450 14,030 12,230 49,142 1992 10,600 9,500 9,694 21,480 55,120 109,200 119,200 87,180 39,230 18,770 13,670 11,260 42,301 1993 9,468 7,696 7,032 --- --- --- --- --- --- --- --- --- --- Average 8,487 7,739 7,136 10,021 64,825 118,479 130,317 113,051 74,446 39,578 15,966 9,983 50,417 Maximum 10,690 9,745 9,694 21,480 121,000 165,900 181,400 159,600 115,700 88,500 31,590 14,690 58,543 Minimum 6,242 5,614 5,368 5,817 44,940 90,930 103,300 87,180 39,230 18,770 9,933 6,000 42,227 ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 16 of 41 06/01/2011 Table 18: Flow (cfs) Frequency at USGS Gage 15291500 – Susitna River near Cantwell % of Time Flow is Exceeded Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Annual (all months) 0 1,800 1,500 1,500 3,000 32,500 49,100 34,000 55,000 21,000 9,400 3,600 1,900 55,000 1 1,800 1,500 1,500 1,800 23,740 43,310 29,400 35,886 18,427 7,353 3,200 1,774 28,775 2 1,700 1,500 1,500 1,682 22,000 37,848 28,000 28,800 17,088 7,000 2,982 1,600 26,000 3 1,700 1,500 1,500 1,500 20,200 35,251 27,036 28,258 16,183 6,536 2,600 1,600 24,000 4 1,696 1,500 1,500 1,400 20,000 33,396 26,248 26,000 16,000 6,070 2,500 1,600 22,100 5 1,600 1,500 1,400 1,400 19,100 32,455 25,860 24,600 15,010 6,000 2,400 1,600 21,000 10 1,500 1,200 1,200 1,400 16,000 27,000 23,100 20,830 13,010 5,200 2,200 1,600 18,000 15 1,300 1,200 1,100 1,226 14,000 25,360 21,800 18,445 12,000 5,000 2,200 1,400 16,000 20 1,300 1,200 940 1,200 12,700 23,240 20,700 17,960 10,520 4,500 2,000 1,400 14,500 25 1,300 1,000 940 1,200 11,300 21,150 19,900 17,100 9,500 4,175 1,900 1,400 12,000 30 1,200 965 900 1,100 10,000 20,000 19,000 16,490 8,624 3,918 1,800 1,400 9,865 35 1,094 904 850 1,070 10,000 19,000 18,600 16,000 8,000 3,600 1,800 1,400 7,100 40 1,000 850 825 1,000 9,380 18,000 18,000 15,800 7,900 3,600 1,700 1,300 4,970 45 1,000 850 760 940 8,660 17,000 17,600 15,200 7,570 3,406 1,600 1,200 3,200 50 970 690 690 900 7,500 16,000 17,000 14,700 7,100 3,200 1,530 1,200 2,100 55 760 680 660 850 6,500 15,805 16,700 14,000 6,786 3,000 1,500 1,080 1,600 60 760 670 650 750 5,200 15,200 16,000 13,100 6,600 2,844 1,486 994 1,400 65 730 650 600 720 3,700 15,000 15,580 12,400 6,230 2,600 1,400 932 1,200 70 700 647 560 660 3,000 14,970 15,000 12,000 5,975 2,400 1,364 860 1,100 75 680 640 550 650 2,500 14,200 14,800 11,400 5,515 2,200 1,100 800 950 80 680 560 550 550 2,200 13,600 14,000 10,700 5,132 2,026 1,100 750 850 85 610 500 480 500 1,700 12,635 13,300 9,856 4,430 1,900 918 720 720 90 500 480 460 500 1,500 11,000 12,200 9,267 3,818 1,800 800 650 650 95 460 440 460 485 800 8,823 11,340 7,637 3,396 1,586 780 565 500 96 440 423 440 467 750 8,381 11,000 7,121 3,200 1,423 780 550 500 97 436 420 431 460 750 7,951 11,000 5,684 3,034 1,239 758 550 480 98 420 420 400 440 710 7,232 10,904 4,728 2,800 1,100 709 500 460 99 420 420 400 440 580 6,980 10,000 4,371 2,515 1,026 655 500 440 100 420 420 400 440 580 6,130 8,550 3,600 2,080 840 600 480 400 ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 17 of 41 06/01/2011 Figure 3: Susitna River Flow Frequency at Cantwell Figure 4: Susitna River Flow Duration at Cantwell 0 5,000 10,000 15,000 20,000 25,000 30,000 35,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov DecDaily Flow (cfs)5% Exceedance 10% Exceedance 25% Exceedance 50% Exceedance 90% Exeedance Based on Historic Recorded Daily Flows in the Susitna River nearCantwell -USGS Gage 15291500 0 5,000 10,000 15,000 20,000 25,000 30,000 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%Daily Flow (cfs)Percent of Time Flow is Equaled or Exceeded Based on Historic Recorded Daily Flowsin the Susitna River near Cantwell -USGS Gage 15291500 ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 18 of 41 06/01/2011 Table 19: Flow (cfs) Frequency at USGS Gage 15292000 – Susitna River at Gold Creek % of Time Flow is Exceeded Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Annual (all months) 0 2,900 3,700 2,400 24,000 55,500 85,900 60,800 77,700 47,700 36,200 8,940 4,400 85,900 1 2,500 2,400 2,100 7,242 37,958 62,003 42,934 51,206 32,305 16,860 5,184 3,500 39,857 2 2,400 2,150 1,900 5,384 35,116 51,782 39,000 43,006 30,300 14,630 4,800 3,200 35,300 3 2,400 2,000 1,900 4,169 33,074 46,473 37,008 39,045 27,900 13,100 4,500 2,900 32,700 4 2,300 2,000 1,900 3,684 31,532 43,428 35,436 34,824 26,088 12,460 4,400 2,800 31,000 5 2,200 2,000 1,900 3,400 31,000 41,710 34,500 32,900 25,000 12,000 4,202 2,713 30,000 10 2,025 1,900 1,800 2,500 27,800 37,110 31,300 29,000 21,710 10,300 3,700 2,500 25,470 15 2,000 1,800 1,700 2,200 24,270 34,265 29,500 26,445 19,500 9,268 3,400 2,400 22,600 20 2,000 1,790 1,600 2,000 22,000 32,420 28,000 25,200 18,000 8,480 3,200 2,300 20,200 25 1,900 1,700 1,600 1,900 20,350 30,600 26,800 24,000 16,900 7,800 3,100 2,200 18,000 30 1,850 1,600 1,500 1,800 18,800 29,300 25,800 23,000 15,600 7,210 3,000 2,200 15,300 35 1,800 1,500 1,500 1,700 17,700 28,000 25,000 22,400 14,700 6,740 2,900 2,100 12,000 40 1,700 1,500 1,400 1,650 16,400 27,000 24,200 21,700 14,000 6,300 2,800 2,000 8,400 45 1,600 1,500 1,350 1,600 15,000 26,000 23,500 21,000 13,200 5,900 2,700 2,000 5,200 50 1,600 1,400 1,300 1,540 13,600 25,350 22,800 20,200 12,500 5,500 2,600 1,900 3,500 55 1,600 1,400 1,300 1,500 12,000 24,300 22,200 19,600 11,900 5,200 2,600 1,900 2,650 60 1,500 1,300 1,200 1,500 10,360 23,300 21,700 18,800 11,300 4,950 2,400 1,700 2,200 65 1,500 1,300 1,100 1,400 9,000 22,200 21,200 18,000 10,665 4,600 2,400 1,700 1,950 70 1,400 1,200 1,000 1,200 7,160 21,200 20,600 17,500 10,100 4,500 2,300 1,600 1,800 75 1,300 1,200 995 1,200 5,050 20,000 19,900 17,000 9,520 4,215 2,100 1,500 1,600 80 1,200 1,000 940 1,100 4,400 18,900 19,200 16,200 8,936 4,000 1,900 1,500 1,500 85 1,100 970 880 1,000 3,400 17,800 18,500 15,400 8,249 3,700 1,700 1,300 1,400 90 960 860 800 920 2,800 16,400 17,560 14,500 7,199 3,400 1,600 1,110 1,200 95 900 800 750 830 2,055 15,000 16,300 12,985 6,000 2,898 1,400 1,000 950 96 850 750 740 830 1,900 14,700 16,000 12,288 5,791 2,784 1,300 1,000 900 97 850 750 740 780 1,700 13,827 15,600 11,800 5,500 2,500 1,300 900 850 98 800 720 700 756 1,500 13,218 15,032 10,988 5,316 2,200 1,200 850 800 99 718 700 660 710 1,400 12,200 14,600 8,088 4,900 1,900 1,100 850 750 100 700 600 660 700 900 10,000 11,800 5,280 3,710 1,500 950 800 600 ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 19 of 41 06/01/2011 Figure 5: Susitna River Flow Frequency at Gold Creek Figure 6: Flow Duration Curve for the Susitna River at Gold Creek 0 5,000 10,000 15,000 20,000 25,000 30,000 35,000 40,000 45,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov DecDaily Flow (cfs)5% Exceedance 10% Exceedance 25% Exceedance 50% Exceedance 90% Exeedance Based on Historic Recorded Daily Flows in theSusitna River at Gold Creek - USGS Gage 15292000 0 5,000 10,000 15,000 20,000 25,000 30,000 35,000 40,000 45,000 50,000 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%Daily Flow (cfs)Percent of Time Flow is Equaled or Exceeded Based on Historic Recorded Daily Flowsin theSusitna River at Gold Creek - USGS Gage 15292000 ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 20 of 41 06/01/2011 Table 20: Flow (cfs) Frequency at USGS Gage 15292400 – Chulitna River at Talkeetna % of Time Flow is Exceeded Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Annual (all months) 0 2,300 1,800 1,300 4,000 35,700 56,000 71,200 73,000 41,100 22,600 4,000 2,600 73,000 1 2,200 1,600 1,300 2,200 26,319 45,000 43,214 49,200 32,739 12,481 3,700 2,500 37,924 2 2,131 1,600 1,300 2,000 22,532 39,328 39,838 40,600 29,642 12,000 3,502 2,400 34,400 3 2,000 1,500 1,300 1,900 21,000 39,000 38,957 38,400 27,265 11,286 3,202 2,400 32,386 4 2,000 1,500 1,300 1,700 20,000 38,000 37,276 36,200 25,488 10,648 3,200 2,400 30,648 5 2,000 1,500 1,300 1,700 19,495 37,000 36,390 35,600 23,275 10,000 3,100 2,300 29,200 10 1,800 1,400 1,200 1,500 16,000 30,600 34,000 32,000 18,700 9,200 3,000 2,100 24,900 15 1,600 1,400 1,200 1,500 14,000 27,015 32,585 28,900 16,000 8,000 2,900 2,100 22,000 20 1,600 1,300 1,200 1,400 12,300 25,520 31,000 26,700 15,000 7,000 2,800 1,900 19,400 25 1,600 1,300 1,100 1,400 11,600 24,300 29,875 25,600 14,000 6,200 2,800 1,800 16,000 30 1,500 1,200 1,100 1,300 10,700 23,600 28,870 25,000 13,000 5,632 2,600 1,700 12,300 35 1,500 1,200 1,100 1,243 10,000 23,000 27,400 24,000 12,100 5,247 2,400 1,600 9,400 40 1,400 1,200 1,050 1,200 9,400 22,200 26,900 23,000 11,700 5,000 2,200 1,600 6,580 45 1,300 1,100 1,000 1,100 8,482 21,800 25,900 22,000 11,000 4,800 2,100 1,500 4,009 50 1,300 1,100 990 1,100 7,200 20,900 25,000 21,400 10,300 4,500 2,000 1,500 2,900 55 1,300 1,100 950 1,000 5,716 20,000 24,700 20,600 10,000 4,246 1,900 1,500 2,100 60 1,200 1,100 950 1,000 5,000 19,000 24,000 20,000 9,500 4,000 1,800 1,460 1,700 65 1,200 1,000 940 1,000 4,200 18,000 23,500 19,500 9,138 3,800 1,800 1,400 1,500 70 1,200 1,000 900 950 3,500 17,100 23,000 19,000 8,528 3,554 1,700 1,350 1,400 75 1,200 1,000 900 940 3,200 16,550 22,025 18,000 8,000 3,400 1,620 1,300 1,300 80 1,100 980 850 940 2,600 15,580 21,400 16,700 7,488 3,200 1,600 1,300 1,200 85 1,100 950 800 900 2,200 14,400 20,900 15,850 7,070 3,000 1,600 1,200 1,100 90 1,000 900 770 850 2,100 13,500 19,900 14,000 6,690 2,800 1,500 1,100 1,000 95 950 820 750 780 1,500 12,000 18,105 12,800 5,800 2,395 1,400 1,000 900 96 950 820 730 750 1,400 11,636 18,000 12,000 5,506 2,176 1,400 1,000 900 97 950 820 730 750 1,400 11,154 17,600 11,000 5,255 2,000 1,400 1,000 850 98 920 820 690 650 1,300 10,636 17,162 8,380 5,000 2,000 1,400 1,000 800 99 920 800 690 650 1,200 10,000 16,886 7,500 4,550 1,900 1,300 954 750 100 920 800 690 650 1,100 8,580 14,400 7,500 4,150 1,700 1,100 900 650 ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 21 of 41 06/01/2011 Figure 7: Flow Frequency Curve for the Chulitna River at Talkeetna Figure 8: Flow Duration Curve for the Chulitna River at Talkeetna 0 5,000 10,000 15,000 20,000 25,000 30,000 35,000 40,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov DecDaily Flow (cfs)5% Exceedance 10% Exceedance 25% Exceedance 50% Exceedance 90% Exeedance Based on Historic Recorded Daily Flows in the Chulitna River nearTalkeetna - USGS Gage 15292400 0 5,000 10,000 15,000 20,000 25,000 30,000 35,000 40,000 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%Daily Flow (cfs)Percent of Time Flow is Equaled or Exceeded Based on Historic Recorded Daily Flowsin the Chulitna River near Talkeetna - USGS Gage 15292400 ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 22 of 41 06/01/2011 Table 21: Flow (cfs) Frequency at USGS Gage 15292780 – Susitna River at Sunshine % of Time Flow is Exceeded Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Annual (all months) 0 6,800 5,100 4,600 7,800 85,400 93,000 150,000 126,000 91,300 43,300 12,800 6,800 150,000 1 6,692 5,060 4,600 7,004 78,720 83,732 131,900 117,460 82,569 36,344 12,702 6,584 97,812 2 6,384 5,000 4,600 6,212 70,470 79,988 123,400 115,520 75,422 32,612 12,208 5,800 89,180 3 6,076 5,000 4,600 5,800 60,745 78,789 101,900 106,280 72,371 30,980 11,330 5,800 82,168 4 5,768 4,940 4,600 5,608 54,600 76,276 99,204 103,360 69,600 30,276 9,456 5,800 76,500 5 5,530 4,900 4,600 5,400 49,825 74,055 98,560 99,580 69,085 28,680 9,310 5,800 73,600 10 5,000 4,600 4,400 4,910 46,150 71,250 92,600 85,240 56,820 25,040 8,500 5,600 63,480 15 5,000 4,600 4,400 4,600 43,000 70,000 86,500 81,410 47,395 22,090 8,130 5,600 56,600 20 4,820 4,600 4,160 4,420 41,200 67,700 80,000 74,140 42,500 20,920 7,800 5,500 50,560 25 4,800 4,600 4,000 4,400 40,150 66,475 74,600 69,850 40,450 19,100 7,400 5,500 44,700 30 4,800 4,600 3,900 4,400 38,150 64,800 70,400 65,200 37,720 18,600 7,200 5,480 38,700 35 4,700 4,500 3,710 4,400 35,800 62,505 66,020 62,010 36,240 18,000 7,000 5,400 32,000 40 4,600 4,400 3,540 4,200 34,000 60,440 64,000 60,200 34,740 17,000 6,700 5,200 21,620 45 4,600 4,200 3,500 4,000 32,400 57,245 61,850 57,910 33,895 16,500 6,600 5,000 15,500 50 4,600 3,800 3,500 3,900 30,000 54,700 60,000 56,400 32,850 15,700 6,400 4,800 8,920 55 4,500 3,600 3,300 3,900 25,000 53,055 58,660 55,230 31,420 15,000 6,200 4,730 6,600 60 4,260 3,600 3,160 3,700 21,000 51,960 57,860 53,620 29,000 14,760 6,200 4,700 5,600 65 3,800 3,500 3,000 3,500 18,000 50,065 56,100 52,490 27,320 13,870 6,000 4,600 5,000 70 3,700 3,500 2,900 3,300 15,100 47,970 55,240 49,160 25,970 12,920 5,800 4,420 4,600 75 3,600 3,500 2,900 3,300 12,350 46,575 54,400 47,900 25,000 11,800 5,800 4,300 4,500 80 3,500 3,400 2,900 3,200 9,800 45,120 52,380 46,400 22,940 10,920 5,600 4,100 4,100 85 3,500 3,300 2,800 3,100 8,000 44,125 50,040 43,100 21,350 9,812 5,600 4,000 3,700 90 3,500 3,000 2,700 2,790 6,700 41,890 48,300 39,000 20,360 8,952 5,400 4,000 3,500 95 3,500 2,800 2,700 2,600 5,850 39,370 46,540 37,600 19,000 8,400 5,090 3,800 3,100 96 3,500 2,760 2,700 2,600 5,680 37,876 46,148 37,432 18,300 8,232 5,000 3,800 2,900 97 3,500 2,700 2,700 2,600 5,400 37,022 45,468 36,920 18,141 8,200 5,000 3,600 2,900 98 3,500 2,700 2,700 2,600 5,140 33,916 44,048 36,300 17,996 8,016 5,000 3,600 2,700 99 3,500 2,700 2,700 2,600 4,885 32,916 43,270 35,816 17,749 7,908 4,949 3,600 2,700 100 3,500 2,700 2,700 2,600 4,700 32,000 41,000 34,900 17,400 7,800 4,900 3,600 2,600 ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 23 of 41 06/01/2011 Figure 9: Susitna River Flow Frequency at Sunshine Figure 10: Susitna River Flow Duration at Sunshine 0 20,000 40,000 60,000 80,000 100,000 120,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov DecDaily Flow (cfs)5% Exceedance 10% Exceedance 25% Exceedance 50% Exceedance 90% Exeedance Based on Historic Recorded Daily Flows in the Susitna River at Sunshine -USGS Gage 15292780 0 10,000 20,000 30,000 40,000 50,000 60,000 70,000 80,000 90,000 100,000 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%Daily Flow (cfs)Percent of Time Flow is Equaled or Exceeded Based on Historic Recorded Daily Flowsin the Susitna River at Sunshine -USGS Gage 15292780 ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 24 of 41 06/01/2011 Table 22: Flow (cfs) Frequency at USGS Gage 15292780 – Susitna River at Susitna Station % of Time Flow is Exceeded Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Annual (all months) 0 12,000 10,000 10,000 53,000 175,000 195,000 226,000 228,000 208,000 293,000 48,200 19,000 293,000 1 11,500 10,000 10,000 43,610 147,290 185,610 200,430 216,430 170,000 122,640 42,572 17,060 178,440 2 11,000 9,900 9,620 35,440 139,580 175,220 190,860 196,860 159,220 95,472 34,974 16,000 163,000 3 11,000 9,792 9,500 29,660 134,290 170,000 188,290 185,000 149,660 89,616 30,000 15,000 154,000 4 11,000 9,700 9,500 24,000 128,720 166,440 183,440 175,440 138,880 83,096 28,000 15,000 148,000 5 11,000 9,600 9,500 22,000 124,000 163,100 178,150 171,300 133,050 77,400 26,000 14,000 142,000 10 10,500 9,500 9,500 16,000 108,600 151,000 162,300 146,60 0 110,100 62,920 23,000 13,000 126,000 15 10,000 9,100 9,000 13,075 98,490 143,000 155,000 139,000 100,150 55,880 21,000 12,000 115,000 20 10,000 8,900 8,600 12,000 90,060 137,000 151,000 134,000 93,240 49,580 20,000 12,000 104,000 25 9,500 8,500 7,400 10,500 85,000 133,000 145,000 129,000 89,075 45,000 19,000 12,000 91,600 30 9,000 8,200 7,300 10,000 80,580 129,000 141,000 124,000 84,830 42,060 18,000 11,000 77,020 35 9,000 8,000 7,000 9,500 75,000 126,000 137,000 120,000 80 ,935 39,920 17,000 11,000 60,440 40 8,500 8,000 7,000 8,880 70,040 123,000 133,000 116,000 77 ,560 36,900 16,000 11,000 44,000 45 8,500 8,000 7,000 8,000 68,640 121,000 130,000 113,000 74 ,000 35,000 15,000 10,000 30,000 50 8,400 7,500 7,000 7,500 65,100 118,000 126,000 108,000 69 ,900 34,000 14,750 9,500 20,000 55 8,200 7,500 6,920 7,200 60,000 115,000 122,650 105,650 66 ,700 33,000 14,000 9,460 14,000 60 8,000 7,500 6,600 7,000 56,980 112,000 120,000 103,000 63 ,100 31,000 14,000 9,000 11,000 65 8,000 7,500 6,500 7,000 52,000 109,650 117,000 99,895 59,500 30,000 13,000 8,800 10,000 70 7,600 7,000 6,500 6,500 46,600 105,000 115,000 95,510 56,000 28,000 13,000 8,600 9,100 75 7,500 6,800 6,500 6,500 40,100 101,750 112,000 92,625 53,775 26,000 12,000 8,000 8,500 80 7,500 6,800 6,200 6,500 34,000 98,540 109,000 88,000 50,380 24,000 11,000 7,500 7,600 85 7,000 6,500 6,000 6,000 27,000 93,900 106,000 84,400 47,285 22,000 10,000 7,400 7,200 90 6,800 6,500 5,600 6,000 20,000 88,980 102,000 80,000 41,930 19,800 10,000 7,000 6,800 95 6,400 6,000 5,400 5,400 12,000 78,880 96,140 73,700 37,00 0 16,400 8,645 6,000 6,400 96 6,400 6,000 5,400 5,400 11,000 74,912 94,928 70,712 34,64 8 16,000 8,380 6,000 6,000 97 6,400 5,600 5,200 5,400 10,000 71,053 93,942 68,271 32,00 0 15,000 8,000 6,000 6,000 98 6,000 5,600 5,000 5,000 9,500 67,934 92,300 65,098 29,780 15,000 7,500 6,000 6,000 99 6,000 5,200 5,000 5,000 8,500 66,739 89,671 61,128 22,000 13,000 7,000 6,000 5,400 100 6,000 5,200 5,000 5,000 7,500 61,800 82,500 55,000 19,00 0 11,000 6,500 6,000 5,000 ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 25 of 41 06/01/2011 Figure 11: Susitna River Flow Frequency at Susitna Station Figure 12: Susitna River Flow Duration at Susitna Station 0 20,000 40,000 60,000 80,000 100,000 120,000 140,000 160,000 180,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov DecDaily Flow (cfs)5% Exceedance 10% Exceedance 25% Exceedance 50% Exceedance 90% Exeedance Based on Estimated Flows in the Susitna River at Susitna Station - USGS Gage 15294350 0 20,000 40,000 60,000 80,000 100,000 120,000 140,000 160,000 180,000 200,000 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%Daily Flow (cfs)Percent of Time Flow is Equaled or Exceeded Based on Estimated Flows in the Susitna River at Susitna Station - USGS Gage 15294350 ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 26 of 41 06/01/2011 IV. Watana Dam Site Historical Flows The Watana dam site is located between USGS gage locations at Cantwell and Gold Creek. Because long term flow data are not available for the dam site, daily flow data from Cantwell and Gold Creek were used to create a modeled historical flow data set for Watana. The flow record at Gold Creek includes 57 years of daily data, and the flow record at Cantwell record includes 17 years. A 57 year modeled record was created for Watana through application of a monthly scaling factor, as described below. For each month in the 17 year period of concurrent Gold Creek and Cantwell gaging, a between-gage flow was calculated by subtracting the average monthly flow at Cantwell from the average monthly flow at Gold Creek. A 17 year average monthly flow record for the Watana dam site was modeled by multiplying the between-gage flow by the ratio of the between-gage drainage area that is upstream of the W atana site to the total between-gage drainage area, and subtracting the resulting value from the flow at Gold Creek. The estimated monthly average flow at the Watana dam site was divided by the average monthly flow at Gold Creek for each month in the 17 concurrent year record; this ratio was then averaged over all 17 years to create an average monthly scaling factor for estimating flow at Watana from flows at Gold Creek where concurrent individual monthly scaling factors were unavailable. A daily flow record for Watana was modeled by applying the monthly scaling factors to the 57 year daily flow record at Gold Creek. This modeled flow record was used to calculate the monthly flow averages, flow exceedances, and flow durations presented below. A separate technical memorandum will be prepared that estimates modified future reservoir inflows that could occur based on observed historical trends in streamflow and climate data. Estimated monthly average flow at Watana is between 78 and 86 percent of the flow at Gold Creek, with the higher percentages occurring during the summer snowmelt, and lower percentages occurring during the winter when precipitation is stored as snow in the upper watershed (Table 23). As shown on Table 24, the long-term average inflow at the Watana dam site is 8,116 cfs. Table 25 presents the flow frequency at the Watana dam site. Table 23: Monthly Scaling Factor Susitna River Flows at Gold Creek Adjusted to Watana Month Factor January 0.807 February 0.794 March 0.803 April 0.811 May 0.808 June 0.827 July 0.857 August 0.846 September 0.813 October 0.784 November 0.808 December 0.813 ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 27 of 41 06/01/2011 Table 24: Modeled Monthly Average Flow (cfs) at the Watana Dam Site Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Annual 1949 --- --- --- --- --- --- --- 20,518 12,726 4,970 2,086 1,170 --- 1950 829 625 583 706 9,297 16,203 19,360 16,821 6,750 3,019 1,050 894 6,394 1951 775 651 594 1,312 11,381 17,187 19,334 16,643 17,272 4,370 2,216 1,544 7,813 1952 1,291 794 707 746 4,377 26,760 22,607 17,701 11,775 6,434 2,825 1,382 8,150 1953 888 651 658 1,310 15,565 22,585 17,304 17,439 12,417 4,396 1,696 1,219 8,055 1954 1,049 794 626 1,002 13,958 20,874 17,441 22,084 10,506 4,213 2,229 1,662 8,089 1955 1,448 1,112 883 973 7,527 24,685 23,609 21,788 11,620 3,884 1,535 1,057 8,388 1956 791 770 755 771 14,265 27,562 26,633 20,755 14,905 4,555 2,464 1,741 9,718 1957 1,372 1,191 963 973 11,107 24,933 19,968 17,379 16,101 6,442 3,194 2,653 8,893 1958 1,586 1,038 922 1,243 10,420 21,246 19,600 19,072 6,139 3,774 1,737 1,230 7,383 1959 1,168 1,038 787 1,014 12,916 19,279 21,416 26,382 13,759 5,145 2,302 1,788 8,979 1960 1,489 1,153 961 1,054 12,746 12,839 19,686 19,960 16,678 6,114 2,423 2,190 8,163 1961 1,979 1,393 1,453 2,149 13,638 22,784 19,840 19,480 10,146 4,638 2,263 1,760 8,509 1962 1,609 1,257 1,177 1,457 11,333 36,017 23,444 19,887 12,746 5,560 2,509 1,709 9,927 1963 1,309 1,185 884 777 15,299 20,663 28,767 21,011 10,800 5,187 1,789 1,195 9,143 1964 852 782 575 609 3,579 42,842 20,083 14,048 7,524 4,759 2,368 1,070 8,263 1965 863 773 808 1,232 10,966 21,213 23,236 17,394 16,226 5,221 1,565 1,204 8,436 1966 1,060 985 985 1,338 7,094 25,940 16,153 17,391 9,214 3,270 1,202 1,122 7,172 1967 1,102 1,031 890 850 12,556 24,712 21,987 26,104 13,673 4,019 1,934 1,704 9,269 1968 1,618 1,560 1,560 1,577 12,827 25,704 22,083 14,148 7,164 3,135 1,355 754 7,829 1969 619 608 686 1,262 9,314 13,962 14,843 7,772 4,260 2,403 1,021 709 4,819 1970 636 602 624 986 9,536 14,399 18,410 16,264 7,224 3,768 2,496 1,687 6,435 1971 1,097 778 717 814 2,857 27,613 21,126 27,447 12,189 4,979 2,587 1,957 8,722 1972 1,671 1,491 1,366 1,305 15,973 27,429 19,820 17,510 10,956 3,786 1,820 1,191 8,734 1973 968 953 803 833 6,652 22,982 15,634 17,168 7,379 2,928 1,230 840 6,559 1974 705 617 581 804 13,069 14,773 16,105 13,724 9,961 2,933 1,373 1,303 6,372 1975 1,223 1,168 1,124 1,292 12,399 26,711 23,746 15,306 13,263 6,071 1,610 879 8,773 1976 786 754 723 1,114 10,194 20,155 16,225 16,753 5,595 3,039 2,141 1,953 6,661 1977 1,476 1,285 1,204 1,363 10,242 31,390 19,591 16,279 10,278 5,939 2,847 2,104 8,697 1978 1,637 1,325 1,289 1,380 9,653 15,749 18,007 13,868 6,999 3,849 2,048 1,366 6,471 1979 1,127 1,021 963 1,176 11,203 20,411 24,740 17,312 8,758 5,735 3,386 1,964 8,205 1980 1,411 1,164 1,124 1,355 9,741 23,399 26,741 18,005 10,995 6,632 3,044 1,790 8,836 1981 1,858 1,592 1,262 1,641 14,415 16,738 27,599 30,539 11,668 5,700 2,468 1,596 9,841 1982 1,380 1,103 971 1,196 10,876 21,443 20,443 13,203 13,977 5,154 2,132 1,893 7,849 1983 1,797 1,610 1,427 1,565 11,673 20,605 18,773 20,861 11,196 6,882 2,657 1,939 8,465 1984 1,782 1,741 1,697 1,613 10,831 22,908 20,707 17,421 7,347 4,257 2,384 1,799 7,917 1985 1,479 1,273 1,298 1,517 8,439 21,226 23,293 16,432 11,702 5,073 2,039 1,426 7,975 1986 1,207 1,131 1,038 1,162 9,734 17,817 20,424 14,596 10,457 9,947 2,787 1,589 7,707 1987 1,303 1,205 1,204 1,661 10,493 19,014 25,605 18,403 10,848 4,647 2,006 1,301 8,195 1988 1,260 1,191 1,204 1,287 14,031 24,569 22,007 16,533 11,206 6,020 2,434 1,626 8,661 1989 1,614 1,429 1,445 1,733 11,098 22,131 20,260 18,945 12,547 6,296 2,421 1,502 8,496 1990 1,424 1,350 1,487 3,447 20,703 27,942 20,140 20,078 21,557 5,409 1,977 1,788 10,650 1991 1,531 1,429 1,300 1,308 4,885 21,188 18,178 15,467 10,043 4,563 1,971 1,788 6,998 1992 1,586 1,429 1,500 1,703 4,930 19,130 21,879 17,895 8,270 3,435 2,208 1,657 7,175 1993 1,505 1,393 1,316 2,058 16,866 19,411 16,576 15,865 17,312 7,778 2,687 2,056 8,778 1994 1,661 1,418 1,225 2,612 11,801 25,702 17,955 15,721 7,609 3,554 2,246 1,705 7,800 1995 1,497 1,364 1,365 2,308 14,305 20,428 21,844 15,552 15,564 5,085 2,146 1,172 8,595 1996 1,007 942 883 1,095 5,342 12,987 13,715 14,494 8,465 ------ --- --- 2001 --- --- --- --- --- 25,628 18,889 18,437 8,424 3,797 2,122 1,542 --- 2002 1,249 1,128 1,046 1,079 9,297 13,682 15,548 20,121 13,214 8,590 4,357 2,105 7,666 2003 1,336 1,781 1,212 1,762 6,477 20,114 25,014 17,870 10,986 6,361 2,019 1,471 8,077 2004 1,187 1,013 868 2,214 19,039 20,940 17,270 14,993 5,247 2,589 1,400 1,309 7,390 2005 1,161 984 839 2,118 21,761 28,372 22,924 18,589 18,589 6,463 1,731 1,217 10,448 2006 1,130 1,103 1,093 1,245 12,706 19,254 19,823 26,069 10,002 8,151 2,536 1,885 8,818 2007 1,633 1,513 1,400 1,844 13,885 16,294 18,486 16,296 10,978 3,936 2,603 2,287 7,643 2008 1,486 1,066 1,092 1,355 9,580 17,460 18,872 16,694 11,807 4,337 1,250 1,057 7,213 2009 1,118 1,032 1,076 3,688 18,522 19,105 16,593 15,628 10,148 5,587 2,267 1,497 8,071 2010 1,185 1,072 1,048 1,498 15,840 16,550 23,575 16,990 12,864 --- --- --- --- Average 1,282 1,122 1,041 1,419 11,415 21,818 20,420 18,054 11,173 4,978 2,164 1,536 8,116 Maximum 1,979 1,781 1,697 3,688 21,761 42,842 28,767 30,539 21,557 9,947 4,357 2,653 10,650 Minimum 619 602 575 609 2,857 12,839 13,715 7,772 4,260 2,403 1,021 709 4,819 ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 28 of 41 06/01/2011 Table 25: Modeled Flow (cfs) Frequency at the Watana Dam Site The monthly flow frequency based on modeled daily flow at the Watana dam site is presented graphically in Figure 13. Figure 14 shows the annual flow duration curve for modeled flow at the Watana dam site, and Figures 15 and 16 show monthly flow duration curves for low and high flow months, respectively. % of Time Flow is Exceeded Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Annual (all months) 0 2,340 2,938 1,927 19,466 44,830 71,013 52,084 65,744 38,788 28,398 7,221 3,577 71,013 1 2,017 1,906 1,686 5,874 30,660 51,258 36,779 43,326 26,270 13,226 4,188 2,845 33,233 2 1,937 1,707 1,525 4,367 28,365 42,808 33,409 36,388 24,639 11,477 3,877 2,601 29,513 3 1,937 1,588 1,525 3,382 26,715 38,419 31,703 33,037 22,687 10,277 3,635 2,357 27,413 4 1,856 1,588 1,525 2,988 25,470 35,902 30,356 29,465 21,214 9,775 3,554 2,276 25,956 5 1,775 1,588 1,525 2,758 25,040 34,481 29,554 27,837 20,329 9,414 3,394 2,205 24,922 10 1,634 1,509 1,445 2,028 22,455 30,679 26,813 24,538 17,65 4 8,080 2,989 2,032 21,416 15 1,614 1,429 1,365 1,784 19,604 28,327 25,271 22,376 15,85 7 7,270 2,746 1,951 18,947 20 1,614 1,421 1,285 1,622 17,770 26,801 23,986 21,322 14,63 7 6,652 2,585 1,870 16,962 25 1,533 1,350 1,285 1,541 16,438 25,297 22,958 20,307 13,74 3 6,119 2,504 1,788 14,892 30 1,493 1,271 1,204 1,460 15,186 24,222 22,101 19,461 12,68 5 5,656 2,423 1,788 12,692 35 1,453 1,191 1,204 1,379 14,297 23,147 21,416 18,953 11,95 4 5,287 2,342 1,707 9,692 40 1,372 1,191 1,124 1,338 13,247 22,321 20,731 18,361 11,38 4 4,942 2,262 1,626 6,668 45 1,291 1,191 1,084 1,298 12,116 21,494 20,131 17,769 10,73 4 4,628 2,181 1,626 4,125 50 1,291 1,112 1,044 1,249 10,985 20,957 19,531 17,092 10,16 5 4,315 2,100 1,544 2,824 55 1,291 1,112 1,044 1,217 9,693 20,089 19,017 16,584 9,677 4 ,079 2,100 1,544 2,135 60 1,210 1,032 963 1,217 8,368 19,262 18,589 15,907 9,189 3,8 83 1,939 1,382 1,788 65 1,210 1,032 883 1,136 7,270 18,353 18,161 15,230 8,672 3,6 09 1,939 1,382 1,569 70 1,130 953 803 973 5,783 17,526 17,647 14,807 8,213 3,530 1,858 1,301 1,445 75 1,049 953 799 973 4,079 16,534 17,047 14,384 7,741 3,307 1,696 1,219 1,300 80 968 794 755 892 3,554 15,625 16,448 13,707 7,267 3,138 1,53 5 1,219 1,210 85 888 770 707 811 2,746 14,715 15,848 13,030 6,707 2,903 1,37 3 1,057 1,112 90 775 683 642 746 2,262 13,558 15,043 12,269 5,854 2,667 1,29 2 902 963 95 726 635 602 673 1,660 12,400 13,963 10,987 4,879 2,273 1,13 1 813 770 96 686 596 594 673 1,535 12,152 13,706 10,397 4,709 2,184 1,05 0 813 732 97 686 596 594 633 1,373 11,431 13,364 9,984 4,472 1,961 1,050 732 689 98 646 572 562 613 1,212 10,927 12,877 9,297 4,322 1,726 969 69 1 650 99 579 556 530 576 1,131 10,086 12,507 6,844 3,985 1,491 889 69 1 600 100 565 476 530 568 727 8,267 10,108 4,468 3,017 1,177 767 650 4 76 ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 29 of 41 06/01/2011 Figure 13: Modeled Susitna River Flow Frequency at Watana Figure 14: Modeled Susitna River Flow Duration at Watana 0 5,000 10,000 15,000 20,000 25,000 30,000 35,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov DecDaily Flow (cfs)5% Exceedance 10% Exceedance 25% Exceedance 50% Exceedance 90% Exeedance Based on Estimated Flowsin the Susitna River at Watana Modeled from Historic Recorded Daily Flows at Gold Creek 0 5,000 10,000 15,000 20,000 25,000 30,000 35,000 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%Daily Flow (cfs)Percent of Time Flow is Equaled or Exceeded Based on Estimated Flowsin the Susitna River at Watana Modeled from Historic Recorded Daily Flows at Gold Creek ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 30 of 41 06/01/2011 Figure 15: Modeled Susitna River Flow Duration at Watana for Low Flow Months Figure 16: Modeled Susitna River Flow Duration at Watana for High Flow Months 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%Daily Flow (cfs)Percent of Time Flow is Equaled or Exceeded Annual January February March April November December Based on Estimated Flows in the Susitna River at Watana Modeled from Historic Recorded Daily Flowsat Gold Creek 0 5,000 10,000 15,000 20,000 25,000 30,000 35,000 40,000 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%Daily Flow (cfs)Percent of Time Flow is Equaled or Exceeded Annual May June July August September October Based on Estimated Flowsin the Susitna River at Watana Modeled from Historic Recorded Daily Flows at Gold Creek ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 31 of 41 06/01/2011 V. Flood Frequency Peak annual flows have been recorded by the USGS at Cantwell, Gold Creek, Sunshine, and Susitna Station on the Susitna River, and on the Chulitna River near Talkeetna, as summarized in Tables 26, 28, 30, 32 and 33. Peak flow rates provided by the USGS include both average daily values and instantaneous peaks. Peak flows for return periods up to 10,000 years were estimated for the Susitna River at Cantwell and Gold Creek, and the Chulitna River at Talkeetna. The five year record of peak flows on the Susitna River at Sunshine is not sufficient for statistical evaluation, so peak flows at longer return periods were not estimated at this location. Peak flows were estimated for various return periods by fitting recorded peak flow data with a Log Pearson type III distribution according to methods in Bulletin 17B (IACW D, 1982). Estimated peak flows for the Susitna River at Cantwell and Gold Creek, the Chulitna River near Talkeetna, and the Susitna River at Susitna Station are presented in Tables 27, 29, 31, and 34. Table 26: Peak Annual Flows in the Susitna River at Cantwell The quality of the fit of the parameterized Log Pearson Type III distribution to the observed data is evaluated by plotting the data and the parameterized distribution together. A good fit is indicated by data points for observed annual peaks which are close to and randomly distributed above and below the computed Log Pearson Type III curve. The probability values assigned to each data point, called plotting positions, and the scale of the x-axis, are selected Date Peak Flow (cfs) June 23, 1961 30,400 June 15, 1962 46,800 July 18, 1963 32,000 June 08, 1964 51,200 July 13, 1965 26,000 June 06, 1966 27,000 August 14, 1967 38,800 May 22, 1968 25,000 July 15, 1969 19,300 August 01, 1970 20,500 August 10, 1971 55,000 June 17, 1972 44,700 July 29, 1980 28,500 August 14, 1981 30,900 June 21, 1982 24,100 June 04, 1983 25,800 June 16, 1984 33,400 July 03, 1985 28,200 ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 32 of 41 06/01/2011 so that the Log Pearson Type III distribution appears as a straight line when the skew value is zero. For evaluation of flood frequency on the Susitna River, Weibul plotting positions, as recommended in Bulletin 17B, were used to plot the data, and the x-axis scale was based on the standard normal deviate, z. The fitted distribution and resulting estimated peak flows at specified return periods are approximations. The ability to fit a distribution depends on the size and the variability within the sample. Confidence limits around the computed distribution curve provide a measure of the uncertainty for the predicted discharge at a specified exceedance probability. Figures 17 through 20 below show the fit Log Pearson Type III distribution as a solid line, 5% and 95% upper and lower confidence limits on the distribution as dashed lines, the observed annual peak flow data, and return periods for which peak flows were estimated in Tables 27, 29, 31, 34, and 35. Figure 17: Log Pearson Type III Flood Frequency Plot for the Susitna River at Cantwell 10,000 100,000 -2.6 -1.6 -0.6 0.4 1.4 2.4 3.4Peak Flow (cfs)Standard Normal Variable Computed Curve Observed Annual Peaks 5% and 95% Confidence Limit Curves Return Period (Years) 2 5 10 20 50 100 500 1,000 10,000 Log Pearson Type III Flood Frequency for the Susitna River at Cantwell ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 33 of 41 06/01/2011 Table 27: Calculated Flood Frequency for the Susitna River at Cantwell Table 28: Peak Annual Flows in the Susitna River at Gold Creek Return Period (Years) Flow (cfs) 2 30,300 5 39,700 10 46,600 25 56,000 50 63,600 100 71,700 200 80,200 500 91,900 1,000 101,000 10,000 133,000 Date Peak Flow (cfs)Date Peak Flow (cfs)Date Peak Flow (cfs) June 21, 1950 34,000 May 25, 1969 28,400 June 16, 1988 43,600 June 8, 1951 37,400 June 30, 1970 33,400 June 15, 1989 46,800 June 17, 1952 44,700 August 10, 1971 87,400 September 15, 1990 50,300 June 7, 1953 38,400 June 17, 1972 82,600 June 23, 1991 35,300 August 4, 1954 42,400 June 16, 1973 54,100 July 19, 1992 33,300 August 26, 1955 58,100 May 29, 1974 37,200 September 3, 1993 36,300 June 9, 1956 51,700 June 3, 1975 47,300 June 22, 1994 46,600 June 8, 1957 42,200 June 12, 1976 35,700 June 25, 1995 37,800 August 3, 1958 49,600 June 15, 1977 54,300 August 26, 1996 26,100 August 25, 1959 62,300 June 23, 1978 25,000 August 1, 2001 40,200 September 13, 1960 41,900 July 16, 1979 41,300 August 23, 2002 36,200 June 23, 1961 54,000 July 29, 1980 51,900 July 28, 2003 51,700 June 15, 1962 80,600 July 12, 1981 64,900 May 8, 2004 43,400 July 18, 1963 49,000 June 21, 1982 37,900 June 19, 2005 50,200 June 7, 1964 90,700 June 3, 1983 37,300 August 20, 2006 59,800 June 28, 1965 43,600 June 17, 1984 59,100 May 28, 2007 30,800 June 6, 1966 63,600 May 28, 1985 40,400 July 30, 2008 34,400 August 15, 1967 80,200 June 18, 1986 29,100 May 5, 2009 40,400 May 22, 1968 41,800 July 31, 1987 47,300 ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 34 of 41 06/01/2011 Figure 18: Log Pearson Type III Flood Frequency Plot for the Susitna River at Gold Creek Table 29: Calculated Flood Frequency for the Susitna River at Gold Creek 10,000 100,000 -2.6 -1.6 -0.6 0.4 1.4 2.4 3.4Peak Flow (cfs)Standard Normal Variable Computed Curve Observed Annual Peaks 5% and 95% Confidence Limit Curves Return Period (Years) 2 5 10 20 50 100 500 1,000 10,000 Log Pearson Type III Flood Frequency for the Susitna River at Gold Creek Return Period (Years) Flow (cfs) 2 44,000 5 57,200 10 66,600 25 79,500 50 89,800 100 101,000 200 112,000 500 127,000 1,000 139,000 10,000 180,000 ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 35 of 41 06/01/2011 Table 30: Peak Annual Flows in the Chulitna River at Talkeetna Two peak flow values, 75,900 cfs on July 20, 1967, and 100,000 cfs on August 19, 2006, were identified as high outliers using procedures in Bulletin 17B (IACWD, 1982). The August 19, 2006 flow was also flagged as estimated by the USGS. Both of these values were included in the peak flow analysis for this site. Date Date August 3, 1958 35,100 August 31, 1974 32,200 July 12, 1959 38,800 July 12, 1975 36,700 May 26, 1960 38,000 June 11, 1976 38,000 August 5, 1961 41,100 June, 1977 33,400 June 16, 1962 39,600 September 21, 1979 35,700 September 7, 1965 42,100 July 28, 1980 59,000 August 23, 1966 38,600 August 2, 1981 62,700 July 20, 1967 75,900 July 25, 1982 46,600 June 13, 1968 40,200 August 9, 1983 48,500 June 17, 1969 28,400 August 26, 1984 37,000 a August 2, 1970 36,400 July 2, 1985 40,700 August 11, 1971 50,800 July 14, 1986 36,300 July 10, 1972 34,700 October 11, 1986 57,700 1973 36,700 August 19, 2006 100,000 a a Discharge is an estimate. Peak Flow (cfs) Peak Flow (cfs) ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 36 of 41 06/01/2011 Figure 19: Log Pearson Type III Flood Frequency Plot for the Chulitna River at Talkeetna 10,000 100,000 1,000,000 -2.6 -1.6 -0.6 0.4 1.4 2.4 3.4Peak Flow (cfs)Standard Normal Variable Computed Curve Observed Annual Peaks 5% and 95% Confidence Limit Curves Return Period (Years) 2 5 10 20 50 100 500 1,000 10,000 Log Pearson Type III Flood Frequency for the Chulitna River near Talkeetna ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 37 of 41 06/01/2011 Table 31: Calculated Flood Frequency for the Chulitna River at Talkeetna Table 32: Peak Annual Flows in the Susitna River at Sunshine Due to the small sample size for peak flow at the Sunshine gage, a Log Pearson Type III distribution could not be fit. Discharge at longer return periods was therefore not calculated for this station. Return Period (Years) Flow (cfs) 2 40,600 5 52,200 10 61,400 25 74,800 50 86,200 100 98,800 200 113,000 500 133,000 1,000 149,000 10,000 211,000 Date Peak Flow (cfs) August 10, 1971 200,000 a July 11, 1981 150,000 July 25, 1982 125,000 August 10, 1983 103,000 August 26, 1984 114,000 July 2, 1985 100,000 October 11, 1986 185,000 a a Discharge is a historic peak ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 38 of 41 06/01/2011 Table 33: Peak Annual Flows in the Susitna River at Susitna Station Figure 20: Log Pearson Type III Flood Frequency Plot for the Susitna River at Susitna Station Date Peak Flow (cfs)Date Peak Flow (cfs) July 1, 1975 173,000 August 26, 1984 171,000 July 3, 1976 147,000 July 3, 1985 190,000 June 16, 1977 197,000 July 22, 1986 167,000 July 7, 1978 136,000 October 12, 1986 312,000 July 26, 1979 185,000 June 17, 1988 171,000 July 29, 1980 230,000 August 29, 1989 217,000 August 16, 1981 230,000 September 15, 1990 210,000 September 17, 1982 208,000 June 24, 1991 173,000 August 10, 1983 223,000 July 6, 1992 157,000 100,000 1,000,000 -2.6 -1.6 -0.6 0.4 1.4 2.4 3.4Peak Flow (cfs)Standard Normal Variable Computed Curve Observed Annual Peak 5% and 95% Confidence Limit Curves Return Period (Years) 2 5 10 20 50 100 500 1,000 10,000 Log Pearson Type III Flood Frequency for the Susitna River at Susitna Station ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 39 of 41 06/01/2011 Table 34: Calculated Flood Frequency for the Susitna River at Susitna Station Peak flows were estimated for return periods up to 10,000 years at the Watana dam site by transposing peak flow analysis results at Gold Creek to Watana according to the following equation: where A is the drainage area for each site. The exponent in this equation was selected as the value that minimized the percent error between the calculated peak flows at Cantwell presented in Table 27 and the estimated peak flows that resulted from transposing the calculated peak flows at Gold Creek to Cantwell. Table 35: Estimated Peak Annual Flows in the Susitna River at Watana Return Period (Years) Flow (cfs) 2 187,000 5 223,000 10 247,000 25 280,000 50 305,000 100 331,000 200 357,000 500 393,000 1,000 419,000 10,000 508,000 Return Period (Years) Peak Flow (cfs) 2 37,900 5 49,200 10 57,400 25 68,500 50 77,400 100 86,600 200 96,300 500 110,000 1,000 120,000 10,000 155,000 ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 40 of 41 06/01/2011 VI. Susitna Watershed Flow Distribution Future reservoir development and alteration of the current flow regime, including lower summer flows, higher winter flows, and dampening of peak flows, resulting from reservoir regulation may affect downstream habitat, and therefore is of interest. The potential magnitude of this impact can be preliminarily evaluated by comparing flow in the river at the Watana dam site to flow at downstream locations. Gages in the lower Susitna River watershed were used to determine the average monthly and annual flow distribution for the river. Figure 21 presents the annual average flow distribution, and Table 36 presents the average monthly flow at gaging stations, as a percent of the flow at Susitna Station, the most downstream gaging station. Flows at the Watana dam site account only for between 15 and 20 percent of the total flow in the river as measured at the Susitna Station USGS gage. Figure 21: Average Annual Flow Distribution for the Susitna River The percent contribution values presented in Table 36 were calculated from monthly averages for the four years of concurrent data, from 1982 to 1985, available for the Susitna River at Gold Creek, Sunshine, and Susitna Station, and for the Chulitna, Talkeetna, and Yentna Rivers. Local inflow between gaging locations in Figure 21 and Table 36 was calculated as the difference in flow between gaging stations. The drainage area contributing to local inflow was similarly assumed to be the difference in drainage area for gaged sites. 52% Susitna River at Sunshine 4% local inflow between Gold Creek and Sunshine 9% Talkeetna River Cook Inlet 17% Susitna River at Watana 21% Susitna River at Gold Creek local inflow between Watana and Gold Creek 4% 100% Susitna River at Susitna Station Chulitna River 18% YentnaRiver 41% 7% local inflow between Sunshine and Susitna Station Watana Dam site ALASKA RAILBELT LARGE HYDRO ENGINEERING SERVICES AEA11-022 TM-03-0003-060111v1.0 Page 41 of 41 06/01/2011 Table 36: Percent Contribution of Flow at Susitna River Watershed USGS Gage Stations to Flow at the Susitna Station USGS Gage VII. References U.S. Interagency Advisory Committee on Water Data [IACW D], 1982. Guidelines for determining flood flow frequency, Bulletin 17-B of the Hydrology Subcommittee: Reston, Virginia, U.S. Geological Survey, Office of Water Data Coordination. 183 p. Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Annual Susitna River at Watana 5,180 20 19 21 18 20 20 18 16 15 14 15 18 17 local inflow a 980 5 5 5 4 5 4 3 3 4 4 3 4 4 Susitna River at Gold Creek 6,160 24 24 26 22 25 24 21 19 19 18 18 22 21 Chulitna River near Talkeetna 2,570 20 16 17 14 13 17 21 20 17 16 16 19 18 Talkeetna River near Talkeetna 1,996 9 8 8 7 8 10 9 9 9 8 7 9 9 local inflow a 374 2 7 7 6 6 5 3 4 3 1 1 0 4 Susitna River at Sunshine 11,100 55 56 57 50 51 56 53 52 48 43 42 50 52 Yentna River near Susitna Station 6,180 38 38 40 45 42 44 44 44 37 34 32 35 41 local inflow a 2,120 6 6 3 6 6 1 3 4 15 23 26 15 7 Susitna River at Susitna Station 19,400 100 100 100 100 100 100 100 100 100 100 100 100 100 a Percent of flow attributed to local inflow is equal to the increase in flow between gaged locations on the Susitna River. Drainage Area (sq.mi.)