HomeMy WebLinkAboutWater quality modeling study 2012Alaska Resources Library & Information Services
Susitna-Watana Hydroelectric Project Document
ARLIS Uniform Cover Page
Title:
Water quality modeling study
SuWa 150
Author(s) – Personal:
Author(s) – Corporate:
Alaska Energy Authority
AEA-identified category, if specified:
Aquatic and fish resources study requests
AEA-identified series, if specified:
Series (ARLIS-assigned report number):
Susitna-Watana Hydroelectric Project document number 150
Existing numbers on document:
Published by:
[Anchorage] : Susitna-Watana Hydroelectric Project, [2012]
Date published:
5/15/12
Published for:
Date or date range of report:
Volume and/or Part numbers:
Final or Draft status, as indicated:
Document type:
Pagination:
7 p.
Related work(s):
Pages added/changed by ARLIS:
Notes:
All reports in the Susitna-Watana Hydroelectric Project Document series include an ARLIS-
produced cover page and an ARLIS-assigned number for uniformity and citability. All reports
are posted online at http://www.arlis.org/resources/susitna-watana/
Susitna-Watana Hydroelectric Project FERC # 14241 Alaska Energy Authority
Water Quality Modeling Study Request 5/15/12 Page 1
1.1. Water Quality Modeling Study
1.2. Requestor of Proposed Study
AEA anticipates resource agencies will request this study.
1.3. Responses to Study Request Criteria (18 CFR 5.9(b))
1.3.1. Describe the goals and objectives of the study proposal and the information to be
obtained
The collective goal of the water quality studies is to assess the effects of the proposed Project
on water quality in the Susitna River basin and to identify and develop protection, mitigation,
and enhancement measures that can be implemented to minimize these effects.
The objectives of the Water Quality Modeling Study are as follows:
• Build upon and use, as appropriate, the historical water quality modeling results/data for
the Project.
• Evaluate the 1980s water temperature model results and determine the applicability of
the past results to the currently proposed Project.
• Identify appropriate reservoir and river water temperature models.
• Model expected water quality conditions in the proposed Watana Reservoir, including
(but not necessarily limited to) temperature, dissolved oxygen (DO), suspended
sediment and turbidity, chlorophyll a, nutrients, metals, and ice formation and breakup
(unless a separate ice dynamics model is used).
• Model expected water quality conditions in the Susitna River from the proposed Watana
Dam downstream, including (but not necessarily limited to) temperature, suspended
sediment and turbidity, and ice processes (in coordination with the Ice Processes Study).
1.3.2. If applicable, explain the relevant resource management goals of the agencies and
Alaska Native groups with jurisdiction over the resource to be studied
To be completed by requesting organization.
1.3.3. If the requester is not a resource agency, explain any relevant public interest
considerations in regard to the proposed study
Fisheries resources are owned by the State of Alaska, and the Project could potentially affect
these public interest resources by affecting water quality.
1.3.4. Describe existing information concerning the subject of the study proposal, and
the need for additional information
Historical water quality data available for the study area include water temperature data
collected during the 1980s. Some of these data will be evaluated as part of the 2012 Water
Temperature Modeling Results and Data Collection study in an effort to determine what data will
be most appropriate to use for the 2013 - 2014 water quality studies.
Susitna-Watana Hydroelectric Project FERC # 14241 Alaska Energy Authority
Water Quality Modeling Study Request 5/15/12 Page 2
A data gap analysis was conducted for water quality and sediment transport in 2011 (URS et al.
2011). A detailed summary of results of the analysis is included in the data gap analysis report
(URS, 2011). A few of the broader conclusions about water quality conditions based on existing
data have been summarized in the Pre-Application Document (PAD) (AEA 2011).
Several conclusions from the data gap analysis were developed and used to identify future
studies needed to develop the riverine and reservoir water quality models and to eventually
predict pre-Project water quality conditions throughout the drainage. These are as follows:
• Lower Susitna River from Cook Inlet to the confluence of the Susitna, Chulitna, and
Talkeetna rivers (River Mile [RM] 0-99).
o Large amounts of data were collected in this reach during the 1980s. Very little data
are available that describe current water quality conditions.
o Metals data are not available for the mouth of Chulitna River. The influence of major
tributaries (Chulitna and Talkeetna rivers) on water quality conditions is unknown.
There are no monitoring stations in receiving water at these mainstem locations.
o Metals data are not available for the Skwentna or Yentna rivers.
o Continuous temperature data are not available for the mainstem and sloughs
potentially used for spawning and rearing habitat.
• Middle Susitna River and tributaries from the confluence of the Susitna, Chulitna, and
Talkeetna rivers to the mouth of Devils Canyon (RM 99-150).
o Sources for metals detected at high concentrations in the Susitna River mainstem (1
location). Improvements to sampling would include consideration for increasing
spatial coverage of sampling points to provide adequate representation of conditions.
o Current data reflect large spatial data gaps between the upper river and the mid- to
lower portion of the river.
o Continuous temperature data are not available for the mainstem, tributaries, and
sloughs potentially used for spawning and rearing.
• Middle Susitna River from Devils Canyon to the proposed Watana Dam site (RM 150-
184).
o Temperature data are not available above and below most tributaries on the
mainstem Susitna River.
o Overall, very limited surface water data are available for this reach.
o Metals monitoring data do not exist or are limited.
o Analysis of sediments for metals immediately below the proposed Project; sediments
may become transportable once the Project begins operation.
o Monitoring of mainstem and sloughs (ambient conditions and metals) needed for
determining bioaccumulation potential of fishes.
• Upper Susitna River including headwaters and tributaries above the proposed Watana
Dam site (RM 184-313).
Susitna-Watana Hydroelectric Project FERC # 14241 Alaska Energy Authority
Water Quality Modeling Study Request 5/15/12 Page 3
o Surface water and sediment analysis for metals not available for mainstem, only for
one tributary.
o Information on concentrations of metals in media and current water quality conditions
is needed to predict if toxics can be released in a reservoir environment.
o Continuous temperature data are not available for the mainstem, tributaries, and
sloughs potentially used for spawning and rearing.
1.3.5. Explain any nexus between project operations and effects (direct, indirect, and/or
cumulative) on the resource to be studied, and how the study results would
inform the development of license requirements
This study addresses some aspects of the following issues identified in the PAD (AEA 2011), for
which existing information appears to be insufficient:
“WQ3: Water Quality Modeling Study” - Addresses potential effect of Project operations
on temperature, turbidity, total dissolved/suspended solids, dissolved oxygen, pH,
metals, and chemical/nutrient characteristics of the mainstem river downstream from the
proposed Watana Dam Site (RM 184).
The Project's operations will modify the flow and water temperature regimes in the Susitna River
downstream of the proposed reservoir. Reservoir operation and storage levels will affect water
temperature in the reservoir and influence outflow water temperatures. Alteration of the baseline
water temperature regime of the Susitna River is expected to modify baseline river ice
conditions (which may affect channel morphology and riparian vegetation) and the suitability
and productivity of aquatic habitats.
The results of the 2013–2014 water quality studies will be used as a basis to assess the effects
of the proposed Project on water quality in the Susitna River basin and to identify and develop
any necessary protection, mitigation, and enhancement measures related to water quality
(including temperature), ice formation, and aquatic habitat in the reservoir and in Project-
affected river reaches downstream of the dam.
1.3.6. Explain how any proposed study methodology (including any preferred data
collection and analysis techniques, or objectively quantified information, and a
schedule including appropriate field season(s) and the duration) is consistent with
generally accepted practice in the scientific community or, as appropriate,
considers relevant tribal values and knowledge
1.3.6.1. Water Quality Modeling Study
To fully evaluate the effects of the proposed Project on conditions in the Susitna River,
predictive models are necessary.
A memo will be prepared that lists potential water quality models, identifies key considerations
for the selection of appropriate models, and recommends a modeling platform. In coordination
with stakeholders, a final modeling platform will be selected and implemented. It is anticipated
that a model with capabilities similar to the Environmental Fluid Dynamics Code (EFDC) will be
implemented for the reservoir modeling and river modeling.
Susitna-Watana Hydroelectric Project FERC # 14241 Alaska Energy Authority
Water Quality Modeling Study Request 5/15/12 Page 4
Reservoir modeling will focus on the length of the river from the expected upstream extent of
reservoir inundation to the proposed dam location. It will involve first running the initial reservoir
condition. This initial condition represents conditions in the absence of the dam. Subsequently,
the model will simulate the proposed reservoir condition, i.e., with the dam in place.
Downstream of the proposed dam location a river model will be developed to evaluate the
downstream effects of the proposed Project. The river model will be capable of representing
conditions in both the absence and presence of the dam. The downstream spatial extent of this
model is yet to be determined, but it likely will extend to shortly downstream of the confluence of
the Susitna, Talkeetna, and Chulitna rivers (e.g., Sunshine USGS Gage). If water quality
modeling indicates that water quality effects extend into the lower river downstream of the initial
modeling effort, then, as appropriate, water quality modeling will extend farther downstream.
This would require additional channel topography and flow data at select locations to develop a
model for predicting water quality conditions under various Project operation scenarios.
Several factors will be used to select a water quality model, which include the following:
• The model and code are easily accessible and are part of the public domain.
• The model is commonly used and accepted by United States Environmental Protection
Agency and other public regulatory agencies.
• The model will be available for current and future use and remain available for the life of
the Project and beyond (including upgraded versions).
1.3.6.2. Reservoir
A multi-dimensional model will be used to address the spatial and temporal variability of
hydrodynamics, temperature, and water quality processes within the reservoir. The model will
be able to simulate flow circulation in the reservoir both horizontally and vertically, represent the
initiation and completion of temperature stratification due to seasonal cycles, and represent the
impact of different flow regimes and dam operations on internal temperature dynamics. In
addition to hydrodynamics and temperature, the model will be able to simulate key water quality
processes including the fate and transport of organic and inorganic nutrients, nutrient-algae-
temperature interactions, total suspended solids (TSS), turbidity, and metals.
To develop the dynamic reservoir model, the following data need to be collected:
• Bathymetry information for the current river channel.
• Topographic information to represent the proposed reservoir.
• Upstream incoming flow rate (volumetric) at a daily frequency, inflow temperature (daily
or hourly), inflow concentrations of dissolved oxygen (DO) (daily or hourly, Sonde data),
chlorophyll a (bi-weekly), ammonia-N (bi-weekly), nitrate/nitrite (bi-weekly), total nitrogen
(TN) (bi-weekly), dissolved total nitrogen (DTN) (bi-weekly), orthophosphate (PO4) (bi-
weekly), dissolved PO4 (DPO4) (bi-weekly), total phosphorous (TP) (bi-weekly),
dissolved TP (bi-weekly), total organic carbon (TOC), dissolved organic carbon (DOC),
turbidity (continuous at USGS sites and bi-weekly at additional locations required for
calibrating the model), TSS (bi-weekly), and metals.
Susitna-Watana Hydroelectric Project FERC # 14241 Alaska Energy Authority
Water Quality Modeling Study Request 5/15/12 Page 5
• Ice data (particularly the time period associated with ice cover).
• Major lateral incoming tributary flow rates (volumetric) at a daily frequency, inflow
temperature (daily or hourly), inflow water quality in concentrations, and ice data (as
noted above).
• Atmospheric boundary conditions near the reservoir area, including wind velocity and
direction, air temperature, relative humidity, incident solar radiation, cloud cover, and
precipitation data.
• Any information associated with groundwater impacts (e.g., key locations, estimated flow
rate, temperature, DO, and nutrient concentrations).
Initial River Conditions
The model will first be run to represent conditions in the absence of the dam. This will provide a
starting point for comparison of dam impacts. Existing data for the river will be used for
calibration and validation of the model. Key calibration data include:
• Flow.
• Temperature.
• TP, TN, NH4, PO4, NO3, TOC, and DO.
• TSS, turbidity, and metals.
Proposed Reservoir Condition
The model will then be configured to represent the presence of the dam and the reservoir.
Configuration of this model will be dependent on engineering specifications for the dam and the
inundated area. No monitoring data will initially be available for this configuration (given that the
dam and reservoir do not yet exist); therefore, model parameter values from other
representative modeling studies will be considered. A key consideration for reservoir modeling
is ice dynamics. A description of ice processes from concurrent studies will be input to the
reservoir model to account for the influence on temperature and other water quality parameters
(e.g., pH, DO). The reservoir model will incorporate ice-associated model algorithms.
A series of scenarios will be run using the reservoir model to evaluate various management
decisions associated with the proposed Project. The modeling will be conducted during summer
and winter months to predict how Project operations affect water quality conditions. Modeling
during winter months will inform the changes expected to occur in ice processes.
1.3.6.3. River Downstream of Reservoir
A river model will be developed to evaluate the downstream effects of the proposed Project.
The river model will be capable of representing conditions in both the absence and presence of
the dam. It is anticipated that the same model platform used for the reservoir model will be
implemented for the river model (at a minimum the two models will be tightly coupled). Flow,
Susitna-Watana Hydroelectric Project FERC # 14241 Alaska Energy Authority
Water Quality Modeling Study Request 5/15/12 Page 6
temperature, TSS, DO, nutrients, turbidity (continuous at USGS sites & bi-weekly at additional
locations required for calibrating the model), and chlorophyll a output from the reservoir model
will be directly fed into the downstream river model. This will enable the downstream impacts of
the proposed Project on hydrodynamic, temperature, and water quality conditions to be directly
evaluated.
The river model will be calibrated and validated using available data concurrently with the initial
reservoir condition model (representing absence of the dam). Output from the models will be
used directly in other studies (e.g., Ice Processes, Productivity, and Instream Flow studies).
The model will be calibrated to simulate water quality conditions for load following analysis.
Organic carbon content from inflow sources will be used to correlate with mercury
concentrations determined from the Water Quality Baseline Monitoring study and integrate with
hypotheses from the toxics model that predict the potential for methylation of mercury in riverine
and reservoir habitats.
Water temperature modeling and routing of fluctuating flows immediately prior to and during ice
cover may be conducted with a separate thermodynamics-based ice processes model (e.g.,
CRISSP 1D).
1.3.6.4. EFDC and Other Candidate Model Evaluation
As noted above, EFDC, or a similar model, is a potential candidate for the modeling platform.
Candidate models will be capable of simulating both rivers and reservoirs. Each must be a
multi-dimensional dynamic model that includes hydrodynamics, water temperature, water
quality, and sediment transport modules. The model will be configured for the reservoir and
internally coupled with the downstream river model. This will form a holistic modeling
framework, which can accurately simulate changes in the hydrodynamic, temperature, and
water quality regime within the reservoir and downstream. A model for use in this study should
feature an advanced turbulence closure scheme to represent vertical mixing in reservoirs and
be able to predict future conditions. Thus, it will be capable of representing the temperature
regime within the reservoir without resorting to arbitrary assumptions about vertical mixing
coefficients.
The candidate model will have the ability to simulate an entire suite of water quality parameters.
The water quality model will have the capacity for internal coupling with the hydrodynamic and
temperature modeling processes. The model will be configured to simulate the impact of the
proposed Project on temperature as well as DO, nutrients, algae, turbidity, TSS, and other key
water quality features both within the reservoir and for the river downstream of the Project. This
avoids the added complexity associated with transferring information among multiple models
and increases the efficiency of model application.
1.3.7. Level of Effort and Cost
The cost and level of effort will be refined during the final study design. At this time, it is
anticipated to be as follows:
• Planning ($50k)
• Model calibration/development ($400k)
• Workgroup Involvement ($150K)
• Model results/scenarios ($350k)
• Reporting ($200k)
Susitna-Watana Hydroelectric Project FERC # 14241 Alaska Energy Authority
Water Quality Modeling Study Request 5/15/12 Page 7
1.3.8. Literature Cited
ADEC. 2005. Water Quality Assessment and Monitoring Program. Alaska Department of
Environmental Conservation: Division of Water. Juneau, Alaska. 58p.
URS. 2011. AEA Susitna Water Quality and Sediment Transport Data Gap Analysis Report.
Prepared by Tetra Tech, URS, and Arctic Hydrologic Consultants. Anchorage, Alaska.
62p.+Appendixes.