HomeMy WebLinkAboutWildlife habitat evaluation 2012Alaska Resources Library & Information Services
Susitna-Watana Hydroelectric Project Document
ARLIS Uniform Cover Page
Title:
Wildlife habitat evaluation
SuWa 156
Author(s) – Personal:
Author(s) – Corporate:
Alaska Energy Authority
AEA-identified category, if specified:
Botanical resources study requests
AEA-identified series, if specified:
Series (ARLIS-assigned report number):
Susitna-Watana Hydroelectric Project document number 156
Existing numbers on document:
Published by:
[Anchorage] : Susitna-Watana Hydroelectric Project, [2012]
Date published:
5/16/2012
Published for:
Date or date range of report:
Volume and/or Part numbers:
Final or Draft status, as indicated:
Document type:
Pagination:
4 p.
Related work(s):
Pages added/changed by ARLIS:
Notes:
All reports in the Susitna-Watana Hydroelectric Project Document series include an ARLIS-
produced cover page and an ARLIS-assigned number for uniformity and citability. All reports
are posted online at http://www.arlis.org/resources/susitna-watana/
Susitna–Watana Hydroelectric Project, FERC # 14241 Alaska Energy Authority
Wildlife Habitat Evaluation Study Request, 5/16/2012 Page 1
1.1. Wildlife Habitat Evaluation
1.2. Requester of proposed study
AEA anticipates a resource agency will request this study.
1.3. Responses to study request criteria (18 CFR 5.9(b))
1.3.1. Describe the goals and objectives of each study proposal and the information
to be obtained.
The overall goals of the wildlife habitat evaluation are:
1) to define habitat associations for birds and mammals that are of management or
conservation concern to federal and state management agencies that will review the
environmental analyses for the proposed Susitna-Watana Hydroelectric Project
(Project); and
2) to categorize habitat associations using a system that facilitates the assessments of
impacts to habitats that are important to many different types of birds and mammals
within the Project area.
The habitat-association data to be developed in this study, along with the wildlife habitats that
will be mapped digitally in the vegetation and wildlife habitat mapping study, will allow
quantitative assessments of the impacts to wildlife habitats from development of the proposed
Project. The quantitative, Geographic Information System (GIS)-based assessment of impacts
on wildlife habitats will play an important role in the overall evaluations of impacts to wildlife
during the Federal Energy Regulatory Commission’s (FERC) National Environmental Policy Act
(NEPA) and licensing processes. The specific objectives of the habitat evaluation study are to
use wildlife survey data collected within the Project area in conjunction and coordination with
development of wildlife habitat map to categorize habitat use for each bird and mammal species
of concern into one of several classes of habitat-value for each of the mapped wildlife habitats.
1.3.2. If applicable, explain the relevant resource management goals of the agencies
and/or Alaska Native entities with jurisdiction over the resource to be studied.
[Please include any regulatory citations and references that will assist in
understanding the management goals.]
To be provided by the requesting agency, Alaska Native entity, or Indian tribe.Federal and state
management goals for birds and mammals are described in the various FERC study requests
for studies of birds and mammals for the proposed Project. Most of those management goals
have a habitat component, in which the conservation, maintenance, or improvement of habitat is
part of the overall management goal(s). The information developed will be necessary for
identification of critically important habitats and a coordinated evaluation of Project-related
habitat effects for the development of appropriate avoidance, minimization, and mitigation
measures.
1.3.3. If the requester is a not resource agency, explain any relevant public interest
considerations in regard to the proposed study.
To be provided by requesting entity other than resource agency or Native American requester.
As the license applicant, Alaska Energy Authority (AEA) assumes that this study will be
Susitna–Watana Hydroelectric Project, FERC # 14241 Alaska Energy Authority
Wildlife Habitat Evaluation Study Request, 5/16/2012 Page 2
requested by resource agencies or other stakeholders during the study plan development
process. The public is generally concerned about the loss of wildlife habitats, especially rare or
sensitive wildlife habitats in Alaska. This study will provide a coordinated assessment of the
potential loss and alteration of wildlife habitats due to construction and operation of the
proposed Project.
1.3.4. Describe existing information concerning the subject of the study proposal,
and the need for additional information.
Wildlife habitat evaluations were conducted for the Susitna River basin in several studies in the
early 1980s for the original Alaska Power Authority Susitna Hydroelectric Project and for
another study effort in the lower portions of the drainage (AEA 2011). Those habitat evaluations
were based on vegetation cover types that were mapped within 16 km (10 mi) on each side of
the Susitna River between Gold Creek and the Maclaren River (TES 1982). That vegetation
mapping was conducted over 30 years ago and the subsequent habitat evaluations were
conducted at least 27 years ago.
Both the vegetation mapping and the habitat evaluation should be updated for the current
Project. The wildlife habitat evaluations completed in the early 1980s were based on vegetation
types, not wildlife habitat types. Wildlife habitat maps provide land cover classifications that are
better suited to evaluations of habitat use by birds and mammals than a vegetation map alone
through the incorporation of vegetation structure and landform information. Wildlife habitat use
can be influenced by the density of animals with a larger variety of habitats used when animal
densities are high. In addition, vegetation cover, structure, and landforms are likely to have
changed to some degree within the Project area due to landslides, erosion, thermokarst, fire,
forest succession, expansion/contraction/decadence of birch and aspen clones, and increases
in woody shrubs associated with increased summer temperatures. To provide current and
accurate information for assessing the impacts of habitat loss and alteration for wildlife during
the FERC licensing process, it will be necessary to update wildlife habitat evaluations proposed
Project, and that those habitat evaluations are based on current wildlife habitat maps for the
Susitna River basin.
1.3.5. Explain any nexus between project operations and effects (direct, indirect,
and/or cumulative) on the resource to be studied, and how the study results
would inform the development of license requirements.
Wildlife would be primarily affected by the loss and alteration of their preferred habitats, but
would also potentially be disturbance and displacement during Project construction and
operations. Habitat loss and alteration and disturbance/displacement effects are often treated as
indirect impacts. Direct impacts to birds and mammals could occur from mortality or injury
during collisions with transmission lines or vehicles and from the possible ingestion of
contaminants from accidental spills of petroleum products or other contaminants. Cumulative
impacts on birds and mammals could occur from extensive loss and alteration of habitats,
including fragmentation of habitats, in areas that have already undergone some development.
Regional cumulative effects, however, are unlikely to be extensive because the proposed
Project is located in a remote area where the primary developments include a few small lodge
operations and dispersed remote dwellings.
The results of the wildlife habitat evaluation study would provide current information on the
expected use of mapped wildlife habitats for birds and mammals of concerning the Project area
Susitna–Watana Hydroelectric Project, FERC # 14241 Alaska Energy Authority
Wildlife Habitat Evaluation Study Request, 5/16/2012 Page 3
and would, in coordination and conjunction with wildlife habitat mapping, facilitate quantitative
assessments of the loss and alteration of important wildlife habitats due to construction and
operation of the proposed Project. Current information on the habitat use of birds and mammals,
which would be derived in this study, will be critical to the accurate assessment of impacts to
birds and mammals during the FERC licensing process.
1.3.6. Explain how any proposed study methodology (including any preferred data
collection and analysis techniques, or objectively quantified information, and a
schedule including appropriate field season(s) and the duration) is consistent
with generally accepted practice in the scientific community or, as appropriate,
considers relevant tribal values and knowledge.
The proposed methods for the wildlife habitat evaluation study involve the use of current and
Project-specific survey data for birds and mammals in coordination and conjunction with the
preparation of a current wildlife habitat map for the Project area. This study would be an office-
based effort, performed after the wildlife habitat mapping for the Project area is completed.
The first task in the wildlife habitat evaluation study is the selection of a set of birds and
mammals of concern, which would be assessed for habitat impacts for the Project. The
procedure for determining which animals are included will be made with input from federal and
state management agencies during development of the formal 2013–2014 FERC study plans for
wildlife. Criteria will be established for the species-selection process, and it is likely that a
species will be selected if it meets one or more of the following criteria:
1) a federal or state-protected species;
2) a species of conservation concern as determined by various management agencies,
agency working groups, and non-governmental conservation organizations (FERC and
USFWS 2011);
3) a species of management concern for federal and/or state management agencies,
4) a sensitive species, which can reflect environmental effects through changes in
distribution and/or abundance; or
5) an ecologically important species (such as a prominent predator or prey species or one
with demonstrable ecosystem effects).
For each species of concern selected and for each wildlife habitat type mapped in the Project
area, a habitat-value ranking will be assessed. As with the species-selection process, this
procedure will be developed with input from federal and state management agencies during
preparation of the formal 2013–2014 FERC study plans for wildlife, but it is likely that a
simplified habitat-value categorization system would be used (e.g., negligible, low, moderate,
and high). The habitat-value rankings for various bird and mammal groups will be derived in
different ways depending on the level of Project-specific data that are available to assess
habitat use within each of the mapped wildlife habitat types. Observations of wildlife species will
be tagged to mapped habitats in a GIS and the data quality will be assessed for each species
and mapped habitat type (e.g., adequately sampled, undersampled, or not sampled).
Quantitative evaluations of the observations of the use of mapped habitats will be used
whenever possible to discern rankings among the habitat-value categories used, but in cases in
which the habitats in question were under sampled or not sampled, habitat-use information from
the scientific literature and/or from field experience with the species will be used to derive
habitat-value rankings. Specific habitat-use maps can be prepared for high-value game animals
Susitna–Watana Hydroelectric Project, FERC # 14241 Alaska Energy Authority
Wildlife Habitat Evaluation Study Request, 5/16/2012 Page 4
such as caribou, moose, and bears, that will illustrate specific use areas and periods in addition
to the identification of habitats that are important to a wide variety of wildlife..
1.3.7. Describe considerations of level of effort and cost, as applicable, and why any
proposed alternative studies would not be sufficient to meet the stated
information needs.
The wildlife habitat evaluation would be an office-based study only and likely could be
completed in several months, depending on the size of the area that will be mapped for wildlife
habitats, which will be determined in consultation with agency reviewers. The habitat evaluation
study would be conducted by up to 2 vegetation ecologists and 4 wildlife biologists with specific
expertise with various bird and mammal species groups. The cost for this office-based study is
expected to be relatively small in relation to the benefits that will be derived by facilitating a
coordinated, GIS-based assessment of Project impacts on bird and mammal habitats.
1.3.8. Literature Cited
AEA (Alaska Energy Authority). 2011. Pre-Application Document: Susitna-Watana Hydroelectric
Project FERC Project No. 14241. December 2011. Prepared for the Federal Energy
Regulatory Commission by the Alaska Energy Authority, Anchorage, Alaska.
FERC (Federal Energy Regulatory Commission) and USFWS (U.S. Fish and Wildlife Service).
2011. Memorandum of Understanding between the Federal Energy Regulatory Commission
and the U.S. Department of the Interior, United States Fish and Wildlife Service, Regarding
Implementation of Executive Order 13186, “Responsibilities of Federal Agencies to Protect
Migratory Birds.” March 2011. 13 pp.
TES (Terrestrial Environmental Specialists). 1982. Susitna Hydroelectric Project, Task 7—
Environmental studies, wildlife ecology: wildlife habitat-value analysis. Report prepared by
Terrestrial Environmental Specialists, Inc., Phoenix, NY, for Acres American, Inc., Buffalo,
NY. 100 pp.