HomeMy WebLinkAboutSmall mammal species composition and habitat 2012Alaska Resources Library & Information Services
Susitna-Watana Hydroelectric Project Document
ARLIS Uniform Cover Page
Title:
Small mammal species composition and habitat use
SuWa 171
Author(s) – Personal:
Author(s) – Corporate:
Alaska Energy Authority
AEA-identified category, if specified:
Wildlife resources study requests
AEA-identified series, if specified:
Series (ARLIS-assigned report number):
Susitna-Watana Hydroelectric Project document number 171
Existing numbers on document:
Published by:
[Anchorage] : Susitna-Watana Hydroelectric Project, [2012]
Date published:
5/16/2012
Published for:
Date or date range of report:
Volume and/or Part numbers:
Final or Draft status, as indicated:
Document type:
Pagination:
5 p.
Related work(s):
Pages added/changed by ARLIS:
Notes:
All reports in the Susitna-Watana Hydroelectric Project Document series include an ARLIS-
produced cover page and an ARLIS-assigned number for uniformity and citability. All reports
are posted online at http://www.arlis.org/resources/susitna-watana/
Susitna–Watana Hydroelectric Project, FERC # 14241 Alaska Energy Authority
Small Mammal Study Request, 5/16/2012 Page 1
1.1. Small Mammal Species Composition and Habitat Use
1.2. Requester of Proposed Study
AEA anticipates a resource agency will request this study.
1.3. Responses to Study Request Criteria (18 CFR 5.9(b))
1.3.1. Describe the goals and objectives of each study proposal and the information
to be obtained.
The goal of the small mammal study is to collect preconstruction baseline data on small
mammals in the Project area to enable habitat-based assessments of the impacts expected to
occur from development of the Project.
Three specific objectives have been identified for the small mammal study:
1) Describe the species composition and relative abundance of small mammals in the
Project area (reservoir impoundment zone, access route and transmission-line corridors,
and other areas that would be affected directly by Project infrastructure and activities);
2) Describe the habitat associations of small mammals within the Project area;
3) Estimate snowshoe hare population density in suitable habitats in the Project area and in
downstream riparian habitats.
1.3.2. If applicable, explain the relevant resource management goals of the agencies
and/or Alaska Native entities with jurisdiction over the resource to be studied.
[Please include any regulatory citations and references that will assist in
understanding the management goals.]
ADF&G is responsible for the management, protection, maintenance, and improvement of
Alaska’s fish and game resources in the interest of the economy and general well-being of the
state (AS 16.05.020). ADF&G manages subsistence and sport hunting and trapping small game
and furbearers on State lands (5 AAC 85), through regulations set by the Board of Game (AS
16.05.255). Snowshoe hares are managed by ADF&G as small game. In the Project area and
adjacent areas (Game Management Units [GMUs] 13, 14, 16, and 20), there are no limits and
no closed season for snowshoe hares. Squirrels, including red, ground, and flying squirrels are
managed by ADF&G as fur animals (with beaver, coyote, foxes, and lynx), although there
currently is no limit and no closed season. Other small mammals (shrews, mice, pikas) are
considered unclassified game animals by the ADF&G. There are no take limits or closed
seasons, but the hide or meat of pikas must be salvaged. No data on harvest or abundance are
collected by ADF&G for any small mammal species.
The Federal Subsistence Board, which comprises representatives from the U.S. Fish and
Wildlife Service, National Park Service, Bureau of Land Management, Bureau of Indian Affairs,
and U.S. Forest Service, oversees the Federal Subsistence Management Program (57 FR
22940; 36 CFR Parts 242.1–28; 50 CFR Parts 100.1–28), with responsibility for managing
subsistence resources on Federal public lands for rural residents of Alaska.
Susitna–Watana Hydroelectric Project, FERC # 14241 Alaska Energy Authority
Small Mammal Study Request, 5/16/2012 Page 2
1.3.3. If the requester is not a resource agency, explain any relevant public interest
considerations in regard to the proposed study.
Wildlife resources are owned by the State of Alaska, and the Project could potentially affect
these public interest resources.
1.3.4. Describe existing information concerning the subject of the study proposal,
and the need for additional information.
Small mammal species in the Susitna River basin include snowshoe hare, porcupine, hoary
marmot, arctic ground squirrel, red squirrel, collared pika, and several species each of voles,
mice, and shrews [little brown bats are the subject of a separate study request]. Species
composition, relative abundance, and habitat use by small mammals were studied for the
original Susitna Hydroelectric Project (SHP) in 1980 and 1981 along 49 trapline transects (using
both snap-traps and pitfall traps) located in a variety of different habitat types in the middle and
upper Susitna River basin (Kessel et al. 1982). The SHP study area for small mammals (Kessel
et al. 1982) extended from Sherman (near Gold Creek) on the west to the mouth of the
Maclaren River on the east and for approximately 16 km (10 miles) on each side of the Susitna
River; no surveys of small mammals were conducted downstream from Sherman.
Since completion of the original SHP studies, a new species of small mammal—the Alaska tiny
shrew—was recognized and described (Dokuchaev 1997, MacDonald and Cook 2009). The
earliest specimen known was trapped in 1982 near the upper Susitna River during the SHP
study. By 2007, the total number collected statewide had increased to 38 specimens from at
least 22 widely separated locations (Cook and MacDonald 2009), indicating the species was
more widespread than originally thought. Early information indicated it occurred primarily in
riparian habitats but, as trapping efforts expanded, it also was captured in scrub habitats. The
Alaska Natural Heritage Program classified the Alaska tiny shrew as “unrankable” globally (GU),
presumably because little information was available, and as “vulnerable” in the state (S3;
AKNHP 2011), probably due to restricted range and relatively few populations. The species was
included on BLM’s Alaska list of sensitive species (2010).
No recent reports on small mammal studies in the middle or upper Susitna basin are available.
Other studies in surrounding regions included species inventories in Denali National Park and
Preserve (Cook and MacDonald 2003) and on Fort Richardson near Anchorage (Peirce 2003),
and long-term population monitoring (1992–2005) of three species of voles was conducted in
Denali National Park and Preserve by Rexstad and Debevec (2006).
The SHP studies provided a thorough sampling of the small mammal populations in the project
area. Although 30 years have elapsed since those studies, it is unlikely that species distribution
patterns or habitat use have changed significantly in the interim. Because of the often cyclical
population fluctuations of small mammals and the lack of effective mitigation to offset population
losses in the impoundment zone, the wildlife data-gap analysis report (ABR 2011) questioned
whether additional studies are warranted for the Project. A current field survey focused on the
reservoir impoundment zone, access and transmission corridors, and associated areas of
infrastructure would provide useful information for evaluating the direct effects of habitat loss on
small mammals. Because of the ecological importance of the species as an herbivore and prey
animal for carnivores and raptors, current estimates of snowshoe hare population density
should be obtained in the same area, as well as in downstream riparian habitats.
Susitna–Watana Hydroelectric Project, FERC # 14241 Alaska Energy Authority
Small Mammal Study Request, 5/16/2012 Page 3
1.3.5. Explain any nexus between project operations and effects (direct, indirect,
and/or cumulative) on the resource to be studied, and how the study results
would inform the development of license requirements.
For small mammals, the Project will result in habitat loss and alteration, habitat fragmentation,
disturbance, and direct and indirect mortality due to development activities. The small mammal
study would provide baseline data for the Project area, including habitat use data for
development of habitat evaluation criteria. The study would provide data to assess the following
direct, indirect, and cumulative effects:
• Direct and indirect loss and alteration of wildlife habitats from Project construction and
operation;
• Potential physical and/or behavioral blockage and alteration of movements due to
reservoir water and ice conditions, access and transmission corridors, and new patterns
of human activities and related indirect effects, including habitat connectivity and genetic
isolation;
• Potential direct mortality due to Project-related fluctuations in water and ice conditions in
the reservoir and downstream river reaches;
• Potential direct, indirect, and cumulative impacts on predator and prey abundance and
distribution related to increased human activities and habitat changes resulting from
Project development;
• Potential direct behavioral impacts to wildlife, such as attraction or avoidance, resulting
from vehicular use, noise, and increased human presence associated with Project
construction or operation;
• Potential indirect behavioral impacts to wildlife, such as attraction or avoidance, resulting
from changes in hunting, vehicular use, noise, and increased human presence
associated with increased subsistence or recreational access that may be facilitated by
Project development;
• Potential direct mortality due to vehicle strikes, exposure to contaminants, attraction to
garbage and human activity, and protection of life and property; and
• Potential changes in wildlife mortality rates due to increased subsistence and sport
harvest facilitated by Project development.
The small mammal study would provide a basis for impact assessment; developing
anydeveloping any necessary protection, mitigation, and enhancement (PME) measures; and
developing resource management and monitoring plans.
1.3.6. Explain how any proposed study methodology (including any preferred data
collection and analysis techniques, or objectively quantified information, and a
schedule including appropriate field season(s) and the duration) is consistent
with generally accepted practice in the scientific community or, as appropriate,
considers relevant tribal values and knowledge.
In combination with the wildlife habitat mapping effort, the small mammal survey would provide
data with which to evaluate the potential impacts of the Project. As in the landbird and shorebird
study, sampling locations would be distributed across the landscape and allocated by habitat
type to ensure that all the prominent habitats are sampled. Sampling locations would be
allocated using a pseudo-stratified random plot allocation procedure, using aerial-photo
signatures as the sampling strata because a current and complete habitat map likely will not be
available by the time sampling would begin in 2013. Alternatively, the field survey could be
Susitna–Watana Hydroelectric Project, FERC # 14241 Alaska Energy Authority
Small Mammal Study Request, 5/16/2012 Page 4
postponed until 2014 to take advantage of the vegetation and habitat mapping that will have
advanced by that time.
Standard trapping methods for small mammals would be used (e.g., Jones et al. 1996),
including both pitfall traps and snap-traps for voles, lemmings, and shrews, and pellet group
counts for snowshoe hares (in combination with the hare sampling proposed for the separate
terrestrial furbearer study). Pitfall traps will be plastic, as opposed to metal, to improve trapping
success for the Alaska tiny shrew. Trapping data will include the relative abundance of each
species in each habitat, allowing a quantitative assessment of habitat loss and habitat
connectivity. Snowshoe hare pellet group counts also would be conducted in downstream
riparian habitats and would extend over 2 years to better characterize the current phase of the
dramatic population cycle exhibited by the species.
1.3.7. Describe considerations of level of effort and cost, as applicable, and why any
proposed alternative studies would not be sufficient to meet the stated
information needs.
Detailed estimates of effort have not yet been developed, but a single season of trapping effort,
consisting of 1 to 2 weeks of field trapping by two crews (two biologists each) in late summer
2013 or 2014 (when small mammal populations should have reached their highest seasonal
levels), would be adequate to satisfy the study objectives for most small mammals. The
exception would be the field survey of snowshoe hare density in the downstream riparian study
area, which would be conducted in both years. The study area would consist of the same area
covered by the vegetation mapping effort to provide a landscape context in which to evaluate
the study results. Snowshoe hare density estimation would extend downstream to the Chulitna
River confluence, and possibly could be combined with riparian habitat mapping.
At this writing, no alternative studies have been proposed specifically for small mammals,
although the terrestrial furbearer study request includes sampling to evaluate prey population
density (snowshoe hares and voles).
1.3.8. Literature Cited
ABR. 2011. Wildlife data-gap analysis for the proposed Susitna-Watana Hydroelectric Project.
Draft report, August 16, 2011, prepared for the Alaska Energy Authority by ABR, Inc.—
Environmental Research & Services, Fairbanks, Alaska. 114 pp.
AKNHP (Alaska Natural Heritage Program). 2011. Species tracking list (updated January 2011).
Alaska Natural Heritage Program, University of Alaska, Anchorage. 31 pp. Available online:
http://aknhp.uaa.alaska.edu/wp-content/uploads/2010/11/
All_Tracking_Lists_Combined1.pdf (accessed 12 August 2011)
BLM (Bureau of Land Management). 2010. BLM–Alaska sensitive animal and plant lists. Alaska
State Office, Anchorage.
Cook, J. A., and S. O. MacDonald. 2003. Mammal inventory of Alaska’s national parks and
preserves: Denali National Park and Preserve. 2002 annual report for National Park
Service, Alaska Region Survey and Inventory Program, Anchorage, by Idaho State
University, Pocatello. 24 pp.
Dokuchaev, N.E. 1997. A new species of shrew (Soricidae, Insectivora) from Alaska. Journal of
Mammalogy 78: 811–817.
Susitna–Watana Hydroelectric Project, FERC # 14241 Alaska Energy Authority
Small Mammal Study Request, 5/16/2012 Page 5
Jones, C., W. J. McShea, M. J. Conroy, and T. H. Kunz. 1996. Capturing mammals. Pages
115–155 in D. E. Wilson, F. R. Cole, J. D. Nichols, R. Rudran, and M. S. Foster, editors.
Measuring and Monitoring Biological Diversity: Standard Methods for Mammals.
Smithsonian institution Press, Washington, DC.
Kessel, B., S. O. MacDonald, D. D. Gibson, B. A. Cooper, and B. A. Anderson. 1982. Susitna
Hydroelectric Project environmental studies, Phase I final report—Subtask 7.11: Birds and
non-game mammals. Report by University of Alaska Museum, Fairbanks, and Terrestrial
Environmental Specialists, Inc., Phoenix, NY for Alaska Power Authority, Anchorage.
149 pp.
MacDonald, S. O., and J. A. Cook. 2009. Recent Mammals of Alaska. University of Alaska
Press, Fairbanks. 387 pp.
Peirce, K. N. 2003. A small mammal inventory on Fort Richardson, Alaska. Report by Center for
Environmental Management of Military Lands, Colorado State University, for U.S. Army
Environmental Resources Department, Fort Richardson, Alaska. 40 pp.
Rexstad, E., and E. Debevec. 2006. Dynamics of small mammal populations in the Rock Creek
watershed, Denali National Park and Preserve. Alaska Park Science 6: 69–72. Available
online: http://www.nps.gov/akso/AKParkScience/symposium2006/rexstad.pdf (accessed 10
August 2011)