HomeMy WebLinkAboutSalmon escapement section 9.7 2013Alaska Resources Library & Information Services
Susitna-Watana Hydroelectric Project Document
ARLIS Uniform Cover Page
Title:
Salmon escapement study, Study plan Section 9.7 : Final study plan
SuWa 200
Author(s) – Personal:
Author(s) – Corporate:
Alaska Energy Authority
AEA-identified category, if specified:
Final study plan
AEA-identified series, if specified:
Series (ARLIS-assigned report number):
Susitna-Watana Hydroelectric Project document number 200
Existing numbers on document:
Published by:
[Anchorage : Alaska Energy Authority, 2013]
Date published:
July 2013
Published for:
Date or date range of report:
Volume and/or Part numbers:
Study plan Section 9.7
Final or Draft status, as indicated:
Document type:
Pagination:
25 p.
Related work(s):
Pages added/changed by ARLIS:
Notes:
All reports in the Susitna-Watana Hydroelectric Project Document series include an ARLIS-
produced cover page and an ARLIS-assigned number for uniformity and citability. All reports
are posted online at http://www.arlis.org/resources/susitna-watana/
Susitna-Watana Hydroelectric Project
(FERC No. 14241)
Salmon Escapement Study
Study Plan Section 9.7
Final Study Plan
Alaska Energy Authority
July 2013
FINAL STUDY PLAN SALMON ESCAPEMENT STUDY 9.7
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.7-1 July 2013
9.7. Salmon Escapement Study
On December 14, 2012, Alaska Energy Authority (AEA) filed with the Federal Energy
Regulatory Commission (FERC or Commission) its Revised Study Plan (RSP), which included
58 individual study plans (AEA 2012). Included within the RSP was the Salmon Escapement
Study, Section 9.7. RSP Section 9.7 focuses on characterizing the current distribution,
abundance, habitat use, and migratory behavior of all species of adult anadromous salmon across
mainstem river habitats and select tributaries above the Three Rivers Confluence (i.e.,
confluence of the Susitna, Chulitna, and Talkeetna rivers).
On February 1, 2013, FERC staff issued its study determination (February 1 SPD) for 44 of the
58 studies, approving 31 studies as filed and 13 with modifications. RSP Section 9.7 was one of
the 13 approved with modifications. In its February 1 SPD, FERC recommended the following:
We recommend the study be modified to require AEA to extend the operation of its Curry Station
fishwheels at RM 120 through the entire month of September.
We recommend the study be modified to require AEA to include in the initial study report an
evaluation, based on site-specific data obtained during the 2013 study season, of the
feasibility of putting in a weir or sonar counting station at or near the dam site during the
2014 study season to provide an accurate count of any resident or anadromous fish that are
successfully able to migrate upstream through Devils Canyon into the project area.
On February 21, 2013, the National Marine Fisheries Service (NMFS) filed a notice of study
dispute pursuant to section 5.14(a) of the Commission’s regulations. This dispute included four
elements of RSP Study 9.7.
On April 3, 2013, a dispute resolution panel held the technical conference, which was attended
by representatives from NMFS, AEA, the Commission, and other licensing participants. On
April 12, 2013, the panel filed its findings with the Commission, and recommended no additional
modifications to RSP Section 9.7. On April 26, 2013, the Commission issued determination
requiring no changes in its earlier study plan determination.
In accordance with the February 1 SPD, AEA has adopted the modifications outlined in FERC’s
February 1 SPD.
9.7.1. General Description of the Proposed Study
Information from this Salmon Escapement Study will be used in combination with other studies
to assess potential effects of the proposed Project on fisheries resources. Construction and
operation of the Project will modify the flow, thermal, and sediment regimes of the Susitna
River, which may alter the composition and distribution of fish. This study will provide
information on the distribution and abundance of adult salmon in the Lower, Middle, and Upper
Susitna River. This work will be conducted through collaboration among the Alaska Energy
Authority (AEA), the Alaska Department of Fish and Game (ADF&G), and other licensing
participants. Information developed in this study may also be used to develop any necessary
protection, mitigation, or enhancement measures to address Project impacts to salmonid
resources.
FINAL STUDY PLAN SALMON ESCAPEMENT STUDY 9.7
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.7-2 July 2013
9.7.1.1 Study Goals
The primary goal of the study is to characterize the current distribution, abundance, habitat use,
and migratory behavior of all species of adult anadromous salmon across mainstem river habitats
and select tributaries above the Three Rivers Confluence (i.e., confluence of the Susitna,
Chulitna, and Talkeetna rivers). Sufficient information of this nature has been collected for
several species elsewhere in the Susitna watershed. However, for Chinook and coho salmon,
additional information would aid in assessing the potential impacts of the Project. Therefore, a
second goal of this study is to estimate the distribution, abundance, and migratory behavior of
adult Chinook throughout the entire Susitna River drainage, and the coho salmon distribution
and abundance in the Susitna River above the confluence of the Yentna River.
9.7.1.2 Study Objectives
1. Capture, radio-tag, and track adults of five species of Pacific salmon in the Middle and
Upper Susitna River in proportion to their abundance. Capture and tag Chinook, coho and
pink salmon in the Lower Susitna River.
2. Characterize the migration behavior and spawning locations of radio-tagged fish in the
Lower, Middle, and Upper Susitna River.
3. Characterize adult salmon migration behavior and timing within and above Devils
Canyon.
4. If shown to be an effective sampling method, and where feasible, use sonar to aid in
documenting salmon spawning locations in turbid water in 2013 and 2014.
5. Compare historical and current data on run timing, distribution, relative abundance, and
specific locations of spawning and holding salmon.
6. Generate counts of adult Chinook salmon spawning in the Susitna River and its
tributaries to estimate the proportions of fish with tags for populations in the watershed.
7. Collect tissue samples to support the Fish Genetic Baseline Study (Section 9.14).
8. Estimate the system-wide Chinook salmon escapement to the entire Susitna River, the
coho salmon escapement to the Susitna River above the its confluence with the Yentna
River, and the distribution of Chinook, coho, and pink salmon among tributaries of the
Susitna River (upstream of Yentna River confluence) in 2013 and 2014.
9.7.2 Existing Information and Need for Additional Information
Existing information includes fish spatial and temporal distribution and relative abundance
information from recent and early 1980s studies. The Aquatic Resources Data Gap Analysis
(ARDGA; AEA 2011a) and PAD (AEA 2011b) summarized existing information and identified
data gaps for adult and rearing salmon. The licensing effort of the 1980s APA Susitna
Hydroelectric Project generated a substantial body of literature, some of which will be
summarized and used to support the 2013–2014 data collection efforts. The adult salmon habitat
use studies conducted by ADF&G during the 1980s are summarized by Woodward-Clyde
Consultants and Entrix, Inc. (1985). In recent years, ADF&G has conducted adult salmon
(sockeye, coho, and chum) spawning distribution and abundance studies in the Susitna River
FINAL STUDY PLAN SALMON ESCAPEMENT STUDY 9.7
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.7-3 July 2013
(e.g., Merizon et al. 2010; Yanusz et al. 2011). In 2012, ADF&G expanded its scope to include
Chinook and pink salmon. Existing fish and aquatic resource information appears insufficient to
address the issues below that were identified in the PAD (AEA 2011b).
• F2: Potential effect of fluctuating reservoir surface elevations on fish access and
movement between the reservoir and its tributaries and habitats.
• F3: Potential effect of Watana Dam on fish movement.
• F4: Effect of Project operations on flow regimes, sediment transport, temperature, and
water quality that result in changes to seasonal availability and quality of aquatic habitats,
including primary and secondary productivity. The effect of Project-induced changes
include stream flow, stream ice processes, and channel morphology (streambed
coarsening) on anadromous fish spawning and incubation habitat availability and
suitability in the mainstem and side channels and sloughs in the Middle River above and
below Devils Canyon.
• F5: Potential effect of Project flow regime on anadromous fish migration above Devils
Canyon. Devils Canyon is a velocity barrier to most fish movement and changes in flows
can result in changes in the potential fish movement through this area (approximately
river mile [RM] 150).
• F6: Potential influence of the proposed Project flow regime and the associated response
of tributary mouths on fish movement between the mainstem and tributaries within the
Middle River reach.
• F7: Influence of Project-induced changes to mainstem water surface elevations July
through September on adult salmon access to upland sloughs, side sloughs, and side
channels.
• F8: Potential effect of Project-induced changes to stream temperatures, particularly in
winter, changing the distribution of fish communities, particularly invasive northern pike.
Susitna River Chinook and coho salmon stocks support important commercial, sport, and
subsistence fisheries in Northern Cook Inlet (NCI). The Susitna River currently supports the
fourth largest run of Chinook salmon in Alaska (Ivey et al. 2009). Chinook salmon escapements
in the Susitna drainage are monitored annually by ADF&G with single aerial (helicopter) or foot
surveys. These surveys provide an index of escapement rather than a complete census of the
escapement. These measurements provide a ranking of escapement magnitudes across years, but
alone these measurements provide little information on the total number of fish in the
escapement (Fair et al. 2010).
In 1985, ADF&G operated fishwheels at RM 22 and RM 82 in the Susitna River to estimate the
escapement of Chinook salmon to the Susitna River drainage. The Chinook salmon escapement
at Flathorn was estimated to be 113,931 fish (length greater than 400 millimeters [15.75 inches])
with a standard deviation of 77,931 (Thompson et al. 1986). This is the only drainage-wide
Chinook salmon escapement estimate for the Susitna River. A drainage-wide abundance
estimate of returning adult Chinook salmon using capture-recapture methods is most likely to
yield the most accurate and precise estimate of the abundance of spawning Chinook salmon.
FINAL STUDY PLAN SALMON ESCAPEMENT STUDY 9.7
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.7-4 July 2013
During the 1985 adult salmon investigation study, spawning ground surveys were conducted for
Chinook salmon in the Middle and Lower Susitna River. These observational surveys were
conducted by surveyors wearing polarized sunglasses looking for visual verification of mating
pairs, distinct redds, or the confirmed presence of eggs by intergravel sampling (Thompson et al.
1986). No spawning areas were observed in the sloughs or Middle River mainstem channel in
1985. The 1985 report does not mention if spawning areas were found in the Lower River
mainstem channel. This radio telemetry study would attempt to characterize any Chinook
salmon spawning in the mainstem Susitna River. ADF&G has successfully used this approach to
identify likely spawning areas for sockeye, coho, and chum salmon within the Susitna River
drainage (Yanusz et al. 2011; Merizon et al. 2010; Yanusz et al. 2007).
9.7.3 Study Area
The study area encompasses the Susitna River from Cook Inlet upstream to the Oshetna River, or
as far upstream as Chinook salmon are detected (Figure 9.7-1), with an emphasis on wherever
salmon spawn in mainstem habitats of the Susitna River. The mainstem Susitna River is divided
into three generalized reaches for the purposes of this study plan: the Lower River (RM ~30-98),
Middle River (RM 98–150), and Upper River (RM 150–234). Devils Canyon extends from
approximately RM 150 to RM 164.
9.7.4 Study Methods
Descriptions of the study methods are organized below by objective. This is a multi-year study
initiated in 2012. The methods below refer to research to be conducted in 2013 and 2014.
9.7.4.1 Objective 1: Capture, radio-tag, and track adults of five species of Pacific
salmon in the Middle and Upper Susitna River in proportion to their
abundance. Capture and tag Chinook, coho, and pink salmon in the Lower
Susitna and Yentna rivers.
Tasks to address Objective 1 include the following:
• Install and operate two fishwheels at approximately RM 30 of the Susitna and two
fishwheels on the lower Yentna River from late May through August 2013 and 2014.
• Supplement the fishwheel effort in the Lower River with gillnet/tangle nets to address
potential size selectivity of capture and augment catch totals.
• Install and operate two fishwheels at Curry (RM 120) from early June through September
in 2013 and 2014 (Figure 9.7-1). Supplement fishing effort for Chinook salmon in the
Middle River by operating a fishwheel in Devils Canyon below the impediments from
late June through late July in 2013 and 2014.
• Radio-tag a total of 1,400 Chinook salmon (700 in the Yentna River and 700 in the
Susitna River at RM 30) and 600 coho and 200 pink salmon in the Susitna River at RM
30 in 2013 and 2014.
• Radio-tag 400 Chinook salmon and 200 each of chum, sockeye, pink, and coho salmon in
the Middle River at Curry (RM 120). Apply as many of the 400 radio tags for Chinook
salmon in Devils Canyon.
FINAL STUDY PLAN SALMON ESCAPEMENT STUDY 9.7
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.7-5 July 2013
• Assess the degree to which radio-tagged fish are representative of all salmon passing
each of the tagging sites (e.g., test for size selectivity, compare mark rates among
spawning areas).
• Evaluate the potential for handling-induced changes in fish behavior based on the post-
release survival and migration rates of radio-tagged fish.
Meeting the goals of this study will be aided by radio-tagging fish of each species in a manner as
representative of each species’ “population” in the Lower and Middle River as possible.
Tagging particular stocks and/or sizes of fish at different rates than others can often be
accommodated during data analysis (Seber 1982; Schwartz and Seber 1999) but could weaken
inferences about relative distribution among tributaries and habitat uses of the Middle River such
as the relative distribution of spawning fish, migratory behaviors, any fish passage above Devils
Canyon, and the river-wide abundance of Chinook and coho salmon. There are multiple ways to
assess whether fish passing the tagging sites are equally vulnerable to being radio-tagged. Of
greatest importance is to survey spawning areas to determine the size composition of tagged and
untagged fish (size distributions) and determine the proportion of fish in different areas that
contain a tag (i.e., the mark rate). Statistically significant differences in mark rates among areas
would suggest unequal vulnerability; differences in the size distributions of the marked and
unmarked fractions of the fish would suggest size-selective capture and tagging.
9.7.4.1.1 Fish Capture
Fishwheels will be used to capture adult salmon for tagging. Two fishwheels will be operated at
approximately RM 30 in locations that were fished in 2010–2012. Two fishwheels will be
operated on the lower Yentna River during a similar period, and in the same locations as have
been operated for three decades. Two fishwheels will also be operated in 2013 and 2014 near
Curry (RM 120) from the first week of June through September at the same two locations in
1981–1985 and in 2012. In addition, at least one fishwheel will be operated in the Middle River
in lower Devils Canyon at approximately RM 150-151 and below the first of three impediments
in Devils Canyon. The Middle River fishwheels consist of aluminum pontoons, three baskets,
and two partially submerged live tanks for holding fish in river water. A tower and winch
assembly will be used to adjust the height of the baskets and ensure that the baskets are fishing
within 20 centimeters (cm) of the river bottom. Net leads will be installed between fishwheels
and the adjacent riverbank to direct fish away from the bank and into the path of the fishwheel
baskets. Fishwheels will be operated 8–12 hours per day. A two-person crew will staff the
fishwheels during operations; when the crew is to be absent from the fishwheel for more than 1
hour, the fishwheel baskets will be raised from the water and stopped. Fishwheels operated in
the Lower River will be of similar construction, operated in a similar manner, and will be staffed
at all times during operation (Yanusz et al. 2011).
Fishwheel effectiveness, expressed as a fraction of the passing salmon run it captures, often
varies within and among seasons. Also known as the catchability coefficient, effectiveness
changes with water depth under the fishwheel and water velocity around the fishwheel. The
overall abundance of fish in the river at any one time may also affect effectiveness. Variable
effectiveness within a season is most problematic for a study of this nature if it varies across the
period of the annual run of a particular species and less problematic if it varies across species.
FINAL STUDY PLAN SALMON ESCAPEMENT STUDY 9.7
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.7-6 July 2013
Fish later or earlier within a run of a particular species can represent fish of different sizes, ages,
and ultimately, fish bound for different habitats. Therefore, stable effectiveness across time,
body size, and spawning destination is ideal, and assumptions will need to be tested by
appropriate data collection at the fishwheels and surveys of spawning areas. If sufficiently large
numbers of fish can be tagged and later examined, any changes in effectiveness can be
compensated for by stratification of results.
9.7.4.1.2 Radio-tagging
ATS pulse-coded, extended-range tags will be applied to a subset of salmon captured in the
Lower and Middle river fishwheels. There are 100 unique codes on each available frequency.
Model F1835B transmitters will be used for pink salmon (16 grams, 30-centimeter-long antenna,
96-day battery life); Model F1840B tags for sockeye, coho, and chum salmon (22 grams, 30-
centimeter antenna, 127-day battery life); and Model F1845B tags for Chinook salmon (26
grams, 41-centimeter antenna, 162-day battery life). All transmitters will be equipped with a
mortality sensor that changes the signal pattern to an “inactive” mode for the remainder of the
season once the tag becomes stationary for 24 hours. All of the radio tags will be labeled with
return contact information. Each tag will be tested immediately prior to deployment to ensure it
is functioning properly upon release.
Only uninjured fish that meet or exceed a specific length threshold will be radio-tagged; i.e.,
Chinook salmon with a mid-eye to fork length (METF) of ≥ 500 millimeters; coho, sockeye, and
chum salmon ≥ 400 millimeters; and pink salmon ≥ 325 millimeters. All fish to be tagged will
be placed in a water-filled, foam-lined, V-shaped trough. To minimize handling time (i.e.,
achieve < 1 minute per fish) and tagging-related effects on fish behavior, anesthetic will not be
used. Radio tags will be inserted orally into the stomach of the fish using a piece of PVC tubing
(1/3-inch diameter and 18 inches long) with the tag antenna left to protrude from the mouth. All
radio-tagged salmon will be measured to determine mid-eye -to-fork length (to the nearest
centimeter), and sexed based on external morphological characteristics (coloration, body and fin
shape, jaw morphology). Radio-tagged fish at Curry will be tagged with a spaghetti tag to assess
tag loss, evaluate the effects of spaghetti-tagging on post-handling behavior and final spawning
destination, and to provide an external mark for anglers to recognize a fish that has a radio tag.
Radio-tagged fish will be sampled for scales (to age) and tissue for genetic baselines (see Section
9.14, Genetic Baseline Study for Selected Fish Species).
To minimize any effects from fish holding, salmon will typically be tagged immediately upon
capture. All fish will be released immediately after tagging. All fish captured will be inspected
for radio and spaghetti tags.
9.7.4.1.3 Spaghetti-Tagging
Spaghetti-tagging will also augment the ability to test assumptions about the representativeness
of fish captured in the fishwheels. The fishwheels may capture more fish of some species than
will be needed for radio-tagging alone, and additional marking of fish will provide more
information to test assumptions about how representative the captured fish are of the population
of fish passing fishwheel sites than the radio tags alone. A portion of these additional fish
captured will be spaghetti-tagged, and this portion will vary among species according to
FINAL STUDY PLAN SALMON ESCAPEMENT STUDY 9.7
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.7-7 July 2013
availability of fish above radio-tagging goals and the opportunities available for examining fish
subsequent to the tagging event.
If similar catches are obtained as in 2012, all of the Chinook salmon captured at Curry that are
above the daily radio-tagging goals will be spaghetti-tagged. Tagged Chinook salmon can be
subsequently examined in several upstream tributaries to test study assumptions and determine
the fraction marked in the different stocks. Based on the 2012 results, we expect few or no coho
salmon caught at Curry above the radio-tagging goal of 200 fish.
Sockeye and chum salmon that spawn above Curry will be available for counting and examining
for marks in clear-water side channels and sloughs, and the Portage Creek and Indian River
tributaries. Given the number of radio tags deployed (200/species), some additional marking of
sockeye and chum with spaghetti tags may enable a test for the assumption that capture and
marking of fish will be in proportion to stock-specific abundance passing Curry. It is expected
that insufficient numbers of pink salmon could be spaghetti-tagged (and later examined) to
develop defensible mark-rate estimates in 2013 (an “off-peak” year). In 2014, although a “peak-
year”, experience in the area in 2012 suggests there are few places to examine significant
numbers of pink salmon on the spawning grounds. However, should it become clear during the
2013 field effort that spawning ground surveys could be more successful, spaghetti tags may be
applied to pink salmon in 2014.
9.7.4.1.4 Daily Tagging Goals
Recent (2012) and historical (1981–1985) fishwheel catches, effectiveness, and salmon run
timing will guide tag application rates over the season. In 2012, Chinook salmon were captured
at RM 30 from the last week of May through the first week of July.
Across the five years from 1981 to 1985, Chinook salmon were caught at Curry from as early as
June 9 (range June 9–20) to as late as August 20 (range July 29–August 20), with midpoints of
the annual runs ranging from June 9–25. During those studies, catches ranged from 201–379
(average 301) for sockeye salmon, 93–350 (average 215) for coho salmon, 861–4,228 (average
2,131) for chum salmon, and 17,394 for the 1984 even-year pink salmon run. Midpoints of the
annual migrations at Curry ranged from approximately August 4–5 for sockeye, August 12–13
for coho, August 3–15 for chum, and July 31–August 7 for pink salmon. In 2012, the run timing
in the Middle River was within the historical ranges described above. The runs at Curry in 2012
were most similar to those in 1985.
As was done in 2012, the early season tagging rates of fish captured in the fishwheels will be
developed prior to the season and will be based on average historical run timing and expected
daily fishwheel catches at Curry. These initial radio-tagging rates will be adjusted in-season
using run timing information from the fishwheels in the Lower Susitna River (RM 30) and the
ratio of current year’s daily catch at Curry to the expected daily fishwheel catch based on
historical data.
9.7.4.1.5 Numbers and Size of Marked and Unmarked Fish at Selected Locations
To test if Chinook, sockeye, and chum salmon passing fishwheels are equally vulnerable to being
captured and radio-tagged, fish will be examined on selected spawning grounds to develop two
FINAL STUDY PLAN SALMON ESCAPEMENT STUDY 9.7
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.7-8 July 2013
primary metrics: estimates of the proportion of fish tagged (mark rate) and the size distributions
of tagged and untagged fish.
Weirs on tributary streams and aerial and foot surveys will be used to count live and dead fish.
Combined with fixed-station and aerial relocating data, these will provide counts of marked and
unmarked fish. Lengths of dead fish will be measured to the nearest centimeter and sex and
spawning success noted.
9.7.4.1.6 Examining Handling-Induced Changes in Behavior
An assumption of this study is that the behavior of radio-tagged fish is not materially affected by
the capture and handling process. By materially affected, we mean that the capture and tagging
does not affect the final spawning destination of a fish and/or its migration behavior once it has
recovered from the tagging event and resumed its migration. If (and when) sufficient genetic
structure can be found among stocks of various species in the Susitna River, genetics could offer
a reasonably good test of whether handling may have influenced the final destination of tagged
fish. Until then, this assumption cannot be tested directly, but there are several indirect ways to
assess its potential magnitude.
The post-release survival and travel time (days) to first detection at upstream fixed-station
receivers will provide an indication of the level of handling-induced changes in behavior. Long
delays to resume upstream migration and high mortality rates would be indicative of significant
changes in behavior; little delay and low mortality rates would be indicative of little effect.
Second, we will compare the upstream movement (delays and rates of travel) of tagged fish that
were subjected to different holding densities and holding times in the fishwheels. Third,
although potentially confounded with different stock-specific vulnerabilities to capture, tag mark
rates at spawning locations based on visual observations and telemetry detections (number of
tags) can provide an indication of possible handling-induced changes in behavior. Stratification
of results by spawning destination based on mark rates can help mitigate any effects of
differences that this source of post-release changes in spawning destination might have on our
conclusions. Finally, we expect that the fishwheels will recapture some of our radio-tagged fish
and the post-release migratory behavior of these already tagged fish will provide additional data
on the effects of the fish capture process, including any potential cumulative handling effects.
Note that this is not an issue if the effect is binomial in nature or simply a significant “on” or
“off” with any individual fish. The radio-tag study design allows the fish that drop back and do
not resume their upstream migration to be censored (removed) from the experiment and
subsequent analyses. The issue is more with subtle effects that could go undetected but
materially affect conclusions.
9.7.4.1.7 Assessing Any Stock- and Size-selective Capture
Fish will be randomly selected from the fishwheels for tagging. To assess whether these fish are
representative of all fish in the in the river, several assumptions need to be tested.
An assumption of equal probability of capture across fish from all spawning destinations can be
tested indirectly by examining several sources of information. If there are unequal probabilities
of capture among spawning stocks, it will be caused by, and manifest itself, in multiple ways.
FINAL STUDY PLAN SALMON ESCAPEMENT STUDY 9.7
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.7-9 July 2013
Fishwheel effectiveness across time: The main assumption of this study component is that the
radio tags are deployed at the fishwheels in proportion to abundance for each species. To help
evaluate this assumption at Curry, we will compare the relative effectiveness of each fishwheel,
as determined from the ratio of fish caught by a fishwheel and the number of fish observed with
DIDSON sonar system operated in close proximity to the fishwheel across multiple time periods,
and river discharge. The DIDSON will also be used to qualitatively assess fish approach
behavior at the fishwheel relative to discharge and fish abundance. We will also compare the
catch per unit effort (CPUE; fish per fishwheel hour) over time and across a range of discharges.
Differences among stocks: To assess whether fish from a particular spawning area were right or
left bank-oriented with respect to the capture site, we will compare the proportion of fish
migrating into specific areas with the collection bank. Assuming data are suited to statistical
analysis, we will also use contingency table analysis to compare mark rates over time and areas
at upstream locations (i.e., at weirs and from ground surveys). If tags are deployed in proportion
to abundance, then we would expect mark rates to be constant across both temporal and spatial
strata in these spawning ground areas. One concern is that mainstem fish could be more
vulnerable to the fishwheels because they linger or mill upstream and downstream of capture
sites. Recaptures of radio-tagged fish at the tagging site fishwheels will provide a good test of
whether milling fish are exposed to greater capture rates. In addition to quantitative and
qualitative assessment of subsequent behavior of these recaptured fish, we will compare the final
destinations (mainstem/tributary) of recaptured fish to other tagged fish to determine whether
fish that spawn in the mainstem are recaptured at a higher rate.
Size-related (and age-related) selectivity will be tested using Kolmogorov-Smirnov (K-S) two-
sample tests. For each species, we will compare the cumulative length-frequency distributions of
(1) radio-tagged and spaghetti-tagged fish and those fish randomly sampled on the spawning
grounds; (2) radio-tagged and spaghetti-tagged fish and all other fish sampled for length at the
Curry fishwheels; and (3) radio-tagged and spaghetti-tagged fish captured in individual
fishwheels. Using data from similar sources, contingency table analyses and Chi-square tests
will be used to compare the sex and age composition of fish radio-tagged by species. Size-
related bias can usually be eliminated by size stratification of results.
9.7.4.2 Objective 2: Determine the migration behavior and spawning locations of
radio-tagged fish in the Lower, Middle, and Upper Susitna River.
This is a continuation of the multi-year study initiated in 2012. Tasks to meet Objective 2
include the following:
• Track the locations and behavior of radio-tagged fish using an array of fixed-station
receivers and mobile-tracking surveys. Aerial surveys will begin in July and end in early
October each year.
• Conduct boat- and ground-based surveys to locate holding and spawning salmon to the
level of microhabitat use.
Three groups of radio-tagged fish will be tracked: (1) adult Chinook, coho, chum, pink, and
sockeye salmon will be radio-tagged and released in the Middle River at Curry (RM 120); (2)
Chinook, coho, and pink salmon tagged in the Lower Susitna River (RM 30); and (3) Chinook
salmon tagged in the lower Yentna River (Figure 9.7-1). The three study components and data
FINAL STUDY PLAN SALMON ESCAPEMENT STUDY 9.7
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.7-10 July 2013
analyses will be tightly coordinated. All mobile (aerial, boat, and foot) and fixed-station receiver
data will be analyzed together, and analysis products will be characterized in a consistent
manner.
The primary function of the telemetry component is to track these tagged fish spatially and
temporally with a combination of fixed and mobile receivers. Time/date stamped, coded radio
signals from tags implanted in fish will be recorded by fixed station or mobile positioning. All
telemetry gear (tags and receivers) across both studies will be provided by ATS, Inc. (Advanced
Telemetry Systems, www.atstrack.com).
The types of behavior to be characterized include the following:
• Arrival and departure timing at specific locations/positions
• Direction of travel
• Residence time at specific locations/positions
• Travel time between locations/positions
• Identification of migratory, holding, and spawning time and locations/positions
• Movement patterns in and between habitats in relation to water conditions (e.g.,
discharge, temperature, turbidity)
These data, in conjunction with habitat descriptions, will allow characterization of migratory
behavior and final destinations for salmon in mainstem habitats (main channel, slough, side
channel) and tributaries. In addition, observed spawning locations will be characterized at a
microhabitat level (e.g., depth, velocity, substrate). Spawning or final locations of tagged fish
will be used to determine the number and proportion of the tagged fish of each species using
mainstem habitats.
9.7.4.2.1 Fixed-Station Monitoring
Stand-alone operating telemetry arrays will be deployed at strategic locations on the Lower,
Middle, and Upper River to provide migration checkpoints and develop spawning ground
inventories and the fates of individual tagged fish. Each station will include a radio receiver,
power supply, antenna switcher, and two or three aerial antennas. Antennas may be mounted in
trees or on tripod-mounted poles and orientated to distinguish between upstream and downstream
movements of fish (i.e., direction of travel). Receivers will be programmed to scan all
frequencies and record coded tags. Initial station installation will include range testing to define
the expected detection range (approximately 900 linear feet at 10 feet water depth, configuration
dependent) of each antenna. Standard reference or “beacon” tags will be deployed at most fixed
stations to provide a continuous record of known signal detections. Fixed stations will be
manually downloaded (i.e., by the field crew) on a weekly basis unless a remote communication
protocol is established. Raw telemetry files will be archived and then imported into custom
database software for processing and summarizing throughout the season, and for post-season
reporting.
FINAL STUDY PLAN SALMON ESCAPEMENT STUDY 9.7
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.7-11 July 2013
Figure 9.7-1 shows the locations of the radio telemetry fixed stations in the Lower, Middle, and
Upper Rivers. Proposed locations for radio telemetry fixed stations in the Middle and Upper
River are also shown in greater spatial resolution in Figure 9.7-2 and are listed below.
1. Lane Creek area (~ RM 113.0)
2. Middle River Gateway - (RM 123.7)
3. Slough 11 (~ RM 135.3)
4. Indian River confluence (RM 138.6)
5. Slough 21 (~ RM 141.1)
6. Portage Creek confluence (RM 148.8)
7. Cheechako Creek confluence (RM 152.4)
8. Chinook Creek confluence (RM 157.0)
9. Devil Creek area (RM 164.0)
10. Kosina Creek confluence (RM 206.8)
The Lower River stations were chosen to represent all significant tributaries that are known to
contain or may contain Chinook salmon (Figure 9.7-1). The Middle and Upper River sites were
chosen based on the following: (1) the need to provide geographic separation of the Middle
River area to describe migration and spawning behaviors, and (2) monitoring at the appropriate
resolution through the Upper River area to quantify passage through Devils Canyon. See below
for additional details about the telemetric monitoring in Devils Canyon (Objective 3).
9.7.4.2.2 Telemetry Aerial Surveys
Aerial surveys of the mainstem Susitna from RM 22 to Kosina Creek will be conducted by
helicopter to allow relatively accurate positioning of tagged fish, to locate spawning areas, and to
make visual counts of fish in clear water areas, all with respect to mainstem habitat types. Aerial
surveys will begin in July and end in late October (≈16 weeks). Survey timing may be adjusted
depending on the observed fishwheel catches in the Lower and Middle River. Surveys will be
scheduled at five-day intervals with the intent to ensure a maximum of seven days between
surveys with weather contingencies. In the event that fixed stations indicate that no tagged fish
have migrated upstream of Devils Canyon, aerial surveys to at least Kosina Creek will be
conducted at least three times to confirm these results. If radio-tagged fish are detected moving
upstream in the mainstem at the Kosina Creek telemetry station, aerial surveys will be extended
to locate those radio-tagged fish and visually survey for untagged fish.
Surveys via helicopter can be conducted at lower elevations and at slower speeds than can be
achieved using fixed-wing aircraft, and therefore will allow more time for signal acquisition,
higher spatial resolution, and fish/habitat observations. Fixed-wing surveys are most appropriate
when the study goal is a spatial resolution of tagged fish locations to be within approximately
800 meters (i.e., to the nearest 0.5 river mile), and some fixed-wing surveys will be conducted
about every 10 days. The goal for helicopter-based surveys is to be within approximately 300
meters (1,000 feet), as well as to determine whether the fish is in off-channel or mainstem
habitat. Higher precision will be achievable in reaches where conditions are most favorable.
Geographic coordinates will be recorded for each detected signal using an integrated
FINAL STUDY PLAN SALMON ESCAPEMENT STUDY 9.7
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.7-12 July 2013
communication link between the telemetry receiver and a global positioning system (GPS) unit.
The position of the fish will be determined as that position of the aircraft at the time of the
highest signal power. Range testing of the mobile aerial setup will be conducted in the Lower
River to confirm detection ranges for typical flying heights, receiver gains, and antenna
orientation, as well as to work with the helicopter pilot to refine the methods for achieving
highest spatial resolution.
The mainstem aerial surveys will need to cover over 200 river miles (RM 22 to RM 230), and
multiples of that total when side channels and braids of the Lower River are included. To
allocate survey effort efficiently and to the highest priority needs, resolution will be a function of
fish behavior. The highest priority and highest resolution needs will be for fish that appear to be
holding or spawning. For migrating fish, resolution to the nearest 500 meters (~1,500 feet) of
river will generally be sufficient. The proposed frequent surveys will provide a means of
focusing a higher-resolution and time-intensive tracking effort on identifying exact locations of
spawning and holding fish. To do this, the aerial survey team will have available the most recent
observed river locations (to the nearest 1 kilometer [0.62 mile]) of all mainstem fish “at large”
(i.e., tagged and not tracked in a tributary). During the survey, the “river km” of all detected fish
will be compared to the last seen location from previous surveys to ascertain whether its position
has changed by more than 2 kilometers (1.25 miles). When tagged fish are within 2 kilometers
of their last seen location, the helicopter will circle at a lower altitude to pinpoint the fish
location to mainstem, side channel, or slough habitats.
As well, when aggregations of two or more tagged fish are found “stationary” (i.e., within 2
kilometers [1.25 miles] on one or more surveys) and/or when visual observations of spawning
fish are made from the helicopter, ground- and boat-based surveys will pinpoint spawning
locations to within 5–10 meters (16–32 feet). This protocol will be particularly important for
ensuring coverage of any suspected Lower River habitats with the appropriate level of spatial
resolution.
The channel location (mainstem, side channel, slough) and relative water turbidity at the location
of the fish will be classified for each tag detected (time stamp, frequency, code, power level)
during aerial surveys. If other fish can be seen in the area of the tag position, their relative
abundance will be estimated to provide context for the tag observation.
Tag identification, coordinates, and habitat type data will be archived and systematically
processed after each survey. A data handling script will be used to extract unique tag records
with the highest power level from the receiver files generated during the survey. These records
will be imported into a custom database software application (Telemetry Manager) and
incorporated into a Geographic Information System (GIS) based mapping database.
Geographically and temporally stratified data of radio-tagged fish will be provided to the habitat
sampling team and Instream Flow Study to inform their field sampling efforts.
Fixed-wing aerial surveys of tributary systems of the Susitna and Yenta rivers will be conducted
from RM 20 to Devils Canyon and the upper Chulitna River at 7- to 10-day intervals from late
June through September. These surveys will provide fish locations to the nearest river mile (1.6
km) and will help to fully characterize the fates of fish tagged in the Lower and Middle rivers.
Although these will provide less precise spatial resolution of fish locations (and habitat use) than
from helicopter surveys, fixed-wing surveys will more effectively cover the very large lineal
FINAL STUDY PLAN SALMON ESCAPEMENT STUDY 9.7
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.7-13 July 2013
distances of the Susitna River tributaries than possible by helicopter (and in areas where high
spatial resolution is not required).
9.7.4.2.3 Lower River Surveys
Helicopter surveys of the Lower River will cover mainstem areas from RM 22 to the confluence
of the Chulitna River (RM 98). This reach is highly braided with side channels and sloughs, so
complete coverage will require considerable effort and in-flight route tracking. With the survey
protocol outlined above and the number of tags anticipated to be at-large on any one survey, this
area will require up to two survey days to complete.
9.7.4.2.4 Middle River Surveys
Helicopter surveys of the Middle River will cover mainstem areas from the confluence of the
Chulitna River (RM 98) through Devils Canyon (≈ RM 164). This reach (66 miles) will require
approximately one day to complete, and as much as two days late in the season when all tags are
deployed.
9.7.4.2.5 Upper River Surveys
Helicopter surveys of the Upper River will generally be triggered by detection of fish moving
above fixed-stations at the Portage and Devils Canyon stations. Once fish are detected above
Devils Canyon, aerial surveys will cover the mainstem areas from Devils Canyon (≈ RM164) to
the confluence of the Kosina Creek (RM 206.8). This reach will include approximately 53
relatively confined river miles. This survey will require approximately one survey day; less
when done in conjunction with Middle River surveys (i.e., when less conveyance time is
involved). Radio-tagged fish above Devils Canyon will be located at a spatial resolution in
habitat types similar to the Middle and Lower River surveys.
9.7.4.2.6 Boat and Ground Surveys
Telemetry surveys will also be conducted by boat and on foot to obtain the most accurate and
highest resolution positions of spawning fish. Using the guidance of fixed-station and aerial
survey data on the known positions of tagged fish, specific locations of any concentrations of
tagged fish that are suspected to be spawning will be visited to obtain individual fish positions.
It is expected that resolution will be within 5–10 meters (16–32 feet) in turbid water and within
2–3 meters (6.5–10 feet) in clear water (dependent on density and highest resolution at low
densities). Underwater stripped-coax antennas and judicious use of signal gain control will allow
locating tagged fish and recording their geographic position with a GPS. These data will be
collected in concert with the field activities and provided to the habitat suitability sampling team
to inform their sampling efforts. These surveys will be conducted approximately weekly during
the July through September mobile tracking period.
9.7.4.3 Objective 3: Characterize adult salmon migration behavior and timing within
and above Devils Canyon.
The tasks to achieve Objective 3 include the following:
FINAL STUDY PLAN SALMON ESCAPEMENT STUDY 9.7
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.7-14 July 2013
• Establish an array of fixed-station receivers at and above Devils Canyon to monitor the
behavior of radio-tagged fish from early June to October each year (Figures 9.7-1 and
9.7-2).
• Conduct aerial surveys of the Upper River to locate tagged and other salmon.
• Locate spawning and holding salmon upstream of Devils Canyon.
• Assess the feasibility of operating a fish weir at or near the dam site to provide an
accurate count of resident fish passing that location, or anadromous adults that are able to
successfully migrate upstream through Devils Canyon into the Project Area.
• Assess the feasibility of operating an acoustic sonar array at or near the dam site to
provide an accurate count of resident fish passing that location, or anadromous adults that
are able to successfully migrate upstream through Devils Canyon into the Project Area.
A combination of fixed-station receivers below (at the Portage Creek confluence, RM 148.8),
within (RM 150 and RM 164), and above Devils Canyon will be used to determine the migration
timing and behavior of any radio-tagged salmon that pass into the Upper River area (Figure 9.7-
2). Fixed-station receivers will be deployed at locations where they will have the highest
probability of detecting radio-tagged salmon. The fixed station deployed at the confluence with
Kosina Creek will provide additional information that can be used to assess the detection
efficiencies for all mainstem fixed-station receivers downstream from this site. The data from
these receivers will also be used to identify the broad reaches of the Upper River to guide the
aerial and ground-based survey efforts needed to identify spawning areas.
The mobile survey data will aid in confirming the presence of radio-tagged fish, and locating any
fish not detected at downstream fixed-station receiver sites. These additional detections will be
combined with the aerial survey data to estimate detection efficiencies for each fixed-station
receiver. The timing and proportion of all tagged salmon that pass Devils Canyon will be
calculated and compared to the remaining tagged population, and their final spawning locations
will be identified.
Based on site-specific data obtained during the 2013 study season, AEA will evaluate the
feasibility of placing a weir or sonar counting station at or near the dam site during the 2014
study season. This is aimed at obtaining an accurate count of any resident or anadromous fish
passing the site. For anadromous fish, their presence will indicate that they were successfully
able to migrate upstream through Devils Canyon into the Project area. Assessment of the
feasibility for a fish weir will include a determination as to whether there exists a site with
suitable physical characteristics (access, channel configuration, water depth and velocity profile,
substrate size, and land above OHW for monitoring facilities). Assessment of the feasibility for
a sonar array will include a determination as to whether there exists a site with suitable physical
characteristics (access, channel configuration, water depth profile, substrate size, and land above
OHW for monitoring facilities). The Initial Study Report (ISR) will report the evaluation of
feasibility.
FINAL STUDY PLAN SALMON ESCAPEMENT STUDY 9.7
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.7-15 July 2013
9.7.4.4 Objective 4: Use available technology to document salmon spawning
locations in turbid water in 2013 and 2014.
This objective involves using side-scan and/or Dual Frequency Identification Sonar (DIDSON)
to characterize any suspected salmon spawning in turbid water of the mainstem habitats of the
Susitna River.
Previous studies in the mainstem Susitna River have relied on late-season visual surveys of redds
to identify and characterize salmon spawning that occurs in turbid water after temperatures have
fallen and the river water has cleared. The efficacy of this technique in the Susitna River
mainstem habitats has not been evaluated and it may underestimate the extent of spawning
activity in turbid water. Late-season visual surveys of redds may fall below 100 percent
detection because detection may vary with discharge, suspended sediment levels, etc.
An AEA-sponsored study in August 2012 set out to examine the feasibility of using sonar to find
and characterize spawning activity in turbid water. Technical difficulties in August and flow
conditions and fish behavior in September 2012 precluded a rigorous test of this method. The
method will be used again in 2013 to examine the feasibility of sampling turbid water to quantify
spawning activity. Sonar has the potential to detect redds in turbid water and confirm spawning
activity by directly monitoring fish behavior. Radio telemetry provides a powerful tool to
identify suspected spawning activity, but subsequent sampling of fish with sonar and/or other
methods may be needed to help determine whether spawning has actually occurred. Net
sampling may help to determine the degree of sexual maturation and reduce confusion between
holding and spawning areas in some instances. If spawning behavior such as the digging of
redds is not obvious from the DIDSON imagery, and redds are not clearly visible from the side-
scan imagery, additional sampling of the gravel by attempting to pump eggs would be required to
confirm spawning. Initial emphasis in 2013 will be placed on any suspected Chinook salmon
spawning areas in turbid water identified in the 2012 radio telemetry study.
9.7.4.4.1 Sonar Equipment and Methods
The EdgeTech 4125 600/1600 kHz side-scan sonar can generate high-resolution images with an
across-track resolution of 0.6 centimeters (~0.25 inch), independent of the range sampled. The
system is well suited for collecting data over large areas. Depending on the water depth, the high
frequency side-scan sonar can sample a swath of up to 50 meters (164 feet). As a rule of thumb,
if the transducer is 1 meter (3.28 feet) above the bottom, one can “see” an approximately 10-
meter (32.8-foot) wide swath on each side of the survey boat (port and starboard). The minimum
water depth required for the deployment of the transducer is approximately 0.5 meter (1.64 feet).
The survey will be conducted at a boat speed of approximately 1 meter per second (3.28 feet per
second), slower in shallow water if there is a danger of hitting obstacles. Where the side-scan
sonar encounters aggregations of redds, the survey will periodically be paused to supplement the
data with stationary spot checks with a DIDSON.
DIDSON is a high-resolution imaging sonar that provides video-type images over a 29-degree
field of view and can thus be used to observe fish behavior associated with spawning, i.e.,
dynamic behavior that cannot be identified on the static side-scan images. To obtain high-
quality images of adult salmon the maximum range will be limited to 15 meters (49 feet).
Within this field of view, evidence of spawning behavior (e.g., redd digging, chasing, spawning)
will be clearly identifiable. Furthermore, on DIDSON images fish can be classified by size
FINAL STUDY PLAN SALMON ESCAPEMENT STUDY 9.7
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.7-16 July 2013
category, e.g., <40 centimeters, 40–70 centimeters, >70 centimeters (<25 inches, 25–44 inches,
>44 inches, respectively). Although this is not sufficient for definitive species identification, it
will allow recognition of smaller resident fish, medium-sized adult salmon, and large Chinook
salmon. DIDSON has successfully been used to survey salmon redds in the Columbia River.
If deemed feasible based on results from 2012, acoustic surveys will be made from early August
through September to coincide with the times when sockeye, chum, Chinook, and pink salmon
are actively spawning.
9.7.4.4.2 Sonar Data Analysis and Reporting
All sonar data will be collected along with a differential GPS with 10 Hertz (Hz) positioning
rate. The GPS coordinates together with heading, pitch, and roll information will allow
matching of side-scan and DIDSON data with any visual and telemetry-based ground-truthed
data. The side-scan analysis will provide locations of individual redds or redd fields. The
DIDSON data analysis will provide the coordinates, coverage, and duration of each station
surveyed, together with the mean number of fish observed in the field of view, their size
categories (<40 centimeters, 40– 0 centimeters, >70 centimeters [<25 inches, 25–44 inches, >44
inches, respectively]), and a qualitative description of their behavior.
9.7.4.5 Objective 5: Compare historical and current data on run timing, distribution,
relative abundance, and specific locations of spawning and holding salmon.
A comparison will be made of this study’s results from 2012–2014 to the historical results that
characterized the relative abundance, locations of spawning and holding salmon, and use of
mainstem, side channel, slough, and tributary habitat types by adult salmon.
Research conducted in the early 1980s provided information relevant to this study. Annual
abundance estimates relevant to at least four fishwheel sites along the Susitna River mainstem
were developed in each of three years (1983–1985). These abundance estimates were
apportioned to mainstem, sloughs, and tributaries, and the results will be useful for assessing the
potential impacts of the Project. One weakness of these studies was that they relied heavily on
visual observations of fish (and abandoned late-season redds). These methods and results may
underestimate the use and relative importance of mainstem habitats, many of which occur in
turbid water during a substantial portion of the spawning period. Another concern is that data
collected approximately 30 years ago may not characterize the current habitat use in the
mainstem Susitna River.
This study will address both of these concerns by deploying a similarly scaled study of the
spawning runs to the Susitna River in 2012–2014 and by using radio telemetry and sonar
technology not available in the 1980s. We expect both methods to provide a more rigorous
characterization of the use of mainstem habitats than methods used in the 1980s. To the extent
spawning distribution and habitat use in the current study are similar to earlier studies, it will
greatly increase the sample size and confidence in the conclusions from studies in both periods.
Therefore, it will be important to explicitly compare and contrast the distribution and habitat use
of salmon in the Lower, Middle, and Upper River habitats of the Susitna River.
FINAL STUDY PLAN SALMON ESCAPEMENT STUDY 9.7
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.7-17 July 2013
9.7.4.6 Objective 6: Generate counts of adult Chinook salmon spawning in the
Susitna River and its tributaries.
This objective will be addressed by conducting adult salmon spawning surveys (see Objective 1,
Section 9.7.4.1.5) and operating weirs on tributaries (see Objective 8) in 2013 and 2014. The
purpose of this work will be to attempt to establish survey-area mark rates (proportion of fish
tagged in different streams or mainstem habitats) so that inferences can be made about the
representativeness of tagging across stocks. In addition, mark rates from these areas can be used
to estimate the abundance passing the tagging sites (but not the abundance at the recovery site).
If sufficient sampling can be obtained and some assumptions met, some inference can be made
about relative abundance among recovery locations using the estimates of mark rates and the
number of radio-tagged fish present.
Assumptions will be made and tested regarding the representativeness of tagging and proportion
of the run detected visually and by telemetry. A combination of ground-, aerial-, and weir-based
counts will be used. Ground-based surveys will be made where high observer efficiency can be
achieved (e.g., Portage and Indian Creeks). Weirs will be placed on selected tributaries (see
Objective 8). Aerial surveys by helicopter were conducted in July and August 2012. Protocols
will be developed based on experience in 2012 and these will be used again in 2013 and 2014 to
survey the Portage and Indian tributaries of the Middle River.
Aerial survey data will be used to establish estimates of minimum and likely numbers of fish
based on a range of observer efficiencies. These can then be used to establish ranges of possible
species-specific mark rates in 2013 and 2014. Multiple aerial surveys will be flown bracketing
the peak timing of spawning. Survey aircraft will be equipped with telemetry receivers and GPS
to identify positions of tagged and not-tagged Chinook salmon and any other Pacific salmon that
may be observed. The aerial surveys will not provide a direct estimate of the total salmon
abundance in tributaries. Instead, these will provide a minimum count and then help to establish
minimum and likely tributary-specific mark rates, as was done for Portage and Indian tributaries
in 2012.
9.7.4.7 Objective 7: Collect tissue samples to support the Fish Genetics Study.
The task for this objective is to collect genetic samples from adult anadromous salmon in
conjunction with addressing Objectives 1 and 2. Tissue samples will be taken from all radio-
tagged salmon and from all untagged spawning fish that are sampled during spawning ground
surveys. Sample collections will be coordinated with the Genetic Baseline Study team (see
Section 9.14). Similar to 2012, this study will identify the locations of spawning fish and
whenever feasible, collect tissue for use with genetics studies by ADF&G and other researchers.
9.7.4.8 Objective 8: Estimate the system-wide Chinook and coho salmon
escapement to the Susitna River above Yentna River and the distribution of
those fish among tributaries of the Susitna River in 2013 and 2014.
A commonly applied two-event, capture-recapture experiment will be used to estimate the
annual abundance of Chinook salmon in the entire Susitna River drainage and the coho salmon
abundance in the Susitna River above the Yentna River confluence. Such methods to estimate
salmon escapement are ubiquitous in Alaska and along the West Coast of North America. In the
Susitna River, the capture event will be provided by fishwheels operating throughout the
FINAL STUDY PLAN SALMON ESCAPEMENT STUDY 9.7
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.7-18 July 2013
seasonal salmon migration. Radio tags will be applied to fish as close to proportional of the
migrating salmon as possible. Later in the salmon migration, a series of recapture sites on
tributaries and mainstem sites will examine salmon to establish the proportion of each species
that has a tag (also known as the species-specific and stock-specific mark rate). Using relatively
simple algebra and making some testable assumptions, an estimate of the total species-specific
abundance that passed the tagging site can be estimated; in this case, the abundance and in-river
escapement at the fishwheels sites on the Susitna (Chinook and coho salmon) and the Yentna
(Chinook salmon) rivers. Length, sex, and genetics information from the tagged and untagged
fish can be used to assess the validity of most assumptions. Behavior of radio-tagged fish
following tagging also provides information for evaluating two critical assumptions: that you
know how many tagged fish have “entered” the experiment, and whether their behavior
compromises the experiment.
Fishwheels on the Yentna and Lower Susitna rivers will be used to capture fish for marking.
Weirs on tributaries of the Susitna River will be used to recapture fish for estimating the
proportion of each species that has a tag. At the weir recapture sites, Chinook salmon will be
counted and inspected for tags. Weirs will be operated on the Deshka River (which has been
operated by ADF&G for many years), and on Willow Creek and the Middle Chulitna River, as
well as Talachulitna River and Lake Creek in the Yentna drainage. These weir sites were chosen
based on the numbers of fish using the systems based on a long time series of annual aerial
survey data and the ability to weir the sites. Finally, the fishwheels at Curry will also examine a
relatively large number of fish of each species and the mark rates (of lower river tags) in the
Curry fishwheels. The size characteristics of the tagged and untagged fish at Curry can be used
along with weir-based information in estimating escapement and testing assumptions of the
mark-recapture experiment each year.
A two-event, capture-recapture experiment will also be used to estimate the abundance of coho
salmon in the Susitna River upstream of the confluence with the Yentna River. Coho salmon
will be counted and inspected for tags at the weirs on the Deshka River and Willow Creek. In
addition, the middle Chulitna River will be evaluated as a possible site once the 2012 coho
salmon telemetry analyses provide an indication the relative size of the coho salmon return to the
river.
At Willow Creek, a DIDSON unit will likely be used in conjunction with the weir to estimate
Chinook and coho salmon abundance. Past studies at Willow Creek found that, early in the
season during spring runoff, Chinook salmon migrated past the likely weir site when high,
occluded water precluded installation and operation of a weir. The weir will be installed once
the water recedes to levels where the weir can be safely installed. In August and September
when coho salmon migrate into the creek, the weir may be compromised by high water resulting
from rain. During these times, coho salmon abundance will be estimated using DIDSON.
9.7.5 Consistency with Generally Accepted Scientific Practice
The fishwheel capture methods for supplying salmon for biotelemetry studies have been used
around Alaska and elsewhere in North America since the early 1980s, including on the Susitna
River at the locations proposed here (Cannon 1986). Similarly, radio-tracking of tagged adult
salmon by fixed and mobile (aerial and boat) receivers has been established elsewhere, and used
extensively in the Lower Susitna River over the last six years (Yanusz et al. 2007; Yanusz et al.
2011; Merizon et al. 2010) and during the AEA-sponsored salmon tagging at Curry in 2012
FINAL STUDY PLAN SALMON ESCAPEMENT STUDY 9.7
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.7-19 July 2013
(Link et al. in prep). Two-event, capture-recapture experiments are ubiquitous in North America
for assessing salmon abundance.
9.7.6 Schedule
Initial data collection efforts for this multi-year study began in the summer/fall of 2012 and will
continue through the 2013 and 2014 adult salmon migration and spawning seasons. The
schedule allows for one initial and two complete study seasons. The proposed schedule (Table
9.7-1) for completion of the Salmon Escapement Study is as follows:
• Initial data collection in 2012 will consist of: (1) operation of fishweels in the Susitna
near Curry from June through August, (2) radio tagging and tracking of adult salmon (3)
steam counts and carcass surveys in Indian River and Portage Creek (4) HSC surveys of
mainstem spawning habitat for spawning salmon (5) evaluation of side-scan sonar to
identify redds.
• File a supplemental memorandum with the FERC reporting interim 2012 Salmon
Escapement results – First quarter 2013
• Install fishwheels and fixed telemetry stations – May and June 2013 and 2014
• Operate fishwheels in the Lower Susitna and Yentna Rivers – May through August, 2013
and 2014.
• Operate fishwheels in the Susitna River near Curry – June through September, 2013 and
2014.
• Conduct aerial surveys in 2013 and 2104 to relocate radio-tagged salmon – mid-June
through September in the Lower River and from mid-July through early October in the
Middle and Upper River.
• Quality Controlled (QC) Data – December 2013 and 2014.
• QC’d geospatially-referenced relational database – December 2013 and 2014.
• Data analysis – October to December 2013 and October to December 2014
• Initial and Revised Study Reports on 2013 and 2014 activities – anticipated to be filed
during the first quarter of 2014 and 2015, one and two years, respectively, after the FERC
Study Plan Determination (February 2013)
9.7.7 Relationship with Other Studies
The salmon escapement study is interrelated to several other studies (Figure 9.7-3). Four Project
studies will interrelate by providing predecessor information useful to the salmon escapement
study. The Upper River Fish Distribution and Abundance Study (Section 9.5) and Middle and
Lower River Fish Distribution and Abundance Study (Section 9.6) will each provide salmon
distribution information useful for determining travel time, distance and spawning locations
(Objective 1); characterizing migration behavior (Objective 2); characterizing movement in and
above Devils Canyon (Objective 3); and estimating Chinook and coho escapement and relative
distribution among tributaries (Objective 8). The Characterization and Mapping of Aquatic
Habitats Study (Section 9.9) will provide habitat characterization information useful for the
characterization of migration behavior and spawning locations (Objective 2). The Fish Genetic
FINAL STUDY PLAN SALMON ESCAPEMENT STUDY 9.7
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.7-20 July 2013
Baseline Study (Section 9.14) will provide information on Chinook salmon genetic structure
useful for estimation of the relative distribution among tributaries and mainstem spawning
habitats (Objective 8). The Salmon Escapement, along with the Upper River Fish Distribution
Study (Section 9.5) and Middle and Lower River Fish Distribution Study (Section 9.6), will also
interrelate by opportunistically providing genetic tissue samples of Chinook salmon for the
Genetic Baseline Study (Section 9.14).
The Salmon Escapement Study will also interrelate with five other Project studies by providing
useful output information (Figure 9.7-3). Characterization of travel time and distance, spawning
locations (Objective 1), and migration behavior (Objective 2) will provide general information
on salmon distribution and access to habitat, which will be used by the Fish Passage Barriers
Study (Section 9.12) and the Aquatic Resources Access Study (Section 9.13). Characterization
of migration behavior and spawning locations (Objective 2), and fish movement in and above
Devils Canyon (Objective 3) will each provide information on salmon presence above the
proposed dam site, which will be useful to the Future Reservoir Fish Community (Section 9.10)
and the Fish Passage Feasibility Study (Section 9.11). Estimates of Chinook and coho salmon
escapement and relative distribution among tributaries (Objective 8) will provide information on
distribution and relative abundance of Chinook salmon by major tributary, which can be used in
the Analysis of Fish Harvest Study (Section 9.15).
9.7.8 Level of Effort and Cost
The schedule, staffing, and costs will be detailed as the 2013–2014 Study Plan develops. Total
study costs are estimated at $10,000,000. Objectives 1 through 7 would be approximately
$2,400,000 per year and the estimated costs for work associated with Objective 8 would be
$2,600,000 per year.
9.7.9 Literature Cited
AEA (Alaska Energy Authority). 2011a. Aquatic Resources Gap Analysis. Prepared by HDR,
Inc., Anchorage. 107 pp.
AEA. 2011b. Pre-application Document: Susitna-Watana Hydroelectric Project FERC Project
No. 14241. December 2011. Prepared for the Federal Energy Regulatory Commission,
Washington, D.C.
Fair, L.F., T.M. Willette, J.W. Erickson, R.J. Yanusz, and T.R. McKinley. 2010. Review of
salmon escapement goals in Upper Cook Inlet, Alaska 2011. Alaska Department of Fish
and Game, Fishery Manuscript Series No. 10–06, Anchorage.
Cannon, R. 1986. Susitna River aquatic studies review: findings and recommendations of the
Susitna program review team.
Ivey, S., C. Brockman, and D. Rutz. 2009. Area management report for the recreational fisheries
of Northern Cook Inlet, 2005 and 2006. Alaska Department of Fish and Game, Fishery
Management Report No. 09-27, Anchorage.
Merizon, R. A., R. J. Yanusz, D. J. Reed, and T. R. Spencer. 2010. Distribution of spawning
Susitna River chum Oncorhynchus keta and coho O. kisutch salmon, 2009. Alaska
Department of Fish and Game Fishery Data Series No. 10-72, Anchorage.
FINAL STUDY PLAN SALMON ESCAPEMENT STUDY 9.7
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.7-21 July 2013
Schwarz, C. J. and G. A. F. Seber. 1999. Statistical Science. Vol. 14, No. 4, pp. 427-456.
Seber, G. A. F. 1982. The estimation of animal abundance and related parameters. Charles
Griffin and Company, Ltd., London.
Thompson, F. M., S. N. Wick, and B. L. Stratton. 1986. Adult salmon investigations May –
October 1985. Alaska Department of Fish and Game, Susitna Hydro Aquatic Studies
Report Series 13, Anchorage.
Woodward-Clyde Consultants, and Entrix, Inc. 1985. Fish Resources and Habitats in the
Middle Susitna River. Technical Report No. 1. Instream Flow Relationships Series.
Alaska Power Authority Susitna Hydroelectric Project. Vol. 1.
Yanusz, R., R. Merizon, D. Evans, M. Willette, T. Spencer, and S. Raborn. 2007. Inriver
abundance and distribution of spawning Susitna River Sockeye salmon Oncorhynchus
nerka, 2006.
Yanusz, R. J., R. A. Merizon, T. M. Willette, D. G. Evans, and T. R. Spencer. 2011. Inriver
Abundance and Distribution of Spawning Susitna River Sockeye Salmon Oncorhynchus
nerka, 2008. Alaska Fishery Data Series No. 11-12. Department of Fish and Game,
Divisions of Sport and Fish and Commercial Fisheries.
FINAL STUDY PLAN SALMON ESCAPEMENT STUDY 9.7
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.7-22 July 2013
9.7.10 Tables
Table 9.7-1. Schedule for implementation of the Salmon Escapement Study.
Activity 2012 2013 2014 2015
1 Q 2 Q 3 Q 4 Q 1 Q 2 Q 3 Q 4 Q 1 Q 2 Q 3 Q 4 Q 1 Q
Initial studies and Technical Memorandum •
Deploy fishwheels and fixed telemetry
stations
Operate fishwheels and radio tag fish
Conduct aerial telemetry surveys
Aerial and ground escapement visual
counts
Data entry and geospatial database
In-season progress reporting
Preliminary data Analysis
Initial Study Report Δ
Final data analysis
Updated Study Report ▲
Legend:
Planned Activity
----- Follow-up activity (as needed)
• Technical Memorandum
Δ Initial Study Report
▲ Updated Study Report
FINAL STUDY PLAN SALMON ESCAPEMENT STUDY 9.7
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 23 July 2013
9.7.11 Figures
Figure 9.7-1. Susitna watershed showing fish capture sites (fishwheels) and the locations of fixed-station telemetry receivers in the Susitna River.
FINAL STUDY PLAN SALMON ESCAPEMENT STUDY 9.7
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 24 July 2013
Figure 9.7-2. Fixed-station telemetry receivers in the Middle and Upper Susitna River, 2012–2014.
FINAL STUDY PLAN SALMON ESCAPEMENT STUDY 9.7
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 25 July 2013
Figure 9.7-3. Study interdependencies for Salmon Escapement Study.
STUDY INTERDEPENDENCIES FOR SALMON ESCAPEMENT STUDY (9.7)
Obj. 8 Estimate
Chinook and coho
escapement and
dist. among
tributaries
Obj. 2
Characterize
migration
behavior and
spawning
locations of
tagged salmon
Obj. 3
Characterize
salmon
movement in and
above Devil’s
Canyon
9.11
Fish Passage
Feasibility
(salmon
presence info)
9.15
Analysis of Fish
Harvest
(relative harvest
pressure)
9.13
Aquatic
Resources Access
(salmon in vicinity
of stream
crossings
9.12
Fish Passage Barriers
(ground truth
presence/absence
above barriers)
9.10 Future
Reservoir
Community
(Obj. 3)
Salmon
distribution and
access to habitat
(Q2 2013 –Q4
2014)
Salmon
presence above
the proposed
dam site
(Q2 2013 –Q4
2014)
Abundance by
major tributary
(Q2 2013 –Q4
2014)
Obj. 1 & 2
Travel distance
and spawning
locations of
salmon
9.5 Upper
River
Distribution
9.6 Middle
and Lower
River
Distribution
Salmon
distribution
observations (Q2
2013 –Q2 2015)
Fish tissue
samples
(Q2 2013 –Q2
2015)
9.14
Genetic
Baseline
Study
Genetic structure
of Chinook salmon
(Q4 2014)
9.9
Characterize
Aquatic
Habitats
Habitat
characterization
(Q4 2014)