HomeMy WebLinkAboutCaribou distribution abundance movements section 10.6 2013Alaska Resources Library & Information Services
Susitna-Watana Hydroelectric Project Document
ARLIS Uniform Cover Page
Title:
Caribou distribution, abundance, movements, productivity, and survival
study, Study plan Section 10.6 : Final study plan SuWa 200
Author(s) – Personal:
Author(s) – Corporate:
Alaska Energy Authority
AEA-identified category, if specified:
Final study plan
AEA-identified series, if specified:
Series (ARLIS-assigned report number):
Susitna-Watana Hydroelectric Project document number 200
Existing numbers on document:
Published by:
[Anchorage : Alaska Energy Authority, 2013]
Date published:
July 2013
Published for:
Date or date range of report:
Volume and/or Part numbers:
Study plan Section 10.6
Final or Draft status, as indicated:
Document type:
Pagination:
10 p.
Related work(s):
Pages added/changed by ARLIS:
Notes:
All reports in the Susitna-Watana Hydroelectric Project Document series include an ARLIS-
produced cover page and an ARLIS-assigned number for uniformity and citability. All reports
are posted online at http://www.arlis.org/resources/susitna-watana/
Susitna-Watana Hydroelectric Project
(FERC No. 14241)
Caribou Distribution, Abundance, Movements,
Productivity, and Survival Study
Study Plan Section 10.6
Final Study Plan
Alaska Energy Authority
July 2013
FINAL STUDY PLAN CARIBOU DISTRIBUTION, ABUNDANCE, MOVEMENTS,
PRODUCTIVITY, AND SURVIVAL STUDY 10.6
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 10.6-1 July 2013
10.6. Caribou Distribution, Abundance, Movements, Productivity,
and Survival
On December 14, 2012, Alaska Energy Authority (AEA) filed with the Federal Energy
Regulatory Commission (FERC or Commission) its Revised Study Plan (RSP), which included
58 individual study plans (AEA 2012). Section 10.6 of the RSP described the Caribou
Distribution, Abundance, Movement, Productivity, and Survival Study. This study focuses on
characterizing caribou distribution, movements, population size, productivity, group size, and
density in the Project area through radio telemetry and geospatial anal yses. RSP 10.6 provided
goals, objectives, and proposed methods for data collection regarding caribou.
On February 1, 2013, FERC staff issued its study plan determination (February 1 SPD) for 44 of
the 58 studies, approving 31 studies as filed and 13 with modifications. RSP Section 10.6 was
one of the 31studies approved with no modifications. As such, in finalizing and issuing Final
Study Plan Section 10.6, AEA has made no modifications to this study from its Revised Study
Plan.
10.6.1. General Description of the Proposed Study
This study plan outlines the objectives and methods for characterizing caribou distribution,
movements, population size, productivity, group size, and density in the Project area through
radio telemetry and geospatial analyses. Aerial radio-tracking surveys via fixed-wing aircraft will
be used to monitor seasonal distribution and range use in the study area, including
characterization of calving areas, rutting areas, wintering areas, and migration/movement
corridors. In addition to standard VHF radio collars, satellite-linked GPS collars will be deployed
to evaluate fine-scale spatial distribution and movements of cows and bulls.
This study is a multi-year effort that is being conducted by the Alaska Department of Fish and
Game (ADF&G). ADF&G began the caribou movement study in 2012 by deploying radio
collars. This study supplements ADF&G’s ongoing caribou research in the region by increasing
the sample size of radio-collared cows and by radio-collaring bulls in both the Nelchina and
Delta herds to better delineate the seasonal movements and range use of each herd. Radio collars
were deployed in October 2012 and will be monitored for the remainder of this study.
GPS/satellite collars deployed in October 2012 will be removed in October 2014.
Study Goal and Objectives
The goal of this study is to obtain sufficient population information on caribou to evaluate
Project-related effects on important seasonal ranges, such as calving areas, rutting areas,
wintering areas, and migration/movement corridors.
The study has four specific objectives:
Document seasonal use of and movement through the Project area by both females and
males of the Nelchina caribou herd (NCH) and the Delta caribou herd (DCH).
Assess the relative importance of the Project area to both the NCH and DCH.
Document productivity and survival of caribou using the Project area.
Analyze data from historical caribou studies and synthesize with recent data for the NCH
and DCH, as a continuation of the caribou task of the 2012 study (AEA 2012).
FINAL STUDY PLAN CARIBOU DISTRIBUTION, ABUNDANCE, MOVEMENTS,
PRODUCTIVITY, AND SURVIVAL STUDY 10.6
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 10.6-2 July 2013
10.6.2. Existing Information and Need for Additional Information
The current population objective for the NCH was established to ensure consistently high
sustainable harvest levels for Alaskan hunters (Tobey and Schwanke 2009). ADF&G’s
management objectives for the NCH in Game Management Unit (GMU) 13 and GMU subunit
14B are to maintain a fall population of 35,000 to 40,000 caribou, with minimum ratios of 40
bulls to 100 cows and 40 calves to 100 cows; and to provide for an annual harvest of 3,000 to
6,000 caribou (Tobey and Schwanke 2009). ADF&G’s management objectives for the DCH in
GMU 20A are to maintain sex ratios of at least 30 bulls to 100 cows and at least 6 large bulls to
100 cows; reverse the decline of the herd and increase the midsummer population to 5,000–7,000
caribou; and sustain an annual harvest of 300 to 700 caribou (Seaton 2009).
The caribou study for the original Alaska Power Authority (APA) Susitna Hydroelectric Project
began in 1980 and continued through 1985. The objectives of the study were to determine the
population status of the NCH, delineate subherds, and identify range use, movement patterns,
migration routes, and migration timing (ABR 2011). Three resident subherds were identified and
the proposed reservoir was found to intersect migration routes used by pregnant cows moving to
calving grounds during late April and May and cows and calves moving to summer range during
late June and July (Pitcher 1982). Caribou use of the Project area currently is complicated by
range expansion and mixing of DCH animals with those from the NCH (Seaton 2009).
Caribou range use and movement studies during the early 1980s for the APA Susitna
Hydroelectric Project are insufficient to accurately characterize current caribou use of the Project
area. Since 1985, the number of NCH caribou has increased significantly. The NCH is a
moderately large herd, numbering 40,233 caribou in 2011 (ADF&G, unpublished data), whereas
the DCH is much smaller, numbering 2,985 caribou in 2007 (Seaton 2009). Both the NCH and
the DCH use portions of the Project area extensively. A related change has been increased use of
summer and winter range in the northwestern portion of the NCH range in GMU subunit 13E,
northwest of the Project location. Because the NCH continues to calve in the e astern Talkeetna
Mountains in GMU subunit 13A, south of the Project location, changes in summer and winter
range could mean more caribou will cross through the Project area during seasonal migrations to
and from the calving grounds. Hence, although the existing information suggests that NCH
animals are more likely to cross the inundation zone, it is possible that some DCH animals may
do so as well. The proposed study will elucidate the current movement patterns of both herds.
Current annual monitoring efforts for the NCH and DCH by ADF&G identify general herd
distribution, productivity, and annual survival for the purpose of assessing annual herd trends
and related harvest strategies, but more data are needed to meet the needs of the Project.
Therefore, this study has been designed to provide additional data, much of it at finer temporal
and spatial scales than previously available, to assess potential Project-related impacts and to
help identify potential mitigation measures for caribou in the Project area. Mixing of the two
caribou herds since the mid-1990s in the northern portion of the Project area between the Susitna
River and Butte Lake has been a more recent development that adds a level of complexity to
range use and importance for the two herds (Seaton 2009). In addition, established vegetation
exclosures in the NCH range can be used to monitor abundance of lichens in an ungrazed area
for assessment of range conditions.
Documentation of currently used areas, along with information on the timing, duration, and
proportion of the regional population that uses those areas, can be used to develop any necessary
FINAL STUDY PLAN CARIBOU DISTRIBUTION, ABUNDANCE, MOVEMENTS,
PRODUCTIVITY, AND SURVIVAL STUDY 10.6
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 10.6-3 July 2013
protection, mitigation, and enhance measures, as appropriate. This information also will be
useful for mitigating inadvertent disturbance from unrelated field studies for the Project.
10.6.3. Study Area
The caribou study area will reflect use of the Project area by the NCH and the DCH. The study
area will include most of GMU 13E east of and including Broad Pass (Figure 10.6-1). The study
area also will include drainages emptying into the Upper Susitna River in GMU 13B, as well as a
small portion of northwestern GMU 13A from Kosina Creek east to the Oshetna River. The
study area encompasses the reservoir inundation zone, associated infrastructure, and potential
access and transmission line corridors from the west and the north. Downstream areas in the
Middle Susitna River basin that could be affected by changes in stream flows, temperatures, and
ice conditions that could alter conditions for river crossings traditionally used by caribou will be
included as well. The study area must be somewhat larger than the areas of primary focus,
because of the history of caribou movements in the area and the need to fully evaluate caribou
migration routes and habitat preferences.
10.6.4. Study Methods
ADF&G began a caribou movement study in 2012 by deploying new VHF and satellite-linked
GPS radio collars, with more collars scheduled for deployment in subsequent years of this study.
This study supplements ADF&G’s ongoing caribou research in the region by increasing the
sample size of radio-collared cows and by radio-collaring bulls in both herds to better delineate
the seasonal movements and range use of each herd. In addition, GPS collars will be deployed on
bulls and cows to detect fine-scale movements for both herds. Some captures will occur in the
month of April to target caribou overwintering in the Project area, with additional captures
occurring in October to target migratory caribou.
To address fine-scale movements—both temporally and geographically—at least 60 GPS collars
will be deployed (40–45 on NCH animals and 15–20 on DCH animals). Up to 70 percent of the
GPS collars will be deployed on cows. Considering that the proposed reservoir inundation zone
is primarily used during migration, gathering daily locations with the use of GPS collars is the
only way to ensure that travel corridors and travel patterns are identified accurately. Small
piston-powered (Robinson R-44) helicopters and chemical immobilization techniques will be
used for caribou captures and small fixed-wing aircraft (Piper PA-18 or similar) will be used for
radio-tracking flights.
Due to limited battery life, the GPS collars will need to be removed after two years for retrieval
of all data stored on board; the collars then will be refurbished and redeployed to gather
additional data to further describe movements and range utilization and incorporate annual
differences. All GPS collars eventually will be removed to ensure that all data stored onboard the
collars is retrieved. Standard VHF radio collars will be deployed with the expectation that they
will remain on the animals.
The VHF collars deployed in April 2012 (8 on DCH bulls and 7 on NCH bulls) will be
monitored for the remainder of this study, whereas the GPS collars deployed in May 2012 (4
each on NCH and DCH bulls) will be monitored until the collars are retrieved in April or May
2014 for data downloading and collar refurbishing. Radio collars deployed in October 2012 (55
GPS collars on females and 15 VHF collars on bulls) will be monitored for the remainder of this
FINAL STUDY PLAN CARIBOU DISTRIBUTION, ABUNDANCE, MOVEMENTS,
PRODUCTIVITY, AND SURVIVAL STUDY 10.6
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 10.6-4 July 2013
study, and the GPS collars will be removed in October 2014. Collar failures are not anticipated,
although a small percentage may malfunction, requiring capture and replacement outside of the
schedule outlined.
All existing radio collars deployed on NCH and DCH caribou will be monitored monthly within
the Project area via aerial radio-tracking. During spring and fall migration periods, as well as the
calving season, additional flights will be conducted more frequently (every two weeks).
No net loss is expected to occur for existing herd monitoring programs. For those caribou
currently radio-collared, if radio collars are replaced with GPS collars for this study, then new or
refurbished radio collars will be redeployed on each of these animals at the end of the study.
To investigate seasonal movements and range use by bull caribou, 15 VHF collars and 8 GPS
collars were deployed on bulls of both herds in April and May 2012, supplementing
approximately 80 existing radio collars on NCH cows and 40 existing radio collars on DCH
cows. The female segment represents the reproductive portion of the herd, as well as the leading
edge of seasonal movements, supporting the higher number of collars for cows.
VHF-collared caribou must be located via fixed-wing aircraft. Monthly aerial radio-tracking
flights will provide general documentation of herd distribution and the extent of herd mixing in
the Project area. Additional flights (every two weeks) during spring and fall migrations will
result in more precise documentation of use of the Project area by both herds . The large sample
of radio-collared caribou is necessary to fully evaluate the relative importance of the Project area
in terms of available herd ranges and potential movement corridors. The outlined sample sizes
should be sufficient for an accurate representation of herd-wide movement patterns and range
use.
Locations collected from satellite and GPS collars will be used to evaluate the spatial distribution
and movements of cows and bulls from each herd. Additional locations, reproduction, survival
status, and group size will be documented for each caribou located during scheduled radio-
tracking flights.
Data analysis and visual representation of data will be accomplished using a Geographic
Information System (GIS) running ArcGIS® software. Population estimates based on existing
data will be calculated consistent with the method used to collect the data. Density estimates will
be calculated at a spatial resolution suitable to evaluate potential habitat loss and alteration from
the Project. Telemetry data will be used to delineate seasonal ranges and movement corridors
using techniques such as kernel density estimates (Seaman and Powell 1996) and Brownian
bridge (or similar) movement model techniques (Horne et al. 2007; Sawyer et al. 2009),
depending on the volume and suitability of the data for use with these techniques.
10.6.5. Consistency with Generally Accepted Scientific Practices
ADF&G is the primary agency responsible for monitoring caribou populations in Alaska. The
techniques used to capture, collar, and track caribou in this study have been developed by
ADF&G through decades of experience working with big game species in Alaska. The methods
employed in this study will consist of standard capture, handling, and monitoring techniques for
cow caribou (Adams et al. 1987). In recent years, these techniques also have been used for bull
caribou. All methods will be fully evaluated and compliant with Alaska Interagency Animal Care
FINAL STUDY PLAN CARIBOU DISTRIBUTION, ABUNDANCE, MOVEMENTS,
PRODUCTIVITY, AND SURVIVAL STUDY 10.6
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 10.6-5 July 2013
and Use Committee certification. Standard permits required by the State of Alaska for animal
capture and monitoring are in-hand.
Caribou data will be analyzed according to commonly accepted statistical techniques. Spatial
analyses will employ commonly accepted techniques such as fixed-kernel density estimation
with least-squares cross validation or plug-in bandwidth selection (Seaman and Powell 1996;
Gitzen et al. 2006).
10.6.6. Schedule
This study is a multi-year effort that began with collar deployment and radio-tracking in 2012.
The schedule for 2013–2014 activities is depicted in Table 10.6-1. GPS and VHF radio collars
that were deployed in 2012 will be monitored at least monthly throughout the entire year in 2013
and 2014, except during migration periods in spring (May–June) and fall (August–September),
when they will be tracked more often (every two weeks) to delineate migratory movements in
relation to the Project area. The Initial Study Report will be completed by February 2014 and
will include analyses of data obtained through fall migration 2013, at a minimum. In April 2014,
the GPS/satellite collars deployed in April 2012 will be removed to retrieve the data stored in the
collars for analysis (the collars must be retrieved to obtain all data). In October 2014, the
GPS/satellite collars that were deployed in October 2012 will be removed and the collars
removed in April 2014 will be redeployed (after having been refurbished). The Updated Study
Report will be completed by February 2015 and will include analyses of data obtained through
fall migration 2014, at minimum. Project updates will be provided at Technical Workgroup
meetings, which will be held quarterly in 2013 and 2014.
10.6.7. Relationship with Other Studies
As is depicted below (Figure 10.6-2), the caribou study does not require information inputs from
any other Project studies, although it will benefit from preliminary studies begun in 2012 (AEA
2012), which analyzed historical data from the original APA Susitna Hydroelectric Project
studies in the 1980s. The GIS database of caribou locations from VHF and GPS radio collars will
be used to assess seasonal patterns of habitat use. Output from the caribou study will be used to
inform the Evaluation of Wildlife Habitat Use (Section 10.19) through geospatial analysis by
overlaying location and movement data on the Project habitat map to identify important areas of
seasonal ranges that receive repeated use, movement corridors in relation to the proposed
reservoir and Project infrastructure, and important habitat types (e.g., for which use exceeds
availability). These geospatial analyses, along with results from other studies (e.g., Ice Processes
Study [Section 7.6], Subsistence Study [Section 14.5], Wildlife Harvest Analysis [Section
10.20], Large Carnivores Study [Section 10.8]) will be used in 2015 to assess potential impacts
and to evaluate protection, mitigation, and enhancement measures, as appropriate, during
development of the FERC License Application.
The potential impacts of the Project on caribou may include direct and indirect habitat loss and
alteration or blockage of movement corridors in portions of the range of both the NCH and the
DCH, because animals from either herd may encounter the reservoir inundation zone, access and
transmission line corridors, and other Project facilities. Other potential impacts include changes
in mortality rates that may result from increased subsistence or recreational harvest facilitated by
improved access or from changes in predator populations, and mortality from collisions with
FINAL STUDY PLAN CARIBOU DISTRIBUTION, ABUNDANCE, MOVEMENTS,
PRODUCTIVITY, AND SURVIVAL STUDY 10.6
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 10.6-6 July 2013
vehicles or unstable ice conditions in the impoundment. During the impact assessment that will
be conducted in 2015 for the FERC License Application, data on the distribution, abundance,
productivity, and habitat use of caribou in the study area will be used to assess Project impacts.
Location data will be used to identify movement corridors. Location and abundance data can be
plotted on the wildlife habitat map that will be developed by the Vegetation and Wildlife Habitat
Mapping Study (Section 11.5) to identify important caribou habitats. Direct habitat loss can be
calculated through geospatial analysis by overlaying the impoundment, access and transmission
facility “footprints”, and related proposed Project infrastructure onto the habitat map and
evaluating the loss of important caribou habitats. Indirect habitat loss and avoidance impacts can
be estimated by applying various buffer distances, as determined from available information on
the anticipated effects of similar projects or activities on caribou. Similarly, movement corridors
can be compared to Project features to assess the extent to which movements and distribution
may be affected. ADF&G harvest data will be used to establish baseline harvest levels and to
monitor changes in harvest that may result from improved access. In this way, t he GIS analysis
will be combined with information from the literature to estimate the geographic extent,
frequency, duration, and magnitude of Project effects on caribou populations.
10.6.8. Level of Effort and Cost
This study is a multi-year effort that is being conducted by ADF&G. The estimated cost of the
study through 2014 is approximately $610,000.
10.6.9. Literature Cited
ABR. 2011. Wildlife data-gap analysis for the proposed Susitna-Watana Hydroelectric Project.
Draft report, August 16, 2011. Report for the Alaska Energy Authority by ABR, Inc.—
Environmental Research and Services, Fairbanks, Alaska. 114 pp.
Adams, L. G., P. Valkenburg, and. J. L. Davis. 1987. Efficacy of carfentanil citrate and naloxone
for field immobilization of Alaskan caribou. Proceedings of the North American Caribou
Workshop 3: 167–168.
AEA (Alaska Energy Authority). 2012. W-S1: Wildlife habitat use and movement study for the
Susitna–Watana Hydroelectric Project, FERC Project No. 14241. Draft final version
(March 21, 2012). Alaska Energy Authority, Anchorage.
Gitzen, R. A., J. J. Millspaugh, and B. J. Kernohan. 2006. Bandwidth selection for fixed -kernel
analysis of animal utilization distributions. Journal of Wildlife Management 70: 1334–
1344.
Horne, J. S., E. O. Garton, S. M. Drone, and J. S. Lewis. 2007. Analyzing animal movements
using Brownian bridges. Ecology 88: 2354–2363.
Pitcher, K. W. 1982. Susitna Hydroelectric Project, Phase I final report, Big game studies, Vol.
IV—Caribou. Report prepared by Alaska Department of Fish and Game, Anchorage, for
Alaska Power Authority, Anchorage. 43 pp.
Sawyer, H., M. J. Kauffman, R. M. Nielson, and J. S. Horne. 2009. Identifying and prioritizing
ungulate migration routes for landscape-level conservation. Ecological Applications 19:
2016–2025.
FINAL STUDY PLAN CARIBOU DISTRIBUTION, ABUNDANCE, MOVEMENTS,
PRODUCTIVITY, AND SURVIVAL STUDY 10.6
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 10.6-7 July 2013
Seaman, D. E., and R. A. Powell. 1996. An evaluation of the accuracy of kernel density
estimators for home range analysis. Ecology 77: 2075–2085.
Seaton, C. T. 2009. Unit 20A caribou management report. Pages 122–135 in P. Harper, editor.
Caribou management report of survey and inventory activities, 1 July 2006–30 June
2008. Project 3.0, Alaska Department of Fish and Game, Juneau.
Tobey, R. W., and R. A. Schwanke. 2009. Units 13 and 14B caribou management report. Pages
83–98 in P. Harper, editor. Caribou management report of survey and inventory
activities, 1 July 2006–30 June 2008. Project 3.0, Alaska Department of Fish and Game,
Juneau.
FINAL STUDY PLAN CARIBOU DISTRIBUTION, ABUNDANCE, MOVEMENTS,
PRODUCTIVITY, AND SURVIVAL STUDY 10.6
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 10.6-8 July 2013
10.6.10. Tables
Table 10.6-1. Schedule for implementation of the caribou study.
Activity
2012 2013 2014 2015
4 Q 1 Q 2 Q 3 Q 4 Q 1 Q 2 Q 3 Q 4 Q 1 Q
Deployment of GPS/satellite and VHF
collars in October 2012, with monitoring at
least monthly
Monitor radio collars every two weeks
during migration periods
Initial Study Report, including data obtained
through fall migration in 2013 Δ
Remove GPS collars deployed in April 2012
Remove satellite collars deployed in
October 2012 and deploy refurbished GPS
collars removed in April 2014
Monitoring, at least monthly, of GPS collars
deployed in October 2014
Updated Study Report, including telemetry
data obtained during fall migration in 2014 ▲
Legend:
Planned Activity
Δ Initial Study Report
▲ Updated Study Report
FINAL STUDY PLAN CARIBOU DISTRIBUTION, ABUNDANCE, MOVEMENTS,
PRODUCTIVITY, AND SURVIVAL STUDY 10.6
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9 July 2013
10.6.11. Figures
Figure 10.6-1. Caribou study area.
FINAL STUDY PLAN CARIBOU DISTRIBUTION, ABUNDANCE, MOVEMENTS,
PRODUCTIVITY, AND SURVIVAL STUDY 10.6
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 10 July 2013
STUDY INTERDEPENDENCIES FOR CARIBOU STUDY
Tracking of VHF & GPS
radio collars for data on
seasonal distribution,
movements, productivity,
survival, habitat use
Evaluation of
Wildlife Habitat Use
(Section 10.19)
GIS database of caribou
locations with reproduction,
survival, and habitat-use
attributes
(4Q–2013 & 4Q–2014)
Figure 10.6-2. Interdependencies for caribou study.