HomeMy WebLinkAboutAnalysis of fish harvest in and downstream section 9.15 2013Alaska Resources Library & Information Services
Susitna-Watana Hydroelectric Project Document
ARLIS Uniform Cover Page
Title:
Analysis of fish harvest in and downstream of the Susitna-Watana
Hydroelectric Proeject [sic] area, Study plan Section 9.15 : Final study plan SuWa 200
Author(s) – Personal:
Author(s) – Corporate:
Alaska Energy Authority
AEA-identified category, if specified:
Final study plan
AEA-identified series, if specified:
Series (ARLIS-assigned report number):
Susitna-Watana Hydroelectric Project document number 200
Existing numbers on document:
Published by:
[Anchorage : Alaska Energy Authority, 2013]
Date published:
July 2013
Published for:
Date or date range of report:
Volume and/or Part numbers:
Study plan Section 9.15
Final or Draft status, as indicated:
Document type:
Pagination:
14 p.
Related work(s):
Pages added/changed by ARLIS:
Notes:
All reports in the Susitna-Watana Hydroelectric Project Document series include an ARLIS-
produced cover page and an ARLIS-assigned number for uniformity and citability. All reports
are posted online at http://www.arlis.org/resources/susitna-watana/
Susitna-Watana Hydroelectric Project
(FERC No. 14241)
Analysis of Fish Harvest in and Downstream of the
Susitna-Watana Hydroelectric Proeject Area
Study Plan Section 9.15
Final Study Plan
Alaska Energy Authority
July 2013
FINAL STUDY PLAN ANALYSIS OF FISH HARVEST IN AND DOWNSTREAM OF THE
SUSITNA-WATANA HYDROELECTRIC PROJECT AREA 9.15
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.15-1 July 2013
9.15. Analysis of Fish Harvest in and Downstream of the Susitna-
Watana Hydroelectric Project Area
On December 14, 2012, Alaska Energy Authority (AEA) filed with the Federal Energy
Regulatory Commission (FERC or Commission) its Revised Study Plan (RSP), which included
58 individual study plans (AEA 2012). Section 9.15 of the RSP described the Analysis of Fish
Harvest In and Downstream of the Susitna-Watana Hydroelectric Project Area. This section
focuses on compiling and analyzing baseline information on the harvests of resident and
anadromous fishes in and downstream of the proposed Project area to understand the potential
for Project construction and operation to alter harvest levels and opportunity. RSP 9.15 provided
goals, objectives, and proposed methods for data collection regarding the analysis of these fish
harvests.
On February 1, 2013, FERC staff issued its study plan determination (February 1 SPD) for 44 of
the 58 studies, approving 31 studies as filed and 13 with modifications. RSP Section 9.15 was
one of the 31 studies approved with no modifications. As such, in developing the Final Study
Plan Section 9.15, AEA has made no modifications to this study from its Revised Study Plan.
9.15.1. General Description of the Proposed Study
Information from this fish harvest study will be used in combination with other studies to inform
the licensing process by analyzing baseline harvest data from the Project area downstream to
where the Susitna River joins Upper Cook Inlet and into the marine waters of the Upper Cook
Inlet commercial fisheries management area (Figure 9.15-1). This study will provide a basis for
assessing impacts on fisheries resources and developing protection, mitigation, and enhancement
measures, if necessary.
Study Goals and Objectives
The goal of this study is to compile and analyze baseline information on the harvests of resident
and anadromous fishes in and downstream of the proposed Project area to understand the
potential for Project construction and operation to alter harvest levels and opportunity. This study
has two primary objectives:
1. Describe baseline harvest levels and harvest locations for commercial, sport, personal
use, and subsistence fisheries for Susitna-River-origin resident and anadromous fish.
2. Describe the potential for the Project to alter harvest levels and opportunities on Susitna-
River-origin resident and anadromous fish based on potential Project-induced changes in
fish abundance and distribution from flow- and habitat-related changes as estimated from
other Project studies.
9.15.2. Existing Information and Need for Additional Information
The Alaska Department of Fish and Game (ADF&G) documents legal catches from commercial,
sport, personal use, and subsistence fisheries. Fishing effort and harvest success data are
collected annually by fishery, management area, district, subdistrict, and in some cases by
smaller statistical harvest reporting areas. Historic harvest statistics are stored by ADF&G in
statewide databases.
FINAL STUDY PLAN ANALYSIS OF FISH HARVEST IN AND DOWNSTREAM OF THE
SUSITNA-WATANA HYDROELECTRIC PROJECT AREA 9.15
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.15-2 July 2013
9.15.2.1. Commercial Fisheries
The Susitna River watershed is within the Upper Cook Inlet Management Area (UCIMA) for
commercial fisheries. Commercial salmon fisheries in the UCIMA target salmon stocks bound
for the major river systems of Cook Inlet, including the Susitna River. Salmon are harvested
during seasons and according to regulations established by the Alaska Board of Fisheries. The
ADF&G Division of Commercial Fisheries, based in Soldotna, monitors salmon returns in Cook
Inlet and sets fishing periods based on the perceived strength of the returns to achieve
escapement goals for the major rivers of the area. The UCIMA includes central and northern
districts (Figure 9.15-1), each being further divided into subdistricts (Shields and Dupuis 2012).
Two commercial gear types are permitted in the limited entry commercial fishery: drift gillnets
(Central District only) and set gillnets (allowed in portions of both districts). Commercial
harvests are recorded at the time of sale on a fish ticket, which includes the date, location code
(statistical area), and the number and pounds of each species of salmon delivered. These data are
stored in a statewide fish ticket database.
Five species of Susitna River salmon are commercially harvested in Upper Cook Inlet: Chinook
(Oncorhynchus tshawytscha), sockeye (O. nerka), chum (O. keta), pink (O. gorbuscha), and
coho salmon (O. kisutch). Sockeye salmon make up the largest component of the harvest and
commercial value. Harvest data are summarized and reported annually by the ADF&G Division
of Commercial Fisheries (Shields and Dupuis 2012). The ADF&G Gene Conservation
Laboratory has successfully used genetic mixed stock analysis techniques to identify stock-of-
origin in commercial fishery catches such that the contribution of Susitna River-origin sockeye
salmon can be estimated (Barclay et al. 2010). Efforts are underway to develop the baseline and
resolution for other salmon species.
Eulachon (Thaleichthys pacificus), also known as smelt or hooligan, are harvested commercially
in the UCIMA (Shields and Dupuis 2012; Shields 2005, 2010). Managed under the Cook Inlet
Smelt Fishery Management Plan (5 AAC 21.505), the fishery has a harvest cap of 100 tons.
Harvesters use dip nets, and a majority of the harvest is taken in the vicinity of the Susitna River
delta. Harvest statistics have been reported since 1978; the 2011 season was the first year in
which the harvest cap was reached (Shields and Dupuis 2012).
9.15.2.2. Sport Fisheries
The Susitna watershed lies within the Northern Cook Inlet Management Area (NCIMA) (Figure
9.15-2) established for the management of recreational fisheries. For the purposes of harvest
reporting the NCIMA is divided into four subunits:
• Knik Arm Management Unit lying south of Willow Creek and east of the Susitna River.
• Eastside Susitna Management Unit including all waters of the Upper Susitna River above
the Chulitna River to and including the Oshetna River.
• Westside Susitna Management Unit including the Chulitna and Yentna rivers.
• West Cook Inlet Unit including freshwater drainages entering Cook Inlet to the west of
the Susitna River mouth (Figure 9.15-2).
Sport fisheries in the NCIMA are managed by the ADF&G Division of Sport Fisheries office in
Palmer. The Statewide Harvest Survey (SWHS) annual postal survey of sport fish license holders
is the primary method used by ADF&G to compile harvest estimates for NCIMA sport fisheries
FINAL STUDY PLAN ANALYSIS OF FISH HARVEST IN AND DOWNSTREAM OF THE
SUSITNA-WATANA HYDROELECTRIC PROJECT AREA 9.15
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.15-3 July 2013
(Jennings et al. 2007). Sport fishing harvest and effort by species have been estimated and
reported annually for the four NCIMA management units since 1977.
Sport fisheries in the NCIMA target the five species of Susitna River salmon, with coho salmon
and Chinook salmon making up the largest contributions to the harvest (Jennings et al. 2007).
Other species taken in the sport fishery, ordered by amount harvested, include northern pike
(Esox lucius), rainbow trout (O. mykiss), Arctic grayling (thymallus arcticus), lake trout
(Salvelinus namaycush), Dolly Varden (S. malma), burbot (Lota lota), round whitefish
(Prosopium cylindraceum), and humpback whitefish (Coregonus clupeaformis) (Jennings et al.
2007).
9.15.2.3. Personal Use Fisheries
Three personal use fisheries currently occur within the NCIMA:
• A sockeye salmon dip net fishery at Fish Creek located in Knik Arm.
• A dip net fishery for Alaska residents 60 years or older at the Beluga River (to the west of
the Susitna River mouth).
• A eulachon fishery in the Lower Susitna River (Oslund and Ivey 2010).
Participants in these fisheries obtain a permit from ADF&G and are required to record daily
harvest information on the permit. Permits are returned to ADF&G at the end of the season.
Personal use harvest data are reported annually in ADF&G annual management reports (for
example, Ivey et al. [2009]).
9.15.2.4. Subsistence Fisheries
Subsistence fishing regulations in the Susitna River watershed are complex and restrictive. A
portion of the watershed falls within a “nonsubsistence area” defined under the Alaska
Administrative Code (AAC) 5 AAC 99.015 (3). Trout, char, grayling, and burbot may not be
taken for subsistence in fresh water (5 AAC 01.575. (c)). The only subsistence salmon fishery
authorized within the Susitna watershed is a fishwheel fishery on the upper Yentna River near
the community of Skwentna (5 AAC 01.593). A subsistence gillnet fishery is authorized in the
Tyonek drainage for whitefish (5 AAC 01.580), and smelt may be taken in fresh and salt water
(5 AC 01.599). A coastal set gillnet subsistence fishery operates near the community of Tyonek
in Northern Cook Inlet, which targets salmon returning to the Susitna and other river systems of
northern Cook Inlet. Educational subsistence fisheries are permitted on the east side of the
Central District between Kenai and Anchor Point.
Subsistence salmon harvest data are reported annually in ADF&G annual fishery management
reports (for example Oslund and Ivey 2010, and Shields and Dupuis 2012) and in the Alaska
subsistence salmon fisheries annual reports (for example, Fall et al. 2011). Additional data have
been gathered in targeted studies (for example, Fall and Foster 1987). Historic subsistence
harvest data are stored in the Alaska Subsistence Fisheries Database (ASFDB) managed by the
ADF&G Division of Subsistence in Anchorage (Caylor and Brown 2006). Harvest data for non-
salmon species may not be regularly reported.
FINAL STUDY PLAN ANALYSIS OF FISH HARVEST IN AND DOWNSTREAM OF THE
SUSITNA-WATANA HYDROELECTRIC PROJECT AREA 9.15
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.15-4 July 2013
9.15.2.5. Additional Information Needs
To assess potential Project effects on harvest rates, it is necessary to draw upon other studies that
are designed to estimate abundance and distribution of the various fish stocks in the Susitna
River system. Existing information includes fish spatial and temporal distribution and relative
abundance information from recent and early 1980s studies. The Aquatic Resources Data Gap
Analysis (HDR 2011) and the Susitna-Watana Hydroelectric Project Pre-Application Document
(AEA 2011) summarized existing information and identified data gaps for adult salmon, resident
and rearing fish, and for subsistence resources (Northern Land Research, Inc. 2011). In recent
years, ADF&G has conducted adult salmon (sockeye, coho, and chum salmon) spawning
distribution and abundance studies in the Susitna River (e.g., Yanusz et al. 2011, Merizon et al.
2010). In 2012, ADF&G expanded its scope to include Chinook and pink salmon. Concurrent
studies to be conducted as part of the licensing process for the Project include salmon
escapement and run apportionment, fish distribution and abundance in the Susitna River,
characterization of aquatic habitats in the Susitna River, and subsistence use.
9.15.3. Study Area
The study area includes the Susitna River from its mouth upstream to and including the Oshetna
River (river mile [RM] 233.4). The study area includes tributaries that are connected to the
mainstem of the Susitna River and marine waters of Upper Cook Inlet where anadromous fish
species originating from the Susitna River are intercepted in commercial fisheries north of the
latitude of Anchor Point (59° 46.15’ N. lat.).
9.15.4. Study Methods
Baseline data on commercial, sport, personal use, and subsistence harvests of resident and
anadromous fish in the Project area and other potentially affected areas downstream of the
Project will be gathered and synthesized. Specific tasks include compilation and apportionment
of ADF&G commercial harvest records, compilation of harvest and effort from sport fisheries,
compilation of harvest and effort from personal use fisheries, compilation of subsistence harvest
data, and evaluation of potential project effects. ADF&G opens and closes fishing areas each
year by issuing emergency orders. These orders are necessary to achieve escapement goals for
the various salmon returns to the Cook Inlet area as well as adhering to regulatory directives for
allocation of harvest between user groups. To minimize the effect that emergency order closures
may have on a given year, harvest data will be averaged over a 20-year time period.
These data will be used in combination with the results of fish abundance studies conducted as
part of Project licensing to assess potential Project impacts; further, these data will feed into
analyses to be completed by recreation, socioeconomic and subsistence study teams. Specific
methods are detailed below.
9.15.4.1. Compilation and Apportionment of ADF&G Commercial Harvest Records
Evaluating potential Project effects on commercially harvested fish species is a two-step process
to identify the following: (1) how many Susitna River fish are harvested in the area’s commercial
fisheries, and (2) how many of those fish use mainstem Susitna River habitats that have the
potential to be affected by the Project.
FINAL STUDY PLAN ANALYSIS OF FISH HARVEST IN AND DOWNSTREAM OF THE
SUSITNA-WATANA HYDROELECTRIC PROJECT AREA 9.15
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.15-5 July 2013
Investigators will contact ADF&G Commercial Fisheries staff in area and regional offices to
better understand the spatial and temporal resolution of commercial harvest records in the
UCIMA. Harvest statistics for each of the salmon species commercially harvested in the UCIMA
are stratified spatially and temporally and are reported annually (Shields and Dupuis 2012).
Investigators will compile a minimum of 20 years of harvest and effort statistics from the
ADF&G statewide fish ticket database. Data will be requested at the smallest geographic
reporting units (statistical areas) and time strata. The number of fish and pounds harvested by
species, by day, and by harvest area will be compiled, and trends will be noted. Minimum,
maximum, and mean harvest statistics will be calculated over the 20-year period. These data
represent a mixture of stocks returning to a combination of river systems draining into Upper
Cook Inlet. A review of available genetic stock identification studies will be used to estimate the
proportion of Susitna River stocks in the harvest mixtures. Genetic stock composition data are of
higher resolution for sockeye salmon (Barclay et al. 2010) than for other species, though some
progress has been made apportioning chum and coho salmon stocks (Merizon et al. 2010).
Species that lack sufficient genetic data for run apportionment will be assessed based on the best
available geographic distribution and timing information from telemetry studies, escapement
counts, and harvest reports.
Commercial harvest data from the eulachon fishery will be requested from the state database at
the smallest temporal strata that will produce meaningful interpretation. Because of low
participation, broad time strata may be required to prevent the identification of individual
fishermen. Because the eulachon fishery takes place at the Susitna River mouth, all reported
harvest will be assumed to represent stocks potentially affected by the Project.
9.15.4.2. Compilation of Harvest and Effort from Sport Fisheries
Sport fishery harvest and effort data for the 13 species identified in Section 9.15.2 will be
compiled at the finest geographic resolution available for freshwater fisheries in the Susitna
watershed. Catch, harvest, and angler-day information will be compiled for a minimum of 20
years, and minimum, maximum, and mean values calculated by geographic area. Sources of
information will include annual management reports from the ADF&G Sport Fish Division (e.g.,
Ivey et al. 2009) and from statewide harvest reports (e.g., Jennings et al. 2007). ADF&G
Division of Sport Fish Division staff will be interviewed to better interpret the data available
from the SWHS, and to uncover whether focused creel surveys have been conducted in select
Susitna tributaries. Geographic harvest reporting areas best conforming to the area of potential
Project effects will be selected from the SWHS data. In general, SWHS estimates from smaller
fisheries with low participation are less accurate than those of larger fisheries (Mills and Howe
1992). If the fishery size or level of participation is too small to be adequately assessed by the
SWHS, qualitative information on angler success and participation will be obtained by
interviewing guides, outfitters, fishery participants, and lodge owners operating in the Upper
Susitna.
9.15.4.3. Compilation of Harvest and Effort from Personal Use Fisheries
Harvest and effort data will be compiled for the Fish Creek and Beluga River personal use
salmon fisheries. Sources of information will include annual management reports from the
ADF&G Sport Fish Division, for example Ivey et al. (2009). These fisheries target stocks
returning to a number of river systems including the Susitna River; hence, the likelihood of
FINAL STUDY PLAN ANALYSIS OF FISH HARVEST IN AND DOWNSTREAM OF THE
SUSITNA-WATANA HYDROELECTRIC PROJECT AREA 9.15
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.15-6 July 2013
detecting significant Project effects is low. Regardless, harvest and effort data will be compiled
for the eulachon fishery at the mouth of the Susitna River from permit return data and annual
reports produced by ADF&G.
9.15.4.4. Compilation of Subsistence Harvest Data
All Cook Inlet subsistence fisheries will be reviewed. However, due to their proximity to the
Susitna River watershed it is likely that the only fisheries that would have any potential linkage
to the Susitna Project are the Tyonek gillnet fishery and the Yentna fishwheel fishery. A
minimum of 20 years of harvest and effort data will be compiled for the Tyonek Subdistrict
subsistence gillnet fishery from the ASFDB and/or available reported harvest data. Because this
is a marine fishery, an estimate will need to be made about the proportion of Susitna River stocks
in the harvests. The estimate will use available genetic stock identification information (e.g.,
Barclay et al. 2010) and other sources such as run timing and proximity to other salmon systems.
Harvest statistics will be compiled for the fishwheel fishery on the upper Yentna River near the
community of Skwentna.
9.15.4.5. Evaluation of Potential Project Effects
Evaluating the potential for flow- and habitat-related changes to alter harvest rates for Susitna
River fishery resources will require an integration of the results from multiple studies (Figure
9.15-3). Potential effects will differ based on species, fishery type, fishery location, life history
and periodicity of affected species, and the magnitude of flow and habitat effects and other
Project-related changes. The following studies initiated in 2012 and/or conducted during 2013–
2014 will provide information useful for evaluating effects on fish harvest and opportunity.
• The River Flow Routing and Instream Flow Models Data Collection initiated in 2012
will predict stage versus discharge relationships for approximately 100 transects in the
mainstem of the Susitna River below the proposed reservoir.
• The Aquatic Habitat and Geomorphic Mapping of the Middle River Study will provide a
comparison of the habitat mapping conducted in the 1980s with habitat mapping
developed at similar discharges in 2012. One of the intents of the Geomorphic Mapping
Study is to help address the potential effect of Project operations on the stability of
tributary mouths and access to tributaries within the Middle Susitna River. It is also
intended to provide baseline information to evaluate the influence of Project-induced
changes to mainstem water surface elevations in July through September on adult salmon
access to upland sloughs, side sloughs, and side channels used for spawning.
• The Fish Passage Barriers Study (Section 9.12) will help inform how Project-induced
changes to mainstem water surface elevations in July through September influence adult
salmon access to upland sloughs, side sloughs, and side channels.
• The Upper Susitna River Fish Distribution and Habitat Study will quantify the amount of
riverine habitat likely to be lost due to inundation and interruption of fish passage.
• The Fish Distribution and Abundance Studies in the Upper, Middle, and Lower Susitna
River will provide necessary information on fish abundance by habitat type.
FINAL STUDY PLAN ANALYSIS OF FISH HARVEST IN AND DOWNSTREAM OF THE
SUSITNA-WATANA HYDROELECTRIC PROJECT AREA 9.15
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.15-7 July 2013
• The Eulachon Distribution and Abundance Study (Section 9.16) will estimate the
abundance of eulachon in the Lower Susitna River.
• The Susitna-Watana Instream Flow Study (ISF) is focused on development of
macrohabitat-specific models that can reliably estimate flow-habitat response patterns for
different species and life stages of fish and other aquatic biota.
• The Salmon Escapement and Run Apportionment Study will provide a watershed
perspective on the salmon returns to the Susitna River and apportion runs to the major
tributaries (Yentna River, Chulitna River, Talkeetna River, etc.) as well as the mainstem
areas potentially affected by the Project.
A synthesis of the results from these studies will be required to estimate Project effects on
fisheries as a proportion of the returns to the entire Susitna watershed. It is important to note that
there will be high inter-annual variability in fish abundance estimates used to quantify potential
impacts; in some cases the error associated with these estimates may exceed harvest levels for a
particular fishery. For this reason, potential changes to harvest level and opportunity will be
expressed as a range.
Potential effects to marine fisheries
For commercial salmon fisheries in the Northern and Central Districts and the Tyonek
subsistence salmon fishery, estimates of harvest rates for Susitna River stocks based on genetic
stock allocation will be analyzed to quantify potential effects on harvests. Northern District set
gillnet fisheries likely harvest a higher proportion of Susitna River salmon than Central District
drift and set gillnet fisheries. Thus, effects will need to be assessed by district and on a gear type
basis, taking the timing of fishery openings and closures into account. Outputs from the flow
routing model and riverine process models developed as part of the instream flow studies will
provide simulations of Project effects under various proposed operational scenarios. These
localized effects from the models will need to be put into the context of population level of
harvested species within the Susitna River system and the mixtures of Susitna River and non-
Susitna River stocks in the marine fisheries in the Northern and Central districts of the UCIMA.
Potential impacts will be analyzed over the 20-year record of harvest.
Potential effects to eulachon fisheries
Eulachon harvested in the commercial and personal use fisheries operating in the mouth of the
Susitna River will be treated as a single stock in the effects analysis. Abundance estimates
generated from the Eulachon Distribution and Abundance Study of the RSP, coupled with the
reported harvest information, will be used to estimate exploitation rates for the years that
abundance data are available. Quantitative estimates of Project effects resulting from proposed
operational scenarios will be obtained from the flow routing model and riverine process models
developed as part of the instream flow studies.
Potential effects to sport fisheries
Effects on sport fisheries will be analyzed spatially based on the four broad reporting areas and
on a species-by-species basis within the Susitna River system. Potential Project effects within
the reservoir and tributaries upstream of the proposed dam site will be assessed by studies
conducted in 2013–2014 as part of the Project licensing process, i.e., the Fish Distribution and
Abundance Study, the Aquatic Habitat Study, the Fish Passage Study, and the Instream Flow
FINAL STUDY PLAN ANALYSIS OF FISH HARVEST IN AND DOWNSTREAM OF THE
SUSITNA-WATANA HYDROELECTRIC PROJECT AREA 9.15
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.15-8 July 2013
Study and related operational models. Analysis will be conducted on a species-by-species basis
taking into account migratory versus non-migratory and other life history characteristics. The
future Watana Reservoir Fish Community Study will provide information on potential sport
fishing opportunities anticipated in the proposed Project reservoir.
Middle and Lower River sport fisheries will be analyzed spatially and on a species-by-species
basis. Outputs from the flow routing model and riverine process models developed as part of the
instream flow studies will provide quantitative results of Project effects under various proposed
operational scenarios. These localized effects will need to be put into the context of the species
populations within the major tributaries of the Susitna River system to estimate potential effects
on harvest opportunity and catch rates.
9.15.5. Consistency with Generally Accepted Scientific Practices
This study plan was developed by fisheries scientists in consultation with ADF&G and the U.S.
Fish and Wildlife Service (USFWS). The data used in this study have been and will be collected
by ADF&G as part of its annual harvest assessments and rely upon regionally accepted methods
for estimation of harvest.
9.15.6. Schedule
Harvest and effort statistics will be compiled in 2013 along with a synthesis of the best available
genetic apportionment of salmon stocks harvested in commercial and subsistence fisheries
(Table 9.15-1). Analyses of potential Project-related effects on harvest levels and opportunity
will be conducted in 2014 as results from other Project studies become available. Initial and
Updated Study Reports discussing actions taken to date will be issued within 1 and 2 years, ,
respectively, of FERC’s Study Plan Determination (i.e., February 1, 2013).
9.15.7. Relationship with Other Studies
The Fish Harvest Study will interrelate with eight other AEA Project studies (Figure 9.15-3).
Evaluating the potential for flow- and habitat-related changes to alter harvest rates for Susitna
River fishery resources will require an integration of the results from multiple studies. The River
Flow Routing and Instream Flow Study (Section 8.0) will predict stage versus discharge
relationships for approximately 100 transects in the mainstem of the Susitna River below the
proposed reservoir. The Aquatic Habitat (Section 9.9) and Geomorphic Mapping (Section 6.0)
studies will provide a comparison of the habitat mapping conducted in the 1980s with habitat
mapping developed at similar discharges in 2012. One of the intents of the Geomorphic Mapping
Study is to help address the potential effect of Project operations on the stability of tributary
mouths and access to tributaries within the Middle Susitna River. It is also intended to provide
baseline information to evaluate the influence of Project-induced changes to mainstem water
surface elevations in July through September on adult salmon access to upland sloughs, side
sloughs, and side channels used for spawning. The Fish Passage Barriers Study (Section 9.12)
will help inform how Project-induced changes to mainstem water surface elevations may
influence adult salmon access to upland sloughs, side sloughs, and side channels. The Aquatic
Habitat Study (Section 9.9) will quantify the amount of riverine habitat likely to be lost due to
inundation and interruption of fish passage. The Lower/Middle (Section 9.5) and Upper (Section
9.6) Susitna River Fish Distribution and Abundance will provide necessary information on fish
FINAL STUDY PLAN ANALYSIS OF FISH HARVEST IN AND DOWNSTREAM OF THE
SUSITNA-WATANA HYDROELECTRIC PROJECT AREA 9.15
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.15-9 July 2013
abundance by habitat type. The Eulachon Distribution and Abundance Study (Section 9.16) will
estimate the abundance of eulachon in the Lower Susitna River. The Susitna-Watana Instream
Flow Study (ISF, Section 8.0) is focused on development of macrohabitat-specific models that
can reliably estimate flow-habitat response patterns for different species and life stages of fish
and other aquatic biota. The Escapement Study (Section 9.7) will provide a watershed
perspective on the salmon returns to the Susitna River and apportion runs to the major tributaries
(Yentna River, Chulitna River, Talkeetna River, etc.) as well as the mainstem areas potentially
affected by the Project. A synthesis of the results from these studies will be required to estimate
Project effects on fisheries as a proportion of the returns to the entire Susitna watershed. Results
of the Fish Harvest Study will be used as output to inform the Recreational Resources Study
(Section 12.5).
The flow of information into the Fish Harvest Study is anticipated to occur over the two-year
study period through an iterative process. Relevant analyses of potential Project effects, from
studies described above, will be disseminated from the Aquatic Resources and Instream Flow
Programs to the Fish Harvest Technical team. To maximize communication among the Fish
Study Programs, study leads will participate in internal meetings where preliminary data will be
presented and implications to fish production will be discussed. These discussions will occur to a
limited degree in Q1 2014 and more significantly in Q4 of 2014, feeding directly into study
results.
9.15.8. Level of Effort and Cost
This study will focus on compiling and analyzing existing harvest data and new data collected
from other fish, habitat, subsistence, and recreational studies. This study will be primarily a
desktop exercise. It is estimated that this study will cost approximately $200,000.
9.15.9. Literature Cited
AEA (Alaska Energy Authority). 2011. Pre-application Document: Susitna-Watana
Hydroelectric Project FERC Project No. 14241. December 2011. Prepared for the
Federal Energy Regulatory Commission, Washington, D.C.
Barclay, A. W., C. Habicht, W. D. Templin, H. A. Hoyt, T. Tobias and T. M. Willette. 2010.
Genetic stock identification of Upper Cook Inlet sockeye salmon harvest, 2005–2008.
Alaska Department of Fish and Game, Fishery Manuscript No. 10-01.
Caylor, D.A. and L.A. Brown. 2006. Alaska subsistence fisheries database Version 3.5 for
Microsoft Access. Alaska Department of Fish and Game, Division of Subsistence,
Juneau, Alaska.
Fall, J. A. and D. J. Foster. 1987. Fish and game harvest and use in the Middle Susitna Basin:
the results of a survey of residents of the road-connected areas of Game Management
Units 14B and 16A, 1986. Technical Paper No. 143. Alaska Department of Fish and
Game, Division of Subsistence, Juneau, Alaska.
Fall, J.A., C. Brown, N. Braem, J. Simon, W. Simeone, D. Holen, L. Naves, T. Lemons, and T.
Krieg. 2011. Alaska subsistence salmon fisheries 2008 annual report. Technical Paper
No. 359. Alaska Department of Fish and Game, Subsistence Division. Anchorage,
Alaska.
FINAL STUDY PLAN ANALYSIS OF FISH HARVEST IN AND DOWNSTREAM OF THE
SUSITNA-WATANA HYDROELECTRIC PROJECT AREA 9.15
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.15-10 July 2013
HDR Alaska, Inc. 2011. Aquatic resources data gap analysis. Draft. Prepared for Alaska Energy Authority. July 20, 2011.
Ivey, S., C. Brockman, and D. Rutz. 2009. Area management report for the recreational fisheries
of Northern Cook Inlet, 2005 and 2006. Alaska Department of Fish and Game, Fishery
Management Report No. 09-27, Anchorage.
Jennings, G.B., K. Sundet, and A. Bingham. 2007. Participation, catch, and harvest in Alaska
sport fisheries during 2004. Fisheries Data Series No. 07-40. Alaska Department of Fish
and Game, Division of Sport Fisheries, Anchorage, Alaska.
Merizon, R. A., R. J. Yanusz, D. J. Reed, and T. R. Spencer. 2010. Distribution of spawning
Susitna River chum Oncorhynchus keta and coho O. kisutch salmon, 2009. Alaska
Fishery Data Series No. 10-72. Department of Fish and Game, Divisions of Sport and
Fish and Commercial Fisheries.
Mills, M.J. and A. Howe. 1992. An evaluation of estimates of sport fish harvest from the Alaska
statewide mail survey. Alaska Department of Fish and Game, Special Publication No. 92-
20, Anchorage.
Northern Land Research, Inc. 2011. Watana hydroelectric project subsistence data gap analysis.
Prepared for the Alaska Energy Authority, Fairbanks. 87 pp.
Oslund, S. and S. Ivey. 2010. Recreational fisheries of northern Cook Inlet, 2009—2010: A
report to the Alaska Board of Fisheries, February 2011. Alaska Department of Fish and
Game, Fishery Management Report No. 10-50, Anchorage.
Shields, P. 2005. Upper Cook Inlet commercial herring and smelt fisheries through 2004. Alaska
Department of Fish and Game, Special Publication No. 05-14, Anchorage, Alaska.
Shields, P. 2010. Upper Cook Inlet commercial fisheries annual management report, 2011.
Alaska Department of Fish and Game, Fishery Management Report No. 12-25,
Anchorage.
Shields, P., and A. Dupuis. 2012. Upper Cook Inlet commercial fisheries annual management
report, 2010. Alaska Department of Fish and Game, Fishery Management Report No. 10-
54, Anchorage.
Yanusz, R. J., R. A. Merizon, T. M. Willette, D. G. Evans, and T. R. Spencer. 2011. Inriver
abundance and distribution of spawning Susitna River sockeye salmon (Oncorhynchus
nerka), 2008. Alaska Fishery Data Series No. 11-12. Department of Fish and Game,
Divisions of Sport and Fish and Commercial Fisheries.
FINAL STUDY PLAN ANALYSIS OF FISH HARVEST IN AND DOWNSTREAM OF THE
SUSITNA-WATANA HYDROELECTRIC PROJECT AREA 9.15
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.15-11 July 2013
9.15.10. Tables
Table 9.15-1. Schedule for implementation of the Analysis of Fish Harvest Study.
Activity 2012 2013 2014 2015
1 Q 2 Q 3 Q 4 Q 1 Q 2 Q 3 Q 4 Q 1 Q 2 Q 3 Q 4 Q 1 Q
Compile harvest & effort statistics --------
Apportion commercial harvests using
genetics
Estimate potential changes to abundance
Estimate potential changes to distribution
Analyze changes to harvest and opportunity
Initial Study Report Δ
Updated Study Report ▲
Legend:
Planned Activity
----- Follow-up activity (as needed)
Δ Initial Study Report
▲ Updated Study Report
FINAL STUDY PLAN ANALYSIS OF FISH HARVEST IN AND DOWNSTREAM OF THE
SUSITNA-WATANA HYDROELECTRIC PROJECT AREA 9.15
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.15-12 July 2013
9.15.11. Figures
Figure 9.15-1. Upper Cook Inlet Management Commercial Fishing Districts and Statistical Reporting Areas (Shields and
Dupuis 2012).
FINAL STUDY PLAN ANALYSIS OF FISH HARVEST IN AND DOWNSTREAM OF THE
SUSITNA-WATANA HYDROELECTRIC PROJECT AREA 9.15
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9.15-13 July 2013
Figure 9.15-2. Northern Cook Inlet Management Area Sport Fishing Management Units (Oslund and Ivey 2010).
FINAL STUDY PLAN ANALYSIS OF FISH HARVEST IN AND DOWNSTREAM OF THE
SUSITNA-WATANA HYDROELECTRIC PROJECT AREA 9.15
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 14 July 2013
Figure 9.15-3. Study Interdependencies for Analysis of Fish Harvest Study.