HomeMy WebLinkAboutRiparian instream flow study section 8.6 2014Alaska Resources Library & Information Services
Susitna-Watana Hydroelectric Project Document
ARLIS Uniform Cover Page
Title:
Riparian instream flow study, Study plan Section 8.6 : Initial study report
SuWa 207
Author(s) – Personal:
Author(s) – Corporate:
R2 Resource Consultants
AEA-identified category, if specified:
Draft initial study report
AEA-identified series, if specified:
Series (ARLIS-assigned report number):
Susitna-Watana Hydroelectric Project document number 207
Existing numbers on document:
Published by:
[Anchorage : Alaska Energy Authority, 2014]
Date published:
February 2014
Published for:
Alaska Energy Authority
Date or date range of report:
Volume and/or Part numbers:
Study plan Section 8.6
Final or Draft status, as indicated:
Draft
Document type:
Pagination:
xii, 124, 7 p.
Related work(s):
Pages added/changed by ARLIS:
Notes:
All reports in the Susitna-Watana Hydroelectric Project Document series include an ARLIS-
produced cover page and an ARLIS-assigned number for uniformity and citability. All reports
are posted online at http://www.arlis.org/resources/susitna-watana/
Susitna-Watana Hydroelectric Project
(FERC No. 14241)
Riparian Instream Flow Study
Study Plan Section 8.6
Initial Study Report
Prepared for
Alaska Energy Authority
Prepared by
R2 Resource Consultants
February 2014 Draft
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page i February 2014 Draft
TABLE OF CONTENTS
Executive summary ........................................................................................................................x
1. Introduction ........................................................................................................................1
2. Study Objectives.................................................................................................................2
3. Study Area ..........................................................................................................................3
4. Methods and Variances in 2013 ........................................................................................3
4.1. Synthesize Historic Physical and Biological Data for Susitna River Floodplain
Vegetation, Including 1980s Studies, Studies of Hydro Project Impacts on
Downstream Floodplain Plant Communities, and Studies of Un-impacted
Floodplain Plant Community Successional Processes (hereafter, Literature
Review of Dam Effects on Downstream Vegetation) 4
4.1.1. Methods........................................................................................... 4
4.1.2. Variances from Study Plan ............................................................. 5
4.2. Focus Area Selection−Riparian Process Domain Delineation 5
4.2.1. Methods........................................................................................... 6
4.2.2. Variances from Study Plan ............................................................. 8
4.3. Characterize Seed Dispersal and Seedling Establishment Groundwater and
Surface Water Hydroregime Requirements. Develop Predictive Model of
Potential Project Operational Impacts to Seedling Establishment (hereafter,
Seed Dispersal and Seedling Establishment) 8
4.3.1. Synchrony of Seed Dispersal, Hydrology, and Local Susitna River
Valley Climate ................................................................................ 8
4.3.2. Seedling Establishment and Recruitment ..................................... 10
4.4. Characterize the role of river ice in the establishment and recruitment of dominant
floodplain vegetation. Develop predictive model of potential Project
operational impacts to ice processes and dominant floodplain vegetation
establishment and recruitment (hereafter, River Ice Effects on Floodplain
Vegetation) 15
4.4.1. Empirical Studies of River Ice and Floodplain Vegetation .......... 15
4.4.2. Ice Process Modeling .................................................................... 16
4.4.3. Methods......................................................................................... 16
4.4.4. Variances from Study Plan ........................................................... 18
4.5. Characterize the role of erosion and sediment deposition in the formation of
floodplain surfaces, soils, and vegetation. Develop a predictive model of
Project operations changes to erosion and sediment deposition patterns and
associated floodplain vegetation (hereafter, Floodplain Stratigraphy and
Floodplain Development) 18
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page ii February 2014 Draft
4.5.1. Methods......................................................................................... 19
4.5.2. Variances from Study Plan ........................................................... 20
4.6. Characterize natural floodplain vegetation groundwater and surface water
maintenance hydroregime. Develop a predictive model to assess potential
Project operational changes to natural hydroregime and floodplain vegetation
(hereafter, Riparian GW/SW Hydroregime) 21
4.6.1. Riparian GW/SW Hydroregime Overview ................................... 21
4.6.2. Methods......................................................................................... 22
4.6.3. Riparian Plant-Frequency Response Curves ................................. 26
4.6.4. Variances from Study Plan ........................................................... 26
4.7. Floodplain Vegetation Study Synthesis, Focus Area to Riparian Process Domain
Model Scaling and Project Operations Effects Modeling (hereafter, Riparian
Vegetation Modeling Synthesis and Project Area Scaling) 27
4.7.1. Methods......................................................................................... 27
4.7.2. Variances from Study Plan ........................................................... 28
5. Results ...............................................................................................................................28
5.1. Literature Review of Dam Effects on Downstream Vegetation 28
5.2. Focus Area Selection−Riparian Process Domain Delineation 28
5.3. Seed Dispersal and Seedling Establishment 30
5.3.1. Seed Dispersal ............................................................................... 30
5.3.2. Seedling Establishment and Recruitment ..................................... 31
5.4. River Ice Effects on Floodplain Vegetation 34
5.5. Floodplain Stratigraphy and Floodplain Development 35
5.6. Riparian GW/SW Hydroregime 35
5.6.1. Stable Isotope Analyses ................................................................ 35
5.6.2. Rooting Depth ............................................................................... 36
5.6.3. Plant Transpiration ........................................................................ 36
5.7. Floodplain Vegetation Modeling Synthesis and Project Scaling 38
6. Discussion..........................................................................................................................38
6.1. Literature Review of Dam Effects on Downstream Vegetation 38
6.2. Focus Area Selection−Riparian Process Domain Delineation 38
6.3. Seed Dispersal and Seedling Establishment 38
6.4. River Ice Effects on Floodplain Vegetation 39
6.5. Floodplain Stratigraphy and Floodplain Development 39
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page iii February 2014 Draft
6.6. Riparian GW/SW Hydroregime 40
6.7. Floodplain Vegetation Modeling Synthesis and Project Scaling 40
7. Completing the Study ......................................................................................................41
8. Literature Cited ...............................................................................................................41
9. Tables ................................................................................................................................47
10. Figures ...............................................................................................................................70
LIST OF TABLES
Table 4.1-1. Floodplain Vegetation and Physical Process Regimes Critical Review,
Synthesis and Lessons Learned..............................................................................................47
Table 4.2-1. Focus Area Selection−Riparian Process Domain Delineation. ................................48
Table 4.3-1. Synchrony of Seed Dispersal, Hydrology, and Local Susitna River Valley
Climate. ..................................................................................................................................49
Table 4.3-2. Seedling Establishment and Recruitment Study. ......................................................50
Table 4.4-1. Characterize the role of river ice in the establishment and recruitment of
dominant floodplain vegetation. ............................................................................................51
Table 4.5-1. Characterize the role of erosion and sediment deposition in the formation of
floodplain surfaces, soils, and vegetation. .............................................................................52
Table 4.6-1. Characterize natural floodplain vegetation groundwater and surface water
maintenance hydroregime. .....................................................................................................53
Table 4.7-1. Floodplain Vegetation Study Synthesis, Focus Area to Riparian Process
Domain Model Scaling and Project Operations Effects Modeling. .......................................54
Table 5.2-1. Riparian process domain #1 (RPD1). .......................................................................55
Table 5.2-2. Riparian process domain #3 (RPD3) plant communities typed, and
measured, along transects using Alaska Vegetation Classification (AVC) Level III
(1992) community descriptions. ............................................................................................56
Table 5.2-3. Riparian process domain #4 (RPD4) plant communities typed, and
measured, along transects using Alaska Vegetation Classification (AVC) Level III
(1992) community descriptions. ............................................................................................57
Table 5.2-4. Rationale for Riparian IFS Focus Area selection .....................................................58
Table 5.2-5. List of Focus Areas selected for Riparian-IFS studies within each Riparian
Process Domain. ....................................................................................................................58
Table 5.3-1. Number and species of Salix and Populus surveyed at each of four seed
release study sites located in the Lower and Middle Segments on the Susitna River. ..........59
Table 5.3-2. Day of year when plants have released 20 percent (DY20) and 80 percent
(DY80) of seeds based on 2013 data. ....................................................................................59
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page iv February 2014 Draft
Table 5.3-3. Distribution of seedling establishment transects by Focus Area and
geomorphic position. ..............................................................................................................60
Table 5.3-4. Overview of spruce recruitment transect observations. ...........................................61
Table 5.3-5. Trees sampled on spruce transect islands. ................................................................62
Table 5.5-1. Stem number and mean DBH for trees and selected shrubs at ITU sample
plots. .......................................................................................................................................63
Table 5.6-1. Number of plant isotope samples collected by sample site and plant
community structural type. ....................................................................................................67
Table 5.6-2. Number of soil isotope samples by canopy cover type. ...........................................67
Table 5.6-3. Number of water isotope samples by site, month, and water source. ......................67
Table 5.6-4. Number and species of trees and shrubs with sap flow instrumentation at
each riparian GW/SW station. ...............................................................................................68
Table 5.6-5. List of species sampled for stomatal conductance at each Focus Area. ...................69
Table 5.6-6. Number of stomatal conductance measurements by sampling location,
sample period, and plant community structural type. ............................................................69
LIST OF FIGURES
Figure 4.3-1. Cottonwood (Populus) life history stages: seed dispersal and germination,
sapling to tree establishment. Cottonwood typically germinates on newly created
bare mineral soils associate with lateral active channel margins and gravel bars.
Note proximity of summer baseflow and floodplain water table (Braatne et al. 1996). ........70
Figure 4.3-2. The riparian “Recruitment Box Model” describing seasonal flow pattern,
associated river stage (elevation), and flow ramping necessary for successful
cottonwood and willow seedling establishment (from Amlin and Rood 2002; Rood
et al. 2005). ............................................................................................................................71
Figure 4.3-3. Susitna Project area meteorological station locations. ............................................72
Figure 4.4-1. Balsam poplar tree ice-scar. Floodplain located immediately above Three
Rivers Confluence. .................................................................................................................73
Figure 4.4-2. Balsam poplar forest tree ice-scars. Floodplain located immediately above
Three Rivers Confluence. ......................................................................................................74
Figure 4.4-3. Floodplain ice deposited gravel piles. Floodplain in braided reach below
Three Rivers Confluence. ......................................................................................................75
Figure 4.6-1. Riverine hydrologic landscape (Winter 2001). .......................................................77
Figure 4.6-2. (A) Transect profile view of typical monitoring well and stage recorder
locations looking down river. (B) Gold Creek Gauge Station, Susitna River April
through September 2005-2009. ..............................................................................................78
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page v February 2014 Draft
Figure 5.2-1. Riparian Process Domains on the Middle River with locations of associated
Riparian IFS Focus Areas. .....................................................................................................79
Figure 5.3-1. Location of four seed release sites surveyed in 2013 on the Susitna River. ...........80
Figure 5.3-2. Seed Dispersal Study Site at PRM 47: Deshka Landing.........................................81
Figure 5.3-3. Seed Dispersal Study Site at PRM 88: Parks Highway Bridge. .............................82
Figure 5.3-4. Seed Dispersal Study Site at PRM 102: Talkeetna .................................................83
Figure 5.3-5. Seed Dispersal Study Site at PRM 142: Indian River ............................................84
Figure 5.3-6. Daily air temperatures used for modeling at four sites. ..........................................85
Figure 5.3-7. Peak seed release period in 2013 for Populus balsamifera at PRM 47
(Deshka Landing) and PRM 88 (Parks Highway Bridge) with discharge from the
USGS Sunshine gauge (PRM 88). .........................................................................................86
Figure 5.3-8. Peak seed release period in 2013 for Populus balsamifera at PRM 102
(Talkeetna) and PRM 142 (Indian River) with discharge from the USGS Gold Creek
gauge. .....................................................................................................................................86
Figure 5.3-9. Seedling Establishment Study Transect Locations at FA104. ................................87
Figure 5.3-10. Seedling Establishment Study Transect Locations at FA113. ..............................88
Figure 5.3-11. Seedling Establishment Study Transect Locations at FA128. ..............................89
Figure 5.3-12. Seedling Establishment Study Transect Locations at FA138. ..............................90
Figure 5.3-13. Seedling Establishment Study Transect Locations at FA144. ..............................91
Figure 5.3-14. Year 1 poplar seedling survival by transect between August and
September sampling periods. .................................................................................................92
Figure 5.3-15. Year 1 willow seedling survival by transect between August and
September sampling periods. .................................................................................................92
Figure 5.3-16. Year 1 poplar seedling survival plotted by geomorphic position. ........................93
Figure 5.3-17. Year 1 willow seedling survival plotted by geomorphic position.........................93
Figure 5.3-18. Discharge at Gold Creek and rainfall observed at FA-104 and FA-128
during the 2013 seedling establishment sampling period. .....................................................94
Figure 5.3-19. Stem length versus root length of first year poplar seedlings along
Transect FA-104 STR1. .........................................................................................................94
Figure 5.3-20. Seedling survival between August and September sampling efforts and
elevation of surface and cobble/gravel armoring (c) at FA113 STR5. ..................................95
Figure 5.3-21. Seedling survival between August and September sampling efforts and
elevation of surface and cobble/gravel armoring (c) at a representative transect
FA128 STR4. .........................................................................................................................96
Figure 5.3-22. Seedling survival between August and September sampling efforts and
elevation of surface and cobble/gravel armoring (c) at a representative transect
FA144 STR4. .........................................................................................................................97
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page vi February 2014 Draft
Figure 5.3-23. White spruce establishment transect locations and dendrology plots in
FA-104. ..................................................................................................................................98
Figure 5.3-24. White spruce establishment transect locations and dendrology plots in
FA-113. ..................................................................................................................................99
Figure 5.3-25. White spruce establishment transect locations and dendrology plots in
FA-115. ................................................................................................................................100
Figure 5.3-26. White spruce establishment transect locations and dendrology plots near
in FA-128. ............................................................................................................................101
Figure 5.3-27. White spruce establishment transect locations and dendrology plots near
PRM 112 and 135. ...............................................................................................................102
Figure 5.3-28. Total number of seedling spruce trees per hectare along each island
transect. ................................................................................................................................103
Figure 5.3-29. Total number of spruce trees per hectare along each island transect. .................103
Figure 5.3-30. Total number of snag spruce trees per hectare along each island transect. .........104
Figure 5.3-31. Spruce density and basal area by 30 meter quadrat increments observed
along an eight-meter-wide belt transect (Transect 1) on mid-channel island at PRM
115.6. ....................................................................................................................................104
Figure 5.3-32. Spruce density and basal area by 30 meter quadrat increments observed
along an eight-meter-wide belt transect (Transect 1) on mid-channel island at PRM
128.1. ....................................................................................................................................105
Figure 5.3-33. Example of soil core on island PRM 128.1 showing layers with high
organic matter content overlain by mineral soil. .................................................................106
Figure 5.3-34. Mean number of organic layers in upper 30 cm of soil profile and depth to
cobble at randomly selected locations across each island in the spruce seedling
establishment study. .............................................................................................................107
Figure 5.4-1. Top of ice scar above floodplain height (in feet) for scar observations
between PRM 102.2 and 145.8. ...........................................................................................108
Figure 5.4-2. Box and whisker plots of top of ice scar heights (ft) above the floodplain
surface at three focus areas. Black squares represent mean height. ....................................109
Figure 5.4-3. Map of ice scar locations at a representative reach with frequent ice scars
from PRM 132.1 to 135.0. ...................................................................................................110
Figure 5.4-4. Map of ice scar locations at a representative reach with infrequent ice scars
from PRM 116.9 to 121.3. ...................................................................................................111
Figure 5.4-5. Map of ice scar locations and sampled ice scar wedges at FA-104. .....................112
Figure 5.5-1. Sediment core sampling locations and Dendrology Plots surveyed at
FA-104. ................................................................................................................................113
Figure 5.5-2. Sediment core sampling locations and Dendrology Plots surveyed at
FA-115. ................................................................................................................................114
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page vii February 2014 Draft
Figure 5.6-1. Riparian GW/SW sampling locations at FA-104. .................................................115
Figure 5.6-2. Riparian GW/SW sampling locations at FA-115. .................................................116
Figure 5.6-3. Riparian GW/SW sampling locations at FA-128. .................................................117
Figure 5.6-4. Distribution of Plant Isotope Samples by Plant Species at FA-104 and
FA-128. ................................................................................................................................118
Figure 5.6-5. Sample data for sap velocity at two representative floodplain sampling
locations at FA-104 between August 11, 2013 and August 27, 2013 (Julian day 223-
237) for (A) P. glauca and (B) B. papyrifera and (C) vapor pressure deficit during
this sample period. ...............................................................................................................119
Figure 5.6-6. Sap velocity for representative P. glauca and B. papyrifera trees at Station
ESAFA104-4. .......................................................................................................................120
Figure 5.6-7. Seasonal Stomatal Conductance Distribution by Selected Species for (a) C.
canadensis and (b) H. lanatum. ............................................................................................121
Figure 5.6-8. Seasonal Stomatal Conductance Distribution by Selected Species for
(a) M. struthiopteris, and (b) V. edule..................................................................................122
Figure 5.6-9. Seasonal Leaf Area Index (LAI) by Canopy Types for (a) Alder/Willow,
(b) Poplar, and (c) Spruce/Birch. .........................................................................................123
Figure 5.6-10. Soil Volumetric Water Content (θ) measured at FA-104 at depths ranging
from 5 to 200 cm. .................................................................................................................124
Figure 1. Middle River Riparian Process Domains and Focus Areas. ............................................4
Figure 2. Length of transects typed as herbaceous vegetation within Riparian Process
Domains 1-4 compared with herbaceous vegetation typed along transects within the
Focus Areas associated with each RPD. Lengths are in meters..............................................5
Figure 3. Area (ac) of Herbaceous AVC Level II Cover Types in each of three Focus
Areas relative to portion of RPD3 with completed Integrated Terrain Unit Mapping. ...........6
Figure 4. Sum of transect lengths (in meters) by cover type for Herbaceous AVC Level
II for the part of RPD3 and Focus Areas without completed Integrated Terrain Unit
Mapping. ..................................................................................................................................7
APPENDICES
Appendix A: Riparian Focus Area Selection: Response to Agency Comments Regarding
Herbaceous Vegetation
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page viii February 2014 Draft
LIST OF ACRONYMS, ABBREVIATIONS, AND DEFINITIONS
Abbreviation Definition
AEA Alaska Energy Authority
DBH Diameter at Breast Height; approximately 1.4 meters from ground
DD Degree Day
DY20 Day of Year when plants have released 20 percent of seeds
DY80 Day of Year when plants have released 80 percent of seeds
FERC Federal Energy Regulatory Commission
GIS Geographic Information System
GW/SW Groundwater/Surface Water
HEC-RAS Hydrologic Engineering Centers River Analysis System
HEC-GEORAS A GIS extension that prepares GIS data for import into HEC-RAS and generation of
GIS data from HEC-RAS output
ILP Integrated Licensing Process
ITU Integrated Terrain Unit
ISR Initial Study Report
LAI Leaf Area Index
PRM Project River Mile; determined during 2012-2013 studies
Project Susitna-Watana Hydroelectric Project
QC Quality Control
Riparian IFS Riparian Instream Flow Study
RIMS Resonant Ionization Mass Spectrometer
RIP-ET Riparian – Evapotranspiration, a package used with MODFLOW groundwater
modeling program.
RM River Mile; determined from 1980s study
RMSE Relative mean-squared error
RPD Riparian Process Domain
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page ix February 2014 Draft
Abbreviation Definition
RSP Revised Study Plan
SPD Study Plan Determination
TDP Thermal Dissipation Probe
USFWS U.S. Fish and Wildlife Service
VPD Vapor Pressure Deficit
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page x February 2014 Draft
EXECUTIVE SUMMARY
Riparian Instream Flow Study 8.6
Purpose The purpose of this study is to provide a quantitative, spatially explicit model to
predict potential impacts to downstream floodplain vegetation from Project
operational flow modification of natural Susitna River flow, sediment, and ice
process regimes.
Status This is a multi-year study initiated in 2013. The first year of field data has been
collected for all components of this study. The study team is analyzing data and
preparing to continue data collection efforts to complete the study.
Study Components Study components include the following activities:
1. Literature Review of Dam Effects on Downstream Vegetation
2. Focus Area Selection−Riparian Process Domain Delineation
3. Seed Dispersal and Seedling Establishment
4. River Ice Effects on Floodplain Vegetation
5. Floodplain Stratigraphy and Floodplain Development
6. Riparian GW/SW Hydroregime
7. Floodplain Vegetation Modeling Synthesis and Project Scaling
2013 Variances AEA implemented the methods as described in the Study Plan with the exception of
the variances listed below.
• Completion of the literature review was scheduled for Q4 2013 and is now
scheduled for 2014 (see Section 4.1).
• The first year (0+) balsam poplar and willow establishment study was restricted
to documenting the current cohort of seedlings less than 1 year old rather than
all woody plants less than 1 meter in height. In response to this variance, AEA
anticipates conducting a clonal reproduction study to characterize asexual
recruitment patterns (see Section 4.3.2).
Steps to Complete
the Study
As explained in the cover letter to this draft ISR, AEA’s plan for completing this
study will be included in the final ISR filed with FERC on June 3, 2014.
Highlighted
Results and
Achievements
The Riparian IFS Study successfully accomplished all of the 2013 field objectives
as described in the Study Plan. Accomplishments and key finding for each element
of the study include the following:
Literature Review of Dam Effects on Downstream Vegetation
• More than 110 peer-reviewed articles were reviewed. An annotated
bibliography and summary of findings will be presented in a literature review
combined with the Fluvial Geomorphology literature review.
Focus Area Selection−Riparian Process Domain Delineation
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page xi February 2014 Draft
Riparian Instream Flow Study 8.6
• Riparian Process Domains (RPD) were identified for the entire Middle River
Segment, and the TWG technical team was consulted to assist in selecting
Focus Areas for riparian studies that are representative of each RPD.
Seed Dispersal and Seedling Establishment
• Catkins releasing seed from 6 female balsam poplar (Populus balsamifera) trees
and 6 to 12 female willow (Salix spp.) shrubs were counted weekly at each of
four seed release study sites distributed across the Middle and Lower River
Segments.
• First year (0+) balsam poplar and willow seedling establishments were
documented with 35 transects and 824 plots across five Focus Areas. Counts of
established seedlings were completed in late July through early August and
again in September 2013. To characterize white spruce establishment patterns,
12 8-meter-wide (26.25 feet wide) belt transects were surveyed covering
approximately 3.5 hectares (8.7 acres) on seven mid-channel islands in the
Middle River Segment.
• Significant mortality was observed as a result of the mid-August peak flow.
Seedling survival occurred in sheltered terrain positions whereas high seedling
mortality was observed resulting from both channel bed scour and sediment
burial in exposed lateral channel margins.
• Seedling establishment study identified previously unreported white spruce
establishment in tall alder seral stage. White spruce was shown to establish
throughout early floodplain forest successional stages.
• Only balsam poplar and willow year 0+ seedlings were observed in woody
seedling reconnaissance surveys.
• Clonal reproduction of balsam poplar appears to be a significant recruitment
process in high ice flow disturbance zones. What appeared to be poplar sexual
reproduction in these terrain areas is not. This finding has potential significance
relative to assessment of Project operations effects on ice regime interactions
with riparian vegetation, an assessment objective of the vegetation ice processes
study.
River Ice Effects on Floodplain Vegetation
• The Riparian IFS team was able to aerially observe a significant 2013 river ice
breakup over 2 days, providing observations of ice dam backwater flooding,
floodplain sediment deposition, and extensive ice flow damage to floodplain
vegetation. Identifying floodplain areas to study floodplain vegetation response
to ice flow and sediment disturbances was an objective of 2013 fieldwork.
• A systematic riverbank survey of tree ice scars was conducted from PRM 102.2
through PRM 145.8 between September 15 and 29, 2013. A total of 222 ice-
scarred trees, 190 locations with no visible ice-scars, and 29 locations with signs
of ice damage that were not measurable were surveyed. In addition, 48 ice-
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page xii February 2014 Draft
Riparian Instream Flow Study 8.6
scarred trees were sampled for dendrochronologic analysis of ice floodplain
vegetation interaction frequency and magnitude.
• Ice dam backwater flooding was observed to deposit up to 20 to 30 cm of fine
sand burying existing floodplain vegetation. Sediment deposition during ice
dam backwater was observed to be a local phenomenon associated with ice dam
backwater floods. Ice process generated floodplain sediment deposition is
potentially a significant driver of local floodplain vegetation pattern.
Floodplain Stratigraphy and Floodplain Development
• Sediment cores were collected during 2013 at 13 locations in the Middle River
Segment, including 5 cores at FA-104 (Whiskers Slough) and 8 cores at FA-115
(Slough 6A).
• Tree and shrub composition and abundance were measured at 80 ITU and mid-
channel island plots in the Middle and Lower River Segments. Tree core
samples for dendrochronologic analysis were collected at all ITU plots.
• Analysis of sediment cores and aging of tree cores is in progress.
Riparian GW/SW Hydroregime
• Riparian Groundwater/Surface Water studies included collection of 659 plant
samples, 545 soil samples, and 100 water samples for isotopic analysis of water
source. Transpiration of woody species was measured with TDP sensors
installed at 21 trees at FA-104 (Whiskers Slough) and 27 trees at FA-128
(Slough 8A). Transpiration by herbaceous and small shrub species was
measured through collection of 3,602 individual stomatal conductance
measurements, including measurements from 1,747 herbaceous plants (11
species), 1,771 shrubs (11 species), and 79 trees (3 species).
• FA-138 (Gold Creek) river right floodplain wetlands were shown to not be
strongly influenced by surface water fluctuations associated with the mid-
August peak flow. This observation was made by measuring floodplain off-
channel water body surface water elevations as compared to river stage
fluctuations.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 1 February 2014 Draft
1. INTRODUCTION
On December 14, 2012, Alaska Energy Authority (AEA) filed with the Federal Energy
Regulatory Commission (FERC or Commission) its Revised Study Plan (RSP), which included
58 individual study plans (AEA 2012). Included within the RSP was the Riparian Instream Flow
Study (Section 8.6). This section focuses on the methods for assessing the effects of the
proposed Project and its operations on the floodplain plant communities in the Susitna River
basin.
On April 1, 2013, FERC issued its study determination (April 1 SPD) for RSP Section 8.6,
approving the study with modifications. In its April 1 SPD, FERC recommended the following:
Seedling Establishment
• We recommend that the study plan be modified to require AEA to sample seedling
establishment following the initial spring peak flows (e.g., July) and again in
September in 2013 and 2014.
Adequacy of MODFLOW and Xylem Water Isotopic Sampling to Establish
Groundwater/Hydroperiod Relationships
• We recommend that AEA consult with the TWG on the sampling design for
collecting plant xylem water; and file no later than June 30, 2013, the following:
1) A detailed description of the sampling sites, frequency, and schedule.
2) Documentation of consultation with the TWG, including how its comments were
addressed.
Soil Profile Sampling
• We recommend that the study plan be modified to specify that sediment grain size
measurements would be based on samples taken at soil horizons, rather than at
equal depth increments.
Vegetation Response Curves
• We recommend that AEA do so in consultation with the riparian technical
workgroup. Methods of analysis should be reported in the initial and updated study
reports.
Consultation on the interrelated Riparian Vegetation Study Downstream of the Proposed Susitna-
Watana Dam (Riparian Vegetation Study 11.6), Riparian Instream Flow Study (Riparian IFS
Study 8.5), and Groundwater Study (Study 7.5) study plans was accomplished with TWG
representatives in two meetings, held on April 23, 2013 and June 6, 2013. Licensing participants
were provided the opportunity to address technical details and comments and concerns regarding
the study’s approaches and methods.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 2 February 2014 Draft
The Riparian Instream Flow, Groundwater, and Riparian Vegetation Studies FERC
Determination Response Technical Memorandum (Riparian/GW TM) addresses FERC’s April 1
SPD request concerning sampling design for collecting plant xylem water (R2 Resource
Consultants et al. 2013). The Riparian/GW TM was filed with FERC on July 1, 2013.
Following the first study season, FERC’s regulations for the Integrated Licensing Process (ILP)
require AEA to “prepare and file with the Commission an initial study report describing its
overall progress in implementing the study plan and schedule and the data collected, including an
explanation of any variance from the study plan and schedule” (18 CFR 5.15(c)(1)). This Initial
Study Report (ISR) on the Riparian Instream Flow Study has been prepared in accordance with
FERC’s ILP regulations and details AEA’s status in implementing the study, as set forth in the
FERC-approved RSP and as modified by FERC’s April 1 SPD and Riparian/GW TM
(collectively referred to herein as the “Study Plan”).
2. STUDY OBJECTIVES
The goal of the Riparian Instream Flow Study (hereafter Riparian IFS) is to provide a
quantitative, spatially explicit model to predict potential impacts to downstream floodplain
vegetation from Project operational flow modification of natural Susitna River flow, sediment,
and ice regimes. To meet this goal, AEA is applying a physical and vegetation process modeling
approach. First, existing Susitna River groundwater and surface water (GW/SW) flow, sediment,
and ice regimes are being measured and modeled relative to floodplain plant community
establishment, recruitment, and maintenance requirements. Second, predictive models are being
developed to assess potential Project operational impacts to floodplain plant communities and
provide operational guidance to minimize these impacts. Third, the predictive models are being
applied spatially in a Geographic Information System (GIS) to the riparian vegetation map
produced by the Riparian Vegetation Study (Study 11.6) to produce a series of maps of predicted
changes under alternative operational flow scenarios.
Seven Riparian IFS objectives were established in RSP Section 8.6.1:
1. Synthesize historic physical and biological data for Susitna River floodplain vegetation,
including 1980s studies, studies of hydro project impacts on downstream floodplain plant
communities, and studies of un-impacted floodplain plant community successional
processes.
2. Delineate sections of the Susitna River with similar environments, vegetation, and
riparian processes, termed riparian process domains (RPDs), and select representative
areas within each riparian process domain, termed Focus Areas, for use in detailed 2013–
2014 field studies.
3. Characterize seed dispersal and seedling establishment groundwater and surface water
hydroregime requirements. Develop a predictive model of potential Project operational
impacts to seed dispersal and seedling establishment.
4. Characterize the role of river ice in the establishment and recruitment of dominant
floodplain vegetation. Develop a predictive model of potential Project operational
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 3 February 2014 Draft
impacts to ice process regimes and dominant floodplain vegetation establishment and
recruitment.
5. Characterize the role of erosion and sediment deposition in the formation of floodplain
surfaces, soils, and vegetation. Develop a predictive model of Project operations changes
to erosion and sediment deposition patterns and associated floodplain vegetation.
6. Characterize natural floodplain vegetation groundwater and surface water maintenance
hydroregime. Develop a predictive model to assess potential changes to natural
hydroregime and potential floodplain vegetation.
7. Develop floodplain vegetation study synthesis, scaling of Focus Areas to riparian process
domains, and Project operations effects modeling.
3. STUDY AREA
As established in RSP Section 8.6.2, the study area includes the Susitna River active floodplain
that would be affected by the operation of the Project downstream of the proposed Watana Dam
(PRM 187.1). The active floodplain is the valley bottom flooded under the current climate. For
the 2013 work, the lateral extent of the riparian vegetation study area was defined by the extent
of the riverine physiographic region generated by the Susitna River. Riverine physiography
includes (1) those areas of the valley bottom, including off-channel water bodies, that are directly
influenced by regular (0–25 year) to irregular (25–100 year) overbank flooding; and (2) those
areas of the valley bottom influenced indirectly by groundwater associated with the Susitna
River. The riverine physiographic map has undergone review and refinement by the principal
investigators leading the Riparian IFS, Riparian Vegetation Study (Study 11.6), and associated
physical processes studies (Groundwater, Ice Processes, and Fluvial Geomorphology Modeling).
Upon review of 2013 field data, the active floodplain map will be revised, as needed, and a final
riverine physiography layer will be prepared for use as the lateral boundary of the Riparian IFS
Study for subsequent study.
The longitudinal extent of the 2013 study area for the Riparian IFS Study has been defined in
coordination with the Riparian Vegetation, Fluvial Geomorphology Modeling, and Groundwater
Studies. The study area includes those riparian areas downstream of the Project dam site to a
point at which the effects of altered stage and flow effects expected in the Susitna River would
not be ecologically significant (i.e., the expected hydraulic alterations would be overridden by
the input from other rivers and/or the effects of tidal fluctuations from Cook Inlet). Following
the completion of the Open-water Flow Routing Model in Q1 2013, AEA, after receiving input
from the TWG, extended the downstream extent of the study areas for the riparian studies,
including the Riparian Vegetation Study, to PRM 29.9 (R2 2013b).
4. METHODS AND VARIANCES IN 2013
The Riparian IFS will develop a process-based model of riparian vegetation succession and
dynamics driven by riverine hydrogeomorphic processes. The modeling approach uses
geomorphic, hydraulic, ice process, and GW/SW interaction models coupled with riparian
vegetation succession models based upon riparian vegetation surveys and previous Susitna River
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 4 February 2014 Draft
riparian forest research (Helm and Collins 1997). Objectives of the modeling approach are as
follows:
1. Measure and model riparian vegetation physical process relationships under the natural
flow, sediment, and ice regimes.
2. Model potential impacts to riparian vegetation resulting from Project operational changes
to natural flow, sediment, and ice process regimes.
3. Provide guidance for Project operation scenarios to minimize potential riparian
vegetation impacts.
The Riparian IFS methods section is presented in the following format addressing each of the
seven Project components and objectives as they have been completed in 2013. First, each study
component and its associated objectives are described. Second, study methods, with appropriate
literature citations, are presented. Third, any variances from the Study Plan are presented. The
Riparian IFS Project schedule and plans for completing the study are presented in Section 7.
4.1. Synthesize Historic Physical and Biological Data for Susitna
River Floodplain Vegetation, Including 1980s Studies, Studies
of Hydro Project Impacts on Downstream Floodplain Plant
Communities, and Studies of Un-impacted Floodplain Plant
Community Successional Processes (hereafter, Literature
Review of Dam Effects on Downstream Vegetation)
The goal of this study is to critically review and synthesize historic Susitna River riparian
vegetation studies within the context of physical process investigations conducted in the 1980s,
including ice processes, sediment transport, GW/SW, and herbivory. Studies of downriver
floodplain vegetation response to hydroregulation on other hydro projects (both North American
and circumpolar) are being incorporated into the review to develop a current state-of-the-science
analysis of potential Project operational flow effects to Susitna River riparian floodplain
vegetation. Additionally, studies of un-impacted temperate and boreal floodplain plant
community successional processes will be incorporated into the study as appropriate. Study
objectives, methods, and expected results are summarized in Table 4.1-1.
The objectives of this study task are as follows:
1. Conduct a critical review of previous Susitna River 1980s floodplain vegetation studies.
2. Place potential Project operational effects within the context of studies from other
hydroregulated rivers in North America.
3. Review, and include relevant findings of, current research concerning temperate and
boreal floodplain forest succession and dynamics under natural flow regimes.
4.1.1. Methods
AEA implemented the methods as described in the Study Plan with the exception of variances
explained below (Section 4.2.1).
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 5 February 2014 Draft
A critical literature review of all appropriate Susitna River 1980s studies, historic and current
hydro project floodplain effects studies, and temperate and boreal floodplain forest scientific
literature is being developed in coordination with the Fluvial Geomorphology Modeling
literature review. The synthesis of findings will focus on elements relevant to evaluating
potential Project operation effects on downstream floodplain vegetation. An annotated,
searchable bibliography will be developed in coordination with the critical literature review.
4.1.2. Variances from Study Plan
Completion of the literature review was scheduled for Q4 2013 and is now scheduled for 2014.
Because of the close linkage between the riparian and geomorphology studies, the review will
now be a combined literature review for both studies. However, this variance will actually
benefit the Project in that the literature review will be more comprehensive and combine
information for both riparian and fluvial geomorphology into one document.
4.2. Focus Area Selection−Riparian Process Domain Delineation
Floodplain plant communities within northern mountain river corridors are dynamic as channel
and ice processes annually disturb floodplain vegetation. The characteristic patchwork of
floodplain vegetation composition, structure, and age reflects patterns of disturbance across the
floodplain landscape (Naiman et al. 1998). Vegetation disturbance can be defined as those
processes that remove or otherwise impact plant communities and soils, often setting the system
back to an earlier successional state. Floodplain vegetation disturbance types found within the
study area include channel migration (erosion and depositional processes), ice processes
(shearing impacts, flooding, freezing, and sediment deposition), herbivory (beaver, moose, and
hare), wind, and, to an infrequent extent, fire. Floodplain disturbance regimes (type, magnitude,
frequency, duration, and timing) vary systematically throughout river networks and, therefore,
their geographic distribution may be mapped (Montgomery 1999).
Process domains define specific geographic areas in which various geomorphic processes govern
habitat attributes and dynamics (Montgomery 1999). Within the mountain river network,
temporal and spatial variability of channel, ice, and sediment disturbance processes can be
classified and mapped, allowing characterization of specific riparian process domains with
similar suites of floodplain disturbance types. The riparian process domain approach is
hierarchical in structure, allowing for river network stratified sampling to statistically describe
elements and processes within each process domain. Riparian IFS Study sites, including those
located within Focus Areas, were selected to capture the variability in floodplain vegetation, and
geomorphic terrains, within each riparian process domain. The number of riparian Focus Areas
necessary to capture process domain variability was determined through a spatially constrained
cluster analysis. The hierarchical stratification of the Susitna River basin into riparian process
domains facilitates both representative sampling and the ”scaling-up” of Focus Area modeling
results to the larger study area.
The issue of pseudoreplication (Hurlbert 1984), and the number of adequate sample sites
necessary to perform robust statistical analyses, is addressed in the hierarchical riparian process
domain sampling design and integration of the Riparian Vegetation Study design. Focus Area
sites have been selected to be representative of specific riparian process domains and their
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 6 February 2014 Draft
channel/floodplain characteristics (ice process domains, channel planform, channel slope,
channel confinement). Focus Area physical and vegetation processes will be modeled and
floodplain vegetation-flow response relationships statistically described in probabilistic models
(Rains et al. 2004). The Riparian Vegetation Study (see ISR Study 11.6 for vegetation statistical
sampling protocols) is designed to provide study area-wide representative sample replicates of
floodplain vegetation, soils, and alluvial terrain relationships. Furthermore, the surface water
flood regime for the study area will be modeled, and mapped, providing flow regime plant
community relationship anal ysis replicates throughout the greater study area, in addition to those
modeled at each Focus Area. The riparian process domain and study area-wide sampling of the
Riparian Vegetation Study are specifically designed to address the question of pseudoreplication.
Study objectives, methods, and expected results are summarized in Table 4.2-1.
The objectives of the Focus Area selection and riparian process domain delineation are as
follows:
1. Develop a riparian process domain stratification of the study area.
2. Select Focus Areas representative of each riparian process domain for physical process
and vegetation survey sampling and modeling.
4.2.1. Methods
AEA implemented the methods as described in the Study Plan with no variances.
Preliminary riparian process domain delineation and riparian Focus Area selection was an
iterative process. This iterative process is described in the steps below. First, in 2012, the
Middle River Segment (PRM 102.4-187.1) was delineated into large-scale geomorphic river
segments with relatively homogeneous characteristics, including channel width, entrenchment,
ratio, sinuosity, slope, geology/bed material, single/multiple channel, braiding index, and
hydrology (inflow from major tributaries). Ten candidate Focus Areas were defined as important
for the Fish and Aquatics IFS (FA-IFS) Study (see ISR Study 8.5). From these ten initial
candidate Focus Areas, a total of five Focus Areas for further riparian study were ultimately
selected.
Second, prior to selection of any riparian Focus Areas in 2012, the Riparian-IFS lead
independently examined the entire Middle River Segment from the proposed Watana Dam site to
the Three Rivers Confluence and selected eight sections 1 to 3 miles in length that captured,
upon first examination, variability in channel confinement (active channel/floodplain width) and
channel planform. These eight candidate sections were ultimately found to correspond to eight
of the ten Focus Areas selected in the FA-IFS Study 8.5 and in the R2 Resource Consultants
Technical Memorandum (2013). The overlap in the independently selected riparian floodplain
and FA-IFS Focus Areas is not surprising because they represent the most geomorphically
complex reaches in the Middle River Segment in terms of channel and floodplain complexity.
Third, questions remained, however, whether the eight Focus Areas identified for riparian
analysis were representative of vegetation types and abundance within the entire Middle River
Segment, and whether all eight Focus Areas were necessary to fully capture variability in plant
community characteristics across the study area. To statistically evaluate the representativeness
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 7 February 2014 Draft
of the riparian Focus Area selections, a detailed quantitative analysis was completed that
involved the determination of riparian process domains and vegetation typing within the entire
Middle River Segment. This analysis allowed for comparisons of vegetation types and
abundance both between Focus Areas and areas outside of Focus Areas within individual
riparian process domains. Additionally, two of the Focus Areas were not included in the riparian
sections: FA-141 (Indian River) and (FA-151) Portage Creek; these sites contained little, if any,
floodplain area and therefore were not relevant to the Riparian IFS study objectives. These two
sites were therefore removed during the initial riparian Focus Area determination process.
Fourth, preliminary delineation of riparian process domains was completed using a spatially
constrained cluster analysis (Legendre and Legendre 2012) of geologic and geomorphic data
gathered in ArcGIS from geo-rectified aerial imagery and LiDAR digital elevation map (2011
Matsu Ortho Imagery at 1:8000 scale, http://matsu.gina.alaska.edu/wms/imagery). In the Middle
River Segment, a total of 340 transects was placed and aligned perpendicular to the valley
bottom axis at 1/4-mile intervals from the proposed Watana Dam site (PRM 187.1) to Three
Rivers Confluence (PRM 102.4). At each transect, geomorphic variables were measured:
channel slope, confinement ratio (defined as the active channel width divided by the total
floodplain width), and channel types. Channel types assigned for this analysis included main
channel, side channel, split main channel, and braided main channel. Determinations of active
channel vs. off-channel geomorphic features were consistent with definitions developed in the
Fluvial Geomorphology Modeling Study (ISR Study 6.6) (Tetra Tech 2013). Vegetation data
were not included in this third step of the analysis by design. The geologic and geomorphic type
classification data were used in constrained agglomerative clustering, a spatially constrained
cluster analysis process, using Legendre’s package of functions for R (R Development Core
Team 2011), const.clust (http://adn.biol.umontreal.ca/~numericalecology/Rcode/) to group study
area channel reaches and segments into riparian process domains. The agglomerative clustering
algorithm begins with each transect as its own cluster, then iteratively joins the adjacent transects
that are most similar (smallest distance). The multivariate distance between two transects was
defined using the distance metric formalized by Gower (1971) and recommended by Legendre
(P. Legendre, Professor, Departement de sciences biologiques, Universite de Montreal, personal
communication, February 25, 2013). For continuous variables and ordered factors, the univariate
distance is the scaled difference │Xi – Xj│/max (difference). The multivariate distance is
simply the average of these distances for the three variables.
The clustering algorithm creates as many clusters as the user defines. For this study, the number
of clusters was defined as the minimum cross-validation residual error method as recommended
by Legendre in the const.clust package. Cross-validation is a resampling technique that
estimates the ratio of variation that is not explained by the cluster partition to the total variation
in the transect measurements. The cross-validation routine selects the best number of clusters to
minimize this unexplained variance.
Fifth, floodplain vegetation data were collected along the digitized transects established in the
third step described above. Each transect was segmented and vegetation was classified
according to Viereck Level III plant community type (Viereck et al. 1992) by the Riparian
Vegetation Study (Study 11.6). Lineal distances were computed for each discrete vegetation
community. Transect data describes the spatial distribution and abundance of plant communities
along the entire length of the Middle River Segment.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 8 February 2014 Draft
Finally, Viereck Level III vegetation types and type abundance were summarized for (1) each of
the riparian process domains (Devils Canyon was excluded); and 2) each of the eight Focus
Areas. The Focus Areas in each riparian process domain were then examined as to their
vegetation types, relative abundances, and representativeness relative to the entire riparian
process domain. Final 2013 Focus Area selection was described in the March 1, 2013 Focus
Area Technical Memorandum (R2 Resource Consultants [R2] 2013) and riparian vegetation
study analysis (Appendix A). A subset of five of the preliminary eight candidate Focus Areas
was selected that together capture variability of plant communities present in the study area.
4.2.2. Variances from Study Plan
No variances from the methods described in this component of the Study Plan occurred in the
2013 study season. Methods were refined from the RSP to the ISR as described in Section 4.2.1
above.
4.3. Characterize Seed Dispersal and Seedling Establishment
Groundwater and Surface Water Hydroregime Requirements.
Develop Predictive Model of Potential Project Operational
Impacts to Seedling Establishment (hereafter, Seed Dispersal
and Seedling Establishment)
Floodplain plant seed dispersal and seedling establishment are critical processes in floodplain
plant community succession that may be affected by hydro project operations (Braatne et al.
1996; Cooper et al. 1999; Rood et al. 2003). In this study dominant woody species seed
dispersal and seedling establishment hydrologic requirements are being determined through field
surveys and groundwater and surface water interaction measurement and modeling. The study
has two subtasks: (1) seed dispersal, hydrology, and local Susitna River valley climate synchrony
study; and (2) seedling establishment and recruitment study.
4.3.1. Synchrony of Seed Dispersal, Hydrology, and Local Susitna River Valley
Climate
Susitna River pioneer riparian tree and shrub species in the family Salicaceae, balsam poplar
(Populus balsamifera and Populus balsamifera ssp. trichocarpa, and any hybrids of these; also
commonly referred to as cottonwood) and willows (Salix spp.), are adapted to seasonal
snowmelt-driven spring peak flows in terms of timing of seed dispersal, newly deposited mineral
colonization substrates, and concordant near-surface floodplain groundwater conditions, all
necessary conditions for poplar and willow seedling establishment and recruitment (Figure 4.3-1;
Braatne et al. 1996; Mahoney and Rood 1998; Mouw et al. 2012). Project operations would
result in a reduction of June/July peak flows and might result in a reduction of associated
floodplain groundwater elevations necessary for dispersal and establishment of balsam poplar
and willow trees and shrubs. The timing of snowmelt spring flows, and of tree and shrub
seedling release and dispersal, is critical to successful establishment and maintenance of arid and
temperate riparian floodplain forests (Figure 4.3-2; Braatne et al. 1996; Mahoney and Rood
1998). The “recruitment box model,” an empirical model that captures balsam poplar and
willow seed dispersal, flow response, and recruitment requirements, has been successfully
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 9 February 2014 Draft
demonstrated on arid, semi-arid and temperate region rivers throughout North America
(Figure 4.3-2) (Mahoney and Rood 1998; Rood et al. 2003). The model characterizes seasonal
flow pattern, associated river stage (elevation), and flow ramping necessary for successful
balsam poplar and willow seedling establishment (Figure 4.3-1 and Figure 4.3-2). A recruitment
box model for balsam poplar and select willow species for the Susitna River will be developed
using 2 years of data to characterize the relationship between seed dispersal, timing, flow regime
and Susitna Valley climate. Study objectives, methods, and expected results are summarized in
Table 4.3-1.
Objectives of the seed dispersal, hydrology, and climate synchrony study are as follows:
1. Measure balsam poplar and select willow species seed dispersal timing.
2. Measure and model local Susitna River valley climate and associated seasonal peak flows
relative to balsam poplar and willow seed dispersal.
3. Develop a recruitment box model of seed dispersal timing, river flow regime, and balsam
poplar and willow seed dispersal and establishment.
4.3.1.1. Methods
AEA implemented the methods as described in the Study Plan with no variances.
To evaluate synchrony of balsam poplar and select willow species [feltleaf willow (Salix
alaxensis), Barclay’s willow (S. barclayi), and Sitka willow (S. sitchensis)] seed release, and
Susitna River natural flow regime, the following tasks were begun in 2013 and will continue in
Q2 to Q3 of the next study year: (1) a 2-year survey of seed release of balsam poplar and select
willow species; (2) development of a ‘degree-day’ climate model for the onset of seed release
relative to local temperature conditions using methods developed by Stella et al. (2006); and (3)
analysis of historic climate and Susitna River flow regime relationships. The results of the study
will identify flow regime timing conditions necessary to support riparian balsam poplar and
willow establishment on the Susitna River.
Four floodplain sites near existing meteorological stations in the Middle and Lower Susitna
River Segments (Figure 4.3-3) were selected for balsam poplar and willow species seed release
surveys. At each site, 6 dominant female balsam poplar trees and 6 to 12 willows were surveyed
weekly during the months of June and July. In the AEA approved Study Plan, seed release
observations were predicted to continue through the first 2 weeks of August; however, in 2013,
the peak seed release occurred earlier than expected and few seeds remained by the end of July.
Thus seed release observations were discontinued at the end of July.
Balsam poplar seed release was measured during each survey by summing 20-second counts of
open catkins from the top, middle, and bottom portion of each tree according to methods
developed by Stella et al. (2006). Due to the shrub growth form of willows an untimed count of
open catkins for each entire shrub was performed. Weekly surveys were halted once no open
catkins were visible on trees and shrubs or the count remained unchanged for several weeks
following peak seed release. Floodplain riparian plant community characteristics were sampled
for each floodplain seed dispersal site using vegetation sampling techniques outlined in the
Riparian Vegetation Study (see ISR Study 11.6, Section 4). Initial tree data and seed release
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 10 February 2014 Draft
timing data collected in 2013 were analyzed using protocols developed by Stella et al. (2006).
At all field sites, local air temperature measurements were collected from adjacent weather
monitoring stations (Figure 4.3-3). If no weather monitoring station had been established in the
vicinity of the seed release study site, temperature loggers (HOBO U23 Pro v2; Onset, Bourne,
MA) were installed inside a solar radiation shield approximately 1 meter (3.3 feet) above the
ground surface. A preliminary degree-day model using seed release observations and continuous
temperature records from the monitoring stations was developed using the first year of data
(Stella et al. 2006). This model will be re-run with data from 2 years of observations. A
recruitment box model (Figure 4.3-2); Mahoney and Rood 1998; Rood et al. 2003) will be
developed to evaluate the potential effects of Project operational flow scenarios on balsam poplar
and willow establishment.
4.3.1.2. Variances from Study Plan
No variances from the methods described in this component of the Study Plan occurred in the
2013 study season. Methods were refined from the RSP to the ISR as described in Section 4.3.1
above.
4.3.2. Seedling Establishment and Recruitment
Riparian vegetation in mountain river networks is adapted to a dynamic physical disturbance
regime, including flooding, summer desiccation, erosion, sediment burial, ice shearing and
freezing, wind, herbivory and, infrequently, fire (Naiman et al. 1998). Seedling establishment,
survival, and recruitment are critical phases in the development of floodplain plant communities
within this dynamic physical environment (Walker and Chapin 1986; Walker et al. 1986;
Karrenberg et al. 2002; Mouw et al. 2009, 2012; Rood et al. 2007). The goal of the seedling
establishment and recruitment study is to identify, measure, and model potential impacts of
Project operational changes to the groundwater, surface water, sediment, and ice regimes, and to
assess the effects on seedling establishment and recruitment within the active channel
margin/floodplain environment.
Identifying the spatial locations, and groundwater, surface water, and sediment requirements
under which new cohorts of dominant riparian plant seedlings establish, survive, and recruit on
the Susitna River floodplain is a critical element in evaluating potential floodplain vegetation
effects of Project operational alterations of the natural flow and sediment regimes. River ice
seedling interactions, an additional critical physical disturbance factor, will be investigated in the
Ice Process Modeling Study (see Section 4.4.2).
Seedling recruitment on the Susitna River floodplain occurs not only on new flood-deposited
sediments along channel and floodplain margins—the primary sites of balsam poplar, willow,
thinleaf alder (Alnus incana ssp. tenuifolia), and mountain alder (Alnus viridis ssp. crispa)
colonization—but also on sediment deposits within the developing and mature floodplain forest
(Helm and Collins 1997). Helm and Collins (1997) noted that within the Susitna River
floodplain forest, white spruce (Picea glauca) and paper birch (Betula papyrifera) seedlings
were found to establish, and recruit, on mineral soils associated with both floodplain surface
sediment deposits, ice-influenced sediment deposits, and tree windthrow mound soils. Also,
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 11 February 2014 Draft
white spruce and paper birch seedlings were observed growing on mounds of gravel and sand
apparently pushed onto the floodplain interior by ice flows.
Study objectives, methods, and expected results are summarized in Table 4.3-2. Objectives of
the seedling establishment study are as follows:
1. Map and characterize seedling establishment and recruitment of dominant woody riparian
species, balsam poplar, white spruce, paper birch, thinleaf and mountain alder, feltleaf
willow, and Barclay’s willow along lateral channel margins and floodplain surfaces. As
recommended by FERC (April 1 SPD), seedlings were assessed following the initial
spring peak flows (e.g., July) and again in September in 2013. The RSP required
seedling surveys to be conducted throughout the Focus Area, and Riparian Vegetation
Study sites, active channel margins, and floodplains. Upon field observations, it was
determined that current Focus Areas, collectively, were adequate to meet objectives of
the seedling establishment study. Therefore, seedling surveys occurred within Focus
Areas along lateral channel margins and floodplain surfaces.
2. Use a stratified random sampling approach, with variable plot sizes (Mueller-Dombois
and Ellenburg 1974), to sample mapped seedling polygons.
3. Identify seedlings to species, and measure seedling heights and density.
4. Describe and measure seedling site soil characteristics associated with seedling
establishment and recruitment (see Section 8.6.3.7 for methods).
5. Measure and model GW/SW hydroregimes associated with seedling establishment and
recruitment. Measure seedling xylem water source through isotopic analysis (see Section
8.6.3.6 for methods).
6. Investigate ice process seedling site interactions through empirical observations and ice
process modeling.
7. Develop a probabilistic model of seedling hydrologic, sediment, and ice regime
processes.
4.3.2.1. Methods
AEA implemented the methods as described in the Study Plan with the exception of variances
explained below (Section 4.3.2.2).
Following on-the-ground observations and reconnaissance surveys conducted throughout the
study area in Q2 2013, sampling methods were refined to characterize seedling establishment
and recruitment patterns for dominant riparian woody species, including balsam poplar, white
spruce, paper birch, thinleaf and mountain alder, feltleaf willow, and other willow species.
Seedling reconnaissance surveys were completed by helicopter and on foot in Focus Areas FA-
104 (Whiskers Slough), FA-113 (Oxbow 1), FA-115 (Slough 6A), FA-128 (Slough 8A), FA-138
(Gold Creek), and FA-144 (Slough 21) to identify patterns of seedling distribution. Locations of
dense seedling populations were mapped with a hand-held GPS unit. Seedlings of balsam poplar
and willow species were found in large first-year cohort (seedlings having the same year of
establishment) populations along lateral margins of mid-channel islands and occasionally along
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 12 February 2014 Draft
lateral margins of the main and side channels. White spruce and paper birch seedlings were
found to be establishing on tree tip-up mounds (pit and mound topography) throughout older
floodplain surfaces as observed by Helm and Collins (1997) and described in Harza-Ebasco
(1985). White spruce seedlings were also found within younger seral stages on mid-channel
islands.
Three survey methods were selected to characterize these widely divergent establishment and
recruitment patterns: (1) first year (0+) balsam poplar and willow establishment; (2) clonal
balsam poplar and willow recruitment; and (3) white spruce and birch establishment. Methods
for each study are described below.
In the Study Plan, seedlings were defined as plants with stems less than 1 meter (3.3 feet) in
height. However, following reconnaissance surveys, it became clear that poplar and willow
establishing on lateral margins of mid-channel islands are subject to frequent disturbance by ice.
Given the degree of ice shearing disturbance and sediment burial of stems, height appears not
necessarily to be directly related to age of the stem. These trees and shrubs, due to annual ice
shearing and sediment deposition, may remain less than 1 meter (3.3 feet) in height for many
years and are not true seedlings. Moreover, ice laydown and burial may result in stems that are
less than 1 meter in height but are actually clones associated with much older buried “parent”
stems. It is difficult to differentiate clonal vs. sexual recruitment with non-destructive sampling
methods. Similarly, as birch and spruce often establish below a full canopy, it may take one or
more decades to exceed 1 meter (3.3 feet) in height. Therefore, the first year (0+) balsam poplar
and willow establishment study was restricted to documenting current cohort of seedlings less
than 1 year old. The spruce and birch establishment and recruitment study documented
distribution of all age classes of spruce and birch regardless of height.
Results of seedling and soils and microtopography characterizations will be used to assess
seedling groundwater, surface water, and ice regime relationships using 1-D/2-D, MODFLOW
and ice process modeling results from the Groundwater, Fluvial Geomorphology Modeling, and
Ice Processes studies (Studies 7.5, 6.6, and 7.6, respectively). A probabilistic model of seedling
occurrence and GW/SW, sediment, and ice regimes will be developed using techniques and
methods described in Franz and Bazzaz (1977), Rains et al. (2004), Henszey et al. (2004), Baird
and Maddock (2005), and Maddock et al. (2012).
The results of Focus Area modeling will be scaled-up to the riparian process domains using
spatially explicit GIS models as described in Section 4.2.
4.3.2.1.1. First Year (0+) Balsam Poplar and Willow Seedling Establishment
As described above, areas of dense populations of seedlings were first mapped along lateral
channel and floodplain margins within six Focus Areas and seedling patches were stratified into
five floodplain terrain types (island head, island tail, slough, main channel, side channel). Sample
sites were randomly selected for further study. Second, 0.25-square-meter (2.7-square-foot)
quadrats were laid out at 1-meter (3.3-foot) intervals along randomly located transects along a
baseline established parallel to the channel. Two to three transect locations were randomly
located extending normal to the channel from lowest extent of seedling occurrence (typically the
edge of water) to full vegetative canopy cover in adjacent floodplain forest or shrub community.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 13 February 2014 Draft
Each transect was permanently marked with a rebar pin and buried magnetic marker for annual
repeat measurements. Third, within each plot, poplar and willow first-year germinants/seedlings
were counted to estimate abundance and density. In addition to counting target woody seedlings,
all herbaceous plants within the plots were identified to species. Aerial percent cover and stem
heights for tree or shrub seedlings were measured. At each 0.25-square-meter (2.7-square-foot)
quadrat the following data were collected:
• Sediment texture was recorded as percent cover of quadrat gravel or cobble vs.
percent cover by sand or silt.
• Depth to gravel/cobble layer was measured using a 2-meter (6.6 ft) tile probe (AMS,
Inc.).
• Elevation of each quadrat was surveyed with a level. An intermediate benchmark
was set that was later surveyed with survey-grade RTK and tied into the Project
datum.
• Soils were collected to a depth of 10 centimeters (3.9 inches) at each seedling plot
with seedlings present in the September 2013 survey. Soil particle size will be
measured using standard hydrometer analysis (Soil Survey Staff 2009).
Seedlings were collected in September 2013 at a sub-sample of Focus Area seedling sites for
xylem isotopic analysis to identify source of water (see Section 4.5). Excavated seedling root
lengths were measured. In addition, shallow groundwater wells were installed in pairs along a
sub-sample of seedling transects. Shallow groundwater wells consisted of perforated 2-inch-
diameter pipe installed as deep as possible below the surface and extending into the cobble
subsurface. Fifteen wells were installed along transects at depths ranging from 1.6 to 4.6 feet
below the floodplain surface. Well-water level depths were measured relative to the floodplain
elevation and adjacent surface water levels. Water level measurements were conducted at least
three times in Q3 2013.
As recommended by the FERC (April 1 SPD), first year (0+) seedling establishment sampling
was completed following the initial spring peak flows in late July and early August 2013, and
seedling presence sampling was repeated in early-mid September 2013. Year 2 monitoring will
occur in late July and September during the next year of study.
4.3.2.1.2. White Spruce and Paper Birch Establishment
White spruce and paper birch recruitment was characterized along 8-meter-wide belt transects
established on mid-channel islands in 2013. At each surveyed island, two transects were placed
randomly along a baseline normal to the channel at the island head. Transects were extended the
entire length of the island parallel to the channel. Location of the start and end points of each
transect was collected with a hand-held GPS unit capable of sub-meter accuracy. Diameter at
breast height (DBH) and height of each spruce tree within the 8-meter-wide (26.25 ft) belt
transect were recorded. Additional white spruce and paper birch transects will be sampled in
both lateral floodplain and mid-channel island locations on older floodplain surfaces.
To characterize age structure of white spruce on each sampled island, six to ten spruce seedlings,
saplings, and/or trees were selected randomly and sampled using standard dendrochronologic
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 14 February 2014 Draft
techniques for tree and shrub sampling and growth ring measurements (Fritts 1976) as described
in Section 4.5.1. At each white spruce either collected or cored for age determination, depth of
sediment above the root collar and depth to gravel/cobble was measured with a tile probe.
Additionally, soil sediment samples were taken to a depth of 20 centimeters (7.9 inches) with a
5-centimeter (2-inch) diameter soil corer (AMS). Soil sediment texture was described, and
buried organic horizon depths measured, using standard NRCS methods.
Because paper birch rarely establish on mid-channel island floodplains, white spruce was the
primary focus of the seedling surveys study in 2013. Additional transects will be established
across the lateral floodplain in the next study year using similar methods to quantify floodplain
and terrace spruce and birch recruitment within riparian Focus Areas.
4.3.2.2. Variances from Study Plan
AEA implemented the methods as described in the Study Plan with the exception of the variance
explained below. Methods were refined from the RSP to the ISR as described in Section 4.3.2
above.
In the Study Plan, seedlings were defined as plants with stems less than 1 meter (3.3 ft) in height.
However, following reconnaissance surveys, it became clear that poplar and willow establishing
on lateral margins of mid-channel islands are subject to frequent disturbance by ice. Given the
degree of ice shearing disturbance and sediment burial of stems, height appears not necessarily to
be directly related to age of the stem. These trees and shrubs, due to annual ice shearing and
sediment deposition, may remain less than 1 meter (3.3 ft) in height for many years and are not
true seedlings. Moreover, ice laydown and burial may result in stems that are less than 1 meter
in height but are actually clones associated with much older buried “parent” stems. It is difficult
to differentiate clonal vs. sexual recruitment with non-destructive sampling methods. Similarly,
as birch and spruce often establish below a full canopy, it may take one or more decades to
exceed 1 meter (3.3 ft) in height. Therefore, the first year (0+) balsam poplar and willow
establishment study was restricted to documenting current cohort of seedlings less than 1 year
old. The spruce and birch establishment and recruitment study documented distribution of all
age classes of spruce and birch regardless of height.
This change in methodology is a clarification of study methods that was determined based on on-
the-ground observations and site-specific conditions that were not understood prior to the 2013
field season. To characterize poplar and willow clonal establishment, a clonal reproduction
study for balsam poplar and willow will be conducted in identified and mapped high frequency
ice disturbance zones. This study is a cross-over with the ice processes study element
(Section 4.4) as it addresses both poplar and willow establishment processes and ice effects on
these processes. Fieldwork for this study will be completed in the next study year using belt
transect quadrats. Balsam poplar and willow less than 1 meter (3.3 ft) in height will be
excavated to determine presence or absence of clonal connection to a larger buried parent stem.
Height above the floodplain surface and depth of burial will be measured.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 15 February 2014 Draft
4.4. Characterize the role of river ice in the establishment and
recruitment of dominant floodplain vegetation. Develop
predictive model of potential Project operational impacts to ice
processes and dominant floodplain vegetation establishment
and recruitment (hereafter, River Ice Effects on Floodplain
Vegetation)
Although the role of fluvial disturbance (erosion and sediment deposition) in the development of
floodplain vegetation has been well investigated (Naiman et al. 1998; Rood et al. 2007), the role
of river ice processes has seen little study (Engstrom et al. 2011; Prowse and Beltaos 2002;
Prowse and Culp 2003; Rood et al. 2007). The effects of river ice disturbance of floodplain
vegetation have been observed in the Susitna River, and reported anecdotally, in Helm and
Collins (1997). The 2012 Riparian Botanical Survey team observed extensive evidence of ice
disturbance to floodplain trees, and soils, in the form of tree ice-scars, mechanically-disturbed
soil stratigraphy, and floodplain gravel deposits throughout the Middle and Lower Susitna River
surveys (Figure 4.4-1, Figure 4.4-2, and Figure 4.4-3).
Impacts of ice-related processes to riparian habitat typically occur during break-up when ice
scours channel and floodplain surfaces (Prowse and Culp 2003). During break-up, ice
accumulation in meander bends can create ice dams elevating backwater surfaces, forcing
meltwater to bypass the bend and scour a new meander cutoff and generating new side channels
(Prowse and Culp 2003). Elevated backwater, resulting from ice dams, may also float ice blocks
onto and through vegetated floodplain surfaces, causing mechanical shearing effects, including
tree ice-scarring and abrasion, removal of floodplain vegetation, shearing disturbance of
floodplain soils, and burial of floodplain vegetation by sediment deposits (Engstrom et al. 2011;
Rood et al. 2007; Prowse and Culp 2003).
4.4.1. Empirical Studies of River Ice and Floodplain Vegetation
AEA will rely on multiple lines of evidence to address the question of vegetation response to ice
shearing influence on the Susitna River floodplain. First, ice vegetation impacts (tree ice-scars)
will be observed, mapped, and aged (using dendrochronologic techniques), and gravel floodplain
deposits will be mapped throughout the study area to develop a map of river ice floodplain
vegetation interaction domains. Preliminary tree ice-scar mapping was begun during the 2012
Riparian Botanical Survey, and early October 2012 Focus Area reconnaissance. Mapping
continued in Q2 and Q3 2013 and will be continued throughout the next riparian field season.
Second, local residents will be interviewed concerning their knowledge of spatial locations of
historic ice dams, years of significant ice occurrence, and other anecdotal historical information
concerning ice on the Susitna River. From these two sources of information, a map will be
created of Susitna River ice process floodplain vegetation effect domains. The ice process map
will be used to (1) inform riparian process domain delineation (see Section 4.2); and (2) develop
a floodplain vegetation study to compare floodplains affected by ice with those un-impacted by
ice, similar to the approach of Engstrom et al. (2011).
Floodplain vegetation surveys were initiated in 2013. These surveys were designed to
quantitatively measure (stratified random sampling of mapped floodplain vegetation ice shear
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 16 February 2014 Draft
process zones) and statistically describe and compare vegetation characteristics associated with
floodplains experiencing ice shear events and floodplain vegetation without observed ice
influence. The vegetation study design builds on the design and results of Engstrom et al. (2011)
where they studied and assessed the effects of anchor ice on riparian vegetation. Engstrom and
others found that species richness was higher at sites affected by anchor ice than at sites where
anchor ice was absent, suggesting that ice disturbance plays a role in enhancing plant species
richness (Engstrom et al. 2011).
The objective of the ice effects vegetation study is to quantitatively describe floodplain plant
community composition, abundance, age, and spatial pattern to assess the role and degree of
influence ice processes have on Susitna River floodplain vegetation. The results of the study will
be used to assess how floodplain vegetation pattern and process may change with Project
operation alterations of the natural ice process regime.
4.4.2. Ice Process Modeling
The Ice Process Study will develop and calibrate a dynamic thermal and ice processes model
(see ISR 7.6). The ice process modeling study will provide the riparian ice vegetation study with
estimated horizontal and vertical zones of ice formation, ice thickness, and floodplain impact
zones. Model output will be used in conjunction with the tree ice-scar survey data to
(1) empirically test model output with mapped riparian domains of ice floodplain vegetation
interaction; and (2) model changes in locations and types of ice formation processes due to
Project operations. Together, the mapped ice influence zones, empirical studies of vegetation/ice
interactions, and modeling confirmation and prediction will be used to understand and evaluate
the influence of Project operational flows on ice and floodplain vegetation interactions.
Study objectives, methods, and expected results are summarized in Table 4.4-1.
The objectives of the ice processes floodplain vegetation interaction and modeling study are as
follows:
1. Develop an integrated model of ice process interactions with floodplain vegetation.
2. Conduct primary research to identify the effects of ice on floodplain vegetation within
mapped Susitna River ice floodplain impact zones.
3. Provide Project operational guidance on potential effects of operations flow on ice
formation and floodplain vegetation development.
4.4.3. Methods
AEA implemented the methods as described in the Study Plan with no variances.
The following methods are being used to quantify interactions and effects of ice on floodplain
vegetation:
1. Mapping of ice floodplain vegetation interactions throughout the study area.
a. Tree Ice-Scar Mapping
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 17 February 2014 Draft
Tree ice-scars were surveyed in 2013 along the Middle River Segment of the Susitna
River (PRM 102–146) during September and early October. Mapping was conducted
via jet boat using a Trimble 2008 GeoXH with a mounted external antenna and off-set
laser (TruPulse 360 Laser). Boat survey protocol was to stop every 0.2 mile where
the nearest tree with an ice-scar was surveyed. If no ice-scarred trees were visible,
the floodplain surface elevation was surveyed. Tree ice-scar measurements included
(1) height of tree ice-scar; (2) height of floodplain surface at the base of the tree; (3)
height of floodplain above the water surface; and (4) horizontal location of the tree or
floodplain surface. Ocular counts of the number of trees with visible ice-scars were
made between each 0.2-mile stopping point while the boat traveled slowly along the
shoreline. Channel reaches not accessible by jet boat (e.g., shallow water, rocky
channel substrate) were mapped as inaccessible. All GPS location data were post-
processed with differential corrections using Trimble software and mapped on aerial
photographs.
b. Tree Ice-Scar Dendrochronology
Ice-scarred trees were sampled to determine the year of the ice-scarring event and to
develop an ice/floodplain interaction chronology. Scarred trees were sampled with a
16-inch chainsaw for dendrochronologic analyses (Fritts 1976; Stoffel and
Bollschweiler 2008). Tree wedges were cut into tree bole ice-scars (Figure 4.4-4).
Additional ice-scarred tree measurements included (1) height of tree ice-scar;
(2) height of floodplain surface at the base of the tree; (3) height of floodplain above
the water surface; and (4) horizontal location of the tree or floodplain surface.
Measurements were made with hand tape and surveyed from the jet boat using a
Trimble 2008 GeoXH with mounted external antenna and TruPulse 360 Laser. Tree
location GPS data were differentially corrected using Trimble software and mapped
on aerial photographs.
Tree wedges will be sanded using 200-600-grade sandpaper and growth rings counted
and measured using standard dendrochronologic techniques (Fritts 1976). All tree-
wedge samples will be photographed for archival purposes.
2. Aerial (via helicopter) 2013 mapping of ice break-up observations of local, sub-reach
scale, floodplain vegetation stand-scale ice disturbance effects. Analysis of floodplain
disturbance from 2013 ice break-up events.
3. Interviews of local Susitna River residents concerning knowledge of ice-dam locations
and ice process effects.
4. Comparative quantitative vegetation study of ice effects on identified ice floodplain
impact and un-impacted zones. Methods will build on those presented in Engstrom et al.
(2011).
5. Final ice vegetation field sampling methodology was developed in Q2, Q3 2013 as
described above.
6. Integration of ice process modeling results with empirical ice vegetation mapping and ice
vegetation interaction studies.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 18 February 2014 Draft
4.4.4. Variances from Study Plan
No variances from the methods described in this component of the Study Plan occurred in the
2013 study season. Methods were refined from the RSP to the ISR as described in Section 4.4.1
above.
4.5. Characterize the role of erosion and sediment deposition in the
formation of floodplain surfaces, soils, and vegetation.
Develop a predictive model of Project operations changes to
erosion and sediment deposition patterns and associated
floodplain vegetation (hereafter, Floodplain Stratigraphy and
Floodplain Development)
The dynamic of channel migration—sediment transport, floodplain erosion, and sediment
depositional patterns—is a critical physical process directly affecting floodplain soil
development and vegetation establishment and recruitment throughout alluvial segments of the
river network (Richards et al. 2002). The life history strategies and establishment requirements
of floodplain plant species are adapted to natural flow and sediment regimes (Braatne et al. 1996;
Naiman et al. 1998; Karrenberg et al. 2002). As such, alterations of natural hydrologic and
sediment regime seasonal timing, magnitude, frequency, and duration may have effects on plant
species establishment, survival, and recruitment (Braatne et al. 1996). The goal of this study is
to characterize the role of erosion and sediment deposition in evolution of floodplain planform,
soil development, and trajectory of plant community succession, especially vegetation
establishment stage. This study, in coordination with the Fluvial Geomorphology Modeling
Study (see Study 6.6), investigates the geomorphic evolution of the Project area floodplain with
an emphasis on floodplain sediment deposition, stratigraphy, soil development, and associated
plant community succession. Historic sediment deposition rates will be measured throughout the
study area river network and variations in floodplain forming processes will be assessed.
Finally, a predictive model will be developed with the Fluvial Geomorphology Modeling Study
(see Study 6.6) to assess Project operational effects on hydrologic and sediment regimes, and
effects on soil and floodplain plant community development.
In a river that meanders through a wide valley, such as the Susitna River, erosion on one side of
the channel will be balanced by deposition on the opposite bank as the river migrates laterally.
Disturbance to riparian habitat on the eroding bank will be balanced by opportunities for
recruitment on the point bar. This type of geomorphic process maintains the characteristic range
of floodplain surface elevations and vegetation age classes contributing to the diversity of
floodplain vegetation composition and structure (Naiman et al. 1998). The rate of channel
migration may be impacted by Project operations, with secondary impacts on the riparian
community. The Fluvial Geomorphology Modeling Study will assess Project alterations to
downstream channel bed and floodplain surface elevations through sediment transport modeling
and analyses. These potential changes will be provided to the Riparian IFS. Development of the
study design, modeling, and methods has been coordinated closely with Fluvial Geomorphology
Modeling Study (Study 6.6), Ice Processes Study (Study 7.6), and Riparian Vegetation Study
(Study 11.6) study teams (Table 4.5-1).
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 19 February 2014 Draft
Study objectives, methods, and expected results are summarized in Table 4.5-1.
The objectives of the study are as follows:
1. Measure the rates of channel migration, and floodplain vegetation disturbance or
turnover, throughout the study area.
2. Measure the rates of sediment deposition, and floodplain development, throughout the
study area.
3. Assess/model how Project operations will affect changes in the natural sediment regime,
floodplain depositional patterns, and soil development throughout the study area.
4. Assess/model how Project operation induced changes in sediment transport and soil
development will affect floodplain plant community succession.
4.5.1. Methods
AEA implemented the methods as described in the Study Plan with no variances.
The following methods are being used to characterize floodplain sediment and depositional
processes.
1. Floodplain soils and stratigraphy were sampled throughout the study area at Integrated
Terrain Unit (ITU) plots located using a stratified random approach (see ISR Study 11.6.;
Section 4). At each ITU plot, soil pits were excavated to a depth of 60 centimeters and
standard NRCS methods were used to describe soil profiles as described in the Riparian
Vegetation ISR (Study 11.6.; ISR Section 4).
2. Thirteen sediment cores were collected during 2013 consisting of five cores from FA-104
(Whiskers Slough) and eight cores from FA-115 (Slough 6A) for sediment isotope
geochronological analysis. The sediment sample sites at both Focus Areas were located
at ITU plot floodplain locations along transects perpendicular to the river. Topographic
transects and plot locations were surveyed using RTK GPS survey instrumentation and
tied into the Project survey datum. Sediment cores were collected with a thin-walled soil
probe for 210Pb and 137Cs analysis (AMS Inc.) that is 91 centimeters (35.8 inches) long
with a diameter of 2.5 centimeters (1 inch). Recovery of sediment cores was generally
excellent with the longest cores, typically 60–130 centimeters (23.6–51.2 inches) in
length depending on depth to cobble/gravel refusal layer. In shorter cores, a hard
sediment plug blocked the cutting edge of the probe, preventing further sediment entry.
3. Sediment core 210Pb and 137Cs laboratory geochronology analyses will be conducted
using standard methods (Aalto 2003; Aalto et al. 2008). Per the FERC approved Study
Plan, particle size analysis by horizon and every centimeter will be conducted. This
provides detail at a finer resolution than would be achieved with analysis by horizon
alone. Selected cores will be sectioned at 2-centimeter (0.8 in) intervals for both particle
size and isotope analyses (Aalto et al. 2003; Aalto et al. 2008). Sediment isotope
laboratory results from 2013 data will be used to evaluate sediment geochronology
methods and to determine the sediment study design for the next year of study. This
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 20 February 2014 Draft
existing methodology captures the horizon profile analysis recommended in the FERC
Study Plan Determination.
4. Woody species were sampled and aged at each ITU sample plot to determine year of
origin. Standard dendrochronologic techniques were applied for tree and shrub sampling
and growth ring measurements (Fritts 1976). Details of these methods are described
below.
5. In addition to collecting tree-core samples from representative trees and shrubs, plant
community characteristics were described at each ITU sample plot per methods outlined
in the Riparian Vegetation Study (ISR Study 11.6.; Section 4).
At each ITU plot, two to three trees and shrubs per species were sampled for age determination.
Tree and shrub samples were taken with either an increment borer, or, for smaller diameter
stems, by cutting the shrub or sapling stem and removing a stem section for laboratory analysis.
Increment cores (two per tree) were collected from each tree. For each tree sampled, floodplain
sediment was excavated to uncover the stem root collar and depth of sediment aggradation was
measured for further age estimation. Woody species seedlings for each dominant species were
excavated, heights measured, stems sectioned at the root collar, and annual rings measured under
a dissecting microscope. A regression analysis will be conducted to assess the relationship
between stem age and seedling height. The results will be used to add additional years to trees to
account for height of core sample above the root collar.
Tree cores were taken as close to the ground surface as possible, generally 30 centimeters (11.8
cm) or less above ground surface. The total height of the tree core sample above the root collar
was calculated and used to estimate additional years to estimate tree year of origin.
Increment cores were mounted on pieces of 1-inch-by-2-inch wood and sanded with variable
grades of sandpaper following standard methods described in Fritts (1976). Ring width
measurements will be made, and annual years counted, for both the tree cores and stump sections
using a dissecting microscope. Individual trees will be cross-dated, if possible, using standard
methods (Fritts 1976).
4.5.2. Variances from Study Plan
No variances from the methods described in this component of the Study Plan occurred in the
2013 study season. Methods were refined from the RSP to the ISR as described in Section 4.5.1
above.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 21 February 2014 Draft
4.6. Characterize natural floodplain vegetation groundwater and
surface water maintenance hydroregime. Develop a predictive
model to assess potential Project operational changes to
natural hydroregime and floodplain vegetation (hereafter,
Riparian GW/SW Hydroregime)
4.6.1. Riparian GW/SW Hydroregime Overview
Water sources for the establishment and maintenance of floodplain vegetation include
precipitation, groundwater, and surface water (Cooper et al. 1999; Rood et al. 2003). Identifying
both floodplain plant water sources and the groundwater/surface water (GW/SW) hydroregime
associated with critical riparian plant species life stages is necessary to (1) characterize natural
floodplain vegetation establishment and hydrologic requirements for maintenance; and
(2) evaluate effects of Project operations on these hydroregimes and associated plant
communities.
The goal of the floodplain vegetation GW/SW interaction modeling effort is to statistically
characterize the relationship between the natural floodplain groundwater and surface water
hydroregime, and associated floodplain plant communities, and to use this model to evaluate
Project operational effects on floodplain vegetation. This investigation will (1) characterize
water sources of dominant floodplain woody plant species establishment and maintenance life
stages through stable isotope analyses of precipitation, river water, groundwater, soil water, and
xylem water; (2) develop a floodplain GW/SW model; and (3) develop floodplain vegetation-
flow response models.
Regional and local groundwater flow systems are important to floodplain vegetation
(Figure 4.6-1). Seasonal river stage fluctuations generate transient GW/SW interactions at a
local scale under and adjacent to the river, including side channels, side sloughs, and upland
sloughs (Figure 4.6-2). Developing conceptual models and numerical representations of the
GW/SW interactions, coupled with important processes in the unsaturated zone, will help
evaluate the natural variability in the Susitna River floodplains, and reveal how various Project
operations could result in alterations of floodplain plant community types (Rains et al. 2004).
Riparian woody species establishment has been associated with surface water flooding,
precipitation, and groundwater (Braatne et al. 1996; Cooper et al. 1999; Rood et al. 2003).
Riparian floodplain vegetation maintenance relies on precipitation, surface water, and
groundwater as water sources (Cooper et al. 1999; Rood et al. 2003; Henszey et al. 2004).
Recent research has demonstrated that poplar species (genus Populus) are facultative
phreatophytes, deep-rooted plants that extract their water from the saturated zone or capillary
fringe of the saturated zone, and opportunistic (facultative) with respect to water source (Rood
et al. 2011). Poplar species have been shown to develop a range of root system depths
depending upon moisture availability. Shallow rooting systems typically develop in moist
temperate climates and deeper root systems often develop in arid to sub-arid environments (Rood
et al. 2011). Floodplain groundwater depths have also been demonstrated to control floodplain
plant community composition, species richness, and structure (Henszey et al. 2004; Baird and
Maddock 2005; Mouw et al. 2009). Project operations may alter flows of the Susitna River
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 22 February 2014 Draft
seasonally (higher flows in winter time and lower flows in summer) and daily (resulting from
load following), which may affect floodplain shallow aquifer water elevations. The riparian
GW/SW study is designed to measure and evaluate the relationship between riparian floodplain
plant communities and the natural GW/SW hydroregime, and to assess the floodplain aquifer
response to flow modifications resulting from Project operations. The results of this study will
be scaled-up from the Focus Areas to their respective riparian process domains to provide a
flow-response function for the entire study area.
Study objectives, methods, and expected results are summarized in Table 4.6-1.
The objectives of the riparian GW/SW study are to:
1. Determine the seasonal sources of water for dominant riparian plant species and major
riparian plant community types.
2. Define the natural GW/SW hydroregimes associated with the dominant riparian plant
species and plant community types.
3. Determine how floodplain shallow aquifer water levels respond to Project operations.
4. Determine whether and the extent to which changes in GW/SW resulting from Project
operations will affect riparian plant community composition, abundance, spatial
distribution, and structure.
4.6.2. Methods
AEA implemented the methods as described in the Study Plan with no variances.
4.6.2.1. Stable Isotope Analyses
The predominant water source utilized by dominant woody and herbaceous species found along
the Susitna River will be directly determined from stable isotope analyses of groundwater, soil
water, precipitation, and plant xylem water. Stable isotopes of hydrogen and oxygen will be
assessed. Due to inherent properties of isotopes (Lajtha and Marshall 1994), many
biogeochemical processes have a specific isotopic signature measured as the ratio of heavy to
light isotopes (Dawson et al. 1993; Lajtha and Marshall 1994). The use of isotopes provides a
minimally destructive method for measuring water acquisition by plants. Within the soil profile,
there are naturally occurring gradients of isotopic abundance in soil water (Dawson et al. 1993).
Because plants do not discriminate against heavy isotopes during water uptake, xylem water in
non-transpiring plant tissues retains the isotopic signature of the water source from which it was
derived (Flanagan and Ehleringer 1991). Thus, isotopic abundance in xylem sap corresponds to
the range of isotopic composition of all water taken up by plant roots, and can determine the
source of a plant’s water uptake (Dawson et al. 1993; Dawson et al. 2002).
In order to determine isotope signatures of available water sources, water samples were collected
during 2013 for precipitation, groundwater, and adjacent river water. Precipitation samples for
stable isotope analyses were collected at FA-104 (Whiskers Slough) and FA-128 (Slough 8A)
with a custom-made oil-type collector following the design in Scholl (2006). Because water in a
container open to the atmosphere immediately begins to change in isotopic composition due to
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 23 February 2014 Draft
evaporation and exchange with ambient vapor (Ingraham and Criss 1993), evaporation and
exchange are minimized in the oil-type collector, which is designed to inhibit evaporation.
Precipitation samples were collected in 20-milliliter plastic scintillation vials and kept frozen
until isotope analysis could be completed. Samples will be filtered to remove any oil prior to
analysis.
Groundwater samples were collected in September 2013 from linear transect arrays of
groundwater wells placed at the Focus Areas (see ISR Study 7.5). Wells were purged three times
prior to sample collection using a hand crank ballast pump to ensure fresh groundwater in the
well (Cooper et al. 2003). Samples were pumped directly from the well to 20-milliliter plastic
scintillation vials. River water samples were collected in flowing current. Groundwater and
river water sample vials were filled completely to eliminate headspace above the water, sealed
tightly with caps, and covered with parafilm to reduce the possibility of fractionation after
samples were collected. Samples will be kept frozen until isotope analysis can be completed.
Plant water sampling was conducted within different canopy cover types along GW/SW
transects. A minimum of eight samples was collected per species at every canopy cover type
sampled within a Focus Area. Plant water samples were collected through a combination of
branch clipping and increment bore samples. Small shrubs and herbaceous species were sampled
by collecting branch clippings. Stable isotope analysis of deuterium (2H) and oxygen (18O) ratios
will be conducted for dominant woody and herbaceous species using standard methods (Cooper
et al. 1999; Flanagan and Ehleringer 1991; Dawson and Ehleringer 1991).
The isotope analysis can help determine the rooting depth at which plants uptake water. Xylem
water has been demonstrated to reflect isotopic composition of the source water taken up by
roots (Flanagan and Ehleringer 1991; Dawson and Ehleringer 1991). Shallow soil layers
submitted to higher evaporative demands tend to be enriched in heavy isotopes relative to deeper
soil water layers (Dawson et al. 1993). However, natural abundance typically does not allow the
distinction of differences in rooting depth from 30 to 50 centimeters (LeRoux et al. 1995;
Jackson 1999; Ludwig et al. 2004; Kulmatiski et al. 2006). In order to create a reliable
evaporation profile, soil sampling was completed in 2013 in four locations repeated three times
during the growing season (June, July, and September). Soil samples were collected in 30-
centimeter increments from 0 to 150 centimeters using a 5.08-centimeter-by-30.48-centimeter (2-
inch-by-12-inch) diameter steel split spoon soil sampler (AMS, American Falls, ID). Cores were
divided out of the sampler into the following samples: 0-5, 5-10, 10-15, 15-20, 20-30, 30-40,
40-50, 50-60, 60-70, 70-80, 80-90, 90-100, and 100-150 centimeters. Samples were thoroughly
mixed for each sampling interval. A 12-milliliter glass tube was filled approximately half full
(6 milliliters) with soil from each sampling interval and frozen until samples could be analyzed.
The rest of the sample will be retained for root biomass analysis, as described below.
4.6.2.2. Characterization of Rooting Depths
Information concerning the depth of the root zone of dominant floodplain plants is needed to
accurately model groundwater, capillary fringe, and floodplain plant relationships. In 2013, the
rooting depth of dominant floodplain plants were measured through (1) a riverbank survey to
observe and measure depth profiles of recently exposed root systems following Rood et al.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 24 February 2014 Draft
(2011), and (2) collection of soil samples to determine root mass per unit area within the soil
profile.
The riverbank root surveys were conducted between PRM 102 and PRM 144 to rapidly observe
rooting profile of as many trees as possible. Rooting depth observations will be combined with
observations from trench excavations completed in the next study year. When all observations
are complete, root zone excavation and riverbank root zone survey data will be statistically
summarized to provide individual plant species and plant community type root zone depth
characterization for use in GW/SW modeling.
In Q2 – Q3 2013, soil samples were collected for quantification of root mass within the soil
profile. Root samples were collected at different vegetation cover types across FA-104
(Whiskers Slough) and FA-128 (Slough 8A) in conjunction with plant and soil isotope samples.
As described above, soil samples were taken using a 5.08-centimeter-by-30.48-centimeter
(2-inch-by-12-inch) diameter steel split spoon soil sampler at the following depths: 0-5, 5-10,
10-15, 15-20, 20-30, 30-40, 40-50, 50-60, 60-70, 70-80, 80-90, 90-100, and 100-150 centimeters.
Soil was washed away from roots and roots will be kept frozen until they can be processed (dried
and weighed) in a laboratory to determine root biomass by depth.
To determine available moisture within the soil profile, soil water content was measured using
content reflectometers at specific soil depths (Model CS650, Campbell Scientific, Inc., Logan
UT). Soil water content sensors were installed at 5, 10, 20, 50, 110, and 200 centimeters and at
5, 10, 25, 44, 65, and 85 centimeters in depth at FA-104 (Whiskers Slough) and FA-128 (Slough
8A), respectively. The asymmetric levels were chosen to more accurately represent vertical
variation in the rooting depths (Wilson et al. 2001).
4.6.2.3. GW/SW and Riparian Vegetation Modeling
Relationships between GW/SW and riparian vegetation will be developed using MODFLOW
(Harbaugh 2005) and the associated RIP-ET (riparian-evapotranspiration MODFLOW package;
Maddock et al. 2012).
Focus Area GW/SW sampling is designed to measure, and evaluate GW/SW hydroregime for all
floodplain plant community types and successional stages, including plant establishment, plant
recruitment, and mature forest vegetation. The sampling approach and design includes transects
and arrays of groundwater wells and surface water stage stations. Complete groundwater
sampling design details can be found in the Groundwater Study (see ISR Study 7.5, Section 4).
Riparian plant community field data were collected in 2013 and additional data will be collected
in the next study year, in coordination with the Riparian Vegetation Study (see ISR Study 11.6).
4.6.2.4. Plant Transpiration
Data collection to characterize plant transpiration processes was initiated in 2013 using two
methods: (1) continuous measurements of sap flow velocity made for woody species using the
Grainer’s Thermal Dissipation Probe (TDP) method (Granier 1987); and (2) direct leaf-level
stomatal conductance measurements collected for herbaceous and small shrub species using a
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 25 February 2014 Draft
solid-state leaf porometer (SC-1; Decagon Devices, Pullman, WA, USA). Detailed methods are
provided below.
4.6.2.4.1. Sap Flow Measurement
Sap flow velocity of representative tree species, and size ranges, were measured for determining
tree and plant community type transpiration rates for input into the MODFLOW groundwater
model. In 2013, data collection was initiated to develop plant transpiration flux curves for five
dominant floodplain woody plant species, Populus balsamifera, Betula papyrifera, Picea glauca,
Alnus incana ssp. tenuifolia, and Salix species. Sap flow velocity was measured using the
Grainer’s Thermal Dissipation Probe (TDP) method with TDP-30 (30-millimeter-long (0.1 inch)
needles) and TDP-80 (80-millimeter-long (0.3 inch)) sap flow sensors (Dynamax Inc., Houston,
TX). Sap flow sensors were installed in trees and shrubs following methods provided in
Dynamax (1997). Sensors were connected to a Campbell Scientific CR-1000 datalogger to
continuously record data at established intervals (Campbell Scientific, Logan, UT, USA).
Measurements of the difference in temperature (dT) between the heated upper probe (or needle)
and the unheated lower probe (needle) were acquired in 60-second intervals and averaged every
hour.
Depending on the DBH of the tree, between one and four sensors were installed into each tree so
that an average flow rate could be calculated (Dynamax1997). Specifically, one or two sensors
were installed on trees with DBH less than 24 centimeters (9 inches). Three sensors were
installed on trees with DBH 25–35 centimeters (9.8–13.8 inches), and four sensors were installed
on trees with DBH greater than 35 centimeters (13.8 inches). For trees with multiple sensors,
sensor placement was oriented to balance any potential effect of direct sunlight on sap flow (e.g.,
east and west orientation for trees with two sensors; north, southwest, and southeast orientation
for trees with three sensors; and northeast, southeast, southwest, and northwest orientation for
trees with four sensors).
4.6.2.4.2. Direct Stomatal Conductance Measurements
To measure the water use of herbaceous and small woody species, direct leaf-level stomatal
conductance measurements were made using a solid-state leaf porometer. Porometers measure
the resistance of water as it moves from the plant tissue. Steady-state leaf porometer units
(SC-1) were used to measure daily stomatal conductance for target species at FA-104 (Whiskers
Slough) and FA-128 (Slough 8A) during sample periods in June (early-season), July (mid-
season), and September (late-season). The September 2013 late-season sampling period was
truncated due to wet weather conditions and only a partial dataset is available for this period.
Sampling was conducted to document conductance by plant structural type (e.g., forb, sedge,
shrub, tree seedling, tree) and by species.
In order to scale-up leaf measurements to vegetation cover type, or functional group scale, Leaf
Area Index (LAI) was measured in four different canopy cover types within FA-104 (Whiskers
Slough) and FA-128 (Slough 8A). LAI, a dimensionless quantity, is the leaf area (upper side
only) per unit area of soil below it. It is expressed as square meter leaf area per square meter
ground area. The active LAI is the index of the leaf area that actively contributes to the surface
heat and vapor transfer and generally corresponds with the upper, sunlit portion of a dense
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 26 February 2014 Draft
canopy. LAI plots were set up to represent different vegetation cover types. LAI measurements
were taken within three Focus Areas: FA-104 (Whiskers Slough), FA-115 (Slough 6A), and
FA-128 (Slough 8A).
4.6.3. Riparian Plant-Frequency Response Curves
Floodplain vegetation−GW/SW regime functional groups are assemblages of plants that have
established and developed under similar GW/SW hydrologic regimes. For the Riparian IFS,
metrics will be developed for quantitatively describing the relationship between dominant
floodplain plant communities and the GW/SW hydroregime. Probabilistic response curves will
be developed for select plant species and sampled riparian plant community types using
techniques described in Rains et al. (2004) and Henszey et al. (2004). The results of the
individual plant species, and plant community type, response curve analyses will be used, along
with plant species rooting depth measurement characterizations, to develop floodplain
vegetation-GW/SW regime functional groups (Merritt et al. 2010; Rains et al. 2004).
Riparian plant-frequency response curves to water level gradients will be fit using non-linear
models as described in Henszey et al. (2004). The non-linear models will be used with both
individual species and plant community type data. As recommended by the FERC in the April 1
SPD, water-level summary statistics will be tested for best fit. Seasonal GW/SW hydroregime
patterns will be measured using riparian groundwater wells and surface water level recorders as
described in the Groundwater Study (see ISR Section 7.5). Riparian vegetation will be sampled
at each groundwater wellhead using methods described in the Riparian Vegetation Study (see
ISR Study 11.6). A number of surface water and groundwater pattern summary statistics will be
evaluated to assess linkages of surface water and groundwater levels, and regimes, to plant
frequency. Water level regime summary statistics will include, at a minimum (1) growing
season 10 percent cumulative frequency water level, and (2) growing season 7-day moving
average high water. Other, as yet to be determined, water level regime summary statistics will
also be evaluated in the analysis. Non-linear models will be fit through the data to quantify the
linkage between GW/SW hydroregime and plant frequency (Henszey et al. 2004). The analyses
will result in multiple models each describing the frequency with which a given plant species or
community type occurs primarily as a function of estimated groundwater and surface water
statistics (e.g., mean depth during growing season, growing season 7-day moving average high
water level). Therefore, an iterative statistical best-fit analysis will be conducted to create plant
frequency response curve models. The Riparian IFS team conferred at two riparian technical
meetings with members of the TWG in Q2 2013 concerning technical aspects of the riparian
plant frequency response curve analysis. The Riparian IFS team will seek further input from
interested TWG members concerning preliminary aspects of plant frequency response curve
model analysis in 2014.
4.6.4. Variances from Study Plan
No variances from the methods described in this component of the Study Plan occurred in the
2013 study season. Methods were refined from the RSP to the ISR as described in Section 4.6.2
above.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 27 February 2014 Draft
4.7. Floodplain Vegetation Study Synthesis, Focus Area to Riparian
Process Domain Model Scaling and Project Operations Effects
Modeling (hereafter, Riparian Vegetation Modeling Synthesis
and Project Area Scaling)
The results of floodplain vegetation and soils mapping, forest succession models, seed dispersal
study, seedling establishment studies, ice processes study, floodplain erosion and sediment
transport study, and groundwater and surface water interaction study will be integrated into a
conceptual ecological model of Susitna River floodplain vegetation and physical processes,
including flow, sediment, and ice process regimes. The results of these studies will be used to
develop a dynamic floodplain vegetation model for simulating floodplain vegetation response to
Project operation modification of the natural flow, sediment, and ice process regimes (Franz and
Bazzaz 1977; Benjankar et al. 2011; Springer et al. 1999).
Study objectives, methods, and expected results are summarized in Table 4.7-1.
Study objectives are to:
1. Develop conceptual ecological models of Susitna River floodplain vegetation
establishment and recruitment based on synthesis of Riparian Vegetation Study and
Riparian IFS results.
2. Scale-up results of Focus Area floodplain vegetation and physical process modeling
results to riparian process domains.
3. Develop a dynamic, spatially-explicit floodplain vegetation model for simulating
floodplain vegetation response to Project operation modification of the natural flow,
sediment, and ice process regimes.
4. Develop spatially-explicit maps of modeled Project operations effects throughout the
study area.
5. Provide guidance to environmental analysis of Project operations.
4.7.1. Methods
AEA is implementing the methods as described in the Study Plan with no variances.
The results of the Focus Area modeling will be scaled-up to the riparian process domains using
spatially-explicit GIS-based models (Benjankar et al. 2011; Chacon-Moreno et al. 2007). The
goal is to model both natural riparian flow-response functional groups and natural Susitna River
physical process regimes to measure and map Project operational impacts to floodplain
vegetation and riparian ecosystem processes throughout the study area. Recent developments in
GIS, LiDAR-driven digital terrain models (DEMs), and geo-spatial analytical tools (ARCMAP,
ESRI) have provided modelers the capacity to use the results of reach-scale analyses to scale-up
to larger geospatially defined areas or domains (Benjankar et al. 2011; Chacon-Moreno et al.
2007). Modeling riparian vegetation response, over a 185-mile Susitna River valley, to
alterations of natural flow regimes, is inherently a geospatial analytical problem. Current state-
of-the-art and science practice will be utilized to integrate modeling of physical processes (HEC-
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 28 February 2014 Draft
RAS, MODFLOW), and riparian vegetation-flow response functional groups with GIS
geospatial analysis and display (ARCMAP, HEC-GEORAS).
The objectives of the Focus Area scaling model are as follows:
1. Scale-up Focus Area modeling results to riparian process domains.
2. Assess potential impacts of Project operational flows on downriver floodplain plant
communities and ecosystem processes.
3. Provide guidance to environmental analysis of Project operations.
4.7.2. Variances from Study Plan
No variances from the methods described in this component of the Study Plan occurred in the
2013 study season.
5. RESULTS
5.1. Literature Review of Dam Effects on Downstream Vegetation
The Riparian IFS dam effects literature review on riparian vegetation will be combined with the
Fluvial Geomorphology Modeling Study dam effects literature review. Considering that fluvial
geomorphology and floodplain riparian ecology processes are interrelated, this coordinated effort
will more fully serve the Project than would two uncoordinated reviews. The critical review will
include an annotated, searchable bibliography with annotations of more than 100 references of
riparian floodplain effects of hydroregulation. Information describing the “state-of-the-science”
for floodplain effects of hydroregulation will be synthesized. This combined Fluvial
Geomorphology Modeling and Riparian IFS critical literature review paper and annotated
bibliography will be submitted in a Technical Memorandum in 2014.
5.2. Focus Area Selection−Riparian Process Domain Delineation
The results for the Middle River Segment delineation of riparian process domains paralleled the
geomorphic reach classification conducted by the Fluvial Geomorphology Modeling team. The
Middle River Segment delineation resulted in four representative Middle River Segment clusters
or “riparian process domains.” The Lower River Segment cluster analysis was less conclusive,
and it was decided not to use the cluster analysis at this stage for the 2013 riparian vegetation
sampling approach until further analysis could be conducted in the next study year. For the 2013
Lower River Segment vegetation sampling strategy, it was decided that the Riparian IFS would
use the existing five Geomorphic Reach Classifications provided by the Fluvial Geomorphology
Modeling team (Tetra Tech 2013).
Within the four Middle River Segment riparian process domains, eight Focus Areas were
identified and selected for intensive surveys of physical process, vegetation sampling [see
Riparian Botanical Survey (ISR Study 11.6, Section 4) for vegetation statistical sampling
protocols], and riparian floodplain interaction modeling. The Focus Areas were those considered
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 29 February 2014 Draft
most representative of the riparian process domains in terms of vegetation structure and
abundance, and channel/floodplain characteristics (channel planform, channel slope, channel
confinement). Process domain variability was assessed in terms of vegetation composition,
abundance, and structure within the selected Focus Areas relative to the associated riparian
process domain (Table 5.2-1, Table 5.2-2, and Table 5.2-3). To capture variability in floodplain
vegetation types, and geomorphic terrains within each riparian process domain not found within
the Focus Areas, satellite study sites have been surveyed outside Focus Areas using the ITU
riparian vegetation sampling protocols detailed in the Riparian Vegetation ISR (ISR Study 11.6,
Section 4).
Of the potential riparian Focus Areas, two were located within the moderately confined domain,
RPD-1, between the proposed dam site and Devils Canyon, and have narrow floodplains. Seven
of the potential Focus Areas were located within the moderately confined domain, RPD-3, which
extends downstream from Devils Canyon to the Transition Domain at FA-104 (Whiskers
Slough) and have varying floodplain widths. One Focus Area is located in the short Transition
domain, RPD-4, extending from the downstream end of the moderately confined process domain
to Three Rivers Confluence. Distribution and abundance of vegetation types within each Focus
Area were then compared to distribution and abundance of vegetation types across each riparian
process domain (Table 5.2-1, Table 5.2-2, and Table 5.2-3). Overall, the analysis demonstrated
that the vegetation types and abundance found within the eight Focus Areas provide a good
representation of the types and relative abundance of vegetation found within the respective
riparian process domains. As a result, these eight Focus Areas were given further consideration
by the riparian study team.
The riparian technical team, which included representatives from USFWS and other agencies,
met to discuss riparian vegetation classification and mapping and how the results of these studies
would be used to inform selection of representative Focus Areas as well as the degree to which
these FAs were representative of each riparian process vegetation types (February 21, 2013).
During the meeting, each of eight Focus Areas were reviewed and five were selected for detailed
study. Three not selected—FA-184 (Watana Dam), FA-171 (Stephan Lake Simple), and FA-144
(Side Channel 21)—were found to be lacking in one or more of the following characteristics:
representative floodplain vegetation type, floodplain terrain complexity, or wetland complexity
(see Table 5.2-4).
During the discussion, USFWS and NOAA representatives raised concerns regarding the
adequacy of the riparian FAs in representing the herbaceous vegetation types along the Middle
River. In response to these concerns, AEA conducted an additional analysis of the Middle River
herbaceous plant community types. The results were used (1) to determine how well the selected
FAs represented herbaceous vegetation within each RPD, and (2) to select additional areas
outside the FAs (“satellite areas”) in which to sample herbaceous vegetation, thus increasing
sample plot number for herbaceous vegetation in RPDs where the selected FAs may under-
represent complete RPD vegetation types. The conclusion of the analysis states:
“In areas of RPD-3 covered by ITU mapping, the low coverage of herbaceous vegetation types
in several of the FAs suggests that FA-138 (Gold Creek) be included as a riparian focus area in
RPD-3. Additionally, several satellite areas where herbaceous vegetation is abundant, including
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 30 February 2014 Draft
between PRM 112–113, 125–127, and 132–133, will be incorporated into the 2013 sampling
scheme.”
AEA prepared a technical brief summarizing the analysis, results, and conclusions (see Appendix
A). Further analysis of 2013 field results will be conducted and additional herbaceous satellite
areas will be selected for ITU sampling in the next study year. The final list of Focus Areas for
Riparian IFS investigations is provided in Table 5.2-5 and depicted in Figure 5.2-1. The selected
Focus Areas will be reviewed in the next study year using field data collected in 2013.
Data developed in support of the ISR is available for download at
http://gis.suhydro.org/reports/isr. This data is provided in the file titled
ISR_8_6_RIFS_ProcessDomain.shp.
5.3. Seed Dispersal and Seedling Establishment
5.3.1. Seed Dispersal
Seed release study sites were established at four sites in the Lower and Middle River Segments
(Figure 5.3-1): PRM 47 (Deshka Landing), PRM 88 (Parks Highway Bridge), PRM 102
(Talkeetna), and PRM 142 (Indian River) (Table 5.3-1, Figure 5.3-2, Figure 5.3-3, Figure 5.3-4,
Figure 5.3-5). Catkins releasing seed from 6 female balsam poplar (Populus balsamifera) trees
and 6 to 12 female willow (Salix spp.) shrubs were counted weekly at each seed release study
site. Trees and shrubs were selected and counts were initiated on June 6, 7, and 8, 2013. Weekly
counts continued throughout June and July. Weekly site visits were stopped when catkin counts
remained stable for several weeks following peak catkin count. The final counts were completed
on July 29 and 30, 2013. In total, eight counts were made at the PRM 47 and PRM 88 seed
release study sites, and nine counts were made at PRM 142 and PRM 102 seed release study
sites.
Continuous, 15-minute interval temperature records from January to July 2013 for the PRM 102
and PRM 142 sites were obtained from AEA weather stations. HOBO temperature sensors were
installed to determine local temperatures on June 6 and June 8, 2013 at PRM 88 and PRM 47
sites, respectively. Because these HOBO sensors were installed midway through the year, June
and July 2013 temperatures were used directly from the HOBO output and January to June 2013
temperatures at these sites were estimated using linear regression developed from correlation
with the Talkeetna airport (National Climate Data Center, NOAA) mid-point temperatures
((Max-Min)/2). The prediction models were: PRM 47 temperature=1.2+0.94*Airport temperature
PRM 88 temperature=2.4+0.83*Airport temperature
The temperatures used for each site are displayed in Figure 5.3-6. HOBO sensors were removed
on October 6, 2013.
A preliminary degree-day model following the methods of Stella et al. (2006) was developed
using 2013 seed release counts and the temperature records obtained from each site and the
Talkeetna Airport. The duration of the peak seed release window, bounded by the 20th and 80th
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 31 February 2014 Draft
cumulative quantiles (DY20 to DY80), was determined for poplar and willows at each site where
sufficient data were collected in 2013 (Table 5.3-2). Plants were removed from analysis if they
had fewer than 10 catkins or if the first count in June contained more than 20 percent of catkins
releasing seed. Additionally, sites with fewer than three plants of a given species with estimable
DY20 were not included in the summary table. Continuous, 15-minute interval Susitna River
discharge data from the USGS discharge gage at Gold Creek was compared to peak seed release.
Peak discharge appeared to occur from June 1 to 2, 2013. Depending on site, the peak period of
seed release for poplar began 17 to 20 days following peak discharge (Figure 5.3-7 and Figure
5.3-8).
In addition to the degree-day threshold related to the initiation of seed release (DY20), the base
temperature representing the lower thermal limit to annual plant development was predicted
using 2013 data. The accumulated degree-days for 26 integer base values from -5 to 20°C up to
the site mean DY20 were estimated for each site (i.e., a 4 x 26 matrix of degree-days). The
average degree-day trigger (across the four sites) for each potential base temperature was then
used to “model” a DY20 for each site (i.e., a 4 x 26 matrix of predicted DY20). These site-
specific predictions were compared to the observed DY20 for each plant at that site, using the
relative mean-squared error (RMSE). The base temperature that resulted in the lowest RMSE
was 6°C (42.8°F). In other words, the estimated DY20 based on degree-days accumulated above
42.8°F was on average the closest to observed DY20 across plants. Thus, 6°C (42.8°F) is the
estimated optimal base temperature. The average degree-days at or above the optimal base
temperature accumulated at DY20 was used as the estimated “trigger” for seed release. For
poplar, the estimated trigger (DY20) is 260 degree-days. Using the same optimal base
temperature, DY80 corresponds to 345 degree-days over 42.8°F. Willows were not used for
modeling because there were not enough data for a single species and variance in seed release
timing between willow species is high. The findings described are preliminary because they are
based on only a single year of data. The seed release study will be repeated in a second study
year, and models will be recalculated and revised as needed.
Data developed in support of the ISR is available for download at
http://gis.suhydro.org/reports/isr. This data is provided in the file titled
ISR_8_6_IFS_Seed_Release.xls.
5.3.2. Seedling Establishment and Recruitment
5.3.2.1. First Year (0+) Balsam Poplar and Willow Seedling Establishment
During reconnaissance surveys of lateral margins in Focus Areas 104 (Whiskers Slough), 113
(Oxbow 1), 128 (Slough 8A), 138 (Gold Creek), and 144 (Side Channel 21), approximately 30
polygons with dense populations of first year seedlings were mapped. Following this
reconnaissance mapping effort, transects were distributed across Focus Areas and across a range
of geomorphic positions (e.g., main channel, side channel, slough, island head, island tail) as
described in Table 5.3-3. A total of 35 first year (0+) balsam poplar and willow seedling
establishment transects were documented in 17 of the mapped seedling polygons between July
30 and August 7, 2013 (Figure 5.3-9, Figure 5.3-10, Figure 5.3-11, Figure 5.3-12, Figure 5.3-13).
Per the Study Plan, a second sampling effort was completed for the seedling establishment study
between September 7 and September 11, 2013.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 32 February 2014 Draft
Transects were oriented perpendicular to the edge of water and extended upslope to where full
canopy cover by trees or shrubs began. Transects ranged from 6.73 meters (22.1 ft) to 49.81
meters (163.4 ft) in length. Plots (0.25 meter x 0.25 meter; 0.8 ft x 0.8 ft) were placed at 1 meter
(3.3 ft) intervals along each transect for a total of 824 plots distributed across the five Focus
Areas. A total of 41,553 poplar and 7,643 willow seedlings were counted in the plots in the first
survey effort (July 29–August 8). When seedlings in these plots were counted again for the
second survey (September 7–11, 2013), only 11,498 poplar seedlings (28 percent) and 4,882
willow seedlings (64 percent) were counted. Survival rate between sites was highly variable
with poplar seedling survival along individual transects ranging from 0.5 to 65 percent and
willow seedling survival ranging from 0 to 90 percent. Seedling counts observed in each transect
are grouped by Focus Area (Figure 5.3-14 and Figure 5.3-15) and by geomorphic position
(Figure 5.3-16 and Figure 5.3-17) to illustrate survival patterns during Year 1 of the seedling
establishment study.
Flows in June and July 2013 were moderate following the spring peak discharge shortly after
break-up. The first sample event in late July and early August occurred during moderate flows.
A peak flow event occurred between the first and second sampling periods with maximum
discharge at Gold Creek of 49,100 cfs (Figure 5.3-18).
Fifteen wells were established at eight seedling establishment sites between August 5 and 9,
2013. Paired wells (one well at the approximate mid-point of the seedling plot transect and one
well near the upper end of the transect) were installed at each well transect, except FA-138 (Gold
Creek). Only a single well was installed at FA-138 (Gold Creek) because intensive groundwater
monitoring was occurring in association with the Groundwater ISR Study 7.5 in the vicinity of
this site. Water levels were measured in each well at least three times in August and September.
Seedling rooting depths were measured for ten randomly selected first year poplar seedlings
rooted along Transect 1 in FA-104 (Whiskers Slough) on September 26 and 27. Seedlings were
randomly selected from three distinct zones (0-6 meters, 6-12 meters, and 12-18 meters, with
0 m starting closest to flowing water) along the transect. Figure 5.3-19 presents rooting depths
relative to shoot lengths observed for these 30 seedlings plotted by collection zone.
A total of 27 seedling composite samples were collected for isotope analysis along transects at
FA-104 (Whiskers Slough), FA-113 (Slough 6A), and FA-128 (Slough 8A), to assess
predominant water source. Seedling transects were labeled as the Focus Area number with the
seedling transect number (STR) within the Focus Area. Representative seedling transects
selected for isotope sample collection were FA-104 STR1, FA-113 STR2, and FA-128 STR1.
Each seedling establishment transect sampled was divided into thirds and three composite
samples were collected at each distance from surface water. Composite samples did not
discriminate against species and were made up of hundreds of individual samples. Samples were
predominantly made up of feltleaf willow (S. alaxensis) and poplar (P. balsamifera) seedlings.
Attempts to sample groundwater were unsuccessful due to cold temperatures in September,
freezing the water in the shallow wells. These samples will be processed by a stable isotope
laboratory.
Figure 5.3-20, Figure 5.3-21, and Figure 5.3-22 provide the topographic survey along transects,
depth to cobble, seedling density (in seedlings per square meter), and surface substrate estimates
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 33 February 2014 Draft
for two representative seedling establishment transects. Ocular estimates of surface substrate
(sand/silt versus gravel/cobble) were conducted at each plot at each sampling period. In
addition, sediment samples were collected at plots where seedlings survived to the September
sample period. Sediment samples are being analyzed for sand, silt, and clay fractions with
standard hydrometer methodology. These results will be available in 2014. Additional statistical
analyses will be conducted following surveys in the next study year to assess relative importance
of environmental factors on seedling survival.
Data developed in support of the ISR is available for download at
http://gis.suhydro.org/reports/isr. This data is provided in the file titled
ISR_8_6_RIFS_StudyTransectsSE.shp.
5.3.2.2. Clonal Balsam Poplar and Willow Establishment and Recruitment
During surveys for the first year (0+) balsam poplar and willow seedling establishment study
completed in Q2 and Q3 2013, reconnaissance surveys were conducted along channel lateral
margins to assess patterns of clonal balsam poplar and willow establishment and recruitment.
Clonal populations will be surveyed formally in the next study year with excavation of
representative specimens and measurements of depth of burial, and height above floodplain
surface.
5.3.2.3. White Spruce and Paper Birch Establishment and Recruitment
In 2013, to characterize white spruce establishment patterns, 12 8-meter-wide (26.25 feet wide)
belt transects were surveyed covering approximately 3.5 hectares (8.7 acres) on seven mid-
channel islands in the Middle River Segment. Two transects were surveyed at each of five
islands and a single transect was surveyed on two islands (Table 5.3-4; Figure 5.3-23, Figure 5.3-
24, Figure 5.3-25, Figure 5.3-26, and Figure 5.3-27). Surveys were designed to characterize
spruce population density, size and distribution by age class (i.e., seedlings, trees, and snags).
Seedling spruce were considered to be all individuals with heights less than 1.4 meters (4.5 ft)
and spruce trees were considered to have heights greater than or equal to 1.4 meters (4.5 ft).
This height was chosen as the cutoff because it is the height at which DBH can be measured, and
a relationship may be developed between age and DBH. Spruce height estimates ranged from
0.1 to 25 meters (0.32 to 82 ft). Across all islands, a total of 426 spruce were recorded consisting
of 226 seedling spruce and 200 tree and snag spruce. For the 200 spruce trees with heights
greater than 1.4 meters (4.5 ft), DBH ranged from less than 1 cm to 41.5 cm (0.4 to 16.3 inches).
Figure 5.3-28, Figure 5.3-29, and Figure 5.3-30 provide seedlings, tree, and snag spruce counts
observed along each transect. Figure 5.3-31 and Figure 5.3-32 illustrate the distribution of
seedling and spruce trees relative to position on the island.
On each island, between 5 and 12 spruce were randomly selected and sampled to determine age,
height, DBH, depth of burial above the root collar and depth to cobble. The core samples are
currently being processed using standard dendrochronology methods (Fritts 1976) described in
Section 4.5.1 to determine age.
Sediment cores were assessed at 5 to 10 locations per island to determine the number and depth
of layers with increased organic matter content in upper 30 cm (11.8 inches) of the soil profile
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 34 February 2014 Draft
(Table 5.3-5; Figure 5.3-33). Alternating organic to mineral layers may be used to indicate
flood-deposited sediment. The number of organic layers in the upper 30 cm (11.8 inches) ranged
from one to eight with depth to cobble ranging from 28 cm (11.0 inches) to greater than 123 cm
(48.4 inches) (Table 5.3-5). Figure 5.3-34 presents mean number of organic layers and mean
depth to cobble observed at each island.
5.4. River Ice Effects on Floodplain Vegetation
Aerial mapping during ice break-up included observations of an area on islands located between
PRM 134 and 135 in which ice-dam rafting of ice sheets had caused a high magnitude of
disturbance of floodplain forest stands. The floodplain vegetation on an island in this area was
subsequently sampled using standard dendrochronology plot and belt transect methods to
document the extent and magnitude of floodplain vegetation disturbance (see Section 4.3.2.1 for
methods).
A survey of tree ice-scars was conducted from PRM 102.2 to PRM 145.8 between September 15
and 29, 2013. River right and river left were surveyed from a jet boat using a Trimble
GeoExplorer XT interfaced with a TruPulse 360 Laser to capture GPS point offsets. At 0.2-mile
intervals, ice-scar survey points were established along river right and river left. At each ice-scar
survey point, a GPS point and photographs were taken, the height of the floodplain surface above
water level was measured, and the height of an ice-scar on one representative tree was measured,
if any ice-scars were present. Occasionally, the view of an entire ice-scar was obstructed, or
recent knock down of young vegetation was visible, but elevations could not be measured from
the boat. In these cases ice damage was noted but not measured. Between each location, the
number of ice-scarred trees that could be viewed from the river was counted. A total of 222 ice-
scarred trees, 190 locations with no visible ice-scars, and 29 locations with signs of ice damage
that were not measurable were surveyed. Thus, 441 locations were surveyed in total.
Data developed in support of the ISR is available for download at
http://gis.suhydro.org/reports/isr. This data is provided in the files titled
ISR_8_6_IFS_IceScarData.xls and ISR_8_6_RIFS_IceScarSurvey.shp.
In addition to the systematic 0.2-mile survey locations along each bank, 48 ice-scarred trees were
sampled for dendrochronologic analysis. Intensive ice-scar wedge sampling occurred at three
Focus Areas: 13 samples were collected at FA-104 (Whiskers Slough), 20 from FA-115 (Slough
6A), and 15 from FA-128 (Slough 8A). Each sample consisted of a wedge that was removed
from the tree with a 16-inch chainsaw (Figure 4.4-4). The wedge included the ice-scarred
section and subsequent growth adjacent to the scar. At each sampled tree, GPS coordinates,
photographs, floodplain height above water, ice-scar height above floodplain, and tree diameter
at breast height were also measured. Dendrochronologic analyses will be performed on each
wedge in Q4 2013 through early 2014 to date each ice-scarring event (Fritts 1976; Stoffel and
Bollschweiler 2008).
The top of measured ice-scars ranged in height from 0.2 to 4.3 meters (0.66 to 14.1 ft) above the
floodplain, and averaged 1.8 ± 0.7 meters (5.8 ± 2.4 ft) (Figure 5.4-1). Data from ice-scar wedge
sampling in the three Focus Areas showed similar average ice-scar heights above the floodplain
at three Focus Areas (Figure 5.4-2). Values for the height of the floodplain and ice-scar above
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 35 February 2014 Draft
water are not reported because measurements were taken on different days with varying river
stage. Height above water level will be standardized when stage-discharge models are available.
Preliminary mapping of floodplains affected by ice processes was begun by importing point data
into ArcGIS 10.1. Figure 5.4-3, Figure 5.4-4, Figure 5.4-5 show ice-scar mapping along
representative reaches. Preliminary analysis is revealing areas where ice-scars were more
frequent (e.g., Figure 5.4-3) and areas where ice-scars were less frequent (e.g., Figure 5.4-4).
Figure 5.4-5 shows a representative reach along FA-104 (Whiskers Slough) where ice-scar
sampling was completed along with ice-scar surveys.
5.5. Floodplain Stratigraphy and Floodplain Development
Sediment cores were collected during 2013 at 13 locations in the Middle River Segment,
including 5 cores at FA-104 (Whiskers Slough) and 8 cores at FA-115 (Slough 6A) (Figure 5.5-1
and Figure 5.5-2). At both FA-104 (Whiskers Slough) and FA-115 (Slough 6A), sediment
sample sites were located at ITU plot floodplain locations along transects perpendicular to the
Susitna River. These samples will be analyzed for 210Pb and 137Cs isotopes.
Tree and shrub distribution and abundance were assessed by recording data at 80 ITU and mid-
channel island plots in 2013. More than 450 cores and cookies representing approximately 250
trees and shrubs were collected in Q3 2012 and Q2 and Q3 2013. These cores are being
analyzed in Q4 2013 and early 2014, so tree age data are not available for inclusion in this ISR.
Existing tree and shrub plot data are summarized by preliminary Viereck IV plant community
type as mapped by Riparian Vegetation (Study 11.6) in 2012 (Table 5.5-1). Plot locations are
shown in Figure 5.3-23, Figure 5.3-24, Figure 5.3-25, Figure 5.3-26, Figure 5.3-27, and Figure
5.5-1 and Figure 5.5-2).
Data developed in support of the ISR is available for download at
http://gis.suhydro.org/reports/isr. This data is provided in the files titled
ISR_8_6_RIFS_StudySites.shp and ISR_8_6_RIFS_StudyTransects.shp.
5.6. Riparian GW/SW Hydroregime
5.6.1. Stable Isotope Analyses
Water isotope samples were collected during Q2 and Q3 2013 to characterize seasonal riparian
plant species water acquisition sources. Sampling was focused on plant water samples (xylem
tissue), soil water samples, and surface/groundwater samples, at FA-104 (Whiskers Slough) and
FA-128 (Slough 8A). Sampling occurred three times during the growing season (June, July, and
September). All samples were collected along the GW/SW transects (Table 5.6-1; Figure 5.6-1,
Figure 5.6-2, and Figure 5.6-3).
A total of 659 plant samples were collected in the summer of 2013 for isotopic analysis: 245
herbaceous samples, 206 shrub samples, and 208 tree samples. Sampling procedures focused on
dominant floodplain plant species: A. viridus ssp. crispa, A. incana ssp. tenuifolia, B. papyrifera,
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 36 February 2014 Draft
P. glauca, P. balsamifera, M. struthiopteris, V. edule, C. canadensis, and a suite of unidentified
Salix spp. (Figure 5.6-4; Table 5.6-1).
Soil cores were taken proximal to plant sampling locations to collect soil water samples at
specific depths. A total of 545 soil samples were collected in 2013 (Table 5.6-2). Water samples
were taken in conjunction with plant and soil samples. A total of 100 water samples were taken,
with the majority being precipitation samples. Precipitation samples were collected throughout
the growing season. Samples were collected along the GW/SW transects at every surface water
source intersecting the transects (Table 5.6-3; Figure 5.6-1, Figure 5.6-2, and Figure 5.6-3). At
least two 20-ml vials of water were taken at each source. Groundwater samples were collected
in September following well installations.
All water samples will be extracted and analyzed by a stable isotope laboratory. Analysis and
modeling will occur during the next study year.
5.6.2. Rooting Depth
Soil cores were taken in conjunction with soil isotope samples. During the 2013 growing season,
335 samples were collected, washed and sieved, and sorted. Currently, roots are frozen until
they can be properly dried and weighed.
5.6.3. Plant Transpiration
During the summer months of 2013, TDP sensors were installed at 21 trees at FA-104 (Whiskers
Slough) and 27 trees at FA-128 (Slough 8A) (Figure 5.6-1 and Figure 5.6-3). Sap flow sensors
were first installed in mid-July at station ESGFA104-4 (Figure 5.6-1). Sap flow sensor
installation was completed at FA-104 (Whiskers Slough) in late July 2013. Installation of sap
flow sensors at FA-128 (Slough 8A) was completed in September 2013 (Figure 5.6-3). All
sensors recorded data until October 10, 2013, except a few P. glauca trees at FA-104 (Whiskers
Slough). At these select P. glauca trees, sampling continued through the end of October to
ascertain the seasonal extent of transpiration.
A total of 98 sap flow sensors were installed into 38 trees/shrubs during Q2 and Q3 2013. These
trees/shrubs included seven A. incana ssp. tenuifolia, eight B. papyrifera, ten P. glauca, seven
P. balsamifera trees, and six unidentified Salix sp. (Table 5.6-4). All sap flow sensors were
installed at stations across the GW/SW transects, with four stations at FA-104 (Whiskers Slough)
and FA-128 (Slough 8A) (Figure 5.6-1 and Figure 5.6-3). Having multiple sites per transect
allowed for comparison of sap velocity between trees close to the Susitna River (ESGFA104-8)
and trees located far up into the floodplain (ESGFA104-4; Figure 5.6-5).
Individual trees and shrubs across the range of stem diameters present across the Middle River
floodplain forests were selected for sap flow measurements. Average DBH for sample trees are
as follows: A. tenuifolia (10.57 cm±4.95), B. papyrifera (27.48 cm±6.98), P. glauca (33.34
cm±8.29), P. balsamifera (92.59 cm±36.99), and unidentified Salix species (10.24 cm±5.85).
Difference in temperature measured (dTM) and sap velocity are being recorded to dataloggers.
Sap velocity reduced dramatically after leaves dropped in the fall, effectively ending seasonal
transpiration (Figure 5.6-6). Preliminary analysis results comparing randomly selected sap
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 37 February 2014 Draft
velocity data with Vapor Pressure Deficit (VPD) are presented in Figure 5.6-5. VPD is the
difference of water vapor concentration inside and outside the leaf; it is a good indicator for
potential transpiration. During higher VPD days, there is a large gradient from outside the leaf to
inside the leaf initiating water vapor movement, meaning higher potential for transpiration.
When day-to-day VPD, measured at FA-104 (Whiskers Slough) (Figure 5.6-5 (c)) is compared
to sap flow velocity measured at FA-104 (Whiskers Slough) (Figure 5.6-5 (a) and (b)), the trends
are very similar.
Stomatal conductance was measured to quantify transpiration of herbaceous species and small
woody shrubs. Stomatal conductance measurements were collected at FA-104 (Whiskers
Slough), FA-115 (Slough 6A), and FA-128 (Slough 8A) during Q2 and Q3 2013. The bulk of
conductance measurements were made in June and July at FA-104 (Whiskers Slough) and
FA-128 (Slough 8A) (Table 5.6-5 and Table 5.6-6). Additional measurements were made at FA-
115 (Slough 6A) in July to verify if sampling methods would work in Carex spp. meadows.
Throughout the summer, a total of 3,602 individual stomatal conductance measurements were
made. This included measurements from 1,747 herbaceous plants (11 species), 1,771 shrubs (11
species), and 79 trees (3 species). The average daily conductance of the entire dataset is 262.9
mmol m-2s-1±143.7. Both the maximum and minimum stomatal conductance were recorded on
June 11, 2013. The minimum conductance was 12.9 mmol m-2s-1, recorded from Trientalis
europaea at 9:46 am. The maximum stomatal conductance measured was 965.8 mmol m-2s-1,
recorded from Salix alaxensis at 1:26 pm. Distribution of stomatal conductance values from
several species is provided in box plots (Figure 5.6-7 and Figure 5.6-8). Late season (mid-
September 2013) conductance measurements were cut short due to wet weather accompanied by
leaf senescence.
Leaf Area Index (LAI) measurements were made along the GW/SW transects at FA-104
(Whiskers Slough), FA-115 (Slough 6A), and FA-128 (Slough 8A). LAI transects were chosen
in areas that represented distinct plant community canopy cover types. Poplar sites were
exclusively dominated by P. balsamifera, spruce/ birch sites were dominated by a B. papyrifera
and P. glauca overstory canopy, and alder/willow sites were dominated Alnus and Salix species.
(Figure 5.6-1, Figure 5.6-2, Figure 5.6-3, and Figure 5.6-9). Throughout the summer a total of
597 sample points were recorded using a hand-held ceptometer.
Similar to seasonal isotope sampling and conductance measurements, LAI was measured three
times throughout the growing season in 2013. Measured LAI was greatest in July when all
leaves had fully emerged. The third sampling period took place in mid-September
(September 13 and 22). The majority of leaves had fallen by this sampling effort and LAI results
are shown as lower than in the first two sample periods.
Volumetric soil water content sensors were installed adjacent at FA-104 (Whiskers Slough) and
FA-128 (Slough 8A). The sensors were installed on August 16 and September 17, 2013 at
FA-104 (Whiskers Slough) and FA-128 (Slough 8A), respectively. Sensors were installed at
depths of 5, 10, 20, 50, 110, and 200 cm and at 5, 10, 25, 44, 65, and 85 cm at FA-104 (Whiskers
Slough) and FA-128 (Slough 8A), respectively. The depth to cobble layer was much shallower
at FA-128 (Slough 8A) than at FA-104 (Slough 6A) and thus sensors were only placed to a depth
of 85 cm. During the month of September, soil moisture at shallow depths responded rapidly to
precipitation (Figure 5.6-10). Soil moisture at intermediate depths (20 and 50 cm) showed
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 38 February 2014 Draft
delayed responses of a couple of days, while deeper depths (110 cm and 200 cm) remained
consistently saturated during the month of September (Figure 5.6-10).
Data developed in support of the ISR is available for download at
http://gis.suhydro.org/reports/isr. This data is provided in the files titled
ISR_8_6_RIFS_StudySites.shp and ISR_8_6_RIFS_StudyTransects.shp.
5.7. Floodplain Vegetation Modeling Synthesis and Project Scaling
The floodplain vegetation modeling approach was further developed as planned throughout 2013
based upon riparian IFS field results and refinement of Ice Processes (Study 7.6), FA-IFS (Study
8.5) and Fluvial Geomorphic Modeling (Study 6.6) efforts. Further, TWG input concerning
development of floodplain vegetation modeling and project scaling will be sought in 2014.
6. DISCUSSION
6.1. Literature Review of Dam Effects on Downstream Vegetation
While it was proposed in the Study Plan that the literature review would be a part of the ISR
submittal, it has become clear that the literature review and annotated bibliography will be more
suitable as a stand-alone technical memorandum. Producing the literature review in coordination
with the Fluvial Geomorphology Modeling Study (Study 6.6) will provide a more integrated and
user-friendly document than if two separate documents were developed. While this is a change
in format from what was proposed in the Study Plan, there are no impacts on meeting the
objectives of this study and thus it was not considered a variance. This review is scheduled to be
submitted in 2014. This study is meeting study objectives set forth in the FERC-approved Study
Plan.
6.2. Focus Area Selection−Riparian Process Domain Delineation
Focus Areas for the Riparian IFS studies (primary riparian study sites) were selected in 2013 per
methods described in Section 4. Riparian study site selection was further discussed in the Focus
Area Selection Technical Memorandum (R2 Resource Consultants 2013) and details presented at
Riparian Technical Meetings held in 2013 (April and June 2013). As stated in the Study Plan,
riparian process domain definition will be further refined as needed based upon 2013 field
surveys data. The floodplain Focus Area Selection – Riparian Process Domain Delineation will
integrate results from interrelated studies in the next study year. This study is meeting study
objectives set forth in the FERC-approved Study Plan.
6.3. Seed Dispersal and Seedling Establishment
During Q2-Q3 2013, the seed dispersal and seedling establishment study met objectives outlined
in the Study Plan. The seed release study completed weekly counts of open catkins releasing
seed for Populus balsamifera trees and Salix spp. shrubs at four locations in the Lower and
Middle River Segments. Local temperature data were collected at each study site and from the
Talkeetna Airport. Initial models were developed to correlate temperature at each of the seed
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 39 February 2014 Draft
dispersal study site with the Talkeetna Airport where long-term climate records are available.
Additional temperature data will be collected from local sensors in the next study year to
increase climate model accuracy. Susitna River discharge was obtained from the USGS Gold
Creek and Sunshine discharge stations with historic records dating to the 1950s. The 2013 data
provides preliminary degree-day modeling for Populus balsamifera, Salix alaxensis, Salix
barclayi, and Salix sitchensis. Models will be rerun and refined after a second year of data
collection. A recruitment box model for P. balsamifera and Salix spp. will be developed to
provide insight for decisions on operational flows that facilitate seedling establishment of these
Salicaceae riparian species.
For the seedling establishment study, transects were set up, marked, and seedling populations
were counted in each plot twice during the 2013 growing season to capture the long-term
bimodal summer discharge trend. A peak flow event occurred between the two sampling efforts.
As expected, in large part due to the late August peak flow, mortality occurred between the
August and September study efforts, and many of the seedlings were lost between the first and
second sampling efforts. Because only poplar and willow first-year (0+) seedlings were
documented along these seedling establishment transects, additional methods have been
developed to describe seedling recruitment patterns for other dominant woody species, white
spruce and paper birch and clonal recruitment patterns for poplar and willow. This study is
meeting study objectives set forth in the FERC-approved Study Plan.
6.4. River Ice Effects on Floodplain Vegetation
During Q3 2013, river ice and floodplain vegetation modeling study objectives were met through
tree ice-scar surveys and tree ice-scar dendrochronologic sampling. Ice-scar surveys were
completed along 33.6 miles of the Susitna River Middle River Segment, and samples were
collected for ice process dating in three Focus Areas. Mapping of survey data was initiated to
inform in development of the floodplain vegetation study for the next study year. During Q3
2013, interviews were tentatively set up with local residents to discuss historic ice dams;
however, weather conditions and unforeseen fieldwork needs prevented these meetings from
taking place. They will be rescheduled during the next study year. Access to certain reaches
along the river was limited due to low discharge during surveying at the end of September 2013.
As a result, ice-scar information for a few sections of the main channel (near PRM 127) and
along most side channels was not obtained in 2013. Additional surveys will be completed in the
next study year to increase coverage of the ice-scar dataset in the Middle River Segment. Select
reaches in the Lower River Segment will be surveyed in the next study year. This study is
meeting study objectives set forth in the FERC-approved Study Plan.
6.5. Floodplain Stratigraphy and Floodplain Development
Project objectives are being met for the Floodplain Stratigraphy and Floodplain Development
study effort. Thirteen soil core samples were collected for isotope analysis. Tree and shrub
distribution and abundance were quantified at 80 Riparian Vegetation (Study 11.6) ITU and
Riparian IFS mid-channel island plots. Tree cores were collected and are being analyzed to
determine age distribution at select locations in the floodplain. These 2013 results are being
analyzed in combination with the Riparian Vegetation (Study 11.6) to characterize plant
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 40 February 2014 Draft
communities along the floodplain and refine vegetation maps. This study is meeting study
objectives set forth in the FERC-approved Study Plan.
6.6. Riparian GW/SW Hydroregime
During 2013, objectives set in the Study Plan were met relative to collection of representative
water samples for plant water isotope sources determination. During this time period, over 1,200
total plant xylem samples, soil water, slough, main channel, rain, and groundwater samples were
collected. Through cryogenic distillation processes, water will be removed from samples and all
water isotope samples will be analyzed. Once results are received from the stable isotope lab,
samples will be compared through a mixing model (Dawson et al. 2002). Upon review of
isotope analyses results, adjustments to sample size for the next study year will be confirmed.
The study is progressing toward meeting objectives set in the Study Plan and technical team
meetings to collect the necessary data needed to build transpiration curves for MODFLOW
modeling. During 2013, all instrumentation infrastructure was successfully installed by the end
of Q3, allowing for full GW/SW interactions to be monitored during the next study year. All sap
flow arrays were installed and tested by the end of September as well as a total of eight stations
across the GW/SW transect, with four stations at FA-104 (Whiskers Slough) and four at FA-128
(Slough 8A). Figure 5.6-5 shows that data collected to date shows typical responses for
transpiration relative to meteorological drivers. All instrumentation infrastructure is in place for
a complete capture of sap flow during the next growing season.
Over 3,000 stomatal conductance measurements were made during Q2-Q3 of 2013. During the
2013 growing season, Riparian-IFS crews completed two successful sampling periods at FA-104
(Whiskers Slough) and FA-128 (Slough 8A). Late-season measurements were cut short due to
wet weather, which led to early senescence of leaves. Initial conductance modeling began in Q4
of 2013, but these results are not yet available for this ISR.
In addition to transpiration measurements, LAI was measured in a suite of community types, soil
moisture probes were installed at FA-104 (Whiskers Slough) and FA-128 (Slough 8A), and
weather stations were installed at FA-104 (Whiskers Slough), FA-115 (Slough 6A), and FA-128
(Slough 8A). LAI measurements will be incorporated into transpiration models. Three seasonal
measurements of LAI will be conducted at FA 115 (Slough 6A) in the next study year. Data
from meteorological weather stations covering three FAs across the Middle River will provide
data necessary for evapotranspiration (ET) models. This study is meeting study objectives set
forth in the FERC-approved Study Plan.
6.7. Floodplain Vegetation Modeling Synth esis and Project Scaling
A synthesis of all Riparian IFS study results, and results of supporting modeling studies, will
inform development of a conceptual ecological model of Susitna River floodplain vegetation and
physical processes. Riparian IFS and supporting studies include (1) floodplain vegetation and
soils mapping, forest succession models (Riparian Vegetation Study 11.6); (2) seed dispersal
study, seedling establishment studies, Ice Processes Study (Study 7.6); (3) floodplain erosion and
sediment transport study (Geomorphology Study 6.5); and (4) groundwater and surface water
interaction study (Groundwater Study 7.5). The approach to scaling of riparian Focus Area
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 41 February 2014 Draft
results to riparian process domain will be developed and reported in the USR. The conceptual
ecological model, and scaling approach, will form the framework for development of the
floodplain vegetation model for simulating floodplain vegetation response to Project operational
modification of the natural flow, sediment, and ice processes regimes to be conducted in the next
study year. This study is meeting study objectives set forth in the FERC-approved Study Plan.
7. COMPLETING THE STUDY
[As explained in the cover letter to this draft ISR, AEA’s plan for completing this study will be
included in the final ISR filed with FERC on June 3, 2014.]
8. LITERATURE CITED
Aalto, R., L. Maurice-Bourgoin, T. Dunne, D.R. Montgomery, C.A. Nittrouer, and J. Guyot.
2003. Episodic sediment accumulation on Amazonian flood plains influenced by El
Nino/Southern Oscillation. Nature 425: 493-497.
Aalto, R., J.W. Lauer, and W.E. Dietrich. 2008. Spatial and temporal dynamics of sediment
accumulation and exchange along Strickland River floodplains (Papua New Guinea) over
decadal-to-centennial timescales. Journal of Geophysical Research 113: 1-22.
AEA (Alaska Energy Authority). 2012. Revised Study Plan: Susitna-Watana Hydroelectric
Project FERC Project No. 14241. December 2012. Prepared for the Federal Energy
Regulatory Commission by the Alaska Energy Authority, Anchorage, Alaska.
http://www.susitna-watanahydro.org/study-plan.
Amlin, N.M. and S.B. Rood. 2002. Comparative tolerances of riparian willows and
cottonwoods to water-table decline. Wetlands 22: 338-346.
Baird, K.J. and T. Maddock. 2005. Simulating riparian evapotranspiration: a new methodology
and application for groundwater models. Journal of Hydrology 312: 176-190.
Benjankar, R., G. Egger, K. Jorde, P. Goodwin and N.F. Glenn. 2011. Dynamic floodplain
vegetation model development for the Kootenai River, USA. Journal of Environmental
Management 92: 3058-3070.
Braatne, J.H., S.B. Rood and P.E. Heilman. 1996. Life history, ecology, conservation of
riparian cottonwoods in North America. In: Biology of Populus and its Implications for
Management and Conservation (Eds. R.F. Stettler, H.D. Bradshaw, P.E. Heilman and
T.M. Hinckley), pp. 57-86. NRC Research Press, Ottawa.
Chacon-Moreno, E., J.K. Smith, A.K. Skidmore, H.H.T. Prins and A.G. Toxopeus. 2007.
Modeling spatial patterns of plant distribution as a consequence of hydrological dynamic
processes in a Venezuelan flooding savanna. Ecottopicos 20: 55-73.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 42 February 2014 Draft
Cooper, D.J., D.R. D’Amico, and M.L. Scott. 2003. Physiological and morphological response
patterns of Populus deltoides to alluvial groundwater pumping. Environmental
Management 31(2): 215-226.
Cooper, D.J., D.M. Merritt, D.C. Anderson and R.A. Chimner. 1999. Factors controlling the
establishment of Fremont cottonwood seedlings on the upper Green River, USA.
Regulated Rivers: Research & Management 15: 419-440.
Dawson, T.E. and J.R. Ehleringer. 1991. Streamside trees that do not use streamside water.
Nature 350: 335-337.
Dawson, T.E., J.R. Ehleringer, A.E. Hall, and G.D. Farquhar. 1993. Water sources of plants as
determined from xylem-water isotopic composition: perspectives on plant competition,
distribution, and water relations. In: Stable isotopes and plant carbon-water relations.
(pp. 465-496). Academic Press Inc.
Dawson, T.E., S. Mambelli, A.H. Plamboeck, P.H. Templer, and K.P. Tu. 2002. Stable isotopes
in plant ecology. Annual Review of Ecology and Systematics, 507-559.
Dynamax. 1997. Thermal Dissipation Probe User Manual. Houston, TX. 12 pp.
Elzinga, C.L., D.W. Salzer, and J.W. Willoughby. 1998. Measuring and Monitoring Plant
Populations. USDI, Bureau of Land Management, 492 pp.
Engstrom, J., R. Jansson, C. Nilsson and C. Weber. 2011. Effects of river ice on riparian
vegetation. Freshwater biology 56: 1095-1105.
Flanagan, L.B. and J.R. Ehleringer. 1991. Stable isotope composition of stem and leaf water:
applications to the study of plant water use. Functional Ecology 5: 270-277.
Franz, E.H. and F.A. Bazzaz. 1977. Simulation of vegetation response to modified hydrologic
regimes: a probabilistic model based on niche differentiation in a floodplain forest.
Ecology 58: 176-183.
Fritts, H.C. 1976. Tree Rings and Climate. New York: Academic Press.
Gower, J.C. 1971. A general coefficient of similarity and some of its properties. Biometrics
27:857-871.
Granier, A. 1987. Evaluation of transpiration in a Douglas fir stand by means of sap flow
measurements. Tree Physiology 3: 309-320.
Harbaugh, A.W., 2005, MODFLOW-2005, the U.S. Geological Survey modular ground-water
model -- the Ground-Water Flow Process: U.S. Geological Survey Techniques and
Methods 6-A16.
Harza-Ebasco 1985. Riparian vegetation success report. Draft June 1985. Prepared by
University of Alaska for Harza-Ebasco and Alaska Power Authority. 170 pp.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 43 February 2014 Draft
Helm, D.J., and W.B. Collins. 1997. Vegetation succession and disturbance on a boreal forest
floodplain, Susitna River, Alaska. Canadian Field-Naturalist 111: 553–566.
Henszey, R.J., K. Pfeiffer, and J.R. Keough. 2004. Linking surface and ground-water levels to
riparian grassland species along the Platte River in Central Nebraska, USA. Wetlands 24:
665-687.
Hurlbert, S.H. 1984. Pseudoreplication and the design of ecological field experiments.
Ecological Monographs 54:187–211.
Ingraham, N. and R. Criss. 1993. Effects on surface area and volume on the rate of isotopic
exchange between water and water vapor. Journal of Geophysical Research 98(D11):
doi: 10.1029/93JD01735. issn: 0148-0227.
Jackson, R. B. 1999. The importance of root distributions for hydrology, biogeochemistry, and
ecosystem functioning. In: Integrating Hydrology, Ecosystem Dynamics, and
Biogeochemistry in Complex Landscapes (Eds. J. Tenhunen, P. Kabat, Dahlem
Conference), pp. 219-240. John Wiley and Sons, Chichester.
Karrenberg, S., P.J. Edwards and J. Kollmann. 2002. The life history of Salicaceae living in the
active zone of floodplains. Freshwater Biology 47: 733-748.
Kulmatiski, A., K.H. Beard, and J.M. Stark. 2006. Exotic plant communities shift water-use
timing in a shrub-steppe ecosystem. Plant and Soil 288(1-2): 271-284.
Lajtha, K. and J. Marshall. 1994. Sources of variation in the stable isotopic composition of
plants. In: Stable isotopes in ecology and environmental science. (Eds. K Lajtha and R H
Michener) p. 316. Wiley-Blackwell.
Legendre, P. and L. Legendre. 2012. Numerical Ecology. Third English Edition. Elsevier,
Amsterdam, The Netherlands.
LeRoux, X., T. Bariac, and A. Mariotti. 1995. Spatial partitioning of the soil water resource
between grass and shrub components in a West African humid savanna. Oecologia
104(2): 147-155.
Ludwig, F., T.E. Dawson, H.H.T. Prins, F. Berendse and H. Kroon. 2004. Belowground
competition between trees and grasses may overwhelm the facilitative effects of
hydraulic lift. Ecology letters 7(8): 623-631.
Maddock, T. III, K.J. Baird, R.T. Hanson, W. Schmid, and H. Ajami. 2012. RIP-ET: A riparian
evapotranspiration package for MODFLOW-2005: U.S. Geological Survey Techniques
and Methods 6-A39, 76 p.
Mahoney, J.M. and S.B. Rood. 1998. Stream flow requirements for cottonwood seedling
recruitment−an integrative model. Wetlands 18: 634-645.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 44 February 2014 Draft
Merritt, D.M., M.L. Scott, N.L. Poff, G.T. Auble and D.A. Lytle. 2010. Theory, methods and
tools for determining environmental flows for riparian vegetation: riparian vegetation
flow response guilds. Freshwater Biology 55: 206-225.
Montgomery, D. 1999. Process domains and the river continuum. Journal of the American
Water Resources Association 35(2): 397-410.
Mouw, J.B., J.A. Stanford, and P.B. Alaback. 2009. Influences of flooding and hyporheic
exchange on floodplain plant richness and productivity. River Research and Applications
25: 929-945.
Mouw, J.E.B., J.L. Chaffin, D.C. Whited, F.R. Hauer, P.L. Matson and J.A. Stanford. 2012.
Recruitment and successional dynamics diversify the shifting habitat mosaic of an
Alaskan floodplain. River Research and Applications. Published online in Wiley Online
Library (wileyonlinelibrary.com) DOI: 10: 10.1002/rra.2569.
Mueller-Dombois, D. and H. Ellenberg. 1974. Aims and Methods of Vegetation Ecology.
Wiley, New York.
Naiman, R.J., K.L. Fetherston, S.J. McKay, and J. Chen. 1998. Riparian forests. Chapter 12 In
Naiman, R.J. and R.E. Bilby, River Ecology and Management, Lessons from the Coastal
Pacific Northwest. Springer, New York.
Prowse, T.D. and S. Beltaos. 2002. Climatic control of river-ice hydrology: a review.
Hydrological Processes 16: 805-822.
Prowse, T.D. and J.M. Culp. 2003. Ice break-up: a neglected factor in river ecology. Canadian
Journal of Civil Engineering 30: 128-144.
R Development Core Team. 2011. R: A language and environment for statistical computing. R
Foundation for Statistical Computing, Vienna, Austria. ISBN 3-900051-07-0, URL
http://www.R-project.org/.
R2 Resource Consultants. 2013. Technical memorandum: Adjustments to Middle River Focus
Areas. Prepared for Alaska Energy Authority. May 2013.
R2 (R2 Resource Consultants, Inc.) 2013b. Technical Memorandum, Selection of Focus Areas
and Study Sites in the Middle and Lower Susitna River for Instream Flow and Joint
Resource Studies – 2013 and 2014. Susitna-Watana Hydroelectric Project, FERC No. P-
14241. Prepared for Alaska Energy Authority, Anchorage, Alaska. 88 pp. March 2013.
http://www.susitna-watanahydro.org/wp-content/uploads/2013/03/Attachment-C.pdf.
R2 Resource Consultants, Inc., GW Scientific and ABR, Inc. 2013. Technical Memorandum:
Riparian IFS, Groundwater and Riparian Vegetation Studies FERC Determination
Response. Prepared for AEA June 2013. 12 pp.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 45 February 2014 Draft
Rains, M.C., J.F. Mount, and E.W. Larsen. 2004. Simulated changes in shallow groundwater
and vegetation distributions under different reservoir operations scenarios. Ecological
Applications 14: 192-207.
Richards, K., J. Brasington and F. Hughs. 2002. Geomorphic dynamics of floodplains
ecological implications and a potential modeling strategy. Freshwater Biology 47: 559-
579.
Rood, S.B., S.G. Bigelow and A.A. Hall. 2011. Root architecture of riparian trees: river cut
banks provide natural hydraulic excavation, revealing that cottonwoods are facultative
phreatophytes. Trees 25: 907-917.
Rood, S.B., J.H. Braatne and F.M.R. Hughs. 2003. Ecophysiology of riparian
cottonwoods:stream flow dependency, water relations and restoration. Tree Physiology
23: 1113-1124.
Rood, S.B., L.A. Goater, J.M. Mahoney, C.M. Pearce and D.G. Smith. 2007. Floods, fire, and
ice: disturbance ecology of riparian cottonwoods. Canadian Journal of Botany 85: 1019-
1032.
Rood, S.B., G.M. Samuelson, J.H. Braatne, C.R. Gourley, F.M.R. Hughes, and J.M. Mahoney.
2005. Managing river flows to restore floodplain forests. Frontiers in Ecology and the
Environment 3(4): 193-201.
Scholl, M. 2006. Precipitation isotope collector designs. U.S. Geological Survey, 02 Feb 2006.
Web. March 5, 2013.
Soil Survey Staff. 2009. Soil survey field and laboratory methods manual. Soil Survey.
Investigations Report No. 51, Version 1.0. R. Burt (ed.). U.S. Department of Agriculture,
Natural Resources Conservation Service.
Springer, A.E., J.M. Wright, P.B. Shafroth, J.C. Stromberg and D.T. Patten. 1999. Coupling
groundwater and riparian vegetation models to assess effects of reservoir releases. Water
Resources Research 35: 3621-3630.
Stella, J.C., J.J. Battles, B.K. Orr, and J.R. McBride. 2006. Synchrony of seed dispersal,
hydrology and local climate in a semi-arid river reach in California. Ecosystems 9: 1200-
1214.
Stoffel, M. and M. Bollschweiler. 2008. Tree-ring analysis in natural hazards research – an
overview. Nat. Hazards Earth Syst. Sci., 8, 187–202.
Tetra Tech. 2013. Initial Geomorphic Reach Delineation and Characterization, Middle and
Lower Susitna River Segments. Draft 2012 Study Technical Memorandum prepared for
Alaska Energy Authority, February 12, 2013. 34 pp.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 46 February 2014 Draft
Viereck, L.A., C.T. Dyrness, A.R. Batten, and K.J. Wenzlick, K.J. 1992. The Alaska vegetation
Classification. Gen. Tech. Rep. PNW-GTR-286. Portland, OR: U.S. Department of
Agriculture, Forest Service, Pacific Northwest Research Station. 278 p
Walker, L.R., and F.S. Chapin III. 1986. Physiological controls over seedling growth in primary
succession on an Alaskan floodplain. Ecology 67: 1508-1523.
Walker, L.R., J.C. Zasada, and F.S. Chapin, III. 1986. The role of life history processes in
primary succession on an Alaskan floodplain. Ecology 67: 1243-1253.
Wilson, K. B., P.J. Hanson, P.J. Mulholland, D.D. Baldocchi and S.D. Wullschleger. 2001. A
comparison of methods for determining forest evapotranspiration and its components:
sap-flow, soil water budget, eddy covariance and catchment water balance. Agricultural
and Forest Meteorology 106(2): 153-168.
Winter, T.C. 2001. The concept of hydrologic landscapes. Journal of the American Water
Resources Association 37: 335-349.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 47 February 2014 Draft
9. TABLES
Table 4.1-1. Floodplain Vegetation and Physical Process Regimes Critical Review, Synthesis and Lessons Learned.
STUDY OBJECTIVES
1. Conduct a critical review of previous Susitna River 1980s floodplain vegetation studies.
2. Conduct a critical review, and synthesis of relevant findings, of circumpolar, temperate and boreal regions, scientific
research concerning dam effects on down river floodplain plant communities.
3. Conduct critical review, and synthesis of relevant current scientific research, concerning temperate and boreal
floodplain forest succession and dynamics under natural flow regimes.
METHODS
1. Search libraries and internet for relevant scientific literature.
2. Develop annotated, searchable bibliography.
3. Develop critical review paper with thematic format:
a. first, identify critical floodplain ecological processes effected by dams,
b. second, compare Project dam operations under current design and compare with scientific literature
reported effects,
c. third, identify potential alternative operation scenarios to limit effects.
EXPECTED RESULTS
1. State of the science review of scientific findings concerning dam effects on down river floodplain plant communities.
2. Summary of expected effects of Project operations on Susitna River floodplain plant communities and ecosystems.
3. Set of guidelines for limiting Project operations effects based on current science.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 48 February 2014 Draft
Table 4.2-1. Focus Area Selection−Riparian Process Domain Delineation.
STUDY OBJECTIVES
1. Develop a riparian process domain stratification of the study area.
2. Select Focus Areas representative of each riparian process domain for physical process and vegetation survey
sampling and modeling.
METHODS
1. Riparian process domain delineation, and riparian Focus Area selection is an iterative process.
2. In Q1 21013 the results of the 2012 Fluvial Geomorphology Modeling Study and channel classification (Section 6.6),
ice processes study (Section 7.6), riparian botanical survey (Section 11.6) were used to classify channel, floodplain
and floodplain vegetation types.
3. Constrained cluster analysis will be performed on channel, floodplain and vegetation types.
4. Process domain type variability was statistically described and analyses were performed to determine the number of
Focus Areas necessary to capture process domain variability in the stratified sampling approach.
5. Candidate Focus Areas previously identified through the expert-opinion process for both Fish and Aquatics IFS (FA-
IFS) and Riparian IFS were reviewed.
6. Results of the cluster analysis, power analysis and expert-opinion process will be presented to the TWG for final
selection of Focus Areas.
7. Ice process mapping results, completed in Q4 2013, will be used in a second round of riparian process domain
analysis and Focus Area selection.
8. Results of second iterative analysis will be used to assess whether additional Focus Areas are needed to capture ice
process effects for subsequent field sampling.
EXPECTED RESULTS
1. Hierarchical stratification of Susitna River Study Area into riparian process domains.
2. Statistically robust selection of representative riparian process domain Focus Areas.
3. Study Area floodplain vegetation and physical process sampling and characterization necessary to support model
scaling of Focus Area study results to riparian process domain.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 49 February 2014 Draft
Table 4.3-1. Synchrony of Seed Dispersal, Hydrology, and Local Susitna River Valley Climate.
STUDY OBJECTIVES
1. Measure balsam poplar and select willow species seed dispersal timing.
2. Model local Susitna River valley climate, and associated seasonal peak flows, relative to balsam poplar and willow
seed dispersal.
3. Develop a recruitment box model of seed dispersal timing, river flow regime, and balsam poplar and willow seed
dispersal and establishment.
METHODS
1. Conduct a two-year field survey of seed release of balsam poplar and select willow species.
2. Develop a ‘degree-day’ climate model for the onset of seed release relative to local temperature conditions using
methods developed by Stella et al. (2006).
3. Analyze the historic climate and Susitna River flow regime relationship.
EXPECTED RESULTS
1. Degree-day model of peak seed release window using seed release observations and continuous temperature records
from each floodplain sample site.
2. Recruitment box model of balsam poplar and select willow species.
3. Model of peak runoff / seed release temporal synchrony for operational flow guidelines.
4. Model of critical summer flow regime necessary to support seedling establishment.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 50 February 2014 Draft
Table 4.3-2. Seedling Establishment and Recruitment Study.
STUDY OBJECTIVES
1. Map and characterize seedling establishment and recruitment of dominant woody riparian species including balsam
poplar, white spruce, paper birch, thinleaf and mountain alder, feltleaf willow, and Barclay’s willow throughout the
Focus Area lateral channel margins, and floodplains.
1. .Use a stratified random sampling approach, with variable plot sizes (Mueller-Dombois and Ellenburg 1974) to sample
mapped seedling polygons.
2. Identify seedlings to species, and measure seedling heights and density.
3. Describe and measure seedling site soil characteristics
4. Measure and model seedling site GW/SW hydroregimes.
5. Measure seedling xylem water source through isotopic analysis
6. Investigate ice process seedling site interactions through empirical observations and ice process modeling.
7. Develop a probabilistic model of seedling hydrologic, sediment, and ice regime processes.
METHODS
1. Survey sampling approach is as follows.
2. First, helicopter and on-the-ground reconnaissance surveys of each reach were conducted to locate and map
observable seedling areas.
3. Second, four to eight transects were placed systematically throughout the reach normal to main channel, extending
across the adjacent floodplain intersecting observed seedling sites. Each transect was traversed and all remotely
observed, and newly identified on-the-ground seedling locations were mapped with GPS.
4. Third, seedling site polygon boundaries were mapped with GPS.
5. Fourth, seedling patches were sampled using a stratified random approach to locate sample plots. Seedling species
were identified, or collected for herbarium identification, and abundance (density) and height measured using variable
plot size and shapes (Elzinga et al. 1998; Mueller-Dombois and Ellenberg 1974).
6. Fifth, at each plot two to three seedlings of each species were excavated and rooting depth measured. Excavated
woody seedlings were aged at the root collar in the laboratory and annual rings counted to provide seedling age.
Substrate texture and depth to cobbles were described and measured in soil pits excavated to 50 cm in depth or to
gravel/cobble refusal layer.
7. Sixth, a subsample of Focus Area site seedlings was collected for xylem isotopic analyses to identify source of water
(see Section 8.6.3.6).
8. Seedling establishment model will be developed using techniques and methods described in Franz and Bazzaz (1977),
Rains et al. (2004), Henszey et al. (2004), Baird and Maddock (2005), and Maddock et al. (2012).
EXPECTED RESULTS
1. Probabilistic model of seedling establishment requirements based on GW/SW interaction model, sediment transport
model, and ice regime model.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 51 February 2014 Draft
Table 4.4-1. Characterize the role of river ice in the establishment and recruitment of dominant floodplain vegetation.
STUDY OBJECTIVES
1. Develop an integrated model of ice process interactions with floodplain vegetation.
2. Conduct primary research to identify the effects of ice on floodplain vegetation within mapped Susitna River ice
floodplain impact zones.
3. Quantitatively describe and compare ice influenced and non-ice-influenced floodplain plant community composition,
abundance, age, and spatial pattern to assess the role and degree of influence ice processes have on Susitna River
floodplain vegetation.
4. Provide Project operational guidance on potential effects of operations flow on ice formation and floodplain vegetation
development.
METHODS
1. Multiple lines of evidence will be used to inform a final research study design to address the question of vegetation
response to ice shearing influence on the Susitna River floodplain.
2. First, ice vegetation impacts (tree ice-scars) will be observed, mapped, and aged (using dendrochronologic
techniques), and gravel floodplain deposits will be mapped throughout the Study Area to develop a map of river ice
floodplain vegetation interaction domains.
3. Local, sub-reach scale, floodplain vegetation ice disturbance effects were mapped and characterized in 2013.
Additional forest scale ice disturbance effects will be characterized and sampled.
4. Interviews of local Susitna River residents concerning knowledge of ice dam locations and ice process effects.
5. Comparative quantitative vegetation study of ice effects on identified ice floodplain impact and un-impacted zones.
Methods will build on those presented in Engstrom et al. (2011).
6. Integration of ice process modeling results with empirical ice vegetation mapping and ice vegetation interaction studies.
EXPECTED RESULTS
1. Ice processes domain and floodplain ice interaction geographic, and elevation, map to inform floodplain ice interaction
vegetation study design and ice processes modeling, Section 7.6.
2. Develop a floodplain vegetation ice processes interaction study to compare ice disturbed and un-disturbed floodplains.
The results of the study will be used to assess how floodplain vegetation pattern and process may change with Project
operation alterations of the natural ice process regime. The final study design will be completed in Q2-3 2013, as
additional tree ice-scar field data become available.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 52 February 2014 Draft
Table 4.5-1. Characterize the role of erosion and sediment deposition in the formation of floodplain surfaces, soils, and
vegetation.
STUDY OBJECTIVES
1. Measure the rates of channel migration, and floodplain vegetation disturbance or turnover, throughout the Study Area.
2. Measure the rates of sediment deposition, and floodplain development, throughout the Study Area.
3. Assess / model how Project operations will effect changes in the natural sediment regime, floodplain depositional
patterns, and soil development throughout the Study Area.
4. Assess / model how Project operations changes in sediment transport and soil development will affect floodplain plant
community succession.
METHODS
1. Floodplain soils and stratigraphy will be sampled throughout the Study Area using a stratified random approach,
including pits located in all Focus Areas.
2. Floodplain soil pits will be excavated from the surface to gravel / cobble layer (historic channel bed) and soil
stratigraphy will be described and measured using standard NRCS field techniques (Schoeneberger et al. 2002).
Standard sediment grain size sieve analysis will be conducted on the entire sediment profile.
3. Direct dating of fluvial sediments will be conducted using isotopic techniques, including, but not limited to, 137Cs and
210Pb measurements as described in Stokes and Walling (2003), Aalto (2003), and Aalto et al (2008).
4. Dendrochronologic techniques (Fritts 1976) will be used to age trees and current floodplain surfaces at each soil pit.
EXPECTED RESULTS
1. Dating of floodplain stratigraphy and surfaces using direct isotopic and dendrochronologic techniques for development
of floodplain evolution model,
2. Floodplain stratigraphic descriptions and grain size analyses for development of floodplain evolution model and
sediment transport modeling.
3. Measurement of rate of channel migration disturbance of floodplain vegetation. Measurement of rate of floodplain
turnover or disturbance.
4. Model of how Project operations will effect soil development.
5. Model of alteration of riparian seedling establishment floodplain surfaces and floodplain vegetation succession.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 53 February 2014 Draft
Table 4.6-1. Characterize natural floodplain vegetation groundwater and surface water maintenance hydroregime.
STUDY OBJECTIVES
1. Characterize dominant floodplain woody plant species establishment and maintenance life stage water sources
through stable isotope analyses of groundwater, soil water, and xylem water.
2. Measure groundwater and surface water regime at Focus Areas (GW: depth seasonally; SW: river stage)
3. Develop a floodplain GW/SW interaction model (water level frequency, magnitude, depth, duration, timing, interaction
response).
4. Develop floodplain vegetation-flow response models.
5. Model Project operational flow effects on floodplain plant communities.
METHODS
1. Focus Area GW / SW sampling for sampled floodplain plant community types and successional stages including plant
establishment, plant recruitment, and mature forest vegetation.
2. Sampling design will include transects and arrays of groundwater wells and surface water stage stations see
Groundwater Study Section 7.5 for details.
3. Riparian floodplain plant community and soils sampling approach and design is detailed in the Riparian Vegetation
Study Section 11.6.
4. Woody species source of water will be directly determined from stable isotope analyses of groundwater, soil water,
precipitation, and xylem water hydrogen and oxygen.
5. The rooting depth of dominant floodplain plants will be measured through excavation of trenches within each Focus
Area floodplain plant community type in coordination with soil stratigraphic excavations and well point soil pits.
6. Probabilistic response curves will be developed for select plant species and all riparian plant community types using
techniques described in Rains et al. (2004) and Henszey et al. (2004).
EXPECTED RESULTS
1. Probabilistic response curves for select plant species and sampled riparian plant community types.
2. Floodplain vegetation-GW/SW regime functional groups.
3. Statistically modeled relationship between individual riparian species, floodplain plant community types, and natural
GW/SW hydroregime.
4. Model of potential effects of Project operations on Susitna River floodplain plant communities.
5. Basis for recommended flow prescriptions necessary to support floodplain vegetation establishment, recruitment, and
maintenance.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 54 February 2014 Draft
Table 4.7-1. Floodplain Vegetation Study Synthesis, Focus Area to Riparian Process Domain Model Scaling and Project
Operations Effects Modeling.
STUDY OBJECTIVES
Study objectives are to:
1. Develop conceptual ecological model of Susitna River floodplain vegetation establishment and recruitment based on
synthesis of Riparian Vegetation Study and Riparian IFS results.
2. Scale-up results of Focus Area floodplain vegetation and physical process modeling results to riparian process
domains.
3. Develop a dynamic spatially-explicit floodplain vegetation model for simulating floodplain vegetation response to
Project operation modification of the natural flow, sediment and ice processes regimes.
4. Develop spatially explicit maps of modeled Project operations effects throughout the Study Area.
5. Provide guidance to environmental analysis of Project operations.
METHODS
1. Develop a dynamic spatially-explicit floodplain vegetation model for simulating floodplain vegetation response to
Project operation modification of the natural flow, sediment and ice processes regimes (Franz and Bazzaz 1976;
Benjankar et al. 2011; Springer et al. 1999).
2. Fluvial Geomorphology Modeling Study 6.6, Ice Processes Study 7.6, and Groundwater Study 7.5 modeling studies
will provide modeling results of both existing conditions and Project operation scenarios.
3. Riparian botanical forest succession models synthesis.
4. Floodplain vegetation (individual plant species and community types) GW/SW flow response curve analyses and
physical process models (fluvial geomorphology, groundwater, ice processes) will be used to model floodplain
vegetation transition dynamics at riparian process domain scale.
5. Focus Area modeling will be scaled-up to the riparian process domains using spatially explicit GIS models.
EXPECTED RESULTS
1. Conceptual ecological model of Susitna River floodplain vegetation establishment and recruitment floodplain
vegetation.
2. Dynamic spatially-explicit floodplain vegetation model for simulating floodplain vegetation response to Project operation
modification of the natural flow, sediment and ice processes regimes.
3. Riparian process domain scale model of floodplain vegetation and physical processes.
4. Spatially explicit maps of modeled Project operations floodplain vegetation effects throughout the Study Area.
5. Project operations guidance to minimize modeled floodplain vegetation effects.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 55 February 2014 Draft
Table 5.2-1. Riparian process domain #1 (RPD1).
Plant communities typed, and measured, along transects using Alaska Vegetation Classification (AVC) Level III (1992) community descriptions.
First column describes communities identified along transects in RPD1 and remaining columns describe communities within Focus Areas in the
riparian process domain. The sum of lengths (line-intercept sampling method; length in meters) for each cover type are reported in
parentheses.
Plant Community RPD1 (PRM 168.25-187) FA-184 Watana Dam FA-173 Stephan Lake Complex FA-171 Stephan Lake Simple
Closed Conifer Forest Yes
(3625.5) No Yes
(44.4)
Yes
(134)
Open Conifer Forest Yes
(7080.3)
Yes
(69.9)
Yes
(407.9)
Yes
(111)
Conifer Woodland Yes
(849.7)
Yes
(105.4) No No
Closed Mixed Forest Yes
(2912)
Yes
(81.1)
Yes
(268.3)
Yes
(314.1)
Open Mixed Forest Yes
(5567.7)
Yes
(134.7)
Yes
(746)
Yes
(715.4)
Mixed Woodland Yes
(250.8) No Yes
(77.7)
Yes
(35.9)
Closed Broadleaf Forest Yes
(250.7)
Yes
(8.5)
Yes
(81.5) No
Open Broadleaf Forest Yes
(329.4) No Yes
(156.8)
Yes
(13.1)
Broadleaf Woodland Yes
(31.3) No No No
Closed Alder/Willow Shrub Yes
(750.9)
Yes
(28.4)
Yes
(246.9)
Yes
(24.8)
Open Alder/Willow Shrub Yes
(585.6)
Yes
(35)
Yes
(155.5)
Yes
(47)
Herbaceous Yes
(470.8) No Yes
(47.4) No
Partially Vegetated Yes
(228.4)
Yes
(27.7)
Yes
(119.7)
Yes
(25.4)
Non-vegetation cover types1 Yes
(16012.4)
Yes
(810.8)
Yes
(1857.3)
Yes
(1164.2)
Total Transect Length 38945.4 1301.6 4209.4 2585.0
# of Plant Communities 13 8 11 9
percent Plant Communities overlap with
RPD1 100 percent 62 percent 85 percent 69 percent
Notes:
1 Includes channel types (main channel, side channel, side slough, upland slough, etc.) as well as roads, and other human disturbances.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 56 February 2014 Draft
Table 5.2-2. Riparian process domain #3 (RPD3) plant communities typed, and measured, along transects using Alaska
Vegetation Classification (AVC) Level III (1992) community descriptions.
First column describes communities identified along transects in RPD3 and remaining columns describe communities within Focus Areas in the
riparian process domain. The sum of lengths (line-intercept sampling method; length in meters) for each cover type are reported in
parentheses.
Plant Community
RPD3
(PRM 108-153.5)
FA-151
Portage Creek
FA-144 Side
Channel 21
FA-141
Indian River
FA-138
Gold Creek
FA-128 Skull
Creek Complex
FA-115
Lane Creek
Closed Conifer Forest No No No No No No No
Open Conifer Forest Yes
(1243.9) No No No No No No
Conifer Woodland Yes
(307.6) No No No No No No
Closed Mixed Forest Yes
(5325.2) No Yes
(20.8) No No No No
Open Mixed Forest Yes
(15444.3)
Yes
(40.1)
Yes
(30.4)
Yes
(490.5)
Yes
(257.6)
Yes
(7.6)
Yes
(322.6)
Mixed Woodland Yes
(6053.8) No Yes
(125.5)
Yes
(215.4)
Yes
(73.7)
Yes
(816.8)
Yes
(233)
Closed Broadleaf Forest Yes
(10657.8) No Yes
(645.7)
Yes
(328)
Yes
(1230)
Yes
(307.9)
Yes
(263)
Open Broadleaf Forest Yes
(17955.5)
Yes
(9.5)
Yes
(403.1)
Yes
(140)
Yes
(1271.9)
Yes
(2240.5)
Yes
(674.6)
Broadleaf Woodland Yes
(3480.4)
Yes
(31.2) No No No Yes
(61.9)
Yes
(197.1)
Closed Alder/Willow Shrub Yes
(6008.8)
Yes
(24)
Yes
(232.9)
Yes
(34.9)
Yes
(439.5)
Yes
(268.8)
Yes
(21.5)
Open Alder/Willow Shrub Yes
(6188.6) No Yes
(327.1)
Yes
(330.9)
Yes
(223.3)
Yes
(307.1)
Yes
(61.2)
Herbaceous Yes
(4138.2) No No No Yes
(234.9)
Yes
(21.3)
Yes
(183.5)
Partially Vegetated Yes
(677) No Yes
(10.6)
Yes
(48.9)
Yes
(50.9) No No
Non-vegetation cover types1 Yes
(65375.2)
Yes
(456)
Yes
(2808.3)
Yes
(2360.6)
Yes
(1944.8)
Yes
(3313.2)
Yes
(2553.4)
Total Transect Length 142856 561 4604 3949 5727 7345 4510
# of Plant Communities 12 4 9 7 8 8 8
percent Plant Communities
overlap with RPD3
100
percent
33
percent
75
percent
58
percent
67
percent
67
percent
67
percent
Notes:
1 Includes channel types (main channel, side channel, side slough, upland slough, etc.) as well as roads, and other human disturbances.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 57 February 2014 Draft
Table 5.2-3. Riparian process domain #4 (RPD4) plant communities typed, and measured, along transects using Alaska
Vegetation Classification (AVC) Level III (1992) community descriptions.
First column describes communities identified along transects in RPD4 and remaining columns describe communities within Focus Areas in the
riparian process domain. The sum of lengths (line-intercept sampling method; length in meters) for each cover type are reported in
parentheses.
Plant Community RPD4 (PRM 104-107.75) Whiskers Slough
Closed Conifer Forest No No
Open Conifer Forest Yes
(557.3)
Yes
(71.5)
Conifer Woodland Yes
(87) No
Closed Mixed Forest Yes
(5285.1)
Yes
(109.6)
Open Mixed Forest Yes
(20752.7)
Yes
(10185.8)
Mixed Woodland Yes
(2727.7)
Yes
(820)
Closed Broadleaf Forest Yes
(2776.5)
Yes
(994.1)
Open Broadleaf Forest Yes
(1328.1)
Yes
(831.1)
Broadleaf Woodland Yes
(607.7)
Yes
(180.5)
Closed Alder/Willow Shrub Yes
(320.5)
Yes
(313.6)
Open Alder/Willow Shrub Yes
(508.9)
Yes
(185.3)
Herbaceous Yes
(2198.3)
Yes
(770.3)
Partially Vegetated Yes
(290.3)
Yes
(100)
Non-vegetation cover types1 Yes
(7020.7)
Yes
(2848.1)
Total Transect Length 44461 17410
# of Plant Communities 12 11
percent Plant Communities overlap with RPD4 100 percent 92 percent
Notes:
1 Includes channel types (main channel, side channel, side slough, upland slough, etc.) as well as roads, and other human disturbances.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 58 February 2014 Draft
Table 5.2-4. Rationale for Riparian IFS Focus Area selection
Focus Area ID Common Name Riparian IFS Riparian IFS Selection Rationale
Focus Area-184 Watana Dam
Not-selected. Floodplain vegetation occurs on only a few
mid-channel island bars. Non-focus area vegetation
sampling will be conducted in these areas.
Focus Area-173 Stephan Lake,
Complex Channel X
Focus Area captures the diversity of floodplain vegetation
types in the upper moderately confined riparian process
domain from the dam site to Devils Canyon.
Focus Area-171 Stephan Lake,
Simple Channel
Not-selected. Approximately 0.5 miles south of FA-173.
Similar vegetation types but less floodplain terrain
complexity.
Focus Area-151 Portage Creek Not-selected. Steep valley walls immediately adjacent to
channel. Floodplain vegetation is minimal.
Focus Area-144 Side Channel 21
Not-selected. Process domain representative vegetation,
however, lacking in off-channel water body and wetland
complexity.
Focus Area-141 Indian River Not selected. Very limited floodplain area.
Focus Area-138 Gold Creek X Representative floodplain vegetation types and river right
beaver dam wetland complex.
Focus Area-128 Skull Creek
Complex X Representative floodplain vegetation types and complex
off-channel water bodies and associated wetlands.
Focus Area-115 Lane Creek X
Representative floodplain vegetation types and off-
channel water bodies associated with beaver dam
wetland complex.
Focus Area-104 Whiskers Slough X
Transition riparian process domain between, Three
Rivers confluence and moderately confined riparian
process domain. Representative floodplain vegetation
types and off-channel water bodies and associated
beaver dam wetland complexes.
Table 5.2-5. List of Focus Areas selected for Riparian-IFS studies within each Riparian Process Domain.
Middle River
Riparian Process
Domain
Location (PRM) Associated Riparian-IFS Focus Areas Upstream Downstream Focus Area ID Common Name
Location (PRM) Upstream Downstream RPD1 187 168.25 Focus Area-173 Stephan Lake, Complex Channel 175.4 173.6
RPD2 168 153.75 None N/A N/A N/A
RPD3 153.5 108
Focus Area-138 Gold Creek 140 138.7
Focus Area-128 Skull Creek Complex 129.7 128.1
Focus Area-115 Lane Creek 116.5 115.3
RPD4 107.75 104 Focus Area-104 Whiskers Slough Complex 106 104.8
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 59 February 2014 Draft
Table 5.3-1. Number and species of Salix and Populus surveyed at each of four seed release study sites located in the
Lower and Middle Segments on the Susitna River.
PRM (Site Name)
Number of Shrubs Shrub Species Number of Trees Tree Species
PRM 47
(Deshka Landing)
6 Salix alaxensis 6 Populus balsamifera 6 Salix barclayi
PRM 88
(Parks Highway Bridge)
5 Salix alaxensis 6 Populus balsamifera 1 Salix sitchensis
PRM 102
(Talkeetna) 6 Salix barclayi 6 Populus balsamifera
PRM 142
(Indian River)
5 Salix alaxensis 6 Populus balsamifera 7 Salix sitchensis
Table 5.3-2. Day of year when plants have released 20 percent (DY20) and 80 percent (DY80) of seeds based on 2013 data.
Values are averaged by site and species for site/species combinations with >3 plants having estimable quantiles. (Julian Day 170 = June 19)
PRM (Site Name) Tree or Shrub Species Number of Plants DY20 DY80 Peak Seed Release Duration
PRM 47
(Deshka Landing) Populus balsamifera 6 170 177 7
PRM 88
(Parks Highway Bridge) Populus balsamifera 6 170 179 9
PRM 102
(Talkeetna) Populus balsamifera 6 171 179 7
PRM 142
(Indian River) Populus balsamifera 6 173 180 7
PRM 47
(Deshka Landing) Salix barclayi 6 170 198 29
PRM 88
(Parks Highway Bridge) Salix alaxensis 3 164 188 25
PRM 102
(Talkeetna) Salix barclayi 6 172 201 28
PRM 142
(Indian River) Salix sitchensis 5 166 182 17
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 60 February 2014 Draft
Table 5.3-3. Distribution of seedling establishment transects by Focus Area and geomorphic position.
Focus Area
Geomorphic Position FA-104 FA-113 FA-128 FA-138 FA-144 Total Transects
Island Head 2 2
Island Tail 2 2
Main Channel 4 4
Slough 6 6 2 14
Slough-Main Channel
Confluence 2 2 4
Side Channel 5 2 2 9
Total 5 12 8 4 6 35
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 61 February 2014 Draft
Table 5.3-4. Overview of spruce recruitment transect observations.
Transect
Island (PRM) Transect Number
Transect
Length (m) Transect Area (ha)
percent of Island in
Survey Area
Number
of Spruce Snags
Number of Spruce Trees
>1.4 m tall
Number
of Spruce <1.4 m tall
Average Tree (>1,4 m tall)
DBH (cm ± SD)
Average
Tree Height (m ± SD)
Average Seedling Spruce
Height (m ± SD)
Min-Max
Height (m)
105.1 1 210 0.17 6 percent 0 6 0 17.52 ± 7.98 10.25 ± 5.12 None 2.50 – 15
112.5 1 173 0.14
12
percent 2 27 3 11.63 ± 6.72 8.63 ± 4.11 0.55 ± 0.30 0.37 – 15
115.3 1 228 0.18 18
percent
0 2 0 12.40 ± 8.91 9.00 ± 7.07 None 4.00 – 14
115.3 2 260 0.21 3 18 0 18.56 ± 7.64 11.50 ± 3.85 None 3.00 – 16
114.5 1 315 0.25 10
percent
0 15 3 5.45 ± 3.16 3.90 ± 2.32 0.90 ± 0.52 0.53 – 8
114.5 2 322 0.26 1 44 3 7.02 ± 4.08 6.03 ± 3.64 0.75 ± 0.48 0.46 – 17
115.6 1 930 0.74 10
percent
6 27 0 22.29 ± 8.17 15.56 ± 5.04 None 5.50 - 25
115.6 2 980 0.78 1 14 0 25.14 ± 7.66 19.64 ± 3.71 None 13.00 - 24
128.1 1 280 0.22 19
percent
0 27 5 2.42 ± 1.39 2.53 ± 0.88 0.67 ± 0.25 0.30 - 4.5
128.1 2 258 0.21 0 5 30 2.08 ± 1.25 2.17 ± 0.79 0.60 ± 0.27 0.22 - 3.5
135 1 288 0.23 5 percent 0 11 84 2.09 ± 1.76 1.89 ± 0.55 0.80 ± 0.29 0.20 - 3.4
135 2 150 0.12 0 0 99 None None 0.65 ± 0.23 0.10 - 1.3
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 62 February 2014 Draft
Table 5.3-5. Trees sampled on spruce transect islands.
Island
(PRM)
Total number of Spruce
Cored/Cookied
Number of Spruce Sampled for
Sediment
Average Depth of Root Collar Burial
(cm ± SD)
Min - Max Depth of Root Collar Burial
(cm)
Average Depth to Armor
(cm ± SD)
Min - Max Depth to Armor
(cm)
Average Number of Organic Layers in First 30 cm
(± SD)
105.1 5 5 5.33 ± 11.24 -7 - 15 119.60 ± 5.64 110 - 123 3.80 ± 0.84
112.5 8 6 3.67 ± 3.93 0-9 78.50 ± 17.36 57 - 97 3.33 ± 0.82
115.3 8 6 7.67 ± 5.92 -3 - 13 87.58 ± 13.69 78 - 108 4.33 ± 1.86
114.5 6 10 11.33 ± 16.29 0 - 30 86.09 ± 10.50 72 - 108 3.27 ± 0.90
115.6 12 10 -3.63 ± 17.32 -31 - 25 81.29 ± 18.42 42 - 98 2.20 ± 0.63
128.1 7 7 13.00 ± 5.60 5 - 21 43.29 ± 15.86 28 - 76 2.57 ± 0.77
135 6 5 11.20 ± 7.46 6 - 24 72.00 ± 4.18 67 - 76 1.80 ± 0.84
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 63 February 2014 Draft
Table 5.5-1. Stem number and mean DBH for trees and selected shrubs at ITU sample plots.
Trees Shrubs
Preliminary Viereck
Classification
Focus
Area Site
Number of Stems Mean DBH (cm)
Standard
Deviation
(cm)
Number of
Stems
Mean
DBH
(cm)
Standard
Deviation
(cm)
Balsam Poplar Woodland 115 115-0813-KLBD-S3 10 34.5 56.7 None None None
Bluejoint Meadow
104 104-0815-KLBD-S4 2 5.7 0.4 55 1.4 0.8
115 115-070213-KKKLBD-S1 39 6.7 1.9 100 2.0 1.0
115-070213-KKKLBD-S2 7 13.5 19.5 24 1.5 0.9
115 Total 46 7.7 7.3 124 1.9 1.0
Closed Balsam Poplar
104
104-0626-KKKF-S2 30 31.8 15.9 27 2.4 1.0
104-0626-KKKF-S3 50 21.6 11.0 32 2.5 1.2
104-062713-KKKLBD-S2 26 23.2 24.5 14 2.3 1.5
104-062813-KKKLBD-S3 13 29.5 33.7 4 4.8 0.5
104-062913-KLMMBD-S3 28 21.9 24.3 None None None
104-063013-KKKLBD-S3 24 34.9 19.5 None None None
104 Total 171 26.2 19.7 77 2.5 1.2
115
115-070213-KKKLBD-S4 43 20.3 7.1 104 1.2 0.6
115-070213-KKKLBD-S5 45 20.1 10.4 53 1.3 0.5
115-0828-KFBD-S1 29 15.0 17.6 11 3.0 1.3
115-0907-KKKL-S1 31 22.4 27.4 15 3.7 1.2
115 Total 148 19.6 16.0 183 1.6 0.7
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 64 February 2014 Draft
Trees Shrubs
Preliminary Viereck
Classification
Focus
Area Site
Number of Stems Mean DBH (cm)
Standard
Deviation
(cm)
Number of
Stems
Mean
DBH
(cm)
Standard
Deviation
(cm)
Closed Poplar Woodland--
Alder Tall Shrub
104
104-0626-KKKF-S1 None None None 215 2.0 0.0
104-062713-KKKLBD-S1 None None None 317 1.6 0.6
104-063013-KKKLBD-S5 None None None 247 2.2 0.8
104 Total - - - 779 1.9 0.6
Closed Tall Alder-Willow 115 115-070213-KKKLBD-S6 2 6.4 0.5 179 2.4 1.0
Closed Tall Willow 128 128-0817-KFMMBD-S2 2 5.9 0.4 175 2.3 1.1
Ferns
104 104-062913-KLMMBD-S2 26 8.2 2.3 24 1.8 1.2
104-0808-KKKLBD-S3 12 12.9 14.2 6 2.0 0.6
104 Total 38 9.7 7.9 30 1.8 1.0
115 115-0813-KLBD-S2 2 15 0 None None None
Open Balsam Poplar Forest
104 104-0815-KLBD-S1 11 47.3 41.8 None None None
115
115-0809-KKKLBD-S3 17 37.4 20.1 3 1.3 0.6
115-0809-KKKLBD-S4 5 41.0 26.2 None None None
115-0813-KLBD-S4 9 33.9 43.9 None None None
115-0813-KLBD-S5 21 10.9 5.6 4 2.3 0.5
115-0814-KLBD-S1 5 86.0 15.6 None None None
115-0814-KLBD-S2 4 36.4 41.5 8 1.6 0.5
115 Total 61 32.0 22.7 15 1.7 0.5
128
128-0817-KFMMBD-S1 33 19.1 12.8 28 2.3 1.0
128-0817-KFMMBD-S4 8 30.2 37.9 21 3.9 1.0
128-0913-KKF-S1 44 10.7 5.0 79 2.1 1.3
128 Total 85 15.8 13.9 128 2.4 1.2
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 65 February 2014 Draft
Trees Shrubs
Preliminary Viereck
Classification
Focus
Area Site
Number of Stems Mean DBH (cm)
Standard
Deviation
(cm)
Number of
Stems
Mean
DBH
(cm)
Standard
Deviation
(cm)
Open Poplar Woodland-
Alder-Willow Tall Shrub 115 115-0818-MMBD-S2 611 1.7 0.7
Open Spruce-Balsam
Poplar Forest
104 104-063013-KKKLBD-S4 25 15.1 17.4 20 3.7 1.3
104-0808-KKKLBD-S1 3 36.6 21.0 None None None
104 Total 28 17.4 17.1 20 3.7 1.3
128 128-0817-KFMMBD-S3 10 38.7 39.1 9 3.8 0.8
Open Spruce-Paper Birch
104
104-062813-KKKLBD-S1 61 9.3 8.4 None None None
104-062813-KKKLBD-S2 20 20.8 11.5 35 2.6 1.0
104-062913-KLMMBD-S1 18 22.7 11.4 None None None
104-0808-KKKLBD-S2 8 20.0 15.2 4 3.5 0.6
104-0815-KLBD-S2 30 14.7 11.3 3 3.7 1.2
104-0815-KLBD-S3 19 23.8 15.2 2 4.0 0.0
104-0816-MMBD-S1 8 14.0 16.1 None None None
104 Total 164 15.6 11.1 46 0.7 0.3
115 115-0814-KLBD-S5 3 28.8 8.4 None None None
Spruce-Balsam Poplar
Woodland
104 104-063013-KKKLBD-S1 31 13.2 10.0 15 3.7 1.5
104-063013-KKKLBD-S2 33 10.5 9.8 26 3.5 1.2
104 Total 64 11.8 9.7 41 3.5 1.3
115
115-0809-KKKLBD-S1 52 9.0 7.0 34 3.5 1.3
115-0809-KKKLBD-S2 4 78.6 40.5 None None None
115-0813-KLBD-S1 3 7.5 1.0 None None None
115 Total 59 13.7 11.2 34 3.5 1.3
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 66 February 2014 Draft
Trees Shrubs
Preliminary Viereck
Classification
Focus
Area Site
Number of Stems Mean DBH (cm)
Standard
Deviation
(cm)
Number of
Stems
Mean
DBH
(cm)
Standard
Deviation
(cm)
Spruce-Paper Birch
Woodland
115 115-0814-KLBD-S3 40 13.0 10.5 78 2.2 1.3
115-0814-KLBD-S4 36 8.2 4.9 261 1.9 1.2
115 Total 76 10.7 8.3 339 2.0 1.2
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 67 February 2014 Draft
Table 5.6-1. Number of plant isotope samples collected by sample site and plant community structural type.
Plant Community Structural Type
Sample Period Herbaceous Shrub Tree Total
FA-104 June (Leaf-Out) 37 10 48 95
July (Mid-Summer) 34 38 35 107
September (Late-Summer) 35 50 30 115
Total FA-104 106 98 113 317
FA-128 June (Leaf-Out) 39 20 50 109
July (Mid-Summer) 55 43 25 123
September (Late-Summer) 45 45 20 110
Total FA-128 139 108 95 342
Grand Total 245 206 208 659
Table 5.6-2. Number of soil isotope samples by canopy cover type.
Canopy Cover Type
Number of Isotope Samples by Site
FA-104 FA-128
Alder/Willow 55 52
Poplar 29 116
Poplar/Spruce 42 65
Spruce/Birch 53 0
Old Spruce/Birch 55 0
Poplar/Alder 0 13
Open Alder 0 65
Total Samples 234 311
Table 5.6-3. Number of water isotope samples by site, month, and water source.
Number of Water Isotope Samples
Water Source
June
(Leaf-out)
July
(Mid-summer)
September (Late
summer) Total
FA-104 Groundwater 0 0 8 8
Main Channel 1 3 2 6
Precipitation 0 8 9 17
Slough 2 3 2 7
FA104 Total 3 14 21 38
FA-128
Groundwater 0 0 4 4
Precipitation 0 9 14 23
Side Channel 0 2 2 4
Slough 4 5 4 13
FA-128 Total 4 16 24 44
Talkeetna Precipitation 2 2 14 18
Grand Total 9 32 59 100
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 68 February 2014 Draft
Table 5.6-4. Number and species of trees and shrubs with sap flow instrumentation at each riparian GW/SW station.
Species
Station ID
Alnus incana ssp.
tenuifolia
Betula
papyrifera Picea glauca
Populus
balsamifera
Salix
spp. Total
ESGFA104-4
3 3 6
ESGFA104-6 2
2 4
ESGFA104-7
1 3
4
ESGFA104-8
3 3
6
ESGFA128-3 2
2 4
ESGFA128-5
2 3 1
6
ESGFA128-9 3
2 5
ESGFA128-10
3
3
Total 7 8 10 7 6 38
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 69 February 2014 Draft
Table 5.6-5. List of species sampled for stomatal conductance at each Focus Area.
Note: All species scientific names are consistent with current nomenclature listed at plants.usda.gov, common names follow Viereck et al
(1992) and Hulten (1968).
Species Focus Area
Scientific Name Common Name FA 104 FA 115 FA 128 Total
Trees
Populus balsamifera balsam poplar 13 0 8 21
Betula papyrifera paper birch 10 0 12 22
Picea glauca white spruce 18 0 18 36
Shrubs
Sambucus racemosa red elderberry 8 0 0 8
Alnus sinuata Sitka alder 0 0 1 1
Alnus viridis ssp. crispa mountain alder 186 21 98 305
Alnus incana ssp. tenuifolia thinleaf alder 91 54 72 217
Rosa acicularis Arctic rose 121 94 52 267
Salix barclayi Barclay's willow 113 10 85 208
Salix bebbiana Bebb willow 0 0 37 37
Salix alaxensis feltleaf willow 48 2 57 107
Viburnum edule highbush cranberry 162 56 154 372
Rubus idaeus American red raspberry 26 15 60 101
Ribes triste red currant 78 2 68 148
Herbs
Calamagrostis canadensis bluejoint 170 121 115 406
Heracleum lanatum common cowparsnip 108 57 96 261
Delphinium glaucum Sierra larkspur 8 0 12 20
Oplopanax horridus devils club 88 7 58 153
Dryopteris expansa spreading woodfern 10 5 4 14
Chamerion angustifolium ssp.
angustifolium fireweed 84 83 92 259
Gymnocarpium dryopteris western oakfern 2 0 12 14
Matteuccia struthiopteris ostrich fern 185 64 114 363
Streptopus amplexifolius watermelon berry 77 0 53 130
Trientalis europaea arctic starflower 20 0 6 26
Carex spp. sedge species 11 88 2 101
Total 1637 679 1286 3602
Table 5.6-6. Number of stomatal conductance measurements by sampling location, sample period, and plant community
structural type.
Plant Community Structural Type
Sampling Month Herbaceous Shrub Tree Total
June 715 747 71 1533
FA-104 478 524 41 1043
FA-128 237 223 30 490
July 1016 1011 8 2035
FA-104 285 309 0 594
FA-115 425 254 0 679
FA-128 306 448 8 762
September 12 22 0 34
FA-128 12 22 0 34
Total 1743 1779 79 3602
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 70 February 2014 Draft
10. FIGURES
Figure 4.3-1. Cottonwood (Populus) life history stages: seed dispersal and germination, sapling to tree establishment. Cottonwood typically germinates on newly created
bare mineral soils associate with lateral active channel margins and gravel bars. Note proximity of summer baseflow and floodplain water table (Braatne et al. 1996).
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 71 February 2014 Draft
Figure 4.3-2. The riparian “Recruitment Box Model” describing seasonal flow pattern, associated river stage (elevation),
and flow ramping necessary for successful cottonwood and willow seedling establishment (from Amlin and Rood 2002;
Rood et al. 2005).
Stage hydrograph and seed release timing will vary by region, watershed, and plant species. Cottonwood species is Populus deltoides, willow
species is Salix exigua.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 72 February 2014 Draft
Figure 4.3-3. Susitna Project area meteorological station locations.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 73 February 2014 Draft
Figure 4.4-1. Balsam poplar tree ice-scar. Floodplain located immediately above Three Rivers Confluence.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 74 February 2014 Draft
Figure 4.4-2. Balsam poplar forest tree ice-scars. Floodplain located immediately above Three Rivers Confluence.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 75 February 2014 Draft
Figure 4.4-3. Floodplain ice deposited gravel piles. Floodplain in braided reach below Three Rivers Confluence.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 76 February 2014 Draft
Figure 4.4-4. Tree ice scar wedge (Picea glauca, white spruce).
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 77 February 2014 Draft
Figure 4.6-1. Riverine hydrologic landscape (Winter 2001).
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 78 February 2014 Draft
Figure 4.6-2. (A) Transect profile view of typical monitoring well and stage recorder locations looking down river. (B)
Gold Creek Gauge Station, Susitna River April through September 2005-2009.
Water
Table Alder WillowWillowAlder WillowBalsam PoplarWhite Spruce/ Paper BirchPoplar/Alder White Spruce Paper BirchWells, Soil Temperature, Soil Moisture
Stage Recorder
Stage
Recorder
Stage
Recorder
Flood Levels
Fluctuating
Water Table
Regional
Groundwater
Gradient and
Fluctuations
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 79 February 2014 Draft
Figure 5.2-1. Riparian Process Domains on the Middle River with locations of associated Riparian IFS Focus Areas.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 80 February 2014 Draft
Figure 5.3-1. Location of four seed release sites surveyed in 2013 on the Susitna River.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 81 February 2014 Draft
Figure 5.3-2. Seed Dispersal Study Site at PRM 47: Deshka Landing
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 82 February 2014 Draft
Figure 5.3-3. Seed Dispersal Study Site at PRM 88: Parks Highway Bridge.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 83 February 2014 Draft
Figure 5.3-4. Seed Dispersal Study Site at PRM 102: Talkeetna
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 84 February 2014 Draft
Figure 5.3-5. Seed Dispersal Study Site at PRM 142: Indian River
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 85 February 2014 Draft
Figure 5.3-6. Daily air temperatures used for modeling at four sites.
PRM 47 (Deshka Landing) and PRM 88 (Parks Highway Bridge) June and July data is from HOBO temperature sensors, with additional
temperatures estimated based on correlation with Talkeetna Airport. PRM 102 (Talkeetna) and PRM 142 (Indian River) temperatures from AEA
project gauges.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 86 February 2014 Draft
Figure 5.3-7. Peak seed release period in 2013 for Populus balsamifera at PRM 47 (Deshka Landing) and PRM 88 (Parks
Highway Bridge) with discharge from the USGS Sunshine gauge (PRM 88).
Figure 5.3-8. Peak seed release period in 2013 for Populus balsamifera at PRM 102 (Talkeetna) and PRM 142 (Indian
River) with discharge from the USGS Gold Creek gauge.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 87 February 2014 Draft
Figure 5.3-9. Seedling Establishment Study Transect Locations at FA104.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 88 February 2014 Draft
Figure 5.3-10. Seedling Establishment Study Transect Locations at FA113.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 89 February 2014 Draft
Figure 5.3-11. Seedling Establishment Study Transect Locations at FA128.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 90 February 2014 Draft
Figure 5.3-12. Seedling Establishment Study Transect Locations at FA138.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 91 February 2014 Draft
Figure 5.3-13. Seedling Establishment Study Transect Locations at FA144.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 92 February 2014 Draft
Figure 5.3-14. Year 1 poplar seedling survival by transect between August and September sampling periods.
Figure 5.3-15. Year 1 willow seedling survival by transect between August and September sampling periods.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 93 February 2014 Draft
Figure 5.3-16. Year 1 poplar seedling survival plotted by geomorphic position.
Figure 5.3-17. Year 1 willow seedling survival plotted by geomorphic position.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 94 February 2014 Draft
Figure 5.3-18. Discharge at Gold Creek and rainfall observed at FA-104 and FA-128 during the 2013 seedling
establishment sampling period.
Figure 5.3-19. Stem length versus root length of first year poplar seedlings along Transect FA-104 STR1.
Note: Distances are meters from the end of the transect closest to the main channel.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 95 February 2014 Draft
(a) Poplar Seedling Survival
(b) Willow Seedling Survival
(c) Surface and cobble elevations
Figure 5.3-20. Seedling survival between August and September sampling efforts and elevation of surface and
cobble/gravel armoring (c) at FA113 STR5.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 96 February 2014 Draft
a) Poplar Seedling Survival
b) Willow Seedling Survival
c) Surface and cobble elevations
Figure 5.3-21. Seedling survival between August and September sampling efforts and elevation of surface and
cobble/gravel armoring (c) at a representative transect FA128 STR4.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 97 February 2014 Draft
a) Poplar seedling survival
b) Willow seedling survival
c) Surface and cobble elevation
Figure 5.3-22. Seedling survival between August and September sampling efforts and elevation of surface and
cobble/gravel armoring (c) at a representative transect FA144 STR4.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 98 February 2014 Draft
Figure 5.3-23. White spruce establishment transect locations and dendrology plots in FA-104.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 99 February 2014 Draft
Figure 5.3-24. White spruce establishment transect locations and dendrology plots in FA-113.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 100 February 2014 Draft
Figure 5.3-25. White spruce establishment transect locations and dendrology plots in FA-115.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 101 February 2014 Draft
Figure 5.3-26. White spruce establishment transect locations and dendrology plots near in FA-128.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 102 February 2014 Draft
Figure 5.3-27. White spruce establishment transect locations and dendrology plots near PRM 112 and 135.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 103 February 2014 Draft
Figure 5.3-28. Total number of seedling spruce trees per hectare along each island transect.
Figure 5.3-29. Total number of spruce trees per hectare along each island transect.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 104 February 2014 Draft
Figure 5.3-30. Total number of snag spruce trees per hectare along each island transect.
Figure 5.3-31. Spruce density and basal area by 30 meter quadrat increments observed along an eight-meter-wide belt
transect (Transect 1) on mid-channel island at PRM 115.6.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 105 February 2014 Draft
Figure 5.3-32. Spruce density and basal area by 30 meter quadrat increments observed along an eight-meter-wide belt
transect (Transect 1) on mid-channel island at PRM 128.1.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 106 February 2014 Draft
Figure 5.3-33. Example of soil core on island PRM 128.1 showing layers with high organic matter content overlain by
mineral soil.
Layers with
Increased Organic
Matter Mineral Layers
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 107 February 2014 Draft
Figure 5.3-34. Mean number of organic layers in upper 30 cm of soil profile and depth to cobble at randomly selected
locations across each island in the spruce seedling establishment study.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 108 February 2014 Draft
Figure 5.4-1. Top of ice scar above floodplain height (in feet) for scar observations between PRM 102.2 and 145.8.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 109 February 2014 Draft
Figure 5.4-2. Box and whisker plots of top of ice scar heights (ft) above the floodplain surface at three focus areas. Black
squares represent mean height.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 110 February 2014 Draft
Figure 5.4-3. Map of ice scar locations at a representative reach with frequent ice scars from PRM 132.1 to 135.0.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 111 February 2014 Draft
Figure 5.4-4. Map of ice scar locations at a representative reach with infrequent ice scars from PRM 116.9 to 121.3.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 112 February 2014 Draft
Figure 5.4-5. Map of ice scar locations and sampled ice scar wedges at FA-104.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 113 February 2014 Draft
Figure 5.5-1. Sediment core sampling locations and Dendrology Plots surveyed at FA-104.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 114 February 2014 Draft
Figure 5.5-2. Sediment core sampling locations and Dendrology Plots surveyed at FA-115.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 115 February 2014 Draft
Figure 5.6-1. Riparian GW/SW sampling locations at FA-104.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 116 February 2014 Draft
Figure 5.6-2. Riparian GW/SW sampling locations at FA-115.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 117 February 2014 Draft
Figure 5.6-3. Riparian GW/SW sampling locations at FA-128.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 118 February 2014 Draft
Figure 5.6-4. Distribution of Plant Isotope Samples by Plant Species at FA-104 and FA-128.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 119 February 2014 Draft
Figure 5.6-5. Sample data for sap velocity at two representative floodplain sampling locations at FA-104 between August
11, 2013 and August 27, 2013 (Julian day 223-237) for (A) P. glauca and (B) B. papyrifera and (C) vapor pressure deficit
during this sample period.
Note: Data at other sites and for remainder of season is in QC3 process and will be available for further analysis.
A
B
C
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 120 February 2014 Draft
Figure 5.6-6. Sap velocity for representative P. glauca and B. papyrifera trees at Station ESAFA104-4.
Note: Data at other trees and sites and for remainder of season is in QC3 process and will be available for analysis.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 121 February 2014 Draft
(a)
(b)
Figure 5.6-7. Seasonal Stomatal Conductance Distribution by Selected Species for (a) C. canadensis and (b) H. lanatum.
Boxes represent the upper and lower quartile of samples, whiskers of the boxes represents the IQR (interquartile range) or values in the data
that are furthers way from the median on either side of the box, and the mean is represented by a diamond.
n=145 n=259 n=2
n=92 n=164 n=5
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 122 February 2014 Draft
(a)
(b)
Figure 5.6-8. Seasonal Stomatal Conductance Distribution by Selected Species for (a) M. struthiopteris, and (b) V. edule.
Boxes represent the upper and lower quartile of samples, whiskers of the boxes represents the IQR (interquartile range) or values in the data
that are furthers way from the median on either side of the box, and the mean is represented by a diamond.
n=147 n=214 n=2
n=139 n=230 n=3
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 123 February 2014 Draft
(a) Alder/willow canopy type Leaf Area Index
\
(b) Poplar Canopy Leaf Area Index
(c) Spruce/Birch Canopy Leaf Area Index
Figure 5.6-9. Seasonal Leaf Area Index (LAI) by Canopy Types for (a) Alder/Willow, (b) Poplar, and (c) Spruce/Birch.
Boxes represent the upper and lower quartile of samples, whiskers of the boxes represents the IQR (interquartile range) or values in the data that are furthers way from the median on either side of
the box, and dots represent outliers to the dataset. Height is the vertical distance off the ground the measurement was taken (e.g., V1 = 150 cm from ground surface, V2 = 5 cm from ground surface).
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Page 124 February 2014 Draft
Figure 5.6-10. Soil Volumetric Water Content (θ) measured at FA-104 at depths ranging from 5 to 200 cm.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 February 2014 Draft
APPENDIX A: RIPARIAN FOCUS AREA SELECTION: RESPONSE TO
AGENCY COMMENTS REGARDING HERBACEOUS VEGETATION
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Appendix A – Page 1 February 2014 Draft
Riparian Focus Area Selection
Response to agency comments regarding Herbaceous Vegetation
Prepared by: Aaron Wells, Kevin Fetherston, and Kate Knox
Introduction
Aaron Wells (ABR, Inc. — Environmental Research & Services) and Kevin Fetherston,
Kate Knox and Alice Shelly (R2 Resource Consultants) joined in a conference call on 21
February 2013 with Bob Henszey, U.S. Fish and Wildlife Service (USFWS), and Chiska Derr,
National Oceanic and Atmospheric Administration (NOAA), to discuss final Riparian IFS
vegetation sampling approach, including focus area (FA) selection in the Middle River and 2013
Lower River riparian vegetation sampling. During the meeting ABR and R2 described the
methods for classifying the Riparian Process Domains (RPDs), and for mapping vegetation along
the Middle River using both Integrated Terrain Unit (ITU) mapping and vegetation transects.
The results of the classification and mapping were presented and discussion centered on the
selection of FAs and the degree which the selected FAs were representative of each of the RPDs.
During which both USFWS and NOAA generally agreed with the approach to classifying the
Middle River and FAs selection (Figure 1); however, the meeting adjourned with USFWS and
NOAA agreeing to hold a conference call to discuss the focus area selection strategy and provide
a formal response, including any additional concerns. In an email response dated 22 February
2013 USFWS and NOAA raised concerns about the adequacy of the riparian FAs in representing
the herbaceous vegetation along the Middle River. This technical brief was prepared in response
to these concerns.
Methods
The vegetation transects and Integrated Terrain Unit vegetation mapping were used to
determine the adequacy of herbaceous vegetation sampling in the Middle River FAs. The total
length of transects typed as the Level I vegetation class “herbaceous” were summed by RPD and
FA to determine the RPDs that feature a relatively large portion of the area as herbaceous
vegetation. These results were used to determine that the remaining mapping and analyses be
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Appendix A – Page 2 February 2014 Draft
restricted to RPD 3 as this is the longest and most complex RPD and has the greatest coverage of
herbaceous vegetation types (see RESULTS, below).
In the section of RPD 3 covered by ITU mapping (PRM 118–145), the area of Level IV
herbaceous vegetation types (Viereck et al. 1992) types was calculated across each RPD, and
within each of the proposed focus areas. These results were used to 1) determine how well the
focus areas represented the herbaceous vegetation within each RPD, and 2) to select additional
areas outside the focus areas (satellite areas) in which to sample herbaceous vegetation, thus
increasing sample plot number for herbaceous vegetation in RPDs where the Focus Areas may
be underrepresented.
For those areas of RPD 3 not covered by the ITU mapping, the portions of the vegetation
transects classified as the Level I Viereck et al. (1992) vegetation class “herbaceous” were
reclassified at the Level II Viereck et al. (1992) level (e.g., Forb Herbaceous, Graminoid
Herbaceous). The lengths of the transect segments mapped as a Level II herbaceous class were
aggregated by RPD and respective FA. The results were used to determine the
representativeness of the herbaceous vegetation in each FA relative to the RPD and to select
additional satellite sampling areas outside of the FAs if necessary.
Results and discussion
RPD 3 (4,138 m) featured the greatest cumulative distance of vegetation transects classified
as herbaceous (Figure 2). In RPD 3, Gold Creek (235 m, 6 percent of the total), Lane Creek
(183 m, 4 percent), and Skull Creek/Slough 8a (21 m, 1 percent) were the only FAs featuring
herbaceous vegetation. Given the low abundance of herbaceous vegetation in the RPD3 FAs
relative to the total abundance across the entire FA we further assessed the herbaceous vegetation
in RPD 3 (see below). RPD 4 (2,198 m) featured the second highest cumulative distance of
vegetation transects classified as herbaceous. In RPD4, Whiskers Slough featured a cumulative
length of 770 m (35 percent of the total) of herbaceous vegetation. Given the high abundance of
herbaceous vegetation in the Whiskers Slough FA relative to the total abundance across the
entire focus area we conclude that the herbaceous vegetation in Whiskers Slough adequate
represents RPD4.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Appendix A – Page 3 February 2014 Draft
The current extent of ITU mapping falls entirely within RPD3. Four Level IV vegetation
classes were mapped in this section of river in 2012 (Figure 2), including Ferns (56 acres), large
umbel (30), wet forb meadow (27), and bluejoint meadow (4). Three FAs were covered by the
ITU mapping, including FA-141 (Indian River), FA-138 (Gold Creek), and FA-128 (Skull
Creek). Herbaceous vegetation was not mapped at FA-141 and FA-128 (Figure 3). Three Level
IV herbaceous vegetation types were mapped at FA-138, including Ferns (8 acres), Large Umbel
(6), and Wet Forb Meadow (10). In areas of RPD3 covered by ITU mapping, the low coverage
of herbaceous vegetation types in several of the FAs suggests that FA-138 (Gold Creek) be
included as a riparian focus area in RPD 3. Additionally, several satellite areas where
herbaceous vegetation is abundant, including between PRM 112–113, 125–127, and 132–133,
will be incorporated into the 2013 sampling scheme.
In those areas of RPD 3 not currently covered by ITU mapping, including downstream of
PRM 118 and upstream of PRM 145, a total of 2,266 m were mapped as Level II herbaceous. Of
the total length, 1,196 m (53 percent of the total) were mapped as Forb Herbaceous, while 1,070
m (47 percent) were mapped as Graminoid Herbaceous (Figure 4). No herbaceous vegetation
types were mapped at FA-144 (Side Channel 21). A total of 184 m of Level II herbaceous types
were mapped at FA-115 (Lane Creek), including both Forb Herbaceous (114 m, 62 percent of
the total) and Graminoid Herbaceous (70 m, 38 percent). Hence, the herbaceous vegetation at
FA-115 featured a similar proportion of Level II vegetation classes and thus adequately
represents RPD 3 in areas not currently covered by ITU mapping.
Literature Cited
Viereck, L.A., C.T. Dyrness, A.R. Batten, and K.J. Wenzlick. 1992. The Alaska Vegetation
Classification. Pacific Northwest Research Station, U.S. Forest Service, Portland, OR. Gen.
Tech. Rep. PNW-GTR-286. 278 pp.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Appendix A – Page 4 February 2014 Draft
Figure 1. Middle River Riparian Process Domains and Focus Areas.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Appendix A – Page 5 February 2014 Draft
Figure 2. Length of transects typed as herbaceous vegetation within Riparian Process Domains 1-4 compared with herbaceous vegetation typed along transects within
the Focus Areas associated with each RPD. Lengths are in meters.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Appendix A – Page 6 February 2014 Draft
Figure 3. Area (ac) of Herbaceous AVC Level II Cover Types in each of three Focus Areas relative to portion of RPD3 with completed Integrated Terrain Unit
Mapping.
INITIAL STUDY REPORT RIPARIAN INSTREAM FLOW STUDY (8.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Appendix A – Page 7 February 2014 Draft
Figure 4. Sum of transect lengths (in meters) by cover type for Herbaceous AVC Level II for the part of RPD3 and Focus Areas without completed Integrated Terrain
Unit Mapping.