Loading...
HomeMy WebLinkAboutProbable max flood study section 16.5 2014Alaska Resources Library & Information Services Susitna-Watana Hydroelectric Project Document ARLIS Uniform Cover Page Title: Probable maximum flood (PMF) study, Study plan Section 16.5 : Initial study report SuWa 207 Author(s) – Personal: Author(s) – Corporate: Prepared by MWH AEA-identified category, if specified: Draft initial study report AEA-identified series, if specified: Series (ARLIS-assigned report number): Susitna-Watana Hydroelectric Project document number 207 Existing numbers on document: Published by: [Anchorage : Alaska Energy Authority, 2014] Date published: February 2014 Published for: Alaska Energy Authority Date or date range of report: Volume and/or Part numbers: Study plan Section 16.5 Final or Draft status, as indicated: Draft Document type: Pagination: v, 41 p. Related work(s): Pages added/changed by ARLIS: Notes: All reports in the Susitna-Watana Hydroelectric Project Document series include an ARLIS- produced cover page and an ARLIS-assigned number for uniformity and citability. All reports are posted online at http://www.arlis.org/resources/susitna-watana/ Susitna-Watana Hydroelectric Project (FERC No. 14241) Probable Maximum Flood (PMF) Study Study Plan Section 16.5 Initial Study Report Prepared for Alaska Energy Authority Prepared by MWH February 2014 Draft INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page i February 2014 Draft TABLE OF CONTENTS Executive Summary ...................................................................................................................... v 1. Introduction ....................................................................................................................... 1 2. Study Objectives................................................................................................................ 1 3. Study Area ......................................................................................................................... 1 4. Methods and Variances .................................................................................................... 2 4.1. Board of Consultants Review ........................................................................... 2 4.1.1. Variances......................................................................................... 2 4.2. Data Acquisition ............................................................................................... 2 4.2.1. Variances......................................................................................... 3 4.3. Historical Data Analysis ................................................................................... 3 4.3.1. Variances......................................................................................... 4 4.4. Review of Previous PMF Study Report ............................................................ 4 4.4.1. Variances......................................................................................... 4 4.5. Field Visit.......................................................................................................... 4 4.5.1. Variances......................................................................................... 5 4.6. Flood Hydrology Model Selection.................................................................... 5 4.6.1. Variances......................................................................................... 6 4.7. Flood Hydrology Model Initial Setup ............................................................... 6 4.7.1. Variances......................................................................................... 6 4.8. Flood Hydrology Model Calibration and Verification ..................................... 6 4.8.1. Variances......................................................................................... 6 4.9. Development of the Site-Specific PMP ............................................................ 7 4.9.1. Variances......................................................................................... 8 4.10. Coincident Conditions for the PMF .................................................................. 8 4.10.1. Variances......................................................................................... 8 4.11. Development of the PMF Inflow Hydrograph .................................................. 8 4.11.1. Variances......................................................................................... 8 4.12. Reservoir Routing of the PMF .......................................................................... 9 4.12.1. Variances......................................................................................... 9 4.13. Freeboard Analysis ........................................................................................... 9 4.13.1. Variances....................................................................................... 10 INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page ii February 2014 Draft 4.14. Reporting......................................................................................................... 10 5. Results .............................................................................................................................. 10 5.1. Board of Consultants....................................................................................... 10 5.2. Field Visit........................................................................................................ 11 5.3. Basin Hydrologic Data .................................................................................... 11 5.4. Sub-Basin Definition ...................................................................................... 12 5.5. Historic Flood Records ................................................................................... 12 5.6. Seasonal Flood Distribution ............................................................................ 12 5.7. Snowpack Determination ................................................................................ 13 5.7.1. Snowpack Distribution.................................................................. 13 5.7.2. 100-Year Snowpack ...................................................................... 14 5.7.3. Probable Maximum Snowpack ..................................................... 14 5.8. Runoff Model Calibration Floods ................................................................... 15 5.9. Probable Maximum Precipitation ................................................................... 16 5.10. Review of Previous PMF Studies ................................................................... 18 6. Discussion......................................................................................................................... 18 7. Plans for 2014 .................................................................................................................. 19 8. Literature Cited .............................................................................................................. 19 9. Tables ............................................................................................................................... 20 10. Figures .............................................................................................................................. 30 LIST OF TABLES Table 5.3- 1. USGS Streamflow Gages in the Susitna Watershed ............................................... 20 Table 5.3- 2. Snow Course and SNOTEL Stations In or Near the Susitna Watershed ................ 21 Table 5.4- 1. Area in Elevation Bands to Watana Dam ................................................................ 22 Table 5.4- 2. Susitna Watershed Land Cover ............................................................................... 23 Table 5.5- 1. Recorded Peak Flows – Susitna River at Gold Creek – 59 Years of Record .......... 23 Table 5.5- 2. Recorded Peak Flows – Susitna River at Cantwell – 18 Years of Record .............. 24 Table 5.5- 3. Recorded Peak Flows – Susitna River near Denali – 28 Years of Record .............. 24 Table 5.5- 4. Recorded Peak Flows – Maclaren River near Paxson – 28 Years of Record .......... 24 INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page iii February 2014 Draft Table 5.6- 1. Maximum Daily Flows for Each Month for the USGS Gage at Gold Creek .......... 25 Table 5.6- 2. Monthly Distribution of Annual Peak Flows .......................................................... 25 Table 5.7.1- 1. Monthly Precipitation by Month and Sub-Basin .................................................. 26 Table 5.7.2- 1. 100-Year Snowpack at Snow Course Stations ..................................................... 26 Table 5.7.2- 2. 100-Year All-Season Snowpack SWE ................................................................. 27 Table 5.7.3- 1. Probable Maximum Snowpack SWE ................................................................... 28 Table 5.9- 1. Short List of Storms................................................................................................. 29 Table 5.10- 1. Harza-Ebasco PMF Snowpack Estimate ............................................................... 29 LIST OF FIGURES Figure 5.2-1. Susitna River near Deadman Creek on May 29, 2013 ........................................... 30 Figure 5.2-2. Susitna River near the Denali Highway Crossing on May 29, 2013 ...................... 30 Figure 5.3- 1. Susitna Watershed Boundary and USGS Gage Locations ..................................... 31 Figure 5.3- 2. Location of Snow Course and SNOTEL Stations .................................................. 32 Figure 5.4- 1. Susitna Watershed Sub-Basins ............................................................................... 33 Figure 5.4- 2. Susitna Watershed Elevation Bands ....................................................................... 34 Figure 5.4- 3. Susitna Watershed Land Cover .............................................................................. 35 Figure 5.6- 1. Historic Flow Frequency at the USGS Gold Creek Gage ...................................... 36 Figure 5.6- 2. Watana Reservoir Simulated Elevations ................................................................ 36 Figure 5.7.1- 1. Average October through April Precipitation ..................................................... 37 Figure 5.8- 1. Recorded Flows at USGS Streamflow Gaging stations for June 1971 .................. 38 Figure 5.9- 1. SPAS Storm Analysis Results for the August 1967 Storm .................................... 39 Figure 5.9- 2. Rainfall Center Locations for the Short List Storms .............................................. 40 Figure 5.9- 3. Example of a Trajectory Model Analysis .............................................................. 41 INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page iv February 2014 Draft LIST OF ACRONYMS, ABBREVIATIONS, AND DEFINITIONS Abbreviation Definition AEA Alaska Energy Authority BOC Board of Consultants DAD Depth-Area-Duration FERC Federal Energy Regulatory Commission GLOF glacial lake outburst floods HMR hydrometeorological reports ILP Integrated Licensing Process ISR Initial Study Report PMF Probable Maximum Flood PMP Probable Maximum Precipitation Project Susitna-Watana Hydroelectric Project RSP Revised Study Plan SPAS Storm Precipitation Analysis System SSARR Streamflow Synthesis and Reservoir Routing SST Sea Surface Temperature SPD study plan determination WMO World Meteorological Organization INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page v February 2014 Draft EXECUTIVE SUMMARY Probable Maximum Flood (PMF) Study 16.5 Purpose The purpose of the study is to develop the inflow design flood (the PMF) for Watana Dam. The PMF inflow hydrograph will be routed through the reservoir and be used to size the spillway and determine the crest level of the dam to ensure flood safety of the dam. The PMF results from the Probable Maximum Precipitation (PMP), which is also developed as a part of this study, and other coincident conditions including snowmelt. Status Many aspects of the PMF study were completed during 2013 and the remaining tasks are in-progress. Key tasks to be completed during the second study season include unit hydrograph verification, seasonal PMP values as developed from the all-season PMP, and flood routing of the PMF hydrographs. Study Components The major study components include the following: (1) data acquisition of meteorological, hydrological, and snow data, (2) historical data analysis, (3) review of previous Susitna PMF studies, (4) a field visit, (5) study reviews by a Board of Consultants, (6) runoff model selection, (7) runoff model calibration and verification, (8) development of a site specific PMP, (9) development of snowpack and other conditions coincident with seasonal PMP storms, (10) reservoir routing of the PMF, (11) spillway sizing, (12) freeboard analysis, and (13) reporting. 2013 Variances There were no variances from the RSP that would limit the accuracy, effectiveness or utility of the PMP and PMF results. The most significant variance from the RSP was to increase the number of calibration and verification floods from the standard three to six floods. As the PMF study progressed, it became clear that floods resulting from two different dominant sources (rainfall and snowmelt) must be considered. Choosing three floods of each type doubled the need for historic meteorological data development and flood calibration and verification, but ensured the accuracy of the ultimate controlling PMF hydrograph. Steps to Complete the Study As explained in the cover letter to this draft ISR, AEA’s plan for completing this study will be included in the final ISR filed with FERC on June 3, 2014. Highlighted Results and Achievements Extensive meteorological data acquisition and analysis has resulted in the development of nine candidate storms from which the all-season PMP and seasonal PMP values can be determined. Data acquisition and analysis has been completed for development of the 100-year seasonal snowpack values and probable maximum snowpack. A detailed flood runoff model was developed with calibration and verification nearing completion. INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 1 February 2014 Draft 1. INTRODUCTION On December 14, 2012, Alaska Energy Authority (AEA) filed with the Federal Energy Regulatory Commission (FERC or Commission) its Revised Study Plan (RSP), which included 58 individual study plans (AEA 2012). Section 16.5 of the RSP described the Probable Maximum Flood (PMF) Study. This study focuses on developing a site-specific Probable Maximum Precipitation (PMP) and modeling the PMF. RSP 16.5 provided goals, objectives, and proposed methods for data collection regarding PMF. On February 1, 2013, FERC staff issued its study plan determination (February 1 SPD) for 44 of the 58 studies, approving 31 studies as filed and 13 with modifications. RSP Section 16.5 was one of the 31 studies approved with no modifications. Following the first study season, FERC’s regulations for the Integrated Licensing Process (ILP) require AEA to “prepare and file with the Commission an initial study report describing its overall progress in implementing the study plan and schedule and the data collected, including an explanation of any variance from the study plan and schedule.” (18 CFR 5.15(c)(1)) This Initial Study Report (ISR) on the Probable Maximum Flood (PMF) Study has been prepared in accordance with FERC’s ILP regulations and details AEA’s status in implementing the study, as set forth in the FERC-approved RSP (referred to herein as the “Study Plan”). 2. STUDY OBJECTIVES The general goals and objectives of the PMF study are as follows: • Develop a site-specific PMP to be used for the derivation of the PMF including both a temporal and spatial distribution of rainfall; • Model the runoff through the project drainage basin to produce the PMF inflow, including snowmelt considerations for the Project reservoir; • Route the PMF inflow through the Project to obtain the PMF outflow and maximum flood elevation at the dam; • Determine the required outlet capacity to safely route the PMF through the reservoir; • Determine the freeboard allowance; and • Use the Board of Consultants (BOC) for technical review during development and performance of the site-specific studies. 3. STUDY AREA As established by RSP Section 16.5.3, the study area is the entire watershed tributary to the Watana Dam site, plus the additional drainage area between Watana Dam and the USGS gaging INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 2 February 2014 Draft station at Gold Creek. The watershed drainage area is 5,180 square miles at the Watana Dam site and 6,160 square miles at the Gold Creek USGS gage. 4. METHODS AND VARIANCES The following sections describe the study methods and major tasks necessary to develop the PMP and PMF for Watana Dam, including variances from the original study plan. 4.1. Board of Consultants Review During the 2013 study season, AEA implemented the methods for the Board of Consultants (BOC) as set forth in RSP Section 16.5.4.1, with no variances. A BOC has been established for technical review of many aspects of the dam design. The BOC review of the studies described herein has been primarily focused on the development of the site- specific PMP but has also included other aspects of the PMF study. The BOC has met and will continue to meet and review design progress at appropriate intervals and, when appropriate, can co-opt specialists for particular topic review. The PMP and PMF study methods and tasks described herein have been the subject of review by the BOC. 4.1.1. Variances There are no variances to the BOC section of this study. 4.2. Data Acquisition During the 2013 study season, AEA implemented the methods for data acquisition as set forth in RSP Section 16.5.4.2, with the exception of variances explained below in Section 4.2.1. A variety of historical recorded meteorological and hydrologic data are necessary to develop the PMP and PMF. Data acquisition began at the earliest possible time as it was anticipated that some data (e.g., streamflow data on a time increment less than daily) could take months to retrieve. Previous PMP and storm analysis work in the region were reviewed to identify storm events, available rainfall data and techniques applicable the basin. PMP-type storm events which have occurred in a region that were considered transpositionable to the basin were identified in the storm search. A comprehensive list of significant storm events and the characteristics of the PMP type storm(s) relevant to the basin was constructed. Storms identified included storms used in previous PMP and hydrologic studies in the region. Nine storms have been identified and are the short list storms. The resulting list of storms was used to derive the PMP values for the basin for the all season PMP and the seasonally adjusted PMP. Data was acquired to develop meteorological time series for use in rain on snow PMF modeling. Information from six floods and the associated meteorological data was used in the runoff model calibration efforts. Daily and hourly time series were developed for meteorological parameters INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 3 February 2014 Draft (i.e. temperature, dew point, wind) required for snow melt modeling using data from surrounding weather stations (e.g. NWS COOP, RAWS, SNOTEL, and various other networks). Relevant watershed data was collected including the streamflow data, drainage area of sub- basins, the area within elevation bands for snowpack and snowmelt estimation, channel slopes, vegetation cover, lake area, and soil types. 4.2.1. Variances Archived USGS hourly streamflow records for selected floods were requested but not received. USGS daily streamflow records are available at all gages in the watershed for the period of record, and 15-minute flow data is available for the September 2012 flood. Due to the large area of the watershed and the significant snowmelt component of most floods, flood hydrographs occur over periods of 10 to 20 days, or even longer. Instantaneous annual maximum peak flows are also available. This amount of streamflow data is considered adequate to fully meet the hydrograph calibration and verification objectives of the PMF study. 4.3. Historical Data Analysis During the 2013 study season, AEA implemented the methods for the analysis of historical data as set forth in RSP Section 16.5.4.3, with no variances. Historical data analysis forms the basis of the PMP and PMF analysis and consisted of the following.  Previous PMP and storm analysis work were reviewed. Significant rainfall storm events that were previously identified were noted along with supporting data and techniques used in PMP determination. Additionally, procedures used in other site-specific studies were identified that could be used for the Susitna-Watana Dam site-specific PMP study.  A search to identify the most significant rainfall storm events in and surrounding the basin was completed.  Storm rainfall analyses using the Storm Precipitation Analysis System (SPAS) were completed for the nine identified extreme rainfall storm events.  A maximum Sea Surface Temperature (SST) climatology was developed for storm atmospheric moisture source regions over the Gulf of Alaska and northern Pacific Ocean. This climatology is the mean SST plus 2-sigma (2 standard deviations) and provides maximum SSTs for the storm maximization and transpositioning procedures.  Historic peak flows were summarized for selection of major flood events for model calibration and verification.  Flood frequency analyses were performed for up to at least the 100-year flood from historical peak flow data.  Antecedent watershed conditions prior to the PMP were developed.  The 100-year snowpack and snow water equivalent was determined for various elevation bands. INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 4 February 2014 Draft  The 100-year and probable maximum snowpack was developed based on October through April average precipitation. 4.3.1. Variances There are no variances to the historical data analysis section of this study. 4.4. Review of Previous PMF Study Report During the 2013 study season, AEA implemented the methods for review of the previous PMF study report as set forth in RSP Section 16.5.4.4, with the exception of variances explained below in Section 4.4.1. In support of the previous design and licensing effort for the APA Susitna Hydroelectric Project, two PMF studies were performed (Acres 1982, and Harza-Ebasco 1984). These PMF studies included developing a site-specific PMP and used generally accepted methods at the time. It is notable that although many new data have become available in the 30-year interim since the previous PMF study, all of the five largest floods of record at the Gold Creek USGS gaging station were available for calibration and verification studies in 1982 (subject to change by the June 2013 flood). Although few calculations and model input data, and no output are available, the two PMF studies do contain useful information regarding final results and conclusions of the analysis, including numerous tables and figures. The two PMF study reports were thoroughly reviewed to gain applicable insights to be used in the current PMF study. 4.4.1. Variances Subsequent to the Commission’s February 1 SPD, the 1984 Susitna PMF study became available. It was included in the review of previous PMF studies in the same manner as the 1982 Susitna PMF study so that a comprehensive background of PMF studies for the Susitna could be used to inform and verify the current study approach As a historical note, two of the largest seven floods of record at the USGS streamflow gaging station at Gold Creek have occurred (September 2012 and June 2013) since filing of the PMF study plan, although peak flow rates are preliminary and subject to change by the USGS. The June 2013 flood is not used in this study because it occurred after selection and meteorological data analysis began of the storms associated with the floods used for runoff model calibration and verification. 4.5. Field Visit During the 2013 study season, AEA implemented the methods for the field season as set forth in RSP Section 16.5.4.5, with no variances. In conformance with FERC’s recommendations for PMF studies (FERC 2001), AEA conducted two field visits during the 2012 and 2013 study seasons. These occurred on September 27, 2012 and May 29, 2013. The site flyover on May 29, 2013 with the BOC included representatives from the study team. The site flyover of September 27, 2012 was specifically for the study team participants. The site visits were undertaken to observe significant topographical variations within and adjacent to the basin. Observations made during the field visits were oriented toward the following aspects: INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 5 February 2014 Draft  Manning’s “n” and general hydrologic and hydraulic characteristics of river channels;  Special features within the drainage basin such as marshes, lakes, and closed basins that may delay or reduce runoff;  Constrictions such as bridge abutments that may influence flood routing characteristics, although none were observed;  Areal extent of snow cover;  Large natural constrictions that could act as hydraulic control structures, but none were observed; and  Areas that could result in locally different infiltration rates, including rock exposures, dense forest, or high altitude meadows. 4.5.1. Variances There are no variances to the field visit section of this study. 4.6. Flood Hydrology Model Selection During the 2013 study season, AEA implemented the methods for flood hydrology model selection as set forth in RSP Section 16.5.4.6, with no variances. At least three flood hydrology models are available, and a key task was to select which to use to develop the PMF. These models include:  Streamflow Synthesis and Reservoir Routing (SSARR). This model was developed by the U.S. Army Corps of Engineers (USACE), North Pacific Division. The SSARR model was used for the 1982 Susitna PMF study. In addition to its use by the USACE, the SSARR model was used occasionally by consultants for flood simulation on major watersheds, particularly in the Pacific Northwest. The SSARR model is no longer in general use. The latest version of SSARR was modified in 1991 to run on IBM-compatible personal computers. The USACE has noted that there will be no further program updates or modifications to the SSARR files by the USACE, and no user support is available.  Flood Hydrograph Package (HEC-1). This model was developed by the Hydrologic Engineering Center (HEC) of the USACE and was (possibly still is) the most widely used model in PMF studies. HEC-1 is one of the two rainfall-runoff models recommended for PMF studies (FERC 2001). Compared to other models, HEC-1 has the advantage of including the recommended energy budget snowmelt method as well as fully documented equations for calculating snowmelt in the model.  Hydrologic Modeling System (HEC-HMS). This model was also developed by the HEC and is the Windows-based successor to HEC-1. HEC-HMS contains many of the same methods as HEC-1 and is the other model recommended for PMF studies (FERC 2001). Snowmelt in the HEC-HMS model is based on a method that uses temperature data only. Flood hydrology model selection was reviewed with the BOC during the initial BOC meeting on November 2, 2012. With BOC input from that review, AEA has selected the HEC-1 Flood Hydrograph Package as the rainfall-runoff model for developing the PMF. INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 6 February 2014 Draft 4.6.1. Variances There are no variances to the flood hydrology model selection section of this study. 4.7. Flood Hydrology Model Initial Setup During the 2013 study season, AEA implemented the methods for the initial setup of the flood hydrology model as set forth in RSP Section 16.5.4.7, with no variances. The flood hydrology computer model initial setup includes sub-basin delineation, areas in elevation bands for use in snowmelt calculations, lake areas, areas in various soil groups, coincident base flow, and initial estimates of infiltration rates. Sub-basin delineation was aligned with USGS stream-gaging station locations whenever possible to facilitate model calibration and verification. River channel geometry was checked for areas that may warrant special consideration for storage-outflow routing. Topographic mapping was developed using ArcGIS software. 4.7.1. Variances There are no variances to the flood hydrology model initial setup section of this study. 4.8. Flood Hydrology Model Calibration and Verification During the 2013 study season, AEA implemented the methods for flood hydrology model calibration and verification as set forth in RSP Section 16.5.4.8, with the exception of variances explained below in Section 4.8.1. This task includes calibration and verification of the sub-basin unit hydrographs to the extent that available recorded streamflow and meteorological data allow. Calibration provides the important adjustments to hydrograph parameters that are initially estimated from standard equations or based on experience in similar watersheds. Two of the largest floods on record were planned to be selected for calibration, with a third large historical flood used for verification. However, as work proceeded in reviewing floods, three floods were chosen each for rainfall and snowmelt flood events because it was not clear which flood type would be the dominant and critical condition for the PMF. More storms would also be available if further calibration/validation is required. The calibration points at the outlets of the sub-basins coincide with USGS stream- gaging stations to the extent possible. The selection of storm periods to use in model calibration and verification included the availability of data at multiple stream-gaging stations. Activities under this task would also include estimating ungaged local runoff as necessary, base flow separation, and a final estimate of infiltration loss rates. 4.8.1. Variances The calibration and verification of hydrograph parameters normally involves the collection of meteorological and flow data for three flood periods. Analysis of flood records as the PMF study proceeded revealed that there have been two fundamentally different and seasonally separated flood generating scenarios, one resulting primarily from rainfall, the other primarily from snowmelt. It could not be determined in advance which of these flood generating scenarios INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 7 February 2014 Draft would ultimately be the critical condition for the PMF. Therefore, three floods of each type (total of six) were selected for calibration and verification. This resulted in an initially unanticipated increase in data acquisition and calibration effort, although it was considered to be necessary for a reliable determination of the PMF. 4.9. Development of the Site-Specific PMP During the 2013 study season, AEA implemented the methods for flood hydrology model calibration and verification as set forth in RSP Section 16.5.4.8, with the exception of variances explained below in Section 4.9.1. The applicable available National Weather Service (formerly the U.S. Weather Bureau) PMP guidance document is Probable Maximum Precipitation and Rainfall-Frequency Data for Alaska, Technical Paper No. 47 (Miller 1963). Technical Paper No. 47 is applicable to areas up to 400 square miles and durations up to 24 hours. Because the drainage area at the Watana Dam site is 5,180 square miles and current standards call for the PMP to have a duration of at least 72 hours, development of a site-specific PMP is necessary. The existing PMP studies are being used to make comparisons to the 1982 Susitna site-specific PMP and the Technical Paper No. 47 PMP at the highest-intensity central 400-square-mile area and 24-hour duration of the new site- specific PMP. Development of the site-specific PMP for the watershed tributary to the proposed Watana Dam site required a substantially greater effort than is necessary for most other dams in the USA because of new storm analyses, sparse data availability and cool season considerations. The site-specific PMP study follows many of the methods (e.g., a storm-based approach) used to develop the current National Weather Service PMP hydrometeorological reports (HMR). The basic techniques for storm maximization and transposition are well-established. An additional 30 years of data and more advanced models and recent adjustments to methods are now available for development of site-specific PMP (e.g. radar aided storm analyses, quantification of orographic affects). Results include both a temporal and spatial distribution of the PMP for durations appropriate to most accurately model the PMF. No predetermined maximum storm sequence length is set so that the critical PMP sequence could be 96 hours or more. Long duration, high volume events are among the candidate PMF cases evaluated to determine if they constitute the critical storm event for the determination of the PMF maximum reservoir elevation. In addition, guidance for alternative centerings of the PMP design storm are determined based on the patterns of the actual storm events used to derive the PMP values. NEXRAD data are used when available (generally after 1995) in all storm analyses. A consultant with extensive experience in developing site-specific PMP was retained to perform this task. The initial storm search included all twelve months of the year, so the months that are potentially PMP drivers will naturally result from this process. Based on an analysis of historic flow frequency, peak annual flood data, and anticipated seasonal reservoir levels, the PMP development is expected to be focused on the months of May through October. The site-specific PMP task also includes development of the 100-year precipitation temporal and spatial distribution during a season coincident with the probable maximum snowpack. INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 8 February 2014 Draft 4.9.1. Variances While the development of the site-specific PMP is well underway, it was not completed in study year 2013. At the time the RSP was prepared, it was contemplated the development of the PMP could be fully accomplished in the first study year, however due to the complexity of the meteorology to capture both snowmelt and rainfall, and the need to accommodate the BOC schedules for meetings leading into 2014, the PMP work was not finalized, but will be finalized in 2014.. This will allow the study to meet the study objectives by allowing the BOC a full review of the PMP work. 4.10. Coincident Conditions for the PMF Developing coincident conditions includes the 100-year snowpack, the probable maximum snowpack, necessary temperature, dew point, and wind speed sequences, and other data for energy budget method as necessary. The 100-year precipitation is also being developed, because one of the potential combinations of coincident conditions that can result in the PMF is the probable maximum snowpack combined with the seasonally appropriate 100-year precipitation. A determination of the maximum reservoir level during the 50-year flood may also be required, as this may become the starting reservoir elevation for spillway operation. 4.10.1. Variances While the development of the coincident conditions for the PMF work efforts were mostly accomplished in 2013, the full effort was not completed in study year 2013. At time the RSP was prepared, it was contemplated the site-specific PMP and PMF study could be completed in 2013, however due to the complexity of the hydrology to capture both snowmelt and rainfall events, and the need to accommodate the BOC schedules for meetings leading into 2014, the PMF work was not finalized, but will be finalized in 2014. This will allow the study to be ensure it meets the study objectives by allowing the BOC a full review of the PMP work. 4.11. Development of the PMF Inflow Hydrograph The PMF is being developed at the proposed Watana Dam site by combining sub-area runoff and performing channel and reservoir routings for various cases and months. The energy budget snowmelt method is being used. Routing of the PMF through the reservoir may account for use of the fixed-cone outlet valves for discharges up to the 50-year flood and use of the spillway only after the expected maximum level of the 50-year flood has been exceeded, but final flood operating procedures are not yet finalized. While the development of the PMF Inflow Hydrograph was initiated in 2013, work efforts will continue into 2014. This task also includes a sensitivity analysis to test the effects of variation in parameters with relatively high uncertainty that could potentially have more significant effects on the results. The PMF channel routing will use the selected flood hydrology model. 4.11.1. Variances As noted above, the full effort was not completed in study year 2013. At the time the RSP was prepared, it was contemplated the site-specific PMP and PMF study could be completed in 2013, INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 9 February 2014 Draft however due to the complexity of the hydrology to capture both snowmelt and rainfall events, and the need to accommodate the BOC schedules for meetings leading into 2014, the PMF work was not finalized, but will be finalized in 2014. This will allow the study to ensure it meets the study objectives by allowing the BOC a full review of the PMP work. 4.12. Reservoir Routing of the PMF Spillway capacity should be determined as part of the economical combination of spillway capacity and surcharge storage. Surcharge storage is defined as the storage between the normal maximum pool level (still water) and the maximum design flood water storage level. Determining the economical combination of surcharge storage/spillway capacity requires evaluation of the cost of increasing spillway capacity versus the cost of raising the dam height to provide the required freeboard (routed maximum flood level plus any required allowance for wind setup and wave run-up). Reservoir flood routing is used to determine the temporal and water level variation of the hydrograph as the flood passes through the reservoir. Increasing the spillway capacity will reduce the necessary surcharge storage (determined by flood routing), thereby lowering the required height of the dam. Alternatives analysis are being performed to optimize spillway capacity and flood surcharge. The PMF reservoir routing will use the selected flood hydrology model. As outlined in the RSP, this task was expected to be part of the PMF study that would all be accomplished in 2013, however this specific study component is being deferred to 2014. It is expected that the volume and distribution of potential future sedimentation in the reservoir will form a PMF routing sensitivity case. AEA is evaluating the potential for glacial lake outburst floods (GLOF). AEA will compare the potential for GLOF to the critical PMF inflow hydrograph and will route the GLOF to determine the peak reservoir level if the GLOF potentially forms the critical condition for spillway design. 4.12.1. Variances As noted above, the full effort was not completed in study year 2013. At time the RSP was prepared, it was contemplated the site-specific PMP and PMF study could be completed in 2013, however due to the complexity of the hydrology to capture both snowmelt and rainfall events, and the need to accommodate the BOC schedules for meetings leading into 2014, the PMF work was not finalized, but will be finalized in 2014. This will allow the study to meet the study objectives by allowing the BOC a full review of the PMP work. 4.13. Freeboard Analysis Freeboard provides a margin of safety against the potential for overtopping of dams. Freeboard and flood control storage are required to provide the capacity to store and/or route the design storm through the reservoir considering inflows, precipitation on the reservoir basin, and wind generated waves without hazardous overtopping of the dam. Although freeboard selection involves more than simply the PMF water level, the freeboard selection will be made as part of the subject study, based on wind setup, wave action, uncertainties in analytical procedures, and uncertainties in Project function in combination with the most critical pool elevation (USACE 1991). The freeboard determination will be based on site-specific conditions that can be INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 10 February 2014 Draft reasonably expected to occur simultaneously. Design criteria will be developed for logical combinations of reservoir levels/precipitation and wind conditions for freeboard determination. Wind setup and wave run-up will be determined with standard methods (USACE 1984 and USACE 2003). As outlined in the RSP, this task was expected to be part of the PMF study that would all be accomplished in 2013, however this specific study component is being deferred to 2014. Normal freeboard is defined as the difference in elevation between the top of the dam and the normal maximum pool elevation. Minimum freeboard is defined as the difference in pool elevation between the top of the dam and the maximum reservoir water surface that would result from routing the PMF through the reservoir. It is generally not necessary to prevent splashing or occasional overtopping of a dam by waves under extreme conditions particularly for a concrete dam. If studies demonstrate that the RCC dam can withstand wave overtopping without erosion of foundation or abutment material, then minimum (or no) freeboard will be selected for the PMF condition. In that case, only normal freeboard would be required. The study of freeboard will take into account unusual circumstances. 4.13.1. Variances As noted above, the full effort was not completed in study year 2013. At time the RSP was prepared, it was contemplated the site-specific PMP and PMF study could be completed in 2013, however due to the complexity of the hydrology to capture both snowmelt and rainfall events, and the need to accommodate the BOC schedules for meetings leading into 2014, the PMF work was not finalized, but will be finalized in 2014. This will allow the study to meet the study objectives by allowing the BOC a full review of the PMP work. 4.14. Reporting Two reports will be prepared, one covering the development of the site-specific PMP, the other an overall PMF report for all aspects of the PMF study, including a summary of the site-specific PMP. The PMF report will generally follow the outline suggested by FERC for PMF studies (FERC 2001). 5. RESULTS This section summarizes results completed to date. 5.1. Board of Consultants The BOC meetings to date with regards to the PMP and PMF are summarized as follows:  November 1-2, 2012, Bellevue, WA – This was the initial meeting of the BOC. The PMP presentation included a comprehensive overview of the site-specific PMP study process, and a preliminary graphic analysis of selected historic storms, sea surface temperatures, meteorological data, and storm tracks. PMF discussion focused on the availability of USGS streamflow gaging data, historic seasonal flows and annual peak flows, data contained in INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 11 February 2014 Draft previous Susitna PMF studies from the 1980s, PMF rainfall-runoff model selection, snowmelt method selection, seasonal limits of the PMF study, and a review of the PMF study plan.  March 7-8, 2013, Bellevue, WA – This BOC meeting focused on Susitna-Watana aspects other than the PMP and PMF. Only a very brief update on the PMP and PMF studies was presented.  April 3-4, 2013, Denver, CO – This meeting was exclusively a PMP and PMF workshop with only the PMP and PMF experts from the BOC attending. PMP topics covered included selection of the initial storm short list, initial historic storm analysis, the storm maximization process, the limits of storm transposition, the orographic transposition factor, and the meteorological time-series development process. PMF aspects discussed included sub-basin segmentation, data acquisition using GIS, the months of occurrence of annual peak flows, selection of floods for hydrograph parameter calibration and verification, and results of a reconstruction of the 1982 PMF.  May 29-30, 2013, Anchorage, AK – This meeting was primarily a site visit for the full BOC, but PMP and PMF updates were also included on May 30. On May 29, the PMP and PMF BOC experts and consultants conducted a watershed over-flight in a single-engine airplane. The PMP status update included a summary of work completed on storm analysis, meteorological data for the runoff model, storm maximization and development of the proportionality constant. The PMF update included a discussion of alternative methods for required snowpack development, seasonal watershed precipitation and mapping, snowpack data availability, and a runoff volume frequency analysis. 5.2. Field Visit A field visit is a recommended part of the PMF study (FERC 2001) and was performed on May 29, 2013 with the BOC. The PMP and PMF BOC experts and consultants conducted a watershed over-flight in a single-engine airplane, beginning and ending at Talkeetna airport. Numerous geo-referenced photographs were taken. All watershed observations were made from the air as no landings were made within the watershed area tributary to Watana Dam. The field visit occurred at an opportune time because a flood flow that equaled the maximum flow of record occurred at the Gold Creek USGS gaging station on June 2, 2013. On May 29, the day of the site visit, the high temperature was 83 degrees at Talkeetna. A colder than average spring was followed by a rapid warming that resulted in a snowmelt flood without significant concurrent rainfall. Figure 5.2-1 shows remnants of a river ice cover following the breakup. Figure 5.2-2 shows the Susitna River in the vicinity of the Denali Highway crossing with remaining snow cover on May 29, 2013. 5.3. Basin Hydrologic Data Table 5.3-1 lists the data availability at USGS streamflow gaging stations in or near the Susitna watershed. Figure 5.3-1 is a location map that shows the location of USGS gages and the Susitna River watershed boundaries to Watana Dam and to the most downstream USGS gaging station. INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 12 February 2014 Draft Determination of snowpack and the resulting snowmelt is a particularly important part of the PMF study. Figure 5.3-2 shows the locations of the snow course and SNOTEL stations in and near the Susitna River watershed. Table 5.3-2 provides the latitude-longitude location, elevation, and period of record for the snow course and SNOTEL stations. Data for the full period of record was gathered at all of the stations. 5.4. Sub-Basin Definition Figure 5.4-1 outlines the 29 sub-basins tributary to Watana Dam and the 5 additional sub-basins between Watana Dam and the USGS gaging station at Gold Creek, which is the downstream limit of the PMF study. Table 5.4-1 provides a summary of elevation-band area data for the 29 sub-basins tributary to Watana Dam. The watershed area in elevation bands is depicted on Figure 5.4-2. Figure 5.4-3 shows the type and distribution of watershed cover and Table 5.4-2 provides a data summary for the watershed cover types. Shrub and scrub is the dominant watershed cover type, totaling about 56% of the entire watershed. Forest covers about 18% of the watershed to the Gold Creek USGS gaging station. Barren land makes up about 15% of the watershed cover, while wetlands cover 3.9%, perennial snow/ice is 3.8% and open water covers 2.9% of the watershed. 5.5. Historic Flood Records For the four USGS gages upstream or near the proposed Watana Dam site, the ranked highest ten peak flows of record for the Susitna River at Gold Creek, Cantwell, near Denali, and for the Maclaren River near Paxson have been summarized in Tables 5.5-1 through Table 5.5-4, respectively. Floods for the same date at different stations have been highlighted in the same color. Floods with the largest recorded peaks at the most gages are favored for selection as flood hydrograph calibration and verification floods. As would be expected, there is some variation in the flood rankings from gage to gage, in part due to the period of record available for each gage. 5.6. Seasonal Flood Distribution The determination of a 100-year snowpack for every month of the year is unnecessary because of the highly seasonal nature of Susitna River flow. With 59 years of daily flow data available, the USGS streamflow gage at Gold Creek provides an excellent long-term record of the seasonality of Susitna River flow. Table 5.6-1 provides the maximum daily flow of record at Gold Creek for each month. During the coldest months of November through March, a daily flow of as much as 10,000 cfs has never been recorded, indicating that these five months can be eliminated as potentially maximum flood producing months. Table 5.6-2 presents a summary of the month of occurrence of the annual peak flow at each of the four USGS gages in or near the watershed tributary to the Watana Dam site. For the gaging stations nearest the Watana Dam site, Gold Creek and Cantwell, June is the month during which the annual maximum flows most frequently occur and the same is true at the Maclaren gage. The Denali gage is most heavily influenced by glacier melt and annual peak flows occur most INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 13 February 2014 Draft frequently at Denali during July or August. In 134 gage-years of daily flow data, an annual peak flow has never been recorded during the months of October through April. Additional flow frequency data at Gold Creek is provided on Figure 5.6-1, and simulated maximum and median monthly Watana reservoir elevations are shown on Figure 5.6-2. Because April is the month with the lowest reservoir elevations, and April flows exceed 10,000 cfs less than 1 percent of the time, April can be eliminated from further consideration as the critical PMF month for Watana Dam. Although October has never had an annual maximum flow, the reservoir levels would be higher and it was therefore retained for further consideration as a potentially critical month for the PMF. 5.7. Snowpack Determination 5.7.1. Snowpack Distribution Maximum snowpack distribution data was developed in proportion to the October through April average precipitation as has been previously suggested for the Yukon River (Weather Bureau 1966). GIS-based monthly precipitation was prepared using PRISM (Parameter-elevation Regressions on Independent Slopes Model) an analytical tool developed at Oregon State University that uses point data, a digital elevation model, and other spatial data sets to generate gridded estimates of monthly, yearly, and event-based climatic parameters, such as precipitation, temperature, and dew point. Figure 5.7.1-1 graphically depicts the October through April average precipitation for the drainage area above the Gold Creek USGS gaging station. This figure clearly shows the wide variation in precipitation with lower total precipitation in the southeast part of the watershed and higher precipitation in the northern and western portions of the watershed. Historic snowpack data at available SNOTEL and snow course stations can be used to develop the 100-year snowpack by season. The same ratio of the 100-year snowpack at a given snow course station (or stations) for a given month to the seasonal precipitation (Oct-April) is being used to develop the 100-year snowpack at all locations. Different ratios are used for different months. For example, if the 100-year SWE at a snow course station (or stations) for May was equal to 120 percent of the October through April average precipitation at the snow course station (or stations) as determined from GIS precipitation maps, then the 100-year SWE at all locations in the watershed for May would be equal to 120 percent of the Oct-Apr precipitation. Table 5.7.1-1 provides the monthly average precipitation for each sub-basin and for the annual and October through April totals. Also shown is the area-weighted average precipitation to Watana Dam and to each of the four USGS gaging stations. The months of maximum precipitation are July through September with April being the month with the minimum precipitation. The average October through April precipitation varies from a maximum of almost 20 inches for the West Fork Susitna River (sub-basin 6) to a minimum of 4.32 inches in the area tributary to Susitna Lake and Tyone Lake (sub-basin) 14. INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 14 February 2014 Draft 5.7.2. 100-Year Snowpack PMF combined events criteria call for using a 100-year snowpack coincident with the PMP appropriate for the same month. The 100-year snow water equivalent was developed at several stations based on monthly snowpack statistics and the following equation: SWE = M + KS where: SWE is the 100-year snow water equivalent (inches) M is the mean snow water equivalent for a month (inches) S is the standard deviation of the monthly snow water equivalent (inches) K is a factor corresponding to a 100-year return period and the calculated skew of the monthly snow water equivalent Table 5.7.2-1 presents the calculated 100-year snow water equivalent values on or about the first of the month from February through May. Also shown is the October through April average total precipitation at the snow course locations as obtained from PRISM data. The last column of this Table shows the ratio of the calculated May 1, 100-year SWE values to the October through April total average precipitation. These are the key values used to distribute the 100- year snowpack over the watershed. The last column ratios in Table 5.7.2-1 for snow courses in areas tributary to Watana Dam range from 1.51 to 1.94 and average 1.68. The data for the snow courses highlighted in red, which are all outside the area tributary to Watana Dam, are all outside the 1.51 to 1.94 range and have therefore been eliminated from further consideration. Therefore, the tributary area average factor of 1.68 times the average October through April total precipitation was selected and was used to develop the 100-year May and June snowpacks. Due to the potential for cold weather to persist from April up to the start of June, the May and June snowpacks were considered to be equal. The precipitation that falls during May would essentially offset any snowmelt that occurs. Table 5.7.2-2 presents the 100-year all season snowpack SWE averaged by sub-basin. The runoff model separates the 100-year SWE values within each sub-basin by 1000-foot elevation bands. 5.7.3. Probable Maximum Snowpack The evaluation of a 100-year precipitation on a Probable Maximum Snowpack is required in areas where snowpack may make a significant contribution to the PMF (FERC 2001). In many cases, it can be enough to simply assume an unlimited snowpack and if the resulting PMF is less than for the PMP on 100-year snowpack case, then the Probable Maximum Snowpack scenario can be dismissed, which is the usual result. A more reasonable Probable Maximum Snowpack is developed for Watana Dam in this section. The Yukon River watershed lies to the north and east of the Susitna River watershed and is in places adjacent to the Susitna River watershed. The Weather Bureau (1966) has prepared a hydrometeorological report (HMR 42) for the Yukon River and preparation of a Probable INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 15 February 2014 Draft Maximum Snowpack for the Yukon River was a major part of the report. Results of the HMR 42 are applicable to the Susitna River watershed. The HMR 42 Yukon River final result was that the Probable Maximum Snowpack was equal to 3.0 times the October through April cumulative average precipitation, based on an enveloping analysis of historic October through April precipitation data. The Susitna River watershed tributary to Watana Dam lacks this type of long-term precipitation data. In terms of May 1 recorded snow course SWE as a ratio to October through April average precipitation, the maximum recorded year values for the area in or near the area tributary to Watana Dam are significantly less than 3.0. Although it is a very approximate comparison, a snowpack of 3.0 times the average snowpack on May 1 would be more rare than a calculated 10,000-year event at many of the snow course stations, which would be appropriately rare for a probable maximum event. The adopted Probable Maximum Snowpack for the watershed tributary to Watana Dam will be 3.0 times the average October through April precipitation. The method of snowpack distribution over the watershed will be the same as for the 100-year snowpack. The average Probable Maximum Snowpack SWE for each sub-basin is presented on Table 5.7.3-1. The average Probable Maximum Snowpack SWE in the area tributary to Watana Dam is 27.9 inches, which compares to the Weather Bureau result of 15.7 inches Probable Maximum Snowpack for the upper Yukon River. 5.8. Runoff Model Calibration Floods Preference for selection of historic floods for calibration and verification was based on:  The largest floods of record;  The floods with data at the most USGS gages  The floods with the most complete flow data near the peak flow  Distribution of floods in the May through October potential flood season  Storms used for calibration in the 1980s PMF studies  Storms used for PMP development The flood periods selected for calibration and verification of hydrograph parameters are: 1. June 1964 2. August 1967 3. June 1971 4. August 1971 5. June 1972 6. September 2012 Consideration was given to the June 1964 flood because it has the largest peak flow and the largest daily average flow of record at Gold Creek and is the second largest flood of record at Cantwell. It was also the 10th largest flood of record on the Maclaren River, and the largest flow of the year at Denali. Because of the magnitude of the flood at Gold Creek and Cantwell and the INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 16 February 2014 Draft availability of flow data at all four USGS gages, June 1964 was selected for use in the calibration and verification of hydrograph parameters. The August 1967 period was used as a calibration flood in the 1982 Susitna PMF study and was also selected for PMP analysis. It had the 5th highest peak flows at Gold Creek and Cantwell, the 2nd highest peak flow of record at Denali, and the 3rd highest peak flow on the Maclaren River. Although a peak flow value is available at Denali, no daily flow data is available. Data availability and the magnitude of the flood are sufficient for selection of the August 1967 period as one of the floods for calibration and verification of hydrograph parameters. June 1971 was used as a calibration flood in the 1982 Susitna PMF study. Data is available at all four USGS gages. It is the 7th largest partial duration flood of record at Gold Creek and has the 3rd highest partial duration flow of record at Cantwell. The shape of the hydrograph appears to be well-suited for calibration. Because of data availability and flood magnitude, June 1971 is selected. As an example of recorded flood data, the available flow data for June 1971 are shown on Figure 5.8-1. August 1971 was used as a calibration flood in the 1982 Susitna PMF study. Data is available at all four USGS gages and it was also selected as a PMP evaluation storm. It is the maximum flood of record at Cantwell, Denali, and the Maclaren River, and the 2nd largest flood of record at Gold Creek. Because of data availability at all four USGS gages and because of the flood magnitude, August 1971 is selected for calibration and verification of flood hydrograph parameters. June 1972 was one of the calibration floods in the 1982 Susitna PMF study. Data is available at all four USGS gages. It is the 3rd largest peak flow of record at Gold Creek, the 4th largest at Cantwell, and the 6th largest on the Maclaren River. Because of data availability and the magnitude of the flood, the June 1972 period is selected for calibration and verification of hydrograph parameters. The September 2012 flood was selected for further PMP analysis. Data is currently available at the USGS gages at Gold Creek, Denali, and the new gage below Tsusena Creek. The September 2012 flood was the largest flood at Gold Creek in the past 40 years, the 6th largest on record, and by far the largest flow ever recorded in September. Because of the exceptional nature of this September flood, and because of the availability of more meteorological data than for other floods, the September 2012 flood is selected for calibration and verification of unit hydrograph parameters. 5.9. Probable Maximum Precipitation Previous PMP and storm analysis work in the region were reviewed to identify storm events, available rainfall data and techniques applicable to the basin. Previous site-specific PMP studies were reviewed for procedures that are applicable. Discussions were drafted for inclusion in the final report to summarize the applicability of the previously used procedures. PMP-type storm events which have occurred in a region that were considered transpositionable to the basin were identified in the storm search. Storms identified included storms used in INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 17 February 2014 Draft previous PMP and hydrologic studies in the region. The resulting list of storms was used to derive the PMP values for the basin for the all season PMP and the seasonally adjusted PMP. Table 5.9-1 presents the short list of storms used to determine the PMP values in this analysis. A comprehensive list of significant storm events and the characteristics of the PMP type storm(s) relevant to the basin was constructed. All storms on the short list were fully analyzed using the SPAS. The SPAS program allowed for the development of rainfall grids on a 1/3rd of a square mile resolution at hourly (or 5-minute with NEXRAD) temporal increments. Figure 5.9-1 shows an example of the total storm isohyetal pattern for a SPAS storm analysis. The program follows the same basic procedures used in the HMRs to develop Depth-Area-Duration (DAD) and mass curve information. These analysis results were used to develop the PMP values and provided the required information to calculate the orographic transposition factor. Nine new SPAS storm analyses were completed. Figure 5.9-2 shows the locations of rainfall centers associated with the nine storms. Total adjustment factors were calculated for each of the storms on the short storm list. This included an update of the 2 sigma sea surface temperature climatology that was completed for other PMP studies along the West Coast. This update extended that climatology to include all of the Gulf of Alaska and northern Pacific Ocean to ensure all areas that could supply atmospheric moisture for extreme rainfall events were included. The total adjustment factor is a combination of the in-place maximization factor, the moisture transposition factor, and the orographic transposition factor. The in-place maximization factors for all short list storms were calculated. This procedure follows the standard procedures as outlined in the HMRs and the World Meteorological Organization (WMO) PMP manual. This procedure has been used during PMP studies completed over the previous 15 years. Trajectory model analyses were completed for each of the short list storms to provide guidance in determining the storm moisture inflow vector. Figure 5.9-3 shows an example of a trajectory model analysis. Each storm was transpositioned to the basin using standard procedures outlined in the HMRs and WMO manuals and previous PMP studies conducted by the consultant. Upwind and within basin mountainous regions are being analyzed to determine the effect on moisture availability and rainfall production within the basin. This process can either enhance storm dynamics or deplete available atmospheric moisture, thereby affecting the resulting rainfall. The orographic transposition factor is being calculated to quantify the difference in orographic effects from the in-place storm location and the Susitna-Watana drainage basin. A meteorological time series was developed for use in rain on snow PMF modeling. Information from six storms was used in model calibration efforts. Daily and hourly time series were developed for meteorological parameters (i.e. temperature, dew point, wind) required for snow melt modeling using data from surrounding weather stations (e.g. NWS COOP, RAWS, SNOTEL, and various other networks). A data set was provided that represented the environment which occurred prior to, during, and immediately following the storm events used to derive the PMP values when rain on snow is a consideration. Storm dates associated with rain-on-snow rainfall events in the region were used to develop the meteorological input parameters for each hour of a period required for hydrologic modeling. The average thermal structure during extreme rainfall events was provided as input for PMF modeling to support snowmelt calculations. The meteorological variables associated with the pre-storm and storm environment starting prior to the beginning of rainfall and continuing through the rainfall period INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 18 February 2014 Draft were analyzed for the storms on the short list. These parameters were supplied to the hydrologist for inclusion in the hydrologic model analyses and specifically for the energy budget equation used to calculate the rate and amount of snowmelt which would reasonably be expected to occur prior to and coincident with the PMP event. This allowed for an accurate representation of the conditions that could be expected during a rain-on-snow PMP scenario based on actual storm data and physically possible meteorological parameters. The site-specific PMP values is being derived for the basin required for PMF calculations. These results are being provided on a gridded basis (.025DD x .025DD resolution) similar to the grid spacing used in several other PMP studies completed or in progress. Also, DAD tables were provided in the same format as given in the HMRs for comparison and sensitivity purposes. Results were also provided on a sub-basin level. 5.10. Review of Previous PMF Studies A comparison of the current study snowpack results to those obtained during the 1980s Susitna PMF studies is instructive. The 1982 Acres June PMF had a 51 inch SWE in the area tributary to Watana Dam site, and a 49 inch SWE even after eliminating the glacier areas that were assigned an essentially unlimited 99 inch SWE. The Harza-Ebasco May (maximum) snowpack shown on Table 5.10-1 has an average SWE of 16.8 inches, which is comparable to the 15.7 inch May-June 100-year snowpack developed for the current study. The 1982 Acres PMF snowpack SWE appears to be the result of excessive conservatism as it is about 75 percent greater than the Probable Maximum Snowpack as determined in the current study and 5.5 times the average October through April precipitation. A site-specific PMP is being prepared for the current PMF study, but a comparison of the PMPs from the 1980s studies with the snowpack SWE provides useful information on PMF runoff volume potential. The 1982 Acres June PMP was an average of 8.7 inches over the watershed tributary to Watana Dam, compared to the snowpack average SWE of 49 inches. The 1984 Harza-Ebasco July-August PMP was an average of 6.85 inches over the basin, the June PMP was 6.37 inches and the May PMP was an average of 5.00 inches, which combined with the average May SWE of 16.8 inches to form the critical PMF runoff in that study. These values indicate that snowmelt is likely to be the dominant factor in PMF runoff volume at Watana Dam. 6. DISCUSSION Data gathering to develop the PMP has been completed and the available data was adequate. Development of the all-season and seasonal PMP values are ongoing. The seasonal PMP values and coincident meteorological conditions are expected to be available for review by the BOC in March 2014. Data gathering to develop the rainfall-runoff model to develop and route the PMF has been completed and the available data was adequate. Development and distribution of the antecedent snowpack has been completed. Calibration and verification of hydrograph parameters is ongoing. Development of the monthly PMF inflow hydrographs and determination of the critical PMF inflow condition will logically follow development of the seasonal PMP values. INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 19 February 2014 Draft 7. PLANS FOR 2014 [As explained in the cover letter to this draft ISR, AEA’s plan for completing this study will be included in the final ISR filed with FERC on June 3, 2014.] 8. LITERATURE CITED Acres. 1982. Feasibility Report, Susitna Hydroelectric Project, Volume 4, Appendix A, Hydrological Studies, Final Draft. AEA (Alaska Energy Authority). 2012. Revised Study Plan: Susitna-Watana Hydroelectric Project FERC Project No. 14241. December 2012. Prepared for the Federal Energy Regulatory Commission by the Alaska Energy Authority, Anchorage, Alaska. http://www.susitna-watanahydro.org/study-plan. FERC (Federal Energy Regulatory Commission). September 2001. Engineering Guidelines for the Evaluation of Hydroelectric Projects, Chapter VIII, Determination of the Probable Maximum Flood. FERC (Federal Energy Regulatory Commission). May 31, 2012. “Request for Studies and Comments on Preliminary Study Plan”, letter from Jennifer Hill, Chief, Northwest Branch, Division of Hydropower Licensing to Wayne Dyok, Project Manager, Alaska Energy Authority. Harza-Ebasco Susitna Joint Venture. January 1984. Probable Maximum Flood for Watana and Devil Canyon Sites, Susitna Hydroelectric Project, Draft Report, Document No. 457. Miller, John F., 1963. Probable Maximum Precipitation and Rainfall-Frequency Data for Alaska, Technical Paper No. 47, Weather Bureau, U.S. Department of Commerce. U.S. Army Corps of Engineers (USACE), 1991, Inflow Design Floods for Dams and Reservoirs, ER 1110-8-2(FR), March 1, 1991. U.S. Army Corps of Engineers (USACE), 1984. Shore Protection Manual, Coastal Engineering Research Center, Waterways Experiment Station, Second Printing. U.S. Army Corps of Engineers (USACE), July 31, 2003. Coastal Engineering Manual, EM- 1110-2-1100, Part II Coastal Hydrodynamics. Weather Bureau. May 1966. Hydrometeorological Report No. 42, Meteorological Conditions for the Probable Maximum Flood on the Yukon River Above Rampart, Alaska, U.S. Department of Commerce, Environmental Science Services Administration, Office of Hydrology, Hydrometeorological Branch. INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 20 February 2014 Draft 9. TABLES Table 5.3- 1. USGS Streamflow Gages in the Susitna Watershed USGS Gage Number Gage Name Drainage Area (sq.mi) Latitude Longitude Gage Datum (feet) Available Period of Record 15290000 Little Susitna River near Palmer 62 61°42'37"149°13'47"917 1948 - 2013 15291000 Susitna River near Denali 950 63°06'14"147°30'57"2,440 1957 - 1976; 1978 - 1986; 2012 15291200 Maclaren River near Paxson 280 63°07'10"146°31'45"2,866 1958 - 1986 15291500 Susitna River near Cantwell 4,140 62°41'55"147o32'42"1,900 1961 - 1972; 1980 - 1986 15291700 Susitna River above Tsusena Creek 5,160 62°49'24"147o36'17"1,500 2013 15292000 Susitna River at Gold Creek 6,160 62o46'04"149o41'28"677 1949 - 1996; 2001 - 2013 15292400 Chulitna River near Talkeetna 2,570 62°33'31"150°14'02"520 1958 - 1972; 1980 - 1986 15292700 Talkeetna River near Talkeetna 1,996 62°20'49"150°01'01"400 1964 - 1972; 1980 - 2013 15292780 Susitna River at Sunshine 11,100 62o10'42"150o10'30"270 1981 - 1986; 2012 - 2013 15292800 Montana Creek near Montana 164 62°06'19"150°03'27"250 2005 - 2006; 2008 - 2012 15294005 Willow Creek Near Willow 166 61°46'51"149°53'04"350 1978 - 1993; 2001 - 2013 15294010 Deception Creek near Willow 48 61°44'52"149°56'14"250 1978 - 1985 15294100 Deshka River near Willow 591 61°46'05"150°20'13"80 1978 - 1986; 1988 - 2001 15294300 Skwentna River near Skwentna 2,250 61°52'23"151°22'01"200 1959 - 1982 15294345 Yentna River near Susitna Station 6,180 61°41'55"150°39'02 80 1980 - 1986 15294350 Susitna River at Susitna Station 19,400 61°32'41"150°30'45 40 1974 - 1993 INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 21 February 2014 Draft Table 5.3- 2. Snow Course and SNOTEL Stations In or Near the Susitna Watershed Station In Susitna R.Latitude Longitude Elevation Years of Available Snowpack Number Watershed (1)(deg:min)(deg:min)(feet)Data In the Period of Record Anchorage Hillside 1070 SNOTEL No N 61:07 W 149:40 2,080 8 years: 2006 - 2013 Bentalit Lodge 1086 SNOTEL Yes N 61:56 W 150:59 150 8 years: 2006 - 2013 Fairbanks F.O.1174 SNOTEL No N 64:51 W 147:48 450 31 years: 1983 - 2013 Granite Creek 963 SNOTEL No N 63:57 W 145:24 1,240 26 years: 1988 - 2013 Independence Mine 1091 SNOTEL Border N 61:48 W 149:17 3,550 16 years: 1998 - 2013 Indian Pass 946 SNOTEL No N 61:04 W 149:29 2,350 34 years: 1980 - 2013 Monohan Flat (4)1094 SNOTEL Border N 63:18 W 147:39 2,710 6 years: 2008 - 2013 Mt. Alyeska 1103 SNOTEL No N 60:58 W 149:05 1,540 40 years: 1973 - 2013 Munson Ridge 950 SNOTEL No N 64:51 W 146:13 3,100 33 years: 1981 - 2013 Susitna Valley High 967 SNOTEL Yes N 62:08 W 150:02 375 27 years: 1988 - 2013 Tokositna Valley 1089 SNOTEL Yes N 62:38 W 150:47 850 8 years: 2006 - 2013 Blueberry Hill 49N07 Snow Course Yes N 62:48 W 149:59 1,200 26 years: 1988 - 2013 Clearwater Lake 46N01 Snow Course Yes N 62:56 W 146:57 2,650 47 years: 1964 - 2013 E. Fork Chulitna River 47N02 Snow Course Yes N 63:08 W 149:27 1,800 26 years: 1988 - 2013 Fog Lakes 48N02 Snow Course Yes N 62:47 W 148:28 2,120 50 years: 1964 - 2013 Horsepasture Pass 47N02 Snow Course Border N 62:08 W 147:38 4,300 46 years: 1968 - 2013 Independence Mine 49M26 Snow Course Border N 61:48 W 149:17 3,550 25 years: 1989 - 2013 Lake Louise 46N02 Snow Course Yes N 62:16 W 146:31 2,400 50 years: 1964 - 2013 Monohan Flat 47O01 Snow Course Border N 63:18 W 147:39 2,710 49 years: 1964 - 2013 Monsoon Lake 46N03 Snow Course Border N 62:50 W 146:37 3,100 29 years: 1985 - 2013 Square Lake 47N01 Snow Course Yes N 62:24 W 147:28 2,950 50 years: 1964 - 2013 Susitna Valley High 50N07 Snow Course Yes N 62:08 W 150:02 375 19 years: 1988 - 2012 Talkeetna 50N02 Snow Course Yes N 62:19 W 150:05 350 47 years: 1967 - 2013 Tyone River 47N03 Snow Course Yes N 62:40 W 147:08 2,500 21 years: 1981 - 2011 Notes: (1) Items in bold indicate the location is tributary to Watana Dam. Border indicates the station is on or near the watershed border. Station Name Station Type INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 22 February 2014 Draft Table 5.4- 1. Area in Elevation Bands to Watana Dam Basin Area in Elevation Bands (sq.mi.) for Model with Reservoir % of No.1-2000 2-3000 3-4000 4-5000 5-6000 6-7000 7-8000 8-9000 9-10000 10-11000 11-14000 Total Total 1 0.0 0.0 8.7 19.7 8.9 11.3 3.9 0.2 0.0 0.0 0.0 52.7 1.02% 2 0.0 16.4 105.6 65.3 32.3 7.0 0.4 0.0 0.0 0.0 0.0 226.9 4.39% 3 0.0 145.7 139.5 9.8 0.2 0.0 0.0 0.0 0.0 0.0 0.0 295.2 5.71% 4 0.0 3.5 18.2 28.5 34.4 32.5 17.1 9.2 3.8 1.4 0.8 149.4 2.89% 5 0.0 90.7 93.0 99.8 48.5 18.5 3.6 0.0 0.0 0.0 0.0 354.2 6.85% 6 0.0 3.6 23.1 39.8 37.0 29.8 14.0 3.4 1.5 0.9 0.4 153.4 2.97% 7 0.0 55.2 9.4 2.1 0.8 0.0 0.0 0.0 0.0 0.0 0.0 67.5 1.31% 8 0.0 54.3 60.4 59.5 15.8 0.1 0.0 0.0 0.0 0.0 0.0 190.1 3.68% 9 0.0 38.5 91.3 52.5 5.3 0.0 0.0 0.0 0.0 0.0 0.0 187.6 3.63% 10 0.0 180.0 113.2 28.1 5.5 0.0 0.0 0.0 0.0 0.0 0.0 326.9 6.32% 11 0.0 72.4 130.2 57.0 13.7 0.4 0.0 0.0 0.0 0.0 0.0 273.6 5.29% 12 0.0 48.7 23.7 2.4 0.0 0.0 0.0 0.0 0.0 0.0 0.0 74.7 1.45% 13 0.0 202.6 20.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 222.6 4.30% 14 0.0 131.5 3.7 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 135.2 2.61% 15 0.0 68.0 87.9 29.3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 185.2 3.58% 16 0.0 41.6 100.5 22.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 164.4 3.18% 17 0.0 223.2 27.3 2.6 0.2 0.0 0.0 0.0 0.0 0.0 0.0 253.3 4.90% 18 0.0 0.1 28.7 48.2 21.2 1.8 0.0 0.0 0.0 0.0 0.0 100.0 1.93% 19 0.0 0.6 45.9 77.9 62.9 14.4 0.5 0.0 0.0 0.0 0.0 202.2 3.91% 20 0.0 16.5 19.8 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 36.3 0.70% 21 0.0 7.2 48.4 52.3 42.3 11.6 1.0 0.0 0.0 0.0 0.0 162.7 3.15% 22 0.0 76.3 14.0 1.7 0.0 0.0 0.0 0.0 0.0 0.0 0.0 92.0 1.78% 23 0.0 41.0 88.7 35.1 4.0 0.0 0.0 0.0 0.0 0.0 0.0 168.9 3.27% 24 0.0 51.6 89.5 20.2 1.5 0.0 0.0 0.0 0.0 0.0 0.0 162.8 3.15% 25 0.0 5.3 42.0 72.4 54.0 10.2 0.1 0.0 0.0 0.0 0.0 184.0 3.56% 26 0.0 37.1 115.5 51.0 17.2 2.1 0.0 0.0 0.0 0.0 0.0 222.9 4.31% 27 0.0 141.0 92.5 33.3 2.8 0.1 0.0 0.0 0.0 0.0 0.0 269.6 5.21% 28 0.0 62.2 88.5 61.7 8.8 0.0 0.0 0.0 0.0 0.0 0.0 221.1 4.28% 29 0.0 36.8 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 36.8 0.71% Total 0.0 1851.4 1729.1 972.2 417.6 139.8 40.6 12.8 5.3 2.3 1.3 5172.3 100.00% 0.00%35.79%33.43%18.80%8.07%2.70%0.78%0.25%0.10%0.04%0.02%100.00% INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 23 February 2014 Draft Table 5.4- 2. Susitna Watershed Land Cover Table 5.5- 1. Recorded Peak Flows – Susitna River at Gold Creek – 59 Years of Record To Gold Creek without Reservoir Area % of Code Description (sq. mi.)Total 52 Shrub/Scrub 2784.0 45.3% 42 Evergreen Forest 996.4 16.2% 31 Barren Land (Rocks/Sand/Clay)925.9 15.1% 51 Dwarf Scrub 652.9 10.6% 90 Woody Wetlands 238.9 3.9% 12 Perennial Ice/Snow 234.3 3.8% 11 Open Water 180.3 2.9% 43 Mixed Forest 56.4 0.9% 41 Deciduous Forest 54.2 0.9% 72 Sedge/Herbaceous 14.6 0.2% 95 Emergent Herbaceous Wetlands 2.9 0.0% 22 Developed, Low Intensity 1.7 0.0% 71 Grassland/Herbaceous 1.6 0.0% 21 Developed, Open Space 0.1 0.0% 23 Developed, Medium Intensity 0.01 0.0% Total 6144.1 100.0% Rank Date Peak Flow (cfs)cfs/sq.mi. 1 June 7, 1964 90,700 14.7 2 August 10, 1971 87,400 14.2 3 June 17, 1972 82,600 13.4 4 June 15, 1962 80,600 13.1 5 August 15, 1967 80,200 13.0 6 September 21, 2012 72,900 11.8 7 July 12, 1981 64,900 10.5 8 June 6, 1966 63,600 10.3 9 August 25, 1959 62,300 10.1 10 August 20, 2006 59,800 9.7 INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 24 February 2014 Draft Table 5.5- 2. Recorded Peak Flows – Susitna River at Cantwell – 18 Years of Record Table 5.5- 3. Recorded Peak Flows – Susitna River near Denali – 28 Years of Record Table 5.5- 4. Recorded Peak Flows – Maclaren River near Paxson – 28 Years of Record Rank Date Peak Flow (cfs)cfs/sq.mi. 1 August 10, 1971 55,000 13.3 2 June 8, 1964 51,200 12.4 3 June 15, 1962 46,800 11.3 4 June 17, 1972 44,700 10.8 5 August 14, 1967 38,800 9.4 6 June 16, 1984 33,400 8.1 7 July 18, 1963 32,000 7.7 8 August 14, 1981 30,900 7.5 9 June 23, 1961 30,400 7.3 10 July 29, 1980 28,500 6.9 Rank Date Peak Flow (cfs)cfs/sq.mi. 1 August 10, 1971 38,200 40.2 2 August 14, 1967 28,200 29.7 3 July 28, 2003 27,800 29.3 4 September 21, 2012 25100 26.4 5 July 28, 1980 24,300 25.6 6 August 9, 1981 23,200 24.4 7 August 4, 1976 22,100 23.3 8 July 12, 1975 21,700 22.8 9 June 7, 1957 18,700 19.7 10 July 7, 1983 18,700 19.7 Rank Date Peak Flow (cfs)cfs/sq.mi. 1 August 11, 1971 9,260 33.1 2 September 13, 1960 8,920 31.9 3 August 14, 1967 7,460 26.6 4 July 18, 1963 7,300 26.1 5 July 2, 1985 7,190 25.7 6 June 16, 1972 7,070 25.3 7 August 10, 1981 6,650 23.8 8 August 5, 1961 6,540 23.4 9 June 14, 1962 6,540 23.4 10 June 7, 1964 6,400 22.9 INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 25 February 2014 Draft Table 5.6- 1. Maximum Daily Flows for Each Month for the USGS Gage at Gold Creek Table 5.6- 2. Monthly Distribution of Annual Peak Flows Gold Creek USGS Gage Maximum Daily Flow (cfs) January 2,900 February 3,700 March 2,400 April 24,000 May 55,500 June 85,900 July 60,800 August 77,700 September 70,800 October 36,200 November 8,940 December 4,400 Gold Creek Gage Cantwell Gage Denali Gage Maclaren Gage Total of All Gages Month Annual % of Annual % of Annual % of Annual % of Annual % of Peaks Total Peaks Total Peaks Total Peaks Total Peaks Total January 0 0%0 0%0 0%0 0%0 0% February 0 0%0 0%0 0%0 0%0 0% March 0 0%0 0%0 0%0 0%0 0% April 0 0%0 0%0 0%0 0%0 0% May 8 14%1 6%0 0%1 4%10 7% June 28 47%8 44%3 10%12 43%51 38% July 9 15%5 28%12 41%6 21%32 24% August 10 17%4 22%12 41%7 25%33 25% September 4 7%0 0%2 7%2 7%8 6% October 0 0%0 0%0 0%0 0%0 0% November 0 0%0 0%0 0%0 0%0 0% December 0 0%0 0%0 0%0 0%0 0% Total 59 100%18 100%29 100%28 100%134 100% INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 26 February 2014 Draft Table 5.7.1- 1. Monthly Precipitation by Month and Sub-Basin Table 5.7.2- 1. 100-Year Snowpack at Snow Course Stations Sub-Basin Basin Area Average Precipitation (inches)Oct-Apr Number (sq.mi.)Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Annual Oct-Apr % of Year 1 52.6 1.73 2.61 2.07 1.54 1.67 3.46 4.36 5.85 5.61 4.32 2.01 2.64 37.88 16.92 44.7% 2 226.4 1.26 1.79 1.40 1.11 1.34 2.86 3.75 4.60 4.15 3.30 1.44 1.95 28.94 12.24 42.3% 3 295.4 0.81 0.71 0.61 0.59 1.10 2.34 2.93 2.85 2.19 1.92 0.84 1.18 18.08 6.66 36.8% 4 149.3 2.38 2.73 2.49 1.60 1.76 3.72 4.84 6.29 5.83 4.44 2.43 3.14 41.66 19.22 46.1% 5 354.0 1.61 1.97 1.55 1.14 1.37 3.04 4.10 4.73 4.21 3.29 1.62 2.26 30.91 13.45 43.5% 6 153.4 2.67 2.60 2.21 1.65 1.62 3.83 5.39 6.31 5.79 4.68 2.33 3.74 42.84 19.90 46.4% 7 67.5 1.43 1.24 0.92 0.81 1.11 2.93 3.98 3.59 2.78 2.35 1.14 1.65 23.93 9.54 39.9% 8 189.9 1.35 1.67 1.29 1.01 1.28 2.87 3.85 4.35 3.85 2.96 1.41 1.88 27.76 11.57 41.7% 9 187.7 1.42 1.32 1.00 0.97 1.30 3.11 4.20 4.24 3.57 2.75 1.34 1.72 26.93 10.50 39.0% 10 326.8 0.94 0.97 0.72 0.76 1.13 2.35 3.24 3.70 2.94 2.36 0.90 1.31 21.31 7.96 37.3% 11 273.5 1.02 1.06 0.87 0.84 1.17 2.57 3.33 3.71 3.18 2.62 1.07 1.47 22.91 8.95 39.1% 12 74.7 0.69 0.57 0.54 0.51 1.08 2.28 2.86 2.69 2.01 1.61 0.79 1.12 16.76 5.84 34.9% 13 222.5 0.54 0.45 0.44 0.32 1.04 2.31 2.68 1.82 1.55 1.22 0.77 1.05 14.20 4.79 33.7% 14 135.1 0.47 0.41 0.38 0.26 1.06 2.34 2.70 1.75 1.64 1.25 0.66 0.90 13.81 4.32 31.3% 15 185.1 0.61 0.56 0.60 0.44 1.14 2.48 2.94 2.18 1.68 1.32 0.95 1.28 16.17 5.75 35.6% 16 164.3 0.60 0.50 0.58 0.51 1.18 2.53 3.02 2.36 1.85 1.44 0.95 1.30 16.83 5.88 34.9% 17 253.2 0.57 0.47 0.51 0.35 1.05 2.24 2.71 2.17 1.71 1.32 0.79 1.08 14.97 5.09 34.0% 18 100.0 0.69 1.00 0.89 0.75 1.45 3.01 3.57 2.92 2.35 1.75 1.03 1.40 20.81 7.52 36.1% 19 202.2 0.77 1.01 0.91 1.15 1.99 3.30 3.84 3.35 3.19 2.33 1.12 1.55 24.52 8.85 36.1% 20 36.3 0.52 0.46 0.47 0.63 1.26 2.49 3.03 2.72 2.21 1.58 0.76 1.04 17.15 5.45 31.8% 21 162.7 0.79 0.81 0.78 1.29 1.87 2.94 3.84 3.71 4.08 2.70 1.21 1.57 25.59 9.15 35.8% 22 92.0 0.56 0.46 0.49 0.54 1.05 2.24 2.83 2.73 2.05 1.59 0.77 1.08 16.40 5.50 33.6% 23 174.2 0.67 0.58 0.57 0.86 1.39 2.57 3.34 3.57 3.02 2.21 0.90 1.22 20.91 7.02 33.6% 24 157.4 0.86 0.75 0.63 0.85 1.23 2.48 3.45 3.86 3.04 2.46 0.99 1.28 21.89 7.84 35.8% 25 184.0 1.16 1.02 0.80 1.66 1.76 3.50 4.72 5.59 5.76 3.96 1.72 1.92 33.57 12.24 36.5% 26 222.9 1.02 0.92 0.75 1.32 1.40 2.99 4.35 4.72 4.06 3.07 1.46 1.60 27.67 10.14 36.6% 27 269.6 1.08 1.04 0.84 0.94 1.18 2.62 3.66 4.00 3.19 2.28 1.39 1.42 23.63 8.99 38.0% 28 218.5 1.20 1.23 1.03 0.99 1.22 2.89 4.05 4.44 3.71 2.15 1.78 1.66 26.35 10.04 38.1% 29 36.8 0.76 0.73 0.60 0.75 0.99 2.19 2.99 3.25 2.58 1.78 1.03 1.06 18.70 6.71 35.9% 30 146.4 1.32 1.42 1.23 1.20 1.36 2.91 4.22 4.79 4.12 2.19 2.16 1.88 28.78 11.40 39.6% 31 181.9 1.03 1.08 0.87 1.29 1.30 3.05 4.05 4.77 4.14 2.27 1.64 1.37 26.87 9.55 35.6% 32 208.1 1.02 1.48 1.39 1.53 1.52 2.86 3.85 4.69 4.10 1.75 2.59 1.72 28.49 11.47 40.3% 33 273.4 1.57 1.67 1.59 1.49 1.48 2.97 4.13 5.04 4.40 2.16 2.57 2.21 31.29 13.26 42.4% 34 164.8 2.07 1.98 1.87 1.48 1.21 3.04 4.57 6.27 5.45 3.69 2.28 2.69 36.60 16.06 43.9% To Gold Creek Gage 6,143 1.11 1.17 1.01 0.99 1.32 2.80 3.70 3.97 3.45 2.46 1.40 1.67 25.04 9.80 39.1% To Watana Dam 5,168 1.05 1.10 0.93 0.91 1.31 2.77 3.61 3.76 3.26 2.48 1.24 1.61 24.03 9.32 38.8% To Denali Gage 914 1.85 2.08 1.71 1.25 1.44 3.24 4.37 5.09 4.56 3.57 1.79 2.53 33.50 14.79 44.2% To Maclaren Gage 279 1.35 1.94 1.52 1.19 1.40 2.97 3.86 4.84 4.42 3.49 1.55 2.08 30.62 13.12 42.8% To Cantwell Gage 4,079 1.05 1.13 0.96 0.85 1.30 2.74 3.51 3.58 3.10 2.42 1.17 1.62 23.44 9.20 39.3% Is Station Area 100-Year Snow Water Equivalent Oct-Apr Avg.Ratio May 1 Tributary to Elevation Feb. 1 Mar. 1 Apr. 1 May 1 Total Precip.100-Year / Watana Dam (1)(feet)(inches)(inches)(inches)(inches)(inches)Oct-Apr (2) Blueberry Hill No 1,200 24.0 32.8 36.5 33.8 16.9 2.01 Clearwater Lake Yes 2,650 8.1 8.2 9.8 11.6 6.0 1.94 E. Fork Chulitna River No 1,800 23.6 28.8 31.5 34.3 11.8 2.90 Fog Lakes Yes 2,120 11.6 12.1 12.9 11.9 6.7 1.78 Horsepasture Pass Yes/Border 4,300 9.4 11.8 12.5 12.8 7.0 1.82 Independence Mine No 3,550 39.6 48.1 50.1 50.1 24.5 2.05 Lake Louise Yes 2,400 6.7 7.1 8.2 7.2 4.4 1.63 Monohan Flat Yes/Border 2,710 12.7 13.8 14.7 12.0 8.5 1.40 Monsoon Lake Yes/Border 3,100 8.3 9.6 10.8 -----6.0 1.79 Square Lake Yes 2,950 6.0 6.5 7.4 7.2 4.8 1.51 Susitna Valley High No 375 13.6 15.5 16.5 19.0 13.3 1.43 Talkeetna No 350 11.3 15.9 18.4 16.7 12.0 1.39 Tyone River Yes 2,500 5.7 6.2 7.3 -----4.8 1.53 Average of non-red values 1.68 Notes: (1) Border indicates that the stations are on or near the watershed boundary. (2) Where May 1 data is missing, April 1 data was used. Values in the red boxes were not used to determine the 100-year snowpack. Station Name INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 27 February 2014 Draft Table 5.7.2- 2. 100-Year All-Season Snowpack SWE Basin Annual Oct-Apr 100-Year Sub-Basin Area Precip.Precip.SWE Number (sq.mi.)(inches)(inches)(inches) 1 52.6 37.9 16.9 28.4 2 226.4 28.9 12.2 20.6 3 295.4 18.1 6.7 11.2 4 149.3 41.7 19.2 32.3 5 354.0 30.9 13.5 22.6 6 153.4 42.8 19.9 33.4 7 67.5 23.9 9.5 16.0 8 189.9 27.8 11.6 19.4 9 187.7 26.9 10.5 17.6 10 326.8 21.3 8.0 13.4 11 273.5 22.9 9.0 15.0 12 74.7 16.8 5.8 9.8 13 222.5 14.2 4.8 8.0 14 135.1 13.8 4.3 7.3 15 185.1 16.2 5.8 9.7 16 164.3 16.8 5.9 9.9 17 253.2 15.0 5.1 8.5 18 100.0 20.8 7.5 12.6 19 202.2 24.5 8.8 14.9 20 36.3 17.1 5.4 9.2 21 162.7 25.6 9.2 15.4 22 92.0 16.4 5.5 9.2 23 174.2 20.9 7.0 11.8 24 157.4 21.9 7.8 13.2 25 184.0 33.6 12.2 20.6 26 222.9 27.7 10.1 17.0 27 269.6 23.6 9.0 15.1 28 218.5 26.3 10.0 16.9 29 36.8 18.7 6.7 11.3 30 146.4 28.8 11.4 19.1 31 181.9 26.9 9.6 16.1 32 208.1 28.5 11.5 19.3 33 273.4 31.3 13.3 22.3 34 164.8 36.6 16.1 27.0 To Gold Creek Gage 6,143 25.0 9.8 16.5 To Watana Dam 5,168 24.0 9.3 15.7 To Denali Gage 914 33.5 14.8 24.9 To Maclaren Gage 279 30.6 13.1 22.0 To Cantwell Gage 4,079 23.4 9.2 15.5 INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 28 February 2014 Draft Table 5.7.3- 1. Probable Maximum Snowpack SWE Basin Annual Oct-Apr PMS Sub-Basin Area Precip.Precip.SWE Number (sq.mi.)(inches)(inches)(inches) 1 52.6 37.9 16.9 50.8 2 226.4 28.9 12.2 36.7 3 295.4 18.1 6.7 20.0 4 149.3 41.7 19.2 57.7 5 354.0 30.9 13.5 40.4 6 153.4 42.8 19.9 59.7 7 67.5 23.9 9.5 28.6 8 189.9 27.8 11.6 34.7 9 187.7 26.9 10.5 31.5 10 326.8 21.3 8.0 23.9 11 273.5 22.9 9.0 26.9 12 74.7 16.8 5.8 17.5 13 222.5 14.2 4.8 14.4 14 135.1 13.8 4.3 13.0 15 185.1 16.2 5.8 17.3 16 164.3 16.8 5.9 17.6 17 253.2 15.0 5.1 15.3 18 100.0 20.8 7.5 22.6 19 202.2 24.5 8.8 26.5 20 36.3 17.1 5.4 16.3 21 162.7 25.6 9.2 27.5 22 92.0 16.4 5.5 16.5 23 174.2 20.9 7.0 21.1 24 157.4 21.9 7.8 23.5 25 184.0 33.6 12.2 36.7 26 222.9 27.7 10.1 30.4 27 269.6 23.6 9.0 27.0 28 218.5 26.3 10.0 30.1 29 36.8 18.7 6.7 20.1 30 146.4 28.8 11.4 34.2 31 181.9 26.9 9.6 28.7 32 208.1 28.5 11.5 34.4 33 273.4 31.3 13.3 39.8 34 164.8 36.6 16.1 48.2 To Gold Creek Gage 6,143 25.0 9.8 29.4 To Watana Dam 5,168 24.0 9.3 27.9 To Denali Gage 914 33.5 14.8 44.4 To Maclaren Gage 279 30.6 13.1 39.4 To Cantwell Gage 4,079 23.4 9.2 27.6 INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 29 February 2014 Draft Table 5.10- 1. Harza-Ebasco PMF Snowpack Estimate Harza-Ebasco Drainage Wtd. Avg. Sub-basin Area Sub-Basin Vicinity SWE Number (sq.mi.)(inches) 2 460 Watnana Creek 15.8 3 580 Kosina Creek 17.1 4 725 Black River 18.1 5 1,060 Tyone River 14.6 6 790 Coal Creek 15.7 7 188 W. Fork Susitna to Denali 17.0 8 762 Susitna R. above Denali 19.7 9 335 Maclaren R. below USGS gage 14.9 10 280 Maclaren R. above USGS gage 19.6 Total 5,180 Weighted Average 16.8 Location Name State Lat Lon Year Mon Day Total Rainfall Precipitation Source OLD TYONEK AK 61.260 -151.860 2012 9 15 15.91 SPAS 1256 Zone 1 DENALI NP AK 62.829 -151.138 1986 10 8 11.01 SPAS 1267 Zone 1 SEWARD AK 60.113 -149.513 1986 10 8 20.80 SPAS 1267 Zone 2 MT GEIST AK 63.638 -146.971 1980 7 24 5.26 SPAS 1268 Zone 2 DENALI NP AK 62.954 -150.079 1980 7 24 7.33 SPAS 1268 Zone 1 BLACK RAPIDS AK 63.471 -145.479 1971 8 5 12.17 SPAS 1269 Zone 2 SUTTON AK 61.904 -148.863 1971 8 5 11.39 SPAS 1269 Zone 1 DENALI NP AK 62.846 -150.513 1967 8 2 12.45 SPAS 1270 Zone 2 FAIRBANKS AK 65.521 -147.329 1967 8 2 12.45 SPAS 1270 Zone 1 LITTLE SUSITNA AK 61.854 -149.229 1959 8 18 13.05 SPAS 1271 Zone 1 DONNELLY AK 63.496 -145.629 1958 7 25 7.06 SPAS 1273 Zone 1 DENALI NP AK 63.038 -150.471 1955 8 22 13.75 SPAS 1272 Zone 1 DENALI NP AK 63.029 -150.371 2006 8 17 SPAS 1303 Zone 1 Table 5.9- 1. Short List of Storms INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 30 February 2014 Draft 10. FIGURES Figure 5.2-1. Susitna River near Deadman Creek on May 29, 2013 Figure 5.2-2. Susitna River near the Denali Highway Crossing on May 29, 2013 INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 31 February 2014 Draft Figure 5.3- 1. Susitna Watershed Boundary and USGS Gage Locations INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 32 February 2014 Draft Figure 5.3- 2. Location of Snow Course and SNOTEL Stations INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 33 February 2014 Draft Figure 5.4- 1. Susitna Watershed Sub-Basins INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 34 February 2014 Draft Figure 5.4- 2. Susitna Watershed Elevation Bands INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 35 February 2014 Draft Figure 5.4- 3. Susitna Watershed Land Cover INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 36 February 2014 Draft Figure 5.6- 1. Historic Flow Frequency at the USGS Gold Creek Gage Figure 5.6- 2. Watana Reservoir Simulated Elevations 0 10,000 20,000 30,000 40,000 50,000 60,000 70,000 80,000 90,000 100,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov DecDaily Flow (cfs)Maximum 1% Exceedance 5% Exceedance 50% Exceedance 90% Exeedance Based on Historic Recorded Daily Flows in the Susitna River at at Gold Creek -USGS Gage 15292000 1800 1850 1900 1950 2000 2050 2100 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov DecReservoir Elevation (feet)Maximum Median Minimum Pool Based on 56 years of simulated daily reservoir elevations. INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 37 February 2014 Draft Figure 5.7.1- 1. Average October through April Precipitation INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 38 February 2014 Draft Figure 5.8- 1. Recorded Flows at USGS Streamflow Gaging stations for June 1971 0 10,000 20,000 30,000 40,000 50,000 60,000 70,000 6/3/19716/4/19716/5/19716/6/19716/7/19716/8/19716/9/19716/10/19716/11/19716/12/19716/13/19716/14/19716/15/19716/16/19716/17/19716/18/19716/19/1971Flow (cfs)Susitna River at Gold Creek Susitna River at Cantwell Susitna River at Denali Maclaren River at Paxson INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 39 February 2014 Draft Figure 5.9- 1. SPAS Storm Analysis Results for the August 1967 Storm INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 40 February 2014 Draft Figure 5.9- 2. Rainfall Center Locations for the Short List Storms INITIAL STUDY REPORT PROBABLE MAXIMUM FLOOD (PMF) STUDY (16.5) Susitna-Watana Hydroelectric Project Alaska Energy Authority FERC Project No. 14241 Page 41 February 2014 Draft Figure 5.9- 3. Example of a Trajectory Model Analysis