HomeMy WebLinkAboutRiparian vegiation study downstream section 11.6 part A 2014Alaska Resources Library & Information Services
Susitna-Watana Hydroelectric Project Document
ARLIS Uniform Cover Page
Title:
Riparian vegetation study downstream of the proposed Susitna-Watana
Dam, Study plan Section 11.6 : Initial study report -- Part A: Sections 1-6,
8-10
SuWa 223
Author(s) – Personal:
Author(s) – Corporate:
ABR, Inc.-Environmental Research & Services
AEA-identified category, if specified:
Initial study report
AEA-identified series, if specified:
Series (ARLIS-assigned report number):
Susitna-Watana Hydroelectric Project document number 223
Existing numbers on document:
Published by:
[Anchorage : Alaska Energy Authority, 2014]
Date published:
June 2014
Published for:
Alaska Energy Authority
Date or date range of report:
Volume and/or Part numbers:
Final or Draft status, as indicated:
Document type:
Pagination:
vii, 66 p.
Related work(s):
The following parts of Section 11.6 appear in separate files:
Part A ; Part B ; Part C.
Pages added/changed by ARLIS:
Notes:
All reports in the Susitna-Watana Hydroelectric Project Document series include an ARLIS-
produced cover page and an ARLIS-assigned number for uniformity and citability. All reports
are posted online at http://www.arlis.org/resources/susitna-watana/
Susitna-Watana Hydroelectric Project
(FERC No. 14241)
Riparian Vegetation Study Downstream of the
Proposed Susitna-Watana Dam
Study Plan Section 11.6
Initial Study Report
Part A: Section 1-6, 8-10
Prepared for
Alaska Energy Authority
Prepared by
ABR, Inc.—Environmental Research & Services
June 2014
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page i June 2014
TABLE OF CONTENTS
1. Introduction ....................................................................................................................... 1
2. Study Objectives................................................................................................................ 2
3. Study Area ......................................................................................................................... 3
4. Methods and Variances in 2013 ....................................................................................... 3
4.1. Develop Mapping Materials from Historical and Current Data ............................. 4
4.1.1. Variances......................................................................................... 4
4.2. Field Surveys .......................................................................................................... 5
4.2.1. Plot Allocation Procedures ............................................................. 5
4.2.2. Floodplain Sediment Stratigraphy Study ........................................ 8
4.2.3. Surface Elevation ............................................................................ 9
4.2.4. Sampling of ITU Mapping Plots ..................................................... 9
4.2.5. Sampling of ELS Plots .................................................................. 10
4.3. ITU Classification and Mapping of Downstream Riparian Areas ........................ 12
4.3.1. ITU Classification ......................................................................... 12
4.3.2. ITU Mapping ................................................................................ 13
5. Results .............................................................................................................................. 15
5.1. Ecosystem Components ........................................................................................ 15
5.1.1. Geomorphic Units ......................................................................... 15
5.1.2. Surface Form ................................................................................. 16
5.1.3. Vegetation ..................................................................................... 16
5.1.4. Disturbance ................................................................................... 16
5.1.5. Poplar Size Class........................................................................... 16
5.1.6. Ecotypes ........................................................................................ 17
6. Discussion......................................................................................................................... 17
6.1. Ecosystem Components ........................................................................................ 18
6.1.1. Geomorphic Units ......................................................................... 18
6.1.2. Surface Form ................................................................................. 18
6.1.3. Vegetation ..................................................................................... 19
6.1.4. Disturbance ................................................................................... 19
6.1.5. Poplar size class ............................................................................ 19
6.1.6. Ecotypes ........................................................................................ 20
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page ii June 2014
6.2. Interrelated Studies ............................................................................................... 20
7. Completing the Study ..................................................................................................... 21
8. Literature Cited .............................................................................................................. 21
9. Tables ............................................................................................................................... 24
10. Figures .............................................................................................................................. 53
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page iii June 2014
List of Tables
Table 4.2-1. ELS Plots Allocated Randomly by Ecotype in Focus Area 104 (Whiskers
Slough), Middle Susitna River, Riparian Vegetation Study Area, Susitna-Watana
Hydroelectric Project, 2013.1 .................................................................................................25
Table 4.2-2. ELS Plots Allocated Randomly by Ecotype in Focus Area 115 (Slough 6A),
Middle Susitna River, Riparian Vegetation Study Area, Susitna-Watana
Hydroelectric Project, 2013.1 .................................................................................................26
Table 4.2-3. ELS Plots Allocated Randomly by Ecotype in Focus Area 128 (Slough 8A),
Middle Susitna River, Riparian Vegetation Study Area, Susitna-Watana
Hydroelectric Project, 2013.1 .................................................................................................27
Table 4.2-4. ELS Plots Allocated By Ecotype in Focus Areas (FAs) and Satellite Areas
(SAs), Middle Susitna River, Riparian Vegetation Study Area, Susitna-Watana
Hydroelectric Project, 2013. ..................................................................................................28
Table 4.3-1. Coding System for Classifying and Mapping Geomorphic Units, Surface
Forms, Vegetation, Disturbance, and Poplar Size Classes, Riparian Vegetation
Study, Susitna-Watana Hydroelectric Project, 2013. .............................................................30
Table 5-1. Areal Extent of Individual Integrated Terrain Unit Classes and Aggregated
Ecotype Classes in Focus Area 104 (Whiskers Slough), Middle Susitna River,
Riparian Vegetation Study Area, Susitna-Watana Hydroelectric Project, 2013.1 .................32
Table 5-2. Areal Extent of Individual Integrated Terrain Unit Classes and Aggregated
Ecotype Classes in Focus Area 115 (Slough 6A), Middle Susitna River, Riparian
Vegetation Study Area, Susitna-Watana Hydroelectric Project, 2013.1 ................................34
Table 5-3. Areal Extent of Individual Integrated Terrain Unit Classes and Aggregated
Ecotype Classes in Focus Area 128 (Slough 8A), Middle Susitna River, Riparian
Vegetation Study Area, Susitna-Watana Hydroelectric Project, 2013.1 ................................36
Table 5-4. Classification and Description of Geomorphic Units and Water Bodies in the
Middle Susitna River Portion of the Riparian Vegetation Study Area, Susitna-
Watana Hydroelectric Project, 2013. .....................................................................................38
Table 5-5. Classification and Description of Surface Form Classes in the Middle Susitna
River Portion of the Riparian Vegetation Study Area, Susitna-Watana Hydroelectric
Project, 2013. .........................................................................................................................41
Table 5-6. Classification and Description of Vegetation Classes in the Middle Susitna
River Portion of the Riparian Vegetation Study Area, Susitna-Watana Hydroelectric
Project, 2013. .........................................................................................................................43
Table 5-7. Classification and Description of Disturbance Classes in the Middle Susitna
River Portion of the Riparian Vegetation Study Area, Susitna-Watana Hydroelectric
Project, 2013. .........................................................................................................................47
Table 5-8. Classification and Description of Poplar Size Classes in the Middle Susitna
River Portion of the Riparian Vegetation Study Area, Susitna-Watana Hydroelectric
Project, 2013. .........................................................................................................................48
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page iv June 2014
Table 5.1-1. List of Preliminary Ecotypes Classified Using 2012 Field Data and Mapping
Data for FA-104 (Whiskers Slough), FA-115 (Slough 6A), and FA-128 (Slough
8A), Middle Susitna River, Riparian Vegetation Study Area, Susitna-Watana
Hydroelectric Project, 2013. ..................................................................................................49
Table 5.1-2. Classification and Description of Preliminary Ecotypes Identified in the
Middle Susitna River, Riparian Vegetation Study Area, Susitna-Watana
Hydroelectric Project, 2013. ..................................................................................................50
List of Figures
Figure 3-1. Study Area for the Riparian Vegetation Study, Susitna-Watana Hydroelectric
Project, 2013. .........................................................................................................................54
Figure 4.2-1. Middle Susitna River ELS and ITU Mapping Plot Locations, Riparian
Vegetation Study, Susitna-Watana Hydroelectric Project, 2013. ..........................................55
Figure 4.2-2. ELS and ITU Mapping Plot Locations in Focus Areas 104 (Whiskers
Slough), 115 (Slough 6A), and 128 (Slough 8A), including Sediment Core and
Trench Locations, Riparian Vegetation Study,Susitna-Watana Hydroelectric Project,
2013. .......................................................................................................................................56
Figure 4.2-3. ELS and ITU Mapping Plot Locations in the Lower Susitna River, Riparian
Vegetation Study, Susitna-Watana Hydroelectric Project, 2013. ..........................................57
Figure 4.3-1. Integrated Terrain Unit (ITU) Mapping Completed as of Q4 2013, Riparian
Vegetation Study, Susitna-Watana Hydroelectric Project, 2013. ..........................................59
Figure 4.3-2. Comparison of Two Types of Aerial Imagery Across Three Time Periods,
Including Late Spring/Early Summer 2011, Mid-Summer 2011, and Mid-Summer
2012 at Focus Areas 104 (Whiskers Slough) and 128 (Slough 6A), Middle Susitna
River, Riparian Vegetation Study, Susitna-Watana Hydroelectric Project, 2013. ................60
Figure 5-1. Maps of Geomorphic Units in Focus Areas 104 (Whiskers Slough), 115
(Slough 6A), and 128 (Slough 8A), Middle Susitna River, Riparian Vegetation
Study, Susitna-Watana Hydroelectric Project, 2013. .............................................................61
Figure 5-2. Maps of Surface Forms in Focus Areas 104 (Whiskers Slough), 115 (Slough
6A), and 128 (Slough 8A), Middle Susitna River, Riparian Vegetation Study,
Susitna-Watana Hydroelectric Project, 2013. ........................................................................62
Figure 5-3. Maps of Vegetation Classes in Focus Areas 104 (Whiskers Slough), 115
(Slough 6A), and 128 (Slough 8A), Middle Susitna River, Riparian Vegetation
Study, Susitna-Watana Hydroelectric Project, 2013. .............................................................63
Figure 5-4. Maps of Disturbance in Focus Areas 104 (Whiskers Slough), 115 (Slough
6A), and 128 (Slough 8A), Middle Susitna River, Riparian Vegetation Study,
Susitna-Watana Hydroelectric Project, 2013. ........................................................................64
Figure 5-5. Maps of Poplar Size Classes in Focus Areas 104 (Whiskers Slough), 115
(Slough 6A), and 128 (Slough 6A), Middle Susitna River, Riparian Vegetation
Study, Susitna-Watana Hydroelectric Project, 2013. .............................................................65
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page v June 2014
Figure 5-6. Maps of Preliminary Ecotype Classes in Focus Areas 104 (Whiskers Slough),
115 (Slough 6A), and 128 (Slough 8A), Middle Susitna River, Riparian Vegetation
Study, Susitna-Watana Hydroelectric Project, 2013. .............................................................66
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page vi June 2014
LIST OF ACRONYMS, ABBREVIATIONS, AND DEFINITIONS
Abbreviation Definition
ABR ABR, Inc.—Environmental Research & Services
ArcGIS Esri's geographic information system for mapping and analysis
AEA Alaska Energy Authority
AVC Alaska Vegetation Classification
CIR color infrared
cm Centimeter
DBH diameter breast height
ELS Ecological Land Survey
FA Focus Area
FERC Federal Energy Regulatory Commission
ft feet
GIS geographic information system
GPS global positioning system
GW/SW Riparian Groundwater/Surface Water
ha hectare
IFS Instream Flow Study
ILP Integrated Licensing Process
in Inch
ISR Initial Study Report
ITU Integrated Terrain Unit
LiDAR Light Detection and Ranging
m Meter
Mat-Su Matanuska Susitna
NRCS USDA Natural Resources Conservation Service
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page vii June 2014
Abbreviation Definition
NWI National Wetlands Inventory
PM&E protection, mitigation and enhancement
PRM Project River Mile
Project Susitna-Watana Hydroelectric Project No. 14241
Q1, Q2, Q3, Q4 first quarter, second quarter, third quarter, and fourth quarter of the annual year
Riparian IFS Riparian Vegetation, Riparian Instream Flow
RSP Revised Study Plan
RTK Real time kinematic
SPD study plan determination
TM Thematic Mapper
TWG Technical Workgroup
UAFAFES University of Alaska Fairbanks Agricultural and Forestry Experiment Station
UK United Kingdom
USDA United States Department of Agriculture
USGS United States Geological Survey
USR Updated Study Report
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 1 June 2014
1. INTRODUCTION
On December 14, 2012, Alaska Energy Authority (AEA) filed its Revised Study Plan (RSP) with
the Federal Energy Regulatory Commission (FERC) for the Susitna-Watana Hydroelectric
Project (FERC Project No. 14241), which included 58 individual study plans (AEA 2012).
Included within the RSP was the Riparian Vegetation Study Downstream of the Proposed
Susitna-Watana Dam, Section 11.6. In the Riparian Vegetation Study, local-scale riparian
ecosystems on the Susitna River downstream of the Project dam site will be characterized, and
models describing the natural successional pathways for riparian vegetation along the Susitna
River will be developed. This baseline information will be used to support the development of a
spatially-explicit model to predict potential changes in riparian vegetation due to Project effects
(to be developed in the Riparian Instream Flow Study [Riparian IFS]; see Initial Study Report
[ISR] Study 8.6).
On February 1, 2013, FERC staff issued its study plan determination (February 1 SPD) for 44 of
the 58 studies, approving 31 studies as filed and 13 with modifications. On April 1, 2013 FERC
issued its study plan determination (April 1 SPD) for the remaining 14 studies; approving one
study as filed and 13 with modifications. RSP Section 11.6 was one of the 13 approved with
modifications in the April 1 SPD; FERC recommended the following:
Sampling Scheme
We recommend that AEA consult with TWG [Technical Working Group] on the
sampling design for vegetation sampling within and outside the focus areas, and file no
later than June 30, 2013, the following information:
1) A detailed sampling design, including a schematic of the sampling scheme for each
focus area, the stratification factors, and basis for the number of plots within and
outside the focus areas.
2) Documentation of consultation with the TWG, including how its comments were
addressed.
Consultation on the interrelated Riparian Vegetation, Riparian Instream Flow (Riparian IFS) and
Riparian Groundwater/Surface Water (GW/SW) study plans was accomplished with TWG
representatives in two meetings, held on April 23, 2013 and June 6, 2013. Licensing participants
were provided the opportunity to address technical details and comments and concerns regarding
the study’s approaches and methods.
The Riparian Instream Flow, Groundwater, and Riparian Vegetation Studies FERC
Determination Response Technical Memorandum (Riparian/GW TM) (R2/GW/ABR 2013)
addresses FERC’s April 1 SPD request concerning sampling design and intensity for vegetation
sampling within and outside the Focus Areas (FAs). The Riparian/GW TM was filed with FERC
on July 1, 2013.
Following the first study season, FERC’s regulations for the Integrated Licensing Process (ILP)
require AEA to “prepare and file with the Commission an initial study report describing its
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 2 June 2014
overall progress in implementing the study plan and schedule and the data collected, including an
explanation of any variance from the study plan and schedule.” (18 CFR 5.15(c)(1)). This Initial
Study Report on the Riparian Vegetation Study Downstream of the Proposed Susitna-Watana
Dam (Riparian Vegetation Study ) has been prepared in accordance with FERC’s ILP regulations
and details AEA’s status in implementing the study, as set forth in the FERC-approved RSP and
as modified by FERC’s April 1 SPD (collectively referred to herein as the “Study Plan”).
2. STUDY OBJECTIVES
As established in the Study Plan, the overall goals of the Riparian Vegetation Study are to
prepare maps of existing, local-scale riparian ecosystems (riparian ecotypes), wetlands, and
wildlife habitat types in areas downstream from the proposed Project dam site; characterize
sedimentation, vegetation succession, and vegetation-soil-landscape relationships; and
coordinate with the Riparian IFS (Study 8.6) and other closely related studies to provide
complimentary data products to support the development of a spatially-explicit model to predict
potential changes to downstream riparian floodplain vegetation due to Project modifications of
flow, sedimentation, groundwater, and ice processes (to be developed in the Riparian IFS; see
Study 8.6). This multi-year study was initiated in 2012 and will be continued beyond 2013
through the next year of study. The mapping prepared in this study will be used, in the FERC
License Application to assess the impacts to riparian ecotypes, wetlands, and wildlife habitats
(see Study 10.19) in areas downstream from the Project dam site, and to develop possible
protection, mitigation, and enhancement (PM&E) measures to address any identified effects.
The specific objectives of the Riparian Vegetation Study are to:
• Classify, delineate, and map riparian ecotypes, wetlands, and wildlife habitats
downstream from the Watana Dam site;
• Characterize the role of erosion and sediment deposition in the formation of floodplain
surfaces, soils, and vegetation using a combination of soil stratigraphic descriptions, sieve
analysis, and several complimentary sediment dating techniques;
• Quantify and describe Susitna River riparian vegetation communities using a
combination of basic statistical summaries (e.g., basal area, density, stand age) and
multivariate statistical techniques (e.g., cluster analysis, ordination, sorted tables), which
will be used to develop of a series of conceptual models of floodplain vegetation
succession building from those developed by Helm and Collins (1997); and
• Coordinate closely in the implementation of the Riparian IFS (Study 8.6), Groundwater
Study (Study 7.5), Ice Processes in the Susitna River Study (Study 7.6), and Fluvial
Geomorphology Modeling below Watana Dam Study (Study 6.6) to provide necessary
and complimentary data, including vegetation successional models and mapping in
support of a spatially-explicit model (to be developed in the Riparian IFS; see Study 8.6)
to predict potential impacts to downstream riparian floodplain vegetation due to Project
alterations of existing conditions downstream of the Project dam site.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 3 June 2014
3. STUDY AREA
As established in the Study Plan, the Riparian Vegetation Study is being conducted in riparian
areas along the Susitna River below the proposed Project dam site, with the downstream and
lateral extents as described below.
The 2013 study area for the Riparian Vegetation Study is presented in Figure 3-1; this same
study area is being used for the Riparian IFS (Study 8.6), Fluvial Geomorphology Modeling
below Watana Dam Study (Study 6.6), and the Groundwater Study (Study 7.5). The study area
includes those riparian areas downstream of the Project dam site to a point at which the effects of
altered stage and flow effects expected in the Susitna River would not be ecologically significant
(i.e., the expected hydraulic alterations would be overridden by the input from other rivers and/or
the effects of tidal fluctuations from Cook Inlet). In RSP Section 11.6, the longitudinal extent of
the Riparian Vegetation Study area extended to river mile (PRM) 75 because existing
information at the time the RSP was prepared indicated that the hydraulic effects of the Project
below the Three Rivers Confluence at the Sunshine Gage (PRM 84) showed substantial
attenuation, although small hydraulic effects appeared to be detectable as far downstream as the
Susitna Station Gage (PRM 26). The final determination of how far downstream Project
operational effects would extend was not made until the results of the Open-water Flow Routing
Model (see Study 8.5) were completed. Following the completion of the Open-water Flow
Routing Model in Q1 2013, a TWG meeting was held to discuss the selection of (FAs) and study
sites, which included discussion of the downstream extent of the study area for the riparian
studies. During the TWG meeting, it was agreed that the downstream extent of the study areas
for the riparian studies, including the Riparian Vegetation Study, would extend to Project River
Mile (PRM) 29.5 (R2 2013). Figure 3-1 shows the study area boundary of the Riparian
Vegetation Study extended downstream to PRM 29.5
For the 2013 work, the lateral extent of the Riparian Vegetation Study area was defined by the
extent of the riverine physiographic region generated by the Susitna River. Riverine
physiography includes (1) those areas of the valley bottom, including off-channel water bodies,
that are directly influenced by regular (0–25 year) to irregular (25–100 year) overbank flooding;
and (2) those areas of the valley bottom influenced indirectly by groundwater associated with the
Susitna River. In 2012, riverine physiography was mapped by the Riparian Vegetation Study
team from the Project dam site to PRM 29.5 (Figure 3-1) by interpretation of image-signatures
on high-resolution aerial imagery for the Susitna River. The riverine physiographic map has
undergone review and refinement by the principal investigators leading the Riparian Vegetation
Study, the Riparian IFS (Study 8.6), and associated physical-processes studies (groundwater
[Study 7.5], ice processes [Study 7.6], and fluvial geomorphology [Study 6.6]). After review by
the agencies, a final riverine physiography layer will be prepared for use as the lateral boundary
of the Riparian Vegetation Study in the next year of study.
4. METHODS AND VARIANCES IN 2013
This study involves the use of Integrated Terrain Unit (ITU) mapping, which is an integrated
approach to mapping landscape elements. ITU mapping is a multivariate mapping process in
which terrain unit map boundaries are adjusted by on-screen digitizing over high-resolution
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 4 June 2014
aerial photography or satellite imagery so that there is increased coincidence between the
boundaries and occurrences of interdependent ITU variables, such as hydrography, geology,
physiography, soils, and vegetation units (Jorgenson et al. 2003; 2009). The ITU approach being
used to map riparian ecotypes, wetlands, and wildlife habitats is based on methods and concepts
developed for Ecological Land Survey (ELS) studies conducted in tundra, boreal forest, and
coastal regions in Alaska over the past 15 years (see Jorgenson et al. 2003 for an example study
in Southcentral Alaska). The ITU mapping approach for the Riparian Vegetation Study involves
mapping terrain units such as vegetation type, balsam poplar size class (e.g., pole, timber, large
timber), fluvial geomorphology, and surface-form types . These map data are being combined
into units with ecological importance (in this case riparian ecotypes, wetlands, and wildlife
habitats). Also based on previous ELS studies in Alaska, a set of field plots are being sampled to
collect detailed data on site characteristics, environmental variables, successional vegetation, and
soils; a subset of the field plots also are designed for use as permanent, long-term monitoring
plots (see Section 4.2.5, Sampling of ELS Plots, below).
For this study, a series of maps will be produced, including maps of the individual terrain units
(i.e., geomorphology, surface form, vegetation type, poplar size class), and maps of the
aggregated terrain units (i.e., riparian ecotype, wetlands, and wildlife habitat). The mapping of
wildlife habitats in the Riparian Vegetation Study is being conducted in coordination with the
vegetation and wildlife habitat mapping study (Study 11.5) to derive a seamless map of wildlife
habitats that apply Project-wide. Similarly, the mapping of wetlands is being conducted in
coordination with the wetland mapping study (Study 11.7) so that wetlands in the Riparian
Vegetation Study area can be similarly classified and are compatible with the wetland types
mapped in the Cook Inlet Basin wetlands classification system (Gracz 2011); this will result in a
single Project-wide wetland map.
4.1. Develop Mapping Materials from Historical and Current Data
The methods for developing mapping materials were implemented as described in the Study Plan
with no variances. Data sources being used for the mapping of riparian ecotypes and wildlife
habitats include vegetation mapping and vegetation succession studies conducted in the Susitna
River drainage by McKendrick et al. (1982), UAFAFES (1985), Collins and Helm (1997), Helm
and Collins (1997). For wetlands, digital National Wetlands Inventory (NWI) data for the study
area, which was developed in the 1980s, is available. Additional data include digital elevation
data and the National Hydrography Dataset (USGS 1999). These data have been compiled and
reviewed and are being used as map layers in a geographic information system (ArcGIS) to assist
the mapping efforts.
The available, high- and moderate-resolution aerial imagery for the project area also has been
acquired for use in the mapping effort. Additional recent and high-resolution aerial imagery,
which is needed to complete the mapping in this multi-year study, is expected to be available in
late 2013.
4.1.1. Variances
There were no variances from the protocols described in the Study Plan to develop mapping
materials from historical and current data.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 5 June 2014
4.2. Field Surveys
The methods for the field surveys were implemented as described in the Study Plan with the
exception of the variances explained below (see Sections 4.2.1.3 and 4.2.5.1). While land-access
permits were not available for Cook Inlet Regional Working Group (CIRWG) lands for field
surveys in 2013, this did not affect the study implementation and was not considered a variance
because, as described in the Study Plan (Sections 11.6.1 and 11.6.6), the study design indicates
that the entire study area will be surveyed and mapped sequentially over multiple years. In 2013,
field surveys were conducted downstream of CIRWG lands, and in the final year of the study,
assuming access is authorized, field surveys will be conducted upstream on CIRWG lands.
In 2013, field sampling was conducted during three periods, with sampling conducted in the
Middle and Lower Susitna River (Figures 4.2-1 through 4.2-3). During the first period (May 19–
22), the Riparian Vegetation Study and Riparian IFS (Study 8.6) study teams sampled sediment
stratigraphy trenches at FA-104 (Whiskers Slough) (Figure 4.2-2) to refine the methodology for
sampling soil stratigraphy and collecting soil cores for sieve analysis and sediment dating.
Following that first field survey, it was concluded that the soil sampling methods for sediment
dating required further review. During the months of June, July, and August, the Riparian
Vegetation Study team worked collaboratively with the Riparian IFS (Study 8.6) team to revise
and implement the field methods for sampling soils for sediment dating.
During the second and third field survey periods (June 17–July 10 and July 24–August 12,
respectively), the sampling was focused on four study components: (1) ELS plots were sampled
within the FAs in coordination with the study teams from the Riparian IFS (Study 8.6) and
Groundwater Study (Study 7.5), (2) ITU mapping plots were surveyed along transects in the
broader study area (i.e., outside FAs) to rapidly collect field-verification data to further refine the
riparian ecotype classes and provide ground-reference data for verification of the ITU mapping
in the Lower River (planned to commence in 2014), (3) ELS plots were sampled in the broader
study area to supplement the data for rare vegetation types in the FAs and facilitate the scaling-
up of the results from the FAs, and (4) rates of sedimentation across the Susitna River floodplain
were quantified using field stratigraphic descriptions, sediment cores, and standard laboratory
sediment dating methods. The sampling procedures and methods for each of the above
components of the riparian vegetation surveys are provided below.
4.2.1. Plot Allocation Procedures
4.2.1.1. ELS Plots
The ELS plot allocation procedures were implemented as described in the Study Plan with the
exception of the variances explained below (see Section 4.2.1.3). The preliminary ITU mapping
of riparian ecotypes prepared in 2012was used to design a stratified random sampling procedure
to preselect ELS study plots within the FAs.
A stratified random sample design was developed for riparian FA-104 (Whiskers Slough), FA-
115 (Slough 6A), and FA-128 (Slough 8A) using riparian ecotype as the sampling stratum
(Figure 4.2-2 and Figure 4.2-4). (Plot allocation and sampling of plots in areas upstream of FA-
128 [Slough 8A] is planned for the next year of study.) In the stratification procedure, the 2012
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 6 June 2014
ITU mapping first was clipped, using ArcGIS, to the boundary of each FA. The total number of
ecotypes within a FA and the total area (acres) of each ecotype within a FA was then calculated.
The total minimum number of random plots per FA was determined using the following formula
as a guide:
# FA plots=1 plot/ 20 acres + 1.5*the total # of terrestrial ecotypes in a FA
The above formula accounts for both total area of a FA and the total number of ecotypes, such
that a smaller FA with a high number of ecotypes would be assigned a larger number plots than
if it would be based on area alone. The total area of each ecotype was then divided by the total
area of the respective FA to determine the percent area of each ecotype within each FA.
Ecotypes encompassing ≥ 2% of the total area within a FA were assigned a minimum number of
random plots using the following formula as a guide:
# random plots per ecotype = % of total terrestrial ecotype area*# of FA plots
To ensure that the less common ecotypes would not be under-sampled, the results from the above
formula were used to decrease (by 2–7 plots) the final number of plots per ecotype for the largest
ecotypes in a FA and to increase slightly (by 1–3 plots) the final number of plots per ecotype for
smaller ecotypes, particularly herbaceous ecotypes, in a FA. The number of ELS plots allocated
by ecotype in each of the three FAs sampled in 2013 using this stratified random selection
procedure is presented in Tables 4.2-1 through 4.2-3.
Once the number of plots per ecotype within a FA was determined, the GENERATE RANDOM
POINTS TOOL from Hawth's Analysis Tools for ArcGIS
(http://www.spatialecology.com/htools/rndpnts.php) was used to generate the locations of the
random plots in the map polygons for each ecotype. Then once the random plot locations were
generated, a 23-m (75-ft) buffer (plot radius) was created around each plot for review. The
buffered points were reviewed by a GIS analyst over high-resolution aerial imagery mosaics in
ArcGIS to ensure that each plot was located entirely within an ecotype. Plots where the 23-m
(75-ft) radius circular plot was not located entirely within an ecotype were either (1) adjusted by
hand slightly (< 25 m [82-ft]) to place the plot entirely within the target ecotype, or (2) were
assigned an alternative plot shape of the same total area as the 23-m (75-ft) radius plot (e.g., long
narrow riparian landforms required more elliptical-shaped plots). This plot reshaping was
essential since riparian landforms are inherently narrow and often small and oddly shaped.
For those ecotypes that are uncommon or do not occur in FAs (to include herbaceous vegetation
types), ELS plots were added in Satellite Areas outside of FAs to increase the total number of
samples collected in those ecotypes that are under-represented in FAs (Table 4.2-4, Figure 4.2-
1). For herbaceous vegetation types , a target of sampling at least 75% of the ecotype polygons of
each of the herbaceous ecotypes was established. For all other ecotypes that are under-
represented within FAs, 1 to 3 plots were added to increase the total sample size across the entire
Middle River to at least 3 ELS plots per ecotype. To increase efficiency in the field, Satellite
Area plots of different ecotypes were chosen such that they were clustered together spatially,
typically within a 1-mi radius of other plots within that Satellite Area. Satellite Areas in 2013
were spaced such that they spanned the entire length of the Middle River from Gold Creek to the
Three Rivers Confluence. ELS plot locations were selected in Satellite Areas to represent
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 7 June 2014
relatively homogeneous vegetation in selected ecotypes as determined from high-resolution
imagery.
During the second and third field survey periods, a total of 28, 23, and 4 ELS plots were
sampled, respectively, in FA-104 (Whiskers Slough), FA-115 (Slough 6A), and FA-128 (Slough
8A) (Figures 4.2-1 and 4.2-2). In Satellite Areas, a total of five ELS plots were sampled (Figure
4.2-1).The total number of ELS plots sampled by ecotype in each FA and within Satellite Areas
in 2013 are presented in Tables 4.2-1 through 4.2-4. The remaining allocated plots will be
surveyed during the field season of the next year of study.
4.2.1.2. ITU Mapping Plots
The methods for allocating ITU mapping plots in the study area were implemented as described
in the Study Plan with no variances. During the 2013 field season, ITU mapping plots were
sampled primarily in the Lower River (i.e., Three Rivers Confluence and areas downstream).
ITU mapping plots were grouped spatially into transects and those transects were placed in areas
that featured a diversity of different vegetation types and environments within a relatively short
distance to one another. For the Lower River, which is not covered by the 2012 preliminary
mapping, ITU plot locations were selected along transects to represent relatively homogeneous
vegetation as determined from high-resolution imagery. Additional ancillary GIS data also were
used to aid in selection ITU plot locations, including riparian process domains and LiDAR
elevation data, and interpretation of image-signatures on aerial imagery for the Lower River.
In the Middle River in 2013, ITU mapping plots were used to (1) target areas on the 2012 ITU
mapping that were identified during the mapping process as requiring more field data for
verification, and (2) co-locate plots adjacent to groundwater well installations at FA-128 (Slough
8A).
In 2013, 191 ITU mapping plots were sampled in the Lower River (Figure 4.2-3), and 26 in the
Middle River (Figures4.2-1 and 4.2-2).
4.2.1.3. Variances
The original plot-allocation procedure described in the Study Plan specified the sampling of ELS
plots in FAs based on the size of the FAs alone (a sampling rate of 1 ELS plot per 10 acres for
FAs up to 200 acres in size, and a maximum of 20 plots for FAs > 200 acres). This procedure
had to be altered because the Study Plan was completed before the boundaries of the FAs were
fully defined, and, upon finalization of the FA boundaries, it was determined that all FAs were >
250 acres. As agreed to in the TWG process, the plot-allocation procedure was modified to
adjust for this and ELS plots were allocated based both upon the size of each FA and the number
of ecotypes in each FA as described above. This revised procedure provided for a higher number
of plots being assigned to each FA than would have occurred under the original sampling scheme
(see R2 2013). Additionally, those ecotypes that were under sampled in FAs were sampled with
additional ELS plots in Satellite Areas to increase the sampling of underrepresented ecotypes.
The sampling of each FA (and the Satellite Areas) now is more intensive, which will result in
more accurate information on vegetation structure and composition in each FA and throughout
the study area. Additional field data also will be available to use to describe each ecotype in the
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 8 June 2014
study area. This increased sampling will serve to better meet the study objectives and no
additional modifications are needed to the ELS plot-allocation process to complete the study.
4.2.2. Floodplain Sediment Stratigraphy Study
The field methods for the floodplain sediment stratigraphy study were implemented as described
in the Study Plan with no variances. In support of the Riparian IFS (Study 8.6) floodplain-
erosion and sediment-deposition analyses (see RSP Section 8.6.3.5), floodplain sediment
stratigraphy was characterized using both soil trenches and sediment core techniques. The
objective of the sediment stratigraphy study is to characterize the role of erosion and sediment
deposition in the formation of floodplain surfaces, soils, and vegetation (see RSP Section
8.6.3.5). The collaborative field effort for this study was conducted by the study teams for the
Riparian Vegetation Study and Riparian IFS (Study 8.6).
To quantify floodplain sediment deposition over the last century, two tasks were undertaken: (1)
two exploratory soil trenches were excavated to characterize floodplain sediment stratigraphy
and grain-size distribution, and (2) 13 sediment core samples were taken for analysis of 210Pb and 137Cs soil isotope geochronology (for direct dating of fluvial sediments).
Floodplain stratigraphy was assessed at two ELS plot at FA-104 (Whiskers Slough) (Figure 4.2-
2). The trenches were placed in the 3-m (10-ft) trample zone at the plot center. Floodplain soil
trenches were excavated from the floodplain surface to the gravel/cobble layer (historic channel
bed). Soil materials extracted from the trenches were placed on tarps to protect the soil surface
and increase efficiency in replacing the soil material when the sampling was complete. Soil
profile and stratigraphy were measured and described using standard NRCS field techniques
(Schoeneberger et al. 2012). Sediment samples were taken at all major horizons for sediment
grain-size sieve analysis (USDA NRCS 2004).
Sediment cores were collected during 2013 at 13 locations in the Middle River, 5 at FA-104
(Whiskers Slough) and 8 at FA-115 (Slough 6A) (Figure 4.2-2). At both FA-104 (Whiskers
Slough) and FA-115 (Slough 6A), sediment sample sites were located at ELS plot locations
along transects perpendicular to the river (Figure 4.2-2). Topographic transects and plot locations
were surveyed using real time kinematic (RTK) GPS survey instrumentation tied into the Project
elevation datum (see Section 4.3.4, below). Sediment cores were collected with a 91-cm length x
2.5-cm diameter thin-walled soil probe (AMS Inc.). Recovery of sediment cores was generally
excellent, and the longest cores (typically 60–130 cm depending on depth to the cobble/gravel
refusal layer) were selected for 210Pb and 137Cs analysis.
The laboratory geochronology analyses for 210Pb and 137Cs will be conducted at the Department
of Geography, University of Exeter, UK, using standard methods (Aalto 2003; Aalto et al. 2008).
Selected sediment cores will be sectioned at 2-cm intervals for both particle-size and isotope
analyses. Sediment isotope laboratory results from the 2013 soil cores will be used to evaluate
the sediment geochronology methods and determine the appropriate design for the sediment
stratigraphy study to be conducted during the next year of study (see RSP Section 8.6.3.5).
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 9 June 2014
4.2.2.1. Variances
There were no variances from the methods described in the Study Plan for the floodplain
sediment stratigraphy study.
4.2.3. Surface Elevation
The field methods for collecting surface elevation data were implemented as described in the
Study Plan with no variances. Ground surface elevation was recorded at all ELS plot centers,
including those in FAs and those in the broader study area in coordination with the Fish and
Aquatics Instream Flow Study (Study 8.5) and Riparian IFS (Study 8.6) field teams. Elevation
surveying was conducted in the following manner. Plot centers were surveyed in by Riparian IFS
field teams using a transit (elevation) and GPS unit (latitude/longitude). Transit surveys were tied
into an intermediate benchmark established at each FA and ELS transect (e.g., a nail in a tree
near riverbank). The flow-routing field team then surveyed the intermediate benchmark using an
RTK survey instrument to tie the riparian survey plot elevations into the Project elevation datum.
4.2.3.1. Variances
There were no variances from the methods for collecting surface elevation data as described in
the Study Plan.
4.2.4. Sampling of ITU Mapping Plots
The field methods for the sampling of ITU mapping plots were implemented as described in the
Study Plan with no variances. The ITU mapping plots are designed to facilitate the rapid
collection of data for the variables used in the ecotype classification and ITU mapping process.
The methods are designed for efficiency in the field in order to cover a large area in a relatively
short amount of time (typically 5–8 ITU mapping plots/field team are completed in a day).
Transects for the ITU plots were oriented more or less perpendicular to the Susitna River channel
so as to cross various floodplain surfaces and patches of riparian vegetation in different
successional stages. Five to 10 circular plots of 10-m (33-ft) radii were sampled along each
transect, each on a distinct floodplain surface and in a distinct vegetation type. The shape of the
ITU mapping plots varied depending on the shape of the vegetation stand being sampled (e.g.,
long narrow stands of willow required a more elliptical-shaped plot). However, the same
absolute area was sampled on all plots. All field data were recorded digitally in the field using a
standardized data entry form on an Android tablet computer designed to link directly to a
relational database (Microsoft Access). The following variables were recorded at each ITU
mapping plot:
• Geo-referenced plot location (< 3-m [10-ft] accuracy);
• Site variables, including physiography, geomorphic unit, surface form, elevation, aspect,
and slope;
• Vegetation structure, plant community composition, and plant percent-cove data to
classify vegetation types to Level IV of the Alaska Vegetation Classification (AVC)
(Viereck et al. 1992);
• Shallow soil pits were dug to categorize drainage and soil moisture;
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 10 June 2014
• Soil hydrologic variables, including depth of water above or below ground surface, depth
to saturated soil, pH, and electrical conductivity (EC);
• Soil depositional profiles;
• Wildlife sign such as winter or summer browse marks, nests, dens, droppings, singing
birds, carcasses, tracks, and burrows; and
• Locations of tree ice-scars, ice bull-dozing, or other evidence of disturbance by ice (e.g.,
ice rafted boulders) were recorded at each plot and along each transect, for use in the Ice
Processes in the Susitna River Study (Study 7.6) and the Riparian IFS (Study 8.6).
4.2.4.1. Variances
There were no variances from the sampling methods for ITU mapping plots as described in the
Study Plan.
4.2.5. Sampling of ELS Plots
The field methods for the sampling of ELS plots were implemented as described in the Study
Plan with the exception of the variances explained below (see Section 4.2.5.1). The ELS plots,
are being used to collect data on site and environmental variables (following Jorgenson et al.
2009); vegetation composition (abundance and richness) and structure (size class, density, age);
as well as detailed soil characteristics (see Soil Sampling and Sediment Aging, below). The
purpose of the ELS plots is two-fold. First, the ELS plots are designed to facilitate the collection
of detailed data on existing conditions (site characteristics, environmental variables, vegetation,
and soils) for use in floristic, ecotype, and habitat analyses; sediment stratigraphy, aging, and
sieve analyses; and the development of vegetation successional models. Second, the ELS plots
and methods are designed to provide baseline data for a possible long-term monitoring study,
with emphasis on repeatability of methods and relocation of plots, for use in potential future
studies of changes in riparian vegetation due to Project operations. Due to the dual purpose of
ELS plots and the need for repeatability, the field sampling protocols for ELS plots are more
intensive than ITU mapping plots, making the ELS plots more time consuming to sample than
the ITU mapping plots (typically 1–2 ELS plots/day can be completed by a field team).
ELS plots were designed following a nested, variable-sized-plot approach as illustrated in Figure
4.2-4.The variable-sized-plot design included a plot center, 3 nested tree/shrub plots, and a larger
point-intercept plot. The plot center (3-m [10 ft] radius) served as a trample zone in which no
vegetation sampling occurred. A 5.56-m (18 ft) radius plot was used to record species and
Diameter at Breast Height (DBH) of all trees and selected shrubs (Alnus spp., Salix spp.) with a
DBH < 5 cm(2 in). For any shrubs with multi-stem clusters from a single individual, stems were
counted and a note was made to indicate that stems were of a single individual. For saplings and
shrubs < 5 cm (2 in) DBH, diameter was recorded in 5 size classes (< 1, 1–2, 2–3, 3–4, and 4–5
cm [< 0.4, 0.4-0.8, 0.8-1.2, 1.2-1.6, and 1.6-2 in, respectively]). An 11.28-m (37 ft) radius plot
was used to record species and DBH to the nearest 0.1cm (0.04 in) for all trees with a DBH of ≥
5 cm (2 in). Two trees of each species within this zone were aged using increment cores (2 per
tree) extracted near the root collar. In plot locations where no trees with DBH ≥ 5 cm (2 in) were
present, each shrub and/or sapling species was aged using increment cores (2 per species for
trees > 4–5 cm [1.6-2.0 in] DBH) or cookies (2 per species For shrubs and trees < 4 cm [1.6 in]
DBH); both increment cores and cookies were extracted near the root collar. The vertical
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 11 June 2014
distance from the root collar to the core/cookie location and the depth of sedimentation above the
root collar to the floodplain surface was measured. A 16.25-m (53.3 ft) radius plot was used to
record DBH and species (if recognizable) of dead standing snags. Snags were considered to be
any dead tree or shrub with DBH ≥ 5 cm (2 in) and ≥ 1.5 m (4.9 ft) in height. A 23-m (75 ft)
radius plot was used to collect data on vegetation structure, plant community composition, and
plant cover using the line-intercept method. For those ELS plots along groundwater transects, the
groundwater instrumentation was co-located with ELS plots whenever possible, and was placed
just outside the 23-m (75 ft) outer boundary of each ELS plot.
Each 23-m (75 ft) radius ELS plot was divided into four quadrants using 50-m (164-ft)
measuring tapes, which served as vegetation sampling lines for the point-intercept measurements
of all herbaceous and shrub species, and densiometer measurements of tree species. The
orientation of the lines was determined from a random initial compass bearing to orient the first
line. The remaining lines were oriented at 90 degree intervals to each other. Along each line,
point-intercept measurements were recorded at 1-m (3.3-ft) increments along the measuring tape,
beginning at 4 m (13 ft) (i.e., 1 m [3.3 ft] past the boundary of the trample zone) and ending at 23
m (75 ft) for a total 20 points per line. An additional five points per plot quadrant were sampled
randomly off the tape lines within each quadrant. Therefore, for each plot, 80 points were
recorded on the sampling lines, and 20 points off-line for a total of 100 points. At each point, a
laser point (GreenBeam 50) and densitometer (Geographic Resource Solutions™) mounted on an
extendable painters pole were used to collect point-intercept data (species hits) from the ground
surface to the tree canopy. All hits of each plant species by the laser were tallied in two height
classes (0–1.5 and 1.5–3 m [0–4.9 ft and 4.9–9.8ft, respectively]). The laser was oriented
upwards to detect hits in the 1.5–3.0 m (4.9–9.8 ft) class. The densitometer was used to record
the presence of trees and shrubs taller than 3 m (10 ft) (i.e., forest canopy). In addition to
vascular plant species, hits of several categories of mosses (feather moss, Sphagnum spp., and
other mosses), lichens (foliose, fruticose, crustose), and bare ground (rock, bare soil, litter, water)
were also recorded.
Once transect sampling was completed, a random wander through the plot area was conducted to
record the presence of any vascular plant species not previously recorded on the point-intercept
transects. The random wander continued until 10 minutes had passed since a new species had
been recorded. Soil pits were located in a randomly selected quadrant at approximately 12 m (39
ft) from the plot center point and half way between the two adjacent vegetation sampling lines.
Landscape photographs were taken from the plot center looking out along each vegetation
sampling line.
Additional sampling details and data recorded included:
• Plot center and sampling line end-point locations (latitude/longitude), were recorded
using Trimble GeoXT GPS units (≤ 1-m [3.3 ft] accuracy);
• Permanent magnetic survey markers (SurvKap®) were buried at approximately 20 cm (8
in) depth at the plot center point to aid in relocating these plots in the future;
• Site variables, including physiography, geomorphic unit, surface form, elevation, aspect,
and slope;
• Vegetation types, classified in the field, to Level IV of the AVC (Viereck et al. 1992);
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 12 June 2014
• Wildlife sign such as winter or summer browse marks, nests, dens, droppings, singing
birds, carcasses, tracks, and burrows;
• Locations of tree ice-scars, ice bull-dozing, or other evidence of disturbance by ice (e.g.,
ice rafted boulders) were recorded at each plot and while traversing to the next plot, for
use in the Ice Processes in the Susitna River Study (Study 7.6) and the Riparian IFS
(Study 8.6) studies.
All field data were recorded digitally in the field using a standardized data entry form on an
Android tablet computer designed to link directly to a relational database (PostgreSQL).
4.2.5.1. Variances
In 2013, two variances from the ELS sampling methods as described in the Study Plan were
made and implemented. First, the original point-intercept sampling interval of 0.5 m (1.6 ft)
described in the Study Plan for vegetation sampling on the ELS plots was changed to a 1.0-m
(3.3 ft) interval; this change allowed for more accurate and representative data collection (less
overlap in recording the same plants) in the dense, multi-canopied vegetation characteristic of the
Susitna River floodplain. The larger sampling interval necessitated a larger sampling radius (23
m [75 ft]) for the ELS plots.
Second, for those ELS plots along groundwater transects, due to the large size of the
groundwater installation hardware relative to the 3-m (10 ft) ELS plot center, and to reduce the
risk of vegetation disturbance within the plot boundaries, the groundwater installation was not
co-located with the ELS plot center as described in the Study Plan. Rather, the instrumentation
was placed adjacent to the plot just outside the 23 m (75 ft) outer boundary of each ELS plot.
The increased point-intercept sampling interval facilitated more accurate collection of field data,
and the location of groundwater instrumentation outside of the ELS plots reduced vegetation
disturbance on the ELS plots (preserving the plots utility for possible long-term monitoring
studies). Both of these variances served to better fulfill the study objectives and there are no
additional modifications needed for 2014 for the sampling of ELS plots.
4.3. ITU Classification and Mapping of Downstream Riparian Areas
4.3.1. ITU Classification
The methods for ITU classification were implemented as described in the Study Plan with no
variances. Ecosystems in the study area were classified at two levels. First, individual ecosystem
components (ITU variables) were classified and coded in the field using standard classification
systems developed by ABR for Alaska (Table 4.3-1). Second, the ecosystem components were
integrated to classify a set of preliminary riparian ecotypes (local-scale riparian ecosystems) that
best partitioned the range of variation observed for all measured components.
Geomorphic units were classified according to a system based on landform and soil
characteristics for Alaska; this system was developed originally by Kreig and Reger (1982) and
ADGGS (1983) and was modified for previous work in Southcentral Alaska by Jorgenson et al.,
(2003). In classifying and mapping geomorphic units, materials near the surface (< 1 m deep)
were emphasized because they have more influence on ecological processes than do materials
deeper in the soil/substrate profile. For example, when mapping alluvial deposits, channel and
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 13 June 2014
overbank deposits were differentiated based on the differences in fluvial processes involved in
creating and maintaining these surfaces. Similarly, three different types of overbank deposit
(active, inactive, abandoned) were differentiated based on flooding frequency. Surface forms
(macrotopography) were classified according to a system modified from that of Schoeneberger et
al. (2012). Microtopography was classified according to the periglacial system of Washburn
(1973). Vegetation was classified using Level IV types of the AVC developed by Viereck et al.
(1992), with adjustments as needed for successional vegetation following Helm and Collins
(1997).
The 2012 field data and the ITU mapping data were used to prepare a preliminary riparian
ecotype classification for the Middle River portion of the Riparian Vegetation Study area. First,
ecotypes were classified using contingency tables to establish common relationships among
ecosystem components from the field data. Ecotype classes then were derived from a set of 215
unique ITU code combinations (from the full extent of the ITU mapping in the study area) by
aggregating into a set of 20 ecotypes, and a crosswalk was created between the ecotype classes
and the ITU combinations. The crosswalk was used to create a tabular join in ArcGIS and the
ITU map data were then recoded to create an ecotype map class. In cross-walking the combined
ecosystem components to ecotype classes, an attempt was made to use those ecological
characteristics (primarily geomorphology, surface form, and vegetation structure) that could be
readily interpreted from aerial imagery. The number of potential ecotype classes (215) was
reduced by aggregating the field data for individual ecological characteristics (e.g., soil
stratigraphy and vegetation composition) into more generalized classes. For geomorphology
classes, soil profiles were generalized by aggregating soil horizons with similar textures and bed
forms into geomorphic units using the approaches of Miall (1985). Geomorphic units were
assigned to physiographic settings based on their erosional or depositional processes. Surface
forms were aggregated into a reduced set of elements (primarily driven by ecological processes,
including sedimentation, erosion, ice scour, and wind disturbance). For vegetation, the structural
components of the AVC Level IV classes of Viereck et al. (1992) were emphasized, because
vegetation structure is readily identifiable on aerial photographs.
In addition to the 20 ecotypes determined from the 2012 field data, map data from FA-104
(Whiskers Slough), FA-115 (Slough 6A), and FA-128 (Slough 8A) (see Section 5.1.6 below)
also were used to develop another nine temporary ecotype classes, which will be assessed further
in the next year of study with analyses of the 2013 field data. Ecotype names were based on the
aggregated ecosystem components, including physiography, dominant soil texture, and
vegetation composition and structure (e.g., Riverine Sandy Pole-sized Balsam Poplar Forest).
4.3.2. ITU Mapping
The methods for ITU mapping were implemented as described in the Study Plan with no
variances. As noted above in Section 4.1, Overview, in this study riparian ecotypes, wetlands,
and wildlife habitats are being mapped using an ITU approach. All the mapping of riparian areas
is being conducted on-screen in ArcGIS and extensive use of the field ground-reference data is
being made so that image-signatures are accurately interpreted. A minimum mapping size of
0.40 ha (1 acre) for terrestrial polygons and 0.10 ha (0.25 acres) for water bodies is being used.
Individual ecosystem components or ITU variables were mapped concurrently and were
identified by assigning a five-parameter, compound code to each polygon describing
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 14 June 2014
geomorphology (e.g., Braided Active Channel Deposit, Fbra); surface form (e.g., Mid-channel
Bar, Fbm); vegetation class (e.g., Open Balsam Poplar Forest, Fbop), poplar size class (e.g.,
Pole, P), and disturbance class variables (e.g., Ice Bulldozing, Ngi) (Table 4.3-1). The five map
components, when combined, represent unique ITUs (e.g., Fbra/Fbm/Fbop/P/Ngi). Following
mapping, the compound ITU classes were aggregated to preliminary riparian ecotypes based on
the combination of ITUs that best represents the local-scale riparian habitats in the mapped areas.
In 2012 and 2013, ITU mapping of riparian ecotypes in the Middle Susitna River was carried out
by image-interpretation of the current aerial imagery available for the study area. Ground-
reference data collected in summer 2012 and 2013 was used to verify the mapping. For this
preliminary mapping effort, the mapping was limited to those areas delineated as riverine
physiography (see Section 3, Study Area, above) and which are covered by the Matanuska-
Susitna Borough (Mat-Su) true color and color infrared (CIR) orthophoto aerial imagery
collected in mid- to late summer 2011 (upstream of PRM 121); this imagery provides the best
color signatures for mapping since the imagery in these areas was collected at full vegetation
green-up (Figure 4.3-1). Color signatures in areas of the Mat-Su aerial imagery collected in late
spring/early summer are not consistent with the mid- to late summer imagery as the former areas
were collected prior to full vegetation green-up, making consistent and accurate interpretation of
image signatures across the entire study area difficult (Figure 4.3-2). Despite these shortcomings,
the Mat-Su aerial imagery collected in late spring/early summer was the only high-resolution (≤
1 m) imagery available in Q2 2013 that encompassed FA-104 (Whiskers Slough) and FA-115
(Slough 6A) (which are located downstream of river mile 121). This imagery was used as the
base layer over which the mapping of riparian ecotypes in FA-104 (Whiskers Slough) and FA-
115 (Slough 6A) was conducted (Figure 4.3-1). The resulting ecotype mapping was essential for
use in developing the stratified random sampling design for those FAs, as described in Section
4.3.1, Plot Allocation Procedures, above.
In Q2 2013, the processing of the 2012 mid-summer Susitna High Flow CIR imagery was
completed. Initially, the color signature was oversaturated, making it difficult to interpret color
signatures between different vegetation types. In Q3 2013, the 2012 Susitna High Flow CIR
imagery was rebalanced. The rebalanced imagery became available in early Q4 2013 and
represents a significant improvement so that it now compares in quality to the 2011 mid-summer
Mat-Su aerial imagery. However, the 2012 imagery only covers the riparian study area between
PRM 63 to 119 (Figure 4.3-2). While the 2012 imagery fills a large and important gap in mid-
summer, high-resolution imagery across the riparian study area, there are still two gaps in mid-
summer, high-resolution imagery (PRM 119 to 121 and PRM 29.5 to 63). Notwithstanding the
caveats noted above in using imagery collected outside of the mid-summer period, going forward
the Riparian Vegetation Study team will rely on two sets of existing imagery that cover different
portions of those two identified gaps in imagery (the high-resolution 2011 Mat-Su late
spring/early summer and the coarser 2004 Mat-Su mid-summer imagery); in Q1 2014, the study
team also will search the imagery archives for additional mid-summer imagery that may have
been collected in recent years in those areas. Only after all sources of existing imagery are
evaluated and, if they are found unsatisfactory, will discussions with AEA occur regarding the
potential for collecting additional mid-summer imagery.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 15 June 2014
4.3.2.1. Variances
There were no variances from the protocol described in the Study Plan for ITU classification or
ITU mapping.
5. RESULTS
The Results and Discussion sections are organized by the ecosystem components addressed in
this study in both the field and mapping work. The preliminary mapping prepared for FA-104
(Whiskers Slough), FA-115 (Slough 6A), and FA-128 (Slough 8A) is presented for review
because the mapping for the full study area will not be completed until the last year of study. In
both the Results and Discussions sections, the number and area covered by each of the ecosystem
component classes refers to the mapped classes occurring within the FA boundaries used in the
stratification process for plot allocation (light grey bounding boxes in Figures 4.2-4, and 5-1
through 5-5) and not the component classes occurring within the broader study area (Figure 4.3-
1). Tables 5-1 through 5-3 list the areal extent of each ecosystem component on the ITU map for
each FA, and the definitions of each of the component classes are provided in Tables 5-4 through
5-8.
To illustrate the ITU classification and mapping methods, and the map products to be prepared in
this study, the mapping presented in this report is limited to the three FAs noted above. In many
cases, ecosystem components were described in the field in the broader study area but were not
mapped in one of the three FAs (e.g., the vegetation class Subarctic Lowland Sedge-Moss Bog
Meadow); in those cases the additional component classes do not appear in the map figures and
area tables, but do occur in the description tables for each component. Similarly, ecosystem
component classes may appear in the map figures but were not included in the area tables
because they fell outside the FA boundaries for stratification. Tables 5-1 through 5-3 indicate
which of the ecosystem component classes were mapped within the FA boundaries used in the
stratification process for plot allocation. Hence, in the following section, the number of
ecosystem component classes may differ between the area tables, description tables, and/or map
legends for the reasons described above.
5.1. Ecosystem Components
The field ground-reference and ITU mapping data analyzed in this report are publicly available
on-line at http://gis.suhydro.org/reports/isr. The field data are in the file:
ISR_11_6_RIPR_Data_2012.accdb and the mapping data are in:
ISR_11_6_RIPR_Data_ABR.gdb.
5.1.1. Geomorphic Units
Eleven terrestrial geomorphic units were mapped within the three FAs (Figure 5-1, Tables 5-1
through 5-4). The most common geomorphic units in FA-104 (Whiskers Slough) were Meander
Inactive Overbank Deposit (18.3 percent of the mapped area), Meander Active Overbank
Deposit (15.1 percent), and Old Alluvial Terrace (11.4 percent) (Table 5-1). In FA-115 (Slough
6A), the most common types were Meander Active Overbank Deposit (20.4 percent), Meander
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 16 June 2014
Inactive Overbank Deposit (13.2 percent), and Meander Fine Active Channel Deposit (11.2
percent) (Table 5-2), and in FA-128 (Slough 8A) Meander Inactive Overbank Deposit (38.9
percent), Meander Active Overbank Deposit (14.5 percent), and Meander Fine Active Channel
Deposit (10.1 percent) were most common (Table 5-3).
Of the aquatic geomorphic units, Upper Perennial Glacial River (i.e., the Susitna River) was the
most common type in all three FAs, accounting for 20.3 percent, 33.5 percent, and 27.8 percent
of the mapped areas in FA-104 (Whiskers Slough), FA-115 (Slough 6A), and FA-128 (Slough
8A), respectively (Tables 5-1 through 5-3).
5.1.2. Surface Form
Ten surface form classes were mapped within the three FAs (Figure 5-2, Tables 5-1 through 5-3,
and 5-5). The most common surface form classes in all three FAs were Interfluv or Flat Bank,
accounting for 50.1 percent, 37.3 percent, and 53.4 percent of the mapped areas in FA-104
(Whiskers Slough), FA-115 (Slough 6A), and FA-128 (Slough 8A), respectively; and River or
Stream, which accounted for 21.0 percent, 33.5 percent, and 27.8 percent in of the mapped areas
in those same FAs, respectively (Tables 5-1 through 5-3). Terrace was the third most common
surface form in FA-104 (Whiskers Slough) (11.4 percent), while in FA-115 (Slough 6A) and FA-
128 (Slough 8A) the third most common surface form was Mid-Channel Bar (14.5 percent and
10.8 percent, respectively).
5.1.3. Vegetation
Twenty vegetation classes were mapped within the three FAs (Figure 5-3, Tables 5-1 through
5-3, and 5-6). The most common vegetation types in FA-104 (Whiskers Slough) were Open
Spruce-Paper Birch (47.4 percent of the mapped area), Fresh Water (22.2 percent), and Spruce-
Paper Birch Woodland (5.5 percent) (Table 5-1). The most common vegetation types in FA-115
(Slough 6A) were Fresh Water (34.8 percent), Closed Balsam Poplar Forest (10.0 percent), and
Ferns (7.9 percent) (Table 5-2).The most common vegetation types in FA-128 (Slough 8A) were
Open Balsam Poplar Forest (30.6 percent), Fresh Water (27.8 percent), and Closed Tall Willow
(14.3 percent) (Table 5-3).
5.1.4. Disturbance
Five disturbance classes were mapped within the three FAs (Figure 5-4, Tables 5-1 through 5-3,
and 5-7). The most common disturbance class in all three FAs was Absent (no disturbance
noted), which accounted for 44.8 percent, 53.6 percent, and 56.1 percent of the mapped areas in
FA-104 (Whiskers Slough), FA-115 (Slough 6A), and FA-128 (Slough 8A), respectively. The
next most common disturbance types were Wind (37.3 percent in FA-104 [Whiskers Slough]),
and Ice-Bulldozing (33.8 percent and 32.9 percent, respectively, in FA-115 [Slough 6A], and
FA-128 [Slough 8A]).
5.1.5. Poplar Size Class
Three balsam poplar size classes and one non-poplar class were mapped within the three FAs
(Figure 5-5, Tables 5-1 through 5-3, and 5-8). In FA-104 (Whiskers Slough), 94.5 percent of the
area was mapped as non-poplar vegetation types (Table 5-1); of the remaining area, 0.4 percent
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 17 June 2014
was Large Timber-sized poplar, 3.4 percent was Timber-sized poplar, and 1.6 percent was Pole-
sized poplar. In FA-115 (Slough 6A), 79.3 percent of the area was mapped as non-poplar
vegetation types (Table 5-2); of the remaining area, 6.5 percent was Large Timber-sized poplar,
11.3 percent was Timber sized poplar, and 2.9 percent was Pole sized poplar. In FA-128 (Slough
8A), 62.2 percent of the area was mapped as non-poplar vegetation types (Table 5-4); of the
remaining area 25.7 percent was Large Timber-sized poplar, 4.8 percent was Timber-sized
poplar, and 7.3 percent was Pole-sized poplar.
5.1.6. Ecotypes
Using the 2012 field data and map data from the three FAs, 29 preliminary ecotypes (25
terrestrial, 4 aquatic) were classified within the Middle River portion of the study area; this,
included 20 classified from the 2012 field data, and nine ecotypes that were mapped but not
sampled in the field in 2012 (Table 5.1-1). Twenty-three of the 29 preliminary ecotypes (19
terrestrial, 4 aquatic) were mapped within the three FAs (Figure 4.2-4, Tables 5-1 through 5-3,
and 5.1-2).
In FA-104 (Whiskers Slough), 12 terrestrial and 4 aquatic ecotypes were mapped (Table 5-1);
the most common terrestrial ecotypes were Riverine Loamy Spruce-Birch Forest (28.3 percent),
Upland Loamy Spruce-Birch Forest (24.6 percent), and Riverine Sandy Balsam Poplar Sapling-
Alder-Willow Tall Shrub (5.9 percent). In FA-115 (Slough 6A), 18 terrestrial and 2 aquatic
ecotypes were mapped (Table 5-2); the most common terrestrial ecotype were Riverine Sandy
Timber-sized Balsam Poplar Forest (11.3 percent), Riverine Loamy Spruce-Birch Forest (9.6
percent), and Riverine Sandy-Loamy Spruce-Balsam Poplar Forest (9.3 percent). In FA-128
(Slough 8A), 9 terrestrial and 1 aquatic ecotype were mapped (Table 5-3); the most common
terrestrial ecotypes were Riverine Sandy-Loamy Balsam Poplar Large Tree Forest (25.7
percent), Riverine Sandy Alder-Willow Tall Shrub (15.0 percent), and Riverine Sandy Pole-sized
Balsam Poplar Forest (7.3 percent). Of the aquatic ecotypes, Riverine Circumneutral Glacial
River was the most common in all three FAs, accounting for 20.3 percent, 33.5 percent, and 27.8
percent in FA-104 (Whiskers Slough), FA-115 (Slough 6A), and FA-128 (Slough 8A),
respectively.
6. DISCUSSION
The field data collection efforts and the mapping prepared in 2013 were conducted as planned
and described in the Study Plan. Substantial progress has been made in using the ITU field data
and mapping processes to characterize the local-scale riparian ecosystems occurring in the
Middle River portion of the study area; in the next study year, those efforts will be extended
upstream to the Project dam site and downstream into the Lower River portion of the study area.
The progress of the study to date is sufficient to meet the study objectives with an additional year
of field data collection, ITU mapping, and finally, the modeling of natural successional pathways
for riparian vegetation in the Susitna River floodplain downstream of the proposed Project dam
site.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 18 June 2014
6.1. Ecosystem Components
6.1.1. Geomorphic Units
Geomorphic units in riparian areas are ecologically important because they represent areas with
differing erosional and depositional characteristics and, as a result, they have different types of
naturally occurring topography, disturbance regimes, and vegetation. For instance, channel
deposits and overbank deposits were differentiated as separate geomorphic units because the
former have more frequent flooding and are characterized by intense scouring and deposition of
coarser sediments (sand and gravels), while the later are subject to lateral-flow overbank
flooding and are characterized by the deposition of finer sediments (fine sand, silt, and clay).
Channel deposits were further subdivided into two classes based on the dominate soil texture in
the upper 40 cm (16 in): coarse soils (loamy fine sand and coarser, and/or > 15% rock
fragments), and finer soils (finer than loamy fine sandy and < 15% rock fragments). Recognizing
that floodplain surfaces located at different elevations above the active river channel are
characterized by different flooding frequencies, three different types of overbank deposits
(active, inactive, and abandoned) were differentiated. Active overbank deposits are flooded
regularly (~1–15 years intervals) and may be flooded multiple times within a single year;
inactive overbank deposits are flooded irregularly (~15–75 year intervals); and abandoned
overbank deposits are rarely flooded (75–150 years). The disturbance regimes, soil textures, and
flood frequencies characteristic of these different floodplain surfaces result in differences in
vegetation. For instance, coarse active channel deposits are typically barren or partially
vegetated, while fine active channel deposits are characterized by willow-alder-poplar sapling
tall shrub. Active overbank deposits are characterized by balsam poplar and mixed balsam
poplar-white spruce stands, and inactive overbank deposits are characterized by white spruce-
paper birch forests.
6.1.2. Surface Form
Surface forms were characterized in this study because they are associated with local-scale
ecological gradients and processes, and disturbances, each of which influences localized
microtopography and vegetation establishment. For instance, tree mounds created by downed
logs and upturned root balls are local-scale microtopographic features with exposed mineral soil,
and these areas create microsites for seedling establishment.
In the ITU mapping process, researchers focused on those surface form classes that could be
readily identified on aerial imagery, and especially on their topographic position in the
floodplain. Topographic position determines the frequency and type of flooding, both of which
influence patterns of disturbance and vegetation establishment. For example, mid-channel bars
are frequently disturbed by ice flows during spring break-up, which can set back vegetation on
these bars to an earlier successional state. Mid-channel and lateral bars are also characterized by
abundant exposed sands and frequent flooding, a combination of factors which facilitates the
establishment of poplar and willow seedlings.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 19 June 2014
6.1.3. Vegetation
The type and distribution of vegetation in an area reflects a combination of the available species
pool, broad-scale climatic, and fine-scale topo-edaphic factors. For instance, the Riparian
Vegetation Study area is located in Southcentral Alaska on the floodplain of the Susitna River,
and in this area white spruce-paper birch forests, poplar forests, willow-alder scrub, fern and
large umbel meadows are common. At a local scale, the distribution of vegetation in a given
location is determined by fine-scale (1 to several m [3.3 to several ft]) topographic variability,
flood frequency, and patterns of disturbance. Vegetation is important ecologically in riparian
systems because it provides stability for fluvial soils, provides shade and cover for fish,
contributes large woody debris to the river channel, and provides nutrient rich litter into aquatic
systems. Riparian vegetation also provides food and cover for terrestrial wildlife, and serves as
the essential structure for wildlife habitats. For instance, willows are essential winter browse for
moose (Helm and Collins 1997), horsetails (Equisetum spp.) are an important spring food for
grizzly bears (Helm and Mayer 1985), and black bears utilize cavities in large cottonwoods for
winter den sites (Schwartz et al. 1987).
6.1.4. Disturbance
The focus in the ITU mapping was on recent (< 2–3 years) disturbances because recent
disturbances were more reliably identified on the aerial imagery than older disturbances, and
because the mapping is designed to represent contemporary floodplain conditions. Disturbance
plays a pivotal role in riparian areas where local-scale vegetation and soil patterns strongly
reflect patterns of disturbance. For instance, poplar sapling-alder-willow tall shrub is common in
areas that experience regular ice scour. On higher, older floodplain surfaces where flooding is
infrequent or rare, wind plays play a pivotal role in shaping forest structure. Large canopy gaps
are created by wind, resulting in the formation of birch-spruce woodlands on these surfaces.
6.1.5. Poplar size class
Poplar size class (Pole, Timber, and Large Timber) was mapped for contiguous balsam poplar
stands. The purpose of the poplar size classification was two-fold. First, it was designed to
facilitate the mapping of various successional stages of poplar that were observed on the Susitna
River floodplain. Second, it was designed to facilitate the mapping of wildlife habitat features,
including black bear denning and raptor nest trees. The poplar size classes were designed so that
the DBH range within each size class is ecologically important. For instance, the split between
the pole- and timber-size classes(30 cm [12 in]) was determined based on the susceptibility to
shearing by ice during spring break-up; trees smaller than this DBH are more prone to shearing
than trees larger than this size, which are big enough to deflect ice. The lower end of the large
timber size class (90 cm [35 in]) is the minimum diameter preferred by black bears for denning
trees (Schwartz et al. 1987). The large timber class also encompasses a range of diameters
typical of the dominant (often above-canopy) trees in a stand, which are commonly used as
nesting platforms by Bald Eagles (Ritchie and Ambrose 2008).
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 20 June 2014
6.1.6. Ecotypes
A hierarchical organization of physical and biological variables was used to classify the
preliminary ecotypes in this study. In this hierarchical methodology, the combination of
physiography (e.g., riverine, upland, lowland, which are strongly associated with geomorphic
units); soil texture; and vegetation structure yields ecotype classes that effectively differentiate
both soil characteristics and vegetation composition. This approach depends on characteristics
that are readily identifiable from aerial imagery, including physiography (e.g., floodplains versus
terraces); surface form (e.g., mid-channel bar vs. interfluv or flat bank); vegetation structure
(e.g., woodland vs. open forest); and successional stage (e.g., poplar size classes). Understanding
the associated variables is particularly important for differentiating ecotypes that (1) have
different disturbance regimes and may respond differently to changes in river hydrology related
to Project operational scenarios, and (2) are differentially important to wildlife for habitat. For
example, the ecotype Riverine Sandy Balsam Poplar Sapling-Alder-Willow Tall Shrub is prone
to disturbance by ice scour and shearing during spring break-up. Hence, this ecotype is likely to
be more sensitive to changes in the ice regime that may occur under certain Project operational
scenarios than Riverine Loamy Spruce-Birch Forest, which is more prone to wind disturbance
and rarely, if ever, is affected directly by ice scour and shearing. Another example relates to
wildlife habitat. The ecotype Riverine Sandy-Loamy Balsam Poplar Large Tree Forest is
characterized by large diameter poplars. As discussed above, large poplar trees are commonly
used by black bears as den sites, making this ecotype a favorable winter habitat for black bears.
The vegetation in this ecotype is characterized by a woodland (10–25% tree cover) forest and
features a thick cover of ferns (Matteuccia struthiopteris). Moose are unlikely to favor this
habitat because the poplar branches are too high to browse and the ferns are unpalatable. Moose
would, however, favor the ecotype Riverine Sandy Balsam Poplar Sapling-Alder-Willow Tall
Shrub due to the high cover of tall willows (Collins and Helm 1997).
Because the descriptions of the ecotypes classified in this report are preliminary and presently
are based on analysis of the 2012 field data only, nine ecotypes were mapped (in the Middle
River FAs) but were not described in the field. These ecotypes represent placeholders for the
purposes of the draft ecotype mapping and will be quantified and described during the next year
of study.
6.2. Interrelated Studies
The Riparian Vegetation Study is integrally related to four other studies being conducted in
riparian areas downstream of the proposed Project dam site. The set of five integrated riparian or
riverine studies includes the Riparian Vegetation Study, the Fluvial Geomorphology Modeling
below Watana Dam Study (Study 6.6), the Groundwater Study (Study 7.5), the Ice Processes in
the Susitna River Study (Study 7.6), and the Riparian IFS (Study 8.6). Each of these studies was
developed in detail, with extensive agency input, during the FERC Study Plan process in 2012
(see AEA 2012), and there was explicit recognition in the Study Plans for each study of the data
that would be needed to be supplied to each of the related studies. Each study also was designed
and scheduled so that those data would be available when needed. In 2013, the field work for the
Riparian Vegetation Study, the Groundwater Study (Study 7.5), and the Riparian IFS (Study 8.6)
were conducted in a collaborative fashion, with intensive data collected by all three studies in the
same three Middle River FAs discussed above. Overall, these studies are designed to provide
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 21 June 2014
data and/or modeling results to the study team for the Riparian IFS to support the modeling of
change in riparian areas that could result from construction and operation of the proposed
Watana Dam. The study teams for each of the four interrelated riparian/riverine studies
conducted extensive field work and data analysis in 2013, as was done in this study, and all
studies are on track to provide the necessary data and modeling results to the Riparian IFS (Study
8.6) study t eam to facilitate the modeling of change in riparian areas (see ISR Studies 6.6, 7.5,
7.6, and 8.6).
7. COMPLETING THE STUDY
[Section 7 appears in the Part C section of this ISR.]
8. LITERATURE CITED
ABR (ABR, Inc.—Environmental Research & Services). 2013. Riparian Vegetation Study
Downstream of the Proposed Susitna-Watana Dam. February 2013. Prepared for the
Alaska Energy Authority, Anchorage, AK, by ABR, Inc., Fairbanks, AK. 25 pp.
Available online at http://www.susitna-watanahydro.org/type/documents/. Accessed
October 2013.
Aalto, R., L. Maurice-Bourgoin, T. Dunne, D. R. Montgomery, C .A. Nittrouer and J. Guyot.
2003. Episodic sediment accumulation on Amazonian flood plains influenced by El
Nino/Southern Oscillation. Nature 425: 493–497.
Aalto, R., J. W. Lauer and W. E. Dietrich. 2008. Spatial and temporal dynamics of sediment
accumulation and exchange along Strickland River floodplains (Papua New Guinea) over
decadal-to-centennial timescales. Journal of Geophysical Research 113: 1–22.
Alaska Division of Geological and Geophysical Surveys (ADGGS). 1983. Engineering geology
mapping classification system. Alaska Division of Geology and Geophysical Surveys,
Fairbanks, AK.76 pp.
AEA (Alaska Energy Authority). 2012. Revised Study Plan, Susitna-Watana Hydroelectric
Project FERC Project No. 14241. December 2012. Prepared for the Federal Energy
Regulatory Commission by the Alaska Energy Authority, Anchorage, Alaska.
http://www.susitna-watanahydro.org/study-plan. Accessed October 2013.
R2/GW/ABR (R2 Resource Consultants, Inc., GW Scientific, and ABR, Inc.—Environmental
Research & Services). 2013. Riparian Instream Flow, Groundwater, and Riparian
Vegetation Studies FERC Determination Response Technical Memorandum. July 2013.
Prepared for the Alaska Energy Authority by R2 Resource Consultants, Inc., GW
Scientific, and ABR, Inc.—Environmental Research & Services, Anchorage and
Fairbanks, Alaska.
Collins, W. B., and D. J. Helm. 1997. Moose, Alces alces, habitat relative to riparian succession
in the boreal forest, Susitna River, Alaska. Canadian Field-Naturalist 111:567–574.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 22 June 2014
Gracz, M. 2011. Cook Inlet Lowland Wetlands. Available on-line at
http://cookinletwetlands.info/. Accessed September 2013
Helm, D., and P. V. Mayer. 1985. Susitna Hydroelectric Project environmental studies: plant
phenology study. Report prepared by University of Alaska–Fairbanks, Agricultural and
Forestry Experiment Station, Palmer, and Harza–Ebasco Susitna Joint Venture,
Anchorage, for Alaska Power Authority, Anchorage. 250 pp. [APA Doc. No. 2932]
Helm, D. J., and W. B. Collins. 1997. Vegetation succession and disturbance on a boreal forest
floodplain, Susitna River, Alaska. Canadian Field-Naturalist 111:553–566.
Jorgenson, M. T., J. E. Roth, S. F. Schlentner, E. R. Pullman, M. J, Macander, and C. H. Racine.
2003. An ecological land survey for Fort Richardson, Alaska. Technical Report
ERDC/CRREL TR-03-19.U.S. Army Corps of Engineers, Engineer Research and
Development Center, Cold Regions Research and Engineering Laboratory, Hanover,
New Hampshire.100 pp.
Jorgenson, M. J., J. E. Roth, P. F. Miller, M. J. Macander, M. S. Duffy, A. F. Wells, G. V. Frost,
and E. R. Pullman. 2009. An ecological land survey and landcover map of the Arctic
Network. Natural Resource Report NPS/ARCN/NRTR—2009/270. National Park
Service, Fort Collins, Colorado. 307 pp.
Kreig, R. A., and R. D. Reger. 1982. Air-photo analysis and summary of landform soil properties
along the route of the Trans-Alaska Pipeline System. Alaska Div. of Geological and
Geophysical Surveys, Geologic Report 66.149 pp.
McKendrick, J. D., W. Collins, D. Helm, J. McMullen, and J. Koranda. 1982. Susitna
Hydroelectric Project environmental studies, Phase I final report, Subtask 7.12—Plant
ecology studies. Prepared by University of Alaska, Agricultural Experiment Station,
Palmer, for Alaska Power Authority, Anchorage. 124 pp. + appendix. [APA Doc. No.
1321].
Miall, A. D. 1985. Architectural-element analysis: a new method of facies analysis applied to
fluvial deposits. Earth Sciences Review 22: 261–308.
Nossov, D. R., T. N. Hollingsworth, R. W. Ruess, and K. Keilland. 2011. Development of Alnus
tenuifolia stands on an Alaskan floodplain: patterns of recruitment, disease and
succession. Journal of Ecology 99: 621–633.
R2 (R2 Resource Consultants, Inc.). 2013. Technical Memoradum: Selection of Focus Areas and
Study Sites in the Middle and Lower Susitna River for Instream Flow and Joint Research
Studies, FERC Project No. 14241. March 2013. Prepared for the Alaska Energy
Authority by R2 Resource Consultants, Inc., Anchorage, Alaska.
Ritchie, R. J., and R. E. Ambrose. 2008. Distribution, Abundance, and Status of Bald Eagles in
Interior Alaska. In Bald Eagles in Alaska, Bruce A. Wright and Phil Schempf, eds.
University of Alaska Southeast, Juneau, AK.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 23 June 2014
Ruess, R. W., J. M. McFarland, L. M. Trummer, and J. K. Rohrs-Richey. 2009. Disease-
Mediated Declines in N-Fixation Inputs by Alnus tenuifolia to Early-Successional
Floodplains in Interior and South-Central Alaska. Ecosystems 12: 489–502.
Schoeneberger, P. J., D. A. Wysocki, E. C. Benham, and Soil Survey Staff.2012.Field book for
describing and sampling soils, Version 3.0, Natural Resources Conservation Service,
National Soil Survey Center, Lincoln, NE.
Schwartz, C. C., S. D. Miller, and A. W. Franzmann. 1987. Denning ecology of three black bear
populations in Alaska. International Conference on Bear Research and Management
7:281–291.
UAFAFES (University of Alaska Fairbanks Agricultural and Forestry Experiment Station).
1985. Susitna Hydroelectric Project, riparian vegetation succession report. Prepared by
University of Alaska–Fairbanks Agricultural and Forestry Experiment Station, Palmer,
for Harza–Ebasco Susitna Joint Venture and Alaska Power Authority, Anchorage. 169
pp. [APA Doc. No. 3099].
U.S. Department of Agriculture, Natural Resources Conservation Service (USDA NRCS). 2004.
Soil Survey Laboratory Methods Manual, Version 4.0. R. Burt, Ed. Soil Survey
Investigations Report No. 42.National Soil Survey Center, Natural Resource
Conservation Service, U.S. Dept. of Agriculture, Lincoln, NE. Available on-line at
http://soils.usda.gov/technical/lmm/. Accessed October 2013.
USGS (U.S. Geological Survey). 1999. National Hydrography Dataset—Medium resolution.
Prepared by the U.S. Geological Survey in cooperation with the U.S. Environmental
Protection Agency. Reston, Virginia. Available on-line at http://nhd.usgs.gov. Accessed
October 2012.
Viereck, L. A., C. T. Dyrness, A. R. Batten, and K. J. Wenzlick. 1992. The Alaska Vegetation
Classification. Gen. Tech. Rep. PNW-GTR-286.Pacific Northwest Research Station, U.S.
Forest Service, Portland, Oregon.278 pp.
Washburn, A. L. 1973. Periglacial processes and environments. Edward Arnold, London. 320 pp.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 24 June 2014
9. TABLES
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 25 June 2014
Table 4.2-1. ELS Plots Allocated Randomly by Ecotype in Focus Area 104 (Whiskers Slough), Middle Susitna River, Riparian Vegetation Study Area, Susitna-Watana
Hydroelectric Project, 2013.1
Terrestrial Ecotypes2 Area (acres) % of Total Terrestrial Area
Proportion of Total Samples (N*% area) 3 No. Plots Allocated
No. Sampled in 2013
Lowland Organic-rich Bluejoint-Herb Meadow 1.1 0.2% 0.1 0 0
Riverine Gravelly Wormwood-Horsetail Barrens and Partially
Vegetated 7.8 1.6% 0.7 2 2
Riverine Loamy Ostrich Fern Meadow 23.8 4.8% 2.0 4 2
Riverine Loamy Spruce-Birch Forest 182.0 36.4% 15.7 7 5
Riverine Sandy Balsam Poplar Sapling-Alder-Willow Tall Shrub 37.7 7.5% 3.2 4 3
Riverine Sandy Bluejoint-Herb Meadow 15.5 3.1% 1.3 2 1
Riverine Sandy Pole-sized Balsam Poplar Forest 10.5 2.1% 0.9 4 3
Riverine Sandy Timber-sized Balsam Poplar Forest 22.1 4.4% 1.9 4 5
Riverine Sandy-Loamy Balsam Poplar Large Tree Forest 2.5 0.5% 0.2 0 0
Riverine Sandy-Loamy Spruce-Balsam Poplar Forest 33.7 6.7% 2.9 5 4
Riverine Wet Sedge-Forb Marsh 5.0 1.0% 0.4 0 0
Upland Loamy Spruce-Birch Forest 158.1 31.6% 13.6 6 3
FA-104 (Whisker Slough) Totals 499.8 100.0% 43.0 38 28
Notes:
1 Plots allocated by stratified random allocation procedures with ecotype as the stratum (see text).
2 Total number of ecotypes (ET) = 12.
3 Approximate total number of plots in FA-104 (Whiskers Slough) (N) (1 plot/20 acres + 1.5*ET) = 43.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 26 June 2014
Table 4.2-2. ELS Plots Allocated Randomly by Ecotype in Focus Area 115 (Slough 6A), Middle Susitna River, Riparian Vegetation Study Area, Susitna-Watana
Hydroelectric Project, 2013.1
Terrestrial Ecotypes2
Area
(acres)
% of Total
Terrestrial Area
Proportion of Total Samples
(N*% area)3
No. Plots
Allocated
No. Sampled in
2013
Lowland Loamy Birch Forest 6.7 2.1% 0.9 2 0
Lowland Loamy Ostrich Fern Meadow 1.3 0.4% 0.2 0 0
Lowland Organic-rich Bluejoint-Herb Meadow 11.3 3.5% 1.5 2 1
Riverine Complex 5.1 1.6% 0.7 0 0
Riverine Gravelly Wormwood-Horsetail Barrens and Partially
Vegetated 17.6 5.5% 2.4 2 1
Riverine Loamy Birch Forest 8.8 2.7% 1.2 2 0
Riverine Loamy Ostrich Fern Meadow 37.5 11.6% 5.0 2 1
Riverine Loamy Spruce-Birch Forest 47.7 14.8% 6.4 5 3
Riverine Sandy Alder-Willow Tall Shrub 4.4 1.4% 0.6 0 0
Riverine Sandy Balsam Poplar Sapling-Alder-Willow
Tall Shrub 7.2 2.2% 1.0 2 1
Riverine Sandy Bluejoint-Herb Meadow 13.4 4.1% 1.8 5 3
Riverine Sandy Pole-sized Balsam Poplar Forest 14.1 4.4% 1.9 4 2
Riverine Sandy Timber-sized Balsam Poplar Forest 55.9 17.3% 7.4 4 3
Riverine Sandy-Loamy Balsam Poplar Large Tree Forest 32.3 10.0% 4.3 4 3
Riverine Sandy-Loamy Spruce-Balsam Poplar Forest 46.1 14.3% 6.1 5 2
Riverine Wet Sedge-Forb Marsh 6.2 1.9% 0.8 1 1
Upland Loamy Spruce-Birch Forest 6.6 2.1% 0.9 2 2
Upland, undifferentiated 0.2 0.1% 0.0 0 0
FA-115 (Slough 6A) Totals 322.5 100.0% 43.0 42 23
Notes:
1 Plots allocated by stratified random allocation procedures with ecotype as the stratum (see text).
2 Total number of ecotypes (ET) = 18.
3 Approximate total number of plots in FA-115 (Slough 6A) (N) (1 plot/ 20 acres + 1.5* ET) = 43.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 27 June 2014
Table 4.2-3. ELS Plots Allocated Randomly by Ecotype in Focus Area 128 (Slough 8A), Middle Susitna River, Riparian Vegetation Study Area, Susitna-Watana
Hydroelectric Project, 2013.1
Terrestrial Ecotypes2 Area (acres) No. Water Bodies % of Total Terrestrial Area
Proportion of Total Samples (N*% area) 3 No. Plots Allocated
No. Sampled in 2013
Human Modified 0.5 0.1% 0.0 0 0
Riverine Gravelly Wormwood-Horsetail Barrens and
Partially Vegetated 39.4 8.8% 3.2 5 0
Riverine Loamy Spruce-Birch Forest 7.7 1.7% 0.6 0 0
Riverine Sandy Alder-Willow Tall Shrub 92.9 20.7% 7.5 7 1
Riverine Sandy Balsam Poplar Sapling-Alder-Willow
Tall Shrub 39.9 8.9% 3.2 5 0
Riverine Sandy Pole-sized Balsam Poplar Forest 45.2 10.1% 3.6 5 0
Riverine Sandy Timber-sized Balsam Poplar Forest 30.1 6.7% 2.4 4 0
Riverine Sandy-Loamy Balsam Poplar Large Tree
Forest 159.6 35.6% 12.8 8 2
Riverine Sandy-Loamy Spruce-Balsam Poplar Forest 33.4 7.4% 2.7 4 1
FA-128 (Slough 8A) Totals 448.5 100.0% 36.0 38 4
Notes:
1 Plots allocated by stratified random allocation procedures with ecotype as the stratum (see text).
2 Total number of ecotypes (ET) = 9.
3 Approximate total number of plots in FA-128 (Slough 8A) (N) (1 plot/ 20 acres + 1.5* ET) = 36.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 28 June 2014
Table 4.2-4. ELS Plots Allocated By Ecotype in Focus Areas (FAs) and Satellite Areas (SAs), Middle Susitna River, Riparian Vegetation Study Area, Susitna-Watana
Hydroelectric Project, 2013.
Terrestrial Ecotypes
Area
(Acres)1
% of Terrestrial
Ecotypes
No. Allocated Plots
in FAs2
No. Allocated Plots
in Satellite Areas
Total Allocated Plots in Middle
River
No. Sampled in
2013 in FAs [SAs]
Human Modified 43.2 0.7% 0 0 0 0
Lowland Loamy Birch Forest 125.2 2.0% 2 0 2 0
Lowland Loamy Ostrich Fern Meadow 1.3 0.0% 0 0 0 0
Lowland Organic-rich Bluejoint-Herb
Meadow 12.4 0.2% 2 0 2 1 [1]
Lowland Organic-rich Sedge Meadow 2.7 0.0% 0 0 0 0
Lowland Organic-Rich Wet Spruce
Forest 6.4 0.1% 0 0 0 0
Riverine Complex 42.9 0.7% 0 0 0 0
Riverine Gravelly Wormwood-
Horsetail Barrens and Partially
Vegetated 722.7 11.5% 9 2 11 3 [1]
Riverine Loamy Birch Forest 45.2 0.7% 2 0 2 0
Riverine Loamy Large Umbel Meadow 29.8 0.5% 0 6 6 [1]
Riverine Loamy Ostrich Fern Meadow 127.8 2.0% 6 6 12 3
Riverine Loamy Spruce-Birch Forest 1068.0 17.0% 12 0 12 8
Riverine Sandy Alder-Willow Tall
Shrub 421.8 6.7% 7 1 8 1
Riverine Sandy Balsam Poplar
Sapling-Alder-Willow Tall Shrub 475.4 7.6% 11 2 13 4 [1]
Riverine Sandy Bluejoint-Herb
Meadow 39.4 0.6% 7 4 11 4
Riverine Sandy Pole-sized Balsam
Poplar Forest 332.5 5.3% 13 2 15 5
Riverine Sandy Spruce Forest 181.8 2.9% 0 4 4 0
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 29 June 2014
Terrestrial Ecotypes Area (Acres)1 % of Terrestrial Ecotypes
No. Allocated Plots in FAs2
No. Allocated Plots in Satellite Areas
Total Allocated Plots in Middle River No. Sampled in 2013 in FAs [SAs]
Riverine Sandy Timber-sized Balsam
Poplar Forest 652.4 10.4% 12 1 13 8
Riverine Sandy-Loamy Balsam Poplar
Large Tree Forest 571.7 9.1% 12 2 14 5
Riverine Sandy-Loamy Spruce-
Balsam Poplar Forest 667.9 10.6% 14 2 16 7
Riverine Wet Sedge-Forb Marsh 39.7 0.6% 1 5 6 1 [1]
Upland Barrens 1.9 0.0% 0 0 0 0
Upland Birch Forest 1.4 0.0% 0 0 0 0
Upland Loamy Spruce-Birch Forest 551.5 8.8% 8 0 8 5
Upland Poplar 32.4 0.5% 0 0 0 0
Upland Willow 4.6 0.1% 0 0 0 0
Upland, undifferentiated 88.1 1.4% 0 0 0 0
Total Terrestrial Ecotypes 6290.2 100.0% 118 37 155 60
Aquatic Ecotypes Area (Acres) % of Aquatic Ecotypes
Lowland Headwater Stream 6.6 0.2% 0 0 0 0
Riverine Circumneutral Beaver Pond 37.5 1.2% 0 0 0 0
Riverine Circumneutral Glacial River 3143.2 98.5% 0 0 0 0
Riverine Slough 5.3 0.2% 0 0 0 0
Total Aquatic Ecotypes 3192.6 100.0% 0 0 0 0
Grand Total 9482.8
Notes:
1 Areal Extent of ITU mapping completed to date includes : PRM 104.8-106.5 (FA-104 [Whiskers Slough]), 115.3-117.4 (FA-115 [Slough 6A]), 121.0-147.1
(includes FA-128 [Slough 8A and FA-138 [Gold Creek]), 173.0-175.4 (FA-173 [Stephan Lake Complex]).
2 Plots allocated by stratified random allocation procedures with ecotype as the stratum (see text).
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 30 June 2014
Table 4.3-1. Coding System for Classifying and Mapping Geomorphic Units, Surface Forms, Vegetation, Disturbance,
and Poplar Size Classes, Riparian Vegetation Study, Susitna-Watana Hydroelectric Project, 2013.
Code Class FA Map
Class
GEOMORPHIC UNIT
Terrestrial
Fboa Braided Active Overbank Deposit
Fbob Braided Abandoned Overbank
Deposit
Fboi Braided Inactive Overbank Deposit
Fbra Braided Active Channel Deposit
Fbrac Braided Coarse Active Channel
Deposit
Fbraf Braided Fine Active Channel Deposit
Fbri Braided Inactive Channel Deposit
Fbrif Braided Fine Inactive Channel
Deposit
Fmoa Meander Active Overbank Deposit X
Fmob Meander Abandoned Overbank
Deposit
X
Fmoi Meander Inactive Overbank Deposit X
Fmra Meander Active Channel Deposit
Fmrac Meander Coarse Active Channel
Deposit
X
Fmraf Meander Fine Active Channel Deposit X
Fmrb Meander Abandoned Channel Deposit X
Fmrbf Meander Fine Abandoned Channel
Deposit
Fmri Meander Inactive Channel Deposit
Fmrif Meander Fine Inactive Channel
Deposit
X
Fto Old Alluvial Terrace X
Ftr Recent Alluvial Terrace
Hfg Gravel Fill X
Ob Bogs
Of Organic Fen
Ofc Channel Fen X
U Upland, undifferentiated X
Code Class
FA Map
Class
Aquatic
Wrhl Lowland Headwater Stream X
Wrug Upper Perennial River, glacial X
Wrsl Riverine Slough X
Wlscv Shallow Connected Beaver Pond X
SURFACE FORM
B Basins Or Depressions
Dc Riverbed Cobbles or Boulders
Dr Ripples
Ds Scour channels-ridges
Fbl Lateral Bar X
Fbm Mid-Channel Bar X
Fbp Point Bar
Fc Channel, Swale Or Gut X
Ff Flood Basin X
Fi Interfluv Or Flat Bank X
Ft Terrace X
Hm Human modified X
Mid Ice-rafted debris
Mir Ice-shoved ridge
Ml Tree mounds
Mpm Peat mounds
Mu Undifferentiated mounds
N Nonpatterned
R River Or Stream X
U Upland, undifferentiated X
W Waterbodies X
Code Class
FA Map
Class
SURFACE FORM
Xcb Braided Channels And Interfluvs
VEGETATION CLASS
Bbg Barren
Bpv Partially Vegetated X
Dc Disturbance complex
Fbcb Closed Paper Birch Forest
Fbcp Closed Balsam Poplar Forest X
Fbob Open Paper Birch Forest X
Fbop Open Balsam Poplar Forest X
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 31 June 2014
Fbwb Paper Birch Woodland X
Fbwp Balsam Poplar Woodland X
Fmcpws Closed Balsam Poplar-White
Spruce Forest
Fmobps Open Paper Birch-Balsam Poplar-
Spruce Forest
Fmosb Open Spruce-Paper Birch Forest X
Fmosp Open Spruce-Balsam Poplar Forest X
Fmwsb Spruce-Paper Birch Woodland X
Fmwsp Spruce-Balsam Poplar Woodland X
Fnobs Open Black Spruce Forest
Fnows Open White Spruce Forest
Fnwbs Black Spruce Woodland
Hfmc Ferns X
Hfmu Large Umbel
Hfw Wet Forb Meadow X
Hfwfh Fresh Herb Marsh
Hfwhb Subarctic Lowland Herb Bog
Meadow
Hgmb Bluejoint Meadow X
Hgmbh Bluejoint-Herb
Code Class
FA
Map Class
Hgmbs Bluejoint-Shrub
Hgwfs Fresh Sedge Marsh
Hgwg Subarctic Lowland Grass Wet
Meadow
Hgwgh Subarctic Lowland Graminoid-Herb
Wet Meadow
Hgwsb Subarctic Lowland Sedge Bog
Meadow
Hgwsl Subarctic Lowland Sedge Wet
Meadow
Hgwsmb Subarctic Lowland Sedge-Moss
Bog Meadow
Sddt Dryas Dwarf Shrub Tundra
Sfcpa Closed Poplar Woodland-Alder Tall
Shrub
X
Sfcpw Closed Poplar Woodland-Willow
Tall Shrub
Sfopa Open Poplar Woodland-Alder Tall
Shrub
Sfopaw Open Poplar Woodland-Alder-
Willow Tall Shrub
X
Sfopw Open Poplar Woodland-Willow Tall
Shrub
Sfwbs Dwarf Black Spruce Woodland
Slcr Closed Low Rose Shrub
Sloaw Open Low Alder-Willow Shrub
Slobb Open Low Shrub Birch-Ericaceous
Shrub Bog
Sloeb Open Low Ericaceous Shrub Bog
Slor Open Low Rose Shrub
Slow Open Low Willow Shrub X
Stca Closed Tall Alder Shrub
Stcaw Closed Tall Alder-Willow Shrub
Stcw Closed Tall Willow Shrub X
Stoa Open Tall Alder Shrub
Stoaw Open Tall Alder-Willow Shrub
Stow Open Tall Willow Shrub
U Upland, undifferentiated X
Code Class
FA
Map Class
VEGETATION CLASS
Wf Fresh Water X
Xr Riverine Complex X
DISTURBANCE CLASS
A Absent, None (mature vegetation) X
Ngf Fluvial
Ngfd Fluvial Deposition
Ngfe Fluvial Erosion/channel migration
Hc Undifferentiated Clearing
Hfg Gravel Fill X
Hdr Residential Development
Ng Geomorphic Process X
Ngi Ice Bulldozing X
Nwd Wind X
POPLAR SIZE CLASS
P Pole (5–30 cm DBH) X
T Timber (31–90 cm DBH) X
L Large Timber (> 90 cm DBH) X
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 32 June 2014
Table 5-1. Areal Extent of Individual Integrated Terrain Unit Classes and Aggregated Ecotype Classes in Focus Area 104
(Whiskers Slough), Middle Susitna River, Riparian Vegetation Study Area, Susitna-Watana Hydroelectric Project, 2013.1
Acres %
GEOMORPHIC UNIT
Terrestrial
Meander Inactive Overbank Deposit 117.5 18.3
Meander Active Overbank Deposit 97.2 15.1
Old Alluvial Terrace 73.4 11.4
Meander Fine Active Channel Deposit 56.3 8.8
Meander Fine Inactive Channel Deposit 55.9 8.7
Meander Abandoned Channel Deposit 43.5 6.8
Meander Abandoned Overbank Deposit 42.3 6.6
Meander Coarse Active Channel Deposit 8.6 1.3
Channel Fen 5.0 0.8
Aquatic
Lowland Headwater Stream 5.0 0.8
Riverine Slough 2.9 0.5
Shallow Connected Beaver Pond 4.3 0.7
Upper Perennial Glacial River 130.6 20.3
TOTAL 642.7 100.0
AGGREGATED SUBTOTALS
Terrestrial Geomorphic Units 499.8 77.8
Fresh Water 142.8 22.2
SURFACE FORM
Interfluv or Flat Bank 322.0 50.1
River or Stream 134.7 21.0
Terrace 73.4 11.4
Mid-Channel Bar 52.8 8.2
Channel, Swale Or Gut 48.4 7.5
Lateral Bar 7.1 1.1
Water Bodies 4.3 0.7
TOTAL 642.7 100.0
Acres %
VEGETATION CLASS
Open Spruce-Paper Birch Forest 304.8 47.4
Fresh Water 142.8 22.2
Spruce-Paper Birch Woodland 35.3 5.5
Ferns 23.8 3.7
Open Poplar Woodland-Alder-Willow Tall
Shrub
21.7 3.4
Spruce–Balsam Poplar Woodland 21.0 3.3
Closed Balsam Poplar Forest 17.6 2.7
Bluejoint Meadow 16.6 2.6
Closed Poplar Woodland–Alder Tall
Shrub
16.0 2.5
Open Spruce–Balsam Poplar Forest 12.7 2.0
Open Balsam Poplar Forest 10.6 1.6
Partially Vegetated 7.8 1.2
Balsam Poplar Woodland 6.9 1.1
Wet Forb Meadow 5.0 0.8
TOTAL 642.7 100.0
DISTURBANCE CLASS
Absent, None 287.9 44.8
Ice Bulldozing 114.8 17.9
Wind 240.0 37.3
TOTAL 642.7 100.0
POPLAR SIZE CLASS
Poplar vegetation types
Large Timber (> 90 cm DBH) 2.5 0.4
Pole (5–30 cm DBH) 10.5 1.6
Timber (31–90 cm DBH) 22.1 3.4
Non Poplar Vegetation Types 607.6 94.5
TOTAL 642.7 100.0
Acres %
ECOTYPE
Terrestrial
Lowland Organic-rich Bluejoint-Herb
Meadow
1.1 0.2
Riverine Gravelly Wormwood-Horsetail
Barrens and Partially Vegetated
7.8 1.2
Riverine Loamy Ostrich Fern Meadow 23.8 3.7
Riverine Loamy Spruce-Birch Forest 182.0 28.3
Riverine Sandy Balsam Poplar Sapling-
Alder-Willow Tall Shrub
37.7 5.9
Riverine Sandy Bluejoint-Herb Meadow 15.5 2.4
Riverine Sandy Pole-sized Balsam
Poplar Forest
10.5 1.6
Riverine Sandy Timber-sized Balsam
Poplar Forest
22.1 3.4
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 33 June 2014
Riverine Sandy-Loamy Balsam Poplar
Large Tree Forest
2.5 0.4
Riverine Sandy-Loamy Spruce-Balsam
Poplar Forest
33.7 5.2
Riverine Wet Sedge-Forb Marsh 5.0 0.8
Upland Loamy Spruce-Birch Forest 158.1 24.6
Aquatic
Lowland Headwater Stream 5.0 0.8
Riverine Circumneutral Beaver Pond 4.3 0.7
Riverine Circumneutral Glacial River 130.6 20.3
Riverine Slough 2.9 0.5
TOTAL 642.7 100.0
AGGREGATED SUBTOTALS
Terrestrial Ecotypes 499.8 77.8
Aquatic Ecotypes 142.8 22.2
Note:
1 Area figures for each class represent the area
mapped within the FA boundaries used for
stratification in plot allocation (see text).
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 34 June 2014
Table 5-2. Areal Extent of Individual Integrated Terrain Unit Classes and Aggregated Ecotype Classes in Focus Area 115
(Slough 6A), Middle Susitna River, Riparian Vegetation Study Area, Susitna-Watana Hydroelectric Project, 2013.1
Acres %
GEOMORPHIC UNIT
Terrestrial
Meander Active Overbank Deposit 100.9 20.4
Meander Inactive Overbank Deposit 65.4 13.2
Meander Fine Active Channel Deposit 55.3 11.2
Meander Fine Inactive Channel Deposit 48.1 9.7
Meander Abandoned Overbank Deposit 26.8 5.4
Meander Coarse Active Channel Deposit 22.2 4.5
Channel Fen 3.5 0.7
Upland, undifferentiated 0.2 0.0
Aquatic
Shallow Connected Beaver Pond 6.6 1.3
Upper Perennial Glacial River 165.8 33.5
TOTAL 494.9 100.0
AGGREGATED SUBTOTALS
Terrestrial Geomorphic Units 322.5 65.2
Fresh Water 172.4 34.8
SURFACE FORM
Channel, Swale Or Gut 51.6 10.4
Flood Basin 8.4 1.7
Interfluv Or Flat Bank 184.8 37.3
Lateral Bar 6.0 1.2
Mid-Channel Bar 71.6 14.5
River Or Stream 165.8 33.5
Water bodies 6.6 1.3
Upland, undifferentiated 0.2 0.0
TOTAL 494.9 100.0
Acres %
VEGETATION CLASS
Balsam Poplar Woodland 14.3 2.9
Bluejoint Meadow 24.7 5.0
Closed Balsam Poplar Forest 49.3 10.0
Closed Tall Willow Shrub 4.4 0.9
Ferns 38.9 7.9
Fresh Water 172.4 34.8
Open Balsam Poplar Forest 38.7 7.8
Open Paper Birch Forest 6.7 1.4
Open Poplar Woodland-Alder-Willow Tall
Shrub
7.2 1.5
Open Spruce-Paper Birch Forest 26.4 5.3
Open Spruce-Paper Birch Forest 26.4 5.3
Open Spruce–Balsam Poplar Forest 18.1 3.7
Paper Birch Woodland 8.8 1.8
Partially Vegetated 17.6 3.6
Riverine Complex 5.1 1.0
Spruce-Balsam Poplar Woodland 28.0 5.7
Spruce-Paper Birch Woodland 27.9 5.6
Wet Forb Meadow 6.2 1.2
Upland, undifferentiated 0.2 0.0
TOTAL 494.9 100.0
DISTURBANCE CLASS
Absent, None 265.4 53.6
Ice Bulldozing 167.5 33.8
Wind 62.0 12.5
TOTAL 494.9 100.0
Acres %
POPLAR SIZE CLASS
Poplar vegetation types
Large Timber (> 90 cm DBH) 32.3 6.5
Pole (5–30 cm DBH) 14.1 2.9
Timber (31–90 cm DBH) 55.9 11.3
Non Poplar Vegetation Types 392.6 79.3
TOTAL 494.9 100.0
ECOTYPE
Terrestrial
Lowland Loamy Birch Forest 6.7 1.4
Lowland Loamy Ostrich Fern Meadow 1.3 0.3
Lowland Organic-rich Bluejoint-Herb
Meadow
11.3 2.3
Riverine Complex 5.1 1.0
Riverine Gravelly Wormwood-Horsetail
Barrens and Partially Vegetated
17.6 3.6
Riverine Loamy Birch Forest 8.8 1.8
Riverine Loamy Ostrich Fern Meadow 37.5 7.6
Riverine Loamy Spruce-Birch Forest 47.7 9.6
Riverine Sandy Alder-Willow Tall Shrub 4.4 0.9
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 35 June 2014
Riverine Sandy Balsam Poplar Sapling-
Alder-Willow Tall Shrub
7.2 1.5
Riverine Sandy Bluejoint-Herb Meadow 13.4 2.7
Riverine Sandy Pole-sized Balsam
Poplar Forest
14.1 2.9
Riverine Sandy-Loamy Balsam Poplar
Large Tree Forest
32.3 6.5
Riverine Sandy-Loamy Spruce-Balsam
Poplar Forest
46.1 9.3
Riverine Wet Sedge-Forb Marsh 6.2 1.2
Upland Loamy Spruce-Birch Forest 6.6 1.3
Upland, undifferentiated 0.2 0.0
Acres %
ECOTYPE
Aquatic
Riverine Circumneutral Beaver Pond 6.6 1.3
Riverine Circumneutral Glacial River 165.8 33.5
TOTAL 494.9 100.0
AGGREGATED SUBTOTALS
Terrestrial Ecotypes 322.5 65.2
Aquatic Ecotypes 172.4 34.8
Note:
1 Area figures for each class represent the area
mapped within the FA boundaries used for
stratification in plot allocation (see text).
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 36 June 2014
Table 5-3. Areal Extent of Individual Integrated Terrain Unit Classes and Aggregated Ecotype Classes in Focus Area 128
(Slough 8A), Middle Susitna River, Riparian Vegetation Study Area, Susitna-Watana Hydroelectric Project, 2013.1
Acres %
GEOMORPHIC UNIT
Terrestrial
Gravel Fill 0.5 0.1
Meander Active Overbank Deposit 89.8 14.5
Meander Coarse Active Channel
Deposit
39.4 6.3
Meander Fine Active Channel Deposit 62.9 10.1
Meander Fine Inactive Channel
Deposit
14.4 2.3
Meander Inactive Overbank Deposit 241.5 38.9
Aquatic
Upper Perennial Glacial River 172.5 27.8
TOTAL 621.0 100.0
AGGREGATED SUBTOTALS
Terrestrial Geomorphic Units 448.5 72.2
Fresh Water 172.5 27.8
SURFACE FORM
Channel, Swale Or Gut 8.2 1.3
Human Modified 0.5 0.1
Interfluv Or Flat Bank 331.3 53.4
Lateral Bar 41.6 6.7
Mid-Channel Bar 66.9 10.8
River Or Stream 172.5 27.8
TOTAL 621.0 100.0
VEGETATION CLASSES
Balsam Poplar Woodland 17.2 2.8
Closed Balsam Poplar Forest 27.8 4.5
Closed Poplar Woodland-Alder Tall
Shrub
11.7 1.9
Closed Tall Willow Shrub 88.9 14.3
Fresh Water 172.5 27.8
Acres %
VEGETATION CLASS
Open Balsam Poplar Forest 189.8 30.6
Open Low Willow Shrub 4.0 0.6
Open Poplar Woodland-Alder-Willow
Tall Shrub
28.2 4.5
Open Spruce-Balsam Poplar Forest 10.3 1.7
Partially Vegetated 39.9 6.4
Spruce-Balsam Poplar Woodland 23.1 3.7
Spruce-Paper Birch Woodland 7.7 1.2
TOTAL 621.0 100.0
DISTURBANCE CLASS
Absent, None 348.3 56.1
Geomorphic Process 3.9 0.6
Gravel Fill 0.5 0.1
Ice Bulldozing 204.3 32.9
Wind 64.0 10.3
TOTAL 621.0 100.0
POPLAR SIZE CLASS
Poplar vegetation types
Large Timber (> 90 cm DBH) 159.6 25.7
Pole (5–30 cm DBH) 45.2 7.3
Timber (31–90 cm DBH) 30.1 4.8
Non Poplar Vegetation Types 386.2 62.2
TOTAL 621.0 100.0
ECOTYPE
Terrestrial
Human Modified 0.5 0.1
Riverine Gravelly Wormwood-
Horsetail Barrens and Partially
Vegetated
39.4 6.3
Acres %
ECOTYPE
Terrestrial
Riverine Loamy Spruce-Birch Forest 7.7 1.2
Riverine Sandy Alder-Willow Tall
Shrub
92.9 15.0
Riverine Sandy Balsam Poplar
Sapling-Alder-Willow Tall Shrub
39.9 6.4
Riverine Sandy Pole-sized Balsam
Poplar Forest
45.2 7.3
Riverine Sandy Timber-sized Balsam
Poplar Forest
30.1 4.8
Riverine Sandy-Loamy Balsam Poplar
Large Tree Forest
159.6 25.7
Riverine Sandy-Loamy Spruce-
Balsam Poplar Forest
33.4 5.4
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 37 June 2014
Aquatic
Riverine Circumneutral Glacial River 172.5 27.8
TOTAL 621.0 100.0
AGGREGATED SUBTOTALS
Terrestrial Ecotypes 448.5 72.2
Aquatic Ecotypes 172.5 27.8
Note:
1 Area figures for each class represent the area mapped
within the FA boundaries used for stratification in plot
allocation (see text).
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 38 June 2014
Table 5-4. Classification and Description of Geomorphic Units and Water Bodies in the Middle Susitna River Portion of
the Riparian Vegetation Study Area, Susitna-Watana Hydroelectric Project, 2013.
Geomorphic Unit Description
TERRESTRIAL
Alluvial Fan (Ff) Gently sloping cone-shaped deposit of alluvium formed where a stream extends onto a relatively
level plain, such as where streams issue from mountains onto lowland. Alluvial fans are comprised
predominantly of coarse-grained materials, but also have varying quantities of silt.
Bogs (Ob) Ombrotrophic wetlands with thick (> 40 cm [16 in]) organic matter accumulations developed in
basins with essentially closed drainage receiving their water from precipitation and immediate
surroundings. Water chemistry is typically acidic (pH ≤ 5.5) and dissolved minerals are present at
low concentration (electrical conductivity < 100 µS). The surface is flat and the water table is near
the surface. Organic matter is dominated by fibric peat of Sphagnum mosses and ericaceous woody
material, but may be underlain by sedge peat.
Braided Abandoned
Overbank Deposit
(Fbob)
Vertical accretion deposits of braided floodplains that no longer are associated with the present
fluvial regime or where flooding is sufficiently infrequent that fluvial sediments form a negligible
component of surface material. Surface materials often include a mixture of fluvial, eolian, and
organic materials, but typically are highly organic. The deposits are > 40 cm (16 in) thick, and
organic layers comprise > 40% of the top 40 cm (16 in).
Braided Active Channel
Deposit (Fbra)
Lateral accretion deposits formed in braided channels that interweave as a result of repeated
bifurcations and convergences of flow around inter-channel bars.1 Riverbed material can range from
gravels and cobbles to gravelly-cobbly sand. Surface organic materials are typically < 3 cm (1.2 in)
thick, often not imbedded into the mineral soil surface, and are therefore regularly washed away by
flood waters. This geomorphic unit is often flooded even during relatively minor increases in river
stage.
Braided Active Overbank
Deposit (Fboa)
Vertical accretion deposits on low portions of the overbank environment in close proximity to the
braided river channels. The deposits are comprised of silts and fine sands that have a laminar,
interbedded structure formed by changes in velocity and deposition during waxing and waning
floods. Frequent flooding and sedimentation prevents organic matter accumulation. Fine-grained
material must be > 40 cm (16 in) thick and organic layers comprise less than 10% of the thickness.
Braided Coarse Active
Channel Deposit (Fbrac)
Braided Active Channel Deposit in which > 50% of the soil in the upper 40 cm (16 in) is loamy fine
sand or coarser. These deposits also include all rocky soils, regardless of dominant texture, with >
15% coarse fragments, typically gravels. These deposits primarily occur on mid-channel and lateral
bars.
Braided Fine Active
Channel Deposit (Fbraf)
Braided Active Channel Deposit in which > 50% of mineral soil in the upper 40 cm (16 in) is
dominated by textures that are loamy very fine sand or finer, and coarse fragments are either
absent, present at < 15% abundance, or present at >15% abundance but at a thickness < 50% of
the mineral soil in the upper 40 cm (16 in) . On mid-channel or lateral bars, these deposits can occur
in the concave microtopography of scour channels and ridges. These deposits also occur in former
meander channels, swales or guts.
Braided Fine Inactive
Channel Deposit (Fbrif)
Braided Inactive Channel Deposits in which > 50% of mineral soil in the upper 40 cm (16 in) is
dominated by textures that are loamy very fine sand or finer; coarse fragments are either absent,
present at < 15% abundance, or present at >15% abundance but at a thickness < 50% of the
mineral soil in the upper 40 cm (16 in). On mid-channel or lateral bars, these deposits can occur in
the concave microtopography of scour channels and ridges. These deposits also occur in former
river channels, swales or guts.
Braided Inactive
Channel Deposit (Fbri)
Lateral accretion deposits in inactive (“high water” or “cut-off”) channels of braided rivers that are
flooded only during high-water events. Riverbed material often has a thick layer (> 20 cm [8 in]) of
fine-grained material over the coarse channel deposits and surface is usually vegetated.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 39 June 2014
Geomorphic Unit Description
Braided Inactive
Overbank Deposit (Fboi)
Vertical accretion deposits formed on higher portions of the overbank environment in close proximity
to braided river channels. Areas are subject to infrequent flooding (approx. every 5–25 years).
Comprised of interbedded organics, silts and fine sands. Deposits are > 40 cm (16 in) thick and
organic layers comprise 10–40% of the top 40 cm (16 in).
Channel Fen (Ofc) Similar to Organic Fen but specific to fens forming in abandoned river channels.
Gravel fill (Hfg) Deposits of gravel and other fill primarily used for the creation of roads and pads.
Meander Abandoned
Channel Deposit (Fmrb)
Lateral accretion deposits of a meander floodplain that no longer is associated with the present
fluvial regime or where flooding is sufficiently infrequent that fluvial sediments form a negligible
component of surface material. On flat interfluve areas, surface materials are dominated by gravel or
sand and lack fine-grained overbank deposits. In concave areas, such as scour channels and former
river channels, the deposits are dominated by very fine sands and silts. Abandoned channel
deposits are > 40 cm (16 in) thick, and organic layers comprise > 40% of the top 40 cm (16 in).
Meander Abandoned
Overbank Deposit
(Fmob)
Vertical accretion deposits of meandering floodplains that no longer are associated with the present
fluvial regime or where flooding is sufficiently infrequent that fluvial sediments form a negligible
component of surface material. Surface materials often include a mixture of fluvial, eolian, and
organic materials, but typically are highly organic. The deposits are > 40 cm (16 in) thick, and
organic layers comprise > 40% of the top 40 cm (16 in).
Meander Active Channel
Deposit (Fmra)
Lateral accretion deposits formed in meandering channels that wind freely in regular to irregular,
well-developed, S-shaped curves. Channels range from highly sinuous to only slightly meandering.
Riverbed material can range from gravels and cobbles to gravelly-cobbly sand, and lateral accretion
deposits along point bars typically are sandier. Surface organic materials are absent, or if present
are not imbedded into the mineral soil surface, and are therefore often washed away by flood
waters. These deposits occur primarily on mid-channel and lateral bars.
Meander Active
Overbank Deposit
(Fmoa)
Vertical accretion deposits on low portions of the overbank environment in close proximity to the
meandering river channels. The deposits are comprised of silts and fine sands that have a laminar,
interbedded structure formed by changes in velocity and deposition during waxing and waning
floods. Frequent flooding and sedimentation prevents organic matter accumulation. Fine-grained
material must be > 40 cm (16 in) thick and organic layers comprise less than 10% of the thickness.
Meander Coarse Active
Channel Deposit
(Fmrac)
Meander Active Channel Deposits in which > 50% of the soil in the upper 40cm (16 in) is loamy fine
sand or coarser. These deposits also include all rocky soils, regardless of dominant texture, with >
15% coarse fragments, typically gravels. These deposits primarily occur on mid-channel or lateral
bars.
Meander Fine
Abandoned Channel
Deposit (Fmrbf)
Meander Abandoned Channel Deposits in which > 50% of mineral soil in the upper 40 cm (16 in) is
dominated by textures that are loamy very fine sand or finer, and coarse fragments are either
absent, present at < 15% abundance, or present at > 15% abundance but at a thickness <50% of
the mineral soil in the upper 40 cm (16 in). On interfluves or flat banks, these deposits are located in
scour channel and ridge microtopography; they also occur in former river channels, swales or guts.
Meander Fine Active
Channel Deposit (Fmraf)
Meander Active Channel Deposits in which > 50% of mineral soil in the upper 40 cm (16 in) is
dominated by textures that are loamy very fine sand or finer, and coarse fragments are either
absent, present at < 15% abundance, or present at > 15% abundance but at a thickness < 50% of
the mineral soil in the upper 40 cm (16 in). On mid-channel or lateral bars, these deposits can occur
in the concave microtopography of scour channels and ridges. These deposits also occur in former
river channels, swales or guts.
Meander Fine Inactive
Channel Deposit (Fmrif)
Meander Inactive Channel Deposit in which > 50% of mineral soil in the upper 40 cm (16 in) is
dominated by textures that are loamy very fine sand or finer, and coarse fragments are either
absent, present at < 15% abundance, or present at > 15% abundance but at a thickness < 50% of
the mineral soil in the upper 40 cm (16 in). On mid-channel or lateral bars, these deposits can occur
in the concave microtopography of scour channels and ridges. These deposits also occur in former
river channels, swales or guts.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 40 June 2014
Geomorphic Unit Description
Meander Inactive
Channel Deposit (Fmri)
Mixed lateral and vertical accretion deposits in inactive (“high water” or “cut-off”) channels of
meander rivers that are flooded only during high-water events. Riverbed material often has a thin
layer of fine-grained material over the coarse channel deposits and surface is usually vegetated.
Meander Inactive
Overbank Deposit
(Fmoi)
Vertical accretion deposits formed on higher portions of the overbank environment in close proximity
to meandering river channels. Areas are subject to infrequent flooding (approx. every 5–25 years).
Comprised of interbedded organics, silts and fine sands. Deposits are > 40 cm (16 in) thick and
organic layers comprise 10–40% of the top 40 cm (16 in).
Old Alluvial Terrace
(Fto)
Relatively flat surfaces resulting from the dissection of former floodplain areas. Old terraces are
typically higher in elevation than Recent Alluvial Terraces (relative to the present day river channel),
are never subject to flooding under the current regime, and were formed previous to the end of the
Little Ice Age (> 150 years). Deposits consist of gravelly sand, sand, silty sand, and peat. Deposits
usually are overlain by eolian silt and sand and have moderately thick organic horizons. Lack of
flooding is indicated by the presence of E- and/or Bs-horizons and the lack of stratified silts, sands,
and organics in the upper 40 cm (16 in) of the soil profile.
Organic Fen (Of) Minerotrophic wetlands with thick (> 40 cm [16 in]) organic matter accumulations developed in
basins fed by mineral-rich surface water or groundwater. Water chemistry is typically circumneutral
(pH 5.5–7.3) or alkaline (pH > 7.3), and dissolved minerals are present at moderate to high
concentrations (electrical conductivity > 100 µS). The surface is flat and the water table is near the
surface. Organic matter is dominated by fibric peat of sedges, horsetails, and willow leaves.
Recent Alluvial Terrace
(Ftr)
Relatively flat surfaces resulting from the dissection of former floodplain areas. Recent terraces are
typically lower in elevation than Old Alluvial Terraces (relative to the present day river channel), are
never subject to flooding under the current regime, and were formed since the end of the Little Ice
Age (< 150 years). Deposits consist of gravelly sand, sand, silty sand, and peat. Deposits usually
are overlain by eolian silt and sand and have moderately thick organic horizons. Lack of flooding is
indicated by the presence of E- and/or Bs-horizons and the lack of stratified silts, sands, and
organics in the upper 40 cm (16 in) of the soil profile.
Upland, undifferentiated
(U)
These include small areas of upland hillsides and mountain slopes directly adjacent to riverine areas
that were not assigned a specific geomorphic unit in the Integrated Terrain Unit (ITU) mapping.
AQUATIC
Upper Perennial Glacial
River (Wrug)
Permanently flooded channels of freshwater rivers where the gradient is relatively steep; substrate
consists of rock, cobble, gravel, and sand; and discharge and water quality are affected by glacial
meltwater. River water may appear discolored from high concentrations of suspended sediments
during mid-summer. Rivers experience peak flooding during mid-summer.
Lowland Headwater
Stream (Wrhl)
Permanently flooded first order tributaries of higher order creeks and rivers, typically low gradient
and meandering.
Riverine Slough (Wrsl) A sluggish channel of water, such as a side channel of a river, in which water flows slowly through
low, swampy ground, or a section of an abandoned river channel which may contain stagnant water
and occurs in a flood plain.1
Shallow Connected
Beaver Pond (Wlscv)
A shallow (< 1.5 m [5 ft]) pond on created by the impoundment of water behind a beaver dam that is
connected to the main channel of a river by a small stream (i.e., fish may freely pass from the river
into the pond, particularly during high-water events).
Notes
1 From Glossary of Landform and Geologic Terms (USDA NRCS 2013).
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 41 June 2014
Table 5-5. Classification and Description of Surface Form Classes in the Middle Susitna River Portion of the Riparian
Vegetation Study Area, Susitna-Watana Hydroelectric Project, 2013.
Surface Form Class Description
Bar A ridge-like accumulation of sand, gravel, or other alluvial material formed in the channel,
along the banks, or at the mouth of a stream where a decrease in velocity induces
deposition.1
Basins Or Depressions (B) An area that is concave in all directions. Often collects water. This class includes kettle
holes, formed by the melting of a glacial ice mass formed on the surface of glacial drift.
Braided Channels And Interfluvs (Xcb) Complex surface form characteristic of active channel deposits along braided rivers in
which narrow (3–10 m [10–33 ft]), shallow (0.1–0.5 m [0.3–1.6 ft]) braided channels are
intermixed with narrow interfluvs or flat banks.
Channel, Swale Or Gut (Fc) Low-lying concave portions of the floodplain developed from river scouring. Tend to be
water gathering.
Flood Basin (Ff) Flat, distal portion of a floodplain behind a levee. Surface tends to impound water.
Human Modified Areas of the landscape affected by human activities.
Ice-rafted debris (Mid) Mounds and otherwise undulating terrain created by materials, typically gravelly-cobbly
sands and down wood, rafted into an area by ice during breakup.
Ice-shoved ridge (Mir) Ridges of surficial materials, typically gravelly and cobbly sands, created by the “bull-
dozing” effect of large chunks of ice forced downstream during breakup in the spring of
the year. This surface form is often associated with deep pits in the ground surface from
which the ridge material was excavated.
Interfluv Or Flat Bank (Fi) Flat areas on floodplains that are slightly raised above adjacent lower active or paleo-
channels.
Lateral Bar (Fbl) Flat to gently sloping, oblong or linear shaped shoal forming immediately forming along
the lateral margins of an active channel of a river. See also “Bar”.
Mid-Channel Bar (Fbm) Flat to gently sloping, oblong or linear shaped shoal forming in the middle of a river (i.e.,
islands). Mid-channel bars are surrounded on all sides by perennially flowing river water,
or are surrounded on at least three sides by active channel deposits, with the river on the
fourth side. See also “Bar”.
Nonpatterned (N) Flat areas of the landscape where surface form features are absent.
Peat mounds (Mpm) Low (< 0.5 m [1.6 ft]), round or oblong mounds, 0.2 to 1.5 m (0.7 to 5 ft] in diameter,
often composed of sedge and Sphagnum moss and formed by differential growth rates.
Also referred to as turf hummocks.2
Point Bar (Fbp) Flat to gently sloping, crescent shaped shoal forming immediately adjacent to a river,
usually forming on the inside of a bend.
Ripples (Dr) An undulating surface of alternating, subparallel, small-scale ridges and depressions,
commonly composed of loose sand. It is produced on land by wind and under water by
the agitation of water by currents or wave action, and generally tends at right angles or
obliquely to the direction of flow of the moving fluid.1
River Or Stream (R) General surface form characteristic assigned to rivers, a natural, freshwater waterbody of
considerable volume and generally with a permanent base flow, moving in a defined
channel; and streams, a body of running water of lower volume that moves under gravity
to progressively lower levels, in a relatively narrow but clearly defined channel on the
ground surface.1
Riverbed Cobbles or Boulders (Dc) Undulating surface form of active channel deposits created by river cobbles, stones, and
boulders.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 42 June 2014
Surface Form Class Description
Scour channels-ridges (Ds) Complex surface form characteristic of active channel deposits along braided rivers in
which narrow (< 3 m [10 ft]), deeply incised (0.5–1.0 m [1.6–3.3 ft]) channels are
intermixed with narrow, steep ridges formed from alluvial material.
Terrace (Ft) Flat, bench-like landforms on inactive and abandoned floodplain surfaces. Terraces are
associated with the Abandonded Overbank (both meander and braided) and Recent
Alluvial Terrace geomorphic units. Terraces are differentiated from the surface form class
Interfluv or Flat Bank by featuring a short (0.5–1.5 m [1.6–5 ft]), steep, distinct break in
elevation (‘riser’) between the floodplain surface and the terrace ‘bench’.
Tree mounds (Ml) Mounds and on the forest floor created by downed logs and root balls.
Undifferentiated mounds (Mu) Low (0.2–1.0 m [0.7–3.3 ft]) earthen mounds of unknown origin and composition.
Upland, undifferentiated (U) These include small areas of upland hillsides and mountain slopes directly adjacent to
riverine areas that were not assigned a specific surface form in the ITU mapping.
Water Bodies (W) Freshwater bodies of water, including ponds, streams, and rivers.
Notes
1 From Glossary of Landform and Geologic Terms (USDA NRCS 2013)
2 From Permafrost – A guide to frozen ground in transition (Davis 2001)
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 43 June 2014
Table 5-6. Classification and Description of Vegetation Classes in the Middle Susitna River Portion of the Riparian
Vegetation Study Area, Susitna-Watana Hydroelectric Project, 2013.
Vegetation Class Description
Balsam Poplar
Woodland (Fbwp)
Riverine woodlands (10–25% tree cover) dominated by large (> 0.75 m [2.5 ft] DBH) Populus
balsamifera. Commonly associated species include Alnus tenuifolia, Equisetum arvense, Alnus crispa,
Viburnum edule, Ribes triste, Galium triflorum, and Matteuccia struthiopteris.
Barren (Bbg) Barren sites (e.g., active cobble bars) where vegetation is absent or nearly so (< 5% cover).
Black Spruce Woodland
(Fnwbs)
Lowland woodlands (10–25% tree cover) dominated by Picea mariana. Commonly associated species
include Chamaedaphne calyculata, Ledum decumbens, Rubus chamaemorus, Oxycoccus
microcarpus, Vaccinium uliginosum, Empetrum nigrum, Drosera rotundifolia, Sphagnum fuscum, and
S. angustifolium
Bluejoint Meadow
(Hgmb)
Graminoid meadows dominated by Calamagrostis canadensis. Other associated species occur at low
abundance (~1–3%), including Epilobium angustifolium, Rubus idaeus, Artemisia tilesii, Geum
macrophyllum, and Galium boreale.
Bluejoint-Herb (Hgmbh) Graminoid meadows co-dominated by Calamagrostis canadensis and a diversity of associated forb
species. Commonly associated species include Heracleum lanatum, Polemonium acutiflorum,
Mertensia paniculata, Thalictrum sparsiflorum, and Epilobium angustifolium.
Bluejoint-Shrub
(Hgmbs)
Graminoid meadows co-dominated by Calamagrostis canadensis and a diversity of associated shrub
species. Total shrub cover is less than 25%. Commonly associated species include Alnus tenuifolia,
Rubus idaeus, Rosa acicularis,Viburnum edule, Ribes triste, Athyrium filix-femina, Gymnocarpium
dryopteris, and Mertensia paniculata.
Closed Balsam Poplar
Forest (Fbcp)
Closed (> 60% tree cover) riverine forests dominated by Populus balsamifera. Commonly associated
species include Viburnum edule, Rosa acicularis, Alnus crispa, Alnus tenuifolia, Artemisia tilesii, and
Aster sibiricus.
Closed Balsam Poplar-
White Spruce Forest
(Fmcpws)
Closed (> 60% tree cover) riverine forests co-dominated by Populus balsamifera and Picea glauca.
Commonly associated species include Viburnum edule, Rosa acicularis, Ribes triste, Calamagrostis
canadensis, and Pyrola asarifolia.
Closed Low Rose Shrub
(Slcr)
Similar to Open Low Rose Shrub, but with a closed (> 75% shrub cover) shrub canopy.
Closed Paper Birch
Forest (Fbcb)
Closed (> 60% tree cover) riverine forests dominated by Betula papyrifera. Commonly associated
species include Viburnum edule, Rosa acicularis, Ribes triste, Calamagrostis aanadensis,
Gymnocarpium dryopteris, Equisetum arvense, and E. pratense
Closed Poplar
Woodland-Alder Tall
Shrub (Sfcpa)
Riverine closed (> 75% shrub cover) stands of Populus balsamifera saplings co-dominant with alder
tall shrub (> 1.5 m [5 ft]) including Alnus sinuata, A. tenuifolia, and A. crispa. Commonly associated
species include Artemisia tilesii, Equisetum variegatum, and Agropyron boreale.
Closed Poplar
Woodland-Willow Tall
Shrub (Sfcpw)
Riverine closed (> 75% shrub cover) stands of Populus balsamifera saplings co-dominant with willow
tall shrub (> 1.5 m [5 ft]) including Salix alaxensis, S. barclayi, S. lasiandra, and S. sitchensis.
Commonly associated species include Artemisia tilesii, Equisetum variegatum, and Agropyron boreale.
Closed Tall Alder Shrub
(Stca)
Riverine closed (> 75% shrub cover) tall shrub (> 1.5 m [5 ft]) stands dominated or co-dominated by
Alnus tenuifolia, A. crispa, and A. sinuata. Commonly associated species include Equisetum
variegatum.
Closed Tall Alder-
Willow Shrub (Stcaw)
Riverine closed (> 75% shrub cover) tall shrub (> 1.5 m [5 ft]) co-dominated by alders and willows,
including Alnus crispa, A. tenuifolia, Salix alaxensis, and S. barclayi. Commonly associated species
include Cinna latifolia, Heracleum lanatum, Matteuccia struthiopteris, Mertensia paniculata, and Rosa
acicularis.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 44 June 2014
Vegetation Class Description
Closed Tall Willow
Shrub (Stcw)
Riverine closed (> 75% shrub cover) tall shrub (> 1.5 m [5 ft]) co-dominated by Salix barclayi and/or S.
alaxensis. Commonly associated species include S. lasiandra, Matteuccia struthiopteris, Alnus
tenuifolia, Viburnum edule, Heracleum lanatum, Equisetum arvense, Gymnocarpium dryopteris,
Epilobium angustifolium, Ribes triste, Streptopus amplexifolius, Calamagrostis canadensis, and
Mertensia paniculata
Disturbance Complex Areas on the landscape with 3 or more vegetation types resulting from human disturbance.
Dryas Dwarf Shrub
Tundra (Sddt)
Riverine dwarf shrub dominated by Dryas drummondii. Commonly associated species include
Shepherdia canadensis, Epilobium latifolium, Equisetum variegatum, and Stereocaulon sp.
Dwarf Black Spruce
Woodland (Sfwbs)
Lowland dwarf (< 10 m [33 ft] in height) needleleaf forests dominated by Picea mariana. The trees in
these stands are dwarf due to harsh environmental conditions, including high water table or
permafrost. Commonly associated species include Rubus chamaemorus, Empetrum nigrum, Ledum
decumbens, Betula nana, Oxycoccus microcarpus, Vaccinium uliginosum, Drosera rotundifolia,
Andromeda polifolia, Sphagnum fuscum, and S. angustifolium.
Ferns (Hfmc) Riverine herbaceous meadows dominated (> 75% cover) by the fern Matteuccia struthiopteris, which
forms nearly monotypic stands. Commonly associated species that occur in low abundance (< 3%
cover) include Alnus tenuifolia, Equisetum arvense, Mertensia paniculata, Trientalis europaea, Adoxa
moschatellina, Delphinium glaucum, Galium boreale, G. triflorum, and Streptopus amplexifolius.
Fresh Herb Marsh
(Hfwfh)
Riverine and lowland marshes dominated by aquatic forbs, including Equisetum fluviatile, Potentilla
palustris, and/or Menyanthes trifoliata. Commonly associated species include Cicuta mackenzieana
and Carex utriculata.
Fresh Sedge Marsh
(Hgwfs)
Riverine and lowland marshes dominated by sedges, namely Carex utriculata. Commonly associated
species include Glyceria pauciflora.
Fresh Water (Wf) Permanently flooded non-vegetated waterbodies, included in this class are non-vegetated Lower
Perennial River, glacial; Lowland Headwater Stream; Riverine Slough, and Shallow Connected Beaver
Pond. This class may include some waterbodies with submerged vegetation that was not mappable.
Large Umbel (Hfmu) Lowland and riverine herbaceous meadows dominated by Heracleum lanatum. These meadows
feature a rich-array of forbs, including Epilobium angustifolium, Polemonium acutiflorum, Mertensia
paniculata, Thalictrum sparsiflorum, Delphinium glaucum, Botrychium lunaria, B. virginianum,
Geranium erianthum, Athyrium filix-femina, Adoxa moschatellina, Ranunculus abortivus, and Urtica
gracilis.
Open Balsam Poplar
Forest (Fbop)
Open (25–60% tree cover) riverine forests dominated by Populus balsamifera. Commonly associated
species include Alnus tenuifolia, Viburnum edule, Mertensia paniculata, Equisetum arvense, and
Calamagrostis canadensis.
Open Black Spruce
Forest (Fnobs)
Lowland forests with an open (25–60% tree cover) canopy dominated by Picea mariana. Commonly
associated species include Ledum groenlandicum, Vaccinium uliginosum, Empetrum nigrum,
Vaccinium vitis-idaea, Rubus chamaemorus, Cornus Canadensis, Oxycoccus microcarpus, and
Hylocomium splendens.
Open Low Alder-Willow
Shrub (Sloaw)
Riverine open (25–75% shrub cover) low shrub (< 1.5 m [5 ft]) co-dominated by Salix alaxensis and S.
barclayi, with occasional occurrences of S. lasiandra. Commonly associated species include Artemisia
tilesii, Epilobium angustifolium, Equisetum variegatum, and E. arvense.
Open Low Shrub Birch-
Ericaceous Shrub Bog
(Slobb)
Bogs co-dominated by Sphagnum mosses, Betula nana, and variety of ericaceous shrubs, including
Vaccinium uliginosum and Chamaedaphne calyculata. Commonly associated species include
Oxycoccus microcarpus, Drosera rotundifolia, Carex chordorrhiza, and C. limosa
Open Low Ericaceous
Shrub Bog (Sloeb)
Bogs co-dominated by Sphagnum mosses, including Sphagnum angustifolium, S. magellanicum,and
S. warnstorfii, and low (< 1.5 m [5 ft]) ericaceous shrubs, including Chamaedaphne calyculata and
Myrica gale. Commonly associated species include Oxycoccus microcarpus, Carex chordorrhiza,
Equisetum fluviatile, and Drosera rotundifolia
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 45 June 2014
Vegetation Class Description
Open Low Rose Shrub
(Slor)
Riverine open (25–75% shrub cover) low shrub (< 1.5 m [5 ft]) dominated by Rosa acicularis.
Commonly associated species include Calamagrostis canadensis, Rubus idaeus, Viburnum edule,
Mertensia paniculata, Equisetum arvense, Ribes triste, Epilobium angustifolium, Alnus tenuifolia, and
Thalictrum sparsiflorum,
Open Low Willow Shrub
(Slow)
Riverine open (25–75% shrub cover) low shrub (< 1.5 m [5 ft]) co-dominated by Salix barclayi and S.
alaxensis. Commonly associated species include Calamagrostis Canadensis, Mertensia paniculata,
Equisetum arvense, Rubus idaeus, Epilobium angustifolium, Galium triflorum, and Thalictrum
sparsiflorum.
Open Paper Birch
Forest (Fbob)
Similar to Closed Paper Birch except forest canopy is open (25–60% tree cover).
Open Paper Birch-
Balsam Poplar-Spruce
Forest (Fmobps)
Open (25–60% tree cover) riverine forests co-dominated by Populus balsamifera, Betula
papyrifera,and Picea glauca. Commonly associated species include Rosa acicularis, Viburnum edule,
Cornus Canadensis, Hylocomium splendens, and Pleurozium schreberi.
Open Poplar Woodland-
Alder Tall Shrub (Sfopa)
Riverine open (25–75% shrub cover) stands of Populus balsamifera saplings co-dominate with tall
alder shrub (> 1.5 m [5 ft]) including Alnus sinuata, A. tenuifolia, and A. crispa. Commonly associated
species include Hedysarum alpinum,Calamagrostis Canadensis, Artemisia tilesii, Castilleja caudate,
Platanthera hyperborean, and Ceratodon purpureus.
Open Poplar Woodland-
Alder-Willow Tall Shrub
(Sfopaw)
Riverine open (25–75% shrub cover) stands of Populus balsamifera saplings co-dominate with tall
alder and willow shrub (> 1.5 m [5 ft]) including Alnus sinuata, A. tenuifolia, A. crispa, Salix alaxensis,
and S. barclayi. Commonly associated species include Artemisia tilesii, Equisetum variegatum, and
Agropyron boreale.
Open Poplar Woodland-
Willow Tall Shrub
(Sfopw)
Riverine open (25–75% shrub cover) stands of Populus balsamifera saplings co-dominate with tall
willow shrub (> 1.5 m [5 ft]) including Salix alaxensis, S. barclayi, and S. sitchensis. Commonly
associated species include Hedysarum alpinum, Astragalus alpinus, Equisetum variegatum, and
Ceratodon purpureus.
Open Spruce-Balsam
Poplar Forest (Fmosp)
Similar to Closed Balsam Poplar-White Spruce except forest canopy is open (25–60% tree cover).
Open Spruce-Paper
Birch Forest (Fmosb)
Upland, lowland, or riverine forests with an open (25–60% cover) canopy co-dominated by Betula
papyrifera and Picea glauca. Commonly associated species include Viburnum edule, Rosa acicularis,
Ribes triste, Streptopus amplexifolius, Dryopteris dilatata americana, Trientalis europaea arctica,
Epilobium angustifolium, and Lycopodium annotinum.
Open Tall Alder Shrub
(Stoa)
Riverine and lowland stands of open (25–75% shrub cover) tall shrub (> 1.5m [5 ft]) dominated or co-
dominated by Alnus sinuata, A. tenuifolia, and/or A. crispa. Commonly associated species include
Salix alaxensis, Artemisia tilesii, Populus balsamifera, Salix barclayi, and Calamagrostis canadensis.
Open Tall Alder-Willow
Shrub (Stoaw)
Riverine open (25–75% shrub cover) tall shrub (> 1.5 m [5 ft]) co-dominated by alders and willows,
including Alnus crispa, A. tenuifolia, Salix alaxensis, and S. barclayi. Commonly associated species
include Mertensia paniculata, Rubus idaeus, Epilobium angustifolium, and Equisetum arvense. Picea
glauca seedlings are commonly found in the understory of this vegetation type.
Open Tall Willow Shrub
(Stow)
Riverine open (25–75% shrub cover) tall shrub (> 1.5 m [5 ft]) by willow, namely Salix barclayi.
Calamagrostis canadensis, Rosa acicularis, Gymnocarpium dryopteris, Rubus idaeus, Alnus tenuifolia.
Athyrium filix-femina, Galium triflorum, and Heracleum lanatum.
Open White Spruce
Forest (Fnows)
Riverine forest with an open (25–60% tree cover) canopy dominated Picea glauca. Commonly
associated species include Viburnum edule, Mertensia paniculata, Calamagrostis canadensis, Alnus
tenuifolia, Rosa acicularis, and Ptilium crista-castrensis.
Paper Birch Woodland
(Fbwb)
Riverine woodlands (10–25% tree cover) dominated by Betula papyrifera. Commonly associated
species are similar to Closed Paper Birch.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 46 June 2014
Vegetation Class Description
Partially Vegetated
(Bpv)
Sites where vegetation is poorly established and total cover of live plants is 5–30%. Commonly
associated species include Salix alaxensis, Populus balsamifera, Artemisia tilesii, Equisetum
variegatum, Astragalus alpinus, Epilobium latifolium, and Dryas drummondii.
Riverine Complex (Xr) To be described.
Spruce-Balsam Poplar
Woodland (Fmwsp)
Riverine woodlands (10–25% tree cover) co-dominated by Populus balsamifera and Picea glauca.
Commonly associated species include Calamagrostis canadensis, Viburnum edule, Alnus tenuifolia,
Ribes triste, and Equisetum arvense.
Spruce-Paper Birch
Woodland (Fmwsb)
Upland, lowland, or riverine woodlands (10–25% tree cover) co-dominated by Betula papyrifera and
Picea glauca. Commonly associated species are similar to Open Spruce-Paper Birch.
Subarctic Lowland
Graminoid-Herb Wet
Meadow (Hgwgh)
Lowland wet meadows and fens co-dominated by sedges and aquatic forbs, including Carex utriculata.
C. aquatilis, Potentilla palustris,and Menyanthes trifoliata. Commonly associated species including
Equisetum fluviatile, Carex pluriflora, Carex canescens, and Calliergon sp.
Subarctic Lowland
Grass Wet Meadow
(Hgwg)
Lowland wet meadows and fens dominated by Calamagrostis canadensis. Commonly associated
species include Equisetum fluviatile, Potentilla palustris, Alnus tnuifolia, Carex utriculata, and
C. aquatilis.
Subarctic Lowland Herb
Bog Meadow (Hfwhb)
Bogs co-dominated by Sphagnum mosses and aquatic forbs, including Potentilla palustris, Equisetum
fluviatile, and Menyanthes trifoliata. Commonly associated species include Carex utriculata, Carex
sitchensis, Chamaedaphne calyculata, and Salix fuscescens.
Subarctic Lowland
Sedge Bog Meadow
(Hgwsb)
Bogs dominated by wet sedges, including Trichophorum caespitosum, Carex chordorrhiza, C.
rotundata, C. aquatilis, C. limosa, and C. pauciflora. Common associated species include Betula nana,
Andromeda polifolia, Myrica gale, Drosera rotundifolia, Chamaedaphne calyculata, Oxycoccus
microcarpus, Sphagnum fuscum, S. magellanicum, and S. angustifolium.
Subarctic Lowland
Sedge Wet Meadow
(Hgwsl)
Sedge dominated wet meadows in which Carex aquatilis, C. canescens, C. utriculata, C. sitchensis
and/or Scirpus microcarpus are dominant. Commonly associated species include Potentilla palustris,
Equisetum fluviatile, and Cicuta mackenzieana.
Subarctic Lowland
Sedge-Moss Bog
Meadow (Hgwsmb)
Bogs co-dominated by Sphagnum mosses, including S. fuscum, S. magellanicum, S. angustifolium,
and wet sedges, including Carex chordorrhiza, C. tenuiflora,and C. limosa. Commonly associated
species include Betula nana, Drosera rotundifolia, Eriophorum angustifolium, Andromeda polifolia, and
Oxycoccus microcarpus.
Upland, undifferentiated
(U)
To be described.
Wet Forb Meadow
(Hfw)
Lowland wet meadows and fens dominated by Equisetum fluviatile or E. arvense. Commonly
associated species include Carex utriculata, Poa palustris, and Potentilla palustris.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 47 June 2014
Table 5-7. Classification and Description of Disturbance Classes in the Middle Susitna River Portion of the Riparian
Vegetation Study Area, Susitna-Watana Hydroelectric Project, 2013.
Class Description
Absent, None (A) No recent (within 1–3 years) disturbance.
Fluvial (Ngf) Recent (1–3 years old), undifferentiated disturbance related to deposition or erosion of sediments due
to riverine processes.
Fluvial Deposition
(Ngfd)
Recent (1–3 years old) deposition of sediment related to riverine flooding.
Fluvial Erosion/channel
migration (Ngfe)
Recent (1–3 years old) erosion of sediment related to riverine flooding.
Geomorphic Process
(Ng)
Recent disturbance (1–3 years old) caused by an unknown geomorphic process.
Gravel Fill (Hfg) Areas on the landscape where covered by gravel fill (e.g., Alaska Railroad)
Ice Bulldozing (Ngi) Recent (1–3 years) disturbance from ice during spring break up events, including shearing of trees and
shrubs; tree ice-scars; gouging, mounding, and erosion of floodplain surfaces; and deposition of ice-
rafted sediment and coarse fragments.
Residential
Development (Hdr)
Areas of the landscape where human residences have been built.
Undifferentiated
Clearing (Hc)
Areas of the landscape where vegetation has been cleared and which the intent of the clearing in
unknown.
Wind (Nwd) Recent (1–3 years old) wind thrown trees characterized by down logs and upturned root wads with
exposed mineral soil.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 48 June 2014
Table 5-8. Classification and Description of Poplar Size Classes in the Middle Susitna River Portion of the Riparian
Vegetation Study Area, Susitna-Watana Hydroelectric Project, 2013.
Class Description
Pole (P) Diameter at Breast Height (DBH) ranges between 5 and 30 cm (2 and 12 in). The upper DBH limit of this
class was determined based on susceptibility to shearing by ice during spring breakup. Trees smaller
than this diameter are more prone to shearing than larger trees.
Timber(T) DBH ranges between 31 and 90 cm (12 and 35 in). The lower DBH limit of this class was determined
based on susceptibility to shearing by ice during spring breakup. Trees larger than this diameter are less
prone to shearing and are more likely to deflect ice than smaller trees.
Large Timber (L) DBH > 90 cm (35 in). Trees larger than the minimum diameter of this class are preferred by black bears
for den trees and by raptors for nest platforms.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 49 June 2014
Table 5.1-1. List of Preliminary Ecotypes Classified Using 2012 Field Data and Mapping Data for FA-104 (Whiskers
Slough), FA-115 (Slough 6A), and FA-128 (Slough 8A), Middle Susitna River, Riparian Vegetation Study Area, Susitna-
Watana Hydroelectric Project, 2013.
Ecotype FA Map Class1 2012 Plot Data2
Terrestrial
Human Modified X
Lowland Loamy Birch Forest X X
Lowland Loamy Ostrich Fern Meadow X
Lowland Organic-rich Bluejoint-Herb Meadow X
Lowland Organic-Rich Wet Spruce Forest X
Lowland Peaty Wet Birch Low Shrub Bog X
Riverine Complex X
Riverine Gravelly Wormwood-Horsetail Barrens and Partially Vegetated X X
Riverine Loamy Birch Forest X X
Riverine Loamy Large Umbel Meadow X
Riverine Loamy Ostrich Fern Meadow X X
Riverine Loamy Spruce-Birch Forest X X
Riverine Sandy Alder-Willow Tall Shrub X X
Riverine Sandy Balsam Poplar Sapling-Alder-Willow Tall Shrub X X
Riverine Sandy Bluejoint-Herb Meadow X X
Riverine Sandy Pole-sized Balsam Poplar Forest X X
Riverine Sandy Raspberry-Rose Low Shrub X
Riverine Sandy Spruce Forest X
Riverine Sandy Timber-sized Balsam Poplar Forest X X
Riverine Sandy-Loamy Balsam Poplar Large Tree Forest X X
Riverine Sandy-Loamy Spruce-Balsam Poplar Forest X
Riverine Wet Sedge-Forb Marsh X X
Upland Loamy Spruce-Birch Forest X X
Upland Poplar Forest
Upland, undifferentiated X
Aquatic
Lowland Headwater Stream X
Riverine Circumneutral Beaver Pond X X
Riverine Circumneutral Glacial River X X
Riverine Slough X
Notes:
1 Indicates whether a given ecotype was mapped in FA-104 (Whiskers Slough), FA-115 (Slough 6A), or FA-128
(Slough 8A) (X) or not (blank).
2 Indicates whether an ecotype class was classified based on 2012 field plot data (X) or was developed as a
temporary map class until 2013 data are incorporated into the ecotype analysis (blank).
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 50 June 2014
Table 5.1-2. Classification and Description of Preliminary Ecotypes Identified in the Middle Susitna River, Riparian
Vegetation Study Area, Susitna-Watana Hydroelectric Project, 2013.
Ecotype Description
Human Modified Areas of the landscape affected human activities, including gravel fill, excavations, vegetation
clearing, and residential development.
Lowland Headwater Stream Low-gradient, meandering tributary streams of the Susitna River, e.g., Whisker’s Slough in
Focus Area 104.
Lowland Loamy Birch Forest This ecotype includes Open and Closed Paper Birch forests and occurs on Meander
Abandoned Overbank Deposits. Soils are loamy and moist. Tree mounds are common
microtopographic features associated with this ecotype. Floristic classes included in this
ecotype include Betula papyrifera/Ribes triste/Gymnocarpium dryopteris.
Lowland Loamy Ostrich Fern
Meadow
No plot data was collected for this ecotype in 2012. This ecotype was mapped in the Middle
Susitna River on Meander Abandoned Overbank Deposits.
Lowland Organic-rich
Bluejoint-Herb Meadow
No plot data was collected for this ecotype in 2012. This ecotype was mapped in the Middle
Susitna River on Meander Abandoned Overbank Deposits and Meander Abandoned Channel
Deposits.
Lowland Organic-Rich Wet
Spruce Forest
This ecotype includes Open Spruce-Paper Birch Forest on wet, organic-rich soils on alluvial
terraces. The hydrology of this ecotype along the middle Susitna River is strongly influenced by
hillside seeps and springs. Floristic classes include Picea glauca-Betula papyrifera/Alnus
tenuifolia/Athyrium filix-femina.
Lowland Peaty Wet Birch Low
Shrub Bog
This ecotype includes Open Low Shrub Birch-Ericaceous Shrub Bog in bogs on alluvial
terraces. Soils are wet and organic-rich. Peat mounds are common microtopographic features
associated with this ecotype. Floristic classes include Betula nana/Oxycoccus
microcarpus/Sphagnum sp.
Riverine Circumneutral Beaver
Pond
This ecotype includes ponds formed due to impoundment of water by beaver dams which are
often located at the downstream end of inactive and abandoned river channels. Vegetation
typically is a complex of open water, aquatic bed, and forb and graminoid marshes.
Riverine Circumneutral Glacial
River
This ecotype includes the Susitna River.
Riverine Complex No plot data was collected in this ecotype in 2012 is a map class only. Riverine complex
includes areas on the Susitna River floodplain where there were 3 or more
geomorphic/vegetation classes that occurred adjacent to one another but none of the unique
types were large enough in areal extent to separate given the scale of mapping.
Riverine Gravelly Wormwood-
Horsetail Barrens and Partially
Vegetated
This ecotype includes barrens and partially vegetated riverine areas and is associated with the
geomorphic units Meander Active Channel Deposits and Braided Active Channel Deposits.
Soils are sandy and gravelly. This ecotype occurs on river bars where scour channels and
ridges are common microtopographic features. Floristic classes include Artemisia tilesii-
Equisetum variegatum.
Riverine Loamy Birch Forest This ecotype includes Open and Closed Paper Birch forests on Meander Inactive Overbank
Deposits. Soils are typically loamy with thin interbedded organic horizons. Tree mounds are
common microtopographic features associated with this ecotype. Floristic classes included in
this ecotype include Betula papyrifera/Ribes triste/Gymnocarpium dryopteris.
Riverine Loamy Large Umbel
Meadow
This ecotype includes Large Umbel Meadows on Meander Fine Inactive Channel Deposits and
Meander Inactive Overbank Deposits. Soils are loamy and moist. Floristic classes include
Heracleum lanatum-Thalictrum sparsiflorum-Botrychium lunaria.
Riverine Loamy Ostrich Fern
Meadow
One plot was sampled in 2012 and occurred on a Meander Inactive Overbank Deposit. Soils
were loamy with thin interbedded organic horizons. Given the low sample size in 2012 no
floristic class was determined for this ecotype.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 51 June 2014
Ecotype Description
Riverine Loamy Spruce-Birch
Forest
This ecotype includes Open Spruce-Paper Birch Forest, Open White Spruce Forest, and
Spruce-Paper Birch Woodland, and occurs on Meander Inactive Overbank Deposits. Soils in
this ecotype are loamy with thin interbedded organic horizons. Tree mounds are common
microtopographic features associated with this ecotype. Floristic classes include Betula
papyrifera-Picea glauca/Matteuccia struthiopteris and Picea glauca-Betula papyrifera/Alnus
tenuifolia/Athyrium filix-femina.
Riverine Sandy Alder-Willow
Tall Shrub
This ecotype includes Closed Tall Willow Shrub, Open Low WillowShrub, Open Tall Alder
Shrub, and Open Tall Alder-Willow Shrub, and occurs on Meander Fine Active Channel
Deposits. Soils are dominated by sands with thin interbedded silt layers throughout the upper
soil profile. Ice-rafted debris and Scour channels-ridges are common microtopographic features
associated with this ecotype. Floristic classes include Alnus tenuifolia-Salix barclayi-Salix
alaxensis and Alnus tenuifolia/Matteuccia struthiopteris.
Riverine Sandy Balsam Poplar
Sapling-Alder-Willow Tall
Shrub
This ecotype includes Closed Poplar Woodland-Alder Tall Shrub, Open Poplar Woodland-Alder
Tall Shrub, and Open Poplar Woodland-Willow Tall Shrub on Meander Fine Active Channel
Deposits and Braided Fine Active Channel Deposits. The vegetation in this ecotype is
characterized by poplar saplings, and mixed alder-willow tall shrub. Soils are sandy and
gravelly. This ecotype occurs on river bars where ice-rafted debris and scour channels-ridges
are common microtopographic features. This ecotype is frequently disturbed by ice scour
during spring break up. Floristic classes include Populus balsamifera/Shepherdia canadensis,
Populus balsamifera (seedling)-Salix alaxensis/Equisetum variegatum/Ceratodon purpureus,
and Populus balsamifera (sapling)/Salix alaxensis/Hedysarum alpinum.
Riverine Sandy Bluejoint-Herb
Meadow
This ecotype includes Bluejoint Meadow and Bluejoint-Herb, and occurs on Meander Fine
Inactive Channel Deposit and Braided Fine Inactive Channel Deposit. Soils are sandy with thin
interbedded layers of silt. Floristic classes include Calamagrostis canadensis-Epilobium
angustifolium-Heracleum lanatum.
Riverine Sandy Pole-sized
Balsam Poplar Forest
This ecotype includes Closed Poplar Woodland-Alder Tall Shrub and Open Balsam Poplar
Forest. Poplar in this ecotype are typically pole-sized (5–30 cm [2–12 in] DBH). This ecotype
occurs on Braided Fine Active Channel Deposits and Meander Fine Inactive Channel Deposits.
Soils are sandy and moist. This ecotype commonly occurs on river bars where Scour channels-
ridges and Ice-shoved ridges are common microtopographic features. Floristic classes include
Populus balsamifera (pole)/Alnus sp./Platanthera hyperborea.
Riverine Sandy Raspberry-
Rose Low Shrub
This ecotype includes Closed Low Rose Shrub and Open Low Rose Shrub, and occurs on
Braided Inactive Overbank Deposits in the lower Susitna River. Soils are sandy and moist. This
ecotype commonly features abundant dead standing tall Alnus tenuifolia. Alder mortality is
likely related to fungal stem canker disease (Nossov et al. 2011, Ruess et al. 2009). Floristic
classes include Rosa acicularis-Rubus idaeus/Thalictrum sparsiflorum.
Riverine Sandy Spruce Forest This ecotype includes Open White Spruce Forest, and occurs on Braided Inactive Overbank
Deposits and Meander Inactive Overbank Deposits. Soils are sandy and moist. Tree mounds
are common microtopographic features associated with this ecotype. Floristic classes include
Picea glauca/Alnus tenuifolia/Rhytidiadelphus triquetrus.
Riverine Sandy Timber-sized
Balsam Poplar Forest
This ecotype includes Closed Balsam Poplar Forest. Poplar in this ecotype are typically timber-
sized (31–90 cm [12–35 in] DBH). This ecotype occurs on Braided Fine Inactive Channel
Deposits, Braided Active Overbank Deposits, and Meander Active Overbank Deposits. Soils
are sandy with thin interbedded layers of silt. On channel deposits, scour channels-ridges and
ice-shoved ridges are common microtopographic features. Floristic classes include Populus
balsamifera (timber)/Viburnum edule/Pyrola asarifolia.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 52 June 2014
Ecotype Description
Riverine Sandy-Loamy Balsam
Poplar Large Tree Forest
This ecotype includes Balsam Poplar Woodland and Open Balsam Poplar Forest. Poplar in this
ecotype are typically large timber-sized (> 90 cm [35 in] DBH). This ecotype occurs on Meander
Inactive Overbank Deposits and Braided Inactive Overbank Deposits. Soils are sandy and
moist. Tree mounds are common microtopographic features associated with this ecotype.
Floristic classes include Populus balsamifera (large timber)/Alnus tenuifolia/Matteuccia
struthiopteris and Populus balsamifera (large timber)/Oplopanax horridus.
Riverine Sandy-Loamy
Spruce-Balsam Poplar Forest
No plot data was collected in this ecotype in 2012. This ecotype was mapped in the middle
Susitna River on Meander Active Overbank Deposits and Meander Inactive Overbank Deposits.
Riverine Slough A sluggish channel of water, such as a side channel of a river, in which water flows slowly
through low, swampy ground, or a section of an abandoned river channel, e.g., Whisker’s
Slough.
Riverine Wet Sedge-Forb
Marsh
This ecotype includes Subarctic Lowland Herb Bog Meadow, and occurs on margins of beaver
ponds, in abandoned channels, and fens. Floristic classes include Carex utriculata-Equisetum
fluviatile-Potentilla palustris.
Upland Loamy Spruce-Birch
Forest
This ecotype includes Open Spruce-Paper Birch Forest, and occurs on Meander Abandoned
Overbank Deposit and Recent Alluvial Terraces. Soils are loamy and interbedded silt and
organic layers are absent in the upper soil profile. Tree mounds are common microtopographic
features associated with this ecotype. Floristic classes include Picea glauca-Betula
papyrifera/Linnaea borealis.
Upland Poplar No plot data was collected for this ecotype in 2012. This ecotype includes uplands, including
hillsides and lower mountain slopes dominated by poplar forests.
Upland, undifferentiated These include small areas of upland hillsides and mountain slopes directly adjacent to riverine
areas that were not assigned a specific ecotype in the ITU mapping.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 53 June 2014
10. FIGURES
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE
PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 54 June 2014
Figure 3-1. Study Area for the Riparian Vegetation Study, Susitna-Watana Hydroelectric Project, 2013.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 55 June 2014
Figure 4.2-1. Middle Susitna River ELS and ITU Mapping Plot Locations, Riparian Vegetation Study, Susitna-Watana Hydroelectric Project, 2013.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 56 June 2014
Figure 4.2-2. ELS and ITU Mapping Plot Locations in Focus Areas 104 (Whiskers Slough), 115 (Slough 6A), and 128 (Slough 8A), including Sediment Core and Trench Locations, Riparian Vegetation Study, Susitna-Watana Hydroelectric Project, 2013.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 57 June 2014
Figure 4.2-3. ELS and ITU Mapping Plot Locations in the Lower Susitna River, Riparian Vegetation Study, Susitna-Watana Hydroelectric Project,
2013.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 58 June 2014
Figure 4.2-4. ELS Plot Layout, Riparian Vegetation Study, Susitna-Watana Hydroelectric Project,2013.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 59 June 2014
Figure 4.3-1. Integrated Terrain Unit (ITU) Mapping Completed as of Q4 2013, Riparian Vegetation Study, Susitna-Watana Hydroelectric Project, 2013.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 60 June 2014
Figure 4.3-2. Comparison of Two Types of Aerial Imagery Across Three Time Periods, Including Late Spring/Early Summer 2011, Mid-Summer 2011, and Mid-Summer 2012 at Focus Areas 104 (Whiskers Slough) and 128 (Slough 6A), Middle Susitna
River, Riparian Vegetation Study, Susitna-Watana Hydroelectric Project, 2013.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 61 June 2014
Figure 5-1. Maps of Geomorphic Units in Focus Areas 104 (Whiskers Slough), 115 (Slough 6A), and 128 (Slough 8A), Middle Susitna River, Riparian Vegetation Study, Susitna-Watana Hydroelectric Project, 2013.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 62 June 2014
Figure 5-2. Maps of Surface Forms in Focus Areas 104 (Whiskers Slough), 115 (Slough 6A), and 128 (Slough 8A), Middle Susitna River, Riparian Vegetation Study, Susitna-Watana Hydroelectric Project, 2013.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 63 June 2014
Figure 5-3. Maps of Vegetation Classes in Focus Areas 104 (Whiskers Slough), 115 (Slough 6A), and 128 (Slough 8A), Middle Susitna River, Riparian Vegetation Study, Susitna-Watana Hydroelectric Project, 2013.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 64 June 2014
Figure 5-4. Maps of Disturbance in Focus Areas 104 (Whiskers Slough), 115 (Slough 6A), and 128 (Slough 8A), Middle Susitna River, Riparian Vegetation Study, Susitna-Watana Hydroelectric Project, 2013.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 65 June 2014
Figure 5-5. Maps of Poplar Size Classes in Focus Areas 104 (Whiskers Slough), 115 (Slough 6A), and 128 (Slough 6A), Middle Susitna River, Riparian Vegetation Study, Susitna-Watana Hydroelectric Project, 2013.
INITIAL STUDY REPORT RIPARIAN VEGETATION STUDY DOWNSTREAM OF THE PROPOSED SUSITNA-WATANA DAM (11.6)
Susitna-Watana Hydroelectric Project Alaska Energy Authority
FERC Project No. 14241 Part A - Page 66 June 2014
Figure 5-6. Maps of Preliminary Ecotype Classes in Focus Areas 104 (Whiskers Slough), 115 (Slough 6A), and 128 (Slough 8A), Middle Susitna River, Riparian Vegetation Study, Susitna-Watana Hydroelectric Project, 2013.