Loading...
HomeMy WebLinkAboutGeospatial database compiled geologic maping 2015Alaska Resources Library & Information Services Susitna-Watana Hydroelectric Project Document ARLIS Uniform Cover Page Title: SuWa 286 Geospatial database: Compiled geologic mapping in the area of the proposed Susitna-Watana Hydroelectric Project, South-Central Alaska Author(s) – Personal: D.S.P. Stevens, E.N. Bachmann, and T.C. Wright, D.N. Solie Author(s) – Corporate: Alaska Division of Geological & Geophysical Surveys AEA-identified category, if specified: Series: Miscellaneous publication ; 156 Series (ARLIS-assigned report number): Existing numbers on document: Susitna-Watana Hydroelectric Project document number 286 Published by: Date published: Fairbanks, AK : State of Alaska, Department of Natural Resources, Division of Geological & Geophysical Surveys, 2015. Published for: Date or date range of report: Volume and/or Part numbers: Final or Draft status, as indicated: Document type: Pagination: Geodatabase 3 p. (summary) + 2.66 GB of data Related work(s): Pages added/changed by ARLIS: Notes: Not listed on Susitna-Watana documents website. The summary states this geodatabase product is to support the planning of the Susitna-Watana Hydroelectric Project. Only the summary is available online from the ARLIS Document Server. For complete geodatabase content, see the disc. This document is made available by Alaska Resources Library and Information Services (ARLIS) on behalf of Alaska Energy Authority for the Susitna-Watana Hydroelectric Project. All reports in the Susitna-Watana Hydroelectric Project Document series include an ARLIS- produced cover page and an ARLIS-assigned number for uniformity and citability. All reports are posted online at http://www.arlis.org/resources/susitna-watana/ Miscellaneous Publication 156 GEOSPATIAL DATABASE: Compiled Geologic Mapping in the Area of the Proposed Susitna–Watana Hydroelectric Project, South-central Alaska Mapping compiled by: D.S.P. Stevens, E.N. Bachmann, and T.C. Wright Bedrock compilation review and revision by: D.N. Solie, Baseline Geoconsulting, LLC Published by STATE OF ALASKA DEPARTMENT OF NATURAL RESOURCES DIVISION OF GEOLOGICAL & GEOPHYSICAL SURVEYS 3354 College Road, Fairbanks, AK 99709-3707  907-451-5020 www.dggs.alaska.gov  dggspubs@alaska.gov 2015 GEOSPATIAL DATABASE: Compiled Geologic Mapping in the Area of the Proposed Susitna–Watana Hydroelectric Project, South-central Alaska Mapping compiled by: D.S.P. Stevens, E.N. Bachmann, and T.C. Wright Bedrock compilation review and revision by: D.N. Solie, Baseline Geoconsulting, LLC PROJECT SUMMARY The Alaska Energy Authority (AEA) in 2010 was authorized by the State of Alaska to begin laying the groundwork to develop the Susitna–Watana Hydroelectric Project on the Susitna River, Alaska. The project was intended to help meet the future electrical needs of Alaska’s Railbelt Region by providing clean, renewable energy at the lowest possible long-term cost. An accurate assessment of the site geology is important for dam location, design, and construction, as well as for other planning and land management decisions in the region. In support of the proposed Susitna–Watana Hydroelectric Project, the Alaska Division of Geological & Geophysical Surveys (DGGS) developed a Geographic Information System (GIS)-based geologic compilation of published and unpublished maps for twelve, inch-to-mile (1:63,360-scale) quadrangles (fig. 1) encompassing the proposed hydroelectric project footprint, including the anticipated reservoir and surrounding area. DGGS geologists reviewed and analyzed existing geologic mapping for quality and completeness, and the maps were converted for use in GIS (table 1). The conversion process included scanning and georeferencing the original hard-copy map documents, creating a geodatabase, digitizing the geologic data, assigning attributes, and producing a digital data product for public release. The best available geologic mapping was synthesized into a single compilation data layer, and is packaged along with georeferenced scans and digitized vector files of the original geologic source maps. Bedrock geology was reviewed and revised by an independent contractor to ensure consistency with current geologic interpretations of the area. This geodatabase product will be a valuable reference resource for developers, planners, and scientists working on the hydroelectric project, as well as for any other projects in the area. ACKNOWLEDGMENTS This capital project was funded by the Alaska Energy Authority (AEA) through the Alaska Department of Commerce, Community, and Economic Development (DCCED). MP 156 Page 1 Table 1. Data Sources for Geologic Map Compilation, Proposed Susitna–Watana Hydroelectric Project DAS01 Kline, J.T., Bundtzen, T.K., and Smith, T.E., 1990, Preliminary bedrock geologic map of the Talkeetna Mountains D-2 Quadrangle, Alaska: Alaska Division of Geological & Geophysical Surveys Public Data File 90-24, 13 p., 1 sheet, scale 1:63,360. doi:10.14509/1458 DAS02 Smith, T.E., Albanese, M.D., and Kline, G.L., 1988, Geologic map of the Healy A-2 Quadrangle, Alaska: Alaska Division of Geological & Geophysical Surveys Professional Report 95, 1 sheet, scale 1:63,360. doi:10.14509/2276 DAS03 Csejtey, Béla, Jr., Nelson, W.H., Jones, D.L., Silberling, N.J., Dean, R.M., Morris, M.S., Lanphere, M.A., Smith, J.G., and Silberman, M.L., 1978, Reconnaissance geologic map and geochronology, Talkeetna Mountains Quadrangle, northern part of Anchorage Quadrangle, and southwest corner of Healy Quadrangle, Alaska: U.S. Geological Survey Open-File Report 78-558-A, 60 p., 1 sheet, scale 1:250,000. http://dggs.alaska.gov/pubs/id/12425 DAS04 Reger, R.D., Bundtzen, T.K., and Smith, T.E., 1990, Geology of the Healy A-3 Quadrangle, Alaska: Alaska Division of Geological & Geophysical Surveys Public Data File 90-1, 13 p., 2 sheets, scale 1:63,360. doi:10.14509/1433 DAS05 Clautice, K.H., 1990, Geologic map of the Valdez Creek mining district: Alaska Division of Geological & Geophysical Surveys Public Data File 90-30, 1 sheet, scale 1:250,000. doi:10.14509/1464 DAS06– DAS21 Acres, 1982a, Susitna Hydroelectric Project: 1980–81 Geotechnical Report, v. 2, part 2, Appendix G–K, final draft, 237 p. http://www.arlis.org/docs/vol1/Susitna/0/APA69.html DAS22 Woodward-Clyde Consultants, 1982, Final report on seismic studies for Susitna Hydroelectric Project, 363 p. (fig. 3–4). http://www.arlis.org/docs/vol1/Susitna/12/APA1255.pdf DAS23 Woodward-Clyde Consultants, 1982, Final report on seismic studies for Susitna Hydroelectric Project, 363 p. (fig. 4–15). http://www.arlis.org/docs/vol1/Susitna/12/APA1255.pdf DAS24 Merritt, R.D., Eakins, G.R., and Clough, J.G., 1982, Coal investigation of the Susitna Lowland: Alaska Division of Geological & Geophysical Surveys Alaska Open-File Report 142, 89 p., 4 sheets, scale 1:250,000. doi:10.14509/62 DAS25 Eakins, G.R., Jones, B.K., and Forbes, R.B., 1977, Investigation of Alaska’s uranium potential: Alaska Division of Geological & Geophysical Surveys Alaska Open-File Report 109, 213 p., 10 sheets, scale 1:250,000. doi:10.14509/21 DAS26 Csejtey, Béla, Jr., 1974, Reconnaissance geologic investigations in the Talkeetna Mountains, Alaska: U.S. Geological Survey Open-File Report 74-147, 48 p., 1 sheet, scale 1:63,360. http://dggs.alaska.gov/pubs/id/11004 DAS27– DAS28 Acres, 1982b, Susitna Hydroelectric Project, 1982 Supplement to 1980–81 Geotechnical Report. http://www.arlis.org/docs/vol1/Susitna/0/APA68.html DAS29 Richter, D.H., 1963, Geology of the Portage Creek–Susitna River area: Alaska Division of Mines and Minerals Geologic Report 3, 2 sheets, scale 1:24,000. doi:10.14509/332 DAS30 Woodward-Clyde Consultants, 1982, Final report on seismic studies for Susitna Hydroelectric Project, 363 p. (fig. 4–21). http://www.arlis.org/docs/vol1/Susitna/12/APA1255.pdf DAS31 Csejtey, Béla, Jr., Mullen, M.W., Cox, D.P., and Stricker, G.D., 1992, Geology and geochronology of the Healy Quadrangle, south-central Alaska: U.S. Geological Survey Miscellaneous Investigations Series Map 1961, 63 p., 2 sheets, scale 1:250,000. http://dggs.alaska.gov/pubs/id/12847 DAS33 Clautice, K.H., Newberry, R.J., Pinney, D.S., Blodgett, R.B., Bundtzen, T.K., Gage, B.G., Harris, E.E., Liss, S.A., Miller, M.L., Reifenstuhl, R.R., and Clough, J.G., 2001, Geologic map of the Chulitna region, southcentral Alaska: Alaska Division of Geological & Geophysical Surveys Report of Investigation 2001- 1B, 32 p., 1 sheet, scale 1:63,360. doi:10.14509/2771 DAS34 Woodward-Clyde Consultants, 1982, Final report on seismic studies for Susitna Hydroelectric Project, 363 p. (fig. 4–17). http://www.arlis.org/docs/vol1/Susitna/12/APA1255.pdf MP 156 Page 2 Figure 1. Map showing 1:63,360-scale quadrangles included in the geologic map compilation geodatabase: Healy A-2, A-3, A-4, A-5; and Talkeetna Mountains C-2, C-3, C-4, C-5, D-2, D-3, D-4, D-5. Red dot is location of the proposed dam and powerhouse. MP 156 Page 3