Loading...
HomeMy WebLinkAboutSusitna FERC Vol 3 exhibit F 1983SUSITNA HYDROELECTRIC PROJECT FERC LICENSE APPLICATION PROJECT NO . 7114-000 As accepted by FERC , July. 27, 1983 .BEFORE THE FEDERAL ENERGY REGULATORY COMMISSION APPLICATION FOR LICENSE FOR MAJOR PROJECT SUSITNA HYDROELECTRIC PROJECT VOLUME 3 EXHIBIT F FEBRUARY 1983 Prepared by: • .___ ___________ ALASKA POWER AUTHORITY ___________ ____. ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT PLATE INDEX PLATE NO. FI F2 F3 F4 F5 F6 F7 F8 F9 FlO FII FI2 FI3 FI4 FI5 FI6 FI7 FI8 FI9 F20 F21 F22 F23 F24 F25 F26 F27 F28 F29 F30 F31 F32 F33 F34 F35 F36 F37 F38 WATANA TITLE RAILBELT AREA RESERVOIR PLAN SITE LAYOUT GENERAL ARRANGEMENT MAIN DAM -PLAN MAIN DAM -SECTION MAIN DAM -PROFILE e.DETAIL MAIN DAM -GROUTING a DRAINAGE DIVERSION -GENERAL ARRANGEMENT DIVERSION -SECTIONS D IVERS ION -INTAKE STRUCTURES MAIN SPILLWAY -GENERAL ARRANGEMENT MAIN SPILLWAY -CONTROL STRUCTURE MAIN SPILLWAY - CHUTE SECTIONS MAIN SPILLWAY -FLIP BUCKET OUTLET FACILITIES -GENERAL ARRANGEMENT OUTLET FACILITIES - GATE STRUCTURE EMERGENCY SPILLWAY EMERGENCY RELEASE -SECTIONS DOWNSTREAM PORTALS -PLAN a SECTIONS POWER FACILITIES -GENERAL ARRANGEMENT POWER FACILITIES -ACCESS POWER FACILITIES -PLAN a SECTIONS POWER INTAKE -SECTIONS POWERHOUSE -PLANS POWERHOUSE -SECTIONS TRANSFORMER GALLERY -PLAN a SECTIONS SURGE CHAMBER e.TAILRACE -SECTIONS ELECTRICAL LEGEND POWERHOUSE -SINGLE LINE DIAGRAM SWITCHYARD - SI NGLE LINE DIAGRAM e.PLAN ACCESS PLAN - PROPOSED ROUTE ACCESS PLAN - PROPOSED ROUTE TYPICAL DETAILS GENERAL LAYOUT -SITE FACILITIES GENERAL LAYOUT -CONSTRUCTION e.HAUL ROADS MAIN CONSTRUCTION CAMP SITE VILLAGE AND TOWN SITE WATANA a DEVIL CANYON -CONSTRUCTION CAMP DETAILS PLATE NO. F39 F40 F41 F42 F43 F44 F45 F46 F47 F48 F49 F50 F51 F52 F53 F54 F55 F56 F57 F58 F59 F60 F61 F62 F63 F64 F65 F66 F67 F68 F69 F70 F71 F72 F73 DEVI L CANYON TITLE RESERVOIR PLAN SITE LAYOUT GENERAL ARRANGEMENT DAMS -PLAN e.PROFILE MAIN DAM -GEOMETRY MAIN DAM - CROWN SECTION MAIN DAM -SECTIONS MAl N DA M -THRUST BLOCKS MAIN DAM -GROUTING a DRAINAGE MAIN DAM -OUTLET FACILITIES SADDLE DAM -SECTION SADDLE DAM-PROFILE a.DETAIL DIVERSION -GENERAL ARRANGEMENT DIVERSION -COFFERDAM SECTIONS DIVERSION -SECTIONS MAIN SPILLWAY -GENERAL ARRANGEMENT MAIN SPILLWAY - CONTROL STRUCTURE MAIN SPILLWAY -CHUTE SECTIONS EMERGENCY SPILLWAY -GENERAL ARRANGEMENT EMERGENCY SPILLWAY -SECTiONS POWER FACILITIES -GENERAL ARRANGEMENT POWER FACI LI TI ES -ACCESS POWER FACILITIES -PLAN a.SECTIONS POWER INTAKE -SECTIONS POWERHOUSE -PLANS POWERHOUSE -SECTIONS TRANSFORMER GALLERY -PLAN a.SECTIONS SURGE CHAMBER a.TAILRACE -SECTIONS TAILRACE PORTAL -PLAN a.SE.CTIONS POWERHOUSE -SINGLE LINE DIAGRAM SWITCHYARD -SINGLE LINE DIAGRAM a.PLAN GENERAL LAYOUT -SITE FACILITIES GENERAL LAYOUT -CONSTRUCTION a HAUL ROADS MAIN CONSTRUCTION CAMP SITE TEMPORARY VILLAGE PLATE NO. F74 F75 F76 F77 F78 F79 F80 F81 TRANSMISSION TITLE RAILBELT 345 KV SINGLE LINE DIAGRAM ESTER SUBSTATION - SINGLE UNE DIAGRAM a PLAN GOLD CREEK - SINGLE LINE DIAGRAM a PLAN WILLOW SUBSTATION -SINGLE LINE DIAGRAM a PLAN KNIK ARM SUBSTATION -SINGLE LINE DIAGRAM a PLAN UNI VERSITY SUBSTATION - SINGLE LINE DIAGRAM a PLAN TYPICAL TRANSMISSION LINE STRUCTURES 345 KV SYSTEM SINGLE DIAGRAM a TRANSMISSION CORRIDOR PLATE F I SUSITNA POWER AUTHORITY ALASKA HYDROELECTRIC PROJECT 20 EXHIBIT F RAILBELT AREA 4,0 MILES ( I INCH'20 MILES)SCALE O~i~~~~iiiiii_ LEGEND UNDIVIDED HIGHWAY-J3'--PRIMARY PAVED IVIDED HIGHWAY-..:v--SECONDARY PAVED UNO SECONDARY GRAVEL HIGHWAY ~RAILROAD _000-RIVER KEY MAP / / "o '" .../ 600N CH - I MILE)(I IN - 2 MILES i 8 MILESo4! SCALE:i _4 MILES)(I INCH - --- LEGEND AL MAXIMUM ---NORM"rING LEVEL---..----OPER~I EL. 2185 CONTOURS AR~d~~2300---FEET A80VE \ LOCATION MAP oi 4 T MILES (liNCH ·4MILES) AREA-E ~~J~~Ea AGGREGATE SCALE -~-~J 2-345 KV TRANSMISSION LINES TO GOLDCREEK WATANA DAM '/..,,:>00 0 1000 2000 FEET SCALE i !( I INCH =1000 FEET) [i] ! ALASKA POWER AUTHORITY I I SUSITNA HYDROELECTRIC PROJECT I I WATANA I • I - -----l--- I SITE LAYOUT I I EXHIBIT F I PLATE F3 01o .~I 01 ~I r!:j "'I I I 8j ~; .,.1..., wi 01 ~~~1 ~~§! ! ..."'~§I "':1 :el ffil I ... I "'I ",I I I I N 3.228,000 N3 N 3.226.000 N3 30 N 3 32000 -lil 34 PLATE F4 ( I INCH =200 FEET) ,.~ ~~~IOO "--_-----ZIl)O 200 WATANA GENERAL ARRANGEMENT ,~ SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY EXHIBIT F i \ o 400 FEETSCALE~i~~OiJ;;iiiooo_1iIi \10 0 \'Of:J'o ",...... \'000 ", --I------~~ ", ACCESS ACCESS ROAD 2-345 KV TtlANSMfSSION LI NES TO GOLD CREEK !-----I-------.-_ .-----I - ! ! SWITCHYARD !EU240f EMERGENCY -1-----, SPILLWAY eo 'fi.... LU ~-,~", ..',---r:3'V-... '\/((~/,/ I / i <>\~ ~~'" ..' OO~'1-\ \: I / // ( ~ l / UPSTREAM ,COFFERDAM ,I' N ll,226,ooo -'--+---;7--='~+_---___=,.L~--____c7""'-:::.-__+H-+---------\---\-\-----I- PLATE F5 WATANA MAIN DAM PLAN .: / ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT 200 EXHIBIT F o 400 FEET SCALE ~i""""""""",,~~iiiiii_!(I INCH =200 FEET) .>:':.r »>: ~/// -/~--+---+--~I-~ <iP ------// oo 0, '"<tt- W/[ I 1 I )1 1 I II -I I: II 1 I Ii II II 1 I// SURGE CHAMBER PARKINGAREA POWERHOUSE CONTROL BUILDING TRANSFORMER GALLERY 8 Q <te-t- W N 3,225,000 "'----1 ..---..---..----1 FINE FILTER COARSE FILTER CHANGE OF SLOPE EL.2110 ~GRAVEL FILL~ CORE .--_..--._----------+--------------------------1 FINE FILTER COARSE FILTER ._-.__._._--!--+--!------+------\---\---~---------+---I ~PROCESSEO .i-:" /GRAVEL FILL NORMAL MAXIMUM OPERATING LEVEL EL.2185 ----.------..---.----------.I---JL-/------+---+-+--\--------------+--l ----·---..----------------I----I--+------f---~~~t----------t~ liS ~ ..-L~OP OF R~_C_K__," ---------------...----..-----..__. --------.------_..._-_..._-------.,....-;...--=--- -------_......_--_._--------_. .~....s...--:------------------------------------------+----f--/-------+-----\--\---\--------------+_--I ...--.----..--.---.....---------.-----.---..----.--------~~~----------.------+_+____+_-+----'f--Jrl~---------------"",.,.---_1 ----_.__.._-- 2 "JI UPSTREAM COFFERDAM (FOR DETAILS SEE PLATE FlO) APPROXIMATE TOPOF SOUNDROCK --..--..--·,·--..--.."""=~~~iiiF=====:::.:.:.:==========..::======~~~:::::==========; --------'====:.-==j=-~=!=-.=:!=~~~r====~~=~~~----'-_j ~--------------_...._---- 2400 2300 2200 2100 2000 ....1900'"'"lL ~ z 18000 fi>''"..J '"1700 1600 1!l00 1400 1300 1200 PARTIAL SECTION THROUGH MAIN DAM AT MAXIMUM HEIGHT WATANA MAIN DAM SECTION SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY o 100 200 FEET SCALE 1"1~~""'111===:J___(I INCH =100 FEET) .--------I ~ I DOWNSTREAM COFFERDAM (TO BE PARTLY REMOVED AFTER CONSTRUCTION FORDETAILS SEE PLA_T..:.E_F_IO..:.)--!\--__.--I I I COARSE FILTER COARSE FILTER 2 i Ir:;::;'.I~~P~~ROC-K---··· ,.---..----..---.,---'---....-__..__::::';;:;~_-".L-_...L._'.=--J14001--+-------------<"'-------- 1300 L-_ 1800 I--+---..:---..~----- 1900,---------------- 2'=ll ....1700 1--+--------------'........c--: ~ i!: ~1600 1=~'"..J '"1!l00 r-I--------------------:;:;=:===~;;JI~~ EXHIBIT F PLATE F6 PARTIAL SECTION THROUGH MAIN DAM AT MAXIMUM HEIGHT SLOPE1100' CREST EL. 2210 ORIGINAL GROUND SURFACE TOP OF ROCK LOPEMAIN SPILLWAY CONTROL STRUCTURE------ 1600 r----------------------------~""'-~.;.<~,.~~~~VA~IOF~L~~~-~~---__"_r'~L----------~-------~-.-------------~~________I 2400 I-----~__~~__~__~~_~~__~~__~~~~__~__ 1400 r-~~~~~~~~~~-------------------~..::::::"""""'~~~'_='::;;;_S~~----~----~--~------------.---------------J I- W~2000 r--------------=:""-~~':::::_:::::._---------+-------~-~~-~~~~-+_~-~-~~-~___=~~~~~-~=--~~~~~~-~-~--~-----1 ~ zo~IBOO 1---~~~~--~~~~~~~~~-~~-~-3'.Q;~2~,,~_j;,.e:-!l!!!!i!."!Bh-JW~!'i!L~E!E"g--~~-~-+__T~~~~~~~~-~--~-~~~-----------------_1 :;I w ...J W 1200 PROFILE (LOOKING UPSTREAM) SCALE A AXIS OF DAM EL.2205 NOMINALCRESTELEVATION-to in PROFILE SHOWING CREST ELEVATIONS NT.S. MAIN SPILLWAY CONTROL STRUCTURE OVERBUILD FOR SEISMIC \TTLEMENT EL.2170 3'ROAD BASE 10.0' 5.0' //SLOPE VARIES ---::i~~;;fl~~d2;~~~E~L::.~2~21~0==:=1===~~~4--;:-5' OVERBUILD FOR SEISMIC SETTLEMENT" NOMINAL----, PROFILE OF DAM FILTER FABRIC- RIP RAP .ORMAL MAXIMUM OPERATING LEVEL EL. 2185 """"""0--------0----:'1 PROCESSED/ """""--------"/GRAVEL2.3 I FILL DETAIL I (PLATEF6) SCALE B o 20 40 FEET SCALE B~I"~~~iiiiiiliiiiii~!(liNCH.20 FEET) o 200 400 FEET SCALE A j !(liNCH.200 FEET) SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY.1---,-----,------------------1 WATANA MAIN DAM PROFILE AND DETAIL EXHIBIT F PLATE F7 EMERGENCY SPILLWAY "8 HOLES PLATE Fa DRAINAGE HOl [ 2400 2000 2200 'r--"""" ~~-"--CONCRETE SLAB DRAINAGE CHANNEL SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY WATANA MAIN DAM GROUTING a DRAINAGE EXHIBIT F DETAIL -GROUTING a DRAINAGE GALLERY SCALE D ··--·-------·--------11600 0 5 10 FE'ET SCALE 0 I I ( I INCH= 5 FEET ) 0 10 20 FEET SCALE C I !( IINCH= 10FEET) 0 100 200 FEET SCALE 8 ; !( liNCH =100FEET) 0 200 400 FEET SCALE A I !( I INCH=200 FEET) 2-ROW GROUT CURTAIN Q GROUTING AND DRAINAGE GALLERY __________________________J 1400 p ,PRIMARY GROUTHOLES So SECONDARY " To TERTIARY Q 0 QUATERNARY ,-'- _,.-,_,.-,-,.-\-'_v- I SLOPE-. ORIGINAL GROUN SURFACE 20.0' GROUT HOLE SPACING SCALE C 40.0' DAM CREST EL. 2210 VENT SHAFT "'---++--DRAINAGE HOLES I+I --SURGE CHAMBER I 5.0'5.0' t UPSTREAM P ROW ~DOWNSTREAM S ROW 10.0' 10.0' LONGITUDINAL SECTION (LOOKING UPSTREAM) SCALE A 20.0' ACCESS SHAFT II II II II II II II .~---LL~~~~~fGE TRANSFORMER GALLERY APPROX. EL.2210 PERMANENT ACCESS SHAFT CA8LE SHAFT DRAINAGE GALLERY 'So' ZONE OF CONSOLIDATION GROUTING (APP 30 FT.DEEP) GROUTING /DRAINAGE GALLERY .-.---DRAINAGE HOLES EXTENSION OF DAM- GROUT CURTAIN --------t\-\-+-----I+---+-i---1 SECTION A-A SCALE A ,,---__GROUT '--_'\-_-~CURTAIN I...OUTLET FACILITIES TUNNEL SPILLWAY CONTROL STRUCTURE--- 1 "8 GROUT CURTAIN -----<--III NORMAL MAXIMUM OPERATING LEVEL EL.2185 APPROXIMATE GROUND \SURFACE-----_.---------- _____--F'-I-'-I-I-,-'-'-'-. GDRROAUINTAINGEG AND j =r=======::b=f;;;,.,!L.-..-GALLERY IN SPILLWAY._~--ST~CTURE 50'DEEP GALLERY ---------- GROUT ZONE POWER INTAKE t--------.--------------'~<c---------------.-------'c--+-t-'<- 2400 2200 .--/ I-ww 2000u, ~ z 0 ~1800 w ..Jw 1600 1400 NORMAL MAXIMUM 2200 OPERATING 2100 MINIMUM OPERATING W.L EL.2060 ~ EL2025 EL.203Q 2000 I-.1900 wwu, ~ z 1800 Q I-~ "'iiJ 1700 1600 1500 1400 SECTION 8-8 SCALE B ,DIVERSION INTAKES - o MAINDAMAXIS --[ACCESS T NNEL DOWNSTREAM PLUG___..~-=-::.~::~____35+00 PLAN SCALE A TAILRACE TUNNEL PLUG (TO BE CONSTRUCTED AFTER DIVERSION) 1750~ 1700 .s-> CRES;··________. EL. 1472 _______ DOWNSTREAM COFFERDAM 1300r----t----------------+----------------1 I-+----------------+-------------------j -.. -,I,""""""""'., LEL.1450 "-FLIP BUCKET--..__ (TO BE CONSTRUCTED AFTER DIVERSION) ~'"r~~~V~tL (OUTLET PORTAL________"",~FACE FOR DETAILS SEE PLATE F20 --------\-EL.156t:/iUIDEWALL_____----38''Dllil-C-O-NC - - - ----_~/ROCK TO BE EXCAVATED AFTERJLINEDTUNNELI-,f :.~/CONSTRUCTION OF ilVERSION TUNNEL '~:l /J;J""~NOR,MAL TAIL WATER_<1['::'"/EL.1455 4cs u,o , 1"120'--i 100'1---'tOW~n~EAMd~o'~I (TO BE CONSTRUCTED AFTER DIVERSION) x <I: /'FOR DETAILS SEE PLATE FI9'-\(ACCESS TUNNEL ~--,'..J I~I 160'I 1111="1\~340'11,=", f--'20 0JJ I'UP~UJ";;AM'EXPANSION CHAMBER (TO BE CONSTRUCTED AFTER DIVERSION) ~~R I G I NA L GROUND------______SURFACE MAIN DAM -------I--- SLOPE 0.99% lEI 38 DJA.CONC.~II LINED TUNNEL )==7l il ~FOR DETAILS .»/!/it /SEE PLATE FII ORIGINAL / GROUND ,/ SURFACE~ 1 I' EL. 1545 EL.1490 EL.1485 TRASHRACKS FOR \LOW LEVEL OUTLETS //~YAY/~~TEMP~::R~PLATFORM ~~:~G CONSTRUCTION OF TUNNEL ~ MAX. W.L. 1536 W FLOW--...-- -1-'._---- 2000 1900 1800 I-1700UJ UJu, z z \600 0 t>UJ ..J 1500UJ 100 200 45+00 o 200 FEET SCALE B ~I~~~~iiiiii~1 (lINCH =100 FEET) o 400 FEET SCALE A I '(lINCH =200 FEET) 40+0020+00 STATIONING IN FEET PROFILE TUNNEL SCALE B 15+000+005+00 ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT WATANA DIVERSION GENERAL ARRANGEMENT EXHIBIT F PLATE F9 i.DAM NORMAL TAILWATER EL.1455 --.,_.._---- ~3S' DIA.CONC.LINED TUNNEL SLOPE 0.36%~ /ORIGINAL GROUND SURFACE ~'Zf----------------~------__+_----__I ----------,~ ---. ).----==== .£l ~"'--ROCK SURFACE GROUND SURFACE" .> j I ORIGINAL MAX.w.L.EL.1536 TEMPORARY /IJ 4PLATFORM/II rr:OUTLET PORTAL DURING CONSTRUCTION"/'4OF TUNNEL \1!i rBEDROCK SURFACE \ EL.1545 ./j!t I 100y':CONCRETE PLUG Il;..~T1,(ROCK TO BE EXCAVATED AFTER \ /'I'='''/"INTAKE STRUCTURE I 60'i 60'(ATFOTSEER CCOOMNMSTISRSUIOCNTIENDG 4L -,<,CONSTRUCTION OF DIVERSION TUNNEL /'·.lID~/(FOR DETAILS SEE PLATEFill I EL.1500""<; EL.l4S5 ,'''==~/~=.,-..l1J!4''!I1"'-""l!!.'!l1L1 ---1 1---------c---------+---I--,--II----J.rL4-EM~~~~~Y RELEASE --------------+--'--=--I.~"""II1\'~~::::00-:::"'<:-"--~"="h.1----+--..=""----.0.-;;-;;;7-;=--------1,'~7,!II t~~;~~~~~~~~~~~~~~~~~~~/~~:F~:,C~:.;},k:IT:,:I\i~-S:)::d '?o\,..----/=-.,...:.-;;"j.~L.I420 ~.-I I:+::1---------...lllI!i=!W"-----f---..lIilEL.1405 I ·r::-_~__.----+--==~----,'!F ~)\""""S'~II\"'IJI,~======__;>~l'I:==-::f===%C~"<,~\f-EL.1410 ----"''--=-----------------1 /'\...ROCK..E XCAVATED AFTER COMPL TION OF INTAKE STRUC URE 2000 1900 ISOO f-1700 UJ UJ U. ~ z 16000 1=~'Ll-'UJ 1500 1400 1300 1----------------4---------------....j 50.0045.0040.0020.0015+000+00 1200 I-.----....L -l l-L-....J I-...L ---IL-----l -5.00 25.00 STATION IN FEET PROFILE -TUNNEL 2 SCALE A 1600,-------------------------------------------, IS" DIA. CORRUGATED PERFORATED DRAIN TYPICAL TUNNEL CROSS SECTION SCREENED GRAVEL AROUND DRAIN 45'-0"DIA TUNNEL I 3S'-0"DIA. TUNNEL 2 51'-0" DIA. TUNNEL I 44',0"DIA TUNNEL 2 IS" DIA. CORRUGATED PERFORATED DRAIN CROSS SECTION AT PLUG (TYPICAL) N.T.S CONTACT GROUTING~ THROUGH TUNNEL DRAINAGE HOLE I, ,[I 4 7~0"DIA. TUNNEL I 40'-0"DIA TUNNEL 2 EXCAVATION FOR MAIN DAM DEWATERING SYSTEM AS REQUIRED WATANA UPSTREAM COFFERDAM SCALE B MAXIMUM DEPTH APPROX. 100 1560 f--------------------i--=----=+----------------- MAX. f-WLI536 ~~~1520 f-__-"''''''-'ll'--'''t1Bl=...L!!..b=''''_''7'4L'''-clf:F''-llh,.L:::....;:s...~-----_/_.~0~R~IG~I~N~A=-L~G"R'.'''0UNO_S_UR_F_A_C_E -j zo !;ii;;14S0 ~--­ ...J UJ N.T.S 1520 I-----------------------------------------~ WATANA DOWNSTREAM COFFERDAM SCALE B PLATE FlO 20 FEET,( I INCH =10 FEET) SO FEET ;( I INCH =40 FEET) 200 FEET ( I INCH =100 FEET) WATANA DIVERSION SECTIONS 10 100 40 EXHIBIT F SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY o SCALE C ~j1iIIII1iIIII~;'ioiiiiii";'] o SCALE S ~;IiIIIIIiIIII......ioiiiiiiioiiiiiiiiiiiil o SCII.LE A ~;""",,,,,,,,II'5~ioiiiiii~ ".,1'GROUTING AND DRAINAGE HOLES',___I " SECTION ALONG ~OF TUNNEL AT PLUG LOCATION SCALE C " " i .. ",,,,,=,,,,="u " -N ..J..J WUJ 1.01 19.0'ZZzz -:::>:::> f-f-- <i<i FLOWDO-----'.,-", --.f1.0'<t '" 1 \7'III\!"~: MAXIMUM DEPTH APPROX. 100' EL.1440 ..111t\"t';Iiig?.. 50' I '\:-ALLUVIUM ~ I DEWATERING SYSTEM I AS REQUIRED I ;l\' CLOSURE DAM BERM AS REQUIRED TOP OF ROCK 1800 1725 1775 1700 1750 PLATE F II ~---1675 \6'/.0 ~1650 ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT WATANA DIVERSION INTAKE STRUCTURES EXHIBIT F VENT PIPE ,I ~POST TENSIONED'ANCHORS I a CONSOLID-ATIONGROUT HOLES .~ WALLS AND INVERT SECTION S-S SCALE A + + o --+is!+--+-:.,-~--------,.v"'--~l- '" o 4D 80 FEET SCALE 8 ~I1IIII1IIII"';';:i;,;.=a_~·(j INCH=40 FEET) o 16 32 FEET SCALE A I (1/16 INCH= I FEET) EI•. 1545 ...--..J....,+.......::.L.,..,.,.'------..I FLOW- " LOCATION PLAN SCALE 8 /....... iNRS~~~~~g'-"K"';=FT~E=:R:---,. ~W~U~~~OG~~g~I.CONSOLIDATION GROUTHOLES RELEASE FACILITIES :-1 TTil I PVC PIPE SLEEVES FOR PRESSURE I I I I I RELIEF HOLES EL.1528 '~,iltf-1~~~-0!!!l!~~~~§===~~~3=::=~1--~I :I III END OF PIER i+rtr:1111:~ITII PVC PIPE SLEEVES FOR EL.l49~O~1~1~'~~::~~[~::~~::I:::~~~~=::m~~PRESSURE RELIEF HOLES 7 TENSIONED ANCHORS AI~­ I---CONSOLIDATIONhhr------f----.J1__GROUT HOLE SECTION A-A SCALE A PRESSURE RELIEF IN WALLS AND INVERT I AND INVERT SLEEVES FOR CONSOLIDATION GROUTING AND EL. 1458 GATE HOIST SEALING FACE FLOW ~­CLOSURE GATE ---itt-H--*L~ EL.1545 't INTAKE I I I I I I I II "II II r~ I /EL.1420 /I I I I I I I I I I I ~INTAKEI(TUNNEL NO.2) I I I 1----lll-----Hkf.---::::,j/ I I I I I I r-----III-----Hkf.-----:~ I : I ---~II----+I4----~ "I II i EL.1414 ~L ...! 10 \i I I EL.1420 AII'RIIIi=AII PLAN AT EL.1545 SCALE A EXTENSION GATE GUIDE II II IIrl I I }----it,~INTAKE I I I I III I I I I , I I I I I I I I S.,a ELEVATION SCALE A 'I "S'",Ji I I I I I I I, I I IH'4V ==~J -1' -t<?<?,> I\>IV~I\>'000 LOOSE MATERIALTO BE REMOVED IN THIS AREA ~/<. e-<~ TAILRACE TUNNEL \... SCHARGE STRUCTURE FLIP ~~~Kg~.;'AN_IEsDI~EE.!~A.T:.-E:..:..FI",5_~~1 CONCRETE FACING ORIGINAL GROUND(SOUTH SIDE)!?I''L~~~~~~~~~~~~~~__~ . ASSUMED TOP OF ROCK(SOUTH SJDE) I I t B BOX DRAINS (TYPICAL) //7AERATION GALLERY <TYP) OUTLET FACILITIES TUNNEL 30.0' DRAINAGE HOLES TO DRAINAGE GALLERY '.~--FLO'"ORIGINAL GROUND (NORTH SIDE)-~..----------...~SIDE) ••~.-ASSUMED TOP OF ROCK (NORiH"~"~-'-.:;:;;;;:;'~"::::::::::l,,~""-".~~_I ..-~,,~::-=::::::.: I \ -,,-,I ~-,,J ....zw:=;....::>m -; -~ ~<C I ~ I ....i "U) ll!u ,~ C0..0 N N ..iw ---- DRAINA~ . GALLERY DRAINAGE HOLES o-EL.:i2o'r--_ ......E 2148 _--------r--__-...:~ ----------------------------------------- r--- \\_-- 2000 100 200 FEETO~~~~__.'(liNCH =100 FEET)SCALE ~ 20+0015+00 PROFILE STATIONING IN FEET 10+005+000+00 ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT WATANA MAIN SPILLWAY GENERAL ARRANGEMENT EXHIBIT F PLATE FI2 --~ :f?IifC1' il) --~ =I "CJn ~n' il\ i ---1--.- 1/\ II 1\,"CONTROL I I STRUCTURE II \~ROLLWAY I / \ I .t !/'\I /---• /1\/~V-..--I lROLLWAY I GATE 1--"-- EL.2207 \ .J I II-__+_-"-~~ff"IIIII I t---:"'--~I I1----+----4 1 ~. EL,2195 I I I _I 1 ~I ·t »: -:~d"'--'Mi'-O'36~0'r 16 ,_0'""I i"I I I I I ...--".I:II I';I .'~-11 I I ~I~!I:I :1_"'--1 III'I ACCESS "\1 I 1 -GATE II,I SHAFT ,1 I ----"!I I,] I I I __..'»>I::: .---+-}.Lt=--:~::::'::'~~1f I J ...»>::I ~L---~T1'OII"rn"~'III"Ii:I ~~----------~--« l,~~~-.'n-~ \~h-!.~1":;':-r --I -.,....,'di~_---i1-.::------~--------------------.i---.J : r _--..t::'------i-------------------t----...J\-~TO FOUNDATION 1 GROUTING AND I ' ORAINAGE ,IGAllERIES18-0"~2'-O'52'·o'IB'·O· DAM IMPERVIOUS CORE MATERIAL , ~Q. l A FACTORS OF SAFETY F~~~FLOATATION OV£RTURNIHGSLIDINGFOUNDATION STRESS u.s/as IPSI) WAUNA DAM SPILLWAY CONTROL STRUCTURE SUMMARY OF STABILITY ANALYSES LOAIl lXlOIOITlOM NORMAL IHC~21152 5,5 N.A.5.S 4.3 2.5LOAOS UNUSUAL OR.liN PLUGG£D 19/42 1,7 H.A.4,8 2,5 II EXTREfol( FACE EARTHQlW(E -291101 30,4 N,"'.1.5 ".:1,4 10,8 SUI f'HY$tCAl.PARAMETERS.p.4" c e 30 PSI GATE I+OI5T SECTION B-B ,..c STOPlOG GUIDES -'0 NORMAL MAX. OPERATING LEVEL El.2185 CONe APRON f A El.2125 PLATE Fl3 --..... 10---< ALASKA POWER AUTHORITY 16 SUSITNA HYDROELECTRIC PROJECT WATANA MAIN SPILLWAY CONTROL STRUCTURE EXHIBIT F 0~~~~;,;;;;;:3~2 FEETSCALEIe!(1116 INCH'I FEETI SECTION 0-0 u::;~;:;=~==================~:::::::iJ.~ROCK ANr.HORS ,..-- SECTION C-C B .t SECTION A-A 1'1'1'1'1 ACCESS SHAFT1:D rUNOERFLOOR DRAINAGE <; I "~~IJ II:;TIIII f-- <:III,I 25 - :i IRo'r-- 1 I:f---- '0 ,.~I II .'I:I II !!!:11 II V- II '0 II I ......II .~~I'I II ~:.11 ...,II I "T I 8 "0 "<;>-H-II -'-~'t; AOlLlL I II t-o ~ ~~~TROL STRUCT~RE ~II -f--' I L -I..,I' -- 5>I '"I I II f---!I II........ :'1 I "'-I IICD-I:I '-., I ~II I 1 ,T "'T"\' b I I I II-'~!,I II f---..ROLLWAY I II b "-,I Ti I II ~'I ,I II~ 1 L J II I~2~.. 1/~1 r >-- "'-'II ~ v"v I ..""' '"u ~0-' 1 f,'" ! d !ii oJ .j.. HOLES 10'X 10' DRAINAGE GALLERY VARIES I 10~~ H , i ...r<;«: , I ~DRAINAGE ',\1// I" R'oCK ANCHOR~,,"" SECTION B-B (TYPICAL)(PLATE F12) SCALE A ~SPILLWAY ____________I -~'ORIGINAL GROUND SURFACE -201 .------------...'..~.LEVEL I ROCK ------------2 __________ '=11 I'20'--...---....... r---ROCK ANCHORS GALLERY , II " 4' ./- A AERATION SLOTS//r+C AIR SHAFT ]1 .....,,ROCK ANCHORS...................'\,I~l /'/' 7' •0------10'X 10' DRAINAGE DRAINAGE HOLES 80X DRAINS I L~__ 6'X 4' ACCESS AND ---I~~-*I III _~ AIR SHAFT ./'" ROCK ANCHORS/ 2200 2180 2160 2140 I-2120ww u, :1'; z 2100 0;::;; W ..J 2080w 2060 2040 2020 2000 SECTION A-A (PLATE F12) SCALE A STEEL LINED RAMP 4 20 o 8 FEET SCALE 8 ~i""'II""'II"'5~~2111&l (1/4 INCH'I FEET) o 40 FEET SCALE A e:i (I INCH'20 FEET) 6 1_0 11 oco ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT SECTION C-C SCALE B WATANA MAIN SPILLWAY CHUTE SECTIONS EXHIBIT F PLATE FI4 I ACCESS ROAD I EL.l567/ TROLLEY RAILS ACCESS DOOR o~ 1VALVE0"VALVE FIXED CONE VALVE (TYP) ~SPILLWAY I l[VALVE PLAN AT EL 1567 t VALVEq;VALVE "E B EL.1567 SURFACE ACCESS ROAD B t I EL 1600/ "A ~SPILLWAY I I ~.._~80._'--,0,--"<.., I EL.1600/ L.1585 PLATE FI5 i SPILLWAY SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY SECTION C-C WATANA MAIN SPILLWAY FLIP BUCKET EXHIBIT F o 16 32 FEET SCALE ",e==1IIIII1IIIII~;;';';;';'2~(1/16 INCH =I FEET) EL.1600 25 TON SERVICE CRANE EL.1605 EL.1620'--------.--- SECTION E-E 10~ I ,SPILLWAY 6-78"DIA FIXED CONE VALUES AT 2E;'CRS. SECTION B-B L-_ I' I--..,.~-~-":';.---+"--l#-+--f-- Ii"", I SECTION 0-0 GUARD RAIL EU600 !---=c=--==:--------m, ,-- ROCK::-:::-:-----'I' ANCHORS ~-\ II -I 20 1510 ,-2'-0"MIN.CONCRETE FACING EL.l620 SECTION A-A (TYPICAL) 90"DIA. RING FOLLOWER GATE EL. 1560 ('7lt::::::~~~z::;:~::::::~:r EL.1589 L_J---tt--25 TON MONORAIL HOIST (2) TRANSFER TROLLEY <:.....~~~~~~~LI-,:1J~;:::~==lF;:~R:~E~L~.,5~6~7r'..78"DIA. FIXEO CONE VALVE 't:====::;;;;;::;;~CI,..l.-.Lill:-.L-l---t~j~~_E~DL,~~ATING JACKET 20 40 100 -----=E·-R'AA1UTHORITY--I ALASKA POW C PROJECT HYDROELECTRI _I- ,SUSITNA NA WATA TIES OUTLET F~~~GEMENT GENERAL A PLATE FIG EXHIBIT F \/2-':.~~=_=~\ I ~{~~i~~~-T .0-£.:::.~~=:.===~ I?-SO <'000 ~",o-.-,"oo ~Oo ~ \~190 0,-. 0~,~' ,"'0 •. •L .M :"'~,,1 HICKN~SS 2 SECTION B-B SCALE C 20+00 SECTION A-A SCALE C ~wc~~m:;E5~'" ,~,'?' ,"'0 -----./.STEEL LINING P LAN SCALE A 15+00 IN FEETSTATIONING DAM SECTION C-C SCALE C -- PROFILE SCALE A ~ffl?Ilt/.§r!V.a!['Z" / L DIA =2a'CONCRETE LINED TUNNE . 10·00 / NO SURFACEORIGINAL GROU TOP OF ROCK ==::::r~--T--~-~""'=M"~·.7-~N:'~S~P~I~~:;=-~Y=·~------'~'==~==:::::::::':":'~7.c::::--=:::::::::::~....._+-_....~_==:::::~~.'__"ouruue ~<, DETAIL I STEEL MANIFOLD CONCRETE,r ~~~i::KNESS =2.5 STEEL LINING .~--~'---~-.~Ti _;, +"---I ~l «,"J-"--"-----r "-a'DIA.FIXED CONE VALVE (TYP.) 5+00 PLAN SCALE a '-'-. / DETAILS FOR PLATE FI7 '", GATE ==';:'::::=====-~l-;S~~P~~ILLWAY CONTRO"""""'"'""""~~-, "B I --i OF NO.6 INTAKE ~L__~__'_3-- T~O;;;-P;:'EN"'I';;N"':'-"O'-'W"'E'-'-R"-'-NLTA-K-E-_-_-_-_~~::I-_.--_~=E--=~~~~~==-=-:::===-=-__=-- STRUCTURE l-,~»->:~._-~.....,/i-,B CONCRETE ~SSiLJ.A\EBI===:::;:r--:j;=-:::-:::-::-=--=-::::-:::-::-=--=-:='-::::- TRASHRACKS ----,---HI OF TUNNEL A t 'b, "0 <D ~----of------I ~----_d, ~----Nf------I A .t TRASHRACK (TYP.) FLOW------ PLAN AT EL.2200 .--·-GATE HOIST TOWER SUPPORTS ':>-LADDER -HANDRAIL POWER INTAKE STRUCTURE PLAN AT ~TUNNEL TRASfjRACK PLATE F 17 (1/16 INCH =I FEET) SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY 16 32 FEET WATANA OUTLET FACILITIES GATE STRUCTURE EXHIBIT F o ISCALE EL.2201 ~==--l_----r----__....J SECTION B-B '0 1111111111111 lV""aoisrTOWER ---11J <. 'II .>1,Iliil Jilt ~I /' -----f--.'..-- ! I ,! I I I I EL.2125 il !I§l1k.§f1li'! <Il,,,~..;'f. a:,~t....~ I ,I TRASHRACK~»>1m •l'i ~~-, I ~, I I I EL.2025 EL.2027 \I ~ ~-;1I1\EL.2022 'r -a-=\'1\- EL.2201 III rEND OF CENTER PIER /",_.. / EL.2022 -----< --_______ROCK ""----<;.,ANCHORS ~ SECTION A-A i Ir--. r--I--H! I ~ EL.2027 LI'------'I rrll GATE HOIST__T_O_W_E_R_--l~"" STRUCTURE G <, {/ 1;<, -~". "" EL.2025 ~/I, 9'-0"6~"11-0 \/ARIES V'NTAKE GATE .> -----< I 1[/ I I I -' ~ ~ f, \ ",0 'l-' / I I PLAN SCALE A 20+00 C o 50+00 BANK)--"~----+--------+---4 40.00 -.=1=----:::::::------:-_ ORIGINAL GROUND SURFACE (NORTH ORIGINAL GROUND SURFACE(SOUTH --.-------"--....- STATIONING IN FEET PROFILE SCALE A --=-=----.,-----.. 20+00 I "-" .'111'1_ r ROAD /FUSE PI.UG/ BRIDGE --..,~..:-.-.---:7""._~.. 2400 I-w 2300w LL ~2200 z 0 2100i= '">2000w oJw PLATE F 18 SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY WATANA EMERGENCY SPILLWAY EXHIBIT F CHANNEL -------"?TOP OF ROCK",-.•__••~I •.~. ORIGINAL GROUND SURFACE- SECTION C-C SCALE B 10 20 FEET0 SCALE C E__.__~_----------J (liNCH =10 FEET) 0 50 100 FEET SCALE BE ](liNCH =50 FEET) 0 200 400 FEET SCALE AE _.(I INCH =200 FEET) 2150 .....-------------------1:.::.::.:..:....::...-----------1 2050 ~-----=~a'@!i~i==_-----_+------7-------_j 2000 L-----------'I..-~"'Am"""7iTf<=I'__i-----__f--------.....J. 15 %SLOPE CRUSHED STONE OR GRAVEL 3/4"TO 11/2" /""6"FINE FILTER PILOT CHANNEL EL.2200 SECTION B- B FUSE PLUG SCALE B FUSE PLUG CREST "-LJ-.g.0' I. ROAD 1-CHANN<.L ~~~~~~~~....., ORIGINAL GROUND SURFACE ~~'---------- ---------------TuP OF RO~.._.. ..--"1"-" 2150 2300 l 2250 ~.4 -.-""'-=---__~.,.L_"-_'--;t'---I --:'J I fCR USHED.~SiT::-O"-N_E____=_~~'""----------___:-=-::_=_-----------lIOR GRAVEL..4"L,c-/-'--'-'--,L---/-----._-TO 3/4"~ FINE FILTER / PILOT CHANNEL : !4'I 10'14'I : >--------.----.----------...1 CONSOLIDATION GROUTING AS REQUIRED NORMAL MAXIMUM OPERATING LEVEL 2185 RIPRAP SECTION A-A SCALE B EL. 2170 ~CHANNEL _______=RI~~G~..::.~~~-__._.----TOP OFROCK~.... ..___•._••-.,... 100 5 iEL.2210~/.ROAD BRIDGE ,-ROAD ""'~-::I 11~INORMAL MAXIMUM i~OPERATING -LEVEL 2185 j-310' 2250 2150 2200 2300 ROAD 8RIDGE 2-160 L --1 2200-·.....-----l--+---+--l-l------j I-2190 L----1~I--+--++-----jww LL ~ ~2180 i= ~w~2170 ~~--r--LL_+-_..I....J.:T7iii~~ I-w W LL ~ Zo i= ~w oJw SECTION THROUGH FUSE PLUG SCALE C ---~DOWNSTREAM pLUG_ 1 EXPANSION CHAMBERP G L;r;J...---:--- UPSTREAM LU - ---------------------------------------r-----r-------------... ~-z z~HIGH PRESSURE ':!E f:1 ~~~SLIDE GATE ,J , 00I0 '"/«i -""'"'"=N 11,=",1 >Jill·'''I/-:;'Hlv i ,,~" V l L ~<l f--ltJJU473-S6 <i D<i.--------------------FLOW I -I Ii:.E L.I4E;7.JlZ ___'0>--- i5 zs TIJi'llii::L ------,--------'"0 -----_..~=:-..~,--:~--.~---~-~...,.......-=-------------{J;. i eo-0ai~H ,.;r "'ro -"SLOPE1:=< < < < < """11.1("'/\\1 '""JI I l\-ordl .1.7!1'~I'-O;<l1l2- !20'Ol .1 0 ,"II,~uv I-Ii'0 0 120,0'100,0''"N 10 ,0'20,0'160_0'«i 340,0'...._.._------------~---- SECTION ALONG It OF TUNNEL NO. I <i.TUNNEL I SECTION C-C SCALE B 7 1_611 x.111_611 GATE OPENING ;..t---1=~3"DIA,PRESSURE RELIEF HOLES EXISTING CONCRETE TUNNEL LINING STEEL CONDUIT LINING SECTION B-S SCALE B It TUNNEL AND GATE <i.GATE GATE CONSTRUCTION DRAIN BYPASS PIPE----t----l1--..L_1 GATE HOIST SUSPENDED METAL~ ROOF GATE CHAMBER FLOORIi:.TUNNEL SECTION A-A SCALE 8 SCALE A ..J UJ Z Z C+w 11\-I'GI\1 EXISTING CONCRETE J TUNNE L LINING __ GATE HOIST GATE CHAM8ER FLOOR (EL,1480) BYPASS PIPE ------------------- -GATE BONNET LOW LEVEL OUTLET UPSTREAM PLUG SCALE B S" SUSPENDED METAL ROOF SHOTCRETE LINING B+i CONSTRUCTION DRAIN I+A ~,-~'--=-"------+-~-~"--"------t----------''-'-----=---c+I ,.A ---------1-,.- I I I I __---I.,..-=-==~.J-.J- FLOW---- 16 30 SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY WATANA EMERGENCY RELEASE SECTIONS o 32 FEET SCALE B 'I'!I~~~:';;iiiiiiiiii~1 (1/16 INCH =I FEET) o 60 FEET SCALE A E ijijjl (I INCH =30 FEET) INSPECTION GALLERY SECTION F-F SCALE 8 TUNNEL 12 3"DIA PRESSURE RELIEF HOLE 7 1_611x 1jl_G"GATE OPENING METAL ROOF STEEL CONDUIT LINING SECTION E-E SCALE B EXISTING CONCRETE-- TUNNEL LINING CHAMBER~ DRAIN GATE --__ BONNET GATE---~ HOIST <i.TUNNEL SECTION D-D SCALE B STEEL CONDUIT LINING ACOUSTIC DOOR ..J UJz INSPECTION ~ GALLERY f-- F., -1-= I"'I"E.., LOW LEVEL OUTLET DOWNSTREAM PLUG SCALE 8 SUSPENDED METAL ROOF GATE------.....n BONNET EXISTING CONCRETE TUNNEL LINING FLOW - 18"DIA, CHAMBER DRAIN EXHIBIT F PLATE F 19 EL.1440 EL. 1465 STOPLOG GUIDE EL.1500 ET TO BEFLIPBRUUCC\ED AFTERCONST DIVERSION ~"»>I I I'----'l-_ 40 SECTION D-D POWER AUTHORITY ALASKAHYDROELECTRIC PROJECT'------=SUSITNA WATAN~ORTALSDOWNST~E~~CTION-,-,S=---__ PLAN PLATE F20EXHIBIT F OQ~~~§__iiiii8!FEET (lINCH =40 FEET)SCALE I~ ooo CO ;!: Z --<i.- SECTION C-C r CONC.FACDIN~O ROCKANCHORE ----- ~••,.....<~-- EL. 1405 SECTiON a-a ROCK "<.i SPILLWAY'.~l 1480 1680 1520 1440 1720 1400 1760 ....wwu, ~ zo ~w --'w /' 1520 N3 227 500 ---.1750 ---_-:;;~___I----_\ 1440 ooo '"rt z SECTION A-A ,J DIVERSION Z "-TUNNEL NO.1.....~~fi~r.-_§II~_ili~1400 -170 1640 ....wwu. z zo;:: ~ w 1480--'w PLATE F 21 SPILLWAY FLIP BUCKET ( I INCH =100 FEET) ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT WATANA POWER FACILITIES GENERAL ARRANGEMENT EXHIBIT F SCALE ''''''''''~~ \ P -OUTLINE OF DAM CREST //- // // /// -r:--v-_--....,..~"..,/--~:.._..L /-r -:=;.r-~ // / ACCESS SHAFT ,....------- 00 o",""-FACILITIES ,,/ GATE STRUCTUR -OUTLET POWE / PENSTOCKS /;R INTAKE BUILDING LAN SEE DETAIL PLATE F24 ,,;~0::>,,, I CONTROL BUILDING (PROJECTED) -------------------J..}-~L.2240 e:'0RIGINAL GROUND »>:TfstIT -e:_SURFACE II ~ II 0 II II I I Ii ~-- ~ I I IIII - II I I II --------- I I I I' ---------------EL.2025 ~ I'I I II -c-, dll''''''1\ I I'---====------'I I I I' " ._----'I I I II -~ CABLE SHAFT ",,--1 I I,I II,I I l--ACCESSIII I SHAF1;,(PROJECTED) <, " I'I I " -, II " <. I'I : II ,I 'Il'''-VENT SHAFT " ,I I I ,I 0/17'1.0' " I I ,I PENSTOCK (CONCRETE LINED) , " I I 'I " I I 'I I:I I :1 ~I,I I II TRANSFORMER ~:'I I I: GALLERY "I II'\,'I II ~, I I GROUT a DRAINAGE -~ROCK !u:'I SURGE CHAMBERGALLERY",'II BOLTS I POWERHOUSE:I -_._------ EL 1507 \,,II,';U.(,---34'MODIFIED HORSESHOE "I ""R CONSTRUCTION ADIT LI/7~ '"EL 1500-.:~OCK BOLTS . CONCRETE LINED ~hL.1463]I ~? TAILRACE TUNNELS EL. 1420 ',-j-EL 142?:-I VEL.1425 "/111\ ~I\I.:N#~'J LCONCRETE l ~F lJIL . PLUG '~11I\,,711~ 200' ~'q)I""'I111\" STEEL LINED I PROFILE 2200 2300 2100 2000 ...1900wwu, :!: z IBOO 0 i=..>W ...J 1700w 1600 1500 1400 1300 PLATE F 22 SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY EXHiBiT F ,AIR DUCT 20'DIA. WATANA POWER FACILITIES ACCESS ~COUNTERWEIGHT ELEVATOR o 8 16 FEET SCALE B ~i~~~iiiiiiiiiiiiiiii~!(1/8 INCH'I FEET) o 100 200 FEET SCALE A i !(I INCH'100 FEET) CONTROL CABLE AREA DETAIL SCALE B ~SURGE CHAMBER ACCESS TUNNEL SURGE SHAFT VENT PENSTOCK CONSTRUCTION ADIT SURGE CHAMBER - -ACCESS PORTAL ISOMETR!C SCALE A POWERHOUSE .../ DRAINAGE CHANNEL TRANSFORMER.../' GALLERY \~O POWER '(TAKE EL 1560.0 -.1 I 25'-0"II-----'~~----~-_.~-----.1 SECTION D-D SCALE B / I 0, I SURGE CHAMBER ACCESS TUNNEL SURGE CHAMBER .EL.1500.0 I•! -ACCESS \ tv3 SHAFT ';:;:9 ,000 -DETAIL I SECTION B-B SCALE B I I~---------! PLAN SCii:I'EA TRANSFORMER POWERHOUSE GALLERY o-r k (NOT IN PENSTOCK "0:. ~'?I,~g~NRUCTION DRAINAGE N (X)r-CHANNEL SECTION A-A SCALE B o, (X) N /'- TAILRACE "\TUNNEL '----.--Lr-: -Jl"'""'"'"REQUIRED (TYP.) \ I \ I \ I TAILRACE~ TUNNEL STOPLOG GUIDES DRAFT TUBE1/GATE GUIDES -,~I ,~". DRAFT TUBE GATE GALLER~,.--.--------- SURGE CHAMBER ----1+++- TUBE GENERATOR I /ROCK SUPPORT AS REQUIRED (TYP,) I I I \ ~ If'.-. ------~~--------~~~--------------~-~~~~~~~-----~._._----_.~._-~-------------------------., --- - - -~-L-.-_ I I ----------~_.----------~~--_._-----~+------_.~~~---- I ~ 1 I I LINED /GROUT ~GALLERY ~ ~LLPOWERHOUSE~CRANE 1 /CONCRETE /_PENSTOCK ,I i I------------~---------.-----------f__---.~-~---~--~------------------------~-----------------------~~~-.~---------------------------------__j ROCK SUPPORT AS -\" REQUIRED ~f__:"~----~- TRANSFORMER"\ I ~ GALLERY '"\I----.... I-------------~------~-----------~-~I~-~~---~-~~~~-~-------~~~ /-CA8LE SHAFT, ~-~-~~-~~~----~-----1608 1592 1576 1560 1544 1528 1512 1496 I-ww 1480u, ~ z 0 1464f='§! W ...Jw 1448 1432 1416 1400 1384 1368 SECTION A-A SCALE B ACCESS TUNNELS PLATE F 23 16 ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT WATANA POWER FACILITIES PLAN a SECTIONS 100 EXHIBIT F o 32 FEET SCALE B ~i~~~iiiiiiiiiiiiiii~!(1;16 INCH'I FEET) o 200 FEET SCALE A i !(liNCH '100 FEET! CONCRETE LINED PENSTOCK-:CONSTRUCTION ADIT -CONCRETE PLUG 1400 1416 I----/--/-.--=------------'r--------------------==~+____i 1432 1-l-------1--/--/--/-.L-.L------"-7~_7~---""~----------+____i 14641---------------- 1480 r-----~ I- Wl:'14481-----~.L-----------__c~-__"<----*-----------____i TAILRACE TUNNEL -c..SURGE CHAMBER '""POWERHOUSELTRANSFORMER GALLERY ~PENSTOCK GROUT ~ GALLERY PLAN SC'A"C"E"A SECTION B-B SCALE B o / NCY Y L ~I ~--"--;'+--TT -;'r----~I 1 --- iii i : I II Ilii II I II II II ,II 'II II II j/:'\J7 i I'II II II II .II 1\I : I1/ ,I I I I I 1\I I1/I ~W',,'I I ~--~I \I I \ ,I I <,I-I---'l-----f---~-'-'L·-~m---tJ~~~r-,EMERGE ~~~t ' ,I .t '\SPILLWA I I'I \CHANNE t/tf i -.F'~iW .~H ~l ;;~"!EL.217 I I I I I I I [ I I I ,, "<, 4'·..~'/--1 I I I III I I I H -'"I I I I I I A ---+j.!LLj I IIt'-I r --,-I I I .."<,.- --H "'~L,-------_~I _/1 I ~I ~I ':J r!:.c v--l---~ I ~:~:~cl INTAKE I d INTAKE I INTAKE INTAKE }INTAKE .~INTAKE .I~NO.6 NO.5 NO.4 NO.3 '30 1.0"i 20~Oll 30~Oll I 20~OIl 30!...O"20 !..011 30!.,O"IO!..O" NO. 2 NO.I -I .. / EL.2025/ I I I I PLAN AT EL.2040 PLAN AT EL.2116 PLAN AT EL.2205 1 - --1 INTAKE GAT TRASH RACK BULK HEAD GATE SHUTTER ~ -jr---- l'ICE BOOM --,L GUIDE 11L._.l--------J~L1NKED STEM I--METAL SIDING ,.B I---STEEL COLUMN I--f----HYDRAULIC f-__CYLINDER ·r-------AIR VENT EL.2201 p"'='''= BULKHEAD~ GATE GUIDE \.o-I----SHUTTER1"-GUIDE ~9'5' /50 TON OVERHEAO CRANE ~1~1~1)(~,,1/171/r/!/. --iEJ="IIlt~--r-------------f111 EL.2236 HIGHEST LIFT I ICE dOOM-----. GUIDE TRASHRACK- (TYPICAL) 35 TONCRANE- SECTION THRU INTAKE GATE CONTROL STRUCTURE (1/16 INCH'I FEET) WATANA POWER INTAKE SECTIONS SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY 16o OM o ,INTAKE (INTAKE ilNTAKE INTAKE NO.6 NO.5 NO.4 , I NO.1 EL.2201 I I I , 111---------Ij \1 II Ii II I II mII I J§lW.L.I I I II \I I 1\\ EL. 2185 II I II II\I II EL. 2185-I II II II II I ~~~ I I II II II II fIIrnfhII I I--TRAVELING ICE BO L il liJ II II I I EL.217II I I '~'Ii I'I I 'C;I"'!"'"<1\1I'? I I I I II II I IIII I I II ,I I I OUTLETY I I I II I 1 I I I I II II I I I I II I FACILITIES I II II Ii I I I INTAKE I I I ~II II I I (SEE PLATE F17) I I I[II I I'~+J I III II I I II i~~11I1 I I I ;1 II _'iIIIII I I , I II II I -I I I II :1 III, I I I I II I'I I I IT .II r 1 II II I I I I I II II II'-II II[tt3 II I II ,I I I ~IOI I Ii II IIIIIIII I I I :I III II II I I I .I II II I I I I I ' I 1'1 II II I I I I I I I III :1 II I II1 I I I II I >~I 1..I I I II II I I I II ::I II I I IIr~j th I I II II,II II I d L H.J I I I I I I II IIIIII[II I,I I L---------TRASHRACKIIIIIIII I I I l I I »>,I :~ I I I I I I I I I I I :::I I SCALE !Ii I ,I I EL.2025 EL.2027 1-._________________.__.!..._______...l EL.2021------- I I • I.50 !..O II 501_all 50!..OIl -n r~"'''"'''''''' HOLES TO HEADPOND (TYP.) lBULKHEAD GATE, 19!..OIlW x 23.I_O"H (2 SECTIONS) SHUTTER '0 NO. I ~ N SHUTTER '0 NO.2 "6 N EL.2030 SHUTTER 0 NO.3 ~ N f--__.·0f--- ~-!!I-- STRUT(TYP) f-----:<1 i- !Q1"- 1"-- '",.. f-- '0 -'<0. N .L...--jfHI-Irlr--- TRASHRACK- GUIDE EL.2025~l- ""'=,="" MINIMUM OPERATING LEVEL EL.2065 FRONT ELEVATION SECTION A-A (SHUTTERS OMITTED FOR CLARITY ) SECTION B-B UPSTREAM ELEVATION EXHIBIT F PLATE F 24 o, .1 o oo DDDoOD ELEVATOR~ I UNIT 6 PLAN AT EL.1444.0 (GENERATOR FLOOR) EQUIPMENT HATCH 151_6 11 fUNIT4 240'-0" PLAN AT EL.142~2=.~0 +~~;:;;;~~;~~~~_ (DISTRIBUTOR LE-VEL) .1 °f'UNIT 2 DRAFT TUBE ACCESS ( TYP) 60'-0" I. 45'_a" i I PUMPS I I BELOW FLOOR 60'-0"(TYP.) ( 1/16 INCH =I FEET) 160~1III""'~~_iiii3~2 FEETSCALEi=' o 4 I [ I,I H H H ~--1ii\\11 11\A''\--7 DN. H SERVICE BAY ELEVATOR ~.MAINTENANCE ~HATCH 1101_0 II EI2 UNIT 6 H H H D D ------_._--------- HH 240'-0" t UNIT 5 I FIREWALL I HHH PLAN AT EL.14630 --------------';-,='POc:W"'E=-=R""H'=--OUSE FLOO~R::-)::::.....---- H D -, EQUIPMENT HATCH 60'_all WASHROOMS 50 1 _a" BATTERY ROOM ACCESS SHAFT LEGEND SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY WATANA POWERHOUSE PLANS PLATE F 25 EXHIBIT F POWERHOUSE PLANS GENERATOR CIRCUIT BREAKERS 15 KV ISOLATED PHASE BUS GENERATOR TERMINAL CUBICAL GENERATOR NEUTRAL CUBICAL UNIT AUXILIARY SWITCHBOARD RELAY BOARD TURBINE GENERATOR CONTROL BOARD EXCITATION BOARD EXCITATION TRANSFORMER MAIN AUXILIARY SWITCHGEAR AUXILIARY SERVICE TRANSFORMER 7.5/10 MVA AUXILIARY SERVICE TRANSFORMER 2 MVA GENERAL AUXILIARY SWITCHBOARD ESSENTIAL SERVICES SWITCHBOARD EI E2 E3 E4 E5 E6 E7 E8 E9 'EIO Ell EI2 EI3 EI4 UNIT I UNIT 2 UNIT 3 UNIT 4 UNIT 5 UNIT 6 ~<t.Ii.Ii.Ii.~I I ~A ,,..S ,.C '111/I I "-=,,,.I/ I I EU514 El.1463 EL.t422 El.13BI EL.t433 Ell399 EU444 EL.1496 '0 -'gJJ ~C l II ---'--'r\----I +..L--+--I--'_hl----+-_-+_--+--+-_+-~,.---------'-- I I I II ~ ~~L..,,------,-~J-'----.---1_.---'- ~ I I" 201_0" §~ I!rOWERHOUSEACCESS " ELEVATOR ~ I ~,- ~A ..S STRUCTURE LONGITUDINAL SECTION (THRU CENTERLINE OF UNITS,UNITS NOT SHOWN)UNITS PLATE F 26 SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY 16 WATANA POWERHOUSE SECTIONS ACCESS TUNNEL EXHIBIT F SECTION C-C SECTION THRU SERVICE BAY o 32 FEET SCALE "'I~~~__ilii'(1/16 INCH'1 FEET) EL.1514 El.1463 El.1444 EL 1476 EL. 1399 EL 1444 ~POWERHOUSE UNITS EL.1514 EL.1393 a.1433 I-----~------ ~-._---------- f----------- TURBINE • - SUSPENDED CEILING ---l--t---PIPING AND VENTI lATION GAllERY =/1 1 H--~-·Ii.DISTRIBUTOR ~POWERHOUSE I 74'-0" 11----'>=="-----~·-------::=1t_~205 TON POWERHOUSE CRANE (2) EL.l496 EL.1514 El.1433 .13 EL 1399 Ell444 El.1463 ~~----:--~--~- L-------L----_---.1-- DRAINAGE AND DEWATERING GAllERY SECTION A-A (SECTION THRU CENTERLINE OF UNIT)SECTION S-S (SECTION THRU BUS TUNNEll TO MAIN ACCESS SHAFT -DELUGE VALVE ~OILROOM B6 ·0 ~FIREWALL IJI ~--'r~~;V I@O!QO~~'.,"~J~·II !:::::=====:!!:====!!=,--=_=_=--==~...ll-~~ t =III~'"',,1''<--11'''"~'"",,'"''''''f''~~OIL STORAGE TANKS CABLE SHAFT SPARE TRANSFORMER No 2 ,.A -El.6':0,-"---------r':-0-"-i"1-------.-__.__86'·0"------ l DRAINAGE SUMP ""0, ro DRAINAGE PUMPS -./ 66 /BUS GALLERY "V' 77 1_0"·1·120'·0".1.-,A PLAN SCALE A CABLE SHAFT f C l C PLATE F27 ALASKA POWER AUTHORITY 8 4 16 WATANA TRANSFORMER GALLERY PLAN 8 SECTIONS SUSITNA HYDROELECTRIC PROJECT EXHIBIT F o 8 FEET SCALE C ~I~~~iiiiiiiiiiiiiiiiiiiiii'(114 INCH =I FEET) SCALE B ?11FEET u/s INCH =I FEET) SCALE A ?31FEET (1116 INCH =I FEET) 345 KV CABLES INSPECTION HOIST SECTION C-C THROUGH CABLE SHAFT SCALE C ci '",., r-- DRAINAGE PUMPS STAIRS -CABLE TRAY SECTION B-B THROUGH BUS GALLERY SCALE B ~_'.0_"_1 /ISOLATED PHASE -,----.J"""''--Jli(§y,"/BUS o, ~ AIR DUCT flUS GALLERY /:ISOLATED PHASE / BUS MONORAIL BEAM OIL SUMP COLLECTOR PIPE SECTION A-A SCALE B /---.....:') I II I I I I I I 345 KV OIL FILLED CABLE o, ov 15/345KV I¢ TRANSFORMER ----+-+---J-----r----r---tjH-- SECTION D-D THROUGH SUMP SCALE A l C EL.1425 TAILRACE TUNNEL DRAFT TUBE GATE GALLERY SECTION A-A SCALE B --~-----~--~.,.;q.-H-rl SURGE _--'71 CHAMBER CRANE itii~:EE~~~+-O+-l STOPLOG GUIDE SURGE CHAM8ER -~l-I++---NORMALx«EL.1455 ~ DRAFT TUBE DRAFT TUBE GATE GUIDE 0 R L -=------------------0 ~,'~-----~~-~r~RIGINAL GROUND SURFACE •------------'-c-; (TUNNEL I )::z:'---...._~ 0 ORIGINAL GROUND SURFACE -~'~ 0 (TUNNEL 2)~~-~-.<.~'''''-.~ <, ............,~,TAILRACE PORTAL 7<.;TUNNEL I- '\TAILRACE \/ p'-i~SURGE PORTAL CHAMBER TUNNEL 2 FLOW TAILRACE TUNNEL ~ ~S.,-'\ I -",./H~h1 '7",-, s+l 190 1300 1600 220 1500 200 230 1400 2100 I-w W LL ~ z 1800o li'"w uJ 1700 o-'o '" t UNIT 6 "AtUNIT 5tUNIT 4~UNIT 3tUNIT 2 DRAFT TU8E (TYP) PROFILE SCALE A ~UNIT I Iw 60'-0" 2 ~611_1 19 _all 2 1-611 (T~ ROCKBOLTS AS REQUIRED PLATE F28 SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY EXHIBIT F WATANA SURGE CHAMBER AND TAILRACE SECTIONS-'A 0 8 16 FEET SCALEC I !(118 INCH·I FEET 0 16 32 FEET SCALEB I I (1/16 INCH·I FEET 0 100 200 FEET SCALEA i ,(I INCH·100 FEET SECTION C-C SCALE B TAILRACE--f-t--P-~TUNNEL (TYP.) 34'~l2'-0" (TyP)(TYP)i TUNNEL I ,-.1- CONCRETE LINED TAILRACE TUNNEL SCALE C SECTION a-a LEGEND NOTES SYMBOLS:I.SUBSCRIPTS 21 -DISTANCE RELAY 0 T --TRANSFORMER A C GENERATOR.3 PHASE.60 HZ.-c-o 0-111--LIGHTNING ARRESTOR WYE CONNECTED TN --TRANSFORMER NEUTRAL 21GB -GENERATOR BACK-UP RELAY J.,J.,TSS - STATION SERVICE TRANSFORMER 26 -TRANSFORMER THERMAL DEVI CE ~g-TRANSFORMER -1H~H'CAPACITOR COUPLING ET -EXCITATION TRANSFORMER VOLTAGE TRANSFORMER DG --DIESEL GENERATOR nTh AUTO TRANSFORMER G RECTIFIER R --REACTOR GT - GENERATOR TRANSFORMER -0-CIRCUIT BREAKER F --FIELD 27 UNDERVOLTAGE RELAY P -PRIMARY - -<(;-~4>-ORAWOUT CIRCUIT BREAKER B - BACK UP 40 -FIELD FAILURE RELAY BF --BREAKER FAILURE -----..LOW VOLTAGE AIR BI -- BUS NO.I 41 -FIELD CIRCUIT BREAKER ---CIRCUIT BREAKER B2 - BUS NO. 2 46 -NEGATIVE PHASE SEQUENCE RELAY LINK IN ISOLATED G - GENERATOR~PHASE BUS 49 -THERMAL RELAY GI --GENERATOR NO. I ~-DISCONNECT SWITCH G2 --GENERATOR NO.2 50 -INSTANTANEOUS OVERCURRENT AT -- AUTO TRANSFORMER RELAY ----11 1 GROUND CONNECTION C --HIGH VOLTAGE CABLE OR 51 -TIME OVERCURRENT RELAY OVERHEAD CONDUCTOR TC --TRANSFORMER AND CABLE OR --00-RES I STOR OVERHEAD CONDUCTOR 51N -TIME OVERCURRENT NEUTRAL RELAY ---<BJ::Q)---RESISTANCE TEMPERATURE DETECTOR -0-STANDARD DEVICE $CURRENT TRANSFORMER 6 TRANSFORMER CONNECTION 3 PHASE.3 WIRE.DELTA 59 -OVERVOLTAGE RELAY Y TRANSFORMER CONNECTION 59VHZ -VOLTS PER HERTZ 3 PHASE.3 WIRE.WYE 60 -VOLTAGE BALANCE RELAY m1l REACTOR -3E--VOLTAGE TRANSFORMER 63 -GAS PRESSURE RELAY 64F -GENERATOR FIELD GROUND --lE-CAPACITOR BANK PROTECTIVE RELAY 64 G -GENERATOR STATOR GROUND ~BUSHING CURRENT TRANSFORMER PROTECTIVE RELAY 71 -OIL LEVEL RELAY 79 -RECLOSING RELAY 81 -FREQUENCY RELAY 84 -EXCITER VOLTAGE BUI LD-UP MECHANISM 87 -DIFFERENTIAL PROTECTIVE RELAY .1 ALASKA POWER AUTHORITY I SUSITNA HYDROELECTRIC PROJECT ELECTRICAL LEGEND EXHIBIT F I PLATE F29 SWITCHYARD SWITCHYARD SWITCHYARD ..=. SWITCHYARD SWITCHYARD SWITCHYARD ~lSPARESTATION SERVICE TRANSFORMER NO.3 2000 KVA,15000/4BOV 6 Y 345 KV OIL FILLED CABLE 11r---"l...A...JJv y 34.5 KV CABLE G4 345KV OIL FILLED CABLE STATION SERVICE TRANSFORMER NO.2 2000KVA,I5000/4BOV Y ~~-6--~/--+--''-----:---<'-------III AUXILIARY TRANSFORMER NO.2 (SURFACE FACILITIES) 7.5/10MVA,15/34.5KV DIESEL GENERATOR 500 KW,0.8 PF 480 V,311l,60 HZ. 51 N "BLACK START" BUS 480 V MAIN AUXILIARY SWITCHGEAR AT SURFACE G2 r<;» 87 C EXCITATION 3 TRANSFORMER 3>--PI'''--<I:::D--+-. TRANSFORMER 3 X 145 MVA,15/345 KV:5% FOW,55°C 345KV OIL FILLED CABLE SURGE PROTECTION L...J;::r1,,11 c P.T.15KV 1120-120V C--@@@@ t --TO GOVERNOR CONTROL P.T.15KV/120V~--METERING .AND SYNCHRONIZING GENERATOR:1901218 MVA,0.9PF 15KV,311l,60HZ. 6O/BO°C.225RPM I A-t---...AV R T IIt-----t::k::f------, GENERATORrCIRCUIT BREAKER ISOLATED PHASE BUS ~_..- ~£ILIARY TRANSFoRMERY6NO.1(SURFACE FACILITIES)I ~7.5/10 MVA,15/34.5KV : 7....~ 41 34.5KV CABLE fIT T D.C.FIELD JJFLASHING ..--...-:-----'..--...41 R) GROUNDING TRANSFORMER NOTE: GENERATORS G2, G3,G4,G5,G6,EQUIPPED EXACTLY AS GENERATOR GI. ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT WATANA POWERHOUSE SINGLE LINE DIAGRAM EXHIBIT F PLATE F30 TO GOLD CREEK... 800'-0" --- II II II II I', II II I II II I II II , I,II I II II I II I I II I III,In.II I IIIII II I IU " I I II I 345 KV , II I I.n,I'I IIIII "I I "u Il II c;=J II SWITCHYARD PLAN SCALE A J 'L RELAY BUILDINGJ ---------------------- o <D '0 I I, I -3 t 3t;-l- I T I 1 1 L--+---IH3rLf----I li - 345KV BUS B I '--J,J, '----+--t+---.\---j~~>---jl' 'I p ",.[P .r .r "~ 5 BF t--~II METERING 3 T,..----I--+--+-----'~\Ht___l_iHI' 'I ,..- 'I r- P R 1 345KV BUS B 2 I I I SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY 100 200 FEET I (I INCH'100 FEET) o SCALE A iV-345KVCABLE I ! POWER HOUSE WATANA UNITS 586 cl-345 KV CABLE I I t POWERHOUSE WATANA UNITS 384 87GT87C r345 KV CABLE I I j POWERHOUSE WATANA UNITS I a 2 WATANA SWITCHYARD SINGLE LINE DIAGRAM AND PLAN SINGLE LINE DIAGRAM EXHIBIT F PLATE F31 o PLATE F 32 PROPOSED ROAD PROPOSED RAILROAD PROPOSED TRANSM ISSION LINE +--+--t EXISTI NG RAILROAD EXISTING ROAD LEGEND- ACCESS PLAN PROPOSED ROUTE SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY 2 EXHIBIT F o 4 MILES SCALE io',............~iiiiiiiiiiiiiiil!(I INCH =2 MILES) STORES WORKSHOP DO 0 000 CEMENT STORAGE GENERAL STORAGE AREA 600'BREAK I '"::,:::"~~"~_I_D~H x ~~~_G_EN_E_RATOR-----EJR'460' ENGINE TURNAROUND ""0 Q 12' RUNNING SURFACE 4"GRAVEL SURFACE 3/4"MINUS 9" BASE -2"GRADE "A" NFS SUB BASE THICKNESS VARIABLE 17' _2% TYPICAL 'SIDE BORROW' SECTION SCALE B SIDE BORROW TRENCHES BACKFILLED WITH PREVIOUSLY EXCAVATED OVERBURDEN 12' RUNNING SURFACE 44' 1.5 H' 1V IN OVERBURDEN I H ' 2 V IN ROCK 4"GRAVEL SURFACE 3/4"MINUS gil BASE _2 II GRADE lIAIi NFS SUB BASE THICKNESS VARIABLE TYPICAL 'SIDEHILL CUT' SECTION SCALE B 17' 22' FILL SLOPE VARIABLE DEPENDING ON HEIGHT OF FILL PLATE F 33 ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT ACCESS PLAN TYPICAL DETAILS 10 20 FEET,(I INCH·10 FEET) 200 400 FEET,(I INCH'200 FEET) 5 10 FEET,(I INCH'5 FEET) 100 200 FEET,(I INCH'100 FEET) EXHIBIT F 0 SCALE DI 0 SCALE ci 0 SCALE BI 0 SCALE AI 30' I 0 I 5',2'I ~~/"'"i~>-"U1 1790' 140'1250'2 (Q)200' ~._....~-- CUT,r-c,--rITI1I ~~1rF~~10/ 0 --.-----._~--- --1".,43 -,-_..-~-- _.._- FILL .~,~-~-_.---~--" f---.------_...-,.--~._-._.- e----...-- '\:-~~--_.--~-.-_._---~~_._. -..:>-----_.,.-..-._-- EL.890'._----~--....~-_.- --"----- 900 800 1200 1600 ~1300 zo ~1100 >w;j 1000 1500 Iii 1400 lL HIGH LEVEL SUSITNA SCALE C RIVER BRIDGE HIGH TYPICAL CROSS LEVEL SUSITNA SECTION RIVER BRIDGE;, SCALE D PLATE F 34 4 (I INCH·4 MILES) MAIN ACCESS ROAD CONSTRUCTION ROAD PERMANENT SITE ROAD UTILIDOR SCALE: 0"':~~!iiiiiiiiiiiiii~8 MILES-! SCALE:?1000 2000 FEET ! (liNCH·1000 FEET) WATANA PROJECT GENERAL LAYOUT SITE FACILITI ES -~-j 2-345 KV ~~ANSMISSION LINES GOLD CREEK LEGEND EXHIBIT F liil ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC 0'oo-nv't--! wi § <f'~: W i 0'01 §1s 8' , e: 81 <0,cJ· ....' Q.I -tf): 0' f"--i gi Q.I 0 WI ....,~i 0'1J5, 1 w r-.v ! W; ....' '" !~~i!21 wi I I N 3.226.000 N 3.228.000 N3 34 N 3 30 N3 N 3 32000 I !/j_~"""'~~~~;=~_lf;~~W~c::e>.~~J_~M:A~:rI ~E~R I AL i SOLID WAS"!",/:1"OURCE I LANDFILL 'f III..:~[~~¥ETR'E"A'iM-EN'-~l'"'--J-f-+--_I ,---f-TI~ --"~~QQ!;~~_t~~~~f-_h~::~~L~g:~MM~PTRUCTIO~ PLATE F 35 4 MAIN ACCESS ROAD CONSTRUCTION ROAD PERMANENT SITE ROAD HAUL ROAD RUNOUT SCALE:~1000 2000 FEET -! (I INCH =1000 FEET) SCALE:O~~~iiiiiiiiiiiiii~8 MILESi_! (I INCH.4 MILES) ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT EXHiBIT F WATANA GENERAL LAYOUT CONSTRUCTION AND HAUL ROADS I I ---;~ I I I -------1-- I ! WATANA DAM I I -+---~­ I =-t~==~~==1~-):f-~~t;:~~~~L~d::?r:f$>/'IfP/ \&~ 11~ J~\fI$J ~.-/.~/~rt~~REe.AGGREGATE...~7 SOURCE ~~r::::::--'--b=--~::""-.,~ ZCONSTRUCTION HAUL ROAD FOR AREA - E EXTENDS 5 MILES DOWN RIVER §~j ~I UJ N3 N 34 N 3,230.000 N 3.232,QQQ o 200 400 FEET i i (I INCH.200 FEET) SCALE ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT LEGEND (0 BASEBALL ®SOFTBALLoSECURITYoHOSPITAL ®FIRE e OIL SPILL ®CAMP MANAGER'S OFFICE CD SOILS LAB ®PARKING AREAS ®ADMINISTRATION OFFICES @ STORE ®BUS SHELTERS ®DORMITORIES @ LAUNDRY @ COMMUNICATIONS CTR. ®BANK ®RECREATION HALL @ KITCHEN El DINING ®FOOD SERVICE WAREHOUSE @ WAREHOUSE @ GYMNASIUM @ SWIMMING POOL @ MAINTENANCE GARAGE @ PUMP HOUSE (WATER) @ HOCKEY RINK @ BACHELOR DORMS MGMT"TYPE A @ BACHELOR DORMS MGMT.TYPE B @ 10'PERMAWALK I@>16'PERMAWALK @ MANAGER'S GUEST HOUSE ,@ OWNER'S GUEST HOUSE ®CONTRACTOR'S GUEST HOUSE ®STAFF CLUBHOUSE @ GENERATING STATION ~RELOCATED CAMP HOUSING (160 SPACES) @ FOOTBALL FIELD @ FUEL STORAGE TANK @ WATER RESERVOIR @ UTILIDOR @ HELIPAD WATANA MAIN CONSTRUCTION CAMP SITE i --"--~N3,23B.OOO ~25 \ \ SEWAGE (( TREATMENT PLANT _.--"-)-~- 'C-01'' [756,000 FENCE --T-- ~ -,..-,- 2375 C~ £755,000E753,OOO t:::::::J t:::::::J ~t:::::::J r::=:=:I c:::::::::r @ t:::::::J TYP.t:::::::J t:::::::J ~c:::::::::r c:::::::::rtrX__X_~t:::::::J t:::::::J g:fY·0 ~r t:::::::J t:::::::J D-®cfI1~lIDJ TYP. ~--~----cs::-<2)-------TO MAIN 3 ~~\o-@ACCESS @ §ROAD 39 '".,,1~ EXHIBIT F PLATE F36 PLATE F 37 PERMANENT MULTIFAMILY DWELLINGS 72 UNITS FURNISHED BY YEAR 1992 16 UNITS 2001 PERMANENT SINGLE FAMILY DWELLINGS 21 UNITS FURNISHED BY YEAR 1992 6 UNITS " 2001 PERMANENT HOSPITAL TEMPORARY HOUSING /UTILITIES FURNISHED BY OWNER 16 EA.-4 BEDROOMS UNITS 28'x 50' 16 EA.-2 "24'x 50' 16EA.-3 72 EA.-2 14'x 60' 200EA.-3 14'x60' TEMPORARY LOTS/UTILITIES FURNISHED BY OWNER 240 EA.-LOT SPACES PARKING AREAS MANAGER'S OFFICES GENERATING STATION FIRE STATION GAS STATION SCHOOL SWIMMING POOL GYMNASIUM STORE RECREATION CENTER SEWAGE COLLECTION PUMP STATION WATER PUMP STATION UTILIDOR SEWAGE TREATMENT PLANT WATER TREATMENT PLANT FUEL STORAGE TANK (50,000 g) SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY 200 Cd CD ® ® @ ® ®o @ ® @ @ @ ® @ @ []J]J LEGEND o PERMANENT NON-RESIDENTIAL BLDG. ~PERMANENT ROAD WATANA VILLAGE AND TOWN SITE EXHIBIT F o 400 FEET SCALE ~I~~oi3i:iiiiii_~!(I INCH =200 FEET) /~o 'Ii 2300 ------+N3,232,000-- c ---------------7'<::--.---1----r"?r------tl3,233,ooO !J~--""-l'\/-r-~~ !~"-)~-~ .E 748,000 E749,ooO E747,OOO I I E746,OOOE745,OOOE744,OOO ,..'.Di ..,j·,<. \,.;'-'. PERMANENT VILLAGE HOUSING '", 'o GRANULAR PAD HEATER 1 ,-I'---+--I---T-----'<:-'--i.--r:::-,T~REATED WOOD SUPPORTS AS REOUIRED~+,."..,..,.---f,-;.....,.,-M------\--~~~ INSULATION MAINTENANCE ROOM 13.5' TYPICAL DORM TWO MAN SLEEPING ROOMS (2 STORY, 8 MODULES PER STORY) SCALE'B DETAIL I I'224.0'"If0 tD MODULE II MODULE I: MODULE II MODULE II ~I ~0 r '""",~O ~II )II II i~'"MODULE MODULE MODULE WASH ROOM '" /' ,J PERMAWALK ~(SEE TYPICAL SECTION) DETAIL I TYPICAL DORMITORY MODULE SCALE: C TYPICAL PERMAWALK WITH UTILIDOR (AT DORMS) 50.0'SCALE:D 2.5 I~ 2 %SLOPE 17.0' ""\"''''::'~9"BASE-2"GRADE A B.O' GRANULAR PAD : 17.0' 2%SLOPE TYPICAL SECTION -PERMANENT SITE ROAD SCALE:C ,.0'·" dl 4" CRUSHED 2.5 ~~ BEDROOMBEDROOM BATH KITCHEN PLATE F 3B SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY EXHIBIT F WATANA AND DEVIL CANYON CONSTRUCTION CAMP DETAILS TYPICAL SECTION - SECONDARY SITE ROAP SCALE'C 0 2 4 FEET SCALE D i ,(1/2 INCH: I FEET) 0 5 10 FEET SCALE C I ,(I INCH:5 FEET) 0 20 40 FEET SCALE B i ,(liNCH:20 FEET) 0 10 20 FEET SCALE A i ,(liNCH:10 FEET) 2"INSULATION 6"MASON RY WALL 3"SCULPTURED PANELS SECTION A-A SCALE'A 6"CONCRETE SLAB 2" INSULATION 12 --e~~~~-;;;::::l3 RIGID FRAME 'ISLAB SOILS AND CONCRETE LABORATORY I+A STORAGE TY~CAL WOOD FRAME MODULAR HOUSE FOUR BEDROOM FAMILY UNIT SCALE:C TYPICAL STEEL FRAME BUILDING SOILS AND CONCRETE LABORATORY SCALE:A STEPS OFFICE 2 OFFICE 3 OFFICE I" DEVIL CANYON RESERVOIR )-, \ I ') ) i (I INCH =4 MILES) o 4 B MILES ISCALELOCATIONMAP LEGEND --------NORMAL MAXIMUM OPERATING LEVEL EL. 1455 -----2000~CONTOUR IN FEET ABOVE MSL ( I INCH =I MILE) o 2 MILES 2;SCALE DEVI L CANYON RESERVOIR PLAN ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT / -, / PLAN \ -, 0••_____ \ \ \ WATANA DAM EXHIBIT F PLATE F39 N3.226,ooo------------f----\--- PLATE F40 ( I INCH =400 FEET) DEVIL CANYON SITE LAYOUT SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY 400 800 FEET ==::J EXHIBIT F .1---------------1 o SCALE j~""",,~~;;;;;i;i -~1700-r.~~'\}2-45 KV TRANSMISSION-.j.----I __LINES TO GOLD CREEK -.L~=--:-J- \ I! :\ "..'..~:)i\\!\V \I I 2100~ \ PLATE F41 (I INCH =200 FEET) ALASKA POWER AUTHORITY 200 EXHIBIT F / 1600 DEVIL CANYON GENERAL ARRANGEMENT SUSITNA HYDROELECTRIC PROJECT ooo,,; (lj w o 400 FEET SCALE ~i1lllillli1lllillli~~;;;;;;;;;1 1550 oo ~ (lj ur E ERGENCY SPILLWA § .0 iiiur o 8,.: (lj w 8 ~ (lj ur ~... NORMAL MAXIMUM RESERVOIR LEVEL EL.1455 ~ N 3,221,000 --b~====-==-~---=:o"~q--""==:'---\-~'--~-T'--\:---\,",,,---j----="7-:~~ N3,222,ooo ------l~+i\------+--f_--_j'----:T_-----~ct-~-""'" <, <, <:-, 0\\0f2III_ \CD (\'\ PLAN ooo ~ "'z NORMAL MAXIMUM RESERVOIR LEVEL EL.14 5 1600 1500 1400 1300 t;;1200 wu, ~ :z 11000 ~>~w 1000 900 800 700 ~- r---...---.....--------\,EMERGENCY SPILLWAY ./',,-r THRUST BLOCK ;-TOP OF PARAPET EL.l466 rTHRUST BLOCK FUSE PLUG _----r'~SADDLE OAM CREST EL.l472 AT CENTER<,<,I I r:ARCH OAM CREST EL.l463 /EL.1470 ,EL.l470 ::::-1:-tL.i465:5 I \"'-~--I .-/~~\EL.1434 1 .i/lll;;ilil \ """'''''''''''''''-;'~~~_~ORIGINAL GROUND -~~;ILTO GROUTJJ,---..'.:;t SURFACE w::------~GALLERIES //"',/ ~~,/OAM FOUNDATION //1/"~~~/~1IJ '~",.>~ill ••.~~75 0 100 200 FEET I Ii)SCALE i !( I INCH •100 FEET) 4 6 ~,..,.,= ~Q-!'/_4-...~)(Q~! ACCESS""'"""""~·IIOQ.O_ :TO OISCHARGE VALVES L".\ 3 I 2/,.~-!ALASKA POWER AUTHORITYOUTLET'~9~Q-g-m-[;k 1/'--+FACILITIES U SUSITNA HYOROELECTRIC PROJECT ~.'----'--~./DEVIL CANYON DAMS"''----.-/PLAN AND PROFILE EXHIBIT F I PLATE F42 PROF ILE (DEVELOPED -LOOKING UPSTREAM) 60 PLATE F43 504030 50 DEVIL CANYON MAIN DAM GEOMETRY SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY CENTRAL ANGLE (DEGS) EXHIBIT F 2010 ~-RIGHT EXTRADOS ~-LEFT EXTRADOS O~~~~iiiiiiiiiiiiiil~OiO FEETSCALEI:!(liNCH'50 FEET) NOTE CONTOUR LINES SHOW SOUND ROCK LEGEND DIAGRAM OF CENTRAL ANGLES 1500 1400 1300 I-ww 1200LL !': z 0 i=~1100w ..J W 1000 900 820 ,,,:>00 0 0 !if 0 <J> I "0 %00 \ \ \ I 0'"~ 0 !;;.\'"0ro00 0 0 0 '\0 Q g f.:!'"I 'b PLANE \) PLAN OF ARCH 8 Q o ! (8s: / LEGEND EL.2020.32 CENTER R 1: I-~INTRADOS FACEtL LEFT SIDE RADIUS E--EXTRADOS FACE~R-RIGHT SIDE L_-RADIUS L CENTER OF INTRADOS CROWN SECTION 50 SCALE EL.820 EL.777.61 CENTER OF EXTRADOS-CROWN SECTION EL.1037.83 T::.804.22 RR AXIS =777.19'(N.T.S.l EL.1240 EL. 1100 R L AXIS =699.67'(N.T.S.) EL.1463~----+--~--'----:.:~7-----20' 20' 26.96' 1400 1300 900 800 1500 1000 zo ~>'"iiJ 1100 l;j 1200 '"IL Z 662.79' 812.36' ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT DEVIL CANYON MAIN DAM CROWN SECTION EXHIBIT F PLATE F44 PLANE AXIS OF DAM SOUND ROCK i PLAN AT""Ei:820 I I PLAN AT EL.900 I REFERENCEr--OF DAM C "'Dti'fO ~<:', W fO ~C ~D \>- I ~<:' ~ PLAN Ai'EL.i'463\>-ft/I /~ PL'AN AT EL.l300 I, REFERENCE PLANE1OF DAM , \) <, PLAN AT""'E'L.'iiOo SECTION E-E 0 0 FEET)(I INCH'I WER AUTHORITY ALASKA PO ECTRIC PROJECT SUSITNA HYDR~~YON DEVIL C AM MAIN D SECTIONS 100 SCALE SECTIOI\N'--..!::....,::__ DAM SECTIONS (PARAPET NOT SHOWN) SECTION C-C SECTION B-B ORIGINAL GROUND SURFACE (TYP.) SECTION A-A 900 1100 1000 1500 1400 f- W W u, ~ Zo j:::; W..J W LINE OF EXCAVATION OUTLET FACILITIES TOP OF SOUND ROCK DAM PROFILE ---------CC~RE~S~T~E~l.=.1~4~633~===--------_----::1=-'1<- 1500 f- W ~1200 ~ z 0 ~1100>W ..J W 1000 900 800 EXHIBIT F PLATE F45 1463 1370 lZB5............ 1200 z: !? ... 1100..>... ..J... 1000 900 620 LOAD COMBINATION ULI SELF WEIGHT.HYOROSTATIC r------i-------Jr--'r---i-----i---T---i-----Jr----i--~-_,1463 1370 1285 1200 1100 1000 900 -n_"---'----'---........----'--......--'----'8 20 900 1000 1200 1100 1285 1370 i----r---i---i--~--,1463~.!O-,f:--,!o-r-r-l-O 0 ~J~~4__!1ll.L2_I !l__I"I1 I_I,6 I.!'l__J2 I.2__.!~5__L~h -141 -1 1 -~O 18 I6 15 615 r ~2 !4 -29 86 156 '\0 2!3 266 15 I 0 Ii.1.0 It 2 I 2t6 ,,1 3 /~~~--ff----'j i o--j"O--Z'---jh--I"'r--$7---iii-=~:~"~h J8 2.17 ILL~~t __3_t__~~~/ 123~IJ~2 7 31 3~10 2'5 1'~76 /54 .77 2 2 2 4 I 7 2lo Jo 2 I~~.3 6 41 7 517 3J--7266 /18~~2 6 318 2 I 39 2 19 256----"------~jG 497 4 12 5.1 5 4 7/4 38 "'-I 5 1 6 3I!HI---4 ~II 541 'IF 533 I '\,i!3 269 LOAD COMBINATION UL3 SELF WEIGHT ..HYDROSTATIC"TEMPERATURE 1463 1370 1265............ 1200 ~ z S'1100t-..>... ..J... 1000 '00 820 669..e 8 '"0 '":I;'""'...~'"'"'"'"'",,;,.;0 ,,j 2 t-'.,.;.-i...'""'0 a '"0!!'!.!2 ~'"co ,.:,.:,.:,.:,.:,.:I-'Iii ,.:...ttl on II>'"'"'"'" PLATEF45 A ALASKA POWER AUTHORITY SUSITNA HYOROELECTRIC PROJECT EXHIBIT F DEVIL CANYON ARCH DAM STRESSES RESERVOIR AT EL.1455 - - I 463 LEGEND (MINUS)INDICATES 'lSION -I370 &..-SHEAR STRESS IN PS.1.WHERE SHOWN 5 o" ~STRESS AT UPSTREAM OR EXTRADOS FACE -I285 6r8'-~STRESS AT DOWNSTREAM OR INTRADOS FACE -I200 -I 100 o 0o 1 I '"'"t-'"'"""'"t- 8 .,ui '"0 N ...t-O>'"'",.:,.:,.:,.:CIl CIl CIl CIl o -I 0 -I I 2 8 o -I 7 oo -47 5fl9 ooo -I 2>6 o CANTILEVER STRESSES (PARALLEL TO T1iE F.6;CE OF THE DAM LOOKING UPSTREAM) o I ELI o I LOAD COMBINATION st:LF WEIGHT ..HYDROSTATIC"DYNAMIC (UPSTREAM GROUND MOTION I ..8 ~g '"to :1\m '"....0" t-!.":'"'".......,.;~..:g oJ ,.:.,;.-i g .,;...-i..g 0 '"III 0Ii52 g N ..!.!2 =.,.,...0>'"~Iii ti ,.:,.:,.:,.:,.:t;;,.:,.:,.:,.:on '"to II>on on on on on ARCH STRESSES (PARALLEL TO THE FACE OF THE DAM LOOKING UPSTREAM) 1463 1370 91 3 1285 .........1200... '!!: lS 1100 ;::..>... ..J...1000 !loo 820 --"_.._--- 3 0 :I 0 0 0 0 0 3 0 :I 0 0 00 00 20 LEGEND -(MINUS)INDICATES TENSION 500""---SHEAR STIIESS It P.$I.WHERE SHOWN --45-STRESS AT UPSTREAM OR EXTRADOS ~ 658 I '--STRESS AT DOWNSTREAM OR INTRAD~B.CE I ALASKA POWER AUTHORITY I SUSITNA HYDROELECTRIC PROJECT DEVIL CANYON ARCH DAM STRESSES RESERVOIR AT EL. 1405 EXHIBIT F I PLATEf45 B 00 90 82 20 10 46 - 110 - 120 -128 - 137 -10 -9 I 8 .....on..... I- III o a I a a a I a a I o D I a a a o a 292 a a a I a a a I a a I CANTILEVER STRESSES (PARALLEL TO THE FACE OF THE DAM LOOKING UPSTREAM) a o I a I o I 10 I 7 I a II 7 a I a 5 1 1 5 I 6 -I ~-I """: 6 Z 3 Z I Z 6 J •5 27 / 2 4 2 a 1 4 1 8 9 115 1 8 244 I 2 Z 1 0 r 2 7 4 -I -17 I 15 I 2 J:3 -3Z "'"I 7 276 I 2 110 5 II~2 5 5/ ':~""r "3-3 ~"'bJ'/3 -I 4 24 23 18 7 16 29 14 -Ir:j ~I--:~---~6---47--2 4/13i N UL2 5 2~2 -I TATIC m"",T---6 ~r/39; ~,9 41 l.:- 515 4 /524 I I I ""~~,~I I I 1 1 I SELF WEIGHT +HYDRaS LOAD COMBINATION UL4 LOAD COMBINATIO SELF WEIGHT.HYDROSTATIC.TEMPERATURE ARCH STRESSES «PARALLEL TO THE FACE OJ'THE DAM LOOKING UPSTREAM) 215 ;!:...8 :l:0 III '":ll Oi '"'".....;!::!:0 '"0 .,'"'"OJ '"'".. '"~on ..........0 '"~on '"'"........ ,.;a ..0 N '"'"on 8 8 '"on ,.;8 ..o OJ '"'"oi on 0 cO '"..0 '"..0 0 '".,0 OJ ....en '"0 e '"co s 0 0 OJ ~!!!!!2 !l!e .,.,..'"on ...~~!!2 ~=2 ........................I-'"I-'......I-......I-.........I-'l-I-I-'............ Ul Ul Ul III III Ul OJ III Ul III Ul III Ul Ul III Ul III II>Ul III III Ul III II>VI -187 -195 -96 -14 8Z0 900 IZ85 1463 1370 1463 1370 IZ85 I- ::lIZOO... i!; z 0 1100;:..:> lU ..J lU 1000· 900 8Z0 \;;IZOO ~ i!: ~1100 ~ lU ..J lU 1000 A 20'ACCESS SHAFT &+B !EL.1380 7 , '!EL.1380 7, --- &+C ~L.1410 ot SADDLE DAM SUMMARYOF STABILITY ANALYSES FACTORS OF SAFETY DEVIL CANYON ARCH DAM THRUST BLOCK ABUTMENTS a+E ROADWAY 20'DAM ~ST-- ~LEFT RIGHT -,E -,B LOAD CONOlTION SLIDING SHEAR FLOATATION SLIDING SHEAR FRICTrON FLOATATION"I+c FRICTION PLAN AT EL.1466<,,NORMAL '~TOE OF SADDLE DAM NO ICE 14.11.4.64 6.37 N.A.6.87 6.16 P LAN AT EL. 1472 EXTREME EARTHQUAKE N.A.1.04 6.-US N.A.1.96 6.31 (0,8 SEE) PARAPET PHYSICAL PARAMETERS PLATE F46 (I INCH'30 FEET) 30 60 FEET EXHIBIT F SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY DEVIL CANYON MAIN DAM THRUST BLOCKS o i TOP OF PARAPET EL.14 SCALE "- .........................ARCH DAM",-"-, ..."-GROUTING/DRAINAGE GALLERY EL.1466:0::01 I I I 1 I I I I I I I I I I I I I I I I I I I I J 30'ROAD AND VERGE EL 1463 0 , I I I I I I I I I I : I I I J SECTION 0-0 THflUST GROUTING/DRAINAGE GALLERY EL.1365 PARAPET EL.1466 NORMAL MAXIMUM OPERATING LEVEL EL.1455...-- 4>=31.6 0 I 4>=31.6 0 e =200 PSI e =100 PSI '--;==""i"F=n----r,---.:r~=::..--71r_--...""'l'.....=~=:;:;;;:;;;;=;;:::=========~.EL.145:S OUTLINE OF SADDLE DAM CORE \ f DAMI'""""'OC' 50' EL.1410 SADDLE DAM IMPERVIOUS CORE 176' 200' SECTION A-A I I I I I I I I I I -_...J I I:': I I I I .Ly-L I I I I I 1 I I I_L_~~_~_-=~~ I I r GROUTING AND DRAINAGE GALLERY I.I EL.1466 PARAPET SECTION B-B SECTION C-C SECTION E-E LEFT ABUTMENT THRUST BLOCK RIGHT .ABUTMENT THRUST BLOCK SADDLE DAM CREST EL.l472 S?~CONCRETE SLAB -DRAINAGE CHANNEL IT # III~DRAINAGE #HOLES II II 1'10. II ..II-~,DRAINAGEr-HOLES II II EMERGENCY SPILLWAY GROUT HOLES ZONE OF CONSOLIDATION GROUTING 30'DEPTH -"D in !::: TOP OF ROCK SCALE A PR 0 FILE (LOOKING UPSTREAM) LIMIT OF GROUT CURTAIN 1-1-1-1-1-1-1-1-1_1';. ACCESS SHAFT TO OUTLET FACILITIES ---- - --- "D THRUST BLOCK DEVELOPED GALLERY WITHIN THRUST BLOCK ORIGINAL GROUND SURFACE EXCAVATION LINE ,,-20'H x 15'W ACCESS /GALLERIES ARCH DAM CREST EL.1463 \. 16 0 0 ~-:. 1500 SPILLWAY ------F NOT SHOWN I 1400 1300 1200 1100 f-1000 wwu, E': z 900 0 ~>W ...J BOOur 700 GALLERY DETAIL SCALE B SECTION C-C SCALE A PLATE F47 5 100 SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY EXHIBIT F DEVI L CANYON MAIN DAM GROUTING AND DRAINAGE o 10 FEET SCALE B ~i~~~iiiiiiiiiiiiiiiiiiiii~"(I INCH.5 FEET) o 200 FEET SCALE A i I (I INCH=100 FEET I SECTION D-D SCALE A ORIGINAL -,NORMAL MAXIMUM GROUND OPERATINGLEVEL SURFACE ~E:1455 TOPOFROCK~ 24 ,~I~ r:DRAINAGE GALLERY WITHIN DAM 100' o CURTAIN GROUTING TOP OF J SOUND ROCK GROUTING a DRAINAGE GALLERIES IJI GROUT , \ '..DRAINAGE CURTAIN I (r--HOLES I I \ >I \ ')I \ l:.\ \ SECTION B-B SCALE A TRANSFER TROllEY HEATING JACKET 90'DIA. FIXED CONE VALVE AT El.930 (I02'DIA.FIXED CONE VALVE AT EL.1000) l B TROllEY RAil DETAIL I SCALE 8 90"DIA.STEEL LINER AT El.930 (1,283) 102"DIA.STEEL LINER AT EL.1050 (4,5,6 a 7) ----.I.--ttHtt-- El.922.5 EL.1042.5 GATE AND TRASH RACK GUIDE BULKHEAD GATE CONCRETE GUIDE PLUG f B TRASHRACK CENTER POINT OF OUTLET 2 ALIGNMENT ""=DAM REFERENCE PLANE -CENTER POINT OF OUTLET I 83 ALIGNMENTS 930 CREST OF ARCH DAM PLAN AT EL.930 SCALE A CENTER POINT OF OUTLET 4 8 6 ALIGNMENTS 1050~ 5 1 CENTER POINT OF OUTLET ___-.-"-5 8 7 A~N..~TS r car sr or "'"'" / / ----........--.., ---------1050 .: PLAN AT EL.1050 SCALE A DAM REFERENCE PlA~=E__+-~,r_-------. SECTION B-B SCA lE B PLATE F48 ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT EXHIBIT F DEVIL CANYON MAIN DAM OUTLET FACILITIES o 16 32 FEET SCALE B io'C..........""'.:.;;;;;;;]__(1/ 16INCH c I FEET) o 100 200 FEET SCALE A E :=:7 (I INCH =100 FEETl LINE OF EXCAVATION CREST EL.1463 EL.930 ORIGINAL GROUND SURFACE EL.1050 1500 1400 1300 f- ww 1200u, ;;: z 0 ~1100 w ...J W 1000 900 800 M081lE GANTRY CRANE ~ROADWAY II ' SUPPORTS /I I f;l I @ c--EL.l050_:::::::':: /DETAIL I 0 K(~El.930 ~T.W.L.EL. 8950- ,7 ,,,-'"'''' EL.820 /I"-'''1\10I 100 1400 80 1500 90 1300 f-ww u,1200 z zo ~1100 w ...J W SECTION A-A(TYPICALl SCA lE A DAM PROFILE (PROJECTION-lOOKING UPSTREAM) SCALE A DETAIL I PLATE F 50 1480 1450 1420 1390 I-ORIGINAL w GROUNDw ----------- SURFACELL1360 ~------------- z 0 f=""1330>w -lw 1300 1270 1240 1210 CHANGEOF SLOPE AT EL.1400 FINE FILTER ----' RIPRAP CHANGEOF SLOPE AT EL.1400 PROCESSEDlROCKFILL __"--"-" TOP OF SOUNDROCK -------- SECTION THROUGH SADDLE DAM AT MAXIMUM HEIGHT 30o 60 FEET SCALE ~i~~~~iiiiiii~!·(liNCH =30 FEET! ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT DEVIL CANYON SADDLE DAM SECTION EXHIBIT F PLATE F49 1600 1500 I- UI UI u.1400 a; z 0;::1300~ UI -'UI 1200 1100 SLOPE 400' DAM CREST SLOPE EXCAVATION LINE (TOP OF SOUND ROCK) PRO F IL E (LOOKING UPSTREAM) SCALE A DAM CREST NOMINAL CREST ~+--=-,__~El9 _ EMERGENCY SPILLWAY PROFILE SHOWING CREST ELEVATIONS N.T,S. ::E« (/)0 Xu.«0 EL.1472 SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY PLATE F50 100 20 DEVIL CANYON SADDLE DAM PROFILE AND DETAIL EXHIBIT F o 40 FEET SCALE B ~i1IIIIII1IIIIII!5;'_~!(I INCH =20 FEET) o 200 FEET SCALE A i i (liNCH =100 FEET) EL.1400 3'OVERBUILD FOR SEISMIC SETTLEMENT- SEE PROFILE DETAIL ,ROCKFILL-.! 3'ROAD BASE SLOPE VARIES NOMINAL PROFILE OF DAM '-PROCESSED ROCKFILL \ 10.0' EL.1434 NORMAL MAXIMUM OPERATING LEVEL EL.1455 DET AIL I SCALE B (PLATE F49) ...~ 950 o Q~'-~--~- <J) w ~115A-+--"'--~--- ~::::=~~:::'900 ~~:c-:c-~:-"'o/~~~,c"_:---"-~~~ 1250~ \20 115 ooo... <J) w ACCESS ROAD DIVERS ION INTAKE --t-I-~-:1~~~t~s;;;;STRUCTURE INTAKE PORTAL N3223000 PLAN SCALE A PLATE F51 100 ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT DEVIL CANYON DIVERSION GENERAL ARRANGEMENT EXHIBIT F o 200 FEET SCALE A ~i~~~~iiiiiii~~J (I INCH =100 FEET) PROFILE AT CENTERLINE TUNNEL SCALE A ROCK TOE TO 8E REMOVED AFTER CONSTRUCTION OF TUNNEL ,~------... /-. ------------L:ORIGINAL GROUND /'\SURFACE ~"-~----:-./ \OP OF ROCK ___.>:<,""VTOP OF ROCK '-J;'<, // FOR DETAILS~\-1/~4 / n~~~n~~L~53SEEPLATEF53 \V· INTAKE STRUCTURE-\\f~~'L rcOUTLET STRUCTURE MAX WATER EL,944 .~4[j EL.947 t 8END rCONC.LrED -~I /~~gC~ET~~MOVED AFTER i-:I;, / TUNNEL FLOW t 8END CONSTRUCTION OFITUNNEL -EL.890 -----/~L.870l1 I ,~,,~,,~--\ "-",\; .EL.898 MAX. WATER EL.895 A~\:-.'F !SLOPE 0,66%,[~-:t !111 ,''1--..-EL,860 '",,''''''''''''<0 'f'b1'tJ' '''''--CONCRETE 1113IElI I -,;{Ilall;;j" PLUG ~.,,I ,,, \0+00 5+00 10.00 15.00 STATIONING IN FEET 1400 1300 1200 f-w w U-1100 ~ ze I-1000c(>w -'w 900 800 11---I ----------~------j MAIN DAM EXCAVATION SLOPE AS REQUIRED ----..---,,--- EL915 -~-----------------------------------1 BERM AS REQUIRED 2 <::::ll ,---------ROCK OR GRAVEL FILL 30' CORE --, FINE FILTER ~~ CLOSURE DAM 5'RIPRAP COARSE FILTER,',,: ~';~*""T""T""", ROCKORGRAVEL --- FILL MAXIMUM WATER E~944 TOP OF ROCK~'r8"1T§1i§r "--" 960 930 .... UJ UJu,900 ~ z 0;: :i!B70 UJ ..J UJ B40 BIO TYPICAL CROSS SECTION (PLATE F 51) UPSTREAM COFFERDAM MAXIMUM WATER ----ROCKOR GRAVEL FILL ____<"P.':RQ!!l. ---70'MAXIMUM DEPTH APPROX. ,----~5'RIPRAP BO' 2 11/ BERM AS REQUIRED ..-.. ROCKOR GRAVEL \ .--F_IL_L_\----j~=;=;==;=;;::::,:=;=;=;:;:::!;z==~~~T-----~~L-'-'-=----1900 B70 .... UJ UJ u,B40~ z 0 -"~,.S>BIO UJ ..J UJ 7BO 750 TYPICAL CROSS SECTION (PLATE F51) DOWNSTREAM COFFERDAM 300~""",,~~__~6'0 FEETSCALEi:!(1INCH=30FEET) ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT DEVIL CANYON DIVERSION COFFERDAM SECTIONS EXHIBIT F PLATE F52 PLATE F53 SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY DEVIL CANYON DIVERSION SECTIONS 20 40 FEET !(liNCH =20 FEET) EXHIBIT F iiJl------------I o 10 20 FEET SCAI F C EI~~~~_~I (I INCH=10 FEET) o SCALE 8 I o 16 32 FEET SCALE A EI~~5~_iiiiii!(liNCH"\6 FEET) c i ,.-1.5'MIN,<TYPl / EL.860 3' EL.855 EL. B98 STOP LOG GUIDE STOP LOG GUIDE r- ~TUNNEL SECTION C-C SCALE A PLAN AT ELEVATION 898 SCALE A DIVERSION OUTLET STRUCTURE (PLATE F51 l 1-,01l!'i,1 FLOW'-- t- C t HOLES FOR CONTACT GROUiING·, ---'- GROUT1NG GALLERY .1 I I i" I I COVERED GATE HOIST GALLERY II I' 'I I "I I 1 tINTAKE I SECTION THRU PLUG SCALE B ELEVATION B-B SCALE A 11 ....,L--+----"..+I11+~_+----"'rl~-GATE GUIDES I,I II I II I' r II II II "~IOIII,II I' "'I II I' " ,II I ,II I ,I I,II II I, 1 I IL-.. i :/\j(/'I f1,1\/I!I'~ I //\I III /i\\', I,':' I 1/,'i'EL.870,II",11I'e'I~,I 1---+---i---' 10 EXISTING CO~C)l/ LINING / /70.0' ,I STAIR TOWER ~ SECTION A-A SCALE A PLAN AT ELEVATION 947 SCALE A "8 SEAL FACE DIVERSION INTAKE STRUCTURE (PLATE F51) ~~ I ~'r;EL.984 4U .:FIXED WHEEL ~.~GATE ~. EL.S44 EL.947 / :~l If ~AIR VENTS II II 10III II I II L.EL.910 II J II Il~ EL.900 1111, ,~-,,~~g~~~L~~~\,-, 'IO':.!;4'_OIi'-. I . 1EL.870 """"""""'"EL.864 111'qJ1i''?'111 fll!='lll~I =, 16'-0"POST TENSIONED ANCHORS So SLEEVES FOR"8 CONSOLIDATION GROUTING So PRESSURE RELIEF ~OLES IN WALLS AND INVERT SEALING FACE 24'-0"60~0" !EL.870/ FLOW-- NORM. W. MAX. W.L.... FLOW-- TYPICAL TUNNEL SECTIONS SCALE C ARCH DAM --4-.1 \ \ I I --------./)r--... // // --~---/ ---~~r--~-"--/_---- \ PLATE F54 SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY 100 DEVIL CANYON MAIN SPILLWAY GENERAL ARRANGEMENT EXHIBIT F a 200 FEET SCALE ~11IIIIIIIII1IIIIIIIII~iiiiiiiiiiiiii~(I INCH·100 FEET) NOTE: FOR SECTIONS SEE PLATE F56 15 +0010+00 STATIONING IN FEET 5+00 I /-CONTROL 13GATESV~56'(H)x30'(W)STRUCTURE "FORDETAILS SEE PLATE F p5 NORMAL MAXIMUM OPERATING ~'--~~14!55 .......- -e-»:rtERATION /-EL.1404 --------.>-,GALLERY ,EL.1375 HYO r'J~.:1611 ",;""me,1 /''11'--"'I~~~~"".i..I"-, /GROU11~VI \'~~.>:MAIN SPILLWAY/CURTAIN \L DRAINAGE '",,',1// I \GALLERY " <, <; RELIEF -.-I \I~~~'/-ORIGINAL GROUND3'MIN .~"SURFACE V FLI P BUCKET DRAIN CONC.LINER .~;.-~'(NORTH SIDE) / FOR DETAILS SEE PLATE F 56 l'>.:-e ~-"<, ~INAGEH /-~<;'-,r ORIGINAL GROUNDLES!f/i!;;:-',SURFACETO BOX DRt IN.','EL 1000 (SOUTH SIDE) BOX DRAIN j--1 !EL.970 ';~-a kn,.'-><,lI->MAX. TAILWATER EL.915 (TYPICAL) DRAINAGE.! fil~'"'Y1~, GALLERY RELIEF .---''Z '''''''N -,,---,'~I~~~F1:-c-, , -c,-.::::~- ......_--- 0.00 1600 1500 1400 1300 1200 I-wwu, 1!; z 1100 0 ti>W ..J 1000w 900 800 PROFILE 'I~ I I I ----1 I I t I I I I I I___J 92'-0' ELEVATION B-B -.,. I;~.I 0:1 0 11 0 D:II!IUIUHOIST~OUSIHG U I I / \ V 1\ /\VI\ 1/ \ /\~/'-~~.?w~I 1IIIllii,/'\/1\rELECTftlCALsueSTATIOt<I I ~CONTROL I IUIUlIH4il I b!\TRUCTURE / \ InDO I /¢.ROLLWAY 1/t ROLLWAY ROLLWAY ~I..\ '. --f-- .~--;r-·.·-\l~ El.1466 7 --------- I;--71Tli§'1~;j'1'1"j::"---r_--__r-_--_--_~_-_-_--r_--_-_---j'-;_~~an\-_I-.'i I I----------------------, 46'-0" ELI3~_ EL.1375 CREST EL.1404 l A .1100'-0' DEVIL CANYON ARCH DAM SPILLWAY CONTROL STRUCTURE SUMMARY OF STABILITY ANALYSES GATE HOIST FACTORS OF SAFETY LOAD CONDITION FOUNDATION Xcg SLIDING SHEAR FLO'ATATION OVERTURNl NGSTRE,S Uf'(FT) D.S.PSI FRICTION NORMAL INCLUDES ICE 32/56 5.1 N.A.7.4 5.0 2.5 lOADS UNUSUAL DRAl"PlUeeE 16/47 9.3 N.A.6.7 2.4 1.1 __SEALING EXTREME FACE EARTHQUAKE -48/131 38.9 N.A 2.5 5.0 1.2 (0.8 SEE) ~L",1466 PHYSICAL PARAMETERS ep =31.5° c =100 PSI i I • +-------------':.::.::.-"-------_.i~I-.-------"'="------_--_ "8 f A STOPLOG GUIDES GROUT CURTAIN EL.1375 £1..1365 NORMAL MAXIMUM OPERATING LEVEL 1----- EL.1455 CONCRETE APRON TYPICAL SECTION THRU CENTERLINE 0:=ROLLWAY PLATE F1515 SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY 16 DEVIL CANYON MAIN SPILLWAy CONTROL STRUCTURE EXHIBIT F o 32 FEET SCALE ~i~~5iiiiiiiiiiiiiiiiii'ir1!(IlllS INCH'I FEET) EL 1466 80'-0' SECTION C-C MAXIMUM ING LEVEL STORAGE VAULT STOP LOG STORAGE DRAINAGEITAHllGl'lOIJTINGGALLERY ""''''''''''''',~1l1lfB"l'Q' ]~ /lII'e'll''''''''l1 NORMAL OPERAT ELI455 '''¥ GALLERY }ROLLWAY.lII!I I I !I I I I- i I?I I !!I I I I /i-0 I :- .'r--I I I!!I I I 1--I l- I I I z 0 I I ~ OHTROL .~I I 1'5Ii=CONTRACTION JOINT STRUCTURE I I I o 0 « I I f!=..:,I I i z..._/0<.>III"" I (,i~'--I I I I I ]-II0II .'1 I ROLLWAY !!I I I 0 I .'1 i II!!I I I I I 4 :.J -IC1£t.I J ~J f+-jZ "v l~----"", SECTION A-A ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT DEVI L CANYON MAIN SPILLWAY CHUTE SECTIONS I.FOR LOCATIONOF SECTIONS AND FLIP BUCKET, SEE PLATE F54 o 8 16 FEET SCALE B'!'I """"",,~_iil==a_~(liB INCH =I FEET) o 20 40 FEET SCALE A I I ( I INCH =20 FEFT 1 _£!~CK ANCHORS ----< ----( ----< ~IO SLAB ANCHORS DETAIL 2 SCALE B SCALE A SECTION B-B l'I ~-1-1-I -V -~-A - ).'",).\A A IA )A A =?'\1 A,./ROCK~-, \ I 1 /'"ANCHORS--'-----'-c~,Il<//~-DRAINAGE HOLES ~GALLERY 00'X10') <, \ _--,-=-VARIESj~I -"'". '--------- EL.1000 EL.1020 '0, 10 '" NOTE I\]1.4 ~ORIGINAL <,.:GROUND~~ACE ~ - r I III I I I IL.-DRAINAGE HOLES <,II J.III J.1 1 II TO BOX DRAINS <,"-~II II II"-"-,,-~----~----~-1 "------------- SCALE B DETAIL I I \11.4 /' /' -(/' /' -( <,-, <, <, <,-, <, <, <, <,""-"<,BOX DRAIN DRAINAGE -_/ GALLERY HOLES - VARIES SCALE A SECTION A-A <, <./ORIGINAL~GROUND '~, ~t ~ I IVARIES LOCAL SHAPING ------\ OF EXCAVATION WHERE POSSIBLE (TYP) \l1.4 -, SECTION C-C SCALE A FLI P BUCKET DETAIL SCALE A EXHIBIT F PLATE F 56 NOTE· FOR SECTIONS SEE PLATE F58 100 200 FEETo! SCALE M =100 FEET) SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY 1400~ DEVIL CANYON EMERGENCY SPI LLWAY T GENERAL ARRANGEMEN PILOT CHANNEL F 58 .~.. TOP OF ROCK NORTH SIDE ~OR I G I N A L -GROUND SURFACE NORTH SIDE PROFILE SADDLE DAM SLOPE I rn '"en ·0 oo NORMAL MAXIMUM OPERATING LEVEL EL.1455 ~1550 1600 1500 1400 ~1500 -==::=::::::-_- No '2.'2.\000 t:;1300w u, ~ z 12000;.: <I:> W -'w 1100 1000 PLATE F57EXHIBIT F 1650 1600 1550 >--1500ww LL '"z 1450 2 >--<l>W ...J 1400w 1350 ~ ORIGINAL -\I ~g~KOF\GROUND --~SURFACE --~\.' ".»-> \,CRESTOF FUSE PLUG ..l.>EL.l4655 ~-L 120'~/1 3~11.4 EL.l464._/~~~I~.,-~~-PILOT CHANNELROCKANCHORS~'\. ,,~ 220'. I I TOPyF - ORIGINAL--_----rOCKGROUND' SURFACE \______-L -- ~,..-I "~ ELEVATION VARIES EL.1434 F CRUSHED STONE . OR GRAVEL 3/4 "TO I 1/2" TYPICAL SECTION B-B (PLATE F57) SCALE A CRUSHED STONE OR GRAVEL *4 TO 3/4" 1.5' EL.1463 EL.l4655 .~FINE FILTER 6"FINE FILTER CORE 2..4Ir:;::::::: - ROAD SRIDGE CRUSHED STONE~/--""""7"---I_"'_'O_I_-'-"'-"-+..., OR GRAVEL ~4T03/4" 35' ,I ~"-----=.EL=-,..c14"'7'-'5'--+----' SECTION A-A (PLATE F57l SCALE A 1- EL. 1434 [ I~1~1fS' 1470 1460 1450 1440 >--1430ww LL :':: z 1420 0 ~ W ...J 1410w 1400 SECTION THROUGH FUSE PLUG (PLATE F57) SCALE B 10 50 ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT DEVIL CANYON EMERGENCY SPILLWAY SECTIONS o 20 FEET SCAlE B ~I~~~~_~!.(I INCH =10 FEET) o 100 FEET SCALE A i (liNCH =50 FEET) ORIGINAL \GROUND SURFACE ------'L-_ TYPICAL SECTION C-C (PLATE F57) SCALE A EXHIBIT F PLATE F58 / oo.... ------::------------ (5 o.; '" 1200 \300 IBOO PLAN Sc:iiLE'A (5 oto -----------iD1000~UJ 1100 6o '"iD UJ -_-:._----------------I::::=-:>:-;;;;-~-:::::- oo '"UJ ooo o '"UJ ____MATCHLINE N3 223 000 ooo ~,,; 00 g UJ TAILRACE PORTAL FORDETAIL SEE PLATE F67 ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT 100 200 DEVIL CANYON POWER FACILITIES GENERAL ARRANGEMENT EXHIBIT F PLATE F59 SCALE B O~IIIIIIIIIIIIIIIIIII~iiiiiiiiiiii~200 FEET (I INCH • 100 FEET) o 400 FEET SCALE A I iiiiiiid (I INCH·200 FEET) PROFILE SCALE B -----------------.,----IIORIGINAL~ GROUND ~-r'-u "SURFACE .i-_I 1 II__-I I.»>::VACCESS SHAFT III ( PROJECTED) II _____-I I II <, NORMALMAXIMUM -:CABLE~II I; OPERATING LEVEL SHAFT !IIEL.I'I55~-" 1 /EL 1466 I :VAIR VENT SHAFTI..-10-f--rNOTv:.~~I II <l ~L.1!75 .FOR DETAIL I IIL.I 61 ~"~EE PLATE F62 ~I Ii, :I II~20'ID'CONC.I II, I i II ~, II, I ,II I I II ~GROUTGALLERY7 ' I III,II I I II TRANSFORMER' POWERHOUSE'<,1~1/~GALLERY I I /II ~SURGE CHAMBER CONSTRUCTION ADITl 0 i I /,EL 908EL896 CONCRETE LINED~~r 15' LD.=EL 858 J ~TAl LRACE TUNNEL 7 EL 820 (""""""EL 817 ii .".....,,"""~lJ'~~.250' ,,-"-0 ~.t:RAFT TUBE ""'-,,,ry",CONCRETE PLUG STEEL LINED 0 80 1000 70 900 1100 1900 1800 1500 1600 1700 .....1400 UJ UJu, ~ ~1300 § UJ -' UJ 1200 20'DIA. SURGE CHAMBER ACCESS TUNNEL SURGE CHAMBER VENT -PENSTOCK CONSTRUCTION AOIT COUNTERWEIGHT ELEVATOR TAILRACE TUNNEL DETAIL I SCALE B PERMANENT ACCESS TUNNEL ACCESS SHAFT POWERHOUSE GROUTING GALLERY TRANSFORMER GALLERY PENSTOCK CONSTRUCTION ADIT PERMANENT ACCESS TUNNEL POWERHOUSE SURGE CHAMBER PLAN ScAL'E"A PERMANENT ACCESS TUNNEL 000 '!>7,.7,.0<PENSTOCK ~ PENSTOCK CONSTRUCTION ADIT ACCESS PORTAL ,~. PLATE F60EXHIBIT F SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY DEVIL CANYON POWER FACILITIES ACCESS o 8 16 FEET SCALE B ~E~~~5iiiiiiiiiiiii~!(1/8 INCH =I FEET) o 100 200 FEET SCALE A i =:2 (I INCH =100 FEET) SURGE CHAMBER ISOMETRIC SCALE A DRAINAGE CHANNEL C\l C\l o I DRAINAGE CHANNEL ~I I I L (NOT IN PENSTDCK~I CONSTRUCTION = ADIT).:I I. o. CD '" SECTION A-A SCALE B SECTION B-B SCALE B SECTION C-C SCALE B SECTION D-D SCALE B 958 ROCK SUPPORT ~I/ AS REQUIRED (TYPICAL)I I TAILRACE TUNNEL - \..\."", SURGE CHAMBER----H~-- NORMAL T.WL EL.855 DRAFT TUBE~ GATE GUIDE GATE ~""- DRAFT TUBE ---.......i'i ~ GATE GALLERY -....-..~ DRAFT TUBE\ ."", _POWERHOUSE .". 1 -ff ~TUR~NE V VDISTRIBUTOR IFt+4t V--GENERATOR L I IIII11 '''''"'1'1='1 -L __ --------j '--........-,------T---t-i rfh II u ~~--BUS GALLERY~~.=.1/1,=,11=1/1= rSTEEL LINED ,PENSTOCK ROCK SUPPORT !~. AS REQUIRED (TYP)~(CABLE SHAFT TRANSFORMERl y\"-~ GALLERY \AII!l"\'~""";;'-""'_IT-""- 50 ~ GROUTING~ GALLERY ~~ .~ \.>TRANSITION '~LENGTH .>CONC. LINED ~PENSTOCK \ 894 878 910 782 926 862 766 814 ... '"'"...846 1!! zo j: ~B30 '"..J '" 7501-------------________________________________---J SECTION A-A SCALE B c SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY DE VIL CANYON POWER FACILITIES PLAN a SECTIONS EXHIBIT F I PLATE F 61 o 16 32 FEET SCALE B i '(1/16 INCH·I FEET) o 100 200 FEET SCALE A ~i11111111IIIIII5;'iiiiiiii~'(I INCH·100 FEET) -~TRANSITION SECTION 8 ·-8 SCALE 8 878 862 ... '"wu, ~846 /z !2... <l 830>w ..Jw 814 798 o l ~~AILRACE pTUNNEL ACCESS SHAFT TRANSFORMER GALLERY 115' c PLAN SCALE A ACCESS~ TUNNEL \ GROUT:~r-r GALLERY r- PENSTOCK CONSTRUCTION ADIT -rrr p ~::rjl:=l P P PENSTOCK~ ~ "B INTAKE GANTRY CRANE il,INTAKE NO.I il,INTAKE NO.2 60'-0"t INTAKE NO.3 60'-0"INTAKE NO.4 PLATE F 62 DEVIL CANYON POWER INTAKE SECTIONS SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY 16 EXHIBIT F o 32 FEET SCALE ~;~~§iiiiiiiiiiiiiiii~!'(1/16 INCH"I FEET) AIR VENT ELEVATION a-a AIR VENT EL 1466 ~==f=====;±;;;B;;;==I==;;;;;:';m~±;';;;±;';;;"'F===*==='T"===;====*=====f=~t==F'===;;j;;;;===T=====~__ b -'cr b -'0 (\/ - t b-'(\/ -0 -'lDro 5? (\/ A "0 !-'0 (\/ -0-, (\/ AIR VENT INTAKE GATE BULKHEAD GATE GUIDE =ml'Hllf?ti!\IIISili8iU:= INTAKE GATE GUIDE BULKHEAD GATE GUIDES INTAKE GATE GUIDES SECTION A-A SEALING FACE ELI466 STRUT (TYP.) EL.1365 "0-,~ !ro '" I+B :<t FLOW ;r '0-, !!! HEATED ICE BOOM MIN. W.L. RESERVOIR EL.1405- SHUTTER GATE GUIDES TRASHRACK GUIDES ICE BOOM GUIDES NORMAL MAXIMUM CmT1riFTft====::::'lfiif""l~~-=rOil!--r~~W1i;W­OPERATING LEVEL EL.1455 PLAN AT INTAKE CENTERLINE II I IIIIII II II ~ . o --1 D OIL 0 STORAGE-O o o D MACHINE SHOP AREA 1101-0 11 tUNIT 3 I 120'-0"60'-0" (TYP) ~QII o PLAN AT EL.802.0 PLAN AT EL.817.0 PLAN AT EL.839.0 (MECHANICAL SERVICES ROOM AT DISTRIBUTOR LEVEL (DRAINAGE AND DEWATERING LEVEL) (DISTRIBUTOR LEVEL)(GENERATOR FLOOR) POWERHOUSE PLAN PLAN A'i'EL.8i7.0 HHHHHHHHHHHHHH 110'-0"N.T.S.70'-0"60'-0 "(TYP')120'-0"1101-011 UNIT 2 tUNIT 3 UNIT 4 ELEVATOREIOI FIREWALL H H H=l iI J\~NTROL D D DOMCJCJ0 0 ON =[2J I I ~I ~+ON ~ON $-=BATTERY ROOM ';',SERVICE BAY 0,-... -I{).... "'~EQUIPMENT HATCH 0~.....~1~6__,.;3~2 FEET SCALE t:==(1/16 INCH'I FEET) PLATE F63 SUSITNA HYDROELECTRIC PROJECT DEVIL CANYON POWERHOUSE PLANS ALASKA POWER AUTHORITY EXHIBIT F POWERHOUSE PLAN AT EL.858.0 EI NOT USED E2 15 KV ISOLATED PHASE BUS E3 GENERATOR TERMINAL CUBICAL E4 GENERATOR NEUTRAL CUBICAL E5 UNIT AUXILIARY SWITCHBOARD E6 RELAY BOARD E7 TURBINE - GENERATOR CONTROL BOARD EB EXCITATION BOARD E9 EXCITATION TRANSFORMER EIO MAIN AUXILIARY SWITCHGEAR E II AUXILIARY SERVICE TRANSFORMER (5/7.5 MVA)-PLATE F64 E 12 AUXILIARY SERVICE TRANSFORMER ( 2 M VA)- PLATE F64 E 13 GENERAL AUXILIARY SWITCHBOARD E 14 ESSENTIAL SERVICES SWITCHBOARD LEGEND EL.776 EL.794 "C I ,,~-EL.909 EL.891 I--~ '0 I -CD N EL.858 iJJ r"t'-Iii EL.B39 ~ELB2B r~a.817 ,~1lP'- 1fT 1fT I UNIT 4 ~ tt UNIT 3 ~ "8 ! i I UNIT 2 ~ I -'A "A UNIT I (l., l I F '" I ~I I I ~~~~~~~dlll~F===I===I~ui==~6~~~~~~~~~~~~~9=~~~~=~~=~~~~dj ,~,~n ~ '\O/II\=/L ~POWERHOUSE ACCESS I ELEVATOR II LONGITUDINAL SECTION (THRU CENTERLINE OF UNITS) DEVIL CANYON POWERHOUSE SECTIONS SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY 16o 32 FEET SCALE ~i~~5iliiiiiiiiiiiiii~"(1/16 INCH =I FEET) I I ~~I ~IUJ EL.839 EL.858 EU88 EL.794 EL.839 EL.909 AUXILIARY SERVICE TRANSFORMER '\(517.5 MVA)Lhc~_~=~~1t!--,5;---"'----70;-j---.:>L--"2;.-.:\f;L.89 I 200 TON POWERHOUSE CRANE(2) SUSPENDED CEILING _GENERATOR -+-+--PIPING ANO VENTILATION GALLERY ~Ii:::=-=---rt---<t..DISTRISUTOR TURBINE 74'-0" EL.89 I EL.909 EL.817 EL.839 EL.828 DRAINAGE AND ---Jl+:::--l DEWATERING EL.794.GALLERY EL.783"-------=~......:::o-----------___j EXHIBIT F PLATE F64 SECTION A-A (SECTION THRU CENTERLINE OF UNIT).SEC T ION B- B (SECTION THRU BUS GALLERY)SEC T ION C. C (SECTION THRU SERVICE BAY) 82'-0" ~._---_..r'T 'I~'IrRAI~S // 82'-0" ; =0_. It) '" - [SPARE \I TRANSFORMER ~OIL TANKS 0 L J I I I IL "-CABLE SHAFT NO.2 I ..---BUS GALLERY I I IHI CABLE SHAFT..J NO. I SECTION A-A SCALE A CABLE SHAFT lw I 14'-0"• [ INSPECTION HOIST 345 KV CABLES SECTION C-C SCALE B SECTION 0-0 SCALE C SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY PLATE F65EXHIBIT F DEVIL CANYON TRANSFORMER GALLERY PLAN AND SECTIONS o 4 8 FEET SCALE C ~e:::IIIIIIIIIIIIII~iiiiiiiiiiiiiiiill (1/4 INCH =I FEET> o 8 16 FEET SCALE B E2 ===a (1/8 INCH =I FEET) o 16 32 FEET SCALE A C I (1/16 INCH =I FEET) BUS GALLERY ISOLATED PHASE BUS MONORAIL AND 5 TON HOIST STAIRCASE OIL PIT (CRUSHED STONE) OIL SUMP COLLECTOR PIPE 43'-0" FIRE WALL ,r--~ (/-, I ) I I I I I I I I I I I I IIIt=-:t:.--:: o -~... SECTION A"A SCALE B ~ORIGINAL GROUND______SURFACE-------------~'---- SURGE CHAMBER ~ ~/TAILRACE TUNNEL "A,; f- """=,,1,=,, ~A -! 1-----'-----.., ~ORIGINAL GROUND SURFACE ,--...... -<.-.-, \/(AILRACEPORTAL ,,=~ 1 3iIIBI 1'';:3\1"'1,.l B .,.. NORMAL T.W.L. EL.855 DRAFT TUBE GATE GUIDE ------+1-1 SURGE CHAMBER-----H++_~ SURGE CHAMBER CRANE- DRAFT TUBE GATE ------/ 65+0060+00 STATIONING IN FEET FLOW- 5+000+00 700 900 1500 1100 800 1700 1000 1600 1800 1900 i!5 1300 i=:; W ..Jw 1200 I-::J 1400... 1!; PLATE F 66 SECTION C-C SCALE B EXHIBIT F 0 8 16 FEET SCALE Ci ,( 1/8 INCH =I FEET) 0 16 32 FEET SCALE BI ( 1/16 INCH =I FEET) 0 100 200 FEET SCALE Ai ( I INCH=100 FEET) •ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT DEVIL CANYON SURGE CHAMBER AND TAILRACE SECTIONS I 1 I =01 'I -LOi 1'-' '-SURGE CHAMBER ~ .. TAILRACE TUNNEL L ..CPROFILE SCALE A ROCK BOLTING AS REQUIRED SECTION A-A CONCRETE LINED TAILRACE TUNNEL SCALE C SECTION B-B SCALE B SECTION B-B SCALE B 0 "'",""-~)'''' \~~!ORIGINAL GROUND SURFACE '."ASSUMED ROCK SURFACE \4L '~c TAILRACE TUNNEL~.'''\1 " ~~I ~~ \j I ~I I I I I '\."'- IIr~il -,~I ~~l ~ ~~ 104 760 1000 640 660 920 800 I- I.lJ I.lJ 11. z ~ I-960;; I.lJ oJ I.lJ N3,223,OOO \ \ \. '. \..• \ \ \ A ~ \ -. \, \ \, \ os <Iio <D I.lJ PLAN SCALE A DEVIL CANYON TAILRACE PORTAL PLAN AND SECTIONS [iii]ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT PLATE F67 50 40 EXHIBIT F 0~~lIIIIiOjiiliiiiiiiiiiiiil80 FEETSCALE 8 ,_'(liNCH;40 FEET) o 100 FEET SCALE A i '(liNCH;50 FEET) "'~"""\~,~ORIGINAL GROUND SURFACE ASSUMED ROCK SURFACE \ 41 ~~''''\T -,'\~~EL.665 10~,,---"'-..~ I iTI--r-r--.~.~<, .,="'~''''I I I~---0 "0 ..~, i'ai ,,; '"<t ~ E L.769 1040 1000 I-... I.lJ...980 !: z 0 920i= <l>I.lJ oJ I.lJ 6eo 640 600 SECTION A-A SCALE B SWITCH YARDSWITCHYARD II..---,...·...L SPARE STATION SERVICE TRANSFORMER NO.3 zooo '1["" •I I I SWITCHYARD EXCITATION I TRANSFORMER -1 =-~=~==~I I L t) .j, cw--fI "BLACK START"I BUS----+--1-- ~ -----480V MAIN AUXILIARY SWITCHGEAR 7 SS ~STATION SERVICE TRANSFORMER NO.1 2000KVA,15000/480V 87 S PT.15KV /120-120V f-@@@@ ~TO GOVERNORc--CONTROL PT.15KV /120-120VL_METERING AND ~SYNCHRONIZING 167/192 MVA,0.9P.F. 15KV.30,60HZ 60/80°C,225 RPM SURGE PROTECTION p-i1t-1 11 f,"'~WIi.'fcIc91 t)t)IIHlf-o r-r--_-_-_-~--l!1--4.-16-<:;~Jy A AUXILIARY TRANSFORMER i)i)Ii f-- NO.I(SURFACEFACILITIES) 517.5MVA,15/4.16KV J..j,AUXILIARY TRANSFORMER /'::,1 r 51T NO.2(SURFACE FACI L1TIES) '=::::::~;~-=:+t-;~-~+~-=-~-~-,,)..J=H SS 5/7.5 MVA,Ir~~/_ ;:y t /'::,Ud ~_UCJ_---,, DIESEL GENERATOR I'500 KW,0.8 P.F. 480V,30,60HZ -=- AT SURFACE STATION SERVICE 87 TRANSFORMER NO.2 , DG 2000 KVA,15000/480V J ~~-.-,-;;;;-7 ~uu 0 y /'::, •~345KV r ou,FILLED I CABLE iA-l--...AVR ~ 1.1--1--...METERI NG SWITCHYARD SWITCHYARD r]1----........kJ.--""'"\..U0 EXCITATION TRANSFORMER 2500KVA D.C.FIELD ]FLASHING~.:----+~_~4~) 87G 87 GT SWITCHYARD GROUNDING ( TRANSFORMER] NOTE GENERATOR G2,G3,64,EQUIPPED EXACTLY AS GENERATOR 61 ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT DEVIL CANYON POWERHOUSE SINGLE LINE DIAGRAM EXHIBIT F PLATE F68 ---3 1 87 -sc;-1BI I T 345 KV BUS BI I ~I I ~METERING ~ ~~~-8 @ ,--p <1JcL '--J.,J.,'-- ,\H3~f--I"j-'.~.r;f-il \ 'I~ ~"~PBF - - ,\,\,\ '/'/-r-r-:- ~~---, Q I 345 KV BUS B2 I'i I T /~1 87 ~t-'1 / B2 ,~-"~-"~- "I-Uf'-o 87C 87GT "Hlr-o e-c-,-3 I "1_<11_-0 ~'If.-----lli--o <>- I I I +ALASKA POWER AUTHORITY oto o,TO POWERHOUSE 100o 200 FEET SCALE A ~I~~~:-''''';~I (lINCH'100 FEET) SWITCHYARD PLAN SCALE A I II II II I II II II E{II " II II II II II II II II II II I II I I flIIII II I II II II t=tIIIIII II II II II 345 KV II II I L4 rt=II II EjIIIIII \ II II II I II II II I I II II II II L3 II II II I rt=II II II E{ I II II II II II I 1\II Q I\L .C '--RELAY BUILDING ------------------- 800'-0"1--------1 ~-----------l I I I I I I I I I J TO GOLD CREEl< GOLD CREEK L4 GOLD CREEK L3 "I--m-~ POWERHOUSE UNIT I POWERHOUSE UN IT 2 POWERHOUSE UN I T 3 POWER HOUSE UN IT 4 SUSITNA HYDROELECTRIC PROJECT DEVIL CANYON SWITCHYARD SINGLE LINE DIAGRAM AND PLAN SINGLE LINE DIAGRAM EXHIBIT F PLATE F69 PLATE F70 ACCESS ROAD(PERMANENT) ACCESS ROAD (TEMPORARY) CONSTRUCTION ROAD PERMANENT SITE ROAD UTiLIDOR RAILROAD o 4 8 MILESiI (liNCH'4 MILES) SCALE SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY ~ "'-:-- -~ ....1i0C!OL.~ 4 -345 KV TRANSMISSION LINES TO GOLD CREEK DEVIL CANYON GENERAL LAYOUT SITE FACILITIES ---- EXHIBIT F o 1000 2000 FEET i i (I INCH • 1000 FEET) .1---------------1 l'(;~/ <,,<O«-?-y /J LOCATION MAP N 3.214.000 ~0 ~I ~0 0 0 0 8 00000000 ai 0 0 0 0 0 0 '"S:I N co <if e" iii CD CD 0 0'0 0 8~I '"CD:so '"so Ul Ul Ul Ul Ul Ul N 3,212,000 N 3,216,000 N 3,218.000 TO WATA~-- N 3,224,000 N 3220,000 N 3,222,000 N 3,228.000 N 3,226,000 PLATE F 71 ALASKA POWER AUTHORITY -----HAUL ROAD -----RUNOUT SUSITNA HYDROELECTRIC PROJECT EXHIBIT F DEVIL CANYON GENERAL LAYOUT CONSTRUCTION AND HAUL ROADS o 400 BOO FEET SCALE i !(I INCH =400 FEET) 1600 -~1700 __/==-~~}2-45 KV TRANSMISSION_l---,_~LINES TO GOLD CREEK .-J-~=,:::::::::7--LEGEND I I I V~ ~ NORMAL MAXIMUM RESERVOIR LEVEL ~---'---.i-\\'--__ CD STAFF AND FOREMAN HOUSINGoDORMITORIES G)MANAGER'S GUEST HOUSEoOWNER'S GUEST HOUSEoCONTRACTOR'S GUEST HOUSE CD CAMP MANAGER'S OFFICESoSECURITY CD FIRE AND OIL SPILLoHOSPITAL @ HELIPAD (MEDICAL EMERGENCY) @ COMMUNICATIONS CENTER @ KITCHEN AND DINING ~STAFF CLU8HOUSE @ RECREATION HALL @ 8ANK @ LAUNDRIES @ SOILS LA8 @ FOOD SERVICE WAREHOUSE @ WAREHOUSE @ MAINTENANCE GARAGEoPUMP HOUSE @ GENERATING STATION @ BUS STATION @ PARKING AND LAYDOWN AREAS @ 10' PERMAWALK ~16' PERMAWALK @ GYMNASIUM @ SWIMMING POOL @ HOCKEY RINK @ BASEBALL FIELD @ SOFTBALL FIELD @ FOOTBALL FIELD®FUEL STORAGE (50,000 GAL.) §STORE @ UTILIDOR @ WATER TREATMENT PLANT ®WATER RESERVOIR LEGEND ® ~l __________ -----~ I I~::=::::::L--I_@ +--E===::=::t91 @ 1600 1700 -_______________ -------------------- ------------I~0~[!J ------------)---------- -. _______'~1800 -_ ---------- --------rnJ@ ~ I 750 _______________ TO CONSTRUCTION VILLAGE 1800 T.32 N 3,220,000 T.31 N PLATE F 72 ALASKA POWER AUTHORITY EXHIBIT F DEVIL CANYON MAIN CONSTRUCTION CAMP SITE200a400FEET SCALE ~j~~~~iiiiiiiiiiiilj (I INCH •200 FEET) 1500 VILLAGE HOUSING -320 UNITS TEMPORARY HOUSING/UTILITIES FURNISHED BY OWNER. PARKING AREAS FAMILY HOUSING -2 B,R.-16 UNITS (24'.sd) FAMILY HOUSING -3 B_R-16 UNITS (24'.SO') FAMILY HOUSING -4 B.R-16 UNITS (2B'.sd) FAMILY HOUSING -3 B.R.-72 UNITS (/4'.60') FAMILY HOUSING-3 B.R.-200 UNITS (14'.60') @ SCHOOL-30'.3S'(12 UNITS) 107 GYM-100'.100' 108 SWIMMING POOL- 100' x 100' RECREATION CENTER 80'.100' STORE-100'.160' FIRE STATION-30'.40' GENERATING STATION -20'.30'(2 UNITS) UTILIDOR SEWER PUMPING STATION-50'.60' LEGEND 18=11 ~ ~-~--_._--~-- ~•...... ------------------ AND D~~TE~~~OYONNCAMPSITE _______________\75 0/ ~.>::"------~------- I {\-,At{ir - - f---1--.--- J 24' -----/800_ --,--10 ?!~.'113 f.:- ~@ ~ jcfl (" @ I 34'l I j I t-rrso I-~---~@--=:___..1 B=-®:i I 1-n;r ~.~. ,H\~----1----____L __i i--~----- r----t-------h----. ~1700_ 114 i --TOCO \7003,220,000 -----------==--~=------------ ------------~----~----1600 -------~ ------~ PLATE F 73 SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY DEVIL CANYON TEMPORARY VILLAGE EXHIBIT F 200 ISOO-_ o 400 FEET SCALE ~i~~~__iiii!(I INCH =200 FEET) --------------/----------------- 01 8.1 0'01~i PLATE F 74 GOLDEN VALLEY ELECTRIC ASSOC. r-, -:~~-j-~~---.. ~!:~-~~-11-,(-=+L...J 1 E []-J (- ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT RAILBELT 345 KV SINGLE LINE DIAGRAM EXHIBIT F DEVIL CANYON (FAIRBANKS) ESTER ,---------- I I I I, REMOVE IN FUTURE GOLD CREEK SHUNT REACTOR r-__~LF_I----t__+---l STAGING 1993 2002 185 MILES 6 X 170 MW UNITS 250 MVA 345/115-13.8 KV <nw -' ::; ...."''-------- I I I I I I I 79 MILES UNIVERSITY (ANCHORAGE) LU2 19 MILES KNIK ARM LK2 LUI ASSOCIATION LKI 75 MVA 345 -115 KV CHUGACH 44 MILES 1 250 MVA L,..u~u,...rill 345/230-13.8 KV I ,,-, rJ L _-, I I I I r1,r 1 ., LrJ LT~ :'---r-----l I I \t T PLATE F 75 o CONT. ~-r-~ROOM STOR. BLDG. 138 KV SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY 100 EXHiBiT F ,I MICROWAVE -~e~---I o:::-::Ir-,:>I -~::....--I I -'-11-'I l:;'::t:,~:! _-Ii,--.I '-11-',1.-~-------t j::.'=lf=-::l 11__J I___J , l..----------t,, ESTER SUBSTATION SINGLE LINE DIAGRAM AND PLAN [i]1-----------I o 200 FEET SCALE A"'i ~~~~iiiiii~'(I INCH'100 FEET) 15 KV 15 KV STATIC VAR COMPENSATOR 1400'-OU SERVICE ROAD I' , I, , I I ,, "345 KV SUBSTATION PLAN SCALE A 0_0 I til I I I I I I I 1 I ',,, ,, , I r -,,, I ' ( F 2 LF I TO GOLD CREEK 345/138-13.8 KV 150 MVA TRANSFORMER , I W""W 3 I 11:---}:-+-}:-~;--- - - - - - --., I 1 1, ~------+>----jH~HI' I I I I I I I I ( .I:--H:--O 0-1 I I 345/138-13.8KV ,n-htAAUJ 150 MVA TRANSFORMER If'I ,.J., I ~TJ ~----~-------~~ I STATIC VAR I COMPENSATION I I +GOLDEN VALLEY ELECTRIC ASSOCIATION GOLDEN VAL LEY ELECTRIC ASSOCIATION 1 .1 ...-1--+4----1>----j H3~HI' 1,1, L....----I---I-+-+--1H;~~" GOLD CREEK L F2 GOLDEN VALLEY ELECTRIC ASSOCIATION MET ERING -----1.-++--HI-l. 345KV BUS B2 345KV BUS B I 345/138-13.8KV 150 MVA TRANSFORMER 1,1, L..--------+:-1 r-T ~f---jl' GOLD CREEK LFI 8 B .'f--m--<> GOLDE N VALLEY ELECTRIC ASSOCIATION SINGLE LINE DIAGRAM '0, -ljl (I) TO DEVIL CANYON STORAGE BUILDING RELAY BUILDING MICROWAVE TOWER 4 100 SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY GOLD CREEK SWITCHYARD SINGLE LINE DIAGRAM AND PLAN a 200 FEET SCALE A "i"1IIIIIIIIIIIIIIIIIIIIII~iiiiiii~!(I INCH =100 FEET) 800'-OU ---- SWITCHYARD PLAN SCALE A ~_ _--.J --'- ~----.-------~SERVICE ROAD II I [II I :n=II II II ~r}--__I " II II r--Ill----I L I II I-~LJ---- , I II III,II III,n=II II I--<'~_ ==i'I I,II ~~::---II II'I t---<LJ- I II II II II r-- II II 'I~'I II IIIIII I I II II l- I II II 345 KV ::II II L- " II II II ::RJ LII II II IIIIIIIII'II II IIn=II II II t=n LIIIII II I II II II II I II I I I I I I I I-~r:~-r~f----H-------H-1 I1==1-.::::::::-1 II!:II J-- f-"-Lit---J(------- I LW3 LWI LF2 LW2 LFI TO ESTER TO WILLOW ESTER LFI L4 DEVIL CANYON (FUTURE) ESTER LF2 L3 DEVIL CANYON (FUTURE) WILLOW LWI J;J; 'if-l ~H H------' ..1..1 r-------t-"H~f_jl' L2 WATANA -3 I I -3t-1 J: -----l +-,---+------+-,----+---t-r-- - - - - - --l-'f -- I I I r' I _1. I ~r l I :~ I t ,'L1 fL!J L!J .-K 3 III ~,, Il~--1 :---4--1 :--1 :--t-- I J :Iit _1.,REMOVE IN I I FUTURE 'T' :H~ B7 B2 ..1 ..1 L---+--++-t-~LH' ..1 ..1.--+-+t----t--~J-,H' LI WATANA I ( r-~ I ~ I ~ I ~I - I _L , I"rIlI \ ----1-1.-----L---__ (FUTURE) WILLOW WILLOW LW3 LW2 •I I I I I 'Ii--m--0 0---i ·IHIf-<> ~'---J.'I~ I ....1\ I I I I I I I ---,------ I I 345 KV BUS I I ----tr------ I I I I I (I I,1, I I '~J I I ~METERING-t--:::::----ti+:b I I f\ I I J , , I L{W W I ,3 'T L __--+-~f--~t--4--!{--HI I I I I I I I I I I I I I SINGLE LINE DIAGRAM EXHIBIT F PLATE F 76 SERVICE CENTER 'I I ?1I':'::: -='jL --1...-.-J '0 I 'b 2 138 KV ----LW3 ----- L.----RELAY BUILDING _ f j75 MVA3PHASE TRANSFORMER ( SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY 100 [i]~I------------I o 200 FEET SCALE A~i~~..IJi:"iiiiiiiii~1 (liNCH =100 FEET) SUBSTATION PLAN SCALE A ENERGY MANAGEMENT CENTER 1 SERVICE ROAD CONTROL BLOG.- LWI GOLD CREEK -~" lIHH--O 0---- I '/- 1 1 'H I~I__+---------, LW2 GOLD CREEK I 1 1"HI~I__+_-----__, -u LW3 GOLD CREEK i I I \ t---~-11' ,,~~Ir~~-t I I I I I ~ I I 1'-- ~w 3'1"H:-.,HI/------' .I.I I I r ,I t ~I I 1 1 L-+4+-----+-.--..,H~Hh KNIK ARM LK 2 .IHlt---oi NO.I TRANSFORMERT"'''',%""" MATANUSKA ELECTRIC ASSOCIATION I' ",1 ",1 87 BI t-- ,,J~-Lf--+--------, TC kIDl-++--f I f-= METERING ®'-- I' 1/ t.~ 87 ~ @ @ @ u..W NO.2 TRANSFORMER rr,'n 75 MVA.34/l/138 KV'------I, I 345 KV BUS BI -.,-T ---------- - - -..- - -+-t--------+------+-....---....---------f-.,..------!-------t-.,. I '/ I ( I f.l..l I 'f I ~ I ~U 1 I\w w L--------+--a--:: I -:f.- -i1 , I~~ 1 l_I J 1 1WJ.; \3T r---- - --+-·:(--:(-~-:t--·:llIr j I I t I I ~ I I ~ I I ,1" I I tTl I I I I I \ I ---4-J.----------I--..-----+-..-.---.....----__j......._----l------I-~---__Ii-----__j.......-- I 1__3~5....!<':.~~B2 ___-+-------+--------<~-_+_----f_-----~------+_------' ~ llt-ilt--o o--l I Iutu NO.3 TRANSFORMER (YTn 75 MVA,34/l1138KV I I t MATANUSKA ELECTRIC ASSOCIATION KNIK ARM LK 3 t I I I I 1I1--m--o-~ I ":---,-~, MATANUSKA ELECTRIC ASSOCIATION WILLOW SUBSTATION SINGLE LINE DIAGRAM AND PLAN EXHIBIT F PLATE F77 SINGLE LINE DIAGRAM 1110'-0" SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY 100 MICROWAVE TOWER o 200 FEET SCALE A'~I1IIIIIIIlI1IIIIIIIlI~_~(lINCH:100 FEET) SUBSTATION PLAN SCALE A SERVICE ROAD 75 MVA I (I 3 PHASE -w-'C~TRANSFORMER II II II If-3E:-:::: rt ---II 115 KV I ~II II 345 KV :: I LU2 0IIII II II ~ ) ro ""'''~"I !!!!i:~~:.,'II 'STOR. II II II ~mEJIJlJI U t8J I-- SHUNTIREACTOR I LK 31 TO WILLOW LK 21 I I I J..,W 3,...,.., -:t--:t-+-~l;--:ll ----3 i----3~I KNIK ARM TRANSFORMER 75 MVA,345-115 KV 1 1 r-i-+-t-__--1~\-IH3~HI' I I I I I I I I I ~- WILLOW LK3 METERING ---!--4 1 1 L..-_-+-_++~~H3~H" 1 1 ,.------~~....,H~HI, WILLOW LK2 .'~ 'Hlf-o METERING-f----+H--_+, 345 KV BUS BI 1 1 r------......----1H~HII ..L ..L 1---+----1H3~(__j11 .~ "Hlr-> WILLOW LKI ,~~...• __"~c-f__ _"~j II--~0--(-t------------f-______1 1__ "Hlf-o o-T e 'HIH'o-t "f---/'-\~IN r---8--I-1 "I--.:»:-~ I I I " 'If-'-f-~"""VJ..;J.;...v__'±'...,.,.-I-i-----+ - REACTOR '-''I @@@ I SUBMARINE CABLE~- UNDER KNI K ARM ~ 51R 'iHlf-o 51N "~ LUI UNIVERSITY LU2 UNIVERSITY KNIK ARM SUBSTATiON SINGLE LINE DIAGRAM AND PLAN M ATANUSKA ELECTRIC ASSOCIATION EXHIBIT F PLATE F 7B SINGLE LINE DIAGRAM I I 1 =::jl= CO}! '0 LU2 f- , 0 u 0 :!: I IC VAR ENSATOR 250 MVA I 0-SINGLE PHASE TRANSFORMERS 'I :I I, I ,I I iii SUBSTATION PLAN SCALE A CONTROL ROOM SERVICE ROAD SERVICE AND STORAGE BUILDING 'I 'i'v'LMICROWAVEc\C',l-TOWER ---------..., I ,,,, 1:------- - , I 1.1..1 lJ...1 III 3 \ 'H:-"-~H:- ~1 l ..----t,\-I~.L Hi I - "rS ",[ / KNI K ARM LU2 - >-11 .---+--+--+--t-----iHtI.--,H /- t-1---t1@-- 1 1 HtLHif----+-I--+------l METER@--'NG""", 21B 50 -I® I I METERING I I 1 1 ,...------.t-lH°rL Hi' - '-1,.r. '---tL--i H °t-I-,(------1 !1 / "1---.- 345KV BUS BI r KNIK ARM LUI 345KV BUS B 2 r 1 L J I 11,- 'H~~r-""_\_---, / ,, ..L ..L \3 'T'r---------~H:-4-~:--a' 100 SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY a 200 FEET SCALE A ~I~~~~iiiiii~1 (I INCH'100 FEET) ANCHORAGE MUN I CI PAL L IGHTa POWER ANCHORAGE MUNICI PAL LIGHT a POWER "Hlr-o - I ( ,'H,:-~~-+ I 250MVA "'".--'"250MVA I TRANSFORMER 9~J..)"TRANSFORMER llAAUpr+ 345/IIS-13,BKV o4S/IiS-lo.8KV T I ,L,I I ,I '--+-__--...j J': ~STATIC VAR IfCOMPENSATIONI t 87 TC 250 MVA TRANSFORMER"':1'345/230-13.8KV~[ 82 / 250 MVA "t-V..j..U..AjJJr:TRANS FORMERY345/230-1 3.B KV CHUGACH ELECTRIC ASSOCIATION TIC VAR PENSATION 250 MVA TRANSFORMER 345/230-13.8KY CHUGACH ELECTRIC ASSOCIATION UNIVERSITY SUBSTATION SINGLE LINE DIAGRAM AND PLAN ...L T l~TATIC VAR I f COMPENSATION EXHIBIT F PLATE F 79 CHUGACH ELECTRIC ASSOCIATION CHUGACH ELECTRIC ASSOCIATION SINGLE LINE DIAGRAM NOTES: I.BASED ON PROPOSED STRUCTURES FOR INTERTIE PROJECT. 2.AVERAGE CONDUCTOR SAG -37 FEET. 3.AVERAGE TOWER SPACING -1400 FEET. - - "'co \ 1\;;-;\ >-\~ -",\ I'-\ \- \ ,,,"I.I(~\'0\. RUCTURE 0 20 40 FEET SCALE j i ( I INCH'20 FEET) LiJ!ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT POLE TYPICAL TRANSM ISSION LINE STRUCTURES EXHIBIT F I PLATE F80 14' 345 kV SINGLE CIRCUIT TANGENT 345 kV MEDIUM ANGLE (8 ° -30°)ST ! 28' 22.5'L 22.5' " "'ex> '">-.... 9' -.,,1 ~ ---17'-.,. co \ \ /\\/~I n:///>(>- !::. /\0 N/ex>'" /35'\ // //// ",?i'111·\<-11'?0:" 345 kV HEAVY ANGLE (8"_50°)DEAD END STRUCTURE 345 kV TANGENT OR LIGHT ANGLE STRUCTURE r PLATE F81 15 LEGEND t..",~g6ZR~cio~RANSMISSION SCALE ~O==~iomo__;ii30 MILES (1":15 MILES) SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY EXHIBIT F 345 KV TRANSMISSION CORRIDOR 345 KV SYSTEM SINGLE LINE DIAGRAM AND TRANSMISSION CORRIDOR GOLOEN VALLEYELECTRIC ASSOC. r-"'"r---_ _..J L,...... j---------- I 1 I I I NUMBER WIDTH OF DiSTANCE BETWEEN DiSTANCE FROM LINE OF LINES R.O.w.(FT.)LINES\FT.)TO EDGE OF RO.W.(FT.I 190 95 300 105 ±95 400 105 ±95 510 I05±95 STAGING -1993 ---2002 187 MILES LF2 'l LFI SHUNT REACTOR ESTER LWI (FAIR8ANKS 1--.,...- I I,', 'TJ REMOVE INFUTURE GOLD CREEK LW2 250 MVA 345/115-13.8 KV "'~ i "ro '-----------. 76 MILES .1:-,••,.,1;::,':.,-Y- II 1 I,1, LrJ 1 I I I j , I -I~~- --+-,----r--f--~__+ 1 I I I I .i, I ,II-T" , I, , I I L_.. I I I -, ;-!~;L)l lT J L T-,1 1 I :I 1--...- -+_I-_-\_...-........-+:-- - ...--r IL3 IL4 :L------------------------~~~l I IL,I I I I Ii~i--~---I I I 2002 INSTALLATION -j-~---_j_._-----.---I i J !.L "L,III I I I I IIC(I ']"TL_.,L--;+-_ DEVIL _1,,.e,,1,I I ---1 1 ~~l I I I CANYON ,_~~~~J':I I ;.L ~I ~l.~I r .j.,I I :'I':'::".I I _~-J_---~-l----~-L~--I I I IV I 1.__ 16 X 170 MW UNITS ~.±-x150 MW UNITI-_ v UNIVERSITY (ANCHORAGEI ---------, I I I I I I ANCHORAGE MUNICIPAL LIGHT a POWER o 345 KV TRANSMISSION SYSTEM SINGLE LINE DIAGRAM WILLOW LU2 18 MILES KNIK ARM LUI 75 MVA 345-115 KV LK2 LKI r-----l '.I<---<-i : ,I : I ~----- -~SUBMARI~CABLE--- '\UNDER KNIK ARM <~-,-.-,-"-[}\ CHUGACH ELECTRIC ASSOCIATION 40 MILES NOTE' I.ESTIMATEO GROUND RESISTIVITY FOR DESIGN IS 50 OHMS.