Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
City of Wales Heat Recovery Technical Specifications - Jun 2020 - REF Grant 7091234
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±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±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¶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±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¶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¶VRZQSODQWIURPUHVLQRIWKHVDPHVSHFLILFDWLRQIURPWKHVDPH UDZPDWHULDO$OOILWWLQJVVKDOOEHFHUWLILHGE\16),QWHUQDWLRQDODVFRPSO\LQJZLWK16) DQG$670) %)LWWLQJVVKDOOEH1LURQ&OLPD335&7RUDSSURYHGHTXDO &LW\RI:DOHV +HDW5HFRYHU\'HVLJQ ,VVXHGIRU&RQVWUXFWLRQ ± ,QVXODWHG3LSHDQG)LWWLQJV 12167$1'$5'$1*/(),77,1*6 $)RUILWWLQJVWKDWUHTXLUHDQJOHVIRUZKLFKVWDQGDUGILWWLQJVDUHQRWRIIHUHGPLWHUHGVHJPHQWHG HOERZVILWWLQJVVKDOOEHSURYLGHGLQDFFRUGDQFHZLWK1XSL1LURQUHFRPPHQGDWLRQV %%XWWIXVLRQMRLQWVVKDOOEHXVHGDWHDFKPLWHUHGMRLQWLQWKHVHJPHQWHGHOERZVLQDFFRUGDQFH ZLWK1XSL1LURQUHFRPPHQGDWLRQV :$55$17< $0DQXIDFWXUHUVKDOOZDUUDQWSLSHDQGILWWLQJVIRU\HDUVWREHIUHHRIGHIHFWVLQPDWHULDOVRU PDQXIDFWXULQJ %:DUUDQW\VKDOOFRYHUODERUDQGPDWHULDOFRVWVRIUHSDLULQJDQGRUUHSODFLQJGHIHFWLYHPDWHULDOV DQGUHSDLULQJDQ\LQFLGHQWDOGDPDJHFDXVHGE\IDLOXUHRIWKHSLSLQJV\VWHPGXHWRGHIHFWVLQ PDWHULDOVRUPDQXIDFWXULQJ &:DUUDQW\VKDOOEHLQHIIHFWRQO\XSRQVXEPLVVLRQE\WKHFRQWUDFWRUWRWKHPDQXIDFWXUHUYDOLG SUHVVXUHOHDNWHVWGRFXPHQWDWLRQLQGLFDWLQJWKDWWKHV\VWHPZDVWHVWHGDQGSDVVHGWKH PDQXIDFWXUHU¶VSUHVVXUHOHDNWHVW )86,21 $$OOIXVLRQRI335&7SLSHVKDOOEHVRFNHWIXVLRQH[FHSWDVQRWHGLQVHFWLRQ,IVRFNHW IXVLRQLVQRWIHDVLEOHGXHWRVSDFHFRQVWUDLQWVDWVSHFLILFMRLQWV&RQWUDFWRUVKDOOUHTXHVW DXWKRUL]DWLRQIURPWKH(QJLQHHUWRDOORZIRUHOHFWURIXVLRQFRXSOLQJVWREHXVHG %$OOIXVLRQZHOGMRLQWVVKDOOEHPDGHLQDFFRUGDQFHZLWKWKHSLSHDQGILWWLQJPDQXIDFWXUHU¶V VSHFLILFDWLRQVDQGSURGXFWVWDQGDUGV &)XVLRQZHOGWRROLQJDQGZHOGLQJPDFKLQHVVKDOOEHDVVSHFLILHGE\WKHSLSHDQGILWWLQJV PDQXIDFWXUHU '3ULRUWRMRLQLQJWKHSLSHDQGILWWLQJVVKDOOEHSUHSDUHGLQDFFRUGDQFHZLWK$670)DQG WKHPDQXIDFWXUHU¶VVSHFLILFDWLRQV (-RLQWSUHSDUDWLRQVHWWLQJDQGDOLJQPHQWIXVLRQSURFHVVFRROLQJWLPHVDQGZRUNLQJSUHVVXUH VKDOOEHLQDFFRUGDQFHZLWKWKHSLSHDQGILWWLQJPDQXIDFWXUHU¶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±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¶V FLUFXPIHUHQFHDWDJLYHQFURVVVHFWLRQ &7KHQRPLQDOGLDPHWHUVKDOOEHWKHLQVLGHGLDPHWHUDVPHDVXUHGEHWZHHQWKHLQQHUPRVWSRUWLRQ RIWKHFRUUXJDWLRQVZLWKDGLPHQVLRQDOWROHUDQFHRI´ '$OOMRLQWVLQWKHDOXPLQXPRXWHUMDFNHWIDEULFDWHGDURXQGILWWLQJVVKDOOEHZHOGHGZLWKD FRQWLQXRXVEHDGUHVXOWLQJLQDILQLVKHGMDFNHWWKDWLVZDWHUWLJKWSHUWKHUHTXLUHPHQWVRIVHFWLRQ $ &LW\RI:DOHV +HDW5HFRYHU\'HVLJQ ,VVXHGIRU&RQVWUXFWLRQ ± ,QVXODWHG3LSHDQG)LWWLQJV (7KH&RQWUDFWRUVKDOOSURYLGHFRPSDQ\QDPHDQGSURGXFWLRQGDWHPRQWKDQG\HDURQWKH RXWHUMDFNHWRIHDFKSLSHDQGILWWLQJ,QIRUPDWLRQVKDOOEHHQJUDYHGRQDOXPLQXPMDFNHWVZLWK LQFKWRóLQFKKLJKOHWWHULQJZLWKLQ´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±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´[´[´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±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±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¶V VSHFLILFDWLRQVDQGSURGXFWVWDQGDUGV &)XVLRQZHOGWRROLQJDQGZHOGLQJPDFKLQHVVKDOOEHDVVSHFLILHGE\WKHSLSHDQGILWWLQJV PDQXIDFWXUHU '3ULRUWRMRLQLQJWKHSLSHDQGILWWLQJVVKDOOEHSUHSDUHGLQDFFRUGDQFHZLWK$670)DQG WKHPDQXIDFWXUHU¶VVSHFLILFDWLRQV (-RLQWSUHSDUDWLRQVHWWLQJDQGDOLJQPHQWIXVLRQSURFHVVFRROLQJWLPHVDQGZRUNLQJSUHVVXUH VKDOOEHLQDFFRUGDQFHZLWKWKHSLSHDQGILWWLQJPDQXIDFWXUHU¶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±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