Data Set Properties
Data Set:Report Created:6/7/2013 14:55
Variables Values
Latitude N 62° 6' 0.000"
Longitude W 163° 35' 0.000"
Elevation 44 m
Start date 1/16/2013 13:00
End date 5/25/2013 12:00
Duration 4.2 months
Length of time step 10 minutes
Calm threshold 0 m/s
Mean temperature -11.0 °C
Mean pressure 100.8 kPa
Mean air density 1.340 kg/m³
Power density at 50m 297 W/m²
Wind power class 2 (Marginal)
Power law exponent 0.0936
Surface roughness 0.00481 m
Roughness class 0.63
Roughness description Snow surface
Page 2 of 6Windographer 1.50 Data Set Summary Report
Wind Speed and Direction
Page 3 of 6Windographer 1.50 Data Set Summary Report
Wind Shear
Page 4 of 6Windographer 1.50 Data Set Summary Report
Turbulence Intensity
Page 5 of 6Windographer 1.50 Data Set Summary Report
Data Column Properties
Label Units Height Possible
Records
Valid
Records
Recovery
Rate (%)
Mean Min Max Std. Dev
Speed 50 m A m/s 50 m 18,570 18,570 100 4.72 0.40 22.80 4.75
Speed 50 m A SD m/s 18,570 18,570 100 0.328 0.000 5.100 0.340
Speed 50 m A Max m/s 18,570 18,570 100 5.55 0.40 25.80 5.39
Speed 50 m A Min m/s 18,570 18,570 100 3.86 0.40 20.50 4.06
Speed 50 m B m/s 50 m 18,570 18,570 100 5.32 0.40 22.70 4.61
Speed 50 m B SD m/s 18,570 18,570 100 0.389 0.000 5.800 0.341
Speed 50 m B Max m/s 18,570 18,570 100 6.35 0.40 26.10 5.12
Speed 50 m B Min m/s 18,570 18,570 100 4.35 0.40 20.50 4.02
Speed 40 m m/s 40 m 18,570 18,570 100 5.00 0.30 22.10 4.56
Speed 40 m SD m/s 18,570 18,570 100 0.384 0.000 5.600 0.357
Speed 40 m Max m/s 18,570 18,570 100 5.98 0.30 25.80 5.20
Speed 40 m Min m/s 18,570 18,570 100 4.02 0.30 19.40 3.90
Direction 46 m °46 m 18,570 18,570 100 224.5 0.0 359.0 96.9
Direction 46 m SD °18,570 18,570 100 4.8 0.0 122.0 8.0
Direction 46 m Max °18,570 18,570 100 0 0 0 0
Direction 46 m Min °18,570 18,570 100 0 0 0 0
Direction 40 m °40 m 18,570 18,570 100 224.9 0.0 359.0 97.1
Direction 40 m SD °18,570 18,570 100 4.7 0.0 127.0 8.0
Direction 40 m Max °18,570 18,570 100 0 0 0 0
Direction 40 m Min °18,570 18,570 100 0 0 0 0
Temperature °C 18,570 18,570 100 -11.03 -29.20 7.20 7.54
Temperature SD °C 18,570 18,570 100 0.090 0.000 1.700 0.093
Temperature Max °C 18,570 18,570 100 -10.82 -28.90 8.20 7.56
Temperature Min °C 18,570 18,570 100 -11.17 -29.20 6.90 7.52
RH-5 Humidity %RH %RH 18,570 18,570 100 55.59 0.00 99.20 27.70
RH-5 Humidity %RH SD %RH 18,570 18,570 100 0.64 0.00 25.10 1.65
RH-5 Humidity %RH Max %RH 18,570 18,570 100 56.80 0.00 99.50 27.18
RH-5 Humidity %RH Min %RH 18,570 18,570 100 54.21 0.00 98.70 28.33
voltmeter volts 18,570 18,570 100 11.09 0.90 15.20 4.66
voltmeter SD volts 18,570 18,570 100 0.043 0.000 4.500 0.174
voltmeter Max volts 18,570 18,570 100 11.20 1.00 15.50 4.60
voltmeter Min volts 18,570 18,570 100 10.97 0.90 15.10 4.74
Speed 41 m m/s 41 m 18,570 18,570 100 3.71 0.30 21.10 4.10
Speed 41 m SD m/s 18,570 18,570 100 0.339 0.000 6.100 0.434
Speed 41 m Max m/s 18,570 18,570 100 4.59 0.30 24.60 4.84
Speed 41 m Min m/s 18,570 18,570 100 2.88 0.30 18.10 3.34
Speed 31 m m/s 31 m 18,570 18,570 100 4.66 0.30 21.40 4.62
Page 6 of 6Windographer 1.50 Data Set Summary Report
Label Units Height Possible
Records
Valid
Records
Recovery
Rate (%)
Mean Min Max Std. Dev
Speed 31 m SD m/s 18,570 18,570 100 0.367 0.000 5.600 0.341
Speed 31 m Max m/s 18,570 18,570 100 5.61 0.30 24.20 5.26
Speed 31 m Min m/s 18,570 18,570 100 3.72 0.30 18.90 3.92
Speed 32 m m/s 32 m 18,570 18,570 100 4.47 0.30 21.00 4.49
Speed 32 m SD m/s 18,570 18,570 100 0.371 0.000 4.500 0.370
Speed 32 m Max m/s 18,570 18,570 100 5.42 0.30 24.30 5.22
Speed 32 m Min m/s 18,570 18,570 100 3.51 0.30 17.80 3.72