Loading...
HomeMy WebLinkAboutScammon Bay Wind Feasibility Data Analysis - Mar 2013 - REF Grant 7040022Page 1 of 6Summary Report: Scammon Bay 0044.windog Data Set Properties Report Created:3/14/2013 11:38 using Windographer 2.4.11 Filter Settings:<Unflagged data> Variable Value Latitude N 62° 6' 0.000" Longitude W 163° 35' 0.000" Elevation 44 m Start date 9/25/2012 09:00 End date 3/11/2013 00:00 Duration 5.5 months Length of time step 10 minutes Calm threshold 0 m/s Mean temperature -9.93 °C Mean pressure 100.8 kPa Mean air density 1.335 kg/m³ Power density at 50m 998 W/m² Wind power class 7 (Superb) Power law exponent 0.147 Surface roughness 0.044 m Roughness class 1.32 Roughness description Crops Page 2 of 6Summary Report: Scammon Bay 0044.windog Wind Speed and Direction Page 3 of 6Summary Report: Scammon Bay 0044.windog Wind Shear Page 4 of 6Summary Report: Scammon Bay 0044.windog Turbulence Intensity Page 5 of 6Summary Report: Scammon Bay 0044.windog Data Column Properties Number Label Units Height Possible Records Valid Records Recovery Rate (%) Mean Min Max Std. Dev 1 Speed 50 m A m/s 50 m 23,994 9,446 39.37 9.72 0.40 26.80 4.95 2 Speed 50 m A SD m/s 50 m 23,994 9,446 39.37 0.759 0.000 5.100 0.405 3 Speed 50 m A Max m/s 50 m 23,994 9,446 39.37 11.68 0.40 32.30 5.63 4 Speed 50 m A Min m/s 50 m 23,994 9,446 39.37 7.71 0.40 21.60 4.27 5 Speed 50 m B m/s 50 m 23,994 10,855 45.24 9.33 0.40 26.90 5.04 6 Speed 50 m B SD m/s 50 m 23,994 10,855 45.24 0.736 0.000 6.600 0.399 7 Speed 50 m B Max m/s 50 m 23,994 10,855 45.24 11.25 0.40 32.60 5.68 8 Speed 50 m B Min m/s 50 m 23,994 10,855 45.24 7.43 0.40 22.40 4.40 9 Speed 40 m m/s 40 m 23,994 9,621 40.10 9.35 0.30 26.10 4.69 10 Speed 40 m SD m/s 40 m 23,994 9,621 40.10 0.783 0.000 5.600 0.425 11 Speed 40 m Max m/s 40 m 23,994 9,621 40.10 11.41 0.30 32.30 5.41 12 Speed 40 m Min m/s 40 m 23,994 9,621 40.10 7.31 0.30 20.10 4.05 13 Direction 46 m °46 m 23,994 10,289 42.88 291.2 0.0 359.0 97.4 14 Direction 46 m SD °46 m 23,994 10,289 42.88 8.8 0.0 107.0 10.0 15 Direction 46 m Max °46 m 23,994 10,289 42.88 0 0 0 0 16 Direction 46 m Min °46 m 23,994 10,289 42.88 0 0 0 0 17 Direction 40 m °40 m 23,994 10,289 42.88 285.9 0.0 359.0 95.2 18 Direction 40 m SD °40 m 23,994 10,289 42.88 9.1 0.0 122.0 10.1 19 Direction 40 m Max °40 m 23,994 10,289 42.88 0 0 0 0 20 Direction 40 m Min °40 m 23,994 10,289 42.88 0 0 0 0 21 Temperature °C 23,994 23,994 100.00 -9.93 -29.20 8.00 8.05 22 Temperature SD °C 23,994 23,994 100.00 0.088 0.000 3.200 0.092 23 Temperature Max °C 23,994 23,994 100.00 -9.72 -28.90 8.20 8.04 24 Temperature Min °C 23,994 23,994 100.00 -10.06 -29.20 7.90 8.06 25 RH-5 Humidity %RH %RH 23,994 23,994 100.00 59.1 0.0 100.2 29.0 26 RH-5 Humidity %RH SD %RH 23,994 23,994 100.00 0.80 0.00 31.20 1.87 27 RH-5 Humidity %RH Max %RH 23,994 23,994 100.00 60.6 0.0 100.4 28.3 28 RH-5 Humidity %RH Min %RH 23,994 23,994 100.00 57.2 0.0 100.4 29.8 29 voltmeter volts 23,994 23,994 100.00 9.81 0.90 15.30 4.38 30 voltmeter SD volts 23,994 23,994 100.00 0.060 0.000 4.500 0.185 31 voltmeter Max volts 23,994 23,994 100.00 9.95 1.00 15.60 4.32 32 voltmeter Min volts 23,994 23,994 100.00 9.63 0.90 15.30 4.48 33 Speed 41 m m/s 41 m 23,994 9,774 40.74 8.71 0.30 24.90 4.55 34 Speed 41 m SD m/s 41 m 23,994 9,774 40.74 0.803 0.000 4.900 0.444 35 Speed 41 m Max m/s 41 m 23,994 9,774 40.74 10.78 0.30 31.00 5.31 36 Speed 41 m Min m/s 41 m 23,994 9,774 40.74 6.61 0.30 17.80 3.80 37 Speed 31 m m/s 31 m 23,994 10,663 44.44 8.88 0.30 25.00 4.80 38 Speed 31 m SD m/s 31 m 23,994 10,663 44.44 0.758 0.000 6.600 0.423 39 Speed 31 m Max m/s 31 m 23,994 10,663 44.44 10.85 0.30 31.00 5.56 40 Speed 31 m Min m/s 31 m 23,994 10,663 44.44 6.91 0.30 20.40 4.07 41 Speed 32 m m/s 32 m 23,994 10,558 44.00 8.56 0.30 23.70 4.46 42 Speed 32 m SD m/s 32 m 23,994 10,558 44.00 0.811 0.000 6.900 0.436 43 Speed 32 m Max m/s 32 m 23,994 10,558 44.00 10.68 0.30 30.00 5.27 44 Speed 32 m Min m/s 32 m 23,994 10,558 44.00 6.49 0.30 17.80 3.72 45 Air Density kg/m³23,994 23,994 100.00 1.335 1.249 1.439 0.041 46 Speed 50 m A TI 23,994 9,446 39.37 0.100 0.000 1.625 0.096 47 Speed 50 m B TI 23,994 10,855 45.24 0.108 0.000 2.000 0.119 48 Speed 41 m TI 23,994 9,774 40.74 0.118 0.000 1.167 0.107 49 Speed 40 m TI 23,994 9,621 40.10 0.108 0.000 1.600 0.102 50 Speed 32 m TI 23,994 10,558 44.00 0.120 0.000 1.000 0.105 51 Speed 31 m TI 23,994 10,663 44.44 0.108 0.000 1.700 0.103 52 Speed 50 m A WPD W/m²23,994 9,446 39.37 1,084 0 12,160 1,400 53 Speed 50 m B WPD W/m²23,994 10,855 45.24 1,019 0 12,297 1,382 Page 6 of 6Summary Report: Scammon Bay 0044.windog Number Label Units Height Possible Records Valid Records Recovery Rate (%) Mean Min Max Std. Dev 54 Speed 41 m WPD W/m²23,994 9,774 40.74 802 0 9,753 1,067 55 Speed 40 m WPD W/m²23,994 9,621 40.10 950 0 11,232 1,192 56 Speed 32 m WPD W/m²23,994 10,558 44.00 757 0 8,410 991 57 Speed 31 m WPD W/m²23,994 10,663 44.44 883 0 9,871 1,200