Loading...
HomeMy WebLinkAboutShishmaref Heat Recovery - 95% Design Project Manual - Apr 2020 - REF Grant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±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ƒ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±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¶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±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¶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¶VRZQSODQWIURPUHVLQRIWKHVDPHVSHFLILFDWLRQIURPWKHVDPH UDZPDWHULDO$OOILWWLQJVVKDOOEHFHUWLILHGE\16),QWHUQDWLRQDODVFRPSO\LQJZLWK16) DQG$670) %)LWWLQJVVKDOOEH1LURQ&OLPD335&7RUDSSURYHGHTXDO  &LW\RI6KLVKPDUHI  +HDW5HFRYHU\3URMHFW  '(6,*1  ±   ,QVXODWHG3LSHDQG)LWWLQJV :$55$17< $0DQXIDFWXUHUVKDOOZDUUDQWSLSHDQGILWWLQJVIRU\HDUVWREHIUHHRIGHIHFWVLQPDWHULDOVRU PDQXIDFWXULQJ %:DUUDQW\VKDOOFRYHUODERUDQGPDWHULDOFRVWVRIUHSDLULQJDQGRUUHSODFLQJGHIHFWLYHPDWHULDOV DQGUHSDLULQJDQ\LQFLGHQWDOGDPDJHFDXVHGE\IDLOXUHRIWKHSLSLQJV\VWHPGXHWRGHIHFWVLQ PDWHULDOVRUPDQXIDFWXULQJ &:DUUDQW\VKDOOEHLQHIIHFWRQO\XSRQVXEPLVVLRQE\WKHFRQWUDFWRUWRWKHPDQXIDFWXUHUYDOLG SUHVVXUHOHDNWHVWGRFXPHQWDWLRQLQGLFDWLQJWKDWWKHV\VWHPZDVWHVWHGDQGSDVVHGWKH PDQXIDFWXUHU¶VSUHVVXUHOHDNWHVW )86,21 $$OOIXVLRQRI335&7SLSHVKDOOEHVRFNHWIXVLRQ,IVRFNHWIXVLRQLVQRWIHDVLEOHGXHWRVSDFH FRQVWUDLQWVDWVSHFLILFMRLQWV&RQWUDFWRUVKDOOUHTXHVWDXWKRUL]DWLRQIURPWKH(QJLQHHUWRDOORZ IRUHOHFWURIXVLRQFRXSOLQJVWREHXVHG%XWWIXVLRQLVDOORZHGIRUQRQVWDQGDUGDQJOHILWWLQJV DVUHTXLUHGDQGVKRZQRQWKHGUDZLQJV7KHLQWHUQDOZHOGEHDGVKDOOEHUHPRYHGIRUEXWW IXVLRQMRLQWV %$OOIXVLRQZHOGMRLQWVVKDOOEHPDGHLQDFFRUGDQFHZLWKWKHSLSHDQGILWWLQJPDQXIDFWXUHU¶V VSHFLILFDWLRQVDQGSURGXFWVWDQGDUGV &)XVLRQZHOGWRROLQJDQGZHOGLQJPDFKLQHVVKDOOEHDVVSHFLILHGE\WKHSLSHDQGILWWLQJV PDQXIDFWXUHU '3ULRUWRMRLQLQJWKHSLSHDQGILWWLQJVVKDOOEHSUHSDUHGLQDFFRUGDQFHZLWK$670)DQG WKHPDQXIDFWXUHU¶VVSHFLILFDWLRQV (-RLQWSUHSDUDWLRQVHWWLQJDQGDOLJQPHQWIXVLRQSURFHVVFRROLQJWLPHVDQGZRUNLQJSUHVVXUH VKDOOEHLQDFFRUGDQFHZLWKWKHSLSHDQGILWWLQJPDQXIDFWXUHU¶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ƒ) $670'  &RUH'HQVLW\5DQJH   WROEVIW $670'  0LQLPXP&RPSUHVVLYH6WUHQJWK SVL  SDUDOOHODQGSHUSHQGLFXODUWRSLSHD[LV  $670'  0D[LPXP:DWHU$EVRUSWLRQ  OEIW &LW\RI6KLVKPDUHI  +HDW5HFRYHU\3URMHFW  '(6,*1  ±   ,QVXODWHG3LSHDQG)LWWLQJV $670'  'LPHQVLRQDO6WDELOLW\   DWƒ)  0D[LPXP/LQHDU&KDQJH DWƒ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¶V FLUFXPIHUHQFHDWDJLYHQFURVVVHFWLRQ &7KHQRPLQDOGLDPHWHUVKDOOEHWKHLQVLGHGLDPHWHUDVPHDVXUHGEHWZHHQWKHLQQHUPRVWSRUWLRQ RIWKHFRUUXJDWLRQVZLWKDGLPHQVLRQDOWROHUDQFHRI´ '$OOMRLQWVLQWKHDOXPLQXPRXWHUMDFNHWIDEULFDWHGDURXQGILWWLQJVVKDOOEHZHOGHGZLWKD FRQWLQXRXVEHDGUHVXOWLQJLQDILQLVKHGMDFNHWWKDWLVZDWHUWLJKWSHUWKHUHTXLUHPHQWVRIVHFWLRQ $ (7KH&RQWUDFWRUVKDOOSURYLGHFRPSDQ\QDPHDQGSURGXFWLRQGDWH PRQWKDQG\HDU RQWKH RXWHUMDFNHWRIHDFKSLSHDQGILWWLQJ,QIRUPDWLRQVKDOOEHHQJUDYHGRQDOXPLQXPMDFNHWVZLWK LQFKWRLQFKKLJKOHWWHULQJEHWZHHQ´DQG´RIRQHHQGRIWKHMDFNHW )$OOVXUIDFHVRIWKHRXWHUMDFNHWLQFOXGLQJHQGFXWVDQGZHOGVVKDOOEHILQLVKHGVXFKWKDWQR MDJJHGHGJHVH[LVWWKDWFRXOGFDXVHSHUVRQDOLQMXU\ &LW\RI6KLVKPDUHI  +HDW5HFRYHU\3URMHFW  '(6,*1  ±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ƒ)DWWKHVWDUWRIIDEULFDWLRQ7KHIDEULFDWHGSLSHVKDOOEHSODFHGLQDIDFLOLW\PDLQWDLQHGDWD WHPSHUDWXUHRIƒ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±   ,QVXODWHG3LSHDQG)LWWLQJV %,QVXODWLRQVKDOOEHSODFHGLQWRWKHSLSHE\DVLQJOHLQMHFWLRQDSSOLFDWLRQ)LWWLQJVPD\EH PDQXIDFWXUHGXVLQJRQHLQVXODWLRQLQMHFWLRQIRUHDFKRSHQHQGRIWKHILWWLQJ,QQRFDVHVKDOO WKHMDFNHWEHGULOOHGWRSHUIRUPPRQLWRURULQVSHFWWKHLQMHFWLRQ &7KHPD[LPXPDOORZDEOHYRLGVL]HLVLQ IRUUHIHUHQFHD´[´[´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±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ƒ)IRUDPLQLPXPRIKRXUVSULRUWRWHVWLQJ G,QDGGLWLRQWRWKHWHVWLQJLGHQWLILHGLQVHFWLRQWKHIROORZLQJWHVWVVKDOOEH SHUIRUPHGWRYHULI\WKHTXDOLW\RIWKHILQLVKHGSURGXFW  &RUHSLSHLQVXODWLRQERQG D 7ZRLQFKOHQJWKVRIFXUHGLQVXODWHGSLSHVKDOOEHFXWIURPRQHXQFRDWHG LQVXODWLRQIDFHHQGRIFRPSOHWHGSLSHOHQJWK7KHUHPDLQLQJOHQJWKVKDOO EHWULPPHGDFFRUGLQJWRWKHGLPHQVLRQDOWROHUDQFHVRIWKLVVSHFLILFDWLRQ DQGFRDWHGWRDOORZ2ZQHUXVHRIWKDWSLSHVHFWLRQ E 2QHVSHFLPHQVKDOOEHWHVWHGDWƒ)7KHRWKHUVSHFLPHQVKDOOEH EURXJKWWRƒ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±   ,QVXODWHG3LSHDQG)LWWLQJV 3$57(;(&87,21 &25(3,3()86,21 $$OOIXVLRQRI335&7SLSHVKDOOEHVRFNHWIXVLRQ,IVRFNHWIXVLRQLVQRWIHDVLEOHGXHWRVSDFH FRQVWUDLQWVDWVSHFLILFMRLQWV&RQWUDFWRUVKDOOUHTXHVWDXWKRUL]DWLRQIURPWKH(QJLQHHUWRDOORZ IRUHOHFWURIXVLRQFRXSOLQJVWREHXVHG %$OOIXVLRQZHOGMRLQWVVKDOOEHPDGHLQDFFRUGDQFHZLWKWKHSLSHDQGILWWLQJPDQXIDFWXUHU¶V VSHFLILFDWLRQVDQGSURGXFWVWDQGDUGV &)XVLRQZHOGWRROLQJDQGZHOGLQJPDFKLQHVVKDOOEHDVVSHFLILHGE\WKHSLSHDQGILWWLQJV PDQXIDFWXUHU '3ULRUWRMRLQLQJWKHSLSHDQGILWWLQJVVKDOOEHSUHSDUHGLQDFFRUGDQFHZLWK$670)DQG WKHPDQXIDFWXUHU¶VVSHFLILFDWLRQV (-RLQWSUHSDUDWLRQVHWWLQJDQGDOLJQPHQWIXVLRQSURFHVVFRROLQJWLPHVDQGZRUNLQJSUHVVXUH VKDOOEHLQDFFRUGDQFHZLWKWKHSLSHDQGILWWLQJPDQXIDFWXUHU¶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±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