HomeMy WebLinkAboutSand Point Wind Monitoring Final Report - Jun 2009Results of Wind Monitoring at Sand Point 24 June, 2009 Report Outline Project Overview/Summary of Results Project Location Project Instrumentation Discussion of Wind Resource Appendix Project Overview/Summary of Results As part of the NREL Native American Anemometer Loan Program an anemometers was installed near Sand Point, Alaska to assess the area’s wind energy potential. This report describes the wind resource measured at this location. The monitoring period ran from 14 February 2004 to 6 July 2005. The measured average power density and wind speed, measured at 20m (66ft), are 424 W/m2 and 6.7 m/s (14.9 mph) respectively. This is consistent with the resource indicated by publically available wind maps. For example, the 3Tier wind map (Figure 4) (http://firstlook.3tiergroup.com/) estimates the average wind speed at the site (@ 20m AGL) at between 5.9 and 10.6 m/s. (13.1 mph – 23.6 mph) The wind data for this site was processed using three different software packages. The first is a package, referred to as the NREL Package” that has been developed at NREL for internal use. The advantage of this software package it that it provides values for the power density. The values provided by this package will be used in the main body of the report. The next package, WindPro, has been the software used to provide the interim plots during the monitoring period. Windpro provides the capability to exclude zero’s (for wind speed) when calculating the average wind speed and the analyzing the wind speed distribution. Finally, Windographer provides nice rose plots of both frequency versus wind direction and relative energy versus wind direction. The values provided by the NREL package will be used in the main body of the report, but occasionally, the Windpro and Windographer values will be provided as well. The Windpro plots are provided in the back of this report. Project Location The monitoring site is located just north of Sand Point, AK (N 55.34567 q, W 160.48832 q) at an elevation of 52m (170 ft). See Figure 1 through Figure 3. Figure 1 and Figure 2 also show the location of the reference site which provides long term wind data. This can be used to determine how closely the collected data matches the long term mean wind resource. Project Instrumentation The instrumentation consisted of an NRG Wind Explorer system. This included a cup anemometer, wind vane and data logger. The instruments were mounted at a height of 20m (66ft) on a tilt-up tubular tower. The collected data consisted of 10-minute average wind speed, including wind speed standard deviation and wind direction. 1 Figure 1: Project Location (Regional) Figure 2: Project Location (Mid Scale) 2 Figure 3: Project Location (Close Up) Figure 4: 3Tier Wind Map (Source:http://firstlook.3tiergroup.com/) 3 Discussion of Wind Resource Figure 5 summarizes the collected wind data. The values for the 50-meter wind speed and power density are conservative estimates using a wind shear factor of 0.15. The shear could well be higher in which case the average wind speed and power density (@ 50m AGL) will be higher. Average Wind Speed (m/s) Average Power Density (W/m^2) Average Annual Wind Speed & power density 6.7 m/s (14.9 mph) 424 W/m2 Average wind speed & power density for best month (December) 8.2 m/s (18.2 mph) 694 W/m2 Average wind speed & power density for worst month (July) 4.2 m/s (9.3 mph) 101 W/m2 Estimated Resource @ 50 meters 7.6 m/s (16.9 mph) 640 W/m2 Figure 5: Wind Data Summary 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 0 100 200 300 400 500 600 700 800 900 Average Wind Speed (m/s)Average Wind Power Density (Watts/m^2)Month Sand Point Monthly Wind Resource (Measured at 20 m (66 ft)) Wind Power Density Site Wind Speed Reference Site Wind Speed Figure 6: Monthly average and annual average wind power density and wind speed. 4 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 0 50 100 150 200 250 300 350 400 450 500 123456789101112131415161718192021222324 Average Wind Speed (m/s)Average Wind Power Density (Watts/m^2)Hour Sand Point Diurnal Wind Speed & Power (Measured at 20 m (66 ft)) Wind Power Density Wind Speed Figure 7: Average annual daily wind profile. Speed and Power by Month Figure 6 shows the monthly and annual average wind power density. The measured annual average power density is 424 W/m2. The measured annual average wind speed is 6.7 m/s (14.9 mph). The winter months have the greatest wind resource while the early summer has the lowest wind resource. The wind resource at this site is extremely seasonal, with the average wind speed varying by a factor of two between the summer and winter and the average power density varying by a factor four. Figure 6 also shows the long term monthly average wind speeds for the reference site. This data usually gives a better indication of how the wind resource varies by season than does the collected data. In this case the measured data broadly follows the pattern of the reference site data. Compared to the long term data, the monitoring period data shows a more pronounced difference between the summer and winter wind speeds. Both the measured data and the reference data show a mid-winter dip in the monthly average wind speeds. For the measured data this dip occurs in January compared to December for the reference data. Finally, the lowest wind speed month in the collected data is July, compared to June for the reference site data. Speed and Power by Hour Figure 7 shows the annual average diurnal (daily) profile for the site. In general the winds are highest in the mid afternoon and weakest in the very early morning. (See Appendix B for monthly profiles). Compared to most other sites examined by this author, the diurnal profile at this site is weak. Be advised it is very possible that the diurnal profile may shift with increasing height. 5 Wind Frequency Rose 0° 22.5° 45° 67.5° 90° 112.5° 135° 157.5° 180° 202.5° 225° 247.5° 270° 292.5° 315° 337.5° 2% calm 5% 10% 15% Figure 8A: Frequency by direction. Total Wind Energy (20 m) 0° 22.5° 45° 67.5° 90° 112.5° 135° 157.5° 180° 202.5° 225° 247.5° 270° 292.5° 315° 337.5° 6.67% 13.3% 20% Figure 8B: Energy by direction. 6 Figure 8C: Reference Site frequency and mean wind speed by direction Frequency and Speed by Direction Both Figure 8A and 8B show the prevailing & energetic winds coming from the NNE and the west. The most energetic winds come from NNE, with secondary peaks from the west and SSW. However, Figure 8C, which shows the frequency and mean wind speed rose for the long term reference site data, indicates that a significant portion of the winds come from the quadrant 270 – 360 degrees, (west – north). The lack of wind from this quadrant in the measured wind data is noteworthy to the NREL meteorologist who reviewed this report. A possible explanation for this observation is that the anemometer had poor exposure (for whatever reason) to the winds coming from this direction. Frequency of Speed and Percent of Power by Speed Figure 9 shows the annual frequency distribution of wind speed and power density. The line labeled PCTs shows the fraction of time that the wind falls within the specified bin. The line labeled PCTp shows the fraction of total annual energy contributed by winds of the indicated wind speed bin. On an annual basis, while over half of the time the wind speed is between 2 m/s and 9 m/s (61%), most of the wind energy is from winds with wind speeds from 7 to 15 m/s (64%). (See Appendix B). The percentage of calms, 4.9%, while low, is a bit high for such a high wind speed site such as this one. This could be due to the strong seasonal wind profile of this site, with very strong fall, winter, & spring winds and light summer winds. The best fit weibull distribution parameters for the measured data are k = 1.8 and c = 7.6. The k value indicates how widely the winds are distributed. The weibull k value of this site, at less than 2, is more typical of a continental inland site, than a coastal site such as this one. A possible explanation for the unusually low Weibull is the strong seasonal wind profile at this site. 7 0.0 2.0 4.0 6.0 8.0 10.0 12.0 012345678910111213141516171819202122232425Percent (%)Wind Speed (m/s) Sand Point Wind Speed Distribution (Measured at 20 m (66 ft)) PCTs PCTp Figure 9: Annual wind and wind energy distribution. 8 Comparison of anemometer data with long term average data An important consideration is the closeness with which the measured data reflects the long-term (multi-year) average wind resource. In other words, does the monitoring period data reflect a good year, a bad year or an average year? To answer this question long term data from a nearby reference site, Sand Point, was examined. For this site the multi year average wind speed was compared to the wind speed during the monitoring period. The results are given in the table and graph below. 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 0 1 2 3 4 5 6 7 8 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Average RationoflongtemwindspeedormonitoringperiodwindspeedAverageWindSpeed(m/s)SandPoint MonitoringPeriod&LongTerm WindData MonitoringPeriod Average Ratio Figure 11: Comparison of long term data with monitoring period data Figure 11 and Figure 12 show the monitoring period average wind speed compared to the long-term mean wind speed at the reference site. The data shows that during the monitoring period winds were higher than normal in the fall and winter and lower than normal in the spring and summer. The ratio of 1.03 indicates that overall, the monitoring period wind speeds at the reference station were slightly higher than the long-term mean wind speeds, however the difference is small (< 5%) This gives evidence that in general, the winds during the monitoring period are representative of the long term mean wind resource. Lat Long Monitoring Period Long Term Ratio Sand Point 55.32 160.53 5.06 4.91 1.03 Monitoring Site 55.35 160.49 Figure 12: Long term versus monitoring period wind data for reference stations. 9 Appendix A: Wind Data in Tabular Form Table A1: Monthly average and annual average wind power density and wind speed. Month Wind Speed (monitoring site) (m/s) Wind Power (monitoring site) (W/m^2) Wind Speed (Reference Site) (Long Term) (m/s) Jan 6.4 448 5.4 Feb 8.0 681 5.7 Mar 8.1 642 5.1 Apr 7.0 431 4.3 May 6.2 256 3.8 Jun 5.3 170 3.6 Jul 4.2 101 4.1 Aug 5.0 198 4.9 Sep 6.3 316 5.8 Oct 7.5 458 6.4 Nov 8.3 692 5.7 Dec 8.2 694 4.3 Average 6.7 424 4.9 Table A2: Average annual daily wind profile. Hour Wind Speed (m/s) Wind Power (W/m^2) 16.5 26.5 36.4 46.4 56.4 66.4 76.3 86.4 96.5 10 6.6 418 11 6.7 429 12 6.8 421 13 7.0 440 14 7.2 439 15 7.3 460 16 7.4 482 17 7.3 462 18 7.1 433 19 6.9 419 20 6.8 406 21 6.7 398 22 6.6 410 23 6.5 404 24 6.5 392 393 388 379 382 395 398 387 401 431 10 Table A3: Frequency and Energy by direction. F% %Pwr Calm 4.9 22.5 11.3 19.3 45 7.7 9.3 67.5 6.2 4.6 90 5.8 3.4 112.5 5.2 2.2 135 4.6 2.5 157.5 6.9 4.3 180 8.8 9.8 202.5 7.1 10.1 225 5.4 3.5 247.5 7.5 10.6 270 10.2 16.7 292.5 2.3 1.3 315 2.0 0.4 337.5 1.7 0.3 360 2.6 1.6 Table A4: Annual wind and wind energy distribution. Wind Speed (m/s)PCTs PCTp 04.9 16.2 27.6 39.1 48.6 510.3 69.6 78.5 87.4 96.1 10 4.9 9.2 11 3.8 8.1 12 3.0 7.6 13 2.4 7.0 14 2.0 7.1 15 1.4 5.2 16 1.5 5.0 17 0.7 4.0 18 0.4 2.8 19 0.3 1.8 20 0.2 1.5 21 0.1 1.0 22 0.1 0.6 23 0.0 0.4 24 0.0 0.3 25 0.0 0.2 0.0 0.0 0.3 0.9 2.0 3.6 5.5 7.1 8.8 9.0 11 Appendix B: Interpretation of the Wind Data Charts Introduction This appendix is a guide to interpreting the wind data charts included in the report. Included are background information and an explanation of the meaning of the data in each chart. The annual results given in the charts in this appendix will differ somewhat from the results given in the charts in the main body of the report. This is due to differences in how the data is processed. This is best described by using an example. Let us assume that 15 months of data was collected from a site, with the monitoring period running from 1 January 2003 to 31 March 2004. The annual average numbers given in the appendix simply provide the average of all the data collected. However this double counts the months of January, February & March. If these months tend to be windier than the rest of the year, then the wind resource will be over estimated. The proper procedure is to average together the data from the double counted months before averaging the data to create annual averages. This is what has been done for the charts in the main body of the report. The reason the software does not do this is that it was really designed to process multiyear data. If 9.5 years of data are processed, having 10 Januarys and 9 Julys creates negligible error. However, with only a little over a year of data, the double counted months can cause noticeable error. Power Density versus Wind Speed Wind turbines convert the kinetic energy of moving air into useful mechanical or electrical energy. The power of a column of moving air is given by the equation below. P = 0.5UAv3 (Equation B - 1) Where P = power in a column of air (watts) U = density of air (kg/m3) (Roughly ~ 1 kg/m3) A = cross sectional area of the column of air (m2) v = velocity of the air (m/s) Thus the power a wind turbine can extract from the wind is proportional to the cross sectional area of the rotor, the density of the air, and the cube of the wind velocity. At a given location the air density typically doesn’t change by more than 10%. Therefore the big variable is the wind speed. Annual average wind turbine production is very sensitive to the annual average wind speed. A wind turbine cannot extract all the energy from the air stream moving past it. A wind turbine’s extraction efficiency typically varies with wind speed. In their range of maximum conversion efficiency most of today’s wind turbines extract about 40% - 50 % of the wind’s energy. Power density is simply the power divided by the cross sectional area. Power density is given in units of watts per meter squared. (watts/m2) Power Density = 0.5Uv3 (Equation B - 2) The cubic dependence of wind power density upon velocity underscores the importance of accurately characterizing the wind at a given location. A small uncertainty in wind speed translates to a large uncertainty in wind turbine power production. For example a 5% uncertainty in wind speed leads to a 15% uncertainty in power output. The cubic relationship also makes it more difficult to predict the long-term performance of a wind turbine. More information is needed than simply the average wind speed. For example, imagine a location where the wind speed is a constant five meters per second. The average power density of a column of air with a 1m^2 cross section is then 0.5 * 1.0 kg/m3 * 1.0 m2 * 5 (m/s)3 = 62.5 watts. Over a year the total energy of that column would be 547.5 kWh (this is found by multiplying the average power density by the number of hours in a year, then dividing by 1000 to convert to kilowatts). Now imagine a location where half the time the wind speed is 3 m/s and the other 12 half the time the wind speed is 7 m/s. The average wind speed is still 5 m/s but the average power density is now 0.5*1.0*1.0*(33 + 73)/2 = 92.5 watts. This leads to an annual energy of 810 kWh. Power density is listed in many of the graphs below because power density gives a better indication of wind turbine production than does wind speed alone. As can be seen from the graph titled “Speed and Power by Month,” power density correlates to wind speed, but doesn’t follow wind speed exactly. Wind Speeds/Wind Directions These first plots simply show the wind speed and direction for the monitoring period. Good data is shown with a solid line. Bad data is shown with a dotted line. Speed and Power by Month This graph gives the average wind speed and average power density for each month. This shows how the wind resource is distributed throughout the year. Observations by Month This graph shows the number of observations for each month. The greater the number of observations, the greater the probability the data is close to the long-term average resource. Speed and Power by Hour The top graph shows how the wind speeds and power densities are distributed by time of day over the whole year. The other 12 graphs show the same thing for each month. On top of each graph is an average wind speed and power density for the period in question. Frequency and Speed by Direction These graphs show how the winds are distributed by direction. The solid line shows the fraction of time that the wind comes from a particular direction. The dotted line shows the average wind speed of the winds coming from a particular direction. Above each graph the fraction of time that the wind is calm (below 1.0 m/s) is given. These graphs indicate the directions from which the strongest winds come. Special care should be taken to ensure the wind turbines have good exposure to winds from these directions. Frequency of Speed and Percent of Power by Speed These graphs show the distribution of wind speeds and power densities. The solid line indicates the fraction of time that the wind has a particular velocity. The solid line indicates the fraction of the total wind power contributed by winds at each wind speed. 13 Appendix C: Wind Data Graphs NREL Software Package 14 0 5 10 15 20 25 30 35 40 0 50 100 150 200 250 300 350 Julian Days Station 000291 Sand Point 20m - Wind Speeds - 2004 Fri Apr 17 10:55:23 2009WS1 0 5 10 15 20 25 30 35 40 0 50 100 150 200 250 300 350 Julian Days Station 000291 Sand Point 20m - Wind Speeds - 2005 Fri Apr 17 10:55:23 2009WS1 0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350 Julian Days Station 000291 Sand Point 20m - Wind Directions - 2004 Fri Apr 17 10:55:33 2009WS1 0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350 Julian Days Station 000291 Sand Point 20m - Wind Directions - 2005 Fri Apr 17 10:55:33 2009WS1 15 Appendix D: Wind Data Graphs WindPro WindPRO version 2.4.0.62 Apr 2004 WindPRO is developed by EMD International A/S, Niels Jernesvej 10, DK-9220 Aalborg Ø, Tlf. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk Project: Sand Point - TDX Description: Data from file(s) Y:\5000\shared\Anemometer_Loan_Programs\WPA.NA.Loans\Sand Point - AK\wind data\Sand Point 040315.N04 Y:\5000\shared\Anemometer_Loan_Programs\WPA.NA.Loans\Sand Point - AK\wind data\Sand Point 040214.N04 Y:\5000\shared\Anemometer_Loan_Programs\WPA.NA.Loans\Sand Point - AK\wind data\Sand Point 041015.N04 Y:\5000\shared\Anemometer_Loan_Programs\WPA.NA.Loans\Sand Point - AK\wind data\Sand Point 050223.csv Printed/Page 10/7/2005 10:47 AM / 1 Licensed user: National Renewable Energy Laboratory 1617 Cole Blvd. (MS3811) US-GOLDEN, CO 80401 +1 303-384-7027 Calculated: 10/7/2005 10:47 AM/ Meteo data report, height: 66.0 Feet Name of meteo object: Sand Point - TDX Data from: 2/14/2004 4:10 PM Data to: 7/6/2005 2:30 PM Observations: 73137 Observations per day: 144 Recovery rate: 100% day 02/04 03/04 04/04 05/04 06/04 07/04 08/04 09/04 10/04 11/04 12/04 01/05 02/05 03/05 04/05 05/05 06/05 07/05 1 (142) 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 2 (124) 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 3 144 144 144 144 144 144 144 144 144 144 (125) 144 144 (129) 144 144 144 4 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 (123) 5 144 144 144 144 144 144 144 144 144 144 144 144 144 144 (133) 144 (95) 6 144 144 144 144 144 144 144 144 144 (117) 144 144 144 144 (137) 144 (88) 7 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 8 144 144 144 144 144 144 144 144 144 144 144 144 144 (113) 144 (126) 9 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 (115) 10 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 11 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 12 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 13 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 14 (45) 144 144 144 144 144 144 144 144 144 144 144 144 144 144 (135) 144 15 144 144 144 144 144 144 144 144 (138) 144 144 144 144 144 144 (132) 144 16 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 17 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 (133) 144 18 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 19 144 144 144 144 144 144 144 144 144 144 144 144 144 (136) 144 144 144 20 144 144 144 144 144 144 144 144 144 144 144 (103) 144 144 144 144 144 21 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 22 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 (107) 23 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 24 144 144 144 144 144 144 (128) 144 144 144 144 144 144 (136) 144 144 144 25 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 26 144 144 144 144 144 144 144 144 144 144 144 (128) 144 144 144 144 (122) 27 144 144 144 144 144 144 144 144 144 144 144 (141) 144 144 144 144 144 28 144 144 144 144 144 144 144 144 144 144 144 144 144 144 (110) 144 144 29 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 30 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144 31 144 144 (126) 144 144 144 144 144 144 % (100) (100) 100 100 100 (100) (100) 100 (100) 100 (99) (98) 100 (100) (98) (99) (98) (91) WindPRO version 2.4.0.62 Apr 2004 WindPRO is developed by EMD International A/S, Niels Jernesvej 10, DK-9220 Aalborg Ø, Tlf. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk Project: Sand Point - TDX Description: Data from file(s) Y:\5000\shared\Anemometer_Loan_Programs\WPA.NA.Loans\Sand Point - AK\wind data\Sand Point 040315.N04 Y:\5000\shared\Anemometer_Loan_Programs\WPA.NA.Loans\Sand Point - AK\wind data\Sand Point 040214.N04 Y:\5000\shared\Anemometer_Loan_Programs\WPA.NA.Loans\Sand Point - AK\wind data\Sand Point 041015.N04 Y:\5000\shared\Anemometer_Loan_Programs\WPA.NA.Loans\Sand Point - AK\wind data\Sand Point 050223.csv Printed/Page 10/7/2005 10:47 AM / 2 Licensed user: National Renewable Energy Laboratory 1617 Cole Blvd. (MS3811) US-GOLDEN, CO 80401 +1 303-384-7027 Calculated: 10/7/2005 10:47 AM/ Meteo data report, height: 66.0 Feet Name of meteo object: Sand Point - TDX Monthly mean values of wind speed in m/s Month 2004 2005 mean mean of months Jan 6.5 6.5 6.5 Feb 6.5 8.9 8.0 7.7 Mar 7.8 8.5 8.1 8.1 Apr 7.2 7.0 7.1 7.1 May 5.8 6.7 6.3 6.3 Jun 5.7 5.1 5.4 5.4 Jul 4.3 4.2 4.3 4.2 Aug 5.0 5.0 5.0 Sep 6.3 6.3 6.3 Oct 7.5 7.5 7.5 Nov 8.3 8.3 8.3 Dec 8.3 8.3 8.3 mean, all data 6.6 7.0 6.8 mean of months 6.6 6.7 6.7 Wind speed [m/s]NNNWW N W W W S W SSWSSSEESE E E N ENNE25 20 15 10 5 0 25 20 15 10 5 0 25 20 15 10 5 0 2520151050 Wind speed. Height: 66.0 Feet Wind direction. Height: 66.0 Feet Hour 2423222120191817161514131211109876543210[m/s]7 6 5 4 3 2 1 0 Degrees350 300 250 200 150 100 50 0 Wind speed. Height: 66.0 Feet Wind direction. Height: 66.0 Feet Month 121110987654321[m/s]8 6 4 2 0 Degrees350 300 250 200 150 100 50 0 Wind speed 7/1/20056/1/20055/1/20054/1/20053/1/20052/1/20051/1/200512/1/200411/1/200410/1/20049/1/20048/1/20047/1/20046/1/20045/1/20044/1/20043/1/2004[m/s]25 20 15 10 5 0 Wind direction 7/1/20056/1/20055/1/20054/1/20053/1/20052/1/20051/1/200512/1/200411/1/200410/1/20049/1/20048/1/20047/1/20046/1/20045/1/20044/1/20043/1/2004[Degrees]350 300 250 200 150 100 50 0 Turbulence intensity V>4.0 m/s 7/1/20056/1/20055/1/20054/1/20053/1/20052/1/20051/1/200512/1/200411/1/200410/1/20049/1/20048/1/20047/1/20046/1/20045/1/20044/1/20043/1/2004[]0.8 0.6 0.4 0.2 0 WindPRO version 2.4.0.62 Apr 2004 WindPRO is developed by EMD International A/S, Niels Jernesvej 10, DK-9220 Aalborg Ø, Tlf. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk Project: Sand Point - TDX Description: Data from file(s) Y:\5000\shared\Anemometer_Loan_Programs\WPA.NA.Loans\Sand Point - AK\wind data\Sand Point 040315.N04 Y:\5000\shared\Anemometer_Loan_Programs\WPA.NA.Loans\Sand Point - AK\wind data\Sand Point 040214.N04 Y:\5000\shared\Anemometer_Loan_Programs\WPA.NA.Loans\Sand Point - AK\wind data\Sand Point 041015.N04 Y:\5000\shared\Anemometer_Loan_Programs\WPA.NA.Loans\Sand Point - AK\wind data\Sand Point 050223.csv Printed/Page 10/7/2005 10:47 AM / 3 Licensed user: National Renewable Energy Laboratory 1617 Cole Blvd. (MS3811) US-GOLDEN, CO 80401 +1 303-384-7027 Calculated: 10/7/2005 10:47 AM/ Meteo data report, height: 66.0 Feet Name of meteo object: Sand Point - TDX Frequency Wind speed Sum N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW 0.00 - 0.49 1,433 62 59 69 99 73 135 160 154 132 112 100 42 67 60 40 69 0.50 - 1.49 3,782 115 167 187 246 299 393 392 348 354 258 232 154 135 153 166 183 1.50 - 2.49 4,944 204 301 292 284 397 522 405 377 377 327 293 229 211 192 274 259 2.50 - 3.49 6,117 276 472 284 325 473 550 312 376 504 418 328 388 392 322 348 349 3.50 - 4.49 7,050 252 621 445 429 479 418 269 519 824 416 450 515 712 278 240 183 4.50 - 5.49 7,706 247 756 514 500 475 431 304 595 841 506 502 700 874 192 135 134 5.50 - 6.49 7,556 242 816 577 510 393 320 325 591 693 529 587 650 921 164 116 122 6.50 - 7.49 6,711 198 1,024 562 459 321 251 235 507 482 476 534 609 736 111 109 97 7.50 - 8.49 6,026 144 990 579 402 223 176 183 459 384 500 477 540 725 122 69 53 8.50 - 9.49 4,903 109 872 489 344 195 134 242 293 359 432 293 390 604 69 52 26 9.50 - 10.49 4,167 95 716 441 267 175 133 179 230 330 349 211 412 538 59 24 8 10.50 - 11.49 3,144 68 533 370 137 95 104 85 186 243 275 117 423 452 48 7 1 11.50 - 12.49 2,462 32 416 315 92 79 34 57 155 195 260 92 297 404 24 9 1 12.50 - 13.49 1,916 41 361 218 66 66 24 63 52 175 214 65 181 362 14 14 0 13.50 - 14.49 1,584 18 343 183 43 38 14 49 31 160 158 50 168 318 8 3 0 14.50 - 15.49 1,150 23 223 111 36 40 7 35 18 136 151 17 138 205 10 0 0 15.50 - 16.49 771 15 147 50 24 34 3 22 12 76 102 13 96 166 11 0 0 16.50 - 17.49 512 5 100 20 18 22 4 9 7 62 68 5 56 125 11 0 0 17.50 - 18.49 369 2 74 22 9 24 4 7 11 48 61 0 25 73 9 0 0 18.50 - 19.49 250 1 39 14 6 14 7 7 17 41 53 0 19 31 1 0 0 19.50 - 20.49 156 0 37 5 2 3 6 3 1 35 22 0 19 23 0 0 0 20.50 - 21.49 115 0 33 6 1 1 2 1 1 19 22 0 9 20 0 0 0 21.50 - 22.49 63 0 17 7 0 2 3 1 1 8 15 0 0 9 0 0 0 22.50 - 23.49 36 0 11 9 0 0 2 1 0 5 8 0 0 0 0 0 0 23.50 - 24.49 17 0 3 5 0 0 4 0 0 2 3 0 0 0 0 0 0 24.50 - 25.49 20 0 5 7 0 0 2 2 1 0 3 0 0 0 0 0 0 25.50 - 26.49 9 0 5 1 0 0 0 0 1 0 2 0 0 0 0 0 0 26.50 - 27.49 3 0 0 0 0 0 0 0 0 3 0 0 0 0 0 0 0 27.50 - 28.49 1 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 Sum 72,973 2,149 9,141 5,782 4,299 3,921 3,683 3,348 4,943 6,489 5,740 4,366 6,060 8,103 1,858 1,606 1,485 Turbulence Wind speed Sum N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW 0.00 - 0.49 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.50 - 1.49 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.50 - 2.49 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.50 - 3.49 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 3.50 - 4.49 0.152 0.154 0.141 0.143 0.140 0.145 0.169 0.176 0.191 0.167 0.140 0.136 0.132 0.145 0.153 0.149 0.149 4.50 - 5.49 0.146 0.147 0.139 0.131 0.129 0.134 0.160 0.183 0.180 0.165 0.139 0.129 0.138 0.139 0.150 0.143 0.146 5.50 - 6.49 0.148 0.147 0.137 0.136 0.130 0.135 0.157 0.178 0.182 0.168 0.135 0.143 0.142 0.140 0.148 0.140 0.167 6.50 - 7.49 0.141 0.143 0.126 0.125 0.123 0.146 0.161 0.178 0.177 0.163 0.134 0.129 0.140 0.135 0.154 0.146 0.159 7.50 - 8.49 0.138 0.137 0.124 0.124 0.119 0.131 0.159 0.182 0.177 0.165 0.127 0.128 0.135 0.136 0.148 0.145 0.153 8.50 - 9.49 0.141 0.148 0.125 0.127 0.122 0.130 0.167 0.181 0.184 0.164 0.133 0.139 0.137 0.141 0.165 0.141 0.152 9.50 - 10.49 0.136 0.128 0.121 0.123 0.117 0.134 0.157 0.173 0.174 0.162 0.125 0.126 0.132 0.136 0.155 0.129 0.144 10.50 - 11.49 0.137 0.122 0.120 0.124 0.126 0.139 0.153 0.183 0.179 0.164 0.122 0.124 0.138 0.139 0.151 0.140 0.179 11.50 - 12.49 0.134 0.117 0.121 0.117 0.122 0.132 0.148 0.181 0.172 0.156 0.120 0.128 0.136 0.141 0.146 0.137 0.108 12.50 - 13.49 0.137 0.129 0.123 0.122 0.126 0.134 0.155 0.171 0.176 0.159 0.123 0.130 0.136 0.151 0.154 0.144 13.50 - 14.49 0.136 0.116 0.122 0.118 0.134 0.131 0.164 0.176 0.180 0.150 0.119 0.134 0.141 0.148 0.163 0.136 14.50 - 15.49 0.134 0.120 0.118 0.116 0.147 0.148 0.152 0.180 0.176 0.150 0.124 0.131 0.131 0.143 0.211 15.50 - 16.49 0.132 0.119 0.114 0.115 0.143 0.142 0.157 0.172 0.177 0.144 0.118 0.119 0.134 0.141 0.164 16.50 - 17.49 0.137 0.119 0.126 0.121 0.142 0.150 0.186 0.166 0.183 0.146 0.124 0.136 0.132 0.144 0.155 17.50 - 18.49 0.135 0.133 0.122 0.108 0.121 0.151 0.151 0.173 0.177 0.147 0.118 0.128 0.147 0.157 18.50 - 19.49 0.134 0.103 0.119 0.108 0.124 0.138 0.136 0.185 0.170 0.141 0.122 0.132 0.145 0.124 19.50 - 20.49 0.132 0.123 0.107 0.124 0.125 0.165 0.177 0.181 0.135 0.118 0.128 0.150 20.50 - 21.49 0.130 0.119 0.116 0.117 0.193 0.150 0.171 0.155 0.139 0.125 0.124 0.146 21.50 - 22.49 0.126 0.122 0.110 0.102 0.156 0.159 0.145 0.134 0.118 0.144 22.50 - 23.49 0.122 0.115 0.112 0.153 0.147 0.125 0.128 23.50 - 24.49 0.136 0.110 0.139 0.155 0.131 0.137 24.50 - 25.49 0.122 0.109 0.112 0.140 0.142 0.131 0.139 25.50 - 26.49 0.114 0.105 0.117 0.116 0.135 26.50 - 27.49 0.125 0.125 27.50 - 28.49 0.106 0.106 Sum 0.141 0.141 0.127 0.126 0.126 0.137 0.160 0.179 0.180 0.162 0.129 0.132 0.137 0.141 0.153 0.143 0.155 WindPRO version 2.4.0.62 Apr 2004 WindPRO is developed by EMD International A/S, Niels Jernesvej 10, DK-9220 Aalborg Ø, Tlf. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk Project: Sand Point - TDX Description: Data from file(s) Y:\5000\shared\Anemometer_Loan_Programs\WPA.NA.Loans\Sand Point - AK\wind data\Sand Point 040315.N04 Y:\5000\shared\Anemometer_Loan_Programs\WPA.NA.Loans\Sand Point - AK\wind data\Sand Point 040214.N04 Y:\5000\shared\Anemometer_Loan_Programs\WPA.NA.Loans\Sand Point - AK\wind data\Sand Point 041015.N04 Y:\5000\shared\Anemometer_Loan_Programs\WPA.NA.Loans\Sand Point - AK\wind data\Sand Point 050223.csv Printed/Page 10/7/2005 10:47 AM / 4 Licensed user: National Renewable Energy Laboratory 1617 Cole Blvd. (MS3811) US-GOLDEN, CO 80401 +1 303-384-7027 Calculated: 10/7/2005 10:47 AM/ Meteo data report, height: 66.0 Feet Name of meteo object: Sand Point - TDX Frequency Series 0 Weibull A: 7.6 m/s k: 1.75 Vm: 6.8 m/s Wind speed 35302520151050[%]10 9 8 7 6 5 4 3 2 1 0 Frequency NNWW SWSSEENE12 % 11 % 10 % 9 % 8 % 7 % 6 % 5 % 4 % 3 % 2 % 1 % 12 %10 %8 %6 %4 %2 % Turbulence V>4.0 m/s Series 0 Wind speed 2520151050 0.15 0.14 0.13 0.12 0.11 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 0 Turbulence V>4.0 m/s NNWW SWSSEENE0.160 0.140 0.120 0.100 0.080 0.060 0.040 0.020 0.1500.1000.050 WindPRO version 2.4.0.62 Apr 2004 WindPRO is developed by EMD International A/S, Niels Jernesvej 10, DK-9220 Aalborg Ø, Tlf. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk Project: Sand Point - TDX Description: Data from file(s) Y:\5000\shared\Anemometer_Loan_Programs\WPA.NA.Loans\Sand Point - AK\wind data\Sand Point 040315.N04 Y:\5000\shared\Anemometer_Loan_Programs\WPA.NA.Loans\Sand Point - AK\wind data\Sand Point 040214.N04 Y:\5000\shared\Anemometer_Loan_Programs\WPA.NA.Loans\Sand Point - AK\wind data\Sand Point 041015.N04 Y:\5000\shared\Anemometer_Loan_Programs\WPA.NA.Loans\Sand Point - AK\wind data\Sand Point 050223.csv Printed/Page 10/7/2005 10:47 AM / 5 Licensed user: National Renewable Energy Laboratory 1617 Cole Blvd. (MS3811) US-GOLDEN, CO 80401 +1 303-384-7027 Calculated: 10/7/2005 10:47 AM/ Meteo data report, height: 66.0 Feet Name of meteo object: Sand Point - TDX Weibull Data k-parameter correction: 0.0080/m Sector A- parameter Mean wind speed k- parameter Frequency Frequency Wind shear [m/s] [m/s] [%] 0-N 6.44 5.73 1.754 2.94 2.9 0.00 1-NNE 9.29 8.23 2.082 12.53 12.5 0.00 2-NE 8.82 7.81 2.154 7.92 7.9 0.00 3-ENE 7.23 6.41 2.033 5.89 5.9 0.00 4-E 6.36 5.72 1.542 5.37 5.4 0.00 5-ESE 5.40 4.89 1.474 5.05 5.0 0.00 6-SE 6.43 5.76 1.607 4.59 4.6 0.00 7-SSE 6.88 6.10 1.944 6.77 6.8 0.00 8-S 7.36 6.64 1.510 8.89 8.9 0.00 9-SSW 8.79 7.81 1.823 7.87 7.9 0.00 10-SW 7.04 6.23 2.250 5.98 6.0 0.00 11-WSW 8.52 7.55 1.982 8.30 8.3 0.00 12-W 9.05 8.02 1.988 11.10 11.1 0.00 13-WNW 5.51 4.99 1.469 2.55 2.5 0.00 14-NW 4.42 3.98 1.531 2.20 2.2 0.00 15-NNW 3.96 3.54 1.649 2.03 2.0 0.00 mean 7.65 6.81 1.747 100.00 100.0 0.00 Frequency Total A: 7.6 m/s k: 1.75 Vm: 6.8 m/s N A: 6.4 m/s k: 1.75 Vm: 5.7 m/s NNE A: 9.3 m/s k: 2.08 Vm: 8.2 m/s NE A: 8.8 m/s k: 2.15 Vm: 7.8 m/s ENE A: 7.2 m/s k: 2.03 Vm: 6.4 m/s E A: 6.4 m/s k: 1.54 Vm: 5.7 m/s ESE A: 5.4 m/s k: 1.47 Vm: 4.9 m/s SE A: 6.4 m/s k: 1.61 Vm: 5.8 m/s SSE A: 6.9 m/s k: 1.94 Vm: 6.1 m/s S A: 7.4 m/s k: 1.51 Vm: 6.6 m/s SSW A: 8.8 m/s k: 1.82 Vm: 7.8 m/s SW A: 7.0 m/s k: 2.25 Vm: 6.2 m/s WSW A: 8.5 m/s k: 1.98 Vm: 7.6 m/s W A: 9.0 m/s k: 1.99 Vm: 8.0 m/s WNW A: 5.5 m/s k: 1.47 Vm: 5.0 m/s NW A: 4.4 m/s k: 1.53 Vm: 4.0 m/s NNW A: 4.0 m/s k: 1.65 Vm: 3.5 m/s Wind speed 23222120191817161514131211109876543210[%]19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0