HomeMy WebLinkAboutNome Pilgrim Hot Springs A Master Plan - Masters Report Universtiy of Arizona 2013 - Desneige Marie HallbertKruzgamepapilgrim hot springsKruzgamepaKruzgamepa
iii
pilgrim hot springs
A Master Plan:
Bringing together geothermal energy, history and Iñupiaq culture to create a
sustainable and economically viable eco-tourism destination to the Seward
Peninsula, Alaska.
By:
Desneige Marie Hallbert
School of Landscape Architecture and Planning
The University of Arizona
Master’s Report 2013
v
aknowledgments
Before beginning to read the following story of how the Master Plan for Pilgrim Hot Springs came to be, it is important to
fi rst acknowledge the many people that helped along the way. This was a wonderful project to commit myself to in my fi nal year
of graduate studies and the project would not have been successful had it not been for the following individuals and organizations:
The National Park Service, Alaska Regional Offi ce
Unaataq L.L.C.
Bering Straights Native Coorporation (BSNC) & Matt Ganley
Kewerak, Inc.
Amy Russell and Tom Jamgochiam, my Nome family
Alaska Center for Energy and Power & Markus Mager
Peace Corps Fellows Program & Georgia Ehlers
Master’s Report Committee:
Ron Stoltz
Dr. Margaret Livingston
Zachary Babb, AK NPS
Other wonderful professors:
Oscar Blazquez, Beth Scott, Lauri Macmillan-Johnson,
Dr. Mark Frederickson, Dr. Ryan Perkle, R. Brooks Jeffery, and Randy Gimblett
Student editor:
Mark De La Torre
My wonderful classmates:
Deryn, Libby, Charlie, James, Xi, Kexin, Beba, Christian, Cylphine, Sara, Aaron, Kevin, Yuxin, Li, Kawthar, Lauri, Kelly
My family:
My mother and father, Nina and David Hallbert
My roommates Carol Heffern, Becky Shipe, Rachel Hill, Seneca, Chuck Doris, Vin Leisel, and Bruce Phyllis
My wonderful Tucson Community: you know who you are.
vii
table of contents
ABSTRACT
INTRODUCTION
Site Context
Research Question
Goals & Objectives
Scope of Work
LITERATURE REVIEW
Cultural Landscapes
Iñupiaq Culture
Arctic Ecology in the Seward Peninsula
Geothermal Energy
Tourism
CASE REVIEWS
Hot Spring Sites
Indigenous Inspired Resorts
Agritourism
SITE ANALYSIS
Site Visit
Photographic Documentation
Existing Structures
Historic Sites
Circulation & Current Features
Geothermal Anomaly
Hydrology & Flooding
Ecology & Vegetation
Land Ownership
Existing Tourism
THE MASTER PLAN DESIGN
Design Process
Program & Concept Development
Land-use Concepts
The Program
The Final Plan
Perspectives
CONCLUSIONS
Limitations of Study
Future Research
WORKS CITED
Literature
Case Reviews
Images
ix
1
6
37
58
76
100
102
ix
abstract
Pilgrim Hot Springs is a historic landscape in northwestern Alaska on the Seward Peninsula. It is located
60 miles north of Nome, the end location of the famous Iditarod dogsled race. Once a Catholic orphanage,
today it is a hot springs soaking destination for those who know of its existence and who are able to access it.
Recently, under the ownership of Unaataq, LLC, a consortium of seven Native corporations and regional non-
profi ts, plans to renovate the site are just beginning. This master’s report assists Unaataq, LLC, in the design of
a Master Plan to reinvigorate Pilgrim Hot Springs using ecological, historical, and cultural sensitivity to drive the
design. This Master Plan uses the concept of integrating recreation, conservation, and education to create a viable
economic ecotourism base camp from which other tourism opportunities based on the Seward Peninsula can be
accessed. Pilgrim Hot Springs will provide creative options for year round human comforts and recreation, will
sustainably harvest geothermal energy to operate off the grid, and create agricultural opportunities for the resort
and the local native communities for year round consumption and economic gain. Methods for investigation
include: case reviews of existing similar projects, site visit and landscape analysis, and informal interviews.
1
introduction
The Seward Peninsula is located on the western coast of Alaska. It
projects into the Bering Sea and is located just south of the Arctic Circle.
Once part of the Bering land bridge that connected Siberia with mainland
Alaska during the Pleistocene Ice Age, it is one of the most well-known
migration routes of humans, plants and animals coming from Asia to North
America. Archeological evidence proves the existence of Iñupiaq Eskimos
on the peninsula for thousands of years. The National Park Service maintains
the Bering Land Bridge National Preserve which makes up about ¼ of the
Seward Peninsula. It is the most remote national park of the United States
and has no roads leading to it. Access is by boat, bush plane, or during
the winter months by dogsled or snowmobile. One of the most visited
sites within the preserve is Serpentine Hot Springs. The site is loved by
many including gold miners and entire Iñupiaq villages. Once considered
a training ground for shamans, the site is still used for healing purposes
by the Iñupiaq and recreationally by most other visitors. Today there is
pressure to develop the site for tourism purposes but the archeological and
geological treasures on the site make development extremely controversial.
Additionally the precious geothermal microclimate that exists would be
similarly compromised should development increase. However, the Seward
Peninsula could stand to benefi t economically from additional tourism
opportunities. Just south of Serpentine Hot Springs is Pilgrim Hot Springs.
Like Serpentine it is a historic landscape, once a Catholic orphanage and
today a hot spring soaking destination for those who know of its existence
King
Island
and who are able to access it. Recently, under the ownership
of Unaataq LLC, a consortium of seven native corporations and
regional non-profi ts, plans to renovate the site are just beginning.
If an opportunity for development were to take place at Pilgrim
rather than within a National Preserve, tourism could be placed
in the hands of the native population and could help improve the
quality of life and aim to help preserve the culture and heritage
of the Iñupiaq of the Seward Peninsula through economic
development associated with ecotourism, geothermal energy
production, and geothermal greenhouse food production while
also protecting the precious land through environmentally and
culturally sensitive design.
site context
22222222222222222222222222222222
research question
How can the development of Pilgrim Hot Springs encourage
ecotourism in the Seward Peninsula that respects Iñupiaq
culture and Pilgrim’s rich history, protects existing biotic
communities, and utilizes geothermal energy?
3
goals & objectives
The goals and objectives of the master plan are to:
1) Assist Unaataq in realizing the site’s unique potential to be an ecotourism opportunity in the arctic.
Objective: design will incorporate knowledge of the site’s history, culture, arctic biotic communities, geothermal potential, and agriculture.
2) Aim for year-round use.
Objective: design will consider all user groups, foreign and local, and consider hosting a diverse array of seasonal uses.
3) Create a sustainable campus that does not result in degradation of the environment.
Objective: the site and suggested development will utilize sustainable practices, facilitate off the grid, improve habitat, and provide jobs for local
residences.
4) Provide opportunities for cultural connection for the Iñupiaq.
Objective: design will provide space for cultural camps, artist residency opportunities, and large-scale cultural fairs.
5) Rehabilitate the site which has been benignly neglected.
Objective: address issues of illegal squatting, undesirable use and utilize historic structures and other existing structures to benefi t the site rather
than be cause for concern and legal issues.
5
scope of work
This Master’s Report proposes to assist Unaataq, LLC,
in the design of a Master Plan that aims to reinvigorate Pilgrim
Hot Springs, using its history and native cultural ties to inform
the design. It will also incorporate sustainable ways to use the
geothermal energy found on-site with the assistance of research
recently conducted at Pilgrim Hot Springs by Alaska Center for
Energy and Power (ACEP). More specifi cally, a master plan
for Pilgrim Hot Springs will highlight opportunities in the area
that can potentially bring more economic support to an area that
is rich with beauty and culture. Additionally, perspectives and
an example interpretation sign will be created in order to help
provide visual marketing tools for Unaataq LLC fundraising
events.
6
literature
review
creating a master plan for Pilgrim Hot Springs involved a
large amount of research simply because it is enveloped by so many
different layers of information. Like any cultural landscape, Pilgrim
Hot Springs has many layers of historic epochs, from prehistoric
times to the era of the Gold Rush. There were numerous owners
and users of the site and they occupied the land in many different,
and yet also similar, ways. In reviewing this work, various patterns
were revealed that were helpful in the design process. Also, this
report refers to the potential of the site as having many infl uential
variables such as the geothermal capacity, the possibility of how
Pilgrim could help preserve parts of Iñupiaq culture in the area,
and how these could be highlighted to boost the economy in the
region through ecotourism. The literature review was daunting
at fi rst until the layers were peeled back and fi nally topics began
to reveal themselves, helping make the research more organized.
Like pages in a storybook, Pilgrim’s tale can be read from the
layers of the earth that compose the modern landscape of the site:
the geomorphology, the structure of current biotic communities,
the remains of prehistoric and historic cultures, and the memories
and lives of the Iñupiaq people. The main topics include: Cultural
Landscapes, Iñupiaq Culture, Arctic Ecology, Geothermal Energy,
and Tourisms. This framework guided the Pilgrim Hot Spring
Master Plan design process.
7
cultural landscapes
groups of people all over the world have their own defi nitions
on what a cultural landscape is. This master’s report uses the National
Park Service’s defi nition of a cultural landscape:
A geographic area, including both cultural and natural
resources and the wildlife or domestic animals therein, associated
with a historic event, activity, or person, or exhibiting other cultural
or aesthetic values.
Within this defi nition, there are then four general types of
cultural landscapes: historic sites, historic designed landscapes, historic
vernacular landscapes, and ethnographic landscapes. Historic sites are
signifi cant because of their association with a historic event. Historic
designed landscapes are associated with a prominent landscape architect
or style of garden design. A historic vernacular landscape highlights
the evolution of a landscape by people using, living, and working the
land. Rural villages, industrial complexes, and agricultural landscapes
are examples of these. Finally, an ethnographic landscape involves the
association of natural landscape elements that have become cultural
resources used to defi ne a people’s heritage. Components of this type
of landscape are important to know; they include plant communities,
animals, subsistence and ceremonial grounds. Landscapes are
therefore more than an assemblage of geographical features. They are
multi-faceted, multi-layered, and simply put: complex. Why are they
complex? Mainly because of human interactions; our social values,
our cultural constructs, our political wiles— entire groups of people
are who they are because of the landscape. Pilgrim Hot Springs is one
such landscape that has shared an intimate relationship with humans
for quite some time. It is no wonder then, that in 1977, Pilgrim Hot
Springs was nominated and accepted into the National Register of
Historic Places. It was fi nally recognized for its many contributions to
Arctic life in rather unexpected and often contradictory ways—from pre-
historic native ties to homesteading and agriculture, gold rush days that
brought roadhouses, saloons and spas, to then undergoing a complete
transformation into a Catholic orphanage and school. Fortuitously,
each layer of human use is evidenced in remains found throughout the
320 acres of land. Today, ownership has come full circle and it is now
owned by a consortium of seven native corporations known as Unaataq,
LLC. Unaataq is appropriately named— it is the Iñupiaq word for hot
spring. It is because of this geological feature that humans have been
connected to this particular landscape and why they still continue to be.
The history of Pilgrim Hot Springs is included in this literature review
because it greatly informed the design of the master plan.
8
pilgrim hot springs timeline
Pre -1900’s1890’s 1898-19181942 1972- PresentIñupiaq LifeAgriculture1918 Infl uenza1920-1941 Catholic OrphanageWWIICurrent DevelopmentGold Rush Gold Rush
999999999999999999999999999999
reasonable to extend the same sort of connection of Pilgrim with the
Kauweamiut, the people associated with the region of the Imuruk
Basin where Pilgrim resides. They too have stories and they mention
“places where the water comes out hot” and places to “use the hot
water because it made us feel healthy” (Bland 1972). These stories
however are few and far between when compared with Shishmaref
tales of connection with Serpentine, but unlike the Kauweamiut,
Shishmaref was spared the tragic decimation of their people when
the 1918 fl u epidemic swept through the region. Perhaps this is why
so few stories survived. Before the 1918 epidemic however, another
fever prevailed at Pilgrim: gold fever.
At the turn of the century, Pilgrim was known as Kruzgamepa
and homesteaders leased their 160 acres of good farm land and
modest farmhouse to a series of people who provided for the men
of the gold rush. The original farmhouse was converted into a
roadhouse, a saloon and bathhouse were constructed, and the last
frontier saw its fi rst spa. Popular literature of that time recounts
stories of miners, gamblers, and their fancy women who arrived by
dog team from Nome or from the railroad terminus at Bunker Hill
which once existed only 15 miles away. Oddly enough, despite the
glitz and glamour associated with a saloon and roadhouse, Pilgrim
was still considered a farm as well and actually experienced a sizable
growth in that department. Discovery of gold greatly increased the
population of the area, fresh produce was in high demand, and due to
the thermal amenities existing at Pilgrim, it was a highly productive
oasis in the surrounding tundra desert. Despite the roadhouse burning
down in 1908, which coincided with the decline of the gold rush, the
homesteader fi elds and gardens continued providing and reverted into
the quietude of the pastoral. Ten years later the devastation caused by
the 1918 infl uenza epidemic, which had been particularly virulent
among the Eskimo, ushered in a new era for Pilgrim. The sizable
Catholic Mission and associated Our Lady of the Lourdes Orphanage
was constructed (Bland 1972, NRHP 1977).
according to Pilgrim Hot Springs’ Alaska Historical Survey
Record card, Pilgrim Hot Springs’ periods of signifi cance include the
turn of the century, 1918, and 1941. It is stated as signifi cant for it’s:
Natural phenomenon [hot spring], signifi cant of period after
fl u epidemic of 1918, period of mission education in Alaska, Gold Rush
period, and WWII.
Its description and signifi cant features include:
320 acres, a compound of old mission buildings and gardens located
on the only patented homestead in the interior of the Seward Peninsula,
with a constant fl ow mineral spring.
Prior to the 1900’s, little is actually known of Pilgrim’s ties to
the Iñupiaq in the area; everything is speculative. Other known hot
springs on the Seward Peninsula have signifi cant ties to particular
villages. The people of Shishmaref feel proprietorship for Serpentine
Hot Springs and have many stories that refer to the site as a shamanistic
training ground. Hot seeps at Fish River and Elim are associated
with entire villages as well, and like at Serpentine Hot Springs, there
are established customs of use for both therapeutic and recreational
purposes, as well as seasonal use patterns and habits that indicate
ancient ties between the hot waters of the peninsula and the Eskimo
people (Bland 1972). It is therefore common in the area to believe and
since time immemorial...
10
the fl u resulted in many homeless native children, and with
no orphanages available, the Kruzgamepa homestead, remaining
townsite and adjoining lands, were purchased by the Catholic
Diocese of Nome in order to build an orphanage, bringing the full
acreage to what it is today at 320 acres. Almost all of the original
farm buildings were utilized, including turning the roadhouse into
a laundry. Both on-site virgin lumber and donated lumber from a
local mining company were used to build the remaining mission
structures: the dormitory-school house; quarters for the Sisters of
Ursaline, which included an infi rmary and additional classrooms
(one of the most intact buildings at the site today); a church, which
also housed the priests and brothers, a central kitchen, and root/wine
cellar (also still standing, yet less intact than the nun’s quarters); a
complete machine shop and outbuildings; a bathhouse and bathing
ponds; barn and stables; and greenhouses. Some of the buildings
were heated with the natural hot springs and even boasted fl ush
toilets. The greenhouses took full advantage of the vital geothermal
source and were able to produce vegetables all year long. Certain
vegetables in the springtime were moved to one of seven outdoor
garden beds or “truck gardens” and were said to have produced in
abundance “7 pound turnips and 30 pound cabbages” (Bland 1972),
potatoes, peas, and all types of greens and root vegetables—more
than the mission needed. The grounds were carefully landscaped and
boasted a central rock garden where a religious shrine was erected.
Wild strawberries and native rhubarb graced the front of the church.
Water was piped from the river by a windmill to a water tower near
the nun’s quarters. Additionally the farm raised chickens, cows and
horses during the summer months for eggs, dairy, and plow hauling.
Wild game, mostly caribou at that time, and plentiful salmon runs,
as well as other types of fi sh, provided meat to be smoked and dried
for wintertime and to be sold. It was a self-contained campus and for
20 years, Pilgrim Hot Springs provided a home, including education for
religious studies as well as homemaking and vocational skills, for 100
orphans annually. The staff of priests, nuns, brothers and several native
adults averaged around 20. At one point, Pilgrim even had a post offi ce
and mining center for small placer claims still existing in the area, but in
1941, due to a decline in orphan numbers and the non-essential nature
of gold mining in the face of war (WWII), it was closed and boarded up.
Members of the Kakaruk family stayed on as caretakers to tend the fi elds
which continued to supply produce to Nome and other communities.
As many as seven trips made by bush planes to ferry produce occurred
during harvest time (Bland 1972, NRHP 1977).
A. Old Bath House
B. The cemetery
C. Abandoned tractor
D. Abandoned tricycle
11
from 1942-43, after
the defeat of the Japanese in the
Aleutians, Pilgrim saw renewed
activity when the church allowed
the mission to be used for rest and
relaxation of military troops in the
area. Unfortunately “the fi nal cadres
not only departed in haste but with
uncharacteristic abandon; with
considerable breakage and looting” (item 8 pg 1 NRHP 1977). Since
that time, Pilgrim has been leased by the church to various persons
almost entirely for agricultural purposes. The buildings have steadily
deteriorated and while still picturesque for the wondering tourist who
happens by, funds to reconstruct or stabilize the buildings would require
a hefty sum. There are many treasures to be discovered however, like
the old machine shop and its array of old-fashioned tools and farming
equipment, all still in considerably fair condition. Also on the premises
are two burial grounds, one of which is still in use and is known simply
as the “cemetery.” The other is said to be a mass grave of the infl uenza
victims and has yet to be located (Bland 1972, NRHP 1977).
In 1969, a local venture called Pilgrim Springs, Ltd. made an
attempt to develop the site as a historically oriented resort but it never
made it past initial investigations (Bland 1972). Ten years later, the
University of Alaska showed renewed interest in Pilgrim, but only
for its geothermal potential. In order to get the drilling equipment
in, an eight mile road was constructed from the Kugarak highway
and the Alaska State Department of Transportation (ADOT)
obtained a road easement from Mary’s Igloo, the village name
of the Kauweamiut native people who own the land surrounding
Pilgrim. ADOT has since abandoned that easement and current
visitors to Pilgrim Hot Springs must technically trespass. The
fi nal page of the Pilgrim Hot Springs’ section of the Historical
and Archeological Site Survey of the Seward Peninsula report
by Laurel Bland, may foreshadow Pilgrim’s future as it forms
the outline of this master’s report. Great potential still exists for
Pilgrim Hot Springs:111111111111111111111111111111111111111111111
r,ththhhhee
onnlllnlllyy
meennnnntt
hwwaaaaayyyyyyyyyyy
DOOTTT)T)T
nammmmmee
diinnnnggn
rrennennnttt
Thhhhhhee
riccccaalal
epoooooorttrrrr
ormmmmssmmmm
s ffffooorrooo
C. D.
A.B.
12
“pilgrim Hot Springs is unique to this entire report. Because of its strategic location, its status as
private property, and the natural beauty and wonder of it, seen as a lush green oasis surrounded by arctic
tundra, it may hold a key to meeting needs of the local Eskimo community as well as rational economic
development related to tourism of the interior of the Peninsula.”
13
historic preservation
since the existing buildings on the land at Pilgrim are in various
states of stability, it is important to research the various intervention
approaches available to the preservation of historic structures. Below are
the four types of techniques that would be appropriate to apply to Pilgrim’s
existing built environment taking into account that different techniques
could be more appropriate for one building over another. The type of
historic preservation to undertake is completely dependent on the building
type, its current state of disrepair, and its future use on the site.
Preservation: the maintenance of a property without signifi cant
alteration to its current condition. The historic building will maintain its
historic integrity and as much of the original fabric and features as possible.
Restoration: the process of returning a building to its condition at
a specifi c time period or often its original condition. This is an appropriate
technique when portions of a structure’s historic integrity are lost.
Reconstruction: when a historic structure needs to be rebuilt entirely
and physically in place for contextual reasons, even though it no longer
exists. This often involves research and postulation from photographs.
Rehabilitation (Adaptive use): to be used for historic buildings
needing repair, alterations, or an addition. This strategy preserves those
portions or features that convey the structure’s historical, cultural, or
architectural values while making compatible use of the property possible.
Only this option approves of assigning a new use to the historic structure or
property.
(Tyler 2009)
Above:The Church, functional but needs
structural repair.
Below:the dorm, structurally unstable, would
most likely need to be reconstructed.
111113333333333313113111131111313311313331
eds
e,wwowoooullddddldd
14
Painting entitled The Wolf Dance c. 1955-1965, ink, colored pencil,
watercolor on paper 30cm x 45 cm. Artist: James Kivetoruk Moses
15
iÑupiaq culture
understanding of humans’ connection to the landscape:
The Iñupiaq worldview
it is important to understand the Iñupiaq worldview, particularly
because this site is now once again, “owned” by the native community. The
concept of land ownership is generally a western worldview construction.
The essence of the Iñupiaq worldview does not see the landscape as
something to be owned; it is one of stewardship toward the land. Lands
are not meant to be privately possessed but instead should be held in
honor of past ancestors and for future generations—“The Iñupiaq and
their lands are inseparable, their relationship is one of kinship—Earth is
a relative” (Krupnik 2004). The Iñupiaq worldview sounds very similar
to the concept of sustainability: meeting our present day needs without
depleting the resources to meet the needs of future generations. But the
Iñupiaq understanding of sustainability goes beyond meeting “our basic
needs” and it is one of religious proportions. Being human is being part
of the earth. The earth helps people to understand who they are and how
to live.
Land, for the Iñupiaq is an entity much like a person….the Earth
itself can speak. One of the ways it has spoken and continues to narrate
Iñupiaq landscape and worldview is through the act of place naming….
Iñupiaq toponyms (or place name) and associated folktales underscore
human ties with the earth, local landscape, and destiny, providing
predictive models of what it means to be Iñupiaq (Krupnik 2004).Blueberries,Vaccinium spp, part of the arctic tundra ecosystem, are an important part of the
Iñupiaq diet providing vitamin C and iron. Harvest time: late summer.
16
storytelling, subsistence, and sustainability
place naming and storytelling are transmitted orally in the
community and are held in high regard because they protect the code of
what it means to be Iñupiaq. By giving names to places in the landscape,
these toponyms become cultural artifacts and help to carry on the
cultural ideology and share how to live in the harsh Arctic environment.
Grandparents use their grandchildren as vessels; they pour memories into
them and take them to important places in the landscape where traditions and
ceremonies were once held. Behind Pilgrim for example, are the Kigluaik
Mountains, considered an ancient marker of the Kauweramiut, where the
Eagle Wolf dance had been performed. Children of the Kauweramiut would
be expected to bring others to the ancient sites and to teach the traditions
of the Eagle Wolf dance to another. This included passing on special drum
beats, songs, and dance that have developed with the landscape over the
centuries (Ublasaun 1996, Oquilluk 1973).
At the core of the Iñupiaq worldview is the understanding that
humans are part of the earth, not separate from it and it is constantly being
molded by humans’ encounters with the earth; its weather, fl ora, fauna, and
landscape formations (Ublasaun 1996). The identity of the Iñupiaq is their
relationship with the earth. It is understood that people are interdependent
on the land and sea and that they must use these great resources wisely and
with moral understanding if life on earth is to continue.
there are legends known by many
on the Seward Peninsula that tell how the
Iñupiaq once lived care-free in a warm
environment. Then, the climate changed
drastically because of two disasters: the
fi rst, an earthquake that then caused a
volcano to erupt, the second a solar and
lunar eclipse that lasted three days. On
that third day a leader was endowed by a
shaman with ingenuity and he learned to
survive and teach his people to adapt to the
cold by observing the animals: Caribou and
foxes had fur, so he made clothes of their
skin; spiders caught their food in a web, so
he wove a net to catch fi sh; snowshoe hair
could walk on snow with their big feet, so
he made snowshoes that displaced human
weight over a large area; ants and mice
made subterranean dwellings out of plants,
so he built a subterranean home with wood,
bone, and sod (Oquilluk 1973).
17111111111111777777777771111171111171111771117711111111117111117111111111111111177111111717111711111117171177777
the concept of transformation in Iñupiaq storytelling,
where humans have ties with animals and can transform into them,
illustrated how bonded together, in an endless cycle of subsistence and
movement, humans are with animals (Ublasaun 1996, Krupnik 2004).
A story about transformation then, conveys the subsistence life-style
of the Iñupiaq, sharing how to be self-suffi cient in the Arctic and how
to survive the winter. Subsistence is hunting, fi shing, gathering, and
about using all parts of an animal; for food, clothing, and tool making.
When to engage in different subsistence activities is defi ned by the
cycle of recurring seasons thus also formulating the Iñupiaq concept
of time from which all other cultural activities, village celebrations,
religious ceremonies, and products of hunting and gathering were part
of, stem from. Trade Fairs, where tribes from all over the Seward
Peninsula and from across the Bering Sea would migrate to, were
one such yearly event where pokes (animal stomach sacs) of oil, seal,
whale, walrus and maktak (blubber), as well as Caribou and other
animal skins were traded for Russian tobacco, jade, pottery, beads,
and other furs. Often dances, athletic contests and feasts followed
(Ellanna 2004). With daily and annual life revolving around the
seasons, it is again, understood that the Iñupiaq do not see themselves
as separate from nature but a vital part of it. The use of the tundra and
sea entails responsibilities. Paramount among those responsibilities is
sharing subsistence resources with others (Chance 1990). Bonds with
family and the community are very important then, because kinship
means having a vast network of people to share food, stories, cash and
shelter with. Survival is about knowing and sharing the land. Place
thus becomes the core of what must be known in order to prosper
among the Iñupiaq (Ublasaun 1996). Place naming, storytelling, and
a subsistence life-style, help to convey the Iñupiaq core value of being
part of the earth and, in essence, what it means to be sustainable.
Designs at Pilgrim Hot Springs will be inspired by and
incorporate the Iñupiaq belief system not only because
it embodies sustainability but because its existence is
threatened:
The land has names, be it on the coast or inland, but
we are beginning to forget these names. The days are here
when we are starting to forget the names of the land, the
period of forgetting the names has already begun…
~ Davey Ningeulook. 1997 (Krupnik, 2004)
Inupiaq dancers sharing thier culture with youth who are creating a documentary
entilted “The Lost Dances” with the NPS Shared Beringian Heritage Program.
18
native issues and the “period of forgetting”
The repetitive nature
of the quote above is
to emphasize the true
severity of the situation.
The Iñupiaq have existed
on the Seaward peninsula
for centuries. Evidence
of humans crossing over
the Bering Land Bridge
and settling in the region
dates back almost 13,000
years ago according to archeological fi nds in the Bering Land
Bridge National Preserve. Unfortunately, today, there is cultural
disconnect and suicide rates are fastest growing among native
peoples (Hopfi nger 2012, Butler and Hinch 1996). The unraveling
of the Iñupiaq culture can be traced back to the early 1900’s,
where the Iñupiaq were poised at the edge of an intense cultural
shift: before increased commercial whaling depleted precious
sea mammal numbers, before the gold miners ravaged the tundra
and brought manufactured European goods and illness, before
the Caribou disappeared, and before forced Christianity replaced
traditional Iñupiaq society. Oddly this parallels the known history
of Pilgrim Hot Springs…
Because Pilgrim is surrounded by what is known as
Mary’s Igloo land, or land owned by the people of Kewarak- the
Kauweramiut, the following short history pertains only to these
people. They are said to be the tribe most likely related to the
prehistory of Pilgrim Hot Springs.
In the late 1800’s, Mary’s Igloo, a name most likely given by the
miners who visited the town, once bustled with life and had a mosaic of
building types from traditional sod-covered Iñupiaq homes, to clapboard,
tents, two churches, an inn and a hotel. Missionaries had introduced
reindeer herding to help native communities recover from caribou
disappearance and the sea mammal depletion by the whaling industry,
believing also that herding was more civilized than relying solely on
hunting,fi shing and gathering. In turn many Iñupiaq made a living off
of selling reindeer meat to mining companies and roadhouses. It was
highly frowned upon for the native herders to use their own reindeer meat
for personal consumption because herding was introduced as a purely
economic venture for the native communities to accumulate cash (Ellanna
2004, Oquilluk 1973). Similar to a Trade Fair mentioned previously, in
1914, the fi rst Reindeer Fair was held in the town, bringing together native
herders from all over the peninsula. The fair left many fi lled with hope
and relief that changing times would help keep the native community
afl oat but two years later, the fl u arrived. In a matter of days, Mary’s
Igloo was decimated. Survivors, numbed by grief and shock seeing so
many loved ones so quickly diseased, relocated the village, a common
reaction to when so many members of a village die. Mary’s Igloo split
between two locations: 14 minutes downstream to New Igloo, and the
orphans, 14 minutes upriver to Pilgrim Hot Springs (Oquilluk 1973).
The orphanage only lasted about 20 years. As New Igloo did not have
the resources for a high school, many children of this age were sent
to big cities to attend school during the 1950’s; a relatively common
practice. Communication was diffi cult between rural areas and big cities
and therefore the connection to the Iñupiaq way of life slowly began to
sever. When graduates returned, they were caught somewhere between
Western and Iñupiaq worlds. Today, this balancing act continues to be
diffi cult to manage (Chance 1990).
19
This literature review does not want to delve into the severe
problems of suicide, family violence, sexual abuse, alcoholism,
unresolved grief, mental illness and racism that have all too long
affl icted many of the native communities (Hopfi nger 2012),
but acknowledges that they do exist. Based on their history,
it is appropriate to provide a place for the Iñupiaq to gather and
remember their connection to the landscape, their ancestors, and
their culture. Pilgrim Hot Springs could be such a place to host
cultural camps where grandparents can once again pour memories
into their grandchildren and perhaps the Trade and Reindeer Fairs
could happen in turn as well.
111111111199999999999911911111119911111199111111111111119919111111919191119991999999
Untitled painting by George Aden Ahgupuk, Inupiaq artist: 1911-2001. Blanket Toss image on moosehide with pastel, 9.3 cm x 24.5 cm.
Located at the Anchorage Museum of HIstory and Art.
20
eskimo architecture, arts and crafts: A time to remember
moving away from the “time of forgetting,” the second half
of the Iñupiaq Culture section is devoted to remembering. How did
a people live in the Arctic for 13,000 years? Living in the Arctic is
no easy task. Those that do not adhere to weather warnings, respect
wildlife, or understand the landscape enough to save themselves
when they are lost, ultimately perish. Understanding how the Iñupiaq
viewed the arctic landscape and their place in it and by looking at how
the Iñupiaq survived all those years on the Seward Peninsula has great
design implications for envisioning a place that is truly sustainable,
not only because it can withstand the climate but also because it can
educated others on how to continue to live sustainably in the arctic.
There is storytelling and then there is story-living.
Eskimo architecture is about using what materials can be
found. The Seward Peninsula is mostly rolling tundra and trees only
exist along river channels, yet the ocean washes up vast amounts of
drift wood. The bones of animals, whose bodies had been carefully
consumed by entire villages allowing them to survive another winter,
not only provided food but also materials for making protective
clothing, and continued being used as door frames and wall supports.
The arctic tundra, which protects the permafrost with its extensive
array of moss and lichens, is an excellent insulator. Sod houses were
built into the ground and covered by the tundra and a family’s living
situation blended so well into the landscape that their “footprint”, to
use the vocabulary of modern day sustainable practices, was hardly
noticeable (Reinhardt 2010).
These semi-subterranean frame dwellings resembled “small
hills with protruding smoke stacks. A small skylight made of the
translucent stomach of walrus or glass was set in the apex of each sod-
covered mound—the skylight being large enough to emit light and
small enough, hopefully, to deter the raiding paws of a polar bear…”
(Ellanna and Sherrod, 2004). Surrounding the sod dwellings there were
Above: Sketch of a winter wooden
dwelling.
Below: Whale bone doorframe to an old sod
house.
212222222222221222111111111122222222222222222112222222222222222122222222222222222122222222222221122
numerous caches, both elevated with different levels for storing food at the
top, skins on the next level, and canoes at the base, and subterranean cashes
that would act like a refrigerator and keep food frozen. Also, people traveled
during the different months of the year and they would construct different
structures for the different places they went to hunt and fi sh (Ellanna
and Sherrod 2004, Reinhardt 2010). Iñupiaq dwellings are known about
through interviewing Iñupiaq elders and the archeological excavations that
followed. During an excavation in Bering Land Bridge National Preserve,
an elder, visiting his boyhood home, explained how buildings were erected
by leveling support beams, fl oor planks and other horizontal members with
the expansive horizon of the sea as a reference. Also, such architecture is
depicted in Iñupiaq art and craft (Ublasaun 1996).
Arts and crafts are important to the Iñupiaq way of life because they
enhanced a storyteller’s ability to relay the past. Today, crafts have morphed
into more than storytelling props. In order to fi t into the western model of
living, they have become an important part of the economic way of life for
the Iñupiaq and subsequently they play a key role in helping to prolong the
Iñupiaq identity. Arts and crafts from the early 1900’s share images of past
daily life, of religious healing ceremonies and traditional dances (Ublasaun
1996). There are ivory pieces that depict reindeer herding and subsistence
hunting techniques. While some of these older pieces go to museums,
including one such traveling museum coordinating by native corporation
Kawerak, Inc. called Beringia Center of Culture and Science, that travels to
the villages of the Seward Peninsula, more modern renditions are sold for
a high cost at specialty shops all over Alaska. Pilgrim could help support
Iñupiaq arts and crafts by not only selling such pieces but by providing
a place for such artwork to be made as well. Perhaps a place similar to a
native arts and crafts cooperative like the one that operates in Kotzebue,
called Sulianich Art Center, could exist at Pilgrim Hot Springs that could
also offer artist in residency programs.
Ivory carving of transformation: a human drummer with a whale tail.
By Levi Tetpon, an Inupiaq Eskimo. Price: $1,100. Due to marine mammal
protection laws it cannot be exported outside of the United States.
22
arctic ecology in the seward peninsula
it is said that the villagers in Whales, a historic Iñupiaq village
that may stand to benefi t from sustainable development at Pilgrim, can
look out across the Bering Sea and see Big Diomede Island in Russian
Territory. Twelve thousand years ago, during the Last Ice Age, water
levels were so low that Russia and Alaska were actually connected by
a land mass known as Beringia. Most archeologists agree that Beringia
is where humans fi rst passed from Asia to populate the Americas. It
was also an important migration route for animals and plants as well
(NPS BELA 2012).
The peninsula is full of biological and geological signifi cance
and shares its northern boundary with the Arctic Circle. Characterized
by below 0˚F temperatures, constant ice and snow cover, continuous
darkness in wintertime, and by a short growing season that maximizes
the continuous daylight during the summer, the arctic environment
is often viewed as a monotonous landscape. The stark lack of trees
and abundance of cryptogams (spore reproducers)compose the
carpet of tundra (vegetation composed of tall and dwarf shrub heath
and graminoid-moss) which is the dominate plant-type of the arctic
landscape. (Global Climate Change, Barbour & Billings 2000). There
are two types of characteristic soil layers in the arctic; the active
layer, which thaws during the summer months, and permafrost, which
remains permanently frozen. Tundra grows on the active layer and is
essential to the arctic ecosystem because it protects the permafrost,
helping to keep it perpetually frozen. Permafrost underlies all of the
Seward Peninsula and has a dynamic process of an annual freeze and
thaw action that makes the depth of freezing vary across the landscape.
Surface features, expressed by the range of freezing that occurs,
are described as sorted and non-sorted circles, stripes, polygons,
earth hummocks and solifl uction (water saturated active layers that
can “fl ow”) steps. Larger surface features, caused by permafrost
heaving found on the peninsula, are ice-covered hills called pingos,
Above: Here a closer look at British Soldier Lichen, Cladonia cristatella. Lichens growing in the tundra of
the far north can reach incredible ages, some anywhere from 1000 to 4500 years. It is very fragile.
Below: ACEP aerial image displaying the surface features of the land caused by the expression of freezing
patterns that occur.
232222222222323333332232323322233333223233322
and small ice mounds known as palsas. These features are what
infl uence plant distribution and soil development and what makes
the monotonous landscape look not so monotonous upon closer
inspection. In general, the presence of permafrost also implies
that decomposition, nutrient release, and material synthesis from
weather, happens very slowly (Barbour & Billings 2000). It is
because of this slow decomposition rate that the arctic ecosystem
is considered very fragile and thought to be one of the most
susceptible ecosystems to global climate change. Tundra and soils
in cold eco-regions are currently net sinks for atmospheric CO2
because it becomes frozen within the permafrost. However, if
atmospheric temperatures continue to rise, the depth of the active
layer will increase there by turning the arctic into a CO2 source
(Global Climate Change, Barbour & Billings 2000).
It is important to understand the ecology of the peninsula
in order to learn from it and begin to educate those who do not
know of its fragility. Though we cannot keep permafrost from
thawing, we can try to teach visitors to understand the connection
between human caused climate change and the effects it will have
on both the arctic and, eventually, the entire world if we do not
reduce our emissions. Any development at Pilgrim Hot Springs
should take this into consideration and aim to be a net-zero carbon
emitting design. Using geothermal energy found on site would
help to achieve such a goal.
Wild Iris, Iris setosa, blooms in abundance at Pilgrim Hot Springs late
July-early August. They are well suited to wet ditches and average soil.
Though generally considered poisonous to injest, the rootstalk boiled
and ground can be applied as as polstice to relieve pain and swelling of
topical injuries.
24
geothermal energy
what is geothermal energy?
geothermal energy is the ability to recover and utilize the
earth’s heat to benefi t humans. Geothermal energy can be located
everywhere. It is just beneath the surface of the earth; however, the
most desirable places to harness geothermal energy are those that
produce the highest temperatures closest to the surface where they
can be accessed and utilized. These resources tend to be concentrated
in regions of active or geologically young volcanoes and such is the
case with the Seward Peninsula where Pilgrim resides. The Seward
Peninsula is home to the largest maar lakes in the world, and the Lost
Jim Lava Flow formation that is only 1-2,000 years old. In addition
to Pilgrim, there are several other geothermal hot springs located
throughout the peninsula.
To understand how a geothermal system works, there are a
few key terms and concepts to understand. To start, the geothermal
gradient is the understanding that heat increases in temperature with an
increase in depth into the earth’s crust. A geothermal system is an area
of high heat that transfers heat to areas of cooler temperatures to create
uniform conditions. Volcanoes, geysers and hot springs are examples
of geothermal systems that are the visible or tangible evidence of high
heat fl owing from the earth’s interior to the cooler surface of the earth
(Dickson and Fanelli 2004, Duffi eld and Sass 2004).
A geothermal system is made up of three components: a heat
source, a reservoir, and a fl uid. The heat source can be considered either
a very high temperature (>600˚C) magmatic intrusion that has reached
shallow depths (5-10K) or a low-temperature system that follows the
geothermal gradient concept above with temperature increasing with
A schematic representation of an ideal geothermal system.
depth. The reservoir is a volume of hot permeable rocks from which
the circulating fl uids extract heat. More often than not, this reservoir
is covered by impervious rock and is connected to a surfi cial recharge
area through which the fl uid can replace or partially replace the fl uids
that escape to the surface in the form of a natural hot spring or human-
made borehole. The fl uid is generally meteoric water (long standing
water generated by precipitation) and depending on the temperature or
pressure, is either in a liquid or vapor phase. This water often carries
with it other chemicals and gas originating from the rock that the
water was heated by and is what causes the sulfur smell associated
with some hot springs for example. The mechanism underlying most
geothermal systems is governed by heat driving the convection of
fl uid (fl uid convection). Heated fl uid of lower density tends to rise and
replace colder fl uid of higher density. This concept governs how the
geothermal gradient works (Dickson and Fanelli 2004).
25
direct use:
bathing, agriculture, and heating buildings
direct use is one of the oldest and most versatile uses of
geothermal energy. Geothermal direct use involves the following:
1) swimming, bathing, and balneology (treatment of disease by
bathing, a common practice among the Iñupiaq), 2) space heating
and cooling, 3) agricultural application through greenhouse and
soil heating, and 4) Aquaculture (Lund 2009). Space heating
and cooling requires absorption machines which utilizes the heat,
instead of electricity, as the energy source. Greenhouse heating
involves either forcing the circulation of air with heat exchangers,
hot-water circulating pipes or fl oor ducts, fi nned units along
the walls and under benches, or through a combination of these
techniques. Greenhouse construction requires effective thermal
insulation and, recently, a double layer of fi lm separated by an air
space has proven to be the most effective. Heated greenhouses can
support the cultivation of vegetables and fl owers out-of-season in
colder climates like the Arctic. Aquaculture can support the year-
round production of fi sh or ‘super-foods’ like the micro-algae
spirulina, which has been proposed to solve famine in poorer
countries due to its excellent nutritional attributes (Dickson and
Fanelli 2004). At Pilgrim, all direct uses of geothermal energy
described above are applicable.
22222225252552555525225252225555255525
r
r
d
Interior image of one of Chena Hot Springs’ geothermal greenhouses.
i l ti d tl d bl l
Interior image of one of Chena H
Of the three parts of a geothermal system, only the heat
source needs to be natural. In some cases, if the natural heat
source has too low a temperature to produce steam to turn a
turbine, another liquid, with a lower boiling point, can be heated
by the natural liquid, and used to transfer heat into other forms of
energy. In order to replenish a reservoir after the heated water has
been extracted; there are ways to artifi cially re-inject previously
used water back into the geothermal heat source with injection
wells (Dickson and Fanelli 2004). Re-injection is very important
to a geothermal energy system because this is how the process
sustains itself, preventing it from drying up.
26
energy production
for centuries, geothermal energy has benefi tted humans through
the use of hot spring bathing. However, it is only in the 20th century,
that technological advances have developed a way to tap into this energy
source and use it in other ways, most importantly, to generate electricity.
Today, in the midst of declining fossil fuel reserves, increased energy
demand, and having to pay attention to publicly recognized environmental
constraints, electricity produced by geothermal energy is an extremely
likable option. The utilization and implementation of geothermal energy
has many advantages over fossil fuels: it is much less intrusive than
mining and does not involve the digging, crushing and processing of
large amounts of rock; it is usable over a wide spectrum of temperature
and volumes; and it is renewable (Duffi eld and Sass 2004). Electricity
production is usually generated with conventional steam turbines, a
binary plant operation, or combination of the two. Most likely, a
simple steam turbine operation would work best at Pilgrim and so
other system types will not be discussed here. In a conventional
steam turbine system, temperatures are required to be at least 150˚C
and must be available with either atmospheric (back-pressure) or
condensing exhausts. Atmospheric exhaust turbines are cheaper and
simpler to use because they either get steam directly from a dry steam
well, or after separation, from wet wells (the latter which would be
the case at Pilgrim). It is also possible to produce electricity in small
mobile plants in isolated areas where local resources are available
(Dickson and Fanelli 2004).
Sketch of an atmospheric exhaust geothermal power-plant. The fl ow of
geothermal fl uid is indicated in red.
Image of Chena Hot Spring Resort’s Geothermal Energy System.
27222222727777272772227772272277277722722
alaska Center for Energy and Power research
Alaska Center for Energy and Power FLIR survey image of
Pilgrim Hot Springs’ geothermal anomaly.
finally, it is important to recognize the work that has gone
into geothermal exploration at Pilgrim. Such research brought the
construction of the road to Pilgrim in 1980 and today, more research
explores the possibility of a large scale geothermal electricity plant
that would not only support a small scale resort at Pilgrim Hot Springs
but could perhaps provide energy for Nome as well. The objectives of
geothermal exploration are (Dickson and Fanelli 2004):
1. To identify geothermal phenomena.
2. To ascertain that a useful geothermal production fi eld exists.
3. To estimate the size of the resource.
4. To determine the type of geothermal fi eld.
5. To locate productive zones.
6. To determine the heat content of the fl uids that will be discharged
by the wells in the geothermal fi eld.
7. To compile a body of basic data against which the results of
future monitoring can be viewed.
8. To determine the pre-exploitation values of environmentally
sensitive parameters.
9. To acquire knowledge of any characteristics that might cause
problems during fi eld development.
Geothermal exploration currently being carried out at Pilgrim,
involves multiple drilling experiments to try and locate the reservoir. In
order to reduce land disturbance, the sites where drilling experiments
have already occurred, could be potential sites for future bathing
facilities. They have conducted a thorough site analysis using satellite
based geothermal anomaly mapping, concluded an airborne FLIR
(forward looking infrared radiometry) survey and data analysis,
carried out a shallow temperature survey, completed airborne
geophysical and ground-based resistivity surveying, and have
repaired existing wellheads (UAF 2012). Additionally, they have
produced excellent trail maps, aerial photography, and exploration
result graphs and have been more than willing to collaborate with
this Master’s Report.
Geothermal energy is considered a “clean energy” if extracted
correctly (Sorensen 2009). Small-scale geothermal resources are
capable of solving numerous local problems and raising the living
standards of small isolated communities, or perhaps could even
support an ecotourism resort dedicated to environmental protection,
Iñupiaq cultural integrity, and sustainable development.
Alaska Center for Energy and Power FLIR survey immage of
Pilgrim Hot Springs’geothermalannomaly.
28
tourism
sustainable tourism
tourism is not a new concept for Pilgrim Hot Springs. In fact,
the resort at Pilgrim Hot Springs was a favorite getaway for many of the
miners and gamblers of the 1898 Nome Gold Rush, accessed by dogsled
in winter and by fl oating boats in summer. Pilgrim Hot Springs was so
successful with these users that at one point even a post offi ce existed
there (Bland 1972). In general then, as was the case with Pilgrim’s turn of
the century history, tourism can be good for the economy. Other positive
aspects of tourism, besides economic regeneration, includes establishing
heritage and environmental preservation, creating needed infrastructure
such as small healthcare units and educational facilities, fostering cultural
communication, and building political stability (Farsanni, et al. 2012,
Buckley ed. 2004). On the downside however, because tourism occurs at the
same place where it is produced, host destinations and the local population
often note environmental degradation and cultural pollution when tourism
is not carried out successfully.
Relationship between the 12 aims and the pillars of sustainability from Making Tourism
More Sustainable-A Guide for Policy Makers by UNEP and the WTO.
to combat these commonly cited issues of tourism, sustainable
tourism attempts to incorporate the goals of sustainable development; to
design that which “meets the needs of the present without compromising
the ability of future generations to meet their needs” (Farsani et al.
2012). Sustainable tourism works to meet three goals: economic stability,
sociocultural stability, and environmental stability. It implies permanence
and therefore seeks to optimize the use of resources, including providing
for biological diversity, minimizing ecological, cultural and social impacts,
and in turn, seeks to maximize the benefi ts for conservation of natural and
cultural heritage and local communities. Sustainable tourism also implies
creating ethical and authentic experiences for tourists striving
to treat the environment, host communities and employees in an
ethical manner while providing tourists with a genuine experience
of cultural events, products, and services (Smith, Macleod, and
Robertson 2010).
Under the umbrella of sustainable tourism, this literature
review section will also look at ecotourism, indigenous tourism,
agritourism, geotourism, and various other niche tourism types.
Pilgrim Hot Springs has the potential to accommodate all or part of
each of the tourism types to be defi ned in the following pages.
29
ecotourism
ecotourism strives to conserve the environment, enhance
the lives of local communities, and educate the visitor about place. It
generally focuses on fi ve key principles: it is always nature based, it
is ecologically sustainable, and environmentally educative, locally
benefi cial, and satisfi es the tourist (Smith, Macleod, and Robertson
2010). According to Martha Honey, author of multiple ecotourism
books, ecotourism also respects local culture and supports human
rights and democratic movements. The ecotourism industry is
generally made up of three broad sectors: tour operators, eco-
lodges, and eco-tour attractions. Not only must tour operations
and attractions be owned by the local community, but there must
also be varying degrees of hospitality offered. Eco-lodges and
other facilities must use local materials, establish green building
codes, and use green energy solutions (Smith, Macleod, and
Robertson 2010, Honey 2008, Fennell 2002). Within ecotourism,
there are hard and soft path perspectives that exist on a scale
between nature-related interests and physical rigor. As mentioned
above, it is important to have varying degrees of hospitality offered
because ecotourism recognizes that the eco-tourist can vary from
either hard-core nature, dedicated to nature, mainstream nature,
or be a casual nature tourist. As characterized by Fennell in the
book Environmental Programme Planning, “hard-core” types are
generally made up of scientists and researchers or members of tours
designed for educators or people doing some sort of community
2222292292229999999999999229922299929
It is important to have varying degrees of hospitality offered to appease the array of
eco-tourist types from hard-core backpackers to the casual nature tourist.
service-related project. The dedicated nature tourists are those who
take trips to see protected areas in order to understand the local
natural and cultural history. Other nature tourists are those who travel
to unique destinations, like the Amazon River, simply for the pleasure
of having gone to an unusual place. And fi nally, the casual nature
tourists are people who participate in nature incidentally by way of
being part of a larger trip or tour group (Fennell 2002). Governing
bodies of eco-tourism destinations educate their guides and make sure
they can handle their groups before sheperding tourists to explore
potentially sensitive areas. In some cases, decisions are made about
whether or not to prohibit certain areas altogether if risk and damage
to an area is deemed too great (Buckley ed. 2004).
30
indigenous tourism
similar to ecotourism, indigenous tourism follows the same
development principles but focuses more on aspects of the indigenous
culture. The term indigenous is used to describe races of people who
are endemic or native to a destination region (Butler and Hinch 1996).
There is a growing appreciation for cultures and traditions that have
lasted through the ages. From that, the accompanying recognition is that
these resilient and dynamic cultures are fragile like the environment that
formed them, and must be protected (Smith, Macleod, and Robertson
2010). Tourism is often viewed as one of the fi rst strategies for protection
and revitalization of indigenous populations (Buckley ed. 2004, Butler
and Hinch 1996, Farsanni, et al. 2012). Local empowerment and self-
determination are integral concepts to implement in order to achieve long
term benefi ts with indigenous tourism. This is necessary because the
framework of this tourism “occurs within the context of a global tourism
industry that is dominated by non-indigenous actors” as pointed out by
Richard Butler and Tom Hinch in their book Tourism and Indigenous
People. Also, what is too often a shared past by many indigenous
cultures around the world, indigenous tourism must be managed
sensitively because many of these populations have been treated poorly.
Most colonizers, missionaries and successive governments, have come
in and taken land and tried to dilute or eradicate traditional lifestyles
by forcing western assimilation (Smith, Macleod, and Robertson 2010,
Butler and Hinch 1996). Many languages and religious traditions have
been nearly wiped out in this manner. If local populations are allowed
to manage their own tourism efforts, perhaps the loss of culture can be
reversed, so that it can be revived, and celebrated once again.
Knowing that the environment and the culture cannot be
separated, conservation of the environment and cultural traditions go
hand in hand. The aforementioned book, Tourism and Indigenous
People, uses the Four “H” system: Habitat, Heritage, History, and
Handicrafts to promote this human-land connection. These elements
are interrelated and should be at the core of any indigenous tourism
planning effort. During their stay, tourists should come to understand
the geographic setting (habitat), the ethnographic traditions (heritage),
the effects of acculturation (history), and be able to take home hand-
crafted souvenirs. Habitat is about capturing the sense of awe in a
place and can be described by fi ve elements of geography: surface
features; climate; water; wild vegetation; and soils. Heritage involves
that body of knowledge that ensured human survival within the
habitat and the beliefs and values that may have developed around
the fi ve elements of habitat. History refers to post-contact relations
between native people and Westerners and handicrafts are the trinkets
of culture that represent trade, art, and stories of a culture that are easy
to share and sell (Butler and Hinch 1996).
Graphic imaging of the Four “H” system talked
about in Tourism and Indigenous People.
h
habitat
heritage
history
handicrafts
31
agritourism
Above: WWOOFing website page where interested agri-tourists can get paired with a farm.
Below: Two WWOOFers learning about the process of making maple syrup
agriculture, in the form of agritourism, can play a key
role in linking historic land uses with the present at Pilgrim Hot
Springs. Humans depended on agriculture in the past and with the
world population growing, humans are dependent on it even more
today. The problem, however, is that the general public is largely
unaware of this issue. Agritourism seeks to address this situation as
many people are beginning to actively seek educative vacations based
on learning to farm (Sznajder, Przezborska, and Scrimgeor 2009).
The basis of Agritourism is made up of three areas of focus: service,
accommodation, and mobility (walking/biking tours, etc.) The
tourist participates in agritourism in order to familiarize themselves
with farming activities whether it is putting on boots and hauling
hay (service) or simply coming to recreate in an agricultural setting
(Sznajder, Przezborska, and Scrimgeor 2009). Similar to ecotourism
needing to have varying levels of accommodations and hospitality,
this is true for agritourism as well, which depends on having multi-
functional development. When designing for agritourism destinations,
it is important to take into account the use of space and the aesthetics
of that space. In general land use should include cropping space,
livestock, orchard and plantations, forest space and potentially fi shing
space if it does not interfere with local subsistence needs. There
must be an organization of the agricultural production space, and
well-maintained forests and trails. The food and beverage should be
exquisite and accommodations should celebrate the surrounding rural
environment (Sznajder, Przezborska, and Scrimgeor 2009).
313131331131331133311333133113333333333133331111
hhhhhhhh aaa faa fa fa ffafffa fafffaffaffa fa ffaaarmarmarmarrmarmmmarmmmmmrmmmmmmmmrmmmm........
plplplplplplplllplplpplplpplplplplplpllpplpllplppeeee se seeeyruyruyruyruyruyruyruyruruyruyruuuyruruyruuruyruyruyyrrurruyruruyruruuyrururyyppppppppppppppppppppppppppppppp
32
geotourism
for this work, it is also important to discuss the concept of
geotourism, which is a fairly new type of tourism coined in 1998 by the
World Tourism Organization (WTO). Defi ned by the WTO as:
Tourism development that meets the needs of present tourists
and host regions, while protecting and enhancing opportunities for
the future leading to management of all resources in such a way that
economic, social, and aesthetic needs can be fulfi lled while maintaining
cultural integrity, essential ecological processes, biologic diversity, and
life support systems (Farsani et al. 2012, 10-11).
Geotourism extends the principles of ecotourism beyond nature
and ecology and focuses on sharing the characteristics that contribute
to a sense of place; historic structures, traditional culture, landscapes,
cuisine, artistry, as well as fl ora and fauna. In many ways geotourism
incorporates all of the tourisms previously described and is considered
a branch all of its own of sustainable tourism, focusing on those tourists
interested in traveling to experience and learn about earth heritage; its
geology, geomorphology, geodiversity, and geography (Farsani et al.
2012). Because geotourism leans towards a niche market catering to
visitors seeking a very specifi c experience, it tends to incur less impact
on the destination environment and focuses on promoting destination
stewardship. A geotourism destination is often called a geopark.
Establishing a geopark does not affect the legal status of a property.
Federal, provincial, territorial and fi rst nation laws remain in effect.
However, such a status can encourage the local community to engage
in cultural interchange and identity preservation, while also educating
and motivating people to effectively participate in pursuing sustainable
development and a sustainable tourism that expands the concept
of sustainable living practices to its visitors through education and
demonstration (Farsani et al. 2012). This would be a fi tting tourism
model to use at Pilgrim Hot Springs.
Granite tors are a spectacular geologic formation that make the landscape around
Serpentine Hot Springs in Bering Land Bride National Preserve unique.
33
other tourisms that could be associated with
Pilgrim Hot Springs:
All of the following defi nitions are found in Key Concepts in
Tourism Studies by Smith, Macleod, and Robertson (2010):
Special Interest Tourism: traveling with the primary purpose
of practicing or enjoying a particular hobby or interest such as birding,
or watching the famous Iditarod, both of which occur near Pilgrim.
Adventure Tourism: active, passive or nostalgic engagement
with sports activities which could mean providing opportunities for
backpacking, skiing, or snowshoeing at Pilgrim.
Health and Wellness Tourism: provides opportunities for
activities and practices which contribute to personal health and
wellness, including the physical, mental, psychological and emotional
well-being of an individual. This is one of the oldest forms of tourism
and has most likely been occurring at Pilgrim since before agriculture.
Soaking has often been associated with improving health.
Heritage Tourism: virtually incorporated into the description
of indigenous tourism already, but described here as tourism focused
on historic attractions such as buildings and objects, as well as those
intangible aspects of traditional lifestyle and culture of host destination
communities. Pilgrim has no shortage of history and heritage.
Business Tourism: involves the travel and accommodation
of people attending professional events such as annual meetings,
seminars, conferences, exhibitions, trade shows and corporate retreats.
This tourism type might do well at Pilgrim.
Regeneration Tourism: typical strategies of regeneration
tourism involves developing ‘fl agship’ projects, such as cultural
attractions or events, which draw in tourism and act as catalyst
for further investment in the development of rejuvenating the
environment.
Experience Tourism: accommodates tourists who are
highly motivated to consume meaningful experiences and are
willing to pay for those “one-of-a-kind” experiences. At Pilgrim
this would be associated with the Northern Lights, the Iditarod,
and Iñupiaq trade festivals.
Dark Tourism: visits to sites associated with death, disaster,
warfare, genocide, and human suffering. This includes memorials
and burial grounds. Pilgrim has history with the 1918 fl u epidemic
with a mass burial site’s whereabouts yet to be known.
Volcano Tourism: visitors interested in seeing volcanic
processes at work or formerly active volcano sites and those natural
phenomena associated with it such as hot springs and geysers.
Finally there is also Arts Tourism which involves travel to
places hosting performing and visual arts festivals. Pilgrim could
become such a place to celebrate Iñupiaq art, performance, and
storytelling.
333333333333333333333333333333333
tioon
uraral
lyysts
thhe
aare
aare
griimm
rood,d
steer,
riaals
mmici
anniic
urrala
el tto
oululdd
annd
34
current tourism in the Seward Peninsula
“The Last Train to Nowhere” is an open-air exhibit of three steam locomotives from the 1880’s located
just outside Nome, an unrealized railroad that wanted to connect mining camps to Vancouver BC.
currently in the Arctic, there is a two-day Nome-Kotzebue
tour package that attracts 11,000 visitors each summer. According
to the book Tourism and Indigenous People mentioned above, it
is one of the most successful indigenous tours in Arctic America.
All of the four H’s are present; Inuit tour guides belonging to
a Native Coop share stories about their habitat on tundra tours
and heritage is shared through dancing and music at the Museum
of the North where arctic food of salmon, caribou and maktak
are also offered. In Nome, stories and photos focusing on the
1898 Gold Rush are shared through museum tours and outdoor
sculptures scattered throughout the town. Even the fl ight from
Nome to Kotzebue offers tourists the chance to “cross the Arctic
Circle” without having to book an extra fl ight. Photographing the
“midnight sun” is another popular activity as is seeing the aurora
borealis or northern lights during a winter visit to see the famous
Iditarod. Well-made handicrafts built from traditional materials
of baleen, ivory, bone and wood, can be found at most stores and
they often have a story about the artist attached to them (Butler
and Hinch 1996). Developing a tourism destination at Pilgrim Hot
Springs would likely collaborate well with and greatly enhance
the existing tourism economy on the Seward Peninsula.
3535353535353553
literature review summary
pilgrim Hot Springs is a cultural landscape endowed with a rich cultural history.
Each historic epoch offers design inspirations from rehabilitating the old church and
nun’s quarters to reinstating agricultural fi elds and greenhouses. The geothermal energy
found on site offers great potential for a remote development to sustain itself off the grid
and will be able to do so through all seasons. The Arctic ecosystem, though fragile, has
such magnifi cent beauty that when coupled with environmental education and low impact
development, has potential to inspire visitors to become environmental stewards. Finally,
the Iñupiaq of the Seward Peninsula have a very large part to play in the development
of Pilgrim Hot Springs. Not only must the Iñupiaq worldview become evident in the
design but the people themselves, with the guidance of Unaataq, LLC, must embrace this
place and help make it their own so that they may reinvigorate and continue to be proud
of their culture and traditions. The Iñupiaq are a people of the arctic landscape and their
ingenuity to survive in such a harsh environment for the past thousands of years should be
appreciated and celebrated by those who visit Pilgrim. Sustainable tourism encapsulates
many different types of tourism from ecotourism and indigenous tourism, to agritourism
and geotourism, and seems to provide the best framework for tourism development at
Pilgrim.
In preparing to design a future sustainable tourism development at Pilgrim,
Rasmussen and Koroleva (2003) in Social and Environmental Impacts in the North,
have a laudable list of recommendations that will help to develop Pilgrim Hot Springs
appropriately within an eco-tourism framework which also considers geotourism concepts:
1. Favor projects of small size
2. Pay attention to the site and its relation to religion and tradition
3. Involve representatives of the indigenous population and their exceptional knowledge
of the environment
4. Arrange for training of the indigenous population in their local language and culture
5. Adapt to the rhythm of salaried jobs to the seasons and local conditions so subsistence
activities can be maintained
6. Give responsibilities and margin of initiative to indigenous populations
7. Respect the values expressed by the indigenous populations
8. Have regular evaluations
design Implications
Historical inspiration for design
Restoration where possible
Educational opportunities
Design: Cultural celebration
Cultural community spaces
Educational opportunities
Low Impact Development
Educational opportunities
Maximize direct use opportunities
Possible to operate off the grid
Heat for buildings & greenhouses
Smaller size projects are good
Must be community driven
Utilize multiple tourism types
SSSSSSSSSSSSS
MMMMMMMMMMM
UUUUU
36
37
case reviews
case reviews are an important
component of design research because
they outline best management practices,
offer inspiration, clarify, and answer
design questions which then help guide
the design process. Because the project’s
location is part of the Arctic ecosystem,
the case studies are all located in or near
the Arctic.
New-born moose calf spotted
along the Kougarak highway.
38
approach
the literature review and the author’s applied design philosophy helped to formulate the following selection criteria which were developed
from the three major components of sustainability:
Environmental Stewardship, Sociocultural Equity, and Economic Viability.
sustainability
environmental
stewardship Ecosystem Sensitivity Does the project enhance the ecology of the site and support
biodiversity?
Does the project operate with renewable energy and follow
LEED building standards?
Do they grow their own food? Do guests participate?
Does the project involve the local culture and place managerial
power in their hands?
Does the project have historical signifi cance?
Does the project provide education concerning historical, cultural
and environmental elements?
Is the project economically viable?
How do you get to the site?
What is the size of the project? How many guests does it
accommodate and how?
Does the project function in all seasons and what are the
activities they provide?
Sustainable Building Design
Agricultural Practices
Indigenous Connection
Historical Connection
Educational Programming
Visitor Experience:
Accessibility
Amenities
Activities
sociocultural
equity
economic
viability
criteria questions to address
3933333999999999999939333333993393
list of case reviews
with the aid of the above selection criteria, the following case reviews were chosen and organized into three topics: Hot Spring Sites,
Indigenous Inspired resorts, and Agritourism. As there is no case study which met all of the selection criteria, in the following pages, a quick
overview of each project is provided, strengths based on the selection criteria are discussed, and notable design features are highlighted, all of
which have inspired the design of the Pilgrim Hot Springs’ Master Plan.
hot spring sites
indigenous inspired
resorts
agritourism
Chena Hot Springs, Fairbanks, Alaska
Manley Hot Springs, Alaska, USA
Tolovana Hot Springs, Alaska, USA
Liard Hot Springs, British Columbia, Canada
Blue Lagoon, Reykjavik, Iceland
Hotel Kakslauttanen, Finland
Cree Village Ecolodge, Ontario, Canada
Stepping Stone Heritage Farm
Nova Scotia, Canada
Willing Workers on Organic Farms
(WWOOF)
41
chena hot springs
location: 60 miles north of Fairbanks, Alaska
size: 450 acres
designer/management: Bernie Karl
environmental stewardship:
It appeared evident that Chena Hot Springs (CHS) is dedicated to sustainable development. It is one of the forerunners in the fi eld of
geothermal energy production for small scale facilities and is the lowest temperature geothermal resource to be used for commercial power
production in the world. It hosts numerous research operations and has an entire room dedicated to the presentation of research fi ndings. The
goal of CHS is to become a self-sustaining community. Due to its relatively remote location, the ability to produce its own geothermal energy
is half the battle. The other half is developing greater food production independence, and with the recent construction of a 4320 ft2 geothermal
heated greenhouse, they are well on their way. Able to provide their restaurant with year round fresh produce even when temperatures drop
below -56˚F, CHS is a great working example of how geothermal energy in the arctic can not only provide energy and building heat, but also
fresh produce. Opportunities for visitors to educate themselves are evidenced across the resort campus and may in fact trump proper function
and aesthetic cohesion of the campus for the visitor.44444441111114411141141444414
fieeld oofff
ppoweerrrr
s..Thhee
ennerggyy
heermaall
es droopp
uut alsooo
unnctionnn
Hydroponic tomatoes at Chena Fresh.
Right: Birds eye of Chena Hot Springs Resort.
Chena Fresh research greenhouse.
42
sociocultural equity:
Having celebrated its 100 year anniversary in 2005, CHS is proud of its centennial standing. Many a landscape sculpture representing
CHS’s gold mining past can be found on the campus holding showy perennial fl owers. Log cabins with green roofs epitomize the Alaskan
homestead aesthetic. There seems to be no known knowledge of native Athabaskan connection to the site even though the site lies within
traditional Athabaskan territory.
economic viability:
CHS operates year round. They take advantage of the long
summer nights and offer guests multiple housing options from a
rustic campground and an RV park, to a night in the hotel lodge.
In winter, the chance to soak in warm waters and see the Aurora
Borealis above brings many visitors especially from Japan. CHS
offers an array of multi-season activities from educational tours,
dog kennel visits, and the ice museum to offering seasonally specifi c
activities like hiking and ATV tours in summer and skiing and dog-
mushing in winter. Looking at the Visitor Experience table to the
right, accessibility, amenities, and activities are all very amenable
to a tourist and contribute to the resort’s economic vitality. They
also have space to host large events: the Activitiorium.
visitor experience table
accessibility amenities activities
• 60 miles of
paved road to
the site
• shuttle options
from Fairbanks
• Airstrip
• Cabins, Guest
rooms, yurts, &
campground
• Outdoor/Indoor
Hot spring pools
• Restaurant & bar
• Massage
• Activitorium
• Dog Kennels &
rides
• Ice Museum
• Hiking
• Geothermal tours
• Greenhouse tours
• Snow Coach/ma-
chine Tours
• Skiing, ice skating,
snowshoe
• Gold panning
Alaskan homestead asthetic massage therapist’s cabin. New geothermal radiant heat tubes laid for new construction. CHS’s geothermal ernergy production system.
4344444443333333344333433434434434
design implications:
CHS is the most useful case study to this master’s report because it takes the potential at Pilgrim Hot Springs for a sustainable geothermal
resort development in the Arctic and proves that such a project is possible. Chena Hot Springs is an excellent example of Environmental
Stewardship and Economic Viability and designs for the Pilgrim Hot Spring Master plan will heavily refl ect the goals of CHS to be energy self-
suffi cient, green-building design conscious, and visitor-activity-friendly. Also the concept of the hoop house for their geothermal greenhouse
is certainly one to consider since they have done quite a bit of successful geothermal greenhouse research with that particular design. Another
implication for design is looking at how every aspect of the CHS resort offers educational opportunities for the visitor to learn about geothermal
energy and various other renewable research activities happening through hosting tours of the geothermal energy production station and the
greenhouse, to providing a space for interactive research displays and hand-outs. Though CHS falls short of exploring the cultural connection
with the Athabaskan people, the subtle historic connection to gold mining found in the old tool artistic displays throughout the campus is quite
clever. They are very community-minded, however, and host large community events throughout the year that bring locals from Fairbanks
to participate in such events as the Green Energy Fair for example. They also allow for bike races that enjoy fi nishing at the Chena pools.
Designing for multiple housing options like they have at Chena is also important to consider, however placement of the different housing types
and the other land uses of the campus will be better planned learning from the shortcomings of CHS’s campus layout.
Chena Hot Springs’ natural pool and fountain. Northern lights over Chena Hot Springs Resort.
44
manley hot springs
location: 160 miles north of Fairbanks, Alaska
size: 450 acres
designer/management: Dart-AM, LLC
environmental stewardship:
The owners managing the Manley Hot Spring soaking pools (Manley Greenhouses) are a private agriculture and stone mining company dedicated
to exploring geothermal technology and utilizing a green design philosophy. Though there are no overnight visitor accommodations where the
pools are, Dart-AM has plans to build guest cabins once the farm and high tunnel geothermal greenhouses are established.
sociocultural equity:
Because the Manley Hot Spring pools are rather underdeveloped at the moment, this criterion is rather moot as is providing a Visitor Experience
Table . However, on the website of Dart-AM, LLC, they do have an extensive historic understanding of the site and information regarding their
geothermal technology research that, perhaps in the future, a historic connection and an educational component could exist there.
Iditarod Kennel located in the town of Manley Hot Springs.
Interior images of Manley Greenhouses.
4544444445555555555544545545544544445444
economic viability:
At the moment, the Darts do not publicize their pools, although wondering visitors,
who come to Manley Hot Springs to soak, can fi nd out from local businesses where the
Manley Greenhouses hot spring pools are. They must then fi nd the Darts and pay $5 to soak
for a two-hour period. Visitors know of these pools and come searching for them because
the pools are located in a greenhouse where grapes and pears grow and it is said that visitors
can pluck fruits from the vine while soaking in one of three pools!
design implications:
The high tunnel greenhouse design is similar to the CHS Hoop House design. Both
concepts offer design implications for greenhouse construction at Pilgrim. Above all, it
is the concept of placing pools within the greenhouse that is most unique and worthy of
consideration for the Pilgrim Hot Spring Master Plan.
Lodging at Manely Roadhouse.Path through one of the geothermal greenhouses. Sod house exhibit in the town of Manley Hot Springs.
46
tolovana hot springs
location: 45 air miles northwest of Fairbanks,
Alaska
designer/management: Tolovana Hot
Springs Ltd.
environmental stewardship:
The Tolovana Experience is a management philosophy at Tolovana that is dedicated to preserving the natural, rustic, and simple qualities
that the springs already possess. Their goal is to provide the visitor with low impact access and accommodations that require self-suffi ciency on
the part of the visitor so that visitors can enjoy the wilderness and help preserve the resources for future generations. Visitors are required to follow
simple rules and must make reservations in order to visit.
sociocultural equity:
There does not seem to be any mention of connections to culture or history and environmental education is garnered through the hands-
on experience of getting to the remote site, burning wood, hauling drinking water, using outhouses, and following the low-impact rules of the
Tolovana Experience.
Wooden tub at Tolovana Hot Springs.Natural pool at Tolovana Hot Springs.
4744444447777777777744747747744744447444
economic viability:
Tolovana operates through a reservation system and
because there are no roads to the site, the visitor must be self-
suffi cient and able to handle backcountry travel. Due to the small
scale of the site, intimate accommodations, and appeal to only
skilled backcountry visitor-types, this hot spring most likely does
a good job of making enough money to care for the facilities but
perhaps not enough to make a real profi t.
design implications:
Tolovana’s remote setting is similar to Pilgrim’s and offers a different perspective concerning visitor access possibilities. Also, the site
uses different tub designs: natural vs. wood (cedar), and circular vs. rectangular shapes. All of the tubs are situated so that no other tub or cabin is
visible to each other thus providing a pleasant secluded and intimate experience. How tubs are positioned and placed contributes to the feel of the
place. The feel of Tolovana Hot Springs is rustic, simple, and natural. To help reinvent Pilgrim Hot Springs’ sense of place, thoughtful placement
and design of soaking pools will be important.
visitor experience table
accessibility amenities activities
• No road access
• In summer: bush
plane or hike-in (10
miles)
• In Winter: Snow-
machine or cross-
country ski-in
• 3 rustic cabins
w/outhouses
• 3 open air
tubs
• hiking
• canoeing
• skiing
• hunting & fi shing
• birding
Skiing-in to Tolovana Hot Springs. The long pool in winter at Tolovana Hot Springs.Lodging under the Northern Lights at Tolovana Hot Springs.
48
liard hot springs
location: Mile 475 on the Alaska Highway
between Fort Nelson and Watson Lake
size: 3335 ft2
designer: Alfred Waugh
management: BC Parks: Liard River Hot
Springs Provincial Park, the Muskwa-Kechika
Management Area
environmental stewardship:
British Columbia Parks protect internationally signifi cant ecological, cultural and natural landscape features located in the province. Their
goal is to protect these areas for world class conservation, outdoor recreation, education and scientifi c study. At Liard Hot Springs, close attention
is paid to protecting the fragile muskeg (bogland) with the installation of 300 meters of wooden boardwalk that takes the visitor through the warm
water swamp and boreal forest before depositing them at the hot spring pools.
sociocultural equity:
Unlike private land-owners, provincial parks are mandated to educate the visitor about the history and cultural ties of the park.
Interpretation and education is achieved through offering guided walks and signage.
Liard Hot Springs in autumn.Liard Hot Spring pool in springtime.
49
economic viability:
Liard Hot Springs receives the heaviest use of any park
in the northern BC region and provides one of the most popular
campgrounds for travelers on the Alcan highway, serving both
regional residents and tourists. Due its popularity, Liard recieves
quite a bit of national funding and can support itself through
visitor donations, day-use and campground fees.
444444949999999999494499499994944444444944
design implications:
The characteristics of the Pilgrim and Liard hot springs are very similar in that unlike most other hot springs which fl ow directly into a
nearby river or creek, both Pilgrim and Liard have an intricate system of swamps that contribute to the unique vegetative community that thrives
at each site. Boardwalks are simple and elegant and fairly easy to maintain and would be a good option for circulation paths at Pilgrim. Also,
the park uses a zoning plan to balance protecting the environment with visitor recreation: Special Feature Zone, Intensive Recreation Zone, and
Natural Environment Zone. This is a useful planning tool that would benefi t the design of the Pilgrim Hot Spring Master Plan.
visitor experience table
accessibility amenities activities
• Accessible
from the Alcan
Highway
• 52 unit Campground
• 2 bathing pools
• Wheelchair accessible
• Playground
• Composting outhouses
• Nearby privately-owned
lodge and restaurant
• soaking
• wildlife viewing
• hiking
• biking
Boardwalks at Liard Hot Springs.Wintertime at Liard Hot Springs.A cascading waterfall at the Liard Hot Springs’ Alpha pool.
Background: changing station at Liard Hot Sprimgs.
50
blue lagoon
location: 45 minute car ride from Reykjavik,
Iceland
designer/management:
Sigriour Sigborsdottir: Basalt architects
environmental stewardship:
Blue Lagoon is 100% powered by geothermal energy and is a leading company in terms of thinking green in all aspects of their business.
The design philosophy at Blue Lagoon is termed the EcoCycle: where nature and science work in harmony, with as little environmental impact as
possible. Blue Lagoon is part of the Svartsengi Resource Park, a concept based on ecological balance, economic prosperity and social progress.
Most notably, they have been awarded the Blue Flag award, one of the most stringent environmental certifi cations based on coastal and inland
protection. The aim of the architectural design of the spa and clinic was to “protect the environment and respect its geological history. Pure
Icelandic materials from moss and stones characterize the design. We wanted to emphasize the relationship between nature and the man-made”.
sociocultural equity: Blue Lagoon offers guided history tours that also include information on the volcanic history of the area and share
stories of Icelandic folklore.
Aerial of The Blue Lagoon.A close-up of The Blue Lagoon resort and beach.
51
economic viability:
Blue Lagoon is a high-end health-related tourism
resort. They achieve high economic status because of both
their commitment to the environment and to their research and
development of the geothermal hot spring in relation to skin
ailments. They also understand how to make a place relaxing
and enjoyable to visitors and can accommodate large events
like weddings and corporate meetings.
5555551111111111155151111555555
design implications:
Blue Lagoon is a model mid-sized sustainable health-related tourisim resort. There is much to take away from their design philosophy
and attention to using only local materials that not only refl ect the local landscape but also help blend the buildings into that landscape. There is
a 200 meter footpath that cuts through lava rock and a lava rock wall that helps connect the man-made elements with the landscape. Hot Springs
are inherently about relaxation and healing and the designs at Pilgrim should aim to create that sense of peace and healing as Blue Lagoon is
able to do, even while they educate.
visitor experience table
accessibility amenities activities
• 20 min. drive
from airport
• Bus transfers
available
• Geothermal Spa
• Psoriasis Treatment Ctr
• Restaurant, Café, & Bar
• Large event space
• 15 Twin rooms
• soaking
• massages &
treatment
• Guided tour
of the history,
volcanism, &
folklore
Bridge close-up.Blut Lagoon soakers with the Svarsengi Power Plant in the
background.
Floating boardwalks at The Blue Lagoon.
Background: Soaking at The Blue Lagoon.
52
hotel kakslauttanen
location: Saariselka, Finland near Urho
Kekkonen National Park
designer/management:
Jussi Eiramo
Igloo Design help: Quantum Glass
environmental stewardship:
Kakslauttanen is committed to offering unique tourism opportunities in the remote
area of Lapland, Finland in a responsible manner. The hotel and business is designed
to make the most out of the environment whilst preserving it. All activities provided operate under a leave-no- trace policy and snowmobile use is
limited to trails in order to preserve the wilderness. They support local transportation business and use local food products. Most buildings on the
campus are built to be energy effi cient, most notable are the glass igloos which are unique to this establishment. They use effi cient radiant heat
technology that not only provides visitors with a frost-free view of northern skies and the Aurora but also keeps them comfortably warm.
sociocultural equity:
Kakslauttanen is proud of the heritage of Lapland and takes every opportunity to educate the visitor, by providing Lappish meal specialties
of reindeer, king crab, and fi sh from the Arctic Ocean in their main restaurant to offering an evening with the Sami people at the Kota restaurant
where visitors can eat and hear stories about life in Lapland and the Sami culture, from Sami people. There is also the Siida Museum dedicated to
Sami heritage which involves a guided tour to visit Lake Inari, and other holy places of the Sami people prior to visiting the museum. Kakslauttanen
also hosts the Reindeer Olympics which celebrates traditional Lappish activities from reindeer lassoing to skiing competitions. They also teach
visitors the Lappish art of berry and mushroom picking.
Glass igloos in winter-time. One of multiple lodging
opportunites at Hotel Kakslauttanen.
Close-up of a glass igloo.
53
economic viability:
Because of the remote location of Kakslauttanen,
there are many unique activities for all seasons offered
to keep visitors busy and engaged in the Lapland
landscape. There are a variety of accommodations
from traditional log cabins to snow igloos and custom-
made glass igloos so visitors are enticed to try different
sleeping arrangements. Kakslauttanen hosts the
largest smoke sauna in the world and operates year-
round. They are committed to the local economy and
enjoy economic benefi ts that enable them to build new
projects like Santa’s Resort which will now enable
them to host large conferences and concert events.
555555333333333335535333335555355
design implications:
Though not entirely dedicated to renewable energy and working to make their campus operate off the grid, there is a lot to take from Hotel
Kakslauttanen in terms of how they satisfy the Social-Cultural equity criteria avoiding repetition by not only educating visitors on the Sami and
Finnish cultures through food options, museum, and guided tours but also by taking some of their cultural design cues with the establishment
of the smoke sauna campus space, the architecture of the Kota Restaurants and the igloos. The variety of activities and sleeping arrangements
offered is key to Kakslauttanen’s economic success and consideration of what activities could be offered at Pilgrim will be an important part of
the design process.
visitor experience table
accessibility amenities activities
• Ivalo airport
35k away
• Buses to hotel
available
• 40 log cabins
• Glass & snow igloos
• Ice bar
• Smoke Sauna
• 4 Restaurants:
3 Lapishtent, 1 snow
• Husky & reindeer safaris
• Snowmobile safaris
• Guided ski treks
• Ice-fi shing
• Gold panning
• Hiking, swimming,
canoeing
• Ice carting and swimming
• Santa’s Resort
• Reindeer Olympics
• Siida Museum
• Survival Skill classes
Interior of the Kota Restaurant.A member of the Sami people in traditional dress.Souvenir shop traditional Lappish handicrafts.
54
cree village ecolodge
location: Moose Factory Island, Ontario
size: 16,000 ft2
designer: Levitt Architect Limited &
Blackwell Bowick Engineers
management: The MoCreebec First Nation
environmental stewardship:
The lodge’s design is based on traditional Cree motifs and uses all natural, non-toxic materials. It also includes many water-saving and
energy effi cient features which are important in a cold climate. From low-fl ush or composting toilets, to building with only local materials and
purchasing only natural products, the desire to have a limited impact on the land is evident at the ecolodge and it is a shining example of responsible
tourism that is accountable to the Indigenous people and the environment.
sociocultural equity:
Cree Village is the fi rst aboriginal owned and operated ecolodge in the U.S. or Canada. Wanting to bring an Indigenous perspective to
the future of tourism in the sub-Arctic region, the MoCreebec First Nation’s approach has been to refl ect positively in design and experience, the
cultural values and ethic of the Cree Nation’s past, present, and future.
Cree Village Ecolodge. A close up of the lodge with Cree motif decoration. Northern Lights over Moose Factory.
55
economic viability:
In operation since 2000, Cree Village has sought
to create a cultural hospitality and ecological experience
that establishes ecotourism as a viable example of
sustainable development for the MoCreebec people.
The community aims to make Cree Village Ecolodge a
world class facility, experience, and positive refl ection
space to celebrate cultural and biological diversity of
the natural world. Voted one of 17 Best Eco Lodges in
the World by thedailygreen.com.
design implications:
The Pilgrim Hot Spring Master plan will refl ect Iñupiaq motifs that should be apparent not only in building design but also in the layout
of the site itself. Lastly Unaataq LLC should consider creating a business model similar to what the MoCreebec Council has done at Cree Village
Ecolodge.
visitor experience table
accessibility amenities activities
• Accessible by
air, rail service,
and water taxi
• winter time: ice
road for trucks
• 20 room lodge
• 66 seat restaurant
• camping
• birding
• whale and seal watching
• CC skiing and snowshoe
• nature and river tours
• cultural tours
555555555555555555555555555555555
tttlaayouut
eeeVViillagge
ngg
oee
Welcom Sign.The boat beach where river and nature tours begin.Interior of the Ecolodge’s restaurant.
Below: Aerial of Moose Facotry Island.
56
stepping stone heritage farm
location: Waterville, Nova Scotia, Canada environmental stewardship & sociocultural equity :
Stepping Stone Heritage Farm is dedicated to organic farming, including
preserving heritage breeds of farm animals living on their land. They are small, utilize
mixed-farming techniques and prefer the use of old-fashioned approaches to agriculture
since it has worked well for them during the 70 plus years they have been operating.
Above all they are dedicated to educating visitors about where food comes from and
that the farmer has great value.
economic viability:
Stepping Stone offers a variety of stay options from a working visit to a simple
holiday farm stay. They offer a variety of amenities and due to their location, activities
on and off the farm are abundant and are very attractive to the tourist. Their motto is
“So much to do OR so little to do…it is up to you!”
design implications:
Involving tourist in farming activities at Pilgrim is not only an opportunity to
get help with the agriculture but also a chance to join Stepping Stone in the effort
to re-educate the populace on where fresh food comes from. By providing simple
accommodation and the promise of a healthy meal, tourist will be content relaxing in a
peaceful agricultural environment.
visitor experience table
accessibility amenities activities
• Accessible by
car
• located near
municipal
airport
• Comfortable rooms
with private baths
• hot-tub
• healthy meals
• farming
• hiking
• numerous museums
• golf course nearby
• skiing (in winter)
6
57
world wide opportunities on organic farms
location: All over the world
environmental stewardship &
sociocultural equity :
World Wide Opportunities on Organic Farms
(WWOOF and formerly known as Willing Workers on
Organic Farms) links volunteers and organic farmers
together in order to teach and share sustainable living
practices. Because WWOOFing happens all over the
world, volunteers are able to not only learn about farming
but about different cultures as well. WWOOFers help
plant, harvest, build greenhouses and other structures,
clear land, compost, whatever the partnering farm needs
done.
economic viability:
While there is no monetary exchange, volunteers
work a 4 to 5 hour day in exchange for comfortable
housing and three fresh meals a day, and the opportunity
to be working in a new country. The farm in return
gains substantial help on the farm which contributes to
an economic return at harvest time.
design implications:
Establishing a WWOOFing site at Pilgrim would help establish agriculture at the site and contribute to not only the education of farming
but also sustainable living. Lodging arrangements for WWOOFers would need to be considered as well as budgeting for their meals.
555757577777777777775557757777555555775755
fffff ffffffffarararararrmmimiiiimmiimmmnngggggnngggggg
WWOOFing USA website.
Notice that the Seward Peninsula has no farms participating.
Background: WWOOFing France image from vinyard trip.
58
59
site analysis
60
site visit
a crucial part of the design story...
nome, Alaska, is an hour and half commercial fl ight from
Anchorage. Summers on the Seward Peninsula are often unpredictable.
Either they are beautiful and fi lled with sunshine 24 hours a day while
others are grey, misty, and hounded by constant drizzle. The Pilgrim Hot
Spring’s visit was scheduled and planned for rain or shine. Upon arrival,
heavy clouds greeted the arriving passengers...
The following day, friends drove friends to Pilgrim Hot Springs. The
truck was painted in raindrops but after the hour long drive to the Pilgrim
Hot Springs turn off and as the vehicle wound around the hilly landscape
and descended into the valley where Pilgrim was located, the sun came out.
Two full days were spent at Pilgrim to conduct site analysis and not a
drop of rain fell. In addition to extensive photographic site documentation,
informal interviews with those living on the site or working as researchers,
were also conducted. After two days of sunshine and wildfl owers, passage
back to Nome was shared with a researcher.
Pilgrim Hot Springs is a very unique place, drawing many to either
enjoy, study, work, or plan for the site’s future. In Nome, a meeting with
one of the landowners was scheduled. Historical documents were shared,
questions answered, and a few hopes and dreams for the site were discussed.
An interview with the child of one of the orphan students unfolded in a local
diner.
This site visit was the most important part of the master’s report
design process. Without it, the sense of place would not have been
understood and the project would have been diffi cult to undertake. It could
not have happened without the help of friends new and old, the University
of Arizona’s Peace Corps Fellows Program, CAPLA, the National Park
Service, and Alaska Center for Energy and Power.
61
photographic documentation
entrance
Descending into the valley....
The cabins at
the site entrance
Ptarmigans in
the road...Tundra hills....
Abandoned at the
entrance
62
views in
The Mission Complex
Cottonwoods leading to the cemetery... The rickety hot tub...
Looking
into the
central
hot spring
pond...
63
views out
View from the pool:
The Kigluaik
Mountains
Looking north at
Hen and Chicken mountain...Hen & Chicken
Close-up
View to the
East
Hen & Chicken from the
historic windmill site...
64
seasons
Entry Gate in
autumn...
Summer looking east
Spring
Kigluaiks
Winter...looking at
the Kigluaiks
65
vegetation
Cow parsnip:
edible and
poisonous...
Crow berry: high in
pectin
Bistort:
edible
Gnarly cottonwoods
& fireweed
Beautiful
arctic
iris
Flower arrangement: Fireweed,
bluebells, cow parsnip, arctic dock
66
existing structures
because this project is looking at the possibility of turning the property into an eco-
tourism attraction, rehabilitation and a combination of reconstruction and restoration would
likely be most appropriate. There were structures that once existed, like greenhouses and
stables, which could be useful once again. If new development is necessary, it should have
a compatible design aesthetic with the existing structures and consider integrating Iñupiaq
design motifs. Utilizing these techniques and design cues, would then help in the preservation
of the entire property.
restoration, reconstruction, or rehabilitation?
Reconstruction
Restoration
Rehabilitation
Mission Complex
The Dorms The Nun’s quarters
The Red Cabins
67
historic sites
these are the sites of historic signifi cance and they will be utilized in the fi nal plan because their locations offer insight into past use of the
property, how the site could be used again in the same way, or offer what can be changed from past endeavors to make visiting the site even better.
Historic sites are a major source of inspiration for the design. Items like the windmill could be reinstated and agricultural fi elds used again. The
current pool should be improved and soaking opportunties expanded.
Possible mass grave site
Historic agricultural fi elds
Historic buildings and structures
The Church & Nun’s
Quarters
Historic Agricultural
Fields
Cemetery
Historic bath house
Current pool:
historic water tank
Historic
windmill
0 500 meters
68668668686886668668686868686886886868666868686888686688686868888888686686866868886868866668888666868686668666666666686
The former ‘Our Lady
of the Lourdes’ Mission-
Orphanage Complex
69
circulation & current features
ACEP drill
sites
Existing
structures
8 miles to the
Kougarok
Highway
then 60 miles
to Nome Existing dirt
roads
ATV-
minor trails
according to the current land management
plan, no motor vehicles will be allowed to enter
the property. If agriculture and a geothermal
energy facility were to be located on the
premise, motor vehicles to establish these uses
would need to be permitted, and future need of
agricultural equipment would need to revert to
old-fashioned techniques with horse and cart.
Most of the existing trails were
established by ATV use during geothermal
exploration. They could be used to help establish
a pedestrian trail system to accommodate future
hiking and wildlife viewing activities.
The road into Pilgrim will have to be
maintained and/or a shuttle service established
from Nome.
0 500 meters
7070
geothermal anomaly
looking at the research conducted
by Alaska Center for Energy and Power, the
geothermal anomaly, or system, present at
Pilgrim can be better understood and design
implications extracted. The images on this page
illustrate the extent of heat on the site and the
temperatures available. Where research was
conducted is also helpful to the design process
for if it is known where land was already
disturbed, as is the case with the ATV trails
that were created, designs can be generated to
work with the already disturbed land. Instead
of creating new disruption, perhaps where drill
holes were made, future hot tub pools could be
placed...
Drill sites
Current public
pool
Private pool
on-site
71
hydrology & flooding
the site has everything to do with water
from hot geothermal temperatures, to nearby
cold river water that freezes over during the
winter and fl oods in the spring. Knowing where
water tends to collect and when it does during
the year, has design implications for where
to develop or not and if so, how will fl ooding
infl uence the design of new built structures?
Water has an important presence and should
be protected, respected and celebrated by the
design.
The Pilgrim
River
0 500 meters
72
ecology & vegetation
this site has very unique botanical resources that are not found anywhere else in the region (i.e. ferns below). This is due to the hydrology
of the site and the geothermal anomaly that exists there. A riparian forest of cottonwoods snakes through the site following the water course
respectively. Wildfl owers are abundant and bring colorful biologically diverse arrangements that change with the seasons. Because the earth stays
warmer here during the winter months, wildlife can be found year-round. Looking at the larger context, vegetation diversity increases and will
offer great educational opportunities to learn about the delicate Arctic ecosystem from tussock tundra to permafrost protecting sphagnum moss,
and the wildfl owers that bring not only beauty but sustenance to humans and animals alike.anananndddddd thththththheeee wiwiwildldlflflowow
gg
aaa eee hhhhhhhhhhhhhhhhatatatatatataatatatatata bbbbbbbbbbbbbririririiriririririrngngngngngngngngngngnngngnngngnggggggggg nnnnnnnnnnnnnnnnnnnnnnnnottottotototototottototottototototttottttotooot ooooooooooooooooooooooooooooooo lllnlnlnllnlnlnlnlnlnnnlnlnlnlnnnnnlnlnlnlnnnnnnnnlnnnnnl
pp
thth lllyy
gp g ,
o humans anandd ananiimals alike..
yyy
ooo
p
auautyty bbutut ssusuusuteteenanaannnnaancnc
0 500 meters
73
land ownership
the founding members of Unaataq, LLC, are Bering Straits Native
Corporation, Kawerak, Inc., Norton Sound Development Corporation and
Sitnasuak Native Corporation (each owning a 23.08% Percentage Interest
in the Company), and Mary’s Igloo Native Corporation, Teller Native
Corporation, and White Mountain Native Corporation (each owning
a 2.56% Percentage Interest in the Company). Bering this in mind, the
above map shows Pilgrim surrounded by Mary’s Igloo land and further
surrounding land ownership shared by Mary’s Igloo and BSNC. BSNC,
as one of the chief shareholders, is also the managing member of the
property. Private land tends to be concentrated along on the Kougarok
highway. The map to the right depicts the distance relationship between
Serpentine Hot Springs and Pilgrim, showing a possible future in hot
spring tourism on the Seward Peninsula since two accessible hot spring
sites already exist in reasonably close proximity.
thf dit
884
Kilometers
00 88 16 Kilometers
747474
existing tourism
ecotourism is one of the fastest
growing segments in the tourism industry
and the Seward Peninsula, though lacking
in money, is rich in culture, history, and
natural beauty. With one of the highest
unemployment rates in Alaska at 14% and
a Native American majority of 75.2%, eco
and cultural tourism is an underutilized
WalesWWWWWWWWWWWaWaWaWaWaWaWWWWaWWaWWWWaWaWWaWaWaWWaWWWaaWaaWWWWWWWWWWWWWWWWWWWWaWWWWWWWWWWWWWWWWaWaWWWWWWaWWWWWWWWWWWWWWWWWWWWaWaWWWWWWWWWWaWWWWWWWWWWWWWaWWWaWWWWWWWWWWleleeeelellllllllelleleeeeleleleeelessssssssssssssssss
Bird-watching
Iñupiaq culture,
arts & crafts
Gold
panning
Iditarod Trail Sled Dog Race
75
The Seward Peninsula
has a lot of tourism opportunities
and because of Pilgrim’s central
location on the peninsula, Pilgrim
Hot Springs could become a leader
in sustainable tourism, a base
camp, helping to unite the many
tourism opportunities to benefi t
the larger community.
economic strategy. While the infrastructure for tourism
exists with daily fl ights to Nome from Anchorage already
operating and an extensive road system stemming from
Nome, poor marketing and lack of diversity in developed
attractions and tours hamper year round tourism potential
according to an Alaska Department of Transportation
Nome Tourism study.
ha
an
lo
H
in
ca
to
th
Gold Rush
History
Viewing the Northern
Lights
Wildlife viewing
Crossing the
Arctic Circle
Bering
Land Bridge
National
PreserveFlight -seeing
76
the master
plan design
pilgrim Hot Springs is a 320 acre property. Due to its
size, the scope of this project is to create a conceptual Master
Plan that makes suggestions for future areas of development at
the site. Also included is a detailed concept plan of the former
Our Lady of the Lourdes Mission-Orphanage complex, the title
simplifi ed and for the purposes of this Master’s Report referred
to as the Mission Complex. Nine vignettes help illustrate the
look and feel of the different areas of suggested development
and a fi nal perspective of an interpretive sign helps convey the
importance of education to this project.
Although the literature review is discussed at the
beginning of this Master’s Report, in actuality it was the site
visit that occurred fi rst and the visit that helped develop the
topics to be researched in the literature review.
Literature review research cast a wide net to help
understand the larger context of elements acting on the site
and culminated in the development of a broad list of design
implications and a list of selection criteria for selecting case
reviews.
Case review research generated inspiration and helped to
develop additional design implications at a more detailed level.
Finally site analysis, coupled with the knowledge
garnered from the literature and case reviews, took an in-depth
approach to understanding the property. What evolved from the
site analysis is a better understanding of what the property is
capable of handling and how best to propose development at the
site that will be cost-effective, ecologically sensitive, culturally
and historically driven, and educative to the future visitors to the
site that will help Pilgrim Hot Springs last into the future.
76
size
Plan
the
Our
simp
tot a
look
and
imp
begi
visit
topi
und
and
imp
revi
deve
garn
appr
site
capa
77
design process
to help convey the design process, the story bracelet,
an Iñupiaq pictographic narrative art-form, is shown here to
illustrate the story of the Pilgrim Hot Springs Master Plan
design. This bracelet exemplifi es the close relationship
between the Iñupiaq worldview and their love of storytelling
and oral tradition.
As discussed in the introduction, there are many layers
to Pilgrim Hot Springs, not only layers of history and culture,
but also layers of development potential. In the previous pages
computer generated ivory carving images of these layers have
accompanied the title pages. Similar to how a bracelet is formed
and pieced together with a single string and eventually formed
into the shape of a circle- as shown here again, the design of
Pilgrim Hot Springs is about stringing these pieces together:
the history, Iñupiaq culture, arctic ecology, geothermal energy,
tourism potential, the site analysis. The fi nal design is like a
bracelet linking these layers together to tell the next potential
story at Pilgrim Hot Springs: an ecotourism destination; a base
camp from which to access all other tourism opportunities
on the Seward Peninsula because it is centrally located. This
design, if implemented at Pilgrim Hot Springs, will help bring
a more cohesive and environmentally sensitive tourism model
to the region. It will embrace history and Iñupiaq culture, seek
always to preserve the arctic beauty of the landscape, and
fi nally, aim to educate future tourists for sharing knowledge is
the key to true sustainability.
7878778787
program &
concept development
the synthesis diagram to the left highlights the
opportunities and constraints of the site: the existing infrastructure
and circulation, hydrology, and buildable land which is based on
the ecology of the site. With these variables in mind -- in addition
to an emphasis suggesting the development of an ecotourism
destination -- recreation and conservation will be important to
integrate into the site. In many cases however, development of
a sustainable ecotourism resort pits conservation and recreation
goals against each other. In the development of an overall concept
and design philosophy for the site, interpretation was seen as a
way to help balance recreation and conservation on the site. The
above graphic demonstrates how recreation and conservation can
be balanced and integrated if they are held together by the goal
of education through interpretation. From another perspective,
imagine that a seal, an important animal to the Iñupiaq, represents
education. It has swallowed conservation and recreation and they
must coexist in the stomach of the seal and be digested together...
Circulation
Open water
Flooding
Ecology boundary
Buildable
Existing sites
0000000000000 55050005050005000000 mmmeemmmteteteeeersrsrsr
79
land-use concepts
the fi nal concept on the right is a combination of the three concepts below. While
these concepts focus on how conservation and recreation will be used on the land,
the concept of education serving as an overarching goal above the two will be
demonstrated in the fi nal design through interpretation, integration of cultural motifs,
and space programming.
1. Production-centric: This concept focuses on the production capabilities of Pilgrim:
agriculture and geothermal energy. This concept focuses on developing historic
agriculture fi elds, greenhouses, and a large geothermal energy plant that would
contribute to the Nome energy grid.
2. Eco-centric: This concept is conservation-focused leaving most of the land
undeveloped and set aside for wildlife habitat and landscape preservation areas.
Development would be concentrated where it already exists and where land is already
disturbed.
3. Recreation-centric: This concept would maximize the use of buildable land
employing a dispersed-use development structure in order to provide multiple
recreational possibilities. It would utilize all existing structures and reconstruct
where needed.
1 23
0 500 meters
80
the program
81
82
the program was developed from what
presently exists at Pilgrim (soaking), what existed in
the past (agriculture, roadhouse, school), and elements
that were successful in the case reviews (multiple
lodging options and recreational opportunities).
The compatibility matrix to the right helped
located which programmatic elements would be
appropriate near each other and which would not be
compatible. The bubble diagram on the next page
helps to illustrate the compatibility matrix and show
the relationship between the major programmatic
elements. It would be nice to have agriculture near
the restaurant that will use the produce and for the
geothermal energy plant to be near the buildings it
will supply energy to. Sleeping arrangements would
be best near food. Recreation can happen anywhere
but shares a strong relationship to geothermal energy
because of hot spring soaking. Education has a
connection to all of the major elements because, to
reiterate, education will help balance recreation and
conservation and make development at Pilgrim truly
sustainable.
838
84
the final plan
the Final Plan incorporates all of the programmatic elements and by doing so meets the goals and objectives of the Master Plan because
it addresses the three major components of Sustainability (Environmental Stewardship, Sociocultural equity, and Economic Viability) in the
following ways:
• It brings back agriculture as a land-use where it once existed and where feasible, provides lodging for agriculture volunteers, and employs both
in-ground and above ground growing options in the form of geothermal greenhouses. This allows for year-round produce production to serve
the resort needs. Any additional produce grown can then be donated or sold.
• In order to preserve as much of the land as possible for conservation and un-spoiled views, new development for recreational purposes is
concentrated where a structure either once existed or where land had been disturbed in either the distant or recent past. During all seasons,
there are multiple lodging options to satisfy different tourist types and a multitude of activities to satisfy the curious and active local and foreign
visitor. Lodging and activity options refl ect the rich history of the site and the culture of the Iñupiaq.
• The geothermal springs are utilized to bring year-round energy and heating. They are also celebrated through the provision of multiple soaking
options and by leaving the major spring located at the heart of the site un-touched—only viewing decks allow visitors the chance to watch
wildlife interact with the spring.
• The plan suggests moving the cabins located at the site entrance to the west to join the other existing cabin there. That way the entrance is made
more formal and summer leasers can enjoy a more intimate setting somewhat away from the resort. The summer leasing option helps to not
only appease the issue of illegal squatting but it can also help bring early income to the site to help fund the rest of the Master Plan.
• The plan provides several options for cultural exchange of the Iñupiaq: there is an artist in residency program cabin to support Iñupiaq artists; a
cultural demonstration area to exhibit Iñupiaq architecture and host large events; Iñupiaq design motifs are incorporated into all new structures
and Iñupiaq names are given. And fi nally, though not able to be graphically shown in the plan, it is the hope of the Master Plan that managerial
power to run the future resort will be placed in the hands of the Iñupiaq community.
• Finally the plan is infused with interpretation and education. Behind the lodge is a classroom in order to help teach ecotourism planning
to the local community and to provide additional space to host workshops and conferences if the Lodge’s community room is not enough.
Every historic site and structure will have an interpretive sign and when coupled with the trail system, tours of history, culture, ecology, and
geothermal energy will be enjoyable to program and participate in.
85
Geothermal
facilityStables
Boat BeachHen &
Chicken
hike
Kigluiak hike
Cultural demo
space
Ag volunteer
yurts
Private
Cabin
tub
Campground
tub
Summer
cabins’
tub
Helipad &
summer parking
Wildlife
viewing trails
Dog
kennels
Re-injection
well
Natural pool &
picnic area
Agriculture fi elds
& orchards
Mission
Complex
Private cabins-6
Campground-6
tent sites
Unaataq
boardwalk-4 tubs
Existing cemetery
Veiwing decks
Summer lease
cabins
a
c
b
0000 500 meters
a Entrance
86
whalebone entrance
Hen &
Chicken Mountain
Mary’s Mountain
b
welcome to Pilgrim Hot Springs’ Arctic Eco Resort! This perspective demonstrates the simple yet inviting and culturally celebratory
entrance possibility. Whale bones are traditionally used in Iñupiaq architecture and it is theorized that the experience of entering through the
whalebone door not only was practical, but spiritual, and a way of honoring the importance of whales to the livelihood of the culture. Whale
bones also signify burials and so this entrance is also fi tting for Pilgrim Hot Springs for that reason as well, honoring those who died of the
1918 infl uenza. The location of these perspectives can be found on the Master Plan (previous page) and will help orient the reader for the
perspectives in the following pages.
a
87
natural pool & picnic area
(entrance to the mission complex)
c
heading north from the whalebone entrance, the visitor will walk the dirt road towards the mission complex. They will pass beautiful
vistas, the path to Unaataq Boardwalk, the campground and the cultural demonstration space but before getting to the mission complex, the
natural beach will welcome the visitor fi rst. Day users with children can stop here for the day and over-night guests get a sneak peak at the
many soaking options available to them during their stay. Similar to the natural pool found at Chena Hot Springs, local granite rock strengthens
the edges and this pool is made unique because it boasts a simple picnic area, playground and sand beach. All materials are able to be locally
sourced, some even found on-site. An interpretive sign marks the remains of the former bathhouse.
88
the mission complex focus plan
Geothermal
facility
Stables
Greenhouses
Lodge
Hot Spring
Bath Center
Urrak Church
Restaurant
Courtyard
orchard and
gardens
Classroom
Windmill
Artist cabin
To the private
cabins
To the dog
kennels
Recreation
Center
(former Nuns’
quarters)
Ag Field
Orchard
Ag Field
Ag Field
Natural pool and
picnic area
0 10 25 50 meters
89
mission complex perspective
view of the Mission Complex from Kargi Lodge. In this perspective you can see the renovated church now acting here as a
restaurant. Food is important and should be cherished, worshiped and given thanks for; a fi tting repurposing for a church. The geothermal
greenhouses are located next door making food delivery to the restaurant quick and easy. Each salad ordered can be picked fresh or
picked by the patron themselves! To the right of the church restaurant are the renovated Hot Spring Bath Center and the artist in residence
program cabin. Children play in the courtyard, a couple strolls through the campus admiring the sculptures. A horse drawn carriage returns
from the fi elds and an old-fashioned windmill draws water from the Pilgrim River to be used by the Mission Complex.
90
greenhouses, orchard & courtyard garden
a closer look at the greenhouses
and edible courtyard garden. Visitors can
choose to either simply admire the agriculture
or get their hands dirty and participate in the
agritourism program.
91
kargi lodge & ursaline recreation center (winter)
kargi Lodge, kargi meaning
‘community house’ in Iñupiaq, is the
former dorm site. It has a cultural sculpture
garden entrance. The reconstructed Nun’s
Quarters is converted into the recreation
center where visitors can rent gear
and learn about the many recreational
opportunities offered a Pilgrim year
round. It is also where educational tours
of Pilgrim Hot Springs would begin.
The geothermal facility, stables, and dog
kennels are located just down the center
road where the horse-drawn snow carrier
is heading...
92
private tuviq stilt cabins
here, a view of the private cabins shows how these buildings deal with fl ooding by being raised on stilts, representative
of the stilt homes, called tuviq in Iñupiaq, of the Iñupiaq living on King Island, located just off of the Seward Peninsula coast, by
Teller. Painted in bright colors to liven winter darkness, these colors represent the vibrant petals of summer wildfl owers. At the
nearby amphitheater (not pictured but noted on the interpretive sign), visitors can build a camp fi re, winter or summer, and tell stories
of their Pilgrim Hot Spring days, or gather to hear a talk from one of the cultural interpreters working at the resort. Composting
outhouses and a private pool are shared by the six cabins.
93
geothermal facility
designed to blend into the surroundings and to refl ect the elegance of geothermal engineering, the simple looking facility
houses a unique geothermal system designed specifi cally for Pilgrim Hot Springs. Bringing electricity to the mission complex and
private cabins as well as coordinating heat to those same buildings, an educational room also exists within so that educational tours
of the facility can be organized.
94
signatainniq fields - cultural demonstration space
winter
as visitors leave the mission complex and head south to explore the rest of the site, their fi rst stop will be Signatainniq
Fields (signatainniq meaning ‘sharing Iñupiaq’ in Iñupiaq). In this perspective, the cultural demonstration space exhibits both
winter and summer seasonal housing and the traditional sod-house of the Iñupiaq. Built anew each year (as is the case with the
igloos and summer conical tents, but not so much for the sod-house) visitors can opt to spend the night in one of these structures.
95
summer
this outdoor space is also meant to host Reindeer and Trade Fairs and can span both sides of the road in order to
accommodate large crowds. This space is important to the whole design because it provides the richest interpretation and largest
space for the Iñupiaq to share their culture not only with visitors but with their own community; this is where grandparents teach
their grandchildren what it means to be Iñupiaq.
96
here, every tub has a perfect view of the Kigluaik Mountains.Unaataq, meaing ‘hot spring’ in Iñupiaq, lofts four tubs that allow 2-4
people to soak and celebrate the springs in. They are connected by raised wooden boardwalks so that in spring and summer time, wildfl owers
will be preserved and one can feel as though they are fl oating among the fl owers. These raised tub confi gurations are fi tted with overhead
structures from which to drape mosquito nets from in order to help protect soakers from Alaska’s ‘no-see-ums’. In winter, soft beacon lights
show visitors the way to warmth and roof windows frame the colors of the northern lights overhead.
97
unaataq boardwalk
98
wildlife trails
in this perspective, guests are shown on tour of the wildlife viewing trails which are located to the south of the site. They are standing
a safe distance form the yearling moose spotted munching on willow. A pair of tundra swan fl y overhead and the juvenile gyrfalcon just a
month shy of departing from its parents is experiencing a fi nal lesson.
99
interpretation
and fi nally, in this perspective which is located at the natural pool by the old bathhouse, a close-up of what interpretation and way-
fi nding signs to be found throughout the property could look like. They are to ensure that education and knowledge of the site is shared and passed
on to the visitor. Remember, education is the key to balancing recreation and conservation at Pilgrim Hot Springs’ Arctic Eco Resort.
100
here is a closer look at a possible
interpretation sign explaining the history of
the Old Bath House located at the natural
pool and picnic area. The post is made
to look like whale bones but would most
likely be made from wood and painted. The
backboard made of wood where you can see
the wood texture can be found on site from
the abandoned buildings. The rest of the sign
would most likely be made of painted metal
and screwed in place. The base represents
the Kigluaik Mountains that have formed the
backdrop to Pilgrim Hot Springs since time
immemorial. Also represented on the sign
is the fi reweed, Epilobium angustifolium,
the beautiful magenta herb that grows with
gusto throughout Pilgrim Hot Springs. This
is because of the nature of the plant with its
deep roots which allows it to escape damage
and be one of the fi rst species to grow where
land has been disturbed. It is a survivor of
ravaged landscapes and extends its abilities
to people caught in survival situations
able to provide food, drink, tinder, twine,
and medicine. It is an appropriate icon for
Pilgrim Hot Springs. For like the fi reweed,
Pilgrim Hot Springs has deep roots, rooted
in history and Iñupiaq culture, and like
fi reweed, a great potential to rejuvenate
itself in a neglected landscape.
pilgrim hot springs: a master plan
Bringing together geothermal energy, history and Iñupiaq culture to
create a sustainable and economically viable eco-tourism destination
to the Seward Peninsula, Alaska.
102
conclusion
limitations of study
As mentioned in the story of the design process, Pilgrim Hot
Springs has many layers of potential that stem from the layers of its
history. It has been a very interesting project to work on because it
involved researching arctic ecology, Iñupiaq culture, geothermal energy,
and being a detective to uncover the site’s past. Because there are so
many historic structures still existing on the site, it would have been
useful to collaborate with an architecture student interested in historic
preservation.
Originally hoping to be a community-based design project
working with Unaataq, LLC, and working to incorporate the wishes
of the board members, the geographical difference between Arizona
and Alaska proved insurmountable even with the communication
conveniences we have today. Because this project is so heavily focused
on sustainability, and even though its design concept emphasizes
education, having the support of the community and their involvement
every step of the way, is really what makes a project sustainable.
future research
Bearing in mind the study limitations, future research should
involve community-based research. Following this Master’s Report, a
summer internship working with Alaska Center for Energy and Power,
may allow for this community-based research to actually occur. It has
been a fortuitous arrangement getting to work with ACEP and utilize
the research they’ve conducted out at Pilgrim Hot Springs over the past
two summers. Additionally, because this project hopes to heavily utilize
geothermal capabilities; further collaboration should occur between
the landscape architect and the geothermal system design engineers.
Designing a geothermal system is beyond the scope of a Landscape
Architecture student. Again, this summer, this type of research may
also occur.
10310101010101010101011010111333333333333
104
works cited: literature review
Barbour, and Billings, eds. (2000). North American Terrestrial Vegetation. Cambridge, UK: Cambridge University Press
Bland, Laurel L. (1972). Imruk Basin Study. Anchorage, AK: Human Environmental Resource Services, Inc.
Buckley, R. ed. (2004). Environmental Impacts of Ecotourism. Cambridge, MA: CABA Publishing
Butler, R., and Hinch, T. eds. (1996). Tourism and Indigenous People. United Kingdom: International Thomson Business Press
Chance, Norman A. (1990). The Iñupiaq and Arctic Alaska: An Ethnography of Development. Fort Worth, TX: Holt, Rinehart, & Winston, Inc.
Dickson, Mary H., and Fanelli, Mario (2004). What is Geothermal Energy? Istituto di Geoscienze e Georisorse, CNR , Pisa, Italy http://www.geothermal-energy.org/314,what_is_geothermal_
energy.html [October 2012]
Duffi eld, H., & Sass, J. (2003). Geothermal Energy—Clean Power from the Earth’s Heat. Reston, VA: U.S. Geological Survey
Ellanna, Linda J., and Sherrod, George K. (2004). From Hunters to Herders: The Transformation of Earth, Society, and Heaven Among the Iñupiaq of Beringa. Fairbanks, AK: University of
Alaska Press
Farsani, N.T., Coelho, C., Costa, C., & Neto de Carvalho, C. eds. (2012). Geoparks & Geotourism: New Approaches to Sustainability in the 21st Century. Boca Raton, FL: BrownWalker Press
Fennell, D.A. (2002). Environmental Programme Planning. New York, NY: CABI Publishing
Hopfi nger, Tony (2012). Three-part series: To live and dies in Wales, Alaska. Aug. 28, 2012, Alaska Dispatch. http://www.alaskadispatch.com/content/three-part-series-live-and-die-wales-alaska
[October 2012]
Honey, Martha. (2008). Ecotourism and Sustainable Development. Washington, D.C.: Island Press
Honey, Martha. (2008). Ecotourism and Sustainable Development: Who Owns Paradise? Washington: Island Press
Indigenous Architecture of the Americas. Citing Websites: https://sites.google.com/a/risd.edu/indigenous-architecture-2012/materials/whalebone [accessed April 1, 2013]
Irimoto, T., & Yamada, T. eds. (1994). Circumpolar Religion and Ecology. Japan: University of Tokyo Press
Jones, Suzi ed. (2003). Eskimo Drawings. Anchorage, AK: Anchorage Museum of History and Art
Krupnik, I., Mason, R., & Horton, T., eds. (2004). Northern Ethnographic Landscapes: Perspectives from Circumpolar Nations. Anchorage, AK: University of Alaska Press
Lal, R., Kimble, J.M., and Stewart, B.A. eds. (2000). Global Climate Change and Cold Region Ecosystems. New York, NY: Lewis Publishers
Lund, John W. (2009). Development and Utilization of Geothermal Resources. Klamath Falls, OR: Geo-Heat Center http://www.springerlink.com/content/hjxuk75267445v80/ [October 2012]
National Park Service. (2012) Bering Land Bridge National Preserve. http://www.nps.gov/bela/index.htm [October 2012]
National Register of Historic Places (1977). Pilgrim Hot Springs Kruzgamepa, Teller, Seward Peninsula, Alaska, National Register #BEN-014
105
Nature Snippets: Fruticose Lichens. Citing Wesite: http://naturesnippets.com/tag/raindeer-moss/ [accessed April 24, 2013]
Oquilluk, William A. and Bland, Laurel L. (1973). People of Kauwerak: Legends of the Northern Eskimo. Alaska Pacifi c University Press
Rasmussen, R.O., & Koroleva, N.E. eds. (2003). Social and Environmental Impacts in the North. Netherlands: Kluwer Academic Publishers
Reinhardt, Gregory (2010). Eskimo Architecture: Dwelling and Structure in the Early Historic Period. Anchorage, AK: University of Alaska Press
Schaaf, Jeanne. (1996). Ublasaun: First Light, Iñupiaq Hunters and Herders in the Early Twentieth Century, Northern Seward Peninsula, Alaska. Alaska Field Area; National Park Service.
Schofi eld, Janice J. (1989). Discovering Wild Plants; Alaska, Western Canada, the Northwest. New Zealand and Alaska: EATON
Leckie, Seabrooke: Today not a Kingsbird- British Soldiers. Citing Website: http://seabrookeleckie.com/tag/cladonia-cristatella/ [accessed April 24, 2013]
Smith, Macleod, and Robertson. (2010). Key Concepts in Tourism Studies. Las Angeles, CA: Sage Publications
Sorensen, Bent ed. (2009). Renewable Energy Focus Handbook. Boston: Academic Press
Sznajder, M., Przezborska, L., & Scrimgeour, F. (2009). Agrotourism. Cambridge, MA: CABI Publishing
Tieszen, Larry L. eds. (1978). Vegetation and Production Ecology of an Alaskan Arctic Tundra. New York, NY: Springer-Verlag New York Inc.
Tyler, Norman, Ligibel, & Tyler (2009). Historic Preservation: An Introduction to Its History, Principles, and Practice. New York, NY: W.W. Norton & Company, Inc.
University of Alaska, Fairbanks. (2012). Validation of Innovative Exploration Techniques, Pilgrim Hot Springs, Alaska: Phase 1 Final Report. Fairbanks, AK: Department of Energy, Alaska
Energy Authority, and the University of Alaska, Fairbanks.
Wright, H.E, Jr., & Osburn, W. H. eds.(1967). Arctic and Alpine Environments. Bloomington, IN: Indiana University Press
106
Blue Lagoon:
Blue Lagoon. Citing Websites: http://www.bluelagoon.com [accessed October 16, 2012]
Chena Hot Springs:
Chena Hot Springs. Citing Websites: http://www.chenahotsprings.com/ [accessed August 10, 2012]
Cree Village Ecolodge:
Cree Village Eco Lodge (2006). Citing Websites. http://www.creevillage.com/ [accessed October 16,2012]
Howard, Brian Clark. (2012). 17 of the Best Eco Lodges in the World. Citing Websites: http://www.thedailygreen.com/living-green/best-eco-lodges [accessed October 15,
2012]
Hotel Kakslauttanen:
Hotel Kakslauttanen (2012). Citing Websites. http://www.kakslauttanen.fi /en/ [accessed October 15, 2012]
Onebestway. Activities Abroad: Hotel Kaksaluttanen. Citing Websites:
http://www.activitiesabroad.com/holidays/276/design-your-own-holiday [accessed October 15, 2012]
Quantum Glass. Heating Glass Solutions for Cold and/or Wet Environments. Citing Websites: http://www.quantumglass.com/heat-skin-heating-glass-solutions/concept
[accessed October 15, 2012]
Liard Hot Springs:
British Columbia Parks. Liard River Hot Springs Provincial Park. Citing Websites: http://www.env.gov.bc.ca/bcparks/explore/parkpgs/liard_rv_hs/index.html [accessed
October 18, 2012]
Sage Internet Solutions. (1998). Liard River Hotsprings, Northern BC. Citing Websites: http://www.britishcolumbia.com/hotsprings/?id=18 [accessed October 18, 2012]
Manley Hot Springs:
DART-AM Farms (2010-2011). Remembering the Past, Looking to the Future. Citing Websites: http://www.manleyhotspringsproduce.com/ [accessed October 19, 2012]
Manley Hot Springs. Citing Websites: http://fairbanks-alaska.com/manley-hot-springs.htm [accessed October 18, 2012]
Stepping Stone Heritage Farm:
Stepping Stone Heritage Farm. Citing Websites: http://www.steppingstoneheritagefarm.ca/ [accessed December 10, 2012]
Tolovana Hot Springs:
Aida de L’Isle (2007). Tolovana Hot Springs. Citing Websites: http://www.tolovanahotsprings.com/ [accessed October 18, 2012]
World Wide opportunities on Organic Farms:
WWOOF (1998-2013). Citing Websites: http://www.wwoof.org/ [accessed December 10, 2012]
WWOOF USA. Citing Websites: http://www.wwoofusa.org/ [accessed February 15, 2013]
works cited: case reviewsrc c r
107
image sourcesimage sources
All photographs and drawings by Desneige Hallbert unless otherwise noted.
All aerials: Alaska Center for Energy and Power
All USGS map data: National Park Service
Page 14: Art entitled: The Wolf Dance by James Kivetoruk Moses. Found in the book: Jones, Suzi ed.
(2003). Eskimo Drawings. Anchorage, AK: Anchorage Museum of History and Art: pg. 114
Page 16: Story Bracelet: http://www.etsy.com/listing/64764579/reserved-for-aliesyn-vintage-rare-harry
Page 17: Inupiaq women elders dancing: http://www.nps.gov/akso/beringia/about/spotlight/lost-dances.
cfm
Page 19: Art entitled: Blanket Toss by George Aden Ahgupuk. Found in the book: Jones, Suzi ed.
(2003). Eskimo Drawings. Anchorage, AK: Anchorage Museum of History and Art: pg. 86
Page 20 top: Interior of Inupiaq winter hut found in the book: Reinhardt, Gregory (2010). Eskimo
Architecture: Dwelling and Structure in the Early Historic Period. Anchorage, AK: University of Alaska
Press: pg. 85
Page 20 bottom: Whale bone door to an Inupiaq sod house: http://inupiaqeskimo.wordpress.
com/2012/10/
Page 21: Ivory mermaid carving: http://www.homeandaway.biz/product-multi.cfm?Product_
ID=ALI00289
Story bracelet: http://www.maruskiyas.com/store/products/story-bracelets-albert-olanna
Page 24: Image of a schematic representation of an ideal geothermal system:
http://www.geothermal-energy.org/geothermal_energy/what_is_geothermal_energy.html
Page 25: Chena Hot Springs greenhouse interior: http://www.chenahotsprings.com/photo-gallery/chena-
fresh/
Page 26 right: Sketch of an atmospheric exhaust geothermal power-plant: http://www.geothermal-
energy.org/geothermal_energy/what_is_geothermal_energy.html
Page 26 left: Chena Hot Spring Resort’s Geothermal Energy System: http://www.chenahotsprings.com/
photo-gallery/renewables/
Page 27: Alaska Center for Energy and Power FLIR image
Page 28: Sustainable tourism concept image http://www.tourism-master.nl/2011/11/25/code-of-conduct-
in-tourism-and-their-impact-on-sustainable-tourism/
Page 31: WWOOFing Canada website page: http://www.wwoof.ca/
Page 32: Serpentine Hot Springs granite tors image: http://www.nps.gov/nr/travel/cultural_diversity/
America_The_Nation_of_Nations.html, http://www.fotopedia.com/items/fl ickr-3767403588
Page 33: Brook
Page 39: Chena Hot Springs image: http://www.terragalleria.com/blog/2012/06/21/chena-hot-springs-
alaska-2/
Page 40: Chena Hot Springs’ Resort birds eye: http://www.visualitineraries.com/VisitPoint.asp?location
=2002&title=Chena+Hot+Springs+Resort
Page 42: Geothermal Energy production system: http://www.chenahotsprings.com/photo-gallery/
renewables/
Page 43 left: Natural Pool http://www.city-data.com/picfi lesc/picc46828.php
Page 43 right: Northern lights: http://www.panoramio.com/photo/1479616
Page 44 left: Dog Kennels: http://www.travbuddy.com/photos/blogs/2203087
Page 44 right: Hot tubs in Greenhouse: http://blog.unurban.no/#post12, http://www.geocaching.com/
seek/cache_details.aspx?guid=9f249ba5-2682-4e6b-a9e4-0cae82dd8068
Page 45 left: Manley Roadhouse: http://www.oddinns.com/index.php/pages/ManleyRoadhouse.html
Page 45 middle: Path: http://www.bumfuzzle.com/2008/07/
Page 45 right: Sod house: http://www.travbuddy.com/photos/blogs/2203085
Page 46 left: Tolovana wood tub: http://www.tolovanahotsprings.com/photos/pages/15.html
Page 46 right: Tolovana tub: http://www.fl ickr.com/photos/michaelshawkins/7088333355/
Page 47 right: Tolovana ski in: http://edplumb.blogspot.com/2008/01/new-year-begins-at-tolovana-hot-springs.
html
Page 47 middle: Tolovana wooden tub in winter: http://www.fl ickr.com/photos/nvmountainchild/3435986686/
Page 47 left: Northern lights at Tolovana: http://www.tolovanahotsprings.com/photos/pages/6.html
Page 48 left: Liard in the fall: http://www.tripadvisor.com/Attraction_Review-g154922-d622961-Reviews-Liard_
Hot_Springs-British_Columbia.html
Page 48 right: Liard in springtime: http://suethomas.ca/LiardHotSprings.html
Page 49 background: http://suethomas.ca/LiardHotSprings.html
Page 49 right: Liard boardwalk: http://travelswithmiranda.uskeba.ca/?p=1445
Page 49 middle: Liard in winter: http://www3.sympatico.ca/fstephenson/nomad.htm
Page 49 left: Liard waterfall: http://www.youryukon.com/gallery/v/britishcolumbia/liardhotsprings/
Liard+Hot+Springs+09.jpg.html
Page 50 left: Svartsengi Power Plant http://ypratomo.tumblr.com/post/7397580937/green-energy-for-the-blue-
planet#_=_
Page 50 right: Blue Lagoon bridge and resort: http://www.tourist-destinations.com/2013/02/blue-lagoon-iceland-
travel-guide.html
Page 51 background: http://www.icelandunlimited.is/tours/romantic-getaway-in-iceland-for-7-days/attachment/
blue-lagoon-4/
Page 51 right: Blue lagoon bridge: http://www.okeanosgroup.com/blog/uncategorized/freeze-then-simmer-at-the-
blue-lagoon-resort/
Page 51 middle: Blue Lagoon soaking: http://openplac.es/trips/blue-lagoon-in-iceland
Page 51 left: Blue Lagoon fl oating boardwalk: http://www.sushi-suzuki.com/sushilog/2013/01/cute-little-iceland/
Page 52 left: Close up of glass igloo: http://www.cozi.com/live-simply/10-extreme-hotels-extraordinary-family-
vacation
Page 52 right: Rows of glass igloos: http://www.kakslauttanen.fi /en/resort/igloo-village
Page 53 left: Kota Restaurant interior: http://www.kakslauttanen.fi /en/activities/lapland-treats
Page 53 middle: A member of the Sami people in traditional dress: http://www.kakslauttanen.fi /en/activities/
lapland-treats
Page 53 right: Siida Museum tool exhibit: http://www.kakslauttanen.fi /en/services/
Page 54 left: Cree Village Ecolodge: http://bydianedaniel.wordpress.com/2010/12/18/a-gift-idea-for-the-
armchair-eco-traveler/
Page 54 middle: Close up of the Ecolodge: http://www.thedailygreen.com/living-green/cree-village-ecolodge
Page 54 right: Northern lights over the Cree Village Ecolodge: http://www.fl ickr.com/photos/
robertseandavies/6024758516/
Page 55 left: Simple Welcome sign: http://www.creeadventures.com/photo%20album.htm
Page 55 middle: Boat beach: www.panoramio.com/user/1774844/tags/moose%20factory
Page 55 right: Interior of the Ecolodge: http://www.aboriginal-ecotourism.org/spip.php?article571
Page 55bottom: Aerial of the Moose Factory Island: http://www.creeadventures.com/MF%20winter%20Picture.
htm
Page 56 top: Stepping Stone Sign: http://www.steppingstoneheritagefarm.ca/
Page 56 middle: Stepping Stone gardens: http://www.steppingstoneheritagefarm.ca/
Page 56 bottom: Sheep: http://angelcatuk.blogspot.com/2011/03/sheep.html
Page 57: WWOOF USA website: http://www.wwoofusa.org/
Page 64: Entry gate: Brook
Page 64: Winter camping: http://www.alaskatent.com/oven/aogallery.html
Page 64: Spring Kigluaiks: http://www.alaska-in-pictures.com/kigluaik-mountains-3053-pictures.htm
Page 68: Plan drawing: National Register of Historic Places Inventory—Nomination Form: April 11th 1977
Page 70: Temperature images: Alaska Center for Energy and Power
Page 71 top: Close-up of fl ooded Mission Complex: Alaska Center for Energy and Power
Page 71 bottom: Flooded Imuruk Basin image: Alaska Center for Energy and Power