Loading...
HomeMy WebLinkAboutDCVR-LCMF-15DESIGN CLARIFICATION/VERIFICATION REQUEST CONTRACTOR: Hankal Construction, Inc. PROJECT: Unalakleet Bulk Fuel Upgrade SPEC. NO.: DC/VR NO.: LCMF-15 CONTRACT NO.: REG-06-088 DRAWING NO.: C-12 UVEC Dike Rev DESCRIPTION OF REQUEST: Upsize the containment dike at UVEC Power Plant per attached C-12 Dike Rev drawing and sketch detail. Cost breakdown for the change as per attached Hankal Construction, Inc. Change Request #4. ATTACHMENT: YES® NO[] CHANGE ORDER: YES® NO❑ IF YES PROVIDE RFP: See attached WRITTEN BY: Egor Esi o --;-- APPROVED BY : Daniels RESPONSE: RFP REQUIRED: YES BY: NO Hankal Construction, Inc. Hankal Construction Change Request #4. DATE: DATE: 06-01-07 DATE: 06-01-07 This is NOT an authorization for additional reimbursement or time extension. Authorization of such can be made only by the owner through a change order in accordance with the contract documents. DCVRFORM NOTES HRR - - HRR 4S HRS - �r FO UNALAKLEET TOWNSI TE PLAT 87-11 -\LUUL OF ROAD \ BEACH ROAD EAST -J------_—_—___—_—CENTERLINE OF RIGHT_OF-WqY \ 1. LOCATIONS OF UNDERGROUND UTILITIES ARE BASED ON LIMITED AS -BUILT DRAWINGS. FIELD VERIFY ALL LOCATIONS BEFORE CONSTRUCTION. INSTALL NEW TANK ON NEW CONCRETE RING WALL. INSTALL NEW DIKE LINER UNDER TANK AND CONCRETE RING WALLS. EXTEND PRIMARY LINER TO TOP OF RECONSTRUCTED DIKE WALL. - _ FOR LARGE SCALE PIPING PLAN SEE Q(SIMILAR) HRR & HRS HRR & HRS --- "-- TO SCHOOL TO BALER NEW 4"0 UVEC PIPELINE FROM BULK HRR BUILDING FUEL TANK FARM, ADJUST EXACT W - - - - - - HRR �_�_HRR HRR LOCATION OF PIPELINE AS NECESSARY z EDGE OF ROAD - Ham- - - N 73_53'S4" E HRR TO AVOID EXISTING BELOW GRADE UTILITIES -HRS HRS HRS 147.18 - - - - - - - - HRR HRR - HRR V \ ` HRS HRS HRS o HRS HRS - C HRS {BOTH/E OH/E-„3� OH/E - - \� y / \ _ _ _ - _ - - _ \ =SOH/E _ - _ OH - - - - - - - - - - - -� 4+00!' OH - FO IrIG / � I i i 0 I NIA WATER MAIN UNALAKLEET TO WNSI TE PLAT 87-11 3 FROM WATER PLANT I I I V1 � i INI 7U 1 �i T T __--SEMENT - - - - �/ -OH/E FO FO FO FO _ - - - _ T I ! I \ CATHODIC / FO I - PROTECTION - \ I \ \ \ I FO FO ��'r'3FE'h1�4fp0� 1 \ FO \ \ \ \ w w \ I \ AT 700' ff C. \ UNALAKLEET 1 \ \ \ I I1 \\I 10' BELNSITIOOTO WNSI TE FROM PLAT 87-11 \ POWER PLANT TO ABO IIND FINISH FLOOR ELEVATION = 13.3' I \ PROVIDE PIPE S PPORTS A \ I I I I II I I I 12• \ 1 MAXIMUM OF 10. ON CENTER, e \ I I I I I I I \ I SUPPORT FROM UILDING AND 14 \ I I I I I! 1 I I I/ FROM GROUND TIMBERS CONNECT NEW 2"0 SCHEDULE 80 PIPING TO EXISTING 2"0 PIPING INSIDE POWER PLANT CONNECT EXISTING 314"0 COPPER HRS// UNALAKLEET AND HRR JACKET WATER TO NEW INSULATED \ I I I I / / / Iy TOWNSITE E AND HEAT TRACED FUEL SUPPLY PIPING. 3+00 1 I I I I / / / /I PLAT 87-11 EXISTING INSULATE AND HEAT TRACE 2"0 1 DOOR P.P. 11 • I I I / / I POWER PLANT FUEL SUPPLY PIPING M_5 FIRE 1 10,I 5 EXTINGUISHER 11 I I I 15' / 1 I I I I l\\\ PIPE SUPPORT 2 1 I I I I \\\\ GCI (TYPICAL) _14 CONTROL I 1 I I I I \\\\ PANEL I I I I I \\\\ I 14.0 PROVIDE 12"X8" Z TIMBERS PRESSURE T REA E ATEACH END ATT ND / Nh 1 I I I I \\ \\ \\\ �\ I 3 \14 - AND AT ALL SUPPORT POINTS NIN / I I I I \\ \\ \ \ /U I , PREMANUFACTURED o _ DIKE ACCESS STAIRS C49 53. 0' TANK #PP1 63.0' (51.0' MINIMUM) (51. 0' MINIMUM) 0 89,000 GALLON 7.Ot DIESEL No. 2 N CENTERLINE OF TEE 3 / _ (25'-2"0 x 24'-0" HIGH) I �4.� 3.0 ICHAIN LINK FENCE MAN GATE \\ \\ \ \ SUMP C_519 //\ 4'018SCHEDULE L80 ABOVE O) GROUND PIPING(TY _CAL F 2(SIMILAR) RELOCATED UVEC SPILL 2_ 72. 0NSE CONTINGENCY C19 3 137 CORNER POST FUEL TANKNSTALLRSTOPROE TAN, ION THREE 6x6x1S0PRESS RE TREATEDTIMBER liI IIIII1 \ \ \I \ \\ 11 3 (TYP.) 13.4 8.0' SATELLITE DISH - - - - - - - - - - - - C-219 (TYP.) (36'0 x 24"-0' HIGH) I I 1 \ \ \ LINE POST _ - - \ (TYP) CONSTRUCT NEW 72' X 40' 74- _ = i I II - _ \ STEEL CONTAINMENT DIKE WALL I 1 \ 1 I! ^ 1 I I II AND FENCE TO MATCH EXISTING \ \ 14 FUEL TANK I I \\ SHED h C, 9 88,600 GALLON FUEL TANK I \ / 88,600 GALLON (25.25'OX23'-8" HIGH) 15 I I \ - I- - - - (25.25'0 X 23'-8" HIGH) I / / SHED I _ it I PROPERTY CORNER ,/L ��/,0 10' 20' N 249819.69 14"E 352181.35 / �.----12' _ if"/ / _-_-' i'i' - - - 1 - - S 7233'18"W - - - - -- - _ - - --- 10i-J=--===i -SCALE IN FEET- 1 1 - - - - - - UVEC POWER PLANT TANS SITE PLAN C-12 SCALE: 1" = 10' UNALAKLEET TO WNSI TE PLAT 87-11 TO FIRE SPRINKLER RISER WAS T HEAT UTILIDOR EXISTING - DOOR P.P. 5.0' 6 BOLLARD C-18 (TYPICAL OF 3) EXISTING REMOTE RADIATOR 2 0 cc W W Q U) J Q Y 1 Z O` r � 2g U UH a; DZcc o w N� NFU Z(� os& 0a DRAWN BY: EE CHECKED BY: JD DATE: 05/31/07 JOB NUMBER: 05-756 SCALE: AS SHOWN DRAWING TITLE: UVEC DIKE REVISION SHEET: OF C-12 Ha kaa CGms�rudion, Inc. 550 W. 54t1i Avenue Anchorage, Alaska 99518 (907)563-5719 General FAX: (907) 562-6496 Industrial May 22, 2007 Fax: 273-1830 REG-06-088 LCMF, hie. 615 E. 82nd Ave. Ste 200 Anchorage, AK 99518 REFERENCE: UNALAKLEET BULK FUEL UPGRADE ATTENTION: JOE DANIELS SUBJECT: CHANGE REQUEST 4 — UPSIZE CONTAINMENT DIKE AT UVEC POWER PLANT Gentlemen The following is a cost breakdown for Change Request No. 4 I. LABOR Superintendent 12 ME @ $107 $ 1,284.00 Operator 16 MH @ $94 $ 1,504.00 Welder 3 MH @ $91 $ 312.00 Laborer 65 MH @ $82 $ 5,330.00 Laborer (fence) 40 MH @ $82 $ 3,280.00 Expediter 5 MH @ $45 $ 225.00 Subtotal 1: $ 11,935.00 I.I. EQUIPMENT Excavator '/x day @ $900 $ 450.00 L-70 Loader 1 %a day @ $500 $ 750.00 Compactor 1 day @ $225 $ 225.00 Welding Truck '/a day @ $300 $ 150.00 Flat Bed '/2 day @ $150 $ 75.00 Crew Transport Pickup 1 week @ $400 $ 400.00 Subtotal II: $ 2,050.00 III. MATERIALS Cooley L1023 2000 sf @ 1.95 $ 3,900.00 Non -woven Geotextile 500 SY @ 0.914 $ 457.00 Freight for above 630 lbs @ $1.00 $ 630.00 Bedding Sand 24 cy @ $43.50 $ 1,044.00 Select Fill 50 cy @ $42.00 $ 2,100.00 Fuels 50 gal @ $5.00 $ 250.00 Subtotal III: $ 8,381.00 Z IV. OUTSIDE SERVICE Seaming Technician 2 days @ $750 RT Airfare 1 @ $420 Other Expenses 2 days @ $150 Subtotal Item IV: Total Items I,11,111 and IV: Overhead & Profit @ 17%: Subtotal: Bond @ 1.5%: Subtotal: Insurance @ 2%: Total: GRAND TOTAL: We request a one (1) week extension of contract time for completion of this work. $ 1,500.00 $ 420.00 $ 300.00 $ 2,220.00 $ 24,586.00 $ 4,180.00 $ 28,766.00 $ 431.00 $ 29,197.00 $ 584.00 $ 29,781.00 $ 29,781..00 If you have any questions or require additional information, please contact the undersigned at your earliest convenience. Sincerely, Dave Shellenberger Project Manager 2 05I1812007 09:18 907-562-7003 POLAR SUPPLY CD PAGE 01/02 r Polar Supply Co. a dlvlslon of E-Malk sgordner@polarsupply.corn Spenard Builders Supply Web Slle: www.polarsupply.com 300 E. 54th Ave, Dale: 5/16/2007 Anchorage,AK 99510 To: Henkel Gonsl Main Phone: (907) 563.5000 Attn. Dave Shellenbur9or Main Fax; (907) 581.1050 Rona: 563.5719 Alternate Fax: (907) 562.700 Fax: 562-8496 "Quality Products for Quality Projects" U nalaklee# Change Order MATERIAL ESTIMATE We are Pleased to Quote the followlnsl matsrials for the referenced Project: Bid Item Material Desetiptlon Approx. QuantityUnit Unit Lbs. Per Unit Price Extended Price F.0,13, Point Apprux. Availability- Availability— Goolev L1023 Black Urethane Membrane 58' x 34.5' Goole 2000 5F 0.19 $1.950 $3 900.60 Polar Yard 2.3 weeks P rop ax BO1 Mon -Woven Gealextile 15' x 300' rolls 0 SY 0.50 $0.914 Polar Yard 5locked Item Please Note., -z-r549 �6$ coo Ie �630 16; The altached "Standard Terms and Condiiigns" are a pars of Ns quotation Steve Gardner Geotechnlcal I Environmental Division Polar Supply Co. I! you have any technical queslions please call Steve Gardner a1 907.646.4715 The Geolechnical 1 Environmental Division fax number is 907.562.7003 Accepted Page t at 2 E H q e ii NKUS_ son NINE .ee .Ei .0 .i_HE0I _i__ . c� __—__i _M_-IN mmm OMEN almo9eIMM11mmm._ Maa� e__"' _I eii0 _■�._ .iim ilm- _mom[ ii_�iiim_— �e___ _...- _C. OMISIMM'�E SINS 6E 6mill�-E .a.a..a� O man aCC:INIS eam: ::I: _:: C®� ON •_�� a::��61a�� Elm smi_:E� E � iia a 6_lima sm H 6 6_ E_ _ ._.n.a CC�:a�:CC�lM MI =ca- MUSE Imamloan: Im Ilm_ a iii CloigZ.a _=.i--i9s: i ! I : 0 1lima� 6:m E d n �- Mid E� IN=- a IN mill 8 MEET. y a1 1 I I 1 1 11 'Io � 11 olll _ ®1111 l�Ilillllllll111111111 1 IIIIIIIII 11�1 11 III p O I W E �❑ V �5LL x x �o S � �] N �Q a �r c L n t�