HomeMy WebLinkAbout05-756 C-00 Cover SheetBarrow
RECORD DRAWING
THESE DRAWINGS HAVE BEEN PREPARED AL)kSICk ENERGY AU I H01RJ I Y
FROM MARKED -UP DRAWINGS SUPPLIED BY
THE CONTRACTOR. AN AS -BUILT SURVEY
HAS NOT BEEN CONDUCTED. FIELD VERIFY
ANY INFORMATION CONTAINED HEREON
BEFORE USING.
aao
x
�c
0
z
0 0.5 1.0
APPROXIMATE SCALE IN MILES
UNALAK
UNC BARGE \\\\\
LANDING
MATERIAL \�
SOURCE
(BEA CH) \
BEACH
ROAD -
ROAD
CLOSED
(SOUTH BOUND)
NORTON
SOUND
CONSULTANTS
k
r�
LEE'
�� VICINITY MAP
UNALAKLEETlim-E
1'--,
r�
I � i
WHITE ALICE
ROAD
LANDFILL
LANDFILL ROAD
/\ —PROJECT
LOCATION
CITY
DOCK \ \
LOCATION MAP
RSA Engineering, Inc.
MECHANICAL AND ELECTRICAL CONSULTING ENGINEERS
2522 ARCTIC BLVD. SUITE 200 • ANCHORAGE, AK 99503-2516 (907)276-0521
BULK FUEL UPGRADE
UNALAKLEET, ALASKA
RECORD DRAWINGS
NOVEMBER 15, 2007
INDEX TO DRAWINGS
chikan COVER SHEET
GENERAL
MECHANICAL
G-1
COMMUNITY FUEL DATA
M-1
SCHEDULES AND LEGEND
AND FUEL SYSTEM DIAGRAM
M-2
FUEL SYSTEM PIPING SCHEMATIC
G-2
SURVEY CONTROL
M-3
TANK FARM PIPING PLAN
CIVIL
M-4
46,600 GALLON VERTICAL BULK TANK
C-1
PROJECT LAYOUT PLAN
M-5
89,000 GALLON VERTICAL BULK TANKS (TANK #PP1, #3, #18 AND #22)
C-2
GENERAL NOTES, ABBREVIATIONS, AND LEGENDS
M-6
4,000 GALLON DOUBLE WALL INTERMEDIATE TANK (TANK #SC1)
C-3
TANK FARM SITE PLAN
M-7
500 GALLON DOUBLE WALL SUPPLY TANKS
C-4
TANK FARM GRADING PLAN
M-8
1,000 GALLON DOUBLE WALL SUPPLY TANK
C-5
TANK FARM LAYOUT PLAN
M-9
5,000 GALLON PROTECTED DISPENSING TANK (TANK #CP1)
C-6
VERTICAL TANK FOUNDATION DETAILS
M-10
3,000 GALLON DOUBLE WALL INTERMEDIATE TANK (TANK #CY1)
C-7
TANK FARM THERMOSYPHON PLAN
M-11
3,000 GALLON PROTECTED DUAL PRODUCT DISPENSING TANK (TANK #CY2)
C-8
TANK FARM DIKING PLAN
M-12
PUMP ENCLOSURE DETAILS
C-9
TANK FARM SECTIONS
M-13
PIPING DETAILS
C-10
TIMBER CONTAINMENT DIKE DETAILS
M-14
MECHANICAL DETAILS
C-11
U VEC POWER PLANT TANK FARM REMOVAL PLAN
M-15
MECHANICAL DETAILS
C-12
U VEC POWER PLANT TANK SITE PLAN
C-13 CITY WATER PLANT SITE PLAN ELECTRICAL
C-14 BSSD SCHOOL SUBDIVISION PLAN E-1 ELECTRICAL LEGEND, FIXTURE SCHEDULE, SITE PLAN
C-15 BSSD LARGE SCALE SITE PLANS E-2 ONE —LINE DIAGRAMS AND DETAILS
C-16 BSSD STORAGE BUILDING AND E-3 TANK FARM HAZARDOUS AREA AND GROUNDING PLANS AND DETAILS
HOUSING SITE PLAN E-4 ELECTRICAL PLAN, BULK TANK FARM
C-17 UNC GAS STATION SITE PLAN E-5 TANK FARM ENLARGED ELECTRICAL PLANS
C-18 CIVIL DETAILS E-6 POWER PLANT ENLARGED ELECTRICAL PLANS
C-19 CIVIL DETAILS E-7 CITY DISPENSER AND UNC GAS STATION ENLARGED PLANS AND DETAILS
C-20 KOUWEGOK SLOUGH BRIDGE PLAN E-8 CONTROL PANEL 'CP-1' SCHEMATIC DIAGRAMS AND DETAILS
C-21 KOUWEGOK SLOUGH BRIDGE DETAILS E-9 CONTROL PANEL 'CP-2' SCHEMATIC DIAGRAMS AND DETAILS
C-22 PIPELINE PLAN 1 E-10 TRUCK FILL CONTROL PANEL SCHEMATIC DIAGRAMS AND DETAILS
C-23 PIPELINE PLAN 2 E-11 COMMON CONTROL PANEL 'CP-6' SCHEMATIC DIAGRAMS AND DETAILS
E-12 CITY DISPENSING CONTROL PANEL 'CP-7' SCHEMATIC DIAGRAMS AND DETAILS
E-13 ELECTRICAL DETAILS
cn
Q z
oEr-
0 3:
Q
� J Y p
Q W Q p
Off`~O
� w O O
W J J W
z YQ� LC)
LLj ma Ln
aw�0
(n J z r
Q��~ O
w
J � z
Q Z z Q
v O w p U
Z -D Q D wLd
w_ O O U D O
Er- O O C/) Q�
Ca- JpV)a_