Loading...
HomeMy WebLinkAbout05-756 C-10Ln Ld • 6 6 VARIES VARIES SCALE: NONE FASTEN 2x6, METAL COVERS AND MEMBRANE LINER WITH (2) 3/8"Ox3" GALVANIZED LAG SCREWS AT 18" ON CEN TER ---\ ATTACHED GALVANIZED PIPE STRAP TO 6x6 FENCE POSTS (2) 3/8" OX 4" LAG SCREWS - 8x 12 PRESSURE TREATED TIMBER POST 0 EMBED FENCE POSTS 18" BELOW GRADE GRAVEL FILL TYPICAL JOINT CONDITION 5x6 PRESSURE TREATED TIMBER SHEET METAL DIKE LINER COVER 3 �ORNER PIECE (TYPICAL) C-10 3x 12 PRESSURE TREA TED TIMBER POST 3/4"Ox8" GALVANIZED LAG SCREWS WITH WASHERS DRE-DRILLED AND OUNTERSUNK SHEET METAL DIKE WALL FACING 6 AND DIKE LINER COVER C-10 (TYPICAL) 10.0 HIGH FENCE POST WITH 5.0' CHAIN LINK FENCE FABRIC AND BARBED WIRE 6x6 PRESSURE TREA TED TIMBER 3/4" Ox8" GALVANIZED LAG SCREWS WITH WASHERS PRE -DRILLED AND COUNTERSUNK 16 GAUGE GALVANIZED SHEET METAL DIKE LINER COVER (SEE NOTE 3) 16 GAUGE GALVANIZED SHEET METAL DIKE WALL FACING (SEE NOTES 2 AND 3) 3" BEDDING SELECT EACH SIDE `FILL OF LINER FINISH GRADE � Z GRA VEL RIGID FILL I INSULA TION SCALE: NONE z N NON -WOVEN GEOTEXTILE PRIMARY MEMBRANE LINER NON -WOVEN GEOTEXTILE PROVIDE "EXCESS LINER AND GEOTEXTILE UNDER SHEET METAL CHAMFER. " 6 6 tin Qlr-c 11A Ph7c ? PRESSURE ATED TIMBER POST PRESSURE TREA TED 'ER (TYPICAL EACH SIDE) ET METAL DIKE LINER ER CORNER PIECE 'ICAL EACH SIDE) ? PRESSURE ATED TIMBER POST 3/4"Ox8" GALVANIZED LAG SCREWS WITH WASHERS PRE -DRILLED AND COUN TERSUNK (TYPICAL EACH SIDE) I I I I I I I I ° ° 1/4 I I I I ° O I I I I I I I FENCE POST ATTACHMENT: 3/8 "X8 "X 1 '- 4 " STEEL PLATE 8 i WITH FOUR 3/4 " OX6 "LAG SCREWS. WELD FENCE POST TO PLATE AND COAT WITH 12 ; COLD GALVANIZING COMPOUND I I I I I I I I I I I I INTERIOM DOE DETAIL SCALE: NONE 5.0' HIGH FENCE POST WITH 5.0' CHAIN LINK FENCE FABRIC (NO BARB WIRE ON 1 /4 INTERMEDIATE DIKE) 3/8"X8"X1'-4" STEEL PLATE FASTEN 2x6, METAL COVERS AND MEMBRANE LINER WITH (2) 3/8" Ox3" 2x8 PRESSURE GALVANIZED LAG SCREWS AT 18" ON TREATED CENTER (TYPICAL EACH SIDE) 6x6 PRESSURE TREA TED TIMBER (TYPICAL EACH SIDE) 3/4"Ox8" GALVANIZED LAG SCREWS WITH WASHERS PRE -DRILLED AND COUNTERSUNK (TYPICAL EACH SIDE) 16 GAUGE GALVANIZED SHEET METAL DIKE LINER COVER (TYPICAL EACH SIDE, SEE NOTE 3) 77 16 GAUGE GALVANIZED SHEET METAL DIKE WALL FACING ZZ (TYPICAL EACH SIDE, SEE NOTES 2 & 374 3" BEDDING SELECT EACH SIDE FILL FINISH GRADE OF LINER NON -WOVEN GEOTEXTILE GRAVEL PRIMARY MEMBRANE LINER NON -WOVEN GEOTEXTILE FILL 8x12 PRESSURE RIGID TREATED TIMBER POST INSULATION SCALE: NONE �D L0 L0 SCALE: NONE SCALE: NONE L L.J 1 LAYOUT 3„ 4, NOTES 1. NO PENETRATIONS ALLOWED THROUGH MEMBRANE LINER EXCEPT AT TOP OF DIKE. 2. ATTACH TIMBER DIKE WALL SHEET METAL FACING TO DIKE WALL WITH COUNTER SUNK SCREWS SUCH THAT HEADS OF SCREWS ARE FLUSH WITH SHEET METAL. SEAL SCREWS AND JOINTS WITH FUEL RESISTANT SEALANT. 3. OVERLAP VERTICAL DIKE WALL FACING AND DIKE LINER COVER SHEET METAL JOINTS 2" (MINIMUM) AND SEAL WITH FUEL RESISTANT SEALANT. ALLOW 3" MINIMUM OF EXCESS LINER AND GEOTEXTILE AT BASE OF DIKES FOR SETTLEMENT AND EXPANSION. 5. COORDINATE POST PLACEMENT TO AVOID THERMOSYPHON LOOPS. SEE SHEET C - 8 FOR LAYOUT OF 8x 12 PRESSURE TREATED TIMBER POSTS, SPACING VARIES. 3" 4»+ SECTION 1/2" HEM 16 GAUGE GAL VANIZED SHEET METAL 1/2" HEM TOP SIDE DIKE LINER COVER SECTION UGE IIZED PLAN METAL I I I I I I I I I I I I I I I I II\ 1/2" HEM SAME SIDE (TYPICAL) DIKE WALL FACING SECTION ISOMETRIC NOT TO SCALE I I I I I I I I I I I I I I I I I I I I LDED TAB TENSION RECORD DRAWING THESE DRAWINGS HAVE BEEN PREPARED FROM MARKED -UP DRAWINGS SUPPLIED BY THE CONTRACTOR. AN AS -BUILT SURVEY HAS NOT BEEN CONDUCTED. FIELD VERIFY ANY INFORMATION CONTAINED HEREON BEFORE USING. Q M CO 0 Z o N 044 o W Q W DRAWN BY: EE CHECKED BY: GMO DATE: 11 / 15/07 JOB NUMBER: 05-756 SCALE: AS SHOWN DRAWING TITLE: TIMBER CONTAINMENT DIKE DETAILS SHEET: OF c 10