Loading...
HomeMy WebLinkAbout05-756 C-11RECORD DRAWING THESE DRAWINGS HAVE BEEN PREPARED -FROM MARKED -UP DRAWINGS SUPPLIED BY -------------- THE CONTRACTOR.---AIt-AS--BUILT -SURVEY HAS NOT BEEN CONDUCTED. FIELD VERIFY ANY INFORMATION CONTAINED HEREON BEFORE USING. Iq UNALAKLEET TOWNSI TE PLAT 87-11 EDGE OF ROAD -------- ----� ---- CENTERLINE OF RIGHT-OF-WAY BEACH ROAD EAST F� HRR & HRS — HRR TO SCHOOL — — HRR_� — HRR HRR 11r EDGE OF ROAD - HR II \HRS HRS HRS HRS I HRS — OH/E — — OH/E\ =T OH/E T — — — — ,, i ------ — --- �� T - - - FO T T l FO FO FO I\ / WA TER MAIN FROM inin rcR VT UNALAKLEET TOWNSI TE PLAT 87-11 TO FIRE f SPRINKLER RISER "T'NG REMOTE TOR s WASTE HEA T n UTILIDOR I DIKE ACCESS STAIRS 0 - REMOVE FENCE I o . REMOVE EXISTING DIKE "N� N r WALL AND 6.0' HIGH LnIN CHAIN LINK FENCE -- — — — — — — — — — — — — —I — — — — — — — DRAIN EXISTING 180,000 GALLON TANK AND RELOCATE UVEC SPILL I INSTALL BLIND FLANGES RESPONSE ON TANK SHELL VALVES. CONTINGENCY TANK DECOMMISSIONING STORAGE TANK OF THIS TANK IS ADDITIVE ALTERNATE A I I 1 I I I DECOMMISSIbN EXISTING TANKS NEW TANK PRVIDED BY CHANGE OkiDER I >ULKTA , 600 ON I I 1 -5 I FUEL TANK 180,00 GALLON —3 — — — — — 1 — — 3-0 J 36'0X24'-0" HIGH I PO WEj FINI SF ELEVI HRS 0 HRR & HRS TO BALER BUILDING HRR — — — N 735354" E� 147.18' -- - — HHS NOTES: DRAIN AND REMOVE TANK FARM MANIFOLD PIPING, VALVES AND FITTINGS. REMOVE INSULATED PIPE UTILIDOR AND 314"0 COPPER GENERATOR JACKET WATER HRS AND HRR PIPING BETWEEN POWER PLANT AND 180,00 GALLON TANK, ISOLATE AND PROTECT HRS AND HRR PIPING INSIDE POWER PLANT FOR RECONNECTION TO NEW HEAT TRACE COIL. nAIN, VAPOR FREE EXISTING 88,600 GA PRIOR TO LOCATION. PERFORM INSPECTION OF EXISTING NKS IN ACCOR AP1-653. S -2 FOR LIST OF REPAIRS QUIRED AND SHEET M-5 FOR TANK MODIFICA .. :� DRAIN, CAP AND ABANDON IN PLACE EXISTING 4"0 ABOVE GRADE MARINE --- --- - -- HEADER PIPING AND BELOW GRADE PIPING TO POWER PLANT. 4� EXISTING STEEL DIKE WALL MATERIALS SHALL BE REUSED TO CONSTRUCT NEW CONTAINMENT DIKE. PROVIDE NEW MATERIAL WHERE EXISTING MATERIALS CAN - HRR NOT BE REUSED. (SEE SHEET C-12) HRR ' / _ _ _ HRF 5. REMOVE EXISTING DIKE LINER AND BALLAST MATERIAL. REGRADE AND COMPACT HRS � HRS EN TIRE SI TE. ---------- CH /E UNALAKLEET TOWNSI TE PLAT 87-11 PROVIDE PIPE SUPPORTS A MAXIMUM OF 10.0' ON CENTER, SUPPORT FROM BUILDING AND FROM GROUND ON TIMBERS ATT SATELLITE DISH EXISTING EAST / DIKE WALL AND 88 600 GALLON FENCE TO REMAIN 8 00 OON TANK N TANK NO. PP 1 I 4 . I � �� ` (25.25 '0 X 23'- 8 " HIGH) (25.25 '0X23'- 8 " HIGH) I >REA8,6002,K 1O C -12 ) r - S 72 33'18" W F- - - - - - - - - - - - - - - - - - - - - - - - - - - 137.63 1 ER PLNT TANK REMOVAL PLAN SCALE: 1 " = 10' / FO FO \ \111 \\ \ \ \ I IIIII \\ \ I I I I III \\ \ I I I I IIII \\\ I I I I IIIII \\\\ I I I IIII \\ I I I I IIIII \\\\ I I I I I III \\\ IIII // UNALAKLEET TOWNSI TE PLAT 87-11 / / I 1 1 1 1 1 5 1 I I I 5'1 I\\ I I \ \ \ \ GCI I I I I I \\\\ I I I I I I \\\\ I I I I \ \ IIII I I I I \ \\ \\ 1 I I I I I SHED / / I SHED / - - / / i 0 10' 2 0' l SCALE IN FEET 4 "0 ABOVE GRADE PIPING I TO MARINE HEADER ON BANK OF KOUWEGOK SLOUGH, PIPING EXTENDS APPROXIMA TEL Y 100 FEET FROM THIS LOCATION Id c c `s c c Ll u a) 0? W 0 �: z 0 W IIM > IZQ W DRAWN BY: EE CHECKED BY: GMO DATE: 11 / 15/07 JOB NUMBER: 05-756 SCALE: AS SHOWN DRAWING TITLE: UVEC TANK FARM REMOVAL PLAN SHEET: OF c - 11