NOTES: \
DRAIN EXISTING 500 GALLON TANK, DISCONNECT ALL PIPING AND INSTALL PIPE
PLUGS IN ALL TANK OPENINGS. DRAIN AND REMOVE F.O.S. AND F.O.R. PIPING
BETWEEN TANK AND SCHOOL DUPLEX. \
P:� DRAIN EXISTING 300 GALLON TANK, DISCONNECT ALL PIPING, INSTALL PIPE \
PLUGS IN ALL TANK OPENINGS. DRAIN AND REMOVE F.O.S. AND F.O.R. PIPING
BETWEEN TANK AND SCHOOL DUPLEX.
3. INSTALL SUPPLY TANKS SUCH THAT TANK VENTS TERMINATE 10 FEET \
MINIMUM FROM BUILDING OPENINGS (DOORS AND WINDOWS). \
4� PROVIDE FOUR (4) NEW 1/2" O.D. TYPE L HARD DRAWN COPPER F.O.S. AND
F.O.R. PIPES WITH WROUGHT COPPER FITTINGS FROM NEW SUPPLY TANK TO
EXISTING DUPLEX. CONTINUOUSLY SUPPORT PIPING ON UNISTRUT BETWEEN _
TANK AND BUILDING. RACK PIPES ON UNISTRUT SUPPORTS ATTACHED TO
DUPLEX EXTERIOR WALL. _
CONNECT NEW 1 /2 " O.D. COPPER F.O.S. AND F.O.R. PIPES TO EXISTING 1 /2 " -
O.D. COPPER PIPING OUTSIDE OF DUPLEX.
COVENANT
SUBDI VISION
PLAT 87-3
(FORMERL Y
USS 800)
0
0
O
�
Z
0
\ Q
W
Z
- o
W
\ _ z
5 00, Q
N 73.2 � - 0 20 40
_ 15g.72 Y
- 1
SCALE IN FEET
/ o
o�
/ OH/E
� I
OH/E —
USS 1535
US SCHOOL RESERVE
I
- - \ 244.20' EDGE OF ROAD \
SCALE: 1 " = 20'
\ USS 3553
\ I
\ \ 9
O
\ 114', \
\ I USS 1535 ROAD i EXISTING BSSD SCHOOL I
- - - \ EDGE OF BULK TANK FARM WITH
\ EXISTING 2 TANKS, I \
Z I PRIVATE BELOW GRADE DECOMMISSIONING OFj\
oow RESIDENCE I PROPERTY CORNER FUEL PIPING EXISTING TANKS IS \\
N 248044.22 l— (TYPICAL) ADDITIVE ALTERNATE
N WO I —
� CONNECT NEW 1/2" SCHOOL E 353153.00 N77°53'49"E— � \
F. 0. S. TO EXISTING HOUSING - _ 78.06 \ I
1/2"F.0.S. INSIDE (DUPLEX)
\ N77°5E -
CABIN 4�
EXISTING DUPLEX 49 4.1S N7753
\ � _- --- 26.63 CABIN
1 PROVIDE NEW � - - � ?,
1, OLIO GALLON - �'< \
—� CATHODIC PROTECTION 4 �,\� \ DISCONNECT EXISTING
M - 8 SUPPL Y TANK ---
SYSTEM ANODE (TYPICAL) -15 cA \N \ \ 1-1/4 0 FUEL PIPING,
PROPERTY LINE � - / o
\ � COMPLETELY REMOVE ALL
TO BE VACATED
N 7 7 °51OO - ------------ -
\ BY BSSD - 1 5
__ FUEL, CAP ENDS AND
27 33 ABANDON IN PLACE
- ------ 2
- I'(
C18LOT 3
(SIMILAR)21'49� E SCHOOL h 1/2" SCHEDULEN71g9 HOUSING 160 BELOW j \
/ (DUPLEX) GRADE FOS PIPING vZ
9<:�
v LOT 11 \
N6515' 6 \ z
25 \ , C
UNALAKLEET TOWNSITE \N
0, PLAT 8 7-11 A \
O\O
I
J
USS 3553
RECORD DRAWING
THESE DRAWINGS HAVE BEEN PREPARED
FROM MARKED -UP DRAWINGS SUPPLIED BY
THE CONTRACTOR. AN AS -BUILT SURVEY
HAS NOT BEEN CONDUCTED. FIELD VERIFY
ANY INFORMATION CONTAINED HEREON
BEFORE USING.
O
O
N
w
Lu
a
co
W
DRAWN BY: EE
CHECKED BY: GMO
DATE: 1 1 / 15/07
JOB NUMBER: 05-756
SCALE: AS SHOWN
DRAWING TITLE:
BSSD STORAGE BUILDING
AND HOUSING SITE PLAN
SHEET: OF
C-16