Loading...
HomeMy WebLinkAbout05-756 C-93 C-9 4 EXTERIOR DIKE C-10 (TYPICAL) 46,600 I 46,600 GALLON TANK I GALLON TANK 21 '0 X 18' HIGH I 21 '0 X 18' HIGH 1 SLOPE I I F IN TERIOR DIKE 5 (TYPICAL) C-10 46,600 GALLON TANK 21 '0 X 18' HIGH 46,600 46,600 46,600 46,600 GALLON TANK GALLON TANK GALLON TANK GALLON TANK FINISH 21 '0 X 18' HIGH 21 '0 X 18' HIGH 21 '0 X 18' HIGH 21 '0 X 18' HIGH GRADE MAXIMUM SIDE SLOPE 1 %1 S� (TYPICAL) 2.5 ,It THERMOSYPHON LOOP EXISTING \ , RIGID INSULATION GRADE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - — -- TANK FARM SECTION SCALE: 1 " = 15' LANDFILL ROAD EXTEND RIGID INSULATION TO EDGE OF PAD AND TO LAND FILL ROAD AT ACCESS POINTS FINISH 4 EXTERIOR DIKE GRADE C-10 (TYPICAL) 1.2% SL OPE I I EXISTING GRADE C-9 SCALE: 1" = 15' SECONDARY CONCRETE RING WALL MEMBRANELINER \ TANK 3 WASHED BEDDING 1 3 BELOW BOTTOM OF TANK \ PROVIDE 4: 1 SLOPE COMPACTED SELECT FILL \ \ / A WA Y FROM TANK FOR 2 FEET \ 3" BEDDING ON TOP OF LINER 1 \ NON —WOVEN GEOTEXTILE \ PRIMARY MEMBRANE LINER / NON —WOVEN GEOTEXTILE / \ \ �-3" BEDDING UNDER LINER / _SECONDARY MEMBRANE LINER 4" RIGID INSULATION fifi �� 1Ilk SCALE: 1 " = 5' 89,000 GALLON TANK 25'2"0 X 24' HIGH NO TE: PAD CONSTRUCTION TO ELEVATION 17.17' INCLUDING THERMOSYPHON BY OTHERS, EXCEPT FOR PAD EXTENSION FOR SPILL RESPONSE CONNEXS (SEE SHEET C-2). — — --- — -- 957o UI- MAXIMUM ULNSI I Y - THERMSYPHON LOOPS 46,600 GALLON TANK 21 '0 X 18' HIGH NON-WOVEN GEOTEXTILE PRIMARY MEMBRANE LINER NON -WOVEN GEOTEXTILE ELEV. = 17.75' (LINER) ELEV. = 17.5' (TOP OF INSULATION) ELEV. = 16.3' (BOTTOM OF PIPE) THERMOSYPHON LOOP, BED IN 6 " OF BEDDING (TYPICAL) 46,600 GALLON TANK 21 '0 X 18' HIGH RIGID INSULATION 46,600 GALLON TANK 21 '0 X 18' HIGH THERMOSYPHON 4 CONDENSER C-19 MAXIMUM SIDE SLOPE 1% SLOPE (TYPICAL) 2.5 �1 THERMOSYPHON LOOP RECORD DRAWING THESE DRAWINGS HAVE BEEN PREPARED FROM MARKED -UP DRAWINGS SUPPLIED BY THE CONTRACTOR. AN AS -BUILT SURVEY HAS NOT BEEN CONDUCTED. FIELD VERIFY ANY INFORMATION CONTAINED HEREON BEFORE USING. VERIFY SCALES BAR IS ONE INCH ON ORIGINAL DRAWING 0 1' IF NOT ONE INCH ON THIS SHEET, ADJUST SCALES ACCORDINGLY. W z W Q M ��GG CO O O N Lu H U) Lu co N Lu l a) 0 W O3: 6 044 o LA 3" OF WASHED BEDDING Lu 0 BELOW BOTOM OF TANK SELECT FILL COMPACTED TO 95% OF MAXIMUM DENSITY SECONDARY 89,000 GALLON TANK MEMBRANE LINER 25'2"0 X 24' HIGH CONCRETE 1 RING WALL C— 6 1 C-19 PROVIDE 4: 1 SLOPE 2.0' AWAY 1 FROM CONCRETE RING WALL I � cl� DRAWN BY: EE 14.0 ELEV = 15, 0' (TOP OF RING WALL) 6" SURFACE CHECKED BY: GMO I COURSE 1 DATE: 11 / 15/07 1N JOB NUMBER: 05-756 --- ELEV. = 12.5' SCALE: AS SHOWN (LINER) DRAWING TITLE: LIMI TS OF 3" OF BEDDING ABOVE NON -WOVEN GEOTEXTILE EXCAVATION AND BELOW LINER PRIMARY MEMBRANE LINER TANK FARM SECTIONS NON -WOVEN GEOTEXTILE NO TE. DO NOT EXCAVATE BEYOND THE LIMITS SHOWN UNLESS DIRECTED BY THE ENGINEER. NOTIFY ENGINEER TEN (10) DAYS IN ADVANCE IN WRITTING FOR INSPECTION OF THE BOTTOM OF THE EXCAVATION. COMPACT EXISTING SUBGRADE PRIOR TO PLACING BEDDING MATERIAL AND MEMBRANE LINER. SHEET: OF 4 � R� � T� N -9 SCALE: 1" = 5' c g