Loading...
HomeMy WebLinkAbout05-756 M-140 LC) L ('o r U-BOL T 1/4" PLATE 4"0 PIPE 11/16"0 HOLE FOR 2 1/2" 2 1/2" 0 3/4"0 X 4" LAG BOLT (TYPICAL OF 2) C5X9 11/16"0 HOLES o — — — — — CHANNEL (TYPICAL OF 4) 2" 2" 0____ l'-6" 1" 1" SECTION A -A SECTION B-B 1/4" PLATE B rn I 4"0 PIPE (TYPICAL) 1/4" THICK X 2" WIDE UHMWP PIPE SLIDE (TYPICAL) LOOSE FITTING U-BOLT WITH DOUBLE NUTS, FLAT WASHERS AND LOCK WASHERS (TYPICAL) �} L7UJJC I l-'LH IC C 5X9 CHANNEL (TYPICAL) (TYPICAL) l'-9" X 5" X 3/8" B N THICK PL A TE 11/16"0 HOLE FOR 3/4"0 X 4" LAGS NOTE: (TYPICAL OF 4) ALL MATERIALS SHALL BE HOT DIP GALVANIZED. DOS WALL PIPEE RT SCALE: 1" = 1' 6x6 PREE TREATED PIPE GAL V PIPE STRAP ONE NOMINAL PIPE SIZE LARGER THAN PIPE. ATTACH TO TIMBER WITH (2) GAL V LAG BOLTS USE SCALE: 1" = l' 6x6 PRESSURE TREATED TIMBER SCALE: 1" = 1' 9s PIPE 6 " SURFA SCALE: 1 " = 5' W 4� SCALE: 1 " = 5' SECONDARY MEMBRANE LINER 4" RIGID INSULATION 6" SURFACE COARSE SCALE: 1 " = 5' RECORD DRAWING THESE DRAWINGS HAVE BEEN PREPARED FROM MARKED -UP DRAWINGS SUPPLIED BY THE CONTRACTOR. AN AS -BUILT SURVEY HAS NOT BEEN CONDUCTED. FIELD VERIFY ANY INFORMATION CONTAINED HEREON BEFORE USING. GAL V PIPE STRAP ONE NOMINAL PIPE SIZE LARGER THAN PIPE. ATTACH TO TIMBER WITH (2) GALV LAG BOLTS (TYPICAL OF 2) GRAVEL FILL COMPACTED TO 957. MAXIMUM DENSITY 19.5' L NOTES B-LINE FIGURE B2100 PIPE STRAPS AND LAG BOLTS WITH ASTM A- 123 G90 HOT DIP GALVANIZED COATING. PROVIDE (2) 3/8"0 X3- LAG BOLTS FOR PIPES 2"0 AND LARGER AND (2) 1/4"0 X 2- LAG BOLTS FOR PIPES SMALLER THAN 2 20.0 SUMP WITH 3- X 3/8- HS-20 LOAD RATED HOT DIP GALVANIZED STEEL BAR GRATE AND HOT DIP GALVANIZED ANGLE IRON FRAME EMBEDDED IN CONCRETE. REMOTE IMPOUND TRUCK CONTAINMENT SUMP SHALL BE MADE FROM ASTM A36 STEEL. ALL CONNECTIONS SHALL BE CONTINUOUSLY WELDED UNLESS OTHERWISE INDICATED. ALL CORNERS AND PLATE SECTIONS SHALL BE CONTINUOUSLY CONTROL JOINT WELDED AND LIQUID TIGHT. SUMP SHALL BE UNCOATED AND INSTALLED WITH TWO 17 POUND SACRIFICIAL ANODES. SUMP COVER SHALL BE GALVANIZED SHEET METAL AND TOUCHED UP WITH COLD GALVANIZING COMPOUND. (TYPICAL) 4 9 5.0' X 5.0' X 6" THICK REINFORCED CONCRETE APPROACH SLABS AT EACH END NOT SHOWN. -14 STAINLESS STEEL HINGED COVER WITH LATCH, PIANO HINGE 5 SECTIONS EQUAL LENGTH 12 GAUGE GALVANIZED SHEET ME TA STAINLESS STEEL L A TCH---\ 6" SURFACE COARSE GRAVEL FILL COMPACTED TO 957. MAXIMUM DENSITY SECONDARY MEMBRANE LINER 4" RIGID INSULA TION 19.32' EXPANSION JOINT MATERIAL WITH FLEXIBLE SEALANT 19.5' -SUMP 6" THICK CONCRETE APPROACH SLAB WITH #5 REBAR 12" O.C. EACH WAY, TYPICAL EACH END #5 REBAR 20.0' (TYPICAL) o I 19.32 L 3X3X3/8" ANGLE - — - I I 2� STEEL BAR �, • I GRA TE L F_ 1 ALL PLATEA�/16" �2"-12" 1 I TO ANGLE-12' 1 �- L 6X4X3/8" I 3-3/4" • 1 L 3X3X3/8" ANGLE I 1 N SUMP _� I - I 1 I ^ L 3X3X3/8" END ANGLE 1 • 17.82' • 4. 0' L 3X3X3/8" INTERMEDIATE ANGLE Iff TD N SCALE: , 112 FL EXIBL E FUEL RESISTANT SEALANT CON TROL JOIN T 5.0' MA TERIAL 1/4 1/2"x1 1/JO FINISH 2q GRADE CONTROL JOIN T #5 REBAR 12" 0. C. EACH WAY 9 TR 0 L 0 N T DEETL 34'- 0" SCALE: NONE EQUAL EQUAL EQUAL EQUAL , EQUAL rz----------------- - F — — — — — — — — — — — — — — — — — -T----------------- ----------------- ----------------- I 8"OX6" DEEP I SCHEDULE 40 PIPE 1/4" PLATE I L3X3X3/8" CORNER, L3X3X3/8" SUMP WITH 3/8 " SUMP WA L S 1 1 I 1 PERIMETER, AND END ANGLE INTERMEDIATE ANGLE (TYPICAL OF 4) PLATE BOTTOM 1/4" PLATE 1 1 I FLOOR 1 I 16" ALL ANGLE - I I /16" CONNECTIONS 2'-0" 1 ----------------- ----------------- -L----------------- - - - - - - - - - - - - - - - - - JU - - - - - - - - - - - - - - -- 5/8"OX3" S3L NELSON STUDS 1.0' 16-0" EQUALLY SPACED @ 18" 0. C. ' VIE /�E w (TYPICAL PLAN L 6"X 4"X3/8" EACH END) n L3X3X3/8" -14 INTERMEDIATE ANGLE (TYPICAL OF 4) =L — — — — — — — — — — — — — — — —F — — — — — — — — — — — — — — — — — — —— — — ——— — — — — — — — — — — — — — — — — ————————————————— `i I 11r---=---z---�--�—r-- r---=---z—�---r�LrTz'T14-----r---T---_w I 1/4" PLATE1 1 1 L3x3x3/8" I°' I1INTERMEDIATE ANGLEI---------------1--------- - - - --L--------- -------L------------------L------------------ CONTINUOUS 3/16" (TYPICAL) GRAVEL FILL COMPACTED ANDV VOID FOR WI BEDD�NGSFROM EACH EL E VA TION VIE W TO 95% MAXIMUM DENSITY SIDE AFTER PLACING SUMP 3" BEDDING SCALE: 1 " = 2' 0 N VERIFY SCALES BAR IS ONE INCH ON ORIGINAL DRAWING 0 1" IF NOT ONE INCH ON THIS SHEET, ADJUST SCALES ACCORDINGLY, M O Z a W Z W a U) a J a W a Y aQ � J a a w J ~ W W :) J LLY Ya J �a Z Q M CO Jm a di Em 0 L U Q 0 N W co uj co Lu U) to DRAWN BY: EE CHECKED BY: GMO DATE: 11 / 15/07 JOB NUMBER: 05-756 SCALE: AS SHOWN DRAWING TITLE: MECHANICAL DETAILS SHEET: OF M-14