HomeMy WebLinkAbout05-756 M-150� o L rz� r 4"0 SCHEDULE 80 UVEC TRANSFER • LINE FROM BULK TANK FARM 4" CHECK VAL VE 4"X4" TEE WI TH PIG 9 BARS —15 4"0 FULL PORT BALL VAL VE DIKE WALL 4" BLIND PIPE SUPPORT 2 FLANGE�(TYPICAL OF 2) —14 i 3 PIPE SUPPORT —15 (TYPICAL OF 2) 6 BOLLARD o C-18 (TYPICAL OF 4) NOTE: INSTALLED CONFIGURATION MODIFIED, SEE SHEET C-12 SCALE: 1 /4" = 1'-0" SCALE: NONE CPS TYPE 'TC' MASTIC CPS THERMI T READY CAP — CAD WELD SCALE: NONE UVEC POWER PLANT TANK (TANK No. PP1) PRESSURE RELIEF VAL VE INSULA TED ANODE LEAD WIRE PIPE COATING PIPE WALL CUTBACK AREA FOR PIPE COATING 314"0 X 9" LONG PIPE BUSHING FOR ADJUSTABLE PIPE STAND WELDED INPL ACE TO END PLATE — „ w wa 3/8"Ox6" GAL VANIZED LAG BOLT (TYPICAL OF 8) .5r, "0 SCALE: 1" = 1'-0" GRINNEL FIGURE 191 ADJUSTABLE PIPE STANCHION WITH U—BOLT AND ADJUSTING NUT 6 "X6 "X3/8 " BASE PLATE 1 /4 318"Ox3.5" GAL VANIZED LAG BOL T (TYPICAL OF 4) 4x 12 PRESSURE TREATED TIMBER INSTALL SO TOP OF LOWER TIMBERS ARE FLUSH WITH FINISH GRADE (TYPICAL) ,0 SCALE: 1 /2" = 1'-0" / 6 l THICK X 2" WIDE PIPE SLIDE 4 "X 114 "X 1. 0' TO FI T U—BOLT WITH NUTS, WASHERS DCK WASHERS 314 " THREADED CAP OR PLUG RECORD DRAWING VERIFY SCALES „ 3/4 THREADED THESE DRAWINGS HAVE BEEN PREPARED BAR IS ONE INCH ON BALL VALVE FROM MARKED -UP DRAWINGS SUPPLIED BY ORIGINAL DRAWING THE CONTRACTOR. AN AS -BUILT SURVEY O 3/4" THREAD—O—LET HAS NOT BEEN CONDUCTED. FIELD VERIFY IF NOT ONE INCH ON ANY INFORMATION CONTAINED HEREON THIS SHEET, ADJUST SCALES ACCORDINGLY, PIPE BEFORE USING. BEFORE USING. EXISTING GROUND �o o o ° 0 0 O t 0 0 BACKFILL WITH EXCA VA TED p 0 ° oo ° \\ MATERIAL OR IMPORTED GRAVEL ° FILL, COMPACTED TO 95% ° o MAXIMUM DENSITY ° o o O p o O / p O 0 00 ° O O ° O O p - - -.o - o- o 0 0 0._ o e 5 CAD WELD 15 (TYPICAL) %\ 0 0 ` 0 o ° 0° 0 \/� o 0 ,\ o 0 0 0 o p o ° 0 0 0° COA TED /\\\\/\\/\\/\\/\\/\\/\\/\\/\\/\\/\\/\\ 0 ° o 0 0 ° STEEL PIPE ° ° NOTE: % ° p o° o 0 0° c ONE PIPE SHOWN. 1, 2, OR 3 i\\/ ° PIPES MAY BE PRESENT\\ o ° ° o a ° DEPENDING ON LOCATION. 3 PIPES j\� ° ° °p ® o ° °o WOULD REQUIRE SIX ANODES, TWO i\/ ° FOR EACH PIPE. j�\/ 0 0 00 ° o ° O o 0 0 o 0 O p O / ° O ° o F o° ° p O SCALE: NONE WIRES SHALL BE PLACED WI TH SUFFICIENT SLACK TO PERMI T DIFFERENTIAL MO VEMEN T (2) 17# MAGNESIUM ANODE A T MID POINT OF BURIED PIPE, OR INSTALL A T ± 700' INTERVALS SCALE: 3" = l'—O" O Z a PRESSURE GAUGE OR PRESSURE VACUUM GAUGE ptB cn 0 4 " THREADED LL VALVE 0 Z O 4" THREAD—O—LET 04 Z 0 PIPE Lu 0 La l ,\ SCALE: 3" = l'—O" 1-114" X 114" FLAT BAR COPE BAR EDGES TO BE SMOOTH AND FLUSH WI TH INSIDE DIAMETER SCALE: 3" = l'—O" FLAT BAR TO BE CENTRALL Y L OCA TED IN BRANCH 4"X3" TEE r' 1 T BARS TO EQUALLY ACED IN ANCH 4"X4" TEE OR M Q CO DRAWN BY: EE CHECKED BY: GMO DATE: 11 / 15/07 JOB NUMBER: 05-756 SCALE: AS SHOWN DRAWING TITLE: MECHANICAL DETAILS SHEET: OF M-15