HomeMy WebLinkAbout05-756 M-2UVEC
POWER PLANT
TO POWER
PLANT
2 "o TANK #PP 1
:—�101 89, 000 GALLON
81 DIESEL #2 �
MARINE
(DHEADER
N
TEE WI TH BLIND
FLANGE AND
PIG BARS
4" BLIND
FLANGE ��IF
21
LOW POINT DRAINS ON
C-18 ALL TWO PIPELINES
(TYPICAL OF 2 LOCATIONS)
J 78 78
74 2 " 0 O 26 2»0 O 16 2"0 O 26 2"0 O 16
110114 "0 DIESEL mIio1 T T
79 4"0 GASOLINE L�
11 A111111
11 �� FULL PORT
BALL VALVES ON BARGE
OFF-LOADING PIPELINES
(TYPICAL OF 10)
CAM LOCK
FITTINGS
SCALE: NONE
N
>, C
oc
L L
E
c
5-: c
m
N L
r
`. L
r\ c
0
L
N`
Lil
Q c
o c
c� c
Z<
C
� C
O F
J _
UNALAKLEET VALLEY
ELECTRIC CORPORATION
BERING STRAIT
SCHOOL DISTRICT
WEST COAST
AVIATION SERVICE
UNALAKLEET
NATIVE CORPORATION
TANK #1
46, 600
72
TANK #4
46, 600
42
TANK #7
52
TANK #15
62101
TANK #19
TANK #23
101
OI
OI
46, 600
(]D3
OI
46, 600
46,600 OI22OI
46,600
GALLON
72
GALLON
GALLON
"A
GALLON
"A"
GALLON
22
GALLON
DIESEL #2
DIESEL #2
JET
JET
FUEL OIL
FUEL OIL
2" TANK RELIEF
BLIND
FLANGE
SET
VALVE (TYP
OF 11)
FLANGE`
H
TANK #2
3
3
TANK #5
3
TANK #8
TANK #12
3
TANK #16
3
TANK #20
3 12
3
TANK #24
46,600
101
Iol
46, 600
101
46, 600
46, 600
101
46, 600
101
46, 600
101
Io1
46, 600
GALLON
72
72
GALLON
42
GALLON
GALLON
GALLON
62
GALLON
( 22
( GALLON
DIESEL #2
DIESEL #2
JET "A"
AV GAS
52 -
JET "A"
FUEL OIL
L
UNLEADED
BLIND
FUTURE JET
FLANGE
"A " TANK
FLANGE
UVEC PUMP
SET
ENCLOSURE
72
52
"
TANK #3
4"
3"
TANK #6
32 3"
TANK #9
TANK #13
3"
TANK #17
3"
3"
TANK #25
1 RELIEF
89, 000
IOI
IOI
46, 600
IO
46, 600
46, 600
IOI
46, 600
IOI
IOI
a
46, 600VALVE
SET AT
GALLON
72
GALLON
GALLON
GALLON
GALLON
"A"
22 l-
A
GALLON125
PSI
DIESEL #2
DIESEL #2
FUEL OIL
AV GAS
JET
UNLEADED
4"X3" REDUCER
O 76
75
N0
= =
SAMPLE
PORT
TANK #10
TANK #14
TANK #18
TANK #22
'
TANK #26
O
T
I P
AA P
(TYPICAL OF 3)
OI
32
46, 600
GALLON
FUEL OIL
46, 600
GALLON
AV GAS
101
52L
101 89, 000
GALLON
JET "A"
89, 000 101
GALLON
FUEL OIL 9z
OI
12
46,600
GALLON
UNLEADED
IoIWVI
� — 101
74
DP-1
4"X3"
REDUCER
N 3" 62
22 3" 9z 9z
11 15
O 73 10 MESH
71 9z
41 qzq� N
31
N
- I 9Z
n 61
25 21
on BASKET
STRAINER P
<r O
4„
N
O 0 4„
51 �O
— 4»
N �O^�T
NI4"
24 O O
101
101
OI
IOIP
O 17
I
I
I
llm�,loli
64
»1
1
EXPANSION
JOINT A T � PRESSURE g PRESSURE GAUGE
1 BRIDGE _ 1 TEST -15 (TYPICAL)
CONNECTIONS
C-2 (TYPICAL OF 2)
g TEE WITH PIG BARS
-15 (TYPICAL OF 11)
BLIND FLANGES AND BALL
VALVE FOR FUTURE
FIL TRA TION EQUIPMENT
(TYPICAL OF 3 LOCATIONS)
9 � � TEE WITH PIG BARS g
T
R
FULL PORT
BALL VAL VE
6 PIG
1 CA TCHER 2
6„ (TYPICAL) M - 2
14 6 X4
ECCEN TRIC
REDUCER
(TYPICAL)
1 'a ' PUMP SUCTION
_ N d PRESSURE/VACUUM
I OEM I o 33 I OEM i o 63 i o 23 1 0 13 AND DISCHARGE 8
a PRESSURE GAUGE -15
14-0 P do J-0 P P (TYPICAL)
O 44 70 O 65 100 MESH
Y-STRAINER
Ij Ij Ij (TYPICAL OF 6) Ij Ij TRUCK FILL
❑O ❑O ❑O❑ ❑O ❑O ENCLOSURE
(TYPICAL OF 6)
1" n 1" n 1" n 1" n 1" n V
JET "A" I FUEL OIL
BSSD
—6" BLIND FLANGE
1 112" DRAIN VALVE
Y AV L_UCENTRIC
REDUCER
PIG CATCHER DETAIL I
SCALE: NONE
AV GAS j I JET "A "
WCAS
FUEL OIL 1 UNLEADED
UNC
RECORD DRAWING
THESE DRAWINGS HAVE BEEN PREPARED
FROM MARKED -UP DRAWINGS SUPPLIED BY
THE CONTRACTOR. AN AS -BUILT SURVEY
HAS NOT BEEN CONDUCTED. FIELD VERIFY
ANY INFORMATION CONTAINED HEREON
BEFORE USING.
W
Z
W
W Q
� Y
Q
lz a
0 J
aQ
w
J ~
W W
:) J
LY
Ya
J.j
�a
oa Z
Q M
��GG CO
0
N
LLI
C)— U)
Lu
N
co
W
mi,co
to
to
a)
0
Z
03:
044 o
Z5
=oLLI
DRAWN BY: EE
CHECKED BY: GMO
DATE: 11 / 15/07
JOB NUMBER: 05-756
SCALE: NONE
DRAWING TITLE:
FUEL SYSTEM
PIPING SCHEMATIC
SHEET: OF
M-2