HomeMy WebLinkAboutE11i i i i i i i i L1 N AV GAS BULK TANK ALARM SILENCE PUSHBUTTON --———————— — — — — — — NO SCALE L1 SS-1, SS-2 CONTACTS POSITION ON OFF 1- X - INDICATES CONTACT CLOSED (SOUTHWEST DRIVE THROUGH AREA) ------ I n I I_EM-1_ T (NORTHEAST DRIVE THROUGH AREA) ------ SECURITY LIGHT 1 SS1 2 SELECTOR SWITCH AREA DRIVE THROUGH 1 SI t 2 LIGHTS SELECTOR SWITCH AV GAS BULK TANK HIGH LEVEL RESET AV GAS BULK TANK #11 HIGH LEVEL RELAY AV GAS BULK TANK #11 HIGH LEVEL LIGHT AV GAS BULK TANK # 12 HIGH LEVEL RELAY AV GAS BULK TANK #12 HIGH LEVEL LIGHT AV GAS BULK TANK 113 HIGH LEVEL RELAY AV GAS BULK TANK #13 HIGH LEVEL LIGHT AV GAS BULK TANK #14 HIGH LEVEL RELAY AV GAS BULK TANK #14 HIGH LEVEL LIGHT AV GAS BULK TANK ' HIGH LEVEL HORN/STROBE i i i FLOAT LEVEL ALARM SILENCE RELAY i ----------------------� SEE 1 /E10 FOR CONTINUATION CONNECTION IN CORPORATION CONTROL PANEL 'CP-531. _ - _ SEE 1/E10.---,' i RE2-3 I I CONNECTION IN AVIATION SERVICE CONTROL PANEL 'CP-4'_ -------� SEE 1 /E 10_ — I RE2-2 i E—i­-od 0 i L----_ _ —— J CONNECTION IN SCHOOL CONTROL PANEL 'CP-3'_ SEE 1/E10_--,," i RE2-1 0 0 I i L— — — — — — — — RE2 AUXILLARY EM LOCKOUT RELAY RE1 EMERGENCY SHUTOFF LOCKOUT RELAY PUSH -TO -TEST, _ TYPICAL r R1 PROVIDE WITH 2-POLE 20A CONTACTS R2 LOCAL EMERGENCY SHUT OFF ACTIVATED ALARM LIGHT, TYP_ SECURITY AREA LIGHTING CONTACTOR DRIVE THROUGH AREA LIGHTING CONTACTOR LABEL BREAKER AS: "MAIN DISCONNECT. TURN OFF BEFORE SERVICING PANEL_ - L1 N i i i i i i i I i i i i i i i i i i i GASOLINE BULK TANK ALARM SILENCE PUSHBUTTON i i L_---------------- NO SCALE REMOTE CIRCUIT BREAKER IN METERBASE. r _ - SEE 1 /E2 FOR SIZE. EQUIPMENT GROUNDING CONDUCTOR AND NEUTRAL CONDUCTOR_ SEE 1/E1. I I 0 0 - 30/2 o a -2 THERMOSTATIC HEATER SWITCH - � p j ---0� FAN N 20/ 1. 1g/1 SPARE /11-i j '15/1 CONTROL PANEL ENCLOSURE NO SCALE SECURITY DRIVE THROUGH LIGHTS W/ INTEGRAL PHOTOCELL_ AREA DRIVE THROUGH LIGHTS W/ INTEGRAL PHOTOCELL. WP, GFCI RECEPTACLE NO SCALE 10 GASOLINE BULK TANK i HIGH LEVEL RESET GASOLINE BULK TANK i #24 HIGH LEVEL RELAY i GASOLINE BULK TANK #24 HIGH LEVEL LIGHT i I GASOLINE BULK TANK #25 HIGH LEVEL RELAY GASOLINE BULK TANK #25 HIGH LEVEL LIGHT I I GASOLINE BULK TANK #26 HIGH LEVEL RELAY I i GASOLINE BULK TANK #26 HIGH LEVEL LIGHT GASOLINE BULK TANK HIGH LEVEL HORN/STROBE i i i i FLOAT LEVEL ALARM SILENCE RELAY i --------------------- SEE 1 /E10 FOR CONTINUATION COMMON CONTROL PANEL 'CP-6' SECURITY DRIVE AREA DRIVE THROUGH LIGHT THROUGH LIGHTS OFF ON OFF ON (D 0 EM STOP DRIVE THROUGH R Lo m w a a m Qc, Q Lo w r W W J Q J Q Z D W W�•. z N �fl- o ., zLu 0) 0 c zci� ..� ) L �a za CD 00 o Us U �Q Lo J N w WF Qto Q J U QU Ucm W cm cLN 40 OF AW o4 THf� o0 000ao aoo 0 0....... 00 �aoMo�a�o oa0000 o00 00o ao 00000 0000./ a CHANNING LILLO o° ®i a o E�(E%-10285 �Q A"r Aw Aw zb 41l DRAWN BY: CPL, NVL CHECKED BY: CPL DATE: 11 / 18/05 JOB NUMBER: K4193 SCALE: AS SHOWN DRAWING TITLE: COMMON CONTROL PANEL 'CP-6' SCHEMATIC DIAGRAMS AND DETAILS