HomeMy WebLinkAboutE7CP7-10 - } � INSTALL WP, GFCI RECEPTACLE . �,,r-'` . ♦ ' i .._P ' EM-5 BELOW CP-7, SEE 6/E2. A TANK CP7-0s --- �,� WP --CP7-06 FUEL DISPENSING . CONTROL PANEL `CP-7'_ • y SEE SHEET E12_ ,� ' BURIED' #2' B.C. . . . . . . . . . . . . . . . 'RODUCT 3ER' t D_ 1, , 'E7. 3,000 WATER PLANT . DUAL TANK. t . - - CP7 03 ��--- CP7-07 CP7-04 . ■ 5 � EEM-4 , l CP7-08 CLASS 1, DIV 1 'r^ BOUNDARY, IYP -- r 4 i err CLASS 1, DIV 2 BOUNDARY, TYP l- r CITY DISPENSING ELECTRICAL PLAN SCALE: 1/4" =1' - 9' THE AREA BETWEEN 5'-0" AND 10'-0" , . ' OF OPEN END OF FLAMMABLE LIQUID VENT .. ' , ' . ' . ' , ' . . ' IS RATED CLASS 1, DIVISION 2_ „ • , • , , .................................. 5' IN ALL DIRECTIONS FROM ............ . ..... . .. . .... ..'.'.'.'.'.'.'.'.'.'.'.'. . OPEN END OF FLAMMABLE LIQUID VENT .......... • • • • • ........ • . IS RATED CLASS 1, DIVISION 1 _ ... . . ........... ........ 10 FROM SHELL, ENDS, OR .. ............ .......... ..... • ..... • . . ROOF OF FLAMMABLE LIQUID TANK ," -� IS RATED CLASS 1, DIVISION 2. 5 .......... ..... , ... • ... • . TYPICAL EACH SIDE. ........... ..... . ,.... . ............. ................... • • 1,500 GALLON I 1 3,DGt3 GAf LON TANK 1,500 CALLON . . . . . . . . . . . . . . . . . UVL WED ! DIESEL ........... ....... # 1 ! ..•.........1.Q. - .0 ... .... . .,........I.......... NO SCALE ALL WORK IN THESE AREAS SHALL BE DONE IN STRICT COMPLIANCE WITH ARTICLES 500, 501, 514 AND 515 OF THE NATIONAL ELECTRICAL CODE. PROVIDE SEAL -OFFS ON ALL CONDUIT PENETRATING CLASSIFIED LOCATIONS AS REQUIRED BY CODE. THE AREA INSIDE THE DISPENSER ENCLOSURE IS RATED CLASS 1, 8° DIVISION 1. • THE AREA WITHIN 20' OF THE .. ' • . • DISPENSER, UP 18" ABOVE GRADE, ' , ' , ' AND THE AREA INSIDE THE DISPENSER BUILDING IS A CLASS 1, DIV. 2 HAZARDOUS LOCATION. 20,_0" ;.;.;.�.............. ....... . . . . . . . . . . . . . . . . . " ,,.......... .,.., 18 t EQUIPMENT SCHEDULE CIRCUIT TAG SOURCE DESTINATION HP AMPS VOLTS PHASE CONDUCTORS (CU, XHHW) SCHEDULE NOTES CP7-01 CP-7 GASOLINE SUBMERSIBLE PUMP SP-2 3/4 240 1 2#12, 1#12 G 1,2 CP7-02 CP-7 DISPENSER D-1 120 1 6# 12, 1 # 12 G 1,2 CP7-03 CP-7 LOW LEVEL FLOAT SWITCH GASOLINE TANK N/A 120 1 2#12, 1#12 G 1,2 CP7-04 CP-7 DISPENSER LIGHT 3 120 1 2# 12, 1 # 12 G 1,2 CP7-05 CP-7 DIESEL SUBMERSIBLE PUMP SP-1 3 4 240 1 A 12, 1 12 G 1,2 CP7-06 CP-7 RECEPTACLE 1.5 120 1 2 12, 1 # 12 G 1,2 CP7-07 CP-7 LOW LEVEL FLOAT SWITCH DIESEL TANK N/A 120 1 2# 12, 1 # 12 G 1,2 CP7-08 CP-7 EM-4 N/A 120 1 2# 12, 1 # 12 G 1,2 CP7-09 CP-7 EM-5 N/A 120 1 2# 12, 1 # 12 G 1,2 CP7-10 CP-7 SECURITY AREA LIGHT 1.5 120 1 2 8, 1 # 10 G 1,2,3 SCHEDULE NOTES: 1. PROVIDE SEAL -OFF AT CONNECTION AS REQUIRED PER CODE. 2. SEE 1/E12 FOR WIRING CONNECTIONS_ 3. CONTROL WITH PHOTOCELL AND SELECTOR SWITCH INSTALLED IN CONTROL PANEL. 1lzz< jr-UEL ni e NK I EXISTING GASOLINE TANK TO BE ABANDONED IN PLACE a GENERAL NOTES: A INSTALL ALL CONDUCTORS IN GALVANIZED RIGID CONDUIT. FIELD ROUTE AND SIZE CONDUIT TO ACCOMMODATE ALL CONDUCTORS PLUS 25% SPARE CAPACITY. 1/2° MINIMUM SIZE. B. SEE 2/E7 FOR HAZARDOUS AREA CLASSIFICATION. INSTALL SEAL -OFFS AND EXPLOSIONPROOF EQUIPMENT WHERE REQUIRED BY CODE. 1- PROVIDE AND INSTALL 1 "C, 3#8, 1 # 10 CU GND, XHHW TO NEAREST 120/208V OR 120 240V PANEL IN WATER PLANT WITH CAPACITY. PROVIDE AND INSTALL NEW 2P 30A BREAKER, LISTED FOR USE IN THE PANEL. LABEL BREAKER "FUEL SYSTEM CONTROL PANEL CP-7"_ FOR BIDDING PURPOSES, ASSUME 150 FT FEEDER LENGTH. 2. INSTALL TYPE `B' FIXTURE ADJACENT DISPENSER ON ENCLOSURE CEILING. INSTALL CLASS 1, DIV 2 LIGHT SWITCH ON ENCLOSURE WALL. 3. GROUND ROD, TYPICAL. SEE 2/E3 SIMILAR FOR GROUNDING DETAIL. CADWELD GROUNDING CONNECTOR TO TANKS, FENCE, AND PIPING. 4. SEE 3/E2 FOR LIGHT POLE DETAIL. 5. MOUNT EXPLOSION -PROOF EM-STOP +48" ABOVE GRADE ON DISPENSER ENCLOSURE STRUCTURE_ INSTALL NAME PLATE ABOVE. SEE EQUIPMENT LIST, SHEET E1. 6. REMOVE EXISTING UNC SUBMERSIBLE PUMP, DISCONNECT POWER AND CONTROL WIRING. 7. INSTALL NEW SUBMERSIBLE PUMP IN NEW UNC GAS STATION GASOLINE TANK. EXTEND AND RECONNECT POWER AND CONTROL WIRING I.A.W. APPLICABLE NEC REQUIREMENTS. 8. MOUNT FUEL SYSTEM CONTROL PANEL OUTSIDE OF HAZARDOUS AREA TO TIMBER SUPPORT POSTS- SEE 6/E2 FOR MOUNTING DETAIL. AinAl ''LINE TANK w / F— GAS STATION ELECTRICAL PLAN SCALE: 1 /4" =1' - 0 " EXISTING DIESEL TANK VERIFY SCAM BAR IS ONE INCH ON ORIGINAL DRAWING 0 IF NOT ONE INCH ON THIS SHEET, ADJUST SCALES ACCORDINGLY. • GV ui 9 W t•, zC-4 a zc) U) c Z N 1- O a� J to L 0)�e za 0 ui <o U s Va c wo J N wWw F zm Q O /< J V m V Q V Z WN 2N 0 Z cl) V) occ 0 0 W '`OF ����►Ztit � 1 AW A/ °- DgHT ... ... a °D°°°t°°i ° °°°°D°°°° °°°°°D � CHANNING LILLO ° .s EE-10285 w O ODOo00 4%, DRAWN BY: CPL, NVL CHECKED BY: CPL DATE: 11 /18/05 JOB NUMBER: K4193 SCALE: AS SHOWN DRAWING TITLE: CITY DISPENSER AND UNC GAS STATION ELECTRICAL PLANS AND DETAILS SHEET: OF E 7