HomeMy WebLinkAboutE8liffifflIoLiffl0sim MASTER POWER SWITCH. 00 E i o I � Q0 0) o o� N � �a N (D N Ql) LL C SS-1 THRU SS-3 Ll CONTACTS POSITION N i DI 1 i i-- 012 i POWER PLANT BULK TANK FARM EM STOP E E DISTRIBUTION PUMP DP-1 INPUT TO MTU I MTU INPUT I o o "RUNNING" INPUT TO MTU - - - - i MTU INPUT i NO SCALE EMERGENCY SHUTOFF LOCKOUT RELAY LOCAL EMERGENCY SHUT OFF ACTIVATED ALARM LIGHT, TYP. VALVE A-1 "FULLY OPENED" RELAY VALVE A-1 "CLOSED" RELAY VALVE A-1 POWERED "CLOSE" CONNECTION VALVE A-1 POWERED "OPEN" CONNECTION VALVE A-1 "OPENED" LIGHT VALVE A-1 "CLOSED" LIGHT FUEL SYSTEM "ON" LIGHT OPEN VALVE A-1 SIGNAL RELAY FROM POWER PLANT VIA RTU-1 DISTRIBUTION PUMP 'DP-1' "ON" LIGHT UVEC DISTRIBUTION PUMP 'DP-1' STARTER & OVERLOADS <R#�oM# 000NTROL RELAY / MOTOR STARTER o-- MOLDED CASE CIRCUIT BREAKER ` AA INDICATING LIGHT A = AMBER, G = GREEN 20/1 RATING & NO. OF POLES AS INDICATED. ' R = RED 20/1 IEC STYLE CIRCUIT BREAKER RATING POLES R PUSH -TO -TEST LED INDICATING LIGHT & N0. OF AS INDICATED. OL r- - - - - - - - -� 1 I MOTOR OVERLOADS ❑ REMOTE MOUNTED DEVICE I I C( i)D TIME DELAY RELAY L-----------i z - KEYED SELECTOR SWITCH (EXTERNAL OPERATOR) PB PUSH BUTTON (EXTERNAL OPERATOR) SS# 1 od 1-0 2 2-POSITION SELECTOR SWITCH Fo_1 TERMINAL BLOCK CONNECTOR R# od R NORMALLY OPEN CONTACT * 0-6 o NORMALLY OPEN FLOAT SWITCH ** °,�� NORMALLY CLOSED CONTACT Io NORMALLY CLOSED FLOAT SWITCH ** 0 0 NORMALLY OPEN MOMENTARY CONTACT PUSH BUTTON NORMALLY CLOSED MOMENTARY CONTACT PUSH BUTTON LABEL BREAKER AS: "MAIN DISCONNECT. TURN OFF BEFORE SERVICING PANEL". NOTES: * NORMAL POSITION OF RELAY CONTACTS IS WITH COIL DE -ENERGIZED. ** NORMAL POSITION OF FLOAT SWITCHES IS WITH THE TANK EMPTY. REMOTE CIRCUIT BREAKER IN METERBASE. SEE 1 /E2 FOR SIZE/TYPE. TTr � I I i I EQUIPMENT GROUNDING CONDUCTOR - - - - i AND NEUTRAL. � I I I 0 0 0 0 j N PROVIDE SELECTOR SWITCH, RATED 100/3 MAIN BREAKER TYPICAL. N / P1 PHOTOCELL MOUNTED --- ON SECURITY LIGHT POLE SEE 4/E2. 1 SS2 2 SECURITY AREA LIGHT N _ �--� 1 SS3 2 TANK FARM AREA 20/1 LIGHTS N _ i PUMP ENCLOSURE j LIGHT & LIGHT N SWITCH 15%1 - 15/1 SPARE 15/1 2(WP, GFCI RECEPTACLE N r----------------, i THERMOSTATIC HEATER SWITCH � Y� . 10/ 1 i �- r' FAN N I I 15/1 15/11 CONTROL CIRCUIT N -�-- SEE 1/E8 FOR ---- r - CONTROL CIRCUIT. .10/1 L- - - - - - - - J N /7� M 1-2 OL (3) fl I �-- F / ►'``� M i - 3 o o F M1-4 fl 90/3 CONTROL PANEL ENCLOSURE IFVEC TANK FARM CONTROL PANEL'CP-l'ONE-LINE DIAGRAM., NO SCALE MAIN TELEMETRY UNIT 'MTU-1' A J—I ACTUATED BAIL -r -- VALVE A=1 TRANSFER%/� PUMP D. POWER PLANT INTERMEDIATE TANK FILL: SEE INTERMEDIATE TANK FILL SEQUENCE, SHEET E9_ MTU CONTROL SCHEDULE INPUTS CONTROL FUNCTION DI RTU-1 (K1) BULK TANK FARM EM STOP ACTIVATED DI2 RTU-1 (K2) DP-1 RUNNING DI3 SPARE DI4 SPARE OUTPUTS K1 RTU-1 (DIt) DP-1 RUN REQUEST FROM POWER PLANT K2 SPARE K3 SPARE K4 SPARE DISTRIBUTION VALVE A- 1 PUMP D. ON OPEN CLOSED UVECTANKFARM CONTROL PAN EL'CP-l' FRONT VIEW 9 a 0 �d w M T 04 W O W ti ZC !► Z �•' c zN za � oui U= U �Fa LuLu o W'i N W� 05 Z0 Q 0 Q -i \ 0 —U i� W04 N ��`Nxlkx%I 11 41 °° °° AWAW ® �4 H y ICHANN G LILLO . / t 0 EE-10285 w '"W �� 1 I'%OFFSSV;`�o DRAWN BY: CPL CHECKED BY: CPL DATE: 11 / 18/05 JOB NUMBER: K4193 SCALE: AS SHOWN DRAWING TITLE: CONTROL PANEL 'CP-1' SCHEMATIC DIAGRAMS DETAILS, AND CONTROL LEGEND SHEET: OF E 8