Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Coating Certifications
BROWN-MINNEAPOLIS TANK CO. Brown -Minneapolis Tank - Northwest, LLC 1218 West Bay Drive Olympia, WA 98502 Phone: 360-352-7575 * Fax: 360-367-9937 www.bmt-tank.com June 15, 2005 Mr. Dave Schellenberger Hankal Construction, Inc. 550 West 54th Avenue Anchorage, AK 99518 Re: AIDEA — Unalakleet Bulk Fuel Tanks BMT-NW Order No. 21747 Dave, We have included a paint inspection schedule for review and approval based on our understanding of the project specification and addendums. This schedule was developed after a formal review with our independent NACE Certified Inspection firm Custom Coating Consultants, LLC and Stan Osborne of ICl/Devoe Coatings. As you will note there are frequent inspections and hold points by BMT paint inspection personnel and periodic inspection hold points by the NACE Certified inspection firm. Additionally ICl/Devoe will provide periodic inspections for quality control of their product performance guarantee. Please contact us with any questions or if you need any further information. Respectfully, BMT — Northwest, LLC /C L lte'_ � Bob Barnhart Project Manager Enclosure -'ORR PM .-swim ? BROWN;141INNIMPIDLIS TANK Co. BMT-NORTHWEST, LLC AIDEA - UNALAKLEET BULK FUEL TANKS HANKAL CONSTRUCTION, INC 21747 - PAINT INSPECTION SCHEDULE SMT (Brown-Minnapolis Tank - Northwest, LLC) 4U Z Lli ow o 46 z 4VV ,;usiom c;oatan t;onsuitants, L(:D LG . (D coo m U z� (9 2 ° (:D Cj 2 o co TANK NO./SIZE BMT CCC BMT CCC BMT CCC BMT CCC 1/46K ✓ �, _o Q. o N '� q�j U) ® a (D U Q 2146K ✓ ✓ 3146K ✓ ✓ 4146K ✓R ✓ �] 5/46K Q Q Q ✓Cl 6/46K 0 ✓ Q 7/46K ✓ Q Q Q 8146K Q 0 ✓Q ✓ ./ 9/46K ✓ ✓ IQ Q 0 10 / 46K © ✓ [J •/ Q 11 /46K Q Q Q 12/46K © ✓ ✓ ✓ 0 13 / 46K ✓ �✓ ® © ✓ 14 / 46K ✓ ✓ 15/46K Q Q 16 / 46K Q ✓ ✓[, Q 17146K �✓t Q © ✓ ✓ 18 / 46K ❑✓ ✓ © ✓ 19 / 46K ✓C]. ✓✓� 20 / 46K ✓ ✓ M] 21 / 46K ® ✓ ✓Q 22 / 46K ✓ ✓ Q []✓ 23 / 46K ✓ ✓ ✓[] ' 24 / 500 ✓ ✓ ✓ ✓ 25 / 500 Q 26 / 1 K © ® ✓ ✓�.7 ✓ 2713K FG ✓ ✓C- Q 2813K OW Q 29 / 4K ✓ ✓ Q ✓ p 30/5K Q Q Q ✓ Q �-� Q = "Hold Point" ( ) SANDBLAST INSPECTION n PRIME COATING Surface comparator Visual Surface finish Visual Mil profile Press-0 Tape Dry Film Thickness Gauge (3) INTERMEDIATE COATING O FINISH COATING Surface finish Visual Surface finish Visual Dry Film Thickness Gauge Dry Film Thickness Gauge Note: Holiday inspection of finish coat is not required for exterior surfaces CCC will inspect blast, mixing, environmentals, and DFrs two to three times per week until job completion. ALL INSPECTIONS MUST BE DOCUMENTED. CUSTOM COATING CONSULTANTS, LLC P.O. Box 23789 *Federal Way, WA 98093 (253) 929-1595 * Fax (253) 929-1596 * Mobile * (253) 381-9645 PROJECT INSPECTION REPORT PROJECT NAME: Unalakleet Bulk Fuel Upgrade PROJECT NO: 21747 PROJECT LOCATION: BMT Northwest REPORT NO: 1 . PAINTING CONTRACTOR: BMT Northwest PHONE NO: 360-352-7575 SPECIFYING AUTHORITY: PHONE NO: GENERAL CONTRACTOR: Hankal Construction PHONE NO: Type of Inspection: PRE -START / INTERIM / PRE -FINAL / FINAL / NONCOMPLIANT Portion of Project: Tanks #1 & #2 System(s) Inspected: SSPC-SP 10 Near White Blast Date of Inspection: June 14, 2006 Environmental Conditions: 1030: AT-71F; ST-64F; RH-51%; DP-52F Rain: X Cloudy: Clear: Fog: Instruments Used: Press-O-Film Replica Tape: X Course DFT Gauge Type 1: Type II: Adhesion Test: ASTM D 3359 Method A: pH Test: pH Pencil: Other Products: ICI Devoe Coatings Present: Gary Ficca & Dan Hayes — Custom Coating Consultants (CCC) Bob Barnhart — BMT Project Mgr. Jeff — BMT Painter Lonnie — BMT Shop Superintendent INSPECTOR'S NARRATIVE: A pre -construction meeting was held this morning onsite to establish inspection guidelines and scheduling. It was decided that CCC would coordinate with Bob Barnhart for scheduling inspections based on production schedules. Following the pre -construction meeting, we proceeded to the paint shop where we met Jeff and Lonnie. The bottom halves of tanks #1 & #2 and the top of tank #1 had been blasted clean this morning. A visual inspection for the cleanliness to meet the standard for SSPC — SP10 as specified. We did note some weld spatter that had not been removed as specified. This was pointed out to Jeff. One surface profile measurement was made on each piece with the following results: Tank # bottom 2.2 mils; Tank #1 top 2.1 mils; Tank #2 bottom 2.3 mils. The specifications call for 1.5 to 2.5 mils. The painter was preparing to apply the Devoe 302H Primer, which will be inspected tomorrow morning. The following photo shows the pieces inspected .this morning: Three pieces ready for priming. Unalakleet Bulk Fuel Upgrade Report #1 Page 2 of 2. Gary Ficca - Custom Coating Consultants, L.L.C. DATE: June 14, 2006 NACE Certified Coating Inspector #3366 CUSTOM COATING CONSULTANTS, LLC P.O. Bog 23789 * Federal Way, WA 98093 (253) 929-1595 * Fax (253) 929-1596 * Mobile * (253) 381-9645 PROJECT INSPECTION REPORT PROJECT NAME: Unalakleet Bulk Fuel Upgrade PROJECT NO: 21747 PROJECT LOCATION: BMT Northwest REPORT NO: 2 PAINTING CONTRACTOR: BMT Northwest PHONE NO: 360-352-7575 SPECIFYING AUTHORITY: PHONE NO: GENERAL CONTRACTOR: Hankal Construction PHONE NO: Type of Inspection: PRE -START / INTERIM / PRE -FINAL / FINAL / NONCOMPLIANT Portion of Project: Tanks #1 & #2 System(s) Inspected: Devoe 302H Zinc Primer Date of Inspection: June 15, 2006 Environmental Conditions: 0900: AT-61F; ST-59F; RH-76%; DP-53F Rain: Cloudy: X Clear: Fog: Instruments Used: Press-O-Film Replica Tape: DFT Gauge Type 1: Type II: X Adhesion Test: ASTM D 3359 Method A: pH Test: pH Pencil: Other Products: ICI Devoe Coatings Present: Gary Ficca — Custom Coating Consultants (CCC) Bob Barnhart — BMT Project Mgr. Jeff — BMT Painter INSPECTOR'S NARRATIVE: Upon arrival this morning, CCC found Tank #1 Top & Bottom as well as Tank #2 Bottom had all received the specified primer. A visual inspection found the application to appear uniform and void of any runs and sags. Random dry film thickness measurements were made using a properly calibrated Positector 6000, Dry Film Thickness Gauge. The average thickness was measured to be 4.2 mils. This meets the specified thickness of 3.0 to 4.0 mils DFT. The painters were preparing to apply the intermediate coat by stripe coating the sharp edges and welds. No discrepancies were noted during this inspection. The following photo shows the pieces inspected this morning: Three pieces primed with 302H. Unalakleet Bulk Fuel Upgrade Report #2 Page 2 of 2. Gary Ficca - Custom Coating Consultants, L.L.C. DATE: June 14, 2006 NACE Certified Coating Inspector #3366 Ue BROWN-- INNf=APOUs TANK MANUFACTURER'S CERTIFICATION FOR A TANK BUILT TO API STANDARD 650 To: Hankal Constmcdon AEA Unalaldee� AK. We hereby certify that the tanks constructed for the Unaiakleet Bulk Fuel Upgrade Project Number 2K6-100 and as described as follows:`°Tank Serial Numbers 21803--1, 81203-2, 81203-3, and 81203-4, 25'-2" diameter by 24'- 0" tall with a conical fixed roof meet all applicable requirements of API 650, Tenth Edition, Addendum 4, Appendix A, dated December 2005, including the requirements for design, and fabrication. Brown Minneapolis Tank, LLC Thomas R. Callea Quality Control Manager / CWI July 23, 2007 r YUnderwriter,*, Laboratories Inc. June 18, 2007 Mr. Russ Gibbs Brown Minneapolis Tank -- Northwest LLC 1218 West Bay Drive PO Box 9 Olympia, WA 98507 United States Reference: File MH6266 Project 07NK11797 Product Aboveground Tanks Installed in Unalakleet Alaska Korthbrook Division 333 Pfingsten Road Northbrook, IL 50062-21396 USA wuwv.ul.com tel:1 847 272 8800 fax: 1 847 272 8129 Custbmer service: 1877 854 3577 Dear Mr. Gibbs, Any information and documentation involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. (UL) or any authorized licensee of UL. UL's investigation 'of your product has been completed under the above project number and the subject product was determined to comply with the applicable requirements. At your request our focal Field Representative,13ill Dotter, has witnessed leakage testing on vertical aboveground tanks -manufactured at your facility and installed in Unalakleet, Alaska. He has confirmed that the vacuum box leakage test was conducted in accordance with the manufacturer's guidelines and reviewed the records for the 23 vertical aboveground tanks installed in Unalakleet, Alaska. Based on the results of this testing, we have confirmed. that these tanks are leak tight This completes our work under Project 07NK11797 Sincerely, Way~ _q""&e4y_e4/ Wayne Doversberger Staff Engineer Department: 3009ONBK Tel: 847 664-2072 Fax: 847 313-2072 Reviewed by: Tim Crews Staff' Engineer. Department: 3009DNBK An independent organization working for a safer world with inleority, precision and kIT0wIadge, i��,U_�A