HomeMy WebLinkAboutPCE FY13 Statistical Report Community 2013-PCEPOWER COST EQUALIZATION PROGRAM
Statistical Data by Community
Reporting Period: 07/01/12..06/30/13
Table of Contents
Adak…………………………………………………………………………...…………………………….……………………………………..7
Akiachak…………………………………………………………………………...…………………………….……………………………………..8
Akiak…………………………………………………………………………...…………………………….……………………………………..9
Akutan…………………………………………………………………………...…………………………….……………………………………..10
Alakanuk…………………………………………………………………………...…………………………….……………………………………..11
Allakaket; Alatna…………………………………………………………………………...…………………………….……………………………………..12
Ambler…………………………………………………………………………...…………………………….……………………………………..13
Anaktuvuk Pass…………………………………………………………………………...…………………………….……………………………………..14
Angoon…………………………………………………………………………...…………………………….……………………………………..15
Aniak…………………………………………………………………………...…………………………….……………………………………..16
Anvik…………………………………………………………………………...…………………………….……………………………………..17
Arctic Village…………………………………………………………………………...…………………………….……………………………………..18
Atka…………………………………………………………………………...…………………………….……………………………………..19
Atmautluak…………………………………………………………………………...…………………………….……………………………………..20
Atqasuk…………………………………………………………………………...…………………………….……………………………………..21
Beaver…………………………………………………………………………...…………………………….……………………………………..22
Bethel; Oscarville…………………………………………………………………………...…………………………….……………………………………..23
Bettles; Evansville…………………………………………………………………………...…………………………….……………………………………..24
Brevig Mission…………………………………………………………………………...…………………………….……………………………………..25
Buckland…………………………………………………………………………...…………………………….……………………………………..26
Central…………………………………………………………………………...…………………………….……………………………………..27
Chalkyitsik…………………………………………………………………………...…………………………….……………………………………..28
Chefornak…………………………………………………………………………...…………………………….……………………………………..29
Chenega Bay…………………………………………………………………………...…………………………….……………………………………..30
Chevak…………………………………………………………………………...…………………………….……………………………………..31
Chignik Lagoon…………………………………………………………………………...…………………………….……………………………………..32
Chignik Lake…………………………………………………………………………...…………………………….……………………………………..33
Chignik…………………………………………………………………………...…………………………….……………………………………..34
Chilkat Valley…………………………………………………………………………...…………………………….……………………………………..35
Chistochina…………………………………………………………………………...…………………………….……………………………………..36
Chitina…………………………………………………………………………...…………………………….……………………………………..37
Chuathbaluk…………………………………………………………………………...…………………………….……………………………………..38
Circle…………………………………………………………………………...…………………………….……………………………………..39
Coffman Cove…………………………………………………………………………...…………………………….……………………………………..40
Cold Bay…………………………………………………………………………...…………………………….……………………………………..41
Cordova…………………………………………………………………………...…………………………….……………………………………..42
Craig…………………………………………………………………………...…………………………….……………………………………..43
Crooked Creek…………………………………………………………………………...…………………………….……………………………………..44
Deering…………………………………………………………………………...…………………………….……………………………………..45
Page 2 of 181
POWER COST EQUALIZATION PROGRAM
Statistical Data by Community
Reporting Period: 07/01/12..06/30/13
Table of Contents
Dillingham; Aleknagik…………………………………………………………………………...…………………………….……………………………………..46
Diomede…………………………………………………………………………...…………………………….……………………………………..47
Dot Lake; Dot Lake Village…………………………………………………………………………...…………………………….……………………………………..48
Eagle; Eagle Village…………………………………………………………………………...…………………………….……………………………………..49
Eek…………………………………………………………………………...…………………………….……………………………………..50
Egegik…………………………………………………………………………...…………………………….……………………………………..51
Ekwok…………………………………………………………………………...…………………………….……………………………………..52
Elfin Cove…………………………………………………………………………...…………………………….……………………………………..53
Elim…………………………………………………………………………...…………………………….……………………………………..54
Emmonak…………………………………………………………………………...…………………………….……………………………………..55
False Pass…………………………………………………………………………...…………………………….……………………………………..56
Fort Yukon…………………………………………………………………………...…………………………….……………………………………..57
Galena…………………………………………………………………………...…………………………….……………………………………..58
Gambell…………………………………………………………………………...…………………………….……………………………………..59
Golovin…………………………………………………………………………...…………………………….……………………………………..60
Goodnews Bay…………………………………………………………………………...…………………………….……………………………………..61
Grayling…………………………………………………………………………...…………………………….……………………………………..62
Gustavus…………………………………………………………………………...…………………………….……………………………………..63
Haines; Covenant Life…………………………………………………………………………...…………………………….……………………………………..64
Healy Lake…………………………………………………………………………...…………………………….……………………………………..65
Hollis…………………………………………………………………………...…………………………….……………………………………..66
Holy Cross…………………………………………………………………………...…………………………….……………………………………..67
Hoonah…………………………………………………………………………...…………………………….……………………………………..68
Hooper Bay…………………………………………………………………………...…………………………….……………………………………..69
Hughes…………………………………………………………………………...…………………………….……………………………………..70
Huslia…………………………………………………………………………...…………………………….……………………………………..71
Hydaburg…………………………………………………………………………...…………………………….……………………………………..72
Igiugig…………………………………………………………………………...…………………………….……………………………………..73
Iliamna Newhalen Nondalton…………………………………………………………………………...…………………………….……………………………………..74
Kake…………………………………………………………………………...…………………………….……………………………………..75
Kaktovik…………………………………………………………………………...…………………………….……………………………………..76
Kaltag…………………………………………………………………………...…………………………….……………………………………..77
Karluk…………………………………………………………………………...…………………………….……………………………………..78
Kasigluk…………………………………………………………………………...…………………………….……………………………………..79
Kiana…………………………………………………………………………...…………………………….……………………………………..80
King Cove…………………………………………………………………………...…………………………….……………………………………..81
Kipnuk…………………………………………………………………………...…………………………….……………………………………..82
Kivalina…………………………………………………………………………...…………………………….……………………………………..83
Klawock…………………………………………………………………………...…………………………….……………………………………..84
Klukwan…………………………………………………………………………...…………………………….……………………………………..85
Kobuk…………………………………………………………………………...…………………………….……………………………………..86
Page 3 of 181
POWER COST EQUALIZATION PROGRAM
Statistical Data by Community
Reporting Period: 07/01/12..06/30/13
Table of Contents
Kokhanok…………………………………………………………………………...…………………………….……………………………………..87
Koliganek…………………………………………………………………………...…………………………….……………………………………..88
Kongiganak…………………………………………………………………………...…………………………….……………………………………..89
Kotlik…………………………………………………………………………...…………………………….……………………………………..90
Kotzebue…………………………………………………………………………...…………………………….……………………………………..91
Koyuk…………………………………………………………………………...…………………………….……………………………………..92
Koyukuk…………………………………………………………………………...…………………………….……………………………………..93
Kwethluk…………………………………………………………………………...…………………………….……………………………………..94
Kwigillingok…………………………………………………………………………...…………………………….……………………………………..95
Larsen Bay…………………………………………………………………………...…………………………….……………………………………..96
Levelock…………………………………………………………………………...…………………………….……………………………………..97
Lime Village…………………………………………………………………………...…………………………….……………………………………..98
Lower Kalskag…………………………………………………………………………...…………………………….……………………………………..99
Manley Hot Springs…………………………………………………………………………...…………………………….……………………………………..100
Manokotak…………………………………………………………………………...…………………………….……………………………………..101
Marshall…………………………………………………………………………...…………………………….……………………………………..102
McGrath…………………………………………………………………………...…………………………….……………………………………..103
Mekoryuk…………………………………………………………………………...…………………………….……………………………………..104
Mentasta…………………………………………………………………………...…………………………….……………………………………..105
Minto…………………………………………………………………………...…………………………….……………………………………..106
Mt. Village…………………………………………………………………………...…………………………….……………………………………..107
Naknek;S.Naknek;Kng Slmn…………………………………………………………………………...…………………………….……………………………………..108
Napakiak…………………………………………………………………………...…………………………….……………………………………..109
Napaskiak…………………………………………………………………………...…………………………….……………………………………..110
Naukati…………………………………………………………………………...…………………………….……………………………………..111
Nelson Lagoon…………………………………………………………………………...…………………………….……………………………………..112
New Stuyahok…………………………………………………………………………...…………………………….……………………………………..113
Newtok…………………………………………………………………………...…………………………….……………………………………..114
Nightmute…………………………………………………………………………...…………………………….……………………………………..115
Nikolai…………………………………………………………………………...…………………………….……………………………………..116
Nikolski…………………………………………………………………………...…………………………….……………………………………..117
Noatak…………………………………………………………………………...…………………………….……………………………………..118
Nome…………………………………………………………………………...…………………………….……………………………………..119
Noorvik…………………………………………………………………………...…………………………….……………………………………..120
Northway; Northway Village…………………………………………………………………………...…………………………….……………………………………..121
Nuiqsut…………………………………………………………………………...…………………………….……………………………………..122
Nulato…………………………………………………………………………...…………………………….……………………………………..123
Nunam Iqua…………………………………………………………………………...…………………………….……………………………………..124
Nunapitchuk…………………………………………………………………………...…………………………….……………………………………..125
Old Harbor…………………………………………………………………………...…………………………….……………………………………..126
Ouzinkie…………………………………………………………………………...…………………………….……………………………………..127
Page 4 of 181
POWER COST EQUALIZATION PROGRAM
Statistical Data by Community
Reporting Period: 07/01/12..06/30/13
Table of Contents
Pedro Bay…………………………………………………………………………...…………………………….……………………………………..128
Pelican…………………………………………………………………………...…………………………….……………………………………..129
Perryville…………………………………………………………………………...…………………………….……………………………………..130
Pilot Point…………………………………………………………………………...…………………………….……………………………………..131
Pilot Station…………………………………………………………………………...…………………………….……………………………………..132
Pitkas Point…………………………………………………………………………...…………………………….……………………………………..133
Point Hope…………………………………………………………………………...…………………………….……………………………………..134
Point Lay…………………………………………………………………………...…………………………….……………………………………..135
Port Alsworth…………………………………………………………………………...…………………………….……………………………………..136
Port Heiden…………………………………………………………………………...…………………………….……………………………………..137
Quinhagak…………………………………………………………………………...…………………………….……………………………………..138
Red Devil…………………………………………………………………………...…………………………….……………………………………..139
Ruby…………………………………………………………………………...…………………………….……………………………………..140
Russian Mission…………………………………………………………………………...…………………………….……………………………………..141
Sand Point…………………………………………………………………………...…………………………….……………………………………..142
Savoonga…………………………………………………………………………...…………………………….……………………………………..143
Scammon Bay…………………………………………………………………………...…………………………….……………………………………..144
Selawik…………………………………………………………………………...…………………………….……………………………………..145
Shageluk…………………………………………………………………………...…………………………….……………………………………..146
Shaktoolik…………………………………………………………………………...…………………………….……………………………………..147
Shishmaref…………………………………………………………………………...…………………………….……………………………………..148
Shungnak…………………………………………………………………………...…………………………….……………………………………..149
Skagway…………………………………………………………………………...…………………………….……………………………………..150
Slana…………………………………………………………………………...…………………………….……………………………………..151
Sleetmute…………………………………………………………………………...…………………………….……………………………………..152
St. George…………………………………………………………………………...…………………………….……………………………………..153
St. Mary's; Andreafsky…………………………………………………………………………...…………………………….……………………………………..154
St. Michael…………………………………………………………………………...…………………………….……………………………………..155
St. Paul…………………………………………………………………………...…………………………….……………………………………..156
Stebbins…………………………………………………………………………...…………………………….……………………………………..157
Stony River…………………………………………………………………………...…………………………….……………………………………..158
Takotna…………………………………………………………………………...…………………………….……………………………………..159
Tanana…………………………………………………………………………...…………………………….……………………………………..160
Tatitlek…………………………………………………………………………...…………………………….……………………………………..161
Teller…………………………………………………………………………...…………………………….……………………………………..162
Tenakee Springs…………………………………………………………………………...…………………………….……………………………………..163
Tetlin…………………………………………………………………………...…………………………….……………………………………..164
Thorne Bay; Kasaan…………………………………………………………………………...…………………………….……………………………………..165
Togiak…………………………………………………………………………...…………………………….……………………………………..166
Tok; Tanacross…………………………………………………………………………...…………………………….……………………………………..167
Toksook Bay…………………………………………………………………………...…………………………….……………………………………..168
Page 5 of 181
POWER COST EQUALIZATION PROGRAM
Statistical Data by Community
Reporting Period: 07/01/12..06/30/13
Table of Contents
Tuluksak…………………………………………………………………………...…………………………….……………………………………..169
Tuntutuliak…………………………………………………………………………...…………………………….……………………………………..170
Tununak…………………………………………………………………………...…………………………….……………………………………..171
Twin Hills…………………………………………………………………………...…………………………….……………………………………..172
Unalakleet…………………………………………………………………………...…………………………….……………………………………..173
Unalaska…………………………………………………………………………...…………………………….……………………………………..174
Upper Kalskag…………………………………………………………………………...…………………………….……………………………………..175
Venetie…………………………………………………………………………...…………………………….……………………………………..176
Wainwright…………………………………………………………………………...…………………………….……………………………………..177
Wales…………………………………………………………………………...…………………………….……………………………………..178
Whale Pass…………………………………………………………………………...…………………………….……………………………………..179
White Mountain…………………………………………………………………………...…………………………….……………………………………..180
Yakutat…………………………………………………………………………...…………………………….……………………………………..181
Page 6 of 181
Adak PCE
Utility: TDX ADAK GENERATING LLC
Reporting Period: 07/01/12..06/30/13
Community Population 331
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 131
Community Facility Customers 7
Other Customers (Non-PCE)108
Fiscal Year PCE Payments $330,916
PCE Statistical Data
PCE Eligible kWh - Residential Customers 300,474 Average Annual PCE Payment per Eligible
Customer
$2,398
PCE Eligible kWh - Community Facility
Customers
200,484 Average PCE Payment per Eligible kWh $0.66
Total PCE Eligible kWh 500,958 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.20
Average Monthly PCE Eligible kWh per
Residential Customer
191 Last Reported PCE Level (per kWh)$0.81
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,387 Effective Residential Rate (per kWh)$0.39
Average Monthly PCE Eligible Community
Facility kWh per person
50 PCE Eligible kWh vs Total kWh Sold 22.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 3,213,377 Fuel Used (Gallons)249,115
Non-Diesel kWh Generated 0 Fuel Cost $1,215,681
Purchased kWh 0 Average Price of Fuel $4.88
Total Purchased & Generated 3,213,377 Fuel Cost per kWh sold $0.56
Annual Non-Fuel Expenses $457,048
Non-Fuel Expense per kWh sold $0.21
Total Expense per kWh sold $0.77
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 417,072 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
68.0%
Community Facility kWh Sold 348,416 Line Loss (%)32.0%
Other kWh Sold (Non-PCE)1,418,566 Fuel Efficiency (kWh per gallon of diesel)12.90
Total kWh Sold 2,184,054 PH Consumption as % of generation 0.0%
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 2,184,054
Comments
Powerhouse use not reported Jul-Jun
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 7 of 181
Akiachak PCE
Utility: AKIACHAK NATIVE COMMUNITY
Reporting Period: 07/01/12..06/30/13
Community Population 655
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 163
Community Facility Customers 10
Other Customers (Non-PCE)47
Fiscal Year PCE Payments $251,852
PCE Statistical Data
PCE Eligible kWh - Residential Customers 571,881 Average Annual PCE Payment per Eligible
Customer
$1,456
PCE Eligible kWh - Community Facility
Customers
164,767 Average PCE Payment per Eligible kWh $0.34
Total PCE Eligible kWh 736,648 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.60
Average Monthly PCE Eligible kWh per
Residential Customer
292 Last Reported PCE Level (per kWh)$0.37
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,373 Effective Residential Rate (per kWh)$0.23
Average Monthly PCE Eligible Community
Facility kWh per person
21 PCE Eligible kWh vs Total kWh Sold 41.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,933,450 Fuel Used (Gallons)135,330
Non-Diesel kWh Generated 0 Fuel Cost $595,493
Purchased kWh 0 Average Price of Fuel $4.40
Total Purchased & Generated 1,933,450 Fuel Cost per kWh sold $0.34
Annual Non-Fuel Expenses $500,438
Non-Fuel Expense per kWh sold $0.28
Total Expense per kWh sold $0.62
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 661,139 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
91.2%
Community Facility kWh Sold 164,767 Line Loss (%)7.0%
Other kWh Sold (Non-PCE)936,780 Fuel Efficiency (kWh per gallon of diesel)14.29
Total kWh Sold 1,762,686 PH Consumption as % of generation 1.8%
Powerhouse (PH) Consumption kWh 34,658
Total kWh Sold & PH Consumption 1,797,344
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 8 of 181
Akiak PCE
Utility: AKIAK CITY COUNCIL
Reporting Period: 07/01/12..06/30/13
Community Population 367
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 97
Community Facility Customers 9
Other Customers (Non-PCE)20
Fiscal Year PCE Payments $128,602
PCE Statistical Data
PCE Eligible kWh - Residential Customers 292,430 Average Annual PCE Payment per Eligible
Customer
$1,213
PCE Eligible kWh - Community Facility
Customers
35,670 Average PCE Payment per Eligible kWh $0.39
Total PCE Eligible kWh 328,100 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.63
Average Monthly PCE Eligible kWh per
Residential Customer
251 Last Reported PCE Level (per kWh)$0.41
Average Monthly PCE Eligible kWh per
Community Facility Customer
330 Effective Residential Rate (per kWh)$0.22
Average Monthly PCE Eligible Community
Facility kWh per person
8 PCE Eligible kWh vs Total kWh Sold 33.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,188,049 Fuel Used (Gallons)70,203
Non-Diesel kWh Generated 0 Fuel Cost $357,700
Purchased kWh 0 Average Price of Fuel $5.10
Total Purchased & Generated 1,188,049 Fuel Cost per kWh sold $0.37
Annual Non-Fuel Expenses $183,762
Non-Fuel Expense per kWh sold $0.19
Total Expense per kWh sold $0.56
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 306,985 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
81.4%
Community Facility kWh Sold 171,726 Line Loss (%)16.2%
Other kWh Sold (Non-PCE)488,534 Fuel Efficiency (kWh per gallon of diesel)16.92
Total kWh Sold 967,245 PH Consumption as % of generation 2.4%
Powerhouse (PH) Consumption kWh 28,448
Total kWh Sold & PH Consumption 995,693
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 9 of 181
Akutan PCE
Utility: CITY OF AKUTAN
Reporting Period: 07/01/12..06/30/13
Community Population 1040
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 40
Community Facility Customers 11
Other Customers (Non-PCE)18
Fiscal Year PCE Payments $40,065
PCE Statistical Data
PCE Eligible kWh - Residential Customers 159,883 Average Annual PCE Payment per Eligible
Customer
$786
PCE Eligible kWh - Community Facility
Customers
62,701 Average PCE Payment per Eligible kWh $0.18
Total PCE Eligible kWh 222,584 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.32
Average Monthly PCE Eligible kWh per
Residential Customer
333 Last Reported PCE Level (per kWh)$0.18
Average Monthly PCE Eligible kWh per
Community Facility Customer
475 Effective Residential Rate (per kWh)$0.14
Average Monthly PCE Eligible Community
Facility kWh per person
5 PCE Eligible kWh vs Total kWh Sold 43.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 384,034 Fuel Used (Gallons)44,321
Non-Diesel kWh Generated 209,042 Fuel Cost $179,877
Purchased kWh 0 Average Price of Fuel $4.06
Total Purchased & Generated 593,076 Fuel Cost per kWh sold $0.35
Annual Non-Fuel Expenses $206,054
Non-Fuel Expense per kWh sold $0.41
Total Expense per kWh sold $0.76
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 191,685 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
85.7%
Community Facility kWh Sold 96,769 Line Loss (%)7.7%
Other kWh Sold (Non-PCE)219,587 Fuel Efficiency (kWh per gallon of diesel)8.66
Total kWh Sold 508,041 PH Consumption as % of generation 6.6%
Powerhouse (PH) Consumption kWh 39,173
Total kWh Sold & PH Consumption 547,214
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 10 of 181
Alakanuk PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 683
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 156
Community Facility Customers 9
Other Customers (Non-PCE)29
Fiscal Year PCE Payments $394,147
PCE Statistical Data
PCE Eligible kWh - Residential Customers 655,539 Average Annual PCE Payment per Eligible
Customer
$2,389
PCE Eligible kWh - Community Facility
Customers
329,733 Average PCE Payment per Eligible kWh $0.40
Total PCE Eligible kWh 985,272 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.62
Average Monthly PCE Eligible kWh per
Residential Customer
350 Last Reported PCE Level (per kWh)$0.42
Average Monthly PCE Eligible kWh per
Community Facility Customer
3,053 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per person
40 PCE Eligible kWh vs Total kWh Sold 47.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,222,913 Fuel Used (Gallons)164,989
Non-Diesel kWh Generated 0 Fuel Cost $631,893
Purchased kWh 0 Average Price of Fuel $3.83
Total Purchased & Generated 2,222,913 Fuel Cost per kWh sold $0.31
Annual Non-Fuel Expenses $566,547
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.58
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 789,488 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
92.9%
Community Facility kWh Sold 336,933 Line Loss (%)3.9%
Other kWh Sold (Non-PCE)939,714 Fuel Efficiency (kWh per gallon of diesel)13.47
Total kWh Sold 2,066,135 PH Consumption as % of generation 3.1%
Powerhouse (PH) Consumption kWh 69,507
Total kWh Sold & PH Consumption 2,135,642
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 11 of 181
Allakaket; Alatna PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/12..06/30/13
Community Population 140
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 69
Community Facility Customers 11
Other Customers (Non-PCE)23
Fiscal Year PCE Payments $163,119
PCE Statistical Data
PCE Eligible kWh - Residential Customers 212,108 Average Annual PCE Payment per Eligible
Customer
$2,039
PCE Eligible kWh - Community Facility
Customers
29,458 Average PCE Payment per Eligible kWh $0.68
Total PCE Eligible kWh 241,566 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.77
Average Monthly PCE Eligible kWh per
Residential Customer
256 Last Reported PCE Level (per kWh)$0.55
Average Monthly PCE Eligible kWh per
Community Facility Customer
223 Effective Residential Rate (per kWh)$0.22
Average Monthly PCE Eligible Community
Facility kWh per person
18 PCE Eligible kWh vs Total kWh Sold 38.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 705,288 Fuel Used (Gallons)57,239
Non-Diesel kWh Generated 0 Fuel Cost $347,555
Purchased kWh 0 Average Price of Fuel $6.07
Total Purchased & Generated 705,288 Fuel Cost per kWh sold $0.56
Annual Non-Fuel Expenses $108,286
Non-Fuel Expense per kWh sold $0.17
Total Expense per kWh sold $0.73
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 222,203 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
88.7%
Community Facility kWh Sold 60,057 Line Loss (%)7.0%
Other kWh Sold (Non-PCE)343,129 Fuel Efficiency (kWh per gallon of diesel)12.32
Total kWh Sold 625,389 PH Consumption as % of generation 4.3%
Powerhouse (PH) Consumption kWh 30,441
Total kWh Sold & PH Consumption 655,830
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 12 of 181
Ambler PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 276
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 81
Community Facility Customers 12
Other Customers (Non-PCE)18
Fiscal Year PCE Payments $221,305
PCE Statistical Data
PCE Eligible kWh - Residential Customers 306,079 Average Annual PCE Payment per Eligible
Customer
$2,380
PCE Eligible kWh - Community Facility
Customers
208,995 Average PCE Payment per Eligible kWh $0.43
Total PCE Eligible kWh 515,074 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.62
Average Monthly PCE Eligible kWh per
Residential Customer
315 Last Reported PCE Level (per kWh)$0.42
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,451 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per person
63 PCE Eligible kWh vs Total kWh Sold 41.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,318,829 Fuel Used (Gallons)94,692
Non-Diesel kWh Generated 0 Fuel Cost $397,743
Purchased kWh 0 Average Price of Fuel $4.20
Total Purchased & Generated 1,318,829 Fuel Cost per kWh sold $0.32
Annual Non-Fuel Expenses $340,464
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.59
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 456,785 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
94.1%
Community Facility kWh Sold 208,645 Line Loss (%)2.9%
Other kWh Sold (Non-PCE)576,205 Fuel Efficiency (kWh per gallon of diesel)13.93
Total kWh Sold 1,241,635 PH Consumption as % of generation 3.0%
Powerhouse (PH) Consumption kWh 39,044
Total kWh Sold & PH Consumption 1,280,679
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 13 of 181
Anaktuvuk Pass PCE
Utility: NORTH SLOPE BOROUGH
Reporting Period: 07/01/12..06/30/13
Community Population 325
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 96
Community Facility Customers 2
Other Customers (Non-PCE)65
Fiscal Year PCE Payments $5,669
PCE Statistical Data
PCE Eligible kWh - Residential Customers 210,535 Average Annual PCE Payment per Eligible
Customer
$58
PCE Eligible kWh - Community Facility
Customers
40,638 Average PCE Payment per Eligible kWh $0.02
Total PCE Eligible kWh 251,173 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.15
Average Monthly PCE Eligible kWh per
Residential Customer
183 Last Reported PCE Level (per kWh)$0.01
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,693 Effective Residential Rate (per kWh)$0.14
Average Monthly PCE Eligible Community
Facility kWh per person
10 PCE Eligible kWh vs Total kWh Sold 6.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 4,267,301 Fuel Used (Gallons)307,315
Non-Diesel kWh Generated 0 Fuel Cost $1,823,942
Purchased kWh 0 Average Price of Fuel $5.94
Total Purchased & Generated 4,267,301 Fuel Cost per kWh sold $0.48
Annual Non-Fuel Expenses $839,085
Non-Fuel Expense per kWh sold $0.22
Total Expense per kWh sold $0.70
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 685,604 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
88.7%
Community Facility kWh Sold 40,638 Line Loss (%)6.6%
Other kWh Sold (Non-PCE)3,059,369 Fuel Efficiency (kWh per gallon of diesel)13.89
Total kWh Sold 3,785,611 PH Consumption as % of generation 4.7%
Powerhouse (PH) Consumption kWh 201,222
Total kWh Sold & PH Consumption 3,986,833
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 14 of 181
Angoon PCE
Utility: INSIDE PASSAGE ELECTRIC
Reporting Period: 07/01/12..06/30/13
Community Population 466
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 199
Community Facility Customers 8
Other Customers (Non-PCE)32
Fiscal Year PCE Payments $380,598
PCE Statistical Data
PCE Eligible kWh - Residential Customers 675,988 Average Annual PCE Payment per Eligible
Customer
$1,839
PCE Eligible kWh - Community Facility
Customers
214,574 Average PCE Payment per Eligible kWh $0.43
Total PCE Eligible kWh 890,562 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.68
Average Monthly PCE Eligible kWh per
Residential Customer
283 Last Reported PCE Level (per kWh)$0.46
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,235 Effective Residential Rate (per kWh)$0.23
Average Monthly PCE Eligible Community
Facility kWh per person
38 PCE Eligible kWh vs Total kWh Sold 55.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,823,517 Fuel Used (Gallons)133,093
Non-Diesel kWh Generated 0 Fuel Cost $557,471
Purchased kWh 0 Average Price of Fuel $4.19
Total Purchased & Generated 1,823,517 Fuel Cost per kWh sold $0.35
Annual Non-Fuel Expenses $462,609
Non-Fuel Expense per kWh sold $0.29
Total Expense per kWh sold $0.64
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 889,850 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
87.8%
Community Facility kWh Sold 214,574 Line Loss (%)8.5%
Other kWh Sold (Non-PCE)495,814 Fuel Efficiency (kWh per gallon of diesel)13.70
Total kWh Sold 1,600,238 PH Consumption as % of generation 3.8%
Powerhouse (PH) Consumption kWh 68,944
Total kWh Sold & PH Consumption 1,669,182
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 15 of 181
Aniak PCE
Utility: ANIAK LIGHT & POWER
Reporting Period: 07/01/12..06/30/13
Community Population 539
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 178
Community Facility Customers 2
Other Customers (Non-PCE)33
Fiscal Year PCE Payments $378,899
PCE Statistical Data
PCE Eligible kWh - Residential Customers 747,476 Average Annual PCE Payment per Eligible
Customer
$2,105
PCE Eligible kWh - Community Facility
Customers
51,758 Average PCE Payment per Eligible kWh $0.47
Total PCE Eligible kWh 799,234 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.76
Average Monthly PCE Eligible kWh per
Residential Customer
350 Last Reported PCE Level (per kWh)$0.50
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,157 Effective Residential Rate (per kWh)$0.25
Average Monthly PCE Eligible Community
Facility kWh per person
8 PCE Eligible kWh vs Total kWh Sold 35.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,690,300 Fuel Used (Gallons)209,822
Non-Diesel kWh Generated 0 Fuel Cost $869,513
Purchased kWh 0 Average Price of Fuel $4.14
Total Purchased & Generated 2,690,300 Fuel Cost per kWh sold $0.39
Annual Non-Fuel Expenses $1,005,898
Non-Fuel Expense per kWh sold $0.45
Total Expense per kWh sold $0.83
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 986,033 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
83.5%
Community Facility kWh Sold 51,758 Line Loss (%)14.8%
Other kWh Sold (Non-PCE)1,209,791 Fuel Efficiency (kWh per gallon of diesel)12.82
Total kWh Sold 2,247,582 PH Consumption as % of generation 1.7%
Powerhouse (PH) Consumption kWh 44,578
Total kWh Sold & PH Consumption 2,292,160
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 16 of 181
Anvik PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 79
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 41
Community Facility Customers 8
Other Customers (Non-PCE)20
Fiscal Year PCE Payments $84,195
PCE Statistical Data
PCE Eligible kWh - Residential Customers 136,430 Average Annual PCE Payment per Eligible
Customer
$1,718
PCE Eligible kWh - Community Facility
Customers
60,944 Average PCE Payment per Eligible kWh $0.43
Total PCE Eligible kWh 197,374 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.65
Average Monthly PCE Eligible kWh per
Residential Customer
277 Last Reported PCE Level (per kWh)$0.45
Average Monthly PCE Eligible kWh per
Community Facility Customer
635 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per person
64 PCE Eligible kWh vs Total kWh Sold 48.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 442,769 Fuel Used (Gallons)34,658
Non-Diesel kWh Generated 0 Fuel Cost $129,814
Purchased kWh 0 Average Price of Fuel $3.75
Total Purchased & Generated 442,769 Fuel Cost per kWh sold $0.32
Annual Non-Fuel Expenses $111,224
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.59
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 154,639 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
91.6%
Community Facility kWh Sold 67,891 Line Loss (%)4.9%
Other kWh Sold (Non-PCE)183,090 Fuel Efficiency (kWh per gallon of diesel)12.78
Total kWh Sold 405,620 PH Consumption as % of generation 3.4%
Powerhouse (PH) Consumption kWh 15,239
Total kWh Sold & PH Consumption 420,859
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 17 of 181
Arctic Village PCE
Utility: ARCTIC VILLAGE COUNCIL
Reporting Period: 07/01/12..06/30/13
Community Population 167
Last Reported Month June
No. of Monthly Payments Made 3
Residential Customers 66
Community Facility Customers 4
Other Customers (Non-PCE)14
Fiscal Year PCE Payments $17,789
PCE Statistical Data
PCE Eligible kWh - Residential Customers 32,663 Average Annual PCE Payment per Eligible
Customer
$254
PCE Eligible kWh - Community Facility
Customers
3,648 Average PCE Payment per Eligible kWh $0.49
Total PCE Eligible kWh 36,311 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.90
Average Monthly PCE Eligible kWh per
Residential Customer
165 Last Reported PCE Level (per kWh)$0.49
Average Monthly PCE Eligible kWh per
Community Facility Customer
304 Effective Residential Rate (per kWh)$0.41
Average Monthly PCE Eligible Community
Facility kWh per person
7 PCE Eligible kWh vs Total kWh Sold 39.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 129,540 Fuel Used (Gallons)10,460
Non-Diesel kWh Generated 0 Fuel Cost $71,745
Purchased kWh 0 Average Price of Fuel $6.86
Total Purchased & Generated 129,540 Fuel Cost per kWh sold $0.78
Annual Non-Fuel Expenses $6,406
Non-Fuel Expense per kWh sold $0.07
Total Expense per kWh sold $0.85
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 33,570 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
71.4%
Community Facility kWh Sold 10,312 Line Loss (%)24.7%
Other kWh Sold (Non-PCE)48,557 Fuel Efficiency (kWh per gallon of diesel)12.38
Total kWh Sold 92,439 PH Consumption as % of generation 3.9%
Powerhouse (PH) Consumption kWh 5,066
Total kWh Sold & PH Consumption 97,505
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 18 of 181
Atka PCE
Utility: CITY OF ATKA
Reporting Period: 07/01/12..06/30/13
Community Population 58
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 30
Community Facility Customers 16
Other Customers (Non-PCE)12
Fiscal Year PCE Payments $90,523
PCE Statistical Data
PCE Eligible kWh - Residential Customers 129,275 Average Annual PCE Payment per Eligible
Customer
$1,968
PCE Eligible kWh - Community Facility
Customers
28,297 Average PCE Payment per Eligible kWh $0.57
Total PCE Eligible kWh 157,572 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.74
Average Monthly PCE Eligible kWh per
Residential Customer
359 Last Reported PCE Level (per kWh)$0.58
Average Monthly PCE Eligible kWh per
Community Facility Customer
147 Effective Residential Rate (per kWh)$0.16
Average Monthly PCE Eligible Community
Facility kWh per person
41 PCE Eligible kWh vs Total kWh Sold 39.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 260,143 Fuel Used (Gallons)28,299
Non-Diesel kWh Generated 237,954 Fuel Cost $147,451
Purchased kWh 0 Average Price of Fuel $5.21
Total Purchased & Generated 498,097 Fuel Cost per kWh sold $0.37
Annual Non-Fuel Expenses $29,100
Non-Fuel Expense per kWh sold $0.07
Total Expense per kWh sold $0.44
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 163,128 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
80.5%
Community Facility kWh Sold 45,309 Line Loss (%)11.0%
Other kWh Sold (Non-PCE)192,403 Fuel Efficiency (kWh per gallon of diesel)9.19
Total kWh Sold 400,840 PH Consumption as % of generation 8.5%
Powerhouse (PH) Consumption kWh 42,558
Total kWh Sold & PH Consumption 443,398
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 19 of 181
Atmautluak PCE
Utility: ATMAUTLUAK TRIBAL UTILITIES
Reporting Period: 07/01/12..06/30/13
Community Population 275
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 72
Community Facility Customers 5
Other Customers (Non-PCE)15
Fiscal Year PCE Payments $104,850
PCE Statistical Data
PCE Eligible kWh - Residential Customers 267,857 Average Annual PCE Payment per Eligible
Customer
$1,362
PCE Eligible kWh - Community Facility
Customers
15,263 Average PCE Payment per Eligible kWh $0.37
Total PCE Eligible kWh 283,120 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.80
Average Monthly PCE Eligible kWh per
Residential Customer
310 Last Reported PCE Level (per kWh)$0.35
Average Monthly PCE Eligible kWh per
Community Facility Customer
254 Effective Residential Rate (per kWh)$0.44
Average Monthly PCE Eligible Community
Facility kWh per person
5 PCE Eligible kWh vs Total kWh Sold 42.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 808,342 Fuel Used (Gallons)55,908
Non-Diesel kWh Generated 0 Fuel Cost $256,870
Purchased kWh 0 Average Price of Fuel $4.59
Total Purchased & Generated 808,342 Fuel Cost per kWh sold $0.38
Annual Non-Fuel Expenses $99,314
Non-Fuel Expense per kWh sold $0.15
Total Expense per kWh sold $0.53
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 294,083 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
83.0%
Community Facility kWh Sold 54,543 Line Loss (%)14.5%
Other kWh Sold (Non-PCE)322,492 Fuel Efficiency (kWh per gallon of diesel)14.46
Total kWh Sold 671,118 PH Consumption as % of generation 2.4%
Powerhouse (PH) Consumption kWh 19,663
Total kWh Sold & PH Consumption 690,781
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 20 of 181
Atqasuk PCE
Utility: NORTH SLOPE BOROUGH
Reporting Period: 07/01/12..06/30/13
Community Population 244
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 63
Community Facility Customers 2
Other Customers (Non-PCE)52
Fiscal Year PCE Payments $8,991
PCE Statistical Data
PCE Eligible kWh - Residential Customers 142,571 Average Annual PCE Payment per Eligible
Customer
$138
PCE Eligible kWh - Community Facility
Customers
65,743 Average PCE Payment per Eligible kWh $0.04
Total PCE Eligible kWh 208,314 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.15
Average Monthly PCE Eligible kWh per
Residential Customer
189 Last Reported PCE Level (per kWh)$0.01
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,739 Effective Residential Rate (per kWh)$0.14
Average Monthly PCE Eligible Community
Facility kWh per person
22 PCE Eligible kWh vs Total kWh Sold 6.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 3,450,720 Fuel Used (Gallons)267,198
Non-Diesel kWh Generated 0 Fuel Cost $1,159,589
Purchased kWh 0 Average Price of Fuel $4.34
Total Purchased & Generated 3,450,720 Fuel Cost per kWh sold $0.35
Annual Non-Fuel Expenses $810,852
Non-Fuel Expense per kWh sold $0.25
Total Expense per kWh sold $0.60
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 655,680 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
95.2%
Community Facility kWh Sold 65,743 Line Loss (%)2.4%
Other kWh Sold (Non-PCE)2,565,105 Fuel Efficiency (kWh per gallon of diesel)12.91
Total kWh Sold 3,286,528 PH Consumption as % of generation 2.3%
Powerhouse (PH) Consumption kWh 80,928
Total kWh Sold & PH Consumption 3,367,456
Comments
Jul,Sep reported generation < sales
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 21 of 181
Beaver PCE
Utility: BEAVER JOINT UTILITIES
Reporting Period: 07/01/12..06/30/13
Community Population 77
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 32
Community Facility Customers 6
Other Customers (Non-PCE)10
Fiscal Year PCE Payments $44,251
PCE Statistical Data
PCE Eligible kWh - Residential Customers 75,862 Average Annual PCE Payment per Eligible
Customer
$1,164
PCE Eligible kWh - Community Facility
Customers
0 Average PCE Payment per Eligible kWh $0.58
Total PCE Eligible kWh 75,862 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.90
Average Monthly PCE Eligible kWh per
Residential Customer
198 Last Reported PCE Level (per kWh)$0.58
Average Monthly PCE Eligible kWh per
Community Facility Customer
0 Effective Residential Rate (per kWh)$0.32
Average Monthly PCE Eligible Community
Facility kWh per person
0 PCE Eligible kWh vs Total kWh Sold 26.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 311,171 Fuel Used (Gallons)26,666
Non-Diesel kWh Generated 0 Fuel Cost $135,428
Purchased kWh 0 Average Price of Fuel $5.08
Total Purchased & Generated 311,171 Fuel Cost per kWh sold $0.46
Annual Non-Fuel Expenses $51,306
Non-Fuel Expense per kWh sold $0.18
Total Expense per kWh sold $0.64
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 107,513 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
93.9%
Community Facility kWh Sold 73,185 Line Loss (%)6.1%
Other kWh Sold (Non-PCE)111,522 Fuel Efficiency (kWh per gallon of diesel)11.67
Total kWh Sold 292,220 PH Consumption as % of generation 0.0%
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 292,220
Comments
Pwrrhouse use not rptd; Only 11 months non-fuel rptd; Oct,Feb generation < sales
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 22 of 181
Bethel; Oscarville PCE
Utility: BETHEL UTILITIES CORPORATION
Reporting Period: 07/01/12..06/30/13
Community Population 6299
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 1,743
Community Facility Customers 16
Other Customers (Non-PCE)1,010
Fiscal Year PCE Payments $3,554,934
PCE Statistical Data
PCE Eligible kWh - Residential Customers 7,953,972 Average Annual PCE Payment per Eligible
Customer
$2,021
PCE Eligible kWh - Community Facility
Customers
735,422 Average PCE Payment per Eligible kWh $0.41
Total PCE Eligible kWh 8,689,394 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.60
Average Monthly PCE Eligible kWh per
Residential Customer
380 Last Reported PCE Level (per kWh)$0.43
Average Monthly PCE Eligible kWh per
Community Facility Customer
3,830 Effective Residential Rate (per kWh)$0.17
Average Monthly PCE Eligible Community
Facility kWh per person
10 PCE Eligible kWh vs Total kWh Sold 21.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 44,326,400 Fuel Used (Gallons)3,197,401
Non-Diesel kWh Generated 0 Fuel Cost $19,194,410
Purchased kWh 0 Average Price of Fuel $6.00
Total Purchased & Generated 44,326,400 Fuel Cost per kWh sold $0.47
Annual Non-Fuel Expenses $4,411,044
Non-Fuel Expense per kWh sold $0.11
Total Expense per kWh sold $0.57
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 10,258,912 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
93.1%
Community Facility kWh Sold 735,422 Line Loss (%)5.5%
Other kWh Sold (Non-PCE)30,252,426 Fuel Efficiency (kWh per gallon of diesel)13.86
Total kWh Sold 41,246,760 PH Consumption as % of generation 1.5%
Powerhouse (PH) Consumption kWh 647,200
Total kWh Sold & PH Consumption 41,893,960
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 23 of 181
Bettles; Evansville PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/12..06/30/13
Community Population 22
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 34
Community Facility Customers 5
Other Customers (Non-PCE)27
Fiscal Year PCE Payments $62,566
PCE Statistical Data
PCE Eligible kWh - Residential Customers 104,722 Average Annual PCE Payment per Eligible
Customer
$1,604
PCE Eligible kWh - Community Facility
Customers
18,480 Average PCE Payment per Eligible kWh $0.51
Total PCE Eligible kWh 123,202 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.67
Average Monthly PCE Eligible kWh per
Residential Customer
257 Last Reported PCE Level (per kWh)$0.46
Average Monthly PCE Eligible kWh per
Community Facility Customer
308 Effective Residential Rate (per kWh)$0.21
Average Monthly PCE Eligible Community
Facility kWh per person
70 PCE Eligible kWh vs Total kWh Sold 22.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 597,200 Fuel Used (Gallons)45,905
Non-Diesel kWh Generated 0 Fuel Cost $202,509
Purchased kWh 0 Average Price of Fuel $4.41
Total Purchased & Generated 597,200 Fuel Cost per kWh sold $0.37
Annual Non-Fuel Expenses $164,144
Non-Fuel Expense per kWh sold $0.30
Total Expense per kWh sold $0.67
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 132,934 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
91.8%
Community Facility kWh Sold 35,015 Line Loss (%)7.9%
Other kWh Sold (Non-PCE)380,557 Fuel Efficiency (kWh per gallon of diesel)13.01
Total kWh Sold 548,506 PH Consumption as % of generation 0.3%
Powerhouse (PH) Consumption kWh 1,803
Total kWh Sold & PH Consumption 550,309
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 24 of 181
Brevig Mission PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 414
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 92
Community Facility Customers 10
Other Customers (Non-PCE)17
Fiscal Year PCE Payments $199,646
PCE Statistical Data
PCE Eligible kWh - Residential Customers 367,279 Average Annual PCE Payment per Eligible
Customer
$1,957
PCE Eligible kWh - Community Facility
Customers
210,094 Average PCE Payment per Eligible kWh $0.35
Total PCE Eligible kWh 577,373 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.58
Average Monthly PCE Eligible kWh per
Residential Customer
333 Last Reported PCE Level (per kWh)$0.39
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,751 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
42 PCE Eligible kWh vs Total kWh Sold 53.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,144,141 Fuel Used (Gallons)81,444
Non-Diesel kWh Generated 0 Fuel Cost $287,098
Purchased kWh 0 Average Price of Fuel $3.53
Total Purchased & Generated 1,144,141 Fuel Cost per kWh sold $0.27
Annual Non-Fuel Expenses $293,783
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.54
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 499,974 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
93.6%
Community Facility kWh Sold 210,094 Line Loss (%)2.4%
Other kWh Sold (Non-PCE)361,327 Fuel Efficiency (kWh per gallon of diesel)14.05
Total kWh Sold 1,071,395 PH Consumption as % of generation 4.0%
Powerhouse (PH) Consumption kWh 45,567
Total kWh Sold & PH Consumption 1,116,962
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 25 of 181
Buckland PCE
Utility: CITY OF BUCKLAND C/O
Reporting Period: 07/01/12..06/30/13
Community Population 437
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 98
Community Facility Customers 10
Other Customers (Non-PCE)19
Fiscal Year PCE Payments $112,505
PCE Statistical Data
PCE Eligible kWh - Residential Customers 406,456 Average Annual PCE Payment per Eligible
Customer
$1,042
PCE Eligible kWh - Community Facility
Customers
38,479 Average PCE Payment per Eligible kWh $0.25
Total PCE Eligible kWh 444,935 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.47
Average Monthly PCE Eligible kWh per
Residential Customer
346 Last Reported PCE Level (per kWh)$0.25
Average Monthly PCE Eligible kWh per
Community Facility Customer
321 Effective Residential Rate (per kWh)$0.22
Average Monthly PCE Eligible Community
Facility kWh per person
7 PCE Eligible kWh vs Total kWh Sold 28.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,709,342 Fuel Used (Gallons)145,460
Non-Diesel kWh Generated 0 Fuel Cost $609,466
Purchased kWh 0 Average Price of Fuel $4.19
Total Purchased & Generated 1,709,342 Fuel Cost per kWh sold $0.39
Annual Non-Fuel Expenses $141,993
Non-Fuel Expense per kWh sold $0.09
Total Expense per kWh sold $0.48
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 662,819 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
91.2%
Community Facility kWh Sold 78,258 Line Loss (%)6.4%
Other kWh Sold (Non-PCE)817,696 Fuel Efficiency (kWh per gallon of diesel)11.75
Total kWh Sold 1,558,773 PH Consumption as % of generation 2.4%
Powerhouse (PH) Consumption kWh 40,893
Total kWh Sold & PH Consumption 1,599,666
Comments
May,Oct reported gen < sales
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 26 of 181
Central PCE
Utility: GOLD COUNTRY ENERGY
Reporting Period: 07/01/12..06/30/13
Community Population 92
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 139
Community Facility Customers 1
Other Customers (Non-PCE)13
Fiscal Year PCE Payments $125,093
PCE Statistical Data
PCE Eligible kWh - Residential Customers 259,127 Average Annual PCE Payment per Eligible
Customer
$894
PCE Eligible kWh - Community Facility
Customers
5,395 Average PCE Payment per Eligible kWh $0.47
Total PCE Eligible kWh 264,522 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.71
Average Monthly PCE Eligible kWh per
Residential Customer
155 Last Reported PCE Level (per kWh)$0.45
Average Monthly PCE Eligible kWh per
Community Facility Customer
450 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per person
5 PCE Eligible kWh vs Total kWh Sold 59.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 541,057 Fuel Used (Gallons)46,790
Non-Diesel kWh Generated 0 Fuel Cost $162,577
Purchased kWh 0 Average Price of Fuel $3.47
Total Purchased & Generated 541,057 Fuel Cost per kWh sold $0.37
Annual Non-Fuel Expenses $55,450
Non-Fuel Expense per kWh sold $0.12
Total Expense per kWh sold $0.49
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 269,640 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
82.3%
Community Facility kWh Sold 5,395 Line Loss (%)15.2%
Other kWh Sold (Non-PCE)170,173 Fuel Efficiency (kWh per gallon of diesel)11.56
Total kWh Sold 445,208 PH Consumption as % of generation 2.5%
Powerhouse (PH) Consumption kWh 13,599
Total kWh Sold & PH Consumption 458,807
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 27 of 181
Chalkyitsik PCE
Utility: CHALKYITSIK VILLAGE COUNCIL
Reporting Period: 07/01/12..06/30/13
Community Population 75
Last Reported Month June
No. of Monthly Payments Made 11
Residential Customers 44
Community Facility Customers 2
Other Customers (Non-PCE)20
Fiscal Year PCE Payments $28,524
PCE Statistical Data
PCE Eligible kWh - Residential Customers 50,013 Average Annual PCE Payment per Eligible
Customer
$620
PCE Eligible kWh - Community Facility
Customers
0 Average PCE Payment per Eligible kWh $0.57
Total PCE Eligible kWh 50,013 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.95
Average Monthly PCE Eligible kWh per
Residential Customer
103 Last Reported PCE Level (per kWh)$0.56
Average Monthly PCE Eligible kWh per
Community Facility Customer
0 Effective Residential Rate (per kWh)$0.39
Average Monthly PCE Eligible Community
Facility kWh per person
0 PCE Eligible kWh vs Total kWh Sold 21.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 292,760 Fuel Used (Gallons)27,279
Non-Diesel kWh Generated 0 Fuel Cost $159,584
Purchased kWh 0 Average Price of Fuel $5.85
Total Purchased & Generated 292,760 Fuel Cost per kWh sold $0.68
Annual Non-Fuel Expenses $43,366
Non-Fuel Expense per kWh sold $0.19
Total Expense per kWh sold $0.87
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 51,558 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
79.6%
Community Facility kWh Sold 16,444 Line Loss (%)15.6%
Other kWh Sold (Non-PCE)165,162 Fuel Efficiency (kWh per gallon of diesel)10.73
Total kWh Sold 233,164 PH Consumption as % of generation 4.7%
Powerhouse (PH) Consumption kWh 13,885
Total kWh Sold & PH Consumption 247,049
Comments
Only 11 months reported; May 2013 not submitted
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 28 of 181
Chefornak PCE
Utility: NATERKAQ LIGHT PLANT
Reporting Period: 07/01/12..06/30/13
Community Population 437
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 101
Community Facility Customers 7
Other Customers (Non-PCE)43
Fiscal Year PCE Payments $186,274
PCE Statistical Data
PCE Eligible kWh - Residential Customers 379,767 Average Annual PCE Payment per Eligible
Customer
$1,725
PCE Eligible kWh - Community Facility
Customers
89,395 Average PCE Payment per Eligible kWh $0.40
Total PCE Eligible kWh 469,162 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.90
Average Monthly PCE Eligible kWh per
Residential Customer
313 Last Reported PCE Level (per kWh)$0.52
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,064 Effective Residential Rate (per kWh)$0.38
Average Monthly PCE Eligible Community
Facility kWh per person
17 PCE Eligible kWh vs Total kWh Sold 45.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,812,860 Fuel Used (Gallons)132,248
Non-Diesel kWh Generated 0 Fuel Cost $688,931
Purchased kWh 0 Average Price of Fuel $5.21
Total Purchased & Generated 1,812,860 Fuel Cost per kWh sold $0.67
Annual Non-Fuel Expenses $246,273
Non-Fuel Expense per kWh sold $0.24
Total Expense per kWh sold $0.91
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 428,102 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
56.6%
Community Facility kWh Sold 89,473 Line Loss (%)40.8%
Other kWh Sold (Non-PCE)508,482 Fuel Efficiency (kWh per gallon of diesel)13.71
Total kWh Sold 1,026,057 PH Consumption as % of generation 2.6%
Powerhouse (PH) Consumption kWh 46,289
Total kWh Sold & PH Consumption 1,072,346
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 29 of 181
Chenega Bay PCE
Utility: CHENEGA IRA COUNCIL
Reporting Period: 07/01/12..06/30/13
Community Population 83
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 25
Community Facility Customers 6
Other Customers (Non-PCE)14
Fiscal Year PCE Payments $52,865
PCE Statistical Data
PCE Eligible kWh - Residential Customers 90,417 Average Annual PCE Payment per Eligible
Customer
$1,705
PCE Eligible kWh - Community Facility
Customers
21,134 Average PCE Payment per Eligible kWh $0.47
Total PCE Eligible kWh 111,551 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.67
Average Monthly PCE Eligible kWh per
Residential Customer
301 Last Reported PCE Level (per kWh)$0.49
Average Monthly PCE Eligible kWh per
Community Facility Customer
294 Effective Residential Rate (per kWh)$0.17
Average Monthly PCE Eligible Community
Facility kWh per person
21 PCE Eligible kWh vs Total kWh Sold 43.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 287,068 Fuel Used (Gallons)24,312
Non-Diesel kWh Generated 0 Fuel Cost $127,046
Purchased kWh 0 Average Price of Fuel $5.23
Total Purchased & Generated 287,068 Fuel Cost per kWh sold $0.50
Annual Non-Fuel Expenses $29,279
Non-Fuel Expense per kWh sold $0.11
Total Expense per kWh sold $0.61
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 106,673 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
88.9%
Community Facility kWh Sold 39,622 Line Loss (%)7.4%
Other kWh Sold (Non-PCE)108,948 Fuel Efficiency (kWh per gallon of diesel)11.81
Total kWh Sold 255,243 PH Consumption as % of generation 3.7%
Powerhouse (PH) Consumption kWh 10,669
Total kWh Sold & PH Consumption 265,912
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 30 of 181
Chevak PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 966
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 212
Community Facility Customers 11
Other Customers (Non-PCE)28
Fiscal Year PCE Payments $369,382
PCE Statistical Data
PCE Eligible kWh - Residential Customers 790,430 Average Annual PCE Payment per Eligible
Customer
$1,656
PCE Eligible kWh - Community Facility
Customers
406,647 Average PCE Payment per Eligible kWh $0.31
Total PCE Eligible kWh 1,197,077 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.53
Average Monthly PCE Eligible kWh per
Residential Customer
311 Last Reported PCE Level (per kWh)$0.34
Average Monthly PCE Eligible kWh per
Community Facility Customer
3,081 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
35 PCE Eligible kWh vs Total kWh Sold 48.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,709,307 Fuel Used (Gallons)136,808
Non-Diesel kWh Generated 908,019 Fuel Cost $506,901
Purchased kWh 0 Average Price of Fuel $3.71
Total Purchased & Generated 2,617,326 Fuel Cost per kWh sold $0.21
Annual Non-Fuel Expenses $672,280
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.48
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,043,413 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
93.7%
Community Facility kWh Sold 406,647 Line Loss (%)3.3%
Other kWh Sold (Non-PCE)1,001,670 Fuel Efficiency (kWh per gallon of diesel)12.49
Total kWh Sold 2,451,730 PH Consumption as % of generation 3.0%
Powerhouse (PH) Consumption kWh 79,386
Total kWh Sold & PH Consumption 2,531,116
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 31 of 181
Chignik Lagoon PCE
Utility: CHIGNIK LAGOON POWER UTILITY
Reporting Period: 07/01/12..06/30/13
Community Population 77
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 56
Community Facility Customers 6
Other Customers (Non-PCE)10
Fiscal Year PCE Payments $68,946
PCE Statistical Data
PCE Eligible kWh - Residential Customers 136,304 Average Annual PCE Payment per Eligible
Customer
$1,112
PCE Eligible kWh - Community Facility
Customers
39,861 Average PCE Payment per Eligible kWh $0.39
Total PCE Eligible kWh 176,165 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.75
Average Monthly PCE Eligible kWh per
Residential Customer
203 Last Reported PCE Level (per kWh)$0.39
Average Monthly PCE Eligible kWh per
Community Facility Customer
554 Effective Residential Rate (per kWh)$0.36
Average Monthly PCE Eligible Community
Facility kWh per person
43 PCE Eligible kWh vs Total kWh Sold 39.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 360,134 Fuel Used (Gallons)36,641
Non-Diesel kWh Generated 0 Fuel Cost $172,542
Purchased kWh 0 Average Price of Fuel $4.71
Total Purchased & Generated 360,134 Fuel Cost per kWh sold $0.39
Annual Non-Fuel Expenses $0
Non-Fuel Expense per kWh sold See Comments
Total Expense per kWh sold $0.39
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 224,765 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 48,504 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)167,711 Fuel Efficiency (kWh per gallon of diesel)9.83
Total kWh Sold 440,980 PH Consumption as % of generation 3.4%
Powerhouse (PH) Consumption kWh 12,099
Total kWh Sold & PH Consumption 453,079
Comments
Annual reported generation < consumed; Non-fuel $ not reported
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 32 of 181
Chignik Lake PCE
Utility: CHIGNIK LAKE ELECTRIC UTILITY
Reporting Period: 07/01/12..06/30/13
Community Population 69
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 41
Community Facility Customers 10
Other Customers (Non-PCE)5
Fiscal Year PCE Payments $77,958
PCE Statistical Data
PCE Eligible kWh - Residential Customers 122,918 Average Annual PCE Payment per Eligible
Customer
$1,529
PCE Eligible kWh - Community Facility
Customers
12,017 Average PCE Payment per Eligible kWh $0.58
Total PCE Eligible kWh 134,935 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.86
Average Monthly PCE Eligible kWh per
Residential Customer
250 Last Reported PCE Level (per kWh)$0.57
Average Monthly PCE Eligible kWh per
Community Facility Customer
100 Effective Residential Rate (per kWh)$0.29
Average Monthly PCE Eligible Community
Facility kWh per person
15 PCE Eligible kWh vs Total kWh Sold 38.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 378,663 Fuel Used (Gallons)37,364
Non-Diesel kWh Generated 0 Fuel Cost $190,441
Purchased kWh 0 Average Price of Fuel $5.10
Total Purchased & Generated 378,663 Fuel Cost per kWh sold $0.54
Annual Non-Fuel Expenses $61,504
Non-Fuel Expense per kWh sold $0.18
Total Expense per kWh sold $0.72
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 136,935 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
92.4%
Community Facility kWh Sold 43,957 Line Loss (%)4.0%
Other kWh Sold (Non-PCE)168,981 Fuel Efficiency (kWh per gallon of diesel)10.13
Total kWh Sold 349,873 PH Consumption as % of generation 3.6%
Powerhouse (PH) Consumption kWh 13,577
Total kWh Sold & PH Consumption 363,450
Comments
Dec,Jun reptd generation < sales
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 33 of 181
Chignik PCE
Utility: CITY OF CHIGNIK
Reporting Period: 07/01/12..06/30/13
Community Population 102
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 61
Community Facility Customers 10
Other Customers (Non-PCE)29
Fiscal Year PCE Payments $82,629
PCE Statistical Data
PCE Eligible kWh - Residential Customers 162,404 Average Annual PCE Payment per Eligible
Customer
$1,164
PCE Eligible kWh - Community Facility
Customers
78,697 Average PCE Payment per Eligible kWh $0.34
Total PCE Eligible kWh 241,101 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.55
Average Monthly PCE Eligible kWh per
Residential Customer
222 Last Reported PCE Level (per kWh)$0.34
Average Monthly PCE Eligible kWh per
Community Facility Customer
656 Effective Residential Rate (per kWh)$0.21
Average Monthly PCE Eligible Community
Facility kWh per person
64 PCE Eligible kWh vs Total kWh Sold 29.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 937,888 Fuel Used (Gallons)70,512
Non-Diesel kWh Generated 0 Fuel Cost $276,930
Purchased kWh 0 Average Price of Fuel $3.93
Total Purchased & Generated 937,888 Fuel Cost per kWh sold $0.34
Annual Non-Fuel Expenses $123,043
Non-Fuel Expense per kWh sold $0.15
Total Expense per kWh sold $0.48
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 203,097 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
88.0%
Community Facility kWh Sold 85,789 Line Loss (%)9.2%
Other kWh Sold (Non-PCE)536,868 Fuel Efficiency (kWh per gallon of diesel)13.30
Total kWh Sold 825,754 PH Consumption as % of generation 2.7%
Powerhouse (PH) Consumption kWh 25,495
Total kWh Sold & PH Consumption 851,249
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 34 of 181
Chilkat Valley PCE
Utility: INSIDE PASSAGE ELECTRIC
Reporting Period: 07/01/12..06/30/13
Community Population 609
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 206
Community Facility Customers 1
Other Customers (Non-PCE)41
Fiscal Year PCE Payments $233,374
PCE Statistical Data
PCE Eligible kWh - Residential Customers 544,126 Average Annual PCE Payment per Eligible
Customer
$1,127
PCE Eligible kWh - Community Facility
Customers
789 Average PCE Payment per Eligible kWh $0.43
Total PCE Eligible kWh 544,915 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.68
Average Monthly PCE Eligible kWh per
Residential Customer
220 Last Reported PCE Level (per kWh)$0.46
Average Monthly PCE Eligible kWh per
Community Facility Customer
66 Effective Residential Rate (per kWh)$0.23
Average Monthly PCE Eligible Community
Facility kWh per person
0 PCE Eligible kWh vs Total kWh Sold 49.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 957,102 Fuel Cost $0
Purchased kWh 778,500 Average Price of Fuel $0.00
Total Purchased & Generated 1,735,602 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $483,869
Non-Fuel Expense per kWh sold $0.44
Total Expense per kWh sold $0.44
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 664,053 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
63.4%
Community Facility kWh Sold 789 Line Loss (%)33.1%
Other kWh Sold (Non-PCE)435,178 Fuel Efficiency (kWh per gallon of diesel)N/A
Total kWh Sold 1,100,020 PH Consumption as % of generation 3.5%
Powerhouse (PH) Consumption kWh 60,440
Total kWh Sold & PH Consumption 1,160,460
Comments
Provides power to Klukwan; purchases power from AP&T
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 35 of 181
Chistochina PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/12..06/30/13
Community Population 104
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 49
Community Facility Customers 2
Other Customers (Non-PCE)16
Fiscal Year PCE Payments $90,762
PCE Statistical Data
PCE Eligible kWh - Residential Customers 158,797 Average Annual PCE Payment per Eligible
Customer
$1,780
PCE Eligible kWh - Community Facility
Customers
35,446 Average PCE Payment per Eligible kWh $0.47
Total PCE Eligible kWh 194,243 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.69
Average Monthly PCE Eligible kWh per
Residential Customer
270 Last Reported PCE Level (per kWh)$0.42
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,477 Effective Residential Rate (per kWh)$0.27
Average Monthly PCE Eligible Community
Facility kWh per person
28 PCE Eligible kWh vs Total kWh Sold 51.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $28,545
Non-Fuel Expense per kWh sold $0.08
Total Expense per kWh sold $0.08
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 202,237 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 35,446 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)136,650 Fuel Efficiency (kWh per gallon of diesel)N/A
Total kWh Sold 374,333 PH Consumption as % of generation N/A
Powerhouse (PH) Consumption kWh 2,493
Total kWh Sold & PH Consumption 376,826
Comments
See Slana, is part of the Slana-Chistochina grid.
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 36 of 181
Chitina PCE
Utility: CHITINA ELECTRIC INC.
Reporting Period: 07/01/12..06/30/13
Community Population 137
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 55
Community Facility Customers 2
Other Customers (Non-PCE)33
Fiscal Year PCE Payments $61,729
PCE Statistical Data
PCE Eligible kWh - Residential Customers 135,404 Average Annual PCE Payment per Eligible
Customer
$1,083
PCE Eligible kWh - Community Facility
Customers
17,870 Average PCE Payment per Eligible kWh $0.40
Total PCE Eligible kWh 153,274 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.71
Average Monthly PCE Eligible kWh per
Residential Customer
205 Last Reported PCE Level (per kWh)$0.39
Average Monthly PCE Eligible kWh per
Community Facility Customer
745 Effective Residential Rate (per kWh)$0.32
Average Monthly PCE Eligible Community
Facility kWh per person
11 PCE Eligible kWh vs Total kWh Sold 31.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 565,197 Fuel Used (Gallons)46,277
Non-Diesel kWh Generated 0 Fuel Cost $200,399
Purchased kWh 0 Average Price of Fuel $4.33
Total Purchased & Generated 565,197 Fuel Cost per kWh sold $0.41
Annual Non-Fuel Expenses $87,794
Non-Fuel Expense per kWh sold $0.18
Total Expense per kWh sold $0.59
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 166,403 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
85.9%
Community Facility kWh Sold 17,870 Line Loss (%)6.1%
Other kWh Sold (Non-PCE)300,970 Fuel Efficiency (kWh per gallon of diesel)12.21
Total kWh Sold 485,243 PH Consumption as % of generation 8.1%
Powerhouse (PH) Consumption kWh 45,658
Total kWh Sold & PH Consumption 530,901
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 37 of 181
Chuathbaluk PCE
Utility: MIDDLE KUSKOKWIM ELECTRIC
Reporting Period: 07/01/12..06/30/13
Community Population 135
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 30
Community Facility Customers 5
Other Customers (Non-PCE)12
Fiscal Year PCE Payments $89,144
PCE Statistical Data
PCE Eligible kWh - Residential Customers 90,691 Average Annual PCE Payment per Eligible
Customer
$2,547
PCE Eligible kWh - Community Facility
Customers
36,393 Average PCE Payment per Eligible kWh $0.70
Total PCE Eligible kWh 127,084 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.80
Average Monthly PCE Eligible kWh per
Residential Customer
252 Last Reported PCE Level (per kWh)$0.61
Average Monthly PCE Eligible kWh per
Community Facility Customer
607 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
22 PCE Eligible kWh vs Total kWh Sold 47.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)28,237
Non-Diesel kWh Generated 0 Fuel Cost $125,697
Purchased kWh 0 Average Price of Fuel $4.45
Total Purchased & Generated 0 Fuel Cost per kWh sold $0.47
Annual Non-Fuel Expenses $81,844
Non-Fuel Expense per kWh sold $0.31
Total Expense per kWh sold $0.77
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 97,096 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 39,985 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)130,901 Fuel Efficiency (kWh per gallon of diesel)N/A
Total kWh Sold 267,982 PH Consumption as % of generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 267,982
Comments
Jul-Jun kWh generated & pwrhouse use not reported due to meter failure
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 38 of 181
Circle PCE
Utility: CIRCLE ELECTRIC LLC
Reporting Period: 07/01/12..06/30/13
Community Population 101
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 38
Community Facility Customers 2
Other Customers (Non-PCE)12
Fiscal Year PCE Payments $68,145
PCE Statistical Data
PCE Eligible kWh - Residential Customers 124,088 Average Annual PCE Payment per Eligible
Customer
$1,704
PCE Eligible kWh - Community Facility
Customers
5,220 Average PCE Payment per Eligible kWh $0.53
Total PCE Eligible kWh 129,308 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.79
Average Monthly PCE Eligible kWh per
Residential Customer
272 Last Reported PCE Level (per kWh)$0.53
Average Monthly PCE Eligible kWh per
Community Facility Customer
218 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per person
4 PCE Eligible kWh vs Total kWh Sold 35.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 408,760 Fuel Used (Gallons)37,254
Non-Diesel kWh Generated 0 Fuel Cost $143,617
Purchased kWh 0 Average Price of Fuel $3.86
Total Purchased & Generated 408,760 Fuel Cost per kWh sold $0.39
Annual Non-Fuel Expenses $99,594
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.66
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 145,552 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
89.6%
Community Facility kWh Sold 5,220 Line Loss (%)10.3%
Other kWh Sold (Non-PCE)215,478 Fuel Efficiency (kWh per gallon of diesel)10.97
Total kWh Sold 366,250 PH Consumption as % of generation 0.1%
Powerhouse (PH) Consumption kWh 524
Total kWh Sold & PH Consumption 366,774
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 39 of 181
Coffman Cove PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/12..06/30/13
Community Population 170
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 146
Community Facility Customers 14
Other Customers (Non-PCE)35
Fiscal Year PCE Payments $34,596
PCE Statistical Data
PCE Eligible kWh - Residential Customers 417,403 Average Annual PCE Payment per Eligible
Customer
$216
PCE Eligible kWh - Community Facility
Customers
65,956 Average PCE Payment per Eligible kWh $0.07
Total PCE Eligible kWh 483,359 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.26
Average Monthly PCE Eligible kWh per
Residential Customer
238 Last Reported PCE Level (per kWh)$0.08
Average Monthly PCE Eligible kWh per
Community Facility Customer
393 Effective Residential Rate (per kWh)$0.18
Average Monthly PCE Eligible Community
Facility kWh per person
32 PCE Eligible kWh vs Total kWh Sold 58.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 9,540 Fuel Used (Gallons)934
Non-Diesel kWh Generated 0 Fuel Cost $3,381
Purchased kWh 0 Average Price of Fuel $3.62
Total Purchased & Generated 9,540 Fuel Cost per kWh sold $0.00
Annual Non-Fuel Expenses $94,925
Non-Fuel Expense per kWh sold $0.12
Total Expense per kWh sold $0.12
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 554,716 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 65,956 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)201,018 Fuel Efficiency (kWh per gallon of diesel)10.21
Total kWh Sold 821,690 PH Consumption as % of generation 83.1%
Powerhouse (PH) Consumption kWh 7,932
Total kWh Sold & PH Consumption 829,622
Comments
See Craig for power generation; Diesel generation is from backup generators
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 40 of 181
Cold Bay PCE
Utility: G & K INC.
Reporting Period: 07/01/12..06/30/13
Community Population 95
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 36
Community Facility Customers 5
Other Customers (Non-PCE)75
Fiscal Year PCE Payments $76,650
PCE Statistical Data
PCE Eligible kWh - Residential Customers 72,482 Average Annual PCE Payment per Eligible
Customer
$1,870
PCE Eligible kWh - Community Facility
Customers
79,800 Average PCE Payment per Eligible kWh $0.50
Total PCE Eligible kWh 152,282 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.71
Average Monthly PCE Eligible kWh per
Residential Customer
168 Last Reported PCE Level (per kWh)$0.52
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,330 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
70 PCE Eligible kWh vs Total kWh Sold 6.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,906,618 Fuel Used (Gallons)215,024
Non-Diesel kWh Generated 0 Fuel Cost $1,082,708
Purchased kWh 0 Average Price of Fuel $5.04
Total Purchased & Generated 2,906,618 Fuel Cost per kWh sold $0.43
Annual Non-Fuel Expenses $631,080
Non-Fuel Expense per kWh sold $0.25
Total Expense per kWh sold $0.68
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 224,203 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
86.6%
Community Facility kWh Sold 160,527 Line Loss (%)7.5%
Other kWh Sold (Non-PCE)2,132,020 Fuel Efficiency (kWh per gallon of diesel)13.52
Total kWh Sold 2,516,750 PH Consumption as % of generation 5.9%
Powerhouse (PH) Consumption kWh 171,470
Total kWh Sold & PH Consumption 2,688,220
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 41 of 181
Cordova PCE
Utility: CORDOVA ELECTRIC
Reporting Period: 07/01/12..06/30/13
Community Population 2289
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 772
Community Facility Customers 59
Other Customers (Non-PCE)810
Fiscal Year PCE Payments $688,140
PCE Statistical Data
PCE Eligible kWh - Residential Customers 3,469,911 Average Annual PCE Payment per Eligible
Customer
$828
PCE Eligible kWh - Community Facility
Customers
1,922,760 Average PCE Payment per Eligible kWh $0.13
Total PCE Eligible kWh 5,392,671 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.39
Average Monthly PCE Eligible kWh per
Residential Customer
375 Last Reported PCE Level (per kWh)$0.14
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,716 Effective Residential Rate (per kWh)$0.25
Average Monthly PCE Eligible Community
Facility kWh per person
70 PCE Eligible kWh vs Total kWh Sold 20.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 10,797,853 Fuel Used (Gallons)821,640
Non-Diesel kWh Generated 17,453,931 Fuel Cost $3,070,073
Purchased kWh 0 Average Price of Fuel $3.74
Total Purchased & Generated 28,251,784 Fuel Cost per kWh sold $0.12
Annual Non-Fuel Expenses $4,664,199
Non-Fuel Expense per kWh sold $0.18
Total Expense per kWh sold $0.30
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 4,801,576 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
91.2%
Community Facility kWh Sold 2,626,612 Line Loss (%)7.1%
Other kWh Sold (Non-PCE)18,351,377 Fuel Efficiency (kWh per gallon of diesel)13.14
Total kWh Sold 25,779,565 PH Consumption as % of generation 1.7%
Powerhouse (PH) Consumption kWh 469,603
Total kWh Sold & PH Consumption 26,249,168
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 42 of 181
Craig PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/12..06/30/13
Community Population 1240
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 660
Community Facility Customers 46
Other Customers (Non-PCE)319
Fiscal Year PCE Payments $248,439
PCE Statistical Data
PCE Eligible kWh - Residential Customers 2,503,300 Average Annual PCE Payment per Eligible
Customer
$352
PCE Eligible kWh - Community Facility
Customers
1,037,741 Average PCE Payment per Eligible kWh $0.07
Total PCE Eligible kWh 3,541,041 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.26
Average Monthly PCE Eligible kWh per
Residential Customer
316 Last Reported PCE Level (per kWh)$0.08
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,880 Effective Residential Rate (per kWh)$0.18
Average Monthly PCE Eligible Community
Facility kWh per person
70 PCE Eligible kWh vs Total kWh Sold 31.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,482,390 Fuel Used (Gallons)193,943
Non-Diesel kWh Generated 0 Fuel Cost $814,212
Purchased kWh 26,339,917 Average Price of Fuel $4.20
Total Purchased & Generated 28,822,307 Fuel Cost per kWh sold $0.07
Annual Non-Fuel Expenses $1,240,447
Non-Fuel Expense per kWh sold $0.11
Total Expense per kWh sold $0.18
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 3,635,793 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
39.4%
Community Facility kWh Sold 1,336,813 Line Loss (%)59.9%
Other kWh Sold (Non-PCE)6,379,839 Fuel Efficiency (kWh per gallon of diesel)12.80
Total kWh Sold 11,352,445 PH Consumption as % of generation 0.7%
Powerhouse (PH) Consumption kWh 198,870
Total kWh Sold & PH Consumption 11,551,315
Comments
Supplies power to Coffman Cove, Hollis,Hydaburg,Klawock,Thorne Bay/Kasaan
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 43 of 181
Crooked Creek PCE
Utility: MIDDLE KUSKOKWIM ELECTRIC
Reporting Period: 07/01/12..06/30/13
Community Population 103
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 35
Community Facility Customers 3
Other Customers (Non-PCE)12
Fiscal Year PCE Payments $90,588
PCE Statistical Data
PCE Eligible kWh - Residential Customers 95,539 Average Annual PCE Payment per Eligible
Customer
$2,384
PCE Eligible kWh - Community Facility
Customers
33,217 Average PCE Payment per Eligible kWh $0.70
Total PCE Eligible kWh 128,756 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.80
Average Monthly PCE Eligible kWh per
Residential Customer
227 Last Reported PCE Level (per kWh)$0.61
Average Monthly PCE Eligible kWh per
Community Facility Customer
923 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
27 PCE Eligible kWh vs Total kWh Sold 51.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 273,925 Fuel Used (Gallons)23,418
Non-Diesel kWh Generated 0 Fuel Cost $104,301
Purchased kWh 0 Average Price of Fuel $4.45
Total Purchased & Generated 273,925 Fuel Cost per kWh sold $0.42
Annual Non-Fuel Expenses $81,844
Non-Fuel Expense per kWh sold $0.33
Total Expense per kWh sold $0.75
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 115,393 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
90.8%
Community Facility kWh Sold 39,528 Line Loss (%)9.2%
Other kWh Sold (Non-PCE)93,865 Fuel Efficiency (kWh per gallon of diesel)11.70
Total kWh Sold 248,786 PH Consumption as % of generation 0.0%
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 248,786
Comments
Powerhouse use not reported
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 44 of 181
Deering PCE
Utility: IPNATCHIAQ ELECTRIC COMPANY
Reporting Period: 07/01/12..06/30/13
Community Population 123
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 43
Community Facility Customers 7
Other Customers (Non-PCE)14
Fiscal Year PCE Payments $115,780
PCE Statistical Data
PCE Eligible kWh - Residential Customers 170,156 Average Annual PCE Payment per Eligible
Customer
$2,316
PCE Eligible kWh - Community Facility
Customers
95,890 Average PCE Payment per Eligible kWh $0.44
Total PCE Eligible kWh 266,046 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.70
Average Monthly PCE Eligible kWh per
Residential Customer
330 Last Reported PCE Level (per kWh)$0.44
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,142 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per person
65 PCE Eligible kWh vs Total kWh Sold 41.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 719,099 Fuel Used (Gallons)55,074
Non-Diesel kWh Generated 0 Fuel Cost $249,293
Purchased kWh 0 Average Price of Fuel $4.53
Total Purchased & Generated 719,099 Fuel Cost per kWh sold $0.39
Annual Non-Fuel Expenses $143,566
Non-Fuel Expense per kWh sold $0.22
Total Expense per kWh sold $0.61
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 216,052 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
89.4%
Community Facility kWh Sold 111,870 Line Loss (%)8.0%
Other kWh Sold (Non-PCE)314,887 Fuel Efficiency (kWh per gallon of diesel)13.06
Total kWh Sold 642,809 PH Consumption as % of generation 2.6%
Powerhouse (PH) Consumption kWh 18,478
Total kWh Sold & PH Consumption 661,287
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 45 of 181
Dillingham; Aleknagik PCE
Utility: NUSHAGAK ELECTRIC AND
Reporting Period: 07/01/12..06/30/13
Community Population 2603
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 987
Community Facility Customers 48
Other Customers (Non-PCE)450
Fiscal Year PCE Payments $1,456,334
PCE Statistical Data
PCE Eligible kWh - Residential Customers 4,046,111 Average Annual PCE Payment per Eligible
Customer
$1,407
PCE Eligible kWh - Community Facility
Customers
924,763 Average PCE Payment per Eligible kWh $0.29
Total PCE Eligible kWh 4,970,874 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.44
Average Monthly PCE Eligible kWh per
Residential Customer
342 Last Reported PCE Level (per kWh)$0.29
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,605 Effective Residential Rate (per kWh)$0.15
Average Monthly PCE Eligible Community
Facility kWh per person
30 PCE Eligible kWh vs Total kWh Sold 27.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 19,168,300 Fuel Used (Gallons)1,269,686
Non-Diesel kWh Generated 0 Fuel Cost $4,899,947
Purchased kWh 0 Average Price of Fuel $3.86
Total Purchased & Generated 19,168,300 Fuel Cost per kWh sold $0.27
Annual Non-Fuel Expenses $3,317,347
Non-Fuel Expense per kWh sold $0.18
Total Expense per kWh sold $0.45
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 5,563,937 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
94.4%
Community Facility kWh Sold 978,353 Line Loss (%)4.0%
Other kWh Sold (Non-PCE)11,545,838 Fuel Efficiency (kWh per gallon of diesel)15.10
Total kWh Sold 18,088,128 PH Consumption as % of generation 1.6%
Powerhouse (PH) Consumption kWh 312,200
Total kWh Sold & PH Consumption 18,400,328
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 46 of 181
Diomede PCE
Utility: DIOMEDE JOINT UTLITIES
Reporting Period: 07/01/12..06/30/13
Community Population 107
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 51
Community Facility Customers 5
Other Customers (Non-PCE)15
Fiscal Year PCE Payments $74,394
PCE Statistical Data
PCE Eligible kWh - Residential Customers 131,703 Average Annual PCE Payment per Eligible
Customer
$1,328
PCE Eligible kWh - Community Facility
Customers
31,084 Average PCE Payment per Eligible kWh $0.46
Total PCE Eligible kWh 162,787 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.60
Average Monthly PCE Eligible kWh per
Residential Customer
215 Last Reported PCE Level (per kWh)$0.46
Average Monthly PCE Eligible kWh per
Community Facility Customer
518 Effective Residential Rate (per kWh)$0.14
Average Monthly PCE Eligible Community
Facility kWh per person
24 PCE Eligible kWh vs Total kWh Sold 33.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 513,695 Fuel Used (Gallons)46,856
Non-Diesel kWh Generated 0 Fuel Cost $230,142
Purchased kWh 0 Average Price of Fuel $4.91
Total Purchased & Generated 513,695 Fuel Cost per kWh sold $0.47
Annual Non-Fuel Expenses $26,117
Non-Fuel Expense per kWh sold $0.05
Total Expense per kWh sold $0.52
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 157,586 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
95.9%
Community Facility kWh Sold 31,960 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)302,885 Fuel Efficiency (kWh per gallon of diesel)10.96
Total kWh Sold 492,431 PH Consumption as % of generation 7.3%
Powerhouse (PH) Consumption kWh 37,489
Total kWh Sold & PH Consumption 529,920
Comments
Inaccurate plant logs; sales > reported generation; Only 2 months non-fuel reptd
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 47 of 181
Dot Lake; Dot Lake Village PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/12..06/30/13
Community Population 67
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 25
Community Facility Customers 2
Other Customers (Non-PCE)18
Fiscal Year PCE Payments $25,930
PCE Statistical Data
PCE Eligible kWh - Residential Customers 91,499 Average Annual PCE Payment per Eligible
Customer
$960
PCE Eligible kWh - Community Facility
Customers
1,822 Average PCE Payment per Eligible kWh $0.28
Total PCE Eligible kWh 93,321 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.50
Average Monthly PCE Eligible kWh per
Residential Customer
305 Last Reported PCE Level (per kWh)$0.29
Average Monthly PCE Eligible kWh per
Community Facility Customer
76 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per person
2 PCE Eligible kWh vs Total kWh Sold 25.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $12,650
Non-Fuel Expense per kWh sold $0.03
Total Expense per kWh sold $0.03
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 117,313 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 19,895 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)227,754 Fuel Efficiency (kWh per gallon of diesel)N/A
Total kWh Sold 364,962 PH Consumption as % of generation N/A
Powerhouse (PH) Consumption kWh 600
Total kWh Sold & PH Consumption 365,562
Comments
See Tok for power generation
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 48 of 181
Eagle; Eagle Village PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/12..06/30/13
Community Population 163
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 132
Community Facility Customers 7
Other Customers (Non-PCE)35
Fiscal Year PCE Payments $146,391
PCE Statistical Data
PCE Eligible kWh - Residential Customers 311,286 Average Annual PCE Payment per Eligible
Customer
$1,053
PCE Eligible kWh - Community Facility
Customers
8,605 Average PCE Payment per Eligible kWh $0.46
Total PCE Eligible kWh 319,891 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.68
Average Monthly PCE Eligible kWh per
Residential Customer
197 Last Reported PCE Level (per kWh)$0.46
Average Monthly PCE Eligible kWh per
Community Facility Customer
102 Effective Residential Rate (per kWh)$0.22
Average Monthly PCE Eligible Community
Facility kWh per person
4 PCE Eligible kWh vs Total kWh Sold 47.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 762,445 Fuel Used (Gallons)55,542
Non-Diesel kWh Generated 0 Fuel Cost $210,217
Purchased kWh 0 Average Price of Fuel $3.78
Total Purchased & Generated 762,445 Fuel Cost per kWh sold $0.31
Annual Non-Fuel Expenses $231,168
Non-Fuel Expense per kWh sold $0.35
Total Expense per kWh sold $0.66
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 369,878 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
87.7%
Community Facility kWh Sold 8,605 Line Loss (%)10.7%
Other kWh Sold (Non-PCE)290,158 Fuel Efficiency (kWh per gallon of diesel)13.73
Total kWh Sold 668,641 PH Consumption as % of generation 1.6%
Powerhouse (PH) Consumption kWh 12,019
Total kWh Sold & PH Consumption 680,660
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 49 of 181
Eek PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 318
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 101
Community Facility Customers 9
Other Customers (Non-PCE)20
Fiscal Year PCE Payments $187,604
PCE Statistical Data
PCE Eligible kWh - Residential Customers 333,621 Average Annual PCE Payment per Eligible
Customer
$1,705
PCE Eligible kWh - Community Facility
Customers
102,280 Average PCE Payment per Eligible kWh $0.43
Total PCE Eligible kWh 435,901 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.63
Average Monthly PCE Eligible kWh per
Residential Customer
275 Last Reported PCE Level (per kWh)$0.43
Average Monthly PCE Eligible kWh per
Community Facility Customer
947 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per person
27 PCE Eligible kWh vs Total kWh Sold 54.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 841,666 Fuel Used (Gallons)65,178
Non-Diesel kWh Generated 0 Fuel Cost $246,237
Purchased kWh 0 Average Price of Fuel $3.78
Total Purchased & Generated 841,666 Fuel Cost per kWh sold $0.31
Annual Non-Fuel Expenses $218,060
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.58
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 355,292 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
94.5%
Community Facility kWh Sold 102,280 Line Loss (%)4.1%
Other kWh Sold (Non-PCE)337,668 Fuel Efficiency (kWh per gallon of diesel)12.91
Total kWh Sold 795,240 PH Consumption as % of generation 1.4%
Powerhouse (PH) Consumption kWh 11,931
Total kWh Sold & PH Consumption 807,171
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 50 of 181
Egegik PCE
Utility: CITY OF EGEGIK
Reporting Period: 07/01/12..06/30/13
Community Population 113
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 71
Community Facility Customers 17
Other Customers (Non-PCE)15
Fiscal Year PCE Payments $131,794
PCE Statistical Data
PCE Eligible kWh - Residential Customers 135,102 Average Annual PCE Payment per Eligible
Customer
$1,498
PCE Eligible kWh - Community Facility
Customers
93,474 Average PCE Payment per Eligible kWh $0.58
Total PCE Eligible kWh 228,576 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.86
Average Monthly PCE Eligible kWh per
Residential Customer
159 Last Reported PCE Level (per kWh)$0.52
Average Monthly PCE Eligible kWh per
Community Facility Customer
458 Effective Residential Rate (per kWh)$0.34
Average Monthly PCE Eligible Community
Facility kWh per person
69 PCE Eligible kWh vs Total kWh Sold 40.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 606,950 Fuel Used (Gallons)53,372
Non-Diesel kWh Generated 0 Fuel Cost $254,219
Purchased kWh 0 Average Price of Fuel $4.76
Total Purchased & Generated 606,950 Fuel Cost per kWh sold $0.45
Annual Non-Fuel Expenses $153,559
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.73
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 149,322 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
92.3%
Community Facility kWh Sold 122,979 Line Loss (%)7.4%
Other kWh Sold (Non-PCE)287,784 Fuel Efficiency (kWh per gallon of diesel)11.37
Total kWh Sold 560,085 PH Consumption as % of generation 0.3%
Powerhouse (PH) Consumption kWh 1,890
Total kWh Sold & PH Consumption 561,975
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 51 of 181
Ekwok PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 115
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 41
Community Facility Customers 6
Other Customers (Non-PCE)28
Fiscal Year PCE Payments $99,720
PCE Statistical Data
PCE Eligible kWh - Residential Customers 171,641 Average Annual PCE Payment per Eligible
Customer
$2,122
PCE Eligible kWh - Community Facility
Customers
27,952 Average PCE Payment per Eligible kWh $0.50
Total PCE Eligible kWh 199,593 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.71
Average Monthly PCE Eligible kWh per
Residential Customer
349 Last Reported PCE Level (per kWh)$0.51
Average Monthly PCE Eligible kWh per
Community Facility Customer
388 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per person
20 PCE Eligible kWh vs Total kWh Sold 42.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 563,269 Fuel Used (Gallons)46,297
Non-Diesel kWh Generated 0 Fuel Cost $207,002
Purchased kWh 0 Average Price of Fuel $4.47
Total Purchased & Generated 563,269 Fuel Cost per kWh sold $0.44
Annual Non-Fuel Expenses $130,344
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.71
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 212,870 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
84.4%
Community Facility kWh Sold 32,032 Line Loss (%)5.5%
Other kWh Sold (Non-PCE)230,447 Fuel Efficiency (kWh per gallon of diesel)12.17
Total kWh Sold 475,349 PH Consumption as % of generation 10.1%
Powerhouse (PH) Consumption kWh 56,695
Total kWh Sold & PH Consumption 532,044
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 52 of 181
Elfin Cove PCE
Utility: ELFIN COVE UTILITY COMMISSION
Reporting Period: 07/01/12..06/30/13
Community Population 18
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 45
Community Facility Customers 6
Other Customers (Non-PCE)30
Fiscal Year PCE Payments $24,509
PCE Statistical Data
PCE Eligible kWh - Residential Customers 56,615 Average Annual PCE Payment per Eligible
Customer
$481
PCE Eligible kWh - Community Facility
Customers
10,596 Average PCE Payment per Eligible kWh $0.36
Total PCE Eligible kWh 67,211 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.80
Average Monthly PCE Eligible kWh per
Residential Customer
105 Last Reported PCE Level (per kWh)$0.36
Average Monthly PCE Eligible kWh per
Community Facility Customer
147 Effective Residential Rate (per kWh)$0.44
Average Monthly PCE Eligible Community
Facility kWh per person
49 PCE Eligible kWh vs Total kWh Sold 28.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 290,910 Fuel Used (Gallons)24,119
Non-Diesel kWh Generated 0 Fuel Cost $122,214
Purchased kWh 0 Average Price of Fuel $5.07
Total Purchased & Generated 290,910 Fuel Cost per kWh sold $0.52
Annual Non-Fuel Expenses $45,229
Non-Fuel Expense per kWh sold $0.19
Total Expense per kWh sold $0.71
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 92,970 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
81.5%
Community Facility kWh Sold 10,596 Line Loss (%)7.5%
Other kWh Sold (Non-PCE)133,414 Fuel Efficiency (kWh per gallon of diesel)12.06
Total kWh Sold 236,980 PH Consumption as % of generation 11.0%
Powerhouse (PH) Consumption kWh 32,098
Total kWh Sold & PH Consumption 269,078
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 53 of 181
Elim PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 332
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 96
Community Facility Customers 11
Other Customers (Non-PCE)20
Fiscal Year PCE Payments $209,457
PCE Statistical Data
PCE Eligible kWh - Residential Customers 391,903 Average Annual PCE Payment per Eligible
Customer
$1,958
PCE Eligible kWh - Community Facility
Customers
168,306 Average PCE Payment per Eligible kWh $0.37
Total PCE Eligible kWh 560,209 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.60
Average Monthly PCE Eligible kWh per
Residential Customer
340 Last Reported PCE Level (per kWh)$0.40
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,275 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
42 PCE Eligible kWh vs Total kWh Sold 49.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,190,778 Fuel Used (Gallons)92,012
Non-Diesel kWh Generated 0 Fuel Cost $358,794
Purchased kWh 0 Average Price of Fuel $3.90
Total Purchased & Generated 1,190,778 Fuel Cost per kWh sold $0.32
Annual Non-Fuel Expenses $310,908
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.59
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 473,953 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
95.2%
Community Facility kWh Sold 162,546 Line Loss (%)3.5%
Other kWh Sold (Non-PCE)497,346 Fuel Efficiency (kWh per gallon of diesel)12.94
Total kWh Sold 1,133,845 PH Consumption as % of generation 1.3%
Powerhouse (PH) Consumption kWh 15,594
Total kWh Sold & PH Consumption 1,149,439
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 54 of 181
Emmonak PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 796
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 218
Community Facility Customers 12
Other Customers (Non-PCE)59
Fiscal Year PCE Payments $505,974
PCE Statistical Data
PCE Eligible kWh - Residential Customers 800,254 Average Annual PCE Payment per Eligible
Customer
$2,200
PCE Eligible kWh - Community Facility
Customers
650,137 Average PCE Payment per Eligible kWh $0.35
Total PCE Eligible kWh 1,450,391 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.57
Average Monthly PCE Eligible kWh per
Residential Customer
306 Last Reported PCE Level (per kWh)$0.38
Average Monthly PCE Eligible kWh per
Community Facility Customer
4,515 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
68 PCE Eligible kWh vs Total kWh Sold 41.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 3,046,790 Fuel Used (Gallons)233,567
Non-Diesel kWh Generated 611,365 Fuel Cost $898,877
Purchased kWh 0 Average Price of Fuel $3.85
Total Purchased & Generated 3,658,155 Fuel Cost per kWh sold $0.26
Annual Non-Fuel Expenses $949,767
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.53
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,117,355 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
94.7%
Community Facility kWh Sold 735,417 Line Loss (%)3.4%
Other kWh Sold (Non-PCE)1,610,920 Fuel Efficiency (kWh per gallon of diesel)13.04
Total kWh Sold 3,463,692 PH Consumption as % of generation 1.9%
Powerhouse (PH) Consumption kWh 68,834
Total kWh Sold & PH Consumption 3,532,526
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 55 of 181
False Pass PCE
Utility: CITY OF FALSE PASS
Reporting Period: 07/01/12..06/30/13
Community Population 37
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 25
Community Facility Customers 11
Other Customers (Non-PCE)17
Fiscal Year PCE Payments $27,531
PCE Statistical Data
PCE Eligible kWh - Residential Customers 73,574 Average Annual PCE Payment per Eligible
Customer
$765
PCE Eligible kWh - Community Facility
Customers
30,175 Average PCE Payment per Eligible kWh $0.27
Total PCE Eligible kWh 103,749 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.42
Average Monthly PCE Eligible kWh per
Residential Customer
245 Last Reported PCE Level (per kWh)$0.28
Average Monthly PCE Eligible kWh per
Community Facility Customer
229 Effective Residential Rate (per kWh)$0.14
Average Monthly PCE Eligible Community
Facility kWh per person
68 PCE Eligible kWh vs Total kWh Sold 17.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 711,450 Fuel Used (Gallons)53,153
Non-Diesel kWh Generated 0 Fuel Cost $202,752
Purchased kWh 0 Average Price of Fuel $3.81
Total Purchased & Generated 711,450 Fuel Cost per kWh sold $0.35
Annual Non-Fuel Expenses $38,222
Non-Fuel Expense per kWh sold $0.07
Total Expense per kWh sold $0.42
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 91,420 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
81.4%
Community Facility kWh Sold 63,761 Line Loss (%)12.6%
Other kWh Sold (Non-PCE)423,622 Fuel Efficiency (kWh per gallon of diesel)13.38
Total kWh Sold 578,803 PH Consumption as % of generation 6.0%
Powerhouse (PH) Consumption kWh 42,649
Total kWh Sold & PH Consumption 621,452
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 56 of 181
Fort Yukon PCE
Utility: GWITCHYAA ZHEE UTILITY CO.
Reporting Period: 07/01/12..06/30/13
Community Population 598
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 260
Community Facility Customers 11
Other Customers (Non-PCE)83
Fiscal Year PCE Payments $547,626
PCE Statistical Data
PCE Eligible kWh - Residential Customers 909,212 Average Annual PCE Payment per Eligible
Customer
$2,021
PCE Eligible kWh - Community Facility
Customers
229,198 Average PCE Payment per Eligible kWh $0.48
Total PCE Eligible kWh 1,138,410 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.66
Average Monthly PCE Eligible kWh per
Residential Customer
291 Last Reported PCE Level (per kWh)$0.49
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,736 Effective Residential Rate (per kWh)$0.17
Average Monthly PCE Eligible Community
Facility kWh per person
32 PCE Eligible kWh vs Total kWh Sold 42.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 3,284,005 Fuel Used (Gallons)218,949
Non-Diesel kWh Generated 0 Fuel Cost $1,234,024
Purchased kWh 0 Average Price of Fuel $5.64
Total Purchased & Generated 3,284,005 Fuel Cost per kWh sold $0.46
Annual Non-Fuel Expenses $326,362
Non-Fuel Expense per kWh sold $0.12
Total Expense per kWh sold $0.58
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,137,066 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
82.3%
Community Facility kWh Sold 229,198 Line Loss (%)16.4%
Other kWh Sold (Non-PCE)1,336,773 Fuel Efficiency (kWh per gallon of diesel)15.00
Total kWh Sold 2,703,037 PH Consumption as % of generation 1.3%
Powerhouse (PH) Consumption kWh 42,254
Total kWh Sold & PH Consumption 2,745,291
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 57 of 181
Galena PCE
Utility: CITY OF GALENA
Reporting Period: 07/01/12..06/30/13
Community Population 487
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 204
Community Facility Customers 8
Other Customers (Non-PCE)160
Fiscal Year PCE Payments $350,622
PCE Statistical Data
PCE Eligible kWh - Residential Customers 694,711 Average Annual PCE Payment per Eligible
Customer
$1,654
PCE Eligible kWh - Community Facility
Customers
385,468 Average PCE Payment per Eligible kWh $0.32
Total PCE Eligible kWh 1,080,179 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.67
Average Monthly PCE Eligible kWh per
Residential Customer
284 Last Reported PCE Level (per kWh)$0.32
Average Monthly PCE Eligible kWh per
Community Facility Customer
4,015 Effective Residential Rate (per kWh)$0.35
Average Monthly PCE Eligible Community
Facility kWh per person
66 PCE Eligible kWh vs Total kWh Sold 24.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 5,630,437 Fuel Used (Gallons)423,043
Non-Diesel kWh Generated 0 Fuel Cost $1,563,790
Purchased kWh 0 Average Price of Fuel $3.70
Total Purchased & Generated 5,630,437 Fuel Cost per kWh sold $0.35
Annual Non-Fuel Expenses $577,769
Non-Fuel Expense per kWh sold $0.13
Total Expense per kWh sold $0.48
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 858,797 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
79.4%
Community Facility kWh Sold 572,526 Line Loss (%)17.9%
Other kWh Sold (Non-PCE)3,038,023 Fuel Efficiency (kWh per gallon of diesel)13.31
Total kWh Sold 4,469,346 PH Consumption as % of generation 2.7%
Powerhouse (PH) Consumption kWh 154,529
Total kWh Sold & PH Consumption 4,623,875
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 58 of 181
Gambell PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 677
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 168
Community Facility Customers 13
Other Customers (Non-PCE)23
Fiscal Year PCE Payments $285,144
PCE Statistical Data
PCE Eligible kWh - Residential Customers 601,614 Average Annual PCE Payment per Eligible
Customer
$1,575
PCE Eligible kWh - Community Facility
Customers
275,398 Average PCE Payment per Eligible kWh $0.33
Total PCE Eligible kWh 877,012 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.54
Average Monthly PCE Eligible kWh per
Residential Customer
298 Last Reported PCE Level (per kWh)$0.35
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,765 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
34 PCE Eligible kWh vs Total kWh Sold 47.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,470,466 Fuel Used (Gallons)108,622
Non-Diesel kWh Generated 564,905 Fuel Cost $415,218
Purchased kWh 0 Average Price of Fuel $3.82
Total Purchased & Generated 2,035,371 Fuel Cost per kWh sold $0.22
Annual Non-Fuel Expenses $508,775
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.50
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 802,474 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
91.2%
Community Facility kWh Sold 275,398 Line Loss (%)3.8%
Other kWh Sold (Non-PCE)777,575 Fuel Efficiency (kWh per gallon of diesel)13.54
Total kWh Sold 1,855,447 PH Consumption as % of generation 5.0%
Powerhouse (PH) Consumption kWh 102,616
Total kWh Sold & PH Consumption 1,958,063
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 59 of 181
Golovin PCE
Utility: GOLOVIN POWER UTILITIES
Reporting Period: 07/01/12..06/30/13
Community Population 171
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 53
Community Facility Customers 11
Other Customers (Non-PCE)34
Fiscal Year PCE Payments $107,660
PCE Statistical Data
PCE Eligible kWh - Residential Customers 215,863 Average Annual PCE Payment per Eligible
Customer
$1,682
PCE Eligible kWh - Community Facility
Customers
107,654 Average PCE Payment per Eligible kWh $0.33
Total PCE Eligible kWh 323,517 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.60
Average Monthly PCE Eligible kWh per
Residential Customer
339 Last Reported PCE Level (per kWh)$0.33
Average Monthly PCE Eligible kWh per
Community Facility Customer
816 Effective Residential Rate (per kWh)$0.27
Average Monthly PCE Eligible Community
Facility kWh per person
52 PCE Eligible kWh vs Total kWh Sold 42.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 840,400 Fuel Used (Gallons)65,573
Non-Diesel kWh Generated 0 Fuel Cost $250,616
Purchased kWh 0 Average Price of Fuel $3.82
Total Purchased & Generated 840,400 Fuel Cost per kWh sold $0.33
Annual Non-Fuel Expenses $149,814
Non-Fuel Expense per kWh sold $0.20
Total Expense per kWh sold $0.53
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 247,279 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
89.6%
Community Facility kWh Sold 107,981 Line Loss (%)6.9%
Other kWh Sold (Non-PCE)397,985 Fuel Efficiency (kWh per gallon of diesel)12.82
Total kWh Sold 753,245 PH Consumption as % of generation 3.5%
Powerhouse (PH) Consumption kWh 29,116
Total kWh Sold & PH Consumption 782,361
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 60 of 181
Goodnews Bay PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 246
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 81
Community Facility Customers 11
Other Customers (Non-PCE)11
Fiscal Year PCE Payments $172,389
PCE Statistical Data
PCE Eligible kWh - Residential Customers 323,873 Average Annual PCE Payment per Eligible
Customer
$1,874
PCE Eligible kWh - Community Facility
Customers
98,268 Average PCE Payment per Eligible kWh $0.41
Total PCE Eligible kWh 422,141 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.63
Average Monthly PCE Eligible kWh per
Residential Customer
333 Last Reported PCE Level (per kWh)$0.43
Average Monthly PCE Eligible kWh per
Community Facility Customer
744 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per person
33 PCE Eligible kWh vs Total kWh Sold 56.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 788,752 Fuel Used (Gallons)58,335
Non-Diesel kWh Generated 0 Fuel Cost $235,781
Purchased kWh 0 Average Price of Fuel $4.04
Total Purchased & Generated 788,752 Fuel Cost per kWh sold $0.31
Annual Non-Fuel Expenses $206,169
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.59
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 392,527 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
95.3%
Community Facility kWh Sold 99,668 Line Loss (%)2.8%
Other kWh Sold (Non-PCE)259,682 Fuel Efficiency (kWh per gallon of diesel)13.52
Total kWh Sold 751,877 PH Consumption as % of generation 1.9%
Powerhouse (PH) Consumption kWh 14,648
Total kWh Sold & PH Consumption 766,525
Comments
Unreliable generation; 5 months gen < sales
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 61 of 181
Grayling PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 189
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 58
Community Facility Customers 11
Other Customers (Non-PCE)12
Fiscal Year PCE Payments $138,873
PCE Statistical Data
PCE Eligible kWh - Residential Customers 203,249 Average Annual PCE Payment per Eligible
Customer
$2,013
PCE Eligible kWh - Community Facility
Customers
133,991 Average PCE Payment per Eligible kWh $0.41
Total PCE Eligible kWh 337,240 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.63
Average Monthly PCE Eligible kWh per
Residential Customer
292 Last Reported PCE Level (per kWh)$0.43
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,015 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per person
59 PCE Eligible kWh vs Total kWh Sold 61.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 602,529 Fuel Used (Gallons)51,295
Non-Diesel kWh Generated 0 Fuel Cost $194,182
Purchased kWh 0 Average Price of Fuel $3.79
Total Purchased & Generated 602,529 Fuel Cost per kWh sold $0.35
Annual Non-Fuel Expenses $150,314
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.63
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 218,324 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
91.0%
Community Facility kWh Sold 134,873 Line Loss (%)3.6%
Other kWh Sold (Non-PCE)194,980 Fuel Efficiency (kWh per gallon of diesel)11.75
Total kWh Sold 548,177 PH Consumption as % of generation 5.4%
Powerhouse (PH) Consumption kWh 32,748
Total kWh Sold & PH Consumption 580,925
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 62 of 181
Gustavus PCE
Utility: GUSTAVUS ELECTRIC CO
Reporting Period: 07/01/12..06/30/13
Community Population 460
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 479
Community Facility Customers 6
Other Customers (Non-PCE)151
Fiscal Year PCE Payments $174,470
PCE Statistical Data
PCE Eligible kWh - Residential Customers 880,249 Average Annual PCE Payment per Eligible
Customer
$360
PCE Eligible kWh - Community Facility
Customers
44,063 Average PCE Payment per Eligible kWh $0.19
Total PCE Eligible kWh 924,312 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.41
Average Monthly PCE Eligible kWh per
Residential Customer
153 Last Reported PCE Level (per kWh)$0.13
Average Monthly PCE Eligible kWh per
Community Facility Customer
612 Effective Residential Rate (per kWh)$0.28
Average Monthly PCE Eligible Community
Facility kWh per person
8 PCE Eligible kWh vs Total kWh Sold 49.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 58,769 Fuel Used (Gallons)4,617
Non-Diesel kWh Generated 2,046,588 Fuel Cost $19,693
Purchased kWh 0 Average Price of Fuel $4.27
Total Purchased & Generated 2,105,357 Fuel Cost per kWh sold $0.01
Annual Non-Fuel Expenses $778,997
Non-Fuel Expense per kWh sold $0.42
Total Expense per kWh sold $0.43
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 984,251 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
88.1%
Community Facility kWh Sold 44,063 Line Loss (%)9.9%
Other kWh Sold (Non-PCE)826,706 Fuel Efficiency (kWh per gallon of diesel)12.73
Total kWh Sold 1,855,020 PH Consumption as % of generation 2.0%
Powerhouse (PH) Consumption kWh 42,470
Total kWh Sold & PH Consumption 1,897,490
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 63 of 181
Haines; Covenant Life PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/12..06/30/13
Community Population 2705
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 1,075
Community Facility Customers 32
Other Customers (Non-PCE)344
Fiscal Year PCE Payments $283,436
PCE Statistical Data
PCE Eligible kWh - Residential Customers 3,842,619 Average Annual PCE Payment per Eligible
Customer
$256
PCE Eligible kWh - Community Facility
Customers
990,483 Average PCE Payment per Eligible kWh $0.06
Total PCE Eligible kWh 4,833,102 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.26
Average Monthly PCE Eligible kWh per
Residential Customer
298 Last Reported PCE Level (per kWh)$0.08
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,579 Effective Residential Rate (per kWh)$0.18
Average Monthly PCE Eligible Community
Facility kWh per person
31 PCE Eligible kWh vs Total kWh Sold 38.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,276,020 Fuel Used (Gallons)91,697
Non-Diesel kWh Generated 0 Fuel Cost $365,994
Purchased kWh 13,457,478 Average Price of Fuel $3.99
Total Purchased & Generated 14,733,498 Fuel Cost per kWh sold $0.03
Annual Non-Fuel Expenses $1,026,794
Non-Fuel Expense per kWh sold $0.08
Total Expense per kWh sold $0.11
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 5,595,717 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
84.7%
Community Facility kWh Sold 996,675 Line Loss (%)13.0%
Other kWh Sold (Non-PCE)5,891,182 Fuel Efficiency (kWh per gallon of diesel)13.92
Total kWh Sold 12,483,574 PH Consumption as % of generation 2.3%
Powerhouse (PH) Consumption kWh 332,400
Total kWh Sold & PH Consumption 12,815,974
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 64 of 181
Healy Lake PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/12..06/30/13
Community Population 13
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 3
Community Facility Customers 0
Other Customers (Non-PCE)1
Fiscal Year PCE Payments $10,180
PCE Statistical Data
PCE Eligible kWh - Residential Customers 17,120 Average Annual PCE Payment per Eligible
Customer
$3,393
PCE Eligible kWh - Community Facility
Customers
0 Average PCE Payment per Eligible kWh $0.59
Total PCE Eligible kWh 17,120 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.74
Average Monthly PCE Eligible kWh per
Residential Customer
476 Last Reported PCE Level (per kWh)$0.81
Average Monthly PCE Eligible kWh per
Community Facility Customer
0 Effective Residential Rate (per kWh)$0.92
Average Monthly PCE Eligible Community
Facility kWh per person
0 PCE Eligible kWh vs Total kWh Sold 43.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 52,896 Fuel Used (Gallons)8,107
Non-Diesel kWh Generated 0 Fuel Cost $34,090
Purchased kWh 0 Average Price of Fuel $4.21
Total Purchased & Generated 52,896 Fuel Cost per kWh sold $0.86
Annual Non-Fuel Expenses $41,769
Non-Fuel Expense per kWh sold $1.05
Total Expense per kWh sold $1.91
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 18,657 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
75.1%
Community Facility kWh Sold 3,957 Line Loss (%)21.7%
Other kWh Sold (Non-PCE)17,118 Fuel Efficiency (kWh per gallon of diesel)6.52
Total kWh Sold 39,732 PH Consumption as % of generation 3.2%
Powerhouse (PH) Consumption kWh 1,710
Total kWh Sold & PH Consumption 41,442
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 65 of 181
Hollis PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/12..06/30/13
Community Population 106
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 119
Community Facility Customers 1
Other Customers (Non-PCE)23
Fiscal Year PCE Payments $24,460
PCE Statistical Data
PCE Eligible kWh - Residential Customers 344,423 Average Annual PCE Payment per Eligible
Customer
$204
PCE Eligible kWh - Community Facility
Customers
4,404 Average PCE Payment per Eligible kWh $0.07
Total PCE Eligible kWh 348,827 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.26
Average Monthly PCE Eligible kWh per
Residential Customer
241 Last Reported PCE Level (per kWh)$0.08
Average Monthly PCE Eligible kWh per
Community Facility Customer
367 Effective Residential Rate (per kWh)$0.18
Average Monthly PCE Eligible Community
Facility kWh per person
3 PCE Eligible kWh vs Total kWh Sold 39.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $58,244
Non-Fuel Expense per kWh sold $0.07
Total Expense per kWh sold $0.07
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 551,907 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 4,404 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)338,616 Fuel Efficiency (kWh per gallon of diesel)N/A
Total kWh Sold 894,927 PH Consumption as % of generation N/A
Powerhouse (PH) Consumption kWh 9,069
Total kWh Sold & PH Consumption 903,996
Comments
See Craig for power generation
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 66 of 181
Holy Cross PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 176
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 76
Community Facility Customers 11
Other Customers (Non-PCE)13
Fiscal Year PCE Payments $141,467
PCE Statistical Data
PCE Eligible kWh - Residential Customers 259,197 Average Annual PCE Payment per Eligible
Customer
$1,626
PCE Eligible kWh - Community Facility
Customers
117,173 Average PCE Payment per Eligible kWh $0.38
Total PCE Eligible kWh 376,370 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.60
Average Monthly PCE Eligible kWh per
Residential Customer
284 Last Reported PCE Level (per kWh)$0.40
Average Monthly PCE Eligible kWh per
Community Facility Customer
888 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
55 PCE Eligible kWh vs Total kWh Sold 60.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 648,055 Fuel Used (Gallons)51,865
Non-Diesel kWh Generated 0 Fuel Cost $193,192
Purchased kWh 0 Average Price of Fuel $3.72
Total Purchased & Generated 648,055 Fuel Cost per kWh sold $0.31
Annual Non-Fuel Expenses $170,844
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.58
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 313,669 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
96.1%
Community Facility kWh Sold 120,761 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)188,618 Fuel Efficiency (kWh per gallon of diesel)12.50
Total kWh Sold 623,048 PH Consumption as % of generation 4.7%
Powerhouse (PH) Consumption kWh 30,654
Total kWh Sold & PH Consumption 653,702
Comments
Unreliable generation; annual gen < sales
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 67 of 181
Hoonah PCE
Utility: INSIDE PASSAGE ELECTRIC
Reporting Period: 07/01/12..06/30/13
Community Population 753
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 371
Community Facility Customers 28
Other Customers (Non-PCE)73
Fiscal Year PCE Payments $858,064
PCE Statistical Data
PCE Eligible kWh - Residential Customers 1,449,839 Average Annual PCE Payment per Eligible
Customer
$2,151
PCE Eligible kWh - Community Facility
Customers
557,663 Average PCE Payment per Eligible kWh $0.43
Total PCE Eligible kWh 2,007,502 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.68
Average Monthly PCE Eligible kWh per
Residential Customer
326 Last Reported PCE Level (per kWh)$0.46
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,660 Effective Residential Rate (per kWh)$0.23
Average Monthly PCE Eligible Community
Facility kWh per person
62 PCE Eligible kWh vs Total kWh Sold 47.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 4,659,732 Fuel Used (Gallons)315,632
Non-Diesel kWh Generated 0 Fuel Cost $1,322,017
Purchased kWh 0 Average Price of Fuel $4.19
Total Purchased & Generated 4,659,732 Fuel Cost per kWh sold $0.31
Annual Non-Fuel Expenses $919,579
Non-Fuel Expense per kWh sold $0.22
Total Expense per kWh sold $0.52
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,768,395 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
91.7%
Community Facility kWh Sold 589,634 Line Loss (%)6.6%
Other kWh Sold (Non-PCE)1,916,503 Fuel Efficiency (kWh per gallon of diesel)14.76
Total kWh Sold 4,274,532 PH Consumption as % of generation 1.7%
Powerhouse (PH) Consumption kWh 77,733
Total kWh Sold & PH Consumption 4,352,265
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 68 of 181
Hooper Bay PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 1137
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 270
Community Facility Customers 15
Other Customers (Non-PCE)35
Fiscal Year PCE Payments $565,355
PCE Statistical Data
PCE Eligible kWh - Residential Customers 912,027 Average Annual PCE Payment per Eligible
Customer
$1,984
PCE Eligible kWh - Community Facility
Customers
640,195 Average PCE Payment per Eligible kWh $0.36
Total PCE Eligible kWh 1,552,222 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.57
Average Monthly PCE Eligible kWh per
Residential Customer
281 Last Reported PCE Level (per kWh)$0.38
Average Monthly PCE Eligible kWh per
Community Facility Customer
3,557 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
47 PCE Eligible kWh vs Total kWh Sold 48.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,675,469 Fuel Used (Gallons)199,573
Non-Diesel kWh Generated 713,768 Fuel Cost $811,731
Purchased kWh 0 Average Price of Fuel $4.07
Total Purchased & Generated 3,389,237 Fuel Cost per kWh sold $0.25
Annual Non-Fuel Expenses $880,228
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.53
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,207,872 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
94.7%
Community Facility kWh Sold 640,195 Line Loss (%)3.3%
Other kWh Sold (Non-PCE)1,362,025 Fuel Efficiency (kWh per gallon of diesel)13.41
Total kWh Sold 3,210,092 PH Consumption as % of generation 2.0%
Powerhouse (PH) Consumption kWh 68,525
Total kWh Sold & PH Consumption 3,278,617
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 69 of 181
Hughes PCE
Utility: HUGHES POWER & LIGHT
Reporting Period: 07/01/12..06/30/13
Community Population 78
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 36
Community Facility Customers 3
Other Customers (Non-PCE)14
Fiscal Year PCE Payments $116,108
PCE Statistical Data
PCE Eligible kWh - Residential Customers 139,514 Average Annual PCE Payment per Eligible
Customer
$2,977
PCE Eligible kWh - Community Facility
Customers
65,262 Average PCE Payment per Eligible kWh $0.57
Total PCE Eligible kWh 204,776 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.71
Average Monthly PCE Eligible kWh per
Residential Customer
323 Last Reported PCE Level (per kWh)$0.57
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,813 Effective Residential Rate (per kWh)$0.14
Average Monthly PCE Eligible Community
Facility kWh per person
70 PCE Eligible kWh vs Total kWh Sold 61.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 457,936 Fuel Used (Gallons)46,995
Non-Diesel kWh Generated 0 Fuel Cost $289,735
Purchased kWh 0 Average Price of Fuel $6.17
Total Purchased & Generated 457,936 Fuel Cost per kWh sold $0.87
Annual Non-Fuel Expenses $63,343
Non-Fuel Expense per kWh sold $0.19
Total Expense per kWh sold $1.07
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 163,417 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
72.3%
Community Facility kWh Sold 80,555 Line Loss (%)19.2%
Other kWh Sold (Non-PCE)87,344 Fuel Efficiency (kWh per gallon of diesel)9.74
Total kWh Sold 331,316 PH Consumption as % of generation 8.5%
Powerhouse (PH) Consumption kWh 38,741
Total kWh Sold & PH Consumption 370,057
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 70 of 181
Huslia PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 299
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 106
Community Facility Customers 15
Other Customers (Non-PCE)16
Fiscal Year PCE Payments $204,760
PCE Statistical Data
PCE Eligible kWh - Residential Customers 411,170 Average Annual PCE Payment per Eligible
Customer
$1,692
PCE Eligible kWh - Community Facility
Customers
121,607 Average PCE Payment per Eligible kWh $0.38
Total PCE Eligible kWh 532,777 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.60
Average Monthly PCE Eligible kWh per
Residential Customer
323 Last Reported PCE Level (per kWh)$0.41
Average Monthly PCE Eligible kWh per
Community Facility Customer
676 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
34 PCE Eligible kWh vs Total kWh Sold 54.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,020,465 Fuel Used (Gallons)73,950
Non-Diesel kWh Generated 0 Fuel Cost $292,283
Purchased kWh 0 Average Price of Fuel $3.95
Total Purchased & Generated 1,020,465 Fuel Cost per kWh sold $0.30
Annual Non-Fuel Expenses $268,435
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.57
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 559,522 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
95.9%
Community Facility kWh Sold 121,607 Line Loss (%)2.1%
Other kWh Sold (Non-PCE)297,823 Fuel Efficiency (kWh per gallon of diesel)13.80
Total kWh Sold 978,952 PH Consumption as % of generation 2.0%
Powerhouse (PH) Consumption kWh 20,354
Total kWh Sold & PH Consumption 999,306
Comments
Sep, Mar reported generation < sales
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 71 of 181
Hydaburg PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/12..06/30/13
Community Population 406
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 126
Community Facility Customers 9
Other Customers (Non-PCE)45
Fiscal Year PCE Payments $40,848
PCE Statistical Data
PCE Eligible kWh - Residential Customers 529,231 Average Annual PCE Payment per Eligible
Customer
$303
PCE Eligible kWh - Community Facility
Customers
52,455 Average PCE Payment per Eligible kWh $0.07
Total PCE Eligible kWh 581,686 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.26
Average Monthly PCE Eligible kWh per
Residential Customer
350 Last Reported PCE Level (per kWh)$0.08
Average Monthly PCE Eligible kWh per
Community Facility Customer
486 Effective Residential Rate (per kWh)$0.18
Average Monthly PCE Eligible Community
Facility kWh per person
11 PCE Eligible kWh vs Total kWh Sold 45.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $79,062
Non-Fuel Expense per kWh sold $0.06
Total Expense per kWh sold $0.06
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 677,189 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 60,889 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)540,189 Fuel Efficiency (kWh per gallon of diesel)N/A
Total kWh Sold 1,278,267 PH Consumption as % of generation N/A
Powerhouse (PH) Consumption kWh 26,894
Total kWh Sold & PH Consumption 1,305,161
Comments
See Craig for power generation
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 72 of 181
Igiugig PCE
Utility: IGIUGIG ELECTRIC COMPANY
Reporting Period: 07/01/12..06/30/13
Community Population 59
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 26
Community Facility Customers 12
Other Customers (Non-PCE)13
Fiscal Year PCE Payments $70,260
PCE Statistical Data
PCE Eligible kWh - Residential Customers 82,459 Average Annual PCE Payment per Eligible
Customer
$1,849
PCE Eligible kWh - Community Facility
Customers
48,899 Average PCE Payment per Eligible kWh $0.53
Total PCE Eligible kWh 131,358 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.81
Average Monthly PCE Eligible kWh per
Residential Customer
264 Last Reported PCE Level (per kWh)$0.59
Average Monthly PCE Eligible kWh per
Community Facility Customer
340 Effective Residential Rate (per kWh)$0.22
Average Monthly PCE Eligible Community
Facility kWh per person
69 PCE Eligible kWh vs Total kWh Sold 45.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 353,535 Fuel Used (Gallons)30,323
Non-Diesel kWh Generated 0 Fuel Cost $179,236
Purchased kWh 0 Average Price of Fuel $5.91
Total Purchased & Generated 353,535 Fuel Cost per kWh sold $0.62
Annual Non-Fuel Expenses $30,120
Non-Fuel Expense per kWh sold $0.10
Total Expense per kWh sold $0.72
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 92,347 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
82.2%
Community Facility kWh Sold 77,127 Line Loss (%)13.4%
Other kWh Sold (Non-PCE)121,154 Fuel Efficiency (kWh per gallon of diesel)11.66
Total kWh Sold 290,628 PH Consumption as % of generation 4.4%
Powerhouse (PH) Consumption kWh 15,709
Total kWh Sold & PH Consumption 306,337
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 73 of 181
Iliamna Newhalen Nondalton PCE
Utility: ILIAMNA NEWHALEN NONDALTON
Reporting Period: 07/01/12..06/30/13
Community Population 477
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 212
Community Facility Customers 13
Other Customers (Non-PCE)103
Fiscal Year PCE Payments $170,515
PCE Statistical Data
PCE Eligible kWh - Residential Customers 598,274 Average Annual PCE Payment per Eligible
Customer
$758
PCE Eligible kWh - Community Facility
Customers
296,178 Average PCE Payment per Eligible kWh $0.19
Total PCE Eligible kWh 894,452 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.60
Average Monthly PCE Eligible kWh per
Residential Customer
235 Last Reported PCE Level (per kWh)$0.18
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,899 Effective Residential Rate (per kWh)$0.41
Average Monthly PCE Eligible Community
Facility kWh per person
52 PCE Eligible kWh vs Total kWh Sold 27.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 37,042 Fuel Used (Gallons)2,341
Non-Diesel kWh Generated 4,126,977 Fuel Cost $10,936
Purchased kWh 0 Average Price of Fuel $4.67
Total Purchased & Generated 4,164,019 Fuel Cost per kWh sold $0.00
Annual Non-Fuel Expenses $1,073,967
Non-Fuel Expense per kWh sold $0.32
Total Expense per kWh sold $0.33
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 854,232 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
79.4%
Community Facility kWh Sold 296,992 Line Loss (%)14.4%
Other kWh Sold (Non-PCE)2,154,991 Fuel Efficiency (kWh per gallon of diesel)15.82
Total kWh Sold 3,306,215 PH Consumption as % of generation 6.2%
Powerhouse (PH) Consumption kWh 259,056
Total kWh Sold & PH Consumption 3,565,271
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 74 of 181
Kake PCE
Utility: INSIDE PASSAGE ELECTRIC
Reporting Period: 07/01/12..06/30/13
Community Population 579
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 236
Community Facility Customers 15
Other Customers (Non-PCE)55
Fiscal Year PCE Payments $485,361
PCE Statistical Data
PCE Eligible kWh - Residential Customers 905,211 Average Annual PCE Payment per Eligible
Customer
$1,934
PCE Eligible kWh - Community Facility
Customers
230,706 Average PCE Payment per Eligible kWh $0.43
Total PCE Eligible kWh 1,135,917 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.68
Average Monthly PCE Eligible kWh per
Residential Customer
320 Last Reported PCE Level (per kWh)$0.46
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,282 Effective Residential Rate (per kWh)$0.23
Average Monthly PCE Eligible Community
Facility kWh per person
33 PCE Eligible kWh vs Total kWh Sold 42.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,952,396 Fuel Used (Gallons)205,961
Non-Diesel kWh Generated 0 Fuel Cost $862,556
Purchased kWh 0 Average Price of Fuel $4.19
Total Purchased & Generated 2,952,396 Fuel Cost per kWh sold $0.32
Annual Non-Fuel Expenses $601,564
Non-Fuel Expense per kWh sold $0.23
Total Expense per kWh sold $0.55
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,090,708 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
90.5%
Community Facility kWh Sold 235,011 Line Loss (%)8.3%
Other kWh Sold (Non-PCE)1,346,313 Fuel Efficiency (kWh per gallon of diesel)14.33
Total kWh Sold 2,672,032 PH Consumption as % of generation 1.2%
Powerhouse (PH) Consumption kWh 36,500
Total kWh Sold & PH Consumption 2,708,532
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 75 of 181
Kaktovik PCE
Utility: NORTH SLOPE BOROUGH
Reporting Period: 07/01/12..06/30/13
Community Population 247
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 76
Community Facility Customers 4
Other Customers (Non-PCE)58
Fiscal Year PCE Payments $14,877
PCE Statistical Data
PCE Eligible kWh - Residential Customers 194,791 Average Annual PCE Payment per Eligible
Customer
$186
PCE Eligible kWh - Community Facility
Customers
112,655 Average PCE Payment per Eligible kWh $0.05
Total PCE Eligible kWh 307,446 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.15
Average Monthly PCE Eligible kWh per
Residential Customer
214 Last Reported PCE Level (per kWh)$0.01
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,347 Effective Residential Rate (per kWh)$0.14
Average Monthly PCE Eligible Community
Facility kWh per person
38 PCE Eligible kWh vs Total kWh Sold 5.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 4,753,100 Fuel Used (Gallons)353,761
Non-Diesel kWh Generated 0 Fuel Cost $1,410,828
Purchased kWh 0 Average Price of Fuel $3.99
Total Purchased & Generated 4,753,100 Fuel Cost per kWh sold $0.26
Annual Non-Fuel Expenses $661,203
Non-Fuel Expense per kWh sold $0.12
Total Expense per kWh sold $0.38
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 685,740 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 112,655 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)4,726,203 Fuel Efficiency (kWh per gallon of diesel)13.44
Total kWh Sold 5,524,598 PH Consumption as % of generation 3.8%
Powerhouse (PH) Consumption kWh 179,112
Total kWh Sold & PH Consumption 5,703,710
Comments
Annual reported generation < sales
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 76 of 181
Kaltag PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 205
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 73
Community Facility Customers 10
Other Customers (Non-PCE)21
Fiscal Year PCE Payments $98,379
PCE Statistical Data
PCE Eligible kWh - Residential Customers 230,022 Average Annual PCE Payment per Eligible
Customer
$1,185
PCE Eligible kWh - Community Facility
Customers
43,862 Average PCE Payment per Eligible kWh $0.36
Total PCE Eligible kWh 273,884 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.58
Average Monthly PCE Eligible kWh per
Residential Customer
263 Last Reported PCE Level (per kWh)$0.38
Average Monthly PCE Eligible kWh per
Community Facility Customer
366 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
18 PCE Eligible kWh vs Total kWh Sold 38.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 769,404 Fuel Used (Gallons)58,770
Non-Diesel kWh Generated 6,382 Fuel Cost $213,127
Purchased kWh 0 Average Price of Fuel $3.63
Total Purchased & Generated 775,786 Fuel Cost per kWh sold $0.30
Annual Non-Fuel Expenses $195,129
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.57
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 293,444 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
91.7%
Community Facility kWh Sold 43,862 Line Loss (%)5.6%
Other kWh Sold (Non-PCE)374,307 Fuel Efficiency (kWh per gallon of diesel)13.09
Total kWh Sold 711,613 PH Consumption as % of generation 2.7%
Powerhouse (PH) Consumption kWh 20,799
Total kWh Sold & PH Consumption 732,412
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 77 of 181
Karluk PCE
Utility: ALUTIIQ POWER COMPANY
Reporting Period: 07/01/12..06/30/13
Community Population 37
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 14
Community Facility Customers 2
Other Customers (Non-PCE)14
Fiscal Year PCE Payments $38,665
PCE Statistical Data
PCE Eligible kWh - Residential Customers 69,808 Average Annual PCE Payment per Eligible
Customer
$2,417
PCE Eligible kWh - Community Facility
Customers
17,928 Average PCE Payment per Eligible kWh $0.44
Total PCE Eligible kWh 87,736 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.72
Average Monthly PCE Eligible kWh per
Residential Customer
416 Last Reported PCE Level (per kWh)$0.47
Average Monthly PCE Eligible kWh per
Community Facility Customer
747 Effective Residential Rate (per kWh)$0.25
Average Monthly PCE Eligible Community
Facility kWh per person
40 PCE Eligible kWh vs Total kWh Sold 36.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 263,781 Fuel Used (Gallons)23,759
Non-Diesel kWh Generated 0 Fuel Cost $103,734
Purchased kWh 0 Average Price of Fuel $4.37
Total Purchased & Generated 263,781 Fuel Cost per kWh sold $0.43
Annual Non-Fuel Expenses $45,521
Non-Fuel Expense per kWh sold $0.19
Total Expense per kWh sold $0.62
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 112,631 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
91.1%
Community Facility kWh Sold 17,928 Line Loss (%)7.8%
Other kWh Sold (Non-PCE)109,632 Fuel Efficiency (kWh per gallon of diesel)11.10
Total kWh Sold 240,191 PH Consumption as % of generation 1.1%
Powerhouse (PH) Consumption kWh 2,986
Total kWh Sold & PH Consumption 243,177
Comments
Aug 2012 reported gen. est. by utility; Feb reptd gen < sales
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 78 of 181
Kasigluk PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 576
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 113
Community Facility Customers 7
Other Customers (Non-PCE)31
Fiscal Year PCE Payments $242,018
PCE Statistical Data
PCE Eligible kWh - Residential Customers 544,366 Average Annual PCE Payment per Eligible
Customer
$2,017
PCE Eligible kWh - Community Facility
Customers
116,348 Average PCE Payment per Eligible kWh $0.37
Total PCE Eligible kWh 660,714 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.58
Average Monthly PCE Eligible kWh per
Residential Customer
401 Last Reported PCE Level (per kWh)$0.39
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,385 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
17 PCE Eligible kWh vs Total kWh Sold 37.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,548,852 Fuel Used (Gallons)192,362
Non-Diesel kWh Generated 603,586 Fuel Cost $804,760
Purchased kWh 0 Average Price of Fuel $4.18
Total Purchased & Generated 3,152,438 Fuel Cost per kWh sold $0.46
Annual Non-Fuel Expenses $477,768
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.74
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 694,778 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
55.3%
Community Facility kWh Sold 119,708 Line Loss (%)41.4%
Other kWh Sold (Non-PCE)927,882 Fuel Efficiency (kWh per gallon of diesel)13.25
Total kWh Sold 1,742,368 PH Consumption as % of generation 3.4%
Powerhouse (PH) Consumption kWh 105,947
Total kWh Sold & PH Consumption 1,848,315
Comments
Provides power to Nunapitchuk via intertie
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 79 of 181
Kiana PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 372
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 122
Community Facility Customers 11
Other Customers (Non-PCE)18
Fiscal Year PCE Payments $276,489
PCE Statistical Data
PCE Eligible kWh - Residential Customers 433,271 Average Annual PCE Payment per Eligible
Customer
$2,079
PCE Eligible kWh - Community Facility
Customers
206,850 Average PCE Payment per Eligible kWh $0.43
Total PCE Eligible kWh 640,121 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.64
Average Monthly PCE Eligible kWh per
Residential Customer
296 Last Reported PCE Level (per kWh)$0.45
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,567 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per person
46 PCE Eligible kWh vs Total kWh Sold 44.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,542,820 Fuel Used (Gallons)112,832
Non-Diesel kWh Generated 0 Fuel Cost $475,771
Purchased kWh 0 Average Price of Fuel $4.22
Total Purchased & Generated 1,542,820 Fuel Cost per kWh sold $0.33
Annual Non-Fuel Expenses $392,164
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.61
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 616,135 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
92.7%
Community Facility kWh Sold 206,850 Line Loss (%)5.0%
Other kWh Sold (Non-PCE)607,192 Fuel Efficiency (kWh per gallon of diesel)13.67
Total kWh Sold 1,430,177 PH Consumption as % of generation 2.3%
Powerhouse (PH) Consumption kWh 35,262
Total kWh Sold & PH Consumption 1,465,439
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 80 of 181
King Cove PCE
Utility: CITY OF KING COVE
Reporting Period: 07/01/12..06/30/13
Community Population 948
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 190
Community Facility Customers 31
Other Customers (Non-PCE)207
Fiscal Year PCE Payments $128,697
PCE Statistical Data
PCE Eligible kWh - Residential Customers 750,753 Average Annual PCE Payment per Eligible
Customer
$582
PCE Eligible kWh - Community Facility
Customers
796,320 Average PCE Payment per Eligible kWh $0.08
Total PCE Eligible kWh 1,547,073 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.30
Average Monthly PCE Eligible kWh per
Residential Customer
329 Last Reported PCE Level (per kWh)$0.08
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,141 Effective Residential Rate (per kWh)$0.22
Average Monthly PCE Eligible Community
Facility kWh per person
70 PCE Eligible kWh vs Total kWh Sold 37.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,664,715 Fuel Used (Gallons)183,731
Non-Diesel kWh Generated 2,175,700 Fuel Cost $703,201
Purchased kWh 0 Average Price of Fuel $3.83
Total Purchased & Generated 4,840,415 Fuel Cost per kWh sold $0.17
Annual Non-Fuel Expenses $52,513
Non-Fuel Expense per kWh sold $0.01
Total Expense per kWh sold $0.18
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,192,034 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
84.5%
Community Facility kWh Sold 1,027,854 Line Loss (%)13.9%
Other kWh Sold (Non-PCE)1,870,465 Fuel Efficiency (kWh per gallon of diesel)14.50
Total kWh Sold 4,090,353 PH Consumption as % of generation 1.6%
Powerhouse (PH) Consumption kWh 79,462
Total kWh Sold & PH Consumption 4,169,815
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 81 of 181
Kipnuk PCE
Utility: KIPNUK LIGHT PLANT
Reporting Period: 07/01/12..06/30/13
Community Population 663
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 163
Community Facility Customers 7
Other Customers (Non-PCE)88
Fiscal Year PCE Payments $163,907
PCE Statistical Data
PCE Eligible kWh - Residential Customers 684,486 Average Annual PCE Payment per Eligible
Customer
$964
PCE Eligible kWh - Community Facility
Customers
27,928 Average PCE Payment per Eligible kWh $0.23
Total PCE Eligible kWh 712,414 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.43
Average Monthly PCE Eligible kWh per
Residential Customer
350 Last Reported PCE Level (per kWh)$0.23
Average Monthly PCE Eligible kWh per
Community Facility Customer
332 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
4 PCE Eligible kWh vs Total kWh Sold 48.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,574,880 Fuel Used (Gallons)109,499
Non-Diesel kWh Generated 0 Fuel Cost $455,516
Purchased kWh 0 Average Price of Fuel $4.16
Total Purchased & Generated 1,574,880 Fuel Cost per kWh sold $0.31
Annual Non-Fuel Expenses $354,660
Non-Fuel Expense per kWh sold $0.24
Total Expense per kWh sold $0.55
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 819,990 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
93.8%
Community Facility kWh Sold 204,629 Line Loss (%)4.9%
Other kWh Sold (Non-PCE)452,671 Fuel Efficiency (kWh per gallon of diesel)14.38
Total kWh Sold 1,477,290 PH Consumption as % of generation 1.3%
Powerhouse (PH) Consumption kWh 20,665
Total kWh Sold & PH Consumption 1,497,955
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 82 of 181
Kivalina PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 386
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 88
Community Facility Customers 10
Other Customers (Non-PCE)14
Fiscal Year PCE Payments $225,471
PCE Statistical Data
PCE Eligible kWh - Residential Customers 372,197 Average Annual PCE Payment per Eligible
Customer
$2,301
PCE Eligible kWh - Community Facility
Customers
145,021 Average PCE Payment per Eligible kWh $0.44
Total PCE Eligible kWh 517,218 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.65
Average Monthly PCE Eligible kWh per
Residential Customer
352 Last Reported PCE Level (per kWh)$0.46
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,209 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per person
31 PCE Eligible kWh vs Total kWh Sold 42.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,285,613 Fuel Used (Gallons)94,112
Non-Diesel kWh Generated 0 Fuel Cost $392,057
Purchased kWh 0 Average Price of Fuel $4.17
Total Purchased & Generated 1,285,613 Fuel Cost per kWh sold $0.32
Annual Non-Fuel Expenses $331,049
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.60
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 492,237 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
93.9%
Community Facility kWh Sold 145,021 Line Loss (%)3.5%
Other kWh Sold (Non-PCE)570,039 Fuel Efficiency (kWh per gallon of diesel)13.66
Total kWh Sold 1,207,297 PH Consumption as % of generation 2.6%
Powerhouse (PH) Consumption kWh 33,217
Total kWh Sold & PH Consumption 1,240,514
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 83 of 181
Klawock PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/12..06/30/13
Community Population 813
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 402
Community Facility Customers 21
Other Customers (Non-PCE)119
Fiscal Year PCE Payments $144,042
PCE Statistical Data
PCE Eligible kWh - Residential Customers 1,542,396 Average Annual PCE Payment per Eligible
Customer
$341
PCE Eligible kWh - Community Facility
Customers
505,225 Average PCE Payment per Eligible kWh $0.07
Total PCE Eligible kWh 2,047,621 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.26
Average Monthly PCE Eligible kWh per
Residential Customer
320 Last Reported PCE Level (per kWh)$0.08
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,005 Effective Residential Rate (per kWh)$0.18
Average Monthly PCE Eligible Community
Facility kWh per person
52 PCE Eligible kWh vs Total kWh Sold 23.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $277,508
Non-Fuel Expense per kWh sold $0.03
Total Expense per kWh sold $0.03
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 2,381,057 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 510,830 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)5,729,011 Fuel Efficiency (kWh per gallon of diesel)N/A
Total kWh Sold 8,620,898 PH Consumption as % of generation N/A
Powerhouse (PH) Consumption kWh 33,000
Total kWh Sold & PH Consumption 8,653,898
Comments
See Craig for power generation
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 84 of 181
Klukwan PCE
Utility: INSIDE PASSAGE ELECTRIC
Reporting Period: 07/01/12..06/30/13
Community Population 98
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 49
Community Facility Customers 9
Other Customers (Non-PCE)8
Fiscal Year PCE Payments $98,677
PCE Statistical Data
PCE Eligible kWh - Residential Customers 165,142 Average Annual PCE Payment per Eligible
Customer
$1,701
PCE Eligible kWh - Community Facility
Customers
65,911 Average PCE Payment per Eligible kWh $0.43
Total PCE Eligible kWh 231,053 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.68
Average Monthly PCE Eligible kWh per
Residential Customer
281 Last Reported PCE Level (per kWh)$0.46
Average Monthly PCE Eligible kWh per
Community Facility Customer
610 Effective Residential Rate (per kWh)$0.23
Average Monthly PCE Eligible Community
Facility kWh per person
56 PCE Eligible kWh vs Total kWh Sold 69.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $121,692
Non-Fuel Expense per kWh sold $0.36
Total Expense per kWh sold $0.36
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 193,401 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 67,247 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)73,783 Fuel Efficiency (kWh per gallon of diesel)N/A
Total kWh Sold 334,431 PH Consumption as % of generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 334,431
Comments
See Chilkat Valley for power generation
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 85 of 181
Kobuk PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 148
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 41
Community Facility Customers 3
Other Customers (Non-PCE)14
Fiscal Year PCE Payments $76,664
PCE Statistical Data
PCE Eligible kWh - Residential Customers 145,419 Average Annual PCE Payment per Eligible
Customer
$1,742
PCE Eligible kWh - Community Facility
Customers
86,026 Average PCE Payment per Eligible kWh $0.33
Total PCE Eligible kWh 231,445 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.68
Average Monthly PCE Eligible kWh per
Residential Customer
296 Last Reported PCE Level (per kWh)$0.48
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,390 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per person
48 PCE Eligible kWh vs Total kWh Sold 37.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $171,197
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.27
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 221,177 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 86,630 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)316,529 Fuel Efficiency (kWh per gallon of diesel)N/A
Total kWh Sold 624,336 PH Consumption as % of generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 624,336
Comments
Receives power from Shungnak
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 86 of 181
Kokhanok PCE
Utility: KOKHANOK VILLAGE COUNCIL
Reporting Period: 07/01/12..06/30/13
Community Population 179
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 53
Community Facility Customers 9
Other Customers (Non-PCE)17
Fiscal Year PCE Payments $131,921
PCE Statistical Data
PCE Eligible kWh - Residential Customers 177,387 Average Annual PCE Payment per Eligible
Customer
$2,128
PCE Eligible kWh - Community Facility
Customers
66,400 Average PCE Payment per Eligible kWh $0.54
Total PCE Eligible kWh 243,787 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.90
Average Monthly PCE Eligible kWh per
Residential Customer
279 Last Reported PCE Level (per kWh)$0.59
Average Monthly PCE Eligible kWh per
Community Facility Customer
615 Effective Residential Rate (per kWh)$0.31
Average Monthly PCE Eligible Community
Facility kWh per person
31 PCE Eligible kWh vs Total kWh Sold 56.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 362,826 Fuel Used (Gallons)33,184
Non-Diesel kWh Generated 146,535 Fuel Cost $198,878
Purchased kWh 0 Average Price of Fuel $5.99
Total Purchased & Generated 509,361 Fuel Cost per kWh sold $0.46
Annual Non-Fuel Expenses $73,599
Non-Fuel Expense per kWh sold $0.17
Total Expense per kWh sold $0.64
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 183,561 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
84.1%
Community Facility kWh Sold 68,713 Line Loss (%)9.6%
Other kWh Sold (Non-PCE)176,244 Fuel Efficiency (kWh per gallon of diesel)10.93
Total kWh Sold 428,518 PH Consumption as % of generation 6.3%
Powerhouse (PH) Consumption kWh 32,173
Total kWh Sold & PH Consumption 460,691
Comments
Mar-Apr kWh generation est by utility due to broken meter
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 87 of 181
Koliganek PCE
Utility: NEW KOLIGANEK VILLAGE COUNCIL
Reporting Period: 07/01/12..06/30/13
Community Population 226
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 69
Community Facility Customers 10
Other Customers (Non-PCE)20
Fiscal Year PCE Payments $100,286
PCE Statistical Data
PCE Eligible kWh - Residential Customers 211,322 Average Annual PCE Payment per Eligible
Customer
$1,269
PCE Eligible kWh - Community Facility
Customers
69,620 Average PCE Payment per Eligible kWh $0.36
Total PCE Eligible kWh 280,942 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.50
Average Monthly PCE Eligible kWh per
Residential Customer
255 Last Reported PCE Level (per kWh)$0.36
Average Monthly PCE Eligible kWh per
Community Facility Customer
580 Effective Residential Rate (per kWh)$0.14
Average Monthly PCE Eligible Community
Facility kWh per person
26 PCE Eligible kWh vs Total kWh Sold 46.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 683,217 Fuel Used (Gallons)59,098
Non-Diesel kWh Generated 0 Fuel Cost $266,751
Purchased kWh 0 Average Price of Fuel $4.51
Total Purchased & Generated 683,217 Fuel Cost per kWh sold $0.44
Annual Non-Fuel Expenses $102,185
Non-Fuel Expense per kWh sold $0.17
Total Expense per kWh sold $0.61
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 252,150 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
88.1%
Community Facility kWh Sold 91,113 Line Loss (%)8.3%
Other kWh Sold (Non-PCE)258,887 Fuel Efficiency (kWh per gallon of diesel)11.56
Total kWh Sold 602,150 PH Consumption as % of generation 3.5%
Powerhouse (PH) Consumption kWh 24,090
Total kWh Sold & PH Consumption 626,240
Comments
Utility est kWh gen. due to no meter for 1 of 2 gens; NonFuel$ May-Jun Unrprtd
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 88 of 181
Kongiganak PCE
Utility: PUVURNAQ POWER COMPANY
Reporting Period: 07/01/12..06/30/13
Community Population 462
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 100
Community Facility Customers 5
Other Customers (Non-PCE)23
Fiscal Year PCE Payments $165,501
PCE Statistical Data
PCE Eligible kWh - Residential Customers 396,422 Average Annual PCE Payment per Eligible
Customer
$1,576
PCE Eligible kWh - Community Facility
Customers
78,574 Average PCE Payment per Eligible kWh $0.35
Total PCE Eligible kWh 474,996 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.65
Average Monthly PCE Eligible kWh per
Residential Customer
330 Last Reported PCE Level (per kWh)$0.35
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,310 Effective Residential Rate (per kWh)$0.30
Average Monthly PCE Eligible Community
Facility kWh per person
14 PCE Eligible kWh vs Total kWh Sold 45.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 861,659 Fuel Used (Gallons)72,956
Non-Diesel kWh Generated 318,848 Fuel Cost $327,884
Purchased kWh 126,254 Average Price of Fuel $4.49
Total Purchased & Generated 1,306,761 Fuel Cost per kWh sold $0.32
Annual Non-Fuel Expenses $341,463
Non-Fuel Expense per kWh sold $0.33
Total Expense per kWh sold $0.65
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 589,573 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
79.2%
Community Facility kWh Sold 83,345 Line Loss (%)18.2%
Other kWh Sold (Non-PCE)362,472 Fuel Efficiency (kWh per gallon of diesel)11.81
Total kWh Sold 1,035,390 PH Consumption as % of generation 2.6%
Powerhouse (PH) Consumption kWh 33,913
Total kWh Sold & PH Consumption 1,069,303
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 89 of 181
Kotlik PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 601
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 131
Community Facility Customers 12
Other Customers (Non-PCE)21
Fiscal Year PCE Payments $318,884
PCE Statistical Data
PCE Eligible kWh - Residential Customers 568,920 Average Annual PCE Payment per Eligible
Customer
$2,230
PCE Eligible kWh - Community Facility
Customers
217,875 Average PCE Payment per Eligible kWh $0.41
Total PCE Eligible kWh 786,795 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.62
Average Monthly PCE Eligible kWh per
Residential Customer
362 Last Reported PCE Level (per kWh)$0.42
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,513 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per person
30 PCE Eligible kWh vs Total kWh Sold 41.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,028,578 Fuel Used (Gallons)151,641
Non-Diesel kWh Generated 0 Fuel Cost $580,690
Purchased kWh 0 Average Price of Fuel $3.83
Total Purchased & Generated 2,028,578 Fuel Cost per kWh sold $0.31
Annual Non-Fuel Expenses $518,555
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.58
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 783,602 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
93.2%
Community Facility kWh Sold 217,875 Line Loss (%)4.3%
Other kWh Sold (Non-PCE)889,634 Fuel Efficiency (kWh per gallon of diesel)13.38
Total kWh Sold 1,891,111 PH Consumption as % of generation 2.5%
Powerhouse (PH) Consumption kWh 50,800
Total kWh Sold & PH Consumption 1,941,911
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 90 of 181
Kotzebue PCE
Utility: KOTZEBUE ELECTRIC ASSOCIATION
Reporting Period: 07/01/12..06/30/13
Community Population 3224
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 1,046
Community Facility Customers 29
Other Customers (Non-PCE)171
Fiscal Year PCE Payments $1,438,921
PCE Statistical Data
PCE Eligible kWh - Residential Customers 3,843,265 Average Annual PCE Payment per Eligible
Customer
$1,339
PCE Eligible kWh - Community Facility
Customers
1,718,367 Average PCE Payment per Eligible kWh $0.26
Total PCE Eligible kWh 5,561,632 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.40
Average Monthly PCE Eligible kWh per
Residential Customer
306 Last Reported PCE Level (per kWh)$0.25
Average Monthly PCE Eligible kWh per
Community Facility Customer
4,938 Effective Residential Rate (per kWh)$0.15
Average Monthly PCE Eligible Community
Facility kWh per person
44 PCE Eligible kWh vs Total kWh Sold 26.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 18,396,423 Fuel Used (Gallons)1,275,202
Non-Diesel kWh Generated 4,155,486 Fuel Cost $4,462,361
Purchased kWh 0 Average Price of Fuel $3.50
Total Purchased & Generated 22,551,909 Fuel Cost per kWh sold $0.22
Annual Non-Fuel Expenses $2,774,422
Non-Fuel Expense per kWh sold $0.13
Total Expense per kWh sold $0.35
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 7,370,490 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
92.0%
Community Facility kWh Sold 1,737,330 Line Loss (%)5.9%
Other kWh Sold (Non-PCE)11,629,987 Fuel Efficiency (kWh per gallon of diesel)14.43
Total kWh Sold 20,737,807 PH Consumption as % of generation 2.2%
Powerhouse (PH) Consumption kWh 486,278
Total kWh Sold & PH Consumption 21,224,085
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 91 of 181
Koyuk PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 347
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 91
Community Facility Customers 12
Other Customers (Non-PCE)26
Fiscal Year PCE Payments $210,181
PCE Statistical Data
PCE Eligible kWh - Residential Customers 352,186 Average Annual PCE Payment per Eligible
Customer
$2,041
PCE Eligible kWh - Community Facility
Customers
199,899 Average PCE Payment per Eligible kWh $0.38
Total PCE Eligible kWh 552,085 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.60
Average Monthly PCE Eligible kWh per
Residential Customer
323 Last Reported PCE Level (per kWh)$0.41
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,388 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
48 PCE Eligible kWh vs Total kWh Sold 43.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,324,386 Fuel Used (Gallons)96,891
Non-Diesel kWh Generated 0 Fuel Cost $380,496
Purchased kWh 0 Average Price of Fuel $3.93
Total Purchased & Generated 1,324,386 Fuel Cost per kWh sold $0.30
Annual Non-Fuel Expenses $347,383
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.57
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 499,945 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
95.7%
Community Facility kWh Sold 199,899 Line Loss (%)3.1%
Other kWh Sold (Non-PCE)567,023 Fuel Efficiency (kWh per gallon of diesel)13.67
Total kWh Sold 1,266,867 PH Consumption as % of generation 1.2%
Powerhouse (PH) Consumption kWh 15,804
Total kWh Sold & PH Consumption 1,282,671
Comments
Sep, May reported generation < sales
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 92 of 181
Koyukuk PCE
Utility: CITY OF KOYUKUK
Reporting Period: 07/01/12..06/30/13
Community Population 97
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 58
Community Facility Customers 5
Other Customers (Non-PCE)11
Fiscal Year PCE Payments $39,307
PCE Statistical Data
PCE Eligible kWh - Residential Customers 84,941 Average Annual PCE Payment per Eligible
Customer
$624
PCE Eligible kWh - Community Facility
Customers
13,197 Average PCE Payment per Eligible kWh $0.40
Total PCE Eligible kWh 98,138 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.95
Average Monthly PCE Eligible kWh per
Residential Customer
122 Last Reported PCE Level (per kWh)$0.41
Average Monthly PCE Eligible kWh per
Community Facility Customer
220 Effective Residential Rate (per kWh)$0.54
Average Monthly PCE Eligible Community
Facility kWh per person
11 PCE Eligible kWh vs Total kWh Sold 40.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 299,407 Fuel Used (Gallons)31,000
Non-Diesel kWh Generated 0 Fuel Cost $129,928
Purchased kWh 0 Average Price of Fuel $4.19
Total Purchased & Generated 299,407 Fuel Cost per kWh sold $0.54
Annual Non-Fuel Expenses $29,735
Non-Fuel Expense per kWh sold $0.12
Total Expense per kWh sold $0.67
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 86,454 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
80.1%
Community Facility kWh Sold 66,018 Line Loss (%)19.9%
Other kWh Sold (Non-PCE)87,485 Fuel Efficiency (kWh per gallon of diesel)9.66
Total kWh Sold 239,957 PH Consumption as % of generation 0.0%
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 239,957
Comments
Powerhouse use not reported; Sep,Oct irregular reporting periods
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 93 of 181
Kwethluk PCE
Utility: KWETHLUK INCORPORATED
Reporting Period: 07/01/12..06/30/13
Community Population 741
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 180
Community Facility Customers 4
Other Customers (Non-PCE)36
Fiscal Year PCE Payments $183,946
PCE Statistical Data
PCE Eligible kWh - Residential Customers 543,041 Average Annual PCE Payment per Eligible
Customer
$1,000
PCE Eligible kWh - Community Facility
Customers
38,323 Average PCE Payment per Eligible kWh $0.32
Total PCE Eligible kWh 581,364 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.52
Average Monthly PCE Eligible kWh per
Residential Customer
251 Last Reported PCE Level (per kWh)$0.32
Average Monthly PCE Eligible kWh per
Community Facility Customer
798 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per person
4 PCE Eligible kWh vs Total kWh Sold 46.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,483,190 Fuel Used (Gallons)108,472
Non-Diesel kWh Generated 0 Fuel Cost $473,841
Purchased kWh 0 Average Price of Fuel $4.37
Total Purchased & Generated 1,483,190 Fuel Cost per kWh sold $0.38
Annual Non-Fuel Expenses $128,320
Non-Fuel Expense per kWh sold $0.10
Total Expense per kWh sold $0.48
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 693,535 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
84.2%
Community Facility kWh Sold 38,323 Line Loss (%)12.8%
Other kWh Sold (Non-PCE)516,359 Fuel Efficiency (kWh per gallon of diesel)13.67
Total kWh Sold 1,248,217 PH Consumption as % of generation 3.1%
Powerhouse (PH) Consumption kWh 45,292
Total kWh Sold & PH Consumption 1,293,509
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 94 of 181
Kwigillingok PCE
Utility: KWIGILLINGOK IRA COUNCIL
Reporting Period: 07/01/12..06/30/13
Community Population 342
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 96
Community Facility Customers 3
Other Customers (Non-PCE)31
Fiscal Year PCE Payments $202,597
PCE Statistical Data
PCE Eligible kWh - Residential Customers 383,962 Average Annual PCE Payment per Eligible
Customer
$2,046
PCE Eligible kWh - Community Facility
Customers
88,697 Average PCE Payment per Eligible kWh $0.43
Total PCE Eligible kWh 472,659 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.61
Average Monthly PCE Eligible kWh per
Residential Customer
333 Last Reported PCE Level (per kWh)$0.41
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,464 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per person
22 PCE Eligible kWh vs Total kWh Sold 45.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,125,730 Fuel Used (Gallons)85,324
Non-Diesel kWh Generated 59,295 Fuel Cost $381,067
Purchased kWh 0 Average Price of Fuel $4.47
Total Purchased & Generated 1,185,025 Fuel Cost per kWh sold $0.37
Annual Non-Fuel Expenses $344,893
Non-Fuel Expense per kWh sold $0.34
Total Expense per kWh sold $0.71
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 484,963 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
86.8%
Community Facility kWh Sold 106,805 Line Loss (%)8.4%
Other kWh Sold (Non-PCE)437,000 Fuel Efficiency (kWh per gallon of diesel)13.19
Total kWh Sold 1,028,768 PH Consumption as % of generation 4.8%
Powerhouse (PH) Consumption kWh 57,260
Total kWh Sold & PH Consumption 1,086,028
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 95 of 181
Larsen Bay PCE
Utility: LARSEN BAY UTILITY COMPANY
Reporting Period: 07/01/12..06/30/13
Community Population 89
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 52
Community Facility Customers 8
Other Customers (Non-PCE)41
Fiscal Year PCE Payments $10,576
PCE Statistical Data
PCE Eligible kWh - Residential Customers 119,748 Average Annual PCE Payment per Eligible
Customer
$176
PCE Eligible kWh - Community Facility
Customers
53,200 Average PCE Payment per Eligible kWh $0.06
Total PCE Eligible kWh 172,948 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.44
Average Monthly PCE Eligible kWh per
Residential Customer
192 Last Reported PCE Level (per kWh)$0.06
Average Monthly PCE Eligible kWh per
Community Facility Customer
554 Effective Residential Rate (per kWh)$0.38
Average Monthly PCE Eligible Community
Facility kWh per person
50 PCE Eligible kWh vs Total kWh Sold 23.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 22,672 Fuel Used (Gallons)2,245
Non-Diesel kWh Generated 807,425 Fuel Cost $9,999
Purchased kWh 0 Average Price of Fuel $4.45
Total Purchased & Generated 830,097 Fuel Cost per kWh sold $0.01
Annual Non-Fuel Expenses $17,289
Non-Fuel Expense per kWh sold $0.02
Total Expense per kWh sold $0.04
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 169,763 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
90.1%
Community Facility kWh Sold 125,930 Line Loss (%)7.4%
Other kWh Sold (Non-PCE)452,156 Fuel Efficiency (kWh per gallon of diesel)10.10
Total kWh Sold 747,849 PH Consumption as % of generation 2.5%
Powerhouse (PH) Consumption kWh 20,791
Total kWh Sold & PH Consumption 768,640
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 96 of 181
Levelock PCE
Utility: LEVELOCK ELECTRICAL COOP
Reporting Period: 07/01/12..06/30/13
Community Population 81
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 33
Community Facility Customers 7
Other Customers (Non-PCE)24
Fiscal Year PCE Payments $61,365
PCE Statistical Data
PCE Eligible kWh - Residential Customers 100,381 Average Annual PCE Payment per Eligible
Customer
$1,534
PCE Eligible kWh - Community Facility
Customers
25,856 Average PCE Payment per Eligible kWh $0.49
Total PCE Eligible kWh 126,237 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.70
Average Monthly PCE Eligible kWh per
Residential Customer
253 Last Reported PCE Level (per kWh)$0.49
Average Monthly PCE Eligible kWh per
Community Facility Customer
308 Effective Residential Rate (per kWh)$0.21
Average Monthly PCE Eligible Community
Facility kWh per person
27 PCE Eligible kWh vs Total kWh Sold 38.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 456,881 Fuel Used (Gallons)43,436
Non-Diesel kWh Generated 0 Fuel Cost $171,976
Purchased kWh 0 Average Price of Fuel $3.96
Total Purchased & Generated 456,881 Fuel Cost per kWh sold $0.53
Annual Non-Fuel Expenses $126,428
Non-Fuel Expense per kWh sold $0.39
Total Expense per kWh sold $0.91
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 117,121 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
71.5%
Community Facility kWh Sold 39,640 Line Loss (%)18.2%
Other kWh Sold (Non-PCE)170,029 Fuel Efficiency (kWh per gallon of diesel)10.52
Total kWh Sold 326,790 PH Consumption as % of generation 10.3%
Powerhouse (PH) Consumption kWh 46,941
Total kWh Sold & PH Consumption 373,731
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 97 of 181
Lime Village PCE
Utility: LIME VILLAGE ELECTRIC UTILITY
Reporting Period: 07/01/12..06/30/13
Community Population 29
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 17
Community Facility Customers 5
Other Customers (Non-PCE)3
Fiscal Year PCE Payments $22,397
PCE Statistical Data
PCE Eligible kWh - Residential Customers 15,112 Average Annual PCE Payment per Eligible
Customer
$1,018
PCE Eligible kWh - Community Facility
Customers
12,333 Average PCE Payment per Eligible kWh $0.82
Total PCE Eligible kWh 27,445 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.77
Average Monthly PCE Eligible kWh per
Residential Customer
74 Last Reported PCE Level (per kWh)$0.81
Average Monthly PCE Eligible kWh per
Community Facility Customer
206 Effective Residential Rate (per kWh)$0.96
Average Monthly PCE Eligible Community
Facility kWh per person
35 PCE Eligible kWh vs Total kWh Sold 51.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 74,896 Fuel Used (Gallons)7,720
Non-Diesel kWh Generated 0 Fuel Cost $59,543
Purchased kWh 0 Average Price of Fuel $7.71
Total Purchased & Generated 74,896 Fuel Cost per kWh sold $1.11
Annual Non-Fuel Expenses $56,516
Non-Fuel Expense per kWh sold $1.05
Total Expense per kWh sold $2.16
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 17,633 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
71.8%
Community Facility kWh Sold 12,438 Line Loss (%)23.7%
Other kWh Sold (Non-PCE)23,719 Fuel Efficiency (kWh per gallon of diesel)9.70
Total kWh Sold 53,790 PH Consumption as % of generation 4.5%
Powerhouse (PH) Consumption kWh 3,347
Total kWh Sold & PH Consumption 57,137
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 98 of 181
Lower Kalskag PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 287
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 85
Community Facility Customers 7
Other Customers (Non-PCE)5
Fiscal Year PCE Payments $136,849
PCE Statistical Data
PCE Eligible kWh - Residential Customers 251,701 Average Annual PCE Payment per Eligible
Customer
$1,487
PCE Eligible kWh - Community Facility
Customers
91,210 Average PCE Payment per Eligible kWh $0.40
Total PCE Eligible kWh 342,911 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.61
Average Monthly PCE Eligible kWh per
Residential Customer
247 Last Reported PCE Level (per kWh)$0.42
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,086 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per person
26 PCE Eligible kWh vs Total kWh Sold 69.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $134,869
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.27
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 279,819 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 91,210 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)120,823 Fuel Efficiency (kWh per gallon of diesel)N/A
Total kWh Sold 491,852 PH Consumption as % of generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 491,852
Comments
Power is from Upper Kalskag via intertie. See Upper Kalskag for fuel cost.
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 99 of 181
Manley Hot Springs PCE
Utility: TDX MANLEY GENERATING LLC
Reporting Period: 07/01/12..06/30/13
Community Population 91
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 90
Community Facility Customers 3
Other Customers (Non-PCE)17
Fiscal Year PCE Payments $96,761
PCE Statistical Data
PCE Eligible kWh - Residential Customers 158,320 Average Annual PCE Payment per Eligible
Customer
$1,040
PCE Eligible kWh - Community Facility
Customers
5,411 Average PCE Payment per Eligible kWh $0.59
Total PCE Eligible kWh 163,731 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.97
Average Monthly PCE Eligible kWh per
Residential Customer
147 Last Reported PCE Level (per kWh)$0.67
Average Monthly PCE Eligible kWh per
Community Facility Customer
150 Effective Residential Rate (per kWh)$0.29
Average Monthly PCE Eligible Community
Facility kWh per person
5 PCE Eligible kWh vs Total kWh Sold 40.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 462,269 Fuel Used (Gallons)37,399
Non-Diesel kWh Generated 0 Fuel Cost $150,040
Purchased kWh 0 Average Price of Fuel $4.01
Total Purchased & Generated 462,269 Fuel Cost per kWh sold $0.37
Annual Non-Fuel Expenses $213,714
Non-Fuel Expense per kWh sold $0.53
Total Expense per kWh sold $0.91
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 202,902 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
86.8%
Community Facility kWh Sold 5,411 Line Loss (%)10.7%
Other kWh Sold (Non-PCE)192,837 Fuel Efficiency (kWh per gallon of diesel)12.36
Total kWh Sold 401,150 PH Consumption as % of generation 2.6%
Powerhouse (PH) Consumption kWh 11,824
Total kWh Sold & PH Consumption 412,974
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 100 of 181
Manokotak PCE
Utility: MANOKOTAK POWER COMPANY
Reporting Period: 07/01/12..06/30/13
Community Population 450
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 141
Community Facility Customers 5
Other Customers (Non-PCE)48
Fiscal Year PCE Payments $114,669
PCE Statistical Data
PCE Eligible kWh - Residential Customers 440,902 Average Annual PCE Payment per Eligible
Customer
$785
PCE Eligible kWh - Community Facility
Customers
8,037 Average PCE Payment per Eligible kWh $0.26
Total PCE Eligible kWh 448,939 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.55
Average Monthly PCE Eligible kWh per
Residential Customer
261 Last Reported PCE Level (per kWh)$0.27
Average Monthly PCE Eligible kWh per
Community Facility Customer
134 Effective Residential Rate (per kWh)$0.28
Average Monthly PCE Eligible Community
Facility kWh per person
1 PCE Eligible kWh vs Total kWh Sold 35.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)109,352
Non-Diesel kWh Generated 0 Fuel Cost $439,668
Purchased kWh 0 Average Price of Fuel $4.02
Total Purchased & Generated 0 Fuel Cost per kWh sold $0.35
Annual Non-Fuel Expenses $27,431
Non-Fuel Expense per kWh sold $0.02
Total Expense per kWh sold $0.37
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 531,356 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 76,054 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)648,905 Fuel Efficiency (kWh per gallon of diesel)N/A
Total kWh Sold 1,256,315 PH Consumption as % of generation N/A
Powerhouse (PH) Consumption kWh 66,832
Total kWh Sold & PH Consumption 1,323,147
Comments
kWh generated not reported due to failing meter sceens. Screens replaced Oct 13.
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 101 of 181
Marshall PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 407
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 113
Community Facility Customers 15
Other Customers (Non-PCE)24
Fiscal Year PCE Payments $248,595
PCE Statistical Data
PCE Eligible kWh - Residential Customers 460,054 Average Annual PCE Payment per Eligible
Customer
$1,942
PCE Eligible kWh - Community Facility
Customers
219,778 Average PCE Payment per Eligible kWh $0.37
Total PCE Eligible kWh 679,832 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.59
Average Monthly PCE Eligible kWh per
Residential Customer
339 Last Reported PCE Level (per kWh)$0.39
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,221 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
45 PCE Eligible kWh vs Total kWh Sold 42.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,687,602 Fuel Used (Gallons)131,656
Non-Diesel kWh Generated 0 Fuel Cost $477,979
Purchased kWh 0 Average Price of Fuel $3.63
Total Purchased & Generated 1,687,602 Fuel Cost per kWh sold $0.30
Annual Non-Fuel Expenses $438,179
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.57
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 590,828 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
94.7%
Community Facility kWh Sold 211,618 Line Loss (%)3.1%
Other kWh Sold (Non-PCE)795,543 Fuel Efficiency (kWh per gallon of diesel)12.82
Total kWh Sold 1,597,989 PH Consumption as % of generation 2.2%
Powerhouse (PH) Consumption kWh 36,608
Total kWh Sold & PH Consumption 1,634,597
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 102 of 181
McGrath PCE
Utility: MCGRATH LIGHT & POWER
Reporting Period: 07/01/12..06/30/13
Community Population 341
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 186
Community Facility Customers 15
Other Customers (Non-PCE)95
Fiscal Year PCE Payments $337,304
PCE Statistical Data
PCE Eligible kWh - Residential Customers 562,767 Average Annual PCE Payment per Eligible
Customer
$1,678
PCE Eligible kWh - Community Facility
Customers
265,817 Average PCE Payment per Eligible kWh $0.41
Total PCE Eligible kWh 828,584 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.73
Average Monthly PCE Eligible kWh per
Residential Customer
252 Last Reported PCE Level (per kWh)$0.41
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,477 Effective Residential Rate (per kWh)$0.32
Average Monthly PCE Eligible Community
Facility kWh per person
65 PCE Eligible kWh vs Total kWh Sold 33.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,754,364 Fuel Used (Gallons)191,784
Non-Diesel kWh Generated 0 Fuel Cost $862,768
Purchased kWh 0 Average Price of Fuel $4.50
Total Purchased & Generated 2,754,364 Fuel Cost per kWh sold $0.35
Annual Non-Fuel Expenses $945,595
Non-Fuel Expense per kWh sold $0.38
Total Expense per kWh sold $0.73
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 679,128 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
90.1%
Community Facility kWh Sold 275,174 Line Loss (%)7.1%
Other kWh Sold (Non-PCE)1,526,397 Fuel Efficiency (kWh per gallon of diesel)14.36
Total kWh Sold 2,480,699 PH Consumption as % of generation 2.8%
Powerhouse (PH) Consumption kWh 78,114
Total kWh Sold & PH Consumption 2,558,813
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 103 of 181
Mekoryuk PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 215
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 91
Community Facility Customers 10
Other Customers (Non-PCE)27
Fiscal Year PCE Payments $142,655
PCE Statistical Data
PCE Eligible kWh - Residential Customers 278,154 Average Annual PCE Payment per Eligible
Customer
$1,412
PCE Eligible kWh - Community Facility
Customers
151,370 Average PCE Payment per Eligible kWh $0.33
Total PCE Eligible kWh 429,524 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.55
Average Monthly PCE Eligible kWh per
Residential Customer
255 Last Reported PCE Level (per kWh)$0.36
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,261 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
59 PCE Eligible kWh vs Total kWh Sold 47.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 825,971 Fuel Used (Gallons)61,864
Non-Diesel kWh Generated 186,660 Fuel Cost $232,495
Purchased kWh 0 Average Price of Fuel $3.76
Total Purchased & Generated 1,012,631 Fuel Cost per kWh sold $0.26
Annual Non-Fuel Expenses $245,853
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.53
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 305,522 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
88.5%
Community Facility kWh Sold 198,353 Line Loss (%)5.6%
Other kWh Sold (Non-PCE)392,725 Fuel Efficiency (kWh per gallon of diesel)13.35
Total kWh Sold 896,600 PH Consumption as % of generation 5.9%
Powerhouse (PH) Consumption kWh 59,563
Total kWh Sold & PH Consumption 956,163
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 104 of 181
Mentasta PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/12..06/30/13
Community Population 126
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 51
Community Facility Customers 5
Other Customers (Non-PCE)15
Fiscal Year PCE Payments $79,951
PCE Statistical Data
PCE Eligible kWh - Residential Customers 147,056 Average Annual PCE Payment per Eligible
Customer
$1,428
PCE Eligible kWh - Community Facility
Customers
23,267 Average PCE Payment per Eligible kWh $0.47
Total PCE Eligible kWh 170,323 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.69
Average Monthly PCE Eligible kWh per
Residential Customer
240 Last Reported PCE Level (per kWh)$0.42
Average Monthly PCE Eligible kWh per
Community Facility Customer
388 Effective Residential Rate (per kWh)$0.27
Average Monthly PCE Eligible Community
Facility kWh per person
15 PCE Eligible kWh vs Total kWh Sold 47.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $36,424
Non-Fuel Expense per kWh sold $0.10
Total Expense per kWh sold $0.10
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 157,505 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 23,267 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)179,230 Fuel Efficiency (kWh per gallon of diesel)N/A
Total kWh Sold 360,002 PH Consumption as % of generation N/A
Powerhouse (PH) Consumption kWh 203
Total kWh Sold & PH Consumption 360,205
Comments
See Slana; became part of the Slana-Chistochina grid Aug 11
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 105 of 181
Minto PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 209
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 74
Community Facility Customers 5
Other Customers (Non-PCE)16
Fiscal Year PCE Payments $147,247
PCE Statistical Data
PCE Eligible kWh - Residential Customers 231,741 Average Annual PCE Payment per Eligible
Customer
$1,864
PCE Eligible kWh - Community Facility
Customers
140,415 Average PCE Payment per Eligible kWh $0.40
Total PCE Eligible kWh 372,156 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.61
Average Monthly PCE Eligible kWh per
Residential Customer
261 Last Reported PCE Level (per kWh)$0.41
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,340 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
56 PCE Eligible kWh vs Total kWh Sold 62.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 634,546 Fuel Used (Gallons)48,730
Non-Diesel kWh Generated 0 Fuel Cost $178,692
Purchased kWh 0 Average Price of Fuel $3.67
Total Purchased & Generated 634,546 Fuel Cost per kWh sold $0.30
Annual Non-Fuel Expenses $163,129
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.57
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 281,107 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
93.8%
Community Facility kWh Sold 143,237 Line Loss (%)4.2%
Other kWh Sold (Non-PCE)170,570 Fuel Efficiency (kWh per gallon of diesel)13.02
Total kWh Sold 594,914 PH Consumption as % of generation 2.0%
Powerhouse (PH) Consumption kWh 12,911
Total kWh Sold & PH Consumption 607,825
Comments
Sep,Nov,Mar reported generation < sales
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 106 of 181
Mt. Village PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 835
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 194
Community Facility Customers 19
Other Customers (Non-PCE)30
Fiscal Year PCE Payments $443,272
PCE Statistical Data
PCE Eligible kWh - Residential Customers 755,579 Average Annual PCE Payment per Eligible
Customer
$2,081
PCE Eligible kWh - Community Facility
Customers
400,720 Average PCE Payment per Eligible kWh $0.38
Total PCE Eligible kWh 1,156,299 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.60
Average Monthly PCE Eligible kWh per
Residential Customer
325 Last Reported PCE Level (per kWh)$0.40
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,758 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
40 PCE Eligible kWh vs Total kWh Sold 41.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,983,169 Fuel Used (Gallons)231,402
Non-Diesel kWh Generated 0 Fuel Cost $892,712
Purchased kWh 0 Average Price of Fuel $3.86
Total Purchased & Generated 2,983,169 Fuel Cost per kWh sold $0.32
Annual Non-Fuel Expenses $769,745
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.59
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,080,225 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
94.1%
Community Facility kWh Sold 390,640 Line Loss (%)4.2%
Other kWh Sold (Non-PCE)1,336,310 Fuel Efficiency (kWh per gallon of diesel)12.89
Total kWh Sold 2,807,175 PH Consumption as % of generation 1.7%
Powerhouse (PH) Consumption kWh 49,268
Total kWh Sold & PH Consumption 2,856,443
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 107 of 181
Naknek;S.Naknek;Kng Slmn PCE
Utility: NAKNEK ELECTRIC
Reporting Period: 07/01/12..06/30/13
Community Population 1035
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 808
Community Facility Customers 40
Other Customers (Non-PCE)358
Fiscal Year PCE Payments $1,048,271
PCE Statistical Data
PCE Eligible kWh - Residential Customers 1,969,096 Average Annual PCE Payment per Eligible
Customer
$1,236
PCE Eligible kWh - Community Facility
Customers
832,602 Average PCE Payment per Eligible kWh $0.37
Total PCE Eligible kWh 2,801,698 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.59
Average Monthly PCE Eligible kWh per
Residential Customer
203 Last Reported PCE Level (per kWh)$0.40
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,735 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
67 PCE Eligible kWh vs Total kWh Sold 15.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 20,740,023 Fuel Used (Gallons)1,354,015
Non-Diesel kWh Generated 0 Fuel Cost $4,889,720
Purchased kWh 0 Average Price of Fuel $3.61
Total Purchased & Generated 20,740,023 Fuel Cost per kWh sold $0.26
Annual Non-Fuel Expenses $3,583,297
Non-Fuel Expense per kWh sold $0.19
Total Expense per kWh sold $0.46
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 2,729,053 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
89.6%
Community Facility kWh Sold 1,562,240 Line Loss (%)7.4%
Other kWh Sold (Non-PCE)14,293,371 Fuel Efficiency (kWh per gallon of diesel)15.32
Total kWh Sold 18,584,664 PH Consumption as % of generation 3.0%
Powerhouse (PH) Consumption kWh 627,523
Total kWh Sold & PH Consumption 19,212,187
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 108 of 181
Napakiak PCE
Utility: NAPAKIAK IRCINRAQ
Reporting Period: 07/01/12..06/30/13
Community Population 359
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 111
Community Facility Customers 3
Other Customers (Non-PCE)27
Fiscal Year PCE Payments $209,309
PCE Statistical Data
PCE Eligible kWh - Residential Customers 341,689 Average Annual PCE Payment per Eligible
Customer
$1,836
PCE Eligible kWh - Community Facility
Customers
29,081 Average PCE Payment per Eligible kWh $0.56
Total PCE Eligible kWh 370,770 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.84
Average Monthly PCE Eligible kWh per
Residential Customer
257 Last Reported PCE Level (per kWh)$0.60
Average Monthly PCE Eligible kWh per
Community Facility Customer
808 Effective Residential Rate (per kWh)$0.24
Average Monthly PCE Eligible Community
Facility kWh per person
7 PCE Eligible kWh vs Total kWh Sold 65.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 619,200 Average Price of Fuel $0.00
Total Purchased & Generated 619,200 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $150,111
Non-Fuel Expense per kWh sold $0.26
Total Expense per kWh sold $0.26
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 349,462 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
91.5%
Community Facility kWh Sold 29,081 Line Loss (%)8.2%
Other kWh Sold (Non-PCE)188,058 Fuel Efficiency (kWh per gallon of diesel)N/A
Total kWh Sold 566,601 PH Consumption as % of generation 0.3%
Powerhouse (PH) Consumption kWh 2,022
Total kWh Sold & PH Consumption 568,623
Comments
Power is purchased from Bethel Utilities Corp.
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 109 of 181
Napaskiak PCE
Utility: NAPASKIAK ELECTRIC UTILITY
Reporting Period: 07/01/12..06/30/13
Community Population 428
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 109
Community Facility Customers 8
Other Customers (Non-PCE)30
Fiscal Year PCE Payments $157,522
PCE Statistical Data
PCE Eligible kWh - Residential Customers 367,443 Average Annual PCE Payment per Eligible
Customer
$1,346
PCE Eligible kWh - Community Facility
Customers
33,315 Average PCE Payment per Eligible kWh $0.39
Total PCE Eligible kWh 400,758 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.70
Average Monthly PCE Eligible kWh per
Residential Customer
281 Last Reported PCE Level (per kWh)$0.39
Average Monthly PCE Eligible kWh per
Community Facility Customer
347 Effective Residential Rate (per kWh)$0.31
Average Monthly PCE Eligible Community
Facility kWh per person
6 PCE Eligible kWh vs Total kWh Sold 57.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 992,964 Fuel Used (Gallons)69,767
Non-Diesel kWh Generated 0 Fuel Cost $309,347
Purchased kWh 0 Average Price of Fuel $4.43
Total Purchased & Generated 992,964 Fuel Cost per kWh sold $0.44
Annual Non-Fuel Expenses $165,380
Non-Fuel Expense per kWh sold $0.24
Total Expense per kWh sold $0.68
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 401,211 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
70.4%
Community Facility kWh Sold 62,079 Line Loss (%)24.7%
Other kWh Sold (Non-PCE)235,723 Fuel Efficiency (kWh per gallon of diesel)14.23
Total kWh Sold 699,013 PH Consumption as % of generation 4.9%
Powerhouse (PH) Consumption kWh 48,824
Total kWh Sold & PH Consumption 747,837
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 110 of 181
Naukati PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/12..06/30/13
Community Population 117
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 60
Community Facility Customers 0
Other Customers (Non-PCE)12
Fiscal Year PCE Payments $83,484
PCE Statistical Data
PCE Eligible kWh - Residential Customers 211,239 Average Annual PCE Payment per Eligible
Customer
$1,391
PCE Eligible kWh - Community Facility
Customers
0 Average PCE Payment per Eligible kWh $0.40
Total PCE Eligible kWh 211,239 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.58
Average Monthly PCE Eligible kWh per
Residential Customer
293 Last Reported PCE Level (per kWh)$0.36
Average Monthly PCE Eligible kWh per
Community Facility Customer
0 Effective Residential Rate (per kWh)$0.21
Average Monthly PCE Eligible Community
Facility kWh per person
0 PCE Eligible kWh vs Total kWh Sold 54.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 419,884 Fuel Used (Gallons)34,890
Non-Diesel kWh Generated 0 Fuel Cost $136,826
Purchased kWh 0 Average Price of Fuel $3.92
Total Purchased & Generated 419,884 Fuel Cost per kWh sold $0.35
Annual Non-Fuel Expenses $51,157
Non-Fuel Expense per kWh sold $0.13
Total Expense per kWh sold $0.48
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 266,357 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
92.4%
Community Facility kWh Sold 0 Line Loss (%)5.6%
Other kWh Sold (Non-PCE)121,730 Fuel Efficiency (kWh per gallon of diesel)12.03
Total kWh Sold 388,087 PH Consumption as % of generation 1.9%
Powerhouse (PH) Consumption kWh 8,160
Total kWh Sold & PH Consumption 396,247
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 111 of 181
Nelson Lagoon PCE
Utility: NELSON LAGOON ELECTRICAL COOP
Reporting Period: 07/01/12..06/30/13
Community Population 45
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 31
Community Facility Customers 5
Other Customers (Non-PCE)21
Fiscal Year PCE Payments $62,915
PCE Statistical Data
PCE Eligible kWh - Residential Customers 97,588 Average Annual PCE Payment per Eligible
Customer
$1,748
PCE Eligible kWh - Community Facility
Customers
30,667 Average PCE Payment per Eligible kWh $0.49
Total PCE Eligible kWh 128,255 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.84
Average Monthly PCE Eligible kWh per
Residential Customer
262 Last Reported PCE Level (per kWh)$0.49
Average Monthly PCE Eligible kWh per
Community Facility Customer
511 Effective Residential Rate (per kWh)$0.35
Average Monthly PCE Eligible Community
Facility kWh per person
57 PCE Eligible kWh vs Total kWh Sold 41.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 365,681 Fuel Used (Gallons)38,359
Non-Diesel kWh Generated 0 Fuel Cost $166,167
Purchased kWh 0 Average Price of Fuel $4.33
Total Purchased & Generated 365,681 Fuel Cost per kWh sold $0.54
Annual Non-Fuel Expenses $147,333
Non-Fuel Expense per kWh sold $0.47
Total Expense per kWh sold $1.01
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 127,887 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
84.9%
Community Facility kWh Sold 38,715 Line Loss (%)13.5%
Other kWh Sold (Non-PCE)143,887 Fuel Efficiency (kWh per gallon of diesel)9.53
Total kWh Sold 310,489 PH Consumption as % of generation 1.6%
Powerhouse (PH) Consumption kWh 5,882
Total kWh Sold & PH Consumption 316,371
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 112 of 181
New Stuyahok PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 501
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 107
Community Facility Customers 11
Other Customers (Non-PCE)33
Fiscal Year PCE Payments $279,940
PCE Statistical Data
PCE Eligible kWh - Residential Customers 449,528 Average Annual PCE Payment per Eligible
Customer
$2,372
PCE Eligible kWh - Community Facility
Customers
136,449 Average PCE Payment per Eligible kWh $0.48
Total PCE Eligible kWh 585,977 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.65
Average Monthly PCE Eligible kWh per
Residential Customer
350 Last Reported PCE Level (per kWh)$0.46
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,034 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per person
23 PCE Eligible kWh vs Total kWh Sold 42.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,447,340 Fuel Used (Gallons)105,641
Non-Diesel kWh Generated 0 Fuel Cost $465,917
Purchased kWh 0 Average Price of Fuel $4.41
Total Purchased & Generated 1,447,340 Fuel Cost per kWh sold $0.34
Annual Non-Fuel Expenses $377,569
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.61
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 600,999 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
95.1%
Community Facility kWh Sold 134,529 Line Loss (%)3.0%
Other kWh Sold (Non-PCE)641,422 Fuel Efficiency (kWh per gallon of diesel)13.70
Total kWh Sold 1,376,950 PH Consumption as % of generation 1.8%
Powerhouse (PH) Consumption kWh 26,393
Total kWh Sold & PH Consumption 1,403,343
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 113 of 181
Newtok PCE
Utility: UNGUSRAQ POWER COMPANY
Reporting Period: 07/01/12..06/30/13
Community Population 370
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 66
Community Facility Customers 3
Other Customers (Non-PCE)23
Fiscal Year PCE Payments $174,283
PCE Statistical Data
PCE Eligible kWh - Residential Customers 253,549 Average Annual PCE Payment per Eligible
Customer
$2,526
PCE Eligible kWh - Community Facility
Customers
33,438 Average PCE Payment per Eligible kWh $0.61
Total PCE Eligible kWh 286,987 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.80
Average Monthly PCE Eligible kWh per
Residential Customer
320 Last Reported PCE Level (per kWh)$0.62
Average Monthly PCE Eligible kWh per
Community Facility Customer
929 Effective Residential Rate (per kWh)$0.18
Average Monthly PCE Eligible Community
Facility kWh per person
8 PCE Eligible kWh vs Total kWh Sold 64.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 462,408 Fuel Used (Gallons)42,851
Non-Diesel kWh Generated 0 Fuel Cost $192,650
Purchased kWh 0 Average Price of Fuel $4.50
Total Purchased & Generated 462,408 Fuel Cost per kWh sold $0.43
Annual Non-Fuel Expenses $152,169
Non-Fuel Expense per kWh sold $0.34
Total Expense per kWh sold $0.77
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 276,720 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
97.0%
Community Facility kWh Sold 34,057 Line Loss (%)2.3%
Other kWh Sold (Non-PCE)137,729 Fuel Efficiency (kWh per gallon of diesel)10.79
Total kWh Sold 448,506 PH Consumption as % of generation 0.7%
Powerhouse (PH) Consumption kWh 3,462
Total kWh Sold & PH Consumption 451,968
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 114 of 181
Nightmute PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 289
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 57
Community Facility Customers 8
Other Customers (Non-PCE)19
Fiscal Year PCE Payments $104,109
PCE Statistical Data
PCE Eligible kWh - Residential Customers 239,012 Average Annual PCE Payment per Eligible
Customer
$1,602
PCE Eligible kWh - Community Facility
Customers
63,551 Average PCE Payment per Eligible kWh $0.34
Total PCE Eligible kWh 302,563 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.55
Average Monthly PCE Eligible kWh per
Residential Customer
349 Last Reported PCE Level (per kWh)$0.36
Average Monthly PCE Eligible kWh per
Community Facility Customer
662 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
18 PCE Eligible kWh vs Total kWh Sold 50.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $164,854
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.27
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 280,777 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 63,551 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)256,510 Fuel Efficiency (kWh per gallon of diesel)N/A
Total kWh Sold 600,838 PH Consumption as % of generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 600,838
Comments
Receives power from Toksook Bay via intertie
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 115 of 181
Nikolai PCE
Utility: CITY OF NIKOLAI
Reporting Period: 07/01/12..06/30/13
Community Population 101
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 39
Community Facility Customers 10
Other Customers (Non-PCE)7
Fiscal Year PCE Payments $139,797
PCE Statistical Data
PCE Eligible kWh - Residential Customers 142,115 Average Annual PCE Payment per Eligible
Customer
$2,853
PCE Eligible kWh - Community Facility
Customers
71,273 Average PCE Payment per Eligible kWh $0.66
Total PCE Eligible kWh 213,388 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.90
Average Monthly PCE Eligible kWh per
Residential Customer
304 Last Reported PCE Level (per kWh)$0.66
Average Monthly PCE Eligible kWh per
Community Facility Customer
594 Effective Residential Rate (per kWh)$0.24
Average Monthly PCE Eligible Community
Facility kWh per person
59 PCE Eligible kWh vs Total kWh Sold 59.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 426,555 Fuel Used (Gallons)38,823
Non-Diesel kWh Generated 0 Fuel Cost $246,626
Purchased kWh 0 Average Price of Fuel $6.35
Total Purchased & Generated 426,555 Fuel Cost per kWh sold $0.69
Annual Non-Fuel Expenses $40,474
Non-Fuel Expense per kWh sold $0.11
Total Expense per kWh sold $0.80
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 162,689 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
83.7%
Community Facility kWh Sold 95,131 Line Loss (%)11.5%
Other kWh Sold (Non-PCE)99,314 Fuel Efficiency (kWh per gallon of diesel)10.99
Total kWh Sold 357,134 PH Consumption as % of generation 4.8%
Powerhouse (PH) Consumption kWh 20,383
Total kWh Sold & PH Consumption 377,517
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 116 of 181
Nikolski PCE
Utility: UMNAK POWER COMPANY
Reporting Period: 07/01/12..06/30/13
Community Population 16
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 14
Community Facility Customers 5
Other Customers (Non-PCE)8
Fiscal Year PCE Payments $31,380
PCE Statistical Data
PCE Eligible kWh - Residential Customers 55,237 Average Annual PCE Payment per Eligible
Customer
$1,652
PCE Eligible kWh - Community Facility
Customers
13,429 Average PCE Payment per Eligible kWh $0.46
Total PCE Eligible kWh 68,666 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.60
Average Monthly PCE Eligible kWh per
Residential Customer
329 Last Reported PCE Level (per kWh)$0.46
Average Monthly PCE Eligible kWh per
Community Facility Customer
224 Effective Residential Rate (per kWh)$0.14
Average Monthly PCE Eligible Community
Facility kWh per person
70 PCE Eligible kWh vs Total kWh Sold 37.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 220,037 Fuel Used (Gallons)21,703
Non-Diesel kWh Generated 0 Fuel Cost $125,941
Purchased kWh 0 Average Price of Fuel $5.80
Total Purchased & Generated 220,037 Fuel Cost per kWh sold $0.68
Annual Non-Fuel Expenses $111,702
Non-Fuel Expense per kWh sold $0.60
Total Expense per kWh sold $1.28
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 57,579 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
84.3%
Community Facility kWh Sold 31,240 Line Loss (%)6.1%
Other kWh Sold (Non-PCE)96,607 Fuel Efficiency (kWh per gallon of diesel)10.14
Total kWh Sold 185,426 PH Consumption as % of generation 9.7%
Powerhouse (PH) Consumption kWh 21,279
Total kWh Sold & PH Consumption 206,705
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 117 of 181
Noatak PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 546
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 124
Community Facility Customers 9
Other Customers (Non-PCE)20
Fiscal Year PCE Payments $519,323
PCE Statistical Data
PCE Eligible kWh - Residential Customers 576,401 Average Annual PCE Payment per Eligible
Customer
$3,905
PCE Eligible kWh - Community Facility
Customers
245,424 Average PCE Payment per Eligible kWh $0.63
Total PCE Eligible kWh 821,825 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.87
Average Monthly PCE Eligible kWh per
Residential Customer
387 Last Reported PCE Level (per kWh)$0.67
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,272 Effective Residential Rate (per kWh)$0.21
Average Monthly PCE Eligible Community
Facility kWh per person
37 PCE Eligible kWh vs Total kWh Sold 47.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,896,365 Fuel Used (Gallons)137,419
Non-Diesel kWh Generated 0 Fuel Cost $1,009,318
Purchased kWh 0 Average Price of Fuel $7.34
Total Purchased & Generated 1,896,365 Fuel Cost per kWh sold $0.58
Annual Non-Fuel Expenses $477,960
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.85
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 817,771 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
91.9%
Community Facility kWh Sold 245,424 Line Loss (%)5.9%
Other kWh Sold (Non-PCE)679,872 Fuel Efficiency (kWh per gallon of diesel)13.80
Total kWh Sold 1,743,067 PH Consumption as % of generation 2.2%
Powerhouse (PH) Consumption kWh 42,033
Total kWh Sold & PH Consumption 1,785,100
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 118 of 181
Nome PCE
Utility: NOME JOINT UTILITY SYSTEM
Reporting Period: 07/01/12..06/30/13
Community Population 3695
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 1,694
Community Facility Customers 77
Other Customers (Non-PCE)334
Fiscal Year PCE Payments $1,334,541
PCE Statistical Data
PCE Eligible kWh - Residential Customers 5,600,339 Average Annual PCE Payment per Eligible
Customer
$754
PCE Eligible kWh - Community Facility
Customers
2,238,053 Average PCE Payment per Eligible kWh $0.17
Total PCE Eligible kWh 7,838,392 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.38
Average Monthly PCE Eligible kWh per
Residential Customer
275 Last Reported PCE Level (per kWh)$0.17
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,422 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per person
50 PCE Eligible kWh vs Total kWh Sold 24.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 35,064,764 Fuel Used (Gallons)2,120,963
Non-Diesel kWh Generated 0 Fuel Cost $6,774,844
Purchased kWh 1,183,185 Average Price of Fuel $3.19
Total Purchased & Generated 36,247,949 Fuel Cost per kWh sold $0.21
Annual Non-Fuel Expenses $6,270,590
Non-Fuel Expense per kWh sold $0.19
Total Expense per kWh sold $0.40
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 9,638,175 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
90.2%
Community Facility kWh Sold 3,559,701 Line Loss (%)6.2%
Other kWh Sold (Non-PCE)19,487,632 Fuel Efficiency (kWh per gallon of diesel)16.53
Total kWh Sold 32,685,508 PH Consumption as % of generation 3.7%
Powerhouse (PH) Consumption kWh 1,331,894
Total kWh Sold & PH Consumption 34,017,402
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 119 of 181
Noorvik PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 643
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 148
Community Facility Customers 10
Other Customers (Non-PCE)19
Fiscal Year PCE Payments $434,627
PCE Statistical Data
PCE Eligible kWh - Residential Customers 645,064 Average Annual PCE Payment per Eligible
Customer
$2,751
PCE Eligible kWh - Community Facility
Customers
385,706 Average PCE Payment per Eligible kWh $0.42
Total PCE Eligible kWh 1,030,770 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.65
Average Monthly PCE Eligible kWh per
Residential Customer
363 Last Reported PCE Level (per kWh)$0.45
Average Monthly PCE Eligible kWh per
Community Facility Customer
3,214 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per person
50 PCE Eligible kWh vs Total kWh Sold 54.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,966,403 Fuel Used (Gallons)154,088
Non-Diesel kWh Generated 0 Fuel Cost $657,237
Purchased kWh 0 Average Price of Fuel $4.27
Total Purchased & Generated 1,966,403 Fuel Cost per kWh sold $0.35
Annual Non-Fuel Expenses $517,576
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.62
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 908,300 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
96.0%
Community Facility kWh Sold 385,706 Line Loss (%)2.3%
Other kWh Sold (Non-PCE)593,534 Fuel Efficiency (kWh per gallon of diesel)12.76
Total kWh Sold 1,887,540 PH Consumption as % of generation 1.7%
Powerhouse (PH) Consumption kWh 32,828
Total kWh Sold & PH Consumption 1,920,368
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 120 of 181
Northway; Northway Village PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/12..06/30/13
Community Population 185
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 84
Community Facility Customers 5
Other Customers (Non-PCE)35
Fiscal Year PCE Payments $183,914
PCE Statistical Data
PCE Eligible kWh - Residential Customers 313,418 Average Annual PCE Payment per Eligible
Customer
$2,066
PCE Eligible kWh - Community Facility
Customers
80,927 Average PCE Payment per Eligible kWh $0.47
Total PCE Eligible kWh 394,345 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.69
Average Monthly PCE Eligible kWh per
Residential Customer
311 Last Reported PCE Level (per kWh)$0.47
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,349 Effective Residential Rate (per kWh)$0.21
Average Monthly PCE Eligible Community
Facility kWh per person
36 PCE Eligible kWh vs Total kWh Sold 34.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,256,000 Fuel Used (Gallons)98,861
Non-Diesel kWh Generated 0 Fuel Cost $386,727
Purchased kWh 0 Average Price of Fuel $3.91
Total Purchased & Generated 1,256,000 Fuel Cost per kWh sold $0.33
Annual Non-Fuel Expenses $108,737
Non-Fuel Expense per kWh sold $0.09
Total Expense per kWh sold $0.43
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 377,615 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
92.3%
Community Facility kWh Sold 80,927 Line Loss (%)7.0%
Other kWh Sold (Non-PCE)700,406 Fuel Efficiency (kWh per gallon of diesel)12.70
Total kWh Sold 1,158,948 PH Consumption as % of generation 0.8%
Powerhouse (PH) Consumption kWh 9,696
Total kWh Sold & PH Consumption 1,168,644
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 121 of 181
Nuiqsut PCE
Utility: NORTH SLOPE BOROUGH
Reporting Period: 07/01/12..06/30/13
Community Population 434
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 104
Community Facility Customers 4
Other Customers (Non-PCE)70
Fiscal Year PCE Payments $10,450
PCE Statistical Data
PCE Eligible kWh - Residential Customers 419,009 Average Annual PCE Payment per Eligible
Customer
$97
PCE Eligible kWh - Community Facility
Customers
86,904 Average PCE Payment per Eligible kWh $0.02
Total PCE Eligible kWh 505,913 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.08
Average Monthly PCE Eligible kWh per
Residential Customer
336 Last Reported PCE Level (per kWh)$0.00
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,811 Effective Residential Rate (per kWh)$0.08
Average Monthly PCE Eligible Community
Facility kWh per person
17 PCE Eligible kWh vs Total kWh Sold 9.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,003,258 Fuel Used (Gallons)82,826
Non-Diesel kWh Generated 5,021,389 Fuel Cost $294,048
Purchased kWh 0 Average Price of Fuel $3.55
Total Purchased & Generated 6,024,647 Fuel Cost per kWh sold $0.06
Annual Non-Fuel Expenses $754,328
Non-Fuel Expense per kWh sold $0.15
Total Expense per kWh sold $0.20
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 909,145 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
86.1%
Community Facility kWh Sold 87,813 Line Loss (%)7.8%
Other kWh Sold (Non-PCE)4,191,246 Fuel Efficiency (kWh per gallon of diesel)12.11
Total kWh Sold 5,188,204 PH Consumption as % of generation 6.1%
Powerhouse (PH) Consumption kWh 366,574
Total kWh Sold & PH Consumption 5,554,778
Comments
Res. rate is $0.08, so res. kWh does not qualify for PCE; Aug-Oct gen. < sales
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 122 of 181
Nulato PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 275
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 106
Community Facility Customers 16
Other Customers (Non-PCE)18
Fiscal Year PCE Payments $226,006
PCE Statistical Data
PCE Eligible kWh - Residential Customers 380,993 Average Annual PCE Payment per Eligible
Customer
$1,853
PCE Eligible kWh - Community Facility
Customers
218,525 Average PCE Payment per Eligible kWh $0.38
Total PCE Eligible kWh 599,518 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.60
Average Monthly PCE Eligible kWh per
Residential Customer
300 Last Reported PCE Level (per kWh)$0.40
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,138 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
66 PCE Eligible kWh vs Total kWh Sold 60.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,054,467 Fuel Used (Gallons)82,759
Non-Diesel kWh Generated 0 Fuel Cost $310,181
Purchased kWh 0 Average Price of Fuel $3.75
Total Purchased & Generated 1,054,467 Fuel Cost per kWh sold $0.31
Annual Non-Fuel Expenses $271,253
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.59
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 462,048 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
93.8%
Community Facility kWh Sold 231,095 Line Loss (%)4.7%
Other kWh Sold (Non-PCE)296,087 Fuel Efficiency (kWh per gallon of diesel)12.74
Total kWh Sold 989,230 PH Consumption as % of generation 1.5%
Powerhouse (PH) Consumption kWh 15,424
Total kWh Sold & PH Consumption 1,004,654
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 123 of 181
Nunam Iqua PCE
Utility: NUNAM IQUA ELECTRIC COMPANY
Reporting Period: 07/01/12..06/30/13
Community Population 190
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 38
Community Facility Customers 5
Other Customers (Non-PCE)9
Fiscal Year PCE Payments $80,638
PCE Statistical Data
PCE Eligible kWh - Residential Customers 163,013 Average Annual PCE Payment per Eligible
Customer
$1,875
PCE Eligible kWh - Community Facility
Customers
145,015 Average PCE Payment per Eligible kWh $0.26
Total PCE Eligible kWh 308,028 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.53
Average Monthly PCE Eligible kWh per
Residential Customer
357 Last Reported PCE Level (per kWh)$0.33
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,417 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per person
64 PCE Eligible kWh vs Total kWh Sold 36.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 909,433 Fuel Used (Gallons)71,973
Non-Diesel kWh Generated 0 Fuel Cost $274,090
Purchased kWh 0 Average Price of Fuel $3.81
Total Purchased & Generated 909,433 Fuel Cost per kWh sold $0.33
Annual Non-Fuel Expenses $108,121
Non-Fuel Expense per kWh sold $0.13
Total Expense per kWh sold $0.46
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 187,358 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
91.7%
Community Facility kWh Sold 179,262 Line Loss (%)4.5%
Other kWh Sold (Non-PCE)467,529 Fuel Efficiency (kWh per gallon of diesel)12.64
Total kWh Sold 834,149 PH Consumption as % of generation 3.7%
Powerhouse (PH) Consumption kWh 34,098
Total kWh Sold & PH Consumption 868,247
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 124 of 181
Nunapitchuk PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 518
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 134
Community Facility Customers 10
Other Customers (Non-PCE)24
Fiscal Year PCE Payments $247,424
PCE Statistical Data
PCE Eligible kWh - Residential Customers 549,819 Average Annual PCE Payment per Eligible
Customer
$1,718
PCE Eligible kWh - Community Facility
Customers
124,905 Average PCE Payment per Eligible kWh $0.37
Total PCE Eligible kWh 674,724 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.58
Average Monthly PCE Eligible kWh per
Residential Customer
342 Last Reported PCE Level (per kWh)$0.39
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,041 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
20 PCE Eligible kWh vs Total kWh Sold 56.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $329,525
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.27
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 639,293 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 124,905 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)437,544 Fuel Efficiency (kWh per gallon of diesel)N/A
Total kWh Sold 1,201,742 PH Consumption as % of generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 1,201,742
Comments
Receives power from Kasigluk via intertie
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 125 of 181
Old Harbor PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 208
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 95
Community Facility Customers 12
Other Customers (Non-PCE)19
Fiscal Year PCE Payments $201,704
PCE Statistical Data
PCE Eligible kWh - Residential Customers 335,685 Average Annual PCE Payment per Eligible
Customer
$1,885
PCE Eligible kWh - Community Facility
Customers
170,174 Average PCE Payment per Eligible kWh $0.40
Total PCE Eligible kWh 505,859 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.63
Average Monthly PCE Eligible kWh per
Residential Customer
294 Last Reported PCE Level (per kWh)$0.43
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,182 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per person
68 PCE Eligible kWh vs Total kWh Sold 65.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 845,627 Fuel Used (Gallons)58,192
Non-Diesel kWh Generated 0 Fuel Cost $240,172
Purchased kWh 0 Average Price of Fuel $4.13
Total Purchased & Generated 845,627 Fuel Cost per kWh sold $0.31
Annual Non-Fuel Expenses $212,561
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.58
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 386,479 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
91.7%
Community Facility kWh Sold 199,407 Line Loss (%)4.9%
Other kWh Sold (Non-PCE)189,299 Fuel Efficiency (kWh per gallon of diesel)14.53
Total kWh Sold 775,185 PH Consumption as % of generation 3.4%
Powerhouse (PH) Consumption kWh 29,104
Total kWh Sold & PH Consumption 804,289
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 126 of 181
Ouzinkie PCE
Utility: CITY OF OUZINKIE
Reporting Period: 07/01/12..06/30/13
Community Population 178
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 77
Community Facility Customers 10
Other Customers (Non-PCE)22
Fiscal Year PCE Payments $96,430
PCE Statistical Data
PCE Eligible kWh - Residential Customers 283,534 Average Annual PCE Payment per Eligible
Customer
$1,108
PCE Eligible kWh - Community Facility
Customers
109,527 Average PCE Payment per Eligible kWh $0.25
Total PCE Eligible kWh 393,061 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.37
Average Monthly PCE Eligible kWh per
Residential Customer
307 Last Reported PCE Level (per kWh)$0.22
Average Monthly PCE Eligible kWh per
Community Facility Customer
913 Effective Residential Rate (per kWh)$0.14
Average Monthly PCE Eligible Community
Facility kWh per person
51 PCE Eligible kWh vs Total kWh Sold 57.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 515,092 Fuel Used (Gallons)40,800
Non-Diesel kWh Generated 238,736 Fuel Cost $194,316
Purchased kWh 0 Average Price of Fuel $4.76
Total Purchased & Generated 753,828 Fuel Cost per kWh sold $0.28
Annual Non-Fuel Expenses $167,308
Non-Fuel Expense per kWh sold $0.24
Total Expense per kWh sold $0.52
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 308,609 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
91.6%
Community Facility kWh Sold 141,409 Line Loss (%)3.7%
Other kWh Sold (Non-PCE)240,135 Fuel Efficiency (kWh per gallon of diesel)12.62
Total kWh Sold 690,153 PH Consumption as % of generation 4.8%
Powerhouse (PH) Consumption kWh 36,020
Total kWh Sold & PH Consumption 726,173
Comments
Jan&Feb res. rate caused eff rates < floor; financial adj made to corr res. rate
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 127 of 181
Pedro Bay PCE
Utility: PEDRO BAY VILLAGE COUNCIL
Reporting Period: 07/01/12..06/30/13
Community Population 47
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 24
Community Facility Customers 4
Other Customers (Non-PCE)12
Fiscal Year PCE Payments $35,830
PCE Statistical Data
PCE Eligible kWh - Residential Customers 46,645 Average Annual PCE Payment per Eligible
Customer
$1,280
PCE Eligible kWh - Community Facility
Customers
18,608 Average PCE Payment per Eligible kWh $0.55
Total PCE Eligible kWh 65,253 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.91
Average Monthly PCE Eligible kWh per
Residential Customer
162 Last Reported PCE Level (per kWh)$0.60
Average Monthly PCE Eligible kWh per
Community Facility Customer
388 Effective Residential Rate (per kWh)$0.31
Average Monthly PCE Eligible Community
Facility kWh per person
33 PCE Eligible kWh vs Total kWh Sold 41.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 184,554 Fuel Used (Gallons)19,829
Non-Diesel kWh Generated 0 Fuel Cost $119,481
Purchased kWh 0 Average Price of Fuel $6.03
Total Purchased & Generated 184,554 Fuel Cost per kWh sold $0.77
Annual Non-Fuel Expenses $34,393
Non-Fuel Expense per kWh sold $0.22
Total Expense per kWh sold $0.99
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 57,413 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
84.5%
Community Facility kWh Sold 19,069 Line Loss (%)9.8%
Other kWh Sold (Non-PCE)79,419 Fuel Efficiency (kWh per gallon of diesel)9.31
Total kWh Sold 155,901 PH Consumption as % of generation 5.7%
Powerhouse (PH) Consumption kWh 10,476
Total kWh Sold & PH Consumption 166,377
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 128 of 181
Pelican PCE
Utility: PELICAN UTILITY DISTRICT
Reporting Period: 07/01/12..06/30/13
Community Population 83
Last Reported Month March
No. of Monthly Payments Made 9
Residential Customers 63
Community Facility Customers 28
Other Customers (Non-PCE)9
Fiscal Year PCE Payments $97,954
PCE Statistical Data
PCE Eligible kWh - Residential Customers 164,455 Average Annual PCE Payment per Eligible
Customer
$1,076
PCE Eligible kWh - Community Facility
Customers
47,664 Average PCE Payment per Eligible kWh $0.46
Total PCE Eligible kWh 212,119 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.61
Average Monthly PCE Eligible kWh per
Residential Customer
290 Last Reported PCE Level (per kWh)$0.47
Average Monthly PCE Eligible kWh per
Community Facility Customer
189 Effective Residential Rate (per kWh)$0.14
Average Monthly PCE Eligible Community
Facility kWh per person
64 PCE Eligible kWh vs Total kWh Sold 35.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 626,751 Fuel Used (Gallons)39,739
Non-Diesel kWh Generated 56,000 Fuel Cost $178,694
Purchased kWh 0 Average Price of Fuel $4.50
Total Purchased & Generated 682,751 Fuel Cost per kWh sold $0.30
Annual Non-Fuel Expenses $244,592
Non-Fuel Expense per kWh sold $0.41
Total Expense per kWh sold $0.71
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 239,085 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
87.1%
Community Facility kWh Sold 198,099 Line Loss (%)5.7%
Other kWh Sold (Non-PCE)157,722 Fuel Efficiency (kWh per gallon of diesel)15.77
Total kWh Sold 594,906 PH Consumption as % of generation 7.2%
Powerhouse (PH) Consumption kWh 49,030
Total kWh Sold & PH Consumption 643,936
Comments
Only 9 months reported, Apr-Jun not submitted
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 129 of 181
Perryville PCE
Utility: NATIVE VILLAGE OF PERRYVILLE
Reporting Period: 07/01/12..06/30/13
Community Population 130
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 52
Community Facility Customers 6
Other Customers (Non-PCE)14
Fiscal Year PCE Payments $39,687
PCE Statistical Data
PCE Eligible kWh - Residential Customers 121,417 Average Annual PCE Payment per Eligible
Customer
$684
PCE Eligible kWh - Community Facility
Customers
0 Average PCE Payment per Eligible kWh $0.33
Total PCE Eligible kWh 121,417 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.95
Average Monthly PCE Eligible kWh per
Residential Customer
195 Last Reported PCE Level (per kWh)$0.33
Average Monthly PCE Eligible kWh per
Community Facility Customer
0 Effective Residential Rate (per kWh)$0.62
Average Monthly PCE Eligible Community
Facility kWh per person
0 PCE Eligible kWh vs Total kWh Sold 31.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 473,200 Fuel Used (Gallons)26,929
Non-Diesel kWh Generated 37,804 Fuel Cost $122,380
Purchased kWh 0 Average Price of Fuel $4.54
Total Purchased & Generated 511,004 Fuel Cost per kWh sold $0.31
Annual Non-Fuel Expenses $38,148
Non-Fuel Expense per kWh sold $0.10
Total Expense per kWh sold $0.41
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 139,041 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
76.2%
Community Facility kWh Sold 83,274 Line Loss (%)22.3%
Other kWh Sold (Non-PCE)166,837 Fuel Efficiency (kWh per gallon of diesel)17.57
Total kWh Sold 389,152 PH Consumption as % of generation 1.6%
Powerhouse (PH) Consumption kWh 8,041
Total kWh Sold & PH Consumption 397,193
Comments
Nov 2012 non-fuel $ are estimates
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 130 of 181
Pilot Point PCE
Utility: PILOT POINT ELECTRIC UTILITY
Reporting Period: 07/01/12..06/30/13
Community Population 88
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 47
Community Facility Customers 10
Other Customers (Non-PCE)20
Fiscal Year PCE Payments $65,291
PCE Statistical Data
PCE Eligible kWh - Residential Customers 117,637 Average Annual PCE Payment per Eligible
Customer
$1,145
PCE Eligible kWh - Community Facility
Customers
65,250 Average PCE Payment per Eligible kWh $0.36
Total PCE Eligible kWh 182,887 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.50
Average Monthly PCE Eligible kWh per
Residential Customer
209 Last Reported PCE Level (per kWh)$0.36
Average Monthly PCE Eligible kWh per
Community Facility Customer
544 Effective Residential Rate (per kWh)$0.14
Average Monthly PCE Eligible Community
Facility kWh per person
62 PCE Eligible kWh vs Total kWh Sold 46.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 461,224 Fuel Used (Gallons)39,787
Non-Diesel kWh Generated 0 Fuel Cost $169,050
Purchased kWh 0 Average Price of Fuel $4.25
Total Purchased & Generated 461,224 Fuel Cost per kWh sold $0.43
Annual Non-Fuel Expenses $38,422
Non-Fuel Expense per kWh sold $0.10
Total Expense per kWh sold $0.52
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 155,498 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
86.0%
Community Facility kWh Sold 66,228 Line Loss (%)9.6%
Other kWh Sold (Non-PCE)174,939 Fuel Efficiency (kWh per gallon of diesel)11.59
Total kWh Sold 396,665 PH Consumption as % of generation 4.4%
Powerhouse (PH) Consumption kWh 20,258
Total kWh Sold & PH Consumption 416,923
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 131 of 181
Pilot Station PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 583
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 136
Community Facility Customers 11
Other Customers (Non-PCE)17
Fiscal Year PCE Payments $282,371
PCE Statistical Data
PCE Eligible kWh - Residential Customers 551,860 Average Annual PCE Payment per Eligible
Customer
$1,921
PCE Eligible kWh - Community Facility
Customers
219,403 Average PCE Payment per Eligible kWh $0.37
Total PCE Eligible kWh 771,263 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.58
Average Monthly PCE Eligible kWh per
Residential Customer
338 Last Reported PCE Level (per kWh)$0.39
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,662 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
31 PCE Eligible kWh vs Total kWh Sold 44.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,834,048 Fuel Used (Gallons)136,551
Non-Diesel kWh Generated 0 Fuel Cost $489,795
Purchased kWh 0 Average Price of Fuel $3.59
Total Purchased & Generated 1,834,048 Fuel Cost per kWh sold $0.28
Annual Non-Fuel Expenses $478,066
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.56
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 754,168 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
95.1%
Community Facility kWh Sold 219,403 Line Loss (%)3.5%
Other kWh Sold (Non-PCE)769,883 Fuel Efficiency (kWh per gallon of diesel)13.43
Total kWh Sold 1,743,454 PH Consumption as % of generation 1.4%
Powerhouse (PH) Consumption kWh 26,066
Total kWh Sold & PH Consumption 1,769,520
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 132 of 181
Pitkas Point PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 93
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 29
Community Facility Customers 6
Other Customers (Non-PCE)4
Fiscal Year PCE Payments $69,897
PCE Statistical Data
PCE Eligible kWh - Residential Customers 119,432 Average Annual PCE Payment per Eligible
Customer
$1,997
PCE Eligible kWh - Community Facility
Customers
73,504 Average PCE Payment per Eligible kWh $0.36
Total PCE Eligible kWh 192,936 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.59
Average Monthly PCE Eligible kWh per
Residential Customer
343 Last Reported PCE Level (per kWh)$0.39
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,021 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
66 PCE Eligible kWh vs Total kWh Sold 68.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $76,818
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.27
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 130,482 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 114,272 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)35,391 Fuel Efficiency (kWh per gallon of diesel)N/A
Total kWh Sold 280,145 PH Consumption as % of generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 280,145
Comments
Receives power from St. Mary's/Andreafsky via intertie
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 133 of 181
Point Hope PCE
Utility: NORTH SLOPE BOROUGH
Reporting Period: 07/01/12..06/30/13
Community Population 656
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 180
Community Facility Customers 2
Other Customers (Non-PCE)83
Fiscal Year PCE Payments $15,975
PCE Statistical Data
PCE Eligible kWh - Residential Customers 429,271 Average Annual PCE Payment per Eligible
Customer
$88
PCE Eligible kWh - Community Facility
Customers
95,148 Average PCE Payment per Eligible kWh $0.03
Total PCE Eligible kWh 524,419 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.15
Average Monthly PCE Eligible kWh per
Residential Customer
199 Last Reported PCE Level (per kWh)$0.01
Average Monthly PCE Eligible kWh per
Community Facility Customer
3,965 Effective Residential Rate (per kWh)$0.14
Average Monthly PCE Eligible Community
Facility kWh per person
12 PCE Eligible kWh vs Total kWh Sold 9.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 6,620,140 Fuel Used (Gallons)433,556
Non-Diesel kWh Generated 0 Fuel Cost $1,712,474
Purchased kWh 0 Average Price of Fuel $3.95
Total Purchased & Generated 6,620,140 Fuel Cost per kWh sold $0.32
Annual Non-Fuel Expenses $929,374
Non-Fuel Expense per kWh sold $0.17
Total Expense per kWh sold $0.49
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,660,720 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
81.1%
Community Facility kWh Sold 95,148 Line Loss (%)13.0%
Other kWh Sold (Non-PCE)3,613,631 Fuel Efficiency (kWh per gallon of diesel)15.27
Total kWh Sold 5,369,499 PH Consumption as % of generation 5.9%
Powerhouse (PH) Consumption kWh 391,444
Total kWh Sold & PH Consumption 5,760,943
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 134 of 181
Point Lay PCE
Utility: NORTH SLOPE BOROUGH
Reporting Period: 07/01/12..06/30/13
Community Population 196
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 58
Community Facility Customers 1
Other Customers (Non-PCE)48
Fiscal Year PCE Payments $3,596
PCE Statistical Data
PCE Eligible kWh - Residential Customers 91,658 Average Annual PCE Payment per Eligible
Customer
$61
PCE Eligible kWh - Community Facility
Customers
24,308 Average PCE Payment per Eligible kWh $0.03
Total PCE Eligible kWh 115,966 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.15
Average Monthly PCE Eligible kWh per
Residential Customer
132 Last Reported PCE Level (per kWh)$0.01
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,026 Effective Residential Rate (per kWh)$0.14
Average Monthly PCE Eligible Community
Facility kWh per person
10 PCE Eligible kWh vs Total kWh Sold 3.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 3,934,800 Fuel Used (Gallons)282,473
Non-Diesel kWh Generated 0 Fuel Cost $1,118,628
Purchased kWh 0 Average Price of Fuel $3.96
Total Purchased & Generated 3,934,800 Fuel Cost per kWh sold $0.33
Annual Non-Fuel Expenses $715,300
Non-Fuel Expense per kWh sold $0.21
Total Expense per kWh sold $0.54
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 444,562 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
86.4%
Community Facility kWh Sold 24,308 Line Loss (%)2.0%
Other kWh Sold (Non-PCE)2,930,176 Fuel Efficiency (kWh per gallon of diesel)13.93
Total kWh Sold 3,399,046 PH Consumption as % of generation 11.6%
Powerhouse (PH) Consumption kWh 455,616
Total kWh Sold & PH Consumption 3,854,662
Comments
Dec,Jan,Feb,Jun reported generation < sales
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 135 of 181
Port Alsworth PCE
Utility: TANALIAN ELECTRIC COOPERATIVE
Reporting Period: 07/01/12..06/30/13
Community Population 156
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 67
Community Facility Customers 0
Other Customers (Non-PCE)56
Fiscal Year PCE Payments $116,093
PCE Statistical Data
PCE Eligible kWh - Residential Customers 229,310 Average Annual PCE Payment per Eligible
Customer
$1,733
PCE Eligible kWh - Community Facility
Customers
0 Average PCE Payment per Eligible kWh $0.51
Total PCE Eligible kWh 229,310 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.69
Average Monthly PCE Eligible kWh per
Residential Customer
285 Last Reported PCE Level (per kWh)$0.49
Average Monthly PCE Eligible kWh per
Community Facility Customer
0 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per person
0 PCE Eligible kWh vs Total kWh Sold 32.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 767,295 Fuel Used (Gallons)64,572
Non-Diesel kWh Generated 0 Fuel Cost $346,109
Purchased kWh 0 Average Price of Fuel $5.36
Total Purchased & Generated 767,295 Fuel Cost per kWh sold $0.49
Annual Non-Fuel Expenses $210,020
Non-Fuel Expense per kWh sold $0.30
Total Expense per kWh sold $0.79
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 273,547 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
91.5%
Community Facility kWh Sold 0 Line Loss (%)6.3%
Other kWh Sold (Non-PCE)428,515 Fuel Efficiency (kWh per gallon of diesel)11.88
Total kWh Sold 702,062 PH Consumption as % of generation 2.2%
Powerhouse (PH) Consumption kWh 16,752
Total kWh Sold & PH Consumption 718,814
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 136 of 181
Port Heiden PCE
Utility: PORT HEIDEN UTILITIES
Reporting Period: 07/01/12..06/30/13
Community Population 101
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 52
Community Facility Customers 5
Other Customers (Non-PCE)28
Fiscal Year PCE Payments $70,277
PCE Statistical Data
PCE Eligible kWh - Residential Customers 170,173 Average Annual PCE Payment per Eligible
Customer
$1,233
PCE Eligible kWh - Community Facility
Customers
47,128 Average PCE Payment per Eligible kWh $0.32
Total PCE Eligible kWh 217,301 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.75
Average Monthly PCE Eligible kWh per
Residential Customer
273 Last Reported PCE Level (per kWh)$0.33
Average Monthly PCE Eligible kWh per
Community Facility Customer
785 Effective Residential Rate (per kWh)$0.42
Average Monthly PCE Eligible Community
Facility kWh per person
39 PCE Eligible kWh vs Total kWh Sold 35.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 612,400 Fuel Used (Gallons)61,218
Non-Diesel kWh Generated 0 Fuel Cost $285,816
Purchased kWh 0 Average Price of Fuel $4.67
Total Purchased & Generated 612,400 Fuel Cost per kWh sold $0.46
Annual Non-Fuel Expenses $81,541
Non-Fuel Expense per kWh sold $0.13
Total Expense per kWh sold $0.59
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 203,368 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 57,009 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)357,442 Fuel Efficiency (kWh per gallon of diesel)10.00
Total kWh Sold 617,819 PH Consumption as % of generation 5.7%
Powerhouse (PH) Consumption kWh 34,606
Total kWh Sold & PH Consumption 652,425
Comments
Jul-Jun diesel kWH generation unreliable due to broken meter
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 137 of 181
Quinhagak PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 675
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 174
Community Facility Customers 25
Other Customers (Non-PCE)19
Fiscal Year PCE Payments $318,906
PCE Statistical Data
PCE Eligible kWh - Residential Customers 736,192 Average Annual PCE Payment per Eligible
Customer
$1,603
PCE Eligible kWh - Community Facility
Customers
279,409 Average PCE Payment per Eligible kWh $0.31
Total PCE Eligible kWh 1,015,601 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.52
Average Monthly PCE Eligible kWh per
Residential Customer
353 Last Reported PCE Level (per kWh)$0.33
Average Monthly PCE Eligible kWh per
Community Facility Customer
931 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
34 PCE Eligible kWh vs Total kWh Sold 53.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,415,362 Fuel Used (Gallons)119,788
Non-Diesel kWh Generated 628,961 Fuel Cost $471,620
Purchased kWh 0 Average Price of Fuel $3.94
Total Purchased & Generated 2,044,323 Fuel Cost per kWh sold $0.25
Annual Non-Fuel Expenses $518,628
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.52
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 882,047 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
92.5%
Community Facility kWh Sold 279,409 Line Loss (%)4.9%
Other kWh Sold (Non-PCE)729,921 Fuel Efficiency (kWh per gallon of diesel)11.82
Total kWh Sold 1,891,377 PH Consumption as % of generation 2.6%
Powerhouse (PH) Consumption kWh 52,881
Total kWh Sold & PH Consumption 1,944,258
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 138 of 181
Red Devil PCE
Utility: MIDDLE KUSKOKWIM ELECTRIC
Reporting Period: 07/01/12..06/30/13
Community Population 19
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 15
Community Facility Customers 1
Other Customers (Non-PCE)5
Fiscal Year PCE Payments $31,020
PCE Statistical Data
PCE Eligible kWh - Residential Customers 44,197 Average Annual PCE Payment per Eligible
Customer
$1,939
PCE Eligible kWh - Community Facility
Customers
0 Average PCE Payment per Eligible kWh $0.70
Total PCE Eligible kWh 44,197 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.80
Average Monthly PCE Eligible kWh per
Residential Customer
246 Last Reported PCE Level (per kWh)$0.61
Average Monthly PCE Eligible kWh per
Community Facility Customer
0 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
0 PCE Eligible kWh vs Total kWh Sold 54.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 110,731 Fuel Used (Gallons)11,982
Non-Diesel kWh Generated 0 Fuel Cost $53,318
Purchased kWh 0 Average Price of Fuel $4.45
Total Purchased & Generated 110,731 Fuel Cost per kWh sold $0.65
Annual Non-Fuel Expenses $81,844
Non-Fuel Expense per kWh sold $1.00
Total Expense per kWh sold $1.66
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 61,778 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
73.6%
Community Facility kWh Sold 229 Line Loss (%)24.8%
Other kWh Sold (Non-PCE)19,469 Fuel Efficiency (kWh per gallon of diesel)9.24
Total kWh Sold 81,476 PH Consumption as % of generation 1.6%
Powerhouse (PH) Consumption kWh 1,797
Total kWh Sold & PH Consumption 83,273
Comments
Sep-Nov powerhouse consumption not reported
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 139 of 181
Ruby PCE
Utility: CITY OF RUBY
Reporting Period: 07/01/12..06/30/13
Community Population 173
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 130
Community Facility Customers 18
Other Customers (Non-PCE)18
Fiscal Year PCE Payments $114,438
PCE Statistical Data
PCE Eligible kWh - Residential Customers 237,916 Average Annual PCE Payment per Eligible
Customer
$773
PCE Eligible kWh - Community Facility
Customers
69,907 Average PCE Payment per Eligible kWh $0.37
Total PCE Eligible kWh 307,823 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.84
Average Monthly PCE Eligible kWh per
Residential Customer
153 Last Reported PCE Level (per kWh)$0.42
Average Monthly PCE Eligible kWh per
Community Facility Customer
324 Effective Residential Rate (per kWh)$0.42
Average Monthly PCE Eligible Community
Facility kWh per person
34 PCE Eligible kWh vs Total kWh Sold 46.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 666,842 Fuel Used (Gallons)47,590
Non-Diesel kWh Generated 0 Fuel Cost $204,322
Purchased kWh 0 Average Price of Fuel $4.29
Total Purchased & Generated 666,842 Fuel Cost per kWh sold $0.31
Annual Non-Fuel Expenses $155,813
Non-Fuel Expense per kWh sold $0.23
Total Expense per kWh sold $0.54
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 276,031 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 69,907 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)322,497 Fuel Efficiency (kWh per gallon of diesel)14.01
Total kWh Sold 668,435 PH Consumption as % of generation 3.9%
Powerhouse (PH) Consumption kWh 25,731
Total kWh Sold & PH Consumption 694,166
Comments
Reported diesel generation erroneous, sales exceeded generation
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 140 of 181
Russian Mission PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 303
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 71
Community Facility Customers 6
Other Customers (Non-PCE)19
Fiscal Year PCE Payments $150,253
PCE Statistical Data
PCE Eligible kWh - Residential Customers 316,075 Average Annual PCE Payment per Eligible
Customer
$1,951
PCE Eligible kWh - Community Facility
Customers
76,679 Average PCE Payment per Eligible kWh $0.38
Total PCE Eligible kWh 392,754 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.60
Average Monthly PCE Eligible kWh per
Residential Customer
371 Last Reported PCE Level (per kWh)$0.41
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,065 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
21 PCE Eligible kWh vs Total kWh Sold 41.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,031,366 Fuel Used (Gallons)75,527
Non-Diesel kWh Generated 0 Fuel Cost $275,405
Purchased kWh 0 Average Price of Fuel $3.65
Total Purchased & Generated 1,031,366 Fuel Cost per kWh sold $0.29
Annual Non-Fuel Expenses $261,973
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.56
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 367,175 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
92.6%
Community Facility kWh Sold 85,079 Line Loss (%)5.7%
Other kWh Sold (Non-PCE)503,131 Fuel Efficiency (kWh per gallon of diesel)13.66
Total kWh Sold 955,385 PH Consumption as % of generation 1.7%
Powerhouse (PH) Consumption kWh 17,562
Total kWh Sold & PH Consumption 972,947
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 141 of 181
Sand Point PCE
Utility: TDX CORPORATION
Reporting Period: 07/01/12..06/30/13
Community Population 1016
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 296
Community Facility Customers 29
Other Customers (Non-PCE)167
Fiscal Year PCE Payments $617,769
PCE Statistical Data
PCE Eligible kWh - Residential Customers 1,107,681 Average Annual PCE Payment per Eligible
Customer
$1,901
PCE Eligible kWh - Community Facility
Customers
385,633 Average PCE Payment per Eligible kWh $0.41
Total PCE Eligible kWh 1,493,314 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.49
Average Monthly PCE Eligible kWh per
Residential Customer
312 Last Reported PCE Level (per kWh)$0.29
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,108 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per person
32 PCE Eligible kWh vs Total kWh Sold 38.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 3,646,151 Fuel Used (Gallons)252,426
Non-Diesel kWh Generated 0 Fuel Cost $1,155,886
Purchased kWh 634,809 Average Price of Fuel $4.58
Total Purchased & Generated 4,280,960 Fuel Cost per kWh sold $0.30
Annual Non-Fuel Expenses $517,701
Non-Fuel Expense per kWh sold $0.13
Total Expense per kWh sold $0.43
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,497,349 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
90.1%
Community Facility kWh Sold 464,098 Line Loss (%)7.2%
Other kWh Sold (Non-PCE)1,896,420 Fuel Efficiency (kWh per gallon of diesel)14.44
Total kWh Sold 3,857,867 PH Consumption as % of generation 2.7%
Powerhouse (PH) Consumption kWh 114,880
Total kWh Sold & PH Consumption 3,972,747
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 142 of 181
Savoonga PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 704
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 164
Community Facility Customers 12
Other Customers (Non-PCE)29
Fiscal Year PCE Payments $313,828
PCE Statistical Data
PCE Eligible kWh - Residential Customers 670,136 Average Annual PCE Payment per Eligible
Customer
$1,783
PCE Eligible kWh - Community Facility
Customers
302,337 Average PCE Payment per Eligible kWh $0.32
Total PCE Eligible kWh 972,473 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.54
Average Monthly PCE Eligible kWh per
Residential Customer
341 Last Reported PCE Level (per kWh)$0.35
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,100 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
36 PCE Eligible kWh vs Total kWh Sold 46.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,870,137 Fuel Used (Gallons)134,248
Non-Diesel kWh Generated 305,498 Fuel Cost $582,896
Purchased kWh 0 Average Price of Fuel $4.34
Total Purchased & Generated 2,175,635 Fuel Cost per kWh sold $0.28
Annual Non-Fuel Expenses $569,759
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.55
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 881,783 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
95.5%
Community Facility kWh Sold 302,337 Line Loss (%)3.1%
Other kWh Sold (Non-PCE)893,726 Fuel Efficiency (kWh per gallon of diesel)13.93
Total kWh Sold 2,077,846 PH Consumption as % of generation 1.4%
Powerhouse (PH) Consumption kWh 30,649
Total kWh Sold & PH Consumption 2,108,495
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 143 of 181
Scammon Bay PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 498
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 122
Community Facility Customers 8
Other Customers (Non-PCE)37
Fiscal Year PCE Payments $269,140
PCE Statistical Data
PCE Eligible kWh - Residential Customers 465,035 Average Annual PCE Payment per Eligible
Customer
$2,070
PCE Eligible kWh - Community Facility
Customers
169,622 Average PCE Payment per Eligible kWh $0.42
Total PCE Eligible kWh 634,657 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.64
Average Monthly PCE Eligible kWh per
Residential Customer
318 Last Reported PCE Level (per kWh)$0.44
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,767 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per person
28 PCE Eligible kWh vs Total kWh Sold 40.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,676,629 Fuel Used (Gallons)125,610
Non-Diesel kWh Generated 0 Fuel Cost $451,077
Purchased kWh 0 Average Price of Fuel $3.59
Total Purchased & Generated 1,676,629 Fuel Cost per kWh sold $0.29
Annual Non-Fuel Expenses $427,875
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.56
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 561,857 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
93.1%
Community Facility kWh Sold 169,622 Line Loss (%)5.1%
Other kWh Sold (Non-PCE)828,934 Fuel Efficiency (kWh per gallon of diesel)13.35
Total kWh Sold 1,560,413 PH Consumption as % of generation 1.9%
Powerhouse (PH) Consumption kWh 31,504
Total kWh Sold & PH Consumption 1,591,917
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 144 of 181
Selawik PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 868
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 196
Community Facility Customers 18
Other Customers (Non-PCE)36
Fiscal Year PCE Payments $586,694
PCE Statistical Data
PCE Eligible kWh - Residential Customers 786,877 Average Annual PCE Payment per Eligible
Customer
$2,742
PCE Eligible kWh - Community Facility
Customers
666,206 Average PCE Payment per Eligible kWh $0.40
Total PCE Eligible kWh 1,453,083 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.62
Average Monthly PCE Eligible kWh per
Residential Customer
335 Last Reported PCE Level (per kWh)$0.42
Average Monthly PCE Eligible kWh per
Community Facility Customer
3,084 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per person
64 PCE Eligible kWh vs Total kWh Sold 51.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,891,097 Fuel Used (Gallons)216,918
Non-Diesel kWh Generated 95,609 Fuel Cost $789,563
Purchased kWh 0 Average Price of Fuel $3.64
Total Purchased & Generated 2,986,706 Fuel Cost per kWh sold $0.28
Annual Non-Fuel Expenses $778,505
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.55
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,127,625 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
95.1%
Community Facility kWh Sold 765,776 Line Loss (%)3.4%
Other kWh Sold (Non-PCE)945,719 Fuel Efficiency (kWh per gallon of diesel)13.33
Total kWh Sold 2,839,120 PH Consumption as % of generation 1.6%
Powerhouse (PH) Consumption kWh 47,233
Total kWh Sold & PH Consumption 2,886,353
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 145 of 181
Shageluk PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 83
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 35
Community Facility Customers 7
Other Customers (Non-PCE)10
Fiscal Year PCE Payments $65,394
PCE Statistical Data
PCE Eligible kWh - Residential Customers 94,809 Average Annual PCE Payment per Eligible
Customer
$1,557
PCE Eligible kWh - Community Facility
Customers
56,097 Average PCE Payment per Eligible kWh $0.43
Total PCE Eligible kWh 150,906 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.66
Average Monthly PCE Eligible kWh per
Residential Customer
226 Last Reported PCE Level (per kWh)$0.46
Average Monthly PCE Eligible kWh per
Community Facility Customer
668 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per person
56 PCE Eligible kWh vs Total kWh Sold 44.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 375,128 Fuel Used (Gallons)31,341
Non-Diesel kWh Generated 0 Fuel Cost $179,855
Purchased kWh 0 Average Price of Fuel $5.74
Total Purchased & Generated 375,128 Fuel Cost per kWh sold $0.53
Annual Non-Fuel Expenses $92,706
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.81
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 107,582 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
90.1%
Community Facility kWh Sold 57,233 Line Loss (%)6.8%
Other kWh Sold (Non-PCE)173,273 Fuel Efficiency (kWh per gallon of diesel)11.97
Total kWh Sold 338,088 PH Consumption as % of generation 3.0%
Powerhouse (PH) Consumption kWh 11,381
Total kWh Sold & PH Consumption 349,469
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 146 of 181
Shaktoolik PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 258
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 72
Community Facility Customers 5
Other Customers (Non-PCE)23
Fiscal Year PCE Payments $133,696
PCE Statistical Data
PCE Eligible kWh - Residential Customers 282,355 Average Annual PCE Payment per Eligible
Customer
$1,736
PCE Eligible kWh - Community Facility
Customers
83,302 Average PCE Payment per Eligible kWh $0.37
Total PCE Eligible kWh 365,657 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.57
Average Monthly PCE Eligible kWh per
Residential Customer
327 Last Reported PCE Level (per kWh)$0.38
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,388 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
27 PCE Eligible kWh vs Total kWh Sold 39.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 804,186 Fuel Used (Gallons)60,545
Non-Diesel kWh Generated 238,745 Fuel Cost $311,296
Purchased kWh 0 Average Price of Fuel $5.14
Total Purchased & Generated 1,042,931 Fuel Cost per kWh sold $0.33
Annual Non-Fuel Expenses $255,631
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.61
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 477,319 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
89.4%
Community Facility kWh Sold 83,302 Line Loss (%)1.9%
Other kWh Sold (Non-PCE)371,636 Fuel Efficiency (kWh per gallon of diesel)13.28
Total kWh Sold 932,257 PH Consumption as % of generation 8.7%
Powerhouse (PH) Consumption kWh 90,485
Total kWh Sold & PH Consumption 1,022,742
Comments
Oct,Jan reported generation < sales
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 147 of 181
Shishmaref PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 573
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 148
Community Facility Customers 10
Other Customers (Non-PCE)32
Fiscal Year PCE Payments $283,339
PCE Statistical Data
PCE Eligible kWh - Residential Customers 590,335 Average Annual PCE Payment per Eligible
Customer
$1,793
PCE Eligible kWh - Community Facility
Customers
138,506 Average PCE Payment per Eligible kWh $0.39
Total PCE Eligible kWh 728,841 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.60
Average Monthly PCE Eligible kWh per
Residential Customer
332 Last Reported PCE Level (per kWh)$0.41
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,154 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
20 PCE Eligible kWh vs Total kWh Sold 45.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,641,227 Fuel Used (Gallons)119,197
Non-Diesel kWh Generated 0 Fuel Cost $591,549
Purchased kWh 0 Average Price of Fuel $4.96
Total Purchased & Generated 1,641,227 Fuel Cost per kWh sold $0.37
Annual Non-Fuel Expenses $435,610
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.65
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 749,940 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
96.8%
Community Facility kWh Sold 138,506 Line Loss (%)0.8%
Other kWh Sold (Non-PCE)700,173 Fuel Efficiency (kWh per gallon of diesel)13.77
Total kWh Sold 1,588,619 PH Consumption as % of generation 2.4%
Powerhouse (PH) Consumption kWh 39,655
Total kWh Sold & PH Consumption 1,628,274
Comments
Nov,Jun reported generation < sales
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 148 of 181
Shungnak PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 261
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 66
Community Facility Customers 7
Other Customers (Non-PCE)17
Fiscal Year PCE Payments $233,070
PCE Statistical Data
PCE Eligible kWh - Residential Customers 284,613 Average Annual PCE Payment per Eligible
Customer
$3,193
PCE Eligible kWh - Community Facility
Customers
151,988 Average PCE Payment per Eligible kWh $0.53
Total PCE Eligible kWh 436,601 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.68
Average Monthly PCE Eligible kWh per
Residential Customer
359 Last Reported PCE Level (per kWh)$0.48
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,809 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per person
49 PCE Eligible kWh vs Total kWh Sold 44.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,732,010 Fuel Used (Gallons)122,825
Non-Diesel kWh Generated 0 Fuel Cost $626,144
Purchased kWh 0 Average Price of Fuel $5.10
Total Purchased & Generated 1,732,010 Fuel Cost per kWh sold $0.64
Annual Non-Fuel Expenses $268,787
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.91
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 413,554 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
56.6%
Community Facility kWh Sold 151,988 Line Loss (%)40.7%
Other kWh Sold (Non-PCE)414,693 Fuel Efficiency (kWh per gallon of diesel)14.10
Total kWh Sold 980,235 PH Consumption as % of generation 2.7%
Powerhouse (PH) Consumption kWh 46,628
Total kWh Sold & PH Consumption 1,026,863
Comments
Provides power to Kobuk
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 149 of 181
Skagway PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/12..06/30/13
Community Population 965
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 619
Community Facility Customers 42
Other Customers (Non-PCE)526
Fiscal Year PCE Payments $161,131
PCE Statistical Data
PCE Eligible kWh - Residential Customers 1,953,154 Average Annual PCE Payment per Eligible
Customer
$244
PCE Eligible kWh - Community Facility
Customers
810,600 Average PCE Payment per Eligible kWh $0.06
Total PCE Eligible kWh 2,763,754 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.26
Average Monthly PCE Eligible kWh per
Residential Customer
263 Last Reported PCE Level (per kWh)$0.08
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,608 Effective Residential Rate (per kWh)$0.18
Average Monthly PCE Eligible Community
Facility kWh per person
70 PCE Eligible kWh vs Total kWh Sold 22.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 234,960 Fuel Used (Gallons)16,972
Non-Diesel kWh Generated 3,268,160 Fuel Cost $67,833
Purchased kWh 9,790,465 Average Price of Fuel $4.00
Total Purchased & Generated 13,293,585 Fuel Cost per kWh sold $0.01
Annual Non-Fuel Expenses $942,904
Non-Fuel Expense per kWh sold $0.08
Total Expense per kWh sold $0.08
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 3,108,794 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
92.2%
Community Facility kWh Sold 1,165,752 Line Loss (%)7.0%
Other kWh Sold (Non-PCE)7,977,750 Fuel Efficiency (kWh per gallon of diesel)13.84
Total kWh Sold 12,252,296 PH Consumption as % of generation 0.8%
Powerhouse (PH) Consumption kWh 110,687
Total kWh Sold & PH Consumption 12,362,983
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 150 of 181
Slana PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/12..06/30/13
Community Population 147
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 79
Community Facility Customers 1
Other Customers (Non-PCE)17
Fiscal Year PCE Payments $110,344
PCE Statistical Data
PCE Eligible kWh - Residential Customers 233,344 Average Annual PCE Payment per Eligible
Customer
$1,379
PCE Eligible kWh - Community Facility
Customers
2,744 Average PCE Payment per Eligible kWh $0.47
Total PCE Eligible kWh 236,088 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.69
Average Monthly PCE Eligible kWh per
Residential Customer
246 Last Reported PCE Level (per kWh)$0.42
Average Monthly PCE Eligible kWh per
Community Facility Customer
229 Effective Residential Rate (per kWh)$0.27
Average Monthly PCE Eligible Community
Facility kWh per person
2 PCE Eligible kWh vs Total kWh Sold 46.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,393,344 Fuel Used (Gallons)116,522
Non-Diesel kWh Generated 0 Fuel Cost $438,527
Purchased kWh 0 Average Price of Fuel $3.76
Total Purchased & Generated 1,393,344 Fuel Cost per kWh sold $0.86
Annual Non-Fuel Expenses $150,183
Non-Fuel Expense per kWh sold $0.29
Total Expense per kWh sold $1.16
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 300,917 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
36.6%
Community Facility kWh Sold 2,744 Line Loss (%)62.0%
Other kWh Sold (Non-PCE)205,875 Fuel Efficiency (kWh per gallon of diesel)11.96
Total kWh Sold 509,536 PH Consumption as % of generation 1.4%
Powerhouse (PH) Consumption kWh 20,112
Total kWh Sold & PH Consumption 529,648
Comments
Shares generation as part of Slana-Chistochina grid.
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 151 of 181
Sleetmute PCE
Utility: MIDDLE KUSKOKWIM ELECTRIC
Reporting Period: 07/01/12..06/30/13
Community Population 93
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 34
Community Facility Customers 2
Other Customers (Non-PCE)14
Fiscal Year PCE Payments $85,509
PCE Statistical Data
PCE Eligible kWh - Residential Customers 83,841 Average Annual PCE Payment per Eligible
Customer
$2,375
PCE Eligible kWh - Community Facility
Customers
38,015 Average PCE Payment per Eligible kWh $0.70
Total PCE Eligible kWh 121,856 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.80
Average Monthly PCE Eligible kWh per
Residential Customer
205 Last Reported PCE Level (per kWh)$0.61
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,584 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
34 PCE Eligible kWh vs Total kWh Sold 49.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 264,498 Fuel Used (Gallons)24,293
Non-Diesel kWh Generated 0 Fuel Cost $108,314
Purchased kWh 0 Average Price of Fuel $4.46
Total Purchased & Generated 264,498 Fuel Cost per kWh sold $0.44
Annual Non-Fuel Expenses $81,844
Non-Fuel Expense per kWh sold $0.33
Total Expense per kWh sold $0.77
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 108,638 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
93.0%
Community Facility kWh Sold 46,092 Line Loss (%)1.4%
Other kWh Sold (Non-PCE)91,257 Fuel Efficiency (kWh per gallon of diesel)10.89
Total kWh Sold 245,987 PH Consumption as % of generation 5.6%
Powerhouse (PH) Consumption kWh 14,912
Total kWh Sold & PH Consumption 260,899
Comments
Jul,Oct,May reported generation < consumed
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 152 of 181
St. George PCE
Utility: CITY OF ST. GEORGE
Reporting Period: 07/01/12..06/30/13
Community Population 97
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 42
Community Facility Customers 7
Other Customers (Non-PCE)30
Fiscal Year PCE Payments $128,084
PCE Statistical Data
PCE Eligible kWh - Residential Customers 129,223 Average Annual PCE Payment per Eligible
Customer
$2,614
PCE Eligible kWh - Community Facility
Customers
6,790 Average PCE Payment per Eligible kWh $0.94
Total PCE Eligible kWh 136,013 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.00
Average Monthly PCE Eligible kWh per
Residential Customer
256 Last Reported PCE Level (per kWh)$0.66
Average Monthly PCE Eligible kWh per
Community Facility Customer
81 Effective Residential Rate (per kWh)$0.34
Average Monthly PCE Eligible Community
Facility kWh per person
6 PCE Eligible kWh vs Total kWh Sold 22.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 756,892 Fuel Used (Gallons)53,725
Non-Diesel kWh Generated 0 Fuel Cost $372,370
Purchased kWh 0 Average Price of Fuel $6.93
Total Purchased & Generated 756,892 Fuel Cost per kWh sold $0.61
Annual Non-Fuel Expenses $121,511
Non-Fuel Expense per kWh sold $0.20
Total Expense per kWh sold $0.81
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 168,524 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
80.3%
Community Facility kWh Sold 130,738 Line Loss (%)13.5%
Other kWh Sold (Non-PCE)308,707 Fuel Efficiency (kWh per gallon of diesel)14.09
Total kWh Sold 607,969 PH Consumption as % of generation 6.2%
Powerhouse (PH) Consumption kWh 46,764
Total kWh Sold & PH Consumption 654,733
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 153 of 181
St. Mary's; Andreafsky PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 554
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 182
Community Facility Customers 17
Other Customers (Non-PCE)50
Fiscal Year PCE Payments $402,113
PCE Statistical Data
PCE Eligible kWh - Residential Customers 642,412 Average Annual PCE Payment per Eligible
Customer
$2,021
PCE Eligible kWh - Community Facility
Customers
471,228 Average PCE Payment per Eligible kWh $0.36
Total PCE Eligible kWh 1,113,640 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.59
Average Monthly PCE Eligible kWh per
Residential Customer
294 Last Reported PCE Level (per kWh)$0.39
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,310 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
71 PCE Eligible kWh vs Total kWh Sold 39.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 3,272,505 Fuel Used (Gallons)251,812
Non-Diesel kWh Generated 0 Fuel Cost $848,878
Purchased kWh 0 Average Price of Fuel $3.37
Total Purchased & Generated 3,272,505 Fuel Cost per kWh sold $0.30
Annual Non-Fuel Expenses $780,481
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.57
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 892,744 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
87.0%
Community Facility kWh Sold 471,804 Line Loss (%)11.6%
Other kWh Sold (Non-PCE)1,481,777 Fuel Efficiency (kWh per gallon of diesel)13.00
Total kWh Sold 2,846,325 PH Consumption as % of generation 1.4%
Powerhouse (PH) Consumption kWh 46,461
Total kWh Sold & PH Consumption 2,892,786
Comments
Provides power to Pitkas Point via intertie
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 154 of 181
St. Michael PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 411
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 99
Community Facility Customers 10
Other Customers (Non-PCE)21
Fiscal Year PCE Payments $269,907
PCE Statistical Data
PCE Eligible kWh - Residential Customers 415,378 Average Annual PCE Payment per Eligible
Customer
$2,476
PCE Eligible kWh - Community Facility
Customers
291,347 Average PCE Payment per Eligible kWh $0.38
Total PCE Eligible kWh 706,725 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.59
Average Monthly PCE Eligible kWh per
Residential Customer
350 Last Reported PCE Level (per kWh)$0.40
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,428 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
59 PCE Eligible kWh vs Total kWh Sold 42.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,777,253 Fuel Used (Gallons)134,645
Non-Diesel kWh Generated 0 Fuel Cost $529,587
Purchased kWh 0 Average Price of Fuel $3.93
Total Purchased & Generated 1,777,253 Fuel Cost per kWh sold $0.31
Annual Non-Fuel Expenses $461,475
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.59
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 657,117 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
94.7%
Community Facility kWh Sold 312,474 Line Loss (%)2.8%
Other kWh Sold (Non-PCE)713,355 Fuel Efficiency (kWh per gallon of diesel)13.20
Total kWh Sold 1,682,946 PH Consumption as % of generation 2.5%
Powerhouse (PH) Consumption kWh 44,350
Total kWh Sold & PH Consumption 1,727,296
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 155 of 181
St. Paul PCE
Utility: ST. PAUL MUNICIPAL ELECTRIC
Reporting Period: 07/01/12..06/30/13
Community Population 481
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 149
Community Facility Customers 31
Other Customers (Non-PCE)50
Fiscal Year PCE Payments $392,482
PCE Statistical Data
PCE Eligible kWh - Residential Customers 687,765 Average Annual PCE Payment per Eligible
Customer
$2,180
PCE Eligible kWh - Community Facility
Customers
404,040 Average PCE Payment per Eligible kWh $0.36
Total PCE Eligible kWh 1,091,805 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.53
Average Monthly PCE Eligible kWh per
Residential Customer
385 Last Reported PCE Level (per kWh)$0.36
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,086 Effective Residential Rate (per kWh)$0.17
Average Monthly PCE Eligible Community
Facility kWh per person
70 PCE Eligible kWh vs Total kWh Sold 28.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 4,557,125 Fuel Used (Gallons)309,664
Non-Diesel kWh Generated 0 Fuel Cost $1,497,287
Purchased kWh 0 Average Price of Fuel $4.84
Total Purchased & Generated 4,557,125 Fuel Cost per kWh sold $0.40
Annual Non-Fuel Expenses $666,681
Non-Fuel Expense per kWh sold $0.18
Total Expense per kWh sold $0.57
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 808,212 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
82.9%
Community Facility kWh Sold 700,004 Line Loss (%)13.2%
Other kWh Sold (Non-PCE)2,269,954 Fuel Efficiency (kWh per gallon of diesel)14.72
Total kWh Sold 3,778,170 PH Consumption as % of generation 3.9%
Powerhouse (PH) Consumption kWh 176,500
Total kWh Sold & PH Consumption 3,954,670
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 156 of 181
Stebbins PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 585
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 143
Community Facility Customers 13
Other Customers (Non-PCE)21
Fiscal Year PCE Payments $244,456
PCE Statistical Data
PCE Eligible kWh - Residential Customers 491,745 Average Annual PCE Payment per Eligible
Customer
$1,567
PCE Eligible kWh - Community Facility
Customers
143,600 Average PCE Payment per Eligible kWh $0.38
Total PCE Eligible kWh 635,345 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.59
Average Monthly PCE Eligible kWh per
Residential Customer
287 Last Reported PCE Level (per kWh)$0.40
Average Monthly PCE Eligible kWh per
Community Facility Customer
921 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
20 PCE Eligible kWh vs Total kWh Sold 46.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,439,927 Fuel Used (Gallons)102,362
Non-Diesel kWh Generated 0 Fuel Cost $390,251
Purchased kWh 0 Average Price of Fuel $3.81
Total Purchased & Generated 1,439,927 Fuel Cost per kWh sold $0.29
Annual Non-Fuel Expenses $371,628
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.56
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 609,283 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
94.1%
Community Facility kWh Sold 148,160 Line Loss (%)3.7%
Other kWh Sold (Non-PCE)597,843 Fuel Efficiency (kWh per gallon of diesel)14.07
Total kWh Sold 1,355,286 PH Consumption as % of generation 2.2%
Powerhouse (PH) Consumption kWh 31,078
Total kWh Sold & PH Consumption 1,386,364
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 157 of 181
Stony River PCE
Utility: MIDDLE KUSKOKWIM ELECTRIC
Reporting Period: 07/01/12..06/30/13
Community Population 46
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 18
Community Facility Customers 0
Other Customers (Non-PCE)9
Fiscal Year PCE Payments $26,501
PCE Statistical Data
PCE Eligible kWh - Residential Customers 37,601 Average Annual PCE Payment per Eligible
Customer
$1,472
PCE Eligible kWh - Community Facility
Customers
0 Average PCE Payment per Eligible kWh $0.70
Total PCE Eligible kWh 37,601 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.80
Average Monthly PCE Eligible kWh per
Residential Customer
174 Last Reported PCE Level (per kWh)$0.61
Average Monthly PCE Eligible kWh per
Community Facility Customer
0 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
0 PCE Eligible kWh vs Total kWh Sold 35.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 54,266 Fuel Used (Gallons)15,857
Non-Diesel kWh Generated 0 Fuel Cost $70,518
Purchased kWh 0 Average Price of Fuel $4.45
Total Purchased & Generated 54,266 Fuel Cost per kWh sold $0.66
Annual Non-Fuel Expenses $81,662
Non-Fuel Expense per kWh sold $0.76
Total Expense per kWh sold $1.42
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 41,137 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 0 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)66,003 Fuel Efficiency (kWh per gallon of diesel)3.42
Total kWh Sold 107,140 PH Consumption as % of generation 0.0%
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 107,140
Comments
Dec-Jun kWh generated & pwrhouse use not reported due to meter failure
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 158 of 181
Takotna PCE
Utility: TAKOTNA COMMUNITY ASSOC INC
Reporting Period: 07/01/12..06/30/13
Community Population 49
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 24
Community Facility Customers 5
Other Customers (Non-PCE)13
Fiscal Year PCE Payments $57,165
PCE Statistical Data
PCE Eligible kWh - Residential Customers 59,416 Average Annual PCE Payment per Eligible
Customer
$1,971
PCE Eligible kWh - Community Facility
Customers
36,890 Average PCE Payment per Eligible kWh $0.59
Total PCE Eligible kWh 96,306 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.02
Average Monthly PCE Eligible kWh per
Residential Customer
206 Last Reported PCE Level (per kWh)$0.60
Average Monthly PCE Eligible kWh per
Community Facility Customer
615 Effective Residential Rate (per kWh)$0.43
Average Monthly PCE Eligible Community
Facility kWh per person
63 PCE Eligible kWh vs Total kWh Sold 52.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 221,274 Fuel Used (Gallons)21,337
Non-Diesel kWh Generated 0 Fuel Cost $110,790
Purchased kWh 0 Average Price of Fuel $5.19
Total Purchased & Generated 221,274 Fuel Cost per kWh sold $0.60
Annual Non-Fuel Expenses $46,671
Non-Fuel Expense per kWh sold $0.25
Total Expense per kWh sold $0.85
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 63,921 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
83.7%
Community Facility kWh Sold 38,839 Line Loss (%)7.2%
Other kWh Sold (Non-PCE)82,463 Fuel Efficiency (kWh per gallon of diesel)10.37
Total kWh Sold 185,223 PH Consumption as % of generation 9.1%
Powerhouse (PH) Consumption kWh 20,089
Total kWh Sold & PH Consumption 205,312
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 159 of 181
Tanana PCE
Utility: TANANA POWER COMPANY INC.
Reporting Period: 07/01/12..06/30/13
Community Population 231
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 108
Community Facility Customers 11
Other Customers (Non-PCE)38
Fiscal Year PCE Payments $195,732
PCE Statistical Data
PCE Eligible kWh - Residential Customers 294,208 Average Annual PCE Payment per Eligible
Customer
$1,645
PCE Eligible kWh - Community Facility
Customers
146,903 Average PCE Payment per Eligible kWh $0.44
Total PCE Eligible kWh 441,111 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.76
Average Monthly PCE Eligible kWh per
Residential Customer
227 Last Reported PCE Level (per kWh)$0.46
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,113 Effective Residential Rate (per kWh)$0.30
Average Monthly PCE Eligible Community
Facility kWh per person
53 PCE Eligible kWh vs Total kWh Sold 41.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,176,044 Fuel Used (Gallons)90,214
Non-Diesel kWh Generated 0 Fuel Cost $345,569
Purchased kWh 0 Average Price of Fuel $3.83
Total Purchased & Generated 1,176,044 Fuel Cost per kWh sold $0.33
Annual Non-Fuel Expenses $364,663
Non-Fuel Expense per kWh sold $0.34
Total Expense per kWh sold $0.67
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 327,928 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
90.0%
Community Facility kWh Sold 159,710 Line Loss (%)6.7%
Other kWh Sold (Non-PCE)570,855 Fuel Efficiency (kWh per gallon of diesel)13.04
Total kWh Sold 1,058,493 PH Consumption as % of generation 3.3%
Powerhouse (PH) Consumption kWh 39,202
Total kWh Sold & PH Consumption 1,097,695
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 160 of 181
Tatitlek PCE
Utility: TATITLEK VILLAGE IRA COUNCIL
Reporting Period: 07/01/12..06/30/13
Community Population 86
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 53
Community Facility Customers 5
Other Customers (Non-PCE)20
Fiscal Year PCE Payments $88,297
PCE Statistical Data
PCE Eligible kWh - Residential Customers 115,235 Average Annual PCE Payment per Eligible
Customer
$1,522
PCE Eligible kWh - Community Facility
Customers
59,505 Average PCE Payment per Eligible kWh $0.51
Total PCE Eligible kWh 174,740 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.87
Average Monthly PCE Eligible kWh per
Residential Customer
181 Last Reported PCE Level (per kWh)$0.53
Average Monthly PCE Eligible kWh per
Community Facility Customer
992 Effective Residential Rate (per kWh)$0.34
Average Monthly PCE Eligible Community
Facility kWh per person
58 PCE Eligible kWh vs Total kWh Sold 42.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 507,700 Fuel Used (Gallons)42,068
Non-Diesel kWh Generated 0 Fuel Cost $222,832
Purchased kWh 0 Average Price of Fuel $5.30
Total Purchased & Generated 507,700 Fuel Cost per kWh sold $0.54
Annual Non-Fuel Expenses $67,963
Non-Fuel Expense per kWh sold $0.16
Total Expense per kWh sold $0.70
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 130,826 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
81.9%
Community Facility kWh Sold 77,347 Line Loss (%)8.0%
Other kWh Sold (Non-PCE)207,794 Fuel Efficiency (kWh per gallon of diesel)12.07
Total kWh Sold 415,967 PH Consumption as % of generation 10.1%
Powerhouse (PH) Consumption kWh 51,332
Total kWh Sold & PH Consumption 467,299
Comments
Mar 13 kWh generated estimated based on sold kwh
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 161 of 181
Teller PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 245
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 76
Community Facility Customers 7
Other Customers (Non-PCE)24
Fiscal Year PCE Payments $132,163
PCE Statistical Data
PCE Eligible kWh - Residential Customers 246,761 Average Annual PCE Payment per Eligible
Customer
$1,592
PCE Eligible kWh - Community Facility
Customers
62,440 Average PCE Payment per Eligible kWh $0.43
Total PCE Eligible kWh 309,201 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.64
Average Monthly PCE Eligible kWh per
Residential Customer
271 Last Reported PCE Level (per kWh)$0.45
Average Monthly PCE Eligible kWh per
Community Facility Customer
743 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per person
21 PCE Eligible kWh vs Total kWh Sold 39.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 865,055 Fuel Used (Gallons)67,031
Non-Diesel kWh Generated 0 Fuel Cost $259,410
Purchased kWh 0 Average Price of Fuel $3.87
Total Purchased & Generated 865,055 Fuel Cost per kWh sold $0.33
Annual Non-Fuel Expenses $216,361
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.60
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 291,669 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
91.2%
Community Facility kWh Sold 67,212 Line Loss (%)5.1%
Other kWh Sold (Non-PCE)430,163 Fuel Efficiency (kWh per gallon of diesel)12.91
Total kWh Sold 789,044 PH Consumption as % of generation 3.6%
Powerhouse (PH) Consumption kWh 31,477
Total kWh Sold & PH Consumption 820,521
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 162 of 181
Tenakee Springs PCE
Utility: CITY OF TENAKEE SPRINGS
Reporting Period: 07/01/12..06/30/13
Community Population 145
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 128
Community Facility Customers 13
Other Customers (Non-PCE)23
Fiscal Year PCE Payments $110,242
PCE Statistical Data
PCE Eligible kWh - Residential Customers 206,547 Average Annual PCE Payment per Eligible
Customer
$782
PCE Eligible kWh - Community Facility
Customers
32,192 Average PCE Payment per Eligible kWh $0.46
Total PCE Eligible kWh 238,739 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.74
Average Monthly PCE Eligible kWh per
Residential Customer
134 Last Reported PCE Level (per kWh)$0.47
Average Monthly PCE Eligible kWh per
Community Facility Customer
206 Effective Residential Rate (per kWh)$0.27
Average Monthly PCE Eligible Community
Facility kWh per person
19 PCE Eligible kWh vs Total kWh Sold 66.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 427,102 Fuel Used (Gallons)31,987
Non-Diesel kWh Generated 0 Fuel Cost $152,747
Purchased kWh 0 Average Price of Fuel $4.78
Total Purchased & Generated 427,102 Fuel Cost per kWh sold $0.42
Annual Non-Fuel Expenses $83,069
Non-Fuel Expense per kWh sold $0.23
Total Expense per kWh sold $0.65
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 246,755 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
84.4%
Community Facility kWh Sold 32,192 Line Loss (%)14.1%
Other kWh Sold (Non-PCE)81,390 Fuel Efficiency (kWh per gallon of diesel)13.35
Total kWh Sold 360,337 PH Consumption as % of generation 1.5%
Powerhouse (PH) Consumption kWh 6,429
Total kWh Sold & PH Consumption 366,766
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 163 of 181
Tetlin PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/12..06/30/13
Community Population 107
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 46
Community Facility Customers 4
Other Customers (Non-PCE)9
Fiscal Year PCE Payments $55,736
PCE Statistical Data
PCE Eligible kWh - Residential Customers 134,698 Average Annual PCE Payment per Eligible
Customer
$1,115
PCE Eligible kWh - Community Facility
Customers
67,740 Average PCE Payment per Eligible kWh $0.28
Total PCE Eligible kWh 202,438 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.50
Average Monthly PCE Eligible kWh per
Residential Customer
244 Last Reported PCE Level (per kWh)$0.29
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,411 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per person
53 PCE Eligible kWh vs Total kWh Sold 58.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $51,463
Non-Fuel Expense per kWh sold $0.15
Total Expense per kWh sold $0.15
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 167,356 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 67,740 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)112,627 Fuel Efficiency (kWh per gallon of diesel)N/A
Total kWh Sold 347,723 PH Consumption as % of generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 347,723
Comments
See Tok for power generation
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 164 of 181
Thorne Bay; Kasaan PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/12..06/30/13
Community Population 562
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 311
Community Facility Customers 33
Other Customers (Non-PCE)125
Fiscal Year PCE Payments $92,142
PCE Statistical Data
PCE Eligible kWh - Residential Customers 966,489 Average Annual PCE Payment per Eligible
Customer
$268
PCE Eligible kWh - Community Facility
Customers
331,614 Average PCE Payment per Eligible kWh $0.07
Total PCE Eligible kWh 1,298,103 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.26
Average Monthly PCE Eligible kWh per
Residential Customer
259 Last Reported PCE Level (per kWh)$0.08
Average Monthly PCE Eligible kWh per
Community Facility Customer
837 Effective Residential Rate (per kWh)$0.18
Average Monthly PCE Eligible Community
Facility kWh per person
49 PCE Eligible kWh vs Total kWh Sold 38.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $73,437
Non-Fuel Expense per kWh sold $0.02
Total Expense per kWh sold $0.02
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,401,009 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 352,019 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)1,615,366 Fuel Efficiency (kWh per gallon of diesel)N/A
Total kWh Sold 3,368,394 PH Consumption as % of generation N/A
Powerhouse (PH) Consumption kWh 66,854
Total kWh Sold & PH Consumption 3,435,248
Comments
See Craig for power generation
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 165 of 181
Togiak PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 842
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 256
Community Facility Customers 20
Other Customers (Non-PCE)39
Fiscal Year PCE Payments $504,033
PCE Statistical Data
PCE Eligible kWh - Residential Customers 943,342 Average Annual PCE Payment per Eligible
Customer
$1,826
PCE Eligible kWh - Community Facility
Customers
294,097 Average PCE Payment per Eligible kWh $0.41
Total PCE Eligible kWh 1,237,439 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.62
Average Monthly PCE Eligible kWh per
Residential Customer
307 Last Reported PCE Level (per kWh)$0.43
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,225 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per person
29 PCE Eligible kWh vs Total kWh Sold 42.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 3,057,620 Fuel Used (Gallons)232,233
Non-Diesel kWh Generated 0 Fuel Cost $987,279
Purchased kWh 0 Average Price of Fuel $4.25
Total Purchased & Generated 3,057,620 Fuel Cost per kWh sold $0.34
Annual Non-Fuel Expenses $799,604
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.61
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,300,823 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
95.4%
Community Facility kWh Sold 294,097 Line Loss (%)3.3%
Other kWh Sold (Non-PCE)1,321,146 Fuel Efficiency (kWh per gallon of diesel)13.17
Total kWh Sold 2,916,066 PH Consumption as % of generation 1.3%
Powerhouse (PH) Consumption kWh 39,730
Total kWh Sold & PH Consumption 2,955,796
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 166 of 181
Tok; Tanacross PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/12..06/30/13
Community Population 1404
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 769
Community Facility Customers 7
Other Customers (Non-PCE)212
Fiscal Year PCE Payments $811,064
PCE Statistical Data
PCE Eligible kWh - Residential Customers 2,846,345 Average Annual PCE Payment per Eligible
Customer
$1,045
PCE Eligible kWh - Community Facility
Customers
79,852 Average PCE Payment per Eligible kWh $0.28
Total PCE Eligible kWh 2,926,197 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.50
Average Monthly PCE Eligible kWh per
Residential Customer
308 Last Reported PCE Level (per kWh)$0.29
Average Monthly PCE Eligible kWh per
Community Facility Customer
951 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per person
5 PCE Eligible kWh vs Total kWh Sold 35.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 10,012,400 Fuel Used (Gallons)719,492
Non-Diesel kWh Generated 0 Fuel Cost $2,746,574
Purchased kWh 0 Average Price of Fuel $3.82
Total Purchased & Generated 10,012,400 Fuel Cost per kWh sold $0.34
Annual Non-Fuel Expenses $1,399,210
Non-Fuel Expense per kWh sold $0.17
Total Expense per kWh sold $0.51
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 3,999,207 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
81.6%
Community Facility kWh Sold 79,852 Line Loss (%)17.0%
Other kWh Sold (Non-PCE)4,090,411 Fuel Efficiency (kWh per gallon of diesel)13.92
Total kWh Sold 8,169,470 PH Consumption as % of generation 1.4%
Powerhouse (PH) Consumption kWh 142,040
Total kWh Sold & PH Consumption 8,311,510
Comments
Power generation include Dot Lake/Dot Lake Village & Tetlin
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 167 of 181
Toksook Bay PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 598
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 136
Community Facility Customers 12
Other Customers (Non-PCE)29
Fiscal Year PCE Payments $290,752
PCE Statistical Data
PCE Eligible kWh - Residential Customers 582,394 Average Annual PCE Payment per Eligible
Customer
$1,965
PCE Eligible kWh - Community Facility
Customers
270,017 Average PCE Payment per Eligible kWh $0.34
Total PCE Eligible kWh 852,411 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.55
Average Monthly PCE Eligible kWh per
Residential Customer
357 Last Reported PCE Level (per kWh)$0.36
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,875 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
38 PCE Eligible kWh vs Total kWh Sold 53.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,609,319 Fuel Used (Gallons)189,212
Non-Diesel kWh Generated 726,450 Fuel Cost $718,541
Purchased kWh 0 Average Price of Fuel $3.80
Total Purchased & Generated 3,335,769 Fuel Cost per kWh sold $0.45
Annual Non-Fuel Expenses $439,815
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.72
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 713,904 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
48.1%
Community Facility kWh Sold 263,681 Line Loss (%)47.2%
Other kWh Sold (Non-PCE)626,370 Fuel Efficiency (kWh per gallon of diesel)13.79
Total kWh Sold 1,603,955 PH Consumption as % of generation 4.7%
Powerhouse (PH) Consumption kWh 156,858
Total kWh Sold & PH Consumption 1,760,813
Comments
Provides power to Nightmute and Tununak via intertie
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 168 of 181
Tuluksak PCE
Utility: TULUKSAK TRADITIONAL
Reporting Period: 07/01/12..06/30/13
Community Population 373
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 96
Community Facility Customers 5
Other Customers (Non-PCE)18
Fiscal Year PCE Payments $108,915
PCE Statistical Data
PCE Eligible kWh - Residential Customers 222,973 Average Annual PCE Payment per Eligible
Customer
$1,078
PCE Eligible kWh - Community Facility
Customers
23,068 Average PCE Payment per Eligible kWh $0.44
Total PCE Eligible kWh 246,041 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.60
Average Monthly PCE Eligible kWh per
Residential Customer
194 Last Reported PCE Level (per kWh)$0.44
Average Monthly PCE Eligible kWh per
Community Facility Customer
384 Effective Residential Rate (per kWh)$0.16
Average Monthly PCE Eligible Community
Facility kWh per person
5 PCE Eligible kWh vs Total kWh Sold 44.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 723,787 Fuel Used (Gallons)56,061
Non-Diesel kWh Generated 0 Fuel Cost $242,254
Purchased kWh 0 Average Price of Fuel $4.32
Total Purchased & Generated 723,787 Fuel Cost per kWh sold $0.43
Annual Non-Fuel Expenses $61,146
Non-Fuel Expense per kWh sold $0.11
Total Expense per kWh sold $0.54
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 307,903 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
77.3%
Community Facility kWh Sold 55,862 Line Loss (%)14.8%
Other kWh Sold (Non-PCE)195,795 Fuel Efficiency (kWh per gallon of diesel)12.91
Total kWh Sold 559,560 PH Consumption as % of generation 7.9%
Powerhouse (PH) Consumption kWh 57,257
Total kWh Sold & PH Consumption 616,817
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 169 of 181
Tuntutuliak PCE
Utility: TUNTUTULIAK COMMUNITY
Reporting Period: 07/01/12..06/30/13
Community Population 428
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 95
Community Facility Customers 7
Other Customers (Non-PCE)31
Fiscal Year PCE Payments $197,964
PCE Statistical Data
PCE Eligible kWh - Residential Customers 390,105 Average Annual PCE Payment per Eligible
Customer
$1,941
PCE Eligible kWh - Community Facility
Customers
14,166 Average PCE Payment per Eligible kWh $0.49
Total PCE Eligible kWh 404,271 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.65
Average Monthly PCE Eligible kWh per
Residential Customer
342 Last Reported PCE Level (per kWh)$0.46
Average Monthly PCE Eligible kWh per
Community Facility Customer
169 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
3 PCE Eligible kWh vs Total kWh Sold 41.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 859,558 Fuel Used (Gallons)86,492
Non-Diesel kWh Generated 196,349 Fuel Cost $405,792
Purchased kWh 0 Average Price of Fuel $4.69
Total Purchased & Generated 1,055,907 Fuel Cost per kWh sold $0.41
Annual Non-Fuel Expenses $345,504
Non-Fuel Expense per kWh sold $0.35
Total Expense per kWh sold $0.76
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 486,407 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
93.4%
Community Facility kWh Sold 52,157 Line Loss (%)3.4%
Other kWh Sold (Non-PCE)447,793 Fuel Efficiency (kWh per gallon of diesel)9.94
Total kWh Sold 986,357 PH Consumption as % of generation 3.1%
Powerhouse (PH) Consumption kWh 33,254
Total kWh Sold & PH Consumption 1,019,611
Comments
Oct,Dec,Jan,Mar,Jun reported generation < sales
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 170 of 181
Tununak PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 342
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 92
Community Facility Customers 8
Other Customers (Non-PCE)20
Fiscal Year PCE Payments $150,630
PCE Statistical Data
PCE Eligible kWh - Residential Customers 353,791 Average Annual PCE Payment per Eligible
Customer
$1,506
PCE Eligible kWh - Community Facility
Customers
83,787 Average PCE Payment per Eligible kWh $0.34
Total PCE Eligible kWh 437,578 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.55
Average Monthly PCE Eligible kWh per
Residential Customer
320 Last Reported PCE Level (per kWh)$0.36
Average Monthly PCE Eligible kWh per
Community Facility Customer
873 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
20 PCE Eligible kWh vs Total kWh Sold 51.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $232,242
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.27
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 435,279 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 83,787 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)327,894 Fuel Efficiency (kWh per gallon of diesel)N/A
Total kWh Sold 846,960 PH Consumption as % of generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 846,960
Comments
Receives power from Toksook Bay via intertie
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 171 of 181
Twin Hills PCE
Utility: TWIN HILLS VILLAGE COUNCIL
Reporting Period: 07/01/12..06/30/13
Community Population 79
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 29
Community Facility Customers 6
Other Customers (Non-PCE)9
Fiscal Year PCE Payments $58,095
PCE Statistical Data
PCE Eligible kWh - Residential Customers 97,560 Average Annual PCE Payment per Eligible
Customer
$1,660
PCE Eligible kWh - Community Facility
Customers
43,875 Average PCE Payment per Eligible kWh $0.41
Total PCE Eligible kWh 141,435 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.00
Average Monthly PCE Eligible kWh per
Residential Customer
280 Last Reported PCE Level (per kWh)$0.46
Average Monthly PCE Eligible kWh per
Community Facility Customer
609 Effective Residential Rate (per kWh)$0.54
Average Monthly PCE Eligible Community
Facility kWh per person
46 PCE Eligible kWh vs Total kWh Sold 51.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 321,257 Fuel Used (Gallons)37,237
Non-Diesel kWh Generated 0 Fuel Cost $170,387
Purchased kWh 0 Average Price of Fuel $4.58
Total Purchased & Generated 321,257 Fuel Cost per kWh sold $0.62
Annual Non-Fuel Expenses $19,536
Non-Fuel Expense per kWh sold $0.07
Total Expense per kWh sold $0.69
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 105,004 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
85.9%
Community Facility kWh Sold 44,602 Line Loss (%)7.4%
Other kWh Sold (Non-PCE)126,348 Fuel Efficiency (kWh per gallon of diesel)8.63
Total kWh Sold 275,954 PH Consumption as % of generation 6.7%
Powerhouse (PH) Consumption kWh 21,681
Total kWh Sold & PH Consumption 297,635
Comments
Jul-Aug 12 kWh generation estimated; Feb,May reptd generation < sales
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 172 of 181
Unalakleet PCE
Utility: UNALAKLEET VALLEY ELECTRIC
Reporting Period: 07/01/12..06/30/13
Community Population 692
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 284
Community Facility Customers 15
Other Customers (Non-PCE)62
Fiscal Year PCE Payments $287,426
PCE Statistical Data
PCE Eligible kWh - Residential Customers 985,872 Average Annual PCE Payment per Eligible
Customer
$961
PCE Eligible kWh - Community Facility
Customers
386,950 Average PCE Payment per Eligible kWh $0.21
Total PCE Eligible kWh 1,372,822 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.42
Average Monthly PCE Eligible kWh per
Residential Customer
289 Last Reported PCE Level (per kWh)$0.21
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,150 Effective Residential Rate (per kWh)$0.21
Average Monthly PCE Eligible Community
Facility kWh per person
47 PCE Eligible kWh vs Total kWh Sold 33.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 3,306,720 Fuel Used (Gallons)226,047
Non-Diesel kWh Generated 1,173,526 Fuel Cost $828,671
Purchased kWh 0 Average Price of Fuel $3.67
Total Purchased & Generated 4,480,246 Fuel Cost per kWh sold $0.20
Annual Non-Fuel Expenses $1,219,742
Non-Fuel Expense per kWh sold $0.29
Total Expense per kWh sold $0.50
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,495,135 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
92.3%
Community Facility kWh Sold 398,694 Line Loss (%)6.0%
Other kWh Sold (Non-PCE)2,243,594 Fuel Efficiency (kWh per gallon of diesel)14.63
Total kWh Sold 4,137,423 PH Consumption as % of generation 1.6%
Powerhouse (PH) Consumption kWh 72,075
Total kWh Sold & PH Consumption 4,209,498
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 173 of 181
Unalaska PCE
Utility: CITY OF UNALASKA
Reporting Period: 07/01/12..06/30/13
Community Population 4364
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 696
Community Facility Customers 56
Other Customers (Non-PCE)199
Fiscal Year PCE Payments $1,065,789
PCE Statistical Data
PCE Eligible kWh - Residential Customers 1,884,725 Average Annual PCE Payment per Eligible
Customer
$1,417
PCE Eligible kWh - Community Facility
Customers
2,976,755 Average PCE Payment per Eligible kWh $0.22
Total PCE Eligible kWh 4,861,480 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.45
Average Monthly PCE Eligible kWh per
Residential Customer
226 Last Reported PCE Level (per kWh)$0.23
Average Monthly PCE Eligible kWh per
Community Facility Customer
4,430 Effective Residential Rate (per kWh)$0.21
Average Monthly PCE Eligible Community
Facility kWh per person
57 PCE Eligible kWh vs Total kWh Sold 10.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 44,773,777 Fuel Used (Gallons)2,848,151
Non-Diesel kWh Generated 0 Fuel Cost $9,916,512
Purchased kWh 0 Average Price of Fuel $3.48
Total Purchased & Generated 44,773,777 Fuel Cost per kWh sold $0.22
Annual Non-Fuel Expenses $3,004,904
Non-Fuel Expense per kWh sold $0.07
Total Expense per kWh sold $0.28
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 4,015,437 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 3,245,028 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)38,149,731 Fuel Efficiency (kWh per gallon of diesel)15.72
Total kWh Sold 45,410,196 PH Consumption as % of generation 2.3%
Powerhouse (PH) Consumption kWh 1,033,099
Total kWh Sold & PH Consumption 46,443,295
Comments
PLC/Demand Meter/SCADA malfunctions caused reporting errors/excessive line loss
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 174 of 181
Upper Kalskag PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 219
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 60
Community Facility Customers 11
Other Customers (Non-PCE)18
Fiscal Year PCE Payments $102,965
PCE Statistical Data
PCE Eligible kWh - Residential Customers 258,568 Average Annual PCE Payment per Eligible
Customer
$1,450
PCE Eligible kWh - Community Facility
Customers
11,831 Average PCE Payment per Eligible kWh $0.38
Total PCE Eligible kWh 270,399 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.61
Average Monthly PCE Eligible kWh per
Residential Customer
359 Last Reported PCE Level (per kWh)$0.42
Average Monthly PCE Eligible kWh per
Community Facility Customer
90 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per person
5 PCE Eligible kWh vs Total kWh Sold 33.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,378,387 Fuel Used (Gallons)102,348
Non-Diesel kWh Generated 0 Fuel Cost $417,511
Purchased kWh 0 Average Price of Fuel $4.08
Total Purchased & Generated 1,378,387 Fuel Cost per kWh sold $0.52
Annual Non-Fuel Expenses $219,875
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.79
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 314,419 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
58.2%
Community Facility kWh Sold 25,736 Line Loss (%)39.3%
Other kWh Sold (Non-PCE)461,705 Fuel Efficiency (kWh per gallon of diesel)13.47
Total kWh Sold 801,860 PH Consumption as % of generation 2.5%
Powerhouse (PH) Consumption kWh 34,686
Total kWh Sold & PH Consumption 836,546
Comments
Provides power to Lower Kalskag via intertie
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 175 of 181
Venetie PCE
Utility: VENETIE VILLAGE ELECTRIC
Reporting Period: 07/01/12..06/30/13
Community Population 181
Last Reported Month June
No. of Monthly Payments Made 10
Residential Customers 88
Community Facility Customers 5
Other Customers (Non-PCE)16
Fiscal Year PCE Payments $119,730
PCE Statistical Data
PCE Eligible kWh - Residential Customers 168,952 Average Annual PCE Payment per Eligible
Customer
$1,287
PCE Eligible kWh - Community Facility
Customers
58,384 Average PCE Payment per Eligible kWh $0.53
Total PCE Eligible kWh 227,336 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.90
Average Monthly PCE Eligible kWh per
Residential Customer
192 Last Reported PCE Level (per kWh)$0.52
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,168 Effective Residential Rate (per kWh)$0.38
Average Monthly PCE Eligible Community
Facility kWh per person
32 PCE Eligible kWh vs Total kWh Sold 43.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 632,301 Fuel Used (Gallons)58,002
Non-Diesel kWh Generated 0 Fuel Cost $324,058
Purchased kWh 0 Average Price of Fuel $5.59
Total Purchased & Generated 632,301 Fuel Cost per kWh sold $0.63
Annual Non-Fuel Expenses $64,110
Non-Fuel Expense per kWh sold $0.12
Total Expense per kWh sold $0.75
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 183,288 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
81.9%
Community Facility kWh Sold 79,424 Line Loss (%)14.5%
Other kWh Sold (Non-PCE)254,878 Fuel Efficiency (kWh per gallon of diesel)10.90
Total kWh Sold 517,590 PH Consumption as % of generation 3.6%
Powerhouse (PH) Consumption kWh 22,817
Total kWh Sold & PH Consumption 540,407
Comments
Only 10 Months Reported; Jul-Aug not submitted
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 176 of 181
Wainwright PCE
Utility: NORTH SLOPE BOROUGH
Reporting Period: 07/01/12..06/30/13
Community Population 572
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 142
Community Facility Customers 3
Other Customers (Non-PCE)74
Fiscal Year PCE Payments $11,838
PCE Statistical Data
PCE Eligible kWh - Residential Customers 386,775 Average Annual PCE Payment per Eligible
Customer
$82
PCE Eligible kWh - Community Facility
Customers
75,765 Average PCE Payment per Eligible kWh $0.03
Total PCE Eligible kWh 462,540 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.15
Average Monthly PCE Eligible kWh per
Residential Customer
227 Last Reported PCE Level (per kWh)$0.01
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,105 Effective Residential Rate (per kWh)$0.14
Average Monthly PCE Eligible Community
Facility kWh per person
11 PCE Eligible kWh vs Total kWh Sold 8.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 6,656,991 Fuel Used (Gallons)469,420
Non-Diesel kWh Generated 0 Fuel Cost $1,853,769
Purchased kWh 0 Average Price of Fuel $3.95
Total Purchased & Generated 6,656,991 Fuel Cost per kWh sold $0.33
Annual Non-Fuel Expenses $783,611
Non-Fuel Expense per kWh sold $0.14
Total Expense per kWh sold $0.47
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,186,775 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
85.0%
Community Facility kWh Sold 75,765 Line Loss (%)9.3%
Other kWh Sold (Non-PCE)4,395,147 Fuel Efficiency (kWh per gallon of diesel)14.18
Total kWh Sold 5,657,687 PH Consumption as % of generation 5.7%
Powerhouse (PH) Consumption kWh 381,315
Total kWh Sold & PH Consumption 6,039,002
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 177 of 181
Wales PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/12..06/30/13
Community Population 154
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 49
Community Facility Customers 8
Other Customers (Non-PCE)17
Fiscal Year PCE Payments $101,428
PCE Statistical Data
PCE Eligible kWh - Residential Customers 160,611 Average Annual PCE Payment per Eligible
Customer
$1,779
PCE Eligible kWh - Community Facility
Customers
62,863 Average PCE Payment per Eligible kWh $0.45
Total PCE Eligible kWh 223,474 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.69
Average Monthly PCE Eligible kWh per
Residential Customer
273 Last Reported PCE Level (per kWh)$0.49
Average Monthly PCE Eligible kWh per
Community Facility Customer
655 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per person
34 PCE Eligible kWh vs Total kWh Sold 39.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 631,893 Fuel Used (Gallons)48,537
Non-Diesel kWh Generated 0 Fuel Cost $204,359
Purchased kWh 0 Average Price of Fuel $4.21
Total Purchased & Generated 631,893 Fuel Cost per kWh sold $0.36
Annual Non-Fuel Expenses $154,171
Non-Fuel Expense per kWh sold $0.27
Total Expense per kWh sold $0.64
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 231,403 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
89.0%
Community Facility kWh Sold 69,663 Line Loss (%)7.3%
Other kWh Sold (Non-PCE)261,177 Fuel Efficiency (kWh per gallon of diesel)13.02
Total kWh Sold 562,243 PH Consumption as % of generation 3.8%
Powerhouse (PH) Consumption kWh 23,827
Total kWh Sold & PH Consumption 586,070
Comments
Oct,Nov,Feb,May reported generation < sales
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 178 of 181
Whale Pass PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/12..06/30/13
Community Population 31
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 66
Community Facility Customers 2
Other Customers (Non-PCE)11
Fiscal Year PCE Payments $61,028
PCE Statistical Data
PCE Eligible kWh - Residential Customers 142,875 Average Annual PCE Payment per Eligible
Customer
$897
PCE Eligible kWh - Community Facility
Customers
6,633 Average PCE Payment per Eligible kWh $0.41
Total PCE Eligible kWh 149,508 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.59
Average Monthly PCE Eligible kWh per
Residential Customer
180 Last Reported PCE Level (per kWh)$0.37
Average Monthly PCE Eligible kWh per
Community Facility Customer
276 Effective Residential Rate (per kWh)$0.21
Average Monthly PCE Eligible Community
Facility kWh per person
18 PCE Eligible kWh vs Total kWh Sold 57.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 294,400 Fuel Used (Gallons)25,217
Non-Diesel kWh Generated 0 Fuel Cost $102,988
Purchased kWh 0 Average Price of Fuel $4.08
Total Purchased & Generated 294,400 Fuel Cost per kWh sold $0.39
Annual Non-Fuel Expenses $67,957
Non-Fuel Expense per kWh sold $0.26
Total Expense per kWh sold $0.65
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 174,145 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
89.1%
Community Facility kWh Sold 6,633 Line Loss (%)6.9%
Other kWh Sold (Non-PCE)81,603 Fuel Efficiency (kWh per gallon of diesel)11.67
Total kWh Sold 262,381 PH Consumption as % of generation 3.9%
Powerhouse (PH) Consumption kWh 11,620
Total kWh Sold & PH Consumption 274,001
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 179 of 181
White Mountain PCE
Utility: CITY OF WHITE MOUNTAIN
Reporting Period: 07/01/12..06/30/13
Community Population 199
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 67
Community Facility Customers 9
Other Customers (Non-PCE)25
Fiscal Year PCE Payments $107,517
PCE Statistical Data
PCE Eligible kWh - Residential Customers 229,731 Average Annual PCE Payment per Eligible
Customer
$1,415
PCE Eligible kWh - Community Facility
Customers
115,336 Average PCE Payment per Eligible kWh $0.31
Total PCE Eligible kWh 345,067 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.62
Average Monthly PCE Eligible kWh per
Residential Customer
286 Last Reported PCE Level (per kWh)$0.31
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,068 Effective Residential Rate (per kWh)$0.31
Average Monthly PCE Eligible Community
Facility kWh per person
48 PCE Eligible kWh vs Total kWh Sold 48.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 784,500 Fuel Used (Gallons)65,284
Non-Diesel kWh Generated 0 Fuel Cost $234,114
Purchased kWh 0 Average Price of Fuel $3.59
Total Purchased & Generated 784,500 Fuel Cost per kWh sold $0.33
Annual Non-Fuel Expenses $122,482
Non-Fuel Expense per kWh sold $0.17
Total Expense per kWh sold $0.51
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 254,533 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
89.9%
Community Facility kWh Sold 121,896 Line Loss (%)5.4%
Other kWh Sold (Non-PCE)328,512 Fuel Efficiency (kWh per gallon of diesel)12.02
Total kWh Sold 704,941 PH Consumption as % of generation 4.7%
Powerhouse (PH) Consumption kWh 37,012
Total kWh Sold & PH Consumption 741,953
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 180 of 181
Yakutat PCE
Utility: YAKUTAT POWER INC.
Reporting Period: 07/01/12..06/30/13
Community Population 656
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 293
Community Facility Customers 26
Other Customers (Non-PCE)127
Fiscal Year PCE Payments $490,324
PCE Statistical Data
PCE Eligible kWh - Residential Customers 1,096,419 Average Annual PCE Payment per Eligible
Customer
$1,537
PCE Eligible kWh - Community Facility
Customers
354,273 Average PCE Payment per Eligible kWh $0.34
Total PCE Eligible kWh 1,450,692 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.52
Average Monthly PCE Eligible kWh per
Residential Customer
312 Last Reported PCE Level (per kWh)$0.33
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,135 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per person
45 PCE Eligible kWh vs Total kWh Sold 26.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 6,317,267 Fuel Used (Gallons)422,124
Non-Diesel kWh Generated 0 Fuel Cost $1,838,569
Purchased kWh 0 Average Price of Fuel $4.36
Total Purchased & Generated 6,317,267 Fuel Cost per kWh sold $0.33
Annual Non-Fuel Expenses $983,560
Non-Fuel Expense per kWh sold $0.18
Total Expense per kWh sold $0.51
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,427,000 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
87.9%
Community Facility kWh Sold 401,381 Line Loss (%)9.7%
Other kWh Sold (Non-PCE)3,727,519 Fuel Efficiency (kWh per gallon of diesel)14.97
Total kWh Sold 5,555,900 PH Consumption as % of generation 2.4%
Powerhouse (PH) Consumption kWh 150,489
Total kWh Sold & PH Consumption 5,706,389
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 181 of 181