HomeMy WebLinkAboutFY18 PCE Annual Community Summaries 2018-PCEPOWER COST
EQUALIZATION
PROGRAM
STATISTICAL REPORT
FY2018
Akiachak
POWER COST EQUALIZATION PROGRAM
Statistical Data by Community
Reporting Period: 07/01/17..06/30/18
Table of Contents
Program Highlights…………………………………………………………………………...…………………7
Fiscal Year 2017 vs. 2018…………………………………………………………………………...………8
Historical Trends Fiscal Years 2009 ‐ 2018……………………………………………………………9
List of Participating Utilities/Communities………………………………………………………… 10
Map of Participating Utilities/Communities…………………………………………………………11
Adak…………………………………………………………………………...…………………………….……… 12
Akhiok…………………………………………………………………………...…………………………….……13
Akiachak…………………………………………………………………………...…………………………….…14
Akiak…………………………………………………………………………...…………………………….………15
Akutan…………………………………………………………………………...…………………………….……16
Alakanuk…………………………………………………………………………...…………………………….…17
Allakaket; Alatna…………………………………………………………………………...……………………18
Ambler…………………………………………………………………………...…………………………….……19
Anaktuvuk Pass…………………………………………………………………………...………………………20
Angoon…………………………………………………………………………...…………………………….……21
Aniak…………………………………………………………………………...…………………………….………22
Anvik…………………………………………………………………………...…………………………….………23
Arctic Village…………………………………………………………………………...…………………………24
Atka…………………………………………………………………………...…………………………….…………25
Atmautluak…………………………………………………………………………...……………………………26
Atqasuk…………………………………………………………………………...…………………………….……27
Beaver…………………………………………………………………………...…………………………….……28
Bethel; Oscarville…………………………………………………………………………...……………………29
Bettles; Evansville…………………………………………………………………………...…………………30
Birch Creek…………………………………………………………………………...……………………………31
Brevig Mission…………………………………………………………………………...………………………32
Buckland…………………………………………………………………………...…………………………….…33
Central…………………………………………………………………………...…………………………….……34
Chalkyitsik…………………………………………………………………………...…………………………… 35
Chefornak…………………………………………………………………………...…………………………….36
Chenega Bay…………………………………………………………………………...…………………………37
Chevak…………………………………………………………………………...…………………………….……38
Chignik Lagoon…………………………………………………………………………...………………………39
Chignik Lake…………………………………………………………………………...…………………………40
Chignik…………………………………………………………………………...…………………………….……41
Page 2 of 191
POWER COST EQUALIZATION PROGRAM
Statistical Data by Community
Reporting Period: 07/01/17..06/30/18
Table of Contents
Chilkat Valley…………………………………………………………………………...…………………………42
Chistochina…………………………………………………………………………...……………………………43
Chitina…………………………………………………………………………...…………………………….……44
Chuathbaluk…………………………………………………………………………...…………………………45
Circle…………………………………………………………………………...…………………………….………46
Clarks Point…………………………………………………………………………...……………………………47
Coffman Cove…………………………………………………………………………...……………………… 48
Cold Bay…………………………………………………………………………...…………………………….…49
Cordova…………………………………………………………………………...…………………………….… 50
Craig…………………………………………………………………………...…………………………….……… 51
Crooked Creek…………………………………………………………………………...………………………52
Deering…………………………………………………………………………...…………………………….……53
Dillingham; Aleknagik…………………………………………………………………………...……………54
Diomede…………………………………………………………………………...…………………………….…55
Dot Lake; Dot Lake Village…………………………………………………………………………...…… 56
Eagle; Eagle Village…………………………………………………………………………...…………………57
Eek…………………………………………………………………………...…………………………….…………58
Egegik…………………………………………………………………………...…………………………….………59
Ekwok…………………………………………………………………………...…………………………….………60
Elfin Cove…………………………………………………………………………...…………………………….…61
Elim…………………………………………………………………………...…………………………….…………62
Emmonak…………………………………………………………………………...……………………………. 63
False Pass…………………………………………………………………………...……………………………. 64
Fort Yukon…………………………………………………………………………...……………………………65
Galena…………………………………………………………………………...…………………………….……66
Gambell…………………………………………………………………………...…………………………….… 67
Golovin…………………………………………………………………………...…………………………….……68
Goodnews Bay…………………………………………………………………………...………………………69
Grayling…………………………………………………………………………...…………………………….……70
Gustavus…………………………………………………………………………...…………………………….…71
Haines; Covenant Life…………………………………………………………………………...……………72
Healy Lake…………………………………………………………………………...…………………………… 73
Hollis…………………………………………………………………………...…………………………….………74
Holy Cross…………………………………………………………………………...…………………………….75
Hoonah…………………………………………………………………………...…………………………….……76
Hooper Bay…………………………………………………………………………...……………………………77
Hughes…………………………………………………………………………...…………………………….……78
Huslia…………………………………………………………………………...…………………………….………79
Hydaburg…………………………………………………………………………...…………………………….…80
Igiugig…………………………………………………………………………...…………………………….………81
Iliamna Newhalen Nondalton…………………………………………………………………………...…82
Page 3 of 191
POWER COST EQUALIZATION PROGRAM
Statistical Data by Community
Reporting Period: 07/01/17..06/30/18
Table of Contents
Kake…………………………………………………………………………...…………………………….…………83
Kaktovik…………………………………………………………………………...…………………………….…84
Kaltag…………………………………………………………………………...…………………………….………85
Karluk…………………………………………………………………………...…………………………….………86
Kasigluk…………………………………………………………………………...…………………………….……87
Kiana…………………………………………………………………………...…………………………….………88
King Cove…………………………………………………………………………...…………………………….…89
Kipnuk…………………………………………………………………………...…………………………….……90
Kivalina…………………………………………………………………………...…………………………….……91
Klawock…………………………………………………………………………...…………………………….……92
Klukwan…………………………………………………………………………...…………………………….… 93
Kobuk…………………………………………………………………………...…………………………….………94
Kokhanok…………………………………………………………………………...…………………………….…95
Koliganek…………………………………………………………………………...…………………………….…96
Kongiganak…………………………………………………………………………...……………………………97
Kotlik…………………………………………………………………………...…………………………….………98
Kotzebue…………………………………………………………………………...…………………………….…99
Koyuk…………………………………………………………………………...…………………………….………100
Koyukuk…………………………………………………………………………...…………………………….…101
Kwethluk…………………………………………………………………………...…………………………….…102
Kwigillingok…………………………………………………………………………...……………………………103
Larsen Bay…………………………………………………………………………...…………………………… 104
Levelock…………………………………………………………………………...…………………………….…105
Lime Village…………………………………………………………………………...……………………………106
Lower Kalskag…………………………………………………………………………...……………………… 107
Manley Hot Springs…………………………………………………………………………...………………108
Manokotak…………………………………………………………………………...……………………………109
Marshall…………………………………………………………………………...…………………………….…110
McGrath…………………………………………………………………………...…………………………….…111
Mekoryuk…………………………………………………………………………...……………………………. 112
Mentasta…………………………………………………………………………...…………………………….…113
Minto…………………………………………………………………………...…………………………….………114
Mt. Village…………………………………………………………………………...…………………………… 115
Naknek;S.Naknek;Kng Slmn…………………………………………………………………………...……116
Napakiak…………………………………………………………………………...…………………………….…117
Napaskiak…………………………………………………………………………...……………………………. 118
Naukati…………………………………………………………………………...…………………………….……119
Nelson Lagoon…………………………………………………………………………...………………………120
New Stuyahok…………………………………………………………………………...………………………121
Newtok…………………………………………………………………………...…………………………….……122
Nightmute…………………………………………………………………………...…………………………… 123
Page 4 of 191
POWER COST EQUALIZATION PROGRAM
Statistical Data by Community
Reporting Period: 07/01/17..06/30/18
Table of Contents
Nikolai…………………………………………………………………………...…………………………….……124
Nikolski…………………………………………………………………………...…………………………….……125
Noatak…………………………………………………………………………...…………………………….……126
Nome…………………………………………………………………………...…………………………….………127
Noorvik…………………………………………………………………………...…………………………….……128
Northway; Northway Village…………………………………………………………………………...…129
Nuiqsut…………………………………………………………………………...…………………………….……130
Nulato…………………………………………………………………………...…………………………….…… 131
Nunam Iqua…………………………………………………………………………...……………………………132
Nunapitchuk…………………………………………………………………………...…………………………133
Old Harbor…………………………………………………………………………...……………………………134
Ouzinkie…………………………………………………………………………...…………………………….…135
Pedro Bay…………………………………………………………………………...……………………………. 136
Pilot Point…………………………………………………………………………...…………………………….137
Pilot Station…………………………………………………………………………...……………………………138
Pitkas Point…………………………………………………………………………...……………………………139
Platinum…………………………………………………………………………...…………………………….…140
Point Hope…………………………………………………………………………...……………………………141
Point Lay…………………………………………………………………………...…………………………….…142
Port Alsworth…………………………………………………………………………...…………………………143
Port Heiden…………………………………………………………………………...……………………………144
Quinhagak…………………………………………………………………………...…………………………… 145
Rampart…………………………………………………………………………...…………………………….…146
Red Devil…………………………………………………………………………...…………………………….…147
Ruby…………………………………………………………………………...…………………………….……… 148
Russian Mission…………………………………………………………………………...…………………… 149
Sand Point…………………………………………………………………………...…………………………… 150
Savoonga…………………………………………………………………………...…………………………….…151
Scammon Bay…………………………………………………………………………...……………………… 152
Selawik…………………………………………………………………………...…………………………….……153
Shageluk…………………………………………………………………………...…………………………….…154
Shaktoolik…………………………………………………………………………...…………………………….155
Shishmaref…………………………………………………………………………...……………………………156
Shungnak…………………………………………………………………………...…………………………….…157
Skagway…………………………………………………………………………...…………………………….…158
Slana…………………………………………………………………………...…………………………….………159
Sleetmute…………………………………………………………………………...…………………………….160
St. George…………………………………………………………………………...…………………………….161
St. Mary's; Andreafsky…………………………………………………………………………...……………162
St. Michael…………………………………………………………………………...……………………………163
St. Paul…………………………………………………………………………...…………………………….……164
Page 5 of 191
POWER COST EQUALIZATION PROGRAM
Statistical Data by Community
Reporting Period: 07/01/17..06/30/18
Table of Contents
Stebbins…………………………………………………………………………...…………………………….…165
Stevens Village…………………………………………………………………………...………………………166
Stony River…………………………………………………………………………...……………………………167
Takotna…………………………………………………………………………...…………………………….……168
Tanana…………………………………………………………………………...…………………………….……169
Tatitlek…………………………………………………………………………...…………………………….……170
Teller…………………………………………………………………………...…………………………….………171
Tenakee Springs…………………………………………………………………………...……………………172
Tetlin…………………………………………………………………………...…………………………….………173
Thorne Bay; Kasaan…………………………………………………………………………...………………174
Togiak…………………………………………………………………………...…………………………….………175
Tok; Tanacross…………………………………………………………………………...………………………176
Toksook Bay…………………………………………………………………………...…………………………177
Tuluksak…………………………………………………………………………...…………………………….…178
Tuntutuliak…………………………………………………………………………...……………………………179
Tununak…………………………………………………………………………...…………………………….…180
Twin Hills…………………………………………………………………………...…………………………….…181
Unalakleet…………………………………………………………………………...…………………………… 182
Unalaska…………………………………………………………………………...…………………………….…183
Upper Kalskag…………………………………………………………………………...……………………… 184
Venetie…………………………………………………………………………...…………………………….……185
Wainwright…………………………………………………………………………...……………………………186
Wales…………………………………………………………………………...…………………………….………187
Whale Pass…………………………………………………………………………...……………………………188
White Mountain…………………………………………………………………………...……………………189
Yakutat…………………………………………………………………………...…………………………….……190
Page 6 of 191
Page 7 of 191
HIGHLIGHTS OF THE POWER COST EQUALIZATION PROGRAM
Eligibility
Utility
An electric utility participating in the Power Cost Equalization Program (PCE) must:
a) provide electric service to the public for compensation; b) during calendar year 1983, had
less than 7,500 megawatt hours of residential consumption or less than 15,000 megawatt
hours if two or more communities were served; and c) during calendar year 1984, the utility
has used diesel-fired generators to produce more than 75% of its electrical consumption.
Customers
Customer eligibility is based on actual power purchased. State and federal offices/facilities,
commercial customers and public schools are excluded from PCE. Residential customers
are eligible for PCE credit up to 500 kilowatt-hours (kWh/s) per month. Community
facilities, as a group, can receive PCE credit for up to 70 kilowatt-hours per month multiplied
by the number of residents in a community.
Formula Used to determine PCE level/kWh for a utility:
Formula: 95% of the eligible costs per kWh between
17.58 cents/kWh, “the floor”
and $1.00/kWh, “the ceiling”.
Costs below 17.58 cents/kWh and above $1.00/kWh are not eligible for PCE.
If the eligible costs are $1.00/kWh or more, the maximum PCE level is 78.30 cents/kWh
($1.00 – 17.58 cents = 82.42 cents x 95% = 78.30 cents).
A participating utility must meet generation efficiency and line loss standards; otherwise the
PCE level is reduced to reflect those standards.
Process
The Regulatory Commission of Alaska (RCA)
RCA determines the PCE level per kWh for each utility. Two categories of costs are used
in determining the PCE level: a) fuel expenses: the cost of fuel, including transportation of
fuel; and b) non-fuel expenses: salaries, insurance, taxes, power plant parts and supplies,
interest and other reasonable costs.
The Alaska Energy Authority (AEA)
Eligible utilities submit monthly reports to AEA that document the eligible power sold and
PCE credits applied to eligible customers’ bills. AEA calculates the amount of PCE on a
monthly basis and issues payment to the utility. AEA verifies the eligibility of customers and
of community facilities. In addition, AEA calculates the required pro-rated PCE levels based
on available funds.
Authority
PCE is governed by Alaska Statutes 42.45.110-170, and by the Alaska Administrative Code
3 AAC 107.200-270 and 3 AAC 52.600-690.
Page 8 of 191
POWER COST EQUALIZATION PROGRAM STATISTICS
FISCAL YR FISCAL YR % CHANGE
See (6)
2017 2018 2018‐2017
Participation Statistics
Population Served 83,850 83,400 ‐0.5%
Communities Served 194 194 0.0%
Participating Utilities 89 89 0.0%
Total Residential Customers (7) 27,857 28,365 1.8%
Total Community Facilities Customers (7) 2,067 2,090 1.1%
Total Customers (Residential & Community Facilities) (1) (7) 29,924 30,455 1.8%
Production Statistics
Total Diesel Generation (kWh) 409,314,376 400,342,759 ‐2.2%
Total "Other" (Hydro/Wind/Solar/Natural Gas) Generation (kWh) 50,063,264 53,215,323 6.3%
Total Purchased Power (kWh) 52,252,672 52,097,365 ‐0.3%
Total kWh Sold (All Customers) (2) 462,997,827 458,734,104 ‐0.9%
PCE Eligible Residential kWh 97,751,041 96,597,391 ‐1.2%
PCE Eligible Community kWh 35,747,251 34,928,900 ‐2.3%
Total PCE Eligible ‐ Community Facilities & Residential 133,498,292 131,526,291 ‐1.5%
Total PCE Eligible kWh Shown as Percent of Total kWh Sold 29% 21%‐27.0%
Average Monthly PCE Eligible kWh ‐ Residential Customers (3) 292284‐2.9%
Average Monthly PCE Eligible kWh ‐ Community Facilities (3) 1,441 1,393 ‐3.4%
Average Monthly PCE Eligible kWh ‐ Community Facilities / Per Resident (3) 36 35 ‐1.8%
Financial Statistics
Average Price of Fuel Oil ($/gallon) 2.6617$ 2.8569$ 7.3%
Total Fuel Oil Consumed (gallons) 28,838,704 28,638,535 ‐0.7%
Total Cost of Fuel Oil Purchased by the Utilities ($) 76,759,457$ 76,137,419$ ‐0.8%
Total Non‐Fuel Expenses ($) (6) 85,141,895$ 89,505,362$ 5.1%
Non‐Fuel Expenses per Total kWh Sold ($) (6) 0.1839$ 0.1951$ 6.1%
Total Operating Costs per kWh ($) Sold (4) 0.3497$ 0.3611$ 3.3%
PCE Legislative Funding Appropriations for Utility Payments 40,000,000$ 32,355,000$ ‐19.1%
Total Monthly Reports/PCE Reimbursements to Utilities Processed (5) 26,099,807$ 26,182,235$ 0.3%
(1) Assumes all customers were eligible to receive PCE credit.
(2) Value reduced by 577,169 in FY17 and 634,910 in FY18 to eliminate double counting of kWh's
where power is sold/purchased between utilities participating in the PCE Program.
(3) Calculation assumes all customers were eligible to receive twelve (12) months of PCE credit.
(4) "Operating" costs include both fuel and non-fuel expenses.
(5) During FY17 and FY18 PCE payments were made at a 100% level for all 12 months.
(6) Net change between years is partially attributable to incomplete reporting by utilties
(7) Total Customers represents the number of customers reported by the utility for the last reported month.
Page 9 of 191 POWER COST EQUALIZATION PROGRAMHISTORICAL TRENDSFiscal Year 2009 - 20182009 2010 2011 2012 2013 2014 2015 2016 2017 2018PARTICIPATIONParticipating Utilities 85 84 83 87 88 87 86 88 89 89Communities Served 184 183 183 188 190 190 190 191 194 194Population Served 77,518 78,431 77,341 79,644 81,693 82,427 81,969 82,986 83,850 83,400PCE ELIGIBLE CUSTOMERSResidential 26,562 26,794 26,753 27,402 27,795 27,716 27,893 28,035 27,857 28,365Community Facilities 1,903 1,899 1,888 1,919 1,900 1,889 1,850 2,056 2,067 2,090Total Customers 28,465 28,693 28,641 29,321 29,695 29,605 29,743 30,09129,924 30,455FUNDINGAppropriations ($) $38,500,000 $37,660,000 $36,000,000 $39,150,000 $40,100,000 $41,006,000 $41,000,000 $41,000,000 $40,000,000 $32,355,000Disbursements ($) $37,029,584 $30,627,339 $31,810,803 $39,059,864 $39,715,618 $39,571,659 $37,379,742 $31,042,569 $26,099,807 $26,182,235Disbursements/Customer ($) $1,301 $1,067 $1,111 $1,332 $1,337 $1,337 $1,257 $1,032 $872 $860Funding Level 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%CONSUMPTIONTotal MWh Sold (MWH) 435,580 422,159 437,266 459,056 463,573 452,751 450,852 447,333 462,998 458,734PCE Eligible MWh Residential 91,941 91,484 93,175 96,666 97,102 95,990 96,453 94,816 97,751 96,597Avg. PCE Eligible kWh/Month/Residential Cust 288 285 290 294 291 289 288 282 292 284PCE Eligible MWh Community Facilities 32,142 31,459 33,116 34,750 34,743 33,409 32,795 34,357 35,747 34,928Elig. kWh/Month/Capita, Community Facilities 35.0 33.0 36.0 36.0 35.0 34.0 33.3 35.0 36.0 35.0Total PCE Eligible MWh 124,083 122,943 126,291 131,417 131,845 129,414 129,248 129,173 133,498 131,526Eligible kWh/Month/Cust, Total Customers 363 357 367 374 370 364 362 358 372 360COSTSAverage Price of Fuel Oil ($/gallon) $3.97 $3.28 $3.45 $4.02 $4.21 $4.21 $3.97 $3.24 $2.66 $2.86Total Gallons of Fuel Oil Consumed 29,351,396 27,597,323 28,159,847 29,204,577 28,957,490 27,919,599 27,191,149 26,865,206 28,838,704 28,638,535Total Cost of Fuel Oil ($) $116,446,822 $90,555,298 $97,042,004 $117,313,926 $121,707,897 $117,483,188 $107,842,372 $87,102,302 $76,759,457 $76,137,419Total Non-Fuel Costs ($) $55,475,597 $67,018,467 $60,012,748 $69,554,141 $79,772,882 $73,336,386 $76,036,533 $82,964,017 $85,141,895 $89,505,362FINANCIAL RATIOSNon-Fuel Costs Per Total kWh Sold 0.1274$ 0.1588$ 0.1372$ 0.1515$ 0.1721$ 0.1620$ 0.1687$ 0.1855$ 0.1839$ 0.1770$ Total Operating Costs Per Total kWh Sold 0.3939$ 0.3733$ 0.3592$ 0.4071$ 0.4346$ 0.4215$ 0.4078$ 0.3802$ 0.3497$ 0.3276$ RATESAvg. PCE per Eligible kWh Res. & Comm Facility ($/kWh) 0.2984$ 0.2491$ 0.2519$ 0.2972$ 0.3012$ 0.3058$ 0.2892$ 0.2403$ 0.1955$ 0.3021$ Weighted Avg. Residential Rate (Before PCE Paid) 0.5195$ 0.4677$ 0.4756$ 0.5131$ 0.4973$ 0.5005$ 0.4915$ 0.4541$ 0.4270$ 0.4226$ Weighted Avg. Residential PCE Rate (Amount PCE pays) 0.3064$ 0.2596$ 0.2592$ 0.3044$ 0.3064$ 0.3108$ 0.2919$ 0.2432$ 0.1983$ 0.1987$ Weighted Avg. Residential Effective Rate (1)0.2131$ 0.2081$ 0.2164$ 0.2087$ 0.1909$ 0.1897$ 0.1996$ 0.2109$ 0.2287$ 0.2239$ (1) Amount customers pay for first 500 kWh/month.
Birch Creek Electric Napaskiak Electric Utility
Buckland, City of Naterkaq Light Plant
Chalkyitsik Village Council Chefornak
Chenega IRA Village Council Nelson Lagoon Electrical Cooperative
Chignik, City of New Koliganek Village Council
Allakaket / Alatna Hydaburg Chignik Lagoon Power Utility Koliganek
Bettles / Evansville Klawock Chignik Lake Electric Nikolai, City of
Chistochina Mentasta Chitina Electric Inc.Nome Joint Utility System
Coffman Cove Naukati Circle Electric Utility North Slope Borough
Craig Northway / Northway Village Clarks Point Village Council Anaktuvuk Pass Point Hope
Dot Lake / Dot Lake Village Skagway Cordova Electric Co-op Atqasuk Point Lay
Eagle / Eagle Village Slana Diomede Joint Utilities Kaktovik Wainwright
Gustavus Tetlin Egegik Light and Power Nuiqsut
Haines / Covenant Life Thorne Bay / Kassan Elfin Cove Utility Commission Nunam Iqua Electric Company
Healy Tok / Tanacross False Pass, City of Nushagak Electric Cooperative
Hollis Whale Pass Galena, City of Aleknagik / Dillingham
Alaska Village Electric Cooperative G & K Inc.Ouzinkie, City of
Alakanuk Nightmute Cold Bay Pedro Bay Village Council
Ambler Noatak Gold Country Energy Pilot Point Electrical
Anvik Noorvik Central Platinum Commercial Company
Bethel / Oscarville Nulato Golovin Power Utilities Port Heiden Utilities
Brevig Mission Nunapitchuk Gwitchyaa Zhee Utilities Puvurnaq Power Company
Chevak Old Harbor Fort Yukon Kongiganak
Eek Pilot Station Hughes Power & Light Rampart Village Council Electric
Ekwok Pitka's Point Igiugig Electric Company Ruby, City of
Elim Quinhagak I-N-N Electric Cooperative St. George, City of
Emmonak Russian Mission Iliamna / Newhalen / Nondalton St. Paul Municipal Electric
Gambell Savoonga Inside Passage Electric Cooperative Stevens Village IRA Council
Goodnews Bay Scammon Bay Angoon Kake Takotna Community Assoc. Inc.
Grayling Selawik Chilkat Valley Klukwan Tanalian Electric Cooperative
Holy Cross Shageluk Hoonah Port Alsworth
Hooper Bay Shaktoolik Ipnatchiaq Electric Company Tanana Power Company Inc.
Huslia Shishmaref Deering Tatitlek Village IRA Council
Kaltag Shungnak King Cove, City of TDX Adak Generating LLC
Kasigluk St. Mary's / Andreafsky Kipnuk Light Plant Adak
Kiana St. Michael Kokhanok Village Council TDX Corporation
Kivalina Stebbins Kotzebue Electric Association Sand Point
Kobuk Teller Koyukuk, City of TDX Manley Generating LLC
Kotlik Togiak Kwethluk Incorporated Manley Hot Springs
Koyuk Toksook Bay Kwigillingok IRA Council Tenakee Springs, City of
Lower Kalskag Tununak Larsen Bay Utility Company Tuluksak Traditional Power Utility
Marshall Upper Kalskag Levelock Electrical Coop Tuntutuliak Community Service Assoc.
Mekoryuk Wales Lime Village Electric Utility Twin Hills Village Council
Minto Yakutat Manokotak Power Company Umnak Power Company
Mt. Village McGrath Light & Power Nikolski
New Stuyahok Middle Kuskokwim Electric Unalakleet Valley Electrical Cooperative
Alutiiq Power Company Chuathbaluk Sleetmute Unalaska, City of
Karluk Crooked Creek Stony River Ungusrag Power Company
Aniak Light & Power Company Red Devil Newtok
Arctic Village Council Naknek Electric Venetie Village Electric
Atka, City of King Salmon White Mountain, City of
Atmautluak Joint Utilities Naknek / South Naknek
Beaver Joint Utilities Napakiak Ircinraq
FY18 PCE Program Participating Utilities
Akiachak Native Community
Akiak City Council
Alaska Power Company
Akhiok / Kaguyak Electric
Akutan Electric Utility
Page 10 of 191
Page 11 of 191
Adak PCE
Utility: TDX ADAK GENERATING LLC
Reporting Period: 07/01/17..06/30/18
Community Population 309
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 101
Community Facility Customers 7
Other Customers (Non‐PCE) 121
Fiscal Year PCE Payments $202,219
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 171,045 Average Annual PCE Payment per Eligible
Customer
$1,872
PCE Eligible kWh ‐ Community Facility
Customers
147,649 Average PCE Payment per Eligible kWh $0.63
Total PCE Eligible kWh 318,694 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.43
Average Monthly PCE Eligible kWh per
Residential Customer
141 Last Reported PCE Level (per kWh) $0.72
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,758 Effective Residential Rate (per kWh) $0.71
Average Monthly PCE Eligible Community
Facility kWh per Person
40 PCE Eligible kWh vs Total kWh Sold 25.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,017,190 Fuel Used (Gallons) 164,150
Non‐Diesel kWh Generated 0 Fuel Cost $630,951
Purchased kWh 0 Average Price of Fuel $3.84
Total Purchased & Generated 2,017,190 Fuel Cost per kWh sold $0.51
Annual Non‐Fuel Expenses $1,625,820
Non‐Fuel Expense per kWh Sold $1.31
Total Expense per kWh Sold $1.82
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 280,679 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
61.3%
Community Facility kWh Sold 220,926 Line Loss (%) 24.6%
Other kWh Sold (Non‐PCE) 735,913 Fuel Efficiency (kWh per Gallon of Diesel)12.29
Total kWh Sold 1,237,518 PH Consumption as % of Generation 14.1%
Powerhouse (PH) Consumption kWh 283,716
Total kWh Sold & PH Consumption 1,521,234
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 12 of 191
Akhiok PCE
Utility: AKHIOK/KAGUYAK ELECTRIC
Reporting Period: 07/01/17..06/30/18
Community Population 97
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 27
Community Facility Customers 8
Other Customers (Non‐PCE) 8
Fiscal Year PCE Payments $33,490
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 72,825 Average Annual PCE Payment per Eligible
Customer
$957
PCE Eligible kWh ‐ Community Facility
Customers
24,891 Average PCE Payment per Eligible kWh $0.34
Total PCE Eligible kWh 97,716 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.80
Average Monthly PCE Eligible kWh per
Residential Customer
225 Last Reported PCE Level (per kWh) $0.39
Average Monthly PCE Eligible kWh per
Community Facility Customer
259 Effective Residential Rate (per kWh) $0.41
Average Monthly PCE Eligible Community
Facility kWh per Person
21 PCE Eligible kWh vs Total kWh Sold 42.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 282,443 Fuel Used (Gallons) 29,345
Non‐Diesel kWh Generated 0 Fuel Cost $112,377
Purchased kWh 0 Average Price of Fuel $3.83
Total Purchased & Generated 282,443 Fuel Cost per kWh sold $0.48
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.48
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 84,308 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
82.4%
Community Facility kWh Sold 24,891 Line Loss (%) 13.9%
Other kWh Sold (Non‐PCE) 123,643 Fuel Efficiency (kWh per Gallon of Diesel)9.62
Total kWh Sold 232,842 PH Consumption as % of Generation 3.6%
Powerhouse (PH) Consumption kWh 10,274
Total kWh Sold & PH Consumption 243,116
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 13 of 191
Akiachak PCE
Utility: AKIACHAK NATIVE COMMUNITY
Reporting Period: 07/01/17..06/30/18
Community Population 701
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 191
Community Facility Customers 10
Other Customers (Non‐PCE) 29
Fiscal Year PCE Payments $204,942
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 554,669 Average Annual PCE Payment per Eligible
Customer
$1,020
PCE Eligible kWh ‐ Community Facility
Customers
239,388 Average PCE Payment per Eligible kWh $0.26
Total PCE Eligible kWh 794,057 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.60
Average Monthly PCE Eligible kWh per
Residential Customer
242 Last Reported PCE Level (per kWh) $0.26
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,995 Effective Residential Rate (per kWh) $0.34
Average Monthly PCE Eligible Community
Facility kWh per Person
28 PCE Eligible kWh vs Total kWh Sold 44.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,933,185 Fuel Used (Gallons) 135,059
Non‐Diesel kWh Generated 0 Fuel Cost $402,295
Purchased kWh 0 Average Price of Fuel $2.98
Total Purchased & Generated 1,933,185 Fuel Cost per kWh sold $0.23
Annual Non‐Fuel Expenses $342,769
Non‐Fuel Expense per kWh Sold $0.19
Total Expense per kWh Sold $0.42
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 669,550 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
91.7%
Community Facility kWh Sold 242,017 Line Loss (%) 6.5%
Other kWh Sold (Non‐PCE) 861,762 Fuel Efficiency (kWh per Gallon of Diesel)14.31
Total kWh Sold 1,773,329 PH Consumption as % of Generation 1.8%
Powerhouse (PH) Consumption kWh 34,335
Total kWh Sold & PH Consumption 1,807,664
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 14 of 191
Akiak PCE
Utility: AKIAK CITY COUNCIL
Reporting Period: 07/01/17..06/30/18
Community Population 389
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 94
Community Facility Customers 8
Other Customers (Non‐PCE) 34
Fiscal Year PCE Payments $87,868
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 334,744 Average Annual PCE Payment per Eligible
Customer
$861
PCE Eligible kWh ‐ Community Facility
Customers
52,157 Average PCE Payment per Eligible kWh $0.23
Total PCE Eligible kWh 386,901 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.53
Average Monthly PCE Eligible kWh per
Residential Customer
297 Last Reported PCE Level (per kWh) $0.24
Average Monthly PCE Eligible kWh per
Community Facility Customer
543 Effective Residential Rate (per kWh) $0.29
Average Monthly PCE Eligible Community
Facility kWh per Person
11 PCE Eligible kWh vs Total kWh Sold 36.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,212,912 Fuel Used (Gallons) 93,752
Non‐Diesel kWh Generated 0 Fuel Cost $299,024
Purchased kWh 0 Average Price of Fuel $3.19
Total Purchased & Generated 1,212,912 Fuel Cost per kWh sold $0.28
Annual Non‐Fuel Expenses $169,284
Non‐Fuel Expense per kWh Sold $0.16
Total Expense per kWh Sold $0.44
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 356,833 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
87.6%
Community Facility kWh Sold 160,632 Line Loss (%) 9.5%
Other kWh Sold (Non‐PCE) 545,437 Fuel Efficiency (kWh per Gallon of Diesel)12.94
Total kWh Sold 1,062,902 PH Consumption as % of Generation 2.8%
Powerhouse (PH) Consumption kWh 34,320
Total kWh Sold & PH Consumption 1,097,222
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 15 of 191
Akutan PCE
Utility: CITY OF AKUTAN
Reporting Period: 07/01/17..06/30/18
Community Population 1000
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 40
Community Facility Customers 11
Other Customers (Non‐PCE) 24
Fiscal Year PCE Payments $202,741
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 152,996 Average Annual PCE Payment per Eligible
Customer
$3,975
PCE Eligible kWh ‐ Community Facility
Customers
108,875 Average PCE Payment per Eligible kWh $0.77
Total PCE Eligible kWh 261,871 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.95
Average Monthly PCE Eligible kWh per
Residential Customer
319 Last Reported PCE Level (per kWh) $0.77
Average Monthly PCE Eligible kWh per
Community Facility Customer
825 Effective Residential Rate (per kWh) $0.18
Average Monthly PCE Eligible Community
Facility kWh per Person
9 PCE Eligible kWh vs Total kWh Sold 54.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 477,411 Fuel Used (Gallons) 38,892
Non‐Diesel kWh Generated 134,170 Fuel Cost $100,456
Purchased kWh 0 Average Price of Fuel $2.58
Total Purchased & Generated 611,581 Fuel Cost per kWh sold $0.21
Annual Non‐Fuel Expenses $304,234
Non‐Fuel Expense per kWh Sold $0.64
Total Expense per kWh Sold $0.85
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 178,597 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
78.0%
Community Facility kWh Sold 108,875 Line Loss (%) 15.6%
Other kWh Sold (Non‐PCE) 189,396 Fuel Efficiency (kWh per Gallon of Diesel)12.28
Total kWh Sold 476,868 PH Consumption as % of Generation 6.4%
Powerhouse (PH) Consumption kWh 39,219
Total kWh Sold & PH Consumption 516,087
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 16 of 191
Alakanuk PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 707
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 155
Community Facility Customers 10
Other Customers (Non‐PCE) 36
Fiscal Year PCE Payments $227,045
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 656,208 Average Annual PCE Payment per Eligible
Customer
$1,376
PCE Eligible kWh ‐ Community Facility
Customers
255,474 Average PCE Payment per Eligible kWh $0.25
Total PCE Eligible kWh 911,682 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.50
Average Monthly PCE Eligible kWh per
Residential Customer
353 Last Reported PCE Level (per kWh) $0.25
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,129 Effective Residential Rate (per kWh) $0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
30 PCE Eligible kWh vs Total kWh Sold 48.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons) 0
Non‐Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold $0
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.00
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 776,725 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
$0
Community Facility kWh Sold 365,209 Line Loss (%) $0
Other kWh Sold (Non‐PCE) 739,757 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 1,881,691 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 1,881,691
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 17 of 191
Allakaket; Alatna PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 191
Last Reported Month June
No. of Monthly Payments Made 13
Residential Customers 66
Community Facility Customers 16
Other Customers (Non‐PCE) 18
Fiscal Year PCE Payments $148,246
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 194,647 Average Annual PCE Payment per Eligible
Customer
$1,808
PCE Eligible kWh ‐ Community Facility
Customers
89,109 Average PCE Payment per Eligible kWh $0.52
Total PCE Eligible kWh 283,756 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.84
Average Monthly PCE Eligible kWh per
Residential Customer
227 Last Reported PCE Level (per kWh) $0.53
Average Monthly PCE Eligible kWh per
Community Facility Customer
428 Effective Residential Rate (per kWh) $0.31
Average Monthly PCE Eligible Community
Facility kWh per Person
36 PCE Eligible kWh vs Total kWh Sold 55.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 586,632 Fuel Used (Gallons) 49,229
Non‐Diesel kWh Generated 0 Fuel Cost $207,726
Purchased kWh 0 Average Price of Fuel $4.22
Total Purchased & Generated 586,632 Fuel Cost per kWh sold $0.40
Annual Non‐Fuel Expenses $203,961
Non‐Fuel Expense per kWh Sold $0.40
Total Expense per kWh Sold $0.80
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 202,633 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
87.7%
Community Facility kWh Sold 116,177 Line Loss (%) 8.0%
Other kWh Sold (Non‐PCE) 195,573 Fuel Efficiency (kWh per Gallon of Diesel)11.92
Total kWh Sold 514,383 PH Consumption as % of Generation 4.3%
Powerhouse (PH) Consumption kWh 25,301
Total kWh Sold & PH Consumption 539,684
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 18 of 191
Ambler PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 260
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 79
Community Facility Customers 16
Other Customers (Non‐PCE) 19
Fiscal Year PCE Payments $142,491
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 323,425 Average Annual PCE Payment per Eligible
Customer
$1,500
PCE Eligible kWh ‐ Community Facility
Customers
177,204 Average PCE Payment per Eligible kWh $0.28
Total PCE Eligible kWh 500,629 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.54
Average Monthly PCE Eligible kWh per
Residential Customer
341 Last Reported PCE Level (per kWh) $0.29
Average Monthly PCE Eligible kWh per
Community Facility Customer
923 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
57 PCE Eligible kWh vs Total kWh Sold 43.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,221,249 Fuel Used (Gallons) 91,318
Non‐Diesel kWh Generated 0 Fuel Cost $290,930
Purchased kWh 0 Average Price of Fuel $2.99
Total Purchased & Generated 1,221,249 Fuel Cost per kWh sold $0.25
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.25
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 444,148 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
94.2%
Community Facility kWh Sold 259,589 Line Loss (%) 3.7%
Other kWh Sold (Non‐PCE) 447,147 Fuel Efficiency (kWh per Gallon of Diesel)13.37
Total kWh Sold 1,150,884 PH Consumption as % of Generation 2.1%
Powerhouse (PH) Consumption kWh 25,649
Total kWh Sold & PH Consumption 1,176,533
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 19 of 191
Anaktuvuk Pass PCE
Utility: NORTH SLOPE BOROUGH
Reporting Period: 07/01/17..06/30/18
Community Population 393
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 99
Community Facility Customers 2
Other Customers (Non‐PCE) 60
Fiscal Year PCE Payments $3,104
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 236,462 Average Annual PCE Payment per Eligible
Customer
$31
PCE Eligible kWh ‐ Community Facility
Customers
42,158 Average PCE Payment per Eligible kWh $0.01
Total PCE Eligible kWh 278,620 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.15
Average Monthly PCE Eligible kWh per
Residential Customer
199 Last Reported PCE Level (per kWh) $0.00
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,757 Effective Residential Rate (per kWh) $0.15
Average Monthly PCE Eligible Community
Facility kWh per Person
9 PCE Eligible kWh vs Total kWh Sold 7.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 4,090,298 Fuel Used (Gallons) 309,615
Non‐Diesel kWh Generated 0 Fuel Cost $821,456
Purchased kWh 0 Average Price of Fuel $2.65
Total Purchased & Generated 4,090,298 Fuel Cost per kWh sold $0.23
Annual Non‐Fuel Expenses $1,170,329
Non‐Fuel Expense per kWh Sold $0.32
Total Expense per kWh Sold $0.55
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 706,928 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
89.0%
Community Facility kWh Sold 42,485 Line Loss (%) 4.2%
Other kWh Sold (Non‐PCE) 2,890,984 Fuel Efficiency (kWh per Gallon of Diesel)13.21
Total kWh Sold 3,640,397 PH Consumption as % of Generation 6.8%
Powerhouse (PH) Consumption kWh 279,743
Total kWh Sold & PH Consumption 3,920,140
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 20 of 191
Angoon PCE
Utility: INSIDE PASSAGE ELECTRIC
Reporting Period: 07/01/17..06/30/18
Community Population 408
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 193
Community Facility Customers 8
Other Customers (Non‐PCE) 33
Fiscal Year PCE Payments $255,108
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 616,778 Average Annual PCE Payment per Eligible
Customer
$1,269
PCE Eligible kWh ‐ Community Facility
Customers
221,842 Average PCE Payment per Eligible kWh $0.30
Total PCE Eligible kWh 838,620 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.56
Average Monthly PCE Eligible kWh per
Residential Customer
266 Last Reported PCE Level (per kWh) $0.31
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,311 Effective Residential Rate (per kWh) $0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
45 PCE Eligible kWh vs Total kWh Sold 53.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,792,705 Fuel Used (Gallons) 120,226
Non‐Diesel kWh Generated 0 Fuel Cost $294,298
Purchased kWh 0 Average Price of Fuel $2.45
Total Purchased & Generated 1,792,705 Fuel Cost per kWh sold $0.19
Annual Non‐Fuel Expenses $509,474
Non‐Fuel Expense per kWh Sold $0.32
Total Expense per kWh Sold $0.51
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 836,981 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
88.2%
Community Facility kWh Sold 221,842 Line Loss (%) 7.7%
Other kWh Sold (Non‐PCE) 522,413 Fuel Efficiency (kWh per Gallon of Diesel)14.91
Total kWh Sold 1,581,236 PH Consumption as % of Generation 4.1%
Powerhouse (PH) Consumption kWh 72,901
Total kWh Sold & PH Consumption 1,654,137
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 21 of 191
Aniak PCE
Utility: ANIAK LIGHT & POWER
Reporting Period: 07/01/17..06/30/18
Community Population 517
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 174
Community Facility Customers 8
Other Customers (Non‐PCE) 32
Fiscal Year PCE Payments $240,847
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 708,761 Average Annual PCE Payment per Eligible
Customer
$1,323
PCE Eligible kWh ‐ Community Facility
Customers
51,868 Average PCE Payment per Eligible kWh $0.32
Total PCE Eligible kWh 760,629 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.63
Average Monthly PCE Eligible kWh per
Residential Customer
339 Last Reported PCE Level (per kWh) $0.30
Average Monthly PCE Eligible kWh per
Community Facility Customer
540 Effective Residential Rate (per kWh) $0.33
Average Monthly PCE Eligible Community
Facility kWh per Person
8 PCE Eligible kWh vs Total kWh Sold 35.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,603,800 Fuel Used (Gallons) 200,758
Non‐Diesel kWh Generated 0 Fuel Cost $506,333
Purchased kWh 0 Average Price of Fuel $2.52
Total Purchased & Generated 2,603,800 Fuel Cost per kWh sold $0.23
Annual Non‐Fuel Expenses $716,122
Non‐Fuel Expense per kWh Sold $0.33
Total Expense per kWh Sold $0.56
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 938,576 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
83.3%
Community Facility kWh Sold 51,868 Line Loss (%) 15.4%
Other kWh Sold (Non‐PCE) 1,178,182 Fuel Efficiency (kWh per Gallon of Diesel)12.97
Total kWh Sold 2,168,626 PH Consumption as % of Generation 1.3%
Powerhouse (PH) Consumption kWh 34,982
Total kWh Sold & PH Consumption 2,203,608
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 22 of 191
Anvik PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 77
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 37
Community Facility Customers 11
Other Customers (Non‐PCE) 17
Fiscal Year PCE Payments $54,081
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 131,779 Average Annual PCE Payment per Eligible
Customer
$1,127
PCE Eligible kWh ‐ Community Facility
Customers
46,449 Average PCE Payment per Eligible kWh $0.30
Total PCE Eligible kWh 178,228 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.54
Average Monthly PCE Eligible kWh per
Residential Customer
297 Last Reported PCE Level (per kWh) $0.30
Average Monthly PCE Eligible kWh per
Community Facility Customer
352 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
50 PCE Eligible kWh vs Total kWh Sold 49.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 401,711 Fuel Used (Gallons) 32,727
Non‐Diesel kWh Generated 0 Fuel Cost $80,029
Purchased kWh 0 Average Price of Fuel $2.41
Total Purchased & Generated 401,711 Fuel Cost per kWh sold $0.22
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.22
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 148,594 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
90.6%
Community Facility kWh Sold 131,174 Line Loss (%) 5.1%
Other kWh Sold (Non‐PCE) 84,168 Fuel Efficiency (kWh per Gallon of Diesel)12.27
Total kWh Sold 363,936 PH Consumption as % of Generation 4.3%
Powerhouse (PH) Consumption kWh 17,342
Total kWh Sold & PH Consumption 381,278
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 23 of 191
Arctic Village PCE
Utility: ARCTIC VILLAGE COUNCIL
Reporting Period: 07/01/17..06/30/18
Community Population 180
Last Reported Month June
No. of Monthly Payments Made 10
Residential Customers 79
Community Facility Customers 5
Other Customers (Non‐PCE) 13
Fiscal Year PCE Payments $140,678
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 140,163 Average Annual PCE Payment per Eligible
Customer
$1,675
PCE Eligible kWh ‐ Community Facility
Customers
39,502 Average PCE Payment per Eligible kWh $0.78
Total PCE Eligible kWh 179,665 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.00
Average Monthly PCE Eligible kWh per
Residential Customer
177 Last Reported PCE Level (per kWh) $0.78
Average Monthly PCE Eligible kWh per
Community Facility Customer
790 Effective Residential Rate (per kWh) $0.22
Average Monthly PCE Eligible Community
Facility kWh per Person
22 PCE Eligible kWh vs Total kWh Sold 46.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 533,103 Fuel Used (Gallons) 46,939
Non‐Diesel kWh Generated 0 Fuel Cost $152,418
Purchased kWh 0 Average Price of Fuel $3.25
Total Purchased & Generated 533,103 Fuel Cost per kWh sold $0.40
Annual Non‐Fuel Expenses $11,771
Non‐Fuel Expense per kWh Sold $0.03
Total Expense per kWh Sold $0.43
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 166,711 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
72.3%
Community Facility kWh Sold 39,502 Line Loss (%) 27.7%
Other kWh Sold (Non‐PCE) 179,138 Fuel Efficiency (kWh per Gallon of Diesel)11.36
Total kWh Sold 385,351 PH Consumption as % of Generation 0.0%
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 385,351
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 24 of 191
Atka PCE
Utility: CITY OF ATKA
Reporting Period: 07/01/17..06/30/18
Community Population 65
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 30
Community Facility Customers 18
Other Customers (Non‐PCE) 15
Fiscal Year PCE Payments $31,034
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 98,085 Average Annual PCE Payment per Eligible
Customer
$647
PCE Eligible kWh ‐ Community Facility
Customers
32,607 Average PCE Payment per Eligible kWh $0.24
Total PCE Eligible kWh 130,692 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.63
Average Monthly PCE Eligible kWh per
Residential Customer
272 Last Reported PCE Level (per kWh) $0.24
Average Monthly PCE Eligible kWh per
Community Facility Customer
151 Effective Residential Rate (per kWh) $0.39
Average Monthly PCE Eligible Community
Facility kWh per Person
42 PCE Eligible kWh vs Total kWh Sold 36.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 57,499 Fuel Used (Gallons) 5,270
Non‐Diesel kWh Generated 389,053 Fuel Cost $23,537
Purchased kWh 0 Average Price of Fuel $4.47
Total Purchased & Generated 446,552 Fuel Cost per kWh sold $0.07
Annual Non‐Fuel Expenses $31,200
Non‐Fuel Expense per kWh Sold $0.09
Total Expense per kWh Sold $0.15
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 109,982 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
80.4%
Community Facility kWh Sold 37,734 Line Loss (%) 9.9%
Other kWh Sold (Non‐PCE) 211,191 Fuel Efficiency (kWh per Gallon of Diesel)10.91
Total kWh Sold 358,907 PH Consumption as % of Generation 9.8%
Powerhouse (PH) Consumption kWh 43,562
Total kWh Sold & PH Consumption 402,469
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 25 of 191
Atmautluak PCE
Utility: ATMAUTLUAK TRIBAL UTILITIES
Reporting Period: 07/01/17..06/30/18
Community Population 315
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 71
Community Facility Customers 6
Other Customers (Non‐PCE) 12
Fiscal Year PCE Payments $99,601
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 281,190 Average Annual PCE Payment per Eligible
Customer
$1,294
PCE Eligible kWh ‐ Community Facility
Customers
73,218 Average PCE Payment per Eligible kWh $0.28
Total PCE Eligible kWh 354,408 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.70
Average Monthly PCE Eligible kWh per
Residential Customer
330 Last Reported PCE Level (per kWh) $0.40
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,017 Effective Residential Rate (per kWh) $0.30
Average Monthly PCE Eligible Community
Facility kWh per Person
19 PCE Eligible kWh vs Total kWh Sold 57.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 661,233 Fuel Used (Gallons) 53,626
Non‐Diesel kWh Generated 0 Fuel Cost $157,872
Purchased kWh 0 Average Price of Fuel $2.94
Total Purchased & Generated 661,233 Fuel Cost per kWh sold $0.26
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.26
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 293,625 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
93.6%
Community Facility kWh Sold 75,200 Line Loss (%) 0.4%
Other kWh Sold (Non‐PCE) 249,796 Fuel Efficiency (kWh per Gallon of Diesel)12.33
Total kWh Sold 618,621 PH Consumption as % of Generation 6.1%
Powerhouse (PH) Consumption kWh 40,138
Total kWh Sold & PH Consumption 658,759
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 26 of 191
Atqasuk PCE
Utility: NORTH SLOPE BOROUGH
Reporting Period: 07/01/17..06/30/18
Community Population 248
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 61
Community Facility Customers 2
Other Customers (Non‐PCE) 54
Fiscal Year PCE Payments $5,091
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 135,318 Average Annual PCE Payment per Eligible
Customer
$81
PCE Eligible kWh ‐ Community Facility
Customers
57,857 Average PCE Payment per Eligible kWh $0.03
Total PCE Eligible kWh 193,175 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.25
Average Monthly PCE Eligible kWh per
Residential Customer
185 Last Reported PCE Level (per kWh) $0.00
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,411 Effective Residential Rate (per kWh) $0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
19 PCE Eligible kWh vs Total kWh Sold 6.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 3,405,420 Fuel Used (Gallons) 256,992
Non‐Diesel kWh Generated 0 Fuel Cost $1,125,849
Purchased kWh 0 Average Price of Fuel $4.38
Total Purchased & Generated 3,405,420 Fuel Cost per kWh sold $0.38
Annual Non‐Fuel Expenses $1,139,712
Non‐Fuel Expense per kWh Sold $0.39
Total Expense per kWh Sold $0.77
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 594,682 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
86.8%
Community Facility kWh Sold 57,857 Line Loss (%) $0
Other kWh Sold (Non‐PCE) 2,304,611 Fuel Efficiency (kWh per Gallon of Diesel)13.25
Total kWh Sold 2,957,150 PH Consumption as % of Generation 16.8%
Powerhouse (PH) Consumption kWh 571,137
Total kWh Sold & PH Consumption 3,528,287
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 27 of 191
Beaver PCE
Utility: BEAVER JOINT UTILITIES
Reporting Period: 07/01/17..06/30/18
Community Population 69
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 43
Community Facility Customers 3
Other Customers (Non‐PCE) 12
Fiscal Year PCE Payments $53,489
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 83,033 Average Annual PCE Payment per Eligible
Customer
$1,163
PCE Eligible kWh ‐ Community Facility
Customers
18,000 Average PCE Payment per Eligible kWh $0.53
Total PCE Eligible kWh 101,033 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.90
Average Monthly PCE Eligible kWh per
Residential Customer
161 Last Reported PCE Level (per kWh) $0.61
Average Monthly PCE Eligible kWh per
Community Facility Customer
500 Effective Residential Rate (per kWh) $0.29
Average Monthly PCE Eligible Community
Facility kWh per Person
22 PCE Eligible kWh vs Total kWh Sold 38.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 188,717 Fuel Used (Gallons) 25,592
Non‐Diesel kWh Generated 0 Fuel Cost $86,539
Purchased kWh 0 Average Price of Fuel $3.38
Total Purchased & Generated 188,717 Fuel Cost per kWh sold $0.33
Annual Non‐Fuel Expenses $58,136
Non‐Fuel Expense per kWh Sold $0.22
Total Expense per kWh Sold $0.54
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 84,479 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
$0
Community Facility kWh Sold 55,111 Line Loss (%) $0
Other kWh Sold (Non‐PCE) 125,931 Fuel Efficiency (kWh per Gallon of Diesel)7.37
Total kWh Sold 265,521 PH Consumption as % of Generation 1.9%
Powerhouse (PH) Consumption kWh 3,592
Total kWh Sold & PH Consumption 269,113
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 28 of 191
Bethel; Oscarville PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 6294
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 1,879
Community Facility Customers 47
Other Customers (Non‐PCE) 863
Fiscal Year PCE Payments $971,702
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 7,825,477 Average Annual PCE Payment per Eligible
Customer
$505
PCE Eligible kWh ‐ Community Facility
Customers
2,401,472 Average PCE Payment per Eligible kWh $0.10
Total PCE Eligible kWh 10,226,949 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.35
Average Monthly PCE Eligible kWh per
Residential Customer
347 Last Reported PCE Level (per kWh) $0.10
Average Monthly PCE Eligible kWh per
Community Facility Customer
4,258 Effective Residential Rate (per kWh) $0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
32 PCE Eligible kWh vs Total kWh Sold 26.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 41,360,000 Fuel Used (Gallons) 2,974,694
Non‐Diesel kWh Generated 0 Fuel Cost $9,690,144
Purchased kWh 0 Average Price of Fuel $3.04
Total Purchased & Generated 41,360,000 Fuel Cost per kWh sold $0.25
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.25
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 10,235,347 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
94.7%
Community Facility kWh Sold 8,280,174 Line Loss (%) 3.1%
Other kWh Sold (Non‐PCE) 20,642,771 Fuel Efficiency (kWh per Gallon of Diesel)13.90
Total kWh Sold 39,158,292 PH Consumption as % of Generation 2.2%
Powerhouse (PH) Consumption kWh 913,310
Total kWh Sold & PH Consumption 40,071,602
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 29 of 191
Bettles; Evansville PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 20
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 27
Community Facility Customers 5
Other Customers (Non‐PCE) 30
Fiscal Year PCE Payments $36,752
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 81,998 Average Annual PCE Payment per Eligible
Customer
$1,149
PCE Eligible kWh ‐ Community Facility
Customers
16,800 Average PCE Payment per Eligible kWh $0.37
Total PCE Eligible kWh 98,798 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.72
Average Monthly PCE Eligible kWh per
Residential Customer
253 Last Reported PCE Level (per kWh) $0.41
Average Monthly PCE Eligible kWh per
Community Facility Customer
280 Effective Residential Rate (per kWh) $0.31
Average Monthly PCE Eligible Community
Facility kWh per Person
70 PCE Eligible kWh vs Total kWh Sold 19.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 547,700 Fuel Used (Gallons) 45,702
Non‐Diesel kWh Generated 0 Fuel Cost $137,749
Purchased kWh 0 Average Price of Fuel $3.01
Total Purchased & Generated 547,700 Fuel Cost per kWh sold $0.27
Annual Non‐Fuel Expenses $347,920
Non‐Fuel Expense per kWh Sold $0.69
Total Expense per kWh Sold $0.96
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 108,410 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
92.1%
Community Facility kWh Sold 31,954 Line Loss (%) 7.7%
Other kWh Sold (Non‐PCE) 363,987 Fuel Efficiency (kWh per Gallon of Diesel)11.98
Total kWh Sold 504,351 PH Consumption as % of Generation 0.2%
Powerhouse (PH) Consumption kWh 1,145
Total kWh Sold & PH Consumption 505,496
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 30 of 191
Birch Creek PCE
Utility: BIRCH CREEK ELECTRIC COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 26
Last Reported Month June
No. of Monthly Payments Made 10
Residential Customers 13
Community Facility Customers 2
Other Customers (Non‐PCE) 7
Fiscal Year PCE Payments $17,159
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 21,960 Average Annual PCE Payment per Eligible
Customer
$1,144
PCE Eligible kWh ‐ Community Facility
Customers
0 Average PCE Payment per Eligible kWh $0.78
Total PCE Eligible kWh 21,960 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.15
Average Monthly PCE Eligible kWh per
Residential Customer
169 Last Reported PCE Level (per kWh) $0.77
Average Monthly PCE Eligible kWh per
Community Facility Customer
0 Effective Residential Rate (per kWh) $0.38
Average Monthly PCE Eligible Community
Facility kWh per Person
0 PCE Eligible kWh vs Total kWh Sold 26.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 95,324 Fuel Used (Gallons) 9,608
Non‐Diesel kWh Generated 0 Fuel Cost $33,623
Purchased kWh 0 Average Price of Fuel $3.50
Total Purchased & Generated 95,324 Fuel Cost per kWh sold $0.41
Annual Non‐Fuel Expenses $25,006
Non‐Fuel Expense per kWh Sold $0.31
Total Expense per kWh Sold $0.72
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 24,627 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
85.8%
Community Facility kWh Sold 13,940 Line Loss (%) 10.9%
Other kWh Sold (Non‐PCE) 43,184 Fuel Efficiency (kWh per Gallon of Diesel)9.92
Total kWh Sold 81,751 PH Consumption as % of Generation 3.3%
Powerhouse (PH) Consumption kWh 3,176
Total kWh Sold & PH Consumption 84,927
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 31 of 191
Brevig Mission PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 418
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 91
Community Facility Customers 10
Other Customers (Non‐PCE) 24
Fiscal Year PCE Payments $139,180
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 426,901 Average Annual PCE Payment per Eligible
Customer
$1,378
PCE Eligible kWh ‐ Community Facility
Customers
143,823 Average PCE Payment per Eligible kWh $0.24
Total PCE Eligible kWh 570,724 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.50
Average Monthly PCE Eligible kWh per
Residential Customer
391 Last Reported PCE Level (per kWh) $0.26
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,199 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
29 PCE Eligible kWh vs Total kWh Sold 51.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,187,099 Fuel Used (Gallons) 87,971
Non‐Diesel kWh Generated 0 Fuel Cost $234,680
Purchased kWh 0 Average Price of Fuel $2.67
Total Purchased & Generated 1,187,099 Fuel Cost per kWh sold $0.21
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.21
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 541,793 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
93.0%
Community Facility kWh Sold 271,638 Line Loss (%) 3.7%
Other kWh Sold (Non‐PCE) 290,687 Fuel Efficiency (kWh per Gallon of Diesel)13.49
Total kWh Sold 1,104,118 PH Consumption as % of Generation 3.3%
Powerhouse (PH) Consumption kWh 38,706
Total kWh Sold & PH Consumption 1,142,824
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 32 of 191
Buckland PCE
Utility: CITY OF BUCKLAND
Reporting Period: 07/01/17..06/30/18
Community Population 507
Last Reported Month February
No. of Monthly Payments Made 8
Residential Customers 102
Community Facility Customers 12
Other Customers (Non‐PCE) 26
Fiscal Year PCE Payments $44,462
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 320,269 Average Annual PCE Payment per Eligible
Customer
$390
PCE Eligible kWh ‐ Community Facility
Customers
13,031 Average PCE Payment per Eligible kWh $0.13
Total PCE Eligible kWh 333,300 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.47
Average Monthly PCE Eligible kWh per
Residential Customer
392 Last Reported PCE Level (per kWh) $0.13
Average Monthly PCE Eligible kWh per
Community Facility Customer
136 Effective Residential Rate (per kWh) $0.34
Average Monthly PCE Eligible Community
Facility kWh per Person
3 PCE Eligible kWh vs Total kWh Sold 38.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,080,261 Fuel Used (Gallons) 87,895
Non‐Diesel kWh Generated 28,678 Fuel Cost $287,759
Purchased kWh 0 Average Price of Fuel $3.27
Total Purchased & Generated 1,108,939 Fuel Cost per kWh sold $0.33
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.33
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 482,113 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
78.3%
Community Facility kWh Sold 34,711 Line Loss (%) 19.8%
Other kWh Sold (Non‐PCE) 350,958 Fuel Efficiency (kWh per Gallon of Diesel)12.29
Total kWh Sold 867,782 PH Consumption as % of Generation 2.0%
Powerhouse (PH) Consumption kWh 21,910
Total kWh Sold & PH Consumption 889,692
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 33 of 191
Central PCE
Utility: GOLD COUNTRY ENERGY
Reporting Period: 07/01/17..06/30/18
Community Population 86
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 136
Community Facility Customers 1
Other Customers (Non‐PCE) 14
Fiscal Year PCE Payments $86,758
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 235,205 Average Annual PCE Payment per Eligible
Customer
$633
PCE Eligible kWh ‐ Community Facility
Customers
4,805 Average PCE Payment per Eligible kWh $0.36
Total PCE Eligible kWh 240,010 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.68
Average Monthly PCE Eligible kWh per
Residential Customer
144 Last Reported PCE Level (per kWh) $0.36
Average Monthly PCE Eligible kWh per
Community Facility Customer
400 Effective Residential Rate (per kWh) $0.32
Average Monthly PCE Eligible Community
Facility kWh per Person
5 PCE Eligible kWh vs Total kWh Sold 66.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 472,671 Fuel Used (Gallons) 42,429
Non‐Diesel kWh Generated 0 Fuel Cost $96,571
Purchased kWh 0 Average Price of Fuel $2.28
Total Purchased & Generated 472,671 Fuel Cost per kWh sold $0.27
Annual Non‐Fuel Expenses $80,599
Non‐Fuel Expense per kWh Sold $0.22
Total Expense per kWh Sold $0.49
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 251,486 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
76.3%
Community Facility kWh Sold 4,805 Line Loss (%) 20.3%
Other kWh Sold (Non‐PCE) 104,401 Fuel Efficiency (kWh per Gallon of Diesel)11.14
Total kWh Sold 360,692 PH Consumption as % of Generation 3.4%
Powerhouse (PH) Consumption kWh 15,981
Total kWh Sold & PH Consumption 376,673
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 34 of 191
Chalkyitsik PCE
Utility: CHALKYITSIK VILLAGE COUNCIL
Reporting Period: 07/01/17..06/30/18
Community Population 79
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 43
Community Facility Customers 10
Other Customers (Non‐PCE) 10
Fiscal Year PCE Payments $49,727
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 54,278 Average Annual PCE Payment per Eligible
Customer
$938
PCE Eligible kWh ‐ Community Facility
Customers
60,833 Average PCE Payment per Eligible kWh $0.43
Total PCE Eligible kWh 115,111 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.95
Average Monthly PCE Eligible kWh per
Residential Customer
105 Last Reported PCE Level (per kWh) $0.51
Average Monthly PCE Eligible kWh per
Community Facility Customer
507 Effective Residential Rate (per kWh) $0.44
Average Monthly PCE Eligible Community
Facility kWh per Person
64 PCE Eligible kWh vs Total kWh Sold 52.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 338,590 Fuel Used (Gallons) 31,387
Non‐Diesel kWh Generated 0 Fuel Cost $125,576
Purchased kWh 0 Average Price of Fuel $4.00
Total Purchased & Generated 338,590 Fuel Cost per kWh sold $0.57
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.57
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 62,589 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
65.0%
Community Facility kWh Sold 92,814 Line Loss (%) 23.4%
Other kWh Sold (Non‐PCE) 64,827 Fuel Efficiency (kWh per Gallon of Diesel)10.79
Total kWh Sold 220,230 PH Consumption as % of Generation 11.5%
Powerhouse (PH) Consumption kWh 39,081
Total kWh Sold & PH Consumption 259,311
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 35 of 191
Chefornak PCE
Utility: NATERKAQ LIGHT PLANT
Reporting Period: 07/01/17..06/30/18
Community Population 442
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 93
Community Facility Customers 18
Other Customers (Non‐PCE) 30
Fiscal Year PCE Payments $119,604
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 431,801 Average Annual PCE Payment per Eligible
Customer
$1,078
PCE Eligible kWh ‐ Community Facility
Customers
67,339 Average PCE Payment per Eligible kWh $0.24
Total PCE Eligible kWh 499,140 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.49
Average Monthly PCE Eligible kWh per
Residential Customer
387 Last Reported PCE Level (per kWh) $0.31
Average Monthly PCE Eligible kWh per
Community Facility Customer
312 Effective Residential Rate (per kWh) $0.18
Average Monthly PCE Eligible Community
Facility kWh per Person
13 PCE Eligible kWh vs Total kWh Sold 38.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,488,308 Fuel Used (Gallons) 113,917
Non‐Diesel kWh Generated 0 Fuel Cost $341,301
Purchased kWh 0 Average Price of Fuel $3.00
Total Purchased & Generated 1,488,308 Fuel Cost per kWh sold $0.26
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.26
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 510,110 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
88.1%
Community Facility kWh Sold 104,443 Line Loss (%) 9.3%
Other kWh Sold (Non‐PCE) 696,681 Fuel Efficiency (kWh per Gallon of Diesel)13.06
Total kWh Sold 1,311,234 PH Consumption as % of Generation 2.6%
Powerhouse (PH) Consumption kWh 38,152
Total kWh Sold & PH Consumption 1,349,386
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 36 of 191
Chenega Bay PCE
Utility: NATIVE VILLAGE OF CHENEGA
Reporting Period: 07/01/17..06/30/18
Community Population 72
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 25
Community Facility Customers 9
Other Customers (Non‐PCE) 20
Fiscal Year PCE Payments $38,865
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 73,856 Average Annual PCE Payment per Eligible
Customer
$1,143
PCE Eligible kWh ‐ Community Facility
Customers
34,956 Average PCE Payment per Eligible kWh $0.36
Total PCE Eligible kWh 108,812 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.67
Average Monthly PCE Eligible kWh per
Residential Customer
246 Last Reported PCE Level (per kWh) $0.37
Average Monthly PCE Eligible kWh per
Community Facility Customer
324 Effective Residential Rate (per kWh) $0.30
Average Monthly PCE Eligible Community
Facility kWh per Person
40 PCE Eligible kWh vs Total kWh Sold 48.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 262,988 Fuel Used (Gallons) 24,781
Non‐Diesel kWh Generated 0 Fuel Cost $104,120
Purchased kWh 0 Average Price of Fuel $4.20
Total Purchased & Generated 262,988 Fuel Cost per kWh sold $0.46
Annual Non‐Fuel Expenses $15,784
Non‐Fuel Expense per kWh Sold $0.07
Total Expense per kWh Sold $0.53
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 85,660 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
85.5%
Community Facility kWh Sold 47,680 Line Loss (%) 8.2%
Other kWh Sold (Non‐PCE) 91,429 Fuel Efficiency (kWh per Gallon of Diesel)10.61
Total kWh Sold 224,769 PH Consumption as % of Generation 6.4%
Powerhouse (PH) Consumption kWh 16,742
Total kWh Sold & PH Consumption 241,511
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 37 of 191
Chevak PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 1030
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 205
Community Facility Customers 10
Other Customers (Non‐PCE) 38
Fiscal Year PCE Payments $288,115
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 843,847 Average Annual PCE Payment per Eligible
Customer
$1,340
PCE Eligible kWh ‐ Community Facility
Customers
240,446 Average PCE Payment per Eligible kWh $0.27
Total PCE Eligible kWh 1,084,293 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.53
Average Monthly PCE Eligible kWh per
Residential Customer
343 Last Reported PCE Level (per kWh) $0.25
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,004 Effective Residential Rate (per kWh) $0.28
Average Monthly PCE Eligible Community
Facility kWh per Person
19 PCE Eligible kWh vs Total kWh Sold 46.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,768,147 Fuel Used (Gallons) 141,847
Non‐Diesel kWh Generated 768,927 Fuel Cost $372,375
Purchased kWh 0 Average Price of Fuel $2.63
Total Purchased & Generated 2,537,074 Fuel Cost per kWh sold $0.16
Annual Non‐Fuel Expenses $514,297
Non‐Fuel Expense per kWh Sold $0.22
Total Expense per kWh Sold $0.38
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 978,989 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
92.9%
Community Facility kWh Sold 467,650 Line Loss (%) 3.8%
Other kWh Sold (Non‐PCE) 910,343 Fuel Efficiency (kWh per Gallon of Diesel)12.47
Total kWh Sold 2,356,982 PH Consumption as % of Generation 3.3%
Powerhouse (PH) Consumption kWh 84,732
Total kWh Sold & PH Consumption 2,441,714
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 38 of 191
Chignik Lagoon PCE
Utility: CHIGNIK LAGOON POWER UTILITY
Reporting Period: 07/01/17..06/30/18
Community Population 85
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 78
Community Facility Customers 6
Other Customers (Non‐PCE) 12
Fiscal Year PCE Payments $51,088
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 146,074 Average Annual PCE Payment per Eligible
Customer
$608
PCE Eligible kWh ‐ Community Facility
Customers
58,134 Average PCE Payment per Eligible kWh $0.25
Total PCE Eligible kWh 204,208 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.63
Average Monthly PCE Eligible kWh per
Residential Customer
156 Last Reported PCE Level (per kWh) $0.25
Average Monthly PCE Eligible kWh per
Community Facility Customer
807 Effective Residential Rate (per kWh) $0.38
Average Monthly PCE Eligible Community
Facility kWh per Person
57 PCE Eligible kWh vs Total kWh Sold 38.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 256,058 Fuel Used (Gallons) 22,734
Non‐Diesel kWh Generated 360,720 Fuel Cost $67,037
Purchased kWh 0 Average Price of Fuel $2.95
Total Purchased & Generated 616,778 Fuel Cost per kWh sold $0.13
Annual Non‐Fuel Expenses $183,008
Non‐Fuel Expense per kWh Sold $0.35
Total Expense per kWh Sold $0.47
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 260,534 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
85.4%
Community Facility kWh Sold 59,303 Line Loss (%) 11.9%
Other kWh Sold (Non‐PCE) 206,645 Fuel Efficiency (kWh per Gallon of Diesel)11.26
Total kWh Sold 526,482 PH Consumption as % of Generation 2.7%
Powerhouse (PH) Consumption kWh 16,647
Total kWh Sold & PH Consumption 543,129
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 39 of 191
Chignik Lake PCE
Utility: CHIGNIK LAKE ELECTRIC UTILITY
Reporting Period: 07/01/17..06/30/18
Community Population 64
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 42
Community Facility Customers 8
Other Customers (Non‐PCE) 6
Fiscal Year PCE Payments $60,655
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 110,341 Average Annual PCE Payment per Eligible
Customer
$1,213
PCE Eligible kWh ‐ Community Facility
Customers
36,432 Average PCE Payment per Eligible kWh $0.41
Total PCE Eligible kWh 146,773 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.85
Average Monthly PCE Eligible kWh per
Residential Customer
219 Last Reported PCE Level (per kWh) $0.40
Average Monthly PCE Eligible kWh per
Community Facility Customer
380 Effective Residential Rate (per kWh) $0.45
Average Monthly PCE Eligible Community
Facility kWh per Person
47 PCE Eligible kWh vs Total kWh Sold 48.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 333,101 Fuel Used (Gallons) 31,945
Non‐Diesel kWh Generated 0 Fuel Cost $120,921
Purchased kWh 0 Average Price of Fuel $3.79
Total Purchased & Generated 333,101 Fuel Cost per kWh sold $0.40
Annual Non‐Fuel Expenses $27,090
Non‐Fuel Expense per kWh Sold $0.09
Total Expense per kWh Sold $0.49
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 134,229 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
90.3%
Community Facility kWh Sold 38,626 Line Loss (%) 7.2%
Other kWh Sold (Non‐PCE) 127,842 Fuel Efficiency (kWh per Gallon of Diesel)10.43
Total kWh Sold 300,697 PH Consumption as % of Generation 2.6%
Powerhouse (PH) Consumption kWh 8,575
Total kWh Sold & PH Consumption 309,272
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 40 of 191
Chignik PCE
Utility: CITY OF CHIGNIK
Reporting Period: 07/01/17..06/30/18
Community Population 96
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 60
Community Facility Customers 10
Other Customers (Non‐PCE) 32
Fiscal Year PCE Payments $55,252
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 150,918 Average Annual PCE Payment per Eligible
Customer
$789
PCE Eligible kWh ‐ Community Facility
Customers
80,531 Average PCE Payment per Eligible kWh $0.24
Total PCE Eligible kWh 231,449 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.42
Average Monthly PCE Eligible kWh per
Residential Customer
210 Last Reported PCE Level (per kWh) $0.23
Average Monthly PCE Eligible kWh per
Community Facility Customer
671 Effective Residential Rate (per kWh) $0.19
Average Monthly PCE Eligible Community
Facility kWh per Person
70 PCE Eligible kWh vs Total kWh Sold 35.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 769,046 Fuel Used (Gallons) 63,229
Non‐Diesel kWh Generated 0 Fuel Cost $148,072
Purchased kWh 0 Average Price of Fuel $2.34
Total Purchased & Generated 769,046 Fuel Cost per kWh sold $0.23
Annual Non‐Fuel Expenses $141,167
Non‐Fuel Expense per kWh Sold $0.22
Total Expense per kWh Sold $0.44
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 174,000 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
84.9%
Community Facility kWh Sold 89,408 Line Loss (%) 11.9%
Other kWh Sold (Non‐PCE) 389,212 Fuel Efficiency (kWh per Gallon of Diesel)12.16
Total kWh Sold 652,620 PH Consumption as % of Generation 3.3%
Powerhouse (PH) Consumption kWh 25,067
Total kWh Sold & PH Consumption 677,687
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 41 of 191
Chilkat Valley PCE
Utility: INSIDE PASSAGE ELECTRIC
Reporting Period: 07/01/17..06/30/18
Community Population 666
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 210
Community Facility Customers 1
Other Customers (Non‐PCE) 40
Fiscal Year PCE Payments $172,074
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 564,530 Average Annual PCE Payment per Eligible
Customer
$816
PCE Eligible kWh ‐ Community Facility
Customers
1,436 Average PCE Payment per Eligible kWh $0.30
Total PCE Eligible kWh 565,966 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.56
Average Monthly PCE Eligible kWh per
Residential Customer
224 Last Reported PCE Level (per kWh) $0.31
Average Monthly PCE Eligible kWh per
Community Facility Customer
120 Effective Residential Rate (per kWh) $0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
0 PCE Eligible kWh vs Total kWh Sold 52.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons) 0
Non‐Diesel kWh Generated 1,051,920 Fuel Cost $0
Purchased kWh 774,900 Average Price of Fuel $0.00
Total Purchased & Generated 1,826,820 Fuel Cost per kWh sold $0
Annual Non‐Fuel Expenses $545,231
Non‐Fuel Expense per kWh Sold $0.51
Total Expense per kWh Sold $0.51
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 697,848 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
58.6%
Community Facility kWh Sold 1,436 Line Loss (%) 38.1%
Other kWh Sold (Non‐PCE) 371,517 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 1,070,801 PH Consumption as % of Generation 3.3%
Powerhouse (PH) Consumption kWh 60,198
Total kWh Sold & PH Consumption 1,130,999
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 42 of 191
Chistochina PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 88
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 45
Community Facility Customers 1
Other Customers (Non‐PCE) 19
Fiscal Year PCE Payments $43,440
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 131,219 Average Annual PCE Payment per Eligible
Customer
$944
PCE Eligible kWh ‐ Community Facility
Customers
12,580 Average PCE Payment per Eligible kWh $0.30
Total PCE Eligible kWh 143,799 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.66
Average Monthly PCE Eligible kWh per
Residential Customer
243 Last Reported PCE Level (per kWh) $0.36
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,048 Effective Residential Rate (per kWh) $0.30
Average Monthly PCE Eligible Community
Facility kWh per Person
12 PCE Eligible kWh vs Total kWh Sold 43.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons) 0
Non‐Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold $0
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.00
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 146,874 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
$0
Community Facility kWh Sold 12,580 Line Loss (%) $0
Other kWh Sold (Non‐PCE) 170,052 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 329,506 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 2,393
Total kWh Sold & PH Consumption 331,899
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Utility is intertied to another facility and does not generate power for sales to its customers.
Page 43 of 191
Chitina PCE
Utility: CHITINA ELECTRIC INC.
Reporting Period: 07/01/17..06/30/18
Community Population 104
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 44
Community Facility Customers 2
Other Customers (Non‐PCE) 34
Fiscal Year PCE Payments $36,600
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 91,556 Average Annual PCE Payment per Eligible
Customer
$796
PCE Eligible kWh ‐ Community Facility
Customers
13,916 Average PCE Payment per Eligible kWh $0.35
Total PCE Eligible kWh 105,472 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.70
Average Monthly PCE Eligible kWh per
Residential Customer
173 Last Reported PCE Level (per kWh) $0.37
Average Monthly PCE Eligible kWh per
Community Facility Customer
580 Effective Residential Rate (per kWh) $0.33
Average Monthly PCE Eligible Community
Facility kWh per Person
11 PCE Eligible kWh vs Total kWh Sold 28.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 442,908 Fuel Used (Gallons) 37,716
Non‐Diesel kWh Generated 0 Fuel Cost $111,317
Purchased kWh 0 Average Price of Fuel $2.95
Total Purchased & Generated 442,908 Fuel Cost per kWh sold $0.30
Annual Non‐Fuel Expenses $139,667
Non‐Fuel Expense per kWh Sold $0.37
Total Expense per kWh Sold $0.67
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 117,019 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
84.8%
Community Facility kWh Sold 13,916 Line Loss (%) 5.9%
Other kWh Sold (Non‐PCE) 244,600 Fuel Efficiency (kWh per Gallon of Diesel)11.74
Total kWh Sold 375,535 PH Consumption as % of Generation 9.3%
Powerhouse (PH) Consumption kWh 41,341
Total kWh Sold & PH Consumption 416,876
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 44 of 191
Chuathbaluk PCE
Utility: MIDDLE KUSKOKWIM ELECTRIC COOPERATIVE INC
Reporting Period: 07/01/17..06/30/18
Community Population 118
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 32
Community Facility Customers 10
Other Customers (Non‐PCE) 7
Fiscal Year PCE Payments $86,624
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 79,771 Average Annual PCE Payment per Eligible
Customer
$2,062
PCE Eligible kWh ‐ Community Facility
Customers
42,223 Average PCE Payment per Eligible kWh $0.71
Total PCE Eligible kWh 121,994 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.18
Average Monthly PCE Eligible kWh per
Residential Customer
208 Last Reported PCE Level (per kWh) $0.74
Average Monthly PCE Eligible kWh per
Community Facility Customer
352 Effective Residential Rate (per kWh) $0.44
Average Monthly PCE Eligible Community
Facility kWh per Person
30 PCE Eligible kWh vs Total kWh Sold 58.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 240,771 Fuel Used (Gallons) 21,184
Non‐Diesel kWh Generated 0 Fuel Cost $60,609
Purchased kWh 0 Average Price of Fuel $2.86
Total Purchased & Generated 240,771 Fuel Cost per kWh sold $0.29
Annual Non‐Fuel Expenses $176,382
Non‐Fuel Expense per kWh Sold $0.84
Total Expense per kWh Sold $1.13
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 81,037 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
87.1%
Community Facility kWh Sold 44,362 Line Loss (%) 8.8%
Other kWh Sold (Non‐PCE) 84,326 Fuel Efficiency (kWh per Gallon of Diesel)11.37
Total kWh Sold 209,725 PH Consumption as % of Generation 4.1%
Powerhouse (PH) Consumption kWh 9,952
Total kWh Sold & PH Consumption 219,677
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 45 of 191
Circle PCE
Utility: CIRCLE ELECTRIC LLC
Reporting Period: 07/01/17..06/30/18
Community Population 108
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 38
Community Facility Customers 7
Other Customers (Non‐PCE) 8
Fiscal Year PCE Payments $79,710
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 95,746 Average Annual PCE Payment per Eligible
Customer
$1,771
PCE Eligible kWh ‐ Community Facility
Customers
69,485 Average PCE Payment per Eligible kWh $0.48
Total PCE Eligible kWh 165,231 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.76
Average Monthly PCE Eligible kWh per
Residential Customer
210 Last Reported PCE Level (per kWh) $0.53
Average Monthly PCE Eligible kWh per
Community Facility Customer
827 Effective Residential Rate (per kWh) $0.23
Average Monthly PCE Eligible Community
Facility kWh per Person
54 PCE Eligible kWh vs Total kWh Sold 44.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 401,960 Fuel Used (Gallons) 36,687
Non‐Diesel kWh Generated 0 Fuel Cost $94,035
Purchased kWh 0 Average Price of Fuel $2.56
Total Purchased & Generated 401,960 Fuel Cost per kWh sold $0.26
Annual Non‐Fuel Expenses $139,550
Non‐Fuel Expense per kWh Sold $0.38
Total Expense per kWh Sold $0.64
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 125,118 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
91.5%
Community Facility kWh Sold 81,266 Line Loss (%) 7.9%
Other kWh Sold (Non‐PCE) 161,414 Fuel Efficiency (kWh per Gallon of Diesel)10.96
Total kWh Sold 367,798 PH Consumption as % of Generation 0.6%
Powerhouse (PH) Consumption kWh 2,410
Total kWh Sold & PH Consumption 370,208
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 46 of 191
Clarks Point PCE
Utility: CLARKS POINT VILLAGE COUNCIL
Reporting Period: 07/01/17..06/30/18
Community Population 54
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 42
Community Facility Customers 7
Other Customers (Non‐PCE) 14
Fiscal Year PCE Payments $80,701
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 99,759 Average Annual PCE Payment per Eligible
Customer
$1,647
PCE Eligible kWh ‐ Community Facility
Customers
27,875 Average PCE Payment per Eligible kWh $0.63
Total PCE Eligible kWh 127,634 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.10
Average Monthly PCE Eligible kWh per
Residential Customer
198 Last Reported PCE Level (per kWh) $0.65
Average Monthly PCE Eligible kWh per
Community Facility Customer
332 Effective Residential Rate (per kWh) $0.45
Average Monthly PCE Eligible Community
Facility kWh per Person
43 PCE Eligible kWh vs Total kWh Sold 52.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 285,900 Fuel Used (Gallons) 30,995
Non‐Diesel kWh Generated 0 Fuel Cost $99,801
Purchased kWh 0 Average Price of Fuel $3.22
Total Purchased & Generated 285,900 Fuel Cost per kWh sold $0.41
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.41
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 124,359 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
85.5%
Community Facility kWh Sold 31,894 Line Loss (%) 7.6%
Other kWh Sold (Non‐PCE) 88,161 Fuel Efficiency (kWh per Gallon of Diesel)9.22
Total kWh Sold 244,414 PH Consumption as % of Generation 6.9%
Powerhouse (PH) Consumption kWh 19,816
Total kWh Sold & PH Consumption 264,230
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 47 of 191
Coffman Cove PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 204
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 179
Community Facility Customers 14
Other Customers (Non‐PCE) 46
Fiscal Year PCE Payments $16,325
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 491,992 Average Annual PCE Payment per Eligible
Customer
$85
PCE Eligible kWh ‐ Community Facility
Customers
88,050 Average PCE Payment per Eligible kWh $0.03
Total PCE Eligible kWh 580,042 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.29
Average Monthly PCE Eligible kWh per
Residential Customer
229 Last Reported PCE Level (per kWh) $0.04
Average Monthly PCE Eligible kWh per
Community Facility Customer
524 Effective Residential Rate (per kWh) $0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
36 PCE Eligible kWh vs Total kWh Sold 54.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons) 0
Non‐Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold $0
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.00
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 713,523 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
$0
Community Facility kWh Sold 88,050 Line Loss (%) $0
Other kWh Sold (Non‐PCE) 264,118 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 1,065,691 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 45,624
Total kWh Sold & PH Consumption 1,111,315
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 48 of 191
Cold Bay PCE
Utility: G & K INC.
Reporting Period: 07/01/17..06/30/18
Community Population 59
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 38
Community Facility Customers 4
Other Customers (Non‐PCE) 77
Fiscal Year PCE Payments $53,854
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 68,983 Average Annual PCE Payment per Eligible
Customer
$1,282
PCE Eligible kWh ‐ Community Facility
Customers
49,380 Average PCE Payment per Eligible kWh $0.45
Total PCE Eligible kWh 118,363 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.67
Average Monthly PCE Eligible kWh per
Residential Customer
151 Last Reported PCE Level (per kWh) $0.44
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,029 Effective Residential Rate (per kWh) $0.22
Average Monthly PCE Eligible Community
Facility kWh per Person
70 PCE Eligible kWh vs Total kWh Sold 6.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,429,402 Fuel Used (Gallons) 184,622
Non‐Diesel kWh Generated 0 Fuel Cost $838,184
Purchased kWh 0 Average Price of Fuel $4.54
Total Purchased & Generated 2,429,402 Fuel Cost per kWh sold $0.45
Annual Non‐Fuel Expenses $105,180
Non‐Fuel Expense per kWh Sold $0.06
Total Expense per kWh Sold $0.51
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 154,225 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
75.8%
Community Facility kWh Sold 61,971 Line Loss (%) 16.7%
Other kWh Sold (Non‐PCE) 1,626,091 Fuel Efficiency (kWh per Gallon of Diesel)13.16
Total kWh Sold 1,842,287 PH Consumption as % of Generation 7.4%
Powerhouse (PH) Consumption kWh 180,876
Total kWh Sold & PH Consumption 2,023,163
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 49 of 191
Cordova PCE
Utility: CORDOVA ELECTRIC
Reporting Period: 07/01/17..06/30/18
Community Population 2522
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 969
Community Facility Customers 59
Other Customers (Non‐PCE) 606
Fiscal Year PCE Payments $487,319
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 3,332,589 Average Annual PCE Payment per Eligible
Customer
$474
PCE Eligible kWh ‐ Community Facility
Customers
2,095,784 Average PCE Payment per Eligible kWh $0.09
Total PCE Eligible kWh 5,428,373 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.35
Average Monthly PCE Eligible kWh per
Residential Customer
287 Last Reported PCE Level (per kWh) $0.08
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,960 Effective Residential Rate (per kWh) $0.27
Average Monthly PCE Eligible Community
Facility kWh per Person
69 PCE Eligible kWh vs Total kWh Sold 20.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 8,434,147 Fuel Used (Gallons) 618,447
Non‐Diesel kWh Generated 19,380,402 Fuel Cost $1,537,429
Purchased kWh 0 Average Price of Fuel $2.49
Total Purchased & Generated 27,814,549 Fuel Cost per kWh sold $0.06
Annual Non‐Fuel Expenses $5,263,043
Non‐Fuel Expense per kWh Sold $0.20
Total Expense per kWh Sold $0.26
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 4,794,311 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
94.8%
Community Facility kWh Sold 2,500,376 Line Loss (%) 4.7%
Other kWh Sold (Non‐PCE) 19,077,636 Fuel Efficiency (kWh per Gallon of Diesel)13.64
Total kWh Sold 26,372,323 PH Consumption as % of Generation 0.5%
Powerhouse (PH) Consumption kWh 138,011
Total kWh Sold & PH Consumption 26,510,334
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 50 of 191
Craig PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 1102
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 694
Community Facility Customers 44
Other Customers (Non‐PCE) 310
Fiscal Year PCE Payments $94,967
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 2,433,601 Average Annual PCE Payment per Eligible
Customer
$129
PCE Eligible kWh ‐ Community Facility
Customers
925,482 Average PCE Payment per Eligible kWh $0.03
Total PCE Eligible kWh 3,359,083 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.29
Average Monthly PCE Eligible kWh per
Residential Customer
292 Last Reported PCE Level (per kWh) $0.04
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,753 Effective Residential Rate (per kWh) $0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
70 PCE Eligible kWh vs Total kWh Sold 35.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 4,008,958 Fuel Used (Gallons) 288,612
Non‐Diesel kWh Generated 0 Fuel Cost $695,291
Purchased kWh 24,481,200 Average Price of Fuel $2.41
Total Purchased & Generated 28,490,158 Fuel Cost per kWh sold $0.07
Annual Non‐Fuel Expenses $3,677,486
Non‐Fuel Expense per kWh Sold $0.39
Total Expense per kWh Sold $0.47
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 3,555,320 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
33.0%
Community Facility kWh Sold 1,254,978 Line Loss (%) 66.3%
Other kWh Sold (Non‐PCE) 4,592,579 Fuel Efficiency (kWh per Gallon of Diesel)13.89
Total kWh Sold 9,402,877 PH Consumption as % of Generation 0.6%
Powerhouse (PH) Consumption kWh 184,471
Total kWh Sold & PH Consumption 9,587,348
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 51 of 191
Crooked Creek PCE
Utility: MIDDLE KUSKOKWIM ELECTRIC COOPERATIVE INC
Reporting Period: 07/01/17..06/30/18
Community Population 92
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 30
Community Facility Customers 4
Other Customers (Non‐PCE) 12
Fiscal Year PCE Payments $75,510
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 79,454 Average Annual PCE Payment per Eligible
Customer
$2,221
PCE Eligible kWh ‐ Community Facility
Customers
27,236 Average PCE Payment per Eligible kWh $0.71
Total PCE Eligible kWh 106,690 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.18
Average Monthly PCE Eligible kWh per
Residential Customer
221 Last Reported PCE Level (per kWh) $0.74
Average Monthly PCE Eligible kWh per
Community Facility Customer
567 Effective Residential Rate (per kWh) $0.44
Average Monthly PCE Eligible Community
Facility kWh per Person
25 PCE Eligible kWh vs Total kWh Sold 48.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 245,714 Fuel Used (Gallons) 21,552
Non‐Diesel kWh Generated 0 Fuel Cost $61,631
Purchased kWh 0 Average Price of Fuel $2.86
Total Purchased & Generated 245,714 Fuel Cost per kWh sold $0.28
Annual Non‐Fuel Expenses $186,807
Non‐Fuel Expense per kWh Sold $0.85
Total Expense per kWh Sold $1.13
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 86,239 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
89.8%
Community Facility kWh Sold 27,236 Line Loss (%) 4.7%
Other kWh Sold (Non‐PCE) 107,075 Fuel Efficiency (kWh per Gallon of Diesel)11.40
Total kWh Sold 220,550 PH Consumption as % of Generation 5.5%
Powerhouse (PH) Consumption kWh 13,493
Total kWh Sold & PH Consumption 234,043
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 52 of 191
Deering PCE
Utility: IPNATCHIAQ ELECTRIC COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 143
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 48
Community Facility Customers 5
Other Customers (Non‐PCE) 15
Fiscal Year PCE Payments $72,872
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 191,679 Average Annual PCE Payment per Eligible
Customer
$1,375
PCE Eligible kWh ‐ Community Facility
Customers
89,927 Average PCE Payment per Eligible kWh $0.26
Total PCE Eligible kWh 281,606 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.65
Average Monthly PCE Eligible kWh per
Residential Customer
333 Last Reported PCE Level (per kWh) $0.26
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,499 Effective Residential Rate (per kWh) $0.39
Average Monthly PCE Eligible Community
Facility kWh per Person
52 PCE Eligible kWh vs Total kWh Sold 44.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 562,846 Fuel Used (Gallons) 45,719
Non‐Diesel kWh Generated 54,986 Fuel Cost $119,960
Purchased kWh 0 Average Price of Fuel $2.62
Total Purchased & Generated 617,832 Fuel Cost per kWh sold $0.19
Annual Non‐Fuel Expenses $300,978
Non‐Fuel Expense per kWh Sold $0.48
Total Expense per kWh Sold $0.67
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 226,197 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
$0
Community Facility kWh Sold 99,497 Line Loss (%) $0
Other kWh Sold (Non‐PCE) 303,136 Fuel Efficiency (kWh per Gallon of Diesel)12.31
Total kWh Sold 628,830 PH Consumption as % of Generation 4.6%
Powerhouse (PH) Consumption kWh 28,366
Total kWh Sold & PH Consumption 657,196
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 53 of 191
Dillingham; Aleknagik PCE
Utility: NUSHAGAK ELECTRIC AND
Reporting Period: 07/01/17..06/30/18
Community Population 2533
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 1,013
Community Facility Customers 54
Other Customers (Non‐PCE) 463
Fiscal Year PCE Payments $745,994
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 3,880,648 Average Annual PCE Payment per Eligible
Customer
$699
PCE Eligible kWh ‐ Community Facility
Customers
753,758 Average PCE Payment per Eligible kWh $0.16
Total PCE Eligible kWh 4,634,406 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.42
Average Monthly PCE Eligible kWh per
Residential Customer
319 Last Reported PCE Level (per kWh) $0.16
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,163 Effective Residential Rate (per kWh) $0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
25 PCE Eligible kWh vs Total kWh Sold 26.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 18,877,300 Fuel Used (Gallons) 1,268,423
Non‐Diesel kWh Generated 0 Fuel Cost $2,624,397
Purchased kWh 0 Average Price of Fuel $2.07
Total Purchased & Generated 18,877,300 Fuel Cost per kWh sold $0.15
Annual Non‐Fuel Expenses $3,971,212
Non‐Fuel Expense per kWh Sold $0.23
Total Expense per kWh Sold $0.38
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 5,190,898 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
92.5%
Community Facility kWh Sold 1,079,204 Line Loss (%) 5.5%
Other kWh Sold (Non‐PCE) 11,184,169 Fuel Efficiency (kWh per Gallon of Diesel)14.88
Total kWh Sold 17,454,271 PH Consumption as % of Generation 2.0%
Powerhouse (PH) Consumption kWh 383,400
Total kWh Sold & PH Consumption 17,837,671
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 54 of 191
Diomede PCE
Utility: DIOMEDE JOINT UTLITIES
Reporting Period: 07/01/17..06/30/18
Community Population 88
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 39
Community Facility Customers 4
Other Customers (Non‐PCE) 14
Fiscal Year PCE Payments $38,129
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 145,957 Average Annual PCE Payment per Eligible
Customer
$887
PCE Eligible kWh ‐ Community Facility
Customers
27,627 Average PCE Payment per Eligible kWh $0.22
Total PCE Eligible kWh 173,584 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.65
Average Monthly PCE Eligible kWh per
Residential Customer
312 Last Reported PCE Level (per kWh) $0.22
Average Monthly PCE Eligible kWh per
Community Facility Customer
576 Effective Residential Rate (per kWh) $0.43
Average Monthly PCE Eligible Community
Facility kWh per Person
26 PCE Eligible kWh vs Total kWh Sold 38.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 468,515 Fuel Used (Gallons) 48,293
Non‐Diesel kWh Generated 0 Fuel Cost $110,792
Purchased kWh 0 Average Price of Fuel $2.29
Total Purchased & Generated 468,515 Fuel Cost per kWh sold $0.25
Annual Non‐Fuel Expenses $183,705
Non‐Fuel Expense per kWh Sold $0.41
Total Expense per kWh Sold $0.65
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 205,147 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
96.2%
Community Facility kWh Sold 16,886 Line Loss (%) $0
Other kWh Sold (Non‐PCE) 228,891 Fuel Efficiency (kWh per Gallon of Diesel)9.70
Total kWh Sold 450,924 PH Consumption as % of Generation 8.2%
Powerhouse (PH) Consumption kWh 38,237
Total kWh Sold & PH Consumption 489,161
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 55 of 191
Dot Lake; Dot Lake Village PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 79
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 24
Community Facility Customers 2
Other Customers (Non‐PCE) 17
Fiscal Year PCE Payments $14,717
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 73,028 Average Annual PCE Payment per Eligible
Customer
$566
PCE Eligible kWh ‐ Community Facility
Customers
0 Average PCE Payment per Eligible kWh $0.20
Total PCE Eligible kWh 73,028 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.46
Average Monthly PCE Eligible kWh per
Residential Customer
254 Last Reported PCE Level (per kWh) $0.29
Average Monthly PCE Eligible kWh per
Community Facility Customer
0 Effective Residential Rate (per kWh) $0.18
Average Monthly PCE Eligible Community
Facility kWh per Person
0 PCE Eligible kWh vs Total kWh Sold 19.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons) 0
Non‐Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold $0
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.00
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 83,644 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
$0
Community Facility kWh Sold 13,636 Line Loss (%) $0
Other kWh Sold (Non‐PCE) 273,425 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 370,705 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 370,705
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Utility is intertied to another facility and does not generate power for sales to its customers.
Page 56 of 191
Eagle; Eagle Village PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 145
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 137
Community Facility Customers 13
Other Customers (Non‐PCE) 32
Fiscal Year PCE Payments $104,495
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 275,730 Average Annual PCE Payment per Eligible
Customer
$697
PCE Eligible kWh ‐ Community Facility
Customers
60,286 Average PCE Payment per Eligible kWh $0.31
Total PCE Eligible kWh 336,016 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.63
Average Monthly PCE Eligible kWh per
Residential Customer
168 Last Reported PCE Level (per kWh) $0.33
Average Monthly PCE Eligible kWh per
Community Facility Customer
386 Effective Residential Rate (per kWh) $0.30
Average Monthly PCE Eligible Community
Facility kWh per Person
35 PCE Eligible kWh vs Total kWh Sold 48.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 793,380 Fuel Used (Gallons) 59,733
Non‐Diesel kWh Generated 23,264 Fuel Cost $142,043
Purchased kWh 0 Average Price of Fuel $2.38
Total Purchased & Generated 816,644 Fuel Cost per kWh sold $0.21
Annual Non‐Fuel Expenses $458,915
Non‐Fuel Expense per kWh Sold $0.67
Total Expense per kWh Sold $0.87
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 311,751 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
84.3%
Community Facility kWh Sold 60,286 Line Loss (%) 13.8%
Other kWh Sold (Non‐PCE) 316,603 Fuel Efficiency (kWh per Gallon of Diesel)13.28
Total kWh Sold 688,640 PH Consumption as % of Generation 1.9%
Powerhouse (PH) Consumption kWh 15,712
Total kWh Sold & PH Consumption 704,352
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 57 of 191
Eek PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 341
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 110
Community Facility Customers 10
Other Customers (Non‐PCE) 22
Fiscal Year PCE Payments $126,133
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 378,538 Average Annual PCE Payment per Eligible
Customer
$1,051
PCE Eligible kWh ‐ Community Facility
Customers
79,566 Average PCE Payment per Eligible kWh $0.28
Total PCE Eligible kWh 458,104 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.51
Average Monthly PCE Eligible kWh per
Residential Customer
287 Last Reported PCE Level (per kWh) $0.27
Average Monthly PCE Eligible kWh per
Community Facility Customer
663 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
19 PCE Eligible kWh vs Total kWh Sold 52.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 925,369 Fuel Used (Gallons) 64,170
Non‐Diesel kWh Generated 0 Fuel Cost $168,844
Purchased kWh 0 Average Price of Fuel $2.61
Total Purchased & Generated 925,369 Fuel Cost per kWh sold $0.19
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.19
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 414,089 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
94.7%
Community Facility kWh Sold 211,882 Line Loss (%) 3.9%
Other kWh Sold (Non‐PCE) 250,564 Fuel Efficiency (kWh per Gallon of Diesel)14.42
Total kWh Sold 876,535 PH Consumption as % of Generation 1.4%
Powerhouse (PH) Consumption kWh 12,637
Total kWh Sold & PH Consumption 889,172
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 58 of 191
Egegik PCE
Utility: CITY OF EGEGIK
Reporting Period: 07/01/17..06/30/18
Community Population 85
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 81
Community Facility Customers 18
Other Customers (Non‐PCE) 24
Fiscal Year PCE Payments $86,230
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 122,535 Average Annual PCE Payment per Eligible
Customer
$871
PCE Eligible kWh ‐ Community Facility
Customers
71,400 Average PCE Payment per Eligible kWh $0.44
Total PCE Eligible kWh 193,935 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.65
Average Monthly PCE Eligible kWh per
Residential Customer
126 Last Reported PCE Level (per kWh) $0.47
Average Monthly PCE Eligible kWh per
Community Facility Customer
331 Effective Residential Rate (per kWh) $0.18
Average Monthly PCE Eligible Community
Facility kWh per Person
70 PCE Eligible kWh vs Total kWh Sold 35.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 613,843 Fuel Used (Gallons) 51,720
Non‐Diesel kWh Generated 0 Fuel Cost $143,970
Purchased kWh 0 Average Price of Fuel $2.78
Total Purchased & Generated 613,843 Fuel Cost per kWh sold $0.26
Annual Non‐Fuel Expenses $114,467
Non‐Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.47
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 141,425 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
89.7%
Community Facility kWh Sold 107,435 Line Loss (%) 6.3%
Other kWh Sold (Non‐PCE) 301,725 Fuel Efficiency (kWh per Gallon of Diesel)11.87
Total kWh Sold 550,585 PH Consumption as % of Generation 4.0%
Powerhouse (PH) Consumption kWh 24,298
Total kWh Sold & PH Consumption 574,883
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 59 of 191
Ekwok PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 113
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 52
Community Facility Customers 11
Other Customers (Non‐PCE) 15
Fiscal Year PCE Payments $69,277
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 174,011 Average Annual PCE Payment per Eligible
Customer
$1,100
PCE Eligible kWh ‐ Community Facility
Customers
25,835 Average PCE Payment per Eligible kWh $0.35
Total PCE Eligible kWh 199,846 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.56
Average Monthly PCE Eligible kWh per
Residential Customer
279 Last Reported PCE Level (per kWh) $0.31
Average Monthly PCE Eligible kWh per
Community Facility Customer
196 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
19 PCE Eligible kWh vs Total kWh Sold 48.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons) 0
Non‐Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $3.75
Total Purchased & Generated 0 Fuel Cost per kWh sold $0
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.00
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 217,594 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
$0
Community Facility kWh Sold 108,484 Line Loss (%) $0
Other kWh Sold (Non‐PCE) 82,191 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 408,269 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 408,269
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 60 of 191
Elfin Cove PCE
Utility: ELFIN COVE UTILITY COMMISSION
Reporting Period: 07/01/17..06/30/18
Community Population 44
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 47
Community Facility Customers 6
Other Customers (Non‐PCE) 26
Fiscal Year PCE Payments $24,347
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 54,301 Average Annual PCE Payment per Eligible
Customer
$459
PCE Eligible kWh ‐ Community Facility
Customers
8,834 Average PCE Payment per Eligible kWh $0.39
Total PCE Eligible kWh 63,135 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.68
Average Monthly PCE Eligible kWh per
Residential Customer
96 Last Reported PCE Level (per kWh) $0.41
Average Monthly PCE Eligible kWh per
Community Facility Customer
123 Effective Residential Rate (per kWh) $0.27
Average Monthly PCE Eligible Community
Facility kWh per Person
17 PCE Eligible kWh vs Total kWh Sold 21.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 348,455 Fuel Used (Gallons) 28,103
Non‐Diesel kWh Generated 0 Fuel Cost $95,678
Purchased kWh 0 Average Price of Fuel $3.40
Total Purchased & Generated 348,455 Fuel Cost per kWh sold $0.33
Annual Non‐Fuel Expenses $67,271
Non‐Fuel Expense per kWh Sold $0.23
Total Expense per kWh Sold $0.56
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 125,927 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
83.1%
Community Facility kWh Sold 8,920 Line Loss (%) 10.3%
Other kWh Sold (Non‐PCE) 154,641 Fuel Efficiency (kWh per Gallon of Diesel)12.40
Total kWh Sold 289,488 PH Consumption as % of Generation 6.7%
Powerhouse (PH) Consumption kWh 23,237
Total kWh Sold & PH Consumption 312,725
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 61 of 191
Elim PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 339
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 90
Community Facility Customers 11
Other Customers (Non‐PCE) 32
Fiscal Year PCE Payments $154,796
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 398,660 Average Annual PCE Payment per Eligible
Customer
$1,533
PCE Eligible kWh ‐ Community Facility
Customers
149,167 Average PCE Payment per Eligible kWh $0.28
Total PCE Eligible kWh 547,827 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.52
Average Monthly PCE Eligible kWh per
Residential Customer
369 Last Reported PCE Level (per kWh) $0.28
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,130 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
37 PCE Eligible kWh vs Total kWh Sold 45.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,293,051 Fuel Used (Gallons) 97,697
Non‐Diesel kWh Generated 0 Fuel Cost $264,489
Purchased kWh 0 Average Price of Fuel $2.75
Total Purchased & Generated 1,293,051 Fuel Cost per kWh sold $0.22
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.22
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 491,674 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
92.5%
Community Facility kWh Sold 261,003 Line Loss (%) 6.2%
Other kWh Sold (Non‐PCE) 443,053 Fuel Efficiency (kWh per Gallon of Diesel)13.24
Total kWh Sold 1,195,730 PH Consumption as % of Generation 1.3%
Powerhouse (PH) Consumption kWh 17,134
Total kWh Sold & PH Consumption 1,212,864
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 62 of 191
Emmonak PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 856
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 210
Community Facility Customers 22
Other Customers (Non‐PCE) 60
Fiscal Year PCE Payments $357,551
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 869,782 Average Annual PCE Payment per Eligible
Customer
$1,541
PCE Eligible kWh ‐ Community Facility
Customers
614,021 Average PCE Payment per Eligible kWh $0.24
Total PCE Eligible kWh 1,483,803 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.50
Average Monthly PCE Eligible kWh per
Residential Customer
345 Last Reported PCE Level (per kWh) $0.25
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,326 Effective Residential Rate (per kWh) $0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
60 PCE Eligible kWh vs Total kWh Sold 41.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 5,116,390 Fuel Used (Gallons) 359,562
Non‐Diesel kWh Generated 478,668 Fuel Cost $939,229
Purchased kWh 0 Average Price of Fuel $2.62
Total Purchased & Generated 5,595,058 Fuel Cost per kWh sold $0.26
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.26
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,067,009 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
64.1%
Community Facility kWh Sold 948,748 Line Loss (%) 33.2%
Other kWh Sold (Non‐PCE) 1,571,452 Fuel Efficiency (kWh per Gallon of Diesel)14.23
Total kWh Sold 3,587,209 PH Consumption as % of Generation 2.7%
Powerhouse (PH) Consumption kWh 148,746
Total kWh Sold & PH Consumption 3,735,955
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 63 of 191
False Pass PCE
Utility: CITY OF FALSE PASS
Reporting Period: 07/01/17..06/30/18
Community Population 73
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 29
Community Facility Customers 12
Other Customers (Non‐PCE) 19
Fiscal Year PCE Payments $14,953
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 72,799 Average Annual PCE Payment per Eligible
Customer
$365
PCE Eligible kWh ‐ Community Facility
Customers
56,106 Average PCE Payment per Eligible kWh $0.12
Total PCE Eligible kWh 128,905 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.43
Average Monthly PCE Eligible kWh per
Residential Customer
209 Last Reported PCE Level (per kWh) $0.12
Average Monthly PCE Eligible kWh per
Community Facility Customer
390 Effective Residential Rate (per kWh) $0.32
Average Monthly PCE Eligible Community
Facility kWh per Person
64 PCE Eligible kWh vs Total kWh Sold 24.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 647,989 Fuel Used (Gallons) 52,613
Non‐Diesel kWh Generated 0 Fuel Cost $121,336
Purchased kWh 0 Average Price of Fuel $2.31
Total Purchased & Generated 647,989 Fuel Cost per kWh sold $0.23
Annual Non‐Fuel Expenses $102,010
Non‐Fuel Expense per kWh Sold $0.19
Total Expense per kWh Sold $0.42
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 123,272 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
81.8%
Community Facility kWh Sold 68,978 Line Loss (%) 12.0%
Other kWh Sold (Non‐PCE) 337,602 Fuel Efficiency (kWh per Gallon of Diesel)12.32
Total kWh Sold 529,852 PH Consumption as % of Generation 6.2%
Powerhouse (PH) Consumption kWh 40,469
Total kWh Sold & PH Consumption 570,321
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 64 of 191
Fort Yukon PCE
Utility: GWITCHYAA ZHEE UTILITY COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 558
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 257
Community Facility Customers 17
Other Customers (Non‐PCE) 80
Fiscal Year PCE Payments $441,439
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 847,257 Average Annual PCE Payment per Eligible
Customer
$1,611
PCE Eligible kWh ‐ Community Facility
Customers
349,137 Average PCE Payment per Eligible kWh $0.37
Total PCE Eligible kWh 1,196,394 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.66
Average Monthly PCE Eligible kWh per
Residential Customer
275 Last Reported PCE Level (per kWh) $0.36
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,711 Effective Residential Rate (per kWh) $0.30
Average Monthly PCE Eligible Community
Facility kWh per Person
52 PCE Eligible kWh vs Total kWh Sold 47.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 3,217,833 Fuel Used (Gallons) 219,731
Non‐Diesel kWh Generated 0 Fuel Cost $1,288,503
Purchased kWh 0 Average Price of Fuel $5.86
Total Purchased & Generated 3,217,833 Fuel Cost per kWh sold $0.51
Annual Non‐Fuel Expenses $499,038
Non‐Fuel Expense per kWh Sold $0.20
Total Expense per kWh Sold $0.71
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,011,610 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
78.3%
Community Facility kWh Sold 353,703 Line Loss (%) 20.0%
Other kWh Sold (Non‐PCE) 1,152,975 Fuel Efficiency (kWh per Gallon of Diesel)14.64
Total kWh Sold 2,518,288 PH Consumption as % of Generation 1.7%
Powerhouse (PH) Consumption kWh 54,839
Total kWh Sold & PH Consumption 2,573,127
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 65 of 191
Galena PCE
Utility: CITY OF GALENA
Reporting Period: 07/01/17..06/30/18
Community Population 488
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 197
Community Facility Customers 14
Other Customers (Non‐PCE) 175
Fiscal Year PCE Payments $216,539
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 672,363 Average Annual PCE Payment per Eligible
Customer
$1,026
PCE Eligible kWh ‐ Community Facility
Customers
406,733 Average PCE Payment per Eligible kWh $0.20
Total PCE Eligible kWh 1,079,096 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.67
Average Monthly PCE Eligible kWh per
Residential Customer
284 Last Reported PCE Level (per kWh) $0.19
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,421 Effective Residential Rate (per kWh) $0.48
Average Monthly PCE Eligible Community
Facility kWh per Person
69 PCE Eligible kWh vs Total kWh Sold 21.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 5,704,098 Fuel Used (Gallons) 423,289
Non‐Diesel kWh Generated 0 Fuel Cost $947,652
Purchased kWh 0 Average Price of Fuel $2.24
Total Purchased & Generated 5,704,098 Fuel Cost per kWh sold $0.19
Annual Non‐Fuel Expenses $1,236,716
Non‐Fuel Expense per kWh Sold $0.25
Total Expense per kWh Sold $0.43
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 820,295 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
88.5%
Community Facility kWh Sold 601,631 Line Loss (%) 9.0%
Other kWh Sold (Non‐PCE) 3,624,581 Fuel Efficiency (kWh per Gallon of Diesel)13.48
Total kWh Sold 5,046,507 PH Consumption as % of Generation 2.5%
Powerhouse (PH) Consumption kWh 144,156
Total kWh Sold & PH Consumption 5,190,663
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 66 of 191
Gambell PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 721
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 162
Community Facility Customers 14
Other Customers (Non‐PCE) 36
Fiscal Year PCE Payments $222,755
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 631,487 Average Annual PCE Payment per Eligible
Customer
$1,266
PCE Eligible kWh ‐ Community Facility
Customers
221,527 Average PCE Payment per Eligible kWh $0.26
Total PCE Eligible kWh 853,014 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.51
Average Monthly PCE Eligible kWh per
Residential Customer
325 Last Reported PCE Level (per kWh) $0.24
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,319 Effective Residential Rate (per kWh) $0.27
Average Monthly PCE Eligible Community
Facility kWh per Person
26 PCE Eligible kWh vs Total kWh Sold 47.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,469,666 Fuel Used (Gallons) 115,453
Non‐Diesel kWh Generated 502,851 Fuel Cost $324,762
Purchased kWh 0 Average Price of Fuel $2.88
Total Purchased & Generated 1,972,517 Fuel Cost per kWh sold $0.18
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.18
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 753,045 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
90.8%
Community Facility kWh Sold 409,679 Line Loss (%) 4.2%
Other kWh Sold (Non‐PCE) 629,291 Fuel Efficiency (kWh per Gallon of Diesel)12.73
Total kWh Sold 1,792,015 PH Consumption as % of Generation 5.0%
Powerhouse (PH) Consumption kWh 97,919
Total kWh Sold & PH Consumption 1,889,934
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 67 of 191
Golovin PCE
Utility: GOLOVIN POWER UTILITIES
Reporting Period: 07/01/17..06/30/18
Community Population 182
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 49
Community Facility Customers 11
Other Customers (Non‐PCE) 43
Fiscal Year PCE Payments $45,451
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 223,044 Average Annual PCE Payment per Eligible
Customer
$758
PCE Eligible kWh ‐ Community Facility
Customers
128,348 Average PCE Payment per Eligible kWh $0.13
Total PCE Eligible kWh 351,392 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.38
Average Monthly PCE Eligible kWh per
Residential Customer
379 Last Reported PCE Level (per kWh) $0.13
Average Monthly PCE Eligible kWh per
Community Facility Customer
972 Effective Residential Rate (per kWh) $0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
59 PCE Eligible kWh vs Total kWh Sold 34.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,044,080 Fuel Used (Gallons) 80,611
Non‐Diesel kWh Generated 0 Fuel Cost $182,577
Purchased kWh 0 Average Price of Fuel $2.26
Total Purchased & Generated 1,044,080 Fuel Cost per kWh sold $0.18
Annual Non‐Fuel Expenses $155,315
Non‐Fuel Expense per kWh Sold $0.15
Total Expense per kWh Sold $0.33
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 269,216 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
97.4%
Community Facility kWh Sold 131,194 Line Loss (%) 2.6%
Other kWh Sold (Non‐PCE) 616,078 Fuel Efficiency (kWh per Gallon of Diesel)12.95
Total kWh Sold 1,016,488 PH Consumption as % of Generation 0.0%
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 1,016,488
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 68 of 191
Goodnews Bay PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 265
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 81
Community Facility Customers 10
Other Customers (Non‐PCE) 12
Fiscal Year PCE Payments $104,116
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 321,509 Average Annual PCE Payment per Eligible
Customer
$1,144
PCE Eligible kWh ‐ Community Facility
Customers
64,364 Average PCE Payment per Eligible kWh $0.27
Total PCE Eligible kWh 385,873 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.51
Average Monthly PCE Eligible kWh per
Residential Customer
331 Last Reported PCE Level (per kWh) $0.27
Average Monthly PCE Eligible kWh per
Community Facility Customer
536 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
20 PCE Eligible kWh vs Total kWh Sold 57.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 724,394 Fuel Used (Gallons) 54,055
Non‐Diesel kWh Generated 0 Fuel Cost $147,215
Purchased kWh 0 Average Price of Fuel $2.73
Total Purchased & Generated 724,394 Fuel Cost per kWh sold $0.22
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.22
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 382,846 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
93.0%
Community Facility kWh Sold 109,021 Line Loss (%) 4.9%
Other kWh Sold (Non‐PCE) 181,944 Fuel Efficiency (kWh per Gallon of Diesel)13.40
Total kWh Sold 673,811 PH Consumption as % of Generation 2.1%
Powerhouse (PH) Consumption kWh 15,333
Total kWh Sold & PH Consumption 689,144
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 69 of 191
Grayling PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 189
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 67
Community Facility Customers 10
Other Customers (Non‐PCE) 14
Fiscal Year PCE Payments $98,601
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 236,001 Average Annual PCE Payment per Eligible
Customer
$1,281
PCE Eligible kWh ‐ Community Facility
Customers
128,269 Average PCE Payment per Eligible kWh $0.27
Total PCE Eligible kWh 364,270 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.52
Average Monthly PCE Eligible kWh per
Residential Customer
294 Last Reported PCE Level (per kWh) $0.28
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,069 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
57 PCE Eligible kWh vs Total kWh Sold 63.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 620,803 Fuel Used (Gallons) 46,530
Non‐Diesel kWh Generated 0 Fuel Cost $119,394
Purchased kWh 0 Average Price of Fuel $2.51
Total Purchased & Generated 620,803 Fuel Cost per kWh sold $0.21
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.21
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 261,425 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
92.8%
Community Facility kWh Sold 194,477 Line Loss (%) 3.9%
Other kWh Sold (Non‐PCE) 120,194 Fuel Efficiency (kWh per Gallon of Diesel)13.34
Total kWh Sold 576,096 PH Consumption as % of Generation 3.3%
Powerhouse (PH) Consumption kWh 20,514
Total kWh Sold & PH Consumption 596,610
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 70 of 191
Gustavus PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 558
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 472
Community Facility Customers 5
Other Customers (Non‐PCE) 109
Fiscal Year PCE Payments $138,820
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 1,011,029 Average Annual PCE Payment per Eligible
Customer
$291
PCE Eligible kWh ‐ Community Facility
Customers
35,659 Average PCE Payment per Eligible kWh $0.13
Total PCE Eligible kWh 1,046,688 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.49
Average Monthly PCE Eligible kWh per
Residential Customer
179 Last Reported PCE Level (per kWh) $0.16
Average Monthly PCE Eligible kWh per
Community Facility Customer
594 Effective Residential Rate (per kWh) $0.33
Average Monthly PCE Eligible Community
Facility kWh per Person
5 PCE Eligible kWh vs Total kWh Sold 52.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 251,372 Fuel Used (Gallons) 19,127
Non‐Diesel kWh Generated 2,185,112 Fuel Cost $65,003
Purchased kWh 0 Average Price of Fuel $3.40
Total Purchased & Generated 2,436,484 Fuel Cost per kWh sold $0.03
Annual Non‐Fuel Expenses $760,190
Non‐Fuel Expense per kWh Sold $0.38
Total Expense per kWh Sold $0.41
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,267,350 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
82.0%
Community Facility kWh Sold 35,659 Line Loss (%) 15.5%
Other kWh Sold (Non‐PCE) 695,454 Fuel Efficiency (kWh per Gallon of Diesel)13.14
Total kWh Sold 1,998,463 PH Consumption as % of Generation 2.4%
Powerhouse (PH) Consumption kWh 59,206
Total kWh Sold & PH Consumption 2,057,669
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 71 of 191
Haines; Covenant Life PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 2523
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 1,131
Community Facility Customers 40
Other Customers (Non‐PCE) 366
Fiscal Year PCE Payments $145,533
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 3,711,831 Average Annual PCE Payment per Eligible
Customer
$124
PCE Eligible kWh ‐ Community Facility
Customers
957,649 Average PCE Payment per Eligible kWh $0.03
Total PCE Eligible kWh 4,669,480 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.28
Average Monthly PCE Eligible kWh per
Residential Customer
273 Last Reported PCE Level (per kWh) $0.04
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,995 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
32 PCE Eligible kWh vs Total kWh Sold 37.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,479,240 Fuel Used (Gallons) 109,691
Non‐Diesel kWh Generated 9,595,366 Fuel Cost $277,384
Purchased kWh 12,250,578 Average Price of Fuel $2.53
Total Purchased & Generated 23,325,184 Fuel Cost per kWh sold $0.02
Annual Non‐Fuel Expenses $2,085,896
Non‐Fuel Expense per kWh Sold $0.17
Total Expense per kWh Sold $0.19
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 5,528,723 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
53.2%
Community Facility kWh Sold 985,748 Line Loss (%) 45.3%
Other kWh Sold (Non‐PCE) 5,904,696 Fuel Efficiency (kWh per Gallon of Diesel)13.49
Total kWh Sold 12,419,167 PH Consumption as % of Generation 1.5%
Powerhouse (PH) Consumption kWh 342,680
Total kWh Sold & PH Consumption 12,761,847
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 72 of 191
Healy Lake PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 22
Last Reported Month June
No. of Monthly Payments Made 13
Residential Customers 7
Community Facility Customers 3
Other Customers (Non‐PCE) 1
Fiscal Year PCE Payments $6,231
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 10,474 Average Annual PCE Payment per Eligible
Customer
$623
PCE Eligible kWh ‐ Community Facility
Customers
7,815 Average PCE Payment per Eligible kWh $0.34
Total PCE Eligible kWh 18,289 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.00
Average Monthly PCE Eligible kWh per
Residential Customer
115 Last Reported PCE Level (per kWh) $0.68
Average Monthly PCE Eligible kWh per
Community Facility Customer
200 Effective Residential Rate (per kWh) $0.32
Average Monthly PCE Eligible Community
Facility kWh per Person
27 PCE Eligible kWh vs Total kWh Sold 57.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 41,371 Fuel Used (Gallons) 6,122
Non‐Diesel kWh Generated 0 Fuel Cost $20,410
Purchased kWh 0 Average Price of Fuel $3.33
Total Purchased & Generated 41,371 Fuel Cost per kWh sold $0.64
Annual Non‐Fuel Expenses $65,642
Non‐Fuel Expense per kWh Sold $2.07
Total Expense per kWh Sold $2.72
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 10,842 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
76.5%
Community Facility kWh Sold 10,972 Line Loss (%) 19.9%
Other kWh Sold (Non‐PCE) 9,850 Fuel Efficiency (kWh per Gallon of Diesel)6.76
Total kWh Sold 31,664 PH Consumption as % of Generation 3.5%
Powerhouse (PH) Consumption kWh 1,455
Total kWh Sold & PH Consumption 33,119
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 73 of 191
Hollis PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 112
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 128
Community Facility Customers 1
Other Customers (Non‐PCE) 28
Fiscal Year PCE Payments $11,392
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 398,507 Average Annual PCE Payment per Eligible
Customer
$88
PCE Eligible kWh ‐ Community Facility
Customers
4,080 Average PCE Payment per Eligible kWh $0.03
Total PCE Eligible kWh 402,587 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.29
Average Monthly PCE Eligible kWh per
Residential Customer
259 Last Reported PCE Level (per kWh) $0.04
Average Monthly PCE Eligible kWh per
Community Facility Customer
340 Effective Residential Rate (per kWh) $0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
3 PCE Eligible kWh vs Total kWh Sold 25.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons) 0
Non‐Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold $0
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.00
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 638,720 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
$0
Community Facility kWh Sold 4,080 Line Loss (%) $0
Other kWh Sold (Non‐PCE) 920,823 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 1,563,623 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 16,637
Total kWh Sold & PH Consumption 1,580,260
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 74 of 191
Holy Cross PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 155
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 78
Community Facility Customers 10
Other Customers (Non‐PCE) 13
Fiscal Year PCE Payments $98,706
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 259,135 Average Annual PCE Payment per Eligible
Customer
$1,122
PCE Eligible kWh ‐ Community Facility
Customers
99,765 Average PCE Payment per Eligible kWh $0.28
Total PCE Eligible kWh 358,900 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.51
Average Monthly PCE Eligible kWh per
Residential Customer
277 Last Reported PCE Level (per kWh) $0.27
Average Monthly PCE Eligible kWh per
Community Facility Customer
831 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
54 PCE Eligible kWh vs Total kWh Sold 60.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 622,217 Fuel Used (Gallons) 42,783
Non‐Diesel kWh Generated 0 Fuel Cost $106,588
Purchased kWh 0 Average Price of Fuel $2.53
Total Purchased & Generated 622,217 Fuel Cost per kWh sold $0.18
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.18
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 298,169 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
95.8%
Community Facility kWh Sold 184,992 Line Loss (%) 0.4%
Other kWh Sold (Non‐PCE) 113,229 Fuel Efficiency (kWh per Gallon of Diesel)14.54
Total kWh Sold 596,390 PH Consumption as % of Generation 3.8%
Powerhouse (PH) Consumption kWh 23,633
Total kWh Sold & PH Consumption 620,023
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 75 of 191
Hoonah PCE
Utility: INSIDE PASSAGE ELECTRIC
Reporting Period: 07/01/17..06/30/18
Community Population 793
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 377
Community Facility Customers 28
Other Customers (Non‐PCE) 76
Fiscal Year PCE Payments $613,082
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 1,384,370 Average Annual PCE Payment per Eligible
Customer
$1,514
PCE Eligible kWh ‐ Community Facility
Customers
630,574 Average PCE Payment per Eligible kWh $0.30
Total PCE Eligible kWh 2,014,944 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.56
Average Monthly PCE Eligible kWh per
Residential Customer
306 Last Reported PCE Level (per kWh) $0.31
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,877 Effective Residential Rate (per kWh) $0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
66 PCE Eligible kWh vs Total kWh Sold 48.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 3,486,555 Fuel Used (Gallons) 246,002
Non‐Diesel kWh Generated 1,140,373 Fuel Cost $603,533
Purchased kWh 0 Average Price of Fuel $2.45
Total Purchased & Generated 4,626,928 Fuel Cost per kWh sold $0.14
Annual Non‐Fuel Expenses $1,037,155
Non‐Fuel Expense per kWh Sold $0.25
Total Expense per kWh Sold $0.39
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,643,794 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
90.7%
Community Facility kWh Sold 721,705 Line Loss (%) 7.3%
Other kWh Sold (Non‐PCE) 1,833,433 Fuel Efficiency (kWh per Gallon of Diesel)14.17
Total kWh Sold 4,198,932 PH Consumption as % of Generation 1.9%
Powerhouse (PH) Consumption kWh 89,626
Total kWh Sold & PH Consumption 4,288,558
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 76 of 191
Hooper Bay PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 1188
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 273
Community Facility Customers 11
Other Customers (Non‐PCE) 60
Fiscal Year PCE Payments $342,048
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 1,094,454 Average Annual PCE Payment per Eligible
Customer
$1,204
PCE Eligible kWh ‐ Community Facility
Customers
257,811 Average PCE Payment per Eligible kWh $0.25
Total PCE Eligible kWh 1,352,265 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.49
Average Monthly PCE Eligible kWh per
Residential Customer
334 Last Reported PCE Level (per kWh) $0.24
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,953 Effective Residential Rate (per kWh) $0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
18 PCE Eligible kWh vs Total kWh Sold 41.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,783,379 Fuel Used (Gallons) 199,282
Non‐Diesel kWh Generated 637,294 Fuel Cost $517,331
Purchased kWh 0 Average Price of Fuel $2.53
Total Purchased & Generated 3,420,673 Fuel Cost per kWh sold $0.16
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.16
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,274,196 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
94.3%
Community Facility kWh Sold 815,542 Line Loss (%) 3.7%
Other kWh Sold (Non‐PCE) 1,136,731 Fuel Efficiency (kWh per Gallon of Diesel)13.97
Total kWh Sold 3,226,469 PH Consumption as % of Generation 2.0%
Powerhouse (PH) Consumption kWh 66,874
Total kWh Sold & PH Consumption 3,293,343
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 77 of 191
Hughes PCE
Utility: HUGHES POWER & LIGHT
Reporting Period: 07/01/17..06/30/18
Community Population 91
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 46
Community Facility Customers 3
Other Customers (Non‐PCE) 14
Fiscal Year PCE Payments $118,435
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 156,013 Average Annual PCE Payment per Eligible
Customer
$2,417
PCE Eligible kWh ‐ Community Facility
Customers
69,515 Average PCE Payment per Eligible kWh $0.53
Total PCE Eligible kWh 225,528 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.71
Average Monthly PCE Eligible kWh per
Residential Customer
283 Last Reported PCE Level (per kWh) $0.53
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,931 Effective Residential Rate (per kWh) $0.18
Average Monthly PCE Eligible Community
Facility kWh per Person
64 PCE Eligible kWh vs Total kWh Sold 57.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 443,922 Fuel Used (Gallons) 48,138
Non‐Diesel kWh Generated 0 Fuel Cost $216,646
Purchased kWh 0 Average Price of Fuel $4.50
Total Purchased & Generated 443,922 Fuel Cost per kWh sold $0.55
Annual Non‐Fuel Expenses $92,383
Non‐Fuel Expense per kWh Sold $0.24
Total Expense per kWh Sold $0.79
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 185,693 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
88.2%
Community Facility kWh Sold 70,507 Line Loss (%) 4.1%
Other kWh Sold (Non‐PCE) 135,218 Fuel Efficiency (kWh per Gallon of Diesel)9.22
Total kWh Sold 391,418 PH Consumption as % of Generation 7.7%
Powerhouse (PH) Consumption kWh 34,140
Total kWh Sold & PH Consumption 425,558
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 78 of 191
Huslia PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 326
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 102
Community Facility Customers 17
Other Customers (Non‐PCE) 22
Fiscal Year PCE Payments $161,373
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 407,791 Average Annual PCE Payment per Eligible
Customer
$1,356
PCE Eligible kWh ‐ Community Facility
Customers
136,136 Average PCE Payment per Eligible kWh $0.30
Total PCE Eligible kWh 543,927 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.54
Average Monthly PCE Eligible kWh per
Residential Customer
333 Last Reported PCE Level (per kWh) $0.29
Average Monthly PCE Eligible kWh per
Community Facility Customer
667 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
35 PCE Eligible kWh vs Total kWh Sold 50.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,128,295 Fuel Used (Gallons) 83,838
Non‐Diesel kWh Generated 0 Fuel Cost $234,897
Purchased kWh 0 Average Price of Fuel $2.78
Total Purchased & Generated 1,128,295 Fuel Cost per kWh sold $0.22
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.22
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 515,244 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
95.1%
Community Facility kWh Sold 240,300 Line Loss (%) 2.8%
Other kWh Sold (Non‐PCE) 317,655 Fuel Efficiency (kWh per Gallon of Diesel)13.46
Total kWh Sold 1,073,199 PH Consumption as % of Generation 2.1%
Powerhouse (PH) Consumption kWh 23,160
Total kWh Sold & PH Consumption 1,096,359
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 79 of 191
Hydaburg PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 404
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 121
Community Facility Customers 10
Other Customers (Non‐PCE) 50
Fiscal Year PCE Payments $18,076
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 522,160 Average Annual PCE Payment per Eligible
Customer
$138
PCE Eligible kWh ‐ Community Facility
Customers
124,898 Average PCE Payment per Eligible kWh $0.03
Total PCE Eligible kWh 647,058 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.29
Average Monthly PCE Eligible kWh per
Residential Customer
360 Last Reported PCE Level (per kWh) $0.04
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,041 Effective Residential Rate (per kWh) $0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
26 PCE Eligible kWh vs Total kWh Sold 39.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons) 0
Non‐Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold $0
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.00
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 731,004 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
$0
Community Facility kWh Sold 150,423 Line Loss (%) $0
Other kWh Sold (Non‐PCE) 770,382 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 1,651,809 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 30,675
Total kWh Sold & PH Consumption 1,682,484
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 80 of 191
Igiugig PCE
Utility: IGIUGIG ELECTRIC COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 53
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 28
Community Facility Customers 13
Other Customers (Non‐PCE) 11
Fiscal Year PCE Payments $77,138
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 84,073 Average Annual PCE Payment per Eligible
Customer
$1,881
PCE Eligible kWh ‐ Community Facility
Customers
44,160 Average PCE Payment per Eligible kWh $0.60
Total PCE Eligible kWh 128,233 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.92
Average Monthly PCE Eligible kWh per
Residential Customer
250 Last Reported PCE Level (per kWh) $0.60
Average Monthly PCE Eligible kWh per
Community Facility Customer
283 Effective Residential Rate (per kWh) $0.32
Average Monthly PCE Eligible Community
Facility kWh per Person
69 PCE Eligible kWh vs Total kWh Sold 50.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 325,326 Fuel Used (Gallons) 24,789
Non‐Diesel kWh Generated 0 Fuel Cost $145,023
Purchased kWh 0 Average Price of Fuel $5.85
Total Purchased & Generated 325,326 Fuel Cost per kWh sold $0.57
Annual Non‐Fuel Expenses $51,452
Non‐Fuel Expense per kWh Sold $0.20
Total Expense per kWh Sold $0.77
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 97,109 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
78.7%
Community Facility kWh Sold 65,760 Line Loss (%) 16.3%
Other kWh Sold (Non‐PCE) 93,166 Fuel Efficiency (kWh per Gallon of Diesel)13.12
Total kWh Sold 256,035 PH Consumption as % of Generation 5.0%
Powerhouse (PH) Consumption kWh 16,120
Total kWh Sold & PH Consumption 272,155
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 81 of 191
Iliamna Newhalen Nondalton PCE
Utility: ILIAMNA NEWHALEN NONDALTON
Reporting Period: 07/01/17..06/30/18
Community Population 441
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 192
Community Facility Customers 16
Other Customers (Non‐PCE) 95
Fiscal Year PCE Payments $350,472
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 589,578 Average Annual PCE Payment per Eligible
Customer
$1,685
PCE Eligible kWh ‐ Community Facility
Customers
297,956 Average PCE Payment per Eligible kWh $0.39
Total PCE Eligible kWh 887,534 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.65
Average Monthly PCE Eligible kWh per
Residential Customer
256 Last Reported PCE Level (per kWh) $0.39
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,552 Effective Residential Rate (per kWh) $0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
56 PCE Eligible kWh vs Total kWh Sold 30.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 102,490 Fuel Used (Gallons) 7,783
Non‐Diesel kWh Generated 3,594,343 Fuel Cost $36,349
Purchased kWh 0 Average Price of Fuel $4.67
Total Purchased & Generated 3,696,833 Fuel Cost per kWh sold $0.01
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.01
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 780,630 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
79.3%
Community Facility kWh Sold 314,141 Line Loss (%) 8.3%
Other kWh Sold (Non‐PCE) 1,835,414 Fuel Efficiency (kWh per Gallon of Diesel)13.17
Total kWh Sold 2,930,185 PH Consumption as % of Generation 12.4%
Powerhouse (PH) Consumption kWh 459,637
Total kWh Sold & PH Consumption 3,389,822
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 82 of 191
Kake PCE
Utility: INSIDE PASSAGE ELECTRIC
Reporting Period: 07/01/17..06/30/18
Community Population 605
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 238
Community Facility Customers 15
Other Customers (Non‐PCE) 55
Fiscal Year PCE Payments $298,322
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 787,631 Average Annual PCE Payment per Eligible
Customer
$1,179
PCE Eligible kWh ‐ Community Facility
Customers
192,659 Average PCE Payment per Eligible kWh $0.30
Total PCE Eligible kWh 980,290 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.56
Average Monthly PCE Eligible kWh per
Residential Customer
276 Last Reported PCE Level (per kWh) $0.31
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,070 Effective Residential Rate (per kWh) $0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
27 PCE Eligible kWh vs Total kWh Sold 49.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,242,369 Fuel Used (Gallons) 152,721
Non‐Diesel kWh Generated 0 Fuel Cost $372,245
Purchased kWh 0 Average Price of Fuel $2.44
Total Purchased & Generated 2,242,369 Fuel Cost per kWh sold $0.19
Annual Non‐Fuel Expenses $678,451
Non‐Fuel Expense per kWh Sold $0.34
Total Expense per kWh Sold $0.53
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 939,034 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
87.8%
Community Facility kWh Sold 192,659 Line Loss (%) 9.1%
Other kWh Sold (Non‐PCE) 837,125 Fuel Efficiency (kWh per Gallon of Diesel)14.68
Total kWh Sold 1,968,818 PH Consumption as % of Generation 3.1%
Powerhouse (PH) Consumption kWh 70,109
Total kWh Sold & PH Consumption 2,038,927
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 83 of 191
Kaktovik PCE
Utility: NORTH SLOPE BOROUGH
Reporting Period: 07/01/17..06/30/18
Community Population 262
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 77
Community Facility Customers 3
Other Customers (Non‐PCE) 51
Fiscal Year PCE Payments $6,126
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 166,826 Average Annual PCE Payment per Eligible
Customer
$77
PCE Eligible kWh ‐ Community Facility
Customers
68,796 Average PCE Payment per Eligible kWh $0.03
Total PCE Eligible kWh 235,622 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.21
Average Monthly PCE Eligible kWh per
Residential Customer
181 Last Reported PCE Level (per kWh) $0.00
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,911 Effective Residential Rate (per kWh) $0.21
Average Monthly PCE Eligible Community
Facility kWh per Person
22 PCE Eligible kWh vs Total kWh Sold 5.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 4,749,459 Fuel Used (Gallons) 369,889
Non‐Diesel kWh Generated 0 Fuel Cost $930,293
Purchased kWh 0 Average Price of Fuel $2.52
Total Purchased & Generated 4,749,459 Fuel Cost per kWh sold $0.22
Annual Non‐Fuel Expenses $1,124,172
Non‐Fuel Expense per kWh Sold $0.27
Total Expense per kWh Sold $0.49
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 706,910 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
87.9%
Community Facility kWh Sold 68,796 Line Loss (%) 6.4%
Other kWh Sold (Non‐PCE) 3,399,206 Fuel Efficiency (kWh per Gallon of Diesel)12.84
Total kWh Sold 4,174,912 PH Consumption as % of Generation 5.7%
Powerhouse (PH) Consumption kWh 270,947
Total kWh Sold & PH Consumption 4,445,859
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 84 of 191
Kaltag PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 172
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 68
Community Facility Customers 14
Other Customers (Non‐PCE) 23
Fiscal Year PCE Payments $94,795
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 245,313 Average Annual PCE Payment per Eligible
Customer
$1,156
PCE Eligible kWh ‐ Community Facility
Customers
85,861 Average PCE Payment per Eligible kWh $0.29
Total PCE Eligible kWh 331,174 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.52
Average Monthly PCE Eligible kWh per
Residential Customer
301 Last Reported PCE Level (per kWh) $0.28
Average Monthly PCE Eligible kWh per
Community Facility Customer
511 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
42 PCE Eligible kWh vs Total kWh Sold 51.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 695,291 Fuel Used (Gallons) 48,561
Non‐Diesel kWh Generated 2,472 Fuel Cost $124,596
Purchased kWh 0 Average Price of Fuel $2.56
Total Purchased & Generated 697,763 Fuel Cost per kWh sold $0.19
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.19
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 264,078 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
92.3%
Community Facility kWh Sold 143,490 Line Loss (%) 4.9%
Other kWh Sold (Non‐PCE) 236,151 Fuel Efficiency (kWh per Gallon of Diesel)14.32
Total kWh Sold 643,719 PH Consumption as % of Generation 2.8%
Powerhouse (PH) Consumption kWh 19,699
Total kWh Sold & PH Consumption 663,418
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 85 of 191
Karluk PCE
Utility: KARLUK IRA TRIBAL COUNCIL
Reporting Period: 07/01/17..06/30/18
Community Population 24
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 14
Community Facility Customers 4
Other Customers (Non‐PCE) 12
Fiscal Year PCE Payments $28,185
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 52,084 Average Annual PCE Payment per Eligible
Customer
$1,566
PCE Eligible kWh ‐ Community Facility
Customers
19,322 Average PCE Payment per Eligible kWh $0.39
Total PCE Eligible kWh 71,406 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.70
Average Monthly PCE Eligible kWh per
Residential Customer
310 Last Reported PCE Level (per kWh) $0.41
Average Monthly PCE Eligible kWh per
Community Facility Customer
403 Effective Residential Rate (per kWh) $0.29
Average Monthly PCE Eligible Community
Facility kWh per Person
67 PCE Eligible kWh vs Total kWh Sold 38.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 207,987 Fuel Used (Gallons) 19,254
Non‐Diesel kWh Generated 0 Fuel Cost $64,068
Purchased kWh 0 Average Price of Fuel $3.33
Total Purchased & Generated 207,987 Fuel Cost per kWh sold $0.34
Annual Non‐Fuel Expenses $55,520
Non‐Fuel Expense per kWh Sold $0.30
Total Expense per kWh Sold $0.64
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 63,763 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
90.1%
Community Facility kWh Sold 21,487 Line Loss (%) 8.5%
Other kWh Sold (Non‐PCE) 102,181 Fuel Efficiency (kWh per Gallon of Diesel)10.80
Total kWh Sold 187,431 PH Consumption as % of Generation 1.4%
Powerhouse (PH) Consumption kWh 2,826
Total kWh Sold & PH Consumption 190,257
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 86 of 191
Kasigluk PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 602
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 121
Community Facility Customers 12
Other Customers (Non‐PCE) 20
Fiscal Year PCE Payments $211,392
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 596,153 Average Annual PCE Payment per Eligible
Customer
$1,589
PCE Eligible kWh ‐ Community Facility
Customers
244,403 Average PCE Payment per Eligible kWh $0.25
Total PCE Eligible kWh 840,556 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.49
Average Monthly PCE Eligible kWh per
Residential Customer
411 Last Reported PCE Level (per kWh) $0.24
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,697 Effective Residential Rate (per kWh) $0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
34 PCE Eligible kWh vs Total kWh Sold 51.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,543,607 Fuel Used (Gallons) 187,019
Non‐Diesel kWh Generated 498,104 Fuel Cost $486,708
Purchased kWh 0 Average Price of Fuel $2.76
Total Purchased & Generated 3,041,711 Fuel Cost per kWh sold $0.30
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.30
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 749,953 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
54.0%
Community Facility kWh Sold 339,618 Line Loss (%) 42.5%
Other kWh Sold (Non‐PCE) 553,289 Fuel Efficiency (kWh per Gallon of Diesel)13.60
Total kWh Sold 1,642,860 PH Consumption as % of Generation 3.5%
Powerhouse (PH) Consumption kWh 105,959
Total kWh Sold & PH Consumption 1,748,819
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 87 of 191
Kiana PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 421
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 126
Community Facility Customers 15
Other Customers (Non‐PCE) 17
Fiscal Year PCE Payments $199,542
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 480,417 Average Annual PCE Payment per Eligible
Customer
$1,415
PCE Eligible kWh ‐ Community Facility
Customers
199,712 Average PCE Payment per Eligible kWh $0.29
Total PCE Eligible kWh 680,129 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.54
Average Monthly PCE Eligible kWh per
Residential Customer
318 Last Reported PCE Level (per kWh) $0.30
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,110 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
40 PCE Eligible kWh vs Total kWh Sold 45.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,628,797 Fuel Used (Gallons) 113,265
Non‐Diesel kWh Generated 0 Fuel Cost $320,891
Purchased kWh 0 Average Price of Fuel $2.76
Total Purchased & Generated 1,628,797 Fuel Cost per kWh sold $0.21
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.21
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 645,094 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
92.3%
Community Facility kWh Sold 255,027 Line Loss (%) 5.5%
Other kWh Sold (Non‐PCE) 603,135 Fuel Efficiency (kWh per Gallon of Diesel)14.38
Total kWh Sold 1,503,256 PH Consumption as % of Generation 2.2%
Powerhouse (PH) Consumption kWh 35,193
Total kWh Sold & PH Consumption 1,538,449
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 88 of 191
King Cove PCE
Utility: CITY OF KING COVE
Reporting Period: 07/01/17..06/30/18
Community Population 923
Last Reported Month October
No. of Monthly Payments Made 4
Residential Customers 192
Community Facility Customers 33
Other Customers (Non‐PCE) 219
Fiscal Year PCE Payments $0
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 224,004 Average Annual PCE Payment per Eligible
Customer
$0
PCE Eligible kWh ‐ Community Facility
Customers
250,453 Average PCE Payment per Eligible kWh $0.00
Total PCE Eligible kWh 474,457 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.30
Average Monthly PCE Eligible kWh per
Residential Customer
292 Last Reported PCE Level (per kWh) $0.00
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,897 Effective Residential Rate (per kWh) $0.30
Average Monthly PCE Eligible Community
Facility kWh per Person
68 PCE Eligible kWh vs Total kWh Sold 39.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 200,649 Fuel Used (Gallons) 13,704
Non‐Diesel kWh Generated 1,205,478 Fuel Cost $29,920
Purchased kWh 0 Average Price of Fuel $2.18
Total Purchased & Generated 1,406,127 Fuel Cost per kWh sold $0.02
Annual Non‐Fuel Expenses $25,654
Non‐Fuel Expense per kWh Sold $0.02
Total Expense per kWh Sold $0.05
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 288,878 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
85.7%
Community Facility kWh Sold 499,052 Line Loss (%) 11.1%
Other kWh Sold (Non‐PCE) 417,738 Fuel Efficiency (kWh per Gallon of Diesel)14.64
Total kWh Sold 1,205,668 PH Consumption as % of Generation 3.2%
Powerhouse (PH) Consumption kWh 44,333
Total kWh Sold & PH Consumption 1,250,001
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 89 of 191
Kipnuk PCE
Utility: KIPNUK LIGHT PLANT
Reporting Period: 07/01/17..06/30/18
Community Population 673
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 183
Community Facility Customers 6
Other Customers (Non‐PCE) 68
Fiscal Year PCE Payments $143,835
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 733,526 Average Annual PCE Payment per Eligible
Customer
$761
PCE Eligible kWh ‐ Community Facility
Customers
73,862 Average PCE Payment per Eligible kWh $0.18
Total PCE Eligible kWh 807,388 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.51
Average Monthly PCE Eligible kWh per
Residential Customer
334 Last Reported PCE Level (per kWh) $0.28
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,026 Effective Residential Rate (per kWh) $0.23
Average Monthly PCE Eligible Community
Facility kWh per Person
9 PCE Eligible kWh vs Total kWh Sold 44.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,940,748 Fuel Used (Gallons) 154,585
Non‐Diesel kWh Generated 0 Fuel Cost $371,752
Purchased kWh 0 Average Price of Fuel $2.40
Total Purchased & Generated 1,940,748 Fuel Cost per kWh sold $0.21
Annual Non‐Fuel Expenses $491,614
Non‐Fuel Expense per kWh Sold $0.27
Total Expense per kWh Sold $0.48
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 816,757 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
92.6%
Community Facility kWh Sold 201,784 Line Loss (%) 5.5%
Other kWh Sold (Non‐PCE) 777,900 Fuel Efficiency (kWh per Gallon of Diesel)12.55
Total kWh Sold 1,796,441 PH Consumption as % of Generation 1.9%
Powerhouse (PH) Consumption kWh 36,753
Total kWh Sold & PH Consumption 1,833,194
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 90 of 191
Kivalina PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 429
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 86
Community Facility Customers 10
Other Customers (Non‐PCE) 19
Fiscal Year PCE Payments $156,927
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 407,538 Average Annual PCE Payment per Eligible
Customer
$1,635
PCE Eligible kWh ‐ Community Facility
Customers
105,855 Average PCE Payment per Eligible kWh $0.31
Total PCE Eligible kWh 513,393 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.55
Average Monthly PCE Eligible kWh per
Residential Customer
395 Last Reported PCE Level (per kWh) $0.30
Average Monthly PCE Eligible kWh per
Community Facility Customer
882 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
21 PCE Eligible kWh vs Total kWh Sold 42.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,290,371 Fuel Used (Gallons) 91,192
Non‐Diesel kWh Generated 0 Fuel Cost $258,285
Purchased kWh 0 Average Price of Fuel $2.81
Total Purchased & Generated 1,290,371 Fuel Cost per kWh sold $0.21
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.21
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 540,786 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
94.4%
Community Facility kWh Sold 285,310 Line Loss (%) 2.9%
Other kWh Sold (Non‐PCE) 391,820 Fuel Efficiency (kWh per Gallon of Diesel)14.15
Total kWh Sold 1,217,916 PH Consumption as % of Generation 2.7%
Powerhouse (PH) Consumption kWh 34,402
Total kWh Sold & PH Consumption 1,252,318
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 91 of 191
Klawock PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 814
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 399
Community Facility Customers 24
Other Customers (Non‐PCE) 138
Fiscal Year PCE Payments $58,407
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 1,559,266 Average Annual PCE Payment per Eligible
Customer
$138
PCE Eligible kWh ‐ Community Facility
Customers
499,207 Average PCE Payment per Eligible kWh $0.03
Total PCE Eligible kWh 2,058,473 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.29
Average Monthly PCE Eligible kWh per
Residential Customer
326 Last Reported PCE Level (per kWh) $0.04
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,733 Effective Residential Rate (per kWh) $0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
51 PCE Eligible kWh vs Total kWh Sold 25.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons) 0
Non‐Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold $0
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.00
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 2,357,604 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
$0
Community Facility kWh Sold 501,742 Line Loss (%) $0
Other kWh Sold (Non‐PCE) 5,128,152 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 7,987,498 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 12,900
Total kWh Sold & PH Consumption 8,000,398
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Utility is intertied to another facility and does not generate power for sales to its customers.
Page 92 of 191
Klukwan PCE
Utility: INSIDE PASSAGE ELECTRIC
Reporting Period: 07/01/17..06/30/18
Community Population 95
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 48
Community Facility Customers 9
Other Customers (Non‐PCE) 8
Fiscal Year PCE Payments $78,784
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 179,428 Average Annual PCE Payment per Eligible
Customer
$1,382
PCE Eligible kWh ‐ Community Facility
Customers
79,660 Average PCE Payment per Eligible kWh $0.30
Total PCE Eligible kWh 259,088 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.56
Average Monthly PCE Eligible kWh per
Residential Customer
312 Last Reported PCE Level (per kWh) $0.31
Average Monthly PCE Eligible kWh per
Community Facility Customer
738 Effective Residential Rate (per kWh) $0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
70 PCE Eligible kWh vs Total kWh Sold 56.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons) 0
Non‐Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold $0
Annual Non‐Fuel Expenses $136,760
Non‐Fuel Expense per kWh Sold $0.30
Total Expense per kWh Sold $0.30
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 209,147 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
$0
Community Facility kWh Sold 169,036 Line Loss (%) $0
Other kWh Sold (Non‐PCE) 82,807 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 460,990 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 460,990
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 93 of 191
Kobuk PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 148
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 39
Community Facility Customers 3
Other Customers (Non‐PCE) 15
Fiscal Year PCE Payments $86,051
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 154,943 Average Annual PCE Payment per Eligible
Customer
$2,049
PCE Eligible kWh ‐ Community Facility
Customers
89,511 Average PCE Payment per Eligible kWh $0.35
Total PCE Eligible kWh 244,454 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.67
Average Monthly PCE Eligible kWh per
Residential Customer
331 Last Reported PCE Level (per kWh) $0.42
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,486 Effective Residential Rate (per kWh) $0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
50 PCE Eligible kWh vs Total kWh Sold 41.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons) 0
Non‐Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold $0
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.00
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 188,812 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
$0
Community Facility kWh Sold 155,555 Line Loss (%) $0
Other kWh Sold (Non‐PCE) 245,823 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 590,190 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 590,190
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 94 of 191
Kokhanok PCE
Utility: KOKHANOK VILLAGE COUNCIL
Reporting Period: 07/01/17..06/30/18
Community Population 152
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 59
Community Facility Customers 11
Other Customers (Non‐PCE) 11
Fiscal Year PCE Payments $147,200
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 169,972 Average Annual PCE Payment per Eligible
Customer
$2,103
PCE Eligible kWh ‐ Community Facility
Customers
70,360 Average PCE Payment per Eligible kWh $0.61
Total PCE Eligible kWh 240,332 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.90
Average Monthly PCE Eligible kWh per
Residential Customer
240 Last Reported PCE Level (per kWh) $0.66
Average Monthly PCE Eligible kWh per
Community Facility Customer
533 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
39 PCE Eligible kWh vs Total kWh Sold 61.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 452,200 Fuel Used (Gallons) 42,533
Non‐Diesel kWh Generated 0 Fuel Cost $189,679
Purchased kWh 0 Average Price of Fuel $4.46
Total Purchased & Generated 452,200 Fuel Cost per kWh sold $0.49
Annual Non‐Fuel Expenses $130,721
Non‐Fuel Expense per kWh Sold $0.34
Total Expense per kWh Sold $0.82
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 176,644 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
86.0%
Community Facility kWh Sold 70,397 Line Loss (%) 5.2%
Other kWh Sold (Non‐PCE) 141,898 Fuel Efficiency (kWh per Gallon of Diesel)10.63
Total kWh Sold 388,939 PH Consumption as % of Generation 8.8%
Powerhouse (PH) Consumption kWh 39,817
Total kWh Sold & PH Consumption 428,756
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 95 of 191
Koliganek PCE
Utility: NEW KOLIGANEK VILLAGE COUNCIL
Reporting Period: 07/01/17..06/30/18
Community Population 220
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 74
Community Facility Customers 9
Other Customers (Non‐PCE) 18
Fiscal Year PCE Payments $74,539
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 232,671 Average Annual PCE Payment per Eligible
Customer
$898
PCE Eligible kWh ‐ Community Facility
Customers
85,675 Average PCE Payment per Eligible kWh $0.23
Total PCE Eligible kWh 318,346 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.50
Average Monthly PCE Eligible kWh per
Residential Customer
262 Last Reported PCE Level (per kWh) $0.25
Average Monthly PCE Eligible kWh per
Community Facility Customer
793 Effective Residential Rate (per kWh) $0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
32 PCE Eligible kWh vs Total kWh Sold 47.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 755,503 Fuel Used (Gallons) 61,734
Non‐Diesel kWh Generated 0 Fuel Cost $162,298
Purchased kWh 0 Average Price of Fuel $2.63
Total Purchased & Generated 755,503 Fuel Cost per kWh sold $0.24
Annual Non‐Fuel Expenses $2,220
Non‐Fuel Expense per kWh Sold $0.00
Total Expense per kWh Sold $0.25
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 277,637 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
88.8%
Community Facility kWh Sold 86,950 Line Loss (%) 7.6%
Other kWh Sold (Non‐PCE) 306,552 Fuel Efficiency (kWh per Gallon of Diesel)12.24
Total kWh Sold 671,139 PH Consumption as % of Generation 3.6%
Powerhouse (PH) Consumption kWh 27,017
Total kWh Sold & PH Consumption 698,156
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 96 of 191
Kongiganak PCE
Utility: PUVURNAQ POWER COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 520
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 107
Community Facility Customers 5
Other Customers (Non‐PCE) 24
Fiscal Year PCE Payments $139,932
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 446,933 Average Annual PCE Payment per Eligible
Customer
$1,249
PCE Eligible kWh ‐ Community Facility
Customers
72,721 Average PCE Payment per Eligible kWh $0.27
Total PCE Eligible kWh 519,654 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.65
Average Monthly PCE Eligible kWh per
Residential Customer
348 Last Reported PCE Level (per kWh) $0.32
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,212 Effective Residential Rate (per kWh) $0.33
Average Monthly PCE Eligible Community
Facility kWh per Person
12 PCE Eligible kWh vs Total kWh Sold 46.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 798,130 Fuel Used (Gallons) 64,832
Non‐Diesel kWh Generated 438,326 Fuel Cost $176,644
Purchased kWh 159,981 Average Price of Fuel $2.72
Total Purchased & Generated 1,396,437 Fuel Cost per kWh sold $0.16
Annual Non‐Fuel Expenses $495,934
Non‐Fuel Expense per kWh Sold $0.44
Total Expense per kWh Sold $0.60
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 626,933 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
80.5%
Community Facility kWh Sold 89,569 Line Loss (%) 11.5%
Other kWh Sold (Non‐PCE) 408,080 Fuel Efficiency (kWh per Gallon of Diesel)12.31
Total kWh Sold 1,124,582 PH Consumption as % of Generation 7.9%
Powerhouse (PH) Consumption kWh 110,945
Total kWh Sold & PH Consumption 1,235,527
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 97 of 191
Kotlik PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 621
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 123
Community Facility Customers 11
Other Customers (Non‐PCE) 34
Fiscal Year PCE Payments $198,255
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 554,421 Average Annual PCE Payment per Eligible
Customer
$1,480
PCE Eligible kWh ‐ Community Facility
Customers
198,143 Average PCE Payment per Eligible kWh $0.26
Total PCE Eligible kWh 752,564 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.52
Average Monthly PCE Eligible kWh per
Residential Customer
376 Last Reported PCE Level (per kWh) $0.28
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,501 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
27 PCE Eligible kWh vs Total kWh Sold 41.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,954,180 Fuel Used (Gallons) 143,136
Non‐Diesel kWh Generated 0 Fuel Cost $366,219
Purchased kWh 0 Average Price of Fuel $2.56
Total Purchased & Generated 1,954,180 Fuel Cost per kWh sold $0.20
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.20
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 684,089 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
92.6%
Community Facility kWh Sold 249,481 Line Loss (%) 4.8%
Other kWh Sold (Non‐PCE) 875,476 Fuel Efficiency (kWh per Gallon of Diesel)13.65
Total kWh Sold 1,809,046 PH Consumption as % of Generation 2.6%
Powerhouse (PH) Consumption kWh 50,672
Total kWh Sold & PH Consumption 1,859,718
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 98 of 191
Kotzebue PCE
Utility: KOTZEBUE ELECTRIC ASSOCIATION
Reporting Period: 07/01/17..06/30/18
Community Population 3295
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 1,084
Community Facility Customers 26
Other Customers (Non‐PCE) 172
Fiscal Year PCE Payments $942,900
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 3,651,973 Average Annual PCE Payment per Eligible
Customer
$849
PCE Eligible kWh ‐ Community Facility
Customers
1,586,369 Average PCE Payment per Eligible kWh $0.18
Total PCE Eligible kWh 5,238,342 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.38
Average Monthly PCE Eligible kWh per
Residential Customer
281 Last Reported PCE Level (per kWh) $0.18
Average Monthly PCE Eligible kWh per
Community Facility Customer
5,085 Effective Residential Rate (per kWh) $0.20
Average Monthly PCE Eligible Community
Facility kWh per Person
40 PCE Eligible kWh vs Total kWh Sold 27.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 17,022,643 Fuel Used (Gallons) 1,179,262
Non‐Diesel kWh Generated 4,711,606 Fuel Cost $2,797,390
Purchased kWh 0 Average Price of Fuel $2.37
Total Purchased & Generated 21,734,249 Fuel Cost per kWh sold $0.15
Annual Non‐Fuel Expenses $686,784
Non‐Fuel Expense per kWh Sold $0.04
Total Expense per kWh Sold $0.18
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 6,711,252 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
88.4%
Community Facility kWh Sold 1,595,468 Line Loss (%) 9.5%
Other kWh Sold (Non‐PCE) 10,908,488 Fuel Efficiency (kWh per Gallon of Diesel)14.43
Total kWh Sold 19,215,208 PH Consumption as % of Generation 2.1%
Powerhouse (PH) Consumption kWh 445,679
Total kWh Sold & PH Consumption 19,660,887
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 99 of 191
Koyuk PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 331
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 93
Community Facility Customers 11
Other Customers (Non‐PCE) 28
Fiscal Year PCE Payments $146,576
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 393,311 Average Annual PCE Payment per Eligible
Customer
$1,409
PCE Eligible kWh ‐ Community Facility
Customers
148,842 Average PCE Payment per Eligible kWh $0.27
Total PCE Eligible kWh 542,153 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.51
Average Monthly PCE Eligible kWh per
Residential Customer
352 Last Reported PCE Level (per kWh) $0.27
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,128 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
37 PCE Eligible kWh vs Total kWh Sold 43.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,302,775 Fuel Used (Gallons) 91,755
Non‐Diesel kWh Generated 0 Fuel Cost $243,233
Purchased kWh 0 Average Price of Fuel $2.66
Total Purchased & Generated 1,302,775 Fuel Cost per kWh sold $0.20
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.20
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 499,705 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
94.8%
Community Facility kWh Sold 228,638 Line Loss (%) 4.0%
Other kWh Sold (Non‐PCE) 506,991 Fuel Efficiency (kWh per Gallon of Diesel)14.20
Total kWh Sold 1,235,334 PH Consumption as % of Generation 1.2%
Powerhouse (PH) Consumption kWh 15,930
Total kWh Sold & PH Consumption 1,251,264
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 100 of 191
Koyukuk PCE
Utility: CITY OF KOYUKUK
Reporting Period: 07/01/17..06/30/18
Community Population 97
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 67
Community Facility Customers 5
Other Customers (Non‐PCE) 15
Fiscal Year PCE Payments $35,420
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 92,869 Average Annual PCE Payment per Eligible
Customer
$492
PCE Eligible kWh ‐ Community Facility
Customers
28,030 Average PCE Payment per Eligible kWh $0.29
Total PCE Eligible kWh 120,899 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.95
Average Monthly PCE Eligible kWh per
Residential Customer
116 Last Reported PCE Level (per kWh) $0.28
Average Monthly PCE Eligible kWh per
Community Facility Customer
467 Effective Residential Rate (per kWh) $0.67
Average Monthly PCE Eligible Community
Facility kWh per Person
24 PCE Eligible kWh vs Total kWh Sold 53.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 310,293 Fuel Used (Gallons) 29,113
Non‐Diesel kWh Generated 0 Fuel Cost $74,971
Purchased kWh 0 Average Price of Fuel $2.58
Total Purchased & Generated 310,293 Fuel Cost per kWh sold $0.33
Annual Non‐Fuel Expenses $30,388
Non‐Fuel Expense per kWh Sold $0.14
Total Expense per kWh Sold $0.47
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 101,920 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
72.4%
Community Facility kWh Sold 28,030 Line Loss (%) 17.2%
Other kWh Sold (Non‐PCE) 94,704 Fuel Efficiency (kWh per Gallon of Diesel)10.66
Total kWh Sold 224,654 PH Consumption as % of Generation 10.4%
Powerhouse (PH) Consumption kWh 32,407
Total kWh Sold & PH Consumption 257,061
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 101 of 191
Kwethluk PCE
Utility: KWETHLUK INCORPORATED
Reporting Period: 07/01/17..06/30/18
Community Population 805
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 183
Community Facility Customers 2
Other Customers (Non‐PCE) 36
Fiscal Year PCE Payments $142,733
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 679,040 Average Annual PCE Payment per Eligible
Customer
$772
PCE Eligible kWh ‐ Community Facility
Customers
16,088 Average PCE Payment per Eligible kWh $0.21
Total PCE Eligible kWh 695,128 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.00
Average Monthly PCE Eligible kWh per
Residential Customer
309 Last Reported PCE Level (per kWh) $0.21
Average Monthly PCE Eligible kWh per
Community Facility Customer
670 Effective Residential Rate (per kWh) $0.79
Average Monthly PCE Eligible Community
Facility kWh per Person
2 PCE Eligible kWh vs Total kWh Sold 44.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,794,165 Fuel Used (Gallons) 138,417
Non‐Diesel kWh Generated 0 Fuel Cost $400,075
Purchased kWh 0 Average Price of Fuel $2.89
Total Purchased & Generated 1,794,165 Fuel Cost per kWh sold $0.25
Annual Non‐Fuel Expenses $166,890
Non‐Fuel Expense per kWh Sold $0.11
Total Expense per kWh Sold $0.36
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 838,929 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
87.8%
Community Facility kWh Sold 16,088 Line Loss (%) 10.1%
Other kWh Sold (Non‐PCE) 721,018 Fuel Efficiency (kWh per Gallon of Diesel)12.96
Total kWh Sold 1,576,035 PH Consumption as % of Generation 2.0%
Powerhouse (PH) Consumption kWh 36,306
Total kWh Sold & PH Consumption 1,612,341
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 102 of 191
Kwigillingok PCE
Utility: KWIG POWER COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 385
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 97
Community Facility Customers 3
Other Customers (Non‐PCE) 23
Fiscal Year PCE Payments $156,486
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 406,894 Average Annual PCE Payment per Eligible
Customer
$1,565
PCE Eligible kWh ‐ Community Facility
Customers
56,941 Average PCE Payment per Eligible kWh $0.34
Total PCE Eligible kWh 463,835 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.67
Average Monthly PCE Eligible kWh per
Residential Customer
350 Last Reported PCE Level (per kWh) $0.36
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,582 Effective Residential Rate (per kWh) $0.31
Average Monthly PCE Eligible Community
Facility kWh per Person
12 PCE Eligible kWh vs Total kWh Sold 38.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,042,090 Fuel Used (Gallons) 86,617
Non‐Diesel kWh Generated 306,521 Fuel Cost $242,426
Purchased kWh 20,792 Average Price of Fuel $2.80
Total Purchased & Generated 1,369,403 Fuel Cost per kWh sold $0.20
Annual Non‐Fuel Expenses $402,689
Non‐Fuel Expense per kWh Sold $0.34
Total Expense per kWh Sold $0.54
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 529,105 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
87.5%
Community Facility kWh Sold 56,941 Line Loss (%) 9.5%
Other kWh Sold (Non‐PCE) 611,709 Fuel Efficiency (kWh per Gallon of Diesel)12.03
Total kWh Sold 1,197,755 PH Consumption as % of Generation 3.1%
Powerhouse (PH) Consumption kWh 41,876
Total kWh Sold & PH Consumption 1,239,631
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 103 of 191
Larsen Bay PCE
Utility: LARSEN BAY UTILITY COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 77
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 52
Community Facility Customers 12
Other Customers (Non‐PCE) 30
Fiscal Year PCE Payments $0
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 103,173 Average Annual PCE Payment per Eligible
Customer
$0
PCE Eligible kWh ‐ Community Facility
Customers
65,240 Average PCE Payment per Eligible kWh $0.00
Total PCE Eligible kWh 168,413 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.41
Average Monthly PCE Eligible kWh per
Residential Customer
165 Last Reported PCE Level (per kWh) $0.00
Average Monthly PCE Eligible kWh per
Community Facility Customer
453 Effective Residential Rate (per kWh) $0.41
Average Monthly PCE Eligible Community
Facility kWh per Person
71 PCE Eligible kWh vs Total kWh Sold 20.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 28,935 Fuel Used (Gallons) 2,332
Non‐Diesel kWh Generated 971,111 Fuel Cost $8,192
Purchased kWh 0 Average Price of Fuel $3.51
Total Purchased & Generated 1,000,046 Fuel Cost per kWh sold $0.01
Annual Non‐Fuel Expenses $38,400
Non‐Fuel Expense per kWh Sold $0.05
Total Expense per kWh Sold $0.06
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 149,123 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
83.5%
Community Facility kWh Sold 154,705 Line Loss (%) 11.4%
Other kWh Sold (Non‐PCE) 530,820 Fuel Efficiency (kWh per Gallon of Diesel)12.41
Total kWh Sold 834,648 PH Consumption as % of Generation 5.1%
Powerhouse (PH) Consumption kWh 50,986
Total kWh Sold & PH Consumption 885,634
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 104 of 191
Levelock PCE
Utility: LEVELOCK ELECTRICAL COOP
Reporting Period: 07/01/17..06/30/18
Community Population 87
Last Reported Month May
No. of Monthly Payments Made 11
Residential Customers 34
Community Facility Customers 8
Other Customers (Non‐PCE) 30
Fiscal Year PCE Payments $51,309
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 105,418 Average Annual PCE Payment per Eligible
Customer
$1,222
PCE Eligible kWh ‐ Community Facility
Customers
35,002 Average PCE Payment per Eligible kWh $0.37
Total PCE Eligible kWh 140,420 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.85
Average Monthly PCE Eligible kWh per
Residential Customer
282 Last Reported PCE Level (per kWh) $0.37
Average Monthly PCE Eligible kWh per
Community Facility Customer
398 Effective Residential Rate (per kWh) $0.48
Average Monthly PCE Eligible Community
Facility kWh per Person
37 PCE Eligible kWh vs Total kWh Sold 43.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 404,972 Fuel Used (Gallons) 33,977
Non‐Diesel kWh Generated 0 Fuel Cost $92,815
Purchased kWh 0 Average Price of Fuel $2.73
Total Purchased & Generated 404,972 Fuel Cost per kWh sold $0.29
Annual Non‐Fuel Expenses $98,515
Non‐Fuel Expense per kWh Sold $0.31
Total Expense per kWh Sold $0.60
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 117,557 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
79.3%
Community Facility kWh Sold 35,776 Line Loss (%) 14.1%
Other kWh Sold (Non‐PCE) 167,657 Fuel Efficiency (kWh per Gallon of Diesel)11.92
Total kWh Sold 320,990 PH Consumption as % of Generation 6.6%
Powerhouse (PH) Consumption kWh 26,683
Total kWh Sold & PH Consumption 347,673
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 105 of 191
Lime Village PCE
Utility: LIME VILLAGE ELECTRIC UTILITY
Reporting Period: 07/01/17..06/30/18
Community Population 36
Last Reported Month June
No. of Monthly Payments Made 10
Residential Customers 17
Community Facility Customers 5
Other Customers (Non‐PCE) 2
Fiscal Year PCE Payments $17,931
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 10,928 Average Annual PCE Payment per Eligible
Customer
$815
PCE Eligible kWh ‐ Community Facility
Customers
11,952 Average PCE Payment per Eligible kWh $0.78
Total PCE Eligible kWh 22,880 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.77
Average Monthly PCE Eligible kWh per
Residential Customer
64 Last Reported PCE Level (per kWh) $0.78
Average Monthly PCE Eligible kWh per
Community Facility Customer
239 Effective Residential Rate (per kWh) $0.99
Average Monthly PCE Eligible Community
Facility kWh per Person
33 PCE Eligible kWh vs Total kWh Sold 48.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 76,998 Fuel Used (Gallons) 11,034
Non‐Diesel kWh Generated 0 Fuel Cost $73,378
Purchased kWh 0 Average Price of Fuel $6.65
Total Purchased & Generated 76,998 Fuel Cost per kWh sold $1.54
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $1.54
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 19,609 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
61.9%
Community Facility kWh Sold 12,652 Line Loss (%) 31.7%
Other kWh Sold (Non‐PCE) 15,410 Fuel Efficiency (kWh per Gallon of Diesel)6.98
Total kWh Sold 47,671 PH Consumption as % of Generation 6.4%
Powerhouse (PH) Consumption kWh 4,898
Total kWh Sold & PH Consumption 52,569
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 106 of 191
Lower Kalskag PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 288
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 83
Community Facility Customers 7
Other Customers (Non‐PCE) 11
Fiscal Year PCE Payments $103,056
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 292,133 Average Annual PCE Payment per Eligible
Customer
$1,145
PCE Eligible kWh ‐ Community Facility
Customers
91,111 Average PCE Payment per Eligible kWh $0.27
Total PCE Eligible kWh 383,244 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.50
Average Monthly PCE Eligible kWh per
Residential Customer
293 Last Reported PCE Level (per kWh) $0.26
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,085 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
26 PCE Eligible kWh vs Total kWh Sold 59.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons) 0
Non‐Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold $0
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.00
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 327,786 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
$0
Community Facility kWh Sold 206,020 Line Loss (%) $0
Other kWh Sold (Non‐PCE) 113,810 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 647,616 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 647,616
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 107 of 191
Manley Hot Springs PCE
Utility: TDX MANLEY GENERATING LLC
Reporting Period: 07/01/17..06/30/18
Community Population 127
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 85
Community Facility Customers 7
Other Customers (Non‐PCE) 21
Fiscal Year PCE Payments $116,365
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 163,974 Average Annual PCE Payment per Eligible
Customer
$1,265
PCE Eligible kWh ‐ Community Facility
Customers
31,566 Average PCE Payment per Eligible kWh $0.60
Total PCE Eligible kWh 195,540 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.80
Average Monthly PCE Eligible kWh per
Residential Customer
161 Last Reported PCE Level (per kWh) $0.50
Average Monthly PCE Eligible kWh per
Community Facility Customer
376 Effective Residential Rate (per kWh) $0.30
Average Monthly PCE Eligible Community
Facility kWh per Person
21 PCE Eligible kWh vs Total kWh Sold 43.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 558,735 Fuel Used (Gallons) 44,088
Non‐Diesel kWh Generated 0 Fuel Cost $101,788
Purchased kWh 0 Average Price of Fuel $2.31
Total Purchased & Generated 558,735 Fuel Cost per kWh sold $0.22
Annual Non‐Fuel Expenses $237,205
Non‐Fuel Expense per kWh Sold $0.52
Total Expense per kWh Sold $0.75
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 205,502 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
81.4%
Community Facility kWh Sold 31,737 Line Loss (%) 15.2%
Other kWh Sold (Non‐PCE) 217,468 Fuel Efficiency (kWh per Gallon of Diesel)12.67
Total kWh Sold 454,707 PH Consumption as % of Generation 3.5%
Powerhouse (PH) Consumption kWh 19,335
Total kWh Sold & PH Consumption 474,042
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 108 of 191
Manokotak PCE
Utility: MANOKOTAK POWER COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 496
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 152
Community Facility Customers 5
Other Customers (Non‐PCE) 35
Fiscal Year PCE Payments $140,091
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 512,887 Average Annual PCE Payment per Eligible
Customer
$892
PCE Eligible kWh ‐ Community Facility
Customers
63,959 Average PCE Payment per Eligible kWh $0.24
Total PCE Eligible kWh 576,846 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.55
Average Monthly PCE Eligible kWh per
Residential Customer
281 Last Reported PCE Level (per kWh) $0.24
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,066 Effective Residential Rate (per kWh) $0.31
Average Monthly PCE Eligible Community
Facility kWh per Person
11 PCE Eligible kWh vs Total kWh Sold 48.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,265,745 Fuel Used (Gallons) 107,244
Non‐Diesel kWh Generated 0 Fuel Cost $298,531
Purchased kWh 0 Average Price of Fuel $2.78
Total Purchased & Generated 1,265,745 Fuel Cost per kWh sold $0.25
Annual Non‐Fuel Expenses $250,901
Non‐Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.46
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 579,704 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
94.2%
Community Facility kWh Sold 64,931 Line Loss (%) 2.7%
Other kWh Sold (Non‐PCE) 547,370 Fuel Efficiency (kWh per Gallon of Diesel)11.80
Total kWh Sold 1,192,005 PH Consumption as % of Generation 3.1%
Powerhouse (PH) Consumption kWh 39,685
Total kWh Sold & PH Consumption 1,231,690
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 109 of 191
Marshall PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 459
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 106
Community Facility Customers 19
Other Customers (Non‐PCE) 21
Fiscal Year PCE Payments $158,657
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 475,545 Average Annual PCE Payment per Eligible
Customer
$1,269
PCE Eligible kWh ‐ Community Facility
Customers
167,472 Average PCE Payment per Eligible kWh $0.25
Total PCE Eligible kWh 643,017 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.49
Average Monthly PCE Eligible kWh per
Residential Customer
374 Last Reported PCE Level (per kWh) $0.25
Average Monthly PCE Eligible kWh per
Community Facility Customer
735 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
30 PCE Eligible kWh vs Total kWh Sold 47.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,455,817 Fuel Used (Gallons) 110,404
Non‐Diesel kWh Generated 0 Fuel Cost $265,605
Purchased kWh 0 Average Price of Fuel $2.98
Total Purchased & Generated 1,455,817 Fuel Cost per kWh sold $0.19
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.19
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 558,419 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
94.0%
Community Facility kWh Sold 311,163 Line Loss (%) 3.6%
Other kWh Sold (Non‐PCE) 498,301 Fuel Efficiency (kWh per Gallon of Diesel)13.19
Total kWh Sold 1,367,883 PH Consumption as % of Generation 2.5%
Powerhouse (PH) Consumption kWh 35,955
Total kWh Sold & PH Consumption 1,403,838
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 110 of 191
McGrath PCE
Utility: MCGRATH LIGHT & POWER
Reporting Period: 07/01/17..06/30/18
Community Population 302
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 179
Community Facility Customers 15
Other Customers (Non‐PCE) 88
Fiscal Year PCE Payments $223,822
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 448,264 Average Annual PCE Payment per Eligible
Customer
$1,154
PCE Eligible kWh ‐ Community Facility
Customers
192,923 Average PCE Payment per Eligible kWh $0.35
Total PCE Eligible kWh 641,187 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.79
Average Monthly PCE Eligible kWh per
Residential Customer
209 Last Reported PCE Level (per kWh) $0.34
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,072 Effective Residential Rate (per kWh) $0.45
Average Monthly PCE Eligible Community
Facility kWh per Person
53 PCE Eligible kWh vs Total kWh Sold 33.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,185,495 Fuel Used (Gallons) 152,818
Non‐Diesel kWh Generated 0 Fuel Cost $487,324
Purchased kWh 0 Average Price of Fuel $3.19
Total Purchased & Generated 2,185,495 Fuel Cost per kWh sold $0.25
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.25
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 491,567 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
88.9%
Community Facility kWh Sold 193,497 Line Loss (%) 8.1%
Other kWh Sold (Non‐PCE) 1,258,616 Fuel Efficiency (kWh per Gallon of Diesel)14.30
Total kWh Sold 1,943,680 PH Consumption as % of Generation 3.0%
Powerhouse (PH) Consumption kWh 65,476
Total kWh Sold & PH Consumption 2,009,156
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 111 of 191
Mekoryuk PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 215
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 89
Community Facility Customers 12
Other Customers (Non‐PCE) 25
Fiscal Year PCE Payments $107,830
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 290,836 Average Annual PCE Payment per Eligible
Customer
$1,068
PCE Eligible kWh ‐ Community Facility
Customers
87,772 Average PCE Payment per Eligible kWh $0.28
Total PCE Eligible kWh 378,608 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.52
Average Monthly PCE Eligible kWh per
Residential Customer
272 Last Reported PCE Level (per kWh) $0.26
Average Monthly PCE Eligible kWh per
Community Facility Customer
610 Effective Residential Rate (per kWh) $0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
34 PCE Eligible kWh vs Total kWh Sold 48.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 734,939 Fuel Used (Gallons) 54,617
Non‐Diesel kWh Generated 173,946 Fuel Cost $148,819
Purchased kWh 0 Average Price of Fuel $2.79
Total Purchased & Generated 908,885 Fuel Cost per kWh sold $0.19
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.19
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 304,925 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
86.1%
Community Facility kWh Sold 137,654 Line Loss (%) 7.2%
Other kWh Sold (Non‐PCE) 339,916 Fuel Efficiency (kWh per Gallon of Diesel)13.46
Total kWh Sold 782,495 PH Consumption as % of Generation 6.7%
Powerhouse (PH) Consumption kWh 61,127
Total kWh Sold & PH Consumption 843,622
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 112 of 191
Mentasta PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 113
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 48
Community Facility Customers 5
Other Customers (Non‐PCE) 20
Fiscal Year PCE Payments $46,341
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 132,127 Average Annual PCE Payment per Eligible
Customer
$874
PCE Eligible kWh ‐ Community Facility
Customers
20,702 Average PCE Payment per Eligible kWh $0.30
Total PCE Eligible kWh 152,829 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.66
Average Monthly PCE Eligible kWh per
Residential Customer
229 Last Reported PCE Level (per kWh) $0.36
Average Monthly PCE Eligible kWh per
Community Facility Customer
345 Effective Residential Rate (per kWh) $0.30
Average Monthly PCE Eligible Community
Facility kWh per Person
15 PCE Eligible kWh vs Total kWh Sold 41.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons) 0
Non‐Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold $0
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.00
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 136,751 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
$0
Community Facility kWh Sold 20,702 Line Loss (%) $0
Other kWh Sold (Non‐PCE) 215,639 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 373,092 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 373,092
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Utility is intertied to another facility and does not generate power for sales to its customers.
Page 113 of 191
Minto PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 212
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 73
Community Facility Customers 7
Other Customers (Non‐PCE) 18
Fiscal Year PCE Payments $93,834
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 247,785 Average Annual PCE Payment per Eligible
Customer
$1,173
PCE Eligible kWh ‐ Community Facility
Customers
128,563 Average PCE Payment per Eligible kWh $0.25
Total PCE Eligible kWh 376,348 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.49
Average Monthly PCE Eligible kWh per
Residential Customer
283 Last Reported PCE Level (per kWh) $0.25
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,531 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
51 PCE Eligible kWh vs Total kWh Sold 64.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 623,888 Fuel Used (Gallons) 45,639
Non‐Diesel kWh Generated 0 Fuel Cost $100,983
Purchased kWh 0 Average Price of Fuel $2.08
Total Purchased & Generated 623,888 Fuel Cost per kWh sold $0.17
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.17
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 298,985 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
93.9%
Community Facility kWh Sold 201,417 Line Loss (%) 4.4%
Other kWh Sold (Non‐PCE) 85,128 Fuel Efficiency (kWh per Gallon of Diesel)13.67
Total kWh Sold 585,530 PH Consumption as % of Generation 1.8%
Powerhouse (PH) Consumption kWh 10,974
Total kWh Sold & PH Consumption 596,504
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 114 of 191
Mt. Village PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 860
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 179
Community Facility Customers 18
Other Customers (Non‐PCE) 46
Fiscal Year PCE Payments $277,312
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 769,316 Average Annual PCE Payment per Eligible
Customer
$1,408
PCE Eligible kWh ‐ Community Facility
Customers
336,197 Average PCE Payment per Eligible kWh $0.25
Total PCE Eligible kWh 1,105,513 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.49
Average Monthly PCE Eligible kWh per
Residential Customer
358 Last Reported PCE Level (per kWh) $0.26
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,556 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
33 PCE Eligible kWh vs Total kWh Sold 43.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,747,912 Fuel Used (Gallons) 190,526
Non‐Diesel kWh Generated 0 Fuel Cost $499,265
Purchased kWh 0 Average Price of Fuel $2.57
Total Purchased & Generated 2,747,912 Fuel Cost per kWh sold $0.19
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.19
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 895,052 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
93.3%
Community Facility kWh Sold 501,632 Line Loss (%) 4.5%
Other kWh Sold (Non‐PCE) 1,166,939 Fuel Efficiency (kWh per Gallon of Diesel)14.42
Total kWh Sold 2,563,623 PH Consumption as % of Generation 2.2%
Powerhouse (PH) Consumption kWh 59,846
Total kWh Sold & PH Consumption 2,623,469
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 115 of 191
Naknek;S.Naknek;Kng Slmn PCE
Utility: NAKNEK ELECTRIC
Reporting Period: 07/01/17..06/30/18
Community Population 874
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 733
Community Facility Customers 38
Other Customers (Non‐PCE) 393
Fiscal Year PCE Payments $707,978
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 1,894,814 Average Annual PCE Payment per Eligible
Customer
$918
PCE Eligible kWh ‐ Community Facility
Customers
734,086 Average PCE Payment per Eligible kWh $0.27
Total PCE Eligible kWh 2,628,900 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.46
Average Monthly PCE Eligible kWh per
Residential Customer
215 Last Reported PCE Level (per kWh) $0.26
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,610 Effective Residential Rate (per kWh) $0.21
Average Monthly PCE Eligible Community
Facility kWh per Person
70 PCE Eligible kWh vs Total kWh Sold 12.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 22,848,137 Fuel Used (Gallons) 1,567,417
Non‐Diesel kWh Generated 0 Fuel Cost $3,061,769
Purchased kWh 0 Average Price of Fuel $1.95
Total Purchased & Generated 22,848,137 Fuel Cost per kWh sold $0.14
Annual Non‐Fuel Expenses $4,061,463
Non‐Fuel Expense per kWh Sold $0.19
Total Expense per kWh Sold $0.33
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 2,989,890 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
93.5%
Community Facility kWh Sold 1,107,561 Line Loss (%) 3.9%
Other kWh Sold (Non‐PCE) 17,268,707 Fuel Efficiency (kWh per Gallon of Diesel)14.58
Total kWh Sold 21,366,158 PH Consumption as % of Generation 2.5%
Powerhouse (PH) Consumption kWh 579,896
Total kWh Sold & PH Consumption 21,946,054
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 116 of 191
Napakiak PCE
Utility: NAPAKIAK IRCINRAQ
Reporting Period: 07/01/17..06/30/18
Community Population 355
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 107
Community Facility Customers 4
Other Customers (Non‐PCE) 24
Fiscal Year PCE Payments $111,969
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 350,348 Average Annual PCE Payment per Eligible
Customer
$1,009
PCE Eligible kWh ‐ Community Facility
Customers
38,618 Average PCE Payment per Eligible kWh $0.29
Total PCE Eligible kWh 388,966 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.70
Average Monthly PCE Eligible kWh per
Residential Customer
273 Last Reported PCE Level (per kWh) $0.31
Average Monthly PCE Eligible kWh per
Community Facility Customer
805 Effective Residential Rate (per kWh) $0.39
Average Monthly PCE Eligible Community
Facility kWh per Person
9 PCE Eligible kWh vs Total kWh Sold 61.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 217 Fuel Used (Gallons) 7,864
Non‐Diesel kWh Generated 0 Fuel Cost $2,282
Purchased kWh 675,302 Average Price of Fuel $0.29
Total Purchased & Generated 678,406 Fuel Cost per kWh sold $0.00
Annual Non‐Fuel Expenses $123,377
Non‐Fuel Expense per kWh Sold $0.19
Total Expense per kWh Sold $0.20
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 355,633 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
93.6%
Community Facility kWh Sold 38,618 Line Loss (%) 6.4%
Other kWh Sold (Non‐PCE) 240,659 Fuel Efficiency (kWh per Gallon of Diesel)0.03
Total kWh Sold 634,910 PH Consumption as % of Generation 0.0%
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 634,910
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 117 of 191
Napaskiak PCE
Utility: NAPASKIAK ELECTRIC UTILITY
Reporting Period: 07/01/17..06/30/18
Community Population 458
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 109
Community Facility Customers 8
Other Customers (Non‐PCE) 32
Fiscal Year PCE Payments $154,076
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 383,527 Average Annual PCE Payment per Eligible
Customer
$1,317
PCE Eligible kWh ‐ Community Facility
Customers
54,529 Average PCE Payment per Eligible kWh $0.35
Total PCE Eligible kWh 438,056 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.70
Average Monthly PCE Eligible kWh per
Residential Customer
293 Last Reported PCE Level (per kWh) $0.23
Average Monthly PCE Eligible kWh per
Community Facility Customer
568 Effective Residential Rate (per kWh) $0.47
Average Monthly PCE Eligible Community
Facility kWh per Person
10 PCE Eligible kWh vs Total kWh Sold 66.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,032,498 Fuel Used (Gallons) 83,480
Non‐Diesel kWh Generated 0 Fuel Cost $381,646
Purchased kWh 0 Average Price of Fuel $4.57
Total Purchased & Generated 1,032,498 Fuel Cost per kWh sold $0.58
Annual Non‐Fuel Expenses $38,095
Non‐Fuel Expense per kWh Sold $0.06
Total Expense per kWh Sold $0.64
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 408,651 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
63.6%
Community Facility kWh Sold 54,529 Line Loss (%) 34.5%
Other kWh Sold (Non‐PCE) 193,908 Fuel Efficiency (kWh per Gallon of Diesel)12.37
Total kWh Sold 657,088 PH Consumption as % of Generation 1.9%
Powerhouse (PH) Consumption kWh 19,637
Total kWh Sold & PH Consumption 676,725
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 118 of 191
Naukati PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 104
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 83
Community Facility Customers 0
Other Customers (Non‐PCE) 14
Fiscal Year PCE Payments $19,225
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 286,795 Average Annual PCE Payment per Eligible
Customer
$232
PCE Eligible kWh ‐ Community Facility
Customers
0 Average PCE Payment per Eligible kWh $0.07
Total PCE Eligible kWh 286,795 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.29
Average Monthly PCE Eligible kWh per
Residential Customer
288 Last Reported PCE Level (per kWh) $0.04
Average Monthly PCE Eligible kWh per
Community Facility Customer
0 Effective Residential Rate (per kWh) $0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
0 PCE Eligible kWh vs Total kWh Sold 50.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons) 0
Non‐Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold $0
Annual Non‐Fuel Expenses $61,123
Non‐Fuel Expense per kWh Sold $0.11
Total Expense per kWh Sold $0.11
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 419,922 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
$0
Community Facility kWh Sold 11,809 Line Loss (%) $0
Other kWh Sold (Non‐PCE) 131,214 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 562,945 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 17,256
Total kWh Sold & PH Consumption 580,201
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Utility is intertied to another facility and does not generate power for sales to its customers.
Page 119 of 191
Nelson Lagoon PCE
Utility: NELSON LAGOON ELECTRICAL COOP
Reporting Period: 07/01/17..06/30/18
Community Population 34
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 26
Community Facility Customers 5
Other Customers (Non‐PCE) 12
Fiscal Year PCE Payments $67,344
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 102,829 Average Annual PCE Payment per Eligible
Customer
$2,172
PCE Eligible kWh ‐ Community Facility
Customers
26,019 Average PCE Payment per Eligible kWh $0.52
Total PCE Eligible kWh 128,848 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.84
Average Monthly PCE Eligible kWh per
Residential Customer
330 Last Reported PCE Level (per kWh) $0.49
Average Monthly PCE Eligible kWh per
Community Facility Customer
434 Effective Residential Rate (per kWh) $0.35
Average Monthly PCE Eligible Community
Facility kWh per Person
64 PCE Eligible kWh vs Total kWh Sold 48.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 333,223 Fuel Used (Gallons) 30,534
Non‐Diesel kWh Generated 0 Fuel Cost $126,254
Purchased kWh 0 Average Price of Fuel $4.13
Total Purchased & Generated 333,223 Fuel Cost per kWh sold $0.48
Annual Non‐Fuel Expenses $61,171
Non‐Fuel Expense per kWh Sold $0.23
Total Expense per kWh Sold $0.71
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 138,081 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
79.2%
Community Facility kWh Sold 31,741 Line Loss (%) 16.1%
Other kWh Sold (Non‐PCE) 94,155 Fuel Efficiency (kWh per Gallon of Diesel)10.91
Total kWh Sold 263,977 PH Consumption as % of Generation 4.7%
Powerhouse (PH) Consumption kWh 15,570
Total kWh Sold & PH Consumption 279,547
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 120 of 191
New Stuyahok PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 497
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 105
Community Facility Customers 10
Other Customers (Non‐PCE) 37
Fiscal Year PCE Payments $180,701
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 471,493 Average Annual PCE Payment per Eligible
Customer
$1,571
PCE Eligible kWh ‐ Community Facility
Customers
78,390 Average PCE Payment per Eligible kWh $0.33
Total PCE Eligible kWh 549,883 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.56
Average Monthly PCE Eligible kWh per
Residential Customer
374 Last Reported PCE Level (per kWh) $0.31
Average Monthly PCE Eligible kWh per
Community Facility Customer
653 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
13 PCE Eligible kWh vs Total kWh Sold 42.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,798,449 Fuel Used (Gallons) 112,279
Non‐Diesel kWh Generated 0 Fuel Cost $360,372
Purchased kWh 0 Average Price of Fuel $3.26
Total Purchased & Generated 1,798,449 Fuel Cost per kWh sold $0.28
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.28
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 538,639 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
71.6%
Community Facility kWh Sold 233,724 Line Loss (%) 26.2%
Other kWh Sold (Non‐PCE) 514,962 Fuel Efficiency (kWh per Gallon of Diesel)16.02
Total kWh Sold 1,287,325 PH Consumption as % of Generation 2.2%
Powerhouse (PH) Consumption kWh 40,346
Total kWh Sold & PH Consumption 1,327,671
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 121 of 191
Newtok PCE
Utility: UNGUSRAQ POWER COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 372
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 71
Community Facility Customers 3
Other Customers (Non‐PCE) 23
Fiscal Year PCE Payments $110,937
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 243,863 Average Annual PCE Payment per Eligible
Customer
$1,499
PCE Eligible kWh ‐ Community Facility
Customers
21,116 Average PCE Payment per Eligible kWh $0.42
Total PCE Eligible kWh 264,979 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.80
Average Monthly PCE Eligible kWh per
Residential Customer
286 Last Reported PCE Level (per kWh) $0.42
Average Monthly PCE Eligible kWh per
Community Facility Customer
587 Effective Residential Rate (per kWh) $0.38
Average Monthly PCE Eligible Community
Facility kWh per Person
5 PCE Eligible kWh vs Total kWh Sold 67.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 418,864 Fuel Used (Gallons) 39,451
Non‐Diesel kWh Generated 0 Fuel Cost $113,384
Purchased kWh 0 Average Price of Fuel $2.87
Total Purchased & Generated 418,864 Fuel Cost per kWh sold $0.29
Annual Non‐Fuel Expenses $170,537
Non‐Fuel Expense per kWh Sold $0.44
Total Expense per kWh Sold $0.73
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 254,232 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
93.1%
Community Facility kWh Sold 21,116 Line Loss (%) 5.8%
Other kWh Sold (Non‐PCE) 114,750 Fuel Efficiency (kWh per Gallon of Diesel)10.62
Total kWh Sold 390,098 PH Consumption as % of Generation 1.1%
Powerhouse (PH) Consumption kWh 4,490
Total kWh Sold & PH Consumption 394,588
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 122 of 191
Nightmute PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 285
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 53
Community Facility Customers 8
Other Customers (Non‐PCE) 22
Fiscal Year PCE Payments $74,554
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 243,927 Average Annual PCE Payment per Eligible
Customer
$1,222
PCE Eligible kWh ‐ Community Facility
Customers
51,584 Average PCE Payment per Eligible kWh $0.25
Total PCE Eligible kWh 295,511 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.50
Average Monthly PCE Eligible kWh per
Residential Customer
384 Last Reported PCE Level (per kWh) $0.24
Average Monthly PCE Eligible kWh per
Community Facility Customer
537 Effective Residential Rate (per kWh) $0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
15 PCE Eligible kWh vs Total kWh Sold 36.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons) 0
Non‐Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold $0
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.00
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 275,583 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
$0
Community Facility kWh Sold 331,332 Line Loss (%) $0
Other kWh Sold (Non‐PCE) 199,588 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 806,503 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 806,503
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 123 of 191
Nikolai PCE
Utility: CITY OF NIKOLAI
Reporting Period: 07/01/17..06/30/18
Community Population 94
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 40
Community Facility Customers 7
Other Customers (Non‐PCE) 12
Fiscal Year PCE Payments $62,679
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 115,146 Average Annual PCE Payment per Eligible
Customer
$1,334
PCE Eligible kWh ‐ Community Facility
Customers
33,295 Average PCE Payment per Eligible kWh $0.42
Total PCE Eligible kWh 148,441 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.90
Average Monthly PCE Eligible kWh per
Residential Customer
240 Last Reported PCE Level (per kWh) $0.49
Average Monthly PCE Eligible kWh per
Community Facility Customer
396 Effective Residential Rate (per kWh) $0.41
Average Monthly PCE Eligible Community
Facility kWh per Person
30 PCE Eligible kWh vs Total kWh Sold 40.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 465,725 Fuel Used (Gallons) 43,501
Non‐Diesel kWh Generated 0 Fuel Cost $184,522
Purchased kWh 0 Average Price of Fuel $4.24
Total Purchased & Generated 465,725 Fuel Cost per kWh sold $0.50
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.50
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 134,774 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
79.7%
Community Facility kWh Sold 50,959 Line Loss (%) 17.0%
Other kWh Sold (Non‐PCE) 185,621 Fuel Efficiency (kWh per Gallon of Diesel)10.71
Total kWh Sold 371,354 PH Consumption as % of Generation 3.3%
Powerhouse (PH) Consumption kWh 15,398
Total kWh Sold & PH Consumption 386,752
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 124 of 191
Nikolski PCE
Utility: UMNAK POWER COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 13
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 13
Community Facility Customers 5
Other Customers (Non‐PCE) 8
Fiscal Year PCE Payments $29,310
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 40,125 Average Annual PCE Payment per Eligible
Customer
$1,628
PCE Eligible kWh ‐ Community Facility
Customers
10,920 Average PCE Payment per Eligible kWh $0.57
Total PCE Eligible kWh 51,045 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.75
Average Monthly PCE Eligible kWh per
Residential Customer
257 Last Reported PCE Level (per kWh) $0.57
Average Monthly PCE Eligible kWh per
Community Facility Customer
182 Effective Residential Rate (per kWh) $0.18
Average Monthly PCE Eligible Community
Facility kWh per Person
70 PCE Eligible kWh vs Total kWh Sold 30.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 207,951 Fuel Used (Gallons) 18,490
Non‐Diesel kWh Generated 0 Fuel Cost $116,191
Purchased kWh 0 Average Price of Fuel $6.28
Total Purchased & Generated 207,951 Fuel Cost per kWh sold $0.69
Annual Non‐Fuel Expenses $234,510
Non‐Fuel Expense per kWh Sold $1.40
Total Expense per kWh Sold $2.09
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 42,994 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
80.6%
Community Facility kWh Sold 34,954 Line Loss (%) 6.6%
Other kWh Sold (Non‐PCE) 89,591 Fuel Efficiency (kWh per Gallon of Diesel)11.25
Total kWh Sold 167,539 PH Consumption as % of Generation 12.8%
Powerhouse (PH) Consumption kWh 26,645
Total kWh Sold & PH Consumption 194,184
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 125 of 191
Noatak PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 583
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 116
Community Facility Customers 8
Other Customers (Non‐PCE) 26
Fiscal Year PCE Payments $413,702
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 599,409 Average Annual PCE Payment per Eligible
Customer
$3,336
PCE Eligible kWh ‐ Community Facility
Customers
194,958 Average PCE Payment per Eligible kWh $0.52
Total PCE Eligible kWh 794,367 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.79
Average Monthly PCE Eligible kWh per
Residential Customer
431 Last Reported PCE Level (per kWh) $0.53
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,031 Effective Residential Rate (per kWh) $0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
28 PCE Eligible kWh vs Total kWh Sold 45.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,900,741 Fuel Used (Gallons) 136,839
Non‐Diesel kWh Generated 0 Fuel Cost $825,033
Purchased kWh 0 Average Price of Fuel $5.99
Total Purchased & Generated 1,900,741 Fuel Cost per kWh sold $0.47
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.47
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 791,252 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
92.9%
Community Facility kWh Sold 302,881 Line Loss (%) 4.7%
Other kWh Sold (Non‐PCE) 671,553 Fuel Efficiency (kWh per Gallon of Diesel)13.89
Total kWh Sold 1,765,686 PH Consumption as % of Generation 2.4%
Powerhouse (PH) Consumption kWh 46,441
Total kWh Sold & PH Consumption 1,812,127
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 126 of 191
Nome PCE
Utility: NOME JOINT UTILITY SYSTEM
Reporting Period: 07/01/17..06/30/18
Community Population 3777
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 1,744
Community Facility Customers 79
Other Customers (Non‐PCE) 373
Fiscal Year PCE Payments $673,631
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 5,522,195 Average Annual PCE Payment per Eligible
Customer
$370
PCE Eligible kWh ‐ Community Facility
Customers
2,133,156 Average PCE Payment per Eligible kWh $0.09
Total PCE Eligible kWh 7,655,351 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.33
Average Monthly PCE Eligible kWh per
Residential Customer
264 Last Reported PCE Level (per kWh) $0.08
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,250 Effective Residential Rate (per kWh) $0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
47 PCE Eligible kWh vs Total kWh Sold 26.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 29,192,032 Fuel Used (Gallons) 1,830,717
Non‐Diesel kWh Generated 2,251,280 Fuel Cost $3,678,894
Purchased kWh 0 Average Price of Fuel $2.01
Total Purchased & Generated 31,443,312 Fuel Cost per kWh sold $0.13
Annual Non‐Fuel Expenses $6,921,043
Non‐Fuel Expense per kWh Sold $0.24
Total Expense per kWh Sold $0.37
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 8,418,313 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
91.4%
Community Facility kWh Sold 3,422,918 Line Loss (%) 4.2%
Other kWh Sold (Non‐PCE) 16,905,496 Fuel Efficiency (kWh per Gallon of Diesel)15.95
Total kWh Sold 28,746,727 PH Consumption as % of Generation 4.3%
Powerhouse (PH) Consumption kWh 1,366,913
Total kWh Sold & PH Consumption 30,113,640
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 127 of 191
Noorvik PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 644
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 131
Community Facility Customers 10
Other Customers (Non‐PCE) 34
Fiscal Year PCE Payments $249,141
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 630,432 Average Annual PCE Payment per Eligible
Customer
$1,767
PCE Eligible kWh ‐ Community Facility
Customers
336,030 Average PCE Payment per Eligible kWh $0.26
Total PCE Eligible kWh 966,462 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.51
Average Monthly PCE Eligible kWh per
Residential Customer
401 Last Reported PCE Level (per kWh) $0.27
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,800 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
43 PCE Eligible kWh vs Total kWh Sold 52.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,940,148 Fuel Used (Gallons) 137,322
Non‐Diesel kWh Generated 12,831 Fuel Cost $406,281
Purchased kWh 0 Average Price of Fuel $2.96
Total Purchased & Generated 1,952,979 Fuel Cost per kWh sold $0.22
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.22
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 858,926 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
94.1%
Community Facility kWh Sold 406,507 Line Loss (%) 4.3%
Other kWh Sold (Non‐PCE) 571,750 Fuel Efficiency (kWh per Gallon of Diesel)14.13
Total kWh Sold 1,837,183 PH Consumption as % of Generation 1.6%
Powerhouse (PH) Consumption kWh 31,371
Total kWh Sold & PH Consumption 1,868,554
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 128 of 191
Northway; Northway Village PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 151
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 87
Community Facility Customers 6
Other Customers (Non‐PCE) 29
Fiscal Year PCE Payments $115,669
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 270,719 Average Annual PCE Payment per Eligible
Customer
$1,244
PCE Eligible kWh ‐ Community Facility
Customers
75,225 Average PCE Payment per Eligible kWh $0.33
Total PCE Eligible kWh 345,944 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.70
Average Monthly PCE Eligible kWh per
Residential Customer
259 Last Reported PCE Level (per kWh) $0.40
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,045 Effective Residential Rate (per kWh) $0.31
Average Monthly PCE Eligible Community
Facility kWh per Person
42 PCE Eligible kWh vs Total kWh Sold 34.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,124,798 Fuel Used (Gallons) 88,319
Non‐Diesel kWh Generated 0 Fuel Cost $220,908
Purchased kWh 0 Average Price of Fuel $2.50
Total Purchased & Generated 1,124,798 Fuel Cost per kWh sold $0.22
Annual Non‐Fuel Expenses $211,650
Non‐Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.43
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 313,719 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
90.2%
Community Facility kWh Sold 75,225 Line Loss (%) 8.4%
Other kWh Sold (Non‐PCE) 625,660 Fuel Efficiency (kWh per Gallon of Diesel)12.74
Total kWh Sold 1,014,604 PH Consumption as % of Generation 1.4%
Powerhouse (PH) Consumption kWh 15,288
Total kWh Sold & PH Consumption 1,029,892
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 129 of 191
Nuiqsut PCE
Utility: NORTH SLOPE BOROUGH
Reporting Period: 07/01/17..06/30/18
Community Population 446
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 112
Community Facility Customers 3
Other Customers (Non‐PCE) 74
Fiscal Year PCE Payments $9,466
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 457,000 Average Annual PCE Payment per Eligible
Customer
$82
PCE Eligible kWh ‐ Community Facility
Customers
98,730 Average PCE Payment per Eligible kWh $0.02
Total PCE Eligible kWh 555,730 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.08
Average Monthly PCE Eligible kWh per
Residential Customer
340 Last Reported PCE Level (per kWh) $0.00
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,743 Effective Residential Rate (per kWh) $0.08
Average Monthly PCE Eligible Community
Facility kWh per Person
18 PCE Eligible kWh vs Total kWh Sold 9.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 548,144 Fuel Used (Gallons) 50,333
Non‐Diesel kWh Generated 6,572,967 Fuel Cost $199,416
Purchased kWh 0 Average Price of Fuel $3.96
Total Purchased & Generated 7,121,111 Fuel Cost per kWh sold $0.03
Annual Non‐Fuel Expenses $1,063,648
Non‐Fuel Expense per kWh Sold $0.19
Total Expense per kWh Sold $0.22
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 999,167 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
80.1%
Community Facility kWh Sold 98,730 Line Loss (%) 14.4%
Other kWh Sold (Non‐PCE) 4,609,200 Fuel Efficiency (kWh per Gallon of Diesel)10.89
Total kWh Sold 5,707,097 PH Consumption as % of Generation 5.4%
Powerhouse (PH) Consumption kWh 386,442
Total kWh Sold & PH Consumption 6,093,539
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 130 of 191
Nulato PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 246
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 107
Community Facility Customers 18
Other Customers (Non‐PCE) 16
Fiscal Year PCE Payments $161,997
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 391,840 Average Annual PCE Payment per Eligible
Customer
$1,296
PCE Eligible kWh ‐ Community Facility
Customers
188,275 Average PCE Payment per Eligible kWh $0.28
Total PCE Eligible kWh 580,115 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.52
Average Monthly PCE Eligible kWh per
Residential Customer
305 Last Reported PCE Level (per kWh) $0.28
Average Monthly PCE Eligible kWh per
Community Facility Customer
872 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
64 PCE Eligible kWh vs Total kWh Sold 61.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,024,460 Fuel Used (Gallons) 67,625
Non‐Diesel kWh Generated 0 Fuel Cost $163,189
Purchased kWh 0 Average Price of Fuel $2.40
Total Purchased & Generated 1,024,460 Fuel Cost per kWh sold $0.17
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.17
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 464,300 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
92.1%
Community Facility kWh Sold 255,348 Line Loss (%) 6.6%
Other kWh Sold (Non‐PCE) 224,252 Fuel Efficiency (kWh per Gallon of Diesel)15.15
Total kWh Sold 943,900 PH Consumption as % of Generation 1.3%
Powerhouse (PH) Consumption kWh 13,165
Total kWh Sold & PH Consumption 957,065
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 131 of 191
Nunam Iqua PCE
Utility: NUNAM IQUA ELECTRIC COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 201
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 43
Community Facility Customers 5
Other Customers (Non‐PCE) 11
Fiscal Year PCE Payments $44,742
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 186,136 Average Annual PCE Payment per Eligible
Customer
$932
PCE Eligible kWh ‐ Community Facility
Customers
138,894 Average PCE Payment per Eligible kWh $0.14
Total PCE Eligible kWh 325,030 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.40
Average Monthly PCE Eligible kWh per
Residential Customer
361 Last Reported PCE Level (per kWh) $0.19
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,315 Effective Residential Rate (per kWh) $0.20
Average Monthly PCE Eligible Community
Facility kWh per Person
58 PCE Eligible kWh vs Total kWh Sold 45.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 773,657 Fuel Used (Gallons) 61,076
Non‐Diesel kWh Generated 0 Fuel Cost $152,016
Purchased kWh 0 Average Price of Fuel $2.49
Total Purchased & Generated 773,657 Fuel Cost per kWh sold $0.21
Annual Non‐Fuel Expenses $110,945
Non‐Fuel Expense per kWh Sold $0.15
Total Expense per kWh Sold $0.37
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 206,290 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
93.0%
Community Facility kWh Sold 141,889 Line Loss (%) 3.6%
Other kWh Sold (Non‐PCE) 371,342 Fuel Efficiency (kWh per Gallon of Diesel)12.67
Total kWh Sold 719,521 PH Consumption as % of Generation 3.4%
Powerhouse (PH) Consumption kWh 26,134
Total kWh Sold & PH Consumption 745,655
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 132 of 191
Nunapitchuk PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 584
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 129
Community Facility Customers 12
Other Customers (Non‐PCE) 25
Fiscal Year PCE Payments $169,711
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 564,315 Average Annual PCE Payment per Eligible
Customer
$1,204
PCE Eligible kWh ‐ Community Facility
Customers
94,782 Average PCE Payment per Eligible kWh $0.26
Total PCE Eligible kWh 659,097 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.49
Average Monthly PCE Eligible kWh per
Residential Customer
365 Last Reported PCE Level (per kWh) $0.24
Average Monthly PCE Eligible kWh per
Community Facility Customer
658 Effective Residential Rate (per kWh) $0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
14 PCE Eligible kWh vs Total kWh Sold 55.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons) 0
Non‐Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold $0
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.00
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 660,799 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
$0
Community Facility kWh Sold 168,031 Line Loss (%) $0
Other kWh Sold (Non‐PCE) 366,809 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 1,195,639 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 1,195,639
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 133 of 191
Old Harbor PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 231
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 99
Community Facility Customers 12
Other Customers (Non‐PCE) 24
Fiscal Year PCE Payments $132,744
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 328,389 Average Annual PCE Payment per Eligible
Customer
$1,196
PCE Eligible kWh ‐ Community Facility
Customers
136,967 Average PCE Payment per Eligible kWh $0.29
Total PCE Eligible kWh 465,356 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.55
Average Monthly PCE Eligible kWh per
Residential Customer
276 Last Reported PCE Level (per kWh) $0.31
Average Monthly PCE Eligible kWh per
Community Facility Customer
951 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
49 PCE Eligible kWh vs Total kWh Sold 62.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 823,013 Fuel Used (Gallons) 54,865
Non‐Diesel kWh Generated 0 Fuel Cost $153,274
Purchased kWh 0 Average Price of Fuel $2.69
Total Purchased & Generated 823,013 Fuel Cost per kWh sold $0.20
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.20
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 410,279 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
90.9%
Community Facility kWh Sold 225,317 Line Loss (%) 4.6%
Other kWh Sold (Non‐PCE) 112,493 Fuel Efficiency (kWh per Gallon of Diesel)15.00
Total kWh Sold 748,089 PH Consumption as % of Generation 4.5%
Powerhouse (PH) Consumption kWh 36,981
Total kWh Sold & PH Consumption 785,070
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 134 of 191
Ouzinkie PCE
Utility: CITY OF OUZINKIE
Reporting Period: 07/01/17..06/30/18
Community Population 159
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 74
Community Facility Customers 14
Other Customers (Non‐PCE) 22
Fiscal Year PCE Payments $43,588
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 234,026 Average Annual PCE Payment per Eligible
Customer
$495
PCE Eligible kWh ‐ Community Facility
Customers
116,303 Average PCE Payment per Eligible kWh $0.12
Total PCE Eligible kWh 350,329 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.48
Average Monthly PCE Eligible kWh per
Residential Customer
264 Last Reported PCE Level (per kWh) $0.11
Average Monthly PCE Eligible kWh per
Community Facility Customer
692 Effective Residential Rate (per kWh) $0.37
Average Monthly PCE Eligible Community
Facility kWh per Person
61 PCE Eligible kWh vs Total kWh Sold 56.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 386,053 Fuel Used (Gallons) 31,349
Non‐Diesel kWh Generated 291,848 Fuel Cost $87,075
Purchased kWh 0 Average Price of Fuel $2.78
Total Purchased & Generated 677,901 Fuel Cost per kWh sold $0.14
Annual Non‐Fuel Expenses $118,698
Non‐Fuel Expense per kWh Sold $0.19
Total Expense per kWh Sold $0.33
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 262,032 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
91.2%
Community Facility kWh Sold 161,338 Line Loss (%) 2.5%
Other kWh Sold (Non‐PCE) 195,203 Fuel Efficiency (kWh per Gallon of Diesel)12.31
Total kWh Sold 618,573 PH Consumption as % of Generation 6.3%
Powerhouse (PH) Consumption kWh 42,519
Total kWh Sold & PH Consumption 661,092
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 135 of 191
Pedro Bay PCE
Utility: PEDRO BAY VILLAGE COUNCIL
Reporting Period: 07/01/17..06/30/18
Community Population 32
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 22
Community Facility Customers 4
Other Customers (Non‐PCE) 11
Fiscal Year PCE Payments $21,954
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 40,138 Average Annual PCE Payment per Eligible
Customer
$844
PCE Eligible kWh ‐ Community Facility
Customers
20,966 Average PCE Payment per Eligible kWh $0.36
Total PCE Eligible kWh 61,104 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.82
Average Monthly PCE Eligible kWh per
Residential Customer
152 Last Reported PCE Level (per kWh) $0.37
Average Monthly PCE Eligible kWh per
Community Facility Customer
437 Effective Residential Rate (per kWh) $0.45
Average Monthly PCE Eligible Community
Facility kWh per Person
55 PCE Eligible kWh vs Total kWh Sold 37.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 192,353 Fuel Used (Gallons) 18,031
Non‐Diesel kWh Generated 0 Fuel Cost $67,329
Purchased kWh 0 Average Price of Fuel $3.73
Total Purchased & Generated 192,353 Fuel Cost per kWh sold $0.42
Annual Non‐Fuel Expenses $35,136
Non‐Fuel Expense per kWh Sold $0.22
Total Expense per kWh Sold $0.63
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 45,851 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
84.1%
Community Facility kWh Sold 21,238 Line Loss (%) 9.4%
Other kWh Sold (Non‐PCE) 94,751 Fuel Efficiency (kWh per Gallon of Diesel)10.67
Total kWh Sold 161,840 PH Consumption as % of Generation 6.4%
Powerhouse (PH) Consumption kWh 12,389
Total kWh Sold & PH Consumption 174,229
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 136 of 191
Pilot Point PCE
Utility: PILOT POINT ELECTRIC UTILITY
Reporting Period: 07/01/17..06/30/18
Community Population 74
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 47
Community Facility Customers 10
Other Customers (Non‐PCE) 23
Fiscal Year PCE Payments $51,704
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 116,317 Average Annual PCE Payment per Eligible
Customer
$907
PCE Eligible kWh ‐ Community Facility
Customers
60,297 Average PCE Payment per Eligible kWh $0.29
Total PCE Eligible kWh 176,614 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.60
Average Monthly PCE Eligible kWh per
Residential Customer
206 Last Reported PCE Level (per kWh) $0.29
Average Monthly PCE Eligible kWh per
Community Facility Customer
502 Effective Residential Rate (per kWh) $0.31
Average Monthly PCE Eligible Community
Facility kWh per Person
68 PCE Eligible kWh vs Total kWh Sold 44.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 479,371 Fuel Used (Gallons) 46,126
Non‐Diesel kWh Generated 0 Fuel Cost $123,817
Purchased kWh 0 Average Price of Fuel $2.68
Total Purchased & Generated 479,371 Fuel Cost per kWh sold $0.31
Annual Non‐Fuel Expenses $12,063
Non‐Fuel Expense per kWh Sold $0.03
Total Expense per kWh Sold $0.34
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 142,446 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
83.7%
Community Facility kWh Sold 63,503 Line Loss (%) 11.3%
Other kWh Sold (Non‐PCE) 195,209 Fuel Efficiency (kWh per Gallon of Diesel)10.39
Total kWh Sold 401,158 PH Consumption as % of Generation 5.1%
Powerhouse (PH) Consumption kWh 24,247
Total kWh Sold & PH Consumption 425,405
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 137 of 191
Pilot Station PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 647
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 136
Community Facility Customers 13
Other Customers (Non‐PCE) 23
Fiscal Year PCE Payments $234,423
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 555,834 Average Annual PCE Payment per Eligible
Customer
$1,573
PCE Eligible kWh ‐ Community Facility
Customers
277,287 Average PCE Payment per Eligible kWh $0.28
Total PCE Eligible kWh 833,121 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.52
Average Monthly PCE Eligible kWh per
Residential Customer
341 Last Reported PCE Level (per kWh) $0.28
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,777 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
36 PCE Eligible kWh vs Total kWh Sold 46.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,878,765 Fuel Used (Gallons) 141,985
Non‐Diesel kWh Generated 0 Fuel Cost $352,925
Purchased kWh 0 Average Price of Fuel $2.44
Total Purchased & Generated 1,878,765 Fuel Cost per kWh sold $0.20
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.20
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 660,368 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
94.7%
Community Facility kWh Sold 350,987 Line Loss (%) 4.1%
Other kWh Sold (Non‐PCE) 767,222 Fuel Efficiency (kWh per Gallon of Diesel)13.23
Total kWh Sold 1,778,577 PH Consumption as % of Generation 1.2%
Powerhouse (PH) Consumption kWh 22,819
Total kWh Sold & PH Consumption 1,801,396
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 138 of 191
Pitkas Point PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 117
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 29
Community Facility Customers 5
Other Customers (Non‐PCE) 5
Fiscal Year PCE Payments $52,887
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 118,560 Average Annual PCE Payment per Eligible
Customer
$1,555
PCE Eligible kWh ‐ Community Facility
Customers
83,088 Average PCE Payment per Eligible kWh $0.26
Total PCE Eligible kWh 201,648 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.51
Average Monthly PCE Eligible kWh per
Residential Customer
341 Last Reported PCE Level (per kWh) $0.27
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,385 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
59 PCE Eligible kWh vs Total kWh Sold 61.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons) 0
Non‐Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold $0
Annual Non‐Fuel Expenses $72,106
Non‐Fuel Expense per kWh Sold $0.22
Total Expense per kWh Sold $0.22
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 127,050 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
$0
Community Facility kWh Sold 203,406 Line Loss (%) $0
Other kWh Sold (Non‐PCE) 0 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 330,456 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 330,456
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 139 of 191
Platinum PCE
Utility: PLATINUM COMMERCIAL COMPANY LLC
Reporting Period: 07/01/17..06/30/18
Community Population 48
Last Reported Month November
No. of Monthly Payments Made 3
Residential Customers 23
Community Facility Customers 3
Other Customers (Non‐PCE) 11
Fiscal Year PCE Payments $0
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 9,469 Average Annual PCE Payment per Eligible
Customer
$0
PCE Eligible kWh ‐ Community Facility
Customers
3,988 Average PCE Payment per Eligible kWh $0.00
Total PCE Eligible kWh 13,457 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.95
Average Monthly PCE Eligible kWh per
Residential Customer
137 Last Reported PCE Level (per kWh) $0.00
Average Monthly PCE Eligible kWh per
Community Facility Customer
443 Effective Residential Rate (per kWh) $0.95
Average Monthly PCE Eligible Community
Facility kWh per Person
28 PCE Eligible kWh vs Total kWh Sold 30.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 62,513 Fuel Used (Gallons) 6,028
Non‐Diesel kWh Generated 0 Fuel Cost $15,288
Purchased kWh 0 Average Price of Fuel $2.54
Total Purchased & Generated 62,513 Fuel Cost per kWh sold $0.34
Annual Non‐Fuel Expenses $28,962
Non‐Fuel Expense per kWh Sold $0.65
Total Expense per kWh Sold $0.99
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 9,469 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
71.6%
Community Facility kWh Sold 3,988 Line Loss (%) 27.1%
Other kWh Sold (Non‐PCE) 31,275 Fuel Efficiency (kWh per Gallon of Diesel)10.37
Total kWh Sold 44,732 PH Consumption as % of Generation 1.3%
Powerhouse (PH) Consumption kWh 823
Total kWh Sold & PH Consumption 45,555
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 140 of 191
Point Hope PCE
Utility: NORTH SLOPE BOROUGH
Reporting Period: 07/01/17..06/30/18
Community Population 711
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 186
Community Facility Customers 2
Other Customers (Non‐PCE) 87
Fiscal Year PCE Payments $4,615
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 500,248 Average Annual PCE Payment per Eligible
Customer
$25
PCE Eligible kWh ‐ Community Facility
Customers
53,297 Average PCE Payment per Eligible kWh $0.01
Total PCE Eligible kWh 553,545 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.18
Average Monthly PCE Eligible kWh per
Residential Customer
224 Last Reported PCE Level (per kWh) $0.00
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,221 Effective Residential Rate (per kWh) $0.18
Average Monthly PCE Eligible Community
Facility kWh per Person
6 PCE Eligible kWh vs Total kWh Sold 9.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 6,802,322 Fuel Used (Gallons) 545,613
Non‐Diesel kWh Generated 0 Fuel Cost $1,437,409
Purchased kWh 0 Average Price of Fuel $2.63
Total Purchased & Generated 6,802,322 Fuel Cost per kWh sold $0.25
Annual Non‐Fuel Expenses $1,305,437
Non‐Fuel Expense per kWh Sold $0.23
Total Expense per kWh Sold $0.48
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,660,503 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
83.9%
Community Facility kWh Sold 53,297 Line Loss (%) 12.2%
Other kWh Sold (Non‐PCE) 3,990,761 Fuel Efficiency (kWh per Gallon of Diesel)12.47
Total kWh Sold 5,704,561 PH Consumption as % of Generation 3.9%
Powerhouse (PH) Consumption kWh 268,225
Total kWh Sold & PH Consumption 5,972,786
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 141 of 191
Point Lay PCE
Utility: NORTH SLOPE BOROUGH
Reporting Period: 07/01/17..06/30/18
Community Population 269
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 64
Community Facility Customers 1
Other Customers (Non‐PCE) 44
Fiscal Year PCE Payments $1,476
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 128,704 Average Annual PCE Payment per Eligible
Customer
$23
PCE Eligible kWh ‐ Community Facility
Customers
19,158 Average PCE Payment per Eligible kWh $0.01
Total PCE Eligible kWh 147,862 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.19
Average Monthly PCE Eligible kWh per
Residential Customer
168 Last Reported PCE Level (per kWh) $0.00
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,597 Effective Residential Rate (per kWh) $0.19
Average Monthly PCE Eligible Community
Facility kWh per Person
6 PCE Eligible kWh vs Total kWh Sold 5.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 3,535,715 Fuel Used (Gallons) 262,256
Non‐Diesel kWh Generated 0 Fuel Cost $677,676
Purchased kWh 0 Average Price of Fuel $2.58
Total Purchased & Generated 3,535,715 Fuel Cost per kWh sold $0.23
Annual Non‐Fuel Expenses $1,033,664
Non‐Fuel Expense per kWh Sold $0.35
Total Expense per kWh Sold $0.58
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 608,659 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
84.1%
Community Facility kWh Sold 19,158 Line Loss (%) 15.3%
Other kWh Sold (Non‐PCE) 2,345,392 Fuel Efficiency (kWh per Gallon of Diesel)13.48
Total kWh Sold 2,973,209 PH Consumption as % of Generation 0.6%
Powerhouse (PH) Consumption kWh 22,883
Total kWh Sold & PH Consumption 2,996,092
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 142 of 191
Port Alsworth PCE
Utility: TANALIAN ELECTRIC COOPERATIVE
Reporting Period: 07/01/17..06/30/18
Community Population 218
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 84
Community Facility Customers 0
Other Customers (Non‐PCE) 68
Fiscal Year PCE Payments $81,685
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 259,719 Average Annual PCE Payment per Eligible
Customer
$972
PCE Eligible kWh ‐ Community Facility
Customers
0 Average PCE Payment per Eligible kWh $0.31
Total PCE Eligible kWh 259,719 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.56
Average Monthly PCE Eligible kWh per
Residential Customer
258 Last Reported PCE Level (per kWh) $0.32
Average Monthly PCE Eligible kWh per
Community Facility Customer
0 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
0 PCE Eligible kWh vs Total kWh Sold 30.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 936,769 Fuel Used (Gallons) 77,167
Non‐Diesel kWh Generated 0 Fuel Cost $269,416
Purchased kWh 0 Average Price of Fuel $3.49
Total Purchased & Generated 936,769 Fuel Cost per kWh sold $0.31
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.31
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 313,460 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
92.5%
Community Facility kWh Sold 16,500 Line Loss (%) 5.1%
Other kWh Sold (Non‐PCE) 536,487 Fuel Efficiency (kWh per Gallon of Diesel)12.14
Total kWh Sold 866,447 PH Consumption as % of Generation 2.4%
Powerhouse (PH) Consumption kWh 22,670
Total kWh Sold & PH Consumption 889,117
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 143 of 191
Port Heiden PCE
Utility: PORT HEIDEN UTILITIES
Reporting Period: 07/01/17..06/30/18
Community Population 98
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 47
Community Facility Customers 6
Other Customers (Non‐PCE) 31
Fiscal Year PCE Payments $65,222
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 156,140 Average Annual PCE Payment per Eligible
Customer
$1,231
PCE Eligible kWh ‐ Community Facility
Customers
51,079 Average PCE Payment per Eligible kWh $0.31
Total PCE Eligible kWh 207,219 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.65
Average Monthly PCE Eligible kWh per
Residential Customer
277 Last Reported PCE Level (per kWh) $0.30
Average Monthly PCE Eligible kWh per
Community Facility Customer
709 Effective Residential Rate (per kWh) $0.35
Average Monthly PCE Eligible Community
Facility kWh per Person
43 PCE Eligible kWh vs Total kWh Sold 41.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 594,720 Fuel Used (Gallons) 51,523
Non‐Diesel kWh Generated 0 Fuel Cost $123,603
Purchased kWh 0 Average Price of Fuel $2.40
Total Purchased & Generated 594,720 Fuel Cost per kWh sold $0.25
Annual Non‐Fuel Expenses $54,498
Non‐Fuel Expense per kWh Sold $0.11
Total Expense per kWh Sold $0.35
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 202,587 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
84.8%
Community Facility kWh Sold 56,316 Line Loss (%) 9.6%
Other kWh Sold (Non‐PCE) 245,357 Fuel Efficiency (kWh per Gallon of Diesel)11.54
Total kWh Sold 504,260 PH Consumption as % of Generation 5.7%
Powerhouse (PH) Consumption kWh 33,637
Total kWh Sold & PH Consumption 537,897
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 144 of 191
Quinhagak PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 735
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 186
Community Facility Customers 17
Other Customers (Non‐PCE) 25
Fiscal Year PCE Payments $265,129
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 807,039 Average Annual PCE Payment per Eligible
Customer
$1,306
PCE Eligible kWh ‐ Community Facility
Customers
287,911 Average PCE Payment per Eligible kWh $0.24
Total PCE Eligible kWh 1,094,950 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.49
Average Monthly PCE Eligible kWh per
Residential Customer
362 Last Reported PCE Level (per kWh) $0.23
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,411 Effective Residential Rate (per kWh) $0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
33 PCE Eligible kWh vs Total kWh Sold 54.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,595,188 Fuel Used (Gallons) 123,189
Non‐Diesel kWh Generated 567,230 Fuel Cost $325,613
Purchased kWh 0 Average Price of Fuel $2.66
Total Purchased & Generated 2,162,418 Fuel Cost per kWh sold $0.16
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.16
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 970,214 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
93.0%
Community Facility kWh Sold 384,879 Line Loss (%) 5.3%
Other kWh Sold (Non‐PCE) 656,590 Fuel Efficiency (kWh per Gallon of Diesel)12.95
Total kWh Sold 2,011,683 PH Consumption as % of Generation 1.7%
Powerhouse (PH) Consumption kWh 36,153
Total kWh Sold & PH Consumption 2,047,836
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 145 of 191
Rampart PCE
Utility: RAMPART VILLAGE COUNCIL
Reporting Period: 07/01/17..06/30/18
Community Population 64
Last Reported Month May
No. of Monthly Payments Made 9
Residential Customers 34
Community Facility Customers 8
Other Customers (Non‐PCE) 6
Fiscal Year PCE Payments $39,555
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 42,705 Average Annual PCE Payment per Eligible
Customer
$942
PCE Eligible kWh ‐ Community Facility
Customers
40,006 Average PCE Payment per Eligible kWh $0.48
Total PCE Eligible kWh 82,711 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.91
Average Monthly PCE Eligible kWh per
Residential Customer
140 Last Reported PCE Level (per kWh) $0.53
Average Monthly PCE Eligible kWh per
Community Facility Customer
556 Effective Residential Rate (per kWh) $0.38
Average Monthly PCE Eligible Community
Facility kWh per Person
69 PCE Eligible kWh vs Total kWh Sold 63.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 162,335 Fuel Used (Gallons) 14,539
Non‐Diesel kWh Generated 0 Fuel Cost $44,721
Purchased kWh 0 Average Price of Fuel $3.08
Total Purchased & Generated 162,335 Fuel Cost per kWh sold $0.35
Annual Non‐Fuel Expenses $15,382
Non‐Fuel Expense per kWh Sold $0.12
Total Expense per kWh Sold $0.46
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 45,073 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
79.8%
Community Facility kWh Sold 60,715 Line Loss (%) 7.7%
Other kWh Sold (Non‐PCE) 23,703 Fuel Efficiency (kWh per Gallon of Diesel)11.17
Total kWh Sold 129,491 PH Consumption as % of Generation 12.5%
Powerhouse (PH) Consumption kWh 20,281
Total kWh Sold & PH Consumption 149,772
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 146 of 191
Red Devil PCE
Utility: MIDDLE KUSKOKWIM ELECTRIC COOPERATIVE INC
Reporting Period: 07/01/17..06/30/18
Community Population 15
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 13
Community Facility Customers 0
Other Customers (Non‐PCE) 5
Fiscal Year PCE Payments $21,175
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 29,935 Average Annual PCE Payment per Eligible
Customer
$1,629
PCE Eligible kWh ‐ Community Facility
Customers
0 Average PCE Payment per Eligible kWh $0.71
Total PCE Eligible kWh 29,935 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.18
Average Monthly PCE Eligible kWh per
Residential Customer
192 Last Reported PCE Level (per kWh) $0.74
Average Monthly PCE Eligible kWh per
Community Facility Customer
0 Effective Residential Rate (per kWh) $0.44
Average Monthly PCE Eligible Community
Facility kWh per Person
0 PCE Eligible kWh vs Total kWh Sold 53.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 66,398 Fuel Used (Gallons) 9,007
Non‐Diesel kWh Generated 0 Fuel Cost $25,752
Purchased kWh 0 Average Price of Fuel $2.86
Total Purchased & Generated 66,398 Fuel Cost per kWh sold $0.46
Annual Non‐Fuel Expenses $119,058
Non‐Fuel Expense per kWh Sold $2.12
Total Expense per kWh Sold $2.58
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 33,704 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
84.6%
Community Facility kWh Sold 591 Line Loss (%) 14.6%
Other kWh Sold (Non‐PCE) 21,884 Fuel Efficiency (kWh per Gallon of Diesel)7.37
Total kWh Sold 56,179 PH Consumption as % of Generation 0.8%
Powerhouse (PH) Consumption kWh 539
Total kWh Sold & PH Consumption 56,718
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 147 of 191
Ruby PCE
Utility: CITY OF RUBY
Reporting Period: 07/01/17..06/30/18
Community Population 178
Last Reported Month May
No. of Monthly Payments Made 11
Residential Customers 110
Community Facility Customers 33
Other Customers (Non‐PCE) 19
Fiscal Year PCE Payments $103,272
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 201,254 Average Annual PCE Payment per Eligible
Customer
$722
PCE Eligible kWh ‐ Community Facility
Customers
79,247 Average PCE Payment per Eligible kWh $0.37
Total PCE Eligible kWh 280,501 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.75
Average Monthly PCE Eligible kWh per
Residential Customer
166 Last Reported PCE Level (per kWh) $0.42
Average Monthly PCE Eligible kWh per
Community Facility Customer
218 Effective Residential Rate (per kWh) $0.33
Average Monthly PCE Eligible Community
Facility kWh per Person
40 PCE Eligible kWh vs Total kWh Sold 47.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 603,675 Fuel Used (Gallons) 49,247
Non‐Diesel kWh Generated 0 Fuel Cost $203,217
Purchased kWh 0 Average Price of Fuel $4.13
Total Purchased & Generated 603,675 Fuel Cost per kWh sold $0.34
Annual Non‐Fuel Expenses $237,217
Non‐Fuel Expense per kWh Sold $0.40
Total Expense per kWh Sold $0.74
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 214,340 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
98.8%
Community Facility kWh Sold 80,604 Line Loss (%) $0
Other kWh Sold (Non‐PCE) 301,575 Fuel Efficiency (kWh per Gallon of Diesel)12.26
Total kWh Sold 596,519 PH Consumption as % of Generation 3.8%
Powerhouse (PH) Consumption kWh 22,815
Total kWh Sold & PH Consumption 619,334
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 148 of 191
Russian Mission PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 331
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 76
Community Facility Customers 6
Other Customers (Non‐PCE) 15
Fiscal Year PCE Payments $114,609
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 347,045 Average Annual PCE Payment per Eligible
Customer
$1,398
PCE Eligible kWh ‐ Community Facility
Customers
63,458 Average PCE Payment per Eligible kWh $0.28
Total PCE Eligible kWh 410,503 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.52
Average Monthly PCE Eligible kWh per
Residential Customer
381 Last Reported PCE Level (per kWh) $0.28
Average Monthly PCE Eligible kWh per
Community Facility Customer
881 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
16 PCE Eligible kWh vs Total kWh Sold 44.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 996,554 Fuel Used (Gallons) 70,561
Non‐Diesel kWh Generated 0 Fuel Cost $180,922
Purchased kWh 0 Average Price of Fuel $2.51
Total Purchased & Generated 996,554 Fuel Cost per kWh sold $0.20
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.20
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 411,708 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
92.8%
Community Facility kWh Sold 100,972 Line Loss (%) 5.0%
Other kWh Sold (Non‐PCE) 411,852 Fuel Efficiency (kWh per Gallon of Diesel)14.12
Total kWh Sold 924,532 PH Consumption as % of Generation 2.3%
Powerhouse (PH) Consumption kWh 22,656
Total kWh Sold & PH Consumption 947,188
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 149 of 191
Sand Point PCE
Utility: TDX CORPORATION
Reporting Period: 07/01/17..06/30/18
Community Population 943
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 280
Community Facility Customers 27
Other Customers (Non‐PCE) 88
Fiscal Year PCE Payments $420,267
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 977,861 Average Annual PCE Payment per Eligible
Customer
$1,369
PCE Eligible kWh ‐ Community Facility
Customers
752,785 Average PCE Payment per Eligible kWh $0.24
Total PCE Eligible kWh 1,730,646 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.76
Average Monthly PCE Eligible kWh per
Residential Customer
291 Last Reported PCE Level (per kWh) $0.25
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,323 Effective Residential Rate (per kWh) $0.51
Average Monthly PCE Eligible Community
Facility kWh per Person
67 PCE Eligible kWh vs Total kWh Sold 48.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 3,191,334 Fuel Used (Gallons) 233,961
Non‐Diesel kWh Generated 0 Fuel Cost $642,091
Purchased kWh 730,979 Average Price of Fuel $2.74
Total Purchased & Generated 3,922,313 Fuel Cost per kWh sold $0.18
Annual Non‐Fuel Expenses $1,317,693
Non‐Fuel Expense per kWh Sold $0.37
Total Expense per kWh Sold $0.55
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,268,539 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
91.3%
Community Facility kWh Sold 837,529 Line Loss (%) 6.0%
Other kWh Sold (Non‐PCE) 1,474,722 Fuel Efficiency (kWh per Gallon of Diesel)13.64
Total kWh Sold 3,580,790 PH Consumption as % of Generation 2.7%
Powerhouse (PH) Consumption kWh 104,480
Total kWh Sold & PH Consumption 3,685,270
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 150 of 191
Savoonga PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 729
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 158
Community Facility Customers 9
Other Customers (Non‐PCE) 46
Fiscal Year PCE Payments $230,646
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 706,686 Average Annual PCE Payment per Eligible
Customer
$1,381
PCE Eligible kWh ‐ Community Facility
Customers
196,900 Average PCE Payment per Eligible kWh $0.26
Total PCE Eligible kWh 903,586 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.50
Average Monthly PCE Eligible kWh per
Residential Customer
373 Last Reported PCE Level (per kWh) $0.25
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,823 Effective Residential Rate (per kWh) $0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
23 PCE Eligible kWh vs Total kWh Sold 41.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,148,940 Fuel Used (Gallons) 151,229
Non‐Diesel kWh Generated 125,256 Fuel Cost $398,020
Purchased kWh 0 Average Price of Fuel $2.63
Total Purchased & Generated 2,274,196 Fuel Cost per kWh sold $0.18
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.18
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 909,002 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
95.6%
Community Facility kWh Sold 609,210 Line Loss (%) 3.0%
Other kWh Sold (Non‐PCE) 655,535 Fuel Efficiency (kWh per Gallon of Diesel)14.21
Total kWh Sold 2,173,747 PH Consumption as % of Generation 1.4%
Powerhouse (PH) Consumption kWh 31,491
Total kWh Sold & PH Consumption 2,205,238
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 151 of 191
Scammon Bay PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 570
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 122
Community Facility Customers 8
Other Customers (Non‐PCE) 35
Fiscal Year PCE Payments $176,224
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 524,468 Average Annual PCE Payment per Eligible
Customer
$1,356
PCE Eligible kWh ‐ Community Facility
Customers
129,206 Average PCE Payment per Eligible kWh $0.27
Total PCE Eligible kWh 653,674 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.51
Average Monthly PCE Eligible kWh per
Residential Customer
358 Last Reported PCE Level (per kWh) $0.27
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,346 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
19 PCE Eligible kWh vs Total kWh Sold 42.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,647,222 Fuel Used (Gallons) 116,936
Non‐Diesel kWh Generated 0 Fuel Cost $306,726
Purchased kWh 0 Average Price of Fuel $2.61
Total Purchased & Generated 1,647,222 Fuel Cost per kWh sold $0.20
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.20
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 608,655 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
93.7%
Community Facility kWh Sold 249,100 Line Loss (%) 4.3%
Other kWh Sold (Non‐PCE) 686,146 Fuel Efficiency (kWh per Gallon of Diesel)14.09
Total kWh Sold 1,543,901 PH Consumption as % of Generation 2.0%
Powerhouse (PH) Consumption kWh 33,062
Total kWh Sold & PH Consumption 1,576,963
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 152 of 191
Selawik PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 847
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 165
Community Facility Customers 17
Other Customers (Non‐PCE) 39
Fiscal Year PCE Payments $339,060
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 744,697 Average Annual PCE Payment per Eligible
Customer
$1,863
PCE Eligible kWh ‐ Community Facility
Customers
533,606 Average PCE Payment per Eligible kWh $0.27
Total PCE Eligible kWh 1,278,303 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.52
Average Monthly PCE Eligible kWh per
Residential Customer
376 Last Reported PCE Level (per kWh) $0.28
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,616 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
52 PCE Eligible kWh vs Total kWh Sold 51.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,691,929 Fuel Used (Gallons) 195,505
Non‐Diesel kWh Generated 11,762 Fuel Cost $565,445
Purchased kWh 0 Average Price of Fuel $2.92
Total Purchased & Generated 2,703,691 Fuel Cost per kWh sold $0.23
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.23
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,016,259 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
92.7%
Community Facility kWh Sold 698,596 Line Loss (%) 5.5%
Other kWh Sold (Non‐PCE) 792,332 Fuel Efficiency (kWh per Gallon of Diesel)13.77
Total kWh Sold 2,507,187 PH Consumption as % of Generation 1.8%
Powerhouse (PH) Consumption kWh 47,905
Total kWh Sold & PH Consumption 2,555,092
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 153 of 191
Shageluk PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 77
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 36
Community Facility Customers 8
Other Customers (Non‐PCE) 12
Fiscal Year PCE Payments $45,970
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 104,474 Average Annual PCE Payment per Eligible
Customer
$1,045
PCE Eligible kWh ‐ Community Facility
Customers
43,115 Average PCE Payment per Eligible kWh $0.31
Total PCE Eligible kWh 147,589 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.54
Average Monthly PCE Eligible kWh per
Residential Customer
242 Last Reported PCE Level (per kWh) $0.30
Average Monthly PCE Eligible kWh per
Community Facility Customer
449 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
47 PCE Eligible kWh vs Total kWh Sold 39.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 413,027 Fuel Used (Gallons) 34,663
Non‐Diesel kWh Generated 0 Fuel Cost $85,972
Purchased kWh 0 Average Price of Fuel $2.51
Total Purchased & Generated 413,027 Fuel Cost per kWh sold $0.23
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.23
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 124,659 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
90.9%
Community Facility kWh Sold 65,718 Line Loss (%) 5.7%
Other kWh Sold (Non‐PCE) 184,952 Fuel Efficiency (kWh per Gallon of Diesel)11.92
Total kWh Sold 375,329 PH Consumption as % of Generation 3.4%
Powerhouse (PH) Consumption kWh 13,975
Total kWh Sold & PH Consumption 389,304
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 154 of 191
Shaktoolik PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 281
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 62
Community Facility Customers 4
Other Customers (Non‐PCE) 28
Fiscal Year PCE Payments $90,736
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 312,460 Average Annual PCE Payment per Eligible
Customer
$1,375
PCE Eligible kWh ‐ Community Facility
Customers
65,907 Average PCE Payment per Eligible kWh $0.24
Total PCE Eligible kWh 378,367 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.50
Average Monthly PCE Eligible kWh per
Residential Customer
420 Last Reported PCE Level (per kWh) $0.23
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,373 Effective Residential Rate (per kWh) $0.27
Average Monthly PCE Eligible Community
Facility kWh per Person
20 PCE Eligible kWh vs Total kWh Sold 37.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 778,175 Fuel Used (Gallons) 60,886
Non‐Diesel kWh Generated 346,958 Fuel Cost $162,030
Purchased kWh 0 Average Price of Fuel $2.67
Total Purchased & Generated 1,125,133 Fuel Cost per kWh sold $0.16
Annual Non‐Fuel Expenses $219,541
Non‐Fuel Expense per kWh Sold $0.22
Total Expense per kWh Sold $0.38
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 423,331 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
89.4%
Community Facility kWh Sold 133,134 Line Loss (%) 3.7%
Other kWh Sold (Non‐PCE) 449,676 Fuel Efficiency (kWh per Gallon of Diesel)12.78
Total kWh Sold 1,006,141 PH Consumption as % of Generation 6.9%
Powerhouse (PH) Consumption kWh 77,910
Total kWh Sold & PH Consumption 1,084,051
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 155 of 191
Shishmaref PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 597
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 145
Community Facility Customers 10
Other Customers (Non‐PCE) 48
Fiscal Year PCE Payments $207,627
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 617,615 Average Annual PCE Payment per Eligible
Customer
$1,340
PCE Eligible kWh ‐ Community Facility
Customers
118,106 Average PCE Payment per Eligible kWh $0.28
Total PCE Eligible kWh 735,721 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.53
Average Monthly PCE Eligible kWh per
Residential Customer
355 Last Reported PCE Level (per kWh) $0.28
Average Monthly PCE Eligible kWh per
Community Facility Customer
984 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
16 PCE Eligible kWh vs Total kWh Sold 46.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,653,881 Fuel Used (Gallons) 129,275
Non‐Diesel kWh Generated 0 Fuel Cost $369,130
Purchased kWh 0 Average Price of Fuel $2.82
Total Purchased & Generated 1,653,881 Fuel Cost per kWh sold $0.23
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.23
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 706,014 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
96.7%
Community Facility kWh Sold 222,892 Line Loss (%) 0.1%
Other kWh Sold (Non‐PCE) 670,027 Fuel Efficiency (kWh per Gallon of Diesel)12.79
Total kWh Sold 1,598,933 PH Consumption as % of Generation 3.2%
Powerhouse (PH) Consumption kWh 53,325
Total kWh Sold & PH Consumption 1,652,258
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 156 of 191
Shungnak PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 299
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 62
Community Facility Customers 9
Other Customers (Non‐PCE) 19
Fiscal Year PCE Payments $153,579
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 288,610 Average Annual PCE Payment per Eligible
Customer
$2,163
PCE Eligible kWh ‐ Community Facility
Customers
149,596 Average PCE Payment per Eligible kWh $0.35
Total PCE Eligible kWh 438,206 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.67
Average Monthly PCE Eligible kWh per
Residential Customer
388 Last Reported PCE Level (per kWh) $0.42
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,385 Effective Residential Rate (per kWh) $0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
42 PCE Eligible kWh vs Total kWh Sold 48.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,626,999 Fuel Used (Gallons) 118,477
Non‐Diesel kWh Generated 0 Fuel Cost $471,246
Purchased kWh 0 Average Price of Fuel $3.96
Total Purchased & Generated 1,626,999 Fuel Cost per kWh sold $0.52
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.52
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 378,934 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
55.7%
Community Facility kWh Sold 198,890 Line Loss (%) 41.5%
Other kWh Sold (Non‐PCE) 328,322 Fuel Efficiency (kWh per Gallon of Diesel)13.73
Total kWh Sold 906,146 PH Consumption as % of Generation 2.8%
Powerhouse (PH) Consumption kWh 45,922
Total kWh Sold & PH Consumption 952,068
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 157 of 191
Skagway PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 1065
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 673
Community Facility Customers 44
Other Customers (Non‐PCE) 550
Fiscal Year PCE Payments $87,682
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 2,006,620 Average Annual PCE Payment per Eligible
Customer
$122
PCE Eligible kWh ‐ Community Facility
Customers
848,289 Average PCE Payment per Eligible kWh $0.03
Total PCE Eligible kWh 2,854,909 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.28
Average Monthly PCE Eligible kWh per
Residential Customer
248 Last Reported PCE Level (per kWh) $0.04
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,607 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
66 PCE Eligible kWh vs Total kWh Sold 21.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 55,947 Fuel Used (Gallons) 4,746
Non‐Diesel kWh Generated 1,968,782 Fuel Cost $12,099
Purchased kWh 12,527,992 Average Price of Fuel $2.55
Total Purchased & Generated 14,552,721 Fuel Cost per kWh sold $0.00
Annual Non‐Fuel Expenses $1,882,120
Non‐Fuel Expense per kWh Sold $0.14
Total Expense per kWh Sold $0.14
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 3,427,578 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
91.3%
Community Facility kWh Sold 1,117,475 Line Loss (%) 7.9%
Other kWh Sold (Non‐PCE) 8,748,446 Fuel Efficiency (kWh per Gallon of Diesel)11.79
Total kWh Sold 13,293,499 PH Consumption as % of Generation 0.7%
Powerhouse (PH) Consumption kWh 106,229
Total kWh Sold & PH Consumption 13,399,728
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 158 of 191
Slana PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 128
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 82
Community Facility Customers 1
Other Customers (Non‐PCE) 17
Fiscal Year PCE Payments $71,764
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 236,320 Average Annual PCE Payment per Eligible
Customer
$865
PCE Eligible kWh ‐ Community Facility
Customers
2,168 Average PCE Payment per Eligible kWh $0.30
Total PCE Eligible kWh 238,488 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.66
Average Monthly PCE Eligible kWh per
Residential Customer
240 Last Reported PCE Level (per kWh) $0.36
Average Monthly PCE Eligible kWh per
Community Facility Customer
181 Effective Residential Rate (per kWh) $0.30
Average Monthly PCE Eligible Community
Facility kWh per Person
1 PCE Eligible kWh vs Total kWh Sold 46.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,393,272 Fuel Used (Gallons) 93,775
Non‐Diesel kWh Generated 0 Fuel Cost $218,388
Purchased kWh 0 Average Price of Fuel $2.33
Total Purchased & Generated 1,393,272 Fuel Cost per kWh sold $0.42
Annual Non‐Fuel Expenses $397,360
Non‐Fuel Expense per kWh Sold $0.77
Total Expense per kWh Sold $1.19
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 339,906 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
37.1%
Community Facility kWh Sold 2,168 Line Loss (%) 61.9%
Other kWh Sold (Non‐PCE) 175,196 Fuel Efficiency (kWh per Gallon of Diesel)14.86
Total kWh Sold 517,270 PH Consumption as % of Generation 1.0%
Powerhouse (PH) Consumption kWh 13,836
Total kWh Sold & PH Consumption 531,106
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 159 of 191
Sleetmute PCE
Utility: MIDDLE KUSKOKWIM ELECTRIC COOPERATIVE INC
Reporting Period: 07/01/17..06/30/18
Community Population 98
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 34
Community Facility Customers 4
Other Customers (Non‐PCE) 10
Fiscal Year PCE Payments $81,516
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 71,311 Average Annual PCE Payment per Eligible
Customer
$2,145
PCE Eligible kWh ‐ Community Facility
Customers
43,628 Average PCE Payment per Eligible kWh $0.71
Total PCE Eligible kWh 114,939 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.18
Average Monthly PCE Eligible kWh per
Residential Customer
175 Last Reported PCE Level (per kWh) $0.74
Average Monthly PCE Eligible kWh per
Community Facility Customer
909 Effective Residential Rate (per kWh) $0.44
Average Monthly PCE Eligible Community
Facility kWh per Person
37 PCE Eligible kWh vs Total kWh Sold 52.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 253,767 Fuel Used (Gallons) 24,166
Non‐Diesel kWh Generated 0 Fuel Cost $69,115
Purchased kWh 0 Average Price of Fuel $2.86
Total Purchased & Generated 253,767 Fuel Cost per kWh sold $0.31
Annual Non‐Fuel Expenses $237,683
Non‐Fuel Expense per kWh Sold $1.08
Total Expense per kWh Sold $1.39
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 82,105 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
87.0%
Community Facility kWh Sold 49,528 Line Loss (%) 7.2%
Other kWh Sold (Non‐PCE) 89,090 Fuel Efficiency (kWh per Gallon of Diesel)10.50
Total kWh Sold 220,723 PH Consumption as % of Generation 5.8%
Powerhouse (PH) Consumption kWh 14,840
Total kWh Sold & PH Consumption 235,563
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 160 of 191
St. George PCE
Utility: CITY OF ST. GEORGE
Reporting Period: 07/01/17..06/30/18
Community Population 72
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 39
Community Facility Customers 7
Other Customers (Non‐PCE) 28
Fiscal Year PCE Payments $123,163
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 100,359 Average Annual PCE Payment per Eligible
Customer
$2,677
PCE Eligible kWh ‐ Community Facility
Customers
58,980 Average PCE Payment per Eligible kWh $0.77
Total PCE Eligible kWh 159,339 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.00
Average Monthly PCE Eligible kWh per
Residential Customer
214 Last Reported PCE Level (per kWh) $0.78
Average Monthly PCE Eligible kWh per
Community Facility Customer
702 Effective Residential Rate (per kWh) $0.22
Average Monthly PCE Eligible Community
Facility kWh per Person
68 PCE Eligible kWh vs Total kWh Sold 34.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 592,285 Fuel Used (Gallons) 50,266
Non‐Diesel kWh Generated 0 Fuel Cost $346,480
Purchased kWh 0 Average Price of Fuel $6.89
Total Purchased & Generated 592,285 Fuel Cost per kWh sold $0.76
Annual Non‐Fuel Expenses $20,490
Non‐Fuel Expense per kWh Sold $0.04
Total Expense per kWh Sold $0.80
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 140,533 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
77.3%
Community Facility kWh Sold 87,609 Line Loss (%) 15.9%
Other kWh Sold (Non‐PCE) 229,804 Fuel Efficiency (kWh per Gallon of Diesel)11.78
Total kWh Sold 457,946 PH Consumption as % of Generation 6.8%
Powerhouse (PH) Consumption kWh 40,107
Total kWh Sold & PH Consumption 498,053
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 161 of 191
St. Mary's; Andreafsky PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 587
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 172
Community Facility Customers 18
Other Customers (Non‐PCE) 61
Fiscal Year PCE Payments $285,684
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 661,850 Average Annual PCE Payment per Eligible
Customer
$1,504
PCE Eligible kWh ‐ Community Facility
Customers
431,993 Average PCE Payment per Eligible kWh $0.26
Total PCE Eligible kWh 1,093,843 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.51
Average Monthly PCE Eligible kWh per
Residential Customer
321 Last Reported PCE Level (per kWh) $0.27
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,000 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
61 PCE Eligible kWh vs Total kWh Sold 42.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 3,079,112 Fuel Used (Gallons) 227,888
Non‐Diesel kWh Generated 0 Fuel Cost $567,120
Purchased kWh 0 Average Price of Fuel $2.44
Total Purchased & Generated 3,079,112 Fuel Cost per kWh sold $0.22
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.22
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 781,452 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
84.4%
Community Facility kWh Sold 645,601 Line Loss (%) 14.2%
Other kWh Sold (Non‐PCE) 1,170,718 Fuel Efficiency (kWh per Gallon of Diesel)13.51
Total kWh Sold 2,597,771 PH Consumption as % of Generation 1.5%
Powerhouse (PH) Consumption kWh 44,748
Total kWh Sold & PH Consumption 2,642,519
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 162 of 191
St. Michael PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 417
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 92
Community Facility Customers 10
Other Customers (Non‐PCE) 40
Fiscal Year PCE Payments $178,847
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 422,597 Average Annual PCE Payment per Eligible
Customer
$1,753
PCE Eligible kWh ‐ Community Facility
Customers
299,391 Average PCE Payment per Eligible kWh $0.25
Total PCE Eligible kWh 721,988 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.50
Average Monthly PCE Eligible kWh per
Residential Customer
383 Last Reported PCE Level (per kWh) $0.26
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,495 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
60 PCE Eligible kWh vs Total kWh Sold 40.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons) 0
Non‐Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold $0
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.00
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 573,395 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
$0
Community Facility kWh Sold 533,177 Line Loss (%) $0
Other kWh Sold (Non‐PCE) 691,801 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 1,798,373 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 1,798,373
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 163 of 191
St. Paul PCE
Utility: ST. PAUL MUNICIPAL ELECTRIC
Reporting Period: 07/01/17..06/30/18
Community Population 397
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 152
Community Facility Customers 31
Other Customers (Non‐PCE) 50
Fiscal Year PCE Payments $249,681
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 602,251 Average Annual PCE Payment per Eligible
Customer
$1,364
PCE Eligible kWh ‐ Community Facility
Customers
333,480 Average PCE Payment per Eligible kWh $0.27
Total PCE Eligible kWh 935,731 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.41
Average Monthly PCE Eligible kWh per
Residential Customer
330 Last Reported PCE Level (per kWh) $0.23
Average Monthly PCE Eligible kWh per
Community Facility Customer
896 Effective Residential Rate (per kWh) $0.18
Average Monthly PCE Eligible Community
Facility kWh per Person
70 PCE Eligible kWh vs Total kWh Sold 31.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 3,033,386 Fuel Used (Gallons) 50,266
Non‐Diesel kWh Generated 0 Fuel Cost $811,531
Purchased kWh 418,343 Average Price of Fuel $16.14
Total Purchased & Generated 3,451,729 Fuel Cost per kWh sold $0.27
Annual Non‐Fuel Expenses $608,949
Non‐Fuel Expense per kWh Sold $0.20
Total Expense per kWh Sold $0.48
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 676,596 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
86.4%
Community Facility kWh Sold 453,820 Line Loss (%) 8.4%
Other kWh Sold (Non‐PCE) 1,851,734 Fuel Efficiency (kWh per Gallon of Diesel)60.35
Total kWh Sold 2,982,150 PH Consumption as % of Generation 5.2%
Powerhouse (PH) Consumption kWh 179,326
Total kWh Sold & PH Consumption 3,161,476
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 164 of 191
Stebbins PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 630
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 135
Community Facility Customers 12
Other Customers (Non‐PCE) 36
Fiscal Year PCE Payments $178,281
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 571,561 Average Annual PCE Payment per Eligible
Customer
$1,213
PCE Eligible kWh ‐ Community Facility
Customers
102,475 Average PCE Payment per Eligible kWh $0.26
Total PCE Eligible kWh 674,036 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.50
Average Monthly PCE Eligible kWh per
Residential Customer
353 Last Reported PCE Level (per kWh) $0.26
Average Monthly PCE Eligible kWh per
Community Facility Customer
712 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
14 PCE Eligible kWh vs Total kWh Sold 42.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 3,553,170 Fuel Used (Gallons) 248,099
Non‐Diesel kWh Generated 0 Fuel Cost $653,461
Purchased kWh 0 Average Price of Fuel $2.63
Total Purchased & Generated 3,553,170 Fuel Cost per kWh sold $0.42
Annual Non‐Fuel Expenses $342,453
Non‐Fuel Expense per kWh Sold $0.22
Total Expense per kWh Sold $0.63
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 710,667 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
44.2%
Community Facility kWh Sold 224,447 Line Loss (%) 54.3%
Other kWh Sold (Non‐PCE) 634,319 Fuel Efficiency (kWh per Gallon of Diesel)14.32
Total kWh Sold 1,569,433 PH Consumption as % of Generation 1.5%
Powerhouse (PH) Consumption kWh 52,724
Total kWh Sold & PH Consumption 1,622,157
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 165 of 191
Stevens Village PCE
Utility: STEVENS VILLAGE IRA COUNCIL
Reporting Period: 07/01/17..06/30/18
Community Population 41
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 13
Community Facility Customers 3
Other Customers (Non‐PCE) 6
Fiscal Year PCE Payments $25,732
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 22,542 Average Annual PCE Payment per Eligible
Customer
$1,608
PCE Eligible kWh ‐ Community Facility
Customers
24,970 Average PCE Payment per Eligible kWh $0.54
Total PCE Eligible kWh 47,512 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.07
Average Monthly PCE Eligible kWh per
Residential Customer
145 Last Reported PCE Level (per kWh) $0.56
Average Monthly PCE Eligible kWh per
Community Facility Customer
694 Effective Residential Rate (per kWh) $0.51
Average Monthly PCE Eligible Community
Facility kWh per Person
51 PCE Eligible kWh vs Total kWh Sold 40.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 170,133 Fuel Used (Gallons) 20,448
Non‐Diesel kWh Generated 0 Fuel Cost $65,437
Purchased kWh 0 Average Price of Fuel $3.20
Total Purchased & Generated 170,133 Fuel Cost per kWh sold $0.55
Annual Non‐Fuel Expenses $72,826
Non‐Fuel Expense per kWh Sold $0.62
Total Expense per kWh Sold $1.17
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 23,620 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
69.3%
Community Facility kWh Sold 37,443 Line Loss (%) 20.3%
Other kWh Sold (Non‐PCE) 56,869 Fuel Efficiency (kWh per Gallon of Diesel)8.32
Total kWh Sold 117,932 PH Consumption as % of Generation 10.3%
Powerhouse (PH) Consumption kWh 17,590
Total kWh Sold & PH Consumption 135,522
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 166 of 191
Stony River PCE
Utility: MIDDLE KUSKOKWIM ELECTRIC COOPERATIVE INC
Reporting Period: 07/01/17..06/30/18
Community Population 41
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 15
Community Facility Customers 5
Other Customers (Non‐PCE) 6
Fiscal Year PCE Payments $26,300
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 37,044 Average Annual PCE Payment per Eligible
Customer
$1,315
PCE Eligible kWh ‐ Community Facility
Customers
0 Average PCE Payment per Eligible kWh $0.71
Total PCE Eligible kWh 37,044 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.18
Average Monthly PCE Eligible kWh per
Residential Customer
206 Last Reported PCE Level (per kWh) $0.74
Average Monthly PCE Eligible kWh per
Community Facility Customer
0 Effective Residential Rate (per kWh) $0.44
Average Monthly PCE Eligible Community
Facility kWh per Person
0 PCE Eligible kWh vs Total kWh Sold 36.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 121,518 Fuel Used (Gallons) 14,701
Non‐Diesel kWh Generated 0 Fuel Cost $42,065
Purchased kWh 0 Average Price of Fuel $2.86
Total Purchased & Generated 121,518 Fuel Cost per kWh sold $0.41
Annual Non‐Fuel Expenses $138,944
Non‐Fuel Expense per kWh Sold $1.35
Total Expense per kWh Sold $1.76
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 38,167 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
84.8%
Community Facility kWh Sold 14,114 Line Loss (%) 7.4%
Other kWh Sold (Non‐PCE) 50,740 Fuel Efficiency (kWh per Gallon of Diesel)8.27
Total kWh Sold 103,021 PH Consumption as % of Generation 7.9%
Powerhouse (PH) Consumption kWh 9,565
Total kWh Sold & PH Consumption 112,586
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 167 of 191
Takotna PCE
Utility: TAKOTNA COMMUNITY ASSOC INC
Reporting Period: 07/01/17..06/30/18
Community Population 64
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 35
Community Facility Customers 5
Other Customers (Non‐PCE) 17
Fiscal Year PCE Payments $38,679
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 66,769 Average Annual PCE Payment per Eligible
Customer
$967
PCE Eligible kWh ‐ Community Facility
Customers
23,455 Average PCE Payment per Eligible kWh $0.43
Total PCE Eligible kWh 90,224 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.02
Average Monthly PCE Eligible kWh per
Residential Customer
159 Last Reported PCE Level (per kWh) $0.42
Average Monthly PCE Eligible kWh per
Community Facility Customer
391 Effective Residential Rate (per kWh) $0.61
Average Monthly PCE Eligible Community
Facility kWh per Person
31 PCE Eligible kWh vs Total kWh Sold 49.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 226,266 Fuel Used (Gallons) 23,531
Non‐Diesel kWh Generated 0 Fuel Cost $84,126
Purchased kWh 0 Average Price of Fuel $3.58
Total Purchased & Generated 226,266 Fuel Cost per kWh sold $0.46
Annual Non‐Fuel Expenses $35,595
Non‐Fuel Expense per kWh Sold $0.19
Total Expense per kWh Sold $0.65
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 79,970 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
80.9%
Community Facility kWh Sold 23,679 Line Loss (%) 19.1%
Other kWh Sold (Non‐PCE) 79,306 Fuel Efficiency (kWh per Gallon of Diesel)9.62
Total kWh Sold 182,955 PH Consumption as % of Generation 0.0%
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 182,955
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 168 of 191
Tanana PCE
Utility: TANANA POWER COMPANY INC.
Reporting Period: 07/01/17..06/30/18
Community Population 224
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 104
Community Facility Customers 7
Other Customers (Non‐PCE) 54
Fiscal Year PCE Payments $140,142
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 280,367 Average Annual PCE Payment per Eligible
Customer
$1,263
PCE Eligible kWh ‐ Community Facility
Customers
155,847 Average PCE Payment per Eligible kWh $0.32
Total PCE Eligible kWh 436,214 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.65
Average Monthly PCE Eligible kWh per
Residential Customer
225 Last Reported PCE Level (per kWh) $0.30
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,855 Effective Residential Rate (per kWh) $0.35
Average Monthly PCE Eligible Community
Facility kWh per Person
58 PCE Eligible kWh vs Total kWh Sold 35.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,347,220 Fuel Used (Gallons) 99,277
Non‐Diesel kWh Generated 0 Fuel Cost $249,631
Purchased kWh 0 Average Price of Fuel $2.51
Total Purchased & Generated 1,347,220 Fuel Cost per kWh sold $0.20
Annual Non‐Fuel Expenses $399,738
Non‐Fuel Expense per kWh Sold $0.32
Total Expense per kWh Sold $0.53
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 312,718 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
91.7%
Community Facility kWh Sold 158,403 Line Loss (%) 6.1%
Other kWh Sold (Non‐PCE) 763,849 Fuel Efficiency (kWh per Gallon of Diesel)13.57
Total kWh Sold 1,234,970 PH Consumption as % of Generation 2.2%
Powerhouse (PH) Consumption kWh 29,474
Total kWh Sold & PH Consumption 1,264,444
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 169 of 191
Tatitlek PCE
Utility: TATITLEK VILLAGE IRA COUNCIL
Reporting Period: 07/01/17..06/30/18
Community Population 90
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 40
Community Facility Customers 5
Other Customers (Non‐PCE) 20
Fiscal Year PCE Payments $87,170
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 104,138 Average Annual PCE Payment per Eligible
Customer
$1,937
PCE Eligible kWh ‐ Community Facility
Customers
50,927 Average PCE Payment per Eligible kWh $0.56
Total PCE Eligible kWh 155,065 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.92
Average Monthly PCE Eligible kWh per
Residential Customer
217 Last Reported PCE Level (per kWh) $0.59
Average Monthly PCE Eligible kWh per
Community Facility Customer
849 Effective Residential Rate (per kWh) $0.33
Average Monthly PCE Eligible Community
Facility kWh per Person
47 PCE Eligible kWh vs Total kWh Sold 49.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 407,801 Fuel Used (Gallons) 34,495
Non‐Diesel kWh Generated 0 Fuel Cost $150,703
Purchased kWh 0 Average Price of Fuel $4.37
Total Purchased & Generated 407,801 Fuel Cost per kWh sold $0.48
Annual Non‐Fuel Expenses $22,718
Non‐Fuel Expense per kWh Sold $0.07
Total Expense per kWh Sold $0.56
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 115,448 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
76.4%
Community Facility kWh Sold 57,873 Line Loss (%) 15.4%
Other kWh Sold (Non‐PCE) 138,237 Fuel Efficiency (kWh per Gallon of Diesel)11.82
Total kWh Sold 311,558 PH Consumption as % of Generation 8.2%
Powerhouse (PH) Consumption kWh 33,341
Total kWh Sold & PH Consumption 344,899
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 170 of 191
Teller PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 263
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 72
Community Facility Customers 6
Other Customers (Non‐PCE) 33
Fiscal Year PCE Payments $88,274
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 258,607 Average Annual PCE Payment per Eligible
Customer
$1,132
PCE Eligible kWh ‐ Community Facility
Customers
34,941 Average PCE Payment per Eligible kWh $0.30
Total PCE Eligible kWh 293,548 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.54
Average Monthly PCE Eligible kWh per
Residential Customer
299 Last Reported PCE Level (per kWh) $0.30
Average Monthly PCE Eligible kWh per
Community Facility Customer
485 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
11 PCE Eligible kWh vs Total kWh Sold 36.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 845,976 Fuel Used (Gallons) 58,903
Non‐Diesel kWh Generated 0 Fuel Cost $160,358
Purchased kWh 0 Average Price of Fuel $2.76
Total Purchased & Generated 845,976 Fuel Cost per kWh sold $0.20
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.20
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 292,627 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
94.4%
Community Facility kWh Sold 182,345 Line Loss (%) $0
Other kWh Sold (Non‐PCE) 323,264 Fuel Efficiency (kWh per Gallon of Diesel)14.36
Total kWh Sold 798,236 PH Consumption as % of Generation 6.7%
Powerhouse (PH) Consumption kWh 56,463
Total kWh Sold & PH Consumption 854,699
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 171 of 191
Tenakee Springs PCE
Utility: CITY OF TENAKEE SPRINGS
Reporting Period: 07/01/17..06/30/18
Community Population 140
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 126
Community Facility Customers 13
Other Customers (Non‐PCE) 25
Fiscal Year PCE Payments $79,532
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 207,566 Average Annual PCE Payment per Eligible
Customer
$572
PCE Eligible kWh ‐ Community Facility
Customers
28,302 Average PCE Payment per Eligible kWh $0.34
Total PCE Eligible kWh 235,868 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.65
Average Monthly PCE Eligible kWh per
Residential Customer
137 Last Reported PCE Level (per kWh) $0.36
Average Monthly PCE Eligible kWh per
Community Facility Customer
181 Effective Residential Rate (per kWh) $0.29
Average Monthly PCE Eligible Community
Facility kWh per Person
17 PCE Eligible kWh vs Total kWh Sold 66.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 411,061 Fuel Used (Gallons) 31,666
Non‐Diesel kWh Generated 0 Fuel Cost $104,694
Purchased kWh 0 Average Price of Fuel $3.31
Total Purchased & Generated 411,061 Fuel Cost per kWh sold $0.30
Annual Non‐Fuel Expenses $70,210
Non‐Fuel Expense per kWh Sold $0.20
Total Expense per kWh Sold $0.49
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 256,969 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
86.3%
Community Facility kWh Sold 28,302 Line Loss (%) 10.7%
Other kWh Sold (Non‐PCE) 69,354 Fuel Efficiency (kWh per Gallon of Diesel)12.98
Total kWh Sold 354,625 PH Consumption as % of Generation 3.0%
Powerhouse (PH) Consumption kWh 12,340
Total kWh Sold & PH Consumption 366,965
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 172 of 191
Tetlin PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 110
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 44
Community Facility Customers 4
Other Customers (Non‐PCE) 8
Fiscal Year PCE Payments $40,687
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 133,190 Average Annual PCE Payment per Eligible
Customer
$848
PCE Eligible kWh ‐ Community Facility
Customers
67,432 Average PCE Payment per Eligible kWh $0.20
Total PCE Eligible kWh 200,622 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.46
Average Monthly PCE Eligible kWh per
Residential Customer
252 Last Reported PCE Level (per kWh) $0.29
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,405 Effective Residential Rate (per kWh) $0.18
Average Monthly PCE Eligible Community
Facility kWh per Person
51 PCE Eligible kWh vs Total kWh Sold 59.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons) 0
Non‐Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold $0
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.00
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 155,529 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
$0
Community Facility kWh Sold 67,615 Line Loss (%) $0
Other kWh Sold (Non‐PCE) 113,587 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 336,731 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 336,731
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Utility is intertied to another facility and does not generate power for sales to its customers.
Page 173 of 191
Thorne Bay; Kasaan PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 621
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 336
Community Facility Customers 31
Other Customers (Non‐PCE) 122
Fiscal Year PCE Payments $40,350
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 1,109,005 Average Annual PCE Payment per Eligible
Customer
$110
PCE Eligible kWh ‐ Community Facility
Customers
328,971 Average PCE Payment per Eligible kWh $0.03
Total PCE Eligible kWh 1,437,976 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.29
Average Monthly PCE Eligible kWh per
Residential Customer
275 Last Reported PCE Level (per kWh) $0.04
Average Monthly PCE Eligible kWh per
Community Facility Customer
884 Effective Residential Rate (per kWh) $0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
44 PCE Eligible kWh vs Total kWh Sold 41.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons) 0
Non‐Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold $0
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.00
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,692,573 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
$0
Community Facility kWh Sold 329,966 Line Loss (%) $0
Other kWh Sold (Non‐PCE) 1,430,580 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 3,453,119 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 75,502
Total kWh Sold & PH Consumption 3,528,621
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Utility is intertied to another facility and does not generate power for sales to its customers.
Page 174 of 191
Togiak PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 893
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 228
Community Facility Customers 19
Other Customers (Non‐PCE) 76
Fiscal Year PCE Payments $322,917
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 914,297 Average Annual PCE Payment per Eligible
Customer
$1,307
PCE Eligible kWh ‐ Community Facility
Customers
249,464 Average PCE Payment per Eligible kWh $0.28
Total PCE Eligible kWh 1,163,761 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.51
Average Monthly PCE Eligible kWh per
Residential Customer
334 Last Reported PCE Level (per kWh) $0.27
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,094 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
23 PCE Eligible kWh vs Total kWh Sold 40.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 3,076,705 Fuel Used (Gallons) 220,344
Non‐Diesel kWh Generated 0 Fuel Cost $592,884
Purchased kWh 0 Average Price of Fuel $2.69
Total Purchased & Generated 3,076,705 Fuel Cost per kWh sold $0.21
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.21
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,113,988 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
93.7%
Community Facility kWh Sold 541,138 Line Loss (%) 4.6%
Other kWh Sold (Non‐PCE) 1,226,253 Fuel Efficiency (kWh per Gallon of Diesel)13.96
Total kWh Sold 2,881,379 PH Consumption as % of Generation 1.7%
Powerhouse (PH) Consumption kWh 52,311
Total kWh Sold & PH Consumption 2,933,690
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 175 of 191
Tok; Tanacross PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 1349
Last Reported Month June
No. of Monthly Payments Made 13
Residential Customers 756
Community Facility Customers 29
Other Customers (Non‐PCE) 190
Fiscal Year PCE Payments $602,274
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 2,729,228 Average Annual PCE Payment per Eligible
Customer
$767
PCE Eligible kWh ‐ Community Facility
Customers
218,142 Average PCE Payment per Eligible kWh $0.20
Total PCE Eligible kWh 2,947,370 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.46
Average Monthly PCE Eligible kWh per
Residential Customer
278 Last Reported PCE Level (per kWh) $0.29
Average Monthly PCE Eligible kWh per
Community Facility Customer
579 Effective Residential Rate (per kWh) $0.18
Average Monthly PCE Eligible Community
Facility kWh per Person
12 PCE Eligible kWh vs Total kWh Sold 38.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 9,323,086 Fuel Used (Gallons) 643,007
Non‐Diesel kWh Generated 0 Fuel Cost $1,452,498
Purchased kWh 0 Average Price of Fuel $2.26
Total Purchased & Generated 9,323,086 Fuel Cost per kWh sold $0.19
Annual Non‐Fuel Expenses $2,567,355
Non‐Fuel Expense per kWh Sold $0.34
Total Expense per kWh Sold $0.53
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 3,730,451 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
81.3%
Community Facility kWh Sold 218,742 Line Loss (%) 16.7%
Other kWh Sold (Non‐PCE) 3,633,465 Fuel Efficiency (kWh per Gallon of Diesel)14.50
Total kWh Sold 7,582,658 PH Consumption as % of Generation 2.0%
Powerhouse (PH) Consumption kWh 186,280
Total kWh Sold & PH Consumption 7,768,938
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 176 of 191
Toksook Bay PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 656
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 133
Community Facility Customers 15
Other Customers (Non‐PCE) 29
Fiscal Year PCE Payments $228,925
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 614,963 Average Annual PCE Payment per Eligible
Customer
$1,547
PCE Eligible kWh ‐ Community Facility
Customers
322,673 Average PCE Payment per Eligible kWh $0.24
Total PCE Eligible kWh 937,636 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.50
Average Monthly PCE Eligible kWh per
Residential Customer
385 Last Reported PCE Level (per kWh) $0.24
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,793 Effective Residential Rate (per kWh) $0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
41 PCE Eligible kWh vs Total kWh Sold 58.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,775,870 Fuel Used (Gallons) 241,640
Non‐Diesel kWh Generated 956,308 Fuel Cost $680,708
Purchased kWh 0 Average Price of Fuel $2.70
Total Purchased & Generated 3,732,178 Fuel Cost per kWh sold $0.42
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.42
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 804,274 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
43.1%
Community Facility kWh Sold 501,552 Line Loss (%) 53.1%
Other kWh Sold (Non‐PCE) 304,381 Fuel Efficiency (kWh per Gallon of Diesel)11.49
Total kWh Sold 1,610,207 PH Consumption as % of Generation 3.7%
Powerhouse (PH) Consumption kWh 139,864
Total kWh Sold & PH Consumption 1,750,071
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 177 of 191
Tuluksak PCE
Utility: TULUKSAK TRADITIONAL
Reporting Period: 07/01/17..06/30/18
Community Population 363
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 101
Community Facility Customers 6
Other Customers (Non‐PCE) 14
Fiscal Year PCE Payments $88,490
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 230,645 Average Annual PCE Payment per Eligible
Customer
$827
PCE Eligible kWh ‐ Community Facility
Customers
41,576 Average PCE Payment per Eligible kWh $0.33
Total PCE Eligible kWh 272,221 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.75
Average Monthly PCE Eligible kWh per
Residential Customer
190 Last Reported PCE Level (per kWh) $0.38
Average Monthly PCE Eligible kWh per
Community Facility Customer
577 Effective Residential Rate (per kWh) $0.37
Average Monthly PCE Eligible Community
Facility kWh per Person
10 PCE Eligible kWh vs Total kWh Sold 54.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 602,705 Fuel Used (Gallons) 52,842
Non‐Diesel kWh Generated 0 Fuel Cost $194,848
Purchased kWh 0 Average Price of Fuel $3.69
Total Purchased & Generated 602,705 Fuel Cost per kWh sold $0.39
Annual Non‐Fuel Expenses $65,134
Non‐Fuel Expense per kWh Sold $0.13
Total Expense per kWh Sold $0.52
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 247,521 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
83.5%
Community Facility kWh Sold 41,576 Line Loss (%) 7.0%
Other kWh Sold (Non‐PCE) 213,990 Fuel Efficiency (kWh per Gallon of Diesel)11.41
Total kWh Sold 503,087 PH Consumption as % of Generation 9.5%
Powerhouse (PH) Consumption kWh 57,211
Total kWh Sold & PH Consumption 560,298
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 178 of 191
Tuntutuliak PCE
Utility: TUNTUTULIAK COMMUNITY
Reporting Period: 07/01/17..06/30/18
Community Population 454
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 110
Community Facility Customers 7
Other Customers (Non‐PCE) 31
Fiscal Year PCE Payments $106,889
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 418,179 Average Annual PCE Payment per Eligible
Customer
$914
PCE Eligible kWh ‐ Community Facility
Customers
20,002 Average PCE Payment per Eligible kWh $0.24
Total PCE Eligible kWh 438,181 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.65
Average Monthly PCE Eligible kWh per
Residential Customer
317 Last Reported PCE Level (per kWh) $0.29
Average Monthly PCE Eligible kWh per
Community Facility Customer
238 Effective Residential Rate (per kWh) $0.36
Average Monthly PCE Eligible Community
Facility kWh per Person
4 PCE Eligible kWh vs Total kWh Sold 47.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 921,620 Fuel Used (Gallons) 88,980
Non‐Diesel kWh Generated 107,510 Fuel Cost $235,210
Purchased kWh 54,194 Average Price of Fuel $2.64
Total Purchased & Generated 1,083,324 Fuel Cost per kWh sold $0.26
Annual Non‐Fuel Expenses $400,382
Non‐Fuel Expense per kWh Sold $0.43
Total Expense per kWh Sold $0.69
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 477,596 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
85.1%
Community Facility kWh Sold 36,898 Line Loss (%) 12.1%
Other kWh Sold (Non‐PCE) 407,081 Fuel Efficiency (kWh per Gallon of Diesel)10.36
Total kWh Sold 921,575 PH Consumption as % of Generation 2.8%
Powerhouse (PH) Consumption kWh 30,608
Total kWh Sold & PH Consumption 952,183
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 179 of 191
Tununak PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 387
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 89
Community Facility Customers 9
Other Customers (Non‐PCE) 26
Fiscal Year PCE Payments $103,948
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 347,802 Average Annual PCE Payment per Eligible
Customer
$1,061
PCE Eligible kWh ‐ Community Facility
Customers
65,874 Average PCE Payment per Eligible kWh $0.25
Total PCE Eligible kWh 413,676 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.50
Average Monthly PCE Eligible kWh per
Residential Customer
326 Last Reported PCE Level (per kWh) $0.24
Average Monthly PCE Eligible kWh per
Community Facility Customer
610 Effective Residential Rate (per kWh) $0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
14 PCE Eligible kWh vs Total kWh Sold 41.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons) 0
Non‐Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold $0
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.00
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 397,064 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
$0
Community Facility kWh Sold 236,707 Line Loss (%) $0
Other kWh Sold (Non‐PCE) 360,450 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 994,221 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 994,221
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 180 of 191
Twin Hills PCE
Utility: TWIN HILLS VILLAGE COUNCIL
Reporting Period: 07/01/17..06/30/18
Community Population 85
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 33
Community Facility Customers 5
Other Customers (Non‐PCE) 8
Fiscal Year PCE Payments $40,324
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 108,557 Average Annual PCE Payment per Eligible
Customer
$1,061
PCE Eligible kWh ‐ Community Facility
Customers
34,252 Average PCE Payment per Eligible kWh $0.28
Total PCE Eligible kWh 142,809 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.51
Average Monthly PCE Eligible kWh per
Residential Customer
274 Last Reported PCE Level (per kWh) $0.27
Average Monthly PCE Eligible kWh per
Community Facility Customer
571 Effective Residential Rate (per kWh) $0.23
Average Monthly PCE Eligible Community
Facility kWh per Person
34 PCE Eligible kWh vs Total kWh Sold 52.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 308,334 Fuel Used (Gallons) 31,612
Non‐Diesel kWh Generated 0 Fuel Cost $89,361
Purchased kWh 0 Average Price of Fuel $2.83
Total Purchased & Generated 308,334 Fuel Cost per kWh sold $0.33
Annual Non‐Fuel Expenses $21,809
Non‐Fuel Expense per kWh Sold $0.08
Total Expense per kWh Sold $0.41
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 119,847 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
88.0%
Community Facility kWh Sold 34,252 Line Loss (%) 2.8%
Other kWh Sold (Non‐PCE) 117,235 Fuel Efficiency (kWh per Gallon of Diesel)9.75
Total kWh Sold 271,334 PH Consumption as % of Generation 9.2%
Powerhouse (PH) Consumption kWh 28,219
Total kWh Sold & PH Consumption 299,553
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 181 of 191
Unalakleet PCE
Utility: UNALAKLEET VALLEY ELECTRIC
Reporting Period: 07/01/17..06/30/18
Community Population 758
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 270
Community Facility Customers 21
Other Customers (Non‐PCE) 88
Fiscal Year PCE Payments $213,539
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 1,018,953 Average Annual PCE Payment per Eligible
Customer
$734
PCE Eligible kWh ‐ Community Facility
Customers
350,398 Average PCE Payment per Eligible kWh $0.16
Total PCE Eligible kWh 1,369,351 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.44
Average Monthly PCE Eligible kWh per
Residential Customer
314 Last Reported PCE Level (per kWh) $0.16
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,390 Effective Residential Rate (per kWh) $0.28
Average Monthly PCE Eligible Community
Facility kWh per Person
39 PCE Eligible kWh vs Total kWh Sold 34.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 3,441,700 Fuel Used (Gallons) 228,032
Non‐Diesel kWh Generated 972,128 Fuel Cost $567,670
Purchased kWh 0 Average Price of Fuel $2.49
Total Purchased & Generated 4,413,828 Fuel Cost per kWh sold $0.14
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.14
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,312,929 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
89.6%
Community Facility kWh Sold 607,626 Line Loss (%) 6.5%
Other kWh Sold (Non‐PCE) 2,032,903 Fuel Efficiency (kWh per Gallon of Diesel)15.09
Total kWh Sold 3,953,458 PH Consumption as % of Generation 4.0%
Powerhouse (PH) Consumption kWh 174,940
Total kWh Sold & PH Consumption 4,128,398
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 182 of 191
Unalaska PCE
Utility: CITY OF UNALASKA
Reporting Period: 07/01/17..06/30/18
Community Population 4448
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 750
Community Facility Customers 58
Other Customers (Non‐PCE) 197
Fiscal Year PCE Payments $654,258
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 1,849,828 Average Annual PCE Payment per Eligible
Customer
$810
PCE Eligible kWh ‐ Community Facility
Customers
2,983,706 Average PCE Payment per Eligible kWh $0.14
Total PCE Eligible kWh 4,833,534 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.50
Average Monthly PCE Eligible kWh per
Residential Customer
206 Last Reported PCE Level (per kWh) $0.16
Average Monthly PCE Eligible kWh per
Community Facility Customer
4,287 Effective Residential Rate (per kWh) $0.34
Average Monthly PCE Eligible Community
Facility kWh per Person
56 PCE Eligible kWh vs Total kWh Sold 8.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 57,918,250 Fuel Used (Gallons) 3,643,265
Non‐Diesel kWh Generated 0 Fuel Cost $8,248,912
Purchased kWh 0 Average Price of Fuel $2.26
Total Purchased & Generated 57,918,250 Fuel Cost per kWh sold $0.15
Annual Non‐Fuel Expenses $4,666,412
Non‐Fuel Expense per kWh Sold $0.08
Total Expense per kWh Sold $0.23
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 3,781,131 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
95.6%
Community Facility kWh Sold 3,139,512 Line Loss (%) 2.9%
Other kWh Sold (Non‐PCE) 48,430,124 Fuel Efficiency (kWh per Gallon of Diesel)15.90
Total kWh Sold 55,350,767 PH Consumption as % of Generation 1.5%
Powerhouse (PH) Consumption kWh 867,659
Total kWh Sold & PH Consumption 56,218,426
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 183 of 191
Upper Kalskag PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 231
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 65
Community Facility Customers 2
Other Customers (Non‐PCE) 29
Fiscal Year PCE Payments $77,937
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 273,697 Average Annual PCE Payment per Eligible
Customer
$1,163
PCE Eligible kWh ‐ Community Facility
Customers
9,150 Average PCE Payment per Eligible kWh $0.28
Total PCE Eligible kWh 282,847 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.50
Average Monthly PCE Eligible kWh per
Residential Customer
351 Last Reported PCE Level (per kWh) $0.26
Average Monthly PCE Eligible kWh per
Community Facility Customer
381 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
3 PCE Eligible kWh vs Total kWh Sold 34.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,563,307 Fuel Used (Gallons) 110,859
Non‐Diesel kWh Generated 0 Fuel Cost $297,258
Purchased kWh 0 Average Price of Fuel $2.73
Total Purchased & Generated 1,563,307 Fuel Cost per kWh sold $0.37
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.37
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 358,838 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
51.8%
Community Facility kWh Sold 122,615 Line Loss (%) 45.9%
Other kWh Sold (Non‐PCE) 328,023 Fuel Efficiency (kWh per Gallon of Diesel)14.10
Total kWh Sold 809,476 PH Consumption as % of Generation 2.3%
Powerhouse (PH) Consumption kWh 36,593
Total kWh Sold & PH Consumption 846,069
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 184 of 191
Venetie PCE
Utility: VENETIE VILLAGE ELECTRIC
Reporting Period: 07/01/17..06/30/18
Community Population 192
Last Reported Month June
No. of Monthly Payments Made 11
Residential Customers 104
Community Facility Customers 9
Other Customers (Non‐PCE) 13
Fiscal Year PCE Payments $103,541
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 178,345 Average Annual PCE Payment per Eligible
Customer
$916
PCE Eligible kWh ‐ Community Facility
Customers
98,877 Average PCE Payment per Eligible kWh $0.37
Total PCE Eligible kWh 277,222 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.90
Average Monthly PCE Eligible kWh per
Residential Customer
156 Last Reported PCE Level (per kWh) $0.39
Average Monthly PCE Eligible kWh per
Community Facility Customer
999 Effective Residential Rate (per kWh) $0.51
Average Monthly PCE Eligible Community
Facility kWh per Person
47 PCE Eligible kWh vs Total kWh Sold 51.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 712,941 Fuel Used (Gallons) 51,259
Non‐Diesel kWh Generated 0 Fuel Cost $203,566
Purchased kWh 0 Average Price of Fuel $3.97
Total Purchased & Generated 712,941 Fuel Cost per kWh sold $0.37
Annual Non‐Fuel Expenses $19,750
Non‐Fuel Expense per kWh Sold $0.04
Total Expense per kWh Sold $0.41
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 214,206 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
76.2%
Community Facility kWh Sold 112,106 Line Loss (%) 20.2%
Other kWh Sold (Non‐PCE) 216,694 Fuel Efficiency (kWh per Gallon of Diesel)13.91
Total kWh Sold 543,006 PH Consumption as % of Generation 3.6%
Powerhouse (PH) Consumption kWh 25,748
Total kWh Sold & PH Consumption 568,754
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 185 of 191
Wainwright PCE
Utility: NORTH SLOPE BOROUGH
Reporting Period: 07/01/17..06/30/18
Community Population 557
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 151
Community Facility Customers 3
Other Customers (Non‐PCE) 72
Fiscal Year PCE Payments $4,799
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 428,188 Average Annual PCE Payment per Eligible
Customer
$31
PCE Eligible kWh ‐ Community Facility
Customers
61,789 Average PCE Payment per Eligible kWh $0.01
Total PCE Eligible kWh 489,977 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.18
Average Monthly PCE Eligible kWh per
Residential Customer
236 Last Reported PCE Level (per kWh) $0.00
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,716 Effective Residential Rate (per kWh) $0.18
Average Monthly PCE Eligible Community
Facility kWh per Person
9 PCE Eligible kWh vs Total kWh Sold 8.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 7,469,315 Fuel Used (Gallons) 557,941
Non‐Diesel kWh Generated 0 Fuel Cost $1,440,928
Purchased kWh 0 Average Price of Fuel $2.58
Total Purchased & Generated 7,469,315 Fuel Cost per kWh sold $0.23
Annual Non‐Fuel Expenses $1,148,359
Non‐Fuel Expense per kWh Sold $0.19
Total Expense per kWh Sold $0.42
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,445,649 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
82.4%
Community Facility kWh Sold 61,789 Line Loss (%) 11.0%
Other kWh Sold (Non‐PCE) 4,649,399 Fuel Efficiency (kWh per Gallon of Diesel)13.39
Total kWh Sold 6,156,837 PH Consumption as % of Generation 6.6%
Powerhouse (PH) Consumption kWh 492,192
Total kWh Sold & PH Consumption 6,649,029
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 186 of 191
Wales PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 167
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 47
Community Facility Customers 5
Other Customers (Non‐PCE) 23
Fiscal Year PCE Payments $69,381
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 174,383 Average Annual PCE Payment per Eligible
Customer
$1,334
PCE Eligible kWh ‐ Community Facility
Customers
44,676 Average PCE Payment per Eligible kWh $0.32
Total PCE Eligible kWh 219,059 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.56
Average Monthly PCE Eligible kWh per
Residential Customer
309 Last Reported PCE Level (per kWh) $0.31
Average Monthly PCE Eligible kWh per
Community Facility Customer
745 Effective Residential Rate (per kWh) $0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
22 PCE Eligible kWh vs Total kWh Sold 36.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 645,091 Fuel Used (Gallons) 50,715
Non‐Diesel kWh Generated 0 Fuel Cost $145,090
Purchased kWh 0 Average Price of Fuel $2.79
Total Purchased & Generated 645,091 Fuel Cost per kWh sold $0.24
Annual Non‐Fuel Expenses $130,215
Non‐Fuel Expense per kWh Sold $0.22
Total Expense per kWh Sold $0.46
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 224,660 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
92.5%
Community Facility kWh Sold 141,276 Line Loss (%) 3.7%
Other kWh Sold (Non‐PCE) 230,827 Fuel Efficiency (kWh per Gallon of Diesel)12.72
Total kWh Sold 596,763 PH Consumption as % of Generation 3.8%
Powerhouse (PH) Consumption kWh 24,745
Total kWh Sold & PH Consumption 621,508
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 187 of 191
Whale Pass PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/17..06/30/18
Community Population 45
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 80
Community Facility Customers 2
Other Customers (Non‐PCE) 14
Fiscal Year PCE Payments $24,093
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 186,335 Average Annual PCE Payment per Eligible
Customer
$294
PCE Eligible kWh ‐ Community Facility
Customers
9,051 Average PCE Payment per Eligible kWh $0.12
Total PCE Eligible kWh 195,386 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.29
Average Monthly PCE Eligible kWh per
Residential Customer
194 Last Reported PCE Level (per kWh) $0.04
Average Monthly PCE Eligible kWh per
Community Facility Customer
377 Effective Residential Rate (per kWh) $0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
17 PCE Eligible kWh vs Total kWh Sold 59.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 381,621 Fuel Used (Gallons) 29,431
Non‐Diesel kWh Generated 0 Fuel Cost $69,053
Purchased kWh 0 Average Price of Fuel $2.35
Total Purchased & Generated 381,621 Fuel Cost per kWh sold $0.21
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.21
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 240,574 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
85.6%
Community Facility kWh Sold 9,051 Line Loss (%) 11.1%
Other kWh Sold (Non‐PCE) 77,214 Fuel Efficiency (kWh per Gallon of Diesel)12.97
Total kWh Sold 326,839 PH Consumption as % of Generation 3.3%
Powerhouse (PH) Consumption kWh 12,600
Total kWh Sold & PH Consumption 339,439
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Utility is intertied to another facility and does not generate power for sales to its customers.
Page 188 of 191
White Mountain PCE
Utility: CITY OF WHITE MOUNTAIN
Reporting Period: 07/01/17..06/30/18
Community Population 209
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 65
Community Facility Customers 8
Other Customers (Non‐PCE) 29
Fiscal Year PCE Payments $89,548
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 234,714 Average Annual PCE Payment per Eligible
Customer
$1,227
PCE Eligible kWh ‐ Community Facility
Customers
109,053 Average PCE Payment per Eligible kWh $0.26
Total PCE Eligible kWh 343,767 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.55
Average Monthly PCE Eligible kWh per
Residential Customer
301 Last Reported PCE Level (per kWh) $0.26
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,136 Effective Residential Rate (per kWh) $0.29
Average Monthly PCE Eligible Community
Facility kWh per Person
43 PCE Eligible kWh vs Total kWh Sold 46.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 821,952 Fuel Used (Gallons) 65,332
Non‐Diesel kWh Generated 0 Fuel Cost $158,372
Purchased kWh 0 Average Price of Fuel $2.42
Total Purchased & Generated 821,952 Fuel Cost per kWh sold $0.21
Annual Non‐Fuel Expenses $183,075
Non‐Fuel Expense per kWh Sold $0.24
Total Expense per kWh Sold $0.46
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 270,442 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
91.0%
Community Facility kWh Sold 109,053 Line Loss (%) 3.2%
Other kWh Sold (Non‐PCE) 368,270 Fuel Efficiency (kWh per Gallon of Diesel)12.58
Total kWh Sold 747,765 PH Consumption as % of Generation 5.9%
Powerhouse (PH) Consumption kWh 48,122
Total kWh Sold & PH Consumption 795,887
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 189 of 191
Yakutat PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/17..06/30/18
Community Population 594
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 272
Community Facility Customers 29
Other Customers (Non‐PCE) 149
Fiscal Year PCE Payments $351,732
PCE Statistical Data
PCE Eligible kWh ‐ Residential Customers 1,039,278 Average Annual PCE Payment per Eligible
Customer
$1,169
PCE Eligible kWh ‐ Community Facility
Customers
387,939 Average PCE Payment per Eligible kWh $0.25
Total PCE Eligible kWh 1,427,217 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.45
Average Monthly PCE Eligible kWh per
Residential Customer
318 Last Reported PCE Level (per kWh) $0.26
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,115 Effective Residential Rate (per kWh) $0.19
Average Monthly PCE Eligible Community
Facility kWh per Person
54 PCE Eligible kWh vs Total kWh Sold 27.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 6,030,952 Fuel Used (Gallons) 403,107
Non‐Diesel kWh Generated 0 Fuel Cost $1,082,225
Purchased kWh 0 Average Price of Fuel $2.62
Total Purchased & Generated 6,030,952 Fuel Cost per kWh sold $0.21
Annual Non‐Fuel Expenses $0
Non‐Fuel Expense per kWh Sold $0
Total Expense per kWh Sold $0.21
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,260,158 Consumed vs Generated (kWh Sold vs
Generated‐Purchased)
86.0%
Community Facility kWh Sold 1,121,316 Line Loss (%) 11.7%
Other kWh Sold (Non‐PCE) 2,802,702 Fuel Efficiency (kWh per Gallon of Diesel)14.96
Total kWh Sold 5,184,176 PH Consumption as % of Generation 2.3%
Powerhouse (PH) Consumption kWh 140,670
Total kWh Sold & PH Consumption 5,324,846
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Some
changes to the data have been made to account for reporting irregularities. Please contact AEA if you have questions.
Page 190 of 191
SAFE,
RELIABLE, &
AFFORDABLE
ENERGY
SOLUTIONS
ALASKA ENERGY AUTHORITY
813 West Northern Lights Blvd.
Anchorage, Alaska 99503
Phone: (907) 771-3000
Fax: (907) 771-3044
Toll Free 888-300-8534
www.akenergyauthority.org