HomeMy WebLinkAboutWater Current Turbines Tech Eval Verdent Power Rpt 06-15-2006
Technology Evaluation
of
Existing and Emerging Technologies
Water Current Turbines for River Applications
Prepared for
Natural Resources Canada
Contract # NRCan-06-01071
June 15, 2006
Prepared by
Verdant Power Canada ULC
261 Martindale Road, Suite 5
St. Catharines, ON L2W 1A2
905-688-5757
905-688-3502 (fax)
www.verdantpower.com
WCT Evaluation NRCan-06-01071
TABLE OF CONTENTS
EXECUTIVE SUMMARY ................................................................................................4
1 INTRODUCTION .....................................................................................................5
2 TECHNOLOGY BACKGROUND ............................................................................6
2.1 Water Current Technologies (WCT) Definition.................................................................................6
2.2 General State of Technology ................................................................................................................7
2.3 Issues Affecting Commercialization ....................................................................................................7
2.3.1 Environmental Research .............................................................................................................................7
2.3.2 Technical Research .....................................................................................................................................7
2.3.3 Site Assessment Data and Resource Potential ............................................................................................8
2.3.4 Funding for Demonstration and Deployment .............................................................................................8
2.3.5 Permitting Issues ........................................................................................................................................8
2.3.6 Coordination among Regulatory Authorities ..............................................................................................8
3 COMPANIES AND TECHNOLOGIES .....................................................................9
3.1 Survey of Established and Emerging WCT Companies ....................................................................9
3.2 Company and Technology Summary Table .....................................................................................10
3.3 Types of NTR Devices .........................................................................................................................12
3.3.1 Axial Flow Turbines .................................................................................................................................12
Water Current Turbine- THROPTON ENERGY SERVICES ......................................................................12
Amazon AquaCharger - MARLEC/ THROPTON ENERGY SERVICES (UK)..........................................13
Kinetic Hydropower System (KHPS) - VERDANT POWER, LLC AND VERDANT POWER CANADA
ULC (USA, Canada).....................................................................................................................................14
Tidal Turbine Generator- CLEAN CURRENT POWER SYSTEMS- (Canada)..........................................15
Underwater Electric Kite - UEK CORPORATION (USA)...........................................................................16
Hydroreactor Stream Accelerator - PEEHR (Portugal).................................................................................17
Hydrohélix Turbine- HYDROHÉLIX ENERGIES (France)........................................................................18
Tidal Stream Turbine- SWANTURBINES (UK)..........................................................................................19
3.3.2 Cross-Axis Turbines .................................................................................................................................20
Darrieus Turbine- ALTERNATIVE HYDRO SOLUTIONS LTD (Canada)...............................................20
Cross-Axis Turbine- ENERGY ALLIANCE (Russia)..................................................................................21
ENEMAR with Kobold Turbine- PONTE DI ARCHIMEDE S.P.A. (Italy)................................................22
EnCurrent Hydro Turbine - NEW ENERGY CORPORATION, Inc (Canada)............................................23
Davis Turbine, Mid Range Unit- BLUE ENERGY Company (BEC) (Canada)...........................................24
Gorlov Helical Turbine- GCK TECHNOLOGY, INC (USA)......................................................................25
Diffuser Augmented Water Current Turbine - TIDAL ENERGY PTY LTD (Australia).............................26
CycloTurbine - BOSCH AEROSPACE (USA)............................................................................................27
WPI Turbine- WATER POWER INDUSTRIES (Norway)..........................................................................28
Verdant Power Canada ULC 2
WCT Evaluation NRCan-06-01071
3.3.3 Paddlewheels ............................................................................................................................................29
Floating Power Station- ECO HYDRO ENERGY LTD. - (Canada)............................................................29
RiverBank Hydro Turbine- ENCORE CLEAN ENERGY INC (Canada)....................................................30
3.3.4 Hydraulically Tapped Duct Systems ........................................................................................................31
Rochester Venturi - HYDROVENTURI (UK, USA)....................................................................................31
3.3.5 Fan Belt ....................................................................................................................................................32
Aquanator- ATLANTIS ENERGY- (Australia)............................................................................................32
3.3.6 Flutter Vanes ............................................................................................................................................33
Oscillating Cascade Power System - ARNOLD COOPER HYDROPOWER SYSTEMS (USA)...............33
4 INVESTIGATING ENERGY PRODUCTION ESTIMATES:...................................34
4.1 Technology Performance ....................................................................................................................34
5 INVESTIGATING PRODUCTION COST ESTIMATES ..........................................36
5.1 General Considerations ......................................................................................................................36
5.2 Component Cost Breakdown .............................................................................................................37
5.3 Developer Disclosures .........................................................................................................................37
5.4 Industry Analyses ................................................................................................................................38
6 CANADA IN PERSPECTIVE .................................................................................39
6.1 Canadian WCT Companies and Technology ...................................................................................39
6.1.1 Review of UK Research Support ..............................................................................................................39
6.1.2 International Development Path Divergences ..........................................................................................39
6.2 WCT Resource Potential in Canada..................................................................................................40
6.2.1 NTR WCT Resource ................................................................................................................................40
6.3 Canadian Government Support.........................................................................................................41
6.3.1 Funding.....................................................................................................................................................41
6.3.2 Research ...................................................................................................................................................41
6.3.3 Permitting .................................................................................................................................................41
6.3.4 Regulations ...............................................................................................................................................41
7 SUMMARY ............................................................................................................42
APPENDIX 1 -- DEFINITIONS ......................................................................................43
APPENDIX 2 - DEVELOPER CONTACT INFORMATION ...........................................45
Verdant Power Canada ULC 3
WCT Evaluation NRCan-06-01071
Executive Summary
In response to a Natural Resources Canada (NRCan) request, Verdant Power has prepared the report “Technology
Evaluation of Existing and Emerging Technologies: Water Current Turbines for River Applications”. The report
highlights the current state of development of hydrokinetic technologies referred to as water current turbines
(WCT) that could or are being applied to river applications.
Section 1 introduces the document and defines the points of NRCan’s original request.
Section 2 provides some definitions that form the basis of the report and background on the state of development
of the technologies. Also included are some of the areas critical to future development of a river-based Canadian
industry such as:
Environmental Research
Technical Research
Site Assessment Data and Resource
Potential Funding for Demonstration and Deployment Permitting Issues
Coordination among Regulatory Authorities
Section 3 describes the various technologies, their applicability to river or tidal situations, and the stage of their
development. Table 1 summarizes this information and groups the technologies by appropriate subcategories.
Section 4 discusses technical performance of the various devices. Table 2 summarizes the size, flow and power
characteristics as provided by the various developers.
Section 5 explores the cost of bringing the units to commercial implementation based on published information
provided by the developers. Figures in sections 5.2 and 5.3 provide a breakdown of capital cost and developers’
projection of installed cost per kW.
Section 6 draws out some of the relevant points from British development programs in the ocean and tidal area
that may be relevant to Canadian efforts to promote and develop a river based hydrokinetic industry. Key
components for consideration include:
• Creating market pull and reducing financial risk
• Developing the role of EMEC
• Establishing Scotland as the centre for marine energy certification
• Developing a supportive planning and regulatory framework
• Providing a route to market
• Developing academic capacity and supporting R&D
• Supporting skills and manufacturing capability
Section 6 also provides recommendations of key steps Canadian federal and provincial governments may wish to
consider to promote the development of WCT’s in Canada.
Section 7 summarizes the report.
Verdant Power hopes this report provides NRCan a useful tool for first assessments of emerging technologies and
highlights some of the areas where government effort can be critical to moving the industry forward. We would
welcome the opportunity to work with NRCan to explore opportunities to advance the state of the industry
through developing protocols for and implementing resource assessment, development of regulatory processes
that streamline the timing for deploying technologies, or any aspect of encouraging this emerging technology that
NRCan feels we may be of assistance.
Verdant Power Canada ULC 4
WCT Evaluation NRCan-06-01071
1 Introduction
In response to Natural Resources Canada’s (NRCan) Request for Proposals on Water Current Turbines
Technologies (WCT) for River Applications, Verdant is providing this report “Technology Evaluation
of Existing and Emerging Water Current Turbines Technologies for River Applications.”
The five major objectives of this report are to:
• Evaluate the present status of WCT technologies being developed in Canada and
internationally and their state of development – The report provides a brief review of the state
of technological development for WCT or hydrokinetic devices and issues reflecting their move
to commercialization (need for research funding, need for site assessment data and resource
potential, funding for demonstration and deployment, permitting issues and the need for
coordinated policies among regulatory authorities). The report also provides a brief review of
international development at the European Marine Energy Centre and UK research support, in
general.
• Describe the types of WCT technology and their technical parameters – The report provides
a brief description of each technology and a table listing the important defining parameters for
each technology.
• Investigate energy production estimates of the technologies under review – For each
technology, the report will provide a table of various size ranges provided by the vendors and
their estimated unit energy production (e.g., KHPS 5m-diameter, 35 kWh based on 2 metres /
second).
• Estimate cost of energy production – The report will provide vendors’ own current estimates
and their self-assessed current state of development as well as published independent industry
information so that Natural Resources Canada can make an independent judgment on whether
there is sufficient data to support the cost estimate.
• Analysis of Canadian technologies with respect to international developments The report
discusses the current state sponsored research and the opportunity for development on a general
global scale (overview of British research, brief description of Scottish plans for offshore
generation, lack of a US program, brief description of New York and California programs, broad
global opportunity).
Please Note:
All currency figures in this report are given in Canadian dollars. Original data given in other currency is converted based on
Bank of Canada nominal noon exchange rates, as published on 20-4-2006. Figures are not adjusted for inflation in the case of
previously published data.
Verdant Power Canada ULC 5
WCT Evaluation NRCan-06-01071
2 Technology Background
2.1 Water Current Technologies (WCT) Definition
Water Current Turbines (WCT’s) are defined as systems that convert hydro kinetic energy from flowing
waters into electricity, mechanical power, or other forms of energy, such as hydrogen. WCT’s are
generally types of rotor devices, such as underwater windmills, or water wheels, among others. These
devices take advantage of water’s density, which is 850 times greater than air.
Specifically, for this report, Water Current Technologies are defined as follows:
• WCT systems rely mainly on the existing kinetic energy in the water stream. They do not
rely upon any artificial water-head, such as impoundments, to be created as the energy
source for operation. For this report, WCT systems are limited to those that create water
level differentials no more than one metre greater than before installation or operation.
• WCT systems do not require large civil works, but they can be placed in existing tailraces
and channels, utilizing the kinetic energy available.
• WCT systems operate instream, defined here as the water stream’s natural pathway. They
do not require the diversion of water through manmade channels, riverbeds, or pipes,
although they may have applications in such conduits.
• WCT systems may operate in unidirectional and/or bi-directional (tidal) flowing waters
• WCT systems do not require that the water height change (as in tides) for operation
although some are suited for tidal applications.
• WCT systems do not require waves for operation
For the scope of this report the focus was on applications in Non-Tidal Rivers (NTR) (i.e., unidirectional
flow) although several of the devices may have application in tidal waters, ocean currents and manmade
channels.
Verdant Power Canada ULC 6
WCT Evaluation NRCan-06-01071
2.2 General State of Technology
Several large scale tidal and ocean demonstrations are now underway, some with private capitalization,
some with government funding. There are demonstrations of WCT’s occurring, however they are, in
general, smaller in size and less publicized. Of those occurring, Canadian companies are well
represented including New Energy, Alternative Hydro Systems, and Eco Hydro Energy.
Technically speaking, WCT’s are now enjoying the benefits of rapid advances in many technologies.
Some of the technologies now solving old problems are durable composite materials, low speed
generators, underwater construction advancements, and fish monitoring technology, CAD-CAM, CFD
modeling, anti-corrosion materials/designs, and high efficiency power electronics.
A major trend that is occurring with tidal WCT’s is the elimination of the gearbox by using new low
speed generators. River applications will benefit from these improvements which will increase the
system efficiency and reduce maintenance costs.
There are several common design themes being pursued by a number of companies. Roughly 1/3 of the
companies are focusing on Darrieus turbines and 1/3 of the companies on axial flow turbines. Ducting
is present on at least half of the designs. More ducting may be on the way as companies look at ways to
utilize slower waterways.
Presently, the demonstrations of WCT’s are generally of single units. However, several companies have
or are now building the first fields of multiple units. With the installation and testing of the first
multiple unit deployments, methods for system integration (e.g., electrical connectivity, grid connection,
control) can be evaluated. In addition the most efficient geometric layout of the fields will be
determined. Much will be validated about the interaction of WCT’s with the environment, but the
science of WCT energy recovery and interaction with the environment will remain an area that requires
considerable research.
2.3 Issues Affecting Commercialization
The following technical, economic, social and environmental issues appear to be temporary hurdles that
will need to be addressed as the industry moves toward the commercialization of WCT’s.
2.3.1 Environmental Research
Some of the early environmental questions will revolve around the following issues:
• Fish, turtle, marine mammal, diving bird behavior and interaction with WCT’s.
• Expensive environmental impact monitoring tests are likely to be required for the first
deployments of new technologies.
• Extensive long term tests can cost millions of dollars which developers are not well positioned to
absorb. These tests would be ideal candidates for government efforts with results available to the
industry.
2.3.2 Technical Research
• Antifouling
• Deployment methodology
• Maintenance techniques
• CFD modeling
• Best field configurations and packing arrangements for best efficiency.
Verdant Power Canada ULC 7
WCT Evaluation NRCan-06-01071
2.3.3 Site Assessment Data and Resource Potential
The identification of sites can prove to be a very imposing, intensive and expensive process for WCT
companies that are skilled in building turbines but not GIS or hydrology issues. However, many
governments have such expertise for cataloging and managing their water resources for other uses.
Governments can assist budding WCT’s companies by providing resource data and expertise as follows:
• Measure (and model) and provide velocity information for more water resources
• Measure and provide bathymetric data for more water resources
• Provide economic and social data
• Modeling focused on icing issues
• Navigation issues
2.3.4 Funding for Demonstration and Deployment
General business technology development grants would aid companies’ pursuing new technologies
through the costly R&D and demonstration phases. Government funding partnerships for prototypes
would reduce the financial burden of demonstrating new technologies and allowing for more rapid
development of promising breakthroughs.
2.3.5 Permitting Issues
• Uniform policies on navigational issues
• Standards for fish impact assessments
• Standards for fish monitoring requirements
2.3.6 Coordination among Regulatory Authorities
• Lead agency to coordinate regulatory requirements
• Streamlined well documented permitting process
• Shortened permitting processes for demonstration units intended to provide performance and
environmental data
Verdant Power Canada ULC 8
WCT Evaluation
Verdant Power Canada ULC
NRCan-06-01071
9
3 Companies and Technologies
3.1 Survey of Established and Emerging WCT Companies
For this report, Verdant Power performed an extensive web-based search and reviewed and updated
earlier research performed for the Electric Power Research Institute in 2004. Although this report
focused on WCT technologies for rivers, the search first entailed locating all WCT companies,
regardless of their site application. Once the companies were identified, the site application of their
technology was determined: non-tidal rivers (NTR), tidal areas (rivers or straits), and unidirectional
ocean currents.
In many cases WCT technologies are suitable for multiple site types. The most critical factor for
whether a tidal system can be applied in a non-tidal application is unit size. The most well publicized
tidal technologies to date have been large systems that need 20 m or more of depth to operate (e.g.,
Marine Current Turbine, Hammerfest-Strom, and The Engineering Business), where the economy of
scale theoretically improves the profitability of development. This limits their applicability in a majority
of non-tidal rivers. However, many of the devices may have the potential to be scaled down to fit a
broader range of river flow and depth characteristics.
For purposes of this report, we have attempted to identify technologies by their applicability to NTR’s as
opposed to the developer’s current market focus. The report emphasizes technologies that are currently
scaled to 1 kW or more. Each vendor’s stage of development is noted; the stages may be defined as
follows:
Laboratory: Scale model testing in a laboratory setting
Prototype: Single unit field test
Pre-commercial: Demonstration of commercial size units
Commercial: Units commercially available
Recent and rapid developments in the WCT industry make separating verifiable technical data from
subjective or promotional public statements a serious challenge. Third-party verification of technical
claims, especially quantitative performance data, is minimal at present, so information about some
technologies is based primarily on qualitative descriptions from the developers. Some of the newest
designs are literally just emerging from laboratory secrecy. For the purposes of this report, the authors
have chosen to include developers’ claims where third party verification is not available in order to
provide NRCan with information on the broadest range of technologies.
WCT Evaluation NRCan-06-01071 3.2 Company and Technology Summary Table Table 1 - WCT Device and Technology Summary Table Company WCT Device Name Turbine Type Stage of Development Turbine Efficiency System Efficiency Min/Max Depth (m) Min/Max Speed (m/s) Blade Pitch Axis Orientation Blade Diameter No. of Turbines per Unit Ducted or Unducted Anchor System AXIAL-FLOW TURBINES Thropton Energy Services Water Current Turbine Axial flow propeller Commercial no data found 12% - 14% @1kW turbine diameter/no limit 0.5/1.5 † fixed horiz 4.0, 3.4, 2.8, 2.2, 1.8m 1 unducted pontoon boat Marlec Amazon Aquacharger Boat-mount Thropton Commercial no data found 12% 1.75/ no limit 0.45/1.5 fixed horiz 1.8 1 unducted boat or dock Verdant Power Canada ULC Kinetic Hydro Power Sys Axial Flow Pre-Commercial 45% 35.9% 7m for 5m dia. 1.0 / tailored for any speed fixed horiz 5m, scaleable 2m+ 1 unducted yaw pylon Clean Current Tidal Turbine Generator Ducted Axial Flow Prototype no data found 50% no data found no data found no data found horiz prototype: 3.5m 1, possibly 2 ducted pylon, weighted base UEK Underwater Electric Kite Dual Ducted Axial Flow on tether Prototype no data found no data found no data found no data found fixed horiz Several models: 2m, 3m and larger 1 ducted tethered PEEHR Hydroreactor Stream Accelerator Ducted Axial Flow 4 bladed impeller on Prototype no data found ~13% calculated from data no data found test data at 2.75m/s only fixed horiz 1.2 1 ducted extendable yaw pile Hydrohélix Energies Marenergie Axial-flow Laboratory no data found no data found no data found no data found fixed horiz 8 m 1 ducted weighted base? Swan Turbines Swan Turbine Axial flow propeller Laboratory/ Prototype no data found 24% no data found 1.8/2.8 (for 1m proto.) data not found horiz prototype =1m 1 unducted extendable yaw pylon CROSS-AXIS TURBINES Alternative Hydro Solutions Ltd Freestream Darrieus Water Turbine Cross-axis Commercial no data found ~32% calc from graph ~0.6 for high speed stream no data found fixed vert 1.25, 1.5, 2.5, 3.0, 6.0 metres 1 unducted Customer determined Energy Alliance Submerged Hydro Unit Cross-axis Commercial 80% † 65% † 0.5/unlimited 3/10 † fixed horiz no data found 1 ducted weighted base & cabled Ponte di Archimede Kobold Turbine Cross-axis flow Pre-Commercial no data found 23% ~7 m / unlimited tested at 2m/s; range data not found varies vert 6 m dia x 5 m high 1 unducted Floating buoy with mooring cables to anchors Verdant Power Canada ULC 10
NRCan-06-01071 11 WCT Evaluation Verdant Power Canada ULC New Energy EnCurrent Hydro Turbine Cross-axis Pre-Commercial no data found Unducted:28% Ducted: 55% no data found with 5kW Gen: 1.5/ 1.7 duct. 2.0/3.0 unducted fixed vert 1.6 for 5kW 1 ducted & unducted unknown Blue Energy -Canada Mid Range Davis Hydro Turbine Darrieus, cross-axis Prototype no data found no data found 10†/ no data found 1.74/ TBD † fixed vert 6.10 † 2 ducted floating GCK Technology Gorlov Helical Turbine Helical Darrieus Cross-axis Prototype ~20-38% TBD Vert: no min/limitHoriz: ~1.1 0.6 /no limit fixed either 1 1 or more sections unducted various Tidal Energy Pty. Ltd. TBD Darrieus, cross-axis Prototype no data found no data found no data found no data found fixed vert 1.2 to 2.4 2 ducted unknown Bosch Aerospace CycloTurbine Cycloidal Turbine Laboratory 39.6% † (ducted) 29.3% † (ducted) TBD TBD varies horiz TBD 1 ducted & unducted various Water Power Industry WPI Turbine Darrieus cross-axis Prototype 49.9 No data found TBD TBD varies vert TBD 1 unducted unknown PADDLEWHEEL TURBINES Eco Hydro Energy Ltd Floating Power Station Paddlewheel Prototype no data found no data found no data found no data found flexing paddles horiz Various dia’s; e.g. 240MW has 18m wheel + 14m blades 1 or 2 in prototype Modules link unducted boat-like float Encore Clean Energy Inc River Bank Turbine Turntable Paddlewheel Laboratory no data found no data found no data found no data found NA, folding bucket vert no data found multiple ducted floating platform HYDRAULICALLY TAPPED DUCT SYSTEMS Hydro Venturi Rochester Venturi duct with hydraulic tap & air turbine Prototype no data found 20% † <1m/100 1.5 /30.5 NA NA NA 1 or more RV’s can share 1 airturbine ducted weighted base? FANBELTS Atlantis Energy Aquanator Fan-belt Prototype no data found no data found ~10/ no data found 1.0/no data found fixed NA 9m tall x 57m wide 1 belt unducted no data found FLUTTERVANESArnold Cooper Hydropower Systems Oscillating Cascade Power System Fluttervane Laboratory 58-61% † TBD 1.5/15 † 1.5/4.5 † flutters vert 7.3 x 3.0 x 0.9 N/A N/A no data found NOTE: Most of the information presented is gathered from the company’s own website or published literature without third party confirmation and should be evaluated in light of each design-developer's experience and track record to date. † Data Source: Renewable Energy Technical Assessment Guide - TAG-RE: 2004 Report - Product Number 000000000001008366. Published Dec 2004.
WCT Evaluation NRCan-06-01071
3.3 Types of NTR Devices
The following companies were determined to be viable companies for NTR WCT. In some cases the
technology may be marketed solely for tidal applications, but the authors believe that the technology
was well suited for NTR’s, as is or with minor modifications.
3.3.1 Axial Flow Turbines
Water Current Turbine- THROPTON ENERGY SERVICES
Technology: Thropton is the designer, licensor, and component manufacturer of pontoon-mounted low-
power turbines that are used for either electricity generation or for water pumping (for irrigation,
drinking water, etc.). The propeller fan style turbine, available in diameters of 4.0, 3.4, 2.8, 2.2, and
1.8m drives an above-water generator. Its “Garman
Turbine” is used to drive water pumping versions.
Currently, the turbines are designed as stand-alone units
having a maximum power output of about 2 kW. The
system efficiency is fairly low at 12%-14% (@ 1 kW).
The efficiency of individual components (turbine, drive
trains, or generators) is not provided by Thropton. The
device is deployed by mooring in the free-flowing stream
to a post on one bank or another. Minimum site
requirements for this turbine are a water current speed of
at least 0.50 m/s and a depth approximately equal to the
turbine diameter.
Application: Rivers and unidirectional channels. The systems are easily deployed without heavy
equipment and thus they are suitable for use in developing countries. The pontoon unit is usually
positioned in a free-flowing stream with a cable mooring to a post on one bank and a whisker pole
keeping the boat off the bank, or it is moored to an in-river piling.
Stage of Development:
Although this system has been commercially operating for over twenty years according to the company
in Somalia, Sudan, Egypt, and Peru, it does not appear to be scalable for utility power requirements.
Commercial plans are being sold and the design license can be bought for local manufacturing.
Verdant Power Canada ULC 12
WCT Evaluation NRCan-06-01071
Amazon AquaCharger - MARLEC/ THROPTON ENERGY SERVICES (UK)
Technology: Marlec has teamed up their engineering, renewable energy and manufacturing expertise
with Thropton Energy Services, a company specializing in water turbines, to develop a battery charging
water current turbine. The Amazon AquaCharger is a turbine, generator and control system designed to
mount on an ordinary open moored boat (see below). It is sold as a
kit. The turbine is lowered into a river or canal deeper than 1.75 m
and generates power between water flow speeds of 0.45 m/s (1 mph or
0.87 knots) and 1.5 m/s (3.36 mph or 2.92 kn). The use of a high
efficiency, low friction alternator and aerodynamic blade design has
achieved the low water current speed cut-in, maximizing the potential
application to a variety of waterways. Power generated is stored in
batteries to operate 12V appliances and inverters to operate 240V
appliances. Output connectors allow up to six 12V batteries to be
charged simultaneously. The unit starts charging at 0.5m/s river
speed and generates approximately 500 watts at 1.5 m/s. The unit
incorporates a patented furling device that lifts the turbine out of the
water if the river speed exceeds the pre-set maximum. An electrical
brake is operated when furled to prevent the turbine from
freewheeling, reducing wear and tear. The turbine diameter is 1.8 m
and the rotor is protected from going aground and from floating
debris. The system is simple to assemble, dismantle and transport for
relocation. There are minimal running costs and it can run for 24 hours per day unattended.
Application: The Amazon AquaCharger is suitable for areas of the world where large sectors of the
population live in dispersed communities along major river and canal banks. The product offers
opportunities to establish battery charging stations to serve the local population.
Stage of Development: It is manufactured in kits by Marlec, commercially available.
Verdant Power Canada ULC 13
WCT Evaluation NRCan-06-01071
Kinetic Hydropower System (KHPS) - VERDANT POWER, LLC AND VERDANT POWER
CANADA ULC (USA, Canada)
Technology: The KHPS is a 5m diameter 3-bladed axial- flow turbine
rated at 35 kW, which incorporates a patented blade design by New
York University having a high efficiency over a large range of speeds.
The turbine rotor drives a speed increaser, which drives a grid-
connected, three-phase, induction generator. The gearbox and
generator are in a waterproof streamlined nacelle, which is mounted on
a streamlined pylon. The pylon assembly has internal yaw bearings
allowing it to pivot the turbine with the direction of the tidal current,
ebb or flood. The pylon is bolted via an adjustable adapter to a pile
fixed to the river bottom. The turbine will operate below 1.0 m/s but
for economic efficiency it recommends velocities greater than of 2.0
m/s and water depths of at least 6.5 metres.
Application: Rivers, tidal estuaries, and near shore ocean. The
company is also developing smaller and larger diameter turbines. The
smaller systems will be well suited for dam outflows, aqueducts, water
transmission systems, and effluent streams. Higher or lower capacity generators can be placed in the
systems to adapt to higher or lower site velocities.
Stage of Development: The Company is proceeding with the second phase of a three-phase project, to
install six 5 m diameter pre-commercial models each producing 35.9kW at peak (an installed capacity of
between 150 and 200kW) in New York City’s East River by the summer of
2006. A $1.7 million fish behavioral monitoring program has been started on
the site and will be carried through the full installation of the 6 turbines.
Previously, the blade design has been studied and CFD modeled by the Navy. A
1 m, 3 m and 5 m diameter turbines have been tested in both laboratory and field
applications. Units were successfully tested for the maximum efficiency with
little or no deterioration throughout a wide range of stream flow speeds, as might
typically be found in rivers subjected to natural water flow variations or
upstream dam management. In 2003 a 3 m prototype model tested in the East
River generated 15.5 kW at 2.13 m/s, yielding efficiency (Cp) of 43%.
Verdant Power Canada ULC 14
WCT Evaluation NRCan-06-01071
Tidal Turbine Generator- CLEAN CURRENT POWER SYSTEMS- (Canada)
Technology: Clean Current’s tidal turbine generator is a bi-directional ducted horizontal axis turbine
with a direct drive variable speed permanent magnet generator. One version of the system may
incorporate dual side by side turbines with protective screens. Operability is enhanced by a simple
design that has one moving part -the rotor assembly that combines turbine and generator functions. The
blades have permanent magnets attached to them, and the duct incorporates the coils. There is no drive
shaft and no gearbox. The developer states that the proprietary design delivers better than 50 per cent
water-to-wire efficiency. The turbine generator has an estimated design life of 10 years (major overhaul
every 10 years) and a service life of 25-30 years. The turbine, mounted on a pile in about 15 m of water,
is completely underwater and causes no visual impact on marine environments. Commercial scale
models are expected to be 14 m in diameter and produce approximately 250 kW.
Application: Tidal sites greater than 15 m deep appears to be focus, but the device could be used in
deeper rivers.
Stage of Development: Clean Current is a key partner in the “Clean Current Tidal Power
Demonstration Project at Race Rocks Ecological Reserve” about 10 nautical miles southwest of
Victoria. The $4 million project is a partnership between Pearson College, EnCana Corporation of
Canada, and Clean Current Power Systems of Vancouver. EnCana is investing $3 million in the project
from its environmental innovation fund. The project is expected to produce more than enough electricity
to replace two diesel generators and provide power to the college's marine education centre on Great
Race Rock Island by 2006. Clean Current developed and built the prototype of a tidal turbine generator
which harnesses the power of ocean currents to produce electricity. Testing will take place in about 15 m
of water. The prototype being tested is 3.5 m in diameter and can produce approximately 10 kW. The
unit has been tested in fresh water, but will be scrutinized closely over the next 18 months to see how it
holds up to corrosion resulting from a marine, saltwater environment. Financial figures and schedule
projections reflect the views of the developer only and not any independent assessment.
Verdant Power Canada ULC 15
WCT Evaluation NRCan-06-01071
Underwater Electric Kite - UEK CORPORATION (USA)
Technology: This system employs two axial-flow turbines in a "side-by-side" configuration. Each
turbine consists of five blades that drive a single internal generator housed within the nacelle. The
double-shroud surrounding the two side-by-side turbines is constructed of composite materials. The
system incorporates an augmenter ring that is integral with the rear edge of the shroud. The augmenter
ring extends outwardly with respect to the axial alignment of the turbine shafts and deflects the flow of
water about the shroud. This creates a low pressure zone at the rear of the shroud that "pulls" water
through the turbine blades at a velocity greater than that of the normal or surrounding flow of water. The
unit is positively buoyant and is secured to the seabed by a single anchorage system, using a cable
bridle. When flown as a kite the angle-of-attack is altered by a patented ballasting system that shifts a
weight forward and back in the keel. Keeping a controlled operational depth, the units are not affected
by the surface effect of large waves or navigation. Lateral positioning controls permit the units to stay in
the core of the current.
Applications: The turbine is designed to operate in river, tidal and
ocean currents. Various models exist from 2m to 5m and operate
in extremely low velocities of 0.20 m/s or less.
Stage of Development: UEK has field tested at least five different
WCT configurations since the mid 1980’s. Tests include tugboat
drag tests and a tailwater test in Ontario, Canada. The specific
results from these field tests are proprietary.
In 2006 UEK reached an agreement with ATEC Power Inc. to build a
Atlantic Canada. ATEC Power was founded in 2005 to sell tidally generated electricity to Nova Scotia
Power. Preliminary tidal current studies by ATEC Power show the most favorable site for tidal power
generation is Minas Passage between Cape Split and Cape Blomidon. The company plans to conduct
site mapping and evaluation studies in spring and summer 2006.
nd use these underwater turbines in
lso in 2006, Manitoba Hydro initiated and committed funding for a kinetic turbine research project. A
Additional funding is anticipated as part of a collaboration with UEK and the University of Manitoba.
The project will assess the impact, reliability, and operation of a 60 kW kinetic flow turbine in
Manitoba. The turbine is planned to be connected into the distribution grid, and be studied for one year,
beginning in 2006.
Verdant Power Canada ULC 16
WCT Evaluation NRCan-06-01071
Hydroreactor Stream Accelerator - PEEHR (Portugal)
Technology: This technology consists of a cylindrical duct with a unique “Hydroreactor” profile that is
immersed in streams, attached to an elevating platform by
means of a yaw bearing, the platform connected by means of an
extendable piling anchored at the riverbed or seafloor. The
inside duct is composed of a funneling compression zone, an
intermediate narrow venturi zone and finally an expanding
exhaust zone where a suction effect is generated by the
diffusion of the inside flow and deflection of the outside stream.
The duct is automatically and passively oriented according to
the stream’s current direction. A debris screen is attached to the
duct. A low pressure/high speed axial flow turbine is located at
the narrowest section of the duct. The turbines drive a low rpm
generator housed in a watertight chamber located at the duct edge. The
unit’s location is marked by a floating buoy. Maintenance is performed
by lifting the duct above the water surface. An extendable scissors
platform positions the unit for operations or maintenance. The duct’s
inside dimensions are roughly 1.2 m at its narrowest, 5.4 m at its widest
and 8.4 m long. The axial flow 4 blade impeller has a diameter of 1.2 m.
The system is designed for 30 kW at 2.75 m/s. The ducting increases the
stream velocity through the duct by 40% with no turbine installed.
Applications: Rivers, Tides, Ocean Currents
tage of Development: Prototypes of the duct and impeller have been
S
tested under a catamaran which was motored to simulate flowing water.
Verdant Power Canada ULC 17
WCT Evaluation NRCan-06-01071
Hydrohélix Turbine- HYDROHÉLIX ENERGIES (France)
Technology: This ducted axial-flow turbine is designed to be arranged in a row or a matrix. The turbine
spins very slowly at 6 rpm. The turbines are 8 metres in diameter and will generate 250kW each in their
proposed setting 20 m below the English Channel off the coast of France. The French National Centre
for Scientific Research (CNRS) has already tested the effect of the underwater turbines on fish. Since
the blades rotate slowly, at six rotations a minute, fish are unlikely to be unwittingly caught up in the
blades. In addition, the noise from the turbines is not expected to be greater than the average background
noise generated by turbulent water.
Application: The turbine is designed to operate in both river and tidal currents.
Stage of Development: A 60W model of an underwater power station has been tested. The Company is
proposing to start a 1 MW demo of four underwater turbines in the English Channel within the six
kilometre coastal zone from which fishing boats are excluded. Hydrohélix Energies has already
received approximately $280,000 from the French government, and now hopes to attract investors and
engineering firms to build the first stations. They project a kilowatt of electricity will be selling at
approximately $0.06.
Verdant Power Canada ULC 18
WCT Evaluation NRCan-06-01071
Tidal Stream Turbine- SWANTURBINES (UK)
Technology: The unit is a three-bladed axial flow turbine. A gearless low speed generator offers a high
efficiency over a range of speeds with minimal maintenance demands through the use of novel structural
and electromagnetic topologies. To minimize CapEx and OpEx, offshore specialist CB&I John Brown
transferred standard offshore technology and operations to form the basis for a new support structure
concept. A simple, robust and serviceable yawing mechanism is used for maximum flow capture and the
use of patented materials, developed by Corus will form the gravity base. In collaboration with the
University of Wales Swansea, using rotor-dynamic modeling, the concept was designed to allow simple
stallation and maintenance retrieval in both shallow and deep water and to minimize vibrations, hence
stimated 1.5 kW output
is being tested.
the concept design and specification for a technology demonstrator. The design
hase of the project is expected to run until the end of June 2006. The partners are currently seeking
nding to build and install the demonstration device in 2006-7. The total value of the project is
estimated at $608,000.
Overall Schedule:
2006 Design and develop medium scale demonstrator cost optimization and modeling
2008 Install and operate medium scale demonstrator (350kW)
2010 Design and commission pre-commercial system
2011 Sales
in
increasing the maintenance period. Currently, a 1m diameter prototype with an e
Application: Deep and shallow water tidal applications, but could be used in non tidal rivers.
Stage of Development: The project partners are currently cost optimizing the design for a technical
feasibility demonstration. This Collaborative Industrial Research Project is managed by Swansea
University to prepare
p
fu
Verdant Power Canada ULC 19
WCT Evaluation NRCan-06-01071
3.3.2 Cross-Axis Turbines
Darrieus Turbine- ALTERNATIVE HYDRO SOLUTIONS LTD (Canada)
Technology: These small Darrieus turbines are constructed of high quality and durable materials. The
turbine blades are custom 6063T5 aluminum extrusions with a solid cross-section in order to provide the
required strength. The 6063T5 alloy offers excellent resistance to corrosion and a smooth surface finish.
The mating to the hub is performed with a patentable mechanism, which incorporates a second female
extrusion to the arms male. The shaft is made of stainless steel and is supported by two standard
stainless steel pillow block bearings. The frame supporting the two bearings is a standard channel
section or flat plate, which may be modified to
accommodate a variety of mounting mechanisms. The
power is transferred through a flexible coupling to a
otor and gearbox combination which allows the motor
ue fluctuations. A number of
wer versus velocity for various
ombinations of diameter and height.
table for smaller
o that it better fits the cross-section of
ve been incorporated over the previous designs
ning the turbine efficiency. Typically these units have been mounted on a pontoon, barge,
r small boat; however, for smaller streams other methodologies may be more cost effective. These
ould include a built-in support beam extending either fully or partially over the river.
tage of Development: AHS is one of the few companies now building and selling production systems.
hey have performed testing in the past with NRCan and are now collaborating with the University of
indsor (Ontario) on the Green Corridor project, where they successfully demonstrated a boat-mounted
rbine.
m
to run at a higher rpm thereby increasing its efficiency
and reducing the torq
electrical options are available depending on site
requirements. These include a permanent magnet D.C.
generator and a brushless alternator. The turbine is
available in several diameters: 1.25 m, 1.5m, 2.5 m, 3.0
m, and 6.0 m, each available in custom lengths. The
chart indicates the po
c
Application: AHS has taken the Darrieus concepts and modified them to be more sui
rivers. The diameter of the turbine is larger than the height s
shallow sites. A number of design simplifications ha
while maintai
o
c
S
T
W
tu
Verdant Power Canada ULC 20
WCT Evaluation NRCan-06-01071
Cross-Axis Turbine- ENERGY ALLIANCE (Russia)
Technology:pplications.
ith rectifier, accumulator and switchboard.
ation of 220V and 380V, 50Hz AC. The
imum flow through turbine of 0.46 m3/s flow.
is approximately 3.2 m3/s.
nd tidal waters.
uction. Cost: up to 16 kW is approximately
n up to 60 kW unit is priced around $45,600;
.
This technology uses cross-axis turbines traditionally used for low head dam a
They are housed in a duct that allows them to be placed in a swift flowing river without the use of a
dam. The units are expected to stay reliably secured by hydraulic and hydrodynamic forces. The
submerged units can be operated the year round, including the case when they are installed in the rivers
with incomplete freezing of the river bed. The Energy Alliance plans to produce two versions of
submerged hydro-units - portable units with outputs from 1 to 5 kW and stationary units with outputs
from 10 kW to 225kW. Portable submerged hydro-units are intended for generation of 12V and 28V
direct current, depending on the parameters of stream
comprises: cross-axis turbine, synchronous generator w
Stationary submerged hydro-units are intended for gener
turbines require a minimum stream speed of 3 m/s and min
The maximum flow through turbine of for the largest system
Application: The turbine is designed to work in both river a
Stage of Development: The turbines are currently in prod
$14,600; an up to 30 kW unit is approximately $25,600; a
and $62,600 is the estimated price for an up to 100 kW unit
flow and generator type. The hydro-unit
Verdant Power Canada ULC 21
WCT Evaluation NRCan-06-01071
ENEMAR A. (Italy) with Kobold Turbine- PONTE DI ARCHIMEDE S.P.
Technology: The ENEMAR system uses a Kobold turbine that was modified by the Aircraft Design and
Aeroflight Dynamics Group (ADAG), part of the Department of Aeronautical Engineering at the
University of Naples. The Kobold Turbine is a vertically oriented, cross-axis turbine with three straight
blades. It is mounted under a buoy and moored with cables to four anchors.
Application: The turbine is designed to operate in rivers, tidal, and ocean currents.
Stage Field research and experiments were conducted on a pre-commercial model with
turbine 6 meters in diameter and blades 5 meters tall. It was installed in the Messina Strait, Italy in
ring 2001. It generated 25 kW at 2.0 m/s.
enerated by marine currents. Together with the Institute of Energy Conversion of the Chinese Academy
f Sciences, studies regarding the application of the ENERMAR system are currently in progress in the
trait of Jintang (Zhoushan Archipelago), People's Republic of China.
of Development:
a
sp
Currently the company is identifying other sites in Europe suitable for producing electrical energy
g
o
S
Verdant Power Canada ULC 22
WCT Evaluation NRCan-06-01071
En )Current Hydro Turbine - NEW ENERGY CORPORATION, Inc (Canada
e minimum water velocity
to 1.5 m/s. EnCurrent technology builds on work carried out by the National Research Council Canada
(NRC) on a Vertical Axis Hydro Turbine. During the 1980s, NRC launched a program to demonstrate
the technical validity of the Vertical Axis Hydro Turbine, terminating the program at the point they felt
the technology was ready for commercialization by the private sector. Based on the design of the
Darrieus Wind Turbine, New Energy’s turbine is able to extract 40% to 45% of the energy in the water
moving through it. One of the unique economic and design advantages of the Darrieus Turbine design is
that it can capture kinetic energy from the water irrespective of the current direction. This property
enables the New Energy turbine to harness the energy contained in both flood and ebb tides.
Furthermore, slowly rotating turbine blades are expected to eliminate fish kill at installations.
The company is currently offering a 5 kW model with plans to introduce a 25 kW model early in 2006,
e shown below:
Technology: The EnCurrent turbine is a vertical axis Darrieus cross-axis turbine, available in both
ducted and non-ducted configurations. The non-ducted configuration uses a 1.6 m diameter x 0.8m tall
turbine and requires a minimum water velocity of 2 m/s to provide effective power output. The ducted
version places that turbine in a 3.0 m wide by 1.0 m tall duct which reduces th
extending to larger sizes in subsequent years. Power output versus velocity curves ar
Application: New Energy Corporation, Inc. is primarily focused on off-
grid mini and micro hydro markets. The company identifies this market as
ff-grid homeowners or businesses located ino
ri
close proximity to a stream,
n
Man-ma
such as irrigation canals
and effluent discharge
canals within industrial complexes.
tag akes and sells water-to-wire production units.
ver or tidal flow and requiring greater than 5 kW but less than 1 MW of
generating capacity. The company has a secondary focus on the grid
connected distributed energy market, mainly in locations where man-made
waterworks can be
utilized for the generatio
of hydroelectric power.
de waterworks
refers to structures that
have been designed and
built to convey water,
S e of Development: New Energy Corporation now m
Verdant Power Canada ULC 23
WCT Evaluation NRCan-06-01071
Davis Turbine, Mid Range Unit- BLUE ENERGY Company (BEC) (Canada)
Technology: This Company uses a ducted 4–bladed fixed pitch Darrieus-type turbine called the Davis
Hydro Turbine. The turbine drives an integrated gearbox and electrical generator assembly. Originally,
Blue Energy had promoted the turbine to operate in a barrage configuration creating a low head
impoundment. The turbines were to be mounted in concrete ducted fence sitting on the river bed or tidal
estuary bottom, directing the water flow through the turbines and supporting the couplers, gearboxes,
and generators above the water level. The top of the structure can serve as a road or rail platform for
servicing the turbines. Since 2000, Blue Energy has shifted its focus to a non-barrage deployment
system called “Midrange Units” where the ducted Davis turbine relies solely on free flow velocity. The
change reflects concerns from fishermen and environmentalists. The mid range units would be of lower
efficiency but easier to construct than a barrage system. BEC’s website also reports that it is pursuing
the development of a 500kW pre-commercial demonstration project off the coast of British Columbia
comprised of two floating 250kW with 6.1 m diameter turbines. They also are developing a “Micro
ower System” WCT, in the 5 to 25kW range.
Stage of Development: After a huge demonstration program in the 1980’s, there has been a noted drop
in visible projects in the last decade. However, in March 2006 Blue Energy announced its partnering in
the UBC Research Capabilities Enhancement Project. The $172,000 project is co-funded by Western
Economic Diversification and the B.C. Ministry of Energy, Mines and Petroleum Resources, and will
benefit Blue Energy, the University of British Columbia and the B.C. renewable ocean energy industry.
Major project components include the design and purchase of experimental equipment for use at the on-
campus towing-tank facility, funding to support the development of computer models and funding to
explore the possibility of establishing an Ocean Engineering Centre at UBC.
P
Application: It is designed for tidal waters, although it could be used in non-tidal applications.
Verdant Power Canada ULC 24
WCT Evaluation NRCan-06-01071
Gorlov Helical Turbine- GCK TECHNOLOGY, INC (USA)
Technolog gy. The
age of Development: In 2004, Verdant Power, assisted by the Massachusetts Technology
CK and
tested four 1m diameter GHT’s mounted on a barge in the Merrimack River of Massachusetts. The
y: GCK is the licensee of the Gorlov Helical Turbine (GHT) patents and technolo
GHT is a cross-axis turbine consisting of one or more long helical blades that run along an imaginary
cylindrical surface of rotation like a screw thread. The helical airfoil blades provide a reaction thrust
perpendicular to the leading edges of the blades that can pull them faster than the fluid flow itself. The
GHT allows a large mass of slow water to flow through, capturing its kinetic energy and utilizing a very
simple rotor. It can be assembled vertically, horizontally or in any other cross-axis combination using a
common shaft and generator for an array of multiple turbines. Generating capacity is proportional to the
number of modules. In its vertical orientation the generator and gearing can easily be positioned above
water. The standard unit is now 1 m in diameter by 2.5 m in length. It starts producing power at
approximately 0.60 m/s, according to studies done in 2004.
Application: The turbine can be operated in tides, non-tidal rivers, or ocean currents. The horizontal
arrangement lends itself well to shallower rivers, tailraces or discharge channels from industrial plants.
St
Collaborative which is part of the Massachusetts Renewable Energy Trust, collaborated with G
project summary and final report can be found at http://www.masstech.org/Project_lst_rslt.asp?ID=54
on MTC’s website. Issues raised in the report include concerns about vibration.
Verdant Power Canada ULC 25
WCT Evaluation NRCan-06-01071
Diffuser Aug (Australia)mented Water Current Turbine - TIDAL ENERGY PTY LTD
orated with the School of Engineering at
Griffith University of Australia to develop and test their Augmented Ducted Darrieus. In 2004 they
Technology: A 1.2 m diameter (a 2.4m unit is under development) Darrieus turbine mounted in a
diffuser duct. The system has been initially demonstrated and tested under a relocatable pontoon, but
the final mooring system is not divulged. The duct is made of multiple metal “rings”, with slots between
each. Each ring is an airfoil in cross-section. The duct flares towards the rear to create lower pressure
region in back of the turbine to increase the natural velocity of the water. The developer claims the duct
boosts the power by 3 times. The axis is vertically oriented.
Application: Tidal and Non-Tidal Rivers
Stage of Development: Tidal Energy has recently collab
received a grant to fabricate and install a 2.4m x 2.4m “Diffuser Augmented Water Current Turbine”
under a relocatable pontoon to collect test data. The results from this testing is not known.
[“Developments in Ducted Water Current Turbin
niversity, PMB 50, Gold Coast Mail Centre, Qld 9726, Australia, 2003]
es” Brian Kirke, School of Engineering, Griffith
U
Verdant Power Canada ULC 26
WCT Evaluation NRCan-06-01071
CycloTurbine - BOSCH AEROSPACE (USA)
Technology: The CycloTurbine, a form of Cycloidal Turbine, is in essence a paddle wheel with
articulating blades. The blades are long, straight, non-varying in width and symmetrical. They are
arranged in parallel around the perimeter of a wheel forming a squirrel cage-like arrangement. The
blades could be oriented vertically or horizontally. The need for bearings at the far end of the blades is
dictated by the length and flexibility of the blade. The pitches of the blades vary independently from
one another as the turbine rotates in the stream. This allows the blades’ individual lift and drag to be
ptimized, giving the system its best overall performance. The turbine has the advantage of working
rbine works by placing a blade broadside to the flow while
e opposing blade is feathered to the local flow. The illustration below shows the blade positions of a
complexity
nd number of water seals. The efficiency can be increased by installing a ramp to “shade” the bottom
f the turbine which is moving upstream against the current. An unducted prototype turbine was
measured to have an efficiency of 39.6% and a water to wire efficiency of 29.3%.
Application: These turbines would work in rivers, tidal estuaries, and in manmade canals. The
horizontal application is particularly well suited to shallow rivers. The system could operate in tidal
applications by reversing the pitch control pattern.
Stage of Development: A small hydro CycloTurbine was demonstrated in a laboratory setting in the
summer of 2002. The development of the CycloTurbine for its primary application in vertical lift-off
aircraft has been moving forward steadily since 2001. In 2006 a new hydro prototype is being
constructed which replaces the belt drive with gears which should increase efficiency.
o
without high head pressures. The CycloTu
th
horizontal Cyclo Turbine. At all other locations the angle-of-attack of each blade is optimized to
produce the maximum power. The maximum power occurs when the turbine tip-speed is equal to 1/3
the flow speed. In a vertical blade arrangement, the generator and bearings could be situated above
water which has great advantages for accessibility during maintenance. It also reduces the
a
o
Verdant Power Canada ULC 27
WCT Evaluation NRCan-06-01071
WPI ay)Turbine- WATER POWER INDUSTRIES (Norw
pplication: These turbines are suitable for tidal straits as well as non-tidal rivers and in manmade
tests with a small model. In 2000 they received a
rant from the Norwegian Research Council of 1 million NOK to build a larger scale prototype for river
Technology: The WPI Turbine is an unducted Darrieus type cross-axis turbine with independent
electric motors controlling the pitch for each blade. From the diagrams it appears that the blades are
symmetrical, straight, and uniform in width. A number of vertical foils are suspended from a horizontal
star down into the running water. The foils' angle of attack is electronic
controlled by chips and special encapsulated motors and based upon the
present water speed. The turbine can be stopped or started by feathering
or un-feathering the blades. The turbine’s rotational speed can also be
controlled by the blade pitch. In normal operation the pitch of each blade
varies independently from the other blades as the turbine rotates allowing
each blade’s individual lift and drag to be optimized throughout 360
degrees of rotation. A third party measured the turbine’s efficiency at
49.9%. The turbine’s physical size, velocity requirements and site
requirements are not publicly available on WPI’s website. WPI is
investigating systems with the following power ratings: 100, 200, 300,
500 and 1000 kW.
A
canal applications, such as hydropower plant tailraces, which are the focus for WPI.
Stage of Development: In 1999 WPI had favorable
g
testing but it was capsized in a river flood. They have continued performing lab testing over several
years. WPI has patents in Eurasia, Australia, OAPI, China, and the EU and pending patents in India,
USA, Canada, Brazil, Japan and Norway.
Verdant Power Canada ULC 28
WCT Evaluation NRCan-06-01071
3.3.3 Paddlewheels
Floating Power Station- ECO HYDRO ENERGY LTD. - (Canada)
Technology: The floating power station is anchored in an existing river system. Flexible rotor blades
are mounted on an axis which rotates, providing a turbine effect. The flexible rotor blades are arranged
along the rotor axle in staggered rows. The blades also extend gradually ou
The effect creates a very high level of torque at the axle. The rotat
conventional electromagnetic generators. The system
also causes an aeration effect which oxygenates the
river at and downstream from the generation site.
The complete unit can be towed from one location to
another thus providing significant level of power
generation on a given site at extremely short notice
and on a highly economical basis. The developer
claims the system can be built in any size from 100
KW hours to 500 megawatt hours dependant upon
power requirement
twards in relation to the axis.
ing assembly directly drives
s as well as river characteristics
cluding depth, width and flow velocity. Because the
extensive testing. While the developer believes the product is
now ready for market, further testing will continue
under the auspices of the Federal University of Itajuba
in the state of Minas Gerais. Manufacturing and
installation protocols are nearing completion to enable
manufacturers in multiple global locations to
manufacture the product to Eco Hydro’s specifications
and quality requirements. The Company is marketing
the technology through a global network of Licensees.
Each Licensee entity will have responsibility for
marketing and sales and also for manufacture,
installation and commissioning of systems.
in
units are modular, larger floating power systems can
be assembled from individual units.
Application: NTR’s. Possibly tidal rivers if platform is allowed to swing around with changing tide.
Depending on the river, floating turbines can be installed in arrays, a fixed distance apart.
Stage of Development: The Company manufactured five prototypes in Brazil with various generating
capacities. These prototypes went through
Verdant Power Canada ULC 29
WCT Evaluation NRCan-06-01071
R ine- ENCORE CLEAN ENERGY INC (Canada)iverBank Hydro Turb
Technology: A el in which the
he energy of the wind or water flow, it rotates the turbine shaft,
roducing high-torque to drive a generator. When the shutter snaps open from the force of the water
and efficiency
r rotates away from the water flow, the shutter closes, like a clam-
system that would incorporate the described turb
a river.
patented high-torque fully submerged folding-vane turntable paddlewhe
buckets are open for the drag portion of the cycle, but folded flat/closed for the upswing and lateral
portions of the rotation. The large flat “shutters” open, like a sail, to create a large surface area that can
optimally capture the force being exerted by on-coming wind or water to rotate the carousel-like device.
As the open shutter is pushed by t
p
flow, hydraulic cylinders connecting the shutters pump pressurized hydraulic fluid, producing high-
pressure hydraulic energy which may power a separate hydraulic motor to boost rotation
of the turbine. As the open shutte
shell, lowering its profile like an aerodynamically-balanced airplane wing to reduce drag resistance
along the drag-side of the rotation into the wind. Encore is also designing a floating partial barrage
ine and could be easily towed into place and moored in
pplication: NTR’s, Tidal, and ocean currents
tage of Development: Encore is constructing operational prototypes of its RiverBank turbine. No test
ata is yet available. Encore is the majority partner in the World, Wind and Water LLC,
A
S
d
Verdant Power Canada ULC 30
WCT Evaluation NRCan-06-01071
3.3.4 Hydraulically Tapped Duct Systems
Rochester Venturi - HYDROVENTURI (UK, USA)
Technology: The Rochester Venturi exploits two simple well known phenomena—it is difficult to
compress water, and, liquid or gas passing over a curved surface will generate a vacuum on the trailing
edge of that surface. These phenomena are described by the Bernoulli Effect. HydroVenturi uses a
technology based on these simple principles to accelerate water through a choke system (see figure
below). The acceleration creates a pressure drop in the device. This pressure drop is used to drive
turbines. Using coupling devices, the turbines can be situated above water or even on shore. This
removes the need for complex moving parts or electrical parts in the water. There are three main
advantages of this method of extracting energy: 1) The absence of moving mechanical or electrical
components in the water implies minimal maintenance costs; 2) The HV systems could be submerged so
that there are no visual impacts and shipping would not be impeded; and 3) The suction output from
several venturis could be connected in parallel to the same generator, providing economy of scale. An
underwater barrage, honeycombed with venturis, can consist of a string of concrete caissons sunk
roughly in a line. These could be re-floated for maintenance or for moving to another site, by pumping
out the water used to flood them when they were sunk. RV’s are modular and can be used to create
systems from 50kW to 500MW which have a 20% water to wire efficiency
, Canada, New York, Iceland and New Zealand. Since 2005, HydroVenturi has been
developing an ultra-low head hydropower demonstrator site in the English Midlands.
.
Application: The system is designed to operate in tidal, ocean, and river currents.
Stage of Development: HydroVenturi has spent the past 3 years developing and improving their
systems by 1) extensive testing in our installation in the North of England, and more recently their
current design near Derby. 2) development of new and improved technologies in the primary system and
in the power take-off and control electronics, 3) development of novel applications in our technology for
low head hydro and tidal sites, 4) in-depth feasibility studies of a range of locations, for example in
Scotland
Verdant Power Canada ULC 31
WCT Evaluation NRCan-06-01071
3.3.5 Fan Belt
Aquanator- ATLANTIS ENERGY- (Australia)
Technology:
The Aquanator use a series of aquafoils (lift vanes) mounted on a belt or chain which slides on an oval
track 57 m across and 9 m high. The structure is mounted completely underwater. Its mooring method
is undisclosed. When the tide shifts the belt rotates in the opposite direction. Flows of about 1.0 m/s
will rotate the aquafoils and generator, producing 1.0 MW of electricity.
Application:
The company’s main focus is capturing the energy of the Australian (ocean) current. Its horizontal
layout and low aspect ratio (height over width) makes it ideal for river applications. The present design
is 9 m tall x 57 m long which limits its use to mid-range and deeper rivers. The device may be scalable
to a smaller configuration which would be appropriate for river applications. It is designed to produce 1
MW at a water velocity of 1 m/s.
Stage of Development:
Prototypes of unknown size have been field tested as seen in the photo. They hope to have up to 25
units in production in the next five years.
Verdant Power Canada ULC 32
WCT Evaluation NRCan-06-01071
3.3.6 Flutter Vanes
Oscillating Cascade Po ER SYSTEMS (USA)
wer System - ARNOLD COOPER HYDROPOW
echnology: In the Arnold Hydroelectric Power System or Oscillating Cascade Power System (OCPS),
are long, straight, non-varying in width and symmetrical (see figures below). They are
is back and forth motion into
tational energy for a generator. The pitch of the blades may be forced mechanically via the gearing or
induced by the unstable path of the water. The blades can be arranged vertically or
wn that a typical 7.32m x 3.05m x 0.91m module in a 3.05 m/s flow will
pplication: Shallow water NTR’s, tidal areas, and manmade channels. The system can be made to
perate easily in reverse for tidal applications.
Stage of Development: Prototypes have been built and run in flow tank settings. Presently, changes are
being made to replace the complex gearing with some other technology, possibly hydraulics. No
commercial units have been built to date.
T
the hydrofoils
arranged in parallel and in foursomes such that the blades are allowed to move towards and away from
each other in a mirroring fashion. The interaction between the blades is quite complex in that the pitch
of the blades is varied and the blades are alternatively attracted and then repulsed by the adjacent blade
such that an oscillating motion is created. The gearing translates th
ro
may be naturally
horizontally to best fit the stream cross section. The efficiency of the system is not known. In a vertical
blade arrangement the generator and gearing could be situated easily above water which has great
advantages for accessibility during maintenance and in reducing the complexity and number of water
seals. The need for bearings at the far end of the blades would be dictated by the length and flexibility
of the blade.
Laboratory tests have sho
produce about 200 kW and 60 percent efficiency in conversion of kinetic hydro energy into electric
power.
A
o
Verdant Power Canada ULC 33
WCT Evaluation NRCan-06-01071
4 Investig duction Estimates:
ating Energy Pro
4.1 Technology Performance
The primary means of quantifying WCT technical performance is by measuring various system
efficiencies. Of primary importance are the efficiency of the turbine, gearing, bearings, generator,
electric power conditioning system, and power transmission system. This can be represented as follows:
• Turbine Efficiency Turbine Impacting Water in PowerKinetic
Turbine of Power Output Shaft Mechanical =
• Total System Efficiency
Turbine Impacting Water in PowerKinetic
Output PowerElectric Ready Grid =
= fWCT = fTurbine x fDrivetrain x fGenerator x fPowerConditioning
The turbine at present is the weakest link in the efficiency chain.
The table below gives the performance characteristics for the units discussed in Section 3.
Table 2 - Device Comparison Based on Turbine Type, Size, Water Velocity, and Unit Power Output
Company Technology Type Turbine Size Water Velocity
[m/s]
Unit Power
Output [kW]
Alternative Hydro
Solutions
Freestream Darrieus
Water Turbine
3.0m dia x 2.5 H 1.4 2.6
Arnold Cooper Oscillating Cascade 7.3 x 3.0 x 0.91 3.04 200
Atlantis Energy “Aquanator”, fan-
belt lift vane
57m wide x 9m
tall
1.29 1,000
Blue Energy-
anada
“Davis Hydro
Turbine”, Ducted
Darrieus
2 turbines @ 6.1m
dia.
no data found 500 = (250 x 2)
C
Bosch Aerospace “CycloTurbine”
Cycloidal Turbine
Prototype is 1m
dia.
no data found no data found
Clean Current Tidal Turbine
Generator, Ducted
Axial
14m no data found ~1 MW
Eco Hydro Energy
td
Floating Power
Station
(2) x 18 m wheel
+ 14 m blades
1.35 m/s
no data found
L
Encore Clean
nergy Inc
Turntable
paddlewheel in
floating ductwork
no data found no data found no data found
E
Energy Alliance “Submerged Hydro-
Unit” Ducted cross-
axis
1-5 kW portable
and >10 kW
stationary unit
no data found 1-5 kW and
>10 kW
GCK Technology “Gorlov Helical
Turbine”, twisted
Darrieus
1.0 m dia. x 2.5 m
long
@1.3 m/s 0.70 kW
Verdant Power Canada ULC 34
WCT Evaluation NRCan-06-01071
Hydro Venturi Hydraulically
tapped Venturi with
no data found
surface air turbine
no data found no data found
Hydroh dia. no data found 250 kW élix “Marénergía”, 8 m
Energies ducted axial
New Energy “EnCurrent Hydro
Turbine” Ducted
Turbine:1.6 m dia
x 0.8 h
2.5 m/s
2.5 m/s
2.8 kW unducted
13.0 kW ducted
Darrieus Duct: 3.0 wide x
1.0 high
Ma lec Axiral, unducted 1.8 m dia 1.5 m/s 0.50 kW
PEEHR “Hydroreactor”,
ducted axial flow
1.2 m dia turbine
in 5.4 m dia duct
2.75 m/s 30 kW
Ponte di Archimede Kobold T urbine 6.0 m dia and 5.0
m high
2.0 m/s 25 kW
SwanTurbines Axial, unducted 1.0 m (small Operating range
1.5 kW
prototype) 1.80 to 2.83
Tidal Energy Pty. Ducted Darrieus no data found
td
no data found no data found
L
Thropton Energy Axial, unducted 4.0, 3.4, 2.8, 2.2, 0.5 to 1.5 up t
Services 1.8 m operating range †
o 2 kW at
12-14% system
efficiency
UEK Dual Axial, ducted 2 90Dual 3 m .57 kW
Verdant Power Axial, unducted 5 m 2.1 35.9 kW
Water Power
Industries
Active Pitch
Controlled Vertical
ata found 200, 300,
500 and 1000
Axis Darrieus
Turbine
No data found No d 100,
NOTE: The da
ta is bas res claim
†Data Source:
ed on manufactu s
Renewab roduct Number
000 lished
le Energy Technical Assessment Guide - TAG-RE: 2004 Report - P
0000 00001008366. Pub Dec 2004.
Verdant Power Canada ULC 35
WCT Evaluation NRCan-06-01071
5 Investigatin C ate
Gener s
rase EPRI’s its soon to be released 2006 study of Tidal In-Stream Power Plants,
s associ tem h been, to d
e m s. Individual developers’
projections of all incl from ity lectricity genera
marketing hype published to attract critical private equity dollars, and a healthy dose of wishful
. More dispas seem oming fro developers l years
ure to real w spec ve from the laborato
testing. Ev ican tor jections can be gleaned from
is em c ligned tidal energy industry.
to t splants from the tidal stream
some degree of reliance mig n proje by this slightly more
r.
etw and tems
red
r kW/installed costs should be lowered due to greate ba
potential operating parameters; i.e., due to the ebb and flow of tides and the in e tidal
units to operat cit y factors on tidal units generally run between 25
. O led and unscheduled maintenance properly sit ystems
operate % of the rcial hould nt
ilability fac aditional hydroelectric plants in the 90% + r
2) Generally deployed in more shallow water, requiring less sophisticated mounting structures,
including less unting related personnel and equipment costs
uni-directional flows of rivers and man made conduits
versus tidal operations. The one way current flow eliminates the need for yawing mechanisms
4) Gener rrosion
5) Some WCT designs hold all electrical components out of the water, reducing the need for
expensive seals, perhaps reducing O&M intervals, and reduced scheduled servicing costs due to
easier access
6) Underwater cabling costs should be lower as WCT units will normally be closer to shore
facilities, as the energy conversion devices will not be far out to sea
7) Smaller, thus more easily manufactured by a greater number of fabricators, using a larger variety
of possible fabrication materials and techniques
Factors suggesting increased WCT costs:
1) Per kW installed costs may be greater due to lower kW system capacity over which to spread
fixed costs such as permitting, site engineering, shore equipment/facilities, transmission costs,
etc.
2) Icing and or debris management costs may be higher than experienced in open tidal areas
g Production
ion
ost Estim s
5.1
To paraph
al Considerat
comments in
the economic
commercial-scale d
ated with WCT sys
monstrations of a
usive costs suffer
s are uncertain. T
eaningful number of system
ere have ate, no long term
a lack of matur in the e tion industry,
thinking sionate analyses to be forthc m those with severa
ry to full of expos
scale field
orld conditions, e
en more so, signif
s
ially those who ha
t detail on cost his
advanced
y and pro
reliance on a growin
Indeed, many of the initial entr
g body of analy
ants in
anating from the
he WCT arena will be tra
losely a
n
industry. Thus
developed secto
ht be made o ctions generated
Cost comparison b
een WCT systems tidal stream sys
Factors suggesting
1) Pe
uced WCT costs:
r capacity factors sed on increased
ability of th
e below certain velo ies, capacit
and 35 %ther than schedu ed WCT s
should
ava
close to 100
tors comparable to tr
costly mo
time. Comme scale systems s have equipme
ange.
3) Reduced mechanical complexity due to
and or variable pitch controls on blades, traits found on many tidal oriented systems,
ally not deployed in salt water, resulting in less co
Verdant Power Canada ULC 36
WCT Evaluation NRCan-06-01071
5.2 Component Cost Breakdown
The most recent comprehensive study 1 of WCT’s closely aligned tidal stream systems confirms internal
analyses conducted by this study’s authors. The cost allocation of capital costs for a generic tidal stream
farm is
as follows:
Breakdown of capital costs for a Tidal
Stream Farm
Project
Management 7%
Grid Connection
13%
Installation 2%
Mechanical and
Electrical 39%
Structure 39%
5.3 Developer Disclosures
evelopers have not yet had any third party sales of their units, much less complete installed,
ed operating systems, and therefore lack any product cost data. In addition, many have not yet
any operating history in real life conditions and thus lack any O&M experience.
Most d
permitt
realized
Scattergraph of Developers' Reported
Installed Costs per kW
6,9237,000
9,000
3,000
4,000
3,000
5,000
1,000
01234
What th reported costs amongst a representative sample
of developers currently engaged in the WCT market. Several factors may explain the variance
what components are included in a typical system (some may
incl
def
resourc
e above graph illustrates is the wide disparity in
including; lack of standard definition as to
ude only the energy conversion device itself with no interconnection support), lack of standard
inition as to operating parameters (some developers assume availability of high velocity natural
es found only in rare instances), and assumed production volumes. Starting at minimal current
uture of Marine Energy, Results of the Marine Energy Challenge: Cost competitiveness and growth of wave and t1 “F idal
stream energy”, The Carbon Trust, UK, January 2006.
Verdant Power Canada ULC 37
WCT Evaluation NRCan-06-01071
produc o jected to be approximately 15%2 , the assumption of
5.4 Industry Analyses
While the quality and quantity of data originated by developers increases there are several key
observations that can currently be made. The first is that instant installed costs are not unfavorable
relative to solar or even conventional hydropower. Nor are they unfavorable relative to wind power costs
at a similar stage of development according to this Carbon Trust historical review3 .
tion v lumes, and with learning curves pro
higher volumes quickly drives down resulting costs. Standardization of these assumptions may
considerably tighten the range of responses.
Over and above relative capital costs comes the question of the resulting cost of energy, which includes
all cost factors such as fuel, O&M, re-furbishments, etc. Again, the closest technological relative to
CT is the slightly more mature tidal stream industry. Recent analyses and projections W
T
performed by
he Carbon Trust (ibid, page 21) in January 2006 indicate opening costs of energy at approximately 9
pence (equal to 18.2 ¢), dropping to as low as 3.5 pence (equal to 7¢) in optimal sites when total
installed capacity reaches approximately 3,000 MW. Again, adjustments need to be made to convert the
conditions of tidal operation to uni-directional river flow and conduit systems. See section 5.1.
2 “Experience Curves for Energy Technology Policy”, IEA, 2000.
3 “Future of Marine Energy, Results of the Marine Energy Challenge: Cost competitiveness and growth of wave and tidal
stream energy”, The Carbon Trust, UK, January 2006.
Verdant Power Canada ULC 38
WCT Evaluation NRCan-06-01071
6 Canada in Perspective
6.1 Canadian WCT Companies and Technology
ix Canadian companies are at the forefront of WCT NTR technology; Alternative Hydro Solutions,
lean Current, New Energy, Eco Hydro Energy Ltd, Verdant Power Canada and Blue Energy. Another
compan n more preliminary design work. All together, the Canadian
sent perhaps half of
ompanies in the world doing so (the others being Energy Alliance and Marlec).
6.1.1 Review of UK Research Support
A review of British efforts is relevant as their efforts can provide a template that Canada can build on to
become a world leader in riverine based hydrokinetic power.
Britain’s efforts have focused primarily on large ocean and tidal applications, Britain’s main testing
facilities are in Scotland around the Orkneys with state-of-the-art facilities at Stromness. Marine Energy
Group (MEG) formed by EMEC to assess the potential for tidal and wave energy development. Very
little of the effort to date has been focused on river development. A key driver in developing British
wave and tidal energy capacity is the economic benefits that will flow from device deployment. The
development of commercial scale wave and tidal farms (as opposed to demonstration projects), and the
rders for devices this will create, are expected to produce significant job benefits.
• Developing the role of EMEC
• Establishing Scotland as the centre for marine energy certification
• Developing a supportive planning and regulatory framework
• Providing a route to market
• Developing academic capacity and supporting R&D
• Supporting skills and manufacturing capability
These same basic steps will need to be incorporated into any Canadian plan to establish world
preeminence in NTR technologies.
6.1.2 International Development Path Divergences
A difference in approach to the harnessing of the potential energy available in the movement of water is
manifesting itself primarily between the UK and other countries. Although there are exceptions, the
trend for UK R&D has been to focus on relatively larger (150 – 300 kW) energy conversion devices.
Due to the size of these units, many of them 30 -40 tonnes and 20 metres tall, they require water depths
ly by offshore locations, with which the UK has
e,
S
C
y Encore Clean Energy Inc is i
companies cover the complete range of WCT technologies including axial flow turbines, cross-axis
turbines, paddlewheels, ducted and un-ducted systems, floating, piling, and weight deployed WCT’s.
They range in size from approximately 1 kW to 1 MW. At least two of the companies, Alternative
Hydro Solutions, and New Energy are selling production units. These two repre
c
o
The next 5 years are considered crucial in determining whether the UK and Scotland in particular, can
build on technology advantage and create a viable domestic and international market for marine energy
devices. The conclusions and suggested actions that follow are not listed in order of priority or sequence.
Rather, they describe a range of complementary themes and issues that MEG believes can and must be
addressed in parallel if marine energy is to make a significant contribution to the Government’s
renewable energy aspirations and targets beyond 2010:
• Creating market pull and reducing financial risk
of 30+ metres. With few exceptions this scale is met on
in relative abundance. The UK may have the world’s most favorable offshore resources of this natur
ratifying its attention to this capacity scale.
Verdant Power Canada ULC 39
WCT Evaluation NRCan-06-01071
Ou side the UK developers are generally t pursuing smaller scale energy conversion devices, many in the
tens of nit. These smaller scale units appear
rs & Estuaries, the Underwood McLellan
td (the UMA Group), March 1980]. In the study, 14 major rivers were evaluated for potential energy
he following table contains the total power estimates found in the 1980 study.
kW capacity range, rather than in the hundreds of kW per u
to be a reflection of the widespread availability of shallower and particularly inland river sites found
commonly throughout the world.
While both approaches envision the installation of significant numbers of units working in tandem to
potentially produce substantial capacity, the UK model seems to be more in keeping with the centralized
power generation model, dependent on a supportive transmission system (including physical
infrastructure as well as amenable policy attributes) more than the non-UK systems.
6.2 WCT Resource Potential in Canada
6.2.1 NTR WCT Resource
A major study of Canada for the NTR WCT potential resource was performed back in 1980 by the UMA
Group [An Evaluation of the Kinetic Energy of Canadian Rive
L
production using “no-head” hydroelectric devices. The study assumed that 1.5 metres per second was
the minimum feasible current velocity. It was further assumed that the minimum cross-section flow
required is 50 metres wide, by 3 metres deep. As the following table (reproduction of Exhibit 1.1 of the
study report) summarizes, three main river reaches and thirteen tidal current cross-sections within two
tidal areas were deemed to meet the minimum criteria, potentially producing 110 megawatt-hours per
year of kinetic energy.
T
Location Total Available Power
(MWh/year) x 106
Average Annual* Power
Output (MWh/year) x 106
Existing Electric Power
Plan Capacity (MWh/year)
x 106
Fraser River - from Strait of
Georgia to Chinee Creek 2.01 0.38
West Coast tidal areas:
-Discovery Passage 10.07 3.54
-Oki 0.54 sollo Channel 1.55
-Cordero Channel 0.34 0.12
Tota .96 4.20 61.81 l (B.C.) 11
Mac
Jean
Sim
kenzie River -from
-Marie Creek to Fort
33.18 3.87 pson
Slav
Slav
e River -from Great e Lake to Brule Point 45.67 8.55
Tota 12.42 1.07 l (N.W.T.) 78.85
Bay of Fundy 20.59 3.85 81.86 (Maritimes)
Cross-section reduction assumptions used to calculate Average Annual Power Output:
Width Depth Navigation Mechanical &
Electrical Efficiency
Fraser River 35% 80% 67% 100%
West Coast 100% 100% 100% 35%
Mackenzie River 80% 67% 67% 35%
Slave River 80% 67% 100% 35%
Bay of Fundy 80% 100% 67% 35%
NOTE: The flows stated above include river and tidal flows. The data is inadequate to try to attribute power to
the different types of flow.
Verdant Power Canada ULC 40
WCT Evaluation NRCan-06-01071
6.3 Canadian Government Support
The following sections deal with key areas that the federal and provincial governments may consider in
order to promote the development of NRT.
6.3.1 Funding
Encourage and fund new commercial hydrokinetic power projects by establishing low cost renewable
energy debt financing instruments/grants that include hydrokinetic power generation as a qualified
generation source to be used to fund construction of hydrokinetic projects.
T
a
o encourage the deployment of renewable, secure, locally distributed hydrokinetic power generation as
qualif so accelerate energy deployment in the following
types of program
policy basis.
cial
research and development rogram rta rs
assume the risk of demonstration projects to test new technologies.
Develop joint federal and provincial program to update the work done on river assessments in 1980 and
to sessment of river, tidal and ocean current that is publicly available to developers
and planners to coordinate optimal use of resources balanced with environmental concerns.
6.3.3 Permitting
C rams to encourage demonstration projects by making a distinction
r commercial development. This would speed the
p ration projects in the water to gather perf nce and environmental information.
In m these dem ations could serve as the basis for conditions for licensing of
f ercial operations.
Develop collab hat coordinate
requirements from all of the jurisdictional agencies, including federal, to avoid duplicative processes and
reduce the time and cost to deploy demonstrat ately co ject
3.4 R ations
E developm rights are allocated through a transparent process that takes into account
provincial, local, and public concerns
ying urce, implement appropriate incentives to
s at the federal and provincial level:
• Renewable Portfolio Standards (RPS)
• Renewable Energy Credits (REC)
• Net Metering Programs
• Feed-in Tariff
6.3.2 Research
Support research, development and deployment projects to collect information on the technical
performance and environmental impacts of hydrokinetic power systems. This should be done on a
rovincial and regional p
P nancial support f merg s wrovide fi or development of e
programs. Such p
ing water technologie
s are extremely impo
ith federal and provin
nt in helping develope
develop uniform as
larify permitting prog
equirements for demonstration projects and long term
between the
rocess to put demonst
formation gathered fro
orma
onstr
ull scale comm
orative permitting programs at the provincial and regional level t
ion and ultim mmercial pro s.
6.egul
nsure that ent
Verdant Power Canada ULC 41
WCT Evaluation NRCan-06-01071
7 Summary
This report is intended to provide NRCan with an overview of the state of development of water current
rbines which can potentially be used to take advantage of Canada’s abundant river resources without
the need for additional impoundments. The report has focused on five critical objectives:
E
A s relative to international developments
he intent is to provide the NRCan with the broadest background on technologies and the state of
development to use in its internal decision process as to how the Canadian federal and provincial
tu
Evaluate the present status of WCT technologies being developed in Canada and internationally
and their state of development
Describe the types of technologies and the parameters
Provide energy production estimates
stimate cost of production
nalyze Canadian technologie
T
governments can best establish policies and programs to aid the development of river based water
current turbines for domestic application and international export.
Verdant Power Canada ULC 42
WCT Evaluation NRCan-06-01071
APPENDIX
at is used for
easuring water velocities at any depth. It is usually mounted to a boat which then would cross the
river. T
the wat hs.
Back or turbine that creates a pressure rise
immediately in front of the obstacle and a slight increase in the elevation of the water (a “bulge”); the
size of ity and the size and permeability of the object. If the
obstacle were too close to the tailwaters of a hydropower operation, this rise in tailwater elevation would
effectiv s the hydropower turbines, decreasing their performance. For this
reason, WCT’s would not be sited immediately downstream of an operating hydropower facility.
Capacity Factor:
Appendix 1 -- Definitions
ADCP - Acoustic Doppler Current Profiler: a computer interfaced sonar device th
m
he ADCP would then be able to construct a two dimensional cross section of the river showing
er velocity at all points and dept
Pressure: any obstacle in a river such as a rock
the bulge depends on the water veloc
ely decrease the head acros
Capacity Factor = []
[] []HrskWpacityorSystemCaGenerator
kWHrsOutputEnergyAnnualActual
8760×
Deployment: the physical structure for mounting a WCT system in a river; also can refer to the act of
actually mounting WCT’s.
Excedences: used in this report to denote the percentage of time within a year a current’s velocity is
equal to or greater than its specified velocity.
Free-Flow Hydropower: Another term for WCT
Green Energy: energy whose production causes minimal negative impacts on the environment with
regard to varying norms.
Hydrokinetic Energy: is the energy associated with the motion of water currents. In the case of WCT,
this energy is found in rivers, tidal and ocean currents, and manmade channels such as aqueducts, canals,
sluices, and tailraces.
Impoundment Hydropower: uses a dam to store water and/or increase the head. Water may be
released either to meet changing electricity needs or to maintain a constant water level.
Water Current Technologies (WCT): devices used to convert the kinetic energy from the motion of
water currents into mechanical and electrical power. The devices do not rely on manmade
impoundments, nor do they greatly restrict water velocities. They also do not create large amounts of
head with blockage or back pressure.
Minimum Start-Up Speed: from a stop, a WCT will usually require a water velocity higher than its
low end operating speed to start spinning. This is because when it is not spinning the turbine blades are
usually in a stall condition. Axial-flow turbines have the highest (worst) minimum start-up speed.
Verdant Power Canada ULC 43
WCT Evaluation NRCan-06-01071
Cross-axis turbines are better in that one usually be in lift position even at zero
speed. Depending on the technology, rou is the start-up speed for WCT. Once up
ver within hours at the desk instead of months in
logies,
ing.
ip Speed Ratio (TSR): the ratio of the velocity at the tip of the turbine blade over the velocity of the
water. hydrodynamic lifting surfaces (hydrofoils) such as axial flow and cross-axis
turbines will have TSR’s greater than 1.0 and are more efficient. WCT’s that employ impulse
lade/buckets such as paddlewheels will have TSR’s less than 1.0 and are less efficient.
ead (< 30 feet); free-flow turbines, and micro hydropower. There are three
eneral types of unconventional hydropower systems: (1) elevation-drop systems; (2) free-flowing
ps. Free-flowing systems use the kinetic energy from the
ater in motion. Micro hydropower sites are 100 kW or less. Micro hydro plants can utilize low heads
or more blades will
ghly 1.0 to 2.5 knots
and running the turbine can usually operate below this start-up speed.
Computational Fluid Dynamic (CFD) Modeling: new software simulation tools that can create a
virtual model of a waterway, or turbine, and predict the behavior of the water flow through it. For river
modeling, the operator can alter flow regimes, stage levels of upstream and downstream reservoirs, and
add in manmade structures such as WCT turbines. Use of such systems may allow WCT resource
nalysts to determine WCT performance in a given ria
the field.
Run-of-River: used to describe hydropower projects in which the flow rate entering an impoundment
equals the flow rate leaving the impoundment in real time. In other words, the water level in the
impoundment remains constant. Run-of-river projects are often used for micro-hydro on steep slopes,
where a small impoundment or natural rock weir acts to divert a portion of the flow through a penstock
ipe which runs down the hill to the turbine. Sometimes WCT’s are called Run-of-River technop
but this can be confus
T
Turbines employing
b
Unconventional Hydropower Technology: unconventional turbine designs are developed for low
power (< 1 MW) and low h
g
river/streams; and (3) micro hydropower projects. An elevation-drop hydropower system is defined as
any arrangement that uses a dam or natural dro
w
or high heads.
Verdant Power Canada ULC 44
WCT Evaluation NRCan-06-01071
Appendix 2 - Developer Contact Information
ompany Website Contact C information
Alternative Hydro
Solutions Ltd.
www.althydrosolutions.com Stephen Gregory, M.A.Sc., P.Eng., President
Alternative Hydro Solutions Ltd.
323 Richmond Street East, Suite 421
Toronto, Ontario M5A 4S7
CANADA
Tel: 416.368.5813
Mobile: 416.570.5813
sdgregory@althydrosolutions.com
Atlantis Energy http://www.atlantisenergy.biz
(website under construction at time of writing)
Mick Perry,
Atlantis Energy Ltd, Level 1,
247 River Street, MacLean,
NSW 2463
Australia
Blue Energy Canada
c
w.bluenergy.comww Martin Burger, President and CEO
Box 29068, 1950 West Broadway In
Vancouver, BC V6J 1Z0
CANADA
Tel: 604-682-2583
General Info: inform@bluenergy.com
Martin Burger: mjb@bluenergy.com
Bosch Aerospace jboschma@islinc.com
(no technology specific webpage available)
LTC (R) James H. Boschma
Bosch Aerospace, Inc.
205 Lawler Drive
Brownsboro, AL 35741
USA
Tel: 256-852-5033
CLEAN CURRENT www.cleancurrent.com Dr. Stephen Allison, President
(website under construction at time of writing)
1025 Belmont Avenue
North Vancouver, BC V7R 1K3
CANADA
Tel: (604) 924 9749
sva@aquaconsult.org
Cooper Union
(Arnold Cooper
Hydropower Systems)
ahmad@cooper.edu
(no technology specific webpage available)
Dr. Jameel Ahmad
Chairman, Dept of Engineering
The Cooper Union for the Advancement of
Science and Art
51 Astor Place
New York, NY 10003-7185
USA
Tel: 212-353-4294
Eco Hydro Energy Ltd www.ecohydroenergy.net
Vancouver, BC
CANADA
info@ecohydroenergy.net
Verdant Power Canada ULC 45
WCT Evaluation NRCan-06-01071
Encore Clean Energy
Inc
www.encorecleanenergy.com Encore Clean Energy Inc.
375 Water Street
Suite 610
6 Vancouver, BC V6B 5C
CANADA
Tel: 604-801-5566
info@encorecleanenergy.com
Energy Alliance http://www.energy-Mr. Anatoly Astafiev
el: 259-91-27
Obvodny Kanal 122
St. Petersburg 198095
Russia
T
Fax: 113-02-07
mail@energy-alliance.spb.ru
alliance.spb.ru/sinke.htm
GCK Technology http://www.gcktechnology.com/GCK/Edward L. Kurth
ad St., Ste. 600
an Antonio, TX 78205
425 Soled
S
USA
Tel: 210-226-0920
kurth@gcktechnology.com
Hydrohélix Energies http://cci-Hervé Majastre,
J.-François Daviau
France
T
enterprises.icomme.fr/public/stand.ph
p?id_stand=418 él. 02 98 10 12 35
o.frhydrohelix-energies@wanado
www.hydroventuri.com North American Office:
401, 22 Battery St.
4114
SA
6-6916
avarro, HydroVenturi Ltd
7 2PP
K
4 3526
HydroVenturi Inc
Suite
San Francisco, CA 9
U
Tel: 408-772-8807, Fax: 408-35
European Office:
Jenny de N
13 Princes Gardens
Kensington, London, SW
U
Tel + 44 (0) 207 59
Fax + 44 (0) 207 594 3526
HydroVenturi
Marlec http://www.marlec.co.uk/products/pro Rutland House
Trevithick Rd
Corby Northants -NN17 5XYds/amozon.htm
1588
400211
rlec.co.uk
UK
Tel. +44 (0)1536 20
Fax: +44 (0)1536
sales@ma
New Energy
Corporation Inc
www.newenergycorp.ca
Clayton Bear
3553— 31st Street NW
Suite 473
Calgary, Alberta T2L 2K7
CANADA
Tel: (403) 260-5240
clayton.bear@newenergycorp.ca
Verdant Power Canada ULC 46
WCT Evaluation NRCan-06-01071
PEEHR http://www.peehr.pt Rua Lúcio de Azevedo, Nº21, 6-D
1600-145 Lisboa,
21 72 650 98
132 30
Portugal
Tel: +351 21 72 650 93
Fax: +351
Mobile: +351 93 10
mailbox@peehr.pt
Ponte di Archimede
S.p.A.
e.com .p.A.
973
049
www.pontediarchimed Ponte di Archimede S
Viale Libertà IS.515
98121 – Messina,
Italy
Tel: +39 090 44
Fax: +39 090 41
info@pontediarchimede.com
SwanTurbines http://www.swanturbines.co.uk/ James Orme
Tel: +44 1792 295217
Fax: +44 1792 295903
Dr Ian Masters
Tel +44 1792 295688
Fax +44 1792 295676
es.co.uk
UK
enquiries@swanturbin
Thropton Energy
Services
ompuserve.com/homhttp://ourworld.c Dr. B. Sexon, Thropton Energy Services
orthumberland, NE65 7HU
288
Physic Lane, Thropton
N
UK
Tel: +44-1669-621
epages/throptonenergy/homepage.htm
Tidal Energy Pty. Ltd none r
x 273
ALM BEACH, QLD, 4221
Mr. Aaron Davidson, Directo
PO Bo
172 Townson Ave
P
Australia
Tel: 61 7 5534 4421
Fax: 61 7 5520 2504
tidalenergy@yahoo.com.au
UEK Corporation www.uekus.com Phillipe Vauthier
PO Box 3124
Annapolis, MD 21403
507
USA
Tel: 410-267-6
info@uekus.com
Verdant Power, LLC www.verdantpower.com Verdant Power Canada, ULC
t. Catherines, ON L2W 1A2
88-3502
Trey Taylor
261 Martindale Road
Suite 5
S
CANADA
Tel: 905-688-5757
Fax: 905-6
ttaylor@verdantpower.com
Verdant Power Canada ULC 47
WCT Evaluation NRCan-06-01071
Water Power
Industries
http://www.wpi.no/Even Evensen, COB
Water Power Industries AS
no: NO 980 313 484
8
obile: +47 90 14 92 96
Enterprise
Lillandveien 20
1390 Vollen,
Norway
Tel: +47 66 79 60 5
M
even@wpi.no
Verdant Power Canada ULC 48