Loading...
HomeMy WebLinkAboutReconnaissance Survey for Hydro Electric Turbine Sites Yukon River Ruby Alaska V3.1TerraSondLtd. 05-20-2009 Reconnaissance Survey for Hydroelectric Turbine Sites YUKON RIVER AT RUBY, ALASKA May 20, 2009 Version 3.1 Prepared for The Yukon River Inter-Tribal Watershed Council Prepared by: TerraSond Ltd. 1617 S. Industrial Way, Suite 3 Palmer, AK 99645 Phone: (907) 745-7215 Web Site: www.terrasond.com PROJECT NO 2009-021 i MAY 2010 TABLE OF CONTENTS 1.0 GEODESY & NAVIGATION .......................................................................................................... 1-1 1.1 GEODETIC NETWORK .................................................................................................................... 1-1 1.1.1 Monument H-1 2009 .......................................................................................................... 1-2 1.1.2 Monument H-2 2009 .......................................................................................................... 1-3 1.1.3 Monument RBY A............................................................................................................... 1-4 1.2 NAVIGATION ................................................................................................................................. 1-5 1.3 TERRESTRIAL SURVEY .................................................................................................................. 1-5 2.0 HYDROGRAPHY ........................................................................................................................... 2-7 2.1 ACQUISITION OF HYDROGRAPHIC DATA .......................................................................................... 2-8 2.1.1 Acquisition of Multibeam data ............................................................................................ 2-8 2.1.2 Acquisition of Side Scan Sonar ........................................................................................ 2-11 2.2 HYDROGRAPHIC PROCESSING ..................................................................................................... 2-13 2.2.1 Application of Control Information .................................................................................... 2-13 2.2.2 Multibeam Echosounder Processing ............................................................................... 2-13 2.2.3 Vessel Editor .................................................................................................................... 2-14 2.2.4 Raw Data Conversion ...................................................................................................... 2-14 2.2.5 Navigation Editor .............................................................................................................. 2-14 2.2.6 Attitude Editor ................................................................................................................... 2-15 2.2.7 Sound Velocity Editor ....................................................................................................... 2-15 2.2.8 GPS Tide Computation and Merge .................................................................................. 2-15 2.2.9 Subset Editor .................................................................................................................... 2-16 2.2.10 Caris BASE Surfaces ....................................................................................................... 2-16 2.2.11 Processing of Side Scan Sonar ....................................................................................... 2-17 2.3 HYDROGRAPHIC PRODUCTS ........................................................................................................ 2-18 2.3.1 Bathymetric DEM gridded dataset and imagery .............................................................. 2-18 2.3.2 Acoustic Intensity Mosaic ..................................................................................................... 2-21 2.3.3 Hazard for Construction and Danger to Navigation List .................................................. 2-22 2.4 IMPORTANT NOTE ....................................................................................................................... 2-26 3.0 HYDROKINETICS ....................................................................................................................... 3-27 3.1 ACQUISITION AND PROCESSING OF DISCHARGE MEASUREMENT .................................................... 3-28 3.2 ACQUISITION AND PROCESSING OF CURRENT MAGNITUDE IMAGERY .............................................. 3-29 4.0 PLANNING INFRASTRUCTURE DEVELOPMENT .................................................................... 4-31 5.0 CONCLUSIONS AND RECOMMENDATIONS ........................................................................... 4-36 PROJECT NO 2009-021 ii MAY 2010 TABLE OF APPENDICES A GEODETIC INFORMATION B CURRENT MAGNITUDE IMAGES C DVD – PROCESSED DATA D FLEDERMAUS DIGITAL PRESENTATION E 2009 TURBINE PLACEMENT POSTER LIST OF TABLES Table One Monument H‐1 2009 1‐2  Table Two Monument H‐2 2009 1‐3  Table Three Monument RBY A 1‐4  Table Four List of Terrestrial Survey Points 1‐6  Table Five Technical information for the Teledyne Odom ES3 MBES 2‐9  Table Six Technical information for the Imagenix Yellowfin Side‐Scan Sonar 2‐12  Table Seven List of Obstructions interpreted from the MBES and SSS data sets 2‐25  LIST OF GRAPHICS Graphic A ‐ Project area, vicinity of Ruby, AK 1‐1  Graphic B ‐ Location of H‐1 2009 1‐2  Graphic C ‐ Monument H‐1 2009 1‐2  Graphic D ‐ Location of H‐2 2009 1‐3  Graphic E ‐ Monument H‐2 2009 1‐3  Graphic F ‐ Location of RBY A 1‐4  Graphic G ‐ Monument RBY A 1‐4  Graphic H ‐ Bathymetric contours generated from the MBES survey 2‐7  Graphic I ‐ Teledyne Odom ES3 Multibeam Echosounder Sonar 2‐8  Graphic J ‐ Preprocessed MBES Matrix as acquired in the field 2‐9  Graphic K ‐ Acquisition of Sound Velocity Profile measurement 2‐10  Graphic L ‐ Navigation tower requiring innovative solutions for remote survey operations 2‐10  Graphic M ‐ Ruby Tribal Council Jon Boat as survey vessel of opportunity 2‐11  Graphic N ‐ Imagenix Side Scan Sonar 2‐11  Graphic O ‐ Side scan sonar coverage area 2‐12  Graphic P ‐ Image of Bathymetric Surface (scaled by depth) 2‐20  Graphic Q ‐ Acoustic Intensity Mosaic Image 2‐21  Graphic R ‐ Geologic Interpretation of the Riverbed near the project site 2‐22  Graphic S ‐ Charted vs. Uncharted boundary for Dangers and Hazards 2‐23  Graphic T ‐ Average discharge behavior on the Yukon River (Water‐Resources Investigations Report 99‐4204) 2‐24  Graphic U ‐ Obstruction locations over project area 2‐25  Graphic V ‐ Zone of Avoidance due to Danger to Navigation obstructions in the vicinity of the 2008 deployment site 2‐25  Graphic W ‐ ADCP Transect lines for current velocity measurements across the Yukon River 3‐27  Graphic X ‐ Ship track line from the ADCP referencing both the geodetic navigation and the bottom tracking navigation 3‐28  Graphic Y ‐ Current Magnitude for Transect G illustrating the current distribution across the alveus 3‐30  Graphic Z ‐ Processed current magnitude images for the nearest three transects to the Power Junction Box 4‐31  Graphic AA ‐ Processed current magnitude for Line A as it flows into the project area of interest 4‐31  Graphic BB ‐ Original choice for 2009 Turbine Site A while in the field 4‐33  Graphic CC ‐ Processed Bathymetry showing locations of infrastructure positions 4‐33  Graphic DD ‐ Slope Analysis with Anchor Sites and Zone of Caution 4‐34  Graphic EE ‐ Image from the Fledermaus Presentation for the profile demonstrated in Graphic CC 4‐34  Graphic FF ‐ Drawing of the TerraSond recommendation for positioning of the anchors and turbine 4‐35  Graphic GG ‐ Image from ESRI Presentation for the river including general geomorphology 4‐35  PROJECT NO 2009-021 iii MAY 2010 PROJECT SUMMARY On May 20, 2009, TerraSond Ltd. (TerraSond) mobilized under contract for Yukon River Inter- Tribal Watershed Council (YRITWC) to Ruby, Alaska. The contract specified the recording, processing, analysis, and presentation of remotely sensed data for the purpose of interpreting the physical characteristics for an In-river Hydrokinetic Power Conversion Proof-of-Concept Project. TerraSond acquired measurements along a 350 m (288,301 m2) stretch of Yukon River. The purpose of this project was to identify optimum candidate sites for turbine placement. The scope of the field effort included establishing a local terrestrial geodetic network, measuring discharge flow, measuring current velocity, measuring bathymetric, and subsurface riverbed reflectivity. TerraSond calculated a Minimally Controlled Geodetic Network for Ruby. Two new monuments were established in the vicinity of the survey area. Simultaneous static GPS measurements were acquired on each monument and incorporated into the control network (H-1 2009, H-2 2009, and RBY A). The Geodetic network was originally measured in WGS84 space and controlled by holding RBY A fixed as the published NGS value. The values initially used for H-1 2009 and H-2 2009 were an average of multiple OPUS solutions, however, these values were slightly deformed in the final computation of the relationships of the Geodetic Network. The primary monument used as the base station transmitting real time kinematic (RTK) corrections is H-1 2009. River elevation was measured each day with RTK corrected GPS receivers in order to measure river stage and to calculate the gradient of the river. The river level receded 68 cm during the acquisition period of this project. The river elevation at the start of project was established as the project datum. All depth values in this report reference this datum, all elevations reference the WGS84 ellipsoid. The relationship of the project vertical datum is 55.000 m above the WGS84 ellipsoid. The final calculated position for H-1 2009 is: LAT: N 64° 44’ 24.82019" LONG: W 155° 29’ 30.75642" ELEVATION: 61.1 m (WGS84 Ellipsoid) TerraSond relied heavily upon the infrastructure of Ruby and the support of the Ruby Tribal Council in order to accomplish our project goals. TerraSond surveyed a Jon Boat owned by the Ruby Tribal Council and established a precision survey vessel of opportunity. TerraSond deployed a roving pole mounted Acoustic Doppler Current Profiler, a pole mounted Multibeam Echosounder, a towed Side Scan Sonar, and various Global Positioning System Equipment. The compass and the heading of the ADCP were calibrated and the moving bottom of the Yukon River was measured. Four across river current velocity profiles were measured along the primary line (Line D) and TerraSond computed a discharge value (11,300 m³/s) at the beginning of the project. Seven across-river roving transects were acquired for with the ADCP at an interval distance of 45.72 m separation. PROJECT NO 2009-021 iv MAY 2010 The bathymetric survey yielded an interpolated surface with consistent and predictable topology across the entire alveus. Only the southern portion of this surface was interpreted for Dangers to Navigation (DtoN) or Hazards for Construction (HforC). The area south of the thalweg was acquired with significant overlap and can be considered to be a fully ensonified riverbed. The portion north of the Thalweg was acquired without overlap and approximately 75% of the surface area was ensonified. Although obstructions were identified in this zone, the portion north of the thalweg has not been interpreted for DtoN nor HforC. The minimum depth measured of the alveus was 2.8 m with a maximum depth in the thalweg was of 13.7 m. The Side Scan Sonar (SSS) acoustic imagery yielded a mosaic image of the river bed. The area acquired for this project is coincident with the contiguous bathymetric data and includes the southern portion of the survey area. Individual records from the SSS were analysis for obstructions and were used in the interpretation of the riverbed geology. A normalized composite of the SSS records was assembled to produce a mosaic image of the riverbed. This composite imagery demonstrates more motion artifact then desired due to the instability of the towed fish in the turbulent environment of the Yukon at this site. Although of low aesthetic quality, the mosaic and the products from the SSS were critical for the identification of DtoN, HforC, and for the geologic interpretation. The confidence associated with targets and geologic interpretation was very high when correlated with the bathymetric geomorphology surface. The delivered products from this effort included: Terrestrial Survey Monuments (Three) Discharge Computation Current Transect Images (Seven) Sound Velocity Measurements River Temperature Measurements Digital Elevation Model Side Scan Mosaic Image Obstruction List Interpretation of the above products resulted in: Generalized Geologic Interpretation for Turbine Riverbed Anchor Infrastructure Hazards for Construction Obstruction List Danger to Navigation Obstruction list Optimum Siting for each Riverbed Anchor Optimum Siting for the Turbine Placement Slope Analysis for Turbine Riverbed Anchor Infrastructure and Cable Placement (pending) Significant obstructions were interpreted from the various datasets and their characteristics were correlated. Both DtoN and HforC were identified and charted. Obstruction classification was beyond the scope of this work, however, all sub-surface obstructions are assumed to be natural. TerraSond recommends avoidance for all obstructions identified during this survey. TerraSond finds significant hydrokinetic power available in the Yukon River at Ruby, Alaska and recommends future development of this resource. We find no significant man-made infrastructure, geographic, or geologic obstruction which would preclude this site from future development for hydrokinetic power conversion activity. Although obstructions exist within the project boundaries, it is the opinion of TerraSond that no obstacles were identified that cannot be avoided, remediated, or otherwise overcome through skillful engineering. This page intentionally left blank. This page intentionally left blank. PROJECT NO 2009-021 1-1 MAY 2010 1.0 GEODESY & NAVIGATION Graphic A - Project area, vicinity of Ruby, AK TerraSond was contracted to establish a persistent geodetic network in the vicinity of the Ruby, AK. TerraSond was tasked with identifying the most advantageous space for repeatable measurements as well as identifying the best space for communicating the physical characteristic information regarding this survey area. TerraSond used a minimally constrained solution which included three monuments. The position of those monuments was first referenced against CORS GPS sites within an OPUS solution. The final network solution held the NGS airport monument RBY A constant while calculating a best fit solution for the newly established monuments. TerraSond indentified insignificant shift between the spatial references and ultimately migrated the positions by sub-decimeter quantities. TerraSond recovered one existing monument (RBY A) and established two new survey monuments (H-1 2009, H-2 2009). The horizontal project datum is UTM, zone 5, meters, in projection NAD83. The river elevation at the start of project was established as the project datum. All depth values in this report reference this datum, all elevations reference the WGS84 ellipsoid. The relationship of the project vertical datum is 55.000 m above the WGS84 ellipsoid. 1.1 Geodetic Network TerraSond calculated a Minimally Controlled Geodetic Network for the Ruby area. Simultaneous static GPS measurements were acquired on each monument and incorporated into the control network (H-1 2009, H-2 2009, and RBY A). The Geodetic network was measured with GPS receivers in WGS84 space and each monument was originally assigned an assumed value. PROJECT NO 2009-021 1-2 MAY 2010 The measured values were later recalculated and the assumed values were replaced with the final network calculated positions. The Minimally Controlled Geodetic Network was controlled by holding RBY A fixed as the published NGS value. The values used for H-1 2009 and H-2 2009 in the network were an average of multiple OPUS solutions. The relationships between the monuments were calculated and corrected to best conform with the static GPS measurements in order to establish the final Geodetic Network positions. 1.1.1 Monument H-1 2009 The primary monument for this project used as the base station transmitting real time kinematic (RTK) corrections is H-1 2009. H-1 2009 was used as the source for all positional RTK corrections distributed by the base station GPS receiver. H-1 2009 was located within the boundary of a public park area adjacent to the river along River Rd. Graphic B - Location of H-1 2009 Graphic C - Monument H-1 2009 WGS84 Local (m) Latitude Longitude Northing (m) Easting (m) Ellipsoid (m) Local (m) N 64° 44' 24.82019" W 155° 29' 30.75642" 7181837.428 381375.267 61.106 6.106 Description:3 1/4" Aluminum domed cap  on 3/4 rebar. Set fluch with grade. Powerline support pole  bearing N40W@9.4 ft. Cap ~19 ft N ‐ NW of road shoulder. Horizontal TerraSond Survey Monument H‐1 2009 Geodetic UTM Zone 5 (NAD83) Vertical Table One Monument H-1 2009 PROJECT NO 2009-021 1-3 MAY 2010 1.1.2 Monument H-2 2009 TerraSond established survey monument H-2 2009 in the proximity of a power pole at the tee intersection of River Rd. and Yuki St. within the Town of Ruby. Graphic D - Location of H-2 2009 Graphic E - Monument H-2 2009 WGS84 Local (m) Latitude Longitude Northing (m) Easting (m) Ellipsoid (m) Local (m) N 64° 44' 20.49927" W 155° 29' 51.94198"7181714.782 381089.959 61.184 6.184 Description:3" Aluminum domed cap on 3/4 rebar set ~0.1 ft below grade. TerraSond Survey Monument H‐2 2009 Horizontal Vertical Geodetic UTM Zone 5 (NAD83) Table Two Monument H-2 2009 PROJECT NO 2009-021 1-4 MAY 2010 1.1.3 Monument RBY A RBY A is located near the northeast portion of the Ruby Airport on the North side of the runway. Graphic F - Location of RBY A Graphic G - Monument RBY A WGS84 USGS  Latitude Longitude Northing (m) Easting (m) Ellipsoid (m) Local (m) N 64° 43' 48.85107" W 155° 27' 47.12007"7180670.994 382701.872 206.583 151.583 Description: NGS Monument RBY A Horizontal Vertical Geodetic UTM Zone 6 (NAD83) THE STATION IS A NONSTANDARD NGS 0.083 m (0.271 ft) DIAMETER BY 0.914. m (3.0 ft) LONG STAINLESS STEEL PIPE FLARED AT THE BASE. THE STATION IS LOCATED 39.2 m (128.5 ft) 206 DEGREES MAGNETIC AZIMUTH FROM A WIND SOCK, 63.1 m (207.0 ft) 166 DEGREES MAGNETIC AZIMUTH FROM THE AWAS STRUCTURE, AND 45.4 m (149.0 ft) 271 DEGREES MAGNETIC AZIMUTH FROM THE SECOND RUNWAY LIGHT SOUTHWEST OF THE TAXIWAY ON THE NORTH SIDE OF THE RUNWAY. Table Three Monument RBY A PROJECT NO 2009-021 1-5 MAY 2010 1.2 Navigation All vessel navigation was processed and distributed by Coda F-185 (F-185). The F-185 measures GPS position, heading, orientation and distributes a processed vessel trajectory. The vessel navigation and orientation was recorded in Hysweep Acquisition software during operations. Real Time Kinematic (RTK) corrections were used for vessel navigation and recorded as the positioning for all sensors utilized during this survey. This can be a more precise system of measurement than uncorrected GPS and is expected to significantly increase accuracy. This system utilizes the additional information of the carrier signal, and, when properly processed, will include the Carrier-Phase Enhancement in the final position. RTK uses the GPS satellite's carrier as its signal, not the messages contained within. The improvement possible using this signal is over a thousand times as fast as a typical GPS receiver. This corresponds to a 1% accuracy of 19 cm using the L1 signal, and 24 cm using the lower frequency L2 signal. When the two signals are correctly aligned, the generally accepted error estimation is 20 cm. RTK corrections were transmitted to the vessel navigation and recorded by the acquisition software during all survey activity. TerraSond used a temporary value for the base station location during the broadcasting of the RTK correctors. This base station value evaluated in post processing and TerraSond accounted for the migration of the measurements positions for all products distributed with this report. 1.3 Terrestrial Survey The terrestrial survey measurements were accomplished utilizing a Trimble SPS881 GPS receiver fixed to a variable-height staff. All data acquisition was accomplished while receiving RTK position corrections from the base station. The positions were evaluated and processed with Trimble Geomatics Office Ver. 1.63. A perspective modeler for the YRITWC requested that TerraSond measure the river gradient and a single transect on each bank of the river for future modeling purposes. The river gradient was measured to be 0.580 m over the river distance of 10,525 m. River elevation was measured each day with RTK corrected GPS receivers in order to measure river stage and to calculate the gradient of the river. The river level receded 40 cm (1.3 ft) over the 4 day period of MBES acquisition. PROJECT NO 2009-021 1-6 MAY 2010 Table Four List of Terrestrial Survey Points Vertical  Point Northing (m) Easting (m) Ellipsoid (m) Discription 2 3927323.99 1406381.7 61.015 H‐2 1000 3928176.01 1407836.82 54.872 WS 1001 3927836.04 1407254.5 54.869 WS 1002 3927407.85 1406353.88 54.878 WS 1003 3927400.55 1406319.2 54.775 WS 500 3927741.14 1407311.48 60.921 CHK H‐1 1004 3927844.29 1407249.61 54.641 WS 1005 3927402.79 1406319.21 54.672 WS 1006 3927374.07 1406249.51 54.653 WS 501 3927741.13 1407311.47 60.918 CHK H‐1 1007 3927846.52 1407243.48 54.489 WS 1008 3927396.67 1406293.29 54.486 WS 1009 3927376.25 1406247.23 54.489 WS 1010 3927374.53 1406244.36 54.489 WS 502 3927741.17 1407311.47 60.948 CHK H‐1 1011 3927856.38 1407243.09 54.426 WS 1012 3927393.33 1406285.56 54.413 WS 1013 3937812.94 1419639.68 54.723 WS 1014 3937806.05 1419633 54.711 WS 1015 3937824.89 1419650.45 54.705 WS 1016 3940850.43 1416962.68 54.815 WS 1017 3940852.9 1416965.17 54.799 WS 1018 3940835.41 1416953.72 54.812 WS 1019 3929869.25 1404719.67 54.395 WS 1020 3929863.89 1404720.81 54.058 H2O 1021 3929870.3 1404718.06 54.416 RND 1022 3929883.75 1404715.37 55.109 RND 1023 3929915.05 1404709.59 56.426 RND 1024 3929902.99 1404711.39 55.775 OH 1025 3929927.66 1404706.63 56.848 RND 1026 3929937.83 1404704.24 57.450 RND 1027 3929938.94 1404704.94 57.523 BRK 1028 3929937.5 1404704.23 57.331 HW 1029 3928877.38 1394363.71 54.195 WS 1030 3928875.91 1394357.24 54.164 WS 1031 3928878.48 1394379.36 54.195 WS 1032 3925607.96 1395347.45 54.173 WS 1033 3925609.52 1395357.63 54.185 WS 1034 3925609.62 1395356.7 54.191 WS 1035 3927457.76 1406744.74 62.742 PO 1036 3927541.49 1406949.89 61.982 PO 1037 3927703.96 1407307.65 62.650 PO 1038 3927312.83 1407529.36 87.584 PO 1039 3927244.75 1407059.5 77.188 PO 1040 3927111.51 1407040.05 78.845 PO 1041 3927063.2 1407054.45 78.805 PO 1042 3927143.88 1406981.66 77.939 PO 1043 3927193.23 1406964.09 77.401 PO 1044 3927154.36 1407015.42 78.979 PO 1045 3927254.61 1406815.73 71.705 PO 2000 3927779.93 1405441.2 0.000 ANCHOR 2001 3927159.77 1405725.36 61.760 J‐BOX Ruby Terrestial Survey Shots UTM zone 5 (NAD83) PROJECT NO 2009-021 2-7 MAY 2010 2.0 HYDROGRAPHY Graphic H - Bathymetric contours generated from the MBES survey TerraSond was tasked with the responsibility of acquiring, processing, and presenting remotely sensed geophysical measurements of the YRITWC Hydrokinetic Power Conversion project at Ruby, AK. The survey area included 288,301 m2 of the Yukon River. Data acquisition methodology was designed to better describe the physical character of the site for the purpose of evaluating Hydrokinetic Power Conversion, planning future development, and assessing potential hazards during development of the site. The vessel used for all operations was the Ruby Tribal Council 18 ft aluminum Jon Boat. The geophysical instrumentation deployed during this project included a pole mounted Teledyne Odom ES3 multibeam echosounder (MBES), a pole mounted Imagenix Yellowfin side scan sonar (SSS), and all navigation was recorded using positions from RTK corrected F-185 Inertial Navigation System. The mobilization crew consisted of the project Geophysicist and a Survey Technician. The vessel mobilization took place at on the shore of the Yukon River in the Village of Ruby. The Hydrographic data set includes both the Multibeam and the Side Scan Sonar products. The mapping effort of the MBES establishes the precision and accurate foundation for which the Side Scan mosaic can be draped. Both surveys were controlled through the use of RTK corrected GPS as described in Section 1.2. The precision of the MBES which utilizes a ray- tracing algorithm is far superior for across track measurements then the Side Scan Sonar which only controls the nadir position at ping transmission. For this reason, the Side Scan Sonar which presents a continuous analog record of the acoustic magnitude may have some error in the position of identified objects. Side Scan Sonar products may have been spatially shifted reasonable distances in order to match with the multibeam bathymetry. PROJECT NO 2009-021 2-8 MAY 2010 TerraSond acquired a precise high density bathymetric data set that was be used as a base DEM surface for multiple products. The project goals for the MBES data were geomorphology of the riverbed baseline, a reference surface acquired prior to development, and for numerical modeling purposes. Object detection and geologic interpretation < 2 m2 was beyond the scope of this project. Side Scan Sonar imagery was acquired for this project in order to collaborate with bathymetric data and to image the riverbed. Terrasond acquired high scan imagery of the riverbed in the southern portion of the project area. The acquisition area included a contiguous ensonification of the thalweg south to the cliff face. This is the area described by YRITWC to be the area of interest for construction of the Hydrokinetic Power Conversion project. The area of overlap between the Sides Scan Sonar and the Multibeam Echosounder defines the area that TerraSond interpreted HforC and DtoN, all areas outside this zone did not undergo the rigorous investigation for obstructions. The hydrographic data did identify objects, geologic features, and obstructions both within the area defined for interpretation as well as the area excluded from the interpretation. TerraSond produced a normalized mosaic image of the Side Scan Sonar data for an overall image of the riverbed. 2.1 Acquisition of Hydrographic data Graphic I - Teledyne Odom ES3 Multibeam Echosounder Sonar 2.1.1 Acquisition of Multibeam data The Multibeam Echosounder (MBES) calibration and acquisition of main scheme MBES data occurred May 23 - 25, 2009. TerraSond acquired bathymetric point data with Teledyne Odom ES3 Multibeam Echosounder sonar and recorded that information using HySweep Integrated Acquisition Software. An Odom Digibar Pro acoustic velocimeter was used to measure the near field speed of sound at the sonar face. An additional Odom Digibar Pro acoustic velocimeter was used to measure the speed of sound throughout the water column via manual casts performed intermittently throughout the survey effort. PROJECT NO 2009-021 2-9 MAY 2010 The MBES calibration test accounts and corrects for electronic timing errors, roll, pitch, and yaw bias. TerraSond accomplished the MBES calibration acquisition according to the industry standards. Sonar Type Teledyne Odom ES3 Sonar Operation Frequency 240Khz Beam Width, Across Track 0.75, 1.5, and 3.0 degrees Beam Width, Along Track 0.75, 1.5, and 3.0 degrees Number of Beams 120, 240, 480 Swath Coverage 120 degrees Max Ping Rate 14 Hz @ 20 m Range Multibeam Echosounder S P E C I F I C A T I O N S Table Five Technical information for the Teledyne Odom ES3 MBES TerraSond performed a calibration of the MBES using radio corrections broadcast from the H-1 2009 RTK base station over a subsurface river bed feature. The 240 kHz acoustic data was acquired parallel to the topography throughout the main scheme survey area as regular line spacing resulting in 66 main scheme survey lines. An additional 2 cross lines were recorded as part of the quality control procedure exercised by TerraSond to ensure limited directional bias in our data. This bathymetric project resulted in a full ensonification of the river bed for the area south of and including the thalweg. The area north of the thalweg was not fully ensonified and a non-overlap 50% coverage methodology was exercised. The area where infrastructure was being considered for the project development was fully ensonified and products and interpretations applicable for riverine construction were fully ensonified. The remaining cross river section was acquired only for modeling purposes, general information, and a holistic understanding of the water body. Graphic J - Preprocessed MBES Matrix as acquired in the field PROJECT NO 2009-021 2-10 MAY 2010 The southern zone was acquired with significant swath overlap which allowed for a confident interpretation of the riverbed. Sound velocity measurements were acquired at 1 Hz at the face of the MBES transducer face in order to allow for proper beam forming. Sound velocity measurements were accomplished by manual cast and measured the entire water column during MBES operations in order to ensure accurate depth measurements. Graphic K - Acquisition of Sound Velocity Profile measurement Non-systematic line acquisition was exercised in the shallow portions of the river in an attempt to achieve maximum coverage and reduce holidays (gaps) as the swath area geometry decreased. Similar strategy was used along the cliff face in order to safely approach near the cliff face without striking sub-surface obstructions. Graphic L - Navigation tower requiring innovative solutions for remote survey operations PROJECT NO 2009-021 2-11 MAY 2010 All vessel position and attitude were calculated with a Coda Octopus F-185. The F-185 consists of two GPS antenna and an inertial motion unit (IMU). The GPS antennas have a primary (L1/L2) antenna and an additional secondary antenna (L1) co-located no less than 1 m apart creating a fine baseline. The F-185 IMU was co-located on the pole arm attached to the Ruby Tribal Council vessel. The trajectory of the vessel was computed by the F-185 and recorded by the acquisition software. The RTK corrected GPS navigation was recorded and displayed in Hypack during vessel operations. The offsets and lever arms associated with the primary GPS phase center and the IMU were computed within HySweep and referenced to the CRP of survey vessel. Graphic M - Ruby Tribal Council Jon Boat as survey vessel of opportunity Offsets from CRP to Sonar Acoustic Center of the MBES were computed in Hysweep and a real-time acoustic coverage was computed and displayed for the survey crew. 2.1.2 Acquisition of Side Scan Sonar Graphic N - Imagenix Side Scan Sonar On May 26, 2009, the Ruby Tribal Council Jon Boat was mobilized for side scan sonar operations. An Imagenix Yellowfin model 372 was towed on the starboard side of the vessel. PROJECT NO 2009-021 2-12 MAY 2010 The side scan sonar acquisition frequency was 330 kHz nominal, 50 m range, resulting in an across-track resolution of 10 cm (4 in). Navigation was corrected by real-time kinematic broadcast from the H-1 2009 base station. Data was acquired using Hysweep 2009 software. Frequency (dual simultaneous)Choice of either 260 kHz / 330 kHz / 770 kHz nominal Horizontal Beam Width (HDM)260 kHz: 2.2° x 75°, 330 kHz: 1.8° x 60°, 770 kHz: 0.7° x 30° Range Resolution Range Scale/1000 Interface Analog Telemetry Towing Speed (max safe) 3 knots Towfish Material Aluminum Aluminum Maximum Operating Depth 300 m Tow Cable Type Coaxial Imagenix Yellowfin Side-Scan Sonar S P E C I F I C A T I O N S * Does not meet NOAA Shallow Water Survey Specification‐ Min 3 pings on a 1‐meter target at 100 meters range. Table Six Technical information for the Imagenix Yellowfin Side-Scan Sonar The Side Scan Sonar data was acquired parallel to the river channel geomorphology resulting in 300% coverage. Nine main scheme lines were acquired within the survey area. Cross lines were not possible due to the maneuverability of the vessel under the influence of the flow of the river and the orientation of the side scan sonar. Graphic O - Side scan sonar coverage area PROJECT NO 2009-021 2-13 MAY 2010 2.2 Hydrographic Processing TerraSond exercises a systematic methodology regarding data transfer from the field, processing, editing, and the development of hydrographic products. This rigorous protocol ensures product integrity throughout the processing path. Prior to processing, the entire field project was uploaded to our server system and included in the regular twice/day backup and daily replication scheme. The data was distributed and organized by the Processing Department prior to further development. 2.2.1 Application of Control Information On June, 5 2009, the TerraSond Survey Department in Palmer, AK received the raw Terrestrial Survey data. The Base station established on H-1 2009 utilized a temporary assumed position (based off of a preliminary Ultra-Rapid OPUS Solution) during the broadcast of GPS corrections (reference Section 1.2). For this reason all raw data acquired under RTK conditions was assumed to be inaccurate as recorded by the acquisition software once the geodetic network reference space was established. This methodology is a commonly practiced technique and resulted in no loss of final processed data precision. The associated navigational error was consistent, systematic, and recoverable. All survey records require the assumed position error to be compensated for through a global position shift for all points measured. The temporary horizontal (WGS84) and vertical (WGS84) position was shifted from the temporary assumed space measurement to the processed network position computed by TerraSond. The 3-dimensional shift was applied to the terrestrial survey in Trimble Geomatics Office suite. The vertical position for each point in the Bathymetric DEM surface was adjusted in Caris HIPS. The Horizontal shift for each point in the Bathymetric DEM surface was accomplished in Trimble Terramodel. The Acoustic Intensity Mosaic image was shifted using Chesapeake Technologies SonarWiz. Ultimately, precise ephemeris calculated a trivial variation for the H-1 2009 monument from the Ultra-Rapid OPUS solution used to record the data for this project. The value for the data migration was within the allowable error for our measurement systems. For this reason, no migration of the MBES, SSS, or ADCP data was necessary for this project. 2.2.2 Multibeam Echosounder Processing The MBES calibration (commonly called a “Patch Test”) acquired on May 23, 2009 was processed for the identification of temporal latency and MBES orientation errors. This effort was accomplished using the Caris HIPS and SIPS calibration tool and the correction values were entered into vessel configuration file for CARIS Hydrographic Information Processing System (HIPS) version 6.1. PROJECT NO 2009-021 2-14 MAY 2010 On June 5, 2009, the TerraSond Processing Department in Palmer, AK received the raw MBES data and associated acquisition records for final processing. HIPS version 6.1 was used for all data processing and adjustments necessary to produce final bathymetric products. The Caris HIPS workflow is designed to ensure that all edits and corrections made to the raw data, and all computations performed with the data followed a specific order and were saved separately from the raw data to maintain the integrity of the raw acquisition data. TerraSond uses well defined procedures during HIPS processing; all actions are tracked to ensure that no steps are omitted or performed out of sequence. 2.2.3 Vessel Editor The first component of the HIPS processing workflow requires establishment of a framework in which recorded navigation, vessel motion, raw (unprocessed) depths and vessel draft are referenced to a common position. The HIPS Vessel Editor is an application used for viewing and editing the position and calibration of sensors installed on the vessel. This information is stored in the HIPS Vessel File (HVF). The HVF is divided into a number of distinct sections, each describing one type of sensor. The sections are time-tagged and multiple entries can be defined for different time periods. The HVF is based on a three-dimensional coordinate system which locates equipment within an X-Y-Z axis using a reference point on the vessel as the point of origin. The reference point for this survey is co-located with the motion sensor which is installed at the vessel’s approximate center of gravity; the point at which the least amount of motion is experienced. The position of the multibeam echosounder transducer as well as the static draft (waterline) of the vessel is recorded in the HVF with respect to the reference point. Static draft values were measured on a daily basis for entry in the HVF to track changes in vessel draft caused by loading and fuel consumption. During data acquisition, RTK GPS positioning was referenced from the X-Y-Z coordinate of the GPS antenna phase center to the motion sensor within the vessel coordinate system. All recorded navigation data is referenced to the RP. Therefore, the X-Y-Z coordinates of the GPS antenna phase center need not be entered in the HVF. 2.2.4 Raw Data Conversion CARIS HIPS was used to create a folder structure organized by the project, vessel, and Julian day to store data. Raw MBES data was converted from its native Hypack format, *.hsx files, into CARIS HIPS using the CARIS conversion wizard module. The wizard was used to create a directory for each line separating the *.hsx files into sub-files which contain individual sensor information. All data entries were referenced using the time associated with the *.hsx file to relate the navigation, azimuth, heave, pitch, roll, and slant range sensor files. 2.2.5 Navigation Editor Navigation data was reviewed using the CARIS Navigation Editor. The review consists of a visual inspection of plotted fixes noting any navigation gaps in the data. Additionally, vessel speed, distance between navigation fixes and course made good are examined for anomalies. If PROJECT NO 2009-021 2-15 MAY 2010 any anomalies are detected, the processor may choose to reject or interpolate the affected areas. The data in this project displayed no anomalies with respect to navigation. 2.2.6 Attitude Editor Attitude data was reviewed using the HIPS Attitude Editor. The review consists of a visual inspection of the heave, pitch, roll and GPS (ellipsoidal) height which are displayed simultaneously in a graphical representation using a common x-axis scaled by time. The Attitude Editor, like the Navigation Editor, is used to identify anomalies and has the ability to interpolate or reject the affected areas. The data in this project displayed no anomalies with respect to attitude. 2.2.7 Sound Velocity Editor Each sound velocity profile, or cast, was examined using the HIPS Sound Velocity Editor for potential outliers prior to its application in HIPS. Erroneous sound velocity changes will cause a concave or convex distribution of soundings. This artifact is caused by the sound velocity correction required for the outer beam forming computation. The data in this project displayed no anomalies with respect to sound velocity. The sound speed adjustment in HIPS uses slant range data, applies motion correctors to determine launch angles, and adjusts for range and ray-bending resulting in a sound speed- corrected observed-depths file. It is recommended that sound velocity correction be executed before cleaning the data. 2.2.8 GPS Tide Computation and Merge Upon review of navigation, attitude, and sound velocity, the vessel positioning was converted from local datum heights to water level and subsequently to the final project datum. In our case, the tide and GPS tide was the variation of the vessel vertical motion from the position of the base station offset. These processes are referred to as the computation of GPS Tide and Merge. The full formula for GPS Tide is shown below. GPS Tide = GPS (ellipsoidal) Height - Datum Height - Heave - Waterline Offset Where: • GPS height = RTK ellipsoidal heights referenced to the vessel RP • Heave = time-tagged measurements of the vessel’s vertical motion recorded by the motion sensor and referenced to the vessel RP • Waterline offset = time-tagged waterline levels referenced to the vessel RP and measured daily by the Hydrographer PROJECT NO 2009-021 2-16 MAY 2010 • Datum Height: The distance from the ellipsoid to project datum (USGS Stream Gage Datum). Once post-processing of the static GPS network was completed (as described in Section 1.1), a trivial value of 0.007 mm was calculated as the shift from assumed position to the post processed geodetic network height. An additional and cumulative shift of 55.001 m was applied to bring the surface from WGS84 Ellipsoid to the local river surface datum. Finally, the HIPS Merge process was conducted on the dataset. Merge is the process of calculating final positions and depths for soundings, based on all relevant inputs such as observed depths, navigation information, vessel dynamics such as gyro, heave, pitch and roll, and tide. 2.2.9 Subset Editor Following final processing and quality assurance of draft and GPS tide applications, several area-based editing processes in CARIS HIPS Subset Editor were performed during the office review of survey soundings. During subset editing (cleaning), the processor was presented with two and three-dimensional views of the soundings and a moveable bounding box to restrict the number of soundings being reviewed. Using the two-dimensional window, soundings were viewed from the south (looking north), from the west (looking east) and in plan view (looking down). These perspectives, as well as controlling the size and position of the bounding box, allowed the operator to compare lines, view features from different angles, measure features, query soundings and change sounding status flags. Soundings were also examined in the three-dimensional window that could be rotated on any plane. Vertical exaggeration was increased as required to amplify trends or features. While HIPS does not allow for the deletion of any sounding, spurious soundings (noise) were flagged as rejected during subset editing. Soundings flagged as rejected are excluded from any final bathymetric product. 2.2.10 Caris BASE Surfaces The CARIS HIPS Bathymetry Associated with Statistical Error (BASE) Surface is a 3D, georeferenced image of a multi-attributed, digital terrain model. To build a BASE surface, HIPS assigns a set of gridded nodes at user-defined spacing and bounding coordinates. Each grid node is assigned a depth value based on nearby sounding values. All BASE Surfaces use range weighting to determine how a sounding is applied to a node. Range weighting is based on distance; soundings close to a node are given greater weight than soundings further away. Additionally, all BASE surfaces created for this project use a weighting scheme based on a beam’s intersection with the river bed; soundings formed by the outer beams are weighted less in the algorithm than more reliable nadir beams. BASE surfaces can be used to identify areas requiring further cleaning as well as comprise the final bathymetric product. Once the sounding dataset was cleaned and all corrections were applied, a 1.0 meter resolution BASE surface was created for use in development of bathymetric products. Points identified to be the shoal point of an object above the ambient river bed interpreted to be rocks or other anomalous features were designated, exported, and appended to the gridded DEM surface in order to minimize the height attenuation of obstructions common to surface generation. PROJECT NO 2009-021 2-17 MAY 2010 2.2.11 Processing of Side Scan Sonar All main scheme lines were processed and evaluated for Danger to Navigation and Hazard for Construction obstructions. Select lines were used during mosaic production based upon aesthetic qualities and the needs of interpretation. The software used to process this data was Chesapeake Technologies SonarWiz Map 4.04.0052 (SonarWiz). SonarWiz.MAP software was used to create a folder structure organized by Julian day to store data. Side scan raw data (.hsx) files were imported into SonarWiz.MAP using the SonarWiz.MAP Import Side Scan Files function, which converted the sonar files into SonarWiz.MAP compatible *.csf format. SonarWiz.MAP does not permit raw data manipulation during processing. All raw data is maintained in the original, unmodified, format to ensure data integrity. TerraSond uses well defined procedures during side scan data processing and all actions are tracked to ensure that no steps are omitted or performed out of sequence. After conversion, vessel navigation data was visually evaluated for inconsistent, erratic, or unrealistic changes in speed, distance, and course made good. The side scan lines were opened in the SonarWiz.MAP Bottom Track Editor where towfish altitude was manually digitized; this is the process of digitizing the floor or removing the water column from the record. The final process applied to the side scan sonar data was the application of XY offsets to represent the tow point with respect to the central reference point (CRP) of the vessel to correctly position the data geographically. The side scan record was carefully examined for significant obstructions and classified as contacts in the slant-range corrected record. Significant contacts included, but were not limited to, contacts with a shadow length indicating a contact height of 1.0 m or greater. Contacts were digitized using the contact tool in SonarWiz.MAP Side Scan Digitizer View. Each contact was automatically assigned a unique identifier based on the date, time, and channel (port or starboard). Once identified, the contact’s length and width were measured with the Measure Length and Measure Width tools and the contact shadow length was measured using the Measure Shadow tool. SonarWiz.MAP automatically calculates contact height once the shadow length is measured. SonarWiz.MAP generated an image of each digitized target and included a corresponding text file containing all recorded information specific to the contact and placed the contact in the project folder. Contacts were then exported as targets to an ESRI shape file. This information was then spatially referenced with MBES data for evaluation and reporting. The product of target classification was obstacle detection, identification, and positioning in the form of an Obstruction List. Select lines with the best representation of river bed coverage and meaningful albedo were selected to contribute to the acoustic intensity mosaic image. PROJECT NO 2009-021 2-18 MAY 2010 2.3 Hydrographic Products While the HIPS workflow allows for application of vertical changes in order to perform datum transformations and adjustments, the software does not allow for horizontal migration. The horizontal projection of the dataset is UTM, NAD83, Zone 5 and all soundings are vertically referenced to local river height during 11,300 m³/s discharge conditions. All units are expressed in meters. The horizontal shift of the mosaic and the bathymetric MBES surface (DEM) by the processed Geodetic Network space correction factor was the final processing step in the processing flow. 2.3.1 Bathymetric DEM gridded dataset and imagery The regular gridded Digital Elevation Model surface is a critical product. This surface is the foundation for all charting and positioning, and it is the reference surface for the obstruction list as well as the Side Scan Sonar deliverables. This surface was considered in each interpretation and during the generation of all location positions. The sole origin for this digital DEM is the Multibeam Echosounder point file. The high density data from the MBES is often too large to manage by most software suites. TerraSond reduces the data through the process of surface generation in Caris HIPS software. The number of points in the original post processed and post edited surface that was used to generate the DEM was 32,002,560 points. The number of points in the final DEM product distributed with this report is 695,113 points (produced as a regular grid with 1m resolution). There is a small loss of detail that develops as we reduce the data that makes up the surface of the DEM product. This loss is directly related to the node spacing established in the final surface. The exact location of loss is not known nor controlled. During regular gridding, TerraSond will not have control of the data that is reduced. We will not be able to confirm that the most shoal depth of an obstruction is the exported grid point nor if it is properly represented in the DEM. For this reason all values for shoal height are conservative and were exported as a shoal biased grid. For the reasons stated above, we cannot verify more vertical precision in the DEM obstructions depths finer than sub meter precision. The horizontal precision is accurate to 1.0 m and obstruction identification resolution is 2 m3. The DEM surface was generated from referencing a maximum footprint size 5x5 grid cells with a minimum of 6 nearest neighbors. The DEM product grid spacing was 1.0 meter distance. This surface was interpolated in order to maintain the high level of detail necessary for obstruction detection and interpretation. TerraSond filled the holidays present in the 1.0 m surface grid with information by applying a Triangular Interpolated Network function contained in the Caris processing software. This process allowed for the generation of a contiguous image. PROJECT NO 2009-021 2-19 MAY 2010 This process was particularly vital for the northern portion of the MBES information, however, several trivial holidays were identified in the post processing data after the editing of the data had been accomplished. The geodetics for the output file are UTM zone 5 projected as NAD83 and the units are meters for the horizontal dimension. The vertical dimension (positive axis up) is also in units of meters and is based upon the datum of the Yukon River stage at the start of project (11,300 m³/s discharge). This surface was included in the Fledermaus Digital Product bundle and distributed on both the TerraSond FTP site and included in the DVD data distribution which accompanies this report. Two images with different color scales have been generated from this DEM. Both are the same except for the inclusion of the color purple in the spectrum. All images which do not include the purple in the color scale spectrum are suitable visualization with common 3D glasses for an enhanced visualization and interpretation by the viewer. The files that included purple in the color scale spectrum are intended for finer differentiation of depth and digital distributions, but do not visualize well through 3D glasses. PROJECT NO 2009-021 2-20 MAY 2010 Graphic P - Image of Bathymetric Surface (scaled by depth) PROJECT NO 2009-021 2-21 MAY 2010 2.3.2 Acoustic Intensity Mosaic The Acoustic Intensity Mosaic is a compilation of selected Side Scan Sonar lines which best visualize the riverbed spatially and through the albedo spectrum. The lines are assembled as a stack of linear image files processed with Automatic Gain Control algorithm. The compilation was digitally compiled in SonarWiz.MAP and the seams were digitally muted through the cover- up software option. There are lineations in the mosaic which can be attributed to the image boundaries and should be recognized as artifacts of the images when viewing this mosaic. Two sources of lineation artifacts are present in the mosaic; image boundaries and nadir stitching. Graphic Q - Acoustic Intensity Mosaic Image PROJECT NO 2009-021 2-22 MAY 2010 TerraSond used the products from each geophysical sensor to production interpretations of the physical characteristics of the Yukon River and the Riverbed within the project site. These interpretations enabled TerraSond to make educated recommendations to the YRITWC about the project site when planning for the installation and deployment of the Hydrokinetic Instream Turbine. TerraSond evaluated the geomorphology of the alveus, albedo of the side scan intensities, analyzed the moving bottom information, and referenced the current flow regime when interpreting the geologic substructure needed for the deployment of the 2009 Turbine Anchors. Graphic R - Geologic Interpretation of the Riverbed near the project site 2.3.3 Hazard for Construction and Danger to Navigation List TerraSond referenced the side scan sonar imagery of the river bed for obstruction targets. These targets were processed and recorded in Chesapeake SonarWiz Software and displayed in ESRI ArcMap for correlation with other geophysical sensor data. Classification of the targets was beyond the scope of the project. All obstructions are assumed to be naturally occurring and TerraSond recommends avoidance as the coping strategy. The Obstruction Target List is a composite table from multiple surveys and the interpretation of obstructions from those data. The terminology of the obstructions list is not consistent with the terminology found in NOS Hydrographic Surveys Specifications and Deliverables, NOAA, Dept. of Commerce, 2009. The criteria were modified by the Project Hydrographer to a more stringent project specific standard. One criterion stated in the NOS Hydrographic Surveys Specifications and Deliverables regarding Danger to Navigation is stated as: “Depths from the present survey which are found to be significantly shoaler then the charted depths or features, and are navigationally significant (typically depths of 11 fathoms (fms) (66ft) or less).” PROJECT NO 2009-021 2-23 MAY 2010 A typical standard for obstruction interpretation for navigation charting is: “1.0 m proud of the seafloor in depths < 11 fms or 10% of depth in depths >11 fms” The standard used for this project only considered the project area from the thalweg south to the cliff shore (left bank). Obstructions were identified in the more northern zone, however, complete coverage was not obtained through the sonar activity and TerraSond could not clear any portion of that northern zone for DtoN and HforC. TerraSond recommends that the entire zone north of the thalweg be treated as uncharted and to contain Dangers to Navigation and Hazards for Construction. Graphic S - Charted vs. Uncharted boundary for Dangers and Hazards The specific criteria used to classify and differentiate between Danger to Navigation and Hazard for Construction obstructions were not easily determined for this project area. Typically, for Alaskan Rivers, the United States Geologic Survey (USGS) has established a well documented yearly average for a river and TerraSond references that information when assessing the probability of a vessel encountering an obstruction under the river surface. That information was not available without a direct tie to the historic USGS activity datum for the project area in Ruby. TerraSond estimated that the water level for the 2009 Survey event was accomplished as a high water event as depicted in Graphic T. The expectation is that the water level will drop significantly at various times during the summer season. TerraSond allowed for a 3 m drop in river stage at the Ruby site to define a low flow water line level. TerraSond estimated an additional maximum keel depth of 4m for river traffic. The distinction depth between a designation of Danger to Navigation is any obstruction within 7 m depth of the project datum. PROJECT NO 2009-021 2-24 MAY 2010 Any obstruction below that datum has been classified as a Hazard for Construction and does not necessarily need to be avoided during vessel operations. Graphic T - Average discharge behavior on the Yukon River (Water-Resources Investigations Report 99-4204) The criteria used for obstruction classification for this project: Obstructions 1.0 m proud of the seafloor in depths < 7 m are classified as Dangers to Navigation. The obstructions 1.0 m proud of the seafloor in depths > 7 m are classified as Hazards for Construction. The Obstruction List is a combination of targets and contacts identified in data from: • Multibeam Echosounder Sonar Survey • Side Scan Sonar Survey PROJECT NO 2009-021 2-25 MAY 2010 Contact ID SSS Target Discovery Northing m Easting m Latitude Longitude Depth m Hazard Classification Volume m3 Description HfoC 01 4 197-0459 Sidescan 7181713.2489 380793.9078 64.7389090 -155.5039720 N/A Hazard for Construction N/A Obstruction Area, Possible Rocks. HforC 02 7 197-0459 Sidescan 7181724.2906 380790.8509 64.7390070 -155.5040450 N/A Hazard for Construction N/A Obstruction Area, Possible Rocks. HforC 03 1 192_0452 Sidescan 7181717.0469 380789.4413 64.7389600 -155.5040000 N/A Hazard for Construction N/A Obstruction Area, Possible Rocks. HforC 04 2 187-0445 Sidescan 7181757.7917 380860.1978 64.7393318 -155.5026180 N/A Hazard for Construction N/A Obstruction HforC 05 Not Seen in SSS Multibeam 7181704.4730 380706.8500 64.7387994 -155.5057911 8.003 Hazard for Construction 21.784 Obstruction HforC 06 1 197-0459 Both 7181714.2170 380786.0750 64.7389148 -155.5041370 8.346 Hazard for Construction 2.434 Obstruction Area, Possible Rocks. HforC07 2 197-0459 Both 7181725.0870 380784.1810 64.7390116 -155.5041858 9.511 Hazard for Construction 6.202 Obstruction Area, Possible Rocks. DtoN 08 Not Seen in SSS Multibeam 7181730.1780 380934.3220 64.7391104 -155.5010398 6.861 Danger to Navigation 1.206 Obstruction HforC 09 3 192_0452 Both 7181732.9260 380732.7420 64.7390636 -155.5052715 10.230 Hazard for Construction 3.214 Obstruction HforC 10 Not Seen in SSS Multibeam 7181743.8230 380772.3240 64.7391754 -155.5044501 10.197 Hazard for Construction 6.078 Obstruction HforC 11 Not Seen in SSS Multibeam 7181746.3170 380957.5900 64.7392634 -155.5005650 8.074 Hazard for Construction 1.897 Obstruction HforC 12 6 197-0459 Both 7181748.3150 380899.5630 64.7392607 -155.5017841 10.295 Hazard for Construction 2.586 Possibly sandbags HforC 13 Not Seen in SSS Multibeam 7181757.8730 380795.8600 64.7393097 -155.5039679 9.822 Hazard for Construction 5.748 Obstruction HforC 14 Not Seen in SSS Multibeam 7181763.3510 380848.3740 64.7393774 -155.5028706 11.572 Hazard for Construction 1.335 Obstruction HforC 15 Not Seen in SSS Multibeam 7181790.9450 380642.6800 64.7395518 -155.5072093 11.049 Hazard for Construction 7.084 Obstruction HforC 16 Not Seen in SSS Multibeam 7181792.4560 380890.4640 64.7396532 -155.5020117 10.785 Hazard for Construction 14.151 Obstruction HforC 17 Not Seen in SSS Multibeam 7181736.2390 380762.5600 64.7391039 -155.5046487 10.742 Hazard for Construction 1.704 Obstruction HforC 18 Not Seen in SSS Multibeam 7181732.7250 380761.7110 64.7390721 -155.5046635 10.546 Hazard for Construction 3.266 Obstruction DtoN 19 3 197-0459 Both 7181710.5200 380792.2940 64.7388839 -155.5040034 6.732 Danger to Navigation 16.947 Obstruction Area, Possible Rocks. DtoN 20 Not Seen in SSS Multibeam 7181708.0190 380791.8540 64.7388613 -155.5040106 6.063 Danger to Navigation 29.419 Obstruction Area, Possible Rocks. DtoN 21 5 197-0459 Both 7181709.4950 380803.0180 64.7388785 -155.5037776 5.693 Danger to Navigation 13.711 Obstruction Area, Possible Rocks. DtoN 22 Part of large outcrop Both 7181704.7650 380800.7610 64.7388353 -155.5038210 5.185 Danger to Navigation 247.430 Obstruction Area, Possible Rocks. Obstruction List Table Seven List of Obstructions interpreted from the MBES and SSS data sets Graphic U - Obstruction locations over project area Graphic V - Zone of Avoidance due to Danger to Navigation obstructions in the vicinity of the 2008 deployment site PROJECT NO 2009-021 2-26 MAY 2010 2.4 Important note TerraSond understands that the information gathered for this project is intended to facilitate the planning of river construction projects and that our data may contribute to safe river operations. This data is not to be used for navigational purposes. This data should not be used to replace any publication distributed by NOAA or the Department of Transportation nor does TerraSond assume any responsibility for safe navigation or safe marine operations. The distributions of any obstruction data recorded during May, 2009 may or may not contain valuable information regarding vessel navigation. For that reason, TerraSond recommends avoiding contact locations where navigation may be at risk, but does not guarantee that additional unobserved or uninterpreted hazards are within the boundaries of this project. TerraSond does not guarantee that interpreted obstructions are persistent or that potential obstructions will be present at a future date. Natural/manmade hazards in this project area are dynamic and are known to be spatially transitory. The use of products provided by TerraSond is only valid for the moment of acquisition and all forecasts, assumptions, or logical conclusions are wholly the responsibility of the user. The use of such products in conjunction with the products of agencies which are responsible for safe navigation (i.e. NOAA, DOT, USACE, USCG, etc.) is highly recommended. PROJECT NO 2009-021 3-27 MAY 2010 3.0 HYDROKINETICS Graphic W - ADCP Transect lines for current velocity measurements across the Yukon River TerraSond was tasked with the responsibility of acquiring, processing, and presenting remotely sensed hydrokinetic measurements at the YRITWC Hydrokinetic Power Conversion Project Site at Ruby, AK. The survey area included seven transect sites across the Yukon River. TerraSond selected a primary line (Line D) in the vicinity of the historical 2008 turbine deployment site and planned three additional lines upriver and three lines down river 45.75 m (150 ft) distance apart. Two types of data were gathered to better describe the hydrokinetic character of the river for the purpose of evaluating Hydrokinetic Power Conversion. The primary line (0 m offset), Line D, was used to measure the discharge. All lines were measured with the intention of evaluating the across profile current velocity and flow regime. Terrestrial survey extension of the primary transect continued up onto the shore in order to enable future modeling of the channel under various water levels. The vessel used for all operations was the Ruby Tribal Council Jon Boat after it was measured as a survey vessel of opportunity. The geophysical instrument deployed during this project included a pole mounted Teledyne RDI 1200kHz Sentinel Workhorse Acoustic Doppler Current Profiler (ADCP). All navigation was distributed as RTK corrected from a Trimble SPS881GPS Receiver and heading was distributed by the Coda Octopus F-185 Inertial Navigation System. PROJECT NO 2009-021 3-28 MAY 2010 The mobilization crew consisted of a Geophysicist and a Survey Technician. The vessel mobilization took place on the Yukon River bank. On May 22, 2009, TerraSond acquired QAQC files measuring moving bed and magnetic heading calibrations. The heading required an offset of 17.59° (between GPS and ADCP orientation) and the moving bed test was positive. Graphic X - Ship track line from the ADCP referencing both the geodetic navigation and the bottom tracking navigation Graphic above demonstrates the moving bottom impact in the thalweg portion of the river during the record of an ADCP transect. Both the south (left) shore and the north (right) shore have slower river current speeds and the riverbed does not demonstrate a rate of change from the geodetic navigation. Only in the thalweg does the data reveal deviation from the geodetic transect. This information was acquired for reference of future modeling efforts and in order to support future sediment transport studies. 3.1 Acquisition and processing of Discharge Measurement TerraSond acquired four transect measurements along the Primary Transect Line (Line D) in compliance with USGS methodology for discharge measurements using ADCP sensors. All measurements were within acceptable tolerance. The software used to acquire and compute the discharge measurement was WinRiver II. The four transects measured by TerraSond to be used for the discharge computation had a standard deviation of 1.94%. The discharge value computed by WinRiver II from those measurements reported a Total Q of 11,334.58 m3/s. TerraSond referenced published data in order to verify our measurements while in the field. PROJECT NO 2009-021 3-29 MAY 2010 Station Number: 0 Station Name: YRITWC Party: DSO, ZM Boat/Motor: Gage Height: 0.000 m Area Method: Avg. Course Nav. Method: DGPS MagVar Method: Model (0.0°) Depth Sounder: Not Used Performed Diag. Test: YES Performed Moving Bed Test: NO (recorded in a different file) Performed Compass Test: NO (recorded in a different file) Meas. Location: Ruby, AK Width: 843.8 m Area: 7697.7 m² G.H.Change: 0.000 m ADCP Depth: 0.152 m Shore Ens.:10 Bottom Est: Power (0.1667) Top Est: Power (0.1667) Meas. No: 1 Date: 05/22/2009 Processed by: DSO Mean Velocity: 1.47 m/s Discharge: 11,300 m³/s Index Vel.: 0.00 m/s Rating No.: 1 Project Name: ruby_test_0-0degmagtrian.mmt Software: 2.05 Screening Thresholds: BT 3-Beam Solution: YES Max. Vel.: 2.84 m/s Type/Freq.: Broadband/1200 kHz WT 3-Beam Solution: NO Max. Depth: 13.8 m Serial #: Firmware: 51.35 BT Error Vel.: 0.10 m/s Mean Depth: 9.12 m Bin Size: 25 cm Blank: 50 cm WT Error Vel.: 1.07 m/s* % Meas.: 82.27 BT Mode: 5 BT Pings: 1 BT Up Vel.: 0.30 m/s* Water Temp.: None WT Mode: 1 WT Pings: 1 WT Up Vel.: 2.57 m/s* ADCP Temp.: 7.4 °C WV : 254 Use Weighted Mean Depth: YES 3.2 Acquisition and processing of Current Magnitude Imagery TerraSond acquired a single transect across the river at 7 locations throughout the project site at intervals of 45.75 m. This data was intended to display the flow distribution and help characterize the flow behavior. The data was processed while in the field and evaluated to target turbine candidate sites (reference section 4.0). PROJECT NO 2009-021 3-30 MAY 2010 The current measurements were acquired while under vessel power and velocity standards maintained vessel at course made good < 50% of the river current velocity. Heading was distributed by the Coda F-185 while the navigation was distributed by Trimble SPS881 corrected by RTK radio signal. Bottom tracking was acquired to help correlate with bathymetry and allow for alternative navigation comparisons. The extent of each transect was limited by the river bank slope. Of particular note, the north (right) bank had a very gentle slope and limited the length of each measurement as we approached the right shore. Each transect measured the current velocity across as much of the alveus as possible and captured the entire thalweg. The processing of the ADCP transect information was initially filtered in WinRiver II software. The current magnitude presentation was later processed with MATLab numerical processing software at the TerraSond Processing Center in Palmer, AK. The products presented in this report have a horizontal three cell moving average applied to the data. Graphic Y - Current Magnitude for Transect G illustrating the current distribution across the alveus This transect is a good representation of the characteristic flow behavior in the Yukon River at Ruby. The thalweg is interpreted to hold a heavy concentration of the river’s power and the flow distribution is mostly contiguous and predictable with river bed geomorphology. The peak flow is focused at the range of 300 m from the start of line near the cliff which makes up the left shore. PROJECT NO 2009-021 4-31 MAY 2010 4.0 PLANNING INFRASTRUCTURE DEVELOPMENT The primary goal for this project was to help identify candidate sites for the deployment of the YRITWC hydrokinetic turbine. After the acquisition of the geophysical data, but while still in the field, TerraSond presented minimally processed products to YRITWC project manager for resources assessment. The primary consideration was where was the nearest persistent high energy current regime to the junction box. Graphic Z - Processed current magnitude images for the nearest three transects to the Power Junction Box TerraSond interpreted the river to have a significant zone of reduced velocity in the zone nearest to the Junction Box. As the flow of the river approaches the cliff face a zone of resistant flow is encountered in the river which slows the near shore current at the left bank. This zone experiences two conflicting forces, first originates from a small tributary effluent just upriver of the cliff face, and the second is the impact with that constriction point of the cliff structure. The cliff is acts as a significant redirection, and Line B (of the lines measured) is a very good example of current attenuation at the left bank. The river rebounds and quickly and recovers from the left bank retardation of the current force as is presented in the Graphic Z presentation. Graphic AA - Processed current magnitude for Line A as it flows into the project area of interest PROJECT NO 2009-021 4-32 MAY 2010 In Graphics Z and AA, the highest energy can be found in the 300 to 400 m range across the river. The YRITWC was not targeting this zone for the placement of the 2009 turbine deployment. This zone was perceived to have significant river use conflicts and the highest energy zone was a possible hazard for the turbine infrastructure. TerraSond was directed to target energy sources of 2.0 m/s or higher which were persistent and near the Junction Box Infrastructure and outside of the primary traffic areas for vessel transit. Although the 2.0 m/s surface current contour was expected to migrate with river stage, TerraSond’s interpretation of the river dynamic was that the upriver portion of this compression zone be highly mobile and would be strongly dependent upon river stage. The down river portion of the compression zone would infill with a more predictable consistent contour due to the dispersed flow. TerraSond used the discharge measurements to develop a description of the persistence for the 2.0 m/s contour along Primary ADCP transect line (Line D). This analysis of the persistence of the surface flow was disappointing; there was a significant laterally migration range between the 2.0m/s contour along this line even with consistent discharge. Terrasond selected a target turbine site that was consistently at 2.0 m/s contour. The location for the Turbine Site A was selected to be located at N 64° 44’ 24.5527”, W 155° 30’ 16.1235” and the riverbed site for the Sandbag Anchor deployment was selected to be located at N 64° 44’ 24.8239”, W 155° 30’ 14.0574”. PROJECT NO 2009-021 4-33 MAY 2010 Graphic BB - Original choice for 2009 Turbine Site A while in the field TerraSond participated in the deployment of the Sandbag Anchor and establishing the Debris Diversion Device on that anchor system. TerraSond provided vessel piloting and navigation services to the YRITWC during these operations. The hydrokinetic turbine was not installed while TerraSond personnel were on site. TerraSond was notified in the July, 2009 that the Turbine Site A location was outside of the radius of the power cable infrastructure available to YRITWC project .TerraSond was asked to reevaluate data for an equivalent site more near the Power Junction Box. No equivalent site was identified within the radius constraints of the power cable, however, 2009 Turbine Site B was selected based upon the processed data from the May expedition. The power difference between Site A and Site B was ~ 0.20 m/s velocity reduction (from ~2.1 m/s to ~1.9 m\s).The 2009 Turbine Site B was placed 153 m along ADCP Line C from the start of line. The location was 180m from the Electrical Junction Box (2D distance). Graphic CC - Processed Bathymetry showing locations of infrastructure positions The 2009 Turbine site was selected upon the power potential and the vicinity from the junction box, however, this site also needed to be acceptable for the placement of riverine anchors. The YRITWC requested an analysis of the river that would be adequate for two large concrete anchors. YRITWC provided TerraSond with the length of sub-river tether from the anchor to the turbine barge. TerraSond referenced the HforC and the DtoN list for obstructions in the vicinity of the anchor proposed locations. TerraSond identified that the geologic substrate for both the Left and the right anchor location was solid rock separated by acoustically absorptive PROJECT NO 2009-021 4-34 MAY 2010 unconsolidated sediment. A slope analysis was conducted over the proposed anchor sites and both locations demonstrated slope < 5%. Graphic DD - Slope Analysis with Anchor Sites and Zone of Caution Graphic EE - Image from the Fledermaus Presentation for the profile demonstrated in Graphic CC TerraSond computed the positions for each anchor location as would be referenced from a GPS antenna on the bridge of the barge vessel that was intended to deploy the anchors and distributed those positions to the YRITWC along with a series of maps and charts for reference. TerraSond assembled the information from this project into a static model for YRITWC in order to help facilitate project planning and as a communication device for the public. This model is presented as a Digital 3D presentation in Fledermaus and IView4D. This work has also been PROJECT NO 2009-021 4-35 MAY 2010 translated into Google Earth Files and is available in that medium for presentation and dissemination. Graphic FF - Drawing of the TerraSond recommendation for positioning of the anchors and turbine Graphic GG - Image from ESRI Presentation for the river including general geomorphology PROJECT NO 2009-021 4-36 MAY 2010 This page intentionally left blank. PROJECT NO 2009-021 5-37 MAY 2010 5.0 CONCLUSIONS AND RECOMMENDATIONS TerraSond believes that the Yukon River Inter-Tribal Watershed Council (YRITWC) In-river Hydrokinetic Power Conversion Proof-of-Concept Project at Ruby has significant potential to produce seasonal power for the community through contribution to the existing power grid infrastructure. Not only has the development of this project lead the nation’s effort to include non-traditional hydrokinetic power conversation into existing power infrastructure, but the YRITWC has exercised significant discipline in accomplishing this installation utilizing only readily accessible equipment available to isolated village populations. This project has mastered many of the challenges associated with deploying the hydrokinetic power conversion technology in remote Alaskan communities. Onsite innovation, overcoming infield problems, and experiencing the tribulations of this project has the YRITWC informed the remaining hydrokinetic community for future projects of this nature. This effort has displayed an opportunity for the vibrant hydrokinetic community of Alaska to observe, appreciate, and avoid future issues when dealing with the natural river systems and remote locations similar to Ruby, AK. The success of this project and dynamic understanding of the resource available for power generation has not yet been fully described nor quantified. Much of the necessary data accomplished during the 2009 data acquisition effort described in this report was accomplished with the effort described in this report in mind. A significant effort remains to be accomplished in the form of products which will describe and quantify the potential for hydrokinetic conversion opportunity at Ruby. The project described within this report accomplished the primary goal; the acquisition, processing and interpretation necessary to best site a surface mounted turbine with connection to the Ruby power infrastructure. During the 2009 effort, TerraSond acquired information that was intended to be used to inform a Kinetic Flow Model of the Yukon River resource. This modeling exercise was intended to be applicable beyond the measurement event of the acquisition survey. The information that can be extracted from existing data for this purpose is: • Riverbed Roughage • Geomorphology (Bathymetry and DEM) • Discrete Current Measurements • Riverbank Transect • River Gradient All measurements are associated with a specific River Discharge In addition to the discrete current measurements accomplished during the project described in this report, TerraSond is aware of a long term current velocity record of the entire water column at the Turbine site (acquired during much of the 2009 field season). TerraSond recommends continuing this effort through 2010 in order to capture an entire season’s energy measurement. PROJECT NO 2009-021 5-38 MAY 2010 TerraSond recommends the processing of this a power record for both seasons in order to quantify the velocity information, and ultimately, the natural power potential for the project site. TerraSond believes that the resource potential for the 2009 and 2010 field season could be processed and used to model the Yukon behavior under a diverse range of model conditions. A comparison of the natural resource with the electric power production that is available to the community grid at Ruby has yet to be accomplished. The continuation of the measurement described above would be a component in this comparison This effort would require a simultaneous measurement of the resource in phase (as described in the previous paragraph) with the electric power-received record. TerraSond understands that this goal was attempted during the field season of 2009, however, cable transmission integrity issues developed in this unique high energy environment. TerraSond recommends a cable easement evaluation and planning strategy which will inform the YRITWC about options for submerged power transmission cable routing, protective shielding strategies, and anchoring methodologies. Terrasond believes that his effort will not require additional data acquisition, but will require professional software and personnel with expertise in cable route planning. The YRITWC project considered surface turbine infrastructure, however, a thorough resource assessment may consider the generation of the electric power under variations in the technology and the seasonal scenarios. TerraSond recommends extending the same moored ADCP measurement of the Yukon River resource through a winter season. Information has been acquired, but not evaluated for submerged turbine power production for this project site. Nor does the current YRITWC project include subsurface technology deployment methodologies in its proof-of-concept project. In conjunction with the work mentioned above, TerraSond believes that an evaluation of this site for extended season and winter power conversion could be accomplished through the modeling efforts described above. TerraSond is not recommending this site for winter power production, not enough information exists to support or discourage this concept. TerraSond does believe that a measurement of the river current velocities through a winter season would inform and quantify the power production potential for the site and appropriately complete the evaluation. Alaska academic researchers are currently leading efforts in the Instream Hydrokinetic Industry in pursuit of processing methodologies and quantify turbulent current indicators and variables from ADCP information. TerraSond does believe that the Yukon River at Ruby would provide a unique and non-similar environment (to other turbulence research sites) for the efforts pursued by this Alaska Research Group. If desired, TerraSond would acquire information with the ADCP instrumentation listed above under the direction, standards, and criteria of the turbulence research. This accomplishment would have benefit for the State of Alaska as it would continue and diversify the body of knowledge for turbulent behavior in the power generating river systems of Alaska. This information will be used to increase the meaningfulness of river models projecting the life expectancy and survivability, and ultimately, contribute to the evaluations of overall cost benefit of Hydrokinetic Projects in Alaskan Riverine systems. In conclusion, if each of the recommendations listed above were funded and supported, TerraSond believes that the Yukon River Inter-Tribal Watershed Council In-river Power Conversion Proof-of-Concept Project at Ruby would be able to be evaluated in quantifiable PROJECT NO 2009-021 5-39 MAY 2010 terms as a comparison of natural resource per the power generation cost benefit over variations in season length, extreme river conditions, and for turbine technologies. This recommended effort would primarily be a processing and modeling effort with several long term data acquisition programs with minimal infield man power expectations. The foundation for the products has already been accomplished through the 2009 survey, however, additional resource assessment measurements will be required in order to accomplish and deepen the understanding of the resource and identify its relationship with power generation. For long term or permanent and persistent hydrokinetic power conversion site, TerraSond recommends a reconnaissance of the vicinity of Ruby for sites that present with additional natural power, quality substrate for anchoring, and areas that are conducive for bottom lay cables. TerraSond has not accomplished this investigation, however, our supplemental information does indicate that sites with this description may exist in the immediate vicinity of Ruby. The Proof of concept site may not be the most ideal for low infrastructure deployment areas or as a site for peak performance. PROJECT NO 2009-021 5-40 MAY 2010 This page intentionally left blank. APPENDIX A GEODETIC INFORMATION The NGS Data Sheet See file dsdata.txt for more information about the datasheet. DATABASE = ,PROGRAM = datasheet, VERSION = 7.85 1 National Geodetic Survey, Retrieval Date = MAY 8, 2010 DH9335 *********************************************************************** DH9335 PACS - This is a Primary Airport Control Station. DH9335 DESIGNATION - RBY A DH9335 PID - DH9335 DH9335 STATE/COUNTY- AK/YUKON-KOYUKUK CENSUS DH9335 USGS QUAD - RUBY C-5 DH9335 DH9335 *CURRENT SURVEY CONTROL DH9335 ___________________________________________________________________ DH9335* NAD 83(1992)- 64 43 48.85106(N) 155 27 47.12009(W) ADJUSTED DH9335* NAVD 88 - 198.57 (meters) 651.5 (feet) GPS OBS DH9335 ___________________________________________________________________ DH9335 X - -2,483,714.764 (meters) COMP DH9335 Y - -1,133,826.966 (meters) COMP DH9335 Z - 5,745,121.826 (meters) COMP DH9335 LAPLACE CORR- 1.18 (seconds) DEFLEC09 DH9335 ELLIP HEIGHT- 206.583 (meters) (05/04/06) ADJUSTED DH9335 GEOID HEIGHT- 8.14 (meters) GEOID09 DH9335 HORZ ORDER - B DH9335 ELLP ORDER - THIRD CLASS I DH9335 DH9335.This mark is at Ruby Airport (RBY) DH9335 DH9335.The horizontal coordinates were established by GPS observations DH9335.and adjusted by the R + M CONSULTANTS INCORPORATED in May 2006. DH9335 DH9335.The orthometric height was determined by GPS observations and a DH9335.high-resolution geoid model. DH9335 DH9335.GPS derived orthometric heights for airport stations designated as DH9335.PACS or SACS are published to 2 decimal places. This maintains DH9335.centimeter relative accuracy between the PACS and SACS. It does DH9335.not indicate centimeter accuracy relative to other marks which are DH9335.part of the NAVD 88 network. DH9335 DH9335.The X, Y, and Z were computed from the position and the ellipsoidal ht. DH9335 DH9335.The Laplace correction was computed from DEFLEC09 derived deflections. DH9335 DH9335.The ellipsoidal height was determined by GPS observations DH9335.and is referenced to NAD 83. DH9335 DH9335.The geoid height was determined by GEOID09. DH9335 DH9335; North East Units Scale Factor Converg. DH9335;SPC AK 5 - 1,196,032.341 430,294.498 MT 0.99995947 -1 19 23.3 DH9335;UTM 05 - 7,180,670.994 382,701.871 MT 0.99976846 -2 13 39.5 DH9335 DH9335! - Elev Factor x Scale Factor = Combined Factor DH9335!SPC AK 5 - 0.99996768 x 0.99995947 = 0.99992715 DH9335!UTM 05 - 0.99996768 x 0.99976846 = 0.99973615 DH9335 DH9335|---------------------------------------------------------------------| DATASHEETS http://www.ngs.noaa.gov/cgi-bin/ds_radius.prl 1 of 2 5/8/2010 2:56 PM DH9335| PID Reference Object Distance Geod. Az | DH9335| dddmmss.s | DH9335| DH9337 RBY C 105.143 METERS 16054 | DH9335|---------------------------------------------------------------------| DH9335 DH9335 SUPERSEDED SURVEY CONTROL DH9335 DH9335.No superseded survey control is available for this station. DH9335 DH9335_U.S. NATIONAL GRID SPATIAL ADDRESS: 5WLM8270180670(NAD 83) DH9335_MARKER: DD = SURVEY DISK DH9335_SETTING: 17 = SET INTO TOP OF METAL PIPE DRIVEN INTO GROUND DH9335_STAMPING: RBY A-2005 DH9335_MARK LOGO: NGS DH9335_PROJECTION: RECESSED 6 CENTIMETERS DH9335_MAGNETIC: B = BAR MAGNET IMBEDDED IN MONUMENT DH9335_STABILITY: C = MAY HOLD, BUT OF TYPE COMMONLY SUBJECT TO DH9335+STABILITY: SURFACE MOTION DH9335_SATELLITE: THE SITE LOCATION WAS REPORTED AS SUITABLE FOR DH9335+SATELLITE: SATELLITE OBSERVATIONS - March 12, 2005 DH9335_ROD/PIPE-DEPTH: 0.8 meters DH9335 DH9335 HISTORY - Date Condition Report By DH9335 HISTORY - 20050312 MONUMENTED R+MCON DH9335 DH9335 STATION DESCRIPTION DH9335 DH9335'DESCRIBED BY R + M CONSULTANTS INCORPORATED 2005 (DCH) DH9335'THE STATION IS LOCATED ALONG THE NORTH SIDE OF THE RUNWAY AT THE RUBY DH9335'AIRPORT IN RUBY, ALASKA. OWNERSHIP -- STATE OF ALASKA, C/O BILL DH9335'O'HALLORAN AIRPORT MANAGER, 2301 PEGER ROAD, FAIRBANKS AK 99709, DH9335'PHONE NUMBER 907-451-5250, FAX NUMBER 907-451-2220. THE AIRPORT IS DH9335'UNRESTRICTED. THE VILLAGE HAS TRANSPORTATION AND LODGING LOCALLY. DH9335' DH9335'TO REACH THE STATION FROM THE MERRELINE A. KANGAS ELEMENTARY AND DH9335'SECONDARY SCHOOL IN RUBY, ALASKA, FOLLOW THE AIRPORT ROAD SOUTHERLY DH9335'FOR 0.6 MILES TO THE EDGE OF THE AIRPORT APRON, PROCEED SOUTHWESTERLY DH9335'ALONG THE TAXIWAY TO THE RUNWAY, AND FOLLOW A DIRT ROAD THAT DH9335'PARALLELS THE RUNWAY ON THE NORTH SIDE, WESTERLY FOR 0.05 MILES TO THE DH9335'STATION WHICH LAY APPOXIMATELY 200' NORTH OF THE NORTH EDGE OF THE DH9335'RUNWAY. DH9335' DH9335'THE STATION IS A NONSTANDARD NGS 0.083 M (0.271 FT) DIAMETER BY 0.914 DH9335'M (3.0 FT) LONG STAINLESS STEEL PIPE FLARED AT THE BASE. THE STATION DH9335'IS LOCATED 39.2 M (128.5 FT) 206 DEGREES MAGNETIC AZIMUTH FROM A WIND DH9335'SOCK, 63.1 M (207.0 FT) 166 DEGREES MAGNETIC AZIMUTH FROM THE AWAS DH9335'STRUCTURE, AND 45.4 M (149.0 FT) 271 DEGREES MAGNETIC AZIMUTH FROM DH9335'THE SECOND RUNWAY LIGHT SOUTHWEST OF THE TAXIWAY ON THE NORTH SIDE OF DH9335'THE RUNWAY. THIS STATION IS DESIGNATED AS THE PRIMARY AIRPORT CONTROL DH9335'STATION. *** retrieval complete. Elapsed Time = 00:00:01 DATASHEETS http://www.ngs.noaa.gov/cgi-bin/ds_radius.prl 2 of 2 5/8/2010 2:56 PM APPENDIX B CURRENT MAGNITUDE IMAGES   APPENDIX C DVD – PROCESSED DATA APPENDIX D FLEDERMAUS DIGITAL PRESENTATION APPENDIX E 2009 TURBINE PLACEMENT POSTER