HomeMy WebLinkAboutFY20 Power Cost Equalization Statistical Report Community Version 06-30-2020-PCE
POWER COST
EQUALIZATION
PROGRAM
STATISTICAL REPORT
FY2020
Safe,
Reliable, and
Affordable
Energy
Solutions
POWER COST EQUALIZATION PROGRAM
Statistical Data by Community
Reporting Period: 07/01/19..06/30/20
Table of Contents
Program Highlights……………………………………………….…………………………………...……...7
Fiscal Year 2019 vs. 2020………………………………………………….………………………………….8
Historical Trends Fiscal Years 2011 - 2020……………………..…………………………………….9
List of Participating Utilities/Communities………………………………...……………………….10
Map of Participating Utilities/Communities……………………………………………….…………………………………..11
Adak…………………………………………………………………………...…………………………….……………………………………..12
Akhiok…………………………………………………………………………...…………………………….……………………………………..13
Akiachak…………………………………………………………………………...…………………………….……………………………………..14
Akiak…………………………………………………………………………...…………………………….……………………………………..15
Akutan…………………………………………………………………………...…………………………….……………………………………..16
Alakanuk…………………………………………………………………………...…………………………….……………………………………..17
Allakaket; Alatna…………………………………………………………………………...…………………………….……………………………………..18
Ambler…………………………………………………………………………...…………………………….……………………………………..19
Anaktuvuk Pass…………………………………………………………………………...…………………………….……………………………………..20
Angoon…………………………………………………………………………...…………………………….……………………………………..21
Aniak…………………………………………………………………………...…………………………….……………………………………..22
Anvik…………………………………………………………………………...…………………………….……………………………………..23
Arctic Village…………………………………………………………………………...…………………………….……………………………………..24
Atka…………………………………………………………………………...…………………………….……………………………………..25
Atmautluak…………………………………………………………………………...…………………………….……………………………………..26
Atqasuk…………………………………………………………………………...…………………………….……………………………………..27
Beaver…………………………………………………………………………...…………………………….……………………………………..28
Bethel; Oscarville…………………………………………………………………………...…………………………….……………………………………..29
Bettles; Evansville…………………………………………………………………………...…………………………….……………………………………..30
Birch Creek…………………………………………………………………………...…………………………….……………………………………..31
Brevig Mission…………………………………………………………………………...…………………………….……………………………………..32
Buckland…………………………………………………………………………...…………………………….……………………………………..33
Central…………………………………………………………………………...…………………………….……………………………………..34
Chalkyitsik…………………………………………………………………………...…………………………….……………………………………..35
Chefornak…………………………………………………………………………...…………………………….……………………………………..36
Chenega Bay…………………………………………………………………………...…………………………….……………………………………..37
Chevak…………………………………………………………………………...…………………………….……………………………………..38
Chignik Lagoon…………………………………………………………………………...…………………………….……………………………………..39
Chignik Lake…………………………………………………………………………...…………………………….……………………………………..40
Chignik…………………………………………………………………………...…………………………….……………………………………..41
Chilkat Valley…………………………………………………………………………...…………………………….……………………………………..42
Chistochina…………………………………………………………………………...…………………………….……………………………………..43
Chitina…………………………………………………………………………...…………………………….……………………………………..44
Chuathbaluk…………………………………………………………………………...…………………………….……………………………………..45
Page 2 of 187
POWER COST EQUALIZATION PROGRAM
Statistical Data by Community
Reporting Period: 07/01/19..06/30/20
Table of Contents
Circle…………………………………………………………………………...…………………………….……………………………………..46
Clark's Point…………………………………………………………………………...…………………………….……………………………………..47
Coffman Cove…………………………………………………………………………...…………………………….……………………………………..48
Cold Bay…………………………………………………………………………...…………………………….……………………………………..49
Cordova…………………………………………………………………………...…………………………….……………………………………..50
Craig…………………………………………………………………………...…………………………….……………………………………..51
Crooked Creek…………………………………………………………………………...…………………………….……………………………………..52
Deering…………………………………………………………………………...…………………………….……………………………………..53
Dillingham; Aleknagik…………………………………………………………………………...…………………………….……………………………………..54
Diomede…………………………………………………………………………...…………………………….……………………………………..55
Dot Lake; Dot Lake Village…………………………………………………………………………...…………………………….……………………………………..56
Eagle; Eagle Village…………………………………………………………………………...…………………………….……………………………………..57
Eek…………………………………………………………………………...…………………………….……………………………………..58
Egegik…………………………………………………………………………...…………………………….……………………………………..59
Ekwok…………………………………………………………………………...…………………………….……………………………………..60
Elfin Cove…………………………………………………………………………...…………………………….……………………………………..61
Elim…………………………………………………………………………...…………………………….……………………………………..62
Emmonak…………………………………………………………………………...…………………………….……………………………………..63
False Pass…………………………………………………………………………...…………………………….……………………………………..64
Fort Yukon…………………………………………………………………………...…………………………….……………………………………..65
Galena…………………………………………………………………………...…………………………….……………………………………..66
Gambell…………………………………………………………………………...…………………………….……………………………………..67
Golovin…………………………………………………………………………...…………………………….……………………………………..68
Goodnews Bay…………………………………………………………………………...…………………………….……………………………………..69
Grayling…………………………………………………………………………...…………………………….……………………………………..70
Gustavus…………………………………………………………………………...…………………………….……………………………………..71
Haines; Covenant Life…………………………………………………………………………...…………………………….……………………………………..72
Healy Lake…………………………………………………………………………...…………………………….……………………………………..73
Hollis…………………………………………………………………………...…………………………….……………………………………..74
Holy Cross…………………………………………………………………………...…………………………….……………………………………..75
Hoonah…………………………………………………………………………...…………………………….……………………………………..76
Hooper Bay…………………………………………………………………………...…………………………….……………………………………..77
Hughes…………………………………………………………………………...…………………………….……………………………………..78
Huslia…………………………………………………………………………...…………………………….……………………………………..79
Hydaburg…………………………………………………………………………...…………………………….……………………………………..80
Igiugig…………………………………………………………………………...…………………………….……………………………………..81
Iliamna Newhalen Nondalton…………………………………………………………………………...…………………………….……………………………………..82
Kake…………………………………………………………………………...…………………………….……………………………………..83
Kaktovik…………………………………………………………………………...…………………………….……………………………………..84
Kaltag…………………………………………………………………………...…………………………….……………………………………..85
Karluk…………………………………………………………………………...…………………………….……………………………………..86
Page 3 of 187
POWER COST EQUALIZATION PROGRAM
Statistical Data by Community
Reporting Period: 07/01/19..06/30/20
Table of Contents
Kasigluk…………………………………………………………………………...…………………………….……………………………………..87
Kiana…………………………………………………………………………...…………………………….……………………………………..88
Kipnuk…………………………………………………………………………...…………………………….……………………………………..89
Kivalina…………………………………………………………………………...…………………………….……………………………………..90
Klawock…………………………………………………………………………...…………………………….……………………………………..91
Klukwan…………………………………………………………………………...…………………………….……………………………………..92
Kobuk…………………………………………………………………………...…………………………….……………………………………..93
Kokhanok…………………………………………………………………………...…………………………….……………………………………..94
Koliganek…………………………………………………………………………...…………………………….……………………………………..95
Kongiganak…………………………………………………………………………...…………………………….……………………………………..96
Kotlik…………………………………………………………………………...…………………………….……………………………………..97
Kotzebue…………………………………………………………………………...…………………………….……………………………………..98
Koyuk…………………………………………………………………………...…………………………….……………………………………..99
Koyukuk…………………………………………………………………………...…………………………….……………………………………..100
Kwethluk…………………………………………………………………………...…………………………….……………………………………..101
Kwigillingok…………………………………………………………………………...…………………………….……………………………………..102
Larsen Bay…………………………………………………………………………...…………………………….……………………………………..103
Levelock…………………………………………………………………………...…………………………….……………………………………..104
Lime Village…………………………………………………………………………...…………………………….……………………………………..105
Lower Kalskag…………………………………………………………………………...…………………………….……………………………………..106
Manley Hot Springs…………………………………………………………………………...…………………………….……………………………………..107
Manokotak…………………………………………………………………………...…………………………….……………………………………..108
Marshall…………………………………………………………………………...…………………………….……………………………………..109
McGrath…………………………………………………………………………...…………………………….……………………………………..110
Mekoryuk…………………………………………………………………………...…………………………….……………………………………..111
Mentasta…………………………………………………………………………...…………………………….……………………………………..112
Minto…………………………………………………………………………...…………………………….……………………………………..113
Mt. Village…………………………………………………………………………...…………………………….……………………………………..114
Naknek;S.Naknek;Kng Slmn…………………………………………………………………………...…………………………….……………………………………..115
Napakiak…………………………………………………………………………...…………………………….……………………………………..116
Napaskiak…………………………………………………………………………...…………………………….……………………………………..117
Naukati…………………………………………………………………………...…………………………….……………………………………..118
Nelson Lagoon…………………………………………………………………………...…………………………….……………………………………..119
New Stuyahok…………………………………………………………………………...…………………………….……………………………………..120
Newtok…………………………………………………………………………...…………………………….……………………………………..121
Nightmute…………………………………………………………………………...…………………………….……………………………………..122
Nikolai…………………………………………………………………………...…………………………….……………………………………..123
Nikolski…………………………………………………………………………...…………………………….……………………………………..124
Noatak…………………………………………………………………………...…………………………….……………………………………..125
Nome…………………………………………………………………………...…………………………….……………………………………..126
Noorvik…………………………………………………………………………...…………………………….……………………………………..127
Page 4 of 187
POWER COST EQUALIZATION PROGRAM
Statistical Data by Community
Reporting Period: 07/01/19..06/30/20
Table of Contents
Northway; Northway Village…………………………………………………………………………...…………………………….……………………………………..128
Nuiqsut…………………………………………………………………………...…………………………….……………………………………..129
Nulato…………………………………………………………………………...…………………………….……………………………………..130
Nunam Iqua…………………………………………………………………………...…………………………….……………………………………..131
Nunapitchuk…………………………………………………………………………...…………………………….……………………………………..132
Old Harbor…………………………………………………………………………...…………………………….……………………………………..133
Ouzinkie…………………………………………………………………………...…………………………….……………………………………..134
Pedro Bay…………………………………………………………………………...…………………………….……………………………………..135
Perryville…………………………………………………………………………...…………………………….……………………………………..136
Pilot Point…………………………………………………………………………...…………………………….……………………………………..137
Pilot Station…………………………………………………………………………...…………………………….……………………………………..138
Pitkas Point…………………………………………………………………………...…………………………….……………………………………..139
Point Hope…………………………………………………………………………...…………………………….……………………………………..140
Point Lay…………………………………………………………………………...…………………………….……………………………………..141
Port Alsworth…………………………………………………………………………...…………………………….……………………………………..142
Port Heiden…………………………………………………………………………...…………………………….……………………………………..143
Quinhagak…………………………………………………………………………...…………………………….……………………………………..144
Rampart…………………………………………………………………………...…………………………….……………………………………..145
Red Devil…………………………………………………………………………...…………………………….……………………………………..146
Ruby…………………………………………………………………………...…………………………….……………………………………..147
Russian Mission…………………………………………………………………………...…………………………….……………………………………..148
Sand Point…………………………………………………………………………...…………………………….……………………………………..149
Savoonga…………………………………………………………………………...…………………………….……………………………………..150
Scammon Bay…………………………………………………………………………...…………………………….……………………………………..151
Selawik…………………………………………………………………………...…………………………….……………………………………..152
Shageluk…………………………………………………………………………...…………………………….……………………………………..153
Shaktoolik…………………………………………………………………………...…………………………….……………………………………..154
Shishmaref…………………………………………………………………………...…………………………….……………………………………..155
Shungnak…………………………………………………………………………...…………………………….……………………………………..156
Skagway…………………………………………………………………………...…………………………….……………………………………..157
Slana…………………………………………………………………………...…………………………….……………………………………..158
Sleetmute…………………………………………………………………………...…………………………….……………………………………..159
St. George…………………………………………………………………………...…………………………….……………………………………..160
St. Mary's; Andreafsky…………………………………………………………………………...…………………………….……………………………………..161
St. Michael…………………………………………………………………………...…………………………….……………………………………..162
St. Paul…………………………………………………………………………...…………………………….……………………………………..163
Stebbins…………………………………………………………………………...…………………………….……………………………………..164
Stony River…………………………………………………………………………...…………………………….……………………………………..165
Takotna…………………………………………………………………………...…………………………….……………………………………..166
Tanana…………………………………………………………………………...…………………………….……………………………………..167
Tatitlek…………………………………………………………………………...…………………………….……………………………………..168
Page 5 of 187
POWER COST EQUALIZATION PROGRAM
Statistical Data by Community
Reporting Period: 07/01/19..06/30/20
Table of Contents
Teller…………………………………………………………………………...…………………………….……………………………………..169
Tenakee Springs…………………………………………………………………………...…………………………….……………………………………..170
Tetlin…………………………………………………………………………...…………………………….……………………………………..171
Thorne Bay; Kasaan…………………………………………………………………………...…………………………….……………………………………..172
Togiak…………………………………………………………………………...…………………………….……………………………………..173
Tok; Tanacross…………………………………………………………………………...…………………………….……………………………………..174
Toksook Bay…………………………………………………………………………...…………………………….……………………………………..175
Tuntutuliak…………………………………………………………………………...…………………………….……………………………………..176
Tununak…………………………………………………………………………...…………………………….……………………………………..177
Twin Hills…………………………………………………………………………...…………………………….……………………………………..178
Unalakleet…………………………………………………………………………...…………………………….……………………………………..179
Unalaska…………………………………………………………………………...…………………………….……………………………………..180
Upper Kalskag…………………………………………………………………………...…………………………….……………………………………..181
Venetie…………………………………………………………………………...…………………………….……………………………………..182
Wainwright…………………………………………………………………………...…………………………….……………………………………..183
Wales…………………………………………………………………………...…………………………….……………………………………..184
Whale Pass…………………………………………………………………………...…………………………….……………………………………..185
White Mountain…………………………………………………………………………...…………………………….……………………………………..186
Yakutat…………………………………………………………………………...…………………………….……………………………………..187
Page 6 of 187
Page 7 of 187
HIGHLIGHTS OF THE POWER COST EQUALIZATION PROGRAM
Eligibility
Utility
An electric utility participating in the Power Cost Equalization Program (PCE) must:
a) provide electric service to the public for compensation; b) during calendar year 1983, had
less than 7,500 megawatt hours of residential consumption or less than 15,000 megawatt
hours if two or more communities were served; and c) during calendar year 1984, the utility
has used diesel-fired generators to produce more than 75% of its electrical consumption.
Customers
Customer eligibility is based on actual power purchased. State and federal offices/facilities,
commercial customers and public schools are excluded from PCE. Residential customers
are eligible for PCE credit up to 500 kilowatt-hours (kWh/s) per month. Community
facilities, as a group, can receive PCE credit for up to 70 kilowatt-hours per month multiplied
by the number of residents in a community.
Formula Used to determine PCE level/kWh for a utility:
Formula: 95% of the eligible costs per kWh between
19.10 cents/kWh, “the floor”
and $1.00/kWh, “the ceiling”.
Costs below 19.10 cents/kWh and above $1.00/kWh are not eligible for PCE.
If the eligible costs are $1.00/kWh or more, the maximum PCE level is 76.86 cents/kWh.
($1.00 – 19.10 cents = 80.90 cents x 95% = 76.86 cents).
A participating utility must meet generation efficiency and line loss standards; otherwise the
PCE level is reduced to reflect those standards.
Process
The Regulatory Commission of Alaska (RCA)
RCA determines the PCE level per kWh for each utility. Two categories of costs are used
in determining the PCE level: a) fuel expenses: the cost of fuel, including transportation of
fuel; and b) non-fuel expenses: salaries, insurance, taxes, power plant parts and supplies,
interest and other reasonable costs.
The Alaska Energy Authority (AEA)
Eligible utilities submit monthly reports to AEA that document the eligible power sold and
PCE credits applied to eligible customers’ bills. AEA calculates the amount of PCE on a
monthly basis and issues payment to the utility. AEA verifies the eligibility of customers and
of community facilities. In addition, AEA calculates the required pro-rated PCE levels based
on available funds.
Authority
PCE is governed by Alaska Statutes 42.45.110-170, and by the Alaska Administrative Code
3 AAC 107.200-270 and 3 AAC 52.600-690.
POWER COST EQUALIZATION PROGRAM STATISTICS
FISCAL YR FISCAL YR % CHANGE
See (6)
2019 2020 2019-2020%
Participation Statistics
Population Served 81,997 81,694 -0.4%
Communities Served 193 191 -1.0%
Participating Utilities 88 86 -2.3%
Total Residential Customers (7)28,338 28,158 -0.6%
Total Community Facilities Customers (7)2,069 1,984 -4.1%
Total Customers (Residential & Community Facilities) (1) (7)30,407 30,142 -0.9%
Production Statistics
Total Diesel Generation (kWh)388,091,981 388,166,214 0.0%
Total "Other" (Hydro/Wind/Solar/Natural Gas) Generation (kWh)44,822,777 48,425,017 8.0%
Total Purchased Power (kWh)52,407,617 53,136,733 1.4%
Total kWh Sold (All Customers) (2) (3)453,598,343 455,730,358 0.5%
PCE Eligible Residential kWh 95,605,829 96,544,210 1.0%
PCE Eligible Community kWh 34,190,968 34,946,022 2.2%
Total PCE Eligible - Community Facilities & Residential 129,796,797 131,490,232 1.3%
Total PCE Eligible kWh Shown as Percent of Total kWh Sold 29%29%0.8%
Average Monthly PCE Eligible kWh - Residential Customers (3)281 286 1.6%
Average Monthly PCE Eligible kWh - Community Facilities (3)1,377 1,468 6.6%
Average Monthly PCE Eligible kWh - Community Facilities / Per Resident (3)35 36 2.6%
Financial Statistics
Average Price of Fuel Oil ($/gallon)3.0603 3.0700 0.3%
Total Fuel Oil Consumed (gallons)28,425,146 28,199,707 -0.8%
Total Cost of Fuel Oil Purchased by the Utilities ($)86,989,310 86,638,172 -0.4%
Total Non-Fuel Expenses ($) (6)85,813,619 87,853,342 2.4%
Non-Fuel Expenses per Total kWh Sold ($) (6)0.1892 0.1928 1.9%
Total Operating Costs per kWh ($) Sold (4)0.3810 0.3829 0.5%
PCE Legislative Funding Appropriations for Utility Payments 32,355,000 32,355,000 0.0%
Total Monthly Reports/PCE Reimbursements to Utilities Processed (5)28,357,347 29,006,012 2.3%
(1) Assumes all customers were eligible to receive PCE credit.
(2) Value reduced by 1,442,713 in FY19 and 1,838,561 in FY20 to eliminate double counting of kWh's
where power is sold/purchased between utilities participating in the PCE Program.
(3) Calculation assumes all residential and community facility customers
were eligible to receive twelve (12) months of PCE credit.
(4) "Operating" costs include both fuel and non-fuel expenses.
(5) During FY19 and FY20 PCE payments were made at a 100% level for all 12 months.
(6) Net change between years is partially attributable to incomplete reporting by utilties
(7) Total Customers represents the number of customers reported by the utility for the last reported month.
Page 8 of 187
POWER COST EQUALIZATION PROGRAM
HISTORICAL TRENDS
Fiscal Year 2011 - 2020
2011 2012 2013 2014 2015 2016 2017 2018 2019 2020
PARTICIPATION
Participating Utilities 83 87 88 87 86 88 89 89 88 86
Communities Served 183 188 190 190 190 191 194 194 193 191
Population Served 77,341 79,644 81,693 82,427 81,969 82,986 83,850 83,400 81,997 81,694
PCE ELIGIBLE CUSTOMERS
Residential 26,753 27,402 27,795 27,716 27,893 28,035 27,857 28,365 28,338 28,158
Community Facilities 1,888 1,919 1,900 1,889 1,850 2,056 2,067 2,090 2,069 1,984
Total Customers 28,641 29,321 29,695 29,605 29,743 30,091 29,924 30,455 30,407 30,142
FUNDING
Appropriations ($)$36,000,000 $39,150,000 $40,100,000 $41,006,000 $41,000,000 $41,000,000 $40,000,000 $32,355,000 $32,355,000 $32,355
Disbursements ($)$31,810,803 $39,059,864 $39,715,618 $39,571,659 $37,379,742 $31,042,569 $26,099,807 $26,182,235 $28,357,347 $29,006,012
Disbursements/Customer ($)$1,111 $1,332 $1,337 $1,337 $1,257 $1,032 $872 $860 $933 $962
Funding Level 100%100%100%100%100%100%100%100%100%100%
CONSUMPTION
Total MWh Sold (MWH)437,266 459,056 463,573 452,751 450,852 447,333 462,998 458,734 453,598 455,730
PCE Eligible MWh Residential 93,175 96,666 97,102 95,990 96,453 94,816 97,751 96,597 95,606 96,544
Avg. PCE Eligible kWh/Month/Residential Cust 290 294 291 289 288 282 292 284 281 285
PCE Eligible MWh Community Facilities 33,116 34,750 34,743 33,409 32,795 34,357 35,747 34,929 34,191 34,946
Elig. kWh/Month/Capita, Community Facilities 36.0 36.0 35.0 34.0 33.3 35.0 36.0 35.0 34.7 35.6
Total PCE Eligible MWh 126,291 131,417 131,845 129,414 129,248 129,173 133,498 131,526 129,797 131,490
Eligible kWh/Month/Cust, Total Customers 367 374 370 364 362 358 372 360 356 364
COSTS
Average Price of Fuel Oil ($/gallon)$3.45 $4.02 $4.21 $4.21 $3.97 $3.24 $2.66 $2.86 $3.06 $3.07
Total Gallons of Fuel Oil Consumed 28,159,847 29,204,577 28,957,490 27,919,599 27,191,149 26,865,206 28,838,704 28,638,535 28,425,146 28,199,707
Total Cost of Fuel Oil ($)$97,042,004 $117,313,926 $121,707,897 $117,483,188 $107,842,372 $87,102,302 $76,759,457 $76,137,419 $86,989,310 $86,638,172
Total Non-Fuel Costs ($)$60,012,748 $69,554,141 $79,772,882 $73,336,386 $76,036,533 $82,964,017 $85,141,895 $89,505,362 $85,813,619 $82,740,877
FINANCIAL RATIOS
Non-Fuel Costs Per Total kWh Sold 0.1372$ 0.1515$ 0.1721$ 0.1620$ 0.1687$ 0.1855$ 0.1839$ 0.1770$ 0.1892$ 0.1816$
Total Operating Costs Per Total kWh Sold 0.3592$ 0.4071$ 0.4346$ 0.4215$ 0.4078$ 0.3802$ 0.3497$ 0.3276$ 0.3810$ 0.3717$
RATES
Avg. PCE per Eligible kWh Res. & Comm Facility ($/kWh) 0.2519$ 0.2972$ 0.3012$ 0.3058$ 0.2892$ 0.2403$ 0.1955$ 0.3021$ 0.2185$ 0.2206$
Weighted Avg. Residential Rate (Before PCE Paid)0.4756$ 0.5131$ 0.4973$ 0.5005$ 0.4915$ 0.4541$ 0.4270$ 0.4226$ 0.4618$ 0.4630$
Weighted Avg. Residential PCE Rate (Amount PCE pays)0.2592$ 0.3044$ 0.3064$ 0.3108$ 0.2919$ 0.2432$ 0.1983$ 0.1987$ 0.2191$ 0.2226$
Weighted Avg. Residential Effective Rate (1)0.2164$ 0.2087$ 0.1909$ 0.1897$ 0.1996$ 0.2109$ 0.2287$ 0.2239$ 0.2427$ 0.2404$
(1) Amount customers pay for first 500 kWh/month.
Page 9 of 187
Birch Creek Electric Napaskiak Electric Utility
Buckland, City of Naterkaq Light Plant
Chalkyitsik Village Council Chefornak
Chenega IRA Village Council Nelson Lagoon Electrical Cooperative
Chignik, City of New Koliganek Village Council
Allakaket / Alatna Hydaburg Chignik Lagoon Power Utility Koliganek
Bettles / Evansville Klawock Chignik Lake Electric Nikolai, City of
Chistochina Mentasta Chitina Electric Inc.Nome Joint Utility System
Coffman Cove Naukati Circle Electric Utility North Slope Borough
Craig Northway / Northway Village Clarks Point Village Council Anaktuvuk Pass Point Hope
Dot Lake / Dot Lake Village Skagway Cordova Electric Co-op Atqasuk Point Lay
Eagle / Eagle Village Slana Cordova Eyak Kaktovik Wainwright
Gustavus Tetlin Diomede Joint Utilities Nuiqsut
Haines / Covenant Life Thorne Bay / Kassan Egegik Light and Power Nunam Iqua Electric Company
Healy Tok / Tanacross Elfin Cove Utility Commission Nushagak Electric Cooperative
Hollis Whale Pass False Pass, City of Aleknagik / Dillingham
Alaska Village Electric Cooperative Galena, City of Ouzinkie, City of
Alakanuk Nightmute G & K Inc.Pedro Bay Village Council
Ambler Noatak Cold Bay Perryville, Native Village Of
Anvik Noorvik Gold Country Energy Pilot Point Electrical
Bethel / Oscarville Nulato Central Port Heiden Utilities
Brevig Mission Nunapitchuk Golovin Power Utilities Puvurnaq Power Company
Chevak Old Harbor Gwitchyaa Zhee Utilities Kongiganak
Eek Pilot Station Fort Yukon Rampart Village Council Electric
Ekwok Pitka's Point Hughes Power & Light Ruby, City of
Elim Quinhagak Igiugig Electric Company St. George, City of
Emmonak Russian Mission I-N-N Electric Cooperative St. Paul Municipal Electric
Gambell Savoonga Iliamna / Newhalen / Nondalton Takotna Community Assoc. Inc.
Goodnews Bay Scammon Bay Inside Passage Electric Cooperative Tanalian Electric Cooperative
Grayling Selawik Angoon Kake Port Alsworth
Holy Cross Shageluk Chilkat Valley Klukwan Tanana Power Company Inc.
Hooper Bay Shaktoolik Hoonah Tatitlek Village IRA Council
Huslia Shishmaref Ipnatchiaq Electric Company TDX Adak Generating LLC
Kaltag Shungnak Deering Adak
Kasigluk St. Mary's / Andreafsky Kipnuk Light Plant TDX Corporation
Kiana St. Michael Kokhanok Village Council Sand Point
Kivalina Stebbins Kotzebue Electric Association TDX Manley Generating LLC
Kobuk Teller Koyukuk, City of Manley Hot Springs
Kotlik Togiak Kwethluk Incorporated Tenakee Springs, City of
Koyuk Toksook Bay Kwigillingok IRA Council Tuntutuliak Community Service Assoc.
Lower Kalskag Tununak Larsen Bay Utility Company Twin Hills Village Council
Marshall Upper Kalskag Levelock Electrical Coop Umnak Power Company
Mekoryuk Wales Lime Village Electric Utility Nikolski
Minto Yakutat Manokotak Power Company Unalakleet Valley Electrical Cooperative
Mt. Village McGrath Light & Power Unalaska, City of
New Stuyahok Middle Kuskokwim Electric Ungusrag Power Company
Alutiiq Power Company Chuathbaluk Sleetmute Newtok
Karluk Crooked Creek Stony River Venetie Village Electric
Aniak Light & Power Company Red Devil White Mountain, City of
Arctic Village Council Naknek Electric
Atka, City of King Salmon
Atmautluak Joint Utilities Naknek / South Naknek
Beaver Joint Utilities Napakiak Ircinraq
FY20 PCE Program Participating Utilities
Akiachak Native Community
Akiak City Council
Alaska Power Company
Akhiok / Kaguyak Electric
Akutan Electric Utility
Page 10 of 187
Adak PCE
Utility: TDX ADAK GENERATING LLC
Reporting Period: 07/01/19..06/30/20
Community Population 296
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 78
Community Facility Customers 7
Other Customers (Non-PCE)116
Fiscal Year PCE Payments $239,685
PCE Statistical Data
PCE Eligible kWh - Residential Customers 179,188 Average Annual PCE Payment per Eligible
Customer
$2,820
PCE Eligible kWh - Community Facility
Customers
134,997 Average PCE Payment per Eligible kWh $0.76
Total PCE Eligible kWh 314,185 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.40
Average Monthly PCE Eligible kWh per
Residential Customer
191 Last Reported PCE Level (per kWh)$0.77
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,607 Effective Residential Rate (per kWh)$0.63
Average Monthly PCE Eligible Community
Facility kWh per Person
38 PCE Eligible kWh vs Total kWh Sold 26.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,072,822 Fuel Used (Gallons)183,988
Non-Diesel kWh Generated 0 Fuel Cost $815,346
Purchased kWh 0 Average Price of Fuel $4.43
Total Purchased & Generated 2,072,822 Fuel Cost per kWh sold $0.68
Annual Non-Fuel Expenses $0
Non-Fuel Expense per kWh Sold See Comments
Total Expense per kWh Sold $0.68
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 220,189 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
57.5%
Community Facility kWh Sold 145,288 Line Loss (%)25.7%
Other kWh Sold (Non-PCE)826,933 Fuel Efficiency (kWh per Gallon of Diesel)11.27
Total kWh Sold 1,192,410 PH Consumption as % of Generation 16.8%
Powerhouse (PH) Consumption kWh 347,781
Total kWh Sold & PH Consumption 1,540,191
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 12 of 187
Akhiok PCE
Utility: AKHIOK/KAGUYAK ELECTRIC
Reporting Period: 07/01/19..06/30/20
Community Population 81
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 27
Community Facility Customers 2
Other Customers (Non-PCE)14
Fiscal Year PCE Payments $34,568
PCE Statistical Data
PCE Eligible kWh - Residential Customers 68,479 Average Annual PCE Payment per Eligible
Customer
$1,192
PCE Eligible kWh - Community Facility
Customers
35,329 Average PCE Payment per Eligible kWh $0.33
Total PCE Eligible kWh 103,808 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.80
Average Monthly PCE Eligible kWh per
Residential Customer
211 Last Reported PCE Level (per kWh)$0.37
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,472 Effective Residential Rate (per kWh)$0.43
Average Monthly PCE Eligible Community
Facility kWh per Person
36 PCE Eligible kWh vs Total kWh Sold 46.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 262,359 Fuel Used (Gallons)25,188
Non-Diesel kWh Generated 0 Fuel Cost $86,863
Purchased kWh 0 Average Price of Fuel $3.45
Total Purchased & Generated 262,359 Fuel Cost per kWh sold $0.39
Annual Non-Fuel Expenses $13,200
Non-Fuel Expense per kWh Sold $0.06
Total Expense per kWh Sold $0.45
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 80,587 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
85.1%
Community Facility kWh Sold 35,329 Line Loss (%)11.3%
Other kWh Sold (Non-PCE)107,463 Fuel Efficiency (kWh per Gallon of Diesel)10.42
Total kWh Sold 223,379 PH Consumption as % of Generation 3.6%
Powerhouse (PH) Consumption kWh 9,322
Total kWh Sold & PH Consumption 232,701
Comments
Non-fuel cost & Powerhouse Consumption = 11 months
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 13 of 187
Akiachak PCE
Utility: AKIACHAK NATIVE COMMUNITY
Reporting Period: 07/01/19..06/30/20
Community Population 713
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 183
Community Facility Customers 10
Other Customers (Non-PCE)51
Fiscal Year PCE Payments $206,533
PCE Statistical Data
PCE Eligible kWh - Residential Customers 604,393 Average Annual PCE Payment per Eligible
Customer
$1,070
PCE Eligible kWh - Community Facility
Customers
172,828 Average PCE Payment per Eligible kWh $0.27
Total PCE Eligible kWh 777,221 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.63
Average Monthly PCE Eligible kWh per
Residential Customer
275 Last Reported PCE Level (per kWh)$0.27
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,440 Effective Residential Rate (per kWh)$0.36
Average Monthly PCE Eligible Community
Facility kWh per Person
20 PCE Eligible kWh vs Total kWh Sold 43.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,772,860 Fuel Used (Gallons)138,125
Non-Diesel kWh Generated 0 Fuel Cost $454,440
Purchased kWh 0 Average Price of Fuel $3.29
Total Purchased & Generated 1,772,860 Fuel Cost per kWh sold $0.26
Annual Non-Fuel Expenses $486,029
Non-Fuel Expense per kWh Sold $0.27
Total Expense per kWh Sold $0.53
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 686,383 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
99.8%
Community Facility kWh Sold 173,155 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)910,168 Fuel Efficiency (kWh per Gallon of Diesel)12.84
Total kWh Sold 1,769,706 PH Consumption as % of Generation 1.9%
Powerhouse (PH) Consumption kWh 33,833
Total kWh Sold & PH Consumption 1,803,539
Comments
kWh's Generated & Powerhouse Consumption = 11 Months
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 14 of 187
Akiak PCE
Utility: AKIAK CITY COUNCIL
Reporting Period: 07/01/19..06/30/20
Community Population 406
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 98
Community Facility Customers 8
Other Customers (Non-PCE)34
Fiscal Year PCE Payments $94,632
PCE Statistical Data
PCE Eligible kWh - Residential Customers 348,288 Average Annual PCE Payment per Eligible
Customer
$893
PCE Eligible kWh - Community Facility
Customers
29,898 Average PCE Payment per Eligible kWh $0.25
Total PCE Eligible kWh 378,186 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.53
Average Monthly PCE Eligible kWh per
Residential Customer
296 Last Reported PCE Level (per kWh)$0.24
Average Monthly PCE Eligible kWh per
Community Facility Customer
311 Effective Residential Rate (per kWh)$0.29
Average Monthly PCE Eligible Community
Facility kWh per Person
6 PCE Eligible kWh vs Total kWh Sold 33.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,228,238 Fuel Used (Gallons)86,855
Non-Diesel kWh Generated 0 Fuel Cost $301,236
Purchased kWh 0 Average Price of Fuel $3.47
Total Purchased & Generated 1,228,238 Fuel Cost per kWh sold $0.27
Annual Non-Fuel Expenses $114,169
Non-Fuel Expense per kWh Sold $0.10
Total Expense per kWh Sold $0.37
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 387,327 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
91.4%
Community Facility kWh Sold 40,156 Line Loss (%)6.0%
Other kWh Sold (Non-PCE)695,499 Fuel Efficiency (kWh per Gallon of Diesel)14.14
Total kWh Sold 1,122,982 PH Consumption as % of Generation 2.5%
Powerhouse (PH) Consumption kWh 31,282
Total kWh Sold & PH Consumption 1,154,264
Comments
kWh's Generated = 9 Months; Fuel Used & Fuel Costs = 11 Months
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 15 of 187
Akutan PCE
Utility: CITY OF AKUTAN
Reporting Period: 07/01/19..06/30/20
Community Population 994
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 44
Community Facility Customers 11
Other Customers (Non-PCE)26
Fiscal Year PCE Payments $223,524
PCE Statistical Data
PCE Eligible kWh - Residential Customers 161,988 Average Annual PCE Payment per Eligible
Customer
$4,064
PCE Eligible kWh - Community Facility
Customers
132,510 Average PCE Payment per Eligible kWh $0.76
Total PCE Eligible kWh 294,498 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.95
Average Monthly PCE Eligible kWh per
Residential Customer
307 Last Reported PCE Level (per kWh)$0.76
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,004 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per Person
11 PCE Eligible kWh vs Total kWh Sold 55.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 447,621 Fuel Used (Gallons)51,918
Non-Diesel kWh Generated 2 Fuel Cost $151,213
Purchased kWh 0 Average Price of Fuel $2.91
Total Purchased & Generated 447,623 Fuel Cost per kWh sold $0.29
Annual Non-Fuel Expenses $183,676
Non-Fuel Expense per kWh Sold $0.35
Total Expense per kWh Sold $0.64
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 184,709 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 132,510 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)209,270 Fuel Efficiency (kWh per Gallon of Diesel)8.62
Total kWh Sold 526,489 PH Consumption as % of Generation 11.8%
Powerhouse (PH) Consumption kWh 53,017
Total kWh Sold & PH Consumption 579,506
Comments
kWh Generated = 8 Months
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 16 of 187
Alakanuk PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 728
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 160
Community Facility Customers 10
Other Customers (Non-PCE)34
Fiscal Year PCE Payments $257,681
PCE Statistical Data
PCE Eligible kWh - Residential Customers 663,043 Average Annual PCE Payment per Eligible
Customer
$1,516
PCE Eligible kWh - Community Facility
Customers
282,720 Average PCE Payment per Eligible kWh $0.27
Total PCE Eligible kWh 945,763 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.54
Average Monthly PCE Eligible kWh per
Residential Customer
345 Last Reported PCE Level (per kWh)$0.27
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,356 Effective Residential Rate (per kWh)$0.27
Average Monthly PCE Eligible Community
Facility kWh per Person
32 PCE Eligible kWh vs Total kWh Sold 49.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $403,047
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.21
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 792,702 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 384,827 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)736,204 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 1,913,733 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 1,913,733
Comments
Receives Power From Emmonak Via Intertie
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 17 of 187
Allakaket; Alatna PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/19..06/30/20
Community Population 189
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 67
Community Facility Customers 16
Other Customers (Non-PCE)18
Fiscal Year PCE Payments $189,387
PCE Statistical Data
PCE Eligible kWh - Residential Customers 195,639 Average Annual PCE Payment per Eligible
Customer
$2,282
PCE Eligible kWh - Community Facility
Customers
128,708 Average PCE Payment per Eligible kWh $0.58
Total PCE Eligible kWh 324,347 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.83
Average Monthly PCE Eligible kWh per
Residential Customer
243 Last Reported PCE Level (per kWh)$0.52
Average Monthly PCE Eligible kWh per
Community Facility Customer
670 Effective Residential Rate (per kWh)$0.31
Average Monthly PCE Eligible Community
Facility kWh per Person
57 PCE Eligible kWh vs Total kWh Sold 58.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 642,169 Fuel Used (Gallons)54,417
Non-Diesel kWh Generated 0 Fuel Cost $265,969
Purchased kWh 0 Average Price of Fuel $4.89
Total Purchased & Generated 642,169 Fuel Cost per kWh sold $0.48
Annual Non-Fuel Expenses $231,455
Non-Fuel Expense per kWh Sold $0.41
Total Expense per kWh Sold $0.89
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 210,317 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
87.0%
Community Facility kWh Sold 142,786 Line Loss (%)9.0%
Other kWh Sold (Non-PCE)205,734 Fuel Efficiency (kWh per Gallon of Diesel)11.80
Total kWh Sold 558,837 PH Consumption as % of Generation 4.0%
Powerhouse (PH) Consumption kWh 25,440
Total kWh Sold & PH Consumption 584,277
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 18 of 187
Ambler PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 287
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 76
Community Facility Customers 15
Other Customers (Non-PCE)20
Fiscal Year PCE Payments $198,077
PCE Statistical Data
PCE Eligible kWh - Residential Customers 330,125 Average Annual PCE Payment per Eligible
Customer
$2,177
PCE Eligible kWh - Community Facility
Customers
190,224 Average PCE Payment per Eligible kWh $0.38
Total PCE Eligible kWh 520,349 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.72
Average Monthly PCE Eligible kWh per
Residential Customer
362 Last Reported PCE Level (per kWh)$0.44
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,057 Effective Residential Rate (per kWh)$0.27
Average Monthly PCE Eligible Community
Facility kWh per Person
55 PCE Eligible kWh vs Total kWh Sold 44.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,244,815 Fuel Used (Gallons)98,354
Non-Diesel kWh Generated 0 Fuel Cost $405,319
Purchased kWh 0 Average Price of Fuel $4.12
Total Purchased & Generated 1,244,815 Fuel Cost per kWh sold $0.35
Annual Non-Fuel Expenses $245,369
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.56
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 462,261 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
93.6%
Community Facility kWh Sold 261,848 Line Loss (%)3.5%
Other kWh Sold (Non-PCE)440,943 Fuel Efficiency (kWh per Gallon of Diesel)12.66
Total kWh Sold 1,165,052 PH Consumption as % of Generation 2.9%
Powerhouse (PH) Consumption kWh 35,975
Total kWh Sold & PH Consumption 1,201,027
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 19 of 187
Anaktuvuk Pass PCE
Utility: NORTH SLOPE BOROUGH
Reporting Period: 07/01/19..06/30/20
Community Population 376
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 102
Community Facility Customers 2
Other Customers (Non-PCE)59
Fiscal Year PCE Payments $3,020
PCE Statistical Data
PCE Eligible kWh - Residential Customers 260,017 Average Annual PCE Payment per Eligible
Customer
$29
PCE Eligible kWh - Community Facility
Customers
47,593 Average PCE Payment per Eligible kWh $0.01
Total PCE Eligible kWh 307,610 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.20
Average Monthly PCE Eligible kWh per
Residential Customer
212 Last Reported PCE Level (per kWh)$0.00
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,983 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per Person
11 PCE Eligible kWh vs Total kWh Sold 8.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 4,161,999 Fuel Used (Gallons)307,089
Non-Diesel kWh Generated 0 Fuel Cost $1,585,136
Purchased kWh 0 Average Price of Fuel $5.16
Total Purchased & Generated 4,161,999 Fuel Cost per kWh sold $0.42
Annual Non-Fuel Expenses $1,050,857
Non-Fuel Expense per kWh Sold $0.28
Total Expense per kWh Sold $0.70
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 790,947 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
90.3%
Community Facility kWh Sold 47,593 Line Loss (%)4.5%
Other kWh Sold (Non-PCE)2,920,203 Fuel Efficiency (kWh per Gallon of Diesel)13.55
Total kWh Sold 3,758,743 PH Consumption as % of Generation 5.2%
Powerhouse (PH) Consumption kWh 215,326
Total kWh Sold & PH Consumption 3,974,069
Comments
Residential PCE Level = $0.00 Per Eligible kWh
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 20 of 187
Angoon PCE
Utility: INSIDE PASSAGE ELECTRIC
Reporting Period: 07/01/19..06/30/20
Community Population 410
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 195
Community Facility Customers 8
Other Customers (Non-PCE)33
Fiscal Year PCE Payments $268,609
PCE Statistical Data
PCE Eligible kWh - Residential Customers 583,441 Average Annual PCE Payment per Eligible
Customer
$1,323
PCE Eligible kWh - Community Facility
Customers
186,588 Average PCE Payment per Eligible kWh $0.35
Total PCE Eligible kWh 770,029 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.60
Average Monthly PCE Eligible kWh per
Residential Customer
249 Last Reported PCE Level (per kWh)$0.33
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,944 Effective Residential Rate (per kWh)$0.27
Average Monthly PCE Eligible Community
Facility kWh per Person
38 PCE Eligible kWh vs Total kWh Sold 50.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,717,656 Fuel Used (Gallons)119,701
Non-Diesel kWh Generated 0 Fuel Cost $324,598
Purchased kWh 0 Average Price of Fuel $2.71
Total Purchased & Generated 1,717,656 Fuel Cost per kWh sold $0.21
Annual Non-Fuel Expenses $536,903
Non-Fuel Expense per kWh Sold $0.35
Total Expense per kWh Sold $0.57
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 752,753 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
88.4%
Community Facility kWh Sold 186,588 Line Loss (%)7.7%
Other kWh Sold (Non-PCE)578,939 Fuel Efficiency (kWh per Gallon of Diesel)14.35
Total kWh Sold 1,518,280 PH Consumption as % of Generation 3.9%
Powerhouse (PH) Consumption kWh 66,344
Total kWh Sold & PH Consumption 1,584,624
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 21 of 187
Aniak PCE
Utility: ANIAK LIGHT & POWER
Reporting Period: 07/01/19..06/30/20
Community Population 485
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 187
Community Facility Customers 14
Other Customers (Non-PCE)61
Fiscal Year PCE Payments $206,295
PCE Statistical Data
PCE Eligible kWh - Residential Customers 705,236 Average Annual PCE Payment per Eligible
Customer
$1,026
PCE Eligible kWh - Community Facility
Customers
58,766 Average PCE Payment per Eligible kWh $0.27
Total PCE Eligible kWh 764,002 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.58
Average Monthly PCE Eligible kWh per
Residential Customer
314 Last Reported PCE Level (per kWh)$0.27
Average Monthly PCE Eligible kWh per
Community Facility Customer
350 Effective Residential Rate (per kWh)$0.31
Average Monthly PCE Eligible Community
Facility kWh per Person
10 PCE Eligible kWh vs Total kWh Sold 36.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,515,810 Fuel Used (Gallons)198,875
Non-Diesel kWh Generated 0 Fuel Cost $567,195
Purchased kWh 0 Average Price of Fuel $2.85
Total Purchased & Generated 2,515,810 Fuel Cost per kWh sold $0.27
Annual Non-Fuel Expenses $495,356
Non-Fuel Expense per kWh Sold $0.23
Total Expense per kWh Sold $0.50
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 930,066 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
84.2%
Community Facility kWh Sold 58,766 Line Loss (%)14.4%
Other kWh Sold (Non-PCE)1,129,031 Fuel Efficiency (kWh per Gallon of Diesel)12.65
Total kWh Sold 2,117,863 PH Consumption as % of Generation 1.4%
Powerhouse (PH) Consumption kWh 36,115
Total kWh Sold & PH Consumption 2,153,978
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 22 of 187
Anvik PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 80
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 41
Community Facility Customers 11
Other Customers (Non-PCE)18
Fiscal Year PCE Payments $60,300
PCE Statistical Data
PCE Eligible kWh - Residential Customers 122,300 Average Annual PCE Payment per Eligible
Customer
$1,160
PCE Eligible kWh - Community Facility
Customers
54,604 Average PCE Payment per Eligible kWh $0.34
Total PCE Eligible kWh 176,904 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.60
Average Monthly PCE Eligible kWh per
Residential Customer
249 Last Reported PCE Level (per kWh)$0.33
Average Monthly PCE Eligible kWh per
Community Facility Customer
414 Effective Residential Rate (per kWh)$0.27
Average Monthly PCE Eligible Community
Facility kWh per Person
57 PCE Eligible kWh vs Total kWh Sold 47.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 414,681 Fuel Used (Gallons)32,737
Non-Diesel kWh Generated 0 Fuel Cost $93,884
Purchased kWh 0 Average Price of Fuel $2.87
Total Purchased & Generated 414,681 Fuel Cost per kWh sold $0.25
Annual Non-Fuel Expenses $78,985
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.46
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 139,315 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
90.4%
Community Facility kWh Sold 149,701 Line Loss (%)5.5%
Other kWh Sold (Non-PCE)86,017 Fuel Efficiency (kWh per Gallon of Diesel)12.67
Total kWh Sold 375,033 PH Consumption as % of Generation 4.1%
Powerhouse (PH) Consumption kWh 16,894
Total kWh Sold & PH Consumption 391,927
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 23 of 187
Arctic Village PCE
Utility: ARCTIC VILLAGE COUNCIL
Reporting Period: 07/01/19..06/30/20
Community Population 194
Last Reported Month June
No. of Monthly Payments Made 11
Residential Customers 100
Community Facility Customers 6
Other Customers (Non-PCE)13
Fiscal Year PCE Payments $170,084
PCE Statistical Data
PCE Eligible kWh - Residential Customers 176,717 Average Annual PCE Payment per Eligible
Customer
$1,605
PCE Eligible kWh - Community Facility
Customers
45,132 Average PCE Payment per Eligible kWh $0.77
Total PCE Eligible kWh 221,849 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.00
Average Monthly PCE Eligible kWh per
Residential Customer
161 Last Reported PCE Level (per kWh)$0.75
Average Monthly PCE Eligible kWh per
Community Facility Customer
684 Effective Residential Rate (per kWh)$0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
21 PCE Eligible kWh vs Total kWh Sold 48.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 618,952 Fuel Used (Gallons)50,917
Non-Diesel kWh Generated 0 Fuel Cost $272,702
Purchased kWh 0 Average Price of Fuel $5.36
Total Purchased & Generated 618,952 Fuel Cost per kWh sold $0.60
Annual Non-Fuel Expenses $0
Non-Fuel Expense per kWh Sold See Comments
Total Expense per kWh Sold $0.60
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 206,854 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
73.9%
Community Facility kWh Sold 45,132 Line Loss (%)26.1%
Other kWh Sold (Non-PCE)205,469 Fuel Efficiency (kWh per Gallon of Diesel)12.16
Total kWh Sold 457,455 PH Consumption as % of Generation 0.0%
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 457,455
Comments
Fuel Used & Fuel Costs = 11 Months; Pwrhse Cons. & Non-fuel Costs Not Reported
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 24 of 187
Atka PCE
Utility: CITY OF ATKA
Reporting Period: 07/01/19..06/30/20
Community Population 47
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 31
Community Facility Customers 8
Other Customers (Non-PCE)25
Fiscal Year PCE Payments $25,213
PCE Statistical Data
PCE Eligible kWh - Residential Customers 86,804 Average Annual PCE Payment per Eligible
Customer
$646
PCE Eligible kWh - Community Facility
Customers
25,765 Average PCE Payment per Eligible kWh $0.22
Total PCE Eligible kWh 112,569 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.63
Average Monthly PCE Eligible kWh per
Residential Customer
233 Last Reported PCE Level (per kWh)$0.23
Average Monthly PCE Eligible kWh per
Community Facility Customer
268 Effective Residential Rate (per kWh)$0.40
Average Monthly PCE Eligible Community
Facility kWh per Person
46 PCE Eligible kWh vs Total kWh Sold 37.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 35,085 Fuel Used (Gallons)4,023
Non-Diesel kWh Generated 312,600 Fuel Cost $18,210
Purchased kWh 0 Average Price of Fuel $4.53
Total Purchased & Generated 347,685 Fuel Cost per kWh sold $0.06
Annual Non-Fuel Expenses $31,200
Non-Fuel Expense per kWh Sold $0.10
Total Expense per kWh Sold $0.16
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 103,274 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
86.7%
Community Facility kWh Sold 26,243 Line Loss (%)3.6%
Other kWh Sold (Non-PCE)171,921 Fuel Efficiency (kWh per Gallon of Diesel)8.72
Total kWh Sold 301,438 PH Consumption as % of Generation 9.7%
Powerhouse (PH) Consumption kWh 33,788
Total kWh Sold & PH Consumption 335,226
Comments
kWh Generated = 11 Months; Fuel Used & Fuel Costs = 10 Months
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 25 of 187
Atmautluak PCE
Utility: ATMAUTLUAK TRIBAL UTILITIES
Reporting Period: 07/01/19..06/30/20
Community Population 328
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 74
Community Facility Customers 8
Other Customers (Non-PCE)14
Fiscal Year PCE Payments $153,716
PCE Statistical Data
PCE Eligible kWh - Residential Customers 309,035 Average Annual PCE Payment per Eligible
Customer
$1,875
PCE Eligible kWh - Community Facility
Customers
51,017 Average PCE Payment per Eligible kWh $0.43
Total PCE Eligible kWh 360,052 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.66
Average Monthly PCE Eligible kWh per
Residential Customer
348 Last Reported PCE Level (per kWh)$0.43
Average Monthly PCE Eligible kWh per
Community Facility Customer
531 Effective Residential Rate (per kWh)$0.23
Average Monthly PCE Eligible Community
Facility kWh per Person
13 PCE Eligible kWh vs Total kWh Sold 45.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 539,540 Fuel Used (Gallons)66,852
Non-Diesel kWh Generated 0 Fuel Cost $226,059
Purchased kWh 0 Average Price of Fuel $3.38
Total Purchased & Generated 539,540 Fuel Cost per kWh sold $0.28
Annual Non-Fuel Expenses $0
Non-Fuel Expense per kWh Sold See Comments
Total Expense per kWh Sold $0.28
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 346,222 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 51,017 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)400,526 Fuel Efficiency (kWh per Gallon of Diesel)8.07
Total kWh Sold 797,765 PH Consumption as % of Generation 4.3%
Powerhouse (PH) Consumption kWh 23,017
Total kWh Sold & PH Consumption 820,782
Comments
kWh Generated & Pwrhse Cons. = 7 Months; Non-fuel Cost Not Reported
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 26 of 187
Atqasuk PCE
Utility: NORTH SLOPE BOROUGH
Reporting Period: 07/01/19..06/30/20
Community Population 261
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 64
Community Facility Customers 2
Other Customers (Non-PCE)62
Fiscal Year PCE Payments $4,162
PCE Statistical Data
PCE Eligible kWh - Residential Customers 164,875 Average Annual PCE Payment per Eligible
Customer
$63
PCE Eligible kWh - Community Facility
Customers
57,452 Average PCE Payment per Eligible kWh $0.02
Total PCE Eligible kWh 222,327 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.22
Average Monthly PCE Eligible kWh per
Residential Customer
215 Last Reported PCE Level (per kWh)$0.00
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,394 Effective Residential Rate (per kWh)$0.22
Average Monthly PCE Eligible Community
Facility kWh per Person
18 PCE Eligible kWh vs Total kWh Sold 7.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)259,816
Non-Diesel kWh Generated 0 Fuel Cost $1,194,141
Purchased kWh 0 Average Price of Fuel $4.60
Total Purchased & Generated 0 Fuel Cost per kWh sold $0.39
Annual Non-Fuel Expenses $1,156,991
Non-Fuel Expense per kWh Sold $0.38
Total Expense per kWh Sold $0.76
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 652,876 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 57,452 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)2,372,947 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 3,083,275 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 3,083,275
Comments
Unable To Verify kWh's Gen'd & Pwrhse Consumption. Residential PCE Level = Zero
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 27 of 187
Beaver PCE
Utility: BEAVER JOINT UTILITIES
Reporting Period: 07/01/19..06/30/20
Community Population 75
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 42
Community Facility Customers 3
Other Customers (Non-PCE)17
Fiscal Year PCE Payments $85,668
PCE Statistical Data
PCE Eligible kWh - Residential Customers 82,706 Average Annual PCE Payment per Eligible
Customer
$1,904
PCE Eligible kWh - Community Facility
Customers
57,403 Average PCE Payment per Eligible kWh $0.61
Total PCE Eligible kWh 140,109 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.90
Average Monthly PCE Eligible kWh per
Residential Customer
164 Last Reported PCE Level (per kWh)$0.52
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,595 Effective Residential Rate (per kWh)$0.38
Average Monthly PCE Eligible Community
Facility kWh per Person
64 PCE Eligible kWh vs Total kWh Sold 51.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 324,516 Fuel Used (Gallons)29,766
Non-Diesel kWh Generated 0 Fuel Cost $111,876
Purchased kWh 0 Average Price of Fuel $3.76
Total Purchased & Generated 324,516 Fuel Cost per kWh sold $0.41
Annual Non-Fuel Expenses $87,527
Non-Fuel Expense per kWh Sold $0.32
Total Expense per kWh Sold $0.74
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 88,770 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
83.4%
Community Facility kWh Sold 61,159 Line Loss (%)14.8%
Other kWh Sold (Non-PCE)120,782 Fuel Efficiency (kWh per Gallon of Diesel)10.90
Total kWh Sold 270,711 PH Consumption as % of Generation 1.8%
Powerhouse (PH) Consumption kWh 5,808
Total kWh Sold & PH Consumption 276,519
Comments
Powerhouse Consumption = 4 Months
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 28 of 187
Bethel; Oscarville PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 6206
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 1,808
Community Facility Customers 47
Other Customers (Non-PCE)975
Fiscal Year PCE Payments $1,445,113
PCE Statistical Data
PCE Eligible kWh - Residential Customers 7,907,162 Average Annual PCE Payment per Eligible
Customer
$779
PCE Eligible kWh - Community Facility
Customers
2,545,266 Average PCE Payment per Eligible kWh $0.14
Total PCE Eligible kWh 10,452,428 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.38
Average Monthly PCE Eligible kWh per
Residential Customer
364 Last Reported PCE Level (per kWh)$0.12
Average Monthly PCE Eligible kWh per
Community Facility Customer
4,513 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
34 PCE Eligible kWh vs Total kWh Sold 24.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 42,701,000 Fuel Used (Gallons)3,101,629
Non-Diesel kWh Generated 1,629,425 Fuel Cost $11,462,739
Purchased kWh 0 Average Price of Fuel $3.70
Total Purchased & Generated 44,330,425 Fuel Cost per kWh sold $0.27
Annual Non-Fuel Expenses $8,826,722
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.48
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 10,773,166 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
94.5%
Community Facility kWh Sold 8,925,579 Line Loss (%)3.7%
Other kWh Sold (Non-PCE)22,211,938 Fuel Efficiency (kWh per Gallon of Diesel)13.77
Total kWh Sold 41,910,683 PH Consumption as % of Generation 1.7%
Powerhouse (PH) Consumption kWh 771,002
Total kWh Sold & PH Consumption 42,681,685
Comments
Sells Power To Napakiak Ircinraq Power Company For Resale
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 29 of 187
Bettles; Evansville PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/19..06/30/20
Community Population 19
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 31
Community Facility Customers 7
Other Customers (Non-PCE)28
Fiscal Year PCE Payments $41,680
PCE Statistical Data
PCE Eligible kWh - Residential Customers 78,100 Average Annual PCE Payment per Eligible
Customer
$1,097
PCE Eligible kWh - Community Facility
Customers
15,960 Average PCE Payment per Eligible kWh $0.44
Total PCE Eligible kWh 94,060 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.77
Average Monthly PCE Eligible kWh per
Residential Customer
210 Last Reported PCE Level (per kWh)$0.40
Average Monthly PCE Eligible kWh per
Community Facility Customer
190 Effective Residential Rate (per kWh)$0.37
Average Monthly PCE Eligible Community
Facility kWh per Person
70 PCE Eligible kWh vs Total kWh Sold 20.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 502,300 Fuel Used (Gallons)41,024
Non-Diesel kWh Generated 0 Fuel Cost $152,235
Purchased kWh 0 Average Price of Fuel $3.71
Total Purchased & Generated 502,300 Fuel Cost per kWh sold $0.34
Annual Non-Fuel Expenses $159,323
Non-Fuel Expense per kWh Sold $0.35
Total Expense per kWh Sold $0.69
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 97,305 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
90.4%
Community Facility kWh Sold 41,008 Line Loss (%)9.4%
Other kWh Sold (Non-PCE)315,654 Fuel Efficiency (kWh per Gallon of Diesel)12.24
Total kWh Sold 453,967 PH Consumption as % of Generation 0.2%
Powerhouse (PH) Consumption kWh 896
Total kWh Sold & PH Consumption 454,863
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 30 of 187
Birch Creek PCE
Utility: BIRCH CREEK ELECTRIC COMPANY
Reporting Period: 07/01/19..06/30/20
Community Population 18
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 16
Community Facility Customers 4
Other Customers (Non-PCE)5
Fiscal Year PCE Payments $28,694
PCE Statistical Data
PCE Eligible kWh - Residential Customers 23,202 Average Annual PCE Payment per Eligible
Customer
$1,435
PCE Eligible kWh - Community Facility
Customers
14,181 Average PCE Payment per Eligible kWh $0.77
Total PCE Eligible kWh 37,383 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.15
Average Monthly PCE Eligible kWh per
Residential Customer
121 Last Reported PCE Level (per kWh)$0.77
Average Monthly PCE Eligible kWh per
Community Facility Customer
295 Effective Residential Rate (per kWh)$0.38
Average Monthly PCE Eligible Community
Facility kWh per Person
66 PCE Eligible kWh vs Total kWh Sold 40.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 104,550 Fuel Used (Gallons)14,733
Non-Diesel kWh Generated 0 Fuel Cost $59,214
Purchased kWh 0 Average Price of Fuel $4.02
Total Purchased & Generated 104,550 Fuel Cost per kWh sold $0.65
Annual Non-Fuel Expenses $58,161
Non-Fuel Expense per kWh Sold $0.63
Total Expense per kWh Sold $1.28
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 25,207 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
87.7%
Community Facility kWh Sold 18,613 Line Loss (%)8.4%
Other kWh Sold (Non-PCE)47,903 Fuel Efficiency (kWh per Gallon of Diesel)7.10
Total kWh Sold 91,723 PH Consumption as % of Generation 3.8%
Powerhouse (PH) Consumption kWh 4,018
Total kWh Sold & PH Consumption 95,741
Comments
Non-fuel Costs = 11 Months
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 31 of 187
Brevig Mission PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 462
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 86
Community Facility Customers 8
Other Customers (Non-PCE)27
Fiscal Year PCE Payments $169,609
PCE Statistical Data
PCE Eligible kWh - Residential Customers 423,253 Average Annual PCE Payment per Eligible
Customer
$1,804
PCE Eligible kWh - Community Facility
Customers
175,177 Average PCE Payment per Eligible kWh $0.28
Total PCE Eligible kWh 598,430 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.55
Average Monthly PCE Eligible kWh per
Residential Customer
410 Last Reported PCE Level (per kWh)$0.29
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,825 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
32 PCE Eligible kWh vs Total kWh Sold 50.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,274,822 Fuel Used (Gallons)91,258
Non-Diesel kWh Generated 0 Fuel Cost $276,170
Purchased kWh 0 Average Price of Fuel $3.03
Total Purchased & Generated 1,274,822 Fuel Cost per kWh sold $0.23
Annual Non-Fuel Expenses $250,794
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.44
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 539,710 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
93.4%
Community Facility kWh Sold 299,271 Line Loss (%)2.1%
Other kWh Sold (Non-PCE)351,830 Fuel Efficiency (kWh per Gallon of Diesel)13.97
Total kWh Sold 1,190,811 PH Consumption as % of Generation 4.5%
Powerhouse (PH) Consumption kWh 57,801
Total kWh Sold & PH Consumption 1,248,612
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 32 of 187
Buckland PCE
Utility: CITY OF BUCKLAND
Reporting Period: 07/01/19..06/30/20
Community Population 511
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 101
Community Facility Customers 12
Other Customers (Non-PCE)27
Fiscal Year PCE Payments $102,287
PCE Statistical Data
PCE Eligible kWh - Residential Customers 498,335 Average Annual PCE Payment per Eligible
Customer
$905
PCE Eligible kWh - Community Facility
Customers
119,987 Average PCE Payment per Eligible kWh $0.17
Total PCE Eligible kWh 618,322 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.47
Average Monthly PCE Eligible kWh per
Residential Customer
411 Last Reported PCE Level (per kWh)$0.21
Average Monthly PCE Eligible kWh per
Community Facility Customer
833 Effective Residential Rate (per kWh)$0.27
Average Monthly PCE Eligible Community
Facility kWh per Person
20 PCE Eligible kWh vs Total kWh Sold 37.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,398,202 Fuel Used (Gallons)125,304
Non-Diesel kWh Generated 228,419 Fuel Cost $423,644
Purchased kWh 0 Average Price of Fuel $3.38
Total Purchased & Generated 1,626,621 Fuel Cost per kWh sold $0.26
Annual Non-Fuel Expenses $43,494
Non-Fuel Expense per kWh Sold $0.03
Total Expense per kWh Sold $0.28
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 735,522 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 119,987 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)800,924 Fuel Efficiency (kWh per Gallon of Diesel)11.16
Total kWh Sold 1,656,433 PH Consumption as % of Generation 1.9%
Powerhouse (PH) Consumption kWh 31,422
Total kWh Sold & PH Consumption 1,687,855
Comments
kWh Generated & Non-fuel Costs = 11 Months; Pwrhse Cons. = 8 Months
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 33 of 187
Central PCE
Utility: GOLD COUNTRY ENERGY
Reporting Period: 07/01/19..06/30/20
Community Population 81
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 124
Community Facility Customers 1
Other Customers (Non-PCE)17
Fiscal Year PCE Payments $80,613
PCE Statistical Data
PCE Eligible kWh - Residential Customers 213,089 Average Annual PCE Payment per Eligible
Customer
$645
PCE Eligible kWh - Community Facility
Customers
4,542 Average PCE Payment per Eligible kWh $0.37
Total PCE Eligible kWh 217,631 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.62
Average Monthly PCE Eligible kWh per
Residential Customer
143 Last Reported PCE Level (per kWh)$0.28
Average Monthly PCE Eligible kWh per
Community Facility Customer
379 Effective Residential Rate (per kWh)$0.33
Average Monthly PCE Eligible Community
Facility kWh per Person
5 PCE Eligible kWh vs Total kWh Sold 64.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 440,588 Fuel Used (Gallons)41,431
Non-Diesel kWh Generated 0 Fuel Cost $109,706
Purchased kWh 0 Average Price of Fuel $2.65
Total Purchased & Generated 440,588 Fuel Cost per kWh sold $0.33
Annual Non-Fuel Expenses $91,016
Non-Fuel Expense per kWh Sold $0.27
Total Expense per kWh Sold $0.60
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 241,101 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
76.5%
Community Facility kWh Sold 4,542 Line Loss (%)19.9%
Other kWh Sold (Non-PCE)91,306 Fuel Efficiency (kWh per Gallon of Diesel)10.63
Total kWh Sold 336,949 PH Consumption as % of Generation 3.7%
Powerhouse (PH) Consumption kWh 16,152
Total kWh Sold & PH Consumption 353,101
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 34 of 187
Chalkyitsik PCE
Utility: CHALKYITSIK VILLAGE COUNCIL
Reporting Period: 07/01/19..06/30/20
Community Population 71
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 46
Community Facility Customers 8
Other Customers (Non-PCE)13
Fiscal Year PCE Payments $53,567
PCE Statistical Data
PCE Eligible kWh - Residential Customers 46,105 Average Annual PCE Payment per Eligible
Customer
$992
PCE Eligible kWh - Community Facility
Customers
48,424 Average PCE Payment per Eligible kWh $0.57
Total PCE Eligible kWh 94,529 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.95
Average Monthly PCE Eligible kWh per
Residential Customer
84 Last Reported PCE Level (per kWh)$0.58
Average Monthly PCE Eligible kWh per
Community Facility Customer
504 Effective Residential Rate (per kWh)$0.37
Average Monthly PCE Eligible Community
Facility kWh per Person
57 PCE Eligible kWh vs Total kWh Sold 45.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 284,730 Fuel Used (Gallons)27,115
Non-Diesel kWh Generated 0 Fuel Cost $126,099
Purchased kWh 0 Average Price of Fuel $4.65
Total Purchased & Generated 284,730 Fuel Cost per kWh sold $0.61
Annual Non-Fuel Expenses $37,478
Non-Fuel Expense per kWh Sold $0.18
Total Expense per kWh Sold $0.79
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 46,731 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
72.8%
Community Facility kWh Sold 62,649 Line Loss (%)18.1%
Other kWh Sold (Non-PCE)98,030 Fuel Efficiency (kWh per Gallon of Diesel)10.50
Total kWh Sold 207,410 PH Consumption as % of Generation 9.0%
Powerhouse (PH) Consumption kWh 25,659
Total kWh Sold & PH Consumption 233,069
Comments
Non-fuel Cost = 8 Months
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 35 of 187
Chefornak PCE
Utility: NATERKAQ LIGHT PLANT
Reporting Period: 07/01/19..06/30/20
Community Population 442
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 105
Community Facility Customers 17
Other Customers (Non-PCE)33
Fiscal Year PCE Payments $126,037
PCE Statistical Data
PCE Eligible kWh - Residential Customers 458,950 Average Annual PCE Payment per Eligible
Customer
$1,033
PCE Eligible kWh - Community Facility
Customers
63,486 Average PCE Payment per Eligible kWh $0.24
Total PCE Eligible kWh 522,436 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.55
Average Monthly PCE Eligible kWh per
Residential Customer
364 Last Reported PCE Level (per kWh)$0.24
Average Monthly PCE Eligible kWh per
Community Facility Customer
311 Effective Residential Rate (per kWh)$0.31
Average Monthly PCE Eligible Community
Facility kWh per Person
12 PCE Eligible kWh vs Total kWh Sold 39.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,479,784 Fuel Used (Gallons)114,334
Non-Diesel kWh Generated 0 Fuel Cost $344,424
Purchased kWh 0 Average Price of Fuel $3.01
Total Purchased & Generated 1,479,784 Fuel Cost per kWh sold $0.26
Annual Non-Fuel Expenses $0
Non-Fuel Expense per kWh Sold See Comments
Total Expense per kWh Sold $0.26
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 550,200 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
89.2%
Community Facility kWh Sold 65,281 Line Loss (%)7.6%
Other kWh Sold (Non-PCE)704,241 Fuel Efficiency (kWh per Gallon of Diesel)12.94
Total kWh Sold 1,319,722 PH Consumption as % of Generation 3.2%
Powerhouse (PH) Consumption kWh 47,740
Total kWh Sold & PH Consumption 1,367,462
Comments
Non-Fuel Costs Not Reported
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 36 of 187
Chenega Bay PCE
Utility: NATIVE VILLAGE OF CHENEGA
Reporting Period: 07/01/19..06/30/20
Community Population 56
Last Reported Month June
No. of Monthly Payments Made 11
Residential Customers 26
Community Facility Customers 10
Other Customers (Non-PCE)19
Fiscal Year PCE Payments $42,059
PCE Statistical Data
PCE Eligible kWh - Residential Customers 72,012 Average Annual PCE Payment per Eligible
Customer
$1,168
PCE Eligible kWh - Community Facility
Customers
46,744 Average PCE Payment per Eligible kWh $0.35
Total PCE Eligible kWh 118,756 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.67
Average Monthly PCE Eligible kWh per
Residential Customer
252 Last Reported PCE Level (per kWh)$0.36
Average Monthly PCE Eligible kWh per
Community Facility Customer
425 Effective Residential Rate (per kWh)$0.31
Average Monthly PCE Eligible Community
Facility kWh per Person
76 PCE Eligible kWh vs Total kWh Sold 56.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 78,282 Fuel Used (Gallons)15,706
Non-Diesel kWh Generated 0 Fuel Cost $67,667
Purchased kWh 0 Average Price of Fuel $4.31
Total Purchased & Generated 78,282 Fuel Cost per kWh sold $0.32
Annual Non-Fuel Expenses $86,950
Non-Fuel Expense per kWh Sold $0.41
Total Expense per kWh Sold $0.73
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 85,927 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 61,015 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)63,667 Fuel Efficiency (kWh per Gallon of Diesel)4.98
Total kWh Sold 210,609 PH Consumption as % of Generation 6.9%
Powerhouse (PH) Consumption kWh 5,380
Total kWh Sold & PH Consumption 215,989
Comments
Utility Unable To Verify Plant Meter Readings
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 37 of 187
Chevak PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 1074
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 208
Community Facility Customers 10
Other Customers (Non-PCE)41
Fiscal Year PCE Payments $293,937
PCE Statistical Data
PCE Eligible kWh - Residential Customers 847,668 Average Annual PCE Payment per Eligible
Customer
$1,348
PCE Eligible kWh - Community Facility
Customers
316,009 Average PCE Payment per Eligible kWh $0.25
Total PCE Eligible kWh 1,163,677 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.52
Average Monthly PCE Eligible kWh per
Residential Customer
340 Last Reported PCE Level (per kWh)$0.23
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,633 Effective Residential Rate (per kWh)$0.29
Average Monthly PCE Eligible Community
Facility kWh per Person
25 PCE Eligible kWh vs Total kWh Sold 48.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,758,458 Fuel Used (Gallons)129,283
Non-Diesel kWh Generated 822,293 Fuel Cost $394,281
Purchased kWh 0 Average Price of Fuel $3.05
Total Purchased & Generated 2,580,751 Fuel Cost per kWh sold $0.16
Annual Non-Fuel Expenses $503,654
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.38
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,012,268 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
92.7%
Community Facility kWh Sold 532,073 Line Loss (%)3.3%
Other kWh Sold (Non-PCE)847,090 Fuel Efficiency (kWh per Gallon of Diesel)13.60
Total kWh Sold 2,391,431 PH Consumption as % of Generation 4.0%
Powerhouse (PH) Consumption kWh 103,737
Total kWh Sold & PH Consumption 2,495,168
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 38 of 187
Chignik Lagoon PCE
Utility: CHIGNIK LAGOON POWER UTILITY
Reporting Period: 07/01/19..06/30/20
Community Population 83
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 65
Community Facility Customers 7
Other Customers (Non-PCE)11
Fiscal Year PCE Payments $47,164
PCE Statistical Data
PCE Eligible kWh - Residential Customers 130,197 Average Annual PCE Payment per Eligible
Customer
$655
PCE Eligible kWh - Community Facility
Customers
41,910 Average PCE Payment per Eligible kWh $0.27
Total PCE Eligible kWh 172,107 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.58
Average Monthly PCE Eligible kWh per
Residential Customer
167 Last Reported PCE Level (per kWh)$0.25
Average Monthly PCE Eligible kWh per
Community Facility Customer
499 Effective Residential Rate (per kWh)$0.33
Average Monthly PCE Eligible Community
Facility kWh per Person
42 PCE Eligible kWh vs Total kWh Sold 42.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 172,147 Fuel Used (Gallons)19,829
Non-Diesel kWh Generated 252,428 Fuel Cost $61,154
Purchased kWh 0 Average Price of Fuel $3.08
Total Purchased & Generated 424,575 Fuel Cost per kWh sold $0.15
Annual Non-Fuel Expenses $114,274
Non-Fuel Expense per kWh Sold $0.28
Total Expense per kWh Sold $0.44
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 231,240 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
94.8%
Community Facility kWh Sold 41,957 Line Loss (%)0.2%
Other kWh Sold (Non-PCE)129,159 Fuel Efficiency (kWh per Gallon of Diesel)8.68
Total kWh Sold 402,356 PH Consumption as % of Generation 5.1%
Powerhouse (PH) Consumption kWh 21,552
Total kWh Sold & PH Consumption 423,908
Comments
kWh's Generated & Powerhouse Consumption = 10 Months
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 39 of 187
Chignik Lake PCE
Utility: CHIGNIK LAKE ELECTRIC UTILITY
Reporting Period: 07/01/19..06/30/20
Community Population 68
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 43
Community Facility Customers 9
Other Customers (Non-PCE)6
Fiscal Year PCE Payments $44,202
PCE Statistical Data
PCE Eligible kWh - Residential Customers 91,175 Average Annual PCE Payment per Eligible
Customer
$850
PCE Eligible kWh - Community Facility
Customers
27,431 Average PCE Payment per Eligible kWh $0.37
Total PCE Eligible kWh 118,606 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.70
Average Monthly PCE Eligible kWh per
Residential Customer
177 Last Reported PCE Level (per kWh)$0.34
Average Monthly PCE Eligible kWh per
Community Facility Customer
254 Effective Residential Rate (per kWh)$0.36
Average Monthly PCE Eligible Community
Facility kWh per Person
34 PCE Eligible kWh vs Total kWh Sold 43.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 319,715 Fuel Used (Gallons)31,794
Non-Diesel kWh Generated 0 Fuel Cost $112,010
Purchased kWh 0 Average Price of Fuel $3.52
Total Purchased & Generated 319,715 Fuel Cost per kWh sold $0.41
Annual Non-Fuel Expenses $30,477
Non-Fuel Expense per kWh Sold $0.11
Total Expense per kWh Sold $0.52
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 123,706 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
86.3%
Community Facility kWh Sold 27,916 Line Loss (%)11.2%
Other kWh Sold (Non-PCE)124,169 Fuel Efficiency (kWh per Gallon of Diesel)10.06
Total kWh Sold 275,791 PH Consumption as % of Generation 2.6%
Powerhouse (PH) Consumption kWh 8,190
Total kWh Sold & PH Consumption 283,981
Comments
Non-fuel Costs = 9 Months
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 40 of 187
Chignik PCE
Utility: CITY OF CHIGNIK
Reporting Period: 07/01/19..06/30/20
Community Population 98
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 55
Community Facility Customers 10
Other Customers (Non-PCE)74
Fiscal Year PCE Payments $43,153
PCE Statistical Data
PCE Eligible kWh - Residential Customers 130,507 Average Annual PCE Payment per Eligible
Customer
$664
PCE Eligible kWh - Community Facility
Customers
61,282 Average PCE Payment per Eligible kWh $0.23
Total PCE Eligible kWh 191,789 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.42
Average Monthly PCE Eligible kWh per
Residential Customer
198 Last Reported PCE Level (per kWh)$0.23
Average Monthly PCE Eligible kWh per
Community Facility Customer
511 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per Person
52 PCE Eligible kWh vs Total kWh Sold 22.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,145,974 Fuel Used (Gallons)53,577
Non-Diesel kWh Generated 0 Fuel Cost $150,224
Purchased kWh 0 Average Price of Fuel $2.80
Total Purchased & Generated 1,145,974 Fuel Cost per kWh sold $0.18
Annual Non-Fuel Expenses $74,299
Non-Fuel Expense per kWh Sold $0.09
Total Expense per kWh Sold $0.26
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 328,722 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
74.3%
Community Facility kWh Sold 86,606 Line Loss (%)15.0%
Other kWh Sold (Non-PCE)435,721 Fuel Efficiency (kWh per Gallon of Diesel)21.39
Total kWh Sold 851,049 PH Consumption as % of Generation 10.7%
Powerhouse (PH) Consumption kWh 122,895
Total kWh Sold & PH Consumption 973,944
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 41 of 187
Chilkat Valley PCE
Utility: INSIDE PASSAGE ELECTRIC
Reporting Period: 07/01/19..06/30/20
Community Population 756
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 211
Community Facility Customers 1
Other Customers (Non-PCE)41
Fiscal Year PCE Payments $204,882
PCE Statistical Data
PCE Eligible kWh - Residential Customers 569,144 Average Annual PCE Payment per Eligible
Customer
$966
PCE Eligible kWh - Community Facility
Customers
1,495 Average PCE Payment per Eligible kWh $0.36
Total PCE Eligible kWh 570,639 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.60
Average Monthly PCE Eligible kWh per
Residential Customer
225 Last Reported PCE Level (per kWh)$0.33
Average Monthly PCE Eligible kWh per
Community Facility Customer
125 Effective Residential Rate (per kWh)$0.27
Average Monthly PCE Eligible Community
Facility kWh per Person
0 PCE Eligible kWh vs Total kWh Sold 51.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 764,880 Fuel Cost $0
Purchased kWh 1,062,540 Average Price of Fuel $0.00
Total Purchased & Generated 1,827,420 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $585,282
Non-Fuel Expense per kWh Sold $0.53
Total Expense per kWh Sold $0.53
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 666,567 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
60.2%
Community Facility kWh Sold 1,495 Line Loss (%)36.4%
Other kWh Sold (Non-PCE)431,150 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 1,099,212 PH Consumption as % of Generation 3.4%
Powerhouse (PH) Consumption kWh 62,571
Total kWh Sold & PH Consumption 1,161,783
Comments
Provides Power To Klukwan Facility For Sales To Its Customers
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 42 of 187
Chistochina PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/19..06/30/20
Community Population 88
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 47
Community Facility Customers 2
Other Customers (Non-PCE)23
Fiscal Year PCE Payments $48,256
PCE Statistical Data
PCE Eligible kWh - Residential Customers 141,133 Average Annual PCE Payment per Eligible
Customer
$985
PCE Eligible kWh - Community Facility
Customers
20,756 Average PCE Payment per Eligible kWh $0.30
Total PCE Eligible kWh 161,889 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.56
Average Monthly PCE Eligible kWh per
Residential Customer
250 Last Reported PCE Level (per kWh)$0.26
Average Monthly PCE Eligible kWh per
Community Facility Customer
865 Effective Residential Rate (per kWh)$0.30
Average Monthly PCE Eligible Community
Facility kWh per Person
20 PCE Eligible kWh vs Total kWh Sold 42.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $0
Non-Fuel Expense per kWh Sold See Comments
Total Expense per kWh Sold $0.00
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 194,763 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 20,756 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)162,853 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 378,372 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 1,681
Total kWh Sold & PH Consumption 380,053
Comments
See Slana For Power Generation
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 43 of 187
Chitina PCE
Utility: CHITINA ELECTRIC INC.
Reporting Period: 07/01/19..06/30/20
Community Population 93
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 40
Community Facility Customers 2
Other Customers (Non-PCE)40
Fiscal Year PCE Payments $31,391
PCE Statistical Data
PCE Eligible kWh - Residential Customers 88,945 Average Annual PCE Payment per Eligible
Customer
$747
PCE Eligible kWh - Community Facility
Customers
10,149 Average PCE Payment per Eligible kWh $0.32
Total PCE Eligible kWh 99,094 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.70
Average Monthly PCE Eligible kWh per
Residential Customer
185 Last Reported PCE Level (per kWh)$0.26
Average Monthly PCE Eligible kWh per
Community Facility Customer
423 Effective Residential Rate (per kWh)$0.44
Average Monthly PCE Eligible Community
Facility kWh per Person
9 PCE Eligible kWh vs Total kWh Sold 27.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 432,522 Fuel Used (Gallons)37,585
Non-Diesel kWh Generated 0 Fuel Cost $105,896
Purchased kWh 0 Average Price of Fuel $2.82
Total Purchased & Generated 432,522 Fuel Cost per kWh sold $0.29
Annual Non-Fuel Expenses $157,684
Non-Fuel Expense per kWh Sold $0.43
Total Expense per kWh Sold $0.72
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 99,389 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
84.9%
Community Facility kWh Sold 10,149 Line Loss (%)5.4%
Other kWh Sold (Non-PCE)257,626 Fuel Efficiency (kWh per Gallon of Diesel)11.51
Total kWh Sold 367,164 PH Consumption as % of Generation 9.7%
Powerhouse (PH) Consumption kWh 41,927
Total kWh Sold & PH Consumption 409,091
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 44 of 187
Chuathbaluk PCE
Utility: MIDDLE KUSKOKWIM ELECTRIC COOPERATIVE INC
Reporting Period: 07/01/19..06/30/20
Community Population 111
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 31
Community Facility Customers 10
Other Customers (Non-PCE)6
Fiscal Year PCE Payments $101,815
PCE Statistical Data
PCE Eligible kWh - Residential Customers 80,237 Average Annual PCE Payment per Eligible
Customer
$2,483
PCE Eligible kWh - Community Facility
Customers
53,302 Average PCE Payment per Eligible kWh $0.76
Total PCE Eligible kWh 133,539 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.29
Average Monthly PCE Eligible kWh per
Residential Customer
216 Last Reported PCE Level (per kWh)$0.77
Average Monthly PCE Eligible kWh per
Community Facility Customer
444 Effective Residential Rate (per kWh)$0.52
Average Monthly PCE Eligible Community
Facility kWh per Person
40 PCE Eligible kWh vs Total kWh Sold 62.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 246,493 Fuel Used (Gallons)22,740
Non-Diesel kWh Generated 0 Fuel Cost $73,781
Purchased kWh 0 Average Price of Fuel $3.24
Total Purchased & Generated 246,493 Fuel Cost per kWh sold $0.35
Annual Non-Fuel Expenses $206,806
Non-Fuel Expense per kWh Sold $0.97
Total Expense per kWh Sold $1.32
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 82,702 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
86.3%
Community Facility kWh Sold 53,449 Line Loss (%)9.4%
Other kWh Sold (Non-PCE)76,482 Fuel Efficiency (kWh per Gallon of Diesel)10.84
Total kWh Sold 212,633 PH Consumption as % of Generation 4.4%
Powerhouse (PH) Consumption kWh 10,730
Total kWh Sold & PH Consumption 223,363
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 45 of 187
Circle PCE
Utility: CIRCLE ELECTRIC LLC
Reporting Period: 07/01/19..06/30/20
Community Population 81
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 42
Community Facility Customers 7
Other Customers (Non-PCE)9
Fiscal Year PCE Payments $86,589
PCE Statistical Data
PCE Eligible kWh - Residential Customers 100,850 Average Annual PCE Payment per Eligible
Customer
$1,767
PCE Eligible kWh - Community Facility
Customers
66,805 Average PCE Payment per Eligible kWh $0.52
Total PCE Eligible kWh 167,655 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.76
Average Monthly PCE Eligible kWh per
Residential Customer
200 Last Reported PCE Level (per kWh)$0.47
Average Monthly PCE Eligible kWh per
Community Facility Customer
795 Effective Residential Rate (per kWh)$0.30
Average Monthly PCE Eligible Community
Facility kWh per Person
69 PCE Eligible kWh vs Total kWh Sold 44.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 411,760 Fuel Used (Gallons)38,987
Non-Diesel kWh Generated 0 Fuel Cost $106,732
Purchased kWh 0 Average Price of Fuel $2.74
Total Purchased & Generated 411,760 Fuel Cost per kWh sold $0.28
Annual Non-Fuel Expenses $148,198
Non-Fuel Expense per kWh Sold $0.40
Total Expense per kWh Sold $0.68
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 138,586 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
91.0%
Community Facility kWh Sold 94,637 Line Loss (%)8.0%
Other kWh Sold (Non-PCE)141,624 Fuel Efficiency (kWh per Gallon of Diesel)10.56
Total kWh Sold 374,847 PH Consumption as % of Generation 1.0%
Powerhouse (PH) Consumption kWh 3,975
Total kWh Sold & PH Consumption 378,822
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 46 of 187
Clark's Point PCE
Utility: CLARKS POINT VILLAGE COUNCIL
Reporting Period: 07/01/19..06/30/20
Community Population 55
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 49
Community Facility Customers 6
Other Customers (Non-PCE)12
Fiscal Year PCE Payments $81,344
PCE Statistical Data
PCE Eligible kWh - Residential Customers 111,836 Average Annual PCE Payment per Eligible
Customer
$1,479
PCE Eligible kWh - Community Facility
Customers
9,725 Average PCE Payment per Eligible kWh $0.67
Total PCE Eligible kWh 121,561 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.10
Average Monthly PCE Eligible kWh per
Residential Customer
190 Last Reported PCE Level (per kWh)$0.66
Average Monthly PCE Eligible kWh per
Community Facility Customer
135 Effective Residential Rate (per kWh)$0.44
Average Monthly PCE Eligible Community
Facility kWh per Person
15 PCE Eligible kWh vs Total kWh Sold 47.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 338,280 Fuel Used (Gallons)32,497
Non-Diesel kWh Generated 0 Fuel Cost $117,402
Purchased kWh 0 Average Price of Fuel $3.61
Total Purchased & Generated 338,280 Fuel Cost per kWh sold $0.46
Annual Non-Fuel Expenses $0
Non-Fuel Expense per kWh Sold See Comments
Total Expense per kWh Sold $0.46
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 134,626 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
76.3%
Community Facility kWh Sold 10,940 Line Loss (%)21.3%
Other kWh Sold (Non-PCE)112,406 Fuel Efficiency (kWh per Gallon of Diesel)10.41
Total kWh Sold 257,972 PH Consumption as % of Generation 2.4%
Powerhouse (PH) Consumption kWh 8,265
Total kWh Sold & PH Consumption 266,237
Comments
Non-fuel Costs Not Reported; Powerhouse Consumption = 8 Months
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 47 of 187
Coffman Cove PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/19..06/30/20
Community Population 168
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 183
Community Facility Customers 14
Other Customers (Non-PCE)46
Fiscal Year PCE Payments $9,215
PCE Statistical Data
PCE Eligible kWh - Residential Customers 532,542 Average Annual PCE Payment per Eligible
Customer
$47
PCE Eligible kWh - Community Facility
Customers
95,793 Average PCE Payment per Eligible kWh $0.01
Total PCE Eligible kWh 628,335 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.27
Average Monthly PCE Eligible kWh per
Residential Customer
243 Last Reported PCE Level (per kWh)$0.02
Average Monthly PCE Eligible kWh per
Community Facility Customer
570 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
48 PCE Eligible kWh vs Total kWh Sold 53.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $0
Non-Fuel Expense per kWh Sold See Comments
Total Expense per kWh Sold $0.00
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 814,033 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 95,793 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)263,062 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 1,172,888 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 44,328
Total kWh Sold & PH Consumption 1,217,216
Comments
See Craig For Power Generation
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 48 of 187
Cold Bay PCE
Utility: G & K INC.
Reporting Period: 07/01/19..06/30/20
Community Population 63
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 40
Community Facility Customers 4
Other Customers (Non-PCE)80
Fiscal Year PCE Payments $52,041
PCE Statistical Data
PCE Eligible kWh - Residential Customers 53,173 Average Annual PCE Payment per Eligible
Customer
$1,183
PCE Eligible kWh - Community Facility
Customers
52,920 Average PCE Payment per Eligible kWh $0.49
Total PCE Eligible kWh 106,093 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.71
Average Monthly PCE Eligible kWh per
Residential Customer
111 Last Reported PCE Level (per kWh)$0.52
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,103 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per Person
70 PCE Eligible kWh vs Total kWh Sold 5.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,370,511 Fuel Used (Gallons)182,453
Non-Diesel kWh Generated 0 Fuel Cost $867,118
Purchased kWh 0 Average Price of Fuel $4.75
Total Purchased & Generated 2,370,511 Fuel Cost per kWh sold $0.45
Annual Non-Fuel Expenses $0
Non-Fuel Expense per kWh Sold See Comments
Total Expense per kWh Sold $0.45
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 154,806 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
81.3%
Community Facility kWh Sold 70,133 Line Loss (%)11.3%
Other kWh Sold (Non-PCE)1,702,611 Fuel Efficiency (kWh per Gallon of Diesel)12.99
Total kWh Sold 1,927,550 PH Consumption as % of Generation 7.4%
Powerhouse (PH) Consumption kWh 174,964
Total kWh Sold & PH Consumption 2,102,514
Comments
Unable To Verify kWh Generated or Powerhouse Consumption As Reported
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 49 of 187
Cordova PCE
Utility: CORDOVA ELECTRIC
Reporting Period: 07/01/19..06/30/20
Community Population 2495
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 969
Community Facility Customers 48
Other Customers (Non-PCE)689
Fiscal Year PCE Payments $394,291
PCE Statistical Data
PCE Eligible kWh - Residential Customers 3,265,425 Average Annual PCE Payment per Eligible
Customer
$388
PCE Eligible kWh - Community Facility
Customers
1,873,284 Average PCE Payment per Eligible kWh $0.08
Total PCE Eligible kWh 5,138,709 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.35
Average Monthly PCE Eligible kWh per
Residential Customer
281 Last Reported PCE Level (per kWh)$0.07
Average Monthly PCE Eligible kWh per
Community Facility Customer
3,252 Effective Residential Rate (per kWh)$0.28
Average Monthly PCE Eligible Community
Facility kWh per Person
63 PCE Eligible kWh vs Total kWh Sold 21.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 7,914,234 Fuel Used (Gallons)605,537
Non-Diesel kWh Generated 16,386,205 Fuel Cost $1,598,813
Purchased kWh 0 Average Price of Fuel $2.64
Total Purchased & Generated 24,300,439 Fuel Cost per kWh sold $0.07
Annual Non-Fuel Expenses $5,112,465
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.28
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 4,789,631 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
97.9%
Community Facility kWh Sold 1,957,249 Line Loss (%)0.7%
Other kWh Sold (Non-PCE)17,035,810 Fuel Efficiency (kWh per Gallon of Diesel)13.07
Total kWh Sold 23,782,690 PH Consumption as % of Generation 1.4%
Powerhouse (PH) Consumption kWh 340,732
Total kWh Sold & PH Consumption 24,123,422
Comments
kWh's Generated & Powerhouse Consumption = 11 Months
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 50 of 187
Craig PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/19..06/30/20
Community Population 1095
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 681
Community Facility Customers 44
Other Customers (Non-PCE)331
Fiscal Year PCE Payments $50,393
PCE Statistical Data
PCE Eligible kWh - Residential Customers 2,456,728 Average Annual PCE Payment per Eligible
Customer
$70
PCE Eligible kWh - Community Facility
Customers
907,571 Average PCE Payment per Eligible kWh $0.01
Total PCE Eligible kWh 3,364,299 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.27
Average Monthly PCE Eligible kWh per
Residential Customer
301 Last Reported PCE Level (per kWh)$0.02
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,719 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
69 PCE Eligible kWh vs Total kWh Sold 34.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 3,695,744 Fuel Used (Gallons)264,291
Non-Diesel kWh Generated 0 Fuel Cost $699,708
Purchased kWh 25,575,762 Average Price of Fuel $2.65
Total Purchased & Generated 29,271,506 Fuel Cost per kWh sold $0.07
Annual Non-Fuel Expenses $2,617,072
Non-Fuel Expense per kWh Sold $0.26
Total Expense per kWh Sold $0.34
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 3,482,531 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
33.8%
Community Facility kWh Sold 1,168,034 Line Loss (%)65.6%
Other kWh Sold (Non-PCE)5,233,110 Fuel Efficiency (kWh per Gallon of Diesel)13.98
Total kWh Sold 9,883,675 PH Consumption as % of Generation 0.6%
Powerhouse (PH) Consumption kWh 175,710
Total kWh Sold & PH Consumption 10,059,385
Comments
Supplies Power To Coffman Cove, Hollis, Hydaburg, Klawock, Thorne Bay/Kasaan
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 51 of 187
Crooked Creek PCE
Utility: MIDDLE KUSKOKWIM ELECTRIC COOPERATIVE INC
Reporting Period: 07/01/19..06/30/20
Community Population 94
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 32
Community Facility Customers 4
Other Customers (Non-PCE)12
Fiscal Year PCE Payments $81,709
PCE Statistical Data
PCE Eligible kWh - Residential Customers 77,477 Average Annual PCE Payment per Eligible
Customer
$2,270
PCE Eligible kWh - Community Facility
Customers
29,720 Average PCE Payment per Eligible kWh $0.76
Total PCE Eligible kWh 107,197 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.29
Average Monthly PCE Eligible kWh per
Residential Customer
202 Last Reported PCE Level (per kWh)$0.77
Average Monthly PCE Eligible kWh per
Community Facility Customer
619 Effective Residential Rate (per kWh)$0.52
Average Monthly PCE Eligible Community
Facility kWh per Person
26 PCE Eligible kWh vs Total kWh Sold 47.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 256,705 Fuel Used (Gallons)24,608
Non-Diesel kWh Generated 0 Fuel Cost $79,792
Purchased kWh 0 Average Price of Fuel $3.24
Total Purchased & Generated 256,705 Fuel Cost per kWh sold $0.36
Annual Non-Fuel Expenses $220,239
Non-Fuel Expense per kWh Sold $0.98
Total Expense per kWh Sold $1.34
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 84,438 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
87.3%
Community Facility kWh Sold 29,720 Line Loss (%)7.9%
Other kWh Sold (Non-PCE)109,862 Fuel Efficiency (kWh per Gallon of Diesel)10.43
Total kWh Sold 224,020 PH Consumption as % of Generation 4.9%
Powerhouse (PH) Consumption kWh 12,525
Total kWh Sold & PH Consumption 236,545
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 52 of 187
Deering PCE
Utility: IPNATCHIAQ ELECTRIC COMPANY
Reporting Period: 07/01/19..06/30/20
Community Population 168
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 54
Community Facility Customers 5
Other Customers (Non-PCE)17
Fiscal Year PCE Payments $104,953
PCE Statistical Data
PCE Eligible kWh - Residential Customers 195,127 Average Annual PCE Payment per Eligible
Customer
$1,779
PCE Eligible kWh - Community Facility
Customers
108,384 Average PCE Payment per Eligible kWh $0.35
Total PCE Eligible kWh 303,511 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.67
Average Monthly PCE Eligible kWh per
Residential Customer
301 Last Reported PCE Level (per kWh)$0.35
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,806 Effective Residential Rate (per kWh)$0.33
Average Monthly PCE Eligible Community
Facility kWh per Person
54 PCE Eligible kWh vs Total kWh Sold 43.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 260,053 Fuel Used (Gallons)46,022
Non-Diesel kWh Generated 104,750 Fuel Cost $140,244
Purchased kWh 0 Average Price of Fuel $3.05
Total Purchased & Generated 364,803 Fuel Cost per kWh sold $0.20
Annual Non-Fuel Expenses $250,759
Non-Fuel Expense per kWh Sold $0.36
Total Expense per kWh Sold $0.56
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 265,804 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 109,585 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)324,380 Fuel Efficiency (kWh per Gallon of Diesel)5.65
Total kWh Sold 699,769 PH Consumption as % of Generation 6.5%
Powerhouse (PH) Consumption kWh 23,587
Total kWh Sold & PH Consumption 723,356
Comments
Unable To Verify Plant Meter Readings As Reported
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 53 of 187
Dillingham; Aleknagik PCE
Utility: NUSHAGAK ELECTRIC AND
Reporting Period: 07/01/19..06/30/20
Community Population 2584
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 987
Community Facility Customers 53
Other Customers (Non-PCE)466
Fiscal Year PCE Payments $863,566
PCE Statistical Data
PCE Eligible kWh - Residential Customers 3,841,331 Average Annual PCE Payment per Eligible
Customer
$830
PCE Eligible kWh - Community Facility
Customers
771,726 Average PCE Payment per Eligible kWh $0.19
Total PCE Eligible kWh 4,613,057 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.44
Average Monthly PCE Eligible kWh per
Residential Customer
324 Last Reported PCE Level (per kWh)$0.14
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,213 Effective Residential Rate (per kWh)$0.30
Average Monthly PCE Eligible Community
Facility kWh per Person
25 PCE Eligible kWh vs Total kWh Sold 26.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 19,300,221 Fuel Used (Gallons)1,292,226
Non-Diesel kWh Generated 0 Fuel Cost $3,075,180
Purchased kWh 0 Average Price of Fuel $2.38
Total Purchased & Generated 19,300,221 Fuel Cost per kWh sold $0.17
Annual Non-Fuel Expenses $5,271,240
Non-Fuel Expense per kWh Sold $0.30
Total Expense per kWh Sold $0.47
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 5,243,670 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
91.7%
Community Facility kWh Sold 796,669 Line Loss (%)5.1%
Other kWh Sold (Non-PCE)11,656,233 Fuel Efficiency (kWh per Gallon of Diesel)14.94
Total kWh Sold 17,696,572 PH Consumption as % of Generation 3.2%
Powerhouse (PH) Consumption kWh 626,145
Total kWh Sold & PH Consumption 18,322,717
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 54 of 187
Diomede PCE
Utility: DIOMEDE JOINT UTLITIES
Reporting Period: 07/01/19..06/30/20
Community Population 99
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 35
Community Facility Customers 3
Other Customers (Non-PCE)15
Fiscal Year PCE Payments $26,231
PCE Statistical Data
PCE Eligible kWh - Residential Customers 101,531 Average Annual PCE Payment per Eligible
Customer
$690
PCE Eligible kWh - Community Facility
Customers
13,049 Average PCE Payment per Eligible kWh $0.23
Total PCE Eligible kWh 114,580 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.65
Average Monthly PCE Eligible kWh per
Residential Customer
242 Last Reported PCE Level (per kWh)$0.23
Average Monthly PCE Eligible kWh per
Community Facility Customer
362 Effective Residential Rate (per kWh)$0.42
Average Monthly PCE Eligible Community
Facility kWh per Person
11 PCE Eligible kWh vs Total kWh Sold 30.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 344,319 Fuel Used (Gallons)43,046
Non-Diesel kWh Generated 0 Fuel Cost $114,230
Purchased kWh 0 Average Price of Fuel $2.65
Total Purchased & Generated 344,319 Fuel Cost per kWh sold $0.30
Annual Non-Fuel Expenses $127,965
Non-Fuel Expense per kWh Sold $0.34
Total Expense per kWh Sold $0.64
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 126,112 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 13,049 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)238,449 Fuel Efficiency (kWh per Gallon of Diesel)8.00
Total kWh Sold 377,610 PH Consumption as % of Generation 11.1%
Powerhouse (PH) Consumption kWh 38,210
Total kWh Sold & PH Consumption 415,820
Comments
kWh Generated = 9 Months; Powerhouse Consumption = 8 Months
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 55 of 187
Dot Lake; Dot Lake Village PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/19..06/30/20
Community Population 56
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 24
Community Facility Customers 6
Other Customers (Non-PCE)14
Fiscal Year PCE Payments $26,412
PCE Statistical Data
PCE Eligible kWh - Residential Customers 79,292 Average Annual PCE Payment per Eligible
Customer
$880
PCE Eligible kWh - Community Facility
Customers
40,577 Average PCE Payment per Eligible kWh $0.22
Total PCE Eligible kWh 119,869 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.37
Average Monthly PCE Eligible kWh per
Residential Customer
275 Last Reported PCE Level (per kWh)$0.18
Average Monthly PCE Eligible kWh per
Community Facility Customer
564 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per Person
60 PCE Eligible kWh vs Total kWh Sold 31.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $0
Non-Fuel Expense per kWh Sold See Comments
Total Expense per kWh Sold $0.00
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 97,232 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 41,651 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)244,378 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 383,261 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 383,261
Comments
See Tok For Power Generation
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 56 of 187
Eagle; Eagle Village PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/19..06/30/20
Community Population 135
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 141
Community Facility Customers 12
Other Customers (Non-PCE)32
Fiscal Year PCE Payments $122,061
PCE Statistical Data
PCE Eligible kWh - Residential Customers 273,046 Average Annual PCE Payment per Eligible
Customer
$798
PCE Eligible kWh - Community Facility
Customers
66,989 Average PCE Payment per Eligible kWh $0.36
Total PCE Eligible kWh 340,035 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.67
Average Monthly PCE Eligible kWh per
Residential Customer
161 Last Reported PCE Level (per kWh)$0.37
Average Monthly PCE Eligible kWh per
Community Facility Customer
465 Effective Residential Rate (per kWh)$0.31
Average Monthly PCE Eligible Community
Facility kWh per Person
41 PCE Eligible kWh vs Total kWh Sold 47.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 842,240 Fuel Used (Gallons)63,654
Non-Diesel kWh Generated 22,690 Fuel Cost $178,626
Purchased kWh 0 Average Price of Fuel $2.81
Total Purchased & Generated 864,930 Fuel Cost per kWh sold $0.25
Annual Non-Fuel Expenses $300,543
Non-Fuel Expense per kWh Sold $0.42
Total Expense per kWh Sold $0.67
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 312,446 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
82.7%
Community Facility kWh Sold 66,989 Line Loss (%)14.5%
Other kWh Sold (Non-PCE)335,442 Fuel Efficiency (kWh per Gallon of Diesel)13.23
Total kWh Sold 714,877 PH Consumption as % of Generation 2.9%
Powerhouse (PH) Consumption kWh 25,033
Total kWh Sold & PH Consumption 739,910
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 57 of 187
Eek PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 347
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 112
Community Facility Customers 7
Other Customers (Non-PCE)31
Fiscal Year PCE Payments $157,678
PCE Statistical Data
PCE Eligible kWh - Residential Customers 440,681 Average Annual PCE Payment per Eligible
Customer
$1,325
PCE Eligible kWh - Community Facility
Customers
47,466 Average PCE Payment per Eligible kWh $0.32
Total PCE Eligible kWh 488,147 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.57
Average Monthly PCE Eligible kWh per
Residential Customer
328 Last Reported PCE Level (per kWh)$0.30
Average Monthly PCE Eligible kWh per
Community Facility Customer
565 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
11 PCE Eligible kWh vs Total kWh Sold 49.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,028,580 Fuel Used (Gallons)73,049
Non-Diesel kWh Generated 0 Fuel Cost $224,204
Purchased kWh 0 Average Price of Fuel $3.07
Total Purchased & Generated 1,028,580 Fuel Cost per kWh sold $0.23
Annual Non-Fuel Expenses $206,033
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.44
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 489,017 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
95.1%
Community Facility kWh Sold 211,019 Line Loss (%)2.9%
Other kWh Sold (Non-PCE)278,242 Fuel Efficiency (kWh per Gallon of Diesel)14.08
Total kWh Sold 978,278 PH Consumption as % of Generation 1.9%
Powerhouse (PH) Consumption kWh 19,964
Total kWh Sold & PH Consumption 998,242
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 58 of 187
Egegik PCE
Utility: CITY OF EGEGIK
Reporting Period: 07/01/19..06/30/20
Community Population 77
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 88
Community Facility Customers 18
Other Customers (Non-PCE)24
Fiscal Year PCE Payments $93,563
PCE Statistical Data
PCE Eligible kWh - Residential Customers 139,161 Average Annual PCE Payment per Eligible
Customer
$883
PCE Eligible kWh - Community Facility
Customers
64,680 Average PCE Payment per Eligible kWh $0.46
Total PCE Eligible kWh 203,841 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.65
Average Monthly PCE Eligible kWh per
Residential Customer
132 Last Reported PCE Level (per kWh)$0.46
Average Monthly PCE Eligible kWh per
Community Facility Customer
299 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per Person
70 PCE Eligible kWh vs Total kWh Sold 36.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 643,662 Fuel Used (Gallons)54,254
Non-Diesel kWh Generated 0 Fuel Cost $190,573
Purchased kWh 0 Average Price of Fuel $3.51
Total Purchased & Generated 643,662 Fuel Cost per kWh sold $0.34
Annual Non-Fuel Expenses $76,325
Non-Fuel Expense per kWh Sold $0.13
Total Expense per kWh Sold $0.47
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 168,643 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
87.9%
Community Facility kWh Sold 129,000 Line Loss (%)8.0%
Other kWh Sold (Non-PCE)268,109 Fuel Efficiency (kWh per Gallon of Diesel)11.86
Total kWh Sold 565,752 PH Consumption as % of Generation 4.1%
Powerhouse (PH) Consumption kWh 26,372
Total kWh Sold & PH Consumption 592,124
Comments
Non-fuel Costs = 11 Months
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 59 of 187
Ekwok PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 106
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 52
Community Facility Customers 10
Other Customers (Non-PCE)19
Fiscal Year PCE Payments $71,925
PCE Statistical Data
PCE Eligible kWh - Residential Customers 168,726 Average Annual PCE Payment per Eligible
Customer
$1,160
PCE Eligible kWh - Community Facility
Customers
30,901 Average PCE Payment per Eligible kWh $0.36
Total PCE Eligible kWh 199,627 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.62
Average Monthly PCE Eligible kWh per
Residential Customer
270 Last Reported PCE Level (per kWh)$0.35
Average Monthly PCE Eligible kWh per
Community Facility Customer
258 Effective Residential Rate (per kWh)$0.27
Average Monthly PCE Eligible Community
Facility kWh per Person
24 PCE Eligible kWh vs Total kWh Sold 48.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $87,393
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.21
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 205,035 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 111,873 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)98,049 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 414,957 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 414,957
Comments
Receives Power From New Stuyahok Bay Via Intertie
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 60 of 187
Elfin Cove PCE
Utility: ELFIN COVE UTILITY COMMISSION
Reporting Period: 07/01/19..06/30/20
Community Population 44
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 44
Community Facility Customers 6
Other Customers (Non-PCE)26
Fiscal Year PCE Payments $29,044
PCE Statistical Data
PCE Eligible kWh - Residential Customers 52,778 Average Annual PCE Payment per Eligible
Customer
$581
PCE Eligible kWh - Community Facility
Customers
10,888 Average PCE Payment per Eligible kWh $0.46
Total PCE Eligible kWh 63,666 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.61
Average Monthly PCE Eligible kWh per
Residential Customer
100 Last Reported PCE Level (per kWh)$0.42
Average Monthly PCE Eligible kWh per
Community Facility Customer
151 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per Person
21 PCE Eligible kWh vs Total kWh Sold 26.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 305,265 Fuel Used (Gallons)25,889
Non-Diesel kWh Generated 0 Fuel Cost $111,228
Purchased kWh 0 Average Price of Fuel $4.30
Total Purchased & Generated 305,265 Fuel Cost per kWh sold $0.46
Annual Non-Fuel Expenses $47,389
Non-Fuel Expense per kWh Sold $0.20
Total Expense per kWh Sold $0.66
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 111,714 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
78.8%
Community Facility kWh Sold 10,888 Line Loss (%)13.4%
Other kWh Sold (Non-PCE)117,924 Fuel Efficiency (kWh per Gallon of Diesel)11.79
Total kWh Sold 240,526 PH Consumption as % of Generation 7.8%
Powerhouse (PH) Consumption kWh 23,693
Total kWh Sold & PH Consumption 264,219
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 61 of 187
Elim PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 368
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 91
Community Facility Customers 10
Other Customers (Non-PCE)33
Fiscal Year PCE Payments $179,178
PCE Statistical Data
PCE Eligible kWh - Residential Customers 415,229 Average Annual PCE Payment per Eligible
Customer
$1,774
PCE Eligible kWh - Community Facility
Customers
142,160 Average PCE Payment per Eligible kWh $0.32
Total PCE Eligible kWh 557,389 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.55
Average Monthly PCE Eligible kWh per
Residential Customer
380 Last Reported PCE Level (per kWh)$0.29
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,185 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
32 PCE Eligible kWh vs Total kWh Sold 45.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,310,465 Fuel Used (Gallons)87,506
Non-Diesel kWh Generated 0 Fuel Cost $281,008
Purchased kWh 0 Average Price of Fuel $3.21
Total Purchased & Generated 1,310,465 Fuel Cost per kWh sold $0.23
Annual Non-Fuel Expenses $257,226
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.44
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 533,492 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
93.2%
Community Facility kWh Sold 258,018 Line Loss (%)5.0%
Other kWh Sold (Non-PCE)429,841 Fuel Efficiency (kWh per Gallon of Diesel)14.98
Total kWh Sold 1,221,351 PH Consumption as % of Generation 1.8%
Powerhouse (PH) Consumption kWh 23,133
Total kWh Sold & PH Consumption 1,244,484
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 62 of 187
Emmonak PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 867
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 209
Community Facility Customers 21
Other Customers (Non-PCE)58
Fiscal Year PCE Payments $403,118
PCE Statistical Data
PCE Eligible kWh - Residential Customers 889,608 Average Annual PCE Payment per Eligible
Customer
$1,753
PCE Eligible kWh - Community Facility
Customers
628,978 Average PCE Payment per Eligible kWh $0.27
Total PCE Eligible kWh 1,518,586 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.54
Average Monthly PCE Eligible kWh per
Residential Customer
355 Last Reported PCE Level (per kWh)$0.27
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,496 Effective Residential Rate (per kWh)$0.27
Average Monthly PCE Eligible Community
Facility kWh per Person
60 PCE Eligible kWh vs Total kWh Sold 40.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 5,402,548 Fuel Used (Gallons)374,892
Non-Diesel kWh Generated 540,831 Fuel Cost $1,160,363
Purchased kWh 0 Average Price of Fuel $3.10
Total Purchased & Generated 5,943,379 Fuel Cost per kWh sold $0.31
Annual Non-Fuel Expenses $781,692
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.52
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,111,697 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
62.4%
Community Facility kWh Sold 853,529 Line Loss (%)35.6%
Other kWh Sold (Non-PCE)1,746,371 Fuel Efficiency (kWh per Gallon of Diesel)14.41
Total kWh Sold 3,711,597 PH Consumption as % of Generation 1.9%
Powerhouse (PH) Consumption kWh 114,406
Total kWh Sold & PH Consumption 3,826,003
Comments
Provides Power To Alakanuk Via Intertie
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 63 of 187
False Pass PCE
Utility: CITY OF FALSE PASS
Reporting Period: 07/01/19..06/30/20
Community Population 39
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 30
Community Facility Customers 9
Other Customers (Non-PCE)18
Fiscal Year PCE Payments $28,840
PCE Statistical Data
PCE Eligible kWh - Residential Customers 66,820 Average Annual PCE Payment per Eligible
Customer
$739
PCE Eligible kWh - Community Facility
Customers
32,760 Average PCE Payment per Eligible kWh $0.29
Total PCE Eligible kWh 99,580 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.62
Average Monthly PCE Eligible kWh per
Residential Customer
186 Last Reported PCE Level (per kWh)$0.29
Average Monthly PCE Eligible kWh per
Community Facility Customer
303 Effective Residential Rate (per kWh)$0.33
Average Monthly PCE Eligible Community
Facility kWh per Person
70 PCE Eligible kWh vs Total kWh Sold 14.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 814,598 Fuel Used (Gallons)68,340
Non-Diesel kWh Generated 0 Fuel Cost $165,817
Purchased kWh 0 Average Price of Fuel $2.43
Total Purchased & Generated 814,598 Fuel Cost per kWh sold $0.24
Annual Non-Fuel Expenses $98,947
Non-Fuel Expense per kWh Sold $0.15
Total Expense per kWh Sold $0.39
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 101,522 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
83.1%
Community Facility kWh Sold 68,324 Line Loss (%)11.8%
Other kWh Sold (Non-PCE)507,247 Fuel Efficiency (kWh per Gallon of Diesel)11.92
Total kWh Sold 677,093 PH Consumption as % of Generation 5.1%
Powerhouse (PH) Consumption kWh 41,525
Total kWh Sold & PH Consumption 718,618
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 64 of 187
Fort Yukon PCE
Utility: GWITCHYAA ZHEE UTILITY COMPANY
Reporting Period: 07/01/19..06/30/20
Community Population 540
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 270
Community Facility Customers 17
Other Customers (Non-PCE)77
Fiscal Year PCE Payments $396,043
PCE Statistical Data
PCE Eligible kWh - Residential Customers 802,800 Average Annual PCE Payment per Eligible
Customer
$1,380
PCE Eligible kWh - Community Facility
Customers
345,897 Average PCE Payment per Eligible kWh $0.34
Total PCE Eligible kWh 1,148,697 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.65
Average Monthly PCE Eligible kWh per
Residential Customer
248 Last Reported PCE Level (per kWh)$0.36
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,696 Effective Residential Rate (per kWh)$0.29
Average Monthly PCE Eligible Community
Facility kWh per Person
53 PCE Eligible kWh vs Total kWh Sold 47.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 3,179,348 Fuel Used (Gallons)227,061
Non-Diesel kWh Generated 0 Fuel Cost $1,331,486
Purchased kWh 0 Average Price of Fuel $5.86
Total Purchased & Generated 3,179,348 Fuel Cost per kWh sold $0.55
Annual Non-Fuel Expenses $515,936
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.76
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 933,702 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
76.1%
Community Facility kWh Sold 348,380 Line Loss (%)21.0%
Other kWh Sold (Non-PCE)1,138,772 Fuel Efficiency (kWh per Gallon of Diesel)14.00
Total kWh Sold 2,420,854 PH Consumption as % of Generation 2.9%
Powerhouse (PH) Consumption kWh 90,918
Total kWh Sold & PH Consumption 2,511,772
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 65 of 187
Galena PCE
Utility: CITY OF GALENA
Reporting Period: 07/01/19..06/30/20
Community Population 460
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 209
Community Facility Customers 14
Other Customers (Non-PCE)167
Fiscal Year PCE Payments $232,008
PCE Statistical Data
PCE Eligible kWh - Residential Customers 673,697 Average Annual PCE Payment per Eligible
Customer
$1,040
PCE Eligible kWh - Community Facility
Customers
378,378 Average PCE Payment per Eligible kWh $0.22
Total PCE Eligible kWh 1,052,075 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.60
Average Monthly PCE Eligible kWh per
Residential Customer
269 Last Reported PCE Level (per kWh)$0.23
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,252 Effective Residential Rate (per kWh)$0.37
Average Monthly PCE Eligible Community
Facility kWh per Person
69 PCE Eligible kWh vs Total kWh Sold 22.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 5,607,852 Fuel Used (Gallons)409,078
Non-Diesel kWh Generated 0 Fuel Cost $1,133,277
Purchased kWh 0 Average Price of Fuel $2.77
Total Purchased & Generated 5,607,852 Fuel Cost per kWh sold $0.24
Annual Non-Fuel Expenses $784,665
Non-Fuel Expense per kWh Sold $0.17
Total Expense per kWh Sold $0.40
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 900,453 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
84.8%
Community Facility kWh Sold 564,354 Line Loss (%)11.1%
Other kWh Sold (Non-PCE)3,289,237 Fuel Efficiency (kWh per Gallon of Diesel)13.71
Total kWh Sold 4,754,044 PH Consumption as % of Generation 4.1%
Powerhouse (PH) Consumption kWh 231,380
Total kWh Sold & PH Consumption 4,985,424
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 66 of 187
Gambell PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 722
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 165
Community Facility Customers 15
Other Customers (Non-PCE)34
Fiscal Year PCE Payments $249,779
PCE Statistical Data
PCE Eligible kWh - Residential Customers 628,550 Average Annual PCE Payment per Eligible
Customer
$1,388
PCE Eligible kWh - Community Facility
Customers
222,460 Average PCE Payment per Eligible kWh $0.29
Total PCE Eligible kWh 851,010 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.59
Average Monthly PCE Eligible kWh per
Residential Customer
317 Last Reported PCE Level (per kWh)$0.30
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,236 Effective Residential Rate (per kWh)$0.29
Average Monthly PCE Eligible Community
Facility kWh per Person
26 PCE Eligible kWh vs Total kWh Sold 48.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,635,119 Fuel Used (Gallons)124,108
Non-Diesel kWh Generated 285,498 Fuel Cost $387,726
Purchased kWh 0 Average Price of Fuel $3.12
Total Purchased & Generated 1,920,617 Fuel Cost per kWh sold $0.22
Annual Non-Fuel Expenses $369,142
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.43
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 738,811 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
91.3%
Community Facility kWh Sold 425,392 Line Loss (%)4.4%
Other kWh Sold (Non-PCE)588,541 Fuel Efficiency (kWh per Gallon of Diesel)13.17
Total kWh Sold 1,752,744 PH Consumption as % of Generation 4.4%
Powerhouse (PH) Consumption kWh 83,639
Total kWh Sold & PH Consumption 1,836,383
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 67 of 187
Golovin PCE
Utility: GOLOVIN POWER UTILITIES
Reporting Period: 07/01/19..06/30/20
Community Population 163
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 48
Community Facility Customers 8
Other Customers (Non-PCE)45
Fiscal Year PCE Payments $52,731
PCE Statistical Data
PCE Eligible kWh - Residential Customers 219,681 Average Annual PCE Payment per Eligible
Customer
$942
PCE Eligible kWh - Community Facility
Customers
125,283 Average PCE Payment per Eligible kWh $0.15
Total PCE Eligible kWh 344,964 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.44
Average Monthly PCE Eligible kWh per
Residential Customer
381 Last Reported PCE Level (per kWh)$0.15
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,305 Effective Residential Rate (per kWh)$0.29
Average Monthly PCE Eligible Community
Facility kWh per Person
64 PCE Eligible kWh vs Total kWh Sold 38.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 939,087 Fuel Used (Gallons)79,964
Non-Diesel kWh Generated 0 Fuel Cost $222,436
Purchased kWh 0 Average Price of Fuel $2.78
Total Purchased & Generated 939,087 Fuel Cost per kWh sold $0.25
Annual Non-Fuel Expenses $148,902
Non-Fuel Expense per kWh Sold $0.17
Total Expense per kWh Sold $0.41
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 270,659 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
95.5%
Community Facility kWh Sold 155,558 Line Loss (%)0.9%
Other kWh Sold (Non-PCE)470,216 Fuel Efficiency (kWh per Gallon of Diesel)11.74
Total kWh Sold 896,433 PH Consumption as % of Generation 3.7%
Powerhouse (PH) Consumption kWh 34,646
Total kWh Sold & PH Consumption 931,079
Comments
kWh's Generated & Powerhouse Consumption = 10 Months
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 68 of 187
Goodnews Bay PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 283
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 75
Community Facility Customers 10
Other Customers (Non-PCE)12
Fiscal Year PCE Payments $125,429
PCE Statistical Data
PCE Eligible kWh - Residential Customers 338,796 Average Annual PCE Payment per Eligible
Customer
$1,476
PCE Eligible kWh - Community Facility
Customers
74,630 Average PCE Payment per Eligible kWh $0.30
Total PCE Eligible kWh 413,426 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.56
Average Monthly PCE Eligible kWh per
Residential Customer
376 Last Reported PCE Level (per kWh)$0.29
Average Monthly PCE Eligible kWh per
Community Facility Customer
622 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
22 PCE Eligible kWh vs Total kWh Sold 57.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 759,570 Fuel Used (Gallons)57,785
Non-Diesel kWh Generated 0 Fuel Cost $182,760
Purchased kWh 0 Average Price of Fuel $3.16
Total Purchased & Generated 759,570 Fuel Cost per kWh sold $0.25
Annual Non-Fuel Expenses $152,462
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.46
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 426,796 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
95.3%
Community Facility kWh Sold 120,533 Line Loss (%)2.7%
Other kWh Sold (Non-PCE)176,583 Fuel Efficiency (kWh per Gallon of Diesel)13.14
Total kWh Sold 723,912 PH Consumption as % of Generation 2.0%
Powerhouse (PH) Consumption kWh 15,188
Total kWh Sold & PH Consumption 739,100
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 69 of 187
Grayling PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 205
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 67
Community Facility Customers 10
Other Customers (Non-PCE)18
Fiscal Year PCE Payments $110,518
PCE Statistical Data
PCE Eligible kWh - Residential Customers 224,287 Average Annual PCE Payment per Eligible
Customer
$1,435
PCE Eligible kWh - Community Facility
Customers
151,340 Average PCE Payment per Eligible kWh $0.29
Total PCE Eligible kWh 375,627 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.55
Average Monthly PCE Eligible kWh per
Residential Customer
279 Last Reported PCE Level (per kWh)$0.29
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,261 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
62 PCE Eligible kWh vs Total kWh Sold 61.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 663,830 Fuel Used (Gallons)49,887
Non-Diesel kWh Generated 0 Fuel Cost $148,159
Purchased kWh 0 Average Price of Fuel $2.97
Total Purchased & Generated 663,830 Fuel Cost per kWh sold $0.24
Annual Non-Fuel Expenses $128,459
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.45
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 252,285 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
91.9%
Community Facility kWh Sold 229,078 Line Loss (%)4.3%
Other kWh Sold (Non-PCE)128,580 Fuel Efficiency (kWh per Gallon of Diesel)13.31
Total kWh Sold 609,943 PH Consumption as % of Generation 3.8%
Powerhouse (PH) Consumption kWh 25,233
Total kWh Sold & PH Consumption 635,176
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 70 of 187
Gustavus PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/19..06/30/20
Community Population 554
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 479
Community Facility Customers 5
Other Customers (Non-PCE)111
Fiscal Year PCE Payments $115,592
PCE Statistical Data
PCE Eligible kWh - Residential Customers 990,189 Average Annual PCE Payment per Eligible
Customer
$239
PCE Eligible kWh - Community Facility
Customers
33,571 Average PCE Payment per Eligible kWh $0.11
Total PCE Eligible kWh 1,023,760 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.44
Average Monthly PCE Eligible kWh per
Residential Customer
172 Last Reported PCE Level (per kWh)$0.11
Average Monthly PCE Eligible kWh per
Community Facility Customer
560 Effective Residential Rate (per kWh)$0.33
Average Monthly PCE Eligible Community
Facility kWh per Person
5 PCE Eligible kWh vs Total kWh Sold 53.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 244,287 Fuel Used (Gallons)18,110
Non-Diesel kWh Generated 2,148,695 Fuel Cost $69,433
Purchased kWh 0 Average Price of Fuel $3.83
Total Purchased & Generated 2,392,982 Fuel Cost per kWh sold $0.04
Annual Non-Fuel Expenses $584,455
Non-Fuel Expense per kWh Sold $0.31
Total Expense per kWh Sold $0.34
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,234,570 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
79.8%
Community Facility kWh Sold 33,571 Line Loss (%)17.5%
Other kWh Sold (Non-PCE)642,419 Fuel Efficiency (kWh per Gallon of Diesel)13.49
Total kWh Sold 1,910,560 PH Consumption as % of Generation 2.7%
Powerhouse (PH) Consumption kWh 64,475
Total kWh Sold & PH Consumption 1,975,035
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 71 of 187
Haines; Covenant Life PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/19..06/30/20
Community Population 2533
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 1,161
Community Facility Customers 39
Other Customers (Non-PCE)380
Fiscal Year PCE Payments $64,771
PCE Statistical Data
PCE Eligible kWh - Residential Customers 3,729,408 Average Annual PCE Payment per Eligible
Customer
$54
PCE Eligible kWh - Community Facility
Customers
1,049,038 Average PCE Payment per Eligible kWh $0.01
Total PCE Eligible kWh 4,778,446 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.26
Average Monthly PCE Eligible kWh per
Residential Customer
268 Last Reported PCE Level (per kWh)$0.01
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,242 Effective Residential Rate (per kWh)$0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
35 PCE Eligible kWh vs Total kWh Sold 35.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 265,911 Fuel Used (Gallons)19,825
Non-Diesel kWh Generated 0 Fuel Cost $58,178
Purchased kWh 14,802,264 Average Price of Fuel $2.93
Total Purchased & Generated 15,068,175 Fuel Cost per kWh sold $0.00
Annual Non-Fuel Expenses $1,473,858
Non-Fuel Expense per kWh Sold $0.11
Total Expense per kWh Sold $0.11
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 5,646,126 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
88.8%
Community Facility kWh Sold 1,049,038 Line Loss (%)9.0%
Other kWh Sold (Non-PCE)6,687,406 Fuel Efficiency (kWh per Gallon of Diesel)13.41
Total kWh Sold 13,382,570 PH Consumption as % of Generation 2.1%
Powerhouse (PH) Consumption kWh 322,760
Total kWh Sold & PH Consumption 13,705,330
Comments
Sells Power To Inside Passage Electric Cooperative (Chilkat Valley) For Resale
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 72 of 187
Healy Lake PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/19..06/30/20
Community Population 23
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 7
Community Facility Customers 3
Other Customers (Non-PCE)2
Fiscal Year PCE Payments $19,375
PCE Statistical Data
PCE Eligible kWh - Residential Customers 17,487 Average Annual PCE Payment per Eligible
Customer
$1,938
PCE Eligible kWh - Community Facility
Customers
19,320 Average PCE Payment per Eligible kWh $0.53
Total PCE Eligible kWh 36,807 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.92
Average Monthly PCE Eligible kWh per
Residential Customer
208 Last Reported PCE Level (per kWh)$0.60
Average Monthly PCE Eligible kWh per
Community Facility Customer
537 Effective Residential Rate (per kWh)$0.32
Average Monthly PCE Eligible Community
Facility kWh per Person
70 PCE Eligible kWh vs Total kWh Sold 53.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 79,825 Fuel Used (Gallons)8,910
Non-Diesel kWh Generated 0 Fuel Cost $32,547
Purchased kWh 0 Average Price of Fuel $3.65
Total Purchased & Generated 79,825 Fuel Cost per kWh sold $0.48
Annual Non-Fuel Expenses $29,768
Non-Fuel Expense per kWh Sold $0.43
Total Expense per kWh Sold $0.91
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 19,055 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
85.8%
Community Facility kWh Sold 35,674 Line Loss (%)7.7%
Other kWh Sold (Non-PCE)13,764 Fuel Efficiency (kWh per Gallon of Diesel)8.96
Total kWh Sold 68,493 PH Consumption as % of Generation 6.5%
Powerhouse (PH) Consumption kWh 5,225
Total kWh Sold & PH Consumption 73,718
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 73 of 187
Hollis PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/19..06/30/20
Community Population 124
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 132
Community Facility Customers 1
Other Customers (Non-PCE)31
Fiscal Year PCE Payments $6,303
PCE Statistical Data
PCE Eligible kWh - Residential Customers 417,013 Average Annual PCE Payment per Eligible
Customer
$47
PCE Eligible kWh - Community Facility
Customers
3,033 Average PCE Payment per Eligible kWh $0.02
Total PCE Eligible kWh 420,046 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.27
Average Monthly PCE Eligible kWh per
Residential Customer
263 Last Reported PCE Level (per kWh)$0.02
Average Monthly PCE Eligible kWh per
Community Facility Customer
253 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
2 PCE Eligible kWh vs Total kWh Sold 19.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $0
Non-Fuel Expense per kWh Sold See Comments
Total Expense per kWh Sold $0.00
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 659,646 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 3,033 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)1,507,807 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 2,170,486 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 15,441
Total kWh Sold & PH Consumption 2,185,927
Comments
See Craig For Power Generation
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 74 of 187
Holy Cross PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 168
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 76
Community Facility Customers 11
Other Customers (Non-PCE)15
Fiscal Year PCE Payments $101,302
PCE Statistical Data
PCE Eligible kWh - Residential Customers 236,779 Average Annual PCE Payment per Eligible
Customer
$1,164
PCE Eligible kWh - Community Facility
Customers
98,254 Average PCE Payment per Eligible kWh $0.30
Total PCE Eligible kWh 335,033 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.56
Average Monthly PCE Eligible kWh per
Residential Customer
260 Last Reported PCE Level (per kWh)$0.30
Average Monthly PCE Eligible kWh per
Community Facility Customer
744 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
49 PCE Eligible kWh vs Total kWh Sold 60.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 581,543 Fuel Used (Gallons)49,531
Non-Diesel kWh Generated 0 Fuel Cost $146,538
Purchased kWh 0 Average Price of Fuel $2.96
Total Purchased & Generated 581,543 Fuel Cost per kWh sold $0.26
Annual Non-Fuel Expenses $117,629
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.47
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 273,407 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
96.0%
Community Facility kWh Sold 204,945 Line Loss (%)0.2%
Other kWh Sold (Non-PCE)80,168 Fuel Efficiency (kWh per Gallon of Diesel)11.74
Total kWh Sold 558,520 PH Consumption as % of Generation 3.7%
Powerhouse (PH) Consumption kWh 21,575
Total kWh Sold & PH Consumption 580,095
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 75 of 187
Hoonah PCE
Utility: INSIDE PASSAGE ELECTRIC
Reporting Period: 07/01/19..06/30/20
Community Population 789
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 392
Community Facility Customers 27
Other Customers (Non-PCE)73
Fiscal Year PCE Payments $717,931
PCE Statistical Data
PCE Eligible kWh - Residential Customers 1,439,416 Average Annual PCE Payment per Eligible
Customer
$1,713
PCE Eligible kWh - Community Facility
Customers
615,497 Average PCE Payment per Eligible kWh $0.35
Total PCE Eligible kWh 2,054,913 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.60
Average Monthly PCE Eligible kWh per
Residential Customer
306 Last Reported PCE Level (per kWh)$0.33
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,900 Effective Residential Rate (per kWh)$0.27
Average Monthly PCE Eligible Community
Facility kWh per Person
65 PCE Eligible kWh vs Total kWh Sold 48.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 3,436,087 Fuel Used (Gallons)234,537
Non-Diesel kWh Generated 1,264,506 Fuel Cost $637,745
Purchased kWh 0 Average Price of Fuel $2.72
Total Purchased & Generated 4,700,593 Fuel Cost per kWh sold $0.15
Annual Non-Fuel Expenses $1,118,931
Non-Fuel Expense per kWh Sold $0.26
Total Expense per kWh Sold $0.41
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,792,003 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
91.1%
Community Facility kWh Sold 671,117 Line Loss (%)6.9%
Other kWh Sold (Non-PCE)1,820,208 Fuel Efficiency (kWh per Gallon of Diesel)14.65
Total kWh Sold 4,283,328 PH Consumption as % of Generation 2.0%
Powerhouse (PH) Consumption kWh 92,353
Total kWh Sold & PH Consumption 4,375,681
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 76 of 187
Hooper Bay PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 1247
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 268
Community Facility Customers 11
Other Customers (Non-PCE)61
Fiscal Year PCE Payments $412,306
PCE Statistical Data
PCE Eligible kWh - Residential Customers 1,098,527 Average Annual PCE Payment per Eligible
Customer
$1,478
PCE Eligible kWh - Community Facility
Customers
327,449 Average PCE Payment per Eligible kWh $0.29
Total PCE Eligible kWh 1,425,976 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.56
Average Monthly PCE Eligible kWh per
Residential Customer
342 Last Reported PCE Level (per kWh)$0.28
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,481 Effective Residential Rate (per kWh)$0.28
Average Monthly PCE Eligible Community
Facility kWh per Person
22 PCE Eligible kWh vs Total kWh Sold 42.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 3,240,439 Fuel Used (Gallons)229,241
Non-Diesel kWh Generated 336,061 Fuel Cost $689,643
Purchased kWh 0 Average Price of Fuel $3.01
Total Purchased & Generated 3,576,500 Fuel Cost per kWh sold $0.20
Annual Non-Fuel Expenses $714,360
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.41
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,364,514 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
94.8%
Community Facility kWh Sold 830,943 Line Loss (%)3.1%
Other kWh Sold (Non-PCE)1,196,438 Fuel Efficiency (kWh per Gallon of Diesel)14.14
Total kWh Sold 3,391,895 PH Consumption as % of Generation 2.1%
Powerhouse (PH) Consumption kWh 74,908
Total kWh Sold & PH Consumption 3,466,803
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 77 of 187
Hughes PCE
Utility: HUGHES POWER & LIGHT
Reporting Period: 07/01/19..06/30/20
Community Population 104
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 47
Community Facility Customers 3
Other Customers (Non-PCE)16
Fiscal Year PCE Payments $112,978
PCE Statistical Data
PCE Eligible kWh - Residential Customers 145,182 Average Annual PCE Payment per Eligible
Customer
$2,260
PCE Eligible kWh - Community Facility
Customers
74,081 Average PCE Payment per Eligible kWh $0.52
Total PCE Eligible kWh 219,263 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.71
Average Monthly PCE Eligible kWh per
Residential Customer
257 Last Reported PCE Level (per kWh)$0.48
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,058 Effective Residential Rate (per kWh)$0.23
Average Monthly PCE Eligible Community
Facility kWh per Person
59 PCE Eligible kWh vs Total kWh Sold 53.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 438,546 Fuel Used (Gallons)40,576
Non-Diesel kWh Generated 0 Fuel Cost $203,523
Purchased kWh 0 Average Price of Fuel $5.02
Total Purchased & Generated 438,546 Fuel Cost per kWh sold $0.49
Annual Non-Fuel Expenses $72,362
Non-Fuel Expense per kWh Sold $0.18
Total Expense per kWh Sold $0.67
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 182,435 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
94.0%
Community Facility kWh Sold 77,784 Line Loss (%)0.1%
Other kWh Sold (Non-PCE)152,009 Fuel Efficiency (kWh per Gallon of Diesel)10.81
Total kWh Sold 412,228 PH Consumption as % of Generation 5.9%
Powerhouse (PH) Consumption kWh 25,744
Total kWh Sold & PH Consumption 437,972
Comments
kWh's Generated, Powerhouse Consumption & Non-fuel Costs = 10 Months
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 78 of 187
Huslia PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 310
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 102
Community Facility Customers 19
Other Customers (Non-PCE)25
Fiscal Year PCE Payments $169,654
PCE Statistical Data
PCE Eligible kWh - Residential Customers 390,415 Average Annual PCE Payment per Eligible
Customer
$1,402
PCE Eligible kWh - Community Facility
Customers
157,770 Average PCE Payment per Eligible kWh $0.31
Total PCE Eligible kWh 548,185 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.57
Average Monthly PCE Eligible kWh per
Residential Customer
319 Last Reported PCE Level (per kWh)$0.30
Average Monthly PCE Eligible kWh per
Community Facility Customer
692 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
42 PCE Eligible kWh vs Total kWh Sold 56.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,041,751 Fuel Used (Gallons)74,259
Non-Diesel kWh Generated 0 Fuel Cost $235,301
Purchased kWh 0 Average Price of Fuel $3.17
Total Purchased & Generated 1,041,751 Fuel Cost per kWh sold $0.24
Annual Non-Fuel Expenses $204,954
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.45
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 493,998 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
93.4%
Community Facility kWh Sold 207,422 Line Loss (%)3.5%
Other kWh Sold (Non-PCE)271,736 Fuel Efficiency (kWh per Gallon of Diesel)14.03
Total kWh Sold 973,156 PH Consumption as % of Generation 3.1%
Powerhouse (PH) Consumption kWh 32,035
Total kWh Sold & PH Consumption 1,005,191
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 79 of 187
Hydaburg PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/19..06/30/20
Community Population 398
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 119
Community Facility Customers 8
Other Customers (Non-PCE)57
Fiscal Year PCE Payments $9,722
PCE Statistical Data
PCE Eligible kWh - Residential Customers 514,494 Average Annual PCE Payment per Eligible
Customer
$77
PCE Eligible kWh - Community Facility
Customers
129,113 Average PCE Payment per Eligible kWh $0.02
Total PCE Eligible kWh 643,607 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.27
Average Monthly PCE Eligible kWh per
Residential Customer
360 Last Reported PCE Level (per kWh)$0.02
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,345 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
27 PCE Eligible kWh vs Total kWh Sold 39.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $0
Non-Fuel Expense per kWh Sold See Comments
Total Expense per kWh Sold $0.00
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 701,193 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 131,422 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)804,253 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 1,636,868 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 32,631
Total kWh Sold & PH Consumption 1,669,499
Comments
See Craig For Power Generation
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 80 of 187
Igiugig PCE
Utility: IGIUGIG ELECTRIC COMPANY
Reporting Period: 07/01/19..06/30/20
Community Population 52
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 30
Community Facility Customers 12
Other Customers (Non-PCE)12
Fiscal Year PCE Payments $76,227
PCE Statistical Data
PCE Eligible kWh - Residential Customers 82,735 Average Annual PCE Payment per Eligible
Customer
$1,815
PCE Eligible kWh - Community Facility
Customers
43,680 Average PCE Payment per Eligible kWh $0.60
Total PCE Eligible kWh 126,415 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.92
Average Monthly PCE Eligible kWh per
Residential Customer
230 Last Reported PCE Level (per kWh)$0.57
Average Monthly PCE Eligible kWh per
Community Facility Customer
303 Effective Residential Rate (per kWh)$0.35
Average Monthly PCE Eligible Community
Facility kWh per Person
70 PCE Eligible kWh vs Total kWh Sold 49.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 310,014 Fuel Used (Gallons)23,384
Non-Diesel kWh Generated 8,773 Fuel Cost $138,395
Purchased kWh 0 Average Price of Fuel $5.92
Total Purchased & Generated 318,787 Fuel Cost per kWh sold $0.54
Annual Non-Fuel Expenses $73,239
Non-Fuel Expense per kWh Sold $0.28
Total Expense per kWh Sold $0.82
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 97,168 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
80.8%
Community Facility kWh Sold 76,095 Line Loss (%)13.8%
Other kWh Sold (Non-PCE)84,336 Fuel Efficiency (kWh per Gallon of Diesel)13.26
Total kWh Sold 257,599 PH Consumption as % of Generation 5.4%
Powerhouse (PH) Consumption kWh 17,299
Total kWh Sold & PH Consumption 274,898
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 81 of 187
Iliamna Newhalen Nondalton PCE
Utility: ILIAMNA NEWHALEN NONDALTON
Reporting Period: 07/01/19..06/30/20
Community Population 445
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 180
Community Facility Customers 15
Other Customers (Non-PCE)98
Fiscal Year PCE Payments $356,072
PCE Statistical Data
PCE Eligible kWh - Residential Customers 599,334 Average Annual PCE Payment per Eligible
Customer
$1,826
PCE Eligible kWh - Community Facility
Customers
341,307 Average PCE Payment per Eligible kWh $0.38
Total PCE Eligible kWh 940,641 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.65
Average Monthly PCE Eligible kWh per
Residential Customer
277 Last Reported PCE Level (per kWh)$0.38
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,896 Effective Residential Rate (per kWh)$0.27
Average Monthly PCE Eligible Community
Facility kWh per Person
64 PCE Eligible kWh vs Total kWh Sold 29.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 50,700 Fuel Used (Gallons)3,816
Non-Diesel kWh Generated 3,911,120 Fuel Cost $17,621
Purchased kWh 0 Average Price of Fuel $4.62
Total Purchased & Generated 3,961,820 Fuel Cost per kWh sold $0.01
Annual Non-Fuel Expenses $1,401,591
Non-Fuel Expense per kWh Sold $0.44
Total Expense per kWh Sold $0.45
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 752,289 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
79.7%
Community Facility kWh Sold 344,834 Line Loss (%)8.5%
Other kWh Sold (Non-PCE)2,061,281 Fuel Efficiency (kWh per Gallon of Diesel)13.29
Total kWh Sold 3,158,404 PH Consumption as % of Generation 11.7%
Powerhouse (PH) Consumption kWh 465,299
Total kWh Sold & PH Consumption 3,623,703
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 82 of 187
Kake PCE
Utility: INSIDE PASSAGE ELECTRIC
Reporting Period: 07/01/19..06/30/20
Community Population 601
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 237
Community Facility Customers 15
Other Customers (Non-PCE)55
Fiscal Year PCE Payments $330,644
PCE Statistical Data
PCE Eligible kWh - Residential Customers 766,406 Average Annual PCE Payment per Eligible
Customer
$1,312
PCE Eligible kWh - Community Facility
Customers
180,127 Average PCE Payment per Eligible kWh $0.35
Total PCE Eligible kWh 946,533 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.60
Average Monthly PCE Eligible kWh per
Residential Customer
269 Last Reported PCE Level (per kWh)$0.33
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,001 Effective Residential Rate (per kWh)$0.27
Average Monthly PCE Eligible Community
Facility kWh per Person
25 PCE Eligible kWh vs Total kWh Sold 48.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,276,881 Fuel Used (Gallons)148,456
Non-Diesel kWh Generated 0 Fuel Cost $402,756
Purchased kWh 0 Average Price of Fuel $2.71
Total Purchased & Generated 2,276,881 Fuel Cost per kWh sold $0.20
Annual Non-Fuel Expenses $707,724
Non-Fuel Expense per kWh Sold $0.36
Total Expense per kWh Sold $0.56
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 912,864 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
86.4%
Community Facility kWh Sold 180,127 Line Loss (%)10.4%
Other kWh Sold (Non-PCE)874,786 Fuel Efficiency (kWh per Gallon of Diesel)15.34
Total kWh Sold 1,967,777 PH Consumption as % of Generation 3.2%
Powerhouse (PH) Consumption kWh 72,135
Total kWh Sold & PH Consumption 2,039,912
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 83 of 187
Kaktovik PCE
Utility: NORTH SLOPE BOROUGH
Reporting Period: 07/01/19..06/30/20
Community Population 246
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 77
Community Facility Customers 3
Other Customers (Non-PCE)56
Fiscal Year PCE Payments $4,314
PCE Statistical Data
PCE Eligible kWh - Residential Customers 185,984 Average Annual PCE Payment per Eligible
Customer
$54
PCE Eligible kWh - Community Facility
Customers
58,250 Average PCE Payment per Eligible kWh $0.02
Total PCE Eligible kWh 244,234 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.21
Average Monthly PCE Eligible kWh per
Residential Customer
201 Last Reported PCE Level (per kWh)$0.00
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,618 Effective Residential Rate (per kWh)$0.21
Average Monthly PCE Eligible Community
Facility kWh per Person
20 PCE Eligible kWh vs Total kWh Sold 5.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 4,346,774 Fuel Used (Gallons)338,950
Non-Diesel kWh Generated 0 Fuel Cost $1,159,388
Purchased kWh 0 Average Price of Fuel $3.42
Total Purchased & Generated 4,346,774 Fuel Cost per kWh sold $0.28
Annual Non-Fuel Expenses $1,162,028
Non-Fuel Expense per kWh Sold $0.28
Total Expense per kWh Sold $0.55
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 754,525 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
96.5%
Community Facility kWh Sold 58,250 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)3,383,479 Fuel Efficiency (kWh per Gallon of Diesel)12.82
Total kWh Sold 4,196,254 PH Consumption as % of Generation 4.1%
Powerhouse (PH) Consumption kWh 178,610
Total kWh Sold & PH Consumption 4,374,864
Comments
kWh's Gen'd & Pwrhse Consumption = 11 Months. Residential PCE Level = Zero
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 84 of 187
Kaltag PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 169
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 68
Community Facility Customers 12
Other Customers (Non-PCE)21
Fiscal Year PCE Payments $98,027
PCE Statistical Data
PCE Eligible kWh - Residential Customers 219,505 Average Annual PCE Payment per Eligible
Customer
$1,225
PCE Eligible kWh - Community Facility
Customers
90,751 Average PCE Payment per Eligible kWh $0.32
Total PCE Eligible kWh 310,256 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.58
Average Monthly PCE Eligible kWh per
Residential Customer
269 Last Reported PCE Level (per kWh)$0.32
Average Monthly PCE Eligible kWh per
Community Facility Customer
630 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
45 PCE Eligible kWh vs Total kWh Sold 53.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 641,597 Fuel Used (Gallons)46,014
Non-Diesel kWh Generated 3,984 Fuel Cost $133,473
Purchased kWh 0 Average Price of Fuel $2.90
Total Purchased & Generated 645,581 Fuel Cost per kWh sold $0.23
Annual Non-Fuel Expenses $122,375
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.44
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 244,869 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
90.0%
Community Facility kWh Sold 142,908 Line Loss (%)6.7%
Other kWh Sold (Non-PCE)193,279 Fuel Efficiency (kWh per Gallon of Diesel)13.94
Total kWh Sold 581,056 PH Consumption as % of Generation 3.3%
Powerhouse (PH) Consumption kWh 21,043
Total kWh Sold & PH Consumption 602,099
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 85 of 187
Karluk PCE
Utility: KARLUK IRA TRIBAL COUNCIL
Reporting Period: 07/01/19..06/30/20
Community Population 29
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 13
Community Facility Customers 4
Other Customers (Non-PCE)13
Fiscal Year PCE Payments $27,144
PCE Statistical Data
PCE Eligible kWh - Residential Customers 47,578 Average Annual PCE Payment per Eligible
Customer
$1,597
PCE Eligible kWh - Community Facility
Customers
17,877 Average PCE Payment per Eligible kWh $0.41
Total PCE Eligible kWh 65,455 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.70
Average Monthly PCE Eligible kWh per
Residential Customer
305 Last Reported PCE Level (per kWh)$0.41
Average Monthly PCE Eligible kWh per
Community Facility Customer
372 Effective Residential Rate (per kWh)$0.29
Average Monthly PCE Eligible Community
Facility kWh per Person
51 PCE Eligible kWh vs Total kWh Sold 38.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 194,978 Fuel Used (Gallons)21,523
Non-Diesel kWh Generated 0 Fuel Cost $72,315
Purchased kWh 0 Average Price of Fuel $3.36
Total Purchased & Generated 194,978 Fuel Cost per kWh sold $0.42
Annual Non-Fuel Expenses $41,916
Non-Fuel Expense per kWh Sold $0.25
Total Expense per kWh Sold $0.67
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 61,270 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
87.7%
Community Facility kWh Sold 18,045 Line Loss (%)11.0%
Other kWh Sold (Non-PCE)91,678 Fuel Efficiency (kWh per Gallon of Diesel)9.06
Total kWh Sold 170,993 PH Consumption as % of Generation 1.3%
Powerhouse (PH) Consumption kWh 2,523
Total kWh Sold & PH Consumption 173,516
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 86 of 187
Kasigluk PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 621
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 124
Community Facility Customers 12
Other Customers (Non-PCE)19
Fiscal Year PCE Payments $242,095
PCE Statistical Data
PCE Eligible kWh - Residential Customers 595,940 Average Annual PCE Payment per Eligible
Customer
$1,780
PCE Eligible kWh - Community Facility
Customers
290,926 Average PCE Payment per Eligible kWh $0.27
Total PCE Eligible kWh 886,866 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.55
Average Monthly PCE Eligible kWh per
Residential Customer
400 Last Reported PCE Level (per kWh)$0.27
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,020 Effective Residential Rate (per kWh)$0.28
Average Monthly PCE Eligible Community
Facility kWh per Person
39 PCE Eligible kWh vs Total kWh Sold 52.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,781,820 Fuel Used (Gallons)196,079
Non-Diesel kWh Generated 345,843 Fuel Cost $595,704
Purchased kWh 0 Average Price of Fuel $3.04
Total Purchased & Generated 3,127,663 Fuel Cost per kWh sold $0.35
Annual Non-Fuel Expenses $355,059
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.56
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 766,869 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
53.9%
Community Facility kWh Sold 387,098 Line Loss (%)42.7%
Other kWh Sold (Non-PCE)531,908 Fuel Efficiency (kWh per Gallon of Diesel)14.19
Total kWh Sold 1,685,875 PH Consumption as % of Generation 3.4%
Powerhouse (PH) Consumption kWh 104,990
Total kWh Sold & PH Consumption 1,790,865
Comments
Provides Power To Nunapitchuk Via Intertie
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 87 of 187
Kiana PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 421
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 112
Community Facility Customers 14
Other Customers (Non-PCE)24
Fiscal Year PCE Payments $233,751
PCE Statistical Data
PCE Eligible kWh - Residential Customers 484,455 Average Annual PCE Payment per Eligible
Customer
$1,855
PCE Eligible kWh - Community Facility
Customers
203,604 Average PCE Payment per Eligible kWh $0.34
Total PCE Eligible kWh 688,059 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.58
Average Monthly PCE Eligible kWh per
Residential Customer
360 Last Reported PCE Level (per kWh)$0.32
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,212 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
40 PCE Eligible kWh vs Total kWh Sold 43.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,695,620 Fuel Used (Gallons)117,719
Non-Diesel kWh Generated 0 Fuel Cost $402,541
Purchased kWh 0 Average Price of Fuel $3.42
Total Purchased & Generated 1,695,620 Fuel Cost per kWh sold $0.25
Annual Non-Fuel Expenses $334,447
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.46
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 708,977 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
93.7%
Community Facility kWh Sold 322,874 Line Loss (%)3.5%
Other kWh Sold (Non-PCE)556,158 Fuel Efficiency (kWh per Gallon of Diesel)14.40
Total kWh Sold 1,588,009 PH Consumption as % of Generation 2.8%
Powerhouse (PH) Consumption kWh 47,721
Total kWh Sold & PH Consumption 1,635,730
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 88 of 187
Kipnuk PCE
Utility: KIPNUK LIGHT PLANT
Reporting Period: 07/01/19..06/30/20
Community Population 669
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 190
Community Facility Customers 3
Other Customers (Non-PCE)37
Fiscal Year PCE Payments $396,766
PCE Statistical Data
PCE Eligible kWh - Residential Customers 737,463 Average Annual PCE Payment per Eligible
Customer
$2,056
PCE Eligible kWh - Community Facility
Customers
87,817 Average PCE Payment per Eligible kWh $0.48
Total PCE Eligible kWh 825,280 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.69
Average Monthly PCE Eligible kWh per
Residential Customer
323 Last Reported PCE Level (per kWh)$0.50
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,439 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per Person
11 PCE Eligible kWh vs Total kWh Sold 49.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,233,103 Fuel Used (Gallons)111,340
Non-Diesel kWh Generated 389,486 Fuel Cost $426,177
Purchased kWh 0 Average Price of Fuel $3.83
Total Purchased & Generated 1,622,589 Fuel Cost per kWh sold $0.26
Annual Non-Fuel Expenses $568,395
Non-Fuel Expense per kWh Sold $0.34
Total Expense per kWh Sold $0.60
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 826,209 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 87,817 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)748,044 Fuel Efficiency (kWh per Gallon of Diesel)11.08
Total kWh Sold 1,662,070 PH Consumption as % of Generation 2.6%
Powerhouse (PH) Consumption kWh 42,940
Total kWh Sold & PH Consumption 1,705,010
Comments
kWh's Generated & Powerhouse Consumption = 10 Months
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 89 of 187
Kivalina PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 442
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 92
Community Facility Customers 9
Other Customers (Non-PCE)24
Fiscal Year PCE Payments $167,923
PCE Statistical Data
PCE Eligible kWh - Residential Customers 414,646 Average Annual PCE Payment per Eligible
Customer
$1,663
PCE Eligible kWh - Community Facility
Customers
106,590 Average PCE Payment per Eligible kWh $0.32
Total PCE Eligible kWh 521,236 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.55
Average Monthly PCE Eligible kWh per
Residential Customer
376 Last Reported PCE Level (per kWh)$0.29
Average Monthly PCE Eligible kWh per
Community Facility Customer
987 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
20 PCE Eligible kWh vs Total kWh Sold 30.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,789,756 Fuel Used (Gallons)124,131
Non-Diesel kWh Generated 0 Fuel Cost $410,984
Purchased kWh 0 Average Price of Fuel $3.31
Total Purchased & Generated 1,789,756 Fuel Cost per kWh sold $0.24
Annual Non-Fuel Expenses $356,748
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.45
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 604,901 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
94.6%
Community Facility kWh Sold 294,134 Line Loss (%)2.6%
Other kWh Sold (Non-PCE)794,861 Fuel Efficiency (kWh per Gallon of Diesel)14.42
Total kWh Sold 1,693,896 PH Consumption as % of Generation 2.8%
Powerhouse (PH) Consumption kWh 49,336
Total kWh Sold & PH Consumption 1,743,232
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 90 of 187
Klawock PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/19..06/30/20
Community Population 777
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 396
Community Facility Customers 20
Other Customers (Non-PCE)135
Fiscal Year PCE Payments $30,765
PCE Statistical Data
PCE Eligible kWh - Residential Customers 1,540,658 Average Annual PCE Payment per Eligible
Customer
$74
PCE Eligible kWh - Community Facility
Customers
518,245 Average PCE Payment per Eligible kWh $0.01
Total PCE Eligible kWh 2,058,903 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.27
Average Monthly PCE Eligible kWh per
Residential Customer
324 Last Reported PCE Level (per kWh)$0.02
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,159 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
56 PCE Eligible kWh vs Total kWh Sold 26.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $0
Non-Fuel Expense per kWh Sold See Comments
Total Expense per kWh Sold $0.00
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 2,272,889 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 518,926 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)4,933,783 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 7,725,598 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 34,444
Total kWh Sold & PH Consumption 7,760,042
Comments
See Craig For Power Generation
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 91 of 187
Klukwan PCE
Utility: INSIDE PASSAGE ELECTRIC
Reporting Period: 07/01/19..06/30/20
Community Population 94
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 48
Community Facility Customers 7
Other Customers (Non-PCE)8
Fiscal Year PCE Payments $88,371
PCE Statistical Data
PCE Eligible kWh - Residential Customers 174,349 Average Annual PCE Payment per Eligible
Customer
$1,607
PCE Eligible kWh - Community Facility
Customers
78,960 Average PCE Payment per Eligible kWh $0.35
Total PCE Eligible kWh 253,309 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.60
Average Monthly PCE Eligible kWh per
Residential Customer
303 Last Reported PCE Level (per kWh)$0.33
Average Monthly PCE Eligible kWh per
Community Facility Customer
940 Effective Residential Rate (per kWh)$0.27
Average Monthly PCE Eligible Community
Facility kWh per Person
70 PCE Eligible kWh vs Total kWh Sold 57.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $147,942
Non-Fuel Expense per kWh Sold $0.34
Total Expense per kWh Sold $0.34
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 209,716 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 155,549 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)74,463 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 439,728 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 439,728
Comments
kWh's Generated For Power Sales Received From Chilkat Valley
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 92 of 187
Kobuk PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 144
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 39
Community Facility Customers 4
Other Customers (Non-PCE)15
Fiscal Year PCE Payments $111,731
PCE Statistical Data
PCE Eligible kWh - Residential Customers 169,512 Average Annual PCE Payment per Eligible
Customer
$2,598
PCE Eligible kWh - Community Facility
Customers
100,873 Average PCE Payment per Eligible kWh $0.41
Total PCE Eligible kWh 270,385 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.81
Average Monthly PCE Eligible kWh per
Residential Customer
362 Last Reported PCE Level (per kWh)$0.54
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,102 Effective Residential Rate (per kWh)$0.28
Average Monthly PCE Eligible Community
Facility kWh per Person
58 PCE Eligible kWh vs Total kWh Sold 41.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $136,973
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.21
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 240,783 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 164,253 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)245,334 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 650,370 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 650,370
Comments
Receives Power From Shungnak Bay Via Intertie
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 93 of 187
Kokhanok PCE
Utility: KOKHANOK VILLAGE COUNCIL
Reporting Period: 07/01/19..06/30/20
Community Population 168
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 55
Community Facility Customers 8
Other Customers (Non-PCE)14
Fiscal Year PCE Payments $166,080
PCE Statistical Data
PCE Eligible kWh - Residential Customers 179,419 Average Annual PCE Payment per Eligible
Customer
$2,636
PCE Eligible kWh - Community Facility
Customers
71,321 Average PCE Payment per Eligible kWh $0.66
Total PCE Eligible kWh 250,740 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.90
Average Monthly PCE Eligible kWh per
Residential Customer
272 Last Reported PCE Level (per kWh)$0.66
Average Monthly PCE Eligible kWh per
Community Facility Customer
743 Effective Residential Rate (per kWh)$0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
35 PCE Eligible kWh vs Total kWh Sold 65.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 484,859 Fuel Used (Gallons)40,415
Non-Diesel kWh Generated 0 Fuel Cost $207,931
Purchased kWh 0 Average Price of Fuel $5.14
Total Purchased & Generated 484,859 Fuel Cost per kWh sold $0.54
Annual Non-Fuel Expenses $61,682
Non-Fuel Expense per kWh Sold $0.16
Total Expense per kWh Sold $0.71
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 184,596 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
78.7%
Community Facility kWh Sold 71,321 Line Loss (%)9.9%
Other kWh Sold (Non-PCE)125,873 Fuel Efficiency (kWh per Gallon of Diesel)12.00
Total kWh Sold 381,790 PH Consumption as % of Generation 11.4%
Powerhouse (PH) Consumption kWh 55,122
Total kWh Sold & PH Consumption 436,912
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 94 of 187
Koliganek PCE
Utility: NEW KOLIGANEK VILLAGE COUNCIL
Reporting Period: 07/01/19..06/30/20
Community Population 205
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 78
Community Facility Customers 12
Other Customers (Non-PCE)16
Fiscal Year PCE Payments $80,926
PCE Statistical Data
PCE Eligible kWh - Residential Customers 212,722 Average Annual PCE Payment per Eligible
Customer
$899
PCE Eligible kWh - Community Facility
Customers
72,051 Average PCE Payment per Eligible kWh $0.28
Total PCE Eligible kWh 284,773 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.50
Average Monthly PCE Eligible kWh per
Residential Customer
227 Last Reported PCE Level (per kWh)$0.27
Average Monthly PCE Eligible kWh per
Community Facility Customer
500 Effective Residential Rate (per kWh)$0.23
Average Monthly PCE Eligible Community
Facility kWh per Person
29 PCE Eligible kWh vs Total kWh Sold 46.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 696,455 Fuel Used (Gallons)57,124
Non-Diesel kWh Generated 0 Fuel Cost $190,349
Purchased kWh 0 Average Price of Fuel $3.33
Total Purchased & Generated 696,455 Fuel Cost per kWh sold $0.31
Annual Non-Fuel Expenses $0
Non-Fuel Expense per kWh Sold See Comments
Total Expense per kWh Sold $0.31
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 260,103 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
87.8%
Community Facility kWh Sold 72,051 Line Loss (%)9.5%
Other kWh Sold (Non-PCE)279,642 Fuel Efficiency (kWh per Gallon of Diesel)12.19
Total kWh Sold 611,796 PH Consumption as % of Generation 2.7%
Powerhouse (PH) Consumption kWh 18,726
Total kWh Sold & PH Consumption 630,522
Comments
Non-fuel Costs Not Reported
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 95 of 187
Kongiganak PCE
Utility: PUVURNAQ POWER COMPANY
Reporting Period: 07/01/19..06/30/20
Community Population 539
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 159
Community Facility Customers 5
Other Customers (Non-PCE)25
Fiscal Year PCE Payments $164,238
PCE Statistical Data
PCE Eligible kWh - Residential Customers 447,659 Average Annual PCE Payment per Eligible
Customer
$1,001
PCE Eligible kWh - Community Facility
Customers
68,754 Average PCE Payment per Eligible kWh $0.32
Total PCE Eligible kWh 516,413 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.65
Average Monthly PCE Eligible kWh per
Residential Customer
235 Last Reported PCE Level (per kWh)$0.32
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,146 Effective Residential Rate (per kWh)$0.33
Average Monthly PCE Eligible Community
Facility kWh per Person
11 PCE Eligible kWh vs Total kWh Sold 49.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 731,780 Fuel Used (Gallons)63,318
Non-Diesel kWh Generated 591,410 Fuel Cost $194,483
Purchased kWh 0 Average Price of Fuel $3.07
Total Purchased & Generated 1,323,190 Fuel Cost per kWh sold $0.19
Annual Non-Fuel Expenses $426,001
Non-Fuel Expense per kWh Sold $0.41
Total Expense per kWh Sold $0.59
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 636,161 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
79.0%
Community Facility kWh Sold 68,754 Line Loss (%)11.1%
Other kWh Sold (Non-PCE)340,226 Fuel Efficiency (kWh per Gallon of Diesel)11.56
Total kWh Sold 1,045,141 PH Consumption as % of Generation 9.9%
Powerhouse (PH) Consumption kWh 131,636
Total kWh Sold & PH Consumption 1,176,777
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 96 of 187
Kotlik PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 655
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 127
Community Facility Customers 10
Other Customers (Non-PCE)34
Fiscal Year PCE Payments $247,175
PCE Statistical Data
PCE Eligible kWh - Residential Customers 566,380 Average Annual PCE Payment per Eligible
Customer
$1,804
PCE Eligible kWh - Community Facility
Customers
198,826 Average PCE Payment per Eligible kWh $0.32
Total PCE Eligible kWh 765,206 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.58
Average Monthly PCE Eligible kWh per
Residential Customer
372 Last Reported PCE Level (per kWh)$0.31
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,657 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
25 PCE Eligible kWh vs Total kWh Sold 38.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,106,005 Fuel Used (Gallons)162,194
Non-Diesel kWh Generated 0 Fuel Cost $507,397
Purchased kWh 0 Average Price of Fuel $3.13
Total Purchased & Generated 2,106,005 Fuel Cost per kWh sold $0.26
Annual Non-Fuel Expenses $417,035
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.47
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 739,384 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
94.0%
Community Facility kWh Sold 265,627 Line Loss (%)3.8%
Other kWh Sold (Non-PCE)975,137 Fuel Efficiency (kWh per Gallon of Diesel)12.98
Total kWh Sold 1,980,148 PH Consumption as % of Generation 2.1%
Powerhouse (PH) Consumption kWh 44,802
Total kWh Sold & PH Consumption 2,024,950
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 97 of 187
Kotzebue PCE
Utility: KOTZEBUE ELECTRIC ASSOCIATION
Reporting Period: 07/01/19..06/30/20
Community Population 3121
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 1,141
Community Facility Customers 26
Other Customers (Non-PCE)105
Fiscal Year PCE Payments $970,867
PCE Statistical Data
PCE Eligible kWh - Residential Customers 3,597,688 Average Annual PCE Payment per Eligible
Customer
$832
PCE Eligible kWh - Community Facility
Customers
1,632,934 Average PCE Payment per Eligible kWh $0.19
Total PCE Eligible kWh 5,230,622 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.41
Average Monthly PCE Eligible kWh per
Residential Customer
263 Last Reported PCE Level (per kWh)$0.19
Average Monthly PCE Eligible kWh per
Community Facility Customer
5,234 Effective Residential Rate (per kWh)$0.22
Average Monthly PCE Eligible Community
Facility kWh per Person
44 PCE Eligible kWh vs Total kWh Sold 27.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 17,990,980 Fuel Used (Gallons)1,227,703
Non-Diesel kWh Generated 3,560,316 Fuel Cost $3,031,142
Purchased kWh 0 Average Price of Fuel $2.47
Total Purchased & Generated 21,551,296 Fuel Cost per kWh sold $0.16
Annual Non-Fuel Expenses $3,611,073
Non-Fuel Expense per kWh Sold $0.19
Total Expense per kWh Sold $0.35
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 6,772,151 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
87.5%
Community Facility kWh Sold 1,632,934 Line Loss (%)10.2%
Other kWh Sold (Non-PCE)10,457,755 Fuel Efficiency (kWh per Gallon of Diesel)14.65
Total kWh Sold 18,862,840 PH Consumption as % of Generation 2.2%
Powerhouse (PH) Consumption kWh 483,061
Total kWh Sold & PH Consumption 19,345,901
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 98 of 187
Koyuk PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 350
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 86
Community Facility Customers 10
Other Customers (Non-PCE)31
Fiscal Year PCE Payments $173,404
PCE Statistical Data
PCE Eligible kWh - Residential Customers 369,419 Average Annual PCE Payment per Eligible
Customer
$1,806
PCE Eligible kWh - Community Facility
Customers
160,055 Average PCE Payment per Eligible kWh $0.33
Total PCE Eligible kWh 529,474 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.58
Average Monthly PCE Eligible kWh per
Residential Customer
358 Last Reported PCE Level (per kWh)$0.31
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,334 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
38 PCE Eligible kWh vs Total kWh Sold 44.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,271,415 Fuel Used (Gallons)91,984
Non-Diesel kWh Generated 0 Fuel Cost $298,871
Purchased kWh 0 Average Price of Fuel $3.25
Total Purchased & Generated 1,271,415 Fuel Cost per kWh sold $0.25
Annual Non-Fuel Expenses $252,259
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.46
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 489,791 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
94.2%
Community Facility kWh Sold 255,508 Line Loss (%)4.2%
Other kWh Sold (Non-PCE)452,469 Fuel Efficiency (kWh per Gallon of Diesel)13.82
Total kWh Sold 1,197,768 PH Consumption as % of Generation 1.6%
Powerhouse (PH) Consumption kWh 19,958
Total kWh Sold & PH Consumption 1,217,726
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 99 of 187
Koyukuk PCE
Utility: CITY OF KOYUKUK
Reporting Period: 07/01/19..06/30/20
Community Population 86
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 56
Community Facility Customers 4
Other Customers (Non-PCE)11
Fiscal Year PCE Payments $35,409
PCE Statistical Data
PCE Eligible kWh - Residential Customers 89,102 Average Annual PCE Payment per Eligible
Customer
$590
PCE Eligible kWh - Community Facility
Customers
10,500 Average PCE Payment per Eligible kWh $0.36
Total PCE Eligible kWh 99,602 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.95
Average Monthly PCE Eligible kWh per
Residential Customer
133 Last Reported PCE Level (per kWh)$0.36
Average Monthly PCE Eligible kWh per
Community Facility Customer
219 Effective Residential Rate (per kWh)$0.59
Average Monthly PCE Eligible Community
Facility kWh per Person
10 PCE Eligible kWh vs Total kWh Sold 47.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 113,311 Fuel Used (Gallons)34,011
Non-Diesel kWh Generated 0 Fuel Cost $113,855
Purchased kWh 0 Average Price of Fuel $3.35
Total Purchased & Generated 113,311 Fuel Cost per kWh sold $0.54
Annual Non-Fuel Expenses $0
Non-Fuel Expense per kWh Sold See Comments
Total Expense per kWh Sold $0.54
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 99,447 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 10,500 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)99,710 Fuel Efficiency (kWh per Gallon of Diesel)3.33
Total kWh Sold 209,657 PH Consumption as % of Generation 5.4%
Powerhouse (PH) Consumption kWh 6,069
Total kWh Sold & PH Consumption 215,726
Comments
Non-fuel Costs Not Reported. Utility Unable To Verify Plant Meter Readings.
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 100 of 187
Kwethluk PCE
Utility: KWETHLUK INCORPORATED
Reporting Period: 07/01/19..06/30/20
Community Population 819
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 187
Community Facility Customers 2
Other Customers (Non-PCE)48
Fiscal Year PCE Payments $199,528
PCE Statistical Data
PCE Eligible kWh - Residential Customers 688,550 Average Annual PCE Payment per Eligible
Customer
$1,056
PCE Eligible kWh - Community Facility
Customers
10,309 Average PCE Payment per Eligible kWh $0.29
Total PCE Eligible kWh 698,859 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.52
Average Monthly PCE Eligible kWh per
Residential Customer
307 Last Reported PCE Level (per kWh)$0.32
Average Monthly PCE Eligible kWh per
Community Facility Customer
430 Effective Residential Rate (per kWh)$0.20
Average Monthly PCE Eligible Community
Facility kWh per Person
1 PCE Eligible kWh vs Total kWh Sold 41.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,914,839 Fuel Used (Gallons)154,099
Non-Diesel kWh Generated 0 Fuel Cost $617,666
Purchased kWh 0 Average Price of Fuel $4.01
Total Purchased & Generated 1,914,839 Fuel Cost per kWh sold $0.37
Annual Non-Fuel Expenses $152,576
Non-Fuel Expense per kWh Sold $0.09
Total Expense per kWh Sold $0.46
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 845,922 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
88.3%
Community Facility kWh Sold 10,309 Line Loss (%)9.2%
Other kWh Sold (Non-PCE)834,579 Fuel Efficiency (kWh per Gallon of Diesel)12.43
Total kWh Sold 1,690,810 PH Consumption as % of Generation 2.5%
Powerhouse (PH) Consumption kWh 48,747
Total kWh Sold & PH Consumption 1,739,557
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 101 of 187
Kwigillingok PCE
Utility: KWIGILLINGOK IRA COUNCIL
Reporting Period: 07/01/19..06/30/20
Community Population 381
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 100
Community Facility Customers 3
Other Customers (Non-PCE)24
Fiscal Year PCE Payments $170,831
PCE Statistical Data
PCE Eligible kWh - Residential Customers 426,750 Average Annual PCE Payment per Eligible
Customer
$1,659
PCE Eligible kWh - Community Facility
Customers
37,076 Average PCE Payment per Eligible kWh $0.37
Total PCE Eligible kWh 463,826 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.67
Average Monthly PCE Eligible kWh per
Residential Customer
356 Last Reported PCE Level (per kWh)$0.37
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,030 Effective Residential Rate (per kWh)$0.30
Average Monthly PCE Eligible Community
Facility kWh per Person
8 PCE Eligible kWh vs Total kWh Sold 40.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,055,090 Fuel Used (Gallons)80,557
Non-Diesel kWh Generated 267,768 Fuel Cost $268,913
Purchased kWh 0 Average Price of Fuel $3.34
Total Purchased & Generated 1,322,858 Fuel Cost per kWh sold $0.24
Annual Non-Fuel Expenses $426,773
Non-Fuel Expense per kWh Sold $0.37
Total Expense per kWh Sold $0.61
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 529,359 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
86.2%
Community Facility kWh Sold 37,076 Line Loss (%)8.8%
Other kWh Sold (Non-PCE)573,673 Fuel Efficiency (kWh per Gallon of Diesel)13.10
Total kWh Sold 1,140,108 PH Consumption as % of Generation 5.0%
Powerhouse (PH) Consumption kWh 66,396
Total kWh Sold & PH Consumption 1,206,504
Comments
Fuel Gallons Used & Fuel Costs = 11 Months
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 102 of 187
Larsen Bay PCE
Utility: LARSEN BAY UTILITY COMPANY
Reporting Period: 07/01/19..06/30/20
Community Population 80
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 52
Community Facility Customers 12
Other Customers (Non-PCE)31
Fiscal Year PCE Payments $0
PCE Statistical Data
PCE Eligible kWh - Residential Customers 89,147 Average Annual PCE Payment per Eligible
Customer
$0
PCE Eligible kWh - Community Facility
Customers
64,999 Average PCE Payment per Eligible kWh $0.00
Total PCE Eligible kWh 154,146 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.41
Average Monthly PCE Eligible kWh per
Residential Customer
143 Last Reported PCE Level (per kWh)$0.00
Average Monthly PCE Eligible kWh per
Community Facility Customer
451 Effective Residential Rate (per kWh)$0.41
Average Monthly PCE Eligible Community
Facility kWh per Person
68 PCE Eligible kWh vs Total kWh Sold 23.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 63,607 Fuel Used (Gallons)5,278
Non-Diesel kWh Generated 748,696 Fuel Cost $18,527
Purchased kWh 0 Average Price of Fuel $3.51
Total Purchased & Generated 812,303 Fuel Cost per kWh sold $0.03
Annual Non-Fuel Expenses $38,400
Non-Fuel Expense per kWh Sold $0.06
Total Expense per kWh Sold $0.09
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 122,456 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
80.8%
Community Facility kWh Sold 150,196 Line Loss (%)12.4%
Other kWh Sold (Non-PCE)383,814 Fuel Efficiency (kWh per Gallon of Diesel)12.05
Total kWh Sold 656,466 PH Consumption as % of Generation 6.8%
Powerhouse (PH) Consumption kWh 55,382
Total kWh Sold & PH Consumption 711,848
Comments
No Disbursements To Utility. PCE Levels = $0.00 Per Eligible kWh
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 103 of 187
Levelock PCE
Utility: LEVELOCK ELECTRICAL COOP
Reporting Period: 07/01/19..06/30/20
Community Population 81
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 40
Community Facility Customers 8
Other Customers (Non-PCE)30
Fiscal Year PCE Payments $66,360
PCE Statistical Data
PCE Eligible kWh - Residential Customers 100,840 Average Annual PCE Payment per Eligible
Customer
$1,383
PCE Eligible kWh - Community Facility
Customers
32,620 Average PCE Payment per Eligible kWh $0.50
Total PCE Eligible kWh 133,460 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.85
Average Monthly PCE Eligible kWh per
Residential Customer
210 Last Reported PCE Level (per kWh)$0.47
Average Monthly PCE Eligible kWh per
Community Facility Customer
340 Effective Residential Rate (per kWh)$0.38
Average Monthly PCE Eligible Community
Facility kWh per Person
34 PCE Eligible kWh vs Total kWh Sold 39.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 426,685 Fuel Used (Gallons)39,567
Non-Diesel kWh Generated 0 Fuel Cost $129,547
Purchased kWh 0 Average Price of Fuel $3.27
Total Purchased & Generated 426,685 Fuel Cost per kWh sold $0.38
Annual Non-Fuel Expenses $85,769
Non-Fuel Expense per kWh Sold $0.25
Total Expense per kWh Sold $0.64
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 121,498 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
78.9%
Community Facility kWh Sold 32,620 Line Loss (%)13.5%
Other kWh Sold (Non-PCE)182,425 Fuel Efficiency (kWh per Gallon of Diesel)10.78
Total kWh Sold 336,543 PH Consumption as % of Generation 7.7%
Powerhouse (PH) Consumption kWh 32,727
Total kWh Sold & PH Consumption 369,270
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 104 of 187
Lime Village PCE
Utility: LIME VILLAGE ELECTRIC UTILITY
Reporting Period: 07/01/19..06/30/20
Community Population 15
Last Reported Month January
No. of Monthly Payments Made 6
Residential Customers 12
Community Facility Customers 6
Other Customers (Non-PCE)2
Fiscal Year PCE Payments $7,502
PCE Statistical Data
PCE Eligible kWh - Residential Customers 5,429 Average Annual PCE Payment per Eligible
Customer
$417
PCE Eligible kWh - Community Facility
Customers
4,332 Average PCE Payment per Eligible kWh $0.77
Total PCE Eligible kWh 9,761 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.77
Average Monthly PCE Eligible kWh per
Residential Customer
75 Last Reported PCE Level (per kWh)$0.77
Average Monthly PCE Eligible kWh per
Community Facility Customer
120 Effective Residential Rate (per kWh)$1.00
Average Monthly PCE Eligible Community
Facility kWh per Person
48 PCE Eligible kWh vs Total kWh Sold 37.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 36,105 Fuel Used (Gallons)4,815
Non-Diesel kWh Generated 0 Fuel Cost $34,090
Purchased kWh 0 Average Price of Fuel $7.08
Total Purchased & Generated 36,105 Fuel Cost per kWh sold $1.29
Annual Non-Fuel Expenses $0
Non-Fuel Expense per kWh Sold See Comments
Total Expense per kWh Sold $1.29
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 9,254 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
72.9%
Community Facility kWh Sold 5,480 Line Loss (%)23.8%
Other kWh Sold (Non-PCE)11,593 Fuel Efficiency (kWh per Gallon of Diesel)7.50
Total kWh Sold 26,327 PH Consumption as % of Generation 3.3%
Powerhouse (PH) Consumption kWh 1,181
Total kWh Sold & PH Consumption 27,508
Comments
Utility Only Reported Data For 6 Months. Non-Fuel Costs Not Reported.
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 105 of 187
Lower Kalskag PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 275
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 86
Community Facility Customers 7
Other Customers (Non-PCE)11
Fiscal Year PCE Payments $106,470
PCE Statistical Data
PCE Eligible kWh - Residential Customers 285,350 Average Annual PCE Payment per Eligible
Customer
$1,145
PCE Eligible kWh - Community Facility
Customers
79,844 Average PCE Payment per Eligible kWh $0.29
Total PCE Eligible kWh 365,194 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.55
Average Monthly PCE Eligible kWh per
Residential Customer
277 Last Reported PCE Level (per kWh)$0.28
Average Monthly PCE Eligible kWh per
Community Facility Customer
951 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
24 PCE Eligible kWh vs Total kWh Sold 53.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $144,435
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.21
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 322,692 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 230,090 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)133,019 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 685,801 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 685,801
Comments
Power Is From Upper Kalskag Via Intertie. See Upper Kalskag For Fuel Cost.
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 106 of 187
Manley Hot Springs PCE
Utility: TDX MANLEY GENERATING LLC
Reporting Period: 07/01/19..06/30/20
Community Population 114
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 80
Community Facility Customers 17
Other Customers (Non-PCE)16
Fiscal Year PCE Payments $140,281
PCE Statistical Data
PCE Eligible kWh - Residential Customers 144,082 Average Annual PCE Payment per Eligible
Customer
$1,446
PCE Eligible kWh - Community Facility
Customers
41,414 Average PCE Payment per Eligible kWh $0.76
Total PCE Eligible kWh 185,496 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.99
Average Monthly PCE Eligible kWh per
Residential Customer
150 Last Reported PCE Level (per kWh)$0.73
Average Monthly PCE Eligible kWh per
Community Facility Customer
203 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
30 PCE Eligible kWh vs Total kWh Sold 41.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 572,339 Fuel Used (Gallons)45,240
Non-Diesel kWh Generated 0 Fuel Cost $129,605
Purchased kWh 0 Average Price of Fuel $2.86
Total Purchased & Generated 572,339 Fuel Cost per kWh sold $0.29
Annual Non-Fuel Expenses $0
Non-Fuel Expense per kWh Sold See Comments
Total Expense per kWh Sold $0.29
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 163,253 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
78.6%
Community Facility kWh Sold 45,467 Line Loss (%)17.3%
Other kWh Sold (Non-PCE)241,264 Fuel Efficiency (kWh per Gallon of Diesel)12.65
Total kWh Sold 449,984 PH Consumption as % of Generation 4.1%
Powerhouse (PH) Consumption kWh 23,579
Total kWh Sold & PH Consumption 473,563
Comments
Non-Fuel Costs Not Reported
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 107 of 187
Manokotak PCE
Utility: MANOKOTAK POWER COMPANY
Reporting Period: 07/01/19..06/30/20
Community Population 508
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 135
Community Facility Customers 5
Other Customers (Non-PCE)38
Fiscal Year PCE Payments $131,373
PCE Statistical Data
PCE Eligible kWh - Residential Customers 521,063 Average Annual PCE Payment per Eligible
Customer
$938
PCE Eligible kWh - Community Facility
Customers
60,067 Average PCE Payment per Eligible kWh $0.23
Total PCE Eligible kWh 581,130 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.60
Average Monthly PCE Eligible kWh per
Residential Customer
322 Last Reported PCE Level (per kWh)$0.21
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,001 Effective Residential Rate (per kWh)$0.39
Average Monthly PCE Eligible Community
Facility kWh per Person
10 PCE Eligible kWh vs Total kWh Sold 54.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,231,141 Fuel Used (Gallons)85,711
Non-Diesel kWh Generated 0 Fuel Cost $243,888
Purchased kWh 0 Average Price of Fuel $2.85
Total Purchased & Generated 1,231,141 Fuel Cost per kWh sold $0.23
Annual Non-Fuel Expenses $363,187
Non-Fuel Expense per kWh Sold $0.34
Total Expense per kWh Sold $0.56
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 594,869 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
87.5%
Community Facility kWh Sold 60,067 Line Loss (%)3.7%
Other kWh Sold (Non-PCE)422,110 Fuel Efficiency (kWh per Gallon of Diesel)14.36
Total kWh Sold 1,077,046 PH Consumption as % of Generation 8.8%
Powerhouse (PH) Consumption kWh 108,152
Total kWh Sold & PH Consumption 1,185,198
Comments
kWh's Generated & Powerhouse Consumption = 11 Months
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 108 of 187
Marshall PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 437
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 102
Community Facility Customers 19
Other Customers (Non-PCE)21
Fiscal Year PCE Payments $191,736
PCE Statistical Data
PCE Eligible kWh - Residential Customers 475,870 Average Annual PCE Payment per Eligible
Customer
$1,585
PCE Eligible kWh - Community Facility
Customers
196,672 Average PCE Payment per Eligible kWh $0.29
Total PCE Eligible kWh 672,542 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.53
Average Monthly PCE Eligible kWh per
Residential Customer
389 Last Reported PCE Level (per kWh)$0.27
Average Monthly PCE Eligible kWh per
Community Facility Customer
863 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
38 PCE Eligible kWh vs Total kWh Sold 48.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,486,540 Fuel Used (Gallons)118,256
Non-Diesel kWh Generated 0 Fuel Cost $343,203
Purchased kWh 0 Average Price of Fuel $2.90
Total Purchased & Generated 1,486,540 Fuel Cost per kWh sold $0.25
Annual Non-Fuel Expenses $293,580
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.46
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 591,196 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
93.8%
Community Facility kWh Sold 309,083 Line Loss (%)4.2%
Other kWh Sold (Non-PCE)493,684 Fuel Efficiency (kWh per Gallon of Diesel)12.57
Total kWh Sold 1,393,963 PH Consumption as % of Generation 2.1%
Powerhouse (PH) Consumption kWh 30,733
Total kWh Sold & PH Consumption 1,424,696
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 109 of 187
McGrath PCE
Utility: MCGRATH LIGHT & POWER
Reporting Period: 07/01/19..06/30/20
Community Population 310
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 171
Community Facility Customers 13
Other Customers (Non-PCE)82
Fiscal Year PCE Payments $246,595
PCE Statistical Data
PCE Eligible kWh - Residential Customers 460,846 Average Annual PCE Payment per Eligible
Customer
$1,340
PCE Eligible kWh - Community Facility
Customers
176,111 Average PCE Payment per Eligible kWh $0.39
Total PCE Eligible kWh 636,957 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.79
Average Monthly PCE Eligible kWh per
Residential Customer
225 Last Reported PCE Level (per kWh)$0.39
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,129 Effective Residential Rate (per kWh)$0.40
Average Monthly PCE Eligible Community
Facility kWh per Person
47 PCE Eligible kWh vs Total kWh Sold 32.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,252,330 Fuel Used (Gallons)165,414
Non-Diesel kWh Generated 0 Fuel Cost $588,971
Purchased kWh 0 Average Price of Fuel $3.56
Total Purchased & Generated 2,252,330 Fuel Cost per kWh sold $0.30
Annual Non-Fuel Expenses $0
Non-Fuel Expense per kWh Sold See Comments
Total Expense per kWh Sold $0.30
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 527,238 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
87.4%
Community Facility kWh Sold 176,111 Line Loss (%)8.5%
Other kWh Sold (Non-PCE)1,265,775 Fuel Efficiency (kWh per Gallon of Diesel)13.62
Total kWh Sold 1,969,124 PH Consumption as % of Generation 4.0%
Powerhouse (PH) Consumption kWh 90,997
Total kWh Sold & PH Consumption 2,060,121
Comments
Non-Fuel Costs Not Reported
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 110 of 187
Mekoryuk PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 223
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 87
Community Facility Customers 12
Other Customers (Non-PCE)28
Fiscal Year PCE Payments $113,173
PCE Statistical Data
PCE Eligible kWh - Residential Customers 272,470 Average Annual PCE Payment per Eligible
Customer
$1,143
PCE Eligible kWh - Community Facility
Customers
100,436 Average PCE Payment per Eligible kWh $0.30
Total PCE Eligible kWh 372,906 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.57
Average Monthly PCE Eligible kWh per
Residential Customer
261 Last Reported PCE Level (per kWh)$0.29
Average Monthly PCE Eligible kWh per
Community Facility Customer
697 Effective Residential Rate (per kWh)$0.28
Average Monthly PCE Eligible Community
Facility kWh per Person
38 PCE Eligible kWh vs Total kWh Sold 47.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 848,795 Fuel Used (Gallons)65,572
Non-Diesel kWh Generated 38,066 Fuel Cost $197,069
Purchased kWh 0 Average Price of Fuel $3.01
Total Purchased & Generated 886,861 Fuel Cost per kWh sold $0.25
Annual Non-Fuel Expenses $167,275
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.46
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 287,879 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
89.6%
Community Facility kWh Sold 166,861 Line Loss (%)5.3%
Other kWh Sold (Non-PCE)339,510 Fuel Efficiency (kWh per Gallon of Diesel)12.94
Total kWh Sold 794,250 PH Consumption as % of Generation 5.2%
Powerhouse (PH) Consumption kWh 45,707
Total kWh Sold & PH Consumption 839,957
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 111 of 187
Mentasta PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/19..06/30/20
Community Population 128
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 48
Community Facility Customers 4
Other Customers (Non-PCE)20
Fiscal Year PCE Payments $45,231
PCE Statistical Data
PCE Eligible kWh - Residential Customers 132,630 Average Annual PCE Payment per Eligible
Customer
$870
PCE Eligible kWh - Community Facility
Customers
18,113 Average PCE Payment per Eligible kWh $0.30
Total PCE Eligible kWh 150,743 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.56
Average Monthly PCE Eligible kWh per
Residential Customer
230 Last Reported PCE Level (per kWh)$0.26
Average Monthly PCE Eligible kWh per
Community Facility Customer
377 Effective Residential Rate (per kWh)$0.30
Average Monthly PCE Eligible Community
Facility kWh per Person
12 PCE Eligible kWh vs Total kWh Sold 38.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $0
Non-Fuel Expense per kWh Sold See Comments
Total Expense per kWh Sold $0.00
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 140,059 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 18,113 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)235,737 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 393,909 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 393,909
Comments
See Slana For Power Generation
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 112 of 187
Minto PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 208
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 74
Community Facility Customers 7
Other Customers (Non-PCE)17
Fiscal Year PCE Payments $105,576
PCE Statistical Data
PCE Eligible kWh - Residential Customers 230,760 Average Annual PCE Payment per Eligible
Customer
$1,303
PCE Eligible kWh - Community Facility
Customers
157,559 Average PCE Payment per Eligible kWh $0.27
Total PCE Eligible kWh 388,319 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.53
Average Monthly PCE Eligible kWh per
Residential Customer
260 Last Reported PCE Level (per kWh)$0.27
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,876 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
63 PCE Eligible kWh vs Total kWh Sold 61.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 664,587 Fuel Used (Gallons)40,815
Non-Diesel kWh Generated 0 Fuel Cost $102,931
Purchased kWh 0 Average Price of Fuel $2.52
Total Purchased & Generated 664,587 Fuel Cost per kWh sold $0.16
Annual Non-Fuel Expenses $132,860
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.37
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 297,276 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
94.9%
Community Facility kWh Sold 254,546 Line Loss (%)3.1%
Other kWh Sold (Non-PCE)79,019 Fuel Efficiency (kWh per Gallon of Diesel)16.28
Total kWh Sold 630,841 PH Consumption as % of Generation 1.9%
Powerhouse (PH) Consumption kWh 12,888
Total kWh Sold & PH Consumption 643,729
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 113 of 187
Mt. Village PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 804
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 176
Community Facility Customers 18
Other Customers (Non-PCE)46
Fiscal Year PCE Payments $319,418
PCE Statistical Data
PCE Eligible kWh - Residential Customers 756,937 Average Annual PCE Payment per Eligible
Customer
$1,646
PCE Eligible kWh - Community Facility
Customers
273,544 Average PCE Payment per Eligible kWh $0.31
Total PCE Eligible kWh 1,030,481 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.56
Average Monthly PCE Eligible kWh per
Residential Customer
358 Last Reported PCE Level (per kWh)$0.29
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,266 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
28 PCE Eligible kWh vs Total kWh Sold 40.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,704,549 Fuel Used (Gallons)188,137
Non-Diesel kWh Generated 0 Fuel Cost $597,073
Purchased kWh 0 Average Price of Fuel $3.17
Total Purchased & Generated 2,704,549 Fuel Cost per kWh sold $0.24
Annual Non-Fuel Expenses $532,930
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.45
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 923,144 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
93.6%
Community Facility kWh Sold 483,464 Line Loss (%)4.6%
Other kWh Sold (Non-PCE)1,123,830 Fuel Efficiency (kWh per Gallon of Diesel)14.38
Total kWh Sold 2,530,438 PH Consumption as % of Generation 1.9%
Powerhouse (PH) Consumption kWh 50,228
Total kWh Sold & PH Consumption 2,580,666
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 114 of 187
Naknek;S.Naknek;Kng Slmn PCE
Utility: NAKNEK ELECTRIC
Reporting Period: 07/01/19..06/30/20
Community Population 879
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 734
Community Facility Customers 37
Other Customers (Non-PCE)409
Fiscal Year PCE Payments $737,234
PCE Statistical Data
PCE Eligible kWh - Residential Customers 1,864,563 Average Annual PCE Payment per Eligible
Customer
$956
PCE Eligible kWh - Community Facility
Customers
738,360 Average PCE Payment per Eligible kWh $0.28
Total PCE Eligible kWh 2,602,923 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.50
Average Monthly PCE Eligible kWh per
Residential Customer
212 Last Reported PCE Level (per kWh)$0.28
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,663 Effective Residential Rate (per kWh)$0.22
Average Monthly PCE Eligible Community
Facility kWh per Person
70 PCE Eligible kWh vs Total kWh Sold 12.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 22,435,964 Fuel Used (Gallons)1,512,978
Non-Diesel kWh Generated 0 Fuel Cost $3,671,048
Purchased kWh 0 Average Price of Fuel $2.43
Total Purchased & Generated 22,435,964 Fuel Cost per kWh sold $0.18
Annual Non-Fuel Expenses $3,716,753
Non-Fuel Expense per kWh Sold $0.18
Total Expense per kWh Sold $0.36
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 3,153,839 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
90.4%
Community Facility kWh Sold 1,151,800 Line Loss (%)7.5%
Other kWh Sold (Non-PCE)15,984,951 Fuel Efficiency (kWh per Gallon of Diesel)14.83
Total kWh Sold 20,290,590 PH Consumption as % of Generation 2.0%
Powerhouse (PH) Consumption kWh 455,903
Total kWh Sold & PH Consumption 20,746,493
Comments
Non-Fuel Costs = 9 Months
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 115 of 187
Napakiak PCE
Utility: NAPAKIAK IRCINRAQ
Reporting Period: 07/01/19..06/30/20
Community Population 344
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 108
Community Facility Customers 4
Other Customers (Non-PCE)23
Fiscal Year PCE Payments $150,359
PCE Statistical Data
PCE Eligible kWh - Residential Customers 341,698 Average Annual PCE Payment per Eligible
Customer
$1,342
PCE Eligible kWh - Community Facility
Customers
38,040 Average PCE Payment per Eligible kWh $0.40
Total PCE Eligible kWh 379,738 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.80
Average Monthly PCE Eligible kWh per
Residential Customer
264 Last Reported PCE Level (per kWh)$0.39
Average Monthly PCE Eligible kWh per
Community Facility Customer
793 Effective Residential Rate (per kWh)$0.42
Average Monthly PCE Eligible Community
Facility kWh per Person
9 PCE Eligible kWh vs Total kWh Sold 49.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 776,021 Average Price of Fuel $0.00
Total Purchased & Generated 776,021 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $97,432
Non-Fuel Expense per kWh Sold $0.13
Total Expense per kWh Sold $0.13
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 362,868 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
98.3%
Community Facility kWh Sold 38,338 Line Loss (%)1.7%
Other kWh Sold (Non-PCE)361,360 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 762,566 PH Consumption as % of Generation 0.0%
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 762,566
Comments
Non-Fuel Costs = 10 Months. Powerhouse Consumption Not Reported.
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 116 of 187
Napaskiak PCE
Utility: NAPASKIAK ELECTRIC UTILITY
Reporting Period: 07/01/19..06/30/20
Community Population 433
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 111
Community Facility Customers 8
Other Customers (Non-PCE)34
Fiscal Year PCE Payments $81,158
PCE Statistical Data
PCE Eligible kWh - Residential Customers 359,265 Average Annual PCE Payment per Eligible
Customer
$682
PCE Eligible kWh - Community Facility
Customers
36,092 Average PCE Payment per Eligible kWh $0.21
Total PCE Eligible kWh 395,357 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.70
Average Monthly PCE Eligible kWh per
Residential Customer
270 Last Reported PCE Level (per kWh)$0.20
Average Monthly PCE Eligible kWh per
Community Facility Customer
376 Effective Residential Rate (per kWh)$0.50
Average Monthly PCE Eligible Community
Facility kWh per Person
7 PCE Eligible kWh vs Total kWh Sold 61.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 581,641 Fuel Used (Gallons)64,938
Non-Diesel kWh Generated 0 Fuel Cost $205,446
Purchased kWh 0 Average Price of Fuel $3.16
Total Purchased & Generated 581,641 Fuel Cost per kWh sold $0.32
Annual Non-Fuel Expenses $124,465
Non-Fuel Expense per kWh Sold $0.19
Total Expense per kWh Sold $0.51
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 370,299 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 36,092 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)235,576 Fuel Efficiency (kWh per Gallon of Diesel)8.96
Total kWh Sold 641,967 PH Consumption as % of Generation 3.5%
Powerhouse (PH) Consumption kWh 20,568
Total kWh Sold & PH Consumption 662,535
Comments
kWh's Generated & Powerhouse Consumption = 9 Months
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 117 of 187
Naukati PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/19..06/30/20
Community Population 124
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 95
Community Facility Customers 0
Other Customers (Non-PCE)15
Fiscal Year PCE Payments $4,610
PCE Statistical Data
PCE Eligible kWh - Residential Customers 309,302 Average Annual PCE Payment per Eligible
Customer
$49
PCE Eligible kWh - Community Facility
Customers
0 Average PCE Payment per Eligible kWh $0.01
Total PCE Eligible kWh 309,302 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.27
Average Monthly PCE Eligible kWh per
Residential Customer
271 Last Reported PCE Level (per kWh)$0.02
Average Monthly PCE Eligible kWh per
Community Facility Customer
0 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
0 PCE Eligible kWh vs Total kWh Sold 47.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $49,633
Non-Fuel Expense per kWh Sold $0.08
Total Expense per kWh Sold $0.08
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 468,928 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 0 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)176,217 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 645,145 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 11,544
Total kWh Sold & PH Consumption 656,689
Comments
See Craig For Power Generation
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 118 of 187
Nelson Lagoon PCE
Utility: NELSON LAGOON ELECTRICAL COOP
Reporting Period: 07/01/19..06/30/20
Community Population 32
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 33
Community Facility Customers 6
Other Customers (Non-PCE)23
Fiscal Year PCE Payments $51,353
PCE Statistical Data
PCE Eligible kWh - Residential Customers 100,392 Average Annual PCE Payment per Eligible
Customer
$1,317
PCE Eligible kWh - Community Facility
Customers
23,650 Average PCE Payment per Eligible kWh $0.41
Total PCE Eligible kWh 124,042 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.84
Average Monthly PCE Eligible kWh per
Residential Customer
254 Last Reported PCE Level (per kWh)$0.42
Average Monthly PCE Eligible kWh per
Community Facility Customer
328 Effective Residential Rate (per kWh)$0.42
Average Monthly PCE Eligible Community
Facility kWh per Person
62 PCE Eligible kWh vs Total kWh Sold 49.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 304,645 Fuel Used (Gallons)37,120
Non-Diesel kWh Generated 0 Fuel Cost $117,742
Purchased kWh 0 Average Price of Fuel $3.17
Total Purchased & Generated 304,645 Fuel Cost per kWh sold $0.47
Annual Non-Fuel Expenses $36,568
Non-Fuel Expense per kWh Sold $0.15
Total Expense per kWh Sold $0.61
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 124,578 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
82.5%
Community Facility kWh Sold 26,584 Line Loss (%)12.7%
Other kWh Sold (Non-PCE)100,140 Fuel Efficiency (kWh per Gallon of Diesel)8.21
Total kWh Sold 251,302 PH Consumption as % of Generation 4.8%
Powerhouse (PH) Consumption kWh 14,593
Total kWh Sold & PH Consumption 265,895
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 119 of 187
New Stuyahok PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 496
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 103
Community Facility Customers 9
Other Customers (Non-PCE)39
Fiscal Year PCE Payments $208,335
PCE Statistical Data
PCE Eligible kWh - Residential Customers 470,789 Average Annual PCE Payment per Eligible
Customer
$1,860
PCE Eligible kWh - Community Facility
Customers
113,186 Average PCE Payment per Eligible kWh $0.36
Total PCE Eligible kWh 583,975 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.62
Average Monthly PCE Eligible kWh per
Residential Customer
381 Last Reported PCE Level (per kWh)$0.35
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,048 Effective Residential Rate (per kWh)$0.27
Average Monthly PCE Eligible Community
Facility kWh per Person
19 PCE Eligible kWh vs Total kWh Sold 43.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,864,066 Fuel Used (Gallons)131,421
Non-Diesel kWh Generated 0 Fuel Cost $487,394
Purchased kWh 0 Average Price of Fuel $3.71
Total Purchased & Generated 1,864,066 Fuel Cost per kWh sold $0.36
Annual Non-Fuel Expenses $284,330
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.57
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 556,352 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
72.4%
Community Facility kWh Sold 270,865 Line Loss (%)25.6%
Other kWh Sold (Non-PCE)522,828 Fuel Efficiency (kWh per Gallon of Diesel)14.18
Total kWh Sold 1,350,045 PH Consumption as % of Generation 2.0%
Powerhouse (PH) Consumption kWh 36,376
Total kWh Sold & PH Consumption 1,386,421
Comments
Provides Power To Ekwok Via Intertie
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 120 of 187
Newtok PCE
Utility: UNGUSRAQ POWER COMPANY
Reporting Period: 07/01/19..06/30/20
Community Population 345
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 62
Community Facility Customers 2
Other Customers (Non-PCE)23
Fiscal Year PCE Payments $103,725
PCE Statistical Data
PCE Eligible kWh - Residential Customers 196,170 Average Annual PCE Payment per Eligible
Customer
$1,621
PCE Eligible kWh - Community Facility
Customers
24,107 Average PCE Payment per Eligible kWh $0.47
Total PCE Eligible kWh 220,277 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.80
Average Monthly PCE Eligible kWh per
Residential Customer
264 Last Reported PCE Level (per kWh)$0.47
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,004 Effective Residential Rate (per kWh)$0.33
Average Monthly PCE Eligible Community
Facility kWh per Person
6 PCE Eligible kWh vs Total kWh Sold 65.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)39,190
Non-Diesel kWh Generated 0 Fuel Cost $139,657
Purchased kWh 0 Average Price of Fuel $3.56
Total Purchased & Generated 0 Fuel Cost per kWh sold $0.41
Annual Non-Fuel Expenses $142,627
Non-Fuel Expense per kWh Sold $0.42
Total Expense per kWh Sold $0.83
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 210,610 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 24,107 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)104,315 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 339,032 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 339,032
Comments
kWh Generation & Powerhouse Consumption Data Not Available.
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 121 of 187
Nightmute PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 301
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 50
Community Facility Customers 7
Other Customers (Non-PCE)23
Fiscal Year PCE Payments $83,203
PCE Statistical Data
PCE Eligible kWh - Residential Customers 232,687 Average Annual PCE Payment per Eligible
Customer
$1,460
PCE Eligible kWh - Community Facility
Customers
62,619 Average PCE Payment per Eligible kWh $0.28
Total PCE Eligible kWh 295,306 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.58
Average Monthly PCE Eligible kWh per
Residential Customer
388 Last Reported PCE Level (per kWh)$0.30
Average Monthly PCE Eligible kWh per
Community Facility Customer
745 Effective Residential Rate (per kWh)$0.29
Average Monthly PCE Eligible Community
Facility kWh per Person
17 PCE Eligible kWh vs Total kWh Sold 34.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $179,568
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.21
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 281,164 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 119,961 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)451,493 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 852,618 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 852,618
Comments
Receives Power From Toksook Bay Via Intertie
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 122 of 187
Nikolai PCE
Utility: CITY OF NIKOLAI
Reporting Period: 07/01/19..06/30/20
Community Population 91
Last Reported Month June
No. of Monthly Payments Made 10
Residential Customers 42
Community Facility Customers 6
Other Customers (Non-PCE)15
Fiscal Year PCE Payments $75,454
PCE Statistical Data
PCE Eligible kWh - Residential Customers 104,953 Average Annual PCE Payment per Eligible
Customer
$1,572
PCE Eligible kWh - Community Facility
Customers
41,573 Average PCE Payment per Eligible kWh $0.51
Total PCE Eligible kWh 146,526 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.90
Average Monthly PCE Eligible kWh per
Residential Customer
250 Last Reported PCE Level (per kWh)$0.52
Average Monthly PCE Eligible kWh per
Community Facility Customer
693 Effective Residential Rate (per kWh)$0.38
Average Monthly PCE Eligible Community
Facility kWh per Person
46 PCE Eligible kWh vs Total kWh Sold 40.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 422,258 Fuel Used (Gallons)34,367
Non-Diesel kWh Generated 0 Fuel Cost $169,105
Purchased kWh 0 Average Price of Fuel $4.92
Total Purchased & Generated 422,258 Fuel Cost per kWh sold $0.47
Annual Non-Fuel Expenses $0
Non-Fuel Expense per kWh Sold See Comments
Total Expense per kWh Sold $0.47
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 147,966 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
85.4%
Community Facility kWh Sold 44,100 Line Loss (%)13.3%
Other kWh Sold (Non-PCE)168,526 Fuel Efficiency (kWh per Gallon of Diesel)12.29
Total kWh Sold 360,592 PH Consumption as % of Generation 1.3%
Powerhouse (PH) Consumption kWh 5,498
Total kWh Sold & PH Consumption 366,090
Comments
Non-Fuel Costs Not Reported
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 123 of 187
Nikolski PCE
Utility: UMNAK POWER COMPANY
Reporting Period: 07/01/19..06/30/20
Community Population 18
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 13
Community Facility Customers 5
Other Customers (Non-PCE)8
Fiscal Year PCE Payments $33,752
PCE Statistical Data
PCE Eligible kWh - Residential Customers 45,260 Average Annual PCE Payment per Eligible
Customer
$1,875
PCE Eligible kWh - Community Facility
Customers
15,120 Average PCE Payment per Eligible kWh $0.56
Total PCE Eligible kWh 60,380 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.75
Average Monthly PCE Eligible kWh per
Residential Customer
290 Last Reported PCE Level (per kWh)$0.56
Average Monthly PCE Eligible kWh per
Community Facility Customer
252 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per Person
70 PCE Eligible kWh vs Total kWh Sold 38.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 195,575 Fuel Used (Gallons)17,151
Non-Diesel kWh Generated 0 Fuel Cost $121,477
Purchased kWh 0 Average Price of Fuel $7.08
Total Purchased & Generated 195,575 Fuel Cost per kWh sold $0.78
Annual Non-Fuel Expenses $61,013
Non-Fuel Expense per kWh Sold $0.39
Total Expense per kWh Sold $1.17
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 49,575 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
79.9%
Community Facility kWh Sold 30,121 Line Loss (%)5.9%
Other kWh Sold (Non-PCE)76,544 Fuel Efficiency (kWh per Gallon of Diesel)11.40
Total kWh Sold 156,240 PH Consumption as % of Generation 14.2%
Powerhouse (PH) Consumption kWh 27,848
Total kWh Sold & PH Consumption 184,088
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 124 of 187
Noatak PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 581
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 116
Community Facility Customers 7
Other Customers (Non-PCE)29
Fiscal Year PCE Payments $466,128
PCE Statistical Data
PCE Eligible kWh - Residential Customers 602,972 Average Annual PCE Payment per Eligible
Customer
$3,790
PCE Eligible kWh - Community Facility
Customers
166,966 Average PCE Payment per Eligible kWh $0.61
Total PCE Eligible kWh 769,938 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.94
Average Monthly PCE Eligible kWh per
Residential Customer
433 Last Reported PCE Level (per kWh)$0.66
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,988 Effective Residential Rate (per kWh)$0.28
Average Monthly PCE Eligible Community
Facility kWh per Person
24 PCE Eligible kWh vs Total kWh Sold 45.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,859,086 Fuel Used (Gallons)129,989
Non-Diesel kWh Generated 0 Fuel Cost $932,436
Purchased kWh 0 Average Price of Fuel $7.17
Total Purchased & Generated 1,859,086 Fuel Cost per kWh sold $0.55
Annual Non-Fuel Expenses $355,099
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.76
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 805,071 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
90.7%
Community Facility kWh Sold 275,142 Line Loss (%)6.5%
Other kWh Sold (Non-PCE)605,853 Fuel Efficiency (kWh per Gallon of Diesel)14.30
Total kWh Sold 1,686,066 PH Consumption as % of Generation 2.8%
Powerhouse (PH) Consumption kWh 52,572
Total kWh Sold & PH Consumption 1,738,638
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 125 of 187
Nome PCE
Utility: NOME JOINT UTILITY SYSTEM
Reporting Period: 07/01/19..06/30/20
Community Population 3662
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 1,748
Community Facility Customers 79
Other Customers (Non-PCE)373
Fiscal Year PCE Payments $929,935
PCE Statistical Data
PCE Eligible kWh - Residential Customers 5,583,067 Average Annual PCE Payment per Eligible
Customer
$509
PCE Eligible kWh - Community Facility
Customers
2,137,750 Average PCE Payment per Eligible kWh $0.12
Total PCE Eligible kWh 7,720,817 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.36
Average Monthly PCE Eligible kWh per
Residential Customer
266 Last Reported PCE Level (per kWh)$0.11
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,255 Effective Residential Rate (per kWh)$0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
49 PCE Eligible kWh vs Total kWh Sold 26.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 29,374,743 Fuel Used (Gallons)1,868,237
Non-Diesel kWh Generated 2,186,915 Fuel Cost $4,512,210
Purchased kWh 0 Average Price of Fuel $2.42
Total Purchased & Generated 31,561,658 Fuel Cost per kWh sold $0.16
Annual Non-Fuel Expenses $7,081,890
Non-Fuel Expense per kWh Sold $0.25
Total Expense per kWh Sold $0.40
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 8,723,376 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
91.5%
Community Facility kWh Sold 2,421,905 Line Loss (%)4.6%
Other kWh Sold (Non-PCE)17,717,921 Fuel Efficiency (kWh per Gallon of Diesel)15.72
Total kWh Sold 28,863,202 PH Consumption as % of Generation 4.0%
Powerhouse (PH) Consumption kWh 1,259,194
Total kWh Sold & PH Consumption 30,122,396
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 126 of 187
Noorvik PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 629
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 133
Community Facility Customers 10
Other Customers (Non-PCE)33
Fiscal Year PCE Payments $298,873
PCE Statistical Data
PCE Eligible kWh - Residential Customers 637,121 Average Annual PCE Payment per Eligible
Customer
$2,090
PCE Eligible kWh - Community Facility
Customers
324,743 Average PCE Payment per Eligible kWh $0.31
Total PCE Eligible kWh 961,864 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.58
Average Monthly PCE Eligible kWh per
Residential Customer
399 Last Reported PCE Level (per kWh)$0.31
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,706 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
43 PCE Eligible kWh vs Total kWh Sold 50.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,993,735 Fuel Used (Gallons)143,753
Non-Diesel kWh Generated 11,418 Fuel Cost $493,916
Purchased kWh 0 Average Price of Fuel $3.44
Total Purchased & Generated 2,005,153 Fuel Cost per kWh sold $0.26
Annual Non-Fuel Expenses $399,843
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.47
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 878,975 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
94.7%
Community Facility kWh Sold 426,998 Line Loss (%)3.8%
Other kWh Sold (Non-PCE)592,546 Fuel Efficiency (kWh per Gallon of Diesel)13.87
Total kWh Sold 1,898,519 PH Consumption as % of Generation 1.6%
Powerhouse (PH) Consumption kWh 31,396
Total kWh Sold & PH Consumption 1,929,915
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 127 of 187
Northway; Northway Village PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/19..06/30/20
Community Population 158
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 85
Community Facility Customers 6
Other Customers (Non-PCE)31
Fiscal Year PCE Payments $119,501
PCE Statistical Data
PCE Eligible kWh - Residential Customers 283,385 Average Annual PCE Payment per Eligible
Customer
$1,313
PCE Eligible kWh - Community Facility
Customers
83,778 Average PCE Payment per Eligible kWh $0.33
Total PCE Eligible kWh 367,163 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.57
Average Monthly PCE Eligible kWh per
Residential Customer
278 Last Reported PCE Level (per kWh)$0.27
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,164 Effective Residential Rate (per kWh)$0.30
Average Monthly PCE Eligible Community
Facility kWh per Person
44 PCE Eligible kWh vs Total kWh Sold 36.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,097,600 Fuel Used (Gallons)85,939
Non-Diesel kWh Generated 0 Fuel Cost $222,592
Purchased kWh 0 Average Price of Fuel $2.59
Total Purchased & Generated 1,097,600 Fuel Cost per kWh sold $0.22
Annual Non-Fuel Expenses $162,632
Non-Fuel Expense per kWh Sold $0.16
Total Expense per kWh Sold $0.39
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 329,127 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
91.1%
Community Facility kWh Sold 83,924 Line Loss (%)7.7%
Other kWh Sold (Non-PCE)587,308 Fuel Efficiency (kWh per Gallon of Diesel)12.77
Total kWh Sold 1,000,359 PH Consumption as % of Generation 1.2%
Powerhouse (PH) Consumption kWh 13,248
Total kWh Sold & PH Consumption 1,013,607
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 128 of 187
Nuiqsut PCE
Utility: NORTH SLOPE BOROUGH
Reporting Period: 07/01/19..06/30/20
Community Population 481
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 111
Community Facility Customers 3
Other Customers (Non-PCE)77
Fiscal Year PCE Payments $7,781
PCE Statistical Data
PCE Eligible kWh - Residential Customers 480,374 Average Annual PCE Payment per Eligible
Customer
$68
PCE Eligible kWh - Community Facility
Customers
93,420 Average PCE Payment per Eligible kWh $0.01
Total PCE Eligible kWh 573,794 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.08
Average Monthly PCE Eligible kWh per
Residential Customer
361 Last Reported PCE Level (per kWh)$0.00
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,595 Effective Residential Rate (per kWh)$0.08
Average Monthly PCE Eligible Community
Facility kWh per Person
16 PCE Eligible kWh vs Total kWh Sold 9.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,900,591 Fuel Used (Gallons)180,124
Non-Diesel kWh Generated 5,230,837 Fuel Cost $773,353
Purchased kWh 0 Average Price of Fuel $4.29
Total Purchased & Generated 7,131,428 Fuel Cost per kWh sold $0.13
Annual Non-Fuel Expenses $1,083,928
Non-Fuel Expense per kWh Sold $0.18
Total Expense per kWh Sold $0.31
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 970,546 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
84.0%
Community Facility kWh Sold 93,420 Line Loss (%)10.7%
Other kWh Sold (Non-PCE)4,928,204 Fuel Efficiency (kWh per Gallon of Diesel)10.55
Total kWh Sold 5,992,170 PH Consumption as % of Generation 5.3%
Powerhouse (PH) Consumption kWh 377,629
Total kWh Sold & PH Consumption 6,369,799
Comments
kWh's Gen'd & Pwrhse Consumption = 11 Months. Residential PCE Level = Zero
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 129 of 187
Nulato PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 206
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 113
Community Facility Customers 15
Other Customers (Non-PCE)14
Fiscal Year PCE Payments $179,652
PCE Statistical Data
PCE Eligible kWh - Residential Customers 393,033 Average Annual PCE Payment per Eligible
Customer
$1,404
PCE Eligible kWh - Community Facility
Customers
170,657 Average PCE Payment per Eligible kWh $0.32
Total PCE Eligible kWh 563,690 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.57
Average Monthly PCE Eligible kWh per
Residential Customer
290 Last Reported PCE Level (per kWh)$0.30
Average Monthly PCE Eligible kWh per
Community Facility Customer
948 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
69 PCE Eligible kWh vs Total kWh Sold 59.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,022,711 Fuel Used (Gallons)71,075
Non-Diesel kWh Generated 0 Fuel Cost $211,683
Purchased kWh 0 Average Price of Fuel $2.98
Total Purchased & Generated 1,022,711 Fuel Cost per kWh sold $0.22
Annual Non-Fuel Expenses $199,438
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.43
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 457,727 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
92.6%
Community Facility kWh Sold 262,919 Line Loss (%)5.7%
Other kWh Sold (Non-PCE)226,316 Fuel Efficiency (kWh per Gallon of Diesel)14.39
Total kWh Sold 946,962 PH Consumption as % of Generation 1.7%
Powerhouse (PH) Consumption kWh 17,197
Total kWh Sold & PH Consumption 964,159
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 130 of 187
Nunam Iqua PCE
Utility: NUNAM IQUA ELECTRIC COMPANY
Reporting Period: 07/01/19..06/30/20
Community Population 225
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 46
Community Facility Customers 6
Other Customers (Non-PCE)15
Fiscal Year PCE Payments $80,232
PCE Statistical Data
PCE Eligible kWh - Residential Customers 200,973 Average Annual PCE Payment per Eligible
Customer
$1,543
PCE Eligible kWh - Community Facility
Customers
148,238 Average PCE Payment per Eligible kWh $0.23
Total PCE Eligible kWh 349,211 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.47
Average Monthly PCE Eligible kWh per
Residential Customer
364 Last Reported PCE Level (per kWh)$0.23
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,059 Effective Residential Rate (per kWh)$0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
55 PCE Eligible kWh vs Total kWh Sold 44.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 851,564 Fuel Used (Gallons)65,137
Non-Diesel kWh Generated 0 Fuel Cost $198,477
Purchased kWh 0 Average Price of Fuel $3.05
Total Purchased & Generated 851,564 Fuel Cost per kWh sold $0.25
Annual Non-Fuel Expenses $125,926
Non-Fuel Expense per kWh Sold $0.16
Total Expense per kWh Sold $0.41
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 238,116 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
91.9%
Community Facility kWh Sold 154,938 Line Loss (%)3.8%
Other kWh Sold (Non-PCE)389,557 Fuel Efficiency (kWh per Gallon of Diesel)13.07
Total kWh Sold 782,611 PH Consumption as % of Generation 4.3%
Powerhouse (PH) Consumption kWh 36,874
Total kWh Sold & PH Consumption 819,485
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 131 of 187
Nunapitchuk PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 591
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 124
Community Facility Customers 11
Other Customers (Non-PCE)29
Fiscal Year PCE Payments $182,812
PCE Statistical Data
PCE Eligible kWh - Residential Customers 539,054 Average Annual PCE Payment per Eligible
Customer
$1,354
PCE Eligible kWh - Community Facility
Customers
113,220 Average PCE Payment per Eligible kWh $0.28
Total PCE Eligible kWh 652,274 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.55
Average Monthly PCE Eligible kWh per
Residential Customer
362 Last Reported PCE Level (per kWh)$0.27
Average Monthly PCE Eligible kWh per
Community Facility Customer
858 Effective Residential Rate (per kWh)$0.28
Average Monthly PCE Eligible Community
Facility kWh per Person
16 PCE Eligible kWh vs Total kWh Sold 53.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $259,386
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.21
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 611,322 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 164,512 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)455,773 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 1,231,607 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 1,231,607
Comments
Receives Power From Kasigluk Via Intertie
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 132 of 187
Old Harbor PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 224
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 90
Community Facility Customers 12
Other Customers (Non-PCE)24
Fiscal Year PCE Payments $147,376
PCE Statistical Data
PCE Eligible kWh - Residential Customers 299,451 Average Annual PCE Payment per Eligible
Customer
$1,445
PCE Eligible kWh - Community Facility
Customers
162,161 Average PCE Payment per Eligible kWh $0.32
Total PCE Eligible kWh 461,612 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.53
Average Monthly PCE Eligible kWh per
Residential Customer
277 Last Reported PCE Level (per kWh)$0.27
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,126 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
60 PCE Eligible kWh vs Total kWh Sold 64.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 787,052 Fuel Used (Gallons)49,986
Non-Diesel kWh Generated 0 Fuel Cost $152,746
Purchased kWh 0 Average Price of Fuel $3.06
Total Purchased & Generated 787,052 Fuel Cost per kWh sold $0.21
Annual Non-Fuel Expenses $150,993
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.42
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 356,767 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
91.1%
Community Facility kWh Sold 251,247 Line Loss (%)4.9%
Other kWh Sold (Non-PCE)108,924 Fuel Efficiency (kWh per Gallon of Diesel)15.75
Total kWh Sold 716,938 PH Consumption as % of Generation 4.0%
Powerhouse (PH) Consumption kWh 31,421
Total kWh Sold & PH Consumption 748,359
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 133 of 187
Ouzinkie PCE
Utility: CITY OF OUZINKIE
Reporting Period: 07/01/19..06/30/20
Community Population 154
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 73
Community Facility Customers 16
Other Customers (Non-PCE)22
Fiscal Year PCE Payments $38,197
PCE Statistical Data
PCE Eligible kWh - Residential Customers 217,313 Average Annual PCE Payment per Eligible
Customer
$429
PCE Eligible kWh - Community Facility
Customers
99,757 Average PCE Payment per Eligible kWh $0.12
Total PCE Eligible kWh 317,070 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.43
Average Monthly PCE Eligible kWh per
Residential Customer
248 Last Reported PCE Level (per kWh)$0.11
Average Monthly PCE Eligible kWh per
Community Facility Customer
520 Effective Residential Rate (per kWh)$0.32
Average Monthly PCE Eligible Community
Facility kWh per Person
54 PCE Eligible kWh vs Total kWh Sold 53.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 479,068 Fuel Used (Gallons)39,025
Non-Diesel kWh Generated 195,000 Fuel Cost $116,961
Purchased kWh 0 Average Price of Fuel $3.00
Total Purchased & Generated 674,068 Fuel Cost per kWh sold $0.20
Annual Non-Fuel Expenses $142,739
Non-Fuel Expense per kWh Sold $0.24
Total Expense per kWh Sold $0.44
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 242,451 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
87.3%
Community Facility kWh Sold 117,523 Line Loss (%)7.8%
Other kWh Sold (Non-PCE)228,430 Fuel Efficiency (kWh per Gallon of Diesel)12.28
Total kWh Sold 588,404 PH Consumption as % of Generation 4.9%
Powerhouse (PH) Consumption kWh 33,030
Total kWh Sold & PH Consumption 621,434
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 134 of 187
Pedro Bay PCE
Utility: PEDRO BAY VILLAGE COUNCIL
Reporting Period: 07/01/19..06/30/20
Community Population 33
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 42
Community Facility Customers 4
Other Customers (Non-PCE)16
Fiscal Year PCE Payments $19,602
PCE Statistical Data
PCE Eligible kWh - Residential Customers 32,346 Average Annual PCE Payment per Eligible
Customer
$426
PCE Eligible kWh - Community Facility
Customers
19,946 Average PCE Payment per Eligible kWh $0.37
Total PCE Eligible kWh 52,292 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.81
Average Monthly PCE Eligible kWh per
Residential Customer
64 Last Reported PCE Level (per kWh)$0.35
Average Monthly PCE Eligible kWh per
Community Facility Customer
416 Effective Residential Rate (per kWh)$0.46
Average Monthly PCE Eligible Community
Facility kWh per Person
50 PCE Eligible kWh vs Total kWh Sold 33.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 196,166 Fuel Used (Gallons)19,338
Non-Diesel kWh Generated 0 Fuel Cost $76,938
Purchased kWh 0 Average Price of Fuel $3.98
Total Purchased & Generated 196,166 Fuel Cost per kWh sold $0.49
Annual Non-Fuel Expenses $38,902
Non-Fuel Expense per kWh Sold $0.25
Total Expense per kWh Sold $0.74
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 51,549 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
80.3%
Community Facility kWh Sold 20,599 Line Loss (%)13.4%
Other kWh Sold (Non-PCE)85,449 Fuel Efficiency (kWh per Gallon of Diesel)10.14
Total kWh Sold 157,597 PH Consumption as % of Generation 6.3%
Powerhouse (PH) Consumption kWh 12,276
Total kWh Sold & PH Consumption 169,873
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 135 of 187
Perryville PCE
Utility: NATIVE VILLAGE OF PERRYVILLE
Reporting Period: 07/01/19..06/30/20
Community Population 98
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 47
Community Facility Customers 0
Other Customers (Non-PCE)21
Fiscal Year PCE Payments $24,563
PCE Statistical Data
PCE Eligible kWh - Residential Customers 109,591 Average Annual PCE Payment per Eligible
Customer
$523
PCE Eligible kWh - Community Facility
Customers
0 Average PCE Payment per Eligible kWh $0.22
Total PCE Eligible kWh 109,591 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.95
Average Monthly PCE Eligible kWh per
Residential Customer
194 Last Reported PCE Level (per kWh)$0.23
Average Monthly PCE Eligible kWh per
Community Facility Customer
0 Effective Residential Rate (per kWh)$0.72
Average Monthly PCE Eligible Community
Facility kWh per Person
0 PCE Eligible kWh vs Total kWh Sold 25.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 417,888 Fuel Used (Gallons)38,415
Non-Diesel kWh Generated 20,361 Fuel Cost $126,165
Purchased kWh 0 Average Price of Fuel $3.28
Total Purchased & Generated 438,249 Fuel Cost per kWh sold $0.30
Annual Non-Fuel Expenses $105,467
Non-Fuel Expense per kWh Sold $0.25
Total Expense per kWh Sold $0.55
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 112,089 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
96.7%
Community Facility kWh Sold 0 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)311,798 Fuel Efficiency (kWh per Gallon of Diesel)10.88
Total kWh Sold 423,887 PH Consumption as % of Generation 4.5%
Powerhouse (PH) Consumption kWh 19,859
Total kWh Sold & PH Consumption 443,746
Comments
kWh's Generated & Powerhouse Consumption = 11 Months
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 136 of 187
Pilot Point PCE
Utility: PILOT POINT ELECTRIC UTILITY
Reporting Period: 07/01/19..06/30/20
Community Population 83
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 40
Community Facility Customers 10
Other Customers (Non-PCE)23
Fiscal Year PCE Payments $69,095
PCE Statistical Data
PCE Eligible kWh - Residential Customers 119,758 Average Annual PCE Payment per Eligible
Customer
$1,382
PCE Eligible kWh - Community Facility
Customers
49,178 Average PCE Payment per Eligible kWh $0.41
Total PCE Eligible kWh 168,936 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.60
Average Monthly PCE Eligible kWh per
Residential Customer
249 Last Reported PCE Level (per kWh)$0.41
Average Monthly PCE Eligible kWh per
Community Facility Customer
410 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per Person
49 PCE Eligible kWh vs Total kWh Sold 42.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 340,219 Fuel Used (Gallons)48,094
Non-Diesel kWh Generated 0 Fuel Cost $139,811
Purchased kWh 0 Average Price of Fuel $2.91
Total Purchased & Generated 340,219 Fuel Cost per kWh sold $0.35
Annual Non-Fuel Expenses $38,560
Non-Fuel Expense per kWh Sold $0.10
Total Expense per kWh Sold $0.45
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 144,385 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 50,153 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)200,860 Fuel Efficiency (kWh per Gallon of Diesel)7.07
Total kWh Sold 395,398 PH Consumption as % of Generation 4.9%
Powerhouse (PH) Consumption kWh 16,545
Total kWh Sold & PH Consumption 411,943
Comments
kWh's Generated & Powerhouse Consumption = 8 Months.
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 137 of 187
Pilot Station PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 640
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 135
Community Facility Customers 13
Other Customers (Non-PCE)24
Fiscal Year PCE Payments $269,064
PCE Statistical Data
PCE Eligible kWh - Residential Customers 573,781 Average Annual PCE Payment per Eligible
Customer
$1,818
PCE Eligible kWh - Community Facility
Customers
288,291 Average PCE Payment per Eligible kWh $0.31
Total PCE Eligible kWh 862,072 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.56
Average Monthly PCE Eligible kWh per
Residential Customer
354 Last Reported PCE Level (per kWh)$0.30
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,848 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
38 PCE Eligible kWh vs Total kWh Sold 48.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,869,520 Fuel Used (Gallons)133,971
Non-Diesel kWh Generated 0 Fuel Cost $392,686
Purchased kWh 0 Average Price of Fuel $2.93
Total Purchased & Generated 1,869,520 Fuel Cost per kWh sold $0.22
Annual Non-Fuel Expenses $375,549
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.43
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 680,878 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
95.4%
Community Facility kWh Sold 324,976 Line Loss (%)2.8%
Other kWh Sold (Non-PCE)777,312 Fuel Efficiency (kWh per Gallon of Diesel)13.95
Total kWh Sold 1,783,166 PH Consumption as % of Generation 1.9%
Powerhouse (PH) Consumption kWh 34,687
Total kWh Sold & PH Consumption 1,817,853
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 138 of 187
Pitkas Point PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 126
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 31
Community Facility Customers 5
Other Customers (Non-PCE)3
Fiscal Year PCE Payments $50,473
PCE Statistical Data
PCE Eligible kWh - Residential Customers 126,483 Average Annual PCE Payment per Eligible
Customer
$1,402
PCE Eligible kWh - Community Facility
Customers
97,326 Average PCE Payment per Eligible kWh $0.23
Total PCE Eligible kWh 223,809 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.38
Average Monthly PCE Eligible kWh per
Residential Customer
340 Last Reported PCE Level (per kWh)$0.12
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,622 Effective Residential Rate (per kWh)$0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
64 PCE Eligible kWh vs Total kWh Sold 75.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $62,249
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.21
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 143,995 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 151,575 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)0 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 295,570 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 295,570
Comments
Receives Power From St. Mary's/Andreafsky Via Intertie
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 139 of 187
Point Hope PCE
Utility: NORTH SLOPE BOROUGH
Reporting Period: 07/01/19..06/30/20
Community Population 749
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 193
Community Facility Customers 2
Other Customers (Non-PCE)81
Fiscal Year PCE Payments $3,101
PCE Statistical Data
PCE Eligible kWh - Residential Customers 601,628 Average Annual PCE Payment per Eligible
Customer
$16
PCE Eligible kWh - Community Facility
Customers
44,127 Average PCE Payment per Eligible kWh $0.00
Total PCE Eligible kWh 645,755 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.15
Average Monthly PCE Eligible kWh per
Residential Customer
260 Last Reported PCE Level (per kWh)$0.00
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,839 Effective Residential Rate (per kWh)$0.15
Average Monthly PCE Eligible Community
Facility kWh per Person
5 PCE Eligible kWh vs Total kWh Sold 11.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 4,053,901 Fuel Used (Gallons)539,934
Non-Diesel kWh Generated 0 Fuel Cost $1,779,660
Purchased kWh 0 Average Price of Fuel $3.30
Total Purchased & Generated 4,053,901 Fuel Cost per kWh sold $0.31
Annual Non-Fuel Expenses $1,325,830
Non-Fuel Expense per kWh Sold $0.23
Total Expense per kWh Sold $0.55
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,789,849 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 44,127 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)3,840,673 Fuel Efficiency (kWh per Gallon of Diesel)7.51
Total kWh Sold 5,674,649 PH Consumption as % of Generation 7.3%
Powerhouse (PH) Consumption kWh 294,443
Total kWh Sold & PH Consumption 5,969,092
Comments
kWh's Generated = 8 Months. Residential PCE Level = $0.00 Per Eligible kWh.
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 140 of 187
Point Lay PCE
Utility: NORTH SLOPE BOROUGH
Reporting Period: 07/01/19..06/30/20
Community Population 287
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 64
Community Facility Customers 1
Other Customers (Non-PCE)44
Fiscal Year PCE Payments $2,564
PCE Statistical Data
PCE Eligible kWh - Residential Customers 151,394 Average Annual PCE Payment per Eligible
Customer
$39
PCE Eligible kWh - Community Facility
Customers
31,930 Average PCE Payment per Eligible kWh $0.01
Total PCE Eligible kWh 183,324 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.23
Average Monthly PCE Eligible kWh per
Residential Customer
197 Last Reported PCE Level (per kWh)$0.00
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,661 Effective Residential Rate (per kWh)$0.23
Average Monthly PCE Eligible Community
Facility kWh per Person
9 PCE Eligible kWh vs Total kWh Sold 5.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 3,709,535 Fuel Used (Gallons)270,434
Non-Diesel kWh Generated 0 Fuel Cost $942,714
Purchased kWh 0 Average Price of Fuel $3.49
Total Purchased & Generated 3,709,535 Fuel Cost per kWh sold $0.30
Annual Non-Fuel Expenses $1,031,494
Non-Fuel Expense per kWh Sold $0.33
Total Expense per kWh Sold $0.63
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 640,144 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
85.1%
Community Facility kWh Sold 31,930 Line Loss (%)14.3%
Other kWh Sold (Non-PCE)2,486,313 Fuel Efficiency (kWh per Gallon of Diesel)13.72
Total kWh Sold 3,158,387 PH Consumption as % of Generation 0.6%
Powerhouse (PH) Consumption kWh 22,521
Total kWh Sold & PH Consumption 3,180,908
Comments
Residential PCE Level = $0.00 Per Eligible kWh
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 141 of 187
Port Alsworth PCE
Utility: TANALIAN ELECTRIC COOPERATIVE
Reporting Period: 07/01/19..06/30/20
Community Population 227
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 80
Community Facility Customers 0
Other Customers (Non-PCE)72
Fiscal Year PCE Payments $115,570
PCE Statistical Data
PCE Eligible kWh - Residential Customers 269,323 Average Annual PCE Payment per Eligible
Customer
$1,445
PCE Eligible kWh - Community Facility
Customers
0 Average PCE Payment per Eligible kWh $0.43
Total PCE Eligible kWh 269,323 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.65
Average Monthly PCE Eligible kWh per
Residential Customer
281 Last Reported PCE Level (per kWh)$0.40
Average Monthly PCE Eligible kWh per
Community Facility Customer
0 Effective Residential Rate (per kWh)$0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
0 PCE Eligible kWh vs Total kWh Sold 32.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 907,497 Fuel Used (Gallons)68,069
Non-Diesel kWh Generated 0 Fuel Cost $262,233
Purchased kWh 0 Average Price of Fuel $3.85
Total Purchased & Generated 907,497 Fuel Cost per kWh sold $0.32
Annual Non-Fuel Expenses $0
Non-Fuel Expense per kWh Sold See Comments
Total Expense per kWh Sold $0.32
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 333,021 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
91.0%
Community Facility kWh Sold 0 Line Loss (%)6.7%
Other kWh Sold (Non-PCE)493,159 Fuel Efficiency (kWh per Gallon of Diesel)13.33
Total kWh Sold 826,180 PH Consumption as % of Generation 2.3%
Powerhouse (PH) Consumption kWh 20,680
Total kWh Sold & PH Consumption 846,860
Comments
Non-Fuel Costs Not Reported
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 142 of 187
Port Heiden PCE
Utility: PORT HEIDEN UTILITIES
Reporting Period: 07/01/19..06/30/20
Community Population 119
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 48
Community Facility Customers 8
Other Customers (Non-PCE)33
Fiscal Year PCE Payments $71,828
PCE Statistical Data
PCE Eligible kWh - Residential Customers 145,783 Average Annual PCE Payment per Eligible
Customer
$1,283
PCE Eligible kWh - Community Facility
Customers
48,594 Average PCE Payment per Eligible kWh $0.37
Total PCE Eligible kWh 194,377 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.65
Average Monthly PCE Eligible kWh per
Residential Customer
253 Last Reported PCE Level (per kWh)$0.36
Average Monthly PCE Eligible kWh per
Community Facility Customer
506 Effective Residential Rate (per kWh)$0.29
Average Monthly PCE Eligible Community
Facility kWh per Person
34 PCE Eligible kWh vs Total kWh Sold 37.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 601,981 Fuel Used (Gallons)50,860
Non-Diesel kWh Generated 0 Fuel Cost $159,403
Purchased kWh 0 Average Price of Fuel $3.13
Total Purchased & Generated 601,981 Fuel Cost per kWh sold $0.31
Annual Non-Fuel Expenses $28,391
Non-Fuel Expense per kWh Sold $0.06
Total Expense per kWh Sold $0.36
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 182,586 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
85.6%
Community Facility kWh Sold 51,042 Line Loss (%)9.8%
Other kWh Sold (Non-PCE)281,427 Fuel Efficiency (kWh per Gallon of Diesel)11.84
Total kWh Sold 515,055 PH Consumption as % of Generation 4.6%
Powerhouse (PH) Consumption kWh 27,789
Total kWh Sold & PH Consumption 542,844
Comments
Fuel Used & Fuel Costs = 11 Months. Non-Fuel Costs = 8 Months.
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 143 of 187
Quinhagak PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 747
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 188
Community Facility Customers 16
Other Customers (Non-PCE)21
Fiscal Year PCE Payments $274,241
PCE Statistical Data
PCE Eligible kWh - Residential Customers 837,582 Average Annual PCE Payment per Eligible
Customer
$1,344
PCE Eligible kWh - Community Facility
Customers
286,673 Average PCE Payment per Eligible kWh $0.24
Total PCE Eligible kWh 1,124,255 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.52
Average Monthly PCE Eligible kWh per
Residential Customer
371 Last Reported PCE Level (per kWh)$0.24
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,493 Effective Residential Rate (per kWh)$0.29
Average Monthly PCE Eligible Community
Facility kWh per Person
32 PCE Eligible kWh vs Total kWh Sold 52.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,796,505 Fuel Used (Gallons)128,075
Non-Diesel kWh Generated 505,401 Fuel Cost $379,204
Purchased kWh 0 Average Price of Fuel $2.96
Total Purchased & Generated 2,301,906 Fuel Cost per kWh sold $0.18
Annual Non-Fuel Expenses $447,748
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.39
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,069,176 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
92.4%
Community Facility kWh Sold 425,752 Line Loss (%)5.0%
Other kWh Sold (Non-PCE)631,053 Fuel Efficiency (kWh per Gallon of Diesel)14.03
Total kWh Sold 2,125,981 PH Consumption as % of Generation 2.6%
Powerhouse (PH) Consumption kWh 60,760
Total kWh Sold & PH Consumption 2,186,741
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 144 of 187
Rampart PCE
Utility: RAMPART VILLAGE COUNCIL
Reporting Period: 07/01/19..06/30/20
Community Population 86
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 43
Community Facility Customers 8
Other Customers (Non-PCE)6
Fiscal Year PCE Payments $66,062
PCE Statistical Data
PCE Eligible kWh - Residential Customers 60,571 Average Annual PCE Payment per Eligible
Customer
$1,295
PCE Eligible kWh - Community Facility
Customers
64,822 Average PCE Payment per Eligible kWh $0.53
Total PCE Eligible kWh 125,393 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.84
Average Monthly PCE Eligible kWh per
Residential Customer
117 Last Reported PCE Level (per kWh)$0.53
Average Monthly PCE Eligible kWh per
Community Facility Customer
675 Effective Residential Rate (per kWh)$0.31
Average Monthly PCE Eligible Community
Facility kWh per Person
63 PCE Eligible kWh vs Total kWh Sold 67.3%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 226,630 Fuel Used (Gallons)23,963
Non-Diesel kWh Generated 0 Fuel Cost $89,085
Purchased kWh 0 Average Price of Fuel $3.72
Total Purchased & Generated 226,630 Fuel Cost per kWh sold $0.48
Annual Non-Fuel Expenses $28,491
Non-Fuel Expense per kWh Sold $0.15
Total Expense per kWh Sold $0.63
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 67,159 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
82.2%
Community Facility kWh Sold 83,970 Line Loss (%)5.6%
Other kWh Sold (Non-PCE)35,073 Fuel Efficiency (kWh per Gallon of Diesel)9.46
Total kWh Sold 186,202 PH Consumption as % of Generation 12.3%
Powerhouse (PH) Consumption kWh 27,764
Total kWh Sold & PH Consumption 213,966
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 145 of 187
Red Devil PCE
Utility: MIDDLE KUSKOKWIM ELECTRIC COOPERATIVE INC
Reporting Period: 07/01/19..06/30/20
Community Population 16
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 10
Community Facility Customers 0
Other Customers (Non-PCE)7
Fiscal Year PCE Payments $23,628
PCE Statistical Data
PCE Eligible kWh - Residential Customers 30,995 Average Annual PCE Payment per Eligible
Customer
$2,363
PCE Eligible kWh - Community Facility
Customers
0 Average PCE Payment per Eligible kWh $0.76
Total PCE Eligible kWh 30,995 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.29
Average Monthly PCE Eligible kWh per
Residential Customer
258 Last Reported PCE Level (per kWh)$0.77
Average Monthly PCE Eligible kWh per
Community Facility Customer
0 Effective Residential Rate (per kWh)$0.52
Average Monthly PCE Eligible Community
Facility kWh per Person
0 PCE Eligible kWh vs Total kWh Sold 57.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 61,563 Fuel Used (Gallons)9,410
Non-Diesel kWh Generated 0 Fuel Cost $30,512
Purchased kWh 0 Average Price of Fuel $3.24
Total Purchased & Generated 61,563 Fuel Cost per kWh sold $0.57
Annual Non-Fuel Expenses $154,474
Non-Fuel Expense per kWh Sold $2.88
Total Expense per kWh Sold $3.45
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 34,136 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
87.0%
Community Facility kWh Sold 0 Line Loss (%)10.2%
Other kWh Sold (Non-PCE)19,420 Fuel Efficiency (kWh per Gallon of Diesel)6.54
Total kWh Sold 53,556 PH Consumption as % of Generation 2.8%
Powerhouse (PH) Consumption kWh 1,707
Total kWh Sold & PH Consumption 55,263
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 146 of 187
Ruby PCE
Utility: CITY OF RUBY
Reporting Period: 07/01/19..06/30/20
Community Population 168
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 109
Community Facility Customers 16
Other Customers (Non-PCE)27
Fiscal Year PCE Payments $127,974
PCE Statistical Data
PCE Eligible kWh - Residential Customers 212,877 Average Annual PCE Payment per Eligible
Customer
$1,024
PCE Eligible kWh - Community Facility
Customers
103,256 Average PCE Payment per Eligible kWh $0.40
Total PCE Eligible kWh 316,133 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.75
Average Monthly PCE Eligible kWh per
Residential Customer
163 Last Reported PCE Level (per kWh)$0.43
Average Monthly PCE Eligible kWh per
Community Facility Customer
538 Effective Residential Rate (per kWh)$0.32
Average Monthly PCE Eligible Community
Facility kWh per Person
51 PCE Eligible kWh vs Total kWh Sold 49.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 273,645 Fuel Used (Gallons)52,147
Non-Diesel kWh Generated 0 Fuel Cost $236,599
Purchased kWh 0 Average Price of Fuel $4.54
Total Purchased & Generated 273,645 Fuel Cost per kWh sold $0.37
Annual Non-Fuel Expenses $181,204
Non-Fuel Expense per kWh Sold $0.29
Total Expense per kWh Sold $0.66
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 238,533 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 107,615 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)286,965 Fuel Efficiency (kWh per Gallon of Diesel)5.25
Total kWh Sold 633,113 PH Consumption as % of Generation 3.5%
Powerhouse (PH) Consumption kWh 9,698
Total kWh Sold & PH Consumption 642,811
Comments
Unable To Verify Plant Meter Readings As Reported. Non-Fuel Costs = 10 Months.
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 147 of 187
Russian Mission PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 340
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 79
Community Facility Customers 7
Other Customers (Non-PCE)15
Fiscal Year PCE Payments $123,531
PCE Statistical Data
PCE Eligible kWh - Residential Customers 351,322 Average Annual PCE Payment per Eligible
Customer
$1,436
PCE Eligible kWh - Community Facility
Customers
60,662 Average PCE Payment per Eligible kWh $0.30
Total PCE Eligible kWh 411,984 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.55
Average Monthly PCE Eligible kWh per
Residential Customer
371 Last Reported PCE Level (per kWh)$0.29
Average Monthly PCE Eligible kWh per
Community Facility Customer
722 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
15 PCE Eligible kWh vs Total kWh Sold 46.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 947,065 Fuel Used (Gallons)70,308
Non-Diesel kWh Generated 0 Fuel Cost $201,995
Purchased kWh 0 Average Price of Fuel $2.87
Total Purchased & Generated 947,065 Fuel Cost per kWh sold $0.23
Annual Non-Fuel Expenses $187,646
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.44
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 405,338 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
94.1%
Community Facility kWh Sold 100,934 Line Loss (%)3.9%
Other kWh Sold (Non-PCE)384,700 Fuel Efficiency (kWh per Gallon of Diesel)13.47
Total kWh Sold 890,972 PH Consumption as % of Generation 2.1%
Powerhouse (PH) Consumption kWh 19,460
Total kWh Sold & PH Consumption 910,432
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 148 of 187
Sand Point PCE
Utility: TDX CORPORATION
Reporting Period: 07/01/19..06/30/20
Community Population 911
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 255
Community Facility Customers 32
Other Customers (Non-PCE)101
Fiscal Year PCE Payments $510,271
PCE Statistical Data
PCE Eligible kWh - Residential Customers 939,206 Average Annual PCE Payment per Eligible
Customer
$1,778
PCE Eligible kWh - Community Facility
Customers
628,357 Average PCE Payment per Eligible kWh $0.33
Total PCE Eligible kWh 1,567,563 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.55
Average Monthly PCE Eligible kWh per
Residential Customer
307 Last Reported PCE Level (per kWh)$0.31
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,636 Effective Residential Rate (per kWh)$0.23
Average Monthly PCE Eligible Community
Facility kWh per Person
57 PCE Eligible kWh vs Total kWh Sold 46.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 3,103,225 Fuel Used (Gallons)224,294
Non-Diesel kWh Generated 0 Fuel Cost $695,707
Purchased kWh 593,846 Average Price of Fuel $3.10
Total Purchased & Generated 3,697,071 Fuel Cost per kWh sold $0.21
Annual Non-Fuel Expenses $0
Non-Fuel Expense per kWh Sold See Comments
Total Expense per kWh Sold $0.21
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,232,318 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
90.9%
Community Facility kWh Sold 774,655 Line Loss (%)6.6%
Other kWh Sold (Non-PCE)1,354,978 Fuel Efficiency (kWh per Gallon of Diesel)13.84
Total kWh Sold 3,361,951 PH Consumption as % of Generation 2.5%
Powerhouse (PH) Consumption kWh 91,600
Total kWh Sold & PH Consumption 3,453,551
Comments
Non-Fuel Costs Not Reported.
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 149 of 187
Savoonga PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 751
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 162
Community Facility Customers 9
Other Customers (Non-PCE)47
Fiscal Year PCE Payments $275,123
PCE Statistical Data
PCE Eligible kWh - Residential Customers 716,468 Average Annual PCE Payment per Eligible
Customer
$1,609
PCE Eligible kWh - Community Facility
Customers
223,619 Average PCE Payment per Eligible kWh $0.29
Total PCE Eligible kWh 940,087 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.56
Average Monthly PCE Eligible kWh per
Residential Customer
369 Last Reported PCE Level (per kWh)$0.29
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,071 Effective Residential Rate (per kWh)$0.27
Average Monthly PCE Eligible Community
Facility kWh per Person
25 PCE Eligible kWh vs Total kWh Sold 42.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,235,694 Fuel Used (Gallons)165,802
Non-Diesel kWh Generated 80,989 Fuel Cost $531,400
Purchased kWh 0 Average Price of Fuel $3.21
Total Purchased & Generated 2,316,683 Fuel Cost per kWh sold $0.24
Annual Non-Fuel Expenses $470,215
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.45
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 977,036 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
96.4%
Community Facility kWh Sold 633,791 Line Loss (%)2.0%
Other kWh Sold (Non-PCE)621,829 Fuel Efficiency (kWh per Gallon of Diesel)13.48
Total kWh Sold 2,232,656 PH Consumption as % of Generation 1.6%
Powerhouse (PH) Consumption kWh 37,088
Total kWh Sold & PH Consumption 2,269,744
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 150 of 187
Scammon Bay PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 598
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 122
Community Facility Customers 8
Other Customers (Non-PCE)40
Fiscal Year PCE Payments $224,639
PCE Statistical Data
PCE Eligible kWh - Residential Customers 523,809 Average Annual PCE Payment per Eligible
Customer
$1,728
PCE Eligible kWh - Community Facility
Customers
179,186 Average PCE Payment per Eligible kWh $0.32
Total PCE Eligible kWh 702,995 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.57
Average Monthly PCE Eligible kWh per
Residential Customer
358 Last Reported PCE Level (per kWh)$0.31
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,867 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
25 PCE Eligible kWh vs Total kWh Sold 45.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,677,422 Fuel Used (Gallons)122,918
Non-Diesel kWh Generated 0 Fuel Cost $379,960
Purchased kWh 0 Average Price of Fuel $3.09
Total Purchased & Generated 1,677,422 Fuel Cost per kWh sold $0.24
Annual Non-Fuel Expenses $328,066
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.45
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 620,491 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
92.9%
Community Facility kWh Sold 278,480 Line Loss (%)5.4%
Other kWh Sold (Non-PCE)658,738 Fuel Efficiency (kWh per Gallon of Diesel)13.65
Total kWh Sold 1,557,709 PH Consumption as % of Generation 1.7%
Powerhouse (PH) Consumption kWh 28,633
Total kWh Sold & PH Consumption 1,586,342
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 151 of 187
Selawik PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 845
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 171
Community Facility Customers 15
Other Customers (Non-PCE)41
Fiscal Year PCE Payments $388,570
PCE Statistical Data
PCE Eligible kWh - Residential Customers 744,770 Average Annual PCE Payment per Eligible
Customer
$2,089
PCE Eligible kWh - Community Facility
Customers
489,473 Average PCE Payment per Eligible kWh $0.31
Total PCE Eligible kWh 1,234,243 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.57
Average Monthly PCE Eligible kWh per
Residential Customer
363 Last Reported PCE Level (per kWh)$0.31
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,719 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
48 PCE Eligible kWh vs Total kWh Sold 47.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,795,072 Fuel Used (Gallons)201,864
Non-Diesel kWh Generated 0 Fuel Cost $676,356
Purchased kWh 0 Average Price of Fuel $3.35
Total Purchased & Generated 2,795,072 Fuel Cost per kWh sold $0.26
Annual Non-Fuel Expenses $553,422
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.47
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,101,018 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
94.0%
Community Facility kWh Sold 759,457 Line Loss (%)4.3%
Other kWh Sold (Non-PCE)767,262 Fuel Efficiency (kWh per Gallon of Diesel)13.85
Total kWh Sold 2,627,737 PH Consumption as % of Generation 1.7%
Powerhouse (PH) Consumption kWh 48,495
Total kWh Sold & PH Consumption 2,676,232
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 152 of 187
Shageluk PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 84
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 36
Community Facility Customers 9
Other Customers (Non-PCE)13
Fiscal Year PCE Payments $56,441
PCE Statistical Data
PCE Eligible kWh - Residential Customers 108,271 Average Annual PCE Payment per Eligible
Customer
$1,254
PCE Eligible kWh - Community Facility
Customers
58,914 Average PCE Payment per Eligible kWh $0.34
Total PCE Eligible kWh 167,185 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.58
Average Monthly PCE Eligible kWh per
Residential Customer
251 Last Reported PCE Level (per kWh)$0.32
Average Monthly PCE Eligible kWh per
Community Facility Customer
546 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
58 PCE Eligible kWh vs Total kWh Sold 42.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 433,196 Fuel Used (Gallons)37,201
Non-Diesel kWh Generated 0 Fuel Cost $106,997
Purchased kWh 0 Average Price of Fuel $2.88
Total Purchased & Generated 433,196 Fuel Cost per kWh sold $0.27
Annual Non-Fuel Expenses $83,850
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.48
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 130,325 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
91.9%
Community Facility kWh Sold 78,407 Line Loss (%)5.6%
Other kWh Sold (Non-PCE)189,399 Fuel Efficiency (kWh per Gallon of Diesel)11.64
Total kWh Sold 398,131 PH Consumption as % of Generation 2.5%
Powerhouse (PH) Consumption kWh 10,863
Total kWh Sold & PH Consumption 408,994
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 153 of 187
Shaktoolik PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 275
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 62
Community Facility Customers 4
Other Customers (Non-PCE)29
Fiscal Year PCE Payments $100,155
PCE Statistical Data
PCE Eligible kWh - Residential Customers 309,650 Average Annual PCE Payment per Eligible
Customer
$1,518
PCE Eligible kWh - Community Facility
Customers
63,979 Average PCE Payment per Eligible kWh $0.27
Total PCE Eligible kWh 373,629 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.55
Average Monthly PCE Eligible kWh per
Residential Customer
416 Last Reported PCE Level (per kWh)$0.26
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,333 Effective Residential Rate (per kWh)$0.29
Average Monthly PCE Eligible Community
Facility kWh per Person
19 PCE Eligible kWh vs Total kWh Sold 37.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 780,308 Fuel Used (Gallons)63,793
Non-Diesel kWh Generated 367,268 Fuel Cost $205,428
Purchased kWh 0 Average Price of Fuel $3.22
Total Purchased & Generated 1,147,576 Fuel Cost per kWh sold $0.21
Annual Non-Fuel Expenses $209,973
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.42
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 426,926 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
86.9%
Community Facility kWh Sold 157,750 Line Loss (%)4.7%
Other kWh Sold (Non-PCE)412,307 Fuel Efficiency (kWh per Gallon of Diesel)12.23
Total kWh Sold 996,983 PH Consumption as % of Generation 8.4%
Powerhouse (PH) Consumption kWh 96,968
Total kWh Sold & PH Consumption 1,093,951
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 154 of 187
Shishmaref PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 598
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 151
Community Facility Customers 11
Other Customers (Non-PCE)44
Fiscal Year PCE Payments $261,759
PCE Statistical Data
PCE Eligible kWh - Residential Customers 639,188 Average Annual PCE Payment per Eligible
Customer
$1,616
PCE Eligible kWh - Community Facility
Customers
171,634 Average PCE Payment per Eligible kWh $0.32
Total PCE Eligible kWh 810,822 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.56
Average Monthly PCE Eligible kWh per
Residential Customer
353 Last Reported PCE Level (per kWh)$0.30
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,300 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
24 PCE Eligible kWh vs Total kWh Sold 45.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,817,697 Fuel Used (Gallons)126,976
Non-Diesel kWh Generated 0 Fuel Cost $437,356
Purchased kWh 0 Average Price of Fuel $3.44
Total Purchased & Generated 1,817,697 Fuel Cost per kWh sold $0.25
Annual Non-Fuel Expenses $372,045
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.46
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 739,638 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
97.2%
Community Facility kWh Sold 329,430 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)697,463 Fuel Efficiency (kWh per Gallon of Diesel)14.32
Total kWh Sold 1,766,531 PH Consumption as % of Generation 3.0%
Powerhouse (PH) Consumption kWh 54,920
Total kWh Sold & PH Consumption 1,821,451
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 155 of 187
Shungnak PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 274
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 62
Community Facility Customers 9
Other Customers (Non-PCE)19
Fiscal Year PCE Payments $172,386
PCE Statistical Data
PCE Eligible kWh - Residential Customers 280,510 Average Annual PCE Payment per Eligible
Customer
$2,428
PCE Eligible kWh - Community Facility
Customers
142,919 Average PCE Payment per Eligible kWh $0.41
Total PCE Eligible kWh 423,429 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.81
Average Monthly PCE Eligible kWh per
Residential Customer
377 Last Reported PCE Level (per kWh)$0.54
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,323 Effective Residential Rate (per kWh)$0.28
Average Monthly PCE Eligible Community
Facility kWh per Person
43 PCE Eligible kWh vs Total kWh Sold 45.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,713,871 Fuel Used (Gallons)127,094
Non-Diesel kWh Generated 0 Fuel Cost $594,780
Purchased kWh 0 Average Price of Fuel $4.68
Total Purchased & Generated 1,713,871 Fuel Cost per kWh sold $0.64
Annual Non-Fuel Expenses $196,355
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.85
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 405,536 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
54.4%
Community Facility kWh Sold 221,229 Line Loss (%)42.1%
Other kWh Sold (Non-PCE)305,558 Fuel Efficiency (kWh per Gallon of Diesel)13.49
Total kWh Sold 932,323 PH Consumption as % of Generation 3.5%
Powerhouse (PH) Consumption kWh 59,422
Total kWh Sold & PH Consumption 991,745
Comments
Provides Power To Kobuk Via Intertie
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 156 of 187
Skagway PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/19..06/30/20
Community Population 1088
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 635
Community Facility Customers 31
Other Customers (Non-PCE)601
Fiscal Year PCE Payments $34,567
PCE Statistical Data
PCE Eligible kWh - Residential Customers 1,901,276 Average Annual PCE Payment per Eligible
Customer
$52
PCE Eligible kWh - Community Facility
Customers
732,341 Average PCE Payment per Eligible kWh $0.01
Total PCE Eligible kWh 2,633,617 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.26
Average Monthly PCE Eligible kWh per
Residential Customer
250 Last Reported PCE Level (per kWh)$0.01
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,969 Effective Residential Rate (per kWh)$0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
56 PCE Eligible kWh vs Total kWh Sold 21.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,281,226 Fuel Used (Gallons)92,062
Non-Diesel kWh Generated 1,879,908 Fuel Cost $283,845
Purchased kWh 10,109,657 Average Price of Fuel $3.08
Total Purchased & Generated 13,270,791 Fuel Cost per kWh sold $0.02
Annual Non-Fuel Expenses $1,549,836
Non-Fuel Expense per kWh Sold $0.13
Total Expense per kWh Sold $0.15
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 3,259,650 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
91.5%
Community Facility kWh Sold 807,914 Line Loss (%)7.5%
Other kWh Sold (Non-PCE)8,075,270 Fuel Efficiency (kWh per Gallon of Diesel)13.92
Total kWh Sold 12,142,834 PH Consumption as % of Generation 1.0%
Powerhouse (PH) Consumption kWh 133,244
Total kWh Sold & PH Consumption 12,276,078
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 157 of 187
Slana PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/19..06/30/20
Community Population 126
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 75
Community Facility Customers 1
Other Customers (Non-PCE)17
Fiscal Year PCE Payments $70,115
PCE Statistical Data
PCE Eligible kWh - Residential Customers 230,875 Average Annual PCE Payment per Eligible
Customer
$923
PCE Eligible kWh - Community Facility
Customers
2,772 Average PCE Payment per Eligible kWh $0.30
Total PCE Eligible kWh 233,647 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.56
Average Monthly PCE Eligible kWh per
Residential Customer
257 Last Reported PCE Level (per kWh)$0.26
Average Monthly PCE Eligible kWh per
Community Facility Customer
231 Effective Residential Rate (per kWh)$0.30
Average Monthly PCE Eligible Community
Facility kWh per Person
2 PCE Eligible kWh vs Total kWh Sold 51.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,393,915 Fuel Used (Gallons)94,659
Non-Diesel kWh Generated 0 Fuel Cost $241,307
Purchased kWh 0 Average Price of Fuel $2.55
Total Purchased & Generated 1,393,915 Fuel Cost per kWh sold $0.54
Annual Non-Fuel Expenses $283,722
Non-Fuel Expense per kWh Sold $0.63
Total Expense per kWh Sold $1.17
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 276,743 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
32.3%
Community Facility kWh Sold 2,772 Line Loss (%)65.3%
Other kWh Sold (Non-PCE)171,096 Fuel Efficiency (kWh per Gallon of Diesel)14.73
Total kWh Sold 450,611 PH Consumption as % of Generation 2.3%
Powerhouse (PH) Consumption kWh 32,510
Total kWh Sold & PH Consumption 483,121
Comments
Supplies Power To Chistochina & Mentasta
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 158 of 187
Sleetmute PCE
Utility: MIDDLE KUSKOKWIM ELECTRIC COOPERATIVE INC
Reporting Period: 07/01/19..06/30/20
Community Population 86
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 30
Community Facility Customers 6
Other Customers (Non-PCE)10
Fiscal Year PCE Payments $92,749
PCE Statistical Data
PCE Eligible kWh - Residential Customers 71,758 Average Annual PCE Payment per Eligible
Customer
$2,576
PCE Eligible kWh - Community Facility
Customers
49,931 Average PCE Payment per Eligible kWh $0.76
Total PCE Eligible kWh 121,689 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.29
Average Monthly PCE Eligible kWh per
Residential Customer
199 Last Reported PCE Level (per kWh)$0.77
Average Monthly PCE Eligible kWh per
Community Facility Customer
693 Effective Residential Rate (per kWh)$0.52
Average Monthly PCE Eligible Community
Facility kWh per Person
48 PCE Eligible kWh vs Total kWh Sold 52.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 244,683 Fuel Used (Gallons)24,736
Non-Diesel kWh Generated 0 Fuel Cost $80,221
Purchased kWh 0 Average Price of Fuel $3.24
Total Purchased & Generated 244,683 Fuel Cost per kWh sold $0.35
Annual Non-Fuel Expenses $225,749
Non-Fuel Expense per kWh Sold $0.97
Total Expense per kWh Sold $1.32
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 83,489 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
94.8%
Community Facility kWh Sold 50,912 Line Loss (%)0.5%
Other kWh Sold (Non-PCE)97,445 Fuel Efficiency (kWh per Gallon of Diesel)9.89
Total kWh Sold 231,846 PH Consumption as % of Generation 4.8%
Powerhouse (PH) Consumption kWh 11,654
Total kWh Sold & PH Consumption 243,500
Comments
kWh's Generated & Powerhouse Consumption = 11 Months
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 159 of 187
St. George PCE
Utility: CITY OF ST. GEORGE
Reporting Period: 07/01/19..06/30/20
Community Population 68
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 40
Community Facility Customers 7
Other Customers (Non-PCE)31
Fiscal Year PCE Payments $111,403
PCE Statistical Data
PCE Eligible kWh - Residential Customers 96,522 Average Annual PCE Payment per Eligible
Customer
$2,370
PCE Eligible kWh - Community Facility
Customers
49,638 Average PCE Payment per Eligible kWh $0.76
Total PCE Eligible kWh 146,160 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.00
Average Monthly PCE Eligible kWh per
Residential Customer
201 Last Reported PCE Level (per kWh)$0.76
Average Monthly PCE Eligible kWh per
Community Facility Customer
591 Effective Residential Rate (per kWh)$0.24
Average Monthly PCE Eligible Community
Facility kWh per Person
61 PCE Eligible kWh vs Total kWh Sold 33.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 540,395 Fuel Used (Gallons)45,534
Non-Diesel kWh Generated 0 Fuel Cost $322,108
Purchased kWh 0 Average Price of Fuel $7.07
Total Purchased & Generated 540,395 Fuel Cost per kWh sold $0.75
Annual Non-Fuel Expenses $32,289
Non-Fuel Expense per kWh Sold $0.07
Total Expense per kWh Sold $0.82
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 148,699 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
79.8%
Community Facility kWh Sold 74,398 Line Loss (%)14.4%
Other kWh Sold (Non-PCE)208,253 Fuel Efficiency (kWh per Gallon of Diesel)11.87
Total kWh Sold 431,350 PH Consumption as % of Generation 5.8%
Powerhouse (PH) Consumption kWh 31,464
Total kWh Sold & PH Consumption 462,814
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 160 of 187
St. Mary's; Andreafsky PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 566
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 178
Community Facility Customers 17
Other Customers (Non-PCE)57
Fiscal Year PCE Payments $250,845
PCE Statistical Data
PCE Eligible kWh - Residential Customers 691,543 Average Annual PCE Payment per Eligible
Customer
$1,286
PCE Eligible kWh - Community Facility
Customers
414,885 Average PCE Payment per Eligible kWh $0.23
Total PCE Eligible kWh 1,106,428 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.38
Average Monthly PCE Eligible kWh per
Residential Customer
324 Last Reported PCE Level (per kWh)$0.12
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,034 Effective Residential Rate (per kWh)$0.25
Average Monthly PCE Eligible Community
Facility kWh per Person
61 PCE Eligible kWh vs Total kWh Sold 40.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,819,158 Fuel Used (Gallons)160,789
Non-Diesel kWh Generated 1,747,790 Fuel Cost $465,782
Purchased kWh 0 Average Price of Fuel $2.90
Total Purchased & Generated 3,566,948 Fuel Cost per kWh sold $0.17
Annual Non-Fuel Expenses $572,837
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.38
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 831,198 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
76.3%
Community Facility kWh Sold 737,967 Line Loss (%)12.3%
Other kWh Sold (Non-PCE)1,150,754 Fuel Efficiency (kWh per Gallon of Diesel)11.31
Total kWh Sold 2,719,919 PH Consumption as % of Generation 11.5%
Powerhouse (PH) Consumption kWh 408,516
Total kWh Sold & PH Consumption 3,128,435
Comments
Provides Power To Pitkas Point Via Intertie
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 161 of 187
St. Michael PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 398
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 89
Community Facility Customers 10
Other Customers (Non-PCE)39
Fiscal Year PCE Payments $197,355
PCE Statistical Data
PCE Eligible kWh - Residential Customers 414,943 Average Annual PCE Payment per Eligible
Customer
$1,993
PCE Eligible kWh - Community Facility
Customers
268,906 Average PCE Payment per Eligible kWh $0.29
Total PCE Eligible kWh 683,849 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.54
Average Monthly PCE Eligible kWh per
Residential Customer
389 Last Reported PCE Level (per kWh)$0.28
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,241 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
56 PCE Eligible kWh vs Total kWh Sold 39.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $362,171
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.21
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 572,679 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 526,188 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)620,777 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 1,719,644 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 1,719,644
Comments
Receives Power From Stebbins Via Intertie
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 162 of 187
St. Paul PCE
Utility: ST. PAUL MUNICIPAL ELECTRIC
Reporting Period: 07/01/19..06/30/20
Community Population 390
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 135
Community Facility Customers 27
Other Customers (Non-PCE)83
Fiscal Year PCE Payments $218,978
PCE Statistical Data
PCE Eligible kWh - Residential Customers 588,052 Average Annual PCE Payment per Eligible
Customer
$1,352
PCE Eligible kWh - Community Facility
Customers
323,854 Average PCE Payment per Eligible kWh $0.24
Total PCE Eligible kWh 911,906 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.41
Average Monthly PCE Eligible kWh per
Residential Customer
363 Last Reported PCE Level (per kWh)$0.22
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,000 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per Person
69 PCE Eligible kWh vs Total kWh Sold 31.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 3,098,416 Fuel Used (Gallons)215,397
Non-Diesel kWh Generated 0 Fuel Cost $734,611
Purchased kWh 216,643 Average Price of Fuel $3.41
Total Purchased & Generated 3,315,059 Fuel Cost per kWh sold $0.26
Annual Non-Fuel Expenses $454,801
Non-Fuel Expense per kWh Sold $0.16
Total Expense per kWh Sold $0.41
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 674,034 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
86.5%
Community Facility kWh Sold 400,027 Line Loss (%)8.2%
Other kWh Sold (Non-PCE)1,794,142 Fuel Efficiency (kWh per Gallon of Diesel)14.38
Total kWh Sold 2,868,203 PH Consumption as % of Generation 5.3%
Powerhouse (PH) Consumption kWh 176,326
Total kWh Sold & PH Consumption 3,044,529
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 163 of 187
Stebbins PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 646
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 137
Community Facility Customers 10
Other Customers (Non-PCE)39
Fiscal Year PCE Payments $209,448
PCE Statistical Data
PCE Eligible kWh - Residential Customers 588,447 Average Annual PCE Payment per Eligible
Customer
$1,425
PCE Eligible kWh - Community Facility
Customers
101,835 Average PCE Payment per Eligible kWh $0.30
Total PCE Eligible kWh 690,282 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.54
Average Monthly PCE Eligible kWh per
Residential Customer
358 Last Reported PCE Level (per kWh)$0.28
Average Monthly PCE Eligible kWh per
Community Facility Customer
849 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
13 PCE Eligible kWh vs Total kWh Sold 42.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 3,518,837 Fuel Used (Gallons)241,492
Non-Diesel kWh Generated 0 Fuel Cost $761,091
Purchased kWh 0 Average Price of Fuel $3.15
Total Purchased & Generated 3,518,837 Fuel Cost per kWh sold $0.47
Annual Non-Fuel Expenses $339,926
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.68
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 758,996 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
45.9%
Community Facility kWh Sold 264,466 Line Loss (%)52.3%
Other kWh Sold (Non-PCE)590,562 Fuel Efficiency (kWh per Gallon of Diesel)14.57
Total kWh Sold 1,614,024 PH Consumption as % of Generation 1.8%
Powerhouse (PH) Consumption kWh 64,407
Total kWh Sold & PH Consumption 1,678,431
Comments
Provides Power To St. Michael Via Intertie
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 164 of 187
Stony River PCE
Utility: MIDDLE KUSKOKWIM ELECTRIC COOPERATIVE INC
Reporting Period: 07/01/19..06/30/20
Community Population 42
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 15
Community Facility Customers 5
Other Customers (Non-PCE)5
Fiscal Year PCE Payments $39,126
PCE Statistical Data
PCE Eligible kWh - Residential Customers 28,189 Average Annual PCE Payment per Eligible
Customer
$1,956
PCE Eligible kWh - Community Facility
Customers
23,153 Average PCE Payment per Eligible kWh $0.76
Total PCE Eligible kWh 51,342 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.29
Average Monthly PCE Eligible kWh per
Residential Customer
157 Last Reported PCE Level (per kWh)$0.77
Average Monthly PCE Eligible kWh per
Community Facility Customer
386 Effective Residential Rate (per kWh)$0.52
Average Monthly PCE Eligible Community
Facility kWh per Person
46 PCE Eligible kWh vs Total kWh Sold 47.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 131,229 Fuel Used (Gallons)14,615
Non-Diesel kWh Generated 0 Fuel Cost $47,414
Purchased kWh 0 Average Price of Fuel $3.24
Total Purchased & Generated 131,229 Fuel Cost per kWh sold $0.44
Annual Non-Fuel Expenses $197,494
Non-Fuel Expense per kWh Sold $1.82
Total Expense per kWh Sold $2.25
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 33,346 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
82.9%
Community Facility kWh Sold 23,153 Line Loss (%)8.8%
Other kWh Sold (Non-PCE)52,313 Fuel Efficiency (kWh per Gallon of Diesel)8.98
Total kWh Sold 108,812 PH Consumption as % of Generation 8.3%
Powerhouse (PH) Consumption kWh 10,847
Total kWh Sold & PH Consumption 119,659
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 165 of 187
Takotna PCE
Utility: TAKOTNA COMMUNITY ASSOC INC
Reporting Period: 07/01/19..06/30/20
Community Population 72
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 34
Community Facility Customers 4
Other Customers (Non-PCE)13
Fiscal Year PCE Payments $46,609
PCE Statistical Data
PCE Eligible kWh - Residential Customers 66,943 Average Annual PCE Payment per Eligible
Customer
$1,227
PCE Eligible kWh - Community Facility
Customers
23,944 Average PCE Payment per Eligible kWh $0.51
Total PCE Eligible kWh 90,887 Last Reported Residential Rate Charged
(based on 500 kWh)
$1.02
Average Monthly PCE Eligible kWh per
Residential Customer
164 Last Reported PCE Level (per kWh)$0.51
Average Monthly PCE Eligible kWh per
Community Facility Customer
499 Effective Residential Rate (per kWh)$0.51
Average Monthly PCE Eligible Community
Facility kWh per Person
28 PCE Eligible kWh vs Total kWh Sold 47.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)19,552
Non-Diesel kWh Generated 0 Fuel Cost $84,744
Purchased kWh 0 Average Price of Fuel $4.33
Total Purchased & Generated 0 Fuel Cost per kWh sold $0.44
Annual Non-Fuel Expenses $37,000
Non-Fuel Expense per kWh Sold $0.19
Total Expense per kWh Sold $0.64
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 75,805 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 23,944 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)90,979 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 190,728 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 190,728
Comments
Plant Meters Broken (kWh Generation & Powerhouse Consumption Data Not Avail.)
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 166 of 187
Tanana PCE
Utility: TANANA POWER COMPANY INC.
Reporting Period: 07/01/19..06/30/20
Community Population 204
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 105
Community Facility Customers 7
Other Customers (Non-PCE)43
Fiscal Year PCE Payments $130,813
PCE Statistical Data
PCE Eligible kWh - Residential Customers 272,405 Average Annual PCE Payment per Eligible
Customer
$1,168
PCE Eligible kWh - Community Facility
Customers
136,841 Average PCE Payment per Eligible kWh $0.32
Total PCE Eligible kWh 409,246 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.70
Average Monthly PCE Eligible kWh per
Residential Customer
216 Last Reported PCE Level (per kWh)$0.33
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,629 Effective Residential Rate (per kWh)$0.37
Average Monthly PCE Eligible Community
Facility kWh per Person
56 PCE Eligible kWh vs Total kWh Sold 35.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,287,685 Fuel Used (Gallons)92,530
Non-Diesel kWh Generated 0 Fuel Cost $275,974
Purchased kWh 0 Average Price of Fuel $2.98
Total Purchased & Generated 1,287,685 Fuel Cost per kWh sold $0.24
Annual Non-Fuel Expenses $401,875
Non-Fuel Expense per kWh Sold $0.34
Total Expense per kWh Sold $0.58
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 300,297 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
90.8%
Community Facility kWh Sold 149,285 Line Loss (%)7.0%
Other kWh Sold (Non-PCE)719,631 Fuel Efficiency (kWh per Gallon of Diesel)13.92
Total kWh Sold 1,169,213 PH Consumption as % of Generation 2.2%
Powerhouse (PH) Consumption kWh 28,516
Total kWh Sold & PH Consumption 1,197,729
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 167 of 187
Tatitlek PCE
Utility: TATITLEK VILLAGE IRA COUNCIL
Reporting Period: 07/01/19..06/30/20
Community Population 90
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 40
Community Facility Customers 5
Other Customers (Non-PCE)20
Fiscal Year PCE Payments $86,653
PCE Statistical Data
PCE Eligible kWh - Residential Customers 111,883 Average Annual PCE Payment per Eligible
Customer
$1,926
PCE Eligible kWh - Community Facility
Customers
45,396 Average PCE Payment per Eligible kWh $0.55
Total PCE Eligible kWh 157,279 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.92
Average Monthly PCE Eligible kWh per
Residential Customer
233 Last Reported PCE Level (per kWh)$0.54
Average Monthly PCE Eligible kWh per
Community Facility Customer
757 Effective Residential Rate (per kWh)$0.38
Average Monthly PCE Eligible Community
Facility kWh per Person
42 PCE Eligible kWh vs Total kWh Sold 52.1%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 409,884 Fuel Used (Gallons)33,141
Non-Diesel kWh Generated 0 Fuel Cost $142,624
Purchased kWh 0 Average Price of Fuel $4.30
Total Purchased & Generated 409,884 Fuel Cost per kWh sold $0.47
Annual Non-Fuel Expenses $0
Non-Fuel Expense per kWh Sold See Comments
Total Expense per kWh Sold $0.47
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 142,346 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
73.7%
Community Facility kWh Sold 45,396 Line Loss (%)18.0%
Other kWh Sold (Non-PCE)114,282 Fuel Efficiency (kWh per Gallon of Diesel)12.37
Total kWh Sold 302,024 PH Consumption as % of Generation 8.3%
Powerhouse (PH) Consumption kWh 33,972
Total kWh Sold & PH Consumption 335,996
Comments
Non-Fuel Costs Not Reported
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 168 of 187
Teller PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 237
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 74
Community Facility Customers 7
Other Customers (Non-PCE)35
Fiscal Year PCE Payments $94,549
PCE Statistical Data
PCE Eligible kWh - Residential Customers 264,168 Average Annual PCE Payment per Eligible
Customer
$1,167
PCE Eligible kWh - Community Facility
Customers
36,752 Average PCE Payment per Eligible kWh $0.31
Total PCE Eligible kWh 300,920 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.57
Average Monthly PCE Eligible kWh per
Residential Customer
297 Last Reported PCE Level (per kWh)$0.31
Average Monthly PCE Eligible kWh per
Community Facility Customer
438 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
13 PCE Eligible kWh vs Total kWh Sold 39.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 848,081 Fuel Used (Gallons)60,468
Non-Diesel kWh Generated 0 Fuel Cost $193,233
Purchased kWh 0 Average Price of Fuel $3.20
Total Purchased & Generated 848,081 Fuel Cost per kWh sold $0.25
Annual Non-Fuel Expenses $160,685
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.46
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 292,327 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
90.0%
Community Facility kWh Sold 175,202 Line Loss (%)3.7%
Other kWh Sold (Non-PCE)295,431 Fuel Efficiency (kWh per Gallon of Diesel)14.03
Total kWh Sold 762,960 PH Consumption as % of Generation 6.3%
Powerhouse (PH) Consumption kWh 53,374
Total kWh Sold & PH Consumption 816,334
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 169 of 187
Tenakee Springs PCE
Utility: CITY OF TENAKEE SPRINGS
Reporting Period: 07/01/19..06/30/20
Community Population 144
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 124
Community Facility Customers 14
Other Customers (Non-PCE)26
Fiscal Year PCE Payments $79,024
PCE Statistical Data
PCE Eligible kWh - Residential Customers 197,089 Average Annual PCE Payment per Eligible
Customer
$573
PCE Eligible kWh - Community Facility
Customers
28,277 Average PCE Payment per Eligible kWh $0.35
Total PCE Eligible kWh 225,366 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.55
Average Monthly PCE Eligible kWh per
Residential Customer
132 Last Reported PCE Level (per kWh)$0.34
Average Monthly PCE Eligible kWh per
Community Facility Customer
168 Effective Residential Rate (per kWh)$0.21
Average Monthly PCE Eligible Community
Facility kWh per Person
16 PCE Eligible kWh vs Total kWh Sold 67.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 388,412 Fuel Used (Gallons)30,918
Non-Diesel kWh Generated 0 Fuel Cost $113,932
Purchased kWh 0 Average Price of Fuel $3.68
Total Purchased & Generated 388,412 Fuel Cost per kWh sold $0.34
Annual Non-Fuel Expenses $106,483
Non-Fuel Expense per kWh Sold $0.32
Total Expense per kWh Sold $0.65
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 241,138 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
86.7%
Community Facility kWh Sold 28,277 Line Loss (%)7.2%
Other kWh Sold (Non-PCE)67,176 Fuel Efficiency (kWh per Gallon of Diesel)12.56
Total kWh Sold 336,591 PH Consumption as % of Generation 6.1%
Powerhouse (PH) Consumption kWh 23,729
Total kWh Sold & PH Consumption 360,320
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 170 of 187
Tetlin PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/19..06/30/20
Community Population 120
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 44
Community Facility Customers 5
Other Customers (Non-PCE)8
Fiscal Year PCE Payments $50,283
PCE Statistical Data
PCE Eligible kWh - Residential Customers 151,168 Average Annual PCE Payment per Eligible
Customer
$1,026
PCE Eligible kWh - Community Facility
Customers
76,864 Average PCE Payment per Eligible kWh $0.22
Total PCE Eligible kWh 228,032 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.37
Average Monthly PCE Eligible kWh per
Residential Customer
286 Last Reported PCE Level (per kWh)$0.18
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,281 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per Person
53 PCE Eligible kWh vs Total kWh Sold 60.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $0
Non-Fuel Expense per kWh Sold See Comments
Total Expense per kWh Sold $0.00
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 187,689 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 79,502 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)108,028 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 375,219 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 375,219
Comments
See Tok For Power Generation
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 171 of 187
Thorne Bay; Kasaan PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/19..06/30/20
Community Population 605
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 330
Community Facility Customers 29
Other Customers (Non-PCE)150
Fiscal Year PCE Payments $20,918
PCE Statistical Data
PCE Eligible kWh - Residential Customers 1,059,831 Average Annual PCE Payment per Eligible
Customer
$58
PCE Eligible kWh - Community Facility
Customers
328,810 Average PCE Payment per Eligible kWh $0.02
Total PCE Eligible kWh 1,388,641 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.27
Average Monthly PCE Eligible kWh per
Residential Customer
268 Last Reported PCE Level (per kWh)$0.02
Average Monthly PCE Eligible kWh per
Community Facility Customer
945 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
45 PCE Eligible kWh vs Total kWh Sold 42.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $0
Non-Fuel Expense per kWh Sold See Comments
Total Expense per kWh Sold $0.00
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,582,660 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 328,889 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)1,391,706 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 3,303,255 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 72,000
Total kWh Sold & PH Consumption 3,375,255
Comments
See Craig For Power Generation
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 172 of 187
Togiak PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 900
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 217
Community Facility Customers 19
Other Customers (Non-PCE)78
Fiscal Year PCE Payments $359,700
PCE Statistical Data
PCE Eligible kWh - Residential Customers 915,097 Average Annual PCE Payment per Eligible
Customer
$1,524
PCE Eligible kWh - Community Facility
Customers
241,077 Average PCE Payment per Eligible kWh $0.31
Total PCE Eligible kWh 1,156,174 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.54
Average Monthly PCE Eligible kWh per
Residential Customer
351 Last Reported PCE Level (per kWh)$0.28
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,057 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
22 PCE Eligible kWh vs Total kWh Sold 40.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 2,988,564 Fuel Used (Gallons)204,946
Non-Diesel kWh Generated 0 Fuel Cost $677,673
Purchased kWh 0 Average Price of Fuel $3.31
Total Purchased & Generated 2,988,564 Fuel Cost per kWh sold $0.24
Annual Non-Fuel Expenses $599,873
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.45
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,176,100 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
95.3%
Community Facility kWh Sold 517,180 Line Loss (%)3.1%
Other kWh Sold (Non-PCE)1,155,012 Fuel Efficiency (kWh per Gallon of Diesel)14.58
Total kWh Sold 2,848,292 PH Consumption as % of Generation 1.6%
Powerhouse (PH) Consumption kWh 48,825
Total kWh Sold & PH Consumption 2,897,117
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 173 of 187
Tok; Tanacross PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/19..06/30/20
Community Population 1350
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 771
Community Facility Customers 33
Other Customers (Non-PCE)187
Fiscal Year PCE Payments $654,997
PCE Statistical Data
PCE Eligible kWh - Residential Customers 2,792,491 Average Annual PCE Payment per Eligible
Customer
$815
PCE Eligible kWh - Community Facility
Customers
187,760 Average PCE Payment per Eligible kWh $0.22
Total PCE Eligible kWh 2,980,251 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.37
Average Monthly PCE Eligible kWh per
Residential Customer
302 Last Reported PCE Level (per kWh)$0.18
Average Monthly PCE Eligible kWh per
Community Facility Customer
474 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per Person
12 PCE Eligible kWh vs Total kWh Sold 37.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 9,747,320 Fuel Used (Gallons)677,763
Non-Diesel kWh Generated 0 Fuel Cost $1,691,803
Purchased kWh 0 Average Price of Fuel $2.50
Total Purchased & Generated 9,747,320 Fuel Cost per kWh sold $0.21
Annual Non-Fuel Expenses $1,848,431
Non-Fuel Expense per kWh Sold $0.23
Total Expense per kWh Sold $0.45
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 3,897,362 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
81.5%
Community Facility kWh Sold 187,760 Line Loss (%)16.6%
Other kWh Sold (Non-PCE)3,859,954 Fuel Efficiency (kWh per Gallon of Diesel)14.38
Total kWh Sold 7,945,076 PH Consumption as % of Generation 1.8%
Powerhouse (PH) Consumption kWh 179,600
Total kWh Sold & PH Consumption 8,124,676
Comments
Supplies Power To Dot Lake/Dot Lake Village & Tetlin
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 174 of 187
Toksook Bay PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 683
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 134
Community Facility Customers 13
Other Customers (Non-PCE)31
Fiscal Year PCE Payments $251,750
PCE Statistical Data
PCE Eligible kWh - Residential Customers 616,701 Average Annual PCE Payment per Eligible
Customer
$1,713
PCE Eligible kWh - Community Facility
Customers
283,299 Average PCE Payment per Eligible kWh $0.28
Total PCE Eligible kWh 900,000 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.58
Average Monthly PCE Eligible kWh per
Residential Customer
384 Last Reported PCE Level (per kWh)$0.30
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,816 Effective Residential Rate (per kWh)$0.29
Average Monthly PCE Eligible Community
Facility kWh per Person
35 PCE Eligible kWh vs Total kWh Sold 57.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 3,308,089 Fuel Used (Gallons)235,610
Non-Diesel kWh Generated 325,495 Fuel Cost $755,719
Purchased kWh 0 Average Price of Fuel $3.21
Total Purchased & Generated 3,633,584 Fuel Cost per kWh sold $0.48
Annual Non-Fuel Expenses $330,107
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.69
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 767,122 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
43.1%
Community Facility kWh Sold 479,013 Line Loss (%)53.8%
Other kWh Sold (Non-PCE)321,267 Fuel Efficiency (kWh per Gallon of Diesel)14.04
Total kWh Sold 1,567,402 PH Consumption as % of Generation 3.0%
Powerhouse (PH) Consumption kWh 110,153
Total kWh Sold & PH Consumption 1,677,555
Comments
Provides Power To Nightmute & Tununak Via Intertie
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 175 of 187
Tuntutuliak PCE
Utility: TUNTUTULIAK COMMUNITY
Reporting Period: 07/01/19..06/30/20
Community Population 466
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 138
Community Facility Customers 10
Other Customers (Non-PCE)41
Fiscal Year PCE Payments $202,285
PCE Statistical Data
PCE Eligible kWh - Residential Customers 461,244 Average Annual PCE Payment per Eligible
Customer
$1,367
PCE Eligible kWh - Community Facility
Customers
31,414 Average PCE Payment per Eligible kWh $0.41
Total PCE Eligible kWh 492,658 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.65
Average Monthly PCE Eligible kWh per
Residential Customer
279 Last Reported PCE Level (per kWh)$0.39
Average Monthly PCE Eligible kWh per
Community Facility Customer
262 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
6 PCE Eligible kWh vs Total kWh Sold 43.8%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,146,650 Fuel Used (Gallons)108,249
Non-Diesel kWh Generated 118,495 Fuel Cost $345,084
Purchased kWh 0 Average Price of Fuel $3.19
Total Purchased & Generated 1,265,145 Fuel Cost per kWh sold $0.31
Annual Non-Fuel Expenses $379,995
Non-Fuel Expense per kWh Sold $0.34
Total Expense per kWh Sold $0.65
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 515,007 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
88.8%
Community Facility kWh Sold 32,854 Line Loss (%)9.0%
Other kWh Sold (Non-PCE)576,059 Fuel Efficiency (kWh per Gallon of Diesel)10.59
Total kWh Sold 1,123,920 PH Consumption as % of Generation 2.1%
Powerhouse (PH) Consumption kWh 27,031
Total kWh Sold & PH Consumption 1,150,951
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 176 of 187
Tununak PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 370
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 90
Community Facility Customers 9
Other Customers (Non-PCE)26
Fiscal Year PCE Payments $117,864
PCE Statistical Data
PCE Eligible kWh - Residential Customers 345,495 Average Annual PCE Payment per Eligible
Customer
$1,191
PCE Eligible kWh - Community Facility
Customers
68,130 Average PCE Payment per Eligible kWh $0.28
Total PCE Eligible kWh 413,625 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.58
Average Monthly PCE Eligible kWh per
Residential Customer
320 Last Reported PCE Level (per kWh)$0.30
Average Monthly PCE Eligible kWh per
Community Facility Customer
631 Effective Residential Rate (per kWh)$0.29
Average Monthly PCE Eligible Community
Facility kWh per Person
15 PCE Eligible kWh vs Total kWh Sold 42.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)0
Non-Diesel kWh Generated 0 Fuel Cost $0
Purchased kWh 0 Average Price of Fuel $0.00
Total Purchased & Generated 0 Fuel Cost per kWh sold See Comments
Annual Non-Fuel Expenses $204,436
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.21
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 401,607 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 217,673 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)351,417 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 970,697 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 0
Total kWh Sold & PH Consumption 970,697
Comments
Receives Power From Toksook Bay Via Intertie
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 177 of 187
Twin Hills PCE
Utility: TWIN HILLS VILLAGE COUNCIL
Reporting Period: 07/01/19..06/30/20
Community Population 96
Last Reported Month April
No. of Monthly Payments Made 10
Residential Customers 34
Community Facility Customers 6
Other Customers (Non-PCE)8
Fiscal Year PCE Payments $30,241
PCE Statistical Data
PCE Eligible kWh - Residential Customers 73,996 Average Annual PCE Payment per Eligible
Customer
$756
PCE Eligible kWh - Community Facility
Customers
23,302 Average PCE Payment per Eligible kWh $0.31
Total PCE Eligible kWh 97,298 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.51
Average Monthly PCE Eligible kWh per
Residential Customer
218 Last Reported PCE Level (per kWh)$0.31
Average Monthly PCE Eligible kWh per
Community Facility Customer
388 Effective Residential Rate (per kWh)$0.19
Average Monthly PCE Eligible Community
Facility kWh per Person
24 PCE Eligible kWh vs Total kWh Sold 34.2%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 0 Fuel Used (Gallons)32,233
Non-Diesel kWh Generated 0 Fuel Cost $102,701
Purchased kWh 0 Average Price of Fuel $3.19
Total Purchased & Generated 0 Fuel Cost per kWh sold $0.36
Annual Non-Fuel Expenses $14,523
Non-Fuel Expense per kWh Sold $0.05
Total Expense per kWh Sold $0.41
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 107,892 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 23,302 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)153,373 Fuel Efficiency (kWh per Gallon of Diesel)N/A
Total kWh Sold 284,567 PH Consumption as % of Generation N/A
Powerhouse (PH) Consumption kWh 31,353
Total kWh Sold & PH Consumption 315,920
Comments
Utility Only Submitted 10 Monthly Reports. kWh Generation Data Not Available.
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 178 of 187
Unalakleet PCE
Utility: UNALAKLEET VALLEY ELECTRIC
Reporting Period: 07/01/19..06/30/20
Community Population 722
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 273
Community Facility Customers 27
Other Customers (Non-PCE)89
Fiscal Year PCE Payments $223,244
PCE Statistical Data
PCE Eligible kWh - Residential Customers 999,275 Average Annual PCE Payment per Eligible
Customer
$744
PCE Eligible kWh - Community Facility
Customers
359,901 Average PCE Payment per Eligible kWh $0.16
Total PCE Eligible kWh 1,359,176 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.46
Average Monthly PCE Eligible kWh per
Residential Customer
305 Last Reported PCE Level (per kWh)$0.16
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,111 Effective Residential Rate (per kWh)$0.31
Average Monthly PCE Eligible Community
Facility kWh per Person
42 PCE Eligible kWh vs Total kWh Sold 33.5%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 3,645,284 Fuel Used (Gallons)239,396
Non-Diesel kWh Generated 790,395 Fuel Cost $634,529
Purchased kWh 0 Average Price of Fuel $2.65
Total Purchased & Generated 4,435,679 Fuel Cost per kWh sold $0.16
Annual Non-Fuel Expenses $0
Non-Fuel Expense per kWh Sold See Comments
Total Expense per kWh Sold $0.16
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,340,498 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
91.5%
Community Facility kWh Sold 375,951 Line Loss (%)4.9%
Other kWh Sold (Non-PCE)2,342,445 Fuel Efficiency (kWh per Gallon of Diesel)15.23
Total kWh Sold 4,058,894 PH Consumption as % of Generation 3.6%
Powerhouse (PH) Consumption kWh 159,360
Total kWh Sold & PH Consumption 4,218,254
Comments
Non-Fuel Costs Not Reported.
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 179 of 187
Unalaska PCE
Utility: CITY OF UNALASKA
Reporting Period: 07/01/19..06/30/20
Community Population 4333
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 776
Community Facility Customers 58
Other Customers (Non-PCE)195
Fiscal Year PCE Payments $567,378
PCE Statistical Data
PCE Eligible kWh - Residential Customers 1,883,310 Average Annual PCE Payment per Eligible
Customer
$680
PCE Eligible kWh - Community Facility
Customers
3,077,749 Average PCE Payment per Eligible kWh $0.11
Total PCE Eligible kWh 4,961,059 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.33
Average Monthly PCE Eligible kWh per
Residential Customer
202 Last Reported PCE Level (per kWh)$0.04
Average Monthly PCE Eligible kWh per
Community Facility Customer
4,422 Effective Residential Rate (per kWh)$0.29
Average Monthly PCE Eligible Community
Facility kWh per Person
59 PCE Eligible kWh vs Total kWh Sold 9.7%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 49,682,599 Fuel Used (Gallons)3,005,191
Non-Diesel kWh Generated 0 Fuel Cost $6,664,857
Purchased kWh 0 Average Price of Fuel $2.22
Total Purchased & Generated 49,682,599 Fuel Cost per kWh sold $0.13
Annual Non-Fuel Expenses $5,196,057
Non-Fuel Expense per kWh Sold $0.10
Total Expense per kWh Sold $0.23
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 3,765,289 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
See Comments
Community Facility kWh Sold 3,077,749 Line Loss (%)See Comments
Other kWh Sold (Non-PCE)44,523,014 Fuel Efficiency (kWh per Gallon of Diesel)16.53
Total kWh Sold 51,366,052 PH Consumption as % of Generation 2.2%
Powerhouse (PH) Consumption kWh 1,079,301
Total kWh Sold & PH Consumption 52,445,353
Comments
kWh's Generated, Fuel Used & Fuel Costs = 11 Months
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 180 of 187
Upper Kalskag PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 227
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 64
Community Facility Customers 3
Other Customers (Non-PCE)28
Fiscal Year PCE Payments $84,859
PCE Statistical Data
PCE Eligible kWh - Residential Customers 265,264 Average Annual PCE Payment per Eligible
Customer
$1,267
PCE Eligible kWh - Community Facility
Customers
20,186 Average PCE Payment per Eligible kWh $0.30
Total PCE Eligible kWh 285,450 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.55
Average Monthly PCE Eligible kWh per
Residential Customer
345 Last Reported PCE Level (per kWh)$0.28
Average Monthly PCE Eligible kWh per
Community Facility Customer
561 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
7 PCE Eligible kWh vs Total kWh Sold 35.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 1,581,273 Fuel Used (Gallons)115,246
Non-Diesel kWh Generated 0 Fuel Cost $341,994
Purchased kWh 0 Average Price of Fuel $2.97
Total Purchased & Generated 1,581,273 Fuel Cost per kWh sold $0.43
Annual Non-Fuel Expenses $168,755
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.64
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 348,861 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
50.7%
Community Facility kWh Sold 116,542 Line Loss (%)46.4%
Other kWh Sold (Non-PCE)335,872 Fuel Efficiency (kWh per Gallon of Diesel)13.72
Total kWh Sold 801,275 PH Consumption as % of Generation 2.9%
Powerhouse (PH) Consumption kWh 46,390
Total kWh Sold & PH Consumption 847,665
Comments
Provides Power To Lower Kalskag Via Intertie
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 181 of 187
Venetie PCE
Utility: VENETIE VILLAGE ELECTRIC
Reporting Period: 07/01/19..06/30/20
Community Population 174
Last Reported Month June
No. of Monthly Payments Made 10
Residential Customers 94
Community Facility Customers 7
Other Customers (Non-PCE)17
Fiscal Year PCE Payments $95,179
PCE Statistical Data
PCE Eligible kWh - Residential Customers 169,254 Average Annual PCE Payment per Eligible
Customer
$942
PCE Eligible kWh - Community Facility
Customers
67,881 Average PCE Payment per Eligible kWh $0.40
Total PCE Eligible kWh 237,135 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.90
Average Monthly PCE Eligible kWh per
Residential Customer
180 Last Reported PCE Level (per kWh)$0.33
Average Monthly PCE Eligible kWh per
Community Facility Customer
970 Effective Residential Rate (per kWh)$0.57
Average Monthly PCE Eligible Community
Facility kWh per Person
39 PCE Eligible kWh vs Total kWh Sold 38.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 750,100 Fuel Used (Gallons)67,824
Non-Diesel kWh Generated 0 Fuel Cost $302,817
Purchased kWh 0 Average Price of Fuel $4.46
Total Purchased & Generated 750,100 Fuel Cost per kWh sold $0.50
Annual Non-Fuel Expenses $29,645
Non-Fuel Expense per kWh Sold $0.05
Total Expense per kWh Sold $0.55
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 189,949 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
81.2%
Community Facility kWh Sold 92,548 Line Loss (%)16.2%
Other kWh Sold (Non-PCE)326,704 Fuel Efficiency (kWh per Gallon of Diesel)11.06
Total kWh Sold 609,201 PH Consumption as % of Generation 2.6%
Powerhouse (PH) Consumption kWh 19,600
Total kWh Sold & PH Consumption 628,801
Comments
Only 3 Months Of Non-Fuel Costs Reported.
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 182 of 187
Wainwright PCE
Utility: NORTH SLOPE BOROUGH
Reporting Period: 07/01/19..06/30/20
Community Population 555
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 151
Community Facility Customers 3
Other Customers (Non-PCE)75
Fiscal Year PCE Payments $6,704
PCE Statistical Data
PCE Eligible kWh - Residential Customers 450,246 Average Annual PCE Payment per Eligible
Customer
$44
PCE Eligible kWh - Community Facility
Customers
87,667 Average PCE Payment per Eligible kWh $0.01
Total PCE Eligible kWh 537,913 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.22
Average Monthly PCE Eligible kWh per
Residential Customer
248 Last Reported PCE Level (per kWh)$0.00
Average Monthly PCE Eligible kWh per
Community Facility Customer
2,435 Effective Residential Rate (per kWh)$0.22
Average Monthly PCE Eligible Community
Facility kWh per Person
13 PCE Eligible kWh vs Total kWh Sold 8.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 7,587,940 Fuel Used (Gallons)559,197
Non-Diesel kWh Generated 0 Fuel Cost $1,897,915
Purchased kWh 0 Average Price of Fuel $3.39
Total Purchased & Generated 7,587,940 Fuel Cost per kWh sold $0.31
Annual Non-Fuel Expenses $1,121,363
Non-Fuel Expense per kWh Sold $0.18
Total Expense per kWh Sold $0.49
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,315,165 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
82.0%
Community Facility kWh Sold 87,667 Line Loss (%)11.2%
Other kWh Sold (Non-PCE)4,815,817 Fuel Efficiency (kWh per Gallon of Diesel)13.57
Total kWh Sold 6,218,649 PH Consumption as % of Generation 6.9%
Powerhouse (PH) Consumption kWh 522,929
Total kWh Sold & PH Consumption 6,741,578
Comments
Residential PCE Level = $0.00 Per Eligible kWh
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 183 of 187
Wales PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 165
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 40
Community Facility Customers 5
Other Customers (Non-PCE)23
Fiscal Year PCE Payments $74,910
PCE Statistical Data
PCE Eligible kWh - Residential Customers 165,278 Average Annual PCE Payment per Eligible
Customer
$1,665
PCE Eligible kWh - Community Facility
Customers
48,806 Average PCE Payment per Eligible kWh $0.35
Total PCE Eligible kWh 214,084 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.61
Average Monthly PCE Eligible kWh per
Residential Customer
344 Last Reported PCE Level (per kWh)$0.34
Average Monthly PCE Eligible kWh per
Community Facility Customer
813 Effective Residential Rate (per kWh)$0.27
Average Monthly PCE Eligible Community
Facility kWh per Person
25 PCE Eligible kWh vs Total kWh Sold 35.0%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 661,291 Fuel Used (Gallons)45,861
Non-Diesel kWh Generated 0 Fuel Cost $153,253
Purchased kWh 0 Average Price of Fuel $3.34
Total Purchased & Generated 661,291 Fuel Cost per kWh sold $0.25
Annual Non-Fuel Expenses $128,874
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.46
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 215,352 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
92.5%
Community Facility kWh Sold 146,214 Line Loss (%)3.5%
Other kWh Sold (Non-PCE)250,346 Fuel Efficiency (kWh per Gallon of Diesel)14.42
Total kWh Sold 611,912 PH Consumption as % of Generation 4.0%
Powerhouse (PH) Consumption kWh 26,359
Total kWh Sold & PH Consumption 638,271
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 184 of 187
Whale Pass PCE
Utility: ALASKA POWER COMPANY
Reporting Period: 07/01/19..06/30/20
Community Population 57
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 86
Community Facility Customers 2
Other Customers (Non-PCE)15
Fiscal Year PCE Payments $2,866
PCE Statistical Data
PCE Eligible kWh - Residential Customers 194,019 Average Annual PCE Payment per Eligible
Customer
$33
PCE Eligible kWh - Community Facility
Customers
6,625 Average PCE Payment per Eligible kWh $0.01
Total PCE Eligible kWh 200,644 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.27
Average Monthly PCE Eligible kWh per
Residential Customer
188 Last Reported PCE Level (per kWh)$0.02
Average Monthly PCE Eligible kWh per
Community Facility Customer
276 Effective Residential Rate (per kWh)$0.26
Average Monthly PCE Eligible Community
Facility kWh per Person
10 PCE Eligible kWh vs Total kWh Sold 53.6%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 435,037 Fuel Used (Gallons)33,270
Non-Diesel kWh Generated 0 Fuel Cost $87,504
Purchased kWh 0 Average Price of Fuel $2.63
Total Purchased & Generated 435,037 Fuel Cost per kWh sold $0.23
Annual Non-Fuel Expenses $59,957
Non-Fuel Expense per kWh Sold $0.16
Total Expense per kWh Sold $0.39
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 278,064 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
86.0%
Community Facility kWh Sold 6,625 Line Loss (%)11.2%
Other kWh Sold (Non-PCE)89,322 Fuel Efficiency (kWh per Gallon of Diesel)13.08
Total kWh Sold 374,011 PH Consumption as % of Generation 2.8%
Powerhouse (PH) Consumption kWh 12,187
Total kWh Sold & PH Consumption 386,198
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 185 of 187
White Mountain PCE
Utility: CITY OF WHITE MOUNTAIN
Reporting Period: 07/01/19..06/30/20
Community Population 194
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 65
Community Facility Customers 8
Other Customers (Non-PCE)28
Fiscal Year PCE Payments $90,326
PCE Statistical Data
PCE Eligible kWh - Residential Customers 225,254 Average Annual PCE Payment per Eligible
Customer
$1,237
PCE Eligible kWh - Community Facility
Customers
105,648 Average PCE Payment per Eligible kWh $0.27
Total PCE Eligible kWh 330,902 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.55
Average Monthly PCE Eligible kWh per
Residential Customer
289 Last Reported PCE Level (per kWh)$0.27
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,101 Effective Residential Rate (per kWh)$0.28
Average Monthly PCE Eligible Community
Facility kWh per Person
45 PCE Eligible kWh vs Total kWh Sold 43.9%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 902,819 Fuel Used (Gallons)66,715
Non-Diesel kWh Generated 0 Fuel Cost $182,715
Purchased kWh 0 Average Price of Fuel $2.74
Total Purchased & Generated 902,819 Fuel Cost per kWh sold $0.24
Annual Non-Fuel Expenses $169,717
Non-Fuel Expense per kWh Sold $0.23
Total Expense per kWh Sold $0.47
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 253,490 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
83.4%
Community Facility kWh Sold 106,935 Line Loss (%)10.7%
Other kWh Sold (Non-PCE)392,853 Fuel Efficiency (kWh per Gallon of Diesel)13.53
Total kWh Sold 753,278 PH Consumption as % of Generation 5.8%
Powerhouse (PH) Consumption kWh 52,571
Total kWh Sold & PH Consumption 805,849
Comments
Non-Fuel Costs = 11 Months
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.
Page 186 of 187
Yakutat PCE
Utility: ALASKA VILLAGE ELECTRIC COOP
Reporting Period: 07/01/19..06/30/20
Community Population 523
Last Reported Month June
No. of Monthly Payments Made 12
Residential Customers 270
Community Facility Customers 28
Other Customers (Non-PCE)153
Fiscal Year PCE Payments $369,756
PCE Statistical Data
PCE Eligible kWh - Residential Customers 1,063,818 Average Annual PCE Payment per Eligible
Customer
$1,241
PCE Eligible kWh - Community Facility
Customers
402,386 Average PCE Payment per Eligible kWh $0.25
Total PCE Eligible kWh 1,466,204 Last Reported Residential Rate Charged
(based on 500 kWh)
$0.40
Average Monthly PCE Eligible kWh per
Residential Customer
328 Last Reported PCE Level (per kWh)$0.19
Average Monthly PCE Eligible kWh per
Community Facility Customer
1,198 Effective Residential Rate (per kWh)$0.21
Average Monthly PCE Eligible Community
Facility kWh per Person
64 PCE Eligible kWh vs Total kWh Sold 27.4%
Additional Statistical Data Reported by Community*
Generated and Purchased kWh Generation Costs
Diesel kWh Generated 5,974,703 Fuel Used (Gallons)411,215
Non-Diesel kWh Generated 0 Fuel Cost $1,123,410
Purchased kWh 0 Average Price of Fuel $2.73
Total Purchased & Generated 5,974,703 Fuel Cost per kWh sold $0.21
Annual Non-Fuel Expenses $1,127,727
Non-Fuel Expense per kWh Sold $0.21
Total Expense per kWh Sold $0.42
Consumed and Sold kWh Efficiency and Line Loss
Residential kWh Sold 1,346,576 Consumed vs Generated (kWh Sold vs
Generated-Purchased)
89.6%
Community Facility kWh Sold 1,222,222 Line Loss (%)8.2%
Other kWh Sold (Non-PCE)2,785,829 Fuel Efficiency (kWh per Gallon of Diesel)14.53
Total kWh Sold 5,354,627 PH Consumption as % of Generation 2.2%
Powerhouse (PH) Consumption kWh 132,665
Total kWh Sold & PH Consumption 5,487,292
Comments
*The data contained in this report is primarily based on information submitted by the utility with their monthly PCE reports. Changes to
the reported data and/or significant anomalies have been noted in the comments.