HomeMy WebLinkAboutGrayling Biomass Feasibility Study - Oct 2014 - REF Grant 7060933 Organized Village of Grayling Biomass Heat Pre-Feasibility Study Prepared for Interior Regional Housing Authority October 17, 2014 Prepared by: Energy Action, Wynne Auld With Support from: The Alaska Energy Authority 1231 W. Northern Lights #578 Anchorage, AK 99503 www.energyaction.info (907) 744-1085 Page 2 of 16 Contents Acknowledgements ....................................................................................................................................... 3 Community Contact Information .................................................................................................................. 3 Summary of Findings..................................................................................................................................... 4 Statement of Purpose ................................................................................................................................... 4 Community & Facility Information................................................................................................................ 5 Biomass Resource Availability ....................................................................................................................... 6 Site Control ................................................................................................................................................... 6 Permitting ..................................................................................................................................................... 6 Proposed Biomass System ............................................................................................................................ 7 Alternatives Considered ............................................................................................................................ 8 Heat Load & Biomass Operating Requirements ......................................................................................... 10 Opinion of Probable Cost ............................................................................................................................ 12 Financial Analysis ........................................................................................................................................ 14 Financial Summary .................................................................................................................................. 14 Benefit/ Cost Model ................................................................................................................................ 14 Sensitivity Analysis .................................................................................................................................. 16 Recommendations ...................................................................................................................................... 16 Figures Figure 1: Biomass Project Site Map .............................................................................................................. 9 Figure 2: Fuel Energy Values ....................................................................................................................... 10 Figure 3: Current Annual Fuel Use & Cost .................................................................................................. 10 Figure 4: Projected Annual Fuel Use & Cost, Biomass Project ................................................................... 10 Figure 5: Biomass Stoking Requirements.................................................................................................... 10 Figure 6: Biomass O&M Costs (non-stoking) .............................................................................................. 10 Figure 7: Force Account Summary .............................................................................................................. 12 Figure 8: Force Account Detail .................................................................................................................... 13 Appendix A—Biomass Technology B – Utility Receipts C – Site Control D – Site Photos Page 3 of 16 Acknowledgements Energy Action thanks the following representatives for their assistance with this assessment: Steven Graham, Head of Maintenance, Iditarod Area School District Gabe Nicholi, Iditarod Area School District School Board, and Chief, Organized Village of Grayling Rachel Freireich, Tribal Administrator, Organized Village of Grayling Russell Snyder, Grants Coordinator, Interior Regional Housing Authority Steven J. Stassel, P.E., Gray Stassel Engineering Community Contact Information Organized Village of Grayling Contact: Gabriel Nicholi Sr., Chief PO Box 49, Grayling, AK 99590 P. (907) 453-5116 F. (907) 453-5146 Chief, Gabriel Nicholi, gnicholi@iditarodsd.org Tribal Administrator, Rachel Freireich, rachel.freireich@tananachiefs.org City of Grayling Contact: Shirley Clark, Mayor PO Box 89, Grayling, AK 99590 P. (907) 453-5148 F. (907) 453-5223 cityofgrayling@yahoo.com Iditarod Area School District Contact: Steve Graham, Head of Maintenance PO Box 90, McGrath, AK 99627 P. (907) 524-1200 F. (907) 524-3217 sgraham@iditarodsd.org Page 4 of 16 Summary of Findings The School Board of the Iditarod Area School District has expressed interest in assessments to determine good candidates for biomass heat systems in District buildings. This pre-feasibility assessment considers biomass heat at the main school building of the David Louis Memorial School, located in the Organized Village of Grayling. The proposed biomass project would use an estimated 86 cords per year to displace about 85% of the main School building’s fuel oil consumption, which totals 10,000 gallons per year. The project is considered financially unfeasible at this time, largely because the local price of cordwood does not represent sufficient savings over the purchase price of fuel oil. The project also faces technical challenges, since cordwood systems are not very effective when serving building heat loads that operate in a narrow temperature range, such as 180 / 160°F. It is recommended that the District consider other ways of reducing energy costs, which may include energy management, retro-commissioning, energy efficiency upgrades, and other types of renewable energy. Statement of Purpose Since 2008, the Alaska State Legislature has supported renewable electric and thermal energy projects through the Renewable Energy Grant Recommendation Program, administered by the Alaska Energy Authority. In Round 6 of the Program, the Interior Regional Housing Authority, which seeks opportunities to promote community self-sufficiency through community energy projects, received money to complete pre-feasibility studies of biomass heat in community buildings in seven villages. The following pre-feasibility study has been funded through that grant. Page 5 of 16 Community & Facility Information The Organized Village of Grayling (population 188) is an Alaska Native community located in Interior Alaska on the west bank of the Yukon River, east of the Nulato Hills. It is 18 air miles north of Anvik. Grayling transportation facilities include cargo barge access and gravel airstrip. Grayling has a 4,000’ x 75’ gravel runway. The Iditarod Area School District (IASD) owns and operates the David Louis Memorial School. The David Louis Memorial School was selected for pre-feasibility assessment because it is the largest heat load in the community, and the School Board has expressed interest in biomass heat systems. The School District is governed by a School Board and managed by a Superintendent. The maintenance department of led by the Head of Maintenance, Steve Graham. Fuel is purchased by IASD in Grayling for $3.69 per gallon (See Appendix B). Delivery is by barge. The current going rate for cordwood is $375 per cord (public meeting discussion, May 14, 2014). Electricity is 64.38 cents per kWh, delivered from the AVEC power plant in the Organized Village of Grayling (See Appendix B). Grayling is located on the 100-year floodplain of the Yukon River. The recommended building elevation is 86.57’. The top of the first step on the David Louis Memorial School is 83.56’. Meeting the recommended building elevation for the project will require a significant elevated foundation. The proposed project building is the main school building (“School”) at the David Louis Memorial School. The David Louis Memorial School includes the School, a generator building, and a teacher housing duplex. The School was built in 1984 and is about 18,500 ft2. Based on available records and discussions with maintenance personnel, the School uses about 10,000 gallons of fuel oil #1 per year. The boilers are turned off during summer. The generator building and teacher housing duplex are estimated to use 450 and 1,000 gallons per year, respectively (See Appendix B). A modular boiler room that is located about 20’ east of the School contains the School oil boilers. The two (2) fuel oil boilers are Burnham V904A, each with 420,000 Btu net output. The hi /lo setting is 180 /160°F. Heat emitters include baseboard with thermostatic radiator valves, unit heaters, fan convector heaters, and air handling system (for the gymnasium). The air handling system is turned on manually when gym activities are underway. One 80-gallon Amtrol BoilerMate produces domestic hot water from the boilers. Page 6 of 16 Biomass Resource Availability This pre-feasibility study was completed simultaneous to a reconnaissance-level biomass resource assessment by Tanana Chiefs Conference, which will be complete in fall 2014. The draft biomass resource assessment takes account of biomass stocking by ownership, resource distance from the Organized Village of Grayling, estimated delivered cost per dry ton, and other factors. In summary, within a 5-mile radius of the Organized Village of Grayling, there are approximately 617,000 cords of biomass, with nearly 94% of this material located on Hee-Yea-Lingde Corporation lands. The average cost per cord within a 5-mile radius of Organized Village of Grayling is $87.76. This figure includes harvest, stumpage, administration, and transport costs, but does not include the cost of processing logs into cordwood or profit. Site Control The proposed project site is vested in “State of Alaska Department of Education” (Appendix C). Permitting Applicable project permitting is considered below:  The Alaska Department of Public Safety, Division of Fire and Life Safety must approve the project plans before construction is started. Mechanical and electrical review is limited to that which is necessary to confirm compliance with fire and life safety requirements.  Commercial harvests associated with the project may or may not be required to comply with the Alaska Forest Practices and Resources Act. While most commercial operations are required to comply, commercial operations of minor or small scale are sometimes exempted. The Act addresses forest management along water bodies, erosion mitigation, and reforestation.  The 40CFR63 NESHAP Rule does not apply to the project. The Rule does not apply to a hot water heater, which is defined in Subpart 6J as a boiler with a heat input capacity is less than 1.6 MMBtu/hr and that does not generate steam.  If State or Federal money is used to construct the project, the Alaska Department of Natural Resources Office of History and Archaeology, State Historic Preservation Office should review project plans to determine whether historic, prehistoric, or archaeological resources are likely to be affected. The Office also offers suggestions to mitigate potential effects on resources. Page 7 of 16 Proposed Biomass System The proposed system is 975,000 Btu of cordwood boiler capacity with hydronic heat storage, to be located in a stand-alone project building on the north side of the School. The proposed site is controlled by the Iditarod Area School District, has sufficient space for the project, and offers good access to the School’s boiler room module and other mechanical systems. Cordwood systems are not very effective when serving building heat systems that operate in a narrow temperature range, such at 180 /160°F. The project building currently operates in this range, and the biomass boiler operating and maintenance requirements have been modeled to maintain the existing temperature set points. The following assumptions were made for the purpose of completing the pre-feasibility assessment, and are not a substitute for heat load calculations and boiler sizing to be completed by the project engineer during project development:  Annual consumption of 10,000 gallons of fuel oil per year, 95% of which serves space heat load, 5% of which serves domestic hot water  Boiler are turned off during summer, from May 20 through August 20  Three (3) 325,000 cordwood boilers with 1,830 gallons of water storage each, delta T = 40°F  Maximum 4 firings per day per boiler, with additional heat demand served by oil. Each firing requires 20 minutes labor  Annual inflation o Biomass O&M and scheduled repairs – 1.5% o Cordwood – 3.0% o Oil O&M and scheduled repairs – 1.5% o Oil – 4.8%  Input prices, year 1 o Cordwood -- $375/cord o Oil -- $3.69/gal o Loaded labor rate -- $20.17/ hr The project building cost was modeled as modified conex shipping containers bolted to wood timbers, as detailed on the Opinion of Probable Cost below. Modifications to the conex are necessary to comply with the Alaska Department of Public Safety, Life and Fire Safety. The cost of modification has been included in the Opinion of Probable Cost. At least one barge company that serves Grayling has confirmed the ability to unload the materials from the barge and move them to the project site if the total container weight is less than 21,000 lbs. Page 8 of 16 Alternatives Considered The David Louis Memorial School teacher housing duplex and generator buildings were not evaluated for biomass because of their relatively small heat loads. They are located approximately 400’ and 325’ from the School, respectively. These buildings could be economically heated with cordwood stoves. The existing tribal office building was not evaluated for biomass energy because it has been replaced by the new Multi-Use Facility, which is outfitted with a cordwood boiler. The new Multi-Use Facility will be in service in July 2014. According to the Tribal Administrator, there are no plans for the Organized Village of Grayling to continue to use the existing tribal office building. The Water Plant was not evaluated for biomass heat because the Alaska Native Tribal Health Consortium is working with the building owner, the City of Grayling, to develop a recovered heat project at that site. The City office building was not evaluated for biomass heat because the anticipated heat load is less than 1,500 gallons per year, and because the City did not express interest to participate in this assessment. Page 9 of 16 Figure 1: Biomass Project Site Map Page 10 of 16 Heat Load & Biomass Operating Requirements Figure 2: Fuel Energy Values Figure 3: Current Annual Fuel Use & Cost Figure 4: Projected Annual Fuel Use & Cost, Biomass Project Figure 5: Biomass Stoking Requirements Gross Btu/unit System efficiency Delivered Btu/unit Gross $/unit Delivered $/MMBtu Oil (gal)134,500 80%107,600 $ 3.69 34.29$ Biomass, 20% MC* (cord) 16,400,000 65%10,660,000 $ 375 35.18$ *MC is Moisture Content. Moisture in biomass fuel evaporates and absorbs energy in combustion, thereby decreasing the net energy value of the fuel. Facility Fuel Oil (gal)$ / gal Annual Fuel Cost School 10,000 3.69$ 36,900$ Total 36,900$ 15%Oil 85%Biomass 8500 gallons displaced Facility Fuel Type Units $ / unit Annual Fuel Cost School Biomass, 20% MC* (cord) 85.8 375$ 32,174$ School Oil (gal)1500 3.69$ 5,535$ Total $ 37,709 Facility Total Stokings per Yr Stoking Hrs Per Yr $ / hr Annual Stoking Cost School 1865 622 20.17$ 12,537$ Page 11 of 16 Figure 6: Biomass O&M Costs (non-stoking) Boiler size (Btu) Boiler fuel Cost of Labor Cost of Electricity Number of Stokings MATERIALS Yrs to replacement Cost per Lifetime Lower Gasket 23$ 5 92$ Motor mount 27$ 10 54$ Rear cleanout gasket kit 46$ 10 92$ Manway cover gasket 19$ 10 38$ 5" cleaning brush 24$ 5 96$ Motor assembly 518$ 12 863$ 3/4 HP motor 353$ 12 588$ Motor mount kit 87$ 12 145$ Motor mount ring & screws 17$ 12 28$ Misc. 250$ 5 1,000$ Anode Rod 98$ 5 392$ Chemicals 250$ 1 5,000$ Total Cost per Lifetime 8,389$ Straight-Line Average Cost per Yr.419$ LABOR Hours labor Yrs to labor Cost per Lifetime Water test and replace 0.50 1 202$ Cleanout covers and heat xger 2 1 807$ Clean blower motor 0.75 0.5 605$ Clean Ash & Combustion Air Intake 0.08 0.05 614$ Check & replace gaskets 3 5 242$ Total Cost per Lifetime 2,469$ Straight-Line Average Cost per Yr.123$ ELECTRICITY Yrs. To Cost Cost per Lifetime Electricity 3/4 HP fan 113$ 1 2,253$ Straight-Line Average Cost per Yr.113$ O&M Cost per Yr per Boiler 656$ No. of Boilers 2 Subtotal 1,311$ Electricity -- pump 490$ Total Annual Biomass O&M (non-stoking)1,801$ 975,000 Biomass, 20% MC* (cord) 20.17$ 0.65$ 1865 Page 12 of 16 Opinion of Probable Cost Figure 7: Force Account Summary Site & Foundation Work $16,050 Biomass boiler building $62,447 Biomass heat system $133,640 End-user building integration $9,789 Miscellaneous $8,700 Overhead $24,215 Freight $37,036 CONSTRUCTION SUB-TOTAL $291,877 Design & Construction Admin $25,484 Construction Management $12,742 PROJECT SUB-TOTAL $330,103 Contingency @ 20%$66,021 Admin @ 4%$13,204 TOTAL PROJECT COST $409,328 Page 13 of 16 Figure 8: Force Account Detail ITEM QUAN UNIT UNIT MATL UNIT LAB LAB LABOR CONTR FREIGHT TOTAL UNIT TOTAL COST COST HRS HRS RATE COST COST COST COST WT WT(#) SITE & FOUNDATION WORK Site prep (layout, excavation, backfill, compaction, grading)1 lump $5,000 $5,000 0.00 0 Wood timbers -- 8" x 8" x 8' 100 ea $63.00 $6,300 0.50 50.00 $95 $4,750 $11,050 70.00 7000 BIOMASS BOILER BUILDING $0 8 x 8 x 20 shipping container 4 ea $3,000 $12,000 0.00 0.00 $95 $0 $12,000 2500 10000 Man-door w/ hardware 1 ea $780 $780 6.0 6.00 $95 $570 $1,350 75 75 Roof, Metal -- 3' x 10' Delta rib roofing 44 ea.$175 $7,700 1.00 44.00 $95 $4,180 $11,880 96 4224 Roof frame 4 lump $900 $3,600 18.00 72.00 $95 $6,840 $10,440 400 1600 Fasteners 2 lump $250 $500 0 0.00 $95 $0 $500 100 200 Wall insulation 35 ea $170 $5,950 1.5 52.50 $95 $4,988 $10,938 20 700 Roof insulation -- 8 - 12" batt 4 lump $195 $780 5.00 20.00 $95 $1,900 $2,680 96 384 Fire extinguisher 1 lump $250 $250 0.10 0.10 $95 $10 $260 5 5 Conex reinforcement 4 ea $1,200 $4,800 20.00 80.00 $95 $7,600 $12,400 3300 13200 BIOMASS HEAT SYSTEM Boiler -- GARN 2000 or equivalent 3 ea.$16,000 $48,000 16 48 $95 $4,560 $52,560 3600 10800 Pipe/Valves/Ftgs/Gauges 3 lump $5,000 $15,000 54 162 $100 $16,200 $31,200 800 2400 Circ pump 4 ea.$500 $2,000 4 16 $100 $1,600 $3,600 60 240 Plate HXR, ( 300 MBh @ 20F)2 ea.$2,500 $5,000 2 4 $100 $400 $5,400 250 500 Misc Strut & Pipe Hangers 3 lump $1,000 $3,000 20 60 $95 $5,700 $8,700 500 1500 Tank Insulation 3 lump $1,200 $3,600 3 9 $95 $855 $4,455 50 150 Stack -- 6" dia double wall UL listed + supporting infrastructure 3 lump $1,700 $5,100 4 12 $95 $1,140 $6,240 3.8 11 Ventilation & Combustion Air Intake 1 lump $1,200 $1,200 3 3 $95 $285 $1,485 50 50 BTU meter 0 ea.$2,500 $0 18 0 $95 $0 $0 0 0 Electrical 1 lump $10,000 $10,000 100 100 $100 $10,000 $20,000 750 750 $0 INTEGRATION $0 Arctic Pipe -- 2" PEX 60 lf $25 $1,500 0.27 16 $95 $1,539 $3,039 1 60 PEX accessories -- 60 1/ft $5 $300 0 0 $95 $0 $300 1 60 Pipe penetration exclosure 2 lump $750 $1,500 5 10 $95 $950 $2,450 200 400 Temp controls 1 lump $750 $750 8 8 $100 $800 $1,550 200 200 Electrical work 1 lump $1,250 $1,250 12 12 $100 $1,200 $2,450 200 200 MISCELLANEOUS Misc Hardware 1 lump $2,500 $2,500 0 0 $95 $0 $2,500 500 500 Misc Tools & Safety Gear 1 lump $1,500 $1,500 0 0 $95 $0 $1,500 1446 1446 Consumables, Gases, Etc.1 lump $2,000 $2,000 0 0 $95 $0 $2,000 1500 1500 Wood splitter 1 ea $2,700 $2,700 0 0 $95 $0 $2,700 657 657 OVERHEAD ROW Legal Work 0 lump $0 0 Rent Heavy Equip 1 lump $1,500 $1,500 0 Misc Tool Rent 1 lump $1,250 $1,250 0 Commission System & Training 20 hr 1 20 $90 $1,800 $1,800 0 Superintendent Overhd Off-Site 40 hr 1 40 $90 $3,600 $3,600 0 Superintendent Overhd On-Site 80 hr 1 80 $90 $7,200 $7,200 0 Crew Travel Time 10 hr 1 10 $90 $900 $900 0 Crew Airfares 2 trips $1,050 $2,100 $2,100 0 Crew Per Diem 48 mn.dy.$60 $2,865 $2,865 0 Housing Rent 2 mo.$1,500 $3,000 $3,000 0 FREIGHT 58,812 Ground Freight 10800 lb.$1.24 $13,392 Barge 58812 lb.$0.30 $17,644 Barge Freight Tool Mob & Demob 2 lump $1,500 $3,000 Misc Small Freight & Gold Streaks 1 lump $3,000 $3,000 CONSTRUCTION SUB-TOTAL $149,560 935 $89,566 $15,715 $37,036 $291,877 Engineering (Design & CCA)10 %$25,484 Construction Management 5 %$12,742 PROJECT SUB-TOTAL $149,560 $89,566 53,941$ $37,036 $330,103 Contingency 20 %$66,021 Admin Fee 4 %$13,204 CONSTRUCTION TOTAL $409,328 Page 14 of 16 Financial Analysis Financial Summary The project is considered financially unfeasible at this time.  B/C: n/a  Simple Payback Period: n/a  Net present value: ($527,801) Benefit/ Cost Model The following model was designed by University of Alaska Anchorage Institute of Social and Economic Research, for use by the Alaska Energy Authority. The model has been adapted to the project and completed according to the aforementioned assumptions. AEA B/C Model (adapted) Project Description Community Nearest Fuel Community Region RE Technology Project ID Applicant Name Project Title Category Results NPV Benefits ($141,971) NPV Capital Costs $385,830 B/C Ratio (0.37) NPV Net Benefit ($527,801) Performance Unit Value Displaced Petroleum Fuel gallons per year 8,500 Displaced Petroleum Fuel total lifetime gallons 170,000 Avoided CO2 tonnes per year 86 Avoided CO2 total lifetime tonnes 1,726 Proposed System Unit Value Capital Costs $$409,328 Project Start year 2015 Project Life years 20 Displaced Heat gallons displaced per year 8,500 Heating Capacity Btu/hr 975,000 Heating Capacity Factor %85% Parameters Unit Value Heating Fuel Premium $ per gallon Discount Rate % per year 3% Crude Oil $ per barrel Iditarod Area School District Grayling school_biomass Grayling Grayling Rural Biomass Page 15 of 16 Annual Savings (Costs)Units 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034 Project Capital Cost $ per year 409,328$ -$ -$ -$ -$ -$ -$ -$ -$ -$ -$ -$ -$ -$ -$ -$ -$ -$ -$ -$ Electric Savings (Costs)$ per year $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 Heating Saving (Costs)$ per year ($15,148)($14,822)($14,457)($14,049)($13,596)($13,094)($12,542)($11,935)($11,270)($10,545)($9,754)($8,895)($7,963)($6,954)($5,863)($4,685)($3,416)($2,051)($582)$994 Transportation Savings (Costs)$ per year $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 Total Savings (Costs)$ per year ($15,148)($14,822)($14,457)($14,049)($13,596)($13,094)($12,542)($11,935)($11,270)($10,545)($9,754)($8,895)($7,963)($6,954)($5,863)($4,685)($3,416)($2,051)($582)$994 Net Benefit $ per year ($424,475)($14,822)($14,457)($14,049)($13,596)($13,094)($12,542)($11,935)($11,270)($10,545)($9,754)($8,895)($7,963)($6,954)($5,863)($4,685)($3,416)($2,051)($582)$994 Heating Units 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034 Renewable Heat gal. disp./ yr.8,500 8,500 8,500 8,500 8,500 8,500 8,500 8,500 8,500 8,500 8,500 8,500 8,500 8,500 8,500 8,500 8,500 8,500 8,500 8,500 Renewable Heat O&M (non-stoking)$ per yr.1,801$ 1,828$ 1,856$ 1,883$ 1,912$ 1,940$ 1,969$ 1,999$ 2,029$ 2,059$ 2,090$ 2,122$ 2,153$ 2,186$ 2,219$ 2,252$ 2,286$ 2,320$ 2,355$ 2,390$ Renewable Heat -- Stoking $ per yr.12,537$ 12,726$ 12,916$ 13,110$ 13,307$ 13,506$ 13,709$ 13,915$ 14,123$ 14,335$ 14,550$ 14,768$ 14,990$ 15,215$ 15,443$ 15,675$ 15,910$ 16,149$ 16,391$ 16,637$ Renewable Fuel Use Qty (biomass)cords 85.8 85.8 85.8 85.8 85.8 85.8 85.8 85.8 85.8 85.8 85.8 85.8 85.8 85.8 85.8 85.8 85.8 85.8 85.8 85.8 Renewable Fuel Cost $ per unit 375$ 386$ 398$ 410$ 422$ 435$ 448$ 461$ 475$ 489$ 504$ 519$ 535$ 551$ 567$ 584$ 602$ 620$ 638$ 658$ Total Renewable Fuel Cost $ per yr.32,174$ 33,139$ 34,133$ 35,157$ 36,212$ 37,299$ 38,417$ 39,570$ 40,757$ 41,980$ 43,239$ 44,536$ 45,872$ 47,249$ 48,666$ 50,126$ 51,630$ 53,179$ 54,774$ 56,417$ Supplemental Fuel Qty (Oil)gal.1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 Fuel Cost $ per gal.3.69$ 3.87$ 4.05$ 4.25$ 4.45$ 4.66$ 4.89$ 5.12$ 5.37$ 5.63$ 5.90$ 6.18$ 6.48$ 6.79$ 7.11$ 7.45$ 7.81$ 8.19$ 8.58$ 8.99$ Supplemental Fuel Cost $ per yr.5,535$ 5,801$ 6,079$ 6,371$ 6,677$ 6,997$ 7,333$ 7,685$ 8,054$ 8,441$ 8,846$ 9,270$ 9,715$ 10,182$ 10,670$ 11,182$ 11,719$ 12,282$ 12,871$ 13,489$ Proposed Heat Cost $ per yr.52,048$ 53,494$ 54,984$ 56,522$ 58,107$ 59,742$ 61,429$ 63,169$ 64,963$ 66,815$ 68,725$ 70,697$ 72,731$ 74,831$ 76,998$ 79,235$ 81,545$ 83,929$ 86,391$ 88,933$ Fuel Use gal. per yr.10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 Fuel Cost $ per gal. 3.69$ 3.87$ 4.05$ 4.25$ 4.45$ 4.66$ 4.89$ 5.12$ 5.37$ 5.63$ 5.90$ 6.18$ 6.48$ 6.79$ 7.11$ 7.45$ 7.81$ 8.19$ 8.58$ 8.99$ Fuel Cost $ per yr.36,900$ 38,671$ 40,527$ 42,473$ 44,511$ 46,648$ 48,887$ 51,234$ 53,693$ 56,270$ 58,971$ 61,802$ 64,768$ 67,877$ 71,135$ 74,550$ 78,128$ 81,878$ 85,808$ 89,927$ Base Heating Cost $ per yr.36,900$ 38,671$ 40,527$ 42,473$ 44,511$ 46,648$ 48,887$ 51,234$ 53,693$ 56,270$ 58,971$ 61,802$ 64,768$ 67,877$ 71,135$ 74,550$ 78,128$ 81,878$ 85,808$ 89,927$ Proposed Base Page 16 of 16 Sensitivity Analysis Sensitivity analysis was also performed. All other variables remaining equal, the following fuel variables results in an economically pre-feasible project. Recommendations Biomass heat at the David Louis Memorial School “School” building is considered financially unfeasible at this time, largely due to the relatively low price of fuel oil that the District is able to negotiate. Additionally, the U.S. Army Corp of Engineers Recommended Building Elevation in Grayling adds significant expense to the estimated cost of the building structure. The project also had challenges with technical feasibility, because the existing heat system operates in a narrow temperature range, 180 / 160°F. Cordwood systems are not very effective when serving building heat systems that operate in a narrow temperature range. It is recommended that the District consider other ways of reducing energy costs, which may include energy management, retro-commissioning, energy efficiency upgrades, and other types of renewable energy. Appendix A—Biomass Technology B – Utility Receipts C – Site Control D – Site Photos Fuel Oil Price per Gal, Yr. 1 6.97$ Benefit / Cost 1.25 NPV Net Benefit $94,917 Variable Results A-1 Appendix A – Biomass Technology Although humans have used wood for heat for millennia, modern high-efficiency biomass boilers have only been in use for a few decades. Biomass boilers may use wood fuels such as cordwood, wood chips, or wood pellets, to heat commercial buildings. Biomass boiler projects depend on sustainable forest management, quality biomass fuel sourcing, processing, and storage, and reliable fuel handling. Biomass boilers frequently integrate with conventional hydronic heat systems, which use water to move heat from where it is produced to where it is needed. Small-scale biomass systems often incorporate a hot water storage tank, which promotes efficient combustion and improves the availability of biomass heat. To provide reliable heat, the biomass boiler, building heat distribution system, controls, and heat emitters must be properly matched. Sustainable Forest Management Wood fuel Processing & Storage Handling Combustion Thermal Storage Heat Distribution The Nature of Wood Fuels Composition All wood is made primarily of cellulose, hemi-cellulose, and lignin. It is about 50% Carbon, 44% Oxygen, and 6% Hydrogen. Theoretically, complete combustion (100% efficient) would result in only two products: carbon dioxide and water. In practice, biomass boilers range from about 77 -- 83% efficient. Wood that is not completely burned become carbon monoxide and hydrocarbons, often in the form of smoke and ash.1 Combustion Biomass fuel undergoes fascinating changes as it burns. Pyrolysis occurs at 500 – 600°F, in which organic gasses leave behind charcoal solids. Primary combustion is burning of charcoal solids.2 Secondary combustion is burning of organic gasses. Because about 60% of the heating value is contained in gasses, secondary combustion is essential to high efficiency wood burning. 1 Rick Curkeet, PE, Wood Combustion Basics, EPA Burnwise Workshop 2011, http://www.epa.gov/burnwise/workshop2011/WoodCombustion-Curkeet.pdf (June 19, 2014). 2 Curkeet, Rick. A-2 Emissions In wood burning, the primary emissions concern is particulate matter 2.5 microns or less in size (“PM 2.5”), which is hazardous to human health. Additionally, unburned wood signifies lost heat and potential creosote formation. Creosote formation results in higher fuel costs, shortens the life of the boiler, and increases other maintenance costs. Boiler manufacturers have certified emissions tests conducted according to the ASTM E2618-13 standard that document boiler efficiency. High efficiency wood boilers emit about 0.07 – 0.3 lbs of PM 10 per million BTU in test conditions. Boiler manufacturers specify operating conditions for the field. One important condition is wood fuel specifications, which include moisture content and fuel dimensions. Other important conditions for efficient operation include proper fuel storage, routine operations and maintenance, and system design (such as proper boiler sizing and incorporating a hot water storage tank). One valuable source of information for seasoning cordwood in Interior Alaska is available at the Cold Climate Housing Research Center’s (CCHRC) website.3 “Properly prepared and stored” cordwood can be dry enough to burn safely within six weeks during the summer. In regions other than the Interior, similar storage principles would apply, but recommended storage durations may be different. Below is a summary of how to properly prepare and store cordwood: Cut to stove length (two feet or shorter) Split the wood at least once Stack in a pile with air space between the pieces Store wood in a shed or cover only the top of the pile with a large piece of plywood or some waterproof tarp Allow sun and air to reach the sides of the wood pile to help dry the wood Season at least six weeks during the summer months If beginning after August 1st, wait to burn until the next summer When properly stored, more time is always better Figure 1: Excerpt from CCHRC's Cordwood Handling Brochure 3 http://www.cchrc.org/docs/best_practices/Cordwood_Handling_Brochure.pdf A-3 Wood Fueled Heating Systems Below are the characteristics of cordwood, wood chip, and wood pellet boiler systems. Advantages Disadvantages Cordwood Local wood resource Small size (less than 1 MMBTU) Simple to operate Higher labor costs, including hand- feeding the boiler, manual ash removal, and manual grate cleaning Labor is needed intermittently, so someone must be available “on site” Typically non-pressurized, which may require more frequent boiler chemical additions Pellets Can operate unattended, and automatically match heat load Scalable from small to large sizes (generally 100,000 btu – 1 MMBTU) Relatively small footprint Typically the most efficient biomass combustion Pellet fuel is typically not locally produced, and therefore depends on “imports” Shipping pellets is very costly; even a freight rate of $0.05 per lb. results in an additional cost of $100 per ton. Relatively expensive wood fuel Ash removal and grate cleaning may be automated or manual Chips Can operate unattended, and automatically match heat load Wood chips may be the lowest cost fuel Local wood resource may be available or produced Large projects achieve economies of scale Creates jobs in the woods and at the boiler plant Large systems are expensive Typically large sizes > 1,000,000 MMBTU Wood chip fuel can be diverse, which can make it difficult to meet fuel specifications. Screens and other devices can improve fuel quality. B-1 B – Utility Receipts C-1 C – Site Control D-1 Appendix D D-2 D-3 D-4 D-5 D-6 D-7 D-8 D-9 D-10