HomeMy WebLinkAboutKiseralik-Chikuminuk Hydro Presentation-to-House-Energy-and-Resources-Committee-Feb-2012 REF Grant 2195447Chikuminuk Lake Hydropower
House Energy & Resources
Committee Hearing
February 2012
Christine Klein, Calista EVP/COO
Elaine Brown, Nuvista Executive Director
1
Our Mission:
Improve the energy economics in Rural Alaska by creating energy generation
and transmission infrastructure to serve, connect and enable the region to
attain affordable, long term energy sustainability and self-sufficiency.
Nuvista Light & Electric Cooperative
Who Are We:
A non-profit corporation guided and
governed by twelve member Board
of Directors from across the region:
Association of Village Council
Presidents (AVCP), Yukon Kuskokwim
Health Corporation (YKHC), Regional
Housing Authority(AVCP-RHA),
Alaska Village Electric Coop (AVEC),
Middle Kuskokwim Electric,
Chaninnik Wind, Lower Yukon,
Calista Corporation
2
Current Situation in the
Yukon-Kuskokwim (Y-K) Delta:
•38+ Previous Energy Studies
document region need & options, and
indicate hydropower opportunities
•Region-wide Agreement previously
difficult due to large number villages,
remoteness, subsistence concerns,
and high costs
•Y-K Linking Infrastructure lacking
•6% Population Increase of last 10
years much higher than estimated,
and indicates growing energy needs
•Needed PCE subsidies —funding
better used in permanent solutions
(Wind turbine, Hydro, and Interties)
3
Y-K Delta Energy Costs
Diesel
•Primary home heating fuel cost
ranges $6.00 to $10.00/gallon 2011
•Expect $7.00 to $12.00 gallon 2012
•15-20% of family income 5 years ago
went to heating. Today its 60-75%
•Families choosing food vs. heating
Electricity
•Generated by over 40+ small village
owned diesel generators
•Home use < 50% Natl Average
•Cost = $0.58 to $1.05 kilowatt hour
•Escalating cost of energy
•PCE cannot keep up
4
Electrical Costs Already Far Exceed
the 25 year projections made in 2005
Village Power Costs
$0.00
$0.10
$0.20
$0.30
$0.40
$0.50
$0.60
$0.70
$0.80
2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025
Year $/KWH 15 MW Coal Plant at Bethel+Wind+SWGR, 5% Interest Continued Diesel Gen.+W.H.+ Wind
Mine Power Costs, Bethel+Mine+Wind, 5% Interest Bethel+Mine Gen. +Wind at 5% Interest, SWGR System, 5% Interest
Bethel+Mine Gen.+Wind and SWGR System, 0% Interest
Projected Village Power Costs
Average region cost
$0.825 per kwh
5
Where We’ve Been
•Over 38 Energy Studies, Data, and
Reports since ’75.
•> 41 largely independent aged diesel
power generator plants
•Village generators use >20 million
gallons of diesel year
•Transmission lines needed
•Coal and Hydropower listed
repeatedly as feasible options
•Energy costs escalating
•Wind, Bio-mass, Hydro, Diesel
•Some Coastal Villages proceed
w/wind generation but there’s
limited application in region, wind
studies continue to be done. Hooper Bay
6
Thank-You Legislators’ “2011”
Region: Calista/AVCP Southwest Alaska
Project: Chikuminuk Hydroelectric Alternative Energy
Scope: Initiate Licensing Activities, Environmental Studies,
Preliminary Engineering, & Investigations along with
holding Public Meetings within Regions
Request: $17,600,000
Funded: $10,000,000
7
•Region Public Meetings - hydropower site alternatives presented and
Chikuminuk was preferred alternative, positive, and selected – March 2011
•Executive Director & Program Manager nationwide recruitment and
interviews, with the selection of an Alaskan from region – August 2011
•Nuvista Team developing scopes, public meetings, agency coordination,
grant applications, technical assistance to region villages, overseeing
–100% Alaskan Hire, 75% Native hire, and Yupik speaking member
•Chikuminuk Stream gages reinstalled with USGS – Sept 2011
•Comprehensive region wide alternative energy plan underway
integrating past and future work to guide future development
•Region Intertie System plan developed and applying for project grants
•Engineering Request for Proposals and Consultants Selected October 2011
•Engineering Agreement with Hatch Engineering signed – January 2012
–Many Alaskan Subcontractors: companies from Fairbanks, Anchorage,
Wasilla and Bethel
–Team Kick
What We’ve Completed to date…
8
II. Transmission System Needed
Transmission Grid Build Out
Sequence with Wind Turbine
Generation Option
9
Chikuminuk Lake Hydro Schedule:
Licensing / Design / Construction
Continuous Activity
Intermittent Activity
TBD (based on design,
permits & weather)
10
Planned Activity Schedule for 2012
•February 2012
–Preliminary FERC Permit Application for Chikuminuk Lake Hydro project
–Request to FERC to use the Alternative Licensing Process (ALP)
–DNR Informational Meeting – Project & Team Introduction
•March 2012
–Agency Meetings Introducing Chikuminuk Project, discussing initial
study gap analysis results, and early start to field study plans.
–Wood Tikchik Advisory Council Meeting
–March 27-29 AVCP Annual Regional Housing Authority Conference in
Bethel to update the public on project status
•April 2012
–April 11-13 Yukon-Kuskokwim Health Corp Meetings update on project
–FERC Permit Preliminary Application Document (PAD) for Chikuminuk
•May/October 2012
–Joint Agency/Public Scoping Meetings for Chikuminuk Hydroelectric
–Preliminary Engineering and Dual Field Season Reconnaissance
11
Chikuminuk Project Phases:
Hydroelectric Energy Project Tasks Lead Schedule Funding Cost (millions)
1.Initiate Licensing Activities, field geo-
environmental studies, preliminary
engineering, investigations and holding
public meetings within the regions
Nuvista,
FERC
2011
2012
State
Private
$10.0M
2. Complete Licensing Application,
Environmental Studies, Engineering
Nuvista
AEA
2011
2015
State $7.6M
3. Transmission rights-of-ways surveys, and
land easements
Nuvista
DOI/BLM
2012-
2015
State
DOI
$7.83M
4. Final Designs, Permitting, Design
Modifications, and Bidding
Nuvista
AEA
2016
2018+
AIDEA, BIA
Bonds
$35.25M
5.Hydropower and transmission system
project Construction
TBD 2018
2022
Mix, DOE
Bonds
$391.7 M
(-10 to +25%)
Total Project Estimated Cost:
TBD 2012
2022
Mixture
$483M
12
Thank-You Legislators
Alternative Energy for Southwest Alaska
13