HomeMy WebLinkAboutAlaska Affordable Energy Strategy Report 01-19-2017-AALASKA AFFORDABLE ENERGY STRATEGY:
A Framework for Consumer Energy Sustainability Outside of the Railbelt
December 30, 2016
(Revised January 19, 2017)
www.akenergyauthority.org
December 30, 2016 Alaska Affordable Energy Strategy | 2
This report was made possible through a legislative mandate as articulated in SLA 2014 SB 138 requiring Alaska Energy
Authority (AEA) to investigate opportunities for delivering affordable energy infrastructure in non-Railbelt communities.
Principal Investigator: Neil McMahon, Energy Planning Manager, AEA
December 30, 2016 Alaska Affordable Energy Strategy | 3
TABLE OF CONTENTS
Introduction.............................................................................................................................................................. 4
Legislative Intent..................................................................................................................................................... 6
Concurrence with Existing Alaska State Energy Policy.............................................................................. 7
The Study Area......................................................................................................................................................... 8
Affordability.............................................................................................................................................................. 9
A Framework for Guiding Decisions................................................................................................................. 9
Methodology & Findings..................................................................................................................................10
Stakeholder Collaboration..........................................................................................................................10
Research Findings and Highlights.............................................................................................................11
Alaska Affordable Energy Strategy Recommendations...........................................................................15
Strengthen State Goals.................................................................................................................................15
The Four Pillars of the AkAES......................................................................................................................16
A. Identification of Cost-effective Projects..........................................................................................17
B. Financing Cost-effective Projects..................................................................................................... 20
C. Accountability and Sustainability..................................................................................................... 24
D. Funding State Energy Programs........................................................................................................ 28
Additional Opportunity for Consideration........................................................................................... 30
December 30, 2016 Alaska Affordable Energy Strategy | 4
INTRODUCTION
The Alaska Energy Authority (AEA) was tasked by the 28th Alaska Legislature to provide
recommendations to improve the affordability of energy in areas of the State not serviced by
the proposed natural gas pipeline (gasline). The Alaska Affordable Energy Strategy (AkAES) is
the result of this effort.
AkAES is a strategic plan to improve the methods by which the State works with non-
Railbelt communities and utilities to identify, evaluate, develop and maintain cost-effective
energy solutions. The strategy includes recommendations for policy, financing mechanisms,
strengthened regulation and other administrative tools. This report is a summary of the
AkAES strategy. A longer, complementary report titled AkAES Methodology, Findings, and
Recommendations goes into greater detail.
AkAES recommendations point to solutions with or
without the gasline. Many of these recommendations
can be implemented immediately.
Many Alaska communities face barriers to building
and maintaining energy infrastructure including: lack
of economies of scale, lack of access to a specialized
workforce, geographic isolation and lack of access to
funding. The State has tried to address these challenges with various programs and services
that have reduced consumer costs. Given the State’s current fiscal crisis, it is important to seek
efficiencies without compromising benefits to communities.
To this end, AEA investigated opportunities for delivering more affordable energy to non-
Railbelt communities, the efficacy of existing energy programs, as well as policy and/or
regulatory changes that have potential to contribute to more reasonably priced, safe, stable
and reliable consumer energy in non-Railbelt areas.
This project draws on decades of State research and experience, and also considers the current
economic conditions in Alaska.
The primary outcome of
AkAES is a streamlined,
data-driven approach geared
toward identifying, evaluating,
developing and maintaining
cost-effective energy solutions
in Alaska for the long term.
December 30, 2016 Alaska Affordable Energy Strategy | 5
The AkAES offers a streamlined, data-driven approach to identifying, evaluating, developing and
maintaining cost-effective energy solutions over the long term. The AkAES has the potential to
ease the necessary transition from a reliance on grants for energy infrastructure to a system in
which loans and private investment play a larger role. The AkAES recommendations are expected
to result in more sustainable energy infrastructure in the study area. AkAES recommendations
are also expected to bring statewide benefits in the form of cost savings. State money can be
saved through improved project selection, diversification of financing options and strengthening
accountability to maximize the full economic potential of energy projects and programs.
The recommendations and funding options below are organized into four categories.
Full descriptions follow on page 15.
A. Identification of cost-effective projects
• A1. Improve data collection and analysis and increase public access to the data
• A2. Clarify the State’s role in working with communities on energy project
identification, planning and financing
• A3. Establish energy codes for residential and non-residential buildings
B. Financing and funding of projects
• B1. Allow Bulk Fuel loan participants to purchase non-petroleum fuels
• B2. Create a “one-stop-shop” fund for communities that allows for segregated State,
federal and private grants and loans for energy projects
• B3. Create an energy loan program with refund provisions that reward project performance
• B4. Statutorily allow voluntary on-bill financing and Commercial Property Assessed
Clean Energy (C-PACE)
• B5. Modify Home Energy Rebate rules to expand access to residential efficiency services
and stabilize State funding for residential Weatherization Assistance Program
C. Accountability and sustainability
• C1. Strengthen business and financial management assistance for Power Cost
Equalization (PCE)-eligible utilities
• C2. Draw on the State’s partnerships with regional and statewide entities to more cost-
effectively provide needed assistance
• C3. Develop a cost-effective regulatory system to ensure rural electric utilities maintain
“fit, willing and able” status
December 30, 2016 Alaska Affordable Energy Strategy | 6
• C4. Require PCE-eligible, non-residential buildings of more than 5,000 square feet to have
an energy audit and perform cost-effective retrofits
• C5. Empower the Regulatory Commission of Alaska (RCA) to have siting authority over
generation and transmission for economically regulated utilities
• C6. Enact a one percent-per-year fuel reduction target for electric utilities until
cost-effective gains have been realized
As required by statute, the report also recommends potential funding sources, discussed in
more detail later in the report.
D. Funding State energy programs:
• D1. Use funds from the Alaska Affordable Energy Fund (AS 37.05.610) when they
become available
• D2. Pay for PCE administrative expenses and fund some energy programs with PCE funds
• D3. Establish a universal service charge to support community energy projects and
programs
• D4. Continue the PCE program and revive the Alaska Heating Assistance program
LEGISLATIVE INTENT
The legislative mandate for AkAES is contained in Sec. 75 of Chapter 14, SLA 14 (HCS CSSB
138(FIN) am H), authorizing legislation for the in-state gasline. The intent of the mandate was to
ensure an equitable distribution of gasline benefits for all Alaskans. Communities in proximity to
the gasline will potentially benefit from natural gas, while others will benefit from an affordable
energy plan funded by a portion of the State’s gasline revenues. The outcome, however, is a plan
that has value independent of the gasline revenue stream.
SB 138 instructs AEA to:
“develop a plan for developing infrastructure to deliver more affordable energy to areas of
the State that are not expected to have direct access to a North Slope natural gas pipeline”
December 30, 2016 Alaska Affordable Energy Strategy | 7
“identify ownership options, different energy sources… recommend the means for
generating, delivering, receiving and storing energy in the most cost-efficient manner”
and “may consider the development of regional energy systems that can receive and
store bulk fuel”
“[f]or those citizens for whom there is no economically viable infrastructure available,
recommend the means for directly underwriting the energy costs of the citizens to make
their energy costs more affordable”
“recommend a plan for funding the design, development, and construction of the
required infrastructure” including to “identify a source of rent, royalty, income or tax”
“provide the plan and suggested legislation for the design, development, construction
and financing of the required infrastructure to the Legislature before January 1, 2017”
CONCURRENCE WITH EXISTING ALASKA STATE ENERGY POLICY
Additionally, the legislation tasked AEA with considering the State’s current energy policy,
established in 2010 by House Bill 306. Several of the components of the 2010 energy policy
comport with the needs of the communities and are included in AkAES, including:
• Encouragement of statewide energy efficiency codes for new and renovated residential,
commercial and public buildings
• Decreasing public building energy consumption through conservation activities and
energy efficient technology
• Promotion and development of renewable and alternative energy resources
• Identification and assistance with development of the most cost-effective, long-term
sources of energy for each community statewide
• Creation and maintenance of a State fiscal regime allowing for permitting and regulatory
processes that encourage private sector development of the State’s energy resource
December 30, 2016 Alaska Affordable Energy Strategy | 8
• Streamlined regulatory processes and review that balance the economic costs of review
with the level of regulation necessary to protect the public interest
• Use one office or agency, as may be specified by law, to serve as a clearinghouse in
managing the State’s energy-related functions to avoid fragmentation and duplication
and to increase effectiveness
THE STUDY AREA
AEA worked with the Alaska Gasline Development Corporation
(AGDC) to define the study area as the entire State excluding
communities served by the Railbelt electric grid. The study
area includes more than 200 communities and approximately
25 percent of the State’s population
(165,000 Alaska residents).
With the exception of a few larger
Southeast communities, the AkAES study area is generally characterized by small, geographically
isolated communities that rely heavily on diesel fuel for both electric generation and heating.
The median community size is 300 residents and more than 90 percent of the communities
have populations of fewer than 2,000 people.
In 2016, the retail price for a gallon of heating oil ranged from a low of less than $1.50 per gallon
(due to local subsidies) to as high as $10 per gallon. The median cost for electricity without
factoring in the PCE subsidy was $0.62 per kilowatt-hour. Residents in the study area pay some
of the highest costs for energy in the nation.
To maintain current energy infrastructure in the AkAES study area, it is estimated that more than
$20 million for power generation and $13 million for bulk fuel storage in annual investment is
needed. The cost of maintaining transmission lines, alternative energy systems, building
efficiency and other components of the energy system would be additional annual costs.
December 30, 2016 Alaska Affordable Energy Strategy | 9
AFFORDABILITY
Affordability is impacted by the cost of the good or service being purchased, by the income
of the purchaser and by other goods and services competing for those same dollars. AEA
evaluated several potential methods for determining an appropriate, Alaska-specific
definition of affordability for this report. Possible definitions included bringing energy
costs in the study area in line with the Railbelt and setting a threshold for percentage of
household income spent on utility bills. All potential definitions were rejected either due
to the unreliability of community-level census data or because the definition would be
unachievable under any reasonable fiscal projection.
Given the State’s current and projected fiscal environment,
consumer energy costs are expected to increase in much
of the AkAES study area as less money is available for
grants and subsidies. The AkAES recommendations should
be compared against a future with less government funds,
not the past where State and federal grants were plentiful.
AEA uses the term “cost effective” for “affordable” as a
practical way of defining the primary goal of the project which is to reduce the cost of
energy in AkAES study area communities.
A FRAMEWORK FOR GUIDING DECISIONS
SB 138 requires that AEA “develop a plan for developing infrastructure to deliver more affordable
energy.” AEA understood “infrastructure” to include electric and heat generation resources,
both renewable and non-renewable, as well as analysis of energy efficiency improvements.
The AkAES includes recommendations for selecting, developing and managing these types of
energy infrastructure projects; it does not recommend a list of specific projects.
AEA did consider regional energy infrastructure projects. These options were ruled out for
insufficient cost-effectiveness, therefore there are no recommendations relating to specific
infrastructure or capital projects (e.g. liquefied natural gas delivery into rural Alaska communities).
The impact of the AkAES
recommendations should be
compared against a future with
less government funds, not the
past where State and federal
grants were plentiful.
December 30, 2016 Alaska Affordable Energy Strategy | 10
METHODOLOGY & FINDINGS
In developing the knowledge base, AEA placed a premium on learning from previous work and
collaborating with State and federal government agencies; local, regional and tribal entities;
utilities; and non-governmental organizations that would be best situated to understand the
causes and potential solutions to energy cost challenges within the study area.
The drivers of energy cost were identified and assessed in order to understand if and how
those factors could be changed. In particular, over 3,000 potential infrastructure projects were
evaluated using best available data and the Alaska Affordable Energy Model, a new community
energy evaluation tool developed as a part of the AkAES project.
To ease the transition to loan-based financing and reduce the development and operational
risks of infrastructure projects, non-infrastructure solutions such as improvements to financial,
management and technical capacity were investigated.
Further research was done to see how the findings could be used to build off of the successes
of current State energy programs.
STAKEHOLDER COLLABORATION
AEA worked with the following four groups during the course of the AkAES project.
I. Technical Advisory Committee: This group was comprised of the Alaska Center for
Energy and Power (ACEP), the Alaska Gasline Development Corporation (AGDC) and
the Institute for Social and Economic Research (ISER). The committee provided
guidance on the study methodology, assessment and evaluation of technology
solutions.
II. Advisory Group: This group was comprised of eight State entities, regional
organizations and utilities that provided guidance and feedback on work done by AEA
and contractors.
III. Contractors: Academic, private sector and federal entities were contracted to provide
specific technology, program and/or policy data collection and analysis. All reports
generated for the AkAES are available on the AEA website:
http://www.akenergyauthority.org/Policy-Planning/AffordableEnergy.
December 30, 2016 Alaska Affordable Energy Strategy | 11
IV. Alaska Energy Stakeholders: This group included dozens of local, regional, State and
federal government entities, NGOs, private companies and utilities that provided data,
expertise and review of work products developed over the course of the project.
RESEARCH FINDINGS AND HIGHLIGHTS
Below are five high-level findings from the AkAES study.
The Drivers of Energy Costs
Energy costs are driven by complex variables, some easier to influence than others. There are
two primary categories of cost drivers: the per-unit cost and the amount of energy consumption.
The retail rate for heating fuels include commodity cost, which for heating oil is determined
by an international market. Additional factors include the costs to transport and store the fuel.
Local markup, which is highly variable, is the last major driver of cost. Since many communities
purchase fuel one or two times per year, the retail price does not respond quickly to changes in
the commodity cost.
Electricity cost drivers are more complex. The retail rate is broadly divided into the fuel
costs and non-fuel costs. The fuel costs are determined by the unit cost of fuel (which is free
for renewables), the generation efficiency and line losses. Non-fuel costs include paying
for personnel, overhead and operations and maintenance. Non-fuel costs can be offset by
other types of utility sales, including heat sales and pole rentals. Utility size and structure
have a strong impact on the non-fuel costs. For the non-economically regulated utilities,
local pricing decisions can have a large positive or negative impact on price. A number of
communities and/or boroughs subsidize electricity prices, and other communities have
rates that are significantly above their reported expenses.
Decisions made in planning and program implementation by State and federal agencies can
also have a direct impact on the rates that consumers pay in communities.
The amount of energy consumed is influenced by: Alaska’s colder climates, varying levels of
building quality and consumer behaviors. State energy programs have been successful in cost-
effectively reducing energy consumption and federal efficiency standards have also contributed
to reduced per-customer residential sales.
December 30, 2016 Alaska Affordable Energy Strategy | 12
Infrastructure Improvements to Address Energy Cost Drivers
Strategies deployed to increase access to affordable energy must be tailored to the specific
resources, needs and capacity of the community and/or utility they are intended to benefit.
In order to analyze the cost-effectiveness of various infrastructure improvements in a given
community, AEA developed the Alaska Affordable Energy Model with the assistance of
Geographic Information Network of Alaska (GINA) to use the best available resource, generation
and cost data.
Demand-Side Energy Efficiency: Energy efficiency improvements in residential and non-
residential buildings was found to be cost effective across the study area, with an identified
comprehensive annual savings potential of more than 10 million gallons of heating oil.
Electricity: Opportunities for improvements in electricity generation, transmission and
distribution were found to be very site-specific. AEA found that renewable energy generation
opportunities for wind and hydro are limited by local resources and the economy of scale. The
most significant opportunity for cost savings in electricity generation and distribution is in
reducing distribution line losses.
Heat: Alternative sources of thermal energy, including biomass and air-source heat pumps
(ASHPs), were also investigated. Again, the geographic distribution and potential savings were
found to be very site-specific based on the availability of resources and the economy of scale.
Natural Gas: AEA found that liquefied natural gas (LNG) is not likely to be economically viable
in the AkAES study area given current market conditions.
Regional Bulk Fuel: Regional bulk fuel facilities were found to be potentially cost-effective in
two locations, one on the upper Kuskokwim and another on the upper Yukon.
Non-Infrastructure Improvements to Address Energy Cost Drivers
While infrastructure projects were initially the intended focus of the AkAES, the project found
instead that other, non-infrastructure improvements can have a significant role in reducing the
cost of energy in communities, especially in those without cost-effective infrastructure options.
December 30, 2016 Alaska Affordable Energy Strategy | 13
Utility Management: Utilities and communities have benefited from the direct savings of
economies of scale realized by consolidating utility management functions. Additional savings
can be realized through management decisions that impact the near-term performance and
long-term life expectancy of the energy infrastructure, e.g. operations and maintenance.
Operations and Maintenance: Research showed that
the expected performance and/or economic life of
energy projects is not always realized. This increases costs
to consumers and the State. Consumers pay higher rates
than are necessary. The State pays for more technical
assistance, capital costs and PCE subsidy. Energy projects
require appropriate, regular maintenance and adequate operation over the long term in order
to realize the project’s expected performance and economic life. Maintenance of the system
requires a certain level of technical, business, and financial capacity, the degree of which will
depend on the complexity of the system.
Informed Decision-Making: Risks exist across the entire life cycle of all projects. Decisions at all
stages influence the cost and sustainability of projects. The AkAES found that acknowledging
and mitigating risks—particularly through a staged approach to funding, clear pre-construction
study requirements and using qualified and experienced personnel—leads to better outcomes.
Use Loans to Leverage Public Funding and Encourage Private Sector Investment
Declining State revenue has increased the urgency of transitioning government support for
energy projects from grants to more loans, where State funding is used to incentivize and
supplement debt financing. In addition to the economic imperative, there are indications that
this shift can improve project selection, accountability and performance. Changing the system
which State agencies and communities have grown accustomed will require significant work
to address the more stringent financial, managerial and technical capacity requirements for
loan-based financing.
While it will not be possible to shift all State funding to loans—the per capita costs might be
too great for some communities—the AkAES found that many communities and utilities are in
a position to take on more debt for cost-effective projects.
Helping utilities meet standards
necessary for accessing loan
financing will reduce the need
for State capital funds.
December 30, 2016 Alaska Affordable Energy Strategy | 14
The AkAES found that communities need more flexibility in funding opportunities to address
their needs. Currently, many communities find themselves choosing and developing projects
based on what type of funding happens to be available rather than on the actual needs of
the community.
Simply increasing the availability of loans while reducing grant opportunities will not be
sufficient to catalyze a widely-adopted transition to loan-based funding. The State may
need to provide incentives, technical assistance and regulatory requirements to support
and encourage the transition to a loan-based project funding system. Helping utilities meet
standards necessary for loan financing will reduce the need for State capital funds.
Among barriers to private sector investment that the AkAES project revealed is a lack of
knowledge of investment opportunities in rural Alaska. Using the tools and resources
suggested for identifying cost-effective projects, the State can help identify opportunities—
through rigorous data collection and analysis—for private sector investors.
Private sector investors are generally more risk-averse than the State, meaning that they will
require a higher return on investment and/or be less willing to invest in communities lacking
strong financials and traditional collateral. Additional financial instruments, such as loan-loss
reserves, may be needed to absorb some of the risks for private sector investors.
Reducing Community need for Power Cost Equalization
With approximately $40 million in yearly subsidy, the Power Cost Equalization program is the
largest consistent source of energy funding in the AkAES study area. Opportunities presented
in the AkAES are expected to reduce costs to the PCE program.
Non-infrastructure strategies could potentially save millions of dollars per year for both
consumers and the PCE program. End-use efficiency, particularly in PCE-eligible, non-residential
community facilities, would save additional funds. This savings provides benefit to both
consumers and the State treasury.
December 30, 2016 Alaska Affordable Energy Strategy | 15
Potential Sources of Sustainable Energy Funding
Lack of sustainable program funding is a major barrier to the success of all current energy
programs, with the exception of PCE. Identifying “a source of rent, royalty, income or tax” was also
a requirement of the project’s enabling legislation. The AkAES identified a number of potential
sources of sustainable energy funding including existing endowments, future legislative funds,
removing existing tax exemptions and increasing existing regulatory charges.
Improving Collaborative Leadership for Community and Consumer Energy
The State’s current efforts to assist communities are spread over multiple agencies and rely on
interagency collaboration and coordination to provide assistance to communities. The AkAES
found that targeted State energy policy, combined with the designation of a State entity with
authority to consolidate and manage consumer energy programs, to the extent that is reasonable,
would create efficiencies by streamlining the delivery of energy programs and services.
ALASKA AFFORDABLE ENERGY STRATEGY RECOMMENDATIONS
STRENGTHEN STATE GOALS
Given the critical importance of sustainable community energy systems that are safe, stable
and reliable, it is recommended that the State energy goals be enhanced to include:
All communities will have safe, stable, reliable and affordable energy by 2030.
Barrier(s) addressed: Current State goals speak to increasing renewable energy, efficiency,
natural gas distribution, use of a loan program and that the State should remain a leader in
petroleum and natural gas production and become a leader in renewable and alternative
energy development. None of these goals speak to the development and maintenance of basic,
critical energy infrastructure such as diesel powerhouses.
December 30, 2016 Alaska Affordable Energy Strategy | 16
THE FOUR PILLARS OF THE AkAES
The AkAES proposes an evidence-based management
framework to guide decision-making. Additionally, each
recommendation aims to address barriers to achieving
affordable energy in the study area.
The AkAES recommendations are built on a foundation of collaboration, stakeholder
engagement and comprehensive research. Implementation of the recommendations requires
changes to statute, regulation and policy. The recommendations are organized into four
categories or pillars that support the aforementioned goal of delivering safe, reliable, stable
and affordable energy:
A. Identification of cost-effective projects
B. Financing cost-effective projects
C. Accountability and sustainability
D. Funding State energy programs
The solutions proposed by the AkAES all employ at least one of the following:
1) Direct financing (e.g. grants, loans, incentives)
2) Technical assistance (e.g. the collection and sharing of data, information, analysis,
evaluation, consultation)
3) Requirements (e.g. mandates, regulations, performance standards)
The following recommendations build off of the many successes of Alaska’s energy programs
within the study area.
Each individual recommendation would bring benefit if implemented, whether as stand-alone
actions or collectively as a suite of changes. The greatest degree of benefit, however, would
come from implementing all recommendations together.
Safe, Reliable, Stable &
Affordable Energy
A. IdentificationB. Project FinancingD. Funding ProgramsC. Accountability & SustainabilityCollaboration, stakeholder engagement &
comprehensive research
December 30, 2016 Alaska Affordable Energy Strategy | 17
Safe, Reliable, Stable &
Affordable Energy
A. IdentificationB. Financing ProjectsD. Funding ProgramsC. Accountability & SustainabilityCollaboration, stakeholder engagement &
comprehensive research
A. INDENTIFICATION OF COST-EFFECTIVE PROJECTS
A one-size-fits-all approach to energy does not work
for Alaska communities. Socioeconomic realities differ
greatly across the study area, as do barriers to long-
term, sustainable project development including access
to resources and capital, a trained and local workforce,
revenue, resource availability and generation capacity,
amongst others. Better community-level data are necessary
to make well-informed decisions about energy projects and
programs.
There are also forces outside of communities that create barriers to optimum project
identification and selection. Many energy programs are governed by a multitude of State and
federal agencies, and evaluation criteria for projects are not always consistent across programs.
To overcome these barriers, AkAES recommends the following:
A1. IMPROVE DATA COLLECTION AND ANALYSIS
1. Collect and create publicly accessible, community-level energy data for Alaska
communities that receive PCE or have a population greater than 20 people.
2. Collect and create publicly accessible data regarding State energy programs for the
purpose of improving their cost effectiveness.
3. Maintain an online analysis tool, the Alaska Affordable Energy Model, to provide
guidance regarding the cost effectiveness of energy infrastructure opportunities
in Alaska’s communities.
Benefit(s): High-quality energy data and analysis can help deliver savings by improving project
identification, risk management and program design.
Barrier(s) addressed: Communities and potential investors, both public and private, lack quality
data and data-driven decision support tools to identify and evaluate the cost effectiveness
December 30, 2016 Alaska Affordable Energy Strategy | 18
of potential infrastructure and non-infrastructure opportunities. Community energy data
is not systematically collected, analyzed and made available. When the risks associated with
community energy projects are not clearly understood, the results can increase costs and
stymie investment.
Connections to other recommendations: An energy data program, coordinated with the
State’s existing energy data initiatives, would collect and analyze data generated by the
implementation of other recommendations. The data program would help to identify projects
for financing (Recommendations B2 and B4) and create efficiency in assisting communities
(Recommendations A2, C1 and C2) through new data and analytic tools. Data would be collected
that could assist communities with meeting regulatory requirements (Recommendation C3).
A2. CLARIFY STATE’S ROLE IN WORKING WITH COMMUNITIES ON PROJECT
IDENTIFICATION, PLANNING AND FINANCING
This recommendation would establish a process for providing community assistance outside
of grant fund management. The State can designate a sole agency to work with communities
to identify, plan and secure financing for improvements to generation efficiency, lower line
losses, fuel storage, incorporation of renewable energy, residential and non-residential energy
efficiency and/or improvements to management, as well as operations and maintenance.
Although AEA performs this function through regulations in support of the organization’s
mission, there is no clear statutory language that mandates the State help communities reduce
their energy costs. This should be formalized as a core responsibility of the State energy office.
Benefit(s): Formalizing the State’s role in project selection can lead to reduced cost to
communities through improved project selection and significant savings to the State through
reduced PCE expenditures. Savings for participants in the Alaska Heating Assistance Program
are also possible.
Barrier(s) addressed: A clear process for communities to engage the State regarding energy
projects outside of grants and loans does not exist. Designation of a state agency for this
purpose creates accountability and continuity for communities seeking support.
December 30, 2016 Alaska Affordable Energy Strategy | 19
Connections to other recommendations: This recommendation would help utilities fulfill the
cost-effective fuel reduction target under Recommendation C6 and the efficiency requirement
outlined in Recommendation C4. State involvement early in project development can reduce
project risks and help projects access appropriate financing including the Community Energy
Fund for Alaska (Recommendation B2).
A3. ESTABLISH RESIDENTIAL AND NON-RESIDENTIAL BUILDING ENERGY
CODES FOR NEW CONSTRUCTION AND MAJOR RENOVATIONS
1. Consolidate 134 statutory references to building codes in one section of State statute.
2. Give authority for code administration to one or two agencies.
3. Authorize a code commission through a public regulation process to establish and
update building and energy codes.
Benefit(s): Building to a higher standard is cost effective and less expensive than retrofitting a
poorly built building later. There are direct savings to the Power Cost Equalization and Alaska
Heating Assistance programs as well as potential benefit to public health, safety and the
environment.
Barrier(s) addressed: Buildings consume the majority of energy in communities. New buildings
that are not built to a high standard have higher operational and lifetime costs. Currently,
building codes are referenced in more than 134 Alaska statutes with authority for enforcement
spread throughout six state agencies. Consolidation of these codes and agency responsibility
will create cost savings for the State and create clarity for communities and builders.
Connections to other recommendations: Building energy codes will reduce the need for some
services in the future, such as the Weatherization Assistance Program, other home energy
retrofit programs and PCE.
December 30, 2016 Alaska Affordable Energy Strategy | 20
Safe, Reliable, Stable &
Affordable Energy
A. IdentificationB. Financing ProjectsD. Funding ProgramsC. Accountability & SustainabilityCollaboration, stakeholder engagement &
comprehensive research
B. FINANCING COST-EFFECTIVE PROJECTS
State and federal grant funds are decreasing, and utilities
and communities will need to rely more heavily on loan
programs in the future. The energy project funding
landscape in Alaska is multifaceted and often in flux;
navigating it is a barrier for some communities. Small
communities that are not members of a larger utility
co-op and do not have traditional collateral often have
trouble accessing debt financing.
The recommendations that follow provide a mechanism to reduce loan transaction costs
for borrowers and lenders, match communities with appropriate funding entities and create
incentives for project performance.
B1. ALLOW BULK FUEL LOAN PARTICIPANTS TO PURCHASE
NON-PETROLEUM FUELS
• For example, cordwood, pellets and liquefied natural gas.
Benefit(s): This would extend the same financial risk reduction to communities that use
non-petroleum fuels as for petroleum fuels. This also removes a potential disincentive to
communities considering switching to non-petroleum fuels.
Barrier(s) addressed: Many energy infrastructure projects use non-petroleum fuels. There is
currently no State-funded loan that allows for the purchase of those fuels.
Connections to other recommendations: Alternative fuel sources may be identified through
mechanisms created by other recommendations; communities that currently rely on the bulk
fuel loan program would benefit from comparable financial risk reduction.
December 30, 2016 Alaska Affordable Energy Strategy | 21
B2. CREATE A ONE-STOP-SHOP FUND FOR COMMUNITIES THAT ALLOWS
FOR SEGREGATED STATE, FEDERAL AND PRIVATE GRANTS AND LOANS THAT
COULD BE BLENDED TO DEVELOP ENERGY PROJECTS
The Community Energy Fund for Alaska (CEFA):
• Can create cost efficiencies by creating a single portal to a variety of fund sources,
reducing lines of repetitive inquiry and overlap of efforts by multiple agencies
• Can provide access to public and private funding sources
• Be accessible by utilities, municipalities, boroughs, cities, tribes and non-residential
facility owners, to the extent allowed for by the original funding source
• Be available for generation, distribution, transmission and energy efficiency projects
• Would require that the project is a cost-effective strategy for meeting a community
energy need
NOTE: For utility-scale generation projects, the use of CEFA funds would require adherence to the
proposed utility management, financial and performance standards per Recommendation C3.
Benefit(s): This recommendation reduces the need for State grant funds and increases
involvement of non-State investors. The CEFA has potential to reduce transaction costs for
communities and investors. Existing State energy infrastructure grant and loan programs
could be consolidated under the CEFA to create cost efficiencies. CEFA fund requirements
would increase accountability through adherence to the proposed standards resulting from
Recommendation C3.
Barrier(s) addressed:
• Fewer State grant opportunities are available for energy projects and communities may
have difficulty identifying and securing alternative funding/financing sources.
• Funding sources are not always available for identified community needs.
• Transaction costs for projects in communities with small populations negatively impact
the economics of energy projects and create barriers to achieving a deal.
• The State does not have the needed funding. Enacting this recommendation would
allow communities to focus on identifying and developing the best project options
rather than pursue a myriad of funding options.
December 30, 2016 Alaska Affordable Energy Strategy | 22
Connections to other recommendations: All of the recommendations for project identification
could lead into this new fund. The proposed standards resulting from Recommendation C3
would help to reduce risk for State and other investors. The next recommendation, B3, is a
subset of this recommendation.
B3. CREATE A LOAN PROGRAM WITH REFUND PROVISIONS THAT REWARD
PROJECT PERFORMANCE
• The loan provisions, as a financing product available through the Community Energy
Fund for Alaska, will allow for partial annual reimbursements over the economic
life of the project to incentivize meeting performance and reporting objectives.
Benefit(s): The opportunity to receive a refund creates an incentive for communities to
maintain infrastructure, achieve energy project objectives and cost-effective performance
standards. The State will experience savings in reduced need for PCE, emergency technical
responses to repair equipment and capital grants. The increased performance and life of the
infrastructure will also reduce costs for consumers.
Barrier(s) addressed: It is difficult to ensure completion of the maintenance protocols needed
to deliver the expected performance and extend the life of energy infrastructure in many
communities. Without proper equipment maintenance, communities do not enjoy the full
economic value of energy infrastructure projects, increasing the cost of energy in that community
for consumers and the State.
Connections to other recommendations: This recommendation is a key financial product of
the Community Energy Fund for Alaska. It also directly ties in with the goals associated with
accountability and sustainability. The proposed enhanced business and financial assistance to
utilities (Recommendation C1) will ensure that utilities are able to meet performance standards.
B4. STATUTORILY ALLOW VOLUNTARY ON-BILL FINANCING AND C-PACE
Benefit(s): Voluntary programs, such as on-bill financing and Commercial Property Assessed
Clean Energy (C-PACE), allow for the financing of efficiency and renewable energy projects to
be bound to the property, removing uncertainty regarding length of ownership. C-PACE was
introduced in 2015 and is anticipated to be reintroduced by the Governor in 2017.
December 30, 2016 Alaska Affordable Energy Strategy | 23
Barrier(s) addressed: Building ownership length is variable and sometimes difficult to predict.
Individuals and organizations, therefore, may not recoup the energy efficiency or renewable energy
investments through lower energy bills. Commercial property owners want to minimize how
much debt is booked; C-PACE allows off-book debt financing of building-level energy projects.
C-PACE allows longer terms than traditional commercial loans, decreasing impact on cash flow and
increasing the potential scope of cost-effective projects.
Connections to other recommendations: The CEFA (Recommendation B2) could act as a funding
source for either on-bill financing or C-PACE. Either of these financing mechanisms could assist
large public facilities in financing the cost-effective retrofit required in Recommendation C4.
B5. STABILIZE THE STATE’S FUNDING FOR RESIDENTIAL EFFICIENCY PROGRAMS:
• Ensure a $10 million-per-year baseline for the Weatherization Assistance Program.
• Modify rules of the Home Energy Rebate (HER) program to expand residential efficiency
services. Develop income-based, tiered match requirements to better leverage State
investment in residential efficiency and allow participation of households whose
incomes are too high for the Weatherization Assistance Program but too low for the
Home Energy Rebate program as it is currently structured.
Benefit(s): The recommendation allows households above the Weatherization Assistance
Program maximum income limits to receive residential efficiency services. The new tiered
match approach effectively leverages greater private investment. Stabilizing funding for the
Weatherization Assistance Program secures a well-trained workforce and provides services to
those with the highest need.
Barrier(s) addressed: Funding uncertainty impacts the maintenance and capacity of energy
efficiency programs that serve consumers with the highest need. Existing income limits are
rigid, leaving many consumers without access to residential efficiency services. Smaller, rural
communities need more assistance to access services that allow participation in the HER program.
Connections to other recommendations: On-bill financing (Recommendation B4) could be a
way to assist HER participants with financing the match requirement.
December 30, 2016 Alaska Affordable Energy Strategy | 24
Safe, Reliable, Stable &
Affordable Energy
A. IdentificationB. Financing ProjectsD. Funding ProgramsC. Accountability & SustainabilityCollaboration, stakeholder engagement &
comprehensive research
C. ACCOUNTABILITY AND SUSTAINABILITY
The current system for delivering affordable energy,
at both the State and local levels, lacks the incentives
and requirements needed to create accountability and
sustainability. Many State programs are not required
to report ongoing performance of systems, and there
are often no incentives or disincentives for grantee
performance and reporting. The PCE program does
have two technical standards related to diesel efficiency
and levels of line loss, but there are no utility standards
related to operational efficiency, e.g. proper maintenance and proper financial management.
These factors can lead to consumers paying more than is necessary due to excessive line loss,
lower-than-expected generation, or higher-than-average administrative costs. Without grants,
consumers will pay even more for infrastructure if it is not properly maintained.
The State likewise ends up spending more on PCE, technical assistance and capital grants than
would be necessary if there was greater utility accountability.
Greater accountability will also create the conditions that will allow more communities and
utilities to be able to access non-State financing.
C1. STRENGTHEN BUSINESS AND FINANCIAL MANAGEMENT ASSISTANCE
FOR PCE-ELIGIBLE UTILITIES
Benefit(s): Millions of dollars of potential savings for consumers and the State through improved
management and financial practices are possible. Improved business practices will facilitate
access to non-State financing sources for many utilities.
Barrier(s) addressed: Analysis shows that some utilities underreport their eligible expenses to
PCE, thereby reducing their access to PCE subsidy, increasing financial risks and decreasing
potential access to non-State financing of energy projects.
December 30, 2016 Alaska Affordable Energy Strategy | 25
Connections to other recommendations: Recommendation C3 will identify communities in
need of business and financial assistance. The CEFA (Recommendation B2) would require
better business and financial management from participants.
C2. DRAW ON THE STATE’S PARTNERSHIPS WITH REGIONAL AND
STATEWIDE ENTITIES TO MORE COST-EFFECTIVELY PROVIDE
NEEDED ASSISTANCE
• Assistance could include: utility financials, record keeping and management, project
management, bulk fuel operations and maintenance, non-residential efficiency, etc.
Benefit(s): Increasing the economy of scale of management and technical services could unlock
millions of dollars of savings through improved utility operations. Regional entities are likely to
know details about a local energy provider and be quick to identify and respond to a need. This
recommendation would leverage AEA’s recent regional planning efforts.
Barrier(s) addressed: Many communities do not have adequate capacity or economy of scale to
cost-effectively manage projects and/or infrastructure.
Connections to other recommendations: This recommendation will help utilities meet the
standards proposed in Recommendation C3. A regional entity could act as a conduit of
CEFA funds to communities. Partnerships could also help with non-residential efficiency
(Recommendation C4) and utility fuel reduction strategies (Recommendation C6).
C3. DEVELOP A COST-EFFECTIVE REGULATORY SYSTEM TO ENSURE RURAL
ELECTRIC UTILITIES MAINTAIN “FIT, WILLING AND ABLE” STATUS
Benefits(s): This recommendation will ensure that initial utility standards are maintained
through the life of a project. Ensuring standards are met in an ongoing way is expected to
improve service and reduce costs to the community and State, and can help utilities access
non-State financing.
Barrier(s) addressed: There are no standards that require unregulated electric utilities to operate
in a way that provides safe, stable, reliable and affordable energy after they have received a
Certificate of Public Convenience and Necessity (CPCN).
December 30, 2016 Alaska Affordable Energy Strategy | 26
Connections to other recommendations: The data gathered from this recommendation will
feed into the State Energy Data program (Recommendation A1). The recommendation will
reduce risk for investors in the CEFA (Recommendation B2).
C4. REQUIRE PCE-ELIGIBLE, NON-RESIDENTIAL BULDINGS LARGER
THAN 5,000 SQUARE FEET TO HAVE AN ENERGY AUDIT AND PERFORM
COST-EFFECTIVE RETROFITS
• Public and/or community buildings greater than 5,000 square feet would be required
to perform energy retrofits if the retrofit would produce net savings within 10 years.
Benefit(s): Reducing energy consumption frees up funding for other community needs and
helps ensure that the State is not paying more than necessary to operate facilities.
Barrier(s) addressed: Many large community facilities are not energy efficient, increasing their
operating costs.
Connections to other recommendations: The Community Energy Fund for Alaska
(Recommendation B2) provides a financing mechanism for cost-effective retrofits. On-bill
financing and C-PACE (Recommendation B4) would also provide financing instruments. State
technical assistance (Recommendation A2) and/or regional organizations (Recommendation
C2) would help guide building owners through the process of auditing and implementing
efficiency measures.
C5. EMPOWER THE REGULATORY COMMISSION OF ALASKA (RCA) TO
HAVE SITING AUTHORITY OVER GENERATION AND TRANSMISSION FOR
ECONOMICALLY REGULATED UTILITIES
Benefit(s): This recommendation provides certainty that utility investments will be recovered
through rates. The recommendation also provides a measure of oversight and consumer
protection by reducing the risk of building unnecessary infrastructure that must be paid for
through increased rates.
Barrier(s) addressed: Currently, the RCA makes a determination on the eligibility of energy
infrastructure after it has been built. Empowering the RCA with siting authority would require
December 30, 2016 Alaska Affordable Energy Strategy | 27
that the determination of eligibility is made prior to construction. The possibility that the RCA
might not allow a utility to recover costs from a new generation plant is a source of uncertainty
for energy system investors.
Connections to other recommendations: The recommendation could provide more certainty
for investors participating in the CEFA (Recommendation B2).
C6: ENACT A ONE PERCENT-PER-YEAR FUEL REDUCTION TARGET FOR ELECTRIC
UTILITIES UNTIL COST-EFFECTIVE EFFICIENCY GAINS HAVE BEEN REALIZED
• Measurement of reduction will be based on a percentage of fuel for generation per
residential customer to avoid penalizing utilities with load growth.
Benefit(s): Cost-effective efficiency gains will reduce costs for consumers. The State will
realize savings through reduced PCE subsidies. The recommendation will increase the
market for energy private sector services to utilities and provides flexibility as savings can
be achieved through diesel efficiency, line loss reduction, renewable energy installation
and energy efficiency improvements.
Barrier(s) addressed: The State does not require utilities to find cost savings through efficiency
and renewable projects. There is no requirement for continued improvement.
Connections to other recommendations: This recommendation helps spur the involvement
of utilities for all other recommendations. Technical assistance to help utilities identify and
implement savings measures could be provided by State (Recommendation A2) and regional
(Recommendations C2) entities. The Community Energy Fund for Alaska (Recommendation
B2) provides a financing mechanism for cost-effective retrofits. On-bill financing and C-PACE
(Recommendation B4) could also be effective financing instruments.
December 30, 2016 Alaska Affordable Energy Strategy | 28
Safe, Reliable, Stable &
Affordable Energy
A. IdentificationB. Financing ProjectsD. Funding ProgramsC. Accountability & SustainabilityCollaboration, stakeholder engagement &
comprehensive research
D. FUNDING STATE ENERGY PROGRAMS
Identifying “a source of rent, royalty, income or tax” is
a requirement of the project’s enabling legislation. In
the past decade, the State has spent over $1 billion on
energy projects. The needs met by those appropriations
will still exist in the future. Although the previous
recommendations are expected to provide savings to the
State, funding will be needed to meet community needs
and bring more affordable energy to communities.
D1. USE THE ALASKA AFFORDABLE ENERGY FUND (AS 37.05.610)
WHEN IT BECOMES AVAILABLE
• Chapter 14, SLA 14 created a special account in the general fund to provide a source
from which the Legislature may appropriate money to develop infrastructure to
deliver energy to areas of the State that are not expected to have, or do not have,
direct access to a pipeline transporting natural gas from the North Slope.
• AS 37.05.610 suggests that up to 20 percent of the revenue from the State’s royalty gas
from an Alaska LNG project (after the payment of rents and royalties to the Permanent
Fund) may be placed in this account to help with energy delivery in the AkAES target area.
Benefit(s): The Alaska Affordable Energy Fund could provide a sustainable source of funding.
Barrier(s) addressed: Sustainable energy funding is not currently available.
Connections to other recommendations: The Alaska Affordable Energy Fund could provide
funding to expand the scope of services supplied by energy programs and be used as a source
of funding for the CEFA in Recommendation B2.
December 30, 2016 Alaska Affordable Energy Strategy | 29
D2. PROVIDE FOR PAYMENT OF PCE ADMINISTRATIVE EXPENSES
AND FUND ENERGY PROGRAMS WITH PCE FUNDS.
Benefit(s): This would reduce the need for undesignated general funds for State energy
programs.
Barrier(s) addressed: There are near-term funding issues for State energy programs.
Connections to other recommendations: Shifting some of the current burden to the PCE
Endowment would allow for near-term implementation of many recommendations.
D3. TO SUPPORT COMMUNITY ENERGY PROJECTS AND PROGRAMS,
ESTABLISH A UNIVERSAL SERVICE CHARGE
• Remove the current exemption for heating oil from the State fuel tax. Develop
equivalent charges for natural gas and electricity.
Benefit(s): The heating oil charge will require removal of a current exemption, and the other
charges would create parity among the major energy sources. Collection would be at the local
utility or retailer in communities within the study area. This would also allow access to currently
unavailable data on heating oil to better understand community energy consumption.
Barrier(s) addressed: A fair, equitable and sustainable way to fund energy programs is needed.
Previous energy policy reports have identified per-unit energy surcharges as a means by which
other states generate receipts to fund energy-related programs.
Connections to other recommendations: A sustainable fund source will allow for greater benefit
to Alaska’s energy consumers and a source of funding for the CEFA in Recommendation B2 and
Weatherization and Home Energy Rebate programs (Recommendation B5).
D4. CONTINUE THE POWER COST EQUALIZATION & ALASKA HEATING
ASSISTANCE PROGRAMS
Benefit(s): The Power Cost Equalization and Alaska Heating Assistance Programs are known
programs that help underwrite the cost of energy in the AkAES target area.
December 30, 2016 Alaska Affordable Energy Strategy | 30
Barrier(s) addressed: For those communities without access to cost-effective infrastructure, AEA
was instructed by the legislation to identify a way to directly underwrite the cost of energy.
Connections to other recommendations: PCE is considered by some investors as a secure
revenue source that reduces their risk of investing in communities.
ADDITIONAL OPPORTUNITY FOR CONSIDERATION:
CONSIDER GIVING A STATE ENTITY THE AUTHORITY TO CONSOLIDATE AND
MANAGE STATE CONSUMER ENERGY PROGRAMS
Benefit(s): A State entity with the authority to consolidate and manage consumer energy, to
the extent that it is reasonable, would increase efficiency of delivering State energy programs
to communities.
Barrier(s) addressed: Implementation of the previous recommendations may spread State
energy programs over a half-dozen agencies. This would be further complicated by institutional
gaps and competing agency mandates. Developing a coordinated and strategic plan to best
assist communities becomes problematic.
Connections to other recommendations: The State entity would coordinate almost all other
aspects of these recommendations, although the RCA would remain independent.