Loading...
HomeMy WebLinkAboutKlawock_Craig_Senior_Prefeasibility_Study_Final 2014High Efficiency Low Emission Wood Fired Heating System Pre-Feasibility Report September 2, 2014    Version: Final  WES Energy & Environment, LLC 902 Market Street • Meadville, PA  16335  (814) 337‐8223    Prepared for:       Tlingit‐Haida Regional Housing Authority  Klawock Senior Center & Craig Senior Center    In Partnership with :  Fairbanks Economic Development CorporaƟon  Alaska Wood Energy Development Task  Group  Prepared By:  Biomass Prefeasibility Report Date: September 2, 2014 Tlingit‐Haida Regional Housing Authority   FINAL Prince of Wales Island, Alaska    WES Energy & Environment    Table of Contents 1.0 Executive Summary .............................................................................................................. 1  2.0 Existing Fuel Usage & Heating System ................................................................................. 3  2.1 Klawock Senior Center ..................................................................................................... 3  2.2 Craig Senior Center........................................................................................................... 5  3.0 Forest Resource and Fuel Availability .................................................................................. 7  4.0 Proposed Biomass System Options ..................................................................................... 8  4.1 Klawock Senior Center Biomass System Options ............................................................. 8  4.1.1 Option 1a : 160,000 Btu/hr Wood Pellet System ..................................................... 9  4.1.2 Option 1b : 100,000 Btu/hr Cord Wood System ..................................................... 10  4.2 Craig Senior Center Biomass System Options ................................................................ 12  4.2.1 Option 2a : 110,000 Btu/hr Wood Pellet System ................................................... 13  4.2.2 Option 2b : 100,000 Btu/hr Cord Wood System ..................................................... 14  5.0 Benefit/Cost Analysis ......................................................................................................... 16  6.0 Conclusions & Recommendations ..................................................................................... 19  7.0 General Biomass Technology Information ........................................................................ 21  Appendix A – Conceptual Drawings  Appendix B – Capital Cost Estimates   Appendix C – 20 Year Financing at 4% APR Cash Flow Analysis  Appendix D ‐ Sensitivity Analysis of Annual Savings to Oil and Biomass Prices             Biomass Prefeasibility Report Date: September 2, 2014 Tlingit‐Haida Regional Housing Authority   FINAL Prince of Wales Island, Alaska    WES Energy & Environment  Page 1 of 24  1.0 EXECUTIVE SUMMARY This preliminary feasibility study evaluates options for the Tlingit‐Haida Regional Housing  Authority to utilize high efficiency low emission wood fired technologies at the Craig Senior  Center and the Klawock Senior Center located on Prince of Wales Island, Alaska.  Installation of  a wood fired heating system would present the Tlingit‐Haida Regional Housing Authority with  the opportunity to reduce operating costs, utilize a renewable fuel for heating, and keep fuel  expenditures within the regional economy.    The two centers are located 7 miles away from each other and are each evaluated for  independent wood fired heating systems.  Figure 1 shows an aerial picture of the Klawock  Senior Center located in Klawock, Alaska.    Figure 1 – Aerial View of the Klawock Senior Center  Image source: Bing Maps        Biomass Prefeasibility Report Date: September 2, 2014 Tlingit‐Haida Regional Housing Authority   FINAL Prince of Wales Island, Alaska    WES Energy & Environment  Page 2 of 24  Figure 2 shows an aerial picture of the Craig Senior Center located in Craig, Alaska.    Figure 2 – Aerial View of the Craig Senior Center  Image source: Google Earth    Both buildings utilize #1 fuel oil fired boiler plants for space heating and domestic hot water  heating.  Two biomass boiler technologies including wood pellet and split cord wood systems  were considered for each facility.  A summary of the costs and benefits for each option are  listed in Table ES1.              Biomass Prefeasibility Report Date: September 2, 2014 Tlingit‐Haida Regional Housing Authority   FINAL Prince of Wales Island, Alaska    WES Energy & Environment  Page 3 of 24    Table ES1 – Cost and Benefit Summary  Option  Estimated  Capital  Cost  1st Year Net  Annual Operating  Savings  Simple  Payback,  Years  20 Year Net  Present Value  20 Year B/C  Ratio  1a – Klawock Senior Center Wood  Pellet System $102,275 $4,168 24.5 (10,626) 0.90   1b – Klawock Senior Center Cord  Wood System $97,405 $6,500 15.0 37,842  1.39   2a – Craig Senior Center Wood  Pellet System $131,497 $1,601 82.2 (93,983) 0.29   2b – Craig Senior Center Cord Wood  System $103,667 $3,182 32.6 (36,461) 0.65    Notes:  1 – Net Annual Operating Savings include costs for wood fuel, supplemental fossil fuel, and operation &  maintenance (O&M) costs.  2 – 20 Year Net Present Value takes the present value of the operating savings for each year using a discount rate  of 3.0% as published in the “Energy Price Indices and Discount Factors for Life‐Cycle Cost Analysis ‐2013” and the  initial capital outlay of the total project cost.   A value greater than zero means that savings are greater than  expenses over 20 years in the value of today’s dollars.  3 – 20 Year Benefit/Cost (B/C) Ratio is calculated by dividing the present value of net annual operating savings  over a 20 year period with a discount rate of 3.0% by the Estimated Capital Cost. A value greater than 1 means the  benefits exceed the costs over a 20 year period.  2.0 EXISTING FUEL USAGE & HEATING SYSTEM The Craig and Klawock Senior Centers both use #1 fuel oil fired heating systems.  This section  gives an overview of the fuel use and descriptions of the heating systems for each facility.  2.1 KLAWOCK SENIOR CENTER The Klawock Senior Center is a 24,980 ft2 facility housing approximately 30 residents and staff.   The facility used approximately 5,000 gallons of #1 fuel oil annually for space heating and  domestic hot water heating.  Annual expenditures are approximately $20,650 at the current  fuel price of $4.13 per gallon.  An above ground 1,100 gallon fuel oil tank is used for onsite  storage.  The boiler room contains two model WTGO‐7 Weil McLain hot water boilers firing on #1 fuel oil  and rated at 210,000 Btu/hr output and 50 psig.  The boilers were installed in 2008 and are in  excellent condition.  The hot water heating distribution system is a primary‐secondary piping  system with individual zone pumps distributing water throughout the building. Baseboard fin  tube radiant heaters provide space heating for rooms.  A makeup air handling unit with a hot  water coil is used for the kitchen and common area.   A digital control system is installed by  Delta Controls, however there is no way to interface with the control system without bringing  in a service technician with a laptop and appropriate software.  Domestic hot water is heated  indirectly using the heating boilers and stored in two 120 gallon HTP Superstor tanks.  There is  potential room in the existing boiler room to locate hot water thermal storage tanks and one  wood fired boiler.    Biomass Prefeasibility Report Date: September 2, 2014 Tlingit‐Haida Regional Housing Authority   FINAL Prince of Wales Island, Alaska    WES Energy & Environment  Page 4 of 24  Fuel deliveries for calendar year (CY) 2013 are used for the purposes of load modeling and  boiler sizing in this memorandum.  The heating degree days for CY 2013 were fairly close to the  30 year average for the region.  Thus, CY 2013 weather data from Klawock, Alaska is used with  the 5,000 gallon annual fuel oil use for the purposes of load modeling and boiler sizing in this  study.  Figure 2 shows how the daily average heating demand for the Klawock Senior Center  would be expected to vary over the course of a year.  During a 24‐hr period, the actual load will  vary above and below this average value.  Peak loads are estimated at 130% of the average  load.  Peak loads would be experienced for short durations over a 24 hour period.    Figure 3 – Klawock Senior Center Estimated Average Daily Heating Demand for CY 2013  Note: The daily average heating demand model is based on local weather data and annual fuel usage provided  by the Tlingit‐Haida Regional Housing Authority. The model assumes that each person uses 20 gallons of  domestic hot water per day for bathing, cooking, laundry, and hand washing.  Actual demand would fluctuate  above and below the average heating demand values shown over a 24‐hr period.  The peak demand is estimated  as 130% of the average demand and would only be experienced for short durations over a 24 hour period.    A load duration curve was developed using the daily average heating demand curves.  Load  duration curves sort the daily average heating demand over the course of a year from highest  to lowest and plot it over the number of days to show the annual range of facility heating  demand. Figure 4 shows the estimated load duration curve for CY 2013.  0.00 0.05 0.10 0.15 0.20 0.25 Heating Demand (mmBtu/hr)Estimated Daily Average Heating Demand Estimated Daily Peak Heating Demand Biomass Prefeasibility Report Date: September 2, 2014 Tlingit‐Haida Regional Housing Authority   FINAL Prince of Wales Island, Alaska    WES Energy & Environment  Page 5 of 24    Figure 4 – Klawock Senior Center Estimated Load Duration Curve for CY 2013  Note: The daily average heating demand model is based on local weather data and annual fuel usage provided  by the Tlingit‐Haida Regional Housing Authority.  The model assumes that each person uses 20 gallons per day of  domestic hot water. Actual demand would fluctuate above and below the daily average heating demand values  shown over a 24‐hr period.  The peak demand is estimated as 130% of the average demand and would only be  experienced for short durations over a 24 hour period.  2.2 CRAIG SENIOR CENTER The Craig Senior Center is a 5,400 ft2 facility housing 10 residents.  The facility used  approximately 3,000 gallons of #1 fuel oil annually for space heating and domestic hot water  heating.  Annual expenditures are approximately $12,390 at the current fuel price of $4.13 per  gallon.  An above ground 1,000 gallon fuel oil tank is used for onsite storage.  The boiler room contains two model P‐WGO‐6 Weil McLain hot water boilers firing on #1 fuel  oil and rated at 184,000 Btu/hr output and 50 psig.  The boilers were installed in ~2004 and are  in good condition.  The vent piping shows signs of corrosion from condensation in the flue gas.   Return water temperatures should not be below 140°F to the boiler to prevent condensation.   This can be accomplished by controlling water distribution temperatures or through the use of  a boiler protection valve.  The hot water heating distribution system is a primary‐secondary piping system with individual  zone pumps distributing water throughout the building. Baseboard fin tube heaters provide  0.00 0.05 0.10 0.15 0.20 0.25 11325374961738597109121133145157169181193205217229241253265277289301313325337349361Heating Demand (mmBtu/hr)Date Estimated Daily Average Heating Demand Estimated Daily Peak Heating Demand Biomass Prefeasibility Report Date: September 2, 2014 Tlingit‐Haida Regional Housing Authority   FINAL Prince of Wales Island, Alaska    WES Energy & Environment  Page 6 of 24  space heating for rooms.  Thermostats in each room and control valves on the fin tube heaters  are the only control for the system.   Domestic hot water is heated indirectly using the heating  boilers and stored in a Crown Mega‐Stor tank.  There is no room in the existing boiler room to  locate a wood fired boiler system or thermal storage tanks.  Additionally, space constraints  around of the building could provide a challenge for siting a system and onsite fuel storage.  Fuel deliveries for calendar year (CY) 2013 are used for the purposes of load modeling and  boiler sizing in this memorandum.  The heating degree days for CY 2013 were fairly close to 30  year average for the region.  Thus, CY 2013 weather data from Klawock, Alaska is used with the  3,000 gallon annual fuel oil use for the purposes of load modeling and boiler sizing in this study.   Figure 2 shows how the daily average heating demand for the Craig Senior Center would be  expected to vary over the course of a year.  During a 24‐hr period, the actual load will vary  above and below this average value.  Peak loads are estimated at 130% of the average load.   Peak loads would be experienced for short durations over a 24 hour period.    Figure 5 – Craig Senior Center Estimated Average Daily Heating Demand for CY 2013  Note: The daily average heating demand model is based on local weather data and annual fuel usage provided  by the Tlingit‐Haida Regional Housing Authority.  Actual demand would fluctuate above and below the average  heating demand values shown over a 24‐hr period.  The peak demand is estimated as 130% of the average  demand and would only be experienced for short durations over a 24 hour period.    0.00 0.02 0.04 0.06 0.08 0.10 0.12 0.14 0.16 Heating Demand (mmBtu/hr)Estimated Daily Average Heating Demand Estimated Daily Peak Heating Demand Biomass Prefeasibility Report Date: September 2, 2014 Tlingit‐Haida Regional Housing Authority   FINAL Prince of Wales Island, Alaska    WES Energy & Environment  Page 7 of 24  A load duration curve was developed using the daily average heating demand curves.  Load  duration curves sort the daily average heating demand over the course of a year from highest  to lowest and plot it over the number of days to show the annual range of facility heating  demand. Figure 4 shows the estimated load duration curve for CY 2013.    Figure 6 – Craig Senior Center Estimated Load Duration Curve for CY 2013  Note: The daily average heating demand model is based on local weather data and annual fuel usage provided  by the Tlingit‐Haida Regional Housing Authority.  Actual demand would fluctuate above and below the daily  average heating demand values shown over a 24‐hr period.  The peak demand is estimated as 130% of the  average demand and would only be experienced for short durations over a 24 hour period.  3.0 FOREST RESOURCE AND FUEL AVAILABILITY Prince of Wales Island is heavily forested with the majority of the land owned by the US Forest  Service and smaller tracts owned by State and private owners.  Federal resources on the island  are managed by the Tongass Land Management Plan. The most recent version was adopted in  2008.    Potential fuel suppliers were contacted for pricing and availability of biomass fuel.  Table 1 lists  the companies contacted, location, contact information, and fuels available.  Table 1 – Contacted Fuel Supplier’s  0.00 0.02 0.04 0.06 0.08 0.10 0.12 0.14 0.16 11325374961738597109121133145157169181193205217229241253265277289301313325337349361Heating Demand (mmBtu/hr)Date Estimated Daily Average Heating Demand Estimated Daily Peak Heating Demand Biomass Prefeasibility Report Date: September 2, 2014 Tlingit‐Haida Regional Housing Authority   FINAL Prince of Wales Island, Alaska    WES Energy & Environment  Page 8 of 24  Company Location Phone Fuels  Welcome Inn B&B Thorne Bay 907‐828‐3950  Palletized Split Cordwood  Viking Lumber Klawock 907‐755‐8880 Dry wood chips, Dry Sawdust, Wet Wood  Chips, Compressed Bricks  Tongass Forest Enterprises Ketchikan 907‐617‐4542 Wood Pellets    The biomass fuels considered for evaluation in this report are wood pellets and split cord wood.   Fuel prices used for evaluation are $330 per ton for wood pellets and $250 per 4’ x 4’ x 8’ cord.   Table 2 summarizes the available fuels for heating as well as their cost per mmBtu output  comparison.  Table 2 – Fuel Pricing and Cost per mmBtu  Fuel, Unit Cost per  Unit  Input Heating  Value,  mmBtu per  Unit  Estimated  Boiler  Efficiency  Boiler Output  Heating Value,  mmBtu/Unit  Boiler Output  Heating Cost,  $/mmBtu  Dry Cord Wood, Cord $250.00 18.1 70% 12.67 $19.73   Wood Pellets, Ton $330.00 15.2 80% 12.16 $27.14   #1 Fuel Oil, Gallon $4.13 0.134 80% 0.1072 $38.53   Note:  1 ‐ Assumes 20% moisture content wet basis for cord wood and 18.1 mmBtu per 4’ x 4’ x 8’ cord of Sitka Spruce.1  2 ‐ Input heating value assumes 8% moisture content wet basis for wood pellets with an average High Heating  Value of 8,255 Btu/lb of bone dry wood based on a mixture of Sitka Spruce (8,100 Btu/lb) and Western Hemlock  (8,410 Btu/lb)2.  4.0 PROPOSED BIOMASS SYSTEM OPTIONS Options for using high efficiency low emission biomass systems were evaluated for heating the  Klawock and Craig Senior Centers.  The Klawock Senior Center has space to fit one boiler firing  on cord wood or wood pellets and hot water thermal storage in the existing boiler room.  The  Craig Senior Center does not have any additional space available and would need to locate the  new boiler and thermal storage outside in a shed style building or container.  This section  described the proposed systems in detail.  4.1 KLAWOCK SENIOR CENTER BIOMASS SYSTEM OPTIONS Two high efficiency low emission biomass fired boiler systems are evaluated for  interconnection with the existing heating system at the Klawock Senior Center.  Option 1a  considers a boiler system that would fire on wood pellets.  Option 1b considers a boiler system  that would fire on cord wood.                                                            1 http://www.alaskawoodheating.com/energy_content.php  2 Avery, Robert B., Funck, James W., & Wilson, Pamela L. (2010). Fuelwood Characteristics of Northwestern Conifers  and Hardwoods (updated). Portland, Or.: U.S. Department of Agriculture, Forest Service, Pacific Northwest  Research Station.  Biomass Prefeasibility Report Date: September 2, 2014 Tlingit‐Haida Regional Housing Authority   FINAL Prince of Wales Island, Alaska    WES Energy & Environment  Page 9 of 24  4.1.1 Option 1a : 160,000 Btu/hr Wood Pellet System One advanced combustion wood pellet boiler sized at approximately 0.16 mmBtu/hr of heat  output would be combined with approximately 200 gallons of thermal storage to efficiently  meet the range of heating needs.  The rated operating range of the system would be from  ~0.05 to ~0.16 mmBtu/hr with thermal storage allowing short term peaks to be met.  The hot  water thermal storage would be heated to a preset temperature (typically 195°F or higher) that  is higher than distributed for building heat.  The thermal storage tank(s) would use a 3‐way  mixing valve to blend hot water in the tank with colder return water from the senior center to  maintain a range of supply water temperatures (160°F – 190°F) determined by an outside air  temperature reset schedule.  The storage would allow the system to meet a 1‐hr peak of ~0.18 mmBtu/hr and a 15 minute  peak of ~0.26 mmBtu/hr.  The storage would also allow the boiler to operate efficiently to  provide domestic hot water heating.  The storage will hold approximately 88,000 Btu for  domestic hot water usage.  This allows the pellet boiler to fire for a period of approximately 30  minutes within its efficient firing range to charge the storage.  The heat in the storage is then  used to provide domestic hot water needs, until the temperature drops to ~140oF and the  system has to fire to charge it once more.    The wood pellet boilers, metering bin, expansion tank, valves, fittings, and boiler pump will be  installed in the existing boiler room.  A fuel storage bin capable of holding 30 tons of wood  pellets will be located next to the building to accept bulk deliveries of wood pellets  pneumatically or with an auger.  Wood pellets will be automatically transferred using a flexible  auger or pneumatic hose from the storage bin to a metering bin that feeds the wood pellet  boiler.  The wood pellet boiler will heat the hot water thermal storage system located in the  existing boiler room.   The hot water thermal storage will tie in with the existing heating  distribution pipes.  The existing fuel oil fired heating boilers would remain to supplement the  biomass system during periods of maintenance and if the heating demand is outside the range  of the biomass system.  Appendix A contains a conceptual site plan, floor plan, and schematic  for the biomass system. Figure 7 shows the estimated wood pellet system coverage of the FY  2013 load duration curve.  Biomass Prefeasibility Report Date: September 2, 2014 Tlingit‐Haida Regional Housing Authority   FINAL Prince of Wales Island, Alaska    WES Energy & Environment  Page 10 of 24    Figure 7 – Estimated Wood Pellet System Coverage of Load Duration Curve   Note: The load duration curve model is based on local weather data and annual fuel delivery volumes provided by  Tlingit‐Haida Regional Housing Authority.  Potential coverage of 99% is shown.  Actual coverage will depend on  management of loads and the use of thermal storage.  The system can be used as described in the text to cover  approximately 100% of the annual demand.  Management of loads, the use of thermal storage, and operations will  determine actual biomass coverage.      Figure 7 shows 99% biomass coverage of the FY 2013 load duration curve.  Actual coverage will  vary depending on weather conditions, peak demands, equipment operation schedules, and  periods when the boilers are shut down for maintenance.  This report assumes 95% coverage of  fuel oil usage for estimating the potential fuel use and savings for this memorandum.    4.1.2 Option 1b : 100,000 Btu/hr Cord Wood System An advanced combustion unit and hot water boiler capable of firing on seasoned cord wood  sized at approximately 100,000 Btu/hr of heat output is evaluated.  The boiler would be  combined with approximately 500 gallons of thermal storage to efficiently meet the center’s  range of heating needs.    Welcome Inn B&B in Thorne Bay provides half cords stacked and wrapped on a pallet.   Deliveries could be coordinated with up to 10 cords delivered at once.  A local freight company  provides the option to tow a forklift behind the truck for unloading. It is assumed that this  0.00 0.05 0.10 0.15 0.20 0.25 11325374961738597109121133145157169181193205217229241253265277289301313325337349361Heat Demand of Boiler Output (mmBtu/hr)Days Biomass Coverage Daily Average Heating Demand Daily Peak Heating Demand Biomass Prefeasibility Report Date: September 2, 2014 Tlingit‐Haida Regional Housing Authority   FINAL Prince of Wales Island, Alaska    WES Energy & Environment  Page 11 of 24  option is exercised and a forklift is not included in the budget.  A 600 ft2 cord wood storage  building will be constructed across the parking lot of the Klawock Senior Center.  This will allow  the storage of approximately 15 to 18 cords of wood.  The floor will be concrete to allow the  use of a pallet jack to roll a half cord at a time from the storage building, across the parking lot,  and into a more convenient location in the building to load the boiler.   Cord wood systems are manually loaded and operate efficiently while burning hot and fast.  Seasoned wood is loaded into the firebox, is lit, and should be operated at high fire.  Cord wood  boilers can “turn‐down” the heating output by reducing air to the firebox.  This causes the  wood to smolder and smoke is emitted due to inefficient combustion.   If a cord wood system is  rated at an average output of 100,000 Btu/hour over 8 hours, most of the heat is generated  during the first couple hours and then tapers off over the remaining period.  Because of this,  hot water thermal storage is crucial for efficient operation.  The hot water thermal storage will  provide a buffer for the boiler to charge the tank with more heat than is required for the  building.  The heat stored in the tank will then be used over the course of the day to heat the  building.  Additionally, the operator should try to gauge how much wood fuel to charge the fire  box with based on expected heat load.The firebox will likely not need to be filled to the top if it  is operating during the summer for only domestic hot water loads.   The hot water thermal storage will hold approximately 240,000 Btu for domestic hot water  usage.  Two 120 gallon superstore tanks are currently used for domestic hot water storage that  can store up to 125,000 Btu of heat total.  If the operator lit the boiler in the morning to charge  thermal storage system and the existing hot water super store tanks, the boiler would need to  be loaded approximately half full.  The tanks could then be charged again at the end of the day  if needed.  If the demand for hot water during the day exceeds what is stored in all of the tanks,  the fuel oil system would fire to bridge the gap.  The estimated coverage using the cord wood  boiler for the Klawock Senior Center is shown in Figure 8.      Biomass Prefeasibility Report Date: September 2, 2014 Tlingit‐Haida Regional Housing Authority   FINAL Prince of Wales Island, Alaska    WES Energy & Environment  Page 12 of 24    Figure 8 – Estimated Cord Wood System Coverage of Load Duration Curve   Note: The load duration curve model is based on local weather data and annual fuel delivery volumes provided by  Tlingit‐Haida Regional Housing Authority.  Potential coverage of 80% is shown.  Actual coverage will depend on  management of loads and the use of thermal storage.    Figure 8 shows 80% biomass coverage of the FY 2013 load duration curve as the red shaded  portion.  The existing fuel oil system will supplement the wood chip boiler during peak loads,  low loads, and during periods of maintenance.   Actual coverage will vary depending on  weather conditions, peak demands, equipment operation schedules, and periods when the  boilers are shut down for maintenance.  This report assumes 80% coverage of fuel oil usage for  estimating the potential fuel use and savings for this memorandum.  There are currently limited manufacturers who offer an ASME rated cord wood boiler.  An open  non pressurized system could be utilized with a non‐ASME rated boiler to heat the system with  piping and control modifications.  The non‐ASME rated boiler transfers heat to the existing  pressurized system via a heat exchanger.  Cost effective heat exchanger design will reduce the  temperature that can be delivered on the pressure side of the system by about 5 °F.  4.2 CRAIG SENIOR CENTER BIOMASS SYSTEM OPTIONS Two high efficiency low emission biomass fired boiler systems are evaluated for  interconnection with the existing heating system serving the Craig Senior Center.  Option 2a  0.00 0.05 0.10 0.15 0.20 0.25 11325374961738597109121133145157169181193205217229241253265277289301313325337349361Heat Demand of Boiler Output (mmBtu/hr)Days Biomass Coverage Daily Average Heating Demand Daily Peak Heating Demand Biomass Prefeasibility Report Date: September 2, 2014 Tlingit‐Haida Regional Housing Authority   FINAL Prince of Wales Island, Alaska    WES Energy & Environment  Page 13 of 24  considers a boiler system that would fire on wood pellets.  Option 2b considers a boiler system  that would fire on cord wood.    4.2.1 Option 2a : 110,000 Btu/hr Wood Pellet System One advanced combustion wood pellet boiler sized at approximately 0.11 mmBtu/hr of heat  output would be combined with approximately 200 gallons of thermal storage to efficiently  meet the range of heating needs.  The rated operating range of the system would be from  ~0.03 to ~0.11 mmBtu/hr with thermal storage allowing short term peaks to be met.  The hot  water thermal storage would be heated to a preset temperature (typically 195°F or higher) that  is higher than distributed for building heat.  The thermal storage tank would use a 3‐way mixing  valve to blend hot water in the tank with colder return water from the senior center to  maintain a range of supply water temperatures (160°F – 190°F) determined by an outside air  temperature reset schedule.  The storage would allow the system to meet a 1‐hr peak of ~0.13 mmBtu/hr and a 15 minute  peak of ~0.20 mmBtu/hr.  The storage would also allow one boiler to operate efficiently to  provide domestic hot water heating.  The storage will hold approximately 88,000 Btu for  domestic hot water usage.  This allows one pellet boiler to fire for a period of approximately 50  minutes within its efficient firing range to charge the storage.  The heat in the storage is then  used to provide domestic hot water needs, until the temperature drops to ~140oF and the  system has to fire to charge it once more.    The wood pellet boiler, thermal storage tank, metering bin, expansion tank, valves, fittings, and  distribution pumps will be factory installed in a roll off shipping container.  The container can  vary depending on the manufacturer selected, but can be a roll off shipping container or wood  paneled storage box.  A fuel storage bin capable of holding 30 tons of wood pellets will be  installed for fuel storage.  Smaller storage bins could be used, but typical bulk deliveries are  made in ~20 ton loads. This can be located adjacent to the building if a portion of the deck is  removed or in the front parking lot.   Wood pellets will be automatically transferred using a  flexible auger or pneumatic hose from the storage bin to a metering bin that feeds the wood  pellet boiler.  Heating distribution pipes will be installed from the wood pellet heating plant to  the existing fuel oil fired boiler plant.  The thermal storage system will be located in the existing  fuel oil boiler plant and tie‐in with the existing hot water heating system. The existing fuel oil  fired heating boilers would remain to supplement the biomass system during periods of  maintenance and if the heating demand is outside the range of the biomass system.  Appendix  A contains a conceptual site plan, floor plan, and schematic for the biomass system. Figure 9  shows the estimated wood pellet system coverage of the FY 2013 load duration curve.    Biomass Prefeasibility Report Date: September 2, 2014 Tlingit‐Haida Regional Housing Authority   FINAL Prince of Wales Island, Alaska    WES Energy & Environment  Page 14 of 24    Figure 9 – Estimated Wood Pellet System Coverage of Load Duration Curve   Note: The load duration curve model is based on local weather data and annual fuel delivery volumes provided by  Tlingit‐Haida Regional Housing Authority.  Potential coverage of 100% is shown.  Actual coverage will depend on  management of loads and the use of thermal storage.        Figure 9 shows 100% biomass coverage of the FY 2013 load duration curve.  Actual coverage  will vary depending on weather conditions, peak demands, equipment operation schedules,  and periods when the boilers are shut down for maintenance.  This report assumes 95%  coverage of fuel oil usage for estimating the potential fuel use and savings for this  memorandum.  4.2.2 Option 2b : 100,000 Btu/hr Cord Wood System An advanced combustion unit and hot water boiler capable of firing on seasoned cord wood  sized at approximately 100,000 Btu/hr of heat output is evaluated.  The boiler would be  combined with approximately 500 gallons of thermal storage to efficiently meet the center’s  range of heating needs.  This boiler size was chosen because typically it is the smallest boiler  offered by manufacturers.   The boiler operator would have to take care to charge the firebox  based on expected load to ensure that the boiler does not idle and produce excess smoke.    0.00 0.02 0.04 0.06 0.08 0.10 0.12 0.14 0.16 11325374961738597109121133145157169181193205217229241253265277289301313325337349361Heat Demand of Boiler Output (mmBtu/hr)Days Biomass Coverage Daily Average Heating Demand Daily Peak Heating Demand Biomass Prefeasibility Report Date: September 2, 2014 Tlingit‐Haida Regional Housing Authority   FINAL Prince of Wales Island, Alaska    WES Energy & Environment  Page 15 of 24  The hot water thermal storage will hold approximately 240,000 Btu for domestic hot water  usage.  One 100 gallon tank is currently used for domestic hot water storage that can store up  to 52,000 Btu of heat total.  If the operator lit the boiler in the morning to charge the thermal  storage system and the existing hot water super store tanks, the boiler would need to be  loaded approximately half full.  The tanks could then be charged again at the end of the day if  needed.  If the demand for hot water during the day exceeds what is stored in all of the tanks,  the fuel oil system would fire to bridge the gap.  The estimated coverage using the cord wood  boiler for the Craig Senior Center is shown in Figure 10.      Figure 10 – Estimated Cord Wood System Coverage of Load Duration Curve   Note: The load duration curve model is based on local weather data and annual fuel delivery volumes provided by  Tlingit‐Haida Regional Housing Authority.  Potential coverage of 86% is shown.  Actual coverage will depend on  management of loads and the use of thermal storage.  Figure 10 shows 86% coverage of the FY 2013 load duration curve using the cord wood system.   The existing fuel oil system in the boiler room will supplement the cord wood system as  needed.  Actual coverage will vary depending on weather conditions, peak demands,  equipment operation schedules, and periods when the boilers are shut down for maintenance.   This report assumes 80% coverage for the cord wood system for estimating the potential fuel  use and savings for the Craig Senior Center.  0.00 0.02 0.04 0.06 0.08 0.10 0.12 0.14 0.16 11325374961738597109121133145157169181193205217229241253265277289301313325337349361Heat Demand of Boiler Output (mmBtu/hr)Days Biomass Coverage Daily Average Heating Demand Daily Peak Heating Demand Biomass Prefeasibility Report Date: September 2, 2014 Tlingit‐Haida Regional Housing Authority   FINAL Prince of Wales Island, Alaska    WES Energy & Environment  Page 16 of 24  5.0 BENEFIT/COST ANALYSIS Capital costs are estimated for each option based on recent quotations and bids provided by  boiler manufacturers and recent bids for similar projects.  These costs include the fuel storage  and handling system, biomass combustion unit, boiler, accessory equipment, installation,  integration with the existing heating and domestic hot water systems, professional fees, and  contingency. The estimated capital costs for each Option are listed in Table 3.  Tables showing  the detailed cost breakdowns are found in Appendix B.    Table 3 – Estimated Project Capital Costs  Option Estimated  Capital Cost  1a – Klawock Senior Center Wood Pellet System $102,275  1b – Klawock Senior Center Cord Wood System $97,405  2a – Craig Senior Center Wood Pellet System $131,497  2b – Craig Senior Center Cord Wood System $103,667    It is assumed that existing staff would coordinate deliveries, empty ash bins, and check on the  system.  Ash removal costs have been estimated at $70 per ton of ash and $220 per container  delivery.  Option 1b would generate the largest quantity of ash and would result in  approximately 3 cubic yards annually.  Wood ash can be used as a direct replacement for lime  and costs for removal could be reduced if it is used as a soil amendment on school grounds or  other locations.    An increase in electricity use would occur from the circulation pumps and fuel handling system.   Electricity costs using a price of $0.1272/ kWh have been estimated considering motors for  pumps, augers, and fans for the wood pellet system and motors for pumps and fans for the  cord wood system.  Annual operation and maintenance (O&M) costs are estimated for each  option and are listed in Table 4.    Table 4 – Estimated Annual O&M Costs  Task Option 1a Option 1b Option 2a Option 2b  Electricity $350 $180 $360 $180  Ash Removal $240 $340 $230 $300  Annual Service $1,000 $1,000 $1,000 $1,000  Totals $1,590 $1,520 $1,590 $1,480  Note:  1 – Electricity costs are estimated at $0.1272/kWh as provided by Tlingit‐Haida Regional housing Authority.  2 – Ash removal costs are estimated at $70/ton and $220 per container delivery.  Ash generation is estimated at  0.5% by weight for wood pellets and 4% by weight for cord wood.  Ash is a valuable product that can be used a soil  amendment and costs for removal could be mitigated if used as such.     Biomass Prefeasibility Report Date: September 2, 2014 Tlingit‐Haida Regional Housing Authority   FINAL Prince of Wales Island, Alaska    WES Energy & Environment  Page 17 of 24  Annual operating savings are estimated considering fuel costs and O&M costs.  Table 5 shows  the estimated annual operating savings for each option.    Table 5 – Estimated Annual Operating Savings  Option  Current  Annual  Fuel Oil  Cost  Estimated  Annual  Biomass  Cost  Estimated  Annual Fuel Oil  Cost with  Biomass System  Estimated  Additional  Annual O&M  Costs  Estimated  Annual  Savings  1a – Klawock Senior Center Wood  Pellet System $20,650 $13,860 $1,033 $1,590 $4,168  1b – Klawock Senior Center Cord  Wood System $20,650 $8,500 $4,130 $1,520 $6,500  2a – Craig Senior Center Wood  Pellet System $12,390 $8,580 $620 $1,590 $1,601  2b – Craig Senior Center Cord  Wood System $12,390 $5,250 $2,478 $1,480 $3,182    A benefits summary is listed in Table 6 showing the estimated capital cost, 1st year net  operating savings, simple payback, 20 year Net Present Value, and 20 Year Benefits to Cost  (B/C) ratio.  Table 6 – Cost and Benefit Summary  Option Estimated  Capital Cost  1st Year  Net  Annual  Operating  Savings  Simple  Payback,  Years  20 Year Net  Present Value  20 Year B/C  Ratio  1a – Klawock Senior Center Wood  Pellet System $102,275 $4,168 24.5 (10,626) 0.90   1b – Klawock Senior Center Cord  Wood System $97,405 $6,500 15.0 37,842  1.39   2a – Craig Senior Center Wood  Pellet System $131,497 $1,601 82.2 (93,983) 0.29   2b – Craig Senior Center Cord  Wood System $103,667 $3,182 32.6 (36,461) 0.65    Notes:  1 – Net Annual Operating Savings include costs for wood fuel, supplemental fossil fuel, and operation &  maintenance (O&M) costs.  2 – 20 Year Net Present Value takes the present value of the operating savings for each year using a discount rate  of 3.0% as published in the “Energy Price Indices and Discount Factors for Life‐Cycle Cost Analysis ‐2013” and the  initial capital outlay of the total project cost.   A value greater than zero means that savings are greater than  expenses over 20 years in the value of today’s dollars.  3 – 20 Year Benefit/Cost (B/C) Ratio is calculated by dividing the present value of net annual operating savings over  a 20 year period with a discount rate of 3.0% by the Estimated Capital Cost. A value greater than 1 means the  benefits exceed the costs over a 20 year period.    Biomass Prefeasibility Report Date: September 2, 2014 Tlingit‐Haida Regional Housing Authority   FINAL Prince of Wales Island, Alaska    WES Energy & Environment  Page 18 of 24  A cash flow analysis was completed for financing the projects assuming a 20 year financing term  at a 4.0% interest rate.  None of the Options had a positive first year cash flow after annual  payments.  However, Option 1b was very close to breaking even and grant funding or better  financing rates could easily make this a positive cash flow project.  The detailed analyses are  shown in Appendix C.    A sensitivity analysis was completed comparing 20 year net present value for each option over  a range of annual oil inflation rates and 3.0% for remaining O&M costs.  Table 7 shows the  results of the 20 year net present value sensitivity analysis.     Table 7 – 20 Year Net Present Value Sensitivity to Oil Inflation Rate  Option  20 Year NPV  with Oil  Inflation at  3.0% Annually  20 Year NPV  with Oil  Inflation at  3.3% Annually  20 Year NPV  with Oil  Inflation at  4.0% Annually  20 Year NPV  with Oil  Inflation at  6.8% Annually  1a – Klawock Senior Center Wood  Pellet System ($21,353) ($10,626) $15,914  $146,943   1b – Klawock Senior Center Cord  Wood System $28,614  $37,647  $59,997  $170,338   2a – Craig Senior Center Wood  Pellet System ($100,419) ($93,983) ($78,059) $559   2b – Craig Senior Center Cord  Wood System ($41,880) ($36,461) ($23,051) $43,154   Note:  Net Present Values are calculated using annual inflation rates of 3% for wood fuel and O&M costs, the  inflation rate for oil stated in the table, the initial capital cost, and a discount rate of 3%    Table 8 lists the assumptions and values used to develop costs and savings in this study.                          Biomass Prefeasibility Report Date: September 2, 2014 Tlingit‐Haida Regional Housing Authority   FINAL Prince of Wales Island, Alaska    WES Energy & Environment  Page 19 of 24  Table 8 – Assumptions and Values Used in the Report  Item Value and Unit Source  Klawock Senior Center annual #1 fuel oil use 5,000 gallons Tlingit‐Haida Regional Housing Authority Craig Senior Center annual #1 fuel oil use 3,000 gallons Tlingit‐Haida Regional Housing Authority Option 1a portion of fuel oil replaced  95%WES E&E estimate  Option 1b portion of fuel oil replaced  80%WES E&E estimate  Option 2a portion of fuel oil replaced  95%WES E&E estimate  Option 2b portion of fuel oil replaced  80%WES E&E estimate  #1 Fuel oil heat content 134,000 Btu/gal WES E&E assumption  Cord wood moisture content wet basis 20%WES E&E assumption  Wood pellet moisture content wet basis 8%WES E&E assumption  Cord wood high heating value (Sitka Spruce) 18.1 mmBtu/Cord University of Alaska Fairbanks  Cooperative Extension Service  Wood pellet high heating value 15.2 mmBtu/ton WES E&E assumption  #1 Fuel oil boiler efficiency (HHV) 80%WES E&E assumption  Cord wood boiler efficiency (HHV) 70%WES E&E assumption  Wood pellet boiler efficiency (HHV) 80%WES E&E assumption  #1 Fuel oil price $4.13/gallon Tlingit‐Haida Regional Housing Authority Electricity price $0.1274 Tlingit‐Haida Regional Housing Authority Cord wood price $250.00/Cord Budget quote Wood pellet price $330.00/ton Budget quote Discount rate 3.0%NISTIR 85‐3273‐28  #1 Fuel oil inflation rate  3.3%WES E&E assumption  Wood pellet inflation rate 3.0%WES E&E assumption  O&M inflation rate 3.0%WES E&E assumption  Cord wood inflation rate 3.0%WES E&E assumption  6.0 CONCLUSIONS & RECOMMENDATIONS This study concludes that the Tlingit‐Haida Regional Housing Authority can reduce annual  operating costs for space heating and domestic hot water heating by installing a high efficiency,  low emission wood fired heating system for the Craig and Klawock Senior Centers.  The projects  will offset approximately 80% to 95% of the fuel oil use depending on the option selected.   The Klawock Senior Center has the potential for a cost effective project by using a high  efficiency gasification cord wood boiler system and hot water thermal storage.  Depending on  the rates and structure of the financing, the project has the potential for a positive first year  cash flow.  The Craig Senior Center has site space constraints that increase the capital costs of  the system.  Additionally, there is less fuel oil to be offset, making the economics not as  attractive.  Outside grant funding and low interest loans would improve economics and  potentially make a project possible.  If 80% of the project costs were secured through grant  funding, simple paybacks would range from 5 years for wood pellets to 3 years for cord wood  for the Klawock Senior Center and 16.5 years for wood pellets to 6.5 years for cord wood for  the Craig Senior Center.  Additional benefits that would be provided by a high efficiency, low  emission wood fired system include:   Purchase of cord wood will immediately impact the local economy since the fuel is  currently available in Thorne Bay;  Biomass Prefeasibility Report Date: September 2, 2014 Tlingit‐Haida Regional Housing Authority   FINAL Prince of Wales Island, Alaska    WES Energy & Environment  Page 20 of 24   Purchase of wood pellets will impact the regional economy, with pellet production  currently operational in Ketchikan, AK;    Decreased dependence on imported oil by replacing 2,400 to 2,850 gallons of #1 fuel oil  at the Craig Senior Center and 4,000 to 4,750 gallons of #1 fuel oil at the Klawock Senior  Center with renewable biomass fuel;   A hedge against volatility of the fossil fuel market;  As the Tlingit‐Haida Regional Housing Authority continues to pursue biomass energy options,  WES Energy & Environment recommends that the next level of evaluation includes detailed  consideration of the following items:   Selection of the wood fuel technology most appropriate for each site.   Siting of the fuel storage at the Klawock Senior Center.   Siting of the biomass plant and fuel storage at the Craig Senior Center.   Biomass system capital costs based on detailed site investigations, initial plant layout  and design, and direct quotes from manufacturers.     Alternative funding sources (low interest loans, grants, and incentives).     Biomass Prefeasibility Report Date: September 2, 2014 Tlingit‐Haida Regional Housing Authority   FINAL Prince of Wales Island, Alaska    WES Energy & Environment  Page 21 of 24  Source: http://www.woodboilers.com/products/pellet‐ boilers/froling‐p4‐pellet.html 7.0 GENERAL BIOMASS TECHNOLOGY INFORMATION This section describes technologies that can be used for efficiently using wood for space  heating and domestic hot water heating.  Manufacturers of each technology are available both  domestically and abroad. A partial list of manufacturers is provided for technologies and does  not constitute an endorsement.  Other manufacturers are available and individual  investigations should be completed prior to purchase. Local codes and regulations may require  modifications or additional components for compliance depending on the system considered.    High Efficiency Indoor Wood Pellet Boiler  High efficiency indoor wood pellet boilers utilize  premium wood pellets as a renewable biomass fuel  source for hot water space heating systems. Wood  pellets are automatically fed from an adjacent storage  hopper into the firebox based on heating demand.   Efficiencies can exceed 80% when coupled with a hot  water thermal storage system that allows the boiler to  operate at high fire to charge the hot water thermal  storage tank. Multiple boilers can be operated to  increase heating capacity.  Equipment costs can vary  depending on the heating capacity required.  Annual  savings can range from $3,000 to $6,000 per year based  on a facility using 5,000 gallons of #1 fuel oil per year at  current prices. Manual and automatic hopper loading is  available. Ash removal is manual. A partial list of  manufacturers include ACT Bioenergy, Froling, MESys,  Evo World, Windhager, Kedel, and Wood Master.         High Efficiency Indoor Cord Wood Boiler  High efficiency indoor cordwood boilers utilize split  cordwood as a renewable biomass fuel source for hot  water space heating systems. Efficiencies can exceed  70% when coupled with a hot water thermal storage  system that allows the cordwood boiler to operate at  high fire to charge the hot water thermal storage tank.  Equipment costs can range from $7,000 to $15,000 plus  installation.  Annual savings can range from $1,800 to  $2,200 per year based on an average building using  1,500 gallons of #1 fuel oil per year at current prices.  Manual loading and ash removal are required. A partial  list of manufacturers include Wood Gun, Econoburn,  Froling, Windhager, and Wood Master.  Source:  http://www.woodboilers.com/product s/woodboilers/froeling‐fhg.html Biomass Prefeasibility Report Date: September 2, 2014 Tlingit‐Haida Regional Housing Authority   FINAL Prince of Wales Island, Alaska    WES Energy & Environment  Page 22 of 24  Source: http://www.afsenergy.com/Biomass%20Energy.htm   Advanced Biomass Combustion Units and Boilers  Advanced biomass combustion units and boilers are  typically an engineered product capable of firing on  wood chips, saw mill residue, wood pellets, and saw  dust. Fuel is typically delivered in bulk semi‐trailer  loads and automatically conveyed to the  combustion unit. Efficiencies can exceed 70% when  coupled with a hot water thermal storage system.   Emission controls are typically required to clean up  exhaust gasses.  Capital costs are high and vary  depending on many factors. Annual fuel cost savings  can range from $100,000 to $120,000 per year  based on a facility using 50,000 gallons of #1 fuel oil  per year at current prices.  High fuel costs and high  fuel usage can potentially make a project feasible. A  partial list of manufacturers include Viessman, ACT  Bioenergy, Froling, MESys, Evo World, Wood  Master, Messersmith Manufacturing, AFS Energy  Systems, Solagen, Wellons FEI, and Hurst.  Hot Water Thermal Storage System  Thermal storage tanks, also known as accumulator  tanks or buffer tanks, can raise the efficiency of hot  water heating systems firing on wood.  Solid fuels  burn more efficiently at higher firing rates than at  lower rates or idle modes where the fuel smolders,  smokes, and wastes energy.  Hot water thermal  storage allows the solid fuel boiler to fire efficiently  at full output to store the heat at elevated  temperatures in storage tanks. For optimum  operation a mixing valve is installed to blend cold  water returning from the facility with hot water  stored in the thermal storage tank.  Hot water is sent  back to the facility at a temperature that is lower  than the storage tanks, providing heat storage and a  buffer for short periods of high demand.  This  method of operation reduces smoldering and  smoking from inefficient operation, fuel use,  creosote buildup, and the need for frequent stoking.  Source: http://www.viessmann‐ us.com/en/District_Heating/Products/dhw/Stor age_Tanks.html Biomass Prefeasibility Report Date: September 2, 2014 Tlingit‐Haida Regional Housing Authority   FINAL Prince of Wales Island, Alaska    WES Energy & Environment  Page 23 of 24  Source: WES Energy & Environment File Photo District Piping Systems  It can often be cost effective to connect multiple  buildings to one central wood fired heating plant.   Long runs of buried piping can be installed cost  effectively using pre‐insulated PEX piping.  It is  important to use factory injected close cell foam  insulation with a High Density Polyethylene (HDPE)  insulation jacket to prevent the insulation from being  compromised from ground water or leaks.   Pipe sizes  can range from 3/4” to 5” with roll lengths up to 600  feet.  Pipe material costs can be more expensive than  traditional iron pipe, however installation costs can  be reduced due to longer runs between splices and  connections.               Biomass Prefeasibility Report Date: September 2, 2014 Tlingit‐Haida Regional Housing Authority   FINAL Prince of Wales Island, Alaska    WES Energy & Environment                Appendix A  Conceptual Drawings                                  SCALE100'0'50'100'Klawock Senior CenterWESEE Klawock Senior Center Klawock, AK Site Plan SCALE10'0'5'10'ThermalStorageTankBiomass BoilerExistingBoilersPavingCord WoodStorage 35'x20'ExistingStructureExisitng BuildingWESEE Klawock Senior Center Klawock, AK Option 1a Plan View To ExistingHeating SystemWood PelletBoiler160,000 Btu/hr200 GallonThermalStorage TankFrom LoadTo LoadBoiler Protection ValveValve to be controlled to maintainDWOHDVWƒWRERLOHUVVFDTTTIVariable Frequency DriveTemperature TransmitterPumpThree Way Mixing ValveLegendFrom ExistingHeating SystemTTTIVFDTemperature IndicatorTTTI210,000 Btu/hrExisting FuelOil Boiler210,000 Btu/hrExisting FuelOil BoilerWESEE Klawock Senior Center Klawock, AK Option 1a SchematicNote: This drawing is a conceptual schematic for the purposesof showing a general biomass system arrangement. Equipment,final sizing, and pressures will vary depending on the engineer,manufacturer and contractor installing the biomass system. SCALE10'0'5'10'ThermalStorageTankBiomass BoilerExistingBoilersPavingExistingStructureExisitng BuildingWood Pellet StorageFuel AugerFill Hole(Typ.)WESEE Klawock Senior Center Klawock, AK Option 1b Plan View To ExistingHeating System200 GallonThermalStorage TankFrom LoadTo LoadBoiler Protection ValveValve to be controlled to maintainDWOHDVWƒWRERLOHUVVFDTTTIVariable Frequency DriveTemperature TransmitterPumpThree Way Mixing ValveLegendFrom ExistingHeating SystemTTTIVFDTemperature IndicatorTTTI210,000 Btu/hrExisting FuelOil Boiler210,000 Btu/hrExisting FuelOil BoilerCord WoodBoiler100,000 Btu/hrWESEE Klawock Senior Center Klawock, AK Option 1b SchematicNote: This drawing is a conceptual schematic for the purposesof showing a general biomass system arrangement. Equipment,final sizing, and pressures will vary depending on the engineer,manufacturer and contractor installing the biomass system. Craig Senior CenterSCALE100'0'50'100'WESEE Craig Senior Center Craig, AK Site Plan SCALE50'0'25'50'WESEE Craig Senior Center Craig, AK Option 2a Site Layout BoilerMeteringBinStackExpansionTankRemove Stairs,Access via RampRamp UpCraig Senior CenterSCALE5'0'2.5'5'Ramp Up ThermalStorage TankConcretePadFuel StorageFuel AugerWESEE Craig Senior Center Craig, AK Option 2a Site Plan To ExistingHeating SystemWood PelletBoilerThermalStorageTankFrom LoadTo LoadBoiler Protection ValveValve to be controlled to maintainDWOHDVWƒWRERLOHUVVFDTTTIVariable Frequency DriveTemperature TransmitterPumpThree Way Mixing ValveLegendFrom ExistingHeating SystemTTTIVFDTemperature IndicatorTTTIExisting FuelOil BoilerTo Sr. CenterBoiler RoomFrom Sr. CenterBoiler RoomExisting FuelOil BoilerWESEE Craig Senior Center Craig, AK Option 2a SchematicNote: This drawing is a conceptual schematic for the purposesof showing a general biomass system arrangement. Equipment,final sizing, and pressures will vary depending on the engineer,manufacturer and contractor installing the biomass system. SCALE50'0'25'50'WESEE Craig Senior Center Craig, AK Option 2b Site Layout BoilerStackCord Wood Storage10'x20'ExpansionTankRamp UpCraig Senior CenterSCALE5'0'2.5'5'Ramp Up ThermalStorage TankSidewalkWESEE Craig Senior Center Craig, AK Option 2b Site Plan To ExistingHeating SystemCord WoodBoilerThermalStorageTankFrom LoadTo LoadBoiler Protection ValveValve to be controlled to maintainDWOHDVWƒWRERLOHUVVFDTTTIVariable Frequency DriveTemperature TransmitterPumpThree Way Mixing ValveLegendFrom ExistingHeating SystemTTTIVFDTemperature IndicatorTTTIExisting FuelOil BoilerTo Sr. CenterBoiler RoomFrom Sr. CenterBoiler RoomExisting FuelOil BoilerWESEE Craig Senior Center Craig, AK Option 2b SchematicNote: This drawing is a conceptual schematic for the purposesof showing a general biomass system arrangement. Equipment,final sizing, and pressures will vary depending on the engineer,manufacturer and contractor installing the biomass system. Biomass Prefeasibility Report Date: September 2, 2014 Tlingit‐Haida Regional Housing Authority   FINAL Prince of Wales Island, Alaska    WES Energy & Environment                          Appendix B  Preliminary Capital Cost Estimates                                    Appendix B Tlingit‐Haida Regional Housing Authority Line Item Cost One (1) ‐ 160,000 Btu/hr wood pellet hot water boiler, installed 30,000$                    30 ton storage bin 15,000$                    Storage bin site work 5,000$                      Thermal storage 200 gal with insulation 7,000$                      Interconnection with existing boiler room, pumps, installation 7,500$                      Electrical 4,500$                      Mechanical 4,500$                      Sub‐Total 73,500$                    Contractor Profit 10% 7,350$                     Sub‐Total 80,850$                   Contingency 10% 8,085$                     Sub‐Total 88,935$                   Profesional Services 15% 13,340$                   Total 102,275$                 Notes: 3 ‐ Estimate is based on competitive bidding. Option 1a ‐ Conceptual Cost Estimate ‐ Klawock Senior Center  Wood Pellet Boiler System 1 ‐ The boiler system is to be installed in the existing boiler room.  Pricing is based on a one‐boiler solution.   There are multiple manufacturers that can provide varying boiler sizes.  Other boiler sizing combinations to  meet a similar output range may also be selected.  2 ‐ Professional Services includes permitting, legal, engineering, & project management. (Assumed that  minimal engineering is required.) WES Energy & Environment Appendix B Tlingit‐Haida Regional Housing Authority Line Item Cost One (1) ‐ 100,000 Btu/hr cord wood boiler, freight, and installed 13,000$                    Stick frame storage building with poured concrete floor, 600 ft2 @ $50/ft2 30,000$                    Thermal storage 500 gal with insulation 9,500$                      Interconnection with existing boiler room, pumps, installation 7,500$                      Electrical 5,000$                      Mechanical 5,000$                      Sub‐Total 70,000$                    Contractor Profit 10% 7,000$                     Sub‐Total 77,000$                   Contingency 10% 7,700$                     Sub‐Total 84,700$                   Profesional Services 15% 12,705$                   Total 97,405$                   Notes: 3 ‐ Estimate is based on competitive bidding. Option 1b ‐ Conceptual Cost Estimate ‐ Klawock Senior Center  Cord Wood Boiler System 1 ‐ The boiler system is to be installed in the existing boiler room.  Pricing is based on a one‐boiler solution.   There are multiple manufacturers that can provide varying boiler sizes.  Other boiler sizing combinations to  meet a similar output range may also be selected.  2 ‐ Professional Services includes permitting, legal, engineering, & project management. (Assumed that  minimal engineering is required.) WES Energy Environment Appendix B Tlingit‐Haida Regional Housing Authority Line Item Cost One (1) ‐ 100,000 Btu/hr wood pellet hot water boiler,  containerized 50,000$                    30 ton storage bin 15,000$                    Storage bin site work 5,000$                      Thermal storage 200 gal with insulation 7,000$                      Interconnection with existing boiler room, pumps, installation 7,500$                      Electrical 5,000$                      Mechanical 5,000$                      Sub‐Total 94,500$                    Contractor Profit 10% 9,450$                     Sub‐Total 103,950$                Contingency 10% 10,395$                   Sub‐Total 114,345$                Profesional Services 15% 17,152$                   Total 131,497$                 Notes: 3 ‐ Estimate is based on competitive bidding. Option 2a ‐ Conceptual Cost Estimate ‐ Craig Senior Center  Wood Pellet Boiler System 1 ‐ The boiler system is to be installed in the existing boiler room.  Pricing is based on a one‐boiler solution.   There are multiple manufacturers that can provide varying boiler sizes.  Other boiler sizing combinations to  meet a similar output range may also be selected.  2 ‐ Professional Services includes permitting, legal, engineering, & project management. (Assumed that  minimal engineering is required.) WES Energy & Environment Appendix B Tlingit‐Haida Regional Housing Authority Line Item Cost One (1) ‐ 100,000 Btu/hr cord wood boiler, freight, containerized, and installed 40,000$                    Stick frame storage building with poured concrete floor, 200 ft2 @ $50/ft2 10,000$                    Thermal storage 500 gal with insulation 9,500$                      Interconnection with existing boiler room, pumps, installation 5,000$                      Electrical 5,000$                      Mechanical 5,000$                      Sub‐Total 74,500$                    Contractor Profit 10% 7,450$                     Sub‐Total 81,950$                   Contingency 10% 8,195$                     Sub‐Total 90,145$                   Profesional Services 15% 13,522$                   Total 103,667$                 Notes: 3 ‐ Estimate is based on competitive bidding. Option 2b ‐ Conceptual Cost Estimate ‐ Craig Senior Center  Cord Wood Boiler System 1 ‐ The boiler system is to be installed in the existing boiler room.  Pricing is based on a one‐boiler solution.   There are multiple manufacturers that can provide varying boiler sizes.  Other boiler sizing combinations to  meet a similar output range may also be selected.  2 ‐ Professional Services includes permitting, legal, engineering, & project management. (Assumed that  minimal engineering is required.) WES Energy & Environment Biomass Prefeasibility Report Date: September 2, 2014 Tlingit‐Haida Regional Housing Authority   FINAL Prince of Wales Island, Alaska    WES Energy & Environment                      Appendix C  20 Year Financing at 4% APR Cash Flow Analysis                                        Appendix COption 1a ‐ Klawock Senior Center Wood Pellet Boiler System20 Year, 4% FinancingTlingit‐Haida Regional Housing AuthorityInput Variables Value Units Year #1 Fuel Oil Cost, Current System Wood Pellet Cost  #1 Fuel Oil Cost, w/ Wood System  Added O&M Cost  Net Operating Savings  Annual Financing Payment  Net Cash Flow  Present Value of Cash Flow Project Costs Financed 102,275 $ 1 20,650$         (13,860)$     (1,033)$          (1,590)$     4,168$        (7,526)$        (3,358)$       (3,358)$           Financing Term 20 # years 2 21,331$         (14,276)$     (1,067)$          (1,638)$     4,351$        (7,526)$        (3,174)$       (3,082)$           Financing Rate (apr) 4.0% Percent 3 22,035$         (14,704)$     (1,102)$          (1,687)$     4,543$        (7,526)$        (2,983)$       (2,812)$           Current #1 Fuel Oil Usage5,000 gal 4 22,763$         (15,145)$     (1,138)$          (1,737)$     4,742$        (7,526)$        (2,784)$       (2,548)$           Year 1 #1 Fuel Oil Average Price $4.13 $/gal 5 23,514$         (15,600)$     (1,176)$          (1,790)$     4,949$        (7,526)$        (2,577)$       (2,289)$           Proposed Annual Wood Pellet Usage 42 tons/yr 6 24,290$         (16,068)$     (1,214)$          (1,843)$     5,164$        (7,526)$        (2,361)$       (2,037)$           Year 1 Wood Pellet Purchase Price $330 $/ton 7 25,091$         (16,550)$     (1,255)$          (1,899)$     5,389$        (7,526)$        (2,137)$       (1,790)$           Annual #1 Fuel Oil Usage w/ Wood System 250 gal/yr 8 25,919$         (17,046)$     (1,296)$          (1,955)$     5,622$        (7,526)$        (1,904)$       (1,548)$           Fossil Fuel Inflation Rate (apr) 3.3% Percent 9 26,775$         (17,557)$     (1,339)$          (2,014)$     5,864$        (7,526)$        (1,661)$       (1,311)$           Wood Pellet Inflation Rate (apr) 3.0% Percent 10 27,658$         (18,084)$     (1,383)$          (2,075)$     6,116$        (7,526)$        (1,409)$       (1,080)$           O&M Inflation Rate 3.0% Percent 11 28,571$         (18,627)$     (1,429)$          (2,137)$     6,379$        (7,526)$        (1,147)$       (853)$               Discount Rate (apr) 3.0% Percent 12 29,514$         (19,185)$     (1,476)$          (2,201)$     6,652$        (7,526)$        (874)$          (631)$               Added Annual O&M Costs for Biomass Plant 1,590$         $/yr 13 30,488$         (19,761)$     (1,524)$          (2,267)$     6,935$        (7,526)$        (590)$          (414)$               14 31,494$         (20,354)$     (1,575)$          (2,335)$     7,230$        (7,526)$        (295)$          (201)$               15 32,533$         (20,964)$     (1,627)$          (2,405)$     7,537$        (7,526)$        11$              7$                    16 33,607$         (21,593)$     (1,680)$          (2,477)$     7,856$        (7,526)$        330$           212$                17 34,716$         (22,241)$     (1,736)$          (2,551)$     8,187$        (7,526)$        662$           412$                18 35,861$         (22,908)$     (1,793)$          (2,628)$     8,532$        (7,526)$        1,006$        609$                19 37,045$         (23,596)$     (1,852)$          (2,707)$     8,890$        (7,526)$        1,364$        801$                20 38,267$         (24,304)$     (1,913)$          (2,788)$     9,262$        (7,526)$        1,737$        990$                Present Value (20,922)$         WES Energy & Environment Appendix COption 1b ‐ Klawock Senior Center ‐ Cord Wood Boiler System20 Year, 4% FinancingTlingit‐Haida Regional Housing AuthorityInput Variables Value Units Year #1 Fuel Oil Cost, Current System  Cord Wood Cost  #1 Fuel Oil Cost, w/ Wood System  Added O&M Cost  Net Operating Savings  Annual Financing Payment  Net Cash Flow  Present Value of Cash Flow Project Costs Financed 97,405 $ 1 20,650$          (8,500)$        (4,130)$          (1,530)$     6,490$        (7,167)$        (677)$          (658)$               Financing Term 20 # years 2 21,331$          (8,755)$        (4,266)$          (1,576)$     6,734$        (7,167)$        (433)$          (408)$               Financing Rate (apr) 4.0% Percent 3 22,035$          (9,018)$        (4,407)$          (1,623)$     6,987$        (7,167)$        (180)$          (164)$               Current #1 Fuel Oil Usage5,000 gal 4 22,763$          (9,288)$        (4,553)$          (1,672)$     7,250$        (7,167)$        83$              74$                  Year 1 #1 Fuel Oil Average Price $4.13 $/gal 5 23,514$          (9,567)$        (4,703)$          (1,722)$     7,522$        (7,167)$        355$           306$                Proposed Annual Cord Wood Usage 34 Cords/yr 6 24,290$          (9,854)$        (4,858)$          (1,774)$     7,804$        (7,167)$        637$           533$                Year 1 Cord Wood Purchase Price $250 $/Cord 7 25,091$          (10,149)$     (5,018)$          (1,827)$     8,097$        (7,167)$        929$           756$                Annual #1 Fuel Oil Usage w/ Wood System 1,000 gal/yr 8 25,919$          (10,454)$     (5,184)$          (1,882)$     8,400$        (7,167)$        1,233$        973$                Fossil Fuel Inflation Rate (apr) 3.3% Percent 9 26,775$          (10,768)$     (5,355)$          (1,938)$     8,714$        (7,167)$        1,547$        1,185$             Cord Wood  Inflation Rate (apr) 3.0% Percent 10 27,658$          (11,091)$     (5,532)$          (1,996)$     9,040$        (7,167)$        1,872$        1,393$             O&M Inflation Rate 3.0% Percent 11 28,571$          (11,423)$     (5,714)$          (2,056)$     9,377$        (7,167)$        2,210$        1,597$             Discount Rate (apr) 3.0% Percent 12 29,514$          (11,766)$     (5,903)$          (2,118)$     9,727$        (7,167)$        2,560$        1,795$             Added Annual O&M Costs for Biomass Plant 1,530$         $/yr 13 30,488$          (12,119)$     (6,098)$          (2,181)$     10,090$     (7,167)$        2,923$        1,990$             14 31,494$          (12,483)$     (6,299)$          (2,247)$     10,466$     (7,167)$        3,298$        2,181$             15 32,533$          (12,857)$     (6,507)$          (2,314)$     10,855$     (7,167)$        3,688$        2,367$             16 33,607$          (13,243)$     (6,721)$          (2,384)$     11,259$     (7,167)$        4,092$        2,550$             17 34,716$          (13,640)$     (6,943)$          (2,455)$     11,677$     (7,167)$        4,510$        2,729$             18 35,861$          (14,049)$     (7,172)$          (2,529)$     12,111$     (7,167)$        4,944$        2,904$             19 37,045$          (14,471)$     (7,409)$          (2,605)$     12,560$     (7,167)$        5,393$        3,076$             20 38,267$          (14,905)$     (7,653)$          (2,683)$     13,026$     (7,167)$        5,859$        3,244$             Present Value 28,422$          WES Energy & Environment Appendix COption 2a ‐ Craig Senior Center Wood Pellet Boiler System20 Year, 4% FinancingTlingit‐Haida Regional Housing AuthorityInput Variables Value Units Year #1 Fuel Oil Cost, Current System Wood Pellet Cost  #1 Fuel Oil Cost, w/ Wood System  Added O&M Cost  Net Operating Savings  Annual Financing Payment  Net Cash Flow  Present Value of Cash Flow Project Costs Financed 131,497 $ 1 12,390$          (8,580)$        (620)$             (1,590)$     1,601$        (9,676)$        (8,075)$       (7,840)$           Financing Term 20 # years 2 12,799$          (8,837)$        (640)$             (1,638)$     1,684$        (9,676)$        (7,992)$       (7,533)$           Financing Rate (apr) 4.0% Percent 3 13,221$          (9,103)$        (661)$             (1,687)$     1,771$        (9,676)$        (7,905)$       (7,234)$           Current #1 Fuel Oil Usage3,000 gal 4 13,658$          (9,376)$        (683)$             (1,737)$     1,862$        (9,676)$        (7,814)$       (6,943)$           Year 1 #1 Fuel Oil Average Price $4.13 $/gal 5 14,108$          (9,657)$        (705)$             (1,790)$     1,956$        (9,676)$        (7,719)$       (6,659)$           Proposed Annual Wood Pellet Usage 26 tons/yr 6 14,574$          (9,947)$        (729)$             (1,843)$     2,055$        (9,676)$        (7,620)$       (6,382)$           Year 1 Wood Pellet Purchase Price $330 $/ton 7 15,055$          (10,245)$     (753)$             (1,899)$     2,158$        (9,676)$        (7,517)$       (6,112)$           Annual #1 Fuel Oil Usage w/ Wood System 150 gal/yr 8 15,552$          (10,552)$     (778)$             (1,955)$     2,266$        (9,676)$        (7,410)$       (5,849)$           Fossil Fuel Inflation Rate (apr) 3.3% Percent 9 16,065$          (10,869)$     (803)$             (2,014)$     2,378$        (9,676)$        (7,297)$       (5,593)$           Wood Pellet Inflation Rate (apr) 3.0% Percent 10 16,595$          (11,195)$     (830)$             (2,075)$     2,496$        (9,676)$        (7,180)$       (5,343)$           O&M Inflation Rate 3.0% Percent 11 17,143$          (11,531)$     (857)$             (2,137)$     2,618$        (9,676)$        (7,058)$       (5,099)$           Discount Rate (apr) 3.0% Percent 12 17,708$          (11,877)$     (885)$             (2,201)$     2,745$        (9,676)$        (6,931)$       (4,861)$           Added Annual O&M Costs for Biomass Plant 1,590$         $/yr 13 18,293$          (12,233)$     (915)$             (2,267)$     2,878$        (9,676)$        (6,798)$       (4,629)$           14 18,896$          (12,600)$     (945)$             (2,335)$     3,016$        (9,676)$        (6,659)$       (4,403)$           15 19,520$          (12,978)$     (976)$             (2,405)$     3,161$        (9,676)$        (6,515)$       (4,182)$           16 20,164$          (13,367)$     (1,008)$          (2,477)$     3,311$        (9,676)$        (6,365)$       (3,966)$           17 20,829$          (13,768)$     (1,041)$          (2,551)$     3,468$        (9,676)$        (6,208)$       (3,756)$           18 21,517$          (14,181)$     (1,076)$          (2,628)$     3,631$        (9,676)$        (6,044)$       (3,550)$           19 22,227$          (14,607)$     (1,111)$          (2,707)$     3,802$        (9,676)$        (5,874)$       (3,350)$           20 22,960$          (15,045)$     (1,148)$          (2,788)$     3,979$        (9,676)$        (5,697)$       (3,154)$           Present Value (106,437)$       WES Energy & Environment Appendix COption 2b ‐ Craig Senior Center ‐ Cord Wood Boiler System20 Year, 4% FinancingTlingit‐Haida Regional Housing AuthorityInput Variables Value Units Year #1 Fuel Oil Cost, Current System  Cord Wood Cost  #1 Fuel Oil Cost, w/ Wood System  Added O&M Cost  Net Operating Savings  Annual Financing Payment  Net Cash Flow  Present Value of Cash Flow Project Costs Financed 103,667 $ 1 12,390$          (5,250)$        (2,478)$          (1,480)$     3,182$        (7,628)$        (4,446)$       (4,316)$           Financing Term 20 # years 2 12,799$          (5,408)$        (2,560)$          (1,524)$     3,307$        (7,628)$        (4,321)$       (4,073)$           Financing Rate (apr) 4.0% Percent 3 13,221$          (5,570)$        (2,644)$          (1,570)$     3,437$        (7,628)$        (4,191)$       (3,835)$           Current #1 Fuel Oil Usage3,000 gal 4 13,658$          (5,737)$        (2,732)$          (1,617)$     3,572$        (7,628)$        (4,056)$       (3,604)$           Year 1 #1 Fuel Oil Average Price $4.13 $/gal 5 14,108$          (5,909)$        (2,822)$          (1,666)$     3,712$        (7,628)$        (3,916)$       (3,378)$           Proposed Annual Cord Wood  Usage 21 Cords/yr 6 14,574$          (6,086)$        (2,915)$          (1,716)$     3,857$        (7,628)$        (3,771)$       (3,158)$           Year 1 Cord Wood  Purchase Price $250 $/Cord 7 15,055$          (6,269)$        (3,011)$          (1,767)$     4,008$        (7,628)$        (3,620)$       (2,944)$           Annual #1 Fuel Oil Usage w/ Wood System 600 gal/yr 8 15,552$          (6,457)$        (3,110)$          (1,820)$     4,164$        (7,628)$        (3,464)$       (2,734)$           Fossil Fuel Inflation Rate (apr) 3.3% Percent 9 16,065$          (6,651)$        (3,213)$          (1,875)$     4,326$        (7,628)$        (3,302)$       (2,530)$           Cord Wood  Inflation Rate (apr) 3.0% Percent 10 16,595$          (6,850)$        (3,319)$          (1,931)$     4,495$        (7,628)$        (3,133)$       (2,331)$           O&M Inflation Rate 3.0% Percent 11 17,143$          (7,056)$        (3,429)$          (1,989)$     4,669$        (7,628)$        (2,959)$       (2,137)$           Discount Rate (apr) 3.0% Percent 12 17,708$          (7,267)$        (3,542)$          (2,049)$     4,851$        (7,628)$        (2,777)$       (1,948)$           Added Annual O&M Costs for Biomass Plant 1,480$         $/yr 13 18,293$          (7,485)$        (3,659)$          (2,110)$     5,039$        (7,628)$        (2,589)$       (1,763)$           14 18,896$          (7,710)$        (3,779)$          (2,173)$     5,234$        (7,628)$        (2,394)$       (1,583)$           15 19,520$          (7,941)$        (3,904)$          (2,239)$     5,436$        (7,628)$        (2,192)$       (1,407)$           16 20,164$          (8,179)$        (4,033)$          (2,306)$     5,646$        (7,628)$        (1,982)$       (1,235)$           17 20,829$          (8,425)$        (4,166)$          (2,375)$     5,864$        (7,628)$        (1,764)$       (1,067)$           18 21,517$          (8,677)$        (4,303)$          (2,446)$     6,090$        (7,628)$        (1,538)$       (904)$               19 22,227$          (8,938)$        (4,445)$          (2,520)$     6,324$        (7,628)$        (1,304)$       (744)$               20 22,960$          (9,206)$        (4,592)$          (2,595)$     6,567$        (7,628)$        (1,061)$       (587)$               Present Value (46,279)$         WES Energy & Environment Biomass Prefeasibility Report Date: September 2, 2014 Tlingit‐Haida Regional Housing Authority   FINAL Prince of Wales Island, Alaska    WES Energy & Environment                          Appendix D  Sensitivity Analysis of Estimated Annual Operating Savings   to Oil and Biomass Fuel Prices                                 Appendix DOption 1a ‐ Klawock Senior Center Wood Pellet Boiler SystemSensitivity Analysis of 1st Year Operating Savings to Fuel CostsTlingit‐Haida Regional Housing Authority4,168$  $3.50 $3.75 $4.00 $4.13 $4.25 $4.50 $4.75 $5.00$225$5,585 $6,773 $7,960 $8,578 $9,148 $10,335 $11,523 $12,710$250$4,535 $5,723 $6,910 $7,528 $8,098 $9,285 $10,473 $11,660$275$3,485 $4,673 $5,860 $6,478 $7,048 $8,235 $9,423 $10,610$300$2,435 $3,623 $4,810 $5,428 $5,998 $7,185 $8,373 $9,560$330$1,175 $2,363 $3,550 $4,168 $4,738 $5,925 $7,113 $8,300$350$335 $1,523 $2,710 $3,328 $3,898 $5,085 $6,273 $7,460$375($715) $473 $1,660 $2,278 $2,848 $4,035 $5,223 $6,410*Note: Excludes financing costs.Price of Wood Pellets per TonPrice of Fuel Oil per GallonWES Energy & Environment Appendix DOption 1b ‐ Klawock Senior Center ‐ Cord Wood Boiler SystemSensitivity Analysis of 1st Year Operating Savings to Fuel CostsTlingit‐Haida Regional Housing Authority6,490$  $3.50 $3.75 $4.00 $4.13 $4.25 $4.50 $4.75 $5.00$150$7,370 $8,370 $9,370 $9,890 $10,370 $11,370 $12,370 $13,370$175$6,520 $7,520 $8,520 $9,040 $9,520 $10,520 $11,520 $12,520$200$5,670 $6,670 $7,670 $8,190 $8,670 $9,670 $10,670 $11,670$225$4,820 $5,820 $6,820 $7,340 $7,820 $8,820 $9,820 $10,820$250$3,970 $4,970 $5,970 $6,490 $6,970 $7,970 $8,970 $9,970$275$3,120 $4,120 $5,120 $5,640 $6,120 $7,120 $8,120 $9,120$300$2,270 $3,270 $4,270 $4,790 $5,270 $6,270 $7,270 $8,270*Note: Excludes financing costs.Price of Cord Wood per CordPrice of Fuel Oil per GallonWES Energy & Environment Appendix DOption 2a ‐ Craig Senior Center Wood Pellet Boiler SystemSensitivity Analysis of 1st Year Operating Savings to Fuel CostsTlingit‐Haida Regional Housing Authority1,601$  $3.50 $3.75 $4.00 $4.13 $4.25 $4.50 $4.75 $5.00$225$2,535 $3,248 $3,960 $4,331 $4,673 $5,385 $6,098 $6,810$250$1,885 $2,598 $3,310 $3,681 $4,023 $4,735 $5,448 $6,160$275$1,235 $1,948 $2,660 $3,031 $3,373 $4,085 $4,798 $5,510$300$585 $1,298 $2,010 $2,381 $2,723 $3,435 $4,148 $4,860$330($195) $518 $1,230 $1,601 $1,943 $2,655 $3,368 $4,080$350($715) ($3) $710 $1,081 $1,423 $2,135 $2,848 $3,560$375($1,365) ($653) $60 $431 $773 $1,485 $2,198 $2,910*Note: Excludes financing costs.Price of Wood Pellets per TonPrice of Fuel Oil per GallonWES Energy & Environment Appendix DOption 2b ‐ Craig Senior Center ‐ Cord Wood Boiler SystemSensitivity Analysis of 1st Year Operating Savings to Fuel CostsTlingit‐Haida Regional Housing Authority3,182$  $3.50 $3.75 $4.00 $4.13 $4.25 $4.50 $4.75 $5.00$150$3,770 $4,370 $4,970 $5,282 $5,570 $6,170 $6,770 $7,370$175$3,245 $3,845 $4,445 $4,757 $5,045 $5,645 $6,245 $6,845$200$2,720 $3,320 $3,920 $4,232 $4,520 $5,120 $5,720 $6,320$225$2,195 $2,795 $3,395 $3,707 $3,995 $4,595 $5,195 $5,795$250$1,670 $2,270 $2,870 $3,182 $3,470 $4,070 $4,670 $5,270$275$1,145 $1,745 $2,345 $2,657 $2,945 $3,545 $4,145 $4,745$300$620 $1,220 $1,820 $2,132 $2,420 $3,020 $3,620 $4,220*Note: Excludes financing costs.Price of Cord Wood per CordPrice of Fuel Oil per GallonWES Energy & Environment