Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
City and Borough of Wrangell - Wrangell Electric Vehicle Feasibility Study - Report Volume 2 - April 2013 - REF Grant 7040070
ELECTRIC VEHICLES & PLUGIN HYBRID ELECTRIC VEHICLES A FEASIBILITY STUDY FOR THE CITY & BOROUGH OF WRANGELL, ALASKA April 26, 2013 Report – Volume 2 Alaska Energy Authority Grant Agreement Number 7040070 Volume 2 Appendix A. Wrangell Fleet Analysis Appendix B. Manufacturer Information Appendix C. EV Related Resources Appendix D. Safety and Permitting Appendix E. Fleet Charging Appendix F. Demand Control & Smart Grid Information Appendix G. Samples – DOE Vehicle Cost Calculator Appendix A. Wrangell Fleet Analysis City and Borough of Wrangell Alaska Existing Vehicle Fleet Analysis - Sort by USE by WHPacific, Inc. 4/19/2013 Page 1 of 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 A B C D E F H L O P Q Model Year Make Model Body Type Use # of Seats Insured Value Is Vehicle Garaged? Likely EV Candidate?Reasons Likely PHEV Candidate? 1986 Buick Hearse Van, Cargo 5 13,000 Y 1995 Ford Explorer Van, Pass City Admin 5 6,250 N 1984 GMC Line Truck Truck ELECTRICAL DEPT.3 5,000 Y 2003 Ford Ambulance Ambulance FIRE 2 115,000 Y N Unfeasible 2008 Ford F450 4x4 Ambulance Ambulance FIRE 110,000 Y N Unfeasible 2004 Ford F250 Pickup Fire 2 5,000 Y 2004 Ford Expedition SUV FIRE 8 0 Y 2001 FORD SUV 4X4 SUV FIRE 4 yes 2002 Freightliner Fire Truck Truck FIRE 3 189,500 Y N Unfeasible N 1988 Seagrave Fire Truck Truck FIRE DEPT.4 200,000 Y N Unfeasible N 1991 Ford Rescue/LM800 Truck FIRE DEPT.2 300 Y N ?N 1998 Pierce Fire Truck Truck FIRE DEPT.5 175,000 Y N Unfeasible N 1987 Ford Water Tanker Truck FIRE DEPT.2 84,000 Y N Unfeasible N 1983 International Truck Truck FIRE/EMERGENCY 3 50,000 Y N Critical 1934 Ford Fire Truck Truck FIRE/PARADES 2 5,000 Y N Unfeasible N 1994 Stutz 16' Skiff w/ Mercury 40 hp OB Boat HARBOR 0 N N NA N 1982 Stutz 16' Skiff w/ 2009 Mercury 60 hp OB Boat HARBOR 0 N 1995 Ford Pickup HARBOR 3 5,000 N 2009 Ford F350 Pickup HARBOR 2 0 N 2009 Ford F350 Pickup Harbor 2 0 N 2007 Ford F350 Truck HARBOR 3 0 N 1977 Chevrolet Van Van, Pass HARBOR MAINT.2 1,000 N Artic Cat 366 ATV ATV harbor-snow plowing 1 5000 yes N Yamaha ATV ATV harbor-snow plowing 1 5000 yes N 2011 Ford F250 Super Duty Pickup Light Dept 3 20,560 N 1989 Chevrolet S10 Pickup LINE DEPT.2 1,000 N 2003 Ford Pickup LINE DEPT.3 20,000 N 2010 BROOKS BROS.TRAILER Trailer LINE DEPT.NO N N 2008 Ford Line Truck Truck LINE DEPT.3 110,000 Y N Unfeasible N 1999 International 4800 Digger Derrik Truck LINE DEPT.2 65,000 Y N ?N 2000 International Line Truck Truck LINE DEPT.3 20,000 Y 1986 Chevrolet S-10 Pickup PARKS DEPT.2 0 2007 Yamaha GRIZZLY ATV POLICE 1 YES N N 2007 Yamaha GRIZZLY ATV POLICE 1 YES N N 1999 Ford CVP 4-door car Car POLICE 3 8,000 N 2008 Ford Crown Victoria Car POLICE 6 27,000 N N 2008 Ford Crown Victoria Car POLICE 6 27,000 N N 2006 Ford Crown Victoria Car POLICE 5 26,303 N 2008 Ford F350 Super Cab Pickup Police 6 30,000 N N 2001 Ford Expedition SUV POLICE 5 0 2007 Tarnell Full Trailer Trailer POLICE 0 N N NA N 2008 Ford F550 Truck POLICE 3 46,394 N N 2002 Dodge Durango Truck Police 2 0 N 1983 Chevrolet Camaro Pickup Police, DARE 5 1,000 N 2004 Ford Pickup Power&Light Co 2 20,000 N 2000 Ford Crown Victoria 4-door car Car Public Works 5 10,000 N 1993 CHEVY PU Pickup PUBLIC WORKS 3 NO 1979 FORD PU Pickup PUBLIC WORKS 3 NO 1994 FORD PU Pickup PUBLIC WORKS 3 NO 1996 GMC PU Pickup PUBLIC WORKS 3 NO 1990 Ford Pickup Public Works 3 2,000 N 1992 Ford Pickup Public Works 3 3,000 N 1995 Ford 3/4 Ton Pickup Public Works 3 5,750 N 1997 Ford F350 Pickup Public Works 3 10,000 N 1997 Chevrolet Pickup Public Works 3 0 2007 Ford F550 Super Duty Pickup Public Works 3 0 N 2009 Ford F250 Pickup Public Works 2 0 N 1996 FORD BRONCO SUV PUBLIC WORKS 4 NO 2009 Elgin Street Sweeper Truck Public Works 2 0 N N Unfeasible N 1983 Mack Dump Truck Truck Public Works 2 10,000 Y 1991 Freightliner Water Truck Truck Public Works 2 15,000 Y 2010 Freightliner Model M2 Garbage Truck Truck SANITATION 3 150,000 N N Unfeasible N 2010 Freightliner Model M2 Garbage Truck Truck SANITATION 3 150,000 N N Unfeasible N 1994 Chevrolet Suburban Van, Pass WATER DEPT.5 31,000 N 2012 Artic Cat 450 ATV Water Treatment plt.1 1 5000 YES N N City and Borough of Wrangell Alaska Existing Vehicle Fleet Analysis - Sort by TYPE by WHPacific, Inc. 4/19/2013 Page 1 of 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 A B C D E F H L O P Q Model Year Make Model Body Type Use # of Seats Insured Value Is Vehicle Garaged? Likely EV Candidate?Reasons Likely PHEV Candidate? 2003 Ford Ambulance Ambulance FIRE 2 115,000 Y N Unfeasible 2008 Ford F450 4x4 Ambulance Ambulance FIRE 110,000 Y N Unfeasible Artic Cat 366 ATV ATV harbor-snow plowing 1 5000 yes N Yamaha ATV ATV harbor-snow plowing 1 5000 yes N 2007 Yamaha GRIZZLY ATV POLICE 1 YES N N 2007 Yamaha GRIZZLY ATV POLICE 1 YES N N 2012 Artic Cat 450 ATV Water Treatment plt.1 1 5000 YES N N 1994 Stutz 16' Skiff w/ Mercury 40 hp OB Boat HARBOR 0 N N NA N 1982 Stutz 16' Skiff w/ 2009 Mercury 60 hp OB Boat HARBOR 0 N 1999 Ford CVP 4-door car Car POLICE 3 8,000 N 2000 Ford Crown Victoria 4-door car Car Public Works 5 10,000 N 2008 Ford Crown Victoria Car POLICE 6 27,000 N N 2008 Ford Crown Victoria Car POLICE 6 27,000 N N 2006 Ford Crown Victoria Car POLICE 5 26,303 N 1993 CHEVY PU Pickup PUBLIC WORKS 3 NO 1979 FORD PU Pickup PUBLIC WORKS 3 NO 1994 FORD PU Pickup PUBLIC WORKS 3 NO 1996 GMC PU Pickup PUBLIC WORKS 3 NO 2004 Ford F250 Pickup Fire 2 5,000 Y 1995 Ford Pickup HARBOR 3 5,000 N 2009 Ford F350 Pickup HARBOR 2 0 N 2009 Ford F350 Pickup Harbor 2 0 N 2011 Ford F250 Super Duty Pickup Light Dept 3 20,560 N 1989 Chevrolet S10 Pickup LINE DEPT.2 1,000 N 2003 Ford Pickup LINE DEPT.3 20,000 N 1986 Chevrolet S-10 Pickup PARKS DEPT.2 0 2008 Ford F350 Super Cab Pickup Police 6 30,000 N N 1983 Chevrolet Camaro Pickup Police, DARE 5 1,000 N 2004 Ford Pickup Power&Light Co 2 20,000 N 1990 Ford Pickup Public Works 3 2,000 N 1992 Ford Pickup Public Works 3 3,000 N 1995 Ford 3/4 Ton Pickup Public Works 3 5,750 N 1997 Ford F350 Pickup Public Works 3 10,000 N 1997 Chevrolet Pickup Public Works 3 0 2007 Ford F550 Super Duty Pickup Public Works 3 0 N 2009 Ford F250 Pickup Public Works 2 0 N 2001 Ford Expedition SUV POLICE 5 0 2004 Ford Expedition SUV FIRE 8 0 Y 2001 FORD SUV 4X4 SUV FIRE 4 yes 1996 FORD BRONCO SUV PUBLIC WORKS 4 NO 2010 BROOKS BROS.TRAILER Trailer LINE DEPT.NO N N 2007 Tarnell Full Trailer Trailer POLICE 0 N N NA N 2008 Ford Line Truck Truck LINE DEPT.3 110,000 Y N Unfeasible N 2008 Ford F550 Truck POLICE 3 46,394 N N 2009 Elgin Street Sweeper Truck Public Works 2 0 N N Unfeasible N 1934 Ford Fire Truck Truck FIRE/PARADES 2 5,000 Y N Unfeasible N 2002 Freightliner Fire Truck Truck FIRE 3 189,500 Y N Unfeasible N 1988 Seagrave Fire Truck Truck FIRE DEPT.4 200,000 Y N Unfeasible N 1991 Ford Rescue/LM800 Truck FIRE DEPT.2 300 Y N ?N 1998 Pierce Fire Truck Truck FIRE DEPT.5 175,000 Y N Unfeasible N 1983 International Truck Truck FIRE/EMERGENCY 3 50,000 Y N Critical 2007 Ford F350 Truck HARBOR 3 0 N 2010 Freightliner Model M2 Garbage Truck Truck SANITATION 3 150,000 N N Unfeasible N 2010 Freightliner Model M2 Garbage Truck Truck SANITATION 3 150,000 N N Unfeasible N 1983 Mack Dump Truck Truck Public Works 2 10,000 Y 1984 GMC Line Truck Truck ELECTRICAL DEPT.3 5,000 Y 1999 International 4800 Digger Derrik Truck LINE DEPT.2 65,000 Y N ?N 2000 International Line Truck Truck LINE DEPT.3 20,000 Y 2002 Dodge Durango Truck Police 2 0 N 1987 Ford Water Tanker Truck FIRE DEPT.2 84,000 Y N Unfeasible N 1991 Freightliner Water Truck Truck Public Works 2 15,000 Y 1986 Buick Hearse Van, Cargo 5 13,000 Y 1995 Ford Explorer Van, Pass City Admin 5 6,250 N 1977 Chevrolet Van Van, Pass HARBOR MAINT.2 1,000 N 1994 Chevrolet Suburban Van, Pass WATER DEPT.5 31,000 N City and Borough of Wrangell Alaska Existing Vehicle Fleet Analysis - Sort by YEAR by WHPacific, Inc. 4/19/2013 Page 1 of 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 A B C D E F H L O P Q Model Year Make Model Body Type Use # of Seats Insured Value Is Vehicle Garaged? Likely EV Candidate?Reasons Likely PHEV Candidate? 2012 Artic Cat 450 ATV Water Treatment plt.1 1 5000 YES N N 2011 Ford F250 Super Duty Pickup Light Dept 3 20560 N 2010 Freightliner Model M2 Garbage Truck Truck SANITATION 3 150000 N N Unfeasible N 2010 Freightliner Model M2 Garbage Truck Truck SANITATION 3 150000 N N Unfeasible N 2010 BROOKS BROS.TRAILER Trailer LINE DEPT.NO N N 2009 Ford F350 Pickup HARBOR 2 0 N 2009 Ford F350 Pickup Harbor 2 0 N 2009 Ford F250 Pickup Public Works 2 0 N 2009 Elgin Street Sweeper Truck Public Works 2 0 N N Unfeasible N 2008 Ford F450 4x4 Ambulance Ambulance FIRE 110000 Y N Unfeasible 2008 Ford Line Truck Truck LINE DEPT.3 110000 Y N Unfeasible N 2008 Ford F550 Truck POLICE 3 46394 N N 2008 Ford F350 Super Cab Pickup Police 6 30000 N N 2008 Ford Crown Victoria Car POLICE 6 27000 N N 2008 Ford Crown Victoria Car POLICE 6 27000 N N 2007 Ford F550 Super Duty Pickup Public Works 3 0 N 2007 Tarnell Full Trailer Trailer POLICE 0 N N NA N 2007 Ford F350 Truck HARBOR 3 0 N 2007 Yamaha GRIZZLY ATV POLICE 1 YES N N 2007 Yamaha GRIZZLY ATV POLICE 1 YES N N 2006 Ford Crown Victoria Car POLICE 5 26303 N 2004 Ford Pickup Power&Light Co 2 20000 N 2004 Ford F250 Pickup Fire 2 5000 Y 2004 Ford Expedition SUV FIRE 8 0 Y 2003 Ford Ambulance Ambulance FIRE 2 115000 Y N Unfeasible 2003 Ford Pickup LINE DEPT.3 20000 N 2002 Freightliner Fire Truck Truck FIRE 3 189500 Y N Unfeasible N 2002 Dodge Durango Truck Police 2 0 N 2001 Ford Expedition SUV POLICE 5 0 2001 FORD SUV 4X4 SUV FIRE 4 yes 2000 International Line Truck Truck LINE DEPT.3 20000 Y 2000 Ford Crown Victoria 4-door car Car Public Works 5 10000 N 1999 International 4800 Digger Derrik Truck LINE DEPT.2 65000 Y N ?N 1999 Ford CVP 4-door car Car POLICE 3 8000 N 1998 Pierce Fire Truck Truck FIRE DEPT.5 175000 Y N Unfeasible N 1997 Ford F350 Pickup Public Works 3 10000 N 1997 Chevrolet Pickup Public Works 3 0 1996 GMC PU Pickup PUBLIC WORKS 3 NO 1996 FORD BRONCO SUV PUBLIC WORKS 4 NO 1995 Ford Explorer Van, Pass City Admin 5 6250 N 1995 Ford 3/4 Ton Pickup Public Works 3 5750 N 1995 Ford Pickup HARBOR 3 5000 N 1994 Chevrolet Suburban Van, Pass WATER DEPT.5 31000 N 1994 Stutz 16' Skiff w/ Mercury 40 hp OB Boat HARBOR 0 N N NA N 1994 FORD PU Pickup PUBLIC WORKS 3 NO 1993 CHEVY PU Pickup PUBLIC WORKS 3 NO 1992 Ford Pickup Public Works 3 3000 N 1991 Freightliner Water Truck Truck Public Works 2 15000 Y 1991 Ford Rescue/LM800 Truck FIRE DEPT.2 300 Y N ?N 1990 Ford Pickup Public Works 3 2000 N 1989 Chevrolet S10 Pickup LINE DEPT.2 1000 N 1988 Seagrave Fire Truck Truck FIRE DEPT.4 200000 Y N Unfeasible N 1987 Ford Water Tanker Truck FIRE DEPT.2 84000 Y N Unfeasible N 1986 Buick Hearse Van, Cargo 5 13000 Y 1986 Chevrolet S-10 Pickup PARKS DEPT.2 0 1984 GMC Line Truck Truck ELECTRICAL DEPT.3 5000 Y 1983 International Truck Truck FIRE/EMERGENCY 3 50000 Y N Critical 1983 Mack Dump Truck Truck Public Works 2 10000 Y 1983 Chevrolet Camaro Pickup Police, DARE 5 1000 N 1982 Stutz 16' Skiff w/ 2009 Mercury 60 hp OB Boat HARBOR 0 N 1979 FORD PU Pickup PUBLIC WORKS 3 NO 1977 Chevrolet Van Van, Pass HARBOR MAINT.2 1000 N 1934 Ford Fire Truck Truck FIRE/PARADES 2 5000 Y N Unfeasible N Artic Cat 366 ATV ATV harbor-snow plowing 1 5000 yes N Yamaha ATV ATV harbor-snow plowing 1 5000 yes N City and Borough of Wrangell Alaska Existing Vehicle Fleet Analysis - Sort by CANDIDATE by WHPacific, Inc. 4/19/2013 Page 1 of 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 A B C D E F H L O P Q Model Year Make Model Body Type Use # of Seats Insured Value Is Vehicle Garaged? Likely EV Candidate?Reasons Likely PHEV Candidate? 2003 Ford Ambulance Ambulance FIRE 2 115,000 Y N Unfeasible 2008 Ford F450 4x4 Ambulance Ambulance FIRE 110,000 Y N Unfeasible Artic Cat 366 ATV ATV harbor-snow plowing 1 5000 yes N Yamaha ATV ATV harbor-snow plowing 1 5000 yes N 2007 Yamaha GRIZZLY ATV POLICE 1 YES N N 2007 Yamaha GRIZZLY ATV POLICE 1 YES N N 2012 Artic Cat 450 ATV Water Treatment plt.1 1 5000 YES N N 1994 Stutz 16' Skiff w/ Mercury 40 hp OB Boat HARBOR 0 N N NA N 2008 Ford Crown Victoria Car POLICE 6 27,000 N N 2008 Ford Crown Victoria Car POLICE 6 27,000 N N 2008 Ford F350 Super Cab Pickup Police 6 30,000 N N 2010 BROOKS BROS.TRAILER Trailer LINE DEPT.NO N N 2007 Tarnell Full Trailer Trailer POLICE 0 N N NA N 2008 Ford Line Truck Truck LINE DEPT.3 110,000 Y N Unfeasible N 2008 Ford F550 Truck POLICE 3 46,394 N N 2009 Elgin Street Sweeper Truck Public Works 2 0 N N Unfeasible N 1934 Ford Fire Truck Truck FIRE/PARADES 2 5,000 Y N Unfeasible N 2002 Freightliner Fire Truck Truck FIRE 3 189,500 Y N Unfeasible N 1988 Seagrave Fire Truck Truck FIRE DEPT.4 200,000 Y N Unfeasible N 1991 Ford Rescue/LM800 Truck FIRE DEPT.2 300 Y N ?N 1998 Pierce Fire Truck Truck FIRE DEPT.5 175,000 Y N Unfeasible N 1983 International Truck Truck FIRE/EMERGENCY 3 50,000 Y N Critical 2010 Freightliner Model M2 Garbage Truck Truck SANITATION 3 150,000 N N Unfeasible N 2010 Freightliner Model M2 Garbage Truck Truck SANITATION 3 150,000 N N Unfeasible N 1999 International 4800 Digger Derrik Truck LINE DEPT.2 65,000 Y N ?N 1987 Ford Water Tanker Truck FIRE DEPT.2 84,000 Y N Unfeasible N 1982 Stutz 16' Skiff w/ 2009 Mercury 60 hp OB Boat HARBOR 0 N N Unfeasible N 1999 Ford CVP 4-door car Car POLICE 3 8,000 N 2000 Ford Crown Victoria 4-door car Car Public Works 5 10,000 N 2006 Ford Crown Victoria Car POLICE 5 26,303 N 1993 CHEVY PU Pickup PUBLIC WORKS 3 NO 1979 FORD PU Pickup PUBLIC WORKS 3 NO 1994 FORD PU Pickup PUBLIC WORKS 3 NO 1996 GMC PU Pickup PUBLIC WORKS 3 NO 2004 Ford F250 Pickup Fire 2 5,000 Y 1995 Ford Pickup HARBOR 3 5,000 N 2009 Ford F350 Pickup HARBOR 2 0 N 2009 Ford F350 Pickup Harbor 2 0 N 2011 Ford F250 Super Duty Pickup Light Dept 3 20,560 N 1989 Chevrolet S10 Pickup LINE DEPT.2 1,000 N 2003 Ford Pickup LINE DEPT.3 20,000 N 1986 Chevrolet S-10 Pickup PARKS DEPT.2 0 1983 Chevrolet Camaro Pickup Police, DARE 5 1,000 N 2004 Ford Pickup Power&Light Co 2 20,000 N 1990 Ford Pickup Public Works 3 2,000 N 1992 Ford Pickup Public Works 3 3,000 N 1995 Ford 3/4 Ton Pickup Public Works 3 5,750 N 1997 Ford F350 Pickup Public Works 3 10,000 N 1997 Chevrolet Pickup Public Works 3 0 2007 Ford F550 Super Duty Pickup Public Works 3 0 N 2009 Ford F250 Pickup Public Works 2 0 N 2001 Ford Expedition SUV POLICE 5 0 2004 Ford Expedition SUV FIRE 8 0 Y 2001 FORD SUV 4X4 SUV FIRE 4 yes 1996 FORD BRONCO SUV PUBLIC WORKS 4 NO 2007 Ford F350 Truck HARBOR 3 0 N 1983 Mack Dump Truck Truck Public Works 2 10,000 Y 1984 GMC Line Truck Truck ELECTRICAL DEPT.3 5,000 Y 2000 International Line Truck Truck LINE DEPT.3 20,000 Y 2002 Dodge Durango Truck Police 2 0 N 1991 Freightliner Water Truck Truck Public Works 2 15,000 Y 1986 Buick Hearse Van, Cargo 5 13,000 Y 1995 Ford Explorer Van, Pass City Admin 5 6,250 N 1977 Chevrolet Van Van, Pass HARBOR MAINT.2 1,000 N 1994 Chevrolet Suburban Van, Pass WATER DEPT.5 31,000 N Appendix B. Manufacturer Information New York's Police Department Buys 50 Chevy Volts The City of New York will buy 50 new Chevrolet Volts as part of an effort to combat pollution and gas usage within the city. The Volt is now the first electric car to be used by the New York Police Department. The city also plans to purchase 20 additional electric vehicles, including a battery-powered version of Ford's Transit Connect transport van. New York now has largest municipal electric fleet in the country. The purchase of these 70 electric vehicles is part of New York's 'PlaNYC' program that aims to make the city a more sustainable and cleaner place to live. New York Mayor Mike Bloomberg released his own statement on the purchase. "We will continue to lead by example, but we also must provide New Yorkers with tools to make environmentally friendly choices in their own lives," Bloomberg said in the press release. "When provided with the facts, people become far more likely to choose an electric vehicle. Our job is to ensure the public has the facts, ensure they can make their own decisions and ensure that if they want to drive an electric vehicle, we are providing the infrastructure needed." Unlike most hybrid cars, the Volt primarily operates using its electric motor. When its batteries are drained, a gasoline motor works as an on-board power generator that keeps the main batteries alive. This layout has an advantage over a full electric drivetrains because the car can continue to run as long as there is gasoline in the tank. An owner can simply refill the tank if the batteries are depleted, and then recharge the car when it is most convenient. Encouraging the use of electric cars is a high priority for New York. In May, the city announced a plan to work with Nissan in order to produce an electric van that can replace the thousands of gasoline powered taxicabs buzzing around the city every day. Tweet 0 Share Email Print Tweet 0 Share Email Print J. MARK STERNBERG is an automotive journalist, car enthusiast and writer with a degree from the University of Arizona. Mark is a devoted Formula 1 fan and also enjoys boating, flying and attending the occasional track day. 1 1 Page 1 of 1New York's Police Department Buys 50 Chevy Volts -AutoTrader.com 4/29/2013http://www.autotrader.com/research/article/car-news/111007/new-yorks-police-department-buys-50-chev... Residential Business About Us Help Center My Account Billing/Payment Save Energy Start/Stop Service Problems/Safety Products/Programs Contact Us Cents for Energy Customer Choice Generate My Own Power GreenCurrents SmartCurrents SolarCurrents BioGreenGas Home Protection Plus Electric Products / Service Plug-In Electric Vehicles An Overview Get Plug-In Ready PEV Rates Charging Options Apply Now PEV Interactives PEV Calculator FAQs/Contact Us Gas Products / Service Community Events Powered by Google Search Register Sign In Customer Support DTE Energy Company Subsidiaries Special Topics Police/Fire | Large Businesses | Municipalities | Landlords | Builders | Careers | Privacy Policy | Terms & Conditions All contents © 2013 DTE Energy Company Page 1 of 1DTE Energy -Electric Vehicle Calculator 4/18/2013http://www.dteenergy.com/residentialCustomers/productsPrograms/electricVehicles/eVCalculator.html Residential Business About Us Help Center My Account Billing/Payment Save Energy Start/Stop Service Problems/Safety Products/Programs Contact Us Cents for Energy Customer Choice Generate My Own Power GreenCurrents SmartCurrents SolarCurrents BioGreenGas Home Protection Plus Electric Products / Service Plug-In Electric Vehicles An Overview Get Plug-In Ready PEV Rates Charging Options Apply Now PEV Interactives PEV Calculator FAQs/Contact Us Gas Products / Service Community Events Powered by Google Search Register Sign In Customer Support DTE Energy Company Subsidiaries Special Topics Police/Fire | Large Businesses | Municipalities | Landlords | Builders | Careers | Privacy Policy | Terms & Conditions All contents © 2013 DTE Energy Company Page 1 of 1DTE Energy -Electric Vehicle Calculator 4/18/2013http://www.dteenergy.com/residentialCustomers/productsPrograms/electricVehicles/eVCalculator.html Light Duty Vehicle ZERO EMISSIONS EVI’s Light Duty Vehicle, the eMega, can be customized for various applications. The eMega is capable of speeds up to 35mph. Vehicle options include CD stereo, heating and air conditioning, and right and left hand drive. The eMega comes standard with lithium iron phosphate batteries and a special drive train that has passed rigorous safety tests. The E-MEGA is your key to zero emission transportation. Applications Specifications BASIC SPECIFICATIONS Overall Length Overall Width Overall Height Ground Clearance Wheel Base Unladen Vehicle Weight Minimum Turning Radius Maximum Speed Climbing Ability Range Suspension (Front/Rear Wheel) Braking System (Front/Rear Wheel) 10.9 FT 5 FT 6 FT 7 IN 7.75 FT 1,350 LBS 19 FT Up to 35 MPH 22o Up To 50 Miles* McPherson-Strut Type Independent System Two Independent Circuits/Disc Type Hydraulic Brakes Supplementary Electromagnetic Brake For Automatic Hill-Hold Function and Parking Brake EVI-LD applications include: Parking Enforcement University Campuses Business Properties Security Facilities Management DRIVE TRAIN Motor Charger Battery 72V/21KW A/C 110V Standard Plug (7 Hour Charge) 76.8V/138 Ahr Valence Lithium Phosphate Lead Acid Batteries Available On Request Electric Vehicles International, LLC 1627 Army Court, Suite 1, Stockton, California 95206 T: 209.939.0405 | F: 209.939.0545 | info@evi-usa.com | www.EVI-USA.com *May vary based on applications, driver habits, and road conditions. Heavy-Duty PowerHeavy-Duty SavingSHeavy-Duty HybriD HybriDrive® Parallel available on crane carrier comPany'S let2 cHaSSiS: • Hybrid electric propulsion • Significant fuel and brake savings while reducing harmful emissions • Lower cost and weight alternative to other hybrid technologies • Onboard power plant for a path to future electrification of the vehicle body • Complements both diesel and CNG engines HybriDrive® — The Heavy-Duty Hybrid™ was specifically designed for the rugged demands of the refuse vocation. HybriDrive® Parallel benefits from the stop-and-go nature of refuse collection, uniquely delivering significant fuel savings without compromising payload. HybriDrive® Parallel, a hybrid electric propulsion system, provides high power and torque, and superior drivability all in a safe lighter-weight package than competing hybrid technologies. crane carrier HDP 700/750/800 Product System Hybrid # of PTOs Model Max power kW (Hp) Max torque Nm (ft-lb) Max power kW (Hp) Max torque Nm (ft-lb) HDP 600 260 (350) 1015 (750) 70 (94) 400 (295)1 HDP 700 260 (350) 1700 (1250) 70 (94) 400 (295)3 HDP 750 260 (350) 1700 (1250) 110 (145) 800 (590)3 HDP 800 400 (540) 2350 (1740) 110 (145) 800 (590)3 PROPULSION SYSTEMS ® tHree baSic comPonentS create a Significant fuel Saving SyStem BAE Systems’ HybriDrive® Parallel System is comprised of an Energy Storage System, Integrated Electronic Unit, and Integrated Drive Unit all working together in the most efficient manner to provide your vehicle with an average fuel economy improvement of 30 percent* (average based on vehicle track testing). energy Storage SyStem (eSS): Energy is captured during deceleration and stored into the battery system; that stored energy is later used during acceleration for fuel savings. Power from the ESS gives the vehicle a boost without consuming more fuel. The Energy Storage System uses the latest in technology—prismatic lithium-ion cells. This Lithium-ion technology was chosen by BAE Systems because it’s lighter, longer- lasting, easier to maintain, less expensive, and more efficient than competing battery alternatives. integrateD electronic unit (ieu): The Integrated Electronic Unit (IEU) is the control center and power inverter for the system. Based on the vehicle speed, the controls define when power is drawn from the batteries to supplement the conventional drive train, and efficiently blends this added power to provide optimum fuel usage. The IEU also controls the system to optimally store energy during deceleration, not only conserving energy but providing brake savings. integrateD Drive unit (iDu): The Integrated Drive Unit consists of a motor/generator and a hybrid transmission. The IDU takes its direction from the IEU to blend the engine and electric machine torque, maintaining the most efficient engine speed during acceleration events. Once the vehicle is up to speed and operating efficiently, the electrical power is phased out. As the vehicle decelerates, the energy is captured via the generator and stored in the ESS for the fore-mentioned use. Save fuel witH engine off: For additional fuel and emissions savings, the HybriDrive® system has an efficient “engine stop/start” capability. When the vehicle is at an idle position, the IEU signals the engine to power off to eliminate this unnecessary fuel consumption. BAE Systems is a world leader in the design and production of hybrid electric technology. With more than 500 million miles of revenue service, more than 33 million gallons of fuel saved, and more than 460,000 tons of carbon dioxide emission prevented, the market- leading HybriDrive Series System has proven itself to be one of the most efficient hybrid systems for the transit bus sector. HybriDrive series and parallel technologies both use simplified and proven components and controls to delivery its capabilities. Learn more at www.hybridrive.com Glen Pochocki Crane Carrier Company 1925 N. Sheridan Rd. Tulsa, OK 74115 918-836-1651 gapochocki@cranecarrier.com www.cranecarrier.com Larry Fuehrer BAE Systems HybriDrive Solutions Apt 1006 1480 Gulf Blvd Clearwater, FL 33767 Larry.fuehrer@baesystems.com www.hybridrive.com aSk uS to eStimate your oPerational coSt SavingS contact uS toDay: This document gives only a general description of products and services and except where expressly provided otherwise shall not form part of any contract. From time to time, changes may be made in the products or conditions of supply. Published work © 2012 BAE SYSTEMS. All rights reserved. BAE SYSTEMS is a registered trade mark of BAE Systems plc. 4.12.DA © 2011 All rights reserved. Litho USA. L752 11/11For More Information Contact:CORPORATE HEADQUARTERS4420 NW 14th AvenueSeattle, WA 98107Toll Free: 1-800-762-0165info@northern-lights.comNORTHEAST BRANCH OFFICE8 Connector RoadAndover, MA 01810Toll Free: 1-800-480-4223SOUTHEAST BRANCH OFFICE1419 W. Newport Center DriveDeerfi eld Beach, FL 33442Toll Free: 1-800-843-6140Founded in 1958, Northern Lights, Inc. is a leading manufacturer of marine-diesel generators, Lugger propulsion engines and Technicold marine systems. The company’s products are distributed through a global sales and service network to over 40 countries. Northern Lights manufactures a line of rugged Lugger propulsion engines, 40 to 525 Horsepower. Proven in commercial fi shing boats, high-mileage trawlers and high-performance yachts, Northern Lights products provide unmatched quality and reliability.Huron Campus1098 Clark StreetEndicott, NY 13766607.761.5728www.northern-lights.comwww.hybridrive.comPROPULSION SYSTEMS® HybriDrive® Marine Systems provide clean, reliable power with world classcomponents. Based on a tested, reliable Lugger propulsion engine and a traction generator, energy is held in a series of battery packs and metered through a power control system. The traction motor provides power to the prop, while energy is stored for its most effi cient usage. Available in 3 phase, 60 or 50 Hertz confi gurations, the amount of power produced and stored can be customized to fit your vessel’s requirements. The entire package is designed to be clean, quiet, environmentally responsible and will reduce both energy waste and fuel costs as soon as its installed.HybriDrive® Marine System is the result of the collaboration between BAE Systems, anindustry leading manufacturer of hybrid power and control systems; and Northern Lights, an internationally known provider of marine power and propulsion.The result of our combined knowledge, experience and expertise, HybriDrive® Marine provides a highly reliable, versatile and green solution to the marine environment.• The engine operates at its optimal fuelcurve at all times. The system helps ensure that load demand is met without over or underloading your ship’s power supply.• Maximum fuel effi ciency.• Designed for continous dutyoperation.• Reduces engine usage.• Lowers maintenancerequirements.• Proven reliability.• Reliable, durable, simple to use. propulsion from a trusted name in marine manufacturing.• Proven hybrid components with millionsof trouble-free operational hours of commercial service.• Sealed electric components require noservice with substantially reduced maintenance requirements.• Modular component replacement if needed.Optimized Engine Performance-Optimized Components-• Tested in harsh on-road environments, where continuous duty is the norm, the hybrid marine system has saved 10 million gallons of diesel fuel.Fuel Effi cient -• Meeting or exceeding all current emission standards, Lugger and hybrid technology ensure minimal impact to the environment where commercial boats operate.Clean Operation -INTRODUCING THE HYBRID MARINE SYSTEM BY NORTHERN LIGHTSA SIMPLE, ROBUST PROPULSION SYSTEM – WITH HYBRID TECHNOLOGYTOP QUALITY ENGINE AND COMPONENT SYSTEMS FROM INDUSTRY LEADERSCLEAN, EFFICIENT, RELIABLE - BENEFITS OF THE HYBRID MARINE SYSTEM• Marine propulsion from a trusted name in the industry, packaged with the state of the art in proven hybrid technology for unmatched durability.Reliable Performance -• Design the system for electric propulsion only, for electric propulsion with ship board power, or to power all of your vessel’s equipment and machinery.Flexible Architecture - Powered by Cars.com. Home Buy or Sell a Truck Forums Reviews News Special Reports Driven: Protean Ford F-150 All-Electric Pickup Truck Posted by Mike Levine | May 12, 2011 Words and Photos by Ben Wojdyla for PickupTrucks.com It might not seem obvious, but pickup trucks are the ideal candidates for electric drive systems. Electric motors deliver peak torque at zero rpm to get big loads moving. There’s plenty of room to store massive batteries and heavy-duty components can handle their extra weight. It’s why Protean Electric –formerly known as PML Flightlink – converted a 2009 Ford F-150 to all-electric drive for the 2008 SEMA show. The unique part: Unlike normal EVs, Protean’s F-150 has in-wheel electric motors, four of 'em, and boy are they powerful. How do we know? Because after three years, we finally got behind the wheel of this alt-powered truck. Let's back up a moment, though. In-wheel electric motors on trucks aren't a new idea. In fact, one of the first hybrid vehicles was a modified truck built in 1900 by Ferdinand Porsche, and it used so-called pancake motors in the wheels. The reason then is the same as the reason now — mechanical simplicity and packaging advantages. Putting electric motors in the wheels makes sense on a basic level; it puts the power-generating elements where power is needed and frees up space for passengers and cargo. Browse News By: Category Aftermarket Auto Shows Awards Compact/Midsize Custom Trucks Diesels Fuel Economy Full-Size Heavy-Duty Hybrids Interiors Light-Duty New Trucks Powertrains Pricing Safety Spy Photos Sources Say Towing and Hauling Manufacturer Truck Shopping Tools Search for New & Used Find a Dealer See Hottest Truck Deals List your Truck for Sale Read Expert Reviews Review Your Own Truck Recent Posts Reid Bigland Gets Top Spot at Ram Spied! HD Pickups Show Tailpipe Changes Ram Truck CEO Moves to Nissan USA Truck Repair Costs Are on the Rise SearchSearch PickupTrucks: Page 1 of 15Driven: Protean Ford F-150 All-Electric Pickup Truck -PickupTrucks.com News 4/15/2013http://news.pickuptrucks.com/2011/05/driven-protean-ford-f-150-all-electric-pickup-truck.html Looking from the rear forward. Note the hollow beam rear axle shackled to conventional leaf springs and lack of a rear differential. Gear reduction and wheel speed is controlled inside each wheel motor. Battery packs and power cables (orange) are also shown. Until recently, the biggest reason against using in-wheel motors was that they create too much unsprung weight. Unsprung weight is generally considered the enemy of handling performance. The more weight hanging off the end of the suspension, the harder it is to control the motion of the wheel and by extension, the performance of the vehicle. Generally, more power from an electric motor requires more windings, bigger permanent magnets and added weight. Protean has taken a different approach that not only increases power, it improves reliability, control and, most importantly, reduces weight. Protean created an in-wheel electric motor unit that's essentially eight motors in one package. Inside the motor, its rotor looks conventional, with segmented permanent magnets on the outside. The stator, however, is new. Arranged in a circle are eight identical inverter motor controllers, each capable of switching on and off independently and driving the motor at low power individually. Alone, they offer minimum power use, but all together, they switch on and off to provide maximum power and torque. Closeup look at the right front wheel. Protean's in-wheel electric motor has minimal impact on the independent front suspension, knuckles and tie rods. This system provides several important benefits, including easy repair and redundancy. But most important is the weight reduction the design allows. Each motor tips the scales around 68 pounds, more than a brake and half-shaft system, but still manageable from a vehicle tuning and dynamics perspective. Protean has designed its motors as a modular bolt-on system. The motors are designed to use the factory bearing systems, so installation means removing the factory brake system, swapping the bearing onto the integrated mechanical brake/motor unit and bolting it back into place on the axle. Recall Alert: Airbag Problem Affects Millions of Toyota, Honda, Nissan and Mazda Vehicles Read recent stories Read older stories Latest User Comments Frank on Reid Bigland Gets Top Spot at Ram Big Al from Oz on Reid Bigland Gets Top Spot at Ram 2016 Power Wagon on Reid Bigland Gets Top Spot at Ram Papa Jim on Reid Bigland Gets Top Spot at Ram 2016 Power Wagon on Reid Bigland Gets Top Spot at Ram Subscribe Page 2 of 15Driven: Protean Ford F-150 All-Electric Pickup Truck -PickupTrucks.com News 4/15/2013http://news.pickuptrucks.com/2011/05/driven-protean-ford-f-150-all-electric-pickup-truck.html A live axle like the solid rear axle a stock F-150 uses isn't necessary. To prove the point, Protean chucked the factory Ford rear axle in favor of a hollow beam axle, saving considerable weight in the process. They also ditched the rear differential because wheel speed and gear reduction is managed in each of the wheel motors. Protean’s demonstrator uses a slick inboard braking system much like an old Jaguar E-Type; however, the system can provide regenerative braking. Federal mandates require a mechanical backup system, so traditional hydraulic braking has been integrated into the latest motor design. How does such a radically different powertrain layout drive in a half-ton truck? A lot like today’s truck. As you might expect from an EV, power comes on strong from the start, and as you reach higher speed, the power output decreases. These aren’t weak motors. Each of the four can generate peak twist of 608 pounds-feet of torque, and continuous output is just as impressive at 368 pounds-feet. Remember, that's for each motor. Beastly as the motors might be, there’s still a major challenge to overcome: the battery, something Protean makes no bones about. Protean isn’t in the battery business, so the 40-kilowatt-hour battery installed under the bed isn't theirs, just the battery du jour. It's also the truck's weak point right now. Each motor can operate at 84 kwh peak power, about 112 hp, for a grand total of 448 hp. Unfortunately the battery can only output a maximum of 138 kW, or about 185 horsepower. So better battery means bigger power, just like better fuel pump means more fuel, means the potential for more power. Remember, though, that we're talking about a demonstration machine built three years ago. Battery technology has advanced a lot in that time, and so can performance. The interior has been customized with digital gauges and three push-button controls (next to cupholders) for drive, neutral and reverse modes. The large red button is a kill switch, just in case. But what about the handling? Making the case that in-wheel motors can be a viable drive system is tough, especially when pitching to a generation of chassis engineers taught that unsprung weight is the worst thing in the world. So Protean did something risky. It didn't tune the suspension at all after the conversion. To compensate for the removal of the drive line, the company placed the hefty battery pack to maintain proper weight distribution and ride height, and that's all it did. The truck still rides on the Page 3 of 15Driven: Protean Ford F-150 All-Electric Pickup Truck -PickupTrucks.com News 4/15/2013http://news.pickuptrucks.com/2011/05/driven-protean-ford-f-150-all-electric-pickup-truck.html factory springs and dampers front and rear. It's a tricky way to put the product to the ultimate test. With no suspension tuning working to Protean’s advantage, how does the truck perform compared with the stock setup? We're not going to gloss over the rougher ride, but considering the circumstances, we're open to believe Protean's view that previous unsprung weight concerns can be overcome. There is a noticeable increase in the amount of vibration translated to the driver compared with a stock truck. Some can be attributed to the 18-inch wheels and lower-profile tires, but in fairness, some comes from the added heft of the motors. It's not disconcerting, though, not even close. It's entirely within reason that with appropriate springs and dampers, you'd never know you were driving something other than a stock F-150, well, aside from the freaky quietness of the vehicle. Protean's in-wheel electric drive system had no problem moving the F-150 up and over a steep test grade. In a corner and at speed, it feels similar to a conventional pickup. Such a statement may seem generic, but it belies the possibilities of the system. The highest praise an EV or hybrid can ever get is, “It feels just like a normal vehicle.” That is oddly the goal. Do something revolutionary and make the difference imperceptible. In that measure, Protean has succeeded with this demo vehicle. What are the odds of this truck, or something like it, making it to production, considering the long odds facing upstart EV companies and their seemingly frequent burnout rate? Protean says it’s watertight financially, claiming it’s nearing its first contract to supply vehicles and has plenty of investor capital available. It expects to make an announcement in the near future of a U.S. production facility for its hardware. The F-150 demonstrator serves as a “most extreme case” of what Protean can deliver. The company plans to offer hybrid and all-electric vehicle solutions. Protean’s in-wheel system can operate as a through-the-road hybrid, a synchronous axle hybrid, all-electric as is the case with the F-150, or as selectively internal combustion and EV operation. Protean is currently a full generation ahead of the motors installed on this truck, with another generation pending release this summer. The numbers have changed slightly to improve continuous output and overall efficiency, with peak torque down to 578 pounds-feet and 355 pounds-feet continuous with continuous output up to 80 hp rather than 60 hp. After all this talk of kilowatts and inverter motor controllers and peak versus continuous output, the takeaway is this: Don't fear the future. As much as we all love big, powerful, dinosaur-fueled internal combustion engine-powered pickups, there's room enough for electric trucks, too, or even hybrids. If you think the growl of an IC engine is mandatory for the truck experience, just imagine what having 2,300 pounds-feet of torque on tap might do for your opinions. Page 4 of 15Driven: Protean Ford F-150 All-Electric Pickup Truck -PickupTrucks.com News 4/15/2013http://news.pickuptrucks.com/2011/05/driven-protean-ford-f-150-all-electric-pickup-truck.html Tiger Truck Industries Internationalg ELECTRIC VEHICLES 72vSPECIFICATIONSTiger Star Elc LSModel 578610-V, 72 Tiger Star X-CModel 57ab Elec LSV, 8640-72TiMoer Star Elec, del 367000Tiger Star Elec X-Cab, Model 364700Tiger Star Elec Crew Cab,Model 366700 Star Elec Cargo Van, Model 339700Star Elec Passenger Van, Model 370700Length (in.)152152152152152151151Width (in.)58.558.558.558.558.558.558.5Height (in.)71717171737777Ground Clearance (in.)7.57.57.57.57.57.57.5Inside Bed Length (in.)90.57190.5715588N/AInside Bed Width (in.)55.55455.5545446N/ABed Height (in.)131713171753N/AOutside Turning Radius (in.)182182182182182182182Wheel Base (in.)989898989892.592.5Empty Weight (lbs.)2,1202,1742,1202,1742,2962,5612,561Useful Load (lbs.) (incl. passengers)8808261,5821,5091,3831,5051,505Optional Overload Springs (lbs.)N/AN/A2,0322,0091,8331,9551,955Brakes, Hydraulic VacuumFront Disk/Rear DMechanical Arum BS Front Disk/RMechaniear Drum cal ABS Front MecDisk/Rear Drum hanical ABS Front Disk/Rear Drum Mechanical ABS Front Disk/Rear Drum Mechanical ABS Front Disk/Rear Drum Mechanical ABS Front Disk/Rear Drum Mechanical ABS Rear Axle Ratio5.145.145.145.145.145.145.14Motor Type8KW AC8KW AC8KW AC8KW AC8KW AC8KW AC8KW ACController72 Volt 550 Amp Programmable 72 Volt 550 Amp Programmable 72 Volt 550 Amp Programmable 72 Volt 550 Amp Programmable72 Volt 550 Amp Programmable 72 Volt 550 Amp Programmable 72 Volt 550 Amp ProgrammableSt Ch Smart Charger72 Volt On Board: Va72 Volt On Board: VaInput/Outpuriable 72 Volt On Boriable t72 Volt On BoInput/Oard: Variable 72 Volt Oard: Variable utput72 Volt OInn Board: Variable 72 Von Board: Variable put/Output72 Volt On Board: Variable lt On Board: Variable Input/Output72 Volt On Board: Variabl72 Volt On Board: VariablInput/Outpute 72 Volt On Board: Variable 72 Volt On Board: Variable e 72 Volt On Board: Variable Input/Output72 Volt On Board: Variable Input/OutputDrive Line Voltage72V72V72V72V72V72V72VChassis Voltage12 v negative ground12 v negative ground12 v negative ground12 v negative ground12 v negative ground12 v negative ground12 v negative ground Battery Pack Trojan 12756 x 12 Volt6 x 12 Volt6 x 12 Volt6 x 12 Volt6 x 12 Volt6 x 12 Volt6 x 12 VoltBattery Watering System*On BoardOn BoardOn BoardOn BoardOn BoardOn BoardOn Board* Includes Filler Hose W/RegulatorSeasoned Battery Best RangeLoaded 1,000 lbsMailman RouteData48 miles26 miles18 milesMaximum SpeedDrive UnitGradabilityBatteriesController25 mph72V / AC22%6 - 12 voltSolid State:pam 72V Electric Specs9-13-12.xls/72V Electrics Appendix C. EV Resource ,QIRUPDWLRQ Shift the Power The Future is Here Electric vehicles have arrived. Are you ready to drive? Electric vehicle (EV) adoption is increasing and spreading throughout the state and the country. As of January 2013, over 80 Vermont communities have registered passenger EVs—a 213% increase since July 2012. Save Money • Spend the equivalent of $1 per gallon of gas to charge your vehicle • Save $1,200 or more on maintenance costs • Earn up to $7,500 in federal tax credits toward your purchase • …Or get a great lease deal through several Vermont dealers • Save even more through charging equipment tax credits Increased Convenience • Just plug in at night and wake up to a full charge each morning (no more trips to the gas pump!) • If needed, plug in at one of Vermont’s public charging stations to re-“fuel” during the day • Indulge in features typically seen only in luxury vehicles, such as navigation, Bluetooth, heated seats, heated steering wheels—even solar panels Great Performance • Accelerate faster than you would in most equivalent gas-powered cars • Expect increased traction due to heavy batteries (great for winter driving conditions) Great for Vermont • Increase our energy independence • Breathe deep—EVs produce zero tailpipe emissions • Emit less pollutants than you would driving a gasoline-powered vehicle (even factoring in manufacturing and electricity usage emissions) • Reduce noise pollution (EVs are incredibly quiet) For more information on EVs in Vermont, visit www.driveelectricvt.com. TYPES OF EVS All Electric Vehicle (AEV) also known as Battery Electric Vehicle (BEV): Powered solely by an electric battery Plug-in Hybrid Electric Vehicle (PHEV): Powered by an electric battery, and supplemented by conventional fuels (like gas or diesel) If all Vermont cars were electric, total annual energy costs would be 1/3 the $1.1 billion spent on petroleum fuels in 2010. The federal government offers tax credits up to $7,500 for buying an EV. Driving an EV is like paying $1/gallon of gas at the pump Drive Electric Vermont is a project of the Vermont Energy Investment Corporation (VEIC) in partnership with the State of Vermont, Project Get Ready, and a broad array of stakeholders advancing electric vehicle technology. How to Drive Electric... and Other FAQs on Electric Vehicles The future of transportation is here, and it’s knocking at your door! Our day-to-day means of transportation is changing, and the more munici- palities, business leaders, utilities and end-users know about Plug-in Electric Vehicles (PEVs), the more prepared they will be to embrace the “vehicles of tomorrow” today. Advanced Energy’s Electric Transportation sector is working to assist utilities, charging station vendors, municipali- ties and all initial stakeholders in understanding, planning for and implementing electric transportation initiatives. We’ve put together the follow- ing frequently asked questions about electric vehicles in an effort to help people drive electric! Q: When are the vehicles getting here? The Nissan Leaf and Chevy Volt are currently being sold in North Carolina. Additionally, there are several cities across the U.S. that have been slated as PEV “Hot Spots.” Vehicle manufacturers are targeting these cities for release of PEVs based on demographics and potential acceptance. As the influx of PEVs take place, surrounding municipali- ties and communities need to be prepared. The first mass-market PEVs sold in the U.S. have not been equally available throughout the nation. Automotive manufacturers like Chevrolet (General Motors), Ford, Nissan and Toyota have introduced their PEV models to larger communities that have made commitments to supporting PEVs. Manufacturers plan to expand into new markets in 2012 based on lessons learned in the initial rollout communities. Many models are presently available in select communities, such as the Triangle. Q: How far can they go? Most battery EVs can go about 100–200 miles before needing to be re- charged. Plug-in hybrid electric vehicles typically have smaller batteries and thus a shorter all-electric range. Q: How will the weather affect my vehicle range? Vehicle batteries are less efficient in cold weather. Electricity will also be needed to heat the passenger cabin and defrost or defog the windows, all of which will decrease the vehicle miles-traveled range. In hot weather, electricity will be needed for the air-conditioning system, but this requires less power than needed to accelerate the vehicle and maintain speed. Q: Who pays for putting the charging stations in? It depends on where the charging station is going. A PEV owner will have to pay to install a residential charging station. Many cities, towns, and electric utilities are offering subsidy programs for putting in charg- ing stations. There are also several grant projects aimed at subsidizing the installation cost for public and workplace charging stations, but ultimately it is up to public and corporate entities to put in their own charging stations. Vehicles Charging Stations – Costs, Location, Installation Q: Who pays for the electricity? It depends on where the charging station is located. In a residential setting, the homeowner will pay for their own electricity. In public settings, it is more complicated. In most states, it is illegal to resell electricity. Therefore, the owners of public charging stations must find an alternative way to recoup their costs. Some proposed ways of doing so include assessing a fee by the hour, charging a flat fee for access- ing the station, or requiring a subscription service to access the station. As volumes of vehicles are low, some public locations are offering free charging; however, as vehicle volumes increase this will likely not remain cost effective. Q: How much will I pay for electricity if I charge at home? During a day or a week, everyone will drive different distances and be in different traffic conditions, so it is very difficult to tell you how much energy you will use and put a dollar figure on it. In general, however, you will pay approximately $0.50 to $0.75 per equivalent gallon of gasoline that you would have used in your internal combustion car. This means that instead of paying approximately $35.00 for 10 gallons of gas to drive ~300 miles, you will pay somewhere between $5.00 and $7.50 for the electricity. Q: Where are charging stations going? Everywhere! Charging stations will be in your home if you own an electric vehicle, at public locations such as shopping malls, restaurants, airports, hotels and potentially at your workplace. Charging Stations – Costs, Location, Installation (cont.) Q: What about the needed infrastructure? Most charging will occur at the home, but we still need a robust public infrastructure to serve PEV owners who regularly travel long distances. Charging station locations can be found using the U.S. Department of Energy’s Charging Station Locator: www. afdc.energy.gov/afdc/fuels/ electricity_locations.html Q: How much do charging stations cost? For Level 2 stations, typical costs for a public station is $4000 to $10,000. Residential stations can range from under $1,000 for new construction to $2,000 for older homes (as older homes may require extensive electrical upgrades and wiring). Q: Can you recommend a charging station? While Advanced Energy does not recommend specific charging sta- tions, we have compiled information on many of the available charg- ing stations so end users can compare their options. Visit us at www. AdvancedEnergy.org and search for our Charging Station Technology Review web tool for more information. Q: Are the charge connectors safe? What happens if I touch the connector pins? The charge connectors are very safe. Each charging station and plug is required to have controls so that it will not be energized until it is plugged into a vehicle. If the plug is not connected to a vehicle, there will be no power to the connector pins. Q: Are these vehicles more susceptible to accidents? While lighter-weight vehicles are more susceptible to damage in an accident, all vehicles produced must meet the United States’ safety regulations and guidelines. They are no more susceptible to having an accident than a standard gasoline vehicle. Safety Q: Is the Jaws of Life strong enough to cut through new steel? First responder rescue equipment (“jaws of life”) are designed to cut through the heavy steel of current model vehicles, PEVs included. However, there are other safety factors that first responders should be aware of with regard to PEVs. There are multiple first responder courses in development for how to safely respond to emergencies associated with PEVs. Q: Will I be electrocuted if I plug in when it’s raining? No. There are many safeguards on the charging station, plug and vehicles that prevent this. Q: Will I get electrocuted if I drive into a ditch or pond? Electric and hybrid cars have been around for 10 to 15 years and have been exposed to rain, snow, road salt, heat, and humidity. In fact, every car you’ve ever driven contains a battery and an electrical system. Manufacturers have built in substantial security measures to prevent electricity-related injuries, so it is extremely unlikely that anyone would be electrocuted due to water submersion or a crash. How to Drive Electric... © 2011 Advanced Energy Corporation. All rights reserved. 11/11 Rev. 1 Q: What is the life of the battery? Current manufacturers are providing an eight- to 10 year warranty on the vehicle battery and it is expected to last significantly longer. There may be some capacity loss as time goes on, which is influenced by driving habits, weather, and other factors. Batteries Q: What is the cost of replacing the battery? As the total cost of the vehicle includes the battery pack, estimates on the cost of replacing the battery are not readily available. However, documentation has shown that most batteries will outlive the life of the car itself. As technology evolves, costs will continue to decline. Q: What do you do with spent batteries? Where do they go? Once the battery is no longer able to hold the level of charge needed to power the vehicle, owners should exchange the battery at a re-use/ recycling center. Re-using is very important because even when a lithium-ion vehicle battery is no longer able to function at a productive level within a vehicle, it still retains almost 80 percent of its original charging capacity. As such, batteries can be used for other applications requiring a lower level of performance. Research continues exploring options for the use of second-life electric vehicle batteries. Once the battery is no longer useful for lower performance tasks it will need to be properly discarded and recycled. As lithium is a highly recyclable material, recycled lithium can offset our overall lithium needs. Electricity Versus... Q: Are we trading oil dependence for lithium dependence? Nearly two-thirds of our imported petroleum is used for transpor- tation, and 76 percent of that is consumed by typical passenger vehicles. Since PEVs utilize a fuel source local to the U.S., replacing typical passenger vehicles with PEVs provides the U.S. with an oppor- tunity to make a significant decrease in foreign petroleum use, which translates to greater energy security. Our demand for lithium has been steadily increasing, and will continue to do so with the number of lithium-ion batteries needed for electric vehicles. However, experts expect lithium’s high level of recyclability to offset our demand. Q: Are we just extending the tail pipe? Isn’t it dirtier to run an electric vehicle? Is it really cleaner? PEVs that operate primarily in electric-only mode can provide many air quality benefits. However, pollutants emitted from electric power plants also must be taken into account. Argonne National Labora- tory’s Transportation Fuel-Cycle Model “GREET”** accounts for the complete lifecycle emissions of electric vehicles. The model reports that the use of PEVs reduces total greenhouse gas, CO, and VOC emissions, but PEVs actually can increase some overall emissions, such as SOx and NOx, particularly in rural areas. However, as electric power generation becomes cleaner, this increase in emissions is expected to decline. It is easier and less expensive to control the emissions of the 20,000 power plants in the United States than it is to control emissions of 250 million vehicles. **GREET: Greenhouse Gases Regulated Emissions and Energy Use in Transportation History Q: What happened to the electric car from the 1990s? What’s different this time around? Improved battery life, demand for an alternative to gasoline-powered vehicles, and consumer education and awareness has led to the resur- gence of interest in electric vehicles. In the 1990s one major obstacle to the adoption of PEVs was the amount of time it took to install a charging station – almost three months! Customers who purchased a PEV were unable to charge their vehicles at home until they installed their residential charging station, which required a permit. This was less than ideal and PEV manufacturers want to avoid making the same mistake again. As such, they are evaluating communities that are ac- tively addressing the permitting process as well as related local building codes. Another major problem was that there was no standard charging connector for all PEVs. This has been addressed for this generation of PEVs by a standard SAE J1772 charging protocol. ...and Other FAQs on Electric Vehicles © 2011 Advanced Energy Corporation. All rights reserved. 11/11 Rev. 1 Advanced Energy Corporation 909 Capability Drive, Suite 2100 Raleigh, NC 27606 919.857.9000 www.AdvancedEnergy.org How to Drive Electric... Resources Community Planning Guide Charging Station Installation Handbook for Electrical Contractors & Inspectors Charging Station Technology Review www.advancedenergy.org/transportation/resources U.S. Department of Energy’s Charging Station Locator www.afdc.energy.gov/afdc/fuels/electricity_locations.html Clean Cities Coalition Homepage www1.eere.energy.gov/cleancities/ Go Electric Drive: www.goelectricdrive.com/ Fuel Economy Comparisons www.fueleconomy.gov/ Leafing the Pump Behind: 12 Weeks with the Nissan Leaf www.advancedenergy.org/transportation/blog Argonne National Laboratory: Transportation Technology R&D Center www.greet.es.anl.gov/main HOME INDIVIDUALS GOVERNMENT BUSINESS ABOUT NEWS Resources List Search top Online Links to More Resources for PEVs and EVs Local Local Local Local InformationInformationInformationInformation Duke Energy Government Links U.S. Department of Energy Alternative Fuels and Advanced Vehicles Data Center (AFDC) About vehicles Public Charging Stations Map/Info Clean Cities Program Batteries National Renewable Energy Laboratory NREL Advanced Vehicles and Fuels Reesarch NREL Plug-In Hybrid Electric Vehicles NREL Fuel Cell Vehicles Argonne National Laboratory ANL: The Greenhouse Gases, Regulated Emissions, and Energy Use in Transportation (GREET) Model National Oceanic and Atmospheric Administration (NOAA) NOAA Annual Greenhouse Gas Index (AGGI) EV Carolina – list of local charging stations in South Carolina evcarolina.com Advocacy Efforts Go Electric Drive Association www.GoElectricdrive.com About Go4Pev Resources List Contact Readiness Actions to Date Page 1 of 4Resources List | go4pev.org 4/11/2013http://go4pev.org/about/resources-list/ HOME INDIVIDUALS GOVERNMENT BUSINESS ABOUT NEWS Electric Drive Transportation Association (EDTA) Industry association dedicated to advancing electric drive as a core technology on the road to sustainable mobility www.electricdrive.org The EV Project – US DOE and ECOtality www.theevproject.com Plug-in America California nonprofit electric vehicle advocacy organization www.pluginamerica.org Electric Power Research Institute Guide to Electric Vehicles www.epri.com Consumer Guide to Electric Vehicles EV World Promotes sustainable transportation with a focus on the people and policy, as well as technology www.evworld.com Electric Auto Association www.electricauto.org EAA Plug-in Hybrid Special Interest Group www.eaa-phev.org Project GetReady A non-profit initiative led by Rocky Mountain Institute, in conjunction with a wide array of partners and technical advisers. www.projectgetready.com Plug In Cars Community of automobile and PEV enthusiasts www.plugincars.com California Car Initiative To develop clean, efficient, and practical vehicles. CalCars.org Electric Cars are for Girls Page 2 of 4Resources List | go4pev.org 4/11/2013http://go4pev.org/about/resources-list/ HOME INDIVIDUALS GOVERNMENT BUSINESS ABOUT NEWS top top top top Local info and advocacy www.electric-cars-are-for-girls.com Laws on EVs, PHEVs and NEVs DOE Incentives and Laws DOE Alternative Fuels Data Center DOE Summaries of federal laws UCS hybrid center with state and federal law summaries and links California Air Resources Board: Laws and Regulations Community Resources for Owners by Make Tesla Motors Tesla Motors Club Forum (vBulletin) Unofficial Tesla Owners Map GM/Chevrolet GM-Volt.com (vBulletin) Nissan My Nissan Leaf Forum (phpBB) Ford Ford Focus Electric Forum (phpBB) News Sources for Electric Cars EV World online magazine Green Car Congress Megawatt Motorworks Electrifying Times EVCast, podcast for information on electric cars 4EVRiders, News, Blog, & Forum on Electric Cars and Plug-in Hybrids Page 3 of 4Resources List | go4pev.org 4/11/2013http://go4pev.org/about/resources-list/ HOME INDIVIDUALS GOVERNMENT BUSINESS ABOUT NEWS top EV Conversion Services & Components Ampmobile Conversions LLC.(EV conversions in South Carolina) ww.autoportinc.com (eBox conversions) Canadian Electric Vehicles Ltd.(EV conversions & components in BC) Cloud Electric Vehicles (Conversions, Supplies, Racing, Eboats+ in Clarksville, GA) Electric Vehicle Systems Conversions & Repair in New Underwood, SD Electric Motor Cars 713.729.8668 evman@dataline.net in TX ElectroAutomotive(EV kits & components, recent reports or slow deliveries, check with BBB) Electric Blue Motors Turn-key new car conversions. Electric Vehicles of America, Inc. EVs of America (EV kits & components) EV Components (Zillacontrollers and EV components) EVparts.com (EV components) NETGAIN (EV components) Hybrids Plus (PHEV conversions) KTA Services, INC.(EV kits & components) Metric Mind (EV components) REVOLT Custom Electric Vehicles (EV conversions and components in Austin, Texas) VoltsMobile (converter and EV repairs in WA) World Class Exotics © go4pev.org | All Rights Reserved topHome Individuals Business Government About Contact Admin Page 4 of 4Resources List | go4pev.org 4/11/2013http://go4pev.org/about/resources-list/ Electric Car Range in Cold Weather 4/10/2012 http://www.motherearthnews.com/ask-our-experts/electric-car-range-in-cold-weather-zb0z1204zmat.aspx By Jim Motavalli Where I live, we have bitterly cold winters. I’ve been told that electric cars don’t handle cold weather well. Is that true? Do some models do better than others? Electric car battery range is better in warmer climes, because in cold weather, chemical reactions happen more slowly. A drop of just 10 degrees Fahrenheit can sap 20 to 50 percent of a battery’s charge, depending on the system. According to Sherif Markaby, who directs Ford’s electrification program, batteries “are similar to people, as they both achieve maximum performance working under moderate, unchanged temperatures.” A warm battery can better accept charging from the regenerative braking system. Ford (for the Focus Electric) and GM (for the Volt) address this problem with a liquid temperature management system, which warms the battery pack as the car is charging. I drove the Volt during a chilly week in the cold winter of 2011, and traveled 28 miles before the gas engine kicked on to recharge the batteries. The Volt’s standard range is estimated to be 35 miles before it switches to gas power. Tony Williams, a San Diego-based Nissan Leaf owner, has created a range chart (see it at My Nissan Leaf) that is proving quite useful to other drivers of the all-electric car. According to Williams, at 70 degrees Fahrenheit, a Nissan Leaf with a full charge traveling at 55 mph will have 89 miles of range. But — and this is just one person’s experience — Williams’ calculations show that the car will lose 1 percent of range for every 2 degrees the temperature drops. For many drivers, that would translate into only 65 miles of real range available during a cold winter. Electric car battery range and performance isn’t the only issue in cold weather: Electric cars don’t have alternators to generate electricity. That means that the heater is a direct drain on the batteries — almost as dramatic as the drive motor itself. According to Williams, the Leaf’s heater can draw 1.5 to 3 kilowatt-hours (kwh) of electricity in an hour of use, and that’s a big dent when the battery stores only 24 kwh. Nissan estimates that at 14 degrees with the heater running, the Leaf’s range is 62 miles. Automakers are working on these problems. Their approach looks like a stopgap until a more efficient cabin heater is developed. Nissan introduced a standard cold-weather package for the 2012 Leaf that aims to reduce use of the climate control system with heated seats, a duct to direct warmth to the back seat, temperature management for the Page 1 of 2Mother Earth News Magazine 4/11/2013http://www.motherearthnews.com/print-article.aspx?id=2147501319 battery, and heated steering wheel and mirrors. Volt and Leaf owners can help their range by pre-warming the battery and the cabin while the car is plugged in. Patrick Wang, a Volt owner in the San Francisco area, saw his 40 miles of range drop to 34 miles when the temperature hit 40 degrees in northern California. His cold-weather driving tips include reducing cabin temperature to 68 and running the gas engine to warm up the cabin, then reverting to electric mode with the heater set to low. — Jim Motavalli, Author of High Voltage: The Fast Track to Plug In the Auto Industry Photo courtesy Tesla Motors Page 2 of 2Mother Earth News Magazine 4/11/2013http://www.motherearthnews.com/print-article.aspx?id=2147501319 ELECTRIC CAR MANUFACTURING'S MASSIVE CARBON FOOTPRINT by WYNTON HALL (/COLUMNISTS/WYNTON-HALL)11 Mar 2013 POST A COMMENT (/BIG-GOVERNMENT/2013/03/11/AVERAGE-ELECTRIC-CAR-PRODUCES-MORE-CARBON-THAN- GAS-POWERED-CAR#COMMENTS) VIEW DISCUSSION The U.S. government has pumped $5.5 billion in federal grants and loans into manufacturing and promoting electric cars and batteries. But research by Bjorn Lomborg of the Copenhagen Consensus Center (http://www.copenhagenconsensus.com/CCC% 20Home%20Page.aspx)finds that a typical electric car driven 50,000 miles over its lifetime emits more carbon-dioxide than a similar-size gas-powered car driven the same distance. The reason: manufacturing electric cars, which involves mining for lithium, produces over twice the amount of carbon-dioxide emissions (30,000 pounds for an electric car versus 14,000 for a conventional vehicle) as gas-powered cars. Lomborg says electric cars would have to be driven “a lot” to “get ahead environmentally,” and that is only if the driver somehow avoids coal-powered electricity. Even then, says (http://online.wsj.com/article/SB10001424127887324128504578346913994914472.html) Lomborg, the gains would be minimal. Even if the electric car is driven for 90,000 miles and the owner stays away from coal- powered electricity, the car will cause just 24% less carbon-dioxide emission than its gas-powered cousin….Over its entire lifetime, the electric car will be responsible for 8.7 tons of carbon dioxide less than the average conventional car. Those 8.7 tons may sound like a considerable amount, but it's not…An optimistic assessment of the avoided carbon-dioxide associated with an electric car will allow the owner to spare the world about $44 in climate damage. Last month, the “father of the Prius,” Takeshi Uchiyamada declared that electric cars were simply “not viable.” "Because of its shortcomings--driving range, cost and recharging time- -the electric vehicle is not a viable replacement for most conventional cars," said (http://www.reuters.com/article/2013/02/04/us-autos-electric-hydrogen- idUSBRE91304Z20130204)Uchiyamada. "We need something entirely new." MOST POPULAR •Palin Slams DC 'A$$Clowns' for Throwing 'Pathetic' '#nerdprom' (http://www.breitbart.com/Big -Government/2013/04/27/Sarah-Palin -Slams-Obama-Permanent-Political- Class-For-Lavish-WHCD-Party) 2668 comments · 0 minutes ago •REPORT: Obama Spent Twice As Much Time On Vacation/Golf As On Economy (http://www.breitbart.com/Big- Government/2013/04/28/REPORT- Obama-Spent-Twice-As-Much-Time- On-Vacation-Golf-As-On-Economy) 1046 comments · 0 minutes ago •Pentagon Consults Anti-Christian Extremist to Develop Religious Tolerance Policy (http://www.breitbart.com/Big- Peace/2013/04/28/Pentagon-Consults -Extremist-Who-Calls-Christians- Monsters-and-Enemies-of-the- Constitution-to-Develop-Religious- Tolerance-Policy) 532 comments · 1 minute ago •Palin Hammers 'Radically Pro- Abortion' Obama for Planned Parenthood Speech (http://www.breitbart.com/Big- Government/2013/04/26/Palin- Hammers-Obama-For-Supporting- Planned-Parenthood) 2711 comments · 1 minute ago •Biden: Economy kept McCain from victory over Obama (http://www.breitbart.com/system/wire/DA5TMD5G0) 1510 comments · 39 minutes ago BREITBART VIDEO PICKS Holder comes under fire for treatment of … 25 SEND A TIP Page 1 of 3Electric Car Manufacturing's Massive Carbon Footprint 4/29/2013http://www.breitbart.com/Big-Government/2013/03/11/Average-Electric-Car-Produces-More-Carbon-Th... President Barack Obama previously promised to put one million electric cars on American roads by 2015, a statement Obama’s Energy Department has since quietly walked back. "Whether we meet that goal in 2015 or 2016, that's less important than that we're on the right path to get many millions of these vehicles on the road," said (http://www.reuters.com/article/2013/01/31/us-autos-greencars-chu- idUSBRE90U1B020130131)an Energy Department official. Last year, electric car sales totaled just 50,000 units. According to the Congressional Budget Office, federal policies to prop up and promote electric cars will cost (http://www.breitbart.com/Big-Government/2013/02/04/Father-of -the-Prius-Declares-Electric-Cars-Not-Viable)taxpayers $7.5 billion through 2019. Sponsored Links WEIRD Loophole in (New Mexico): If you pay more than $7 for car insurance you better read this now... www.ConsumerFinanceDaily.com New BlackBerry® Z10 Discover the BlackBerry Z10, built to keep you moving. Get it today. BlackBerry.com/BlackBerry-Z10 7% Annuity Return? Earn Guaranteed* Income for Life! Compare Rates Today. ExpertAnnuities.com Buy a link here 25 comments • Leave a message... Best Community #Share ⤤ •Reply • NixLeftyRats •2 months ago Don't even need to be a scientist to figure THAT out! There's more the enviro-friendly tree huger should know about these cars: The ineffeciency of MANUFACTURE and life cycle are only the beginning. All cars get scrapped one day! There is a problem to the environment that is not cheap regarding the batteries and many components! Government is just waiting for the chance to throw another tax on these cars for administration of their disposal! With such a small number of electric cars now it's not a problem--YET! If you really love the earth and green and hate warming, gas, diesel and oil is still the best and cleanest for transportation in the USA. I love conservation (of resources) so hope some day a new, better, clearer engine and energy comes along! But a sure sign the electric cars are a boodoggel is: Government subsidy! Government subsidy!Government subsidy! The new REAL better system to come along will be easily marketed on it's own! •Reply • Michael Long •14 days ago>NixLeftyRats You know, of course, that electric car auto batteries are recycled and reused? They're not just scrapped. •Reply • nowind •2 months ago Bad science makes for bad politics and vice versa. fmadsen •2 months ago 8★ Share › Share › Share › Fox News National Fingerprints, possible DNA collected in killing of 8-year-old California girl (http://feeds.foxnews.com/~r/foxnews/national/~3/STlBOecrpnc/) 29 Apr 2013, 7:03 AM PDT Pending US home sales reach 3-year high in March (http://feeds.foxnews.com/~r/foxnews/national/~3/4kSG3zTkiHQ/) 29 Apr 2013, 7:01 AM PDT Student shoots self in Ohio high school classroom, authorities say (http://feeds.foxnews.com/~r/foxnews/national/~3/yRmT2f5jpw8/) 29 Apr 2013, 6:48 AM PDT 40 ex-LAPD officers seek reviews of dismissals (http://feeds.foxnews.com/~r/foxnews/national/~3/KmcJ1Jg7zY0/) 29 Apr 2013, 6:46 AM PDT JC Penney to get $1.75B in financing, shares rise (http://feeds.foxnews.com/~r/foxnews/national/~3/yGNpmQfb1Nc/) 29 Apr 2013, 6:36 AM PDT SIGN UP FOR OUR NEWSLETTER SUBSCRIBE McCain, Graham: Syrian Chemical Weapons Threaten US (http://www.newsmax.com/Newswidget/US -Syria/2013/04/28/id/501703? promo_code=11550- 1&utm_source=11550Breitbart&utm_medium=nmwidget&utm_campaign=widgetphase1) Manchin: I'm Bringing Back Gun Control Bill (http://www.newsmax.com/Newswidget/US -Gun-Control- Manchin/2013/04/28/id/501700? promo_code=11550- 1&utm_source=11550Breitbart&utm_medium=nmwidget&utm_campaign=widgetphase1) Peter King: Russia Hid Information in Bombing Probe (http://www.newsmax.com/Newswidget/US -Boston-Marathon- Congressman/2013/04/29/id/501755? promo_code=11550- 1&utm_source=11550Breitbart&utm_medium=nmwidget&utm_campaign=widgetphase1) Should Obama's Health Plan Be Overturned? Vote Here Now (http://www.newsmax.com/surveys/Obama -Policies/Should-Congress-Repeal-- Obama-s-Health-Plan-and- Ot/id/13/kw/default?promo_code=11550- 1&utm_source=11550Breitbart&utm_medium=nmwidget&utm_campaign=widgetphase1) Obama ‘Blunder’ Spawns Massive Profit Opportunity (http://w3.newsmax.com/newsletters/uwr/vi Page 2 of 3Electric Car Manufacturing's Massive Carbon Footprint 4/29/2013http://www.breitbart.com/Big-Government/2013/03/11/Average-Electric-Car-Produces-More-Carbon-Th... Appendix D. Safety and Permitting -MORE- Lorraine Carli National Fire Protection Association (617) 984-7275 publicaffairs@nfpa.org Jeff R. Ennenga Alaska Division of Fire & Life Safety (907) 269-5789 jeff.ennendga@alaska.gov NFPA and the Alaska Division of Fire and Life Safety Host Electric Vehicle Safety Training for First Responders October 25, 2012 — First responders from Anchorage and the surrounding area will have the opportunity to learn more about essential guidelines for responding to emergency situations involving electric and hybrid vehicles. The Alaska Division of Fire and Life Safety and the National Fire Protection Association (NFPA) will host an in-classroom, train-the-trainer session on October 27th. The course, which is part of NFPA’s nationwide Electric Vehicle Safety Training Project, will provide local firefighters with information to help them respond safely and effectively to electric and hybrid vehicles emergencies on the road. Participants will be able to use the new information and resources to prepare other firefighters and first responders throughout the state. Alaska is the 40th state to host NFPA’s train-the-trainer course, which began touring state fire training institutions in the summer of 2011 and was recently modified to serve the law enforcement community as well. “NFPA’s program provides first responders with all the necessary information for safely handling emergency situations involving electric and hybrid vehicles,” said Jeff R. Ennenga, Director of Training for the Alaska Division of Fire and Life Safety. “Participants in NFPA’s course will receive first-hand experience working with the new technologies and risks posed by these vehicles. Most importantly, they can use the comprehensive training they receive to keep our community safe and to teach other first responders.” For more than 100 years NFPA has been a leading voice for public safety. NFPA’s course is based on extensive research and findings from the Fire Protection Research Foundation. Since the Electric Vehicle Training Project was first announced, NFPA has worked with safety experts and auto manufacturers to provide a comprehensive curriculum of up-to-date information on the topic. According to NFPA President James M. Shannon, standardized electric vehicle education based on best practices is critical to emergency training for first responders across the country. “NFPA, along with state fire academies across the country, is supporting the large-scale introduction of electric and hybrid vehicles by helping ensure that firefighters and first responders are familiar with any new car coming down the road,” Shannon said. “Our goal is to provide first responders with all the information and materials necessary to respond to emergency situations involving these vehicles.” Page 2 of 2 # # # The training also will feature a live training demonstration involving a Toyota Prius and Camry hybrid, provided by Kendall Toyota of Anchorage, and a Lexus RX 450 provided by Kendall Lexus of Alaska. Participants will be able to experience first-hand the new technologies and special features included in these vehicles. During the 8-hour course, NFPA instructor Matt Paiss will cover a variety of topics specific to both hybrid and electric vehicles, including the extrication process, risk of electric shock, handling new types of batteries and challenges presented by charging stations. In addition to the classroom experience and hands-on training, each participant will receive an instructor’s guide and quick reference manual regarding electric vehicles, as well as a multimedia disc containing all of the course content. Participants also receive a Certificate of Completion at the conclusion of the course. This summer, NFPA released an online version of the electric vehicle safety course. The online, self- paced program – available on mobile devices and computers – covers the same content as the classroom training, providing first responders with the tools and information they need to safely handle emergency situations involving electric vehicles, plug-in electric vehicles and charging stations. For more information about the electric vehicle training series, the online training and to register for upcoming sessions, visit: www.evsafetytraining.org/Training. About the Alaska Division of Fire and Life Safety The Alaska Division of Fire and Life Safety is a division of the Alaska Department of Public Safety. The Division is committed to protecting all Alaskans from fire and explosion. The Director of the Alaska Division of Fire and Life Safety is State Fire Marshal Kelly Nicolello and is divided into three bureaus: Life Safety Inspection Bureau, Plans Review Bureau and the Training and Education Bureau. About NFPA’s Electric Vehicle Safety Training Project NFPA’s Electric Vehicle Safety Training Project is a nationwide program designed to help firefighters and other first responders prepare for the growing number of electric vehicles on the road in the United States. The NFPA project, funded by a $4.4 million grant from the U.S. Department of Energy, provides first responders with information they need to most effectively deal with potential emergency situations involving electric vehicles. About the National Fire Protection Association (NFPA) NFPA is a worldwide leader in fire, electrical, building and life safety. The mission of the international nonprofit organization founded in 1896 is to reduce the worldwide burden of fire and other hazards on the quality of life by providing and advocating consensus codes and standards, research, training and education. Visit NFPA’s website at www.nfpa.org for more information. Subscribe to NFPA RSS News feeds Lorraine Carli NFPA Public Affairs (617) 984-7275 publicaffairs@nfpa.org Preparing a home for electric vehicle charging and metering requires the collaboration of several parties to help customers make the right decisions for their individual situations. Southern California Edison (SCE), electricians, customers, and cities each play important roles in this process. This guide provides useful information on the process for preparing electric vehicle customers’ single family residences for safe and reliable electric vehicle charging. The process may include installing an electric vehicle charging station, second electrical panel, meter socket box, and/or two-socket panel to accommodate separate electric vehicle metering. Installing this equipment is optional and depends on the SCE rate plan the customer enrolls in and the level at which the customer chooses to charge the vehicle (120 volts or 240 volts). Each customer should select their rate plan and charging level before the electrician begins any electrical work on the house. Otherwise, customers and electricians alike run the risk of costly delays. Before you assess your customers’ home panel and wiring needs, please ensure that customers who live in SCE’s service territory contact SCE to learn about their rate plan options and how each rate plan may affect their home panel, wiring, and electric vehicle charging options. Electrician Guide for Installing Electric Vehicle* Charging Stations at Single-Family Homes FOR OVER 100 YEARS...LIFE. POWERED BY EDISON. Electrician Guide for Installing Electric Vehicle Charging Stations at Single-Family Homes Last Updated: 12/3/2010 1 * Light duty passenger electric vehicles Charging Station Direct customers to call: 1-800-4EV-INFO (800-438-4636) (Press “0” to be transferred to a customer service specialist) Or visit: www.sce.com/PEV Installation Process The flowchart below illustrates the basic processes used by SCE to get customers in single-family homes “plug-in ready.” Also shown are the points at which electricians play an especially important role in moving the installation process forward. * By reminding your customers to call both you and SCE after deciding on the electrical work, SCE can send a Service Planner to your customer’s home so you can finish your work as quickly as possible. Knowing each customer’s rate plan selection, electrical vehicle charging level, and planned panel configuration will allow SCE’s Service Planners to properly inspect the local transformer and service drops and evaluate the customer’s electrical plan. Automaker/Dealer Advises Electric Vehicle Customer On… • Charging preparation • Calling SCE about rate plan options SCE… • Dispatches Service Planner to verify adequacy of SCE infrastructure and evaluate customer’s electrical plan, as needed • Communicates results to customer SCE Provides Customer… • Analysis of rate plan options • Description of each rate plan’s impact on home electrical panel and wiring needs Electrician… • Confirms customer has contacted SCE • Assesses customer’s home wiring and panel needs, with customer’s rate plan preference in mind • Provides price quote to complete work for all applicable rate/ panel options Electrician… • Obtains city permit(s) • Completes installation of necessary home wiring, upgraded or new panel, and/ or electric vehicle charging equipment • Arranges for city inspection Customer… • Considers rate plan and charging options • Selects rate plan and panel wiring approach • Informs SCE and electrician All systems “go” for electric vehicle charging! SCE… • Receives city inspection approval • Completes meter work (as needed) • Updates customer billing rate plan (as needed) “Dear Customer, please let me and SCE know when you’ve decided on the electrical work you’d like done.”* Electrician Guide for Installing Electric Vehicle Charging Stations at Single-Family Homes Last Updated: 12/3/2010 2 Rate/Panel Options The combination of SCE electric vehicle rate plans and panel configurations yields 6 Rate/Panel options: Important Steps for Electrician 1. Confirm customer has contacted SCE about rate plan options and implications before conducting home assessment of electrical panel and wiring needs. If not, direct the customer to call 1-800-4EV-INFO (1-800-438-4636) M-F, 8:00 am - 5:00 pm. 2. Evaluate residential electrical panel and wiring for capacity to charge the electric vehicle. 3. Provide price quote to complete electrical work for all applicable rate/panel options. 4. Once SCE has approved the proposed electrical plan, upgrade the existing panel or add a second panel or meter socket box, as necessary, with customer’s rate plan choice in mind. 5. For Electric Vehicle Plan: install the appropriate panel option and remember that this power is for electric vehicle charging only. Note: SCE will install the second meter after the panel is installed and the city approves the installation. 6. Refer to SCE’s Electric Service Requirements (ESR) for complete panel configuration details (www.SCE.com/AboutSCE/Regulatory/DistributionManuals/ESR.htm ). * With tiered rates, cost per kWh increases with the amount of electricity used. Rate Rate Plans Description Panel Choices Residential Plan (D) Single Meter Home & Electric Vehicle Plan (TOU-D-TEV) Single Meter Electric Vehicle Plan (TOU-EV-1) Two Meters Tiered Rate* Home and electric vehicle loads measured together Time of Use Tiered Rate* Home and electric vehicle loads measured together; rates higher during the day and lower at night Time of Use Rate Electric vehicle load metered separately from home load; home remains on current rate and meter; electric vehicle rate is higher during the day and lower at night Use Existing Panel Option #1 (likely no meter change) Option #3 (meter may need to be replaced) N/A Add 2nd Panel or Meter Socket Box N/A N/A Option #5 Upgrade Existing Panel Option #2 (likely no meter change) Option #4 (meter may need to be replaced) Option #6 (panel upgrade or addition must take place before second meter is installed) See page 4 for detailed panel configurations. Electrician Guide for Installing Electric Vehicle Charging Stations at Single-Family Homes Last Updated: 12/3/2010 3 Note: SCE provides only a single service line for all panel configurations, regardless of whether one or two panels are installed. For additional information about panel configurations, please refer to SCE’s Electric Service Requirements (ESR) available at www.sce.com/AboutSCE/Regulatory/DistributionManuals/ESR.htm Panel Configurations Rate/Panel Options 5 and 6 require two meters and either a separate panel, meter socket box, or a two-socket panel to accommodate both meters. Several panel configurations are shown below: Electrician Guide for Installing Electric Vehicle Charging Stations at Single-Family Homes Last Updated: 12/3/2010 4 Note: Where at all possible, the second panel or meter socket box shall be at the same location and directly adjacent to the existing metering. Overhead Service Rate / Panel Option #6Underground Service Rate / Panel Option #5Existing Home Panel New Upgraded Home Panel New Upgraded Home Panel Existing Home Panel Circuit Protection Circuit Protection Existing Home Meter Existing Home Meter Existing Home Meter New IDR Meter or New SmartConnect™ Meter New IDR Meter or New SmartConnect™ Meter UG Service Entrance UG Service Entrance OH Service Entrance OH Service Entrance Existing Home Meter EMT or Flex Conduit Pull Box Refer to ESR-3, for Pull Box Requirements Second Panel or Meter Socket Box with New IDR Meter or New SmartConnect™ Meter Second Panel or Meter Socket Box with New IDR Meter or New SmartConnect™ MeterNew Riser and Weatherhead To EVSE To EVSE To EVSE To EVSE M M M M M M M M Key UG: Underground OH: Overhead IDR: Interval Data Read EMT: Electrical Metallic Tubing EVSE: Electric Vehicle Service Equipment Compliance with the following permit will allow the installation and operation of electric vehicle charging equipment at a residence in the City, State jurisdiction. This permit addresses one of the following situations: Only an additional branch circuit would be added at the residence A hard-wired charging station would be installed at the residence. The attached requirements for wiring the charging station are taken directly out of the 2011 edition of the National Electrical Code (NEC) NFPA 70, Article 625 Electric Vehicle Charging System. This article does not provide all of the information necessary for the installation of electric vehicle charging equipment. Please refer to the current edition of the electrical code adopted by the local jurisdiction for additional installation requirements. Reference to the 2011 NEC may be made at www.nfpa.org/70. This permit contains a general reference to the NEC or electrical code used in the jurisdiction. All work and installed equipment will comply with the requirements of the NEC or the electrical code used in the jurisdiction. The jurisdiction maintains the authority/responsibility to conduct any inspections deemed necessary to protect public safety. The charging station installer shall also be responsible for notifying or coordinating any work with the utility company where needed. Section 1 of the permit application requires basic identifying information be submitted. Note that there is a separate portion of the form requesting information on the property owner who may not be the individual requesting the installation. Section 2 of the permit application identifies which code needs to be complied with depending on whether a branch circuit and meter or a hard-wired charging station is being installed. The technical installation requirements address the following specific elements of electric vehicle charging station safety: Listing and labeling requirements Wiring methods Breakaway requirements Overcurrent protection Indoor siting Outdoor siting Section 3 consists of standard certification statement that could be modified as needed by the jurisdiction. By signing the certification statement, the applicant agrees to comply with the standard permit conditions and other applicable requirements. This consent would give the jurisdiction the option of allowing the applicant to proceed with installation and operation of the charging equipment. Section 4 of the document gives an example of a checklist the jurisdiction could develop to track key information on the application. The example under section 4 contains only a few items of the many that the jurisdiction might wish to track. This permit package also includes a schematic drawing depicting a typical indoor installation. In this installation the wiring path follows the exterior of the structure, and the charging station is located indoors. The NEC allows for interior wiring and outdoor installations. The purpose of the schematic is only to show how the charging station equipment could be arranged and is not intended to convey any permit requirements. Application for Installation of Electric Vehicle Charging Equipment Section 1: Permit Applicant Information Section 2: Permit Code Information Requirements for wiring the charging station are taken directly out of the 2011 edition of the National Electrical Code® (NEC) ® NFPA 70, Article 625 Electric Vehicle Charging System. This article does not provide all of the information necessary for the installation of an electric vehicle charging equipment. Please refer to the current edition of the electrical code adopted by the local jurisdiction for additional installation requirements. Reference to the 2011 NEC may be made at www.nfpa.org/70. NEC Chapter or Article DESCRIPTION Chapter2 and 3 Branch Circuit A new electrical box added on a branch circuit shall comply with NFPA 70 National Electrical Code® Chapter 2 Wiring and Protection and Chapter 3 Wiring Methods and Materials and all administrative requirements of the NEC or the electrical code in effect in the jurisdiction 625.4 VOLTAGES Unless other Voltages are specified, the nominal ac system voltages of 120, 120/240, 208Y/120, 240, 480Y/277, 480, 600Y/347, and 600 Volts shall be used to supply equipment 625.5 LISTED OR LABELED All electrical materials, devices, fittings, and associated equipment shall be listed or labeled. Name: Installation Street Address (P.O. box not acceptable): Contact Person: Phone Number: ( ) - City: County: State: ZIP Code: Owner Name: Street Address: Phone Number: ( ) - City: State: ZIP Code: Submitter's Name/Company Street Address: Phone Number: ( ) - City: State: ZIP Code: General description of equipment to be installed: NOTICE: The system must be installed in compliance with NFPA 70, National Electric Code, Article 625 or applicable Electrical Code currently adopted and enforced within the jurisdiction of installation. All associated work with circuits, electrical service and meters shall be completed in compliance with NFPA 70, national electric code, or applicable electrical code currently adopted and enforced within the jurisdiction of installation. 625.9 WIRING METHODS The electric vehicle coupler shall comply with 625.9(A) through (F). (A) Polarization. The electric vehicle coupler shall be polarized unless part of a system identified and listed as suitable f or the purpose. (B) Noninterchangeability. The electric vehicle coupler shall have a configuration that is noninterchangeable with wiring devices in other electrical systems. Nongrounding-type electric vehicle couplers shall not be interchangeable with grounding-type electric vehicle couplers. (C) Construction and Installation. The electric vehicle coupler shall be constructed and installed so as to guard against inadvertent contact by persons with parts made live from the electric vehicle supply equipment or the electric vehicle battery. (D) Unintentional Disconnection. The electric vehicle coupler shall be provided with a positive means to prevent unintentional disconnection. (E) Grounding Pole. The electric vehicle coupler shall be provided with a grounding pole, unless part of a system identified and listed as suitable for the purpose in accordance with Article 250. (F) Grounding Pole Requirements. If a grounding pole is provided, the electric vehicle coupler shall be so designed that the grounding pole connection is the first to make and the last to break contact. 625.13 ELECTRIC VEHICLE SUPPLY EQUIPMENT Electric vehicle supply equipment rated at 125 volts, single phase, 15 or 20 amperes or part of a system identified and liste d as suitable for the purpose and meeting the requirements of 625.18, 625.19, and 625.29 shall be permitted to be cord-and- plug-connected. All other electric vehicle supply equipment shall be permanently connected and fastened in place. This equipment shall have no exposed live parts. 625.14 Rating Electric vehicle supply equipment shall have sufficient rating to supply the load served. For the purposes of this article, electric vehicle charging loads shall be considered to be continuous loads. 625.15 Markings The electric vehicle supply equipment shall comply with 625.15(A) through (C). (A) General. All electric vehicle supply equipment shall be marked by the manufacturer as follows: FOR USE WITH ELECTRIC VEHICLES (B) Ventilation Not Required. Where marking is required by 625.29(C), the electric vehicle supply equipment shall be clearly marked by the manufacturer as follows: VENTILATION NOT REQUIRED The marking shall be located so as to be clearly visible after installation. (C) Ventilation Required. Where marking is required by 625.29(D), the electric vehicle supply equipment shall be clearly marked by the manufacturer, “Ventilation Required.” The marking shall be located so as to be clearly visible after installation. 625.16 Means of Coupling The means of coupling to the electric vehicle shall be either conductive or inductive. Attachment plugs, elec tric vehicle connectors, and electric vehicle inlets shall be listed or labeled for the purpose. 625.17 Cable The electric vehicle supply equipment cable shall be Type EV, EVJ, EVE, EVJE, EVT, or EVJT flexible cable as specified in Article 400 and Table 400.4. Ampacities shall be as specified in Table 400.5(A)(1) for 10 AWG and smaller, and in Table 400.5(A)(2) for 8 AWG and larger. The overall length of the cable shall not exceed 7.5 m (25 ft) unless equipped with a cable management system that is listed as suitable for the purpose. Other cable types and assemblies listed as being suitable for the purpose, including optional hybrid communications, signal, and composite optical fiber cables, shall be permitted. 625.18 Interlock Electric vehicle supply equipment shall be provided with an interlock that de-energizes the electric vehicle connector and its cable whenever the electrical connector is uncoupled from the electric vehicle. An interlock shall not be required for portab le cord-and-plug-connected electric vehicle supply equipment intended for connection to receptacle outlets rated at 125 volts, single phase, 15 and 20 amperes. 625.19 Automatic De-Energization of Cable The electric vehicle supply equipment or the cable-connector combination of the equipment shall be provided with an automatic means to de-energize the cable conductors and electric vehicle connector upon exposure to strain that could result in either cable rupture or separation of the cable from the electric connector and exposure of live parts. Automatic means to de-energize the cable conductors and electric vehicle connector shall not be required for portable cord -and-plug-connected electric vehicle supply equipment intended for connection to receptacle outlets rated at 125 volts, single phase, 15 and 20 amperes. 625.21 Overcurrent Protection Overcurrent protection for feeders and branch circuits supplying electric vehicle supply equipment shall be sized for continuous duty and shall have a rating of not less than 125 percent of the maximum load of the electric vehicle supply equipment. Where noncontinuous loads are supplied from the same feeder or branch circuit, the overcurrent device shall have a rating of not less than the sum of the noncontinuous loads plus 125 percent of the continuo us loads. 625.22 Personnel Protection System The electric vehicle supply equipment shall have a listed system of protection against electric shock of personnel. The personnel protection system shall be composed of listed personnel protection devices and c onstructional features. Where cord-and-plug-connected electric vehicle supply equipment is used, the interrupting device of a listed personnel protection system shall be provided and shall be an integral part of the attachment plug or shall be located in t he power supply cable not more than 300 mm (12 in.) from the attachment plug. 625.23 Disconnecting Means For electric vehicle supply equipment rated more than 60 amperes or more than 150 volts to ground, the disconnecting means shall be provided and installed in a readily accessible location. The disconnecting means shall be capable of being locked in the open position. The provision for locking or adding a lock to the disconnecting means shall be installed on or at the swit ch or circuit breaker used as the disconnecting means and shall remain in place with or without the lock installed. Portable means for adding a lock to the switch or circuit breaker shall not be permitted. 625.25 Loss of Primary Source Means shall be provided such that, upon loss of voltage from the utility or other electrical system(s), energy cannot be back fed through the electric vehicle and the supply equipment to the premises wiring system unless permitted by 625.26. 625.26 Interactive Systems Electric vehicle supply equipment and other parts of a system, either on-board or off-board the vehicle, that are identified for and intended to be interconnected to a vehicle and also serve as an optional standby system or an electric power production source or provide for bi-directional power feed shall be listed as suitable for that purpose. When used as an optional standby system, the requirements of Article 702 shall apply, and when used as an electric power production source, the requirements of Article 705 shall apply. 625.28 Hazardous (Classified) Locations Where electric vehicle supply equipment or wiring is installed in a hazardous (classified) location, the requirements of Articles 500 through 516 shall apply. 625.29 Indoor Sites Indoor sites shall include, but not be limited to, integral, attached, and detached residential garages; enclosed and underground parking structures; repair and nonrepair commercial garages; and agricultural buildings. (A) Location. The electric vehicle supply equipment shall be located to permit direct con nection to the electric vehicle. (B) Height. Unless specifically listed for the purpose and location, the coupling means of the electric vehicle supply equipment shall be stored or located at a height of not less than 450 mm (18 in.) and not more than 1.2 m (4 ft) above the floor level. (C) Ventilation Not Required. Where electric vehicle nonvented storage batteries are used or where the electric vehicle supply equipment is listed or labeled as suitable for charging electric vehicles indoors without ventila tion and marked in accordance with 625.15(B), mechanical ventilation shall not be required. (D) Ventilation Required. Where the electric vehicle supply equipment is listed or labeled as suitable for charging electric vehicles that require ventilation for indoor charging, and is marked in accordance with 625.15(C), mechanical ventilation, such as a fan, shall be provided. The ventilation shall include both supply and exhaust equipment and shall be permanently installed and located to intake from, and vent directly to, the outdoors. Positive pressure ventilation systems shall be permitted only in buildings or areas that have been specifically designed and approved for that application. Mechanical ventilation requirements shall be determined by one of the metho ds specified in 625.29(D)(1) through (D)(4). (1) Table Values. For supply voltages and currents specified in Table 625.29(D)(1) or Table 625.29(D)(2), the minimum ventilation requirements shall be as specified in Table 625.29(D)(1) or Table 625.29(D)(2) fo r each of the total number of electric vehicles that can be charged at one time. (2) Other Values. For supply voltages and currents other than specified in Table 625.29(D)(1) or Table 625.29(D)(2), the minimum ventilation requirements shall be calculated by means of general formulas stated in article 625.39(D)(2). (3) Engineered Systems. For an electric vehicle supply equipment ventilation system designed by a person qualified to perform such calculations as an integral part of a building’s total ventilation system, the minimum ventilation requirements shall be permitted to be determined in accordance with calculations specified in the engineering study. (4) Supply Circuits. The supply circuit to the mechanical ventilation equipment shall be electrically int erlocked with the electric vehicle supply equipment and shall remain energized during the entire electric vehicle charging cycle. Electric vehicle supply equipment shall be marked in accordance with 625.15. Electric vehicle supply equipment receptacles rat ed at 125 volts, single phase, 15 and 20 amperes shall be marked in accordance with 625.15(C) and shall be switched, and the mechanical ventilation system shall be electrically interlocked through the switch supply power to the receptacle. 625.30 Outdoor Sites Outdoor sites shall include but not be limited to residential carports and driveways, curbside, open parking structures, parking lots, and commercial charging facilities. (A) Location. The electric vehicle supply equipment shall be located to permit direct connection to the electric vehicle. (B) Height. Unless specifically listed for the purpose and location, the coupling means of electric vehicle supply equipment shall be stored or located at a height of not less than 600 mm (24 in.) and not more tha n 1.2 m (4 ft) above the parking surface. Section 3: Certification Statement I hereby certify that the electrical work described on this permit application shall be/has been installed in compliance with the conditions in this permit, NFPA 70, National Electrical Code , Article 625, or applicable electrical code currently adopted and enforced within the jurisdiction of installation. Furthermore, all associated work with circuits, electrical service and meters shall be/has been completed in compliance with NFPA 70, National Electrical Code , or applicable electrical code currently adopted and enforced within the jurisdiction of installation. By agreeing to the above requirements, the licensee or owner shall be permitted to install and operate the charging station. The licensee also insures that appropriate load calculations have been done to insure that the residence has adequate electrical capacity to support electric vehicle charging equipment. Existing circuits provided for garages may supply other loads and may not have sufficient capacity for electric vehicle charging equipment. In some older installations the residential electrical service may not have sufficient capacity to supply electric vehicle charging equipment. Capacity problems are likely to be encountered on 60 ampere services or on 100 ampere services with multiple 240 volt loads. In such cases load calculations must be performed to insure adequate capacity. Section 4: Jurisdiction Checklist Information each jurisdiction would add to permit: Date utility notified of work completed Information on installation sent to tax assessor Indoor/outdoor location Modification to existing service required Other items as determined by the jurisdiction Signature of Licensee: Date: Signature of Owner: Date: Figure 1. Typical Electric Vehicle Charging Equipment Installations Home >Drive Electric!>A New Driving Experience BMW charging Charging Locator Chevrolet Volt Chevy Volt CODA Sedan Events Fit EV Fleets Ford Focus Electric Grid Electricity hands free Honda Incentives for EV Buyers Mitsubishi i mobile Nissan LEAF pluginday Prius Range RAV4 roadmap Safety Showroom Tesla Tesla Model S Tesla Roadster Toyota Transit Connect Electric Vehicles Connect RESOURCES resources First Responders Plug-in Readiness Plug-In EV Basics Electrician Guide Accessibility Video Gallery Plug-in Readiness For plug-in vehicles to be successful in the marketplace and achieve their true potential, it will take a concerted effort across a broad range of stakeholders to accomplish this transformational change in the way we move people and goods. Many communities have already formed plug-in vehicle readiness initiatives to help identify potential barriers to adoption and come up with solutions and incentives. For municipalities, this might involve a review of your permitting and inspection guidelines. The U.S. Department of Energy has created a template for a standard permit for residential charging stations that allows for quick, safe installation of EVSE. Businesses might work together to identify economic development opportunities and provide charging to entice customers, while employers might consider charging access for employees. Utilities will want to understand the potential impact to the grid. Given the many stakeholders involved, it’s important for all them to find a way to work together and collaborate in a plug-in readiness initiative. Various resources on plug-in readiness: • Clean Cities TV: Community Readiness Workshop • Rocky Mountain Institute Project Get Ready • Advanced Energy’s Community Planning Document •Template from DOE's Alternative Fuels & Advanced Vehicles Data Center to develop a standard permit for residential charging Regional Readiness Initiatives: •California (Plug-in Electric Vehicle Collaborative) •Michigan •Oregon •Virginia •Central Florida Utility Readiness Initiatives: •Edison Electric Institute Pledge back to top GET STARTED DRIVE ELECTRIC! ELECTRIC CARS CHARGING INCENTIVES FAQ & GLOSSARY NEWS & EVENTS ABOUT RESOURCES Search Page 1 of 2Plug-in Readiness 4/11/2013http://www.goelectricdrive.com/index.php/plug-in-readiness Technical Article Leviton Mfg. Co., Inc. Lighting Management Systems 20497 SW Teton Avenue, Portland, OR 97062 1-800-736-6682 Tech Line: 1-800-959-6004 Fax: 503-404-5594 www.leviton.com/lms © 2008 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice. PL-PD-F007 Rev. 1 06/23/2008 UL vs. ETL Listing Product: Leviton Wireless & Other Leviton Products Article ID: 012109-bf-01 Date: January 21, 2009 Summary: The purpose of this article is to clarify questions regarding the use and acceptance of ETL product certification versus UL certification on Leviton products. Information: There have been some questions recently in regards to the ETL certification of our new wireless products rather then using UL. The FAQ’s below should answer any question regarding this issue. One of the key reasons we chose to use ETL is the timeframe in which they can test and certify products is usually much faster then UL. ETL tests to the same standards as UL and their certification has the same recognition by OHSA since they are both Nationally Recognized Testing Laboratories. Frequently Asked Questions about the ETL Listed Mark Is the ETL Listed Mark legal equivalent to the UL and CSA Listed Marks? The true legal requirement to test and certify products for sale in the United States is a designation by the Occupational Safety and Health Administration (OSHA) as a Nationally Recognized Testing Laboratory (NRTL). An NRTL functions to provide independent evaluation, testing, and certification of any electrically operated or gas- and oil-fired product. ETL is recognized as an NRTL in the United States and, in a similar capacity, as a Testing Organization and Certifying Body in Canada by the Standards Council of Canada. A product bearing the ETL Listed Mark is determined to have met the minimum requirements of prescribed product safety standards. Moreover, the mark indicates that the manufacturer's production site conforms to a range of compliance measures and is subject to periodic follow-up inspections to verify continued conformance. What's the difference between the UL, CSA, and ETL Listed Marks? Both marks demonstrate that the product that bears it has met the minimum requirements of widely accepted product safety standards as determined through the independent testing of a Nationally Recognized Testing Laboratory (NRTL). And, as part of that testing regimen, the product manufacturer has agreed to periodic follow-up inspections to verify continued compliance. What is an NRTL? A Nationally Recognized Testing Laboratory (NRTL) is an independent laboratory recognized by the Occupational Safety and Health Administration (OSHA) to test products to the specifications of applicable product safety standards – such as those from Underwriters Laboratories (UL) and other standards-writing bodies. An NRTL's function is to provide an independent evaluation, testing, and certification of any electrically operated or gas- and oil-fired products. TECHNICAL ARTICLE Leviton Mfg. Co., Inc. Lighting Management Systems 20497 SW Teton Avenue, Tualatin, OR 97062 1-800-736-6682 Tech Line: 1-800-959-6004 Fax: 503-404-5594 www.leviton.com/lms © 2008 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice. PL-PD-F007 Rev. 1 06/23/2008 UL vs. ETL Listing (cont’d) What are the specifics of the NRTL program? The NRTL program is part of OSHA's Directorate of Technical Support. As part of OSHA's directive to ensure that products are safe for use in the U.S. workplace, the NRTL program recognizes the capabilities of private sector organizations to determine if specific products meet consensus safety standards. OSHA safety standards are United States law and can be found in Title 29 of the Code of Federal Regulations (CFR). More specifically , the provisions for NRTL certification can be found within Part 1910 of the CFR (29 CFR Part 1910). It is important to note that OSHA's recognition of an NRTL is not a grant of government authority, but rather an acknowledgment of the organization's ability to perform product safety testing and certification within the scope of its OSHA recognition. Aren't manufacturers required to use UL for their compliance testing? Isn't this mandated by the standards themselves? The simple answer to both questions is "no." In fact, this misconception has misled many manufacturers to believe that they don't have a choice in their third-party testing partner. To satisfy the prerequisite of having your products tested by an independent organization, the true legal requirement is that the laboratory which performs the testing be a Nationally Recognized Testing Laboratory (NRTL) recognized by OSHA. What does the ETL Listed Mark mean when displayed on my product? In short, the ETL Listed Mark indicates that your product has been tested by a NRTL, found in compliance with accepted national standards, and meets the minimal requirements required for sale or distribution. To your distributors, retailers, and customers, the ETL Mark is assurance that the product is compliant with safety standards, having been tested and certified by a third-party organization. Will retailers accept my product if it bears the ETL Listed Mark? Yes. Since the ETL Listed Mark is an accepted and recognized demonstration of product compliance, and testing is performed by an NRTL, there is no reason why retailers should not accept products bearing the ETL Listed Mark. Any indication otherwise by an individual retailer or distributor likely stems from misinformation in the marketplace—the same misinformation that has led some manufacturers to believe they don't have a choice in their third-party testing organization. What should I tell my clients who aren't familiar with the ETL Listed Mark? There is no standard formula for better acquainting clients and customers with the ETL Listed Mark. Depending on the background, circumstances, and other details of a given situation, the correct approach will be unique from one instance to another. Others may erroneously believe that the UL Mark is the only acceptable demonstration of product compliance and require a more thorough explanation of the true legal requirements behind third party product safety testing. It is important to listen closely to your client's issues and provide them with real answers to their concerns. Inform them about the NRTL program. Explain to them how our Product Safety Certification Program includes the same testing, listing, labeling, and follow-up inspection services as UL, and that we're accredited by the same organizations, agencies, and regulatory bodies. TECHNICAL ARTICLE Leviton Mfg. Co., Inc. Lighting Management Systems 20497 SW Teton Avenue, Tualatin, OR 97062 1-800-736-6682 Tech Line: 1-800-959-6004 Fax: 503-404-5594 www.leviton.com/lms © 2008 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice. PL-PD-F007 Rev. 1 06/23/2008 UL vs. ETL Listing (cont’d) What countries accept the ETL Mark? The ETL Mark is an accepted demonstration of product compliance in both the United States and Canada. Do local inspectors know the ETL Listed Mark? Yes. The ETL Listed Mark is recognized by local inspectors and Authorities Having Jurisdiction (AHJs) throughout North America and also in some areas of South America. A an NRTL recognized by OSHA, the ETL Listed Mark is an accepted alternative to UL and, as such, inspectors and AHJs recognize, acknowledge, and accept the mark as proof of product compliance. Is ETL Listed Mark is accepted throughout North America? Amway Corp, JCPenney, Sam’s Club, Sears, and the list goes on. Since the ETL Listed Mark is a recognized and accepted indicator of a product’s compliance to safety standards, retailers, inspectors, or Authorities Having Jurisdiction (AHJs) all accept ETL Listed Products. How long has the ETL Listed Mark Been Around? “ETL” has been around over 100 years. In fact, the original Electrical Testing Labs (ETL) was founded by Thomas Edison in 1896. Electrical Testing Labs was formed to address concerns of lamp safety and performance issues. Edison’s vision was to provide assurance to consumers, through various types of product performance and safety tests. The basic principles of Edison’s third-party lamp testing methods remain the same today. Experts monitored lamps and bulbs to determine how long they would burn, the luminous intensity, and if everything burned as it should – without combustibility or explosion. What are the variations of the ETL Listed Mark? A product bearing the ETL Listed mark with the "us" identifier at the 4 o'clock position has been tested and deemed compliant to U.S. product safety standards only. An ETL Listed mark with a "c" identifier at the 8 o'clock position means the product bearing it complies with Canadian product safety standards only. And an ETL Listed mark with both "us" and "c" identifiers at the 4 o'clock and 8 o'clock positions respectively, signifies that the product bearing the mark complies with both U.S. and Canadian product safety standards. Contact: If you have any questions or concerns, please call LMS technical support at (800) 959-6004. Appendix E. Fleet Charging Plug-In Electric Vehicle Handbook for Public Charging Station Hosts Plug-In Electric Vehicle Handbook for Public Charging Station Hosts2 Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . .3 PEV Basics . . . . . . . . . . . . . . . . . . . . . . . . .4 Charging Basics . . . . . . . . . . . . . . . . . . . . .6 Benefits and Costs of Hosting a Charging Station . . . . . . . . . . .9 Charging Station Locations and Hosts . . . . . . . . . . . . . . . . .12 Ownership and Payment Models . . . . . .14 Installing and Maintaining Charging Stations . . . . . . . . . . . . . . . . . . . 15 Electrifying the Future . . . . . . . . . . . . . .19 Clean Cities Helps Establish PEV Charging Stations Establishing plug-in electric vehicle (PEV) charging stations requires unique knowledge and skills . If you need help, contact your local Clean Cities coordinator . Clean Cities is the U .S . Department of Energy’s flagship alterna- tive-transportation deployment initiative . It is supported by a diverse and capable team of stakeholders from private companies, utilities, government agencies, vehicle manufacturers, national laboratories, and other transporta- tion-related organizations . These stakehold- ers, organized into nearly 100 Clean Cities coalitions nationwide, are ready to help with specific charging station challenges . Contact your local coordinator by visiting the Clean Cities website at www.cleancities.energy.gov . Acknowledgement Thanks to the Electric Vehicle Infrastructure Training Program for assisting with the production of this handbook . See www.eere.energy.gov/cleancities/evitp.html . Photo from George Beard, Portland State University, NREL/PIX 18564 Disclaimer This report was prepared as an account of work sponsored by an agency of the United States government . Neither the United States government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the ac- curacy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights . Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States government or any agency thereof . The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States government or any agency thereof . Plug-In Electric Vehicle Handbook for Public Charging Station Hosts 3 You’ve heard about the new generation of plug-in electric vehicles (PEVs) like the Chevy Volt and Nissan Leaf. You manage a location that could host a PEV charging station — such as a retail business, office or municipal building, utility, or parking garage — and you’re wondering how you can be part of the electric transportation revo- lution. This handbook is for you. If you have a property suitable for hosting an electric charging station, you are perfectly positioned to contribute to — and benefit from — the fast-growing PEV sector. This handbook answers your basic ques- tions about PEVs and charging infrastructure and points you to the additional information you need to decide about participating in this new venture. More than 100 years ago, all-electric vehicles (EVs) held much of the U.S. car market, but their popularity waned as the interest in conventional cars with inter- nal combustion engines (ICEs) rose. The ICE vehicle had a longer driving range, petroleum fuel costs were declining, and the introduction of the electric starter and manufacturing assembly line improved the usabil- ity and affordability of ICE vehicles. Gasoline- and diesel-powered ICE vehicles ended up dominating transportation in the 20th century. However, concerns about the environmental impacts of conventional ICE vehicles sparked a PEV renais- sance at the end of the 20th century. In 1990, Cali- fornia passed the nation’s first zero emission vehicle mandate, putting the state at the forefront of that decade’s deployment of PEVs such as the General Motors EV1, Chrysler EPIC, Ford Ranger EV, and Toyota RAV4 EV. Many vehicles from this genera- tion were discontinued in the early 2000s, and the number of non-residential charging stations — which had peaked at nearly 900 in 2002 — dwindled to about 400 by 2008. However, California’s vision helped set the stage for the next generation of PEVs and charging stations. Today, PEVs are back and ready to compete with — and complement — the ubiquitous ICE tech- nology. First, advances in electric-drive technologies enabled commercialization of hybrid electric vehi- cles (HEVs), which integrate an ICE or other power source with batteries, regenerative braking, and an electric motor to boost fuel economy. Continued technological advances have spawned plug-in HEVs Key Acronyms EVs (all-electric vehicles) are powered only by one or more electric motors . They receive electricity by plugging into the grid and store it in batteries . They consume no petroleum-based fuel while driving and produce no tailpipe emissions . EVSE (electric vehicle supply equipment) deliv- ers electrical energy from an electricity source to charge a PEV’s batteries . It communicates with the PEV to ensure that an appropriate and safe flow of electricity is supplied . EVSE units are commonly referred to as “charging stations .” HEVs (hybrid electric vehicles) combine an ICE or other propulsion source with batteries, regenerative braking, and an electric motor to provide high fuel economy . They rely on a petroleum-based or an alternative fuel for power and are not plugged in to charge . HEV batteries are charged by the ICE or other propulsion source and during regen- erative braking . ICEs (internal combustion engines) generate mechanical power by burning a liquid fuel (such as gasoline, diesel, or biofuels) or a gaseous fuel (such as compressed natural gas) . They are the dominant power source for on-road vehicles today . PEVs (plug-in electric vehicles) derive all or part of their power from electricity supplied by the electric grid . They include EVs and PHEVs . PHEVs (plug-in hybrid electric vehicles) use batteries to power an electric motor, plug into the electric grid to charge, and use a petroleum-based or an alterna- tive fuel to power an ICE or other propulsion source . Introduction Photo from Electric Vehicle Infrastructure Training Program Plug-In Electric Vehicle Handbook for Public Charging Station Hosts4 President Obama set a goal of having 1 million PEVs on the road by 2015. Many of these vehicles will charge primarily at drivers’ homes, but a large and widely dis- tributed network of public and workplace charging sta- tions is essential for providing the convenience, range, and confidence required by the majority of drivers. The proliferation of non-residential charging units has accel- erated already — surpassing 7,000 in 2012 — with the help of government-supported deployment projects. As a potential station owner or host, you have the opportu- nity to benefit from this trend while helping drive PEV deployment in the United States. Before learning about charging stations, it’s useful to learn a little about the vehicles and drivers that will use them. What makes a PEV a PEV is the ability to charge from an off-board electric power source — PEVs can be “plugged in.” This feature distinguishes them from HEVs, which supplement power from an ICE or other propulsion source with battery power but cannot be plugged in. There are two basic types of PEVs: EVs and PHEVs. All-Electric Vehicles (EVs) EVs (also called battery-electric vehicles, or BEVs) use batteries to store the electrical energy that powers one or more motors. The batter- ies are charged by plugging the vehicle into an electric power source. In addition, EVs can be charged in part by regenerative braking, which generates electricity from some of the energy normally lost when braking. It’s as simple as that — EVs have no ICEs and produce no tail- pipe emissions. Today’s EVs typically have a shorter range than conven- tional vehicles have. Most light-, medium-, and heavy- duty EVs are targeting a range of about 100 miles on a fully charged battery. The range depends in part on driving conditions and habits. The time required to charge depleted batteries — wh ich can range from less than 30 minutes to almost a full day — depends on the size and type of the batteries, as well as the type of charging equipment used. Learn more about charging in the Charging Basics section. Neighborhood electric vehicles (NEVs), also called low- speed vehicles, are a type of EV with range and speed limitations. NEVs are commonly used for neighbor- hood commuting, light hauling, and delivery. They are often limited to use on roads with speed limits up to 35 miles per hour, making them ideal for college cam- puses and similar applications. There are also specialty EVs, such as airport ground support equipment and personal transporters, which are not intended for road use. Although these types of vehicles are valuable for the niches they serve, this handbook focuses on EVs designed for highway use. PEV Basics Under the hood of a Nissan Leaf . An EV contains no ICE; instead, the battery supplies electricity to the electric motor . Photo from Margaret Smith, DOE, NREL/PIX 18215 (PHEVs), which integrate small ICEs (or other power sources) and large, grid-chargeable batteries that enable all-electric driving ranges of 10 to 40 miles or more. Advanced technologies have also enabled manufactur- ers to introduce a new generation of EVs that don’t use an ICE at all. At the same time, charging station tech- nologies have evolved to facilitate a range of charging options and business models. Only a few models of new-generation PEVs are available today. However, because of the benefits they offer, PEV market penetration and availability are growing quickly. Plug-In Electric Vehicle Handbook for Public Charging Station Hosts 5 Plug-In Hybrid Electric Vehicles (PHEVs) PHEVs (sometimes called extended range electric vehicles, or EREVs) use batteries to power an electric motor and use another fuel, such as gasoline or diesel, to power an ICE or other propulsion source. Powering the vehicle some of the time with electricity from the grid cuts petroleum consumption and tailpipe emissions, compared with conventional vehicles. When running on gasoline, PHEVs, like HEVs, consume less fuel and typi- cally produce lower emissions than similar ICE vehicles. PHEVs have larger battery packs than HEVs, providing an all-electric driving range of about 10 to 40-plus miles for current light-duty models. During typical urban driving, most of a PHEV’s power can be drawn from stored electricity. For some urban fleet applications, a PHEV could be driven on all-electric power all day and then charged at night or even during a down time like lunch. The ICE powers the vehicle when the battery is mostly depleted, during rapid acceleration, or when intensive heating or air conditioning is required. Some heavy-duty PHEVs work the opposite way, with the ICE used for driving to and from a job site and electricity used to power the vehicle’s equipment or control the cab’s climate while at the job site. Because the vehicle would otherwise be idling at the job site for powering equipment or climate control, this PHEV strategy can result in significant fuel savings. Like EVs, PHEVs can be plugged into the grid and charged, although the time required to charge depleted batteries is typically shorter for PHEVs, because most have smaller battery packs. In addition, battery charge is augmented by a PHEV’s ICE and regenerative braking. PHEV fuel consumption depends on the distance driven between battery charges. For example, if the vehicle is never plugged in to charge, fuel economy will be about the same as for a similarly sized HEV. If the vehicle is driven less than its all-electric range and plugged in to charge, it may be possible to use only electric power. Why Drivers Choose PEVs The reasons drivers choose PEVs range from a desire to improve the world to a desire to save money . The following list of PEV benefits illus- trates why the demand for PEVs — and thus for charging stations — has been growing rapidly . High Fuel Economy, Low Operating Cost: PEVs are highly efficient, and they have much lower operating costs compared with conventional gasoline and diesel vehicles . Flexible Fueling: Compared with conventional vehicles, PEVs offer additional fueling options, including charging at home, work, commercial charging stations, other public locations, private fleet facilities, or a combination of these sites . High Performance: Today’s PEVs are state-of-the- art highway vehicles ready to match or surpass the performance of their conventional gasoline and diesel counterparts . Low Emissions: Compared with conventional vehicles, PEVs typically produce lower levels of smog-forming emissions (such as nitrogen oxides), other pollutants harmful to human health, and greenhouse gases . Energy Security: Because almost all U .S . electricity is produced from domestic coal, nuclear power, natural gas, and renewable sources, using PEVs instead of conventional vehicles reduces U .S . dependence on imported petroleum . Compliance with Fleet Requirements: PEVs can help fleets comply with federal, state, and local trans- portation policies . In all-electric mode, PEVs produce no tailpipe emissions . PEV life cycle emissions are minimized when their source of electricity comes from nonpolluting resources like wind and sunlight . Photo from Atlantic County Utilities Authority, NREL/PIX 18311 Plug-In Electric Vehicle Handbook for Public Charging Station Hosts6 If you want to establish a charging station, you need to know about electric vehicle supply equipment (EVSE, Figure 1). There are various types of EVSE —which differ based on communication capabilities and how quickly they can charge a vehicle — and EVSE can be installed at homes, workplaces, private fleet facilities, and public sta- tions. This section describes the typical EVSE options. Types of Charging Equipment (EVSE) EVSE is the equipment used to deliver electrical energy from an electricity source (such as the electricity running to the electrical outlets at a business) to a PEV. EVSE communicates with the PEV to ensure that an appropriate and safe flow of electricity is supplied. Charging Basics Typical Charging Rates The rate at which charging adds range to a PEV depends on the vehicle, the battery type, and the type of EVSE . The following are typical rates for a light-duty vehicle: Level 1: 2 to 5 miles of range per hour of charging Level 2: 10 to 20 miles of range per hour of charging DC fast charging: 60 to 80 miles of range in 20 minutes of charging Figure 1. A Chevy Volt charges up with public Level 2 EVSE at Los Angeles International Airport . Photo from Coulomb Technologies PEV Availability As of the time this handbook was written, only a few light-duty PEVs were commercially available. PEV technology is just beginning to make inroads into the U.S. vehicle market, but the number of avail- able vehicles is predicted to grow quickly. For com- parison, only two HEV models were available in the late 1990s, compared with 29 models today. To find currently available PEVs, use the AFDC Light-Duty Vehicle Search (www.afdc.energy.gov/afdc/vehicles/ search/light). Learn about anticipated PEV introduc- tions from the Electric Drive Transportation Associa- tion (www.electricdrive.org) and FuelEconomy.gov (www.fueleconomy.gov/feg/phevnews.shtml and www.fueleconomy.gov/feg/evnews.shtml ). A larger number of medium- and heavy-duty PEV models are currently available, most of which are EVs. Applications include delivery trucks, step vans, transit and shuttle buses, and utility trucks. To find currently available medium- and heavy-duty PEVs, use the AFDC Heavy-Duty Vehicle and Engine Search (www.afdc. energy.gov/afdc/vehicles/search/heavy). In addition to a limited number of PEV models, early PEV introductions (starting in 2010) have been limited to select geographic areas to match dealer and service preparation. However, it is expected that at least some PEVs will soon be available from select dealerships in all 50 states. Because of the popularity and limited initial production of PEVs, there may be a wait time involved in obtaining these vehicles. Plug-In Electric Vehicle Handbook for Public Charging Station Hosts 7 EVSE for PEVs is classified into several categories by the rate at which the batteries are charged. Two types — Level 1 and Level 2 — provide alternating- current (AC) electricity to the vehicle, with the vehicle’s onboard equipment (charger) converting AC to the direct current (DC) needed to charge the batteries. The other type — DC fast charging — provides DC electricity directly to the vehicle. Charging times range from less than 30 minutes to 20 hours or more, based on the type or level of EVSE; the type of battery, its energy capacity, and how depleted it is; and the size of the vehicle’s internal charger. EVs generally have more battery capacity than PHEVs, so charging a fully depleted EV takes longer than charging a fully depleted PHEV. Many medium- and heavy-duty PEV manufacturers are adopting light-duty charging standards or com- mercially available standards developed for other uses. However, some manufacturers are introducing alter- native charging configurations in their medium- and heavy-duty PEVs, so EVSE options and performance may be different for these vehicles. Level 1 Level 1 EVSE provides charging through a 120-volt (V) AC plug and requires electrical installation per the National Electrical Code. Most, if not all, PEVs will come with a Level 1 EVSE cordset so that no additional charging equipment is required. On one end of the cord is a standard, three-prong household plug (NEMA 5-15 connector). On the other end is a J1772 standard con- nector (see the Connectors and Plugs section on page 8), which plugs into the vehicle. Level 1 typically is used for charging when there is only a 120-V outlet available, such as at some residential locations. Based on the battery type and vehicle, Level 1 charging adds about 2 to 5 miles of range to a PEV per hour of charging time. Level 2 Level 2 EVSE can easily charge a typical EV battery overnight, and it will be a common installation for home, workplace, fleet, and public facilities. Level 2 EVSE offers charging through a 240-V (typical in residential applications) or 208-V (typical in commer- cial applications) electrical service. These installations are generally hard-wired for safe operation (although a wall plug connection is possible). Level 2 EVSE requires installation of charging equipment and a dedicated circuit of 20 to 80 amp (A) depending on the EVSE requirements (Figure 2). Level 2 equipment uses the same connector on the vehicle as Level 1 equipment. Based on the battery type, charger configuration, and circuit capacity, Level 2 charging adds about 10 to 20 miles of range to a PEV per hour of charging time. DC Fast Charging DC fast-charging EVSE (480-V AC input to the EVSE) enables rapid charging at sites such as heavy traffic cor- ridors and public fueling stations (Figure 3, next page). A DC fast charger can add 60 to 80 miles of range to a PEV in 20 minutes. Inlet Connector Utility 240-V AC Cord EV Coupler EVSE Control Device Battery Charger Figure 2. Level 2 charging schematic . Source: eTec (2010), Electric Vehicle Charging Infrastructure Deploy- ment Guidelines for the Oregon I-5 Metro Areas of Portland, Salem, Corvallis and Eugene. EV Project publication (www.theevproject.com/ documents.php). Illustration by Dean Armstrong, NREL Plug-In Electric Vehicle Handbook for Public Charging Station Hosts8 Inductive Charging Inductive-charging EVSE, which uses an electromag- netic field to transfer electricity to a PEV without a cord, is still being used in some areas where it was installed for EVs in the 1990s. Currently available PEVs cannot use inductive charging, although SAE Interna- tional is working on a standard that may apply to PEVs in the future. Connectors and Plugs Most modern EVSE and PEVs have a standard con- nector and receptacle based on the SAE J1772 stan- dard developed by SAE International (Figure 4). Any vehicle with this receptacle can use any Level 1 or Level 2 EVSE. All major vehicle and charging system manufacturers support this standard, which should eliminate drivers’ concerns about whether their vehicles are compatible with available charging infrastructure. Most currently available PEVs that are equipped to accept DC fast charging are using the CHAdeMO con- nector, developed in coordination with Tokyo Electric Power Company, which is not standard in the United States. Manufacturers may offer the CHAdeMO DC fast charge receptacle (Figure 5) as an option on fast- charge capable vehicles until a standard is in place. SAE International is also working on a “hybrid connector” standard for fast charging that adds high-voltage DC power contact pins to the J1772 connector, enabling use of the same receptacle for all levels of charging. Figure 4. The standard SAE J1772 EVSE connector fits into the standard SAE J1772 receptacle . Photo by Andrew Hudgins, NREL/PIX 17634 DC Fast Charging Inlet DC Fast Charging Connector Utility 480-V 3-Phase Cord EV Coupler EVSE Charger Battery Figure 3. DC fast charging schematic . Source: eTec (2010). Electric Vehicle Charging Infrastructure Deploy- ment Guidelines for the Oregon I-5 Metro Areas of Portland, Salem, Corvallis and Eugene. EV Project publication, www.theevproject.com/ documents.php. Illustration by Dean Armstrong, NREL Figure 5. The standard J1772 receptacle (right) can receive charge from Level 1 or Level 2 equipment . The CHAdeMO DC fast charge receptacle (left) uses a different type of connector . Photo by Andrew Hudgins, NREL/PIX 19558 Plug-In Electric Vehicle Handbook for Public Charging Station Hosts 9 Now that you know the basics about PEVs and charg- ing infrastructure, this section helps you explore the benefits and costs of hosting a charging station.1 To tailor this benefit-cost exploration to your situation, use the Rocky Mountain Institute’s Project Get Ready Charging Infrastructure Tool, available at www.rmi.org/ pgr_resources#infrastructure. Charging Station Benefits There are many benefits to owning or hosting a charg- ing station, which depend on your site characteristics as well as your goals and values. For example, a retail business may host a charging station to increase cus- tomer visits and revenue, whereas a municipality may host a station for the public health benefits associated with increased PEV use. Each benefit in the follow- ing list is — or may become — available to one or more types of station host. Customer Attraction and Retention, Corporate Branding Offering charging is a direct way to attract and retain new, PEV-driving customers. In addition, many con- sumers believe it is important to purchase products with environmental benefits and to frequent environ- mentally responsible companies. Hosting a charging station is a highly visible way to state your organiza- tion’s environmental values, which may help contribute to a “green” image that attracts and retains customers who share these values. User Charging and Parking Fees Charging-station hosts have the opportunity to gener- ate revenue directly from people who use their services. Although the selling of electricity by non-utility organi- zations is prohibited in most parts of the United States, there are various ways to collect revenue for charging, such as subscription-based, pay-per-charge, and pay- for-parking systems. Using these types of systems typi- cally requires installation of advanced EVSE products. Employee Attraction and Retention Companies that offer charging may be able to attract and retain employees who want to charge PEVs during the day. In addition, it is very important to many employ- ees — even those who don’t drive PEVs — that their employers are proactive with transportation planning. Benefits and Costs of Hosting a Charging Station 1. This discussion of benefits and costs is primarily drawn from Rocky Mountain Institute (2009). Plugging In: A Stakeholder Investment Guide for Public Electric-Vehicle Charging Infrastructure (www.rmi.org/ pgr_resources#infrastructure) and BC3 (2011). Electrify Your Business: Moving Forward with Electric Vehicles—A Bay Area Business Guide (www.bc3sfbay.org/ev-guide-for-businesses.html). See those reports for additional details. Raleigh, North Carolina, is among the many U .S . cities installing EVSE in public places . Photo from Kathy Boyer, Triangle Clean Cities Coalition, NREL/PIX 18520 Plug-In Electric Vehicle Handbook for Public Charging Station Hosts10 Fleet Cost Savings An organization may want to serve its own fleet with charging stations in addition to serving the public. A PEV fleet can realize substantial operating- cost savings. Advertising Opportunities Each time a PEV driver visits a charging station is an opportunity to advertise to that driver. A station host could advertise its own products or services in this way or sell advertising space to another organization. Contribution to LEED Certification Installing a charging station contributes toward attain- ing LEED (Leadership in Energy and Environmental Design) certification. LEED is an internationally recog- nized system for rating the energy and environmental performance of buildings. Becoming LEED certified may contribute to improving an organization’s image and thus attract environmentally conscious customers and employees. Value of Avoided Carbon Emissions With a growing number of local and regional carbon- reduction policies, charging station owners may be able to benefit from the value of carbon emissions offset by their stations. Improved Public Health Governments have a responsibility to protect public health, and facilitating the pollution-reduction benefits of PEVs (depending on the source of electricity) by hosting charging stations can contribute to this aim. Increased Energy Security Many station owners have an interest in promoting the energy-security benefits of PEVs by making charg- ing stations available. See the Why Drivers Choose PEVs section. Charging Station Costs The costs of owning and operating a charging station include equipment, installation, maintenance, and electricity costs. You can reduce these costs by taking advantage of discounts and incentives. Equipment EVSE products vary in the types of features they offer and the corresponding prices.2 Prices shown here are for equipment only and do not include installation costs. The price of Level 2 EVSE is approximately $1,000 to $7,000 (before incentives) depending on the level of sophistication. The most basic Level 2 products have only standard safety features and status lights. More advanced, “smart” Level 2 products have features such as enhanced displays, charging timers, commu- nications capabilities, and keypads. “Intelligent” or networked Level 2 products have enhanced durability and ergonomics as well as features like payment card readers, billing software, advanced displays, wireless communication, automated diagnostics, computer- controlled power flow, internal metering, and smart- grid compatibility. DC fast-charging products are similar to intelligent or networked Level 2 products but cost substantially more (typically $20,000 to $50,000) because of the additional hardware require- ments associated with their high-power operation. However, manufacturers are working to decrease costs substantially. Public charging stations that incorporate renewable energy, such as these solar panels, can be particularly appealing to environmentally conscious drivers . Photo from IKEA Orlando, NREL/PIX 18709 2. This discussion is primarily drawn from Rocky Mountain Institute (2009). Plugging In: A Stakeholder Investment Guide for Public Electric-Vehicle Charging Infrastructure (www.rmi.org/pgr_ resources#infrastructure) and BC3 (2011). Electrify Your Business: Moving Forward with Electric Vehicles—A Bay Area Business Guide (www.bc3sfbay.org/ev-guide-for-businesses.html). Plug-In Electric Vehicle Handbook for Public Charging Station Hosts 11 Installation EVSE installation costs vary considerably, so be sure to do your homework and get a number of price quotes before moving forward. For example, the City of Houston reported installation costs of $860 to $7,400 per EVSE unit, not including the cost of the units them- selves.3 Factors affecting the cost (and installation time) include the number of circuits and EVSE units installed, indoor versus outdoor installation, required electri- cal upgrades, required ventilation, and the use of DC fast-charging EVSE. If required, trenching and adding electrical service or panels add the most cost. Total Installed Cost Estimates Various organizations have estimated the total cost of installing a typical public charging station, including equipment and installation costs. One organization’s estimate is $15,000 to $18,000 for a Level 2 station like the one shown in Figure 6; for a DC fast-charging station, the estimate increases to $65,000 to $70,000.4 Another’s estimate is $12,000 for a station with one Level 2 EVSE unit (plus $4,000 to $8,000 per additional unit) and $45,000 to $100,000 or more for a station with one DC fast-charging EVSE unit.5 These prices are expected to trend downward as EVSE production volumes increase. Maintenance Typically, there are relatively few EVSE maintenance requirements. In general, the charging cord should be stored securely so it is not damaged, the accessible EVSE parts should be checked periodically for wear, and the system should be kept clean. See the EVSE man- ufacturer’s guidelines for specific requirements. Periodic inspection, testing, and preventive maintenance by a qualified electrical contractor may be recommended. One estimate of annual maintenance costs ranges from $25 to $50 per EVSE unit.6 PEV parking signs EVSE location Wheel stop Figure 6. Example public charging station design showing EVSE, wheel stop, and sign locations . Source: eTec (2010), Electric Vehicle Charging Infrastructure Deployment Guidelines for the Oregon I-5 Metro Areas of Portland, Salem, Corvallis and Eugene. EV Project publication, www.theevproject.com/documents.php. Illustration by Dean Armstrong, NREL 5. From BC3 (2011). Electrify Your Business: Moving Forward with Electric Vehicles—A Bay Area Business Guide (www.bc3sfbay.org/ ev-guide-for-businesses.html). 6. From Rocky Mountain Institute (2009). Plugging In: A Stakeholder Investment Guide for Public Electric-Vehicle Charging Infrastructure (www.rmi.org/pgr_resources#infrastructure). 3. See the Project Get Ready website (www.rmi.org/pgr_resources# infrastructure). 4. Estimates and figure from eTec (2010). Electric Vehicle Charging Infrastructure Deployment Guidelines for the Oregon I-5 Metro Areas of Portland, Salem, Corvallis and Eugene. EV Project publica- tion (www.theevproject.com/documents.php). Plug-In Electric Vehicle Handbook for Public Charging Station Hosts12 such as convenience stores, coffee shops, drug stores, and fast food restaurants. Types of Station Hosts This section explores considerations relevant to several potential station owners and hosts.7 These are only examples. Many other organizations and locations could host charging stations as well. Retail Stores Retail stores can reap many of the benefits discussed in the Charging Station Benefits section, including cus- tomer and employee attraction and retention, corporate branding, user charging and parking fees, fleet cost savings, advertising opportunities, and contribution to LEED certification. Each retailer must decide which benefits are most important and design its station and business model accordingly. For example, some may offer free charging to maximize customer attraction, whereas others may generate revenue directly via charg- ing or parking fees. Electricity Electricity costs will depend on the type of EVSE installed at a charging station as well as the amount and timing of PEV charging. For example, a station at a retail store might charge vehicles for short periods that include peak hours, i.e., the hours at which the utility may charge the highest electricity rate. On the other hand, a parking- garage station might charge vehicles for longer periods covering peak and off-peak hours. It is important to discuss the effects of PEV charging on electricity rates and loads with your utility. The advanced capabilities of some EVSE products can be useful for optimizing load management. In general, charging-station electricity costs are lower than equipment and installation costs.7 Discounts and Incentives Discounts and incentives can lower charging station costs. You may be eligible for incentives from the state, city, or utility. To find current incentives, search the AFDC’s Federal and State Incentives and Laws data- base (www.afdc.energy.gov/afdc/laws). For even more information about incentives in your area, contact your local Clean Cities coalition (www.cleancities.energy.gov), state energy office (www.naseo.org/members/states/ default.aspx), and utility. Charging Station Locations and Hosts The AFDC’s Federal and State Incentives and Laws database lists currently available incentives that can reduce the cost of EVSE. Various business and government sites are suitable for hosting a charging station. An ideal station location is convenient and highly visible to a large number of potential or actual PEV drivers. It is also important to align the location and capabilities of the EVSE with the characteristics of the drivers visiting the station and the goals of the station host. For example, visitors to a retail store may park for several hours while shopping, and encouraging an extended stay benefits the business. Thus, Level 2 charging, which provides a substantial charge over several hours, is well suited to retail stores as well as other locations with similar characteristics, such as restaurants, theaters, hotels, shopping malls, and museums. Level 2, or even Level 1, charging may be appropriate to long-term-parking locations, such as office parks, airports, parking garages, and parking lots. Stations with DC fast charging are most suitable for places where drivers park for less than a half hour, 7. This discussion is largely summarized from Rocky Mountain Institute (2009). Plugging In: A Stakeholder Investment Guide for Public Electric-Vehicle Charging Infrastructure (www.rmi.org/ pgr_resources#infrastructure). Plug-In Electric Vehicle Handbook for Public Charging Station Hosts 13 Parking Garages Because they already charge customers for parking, parking garages are ideally situated to generate revenue directly from PEV-driving customers. In addition, the existing electrical wiring and structure (e.g., walls and low ceilings) of many garages can reduce station instal- lation complexity and cost. Office Parks As noted in the Charging Station Benefits section, charging stations can help companies attract and retain employees, enhance “green” corporate branding, and serve their own fleet of PEVs. Employees based at office parks are likely to charge for several uninterrupted hours consistently, which should make charging station use relatively predictable. Utilities Utilities have a vested interest in guiding the develop- ment of PEV charging infrastructure, and they are implementing various charging-related strategies. Utilities that are not required to decouple electric- ity sales may receive direct financial benefits from increased PEV charging and may even establish their own charging stations. “Smart-charging” incentives provide PEV owners with convenient, low-cost charg- ing in exchange for giving the utility some control over the charging schedule for grid-stabilization purposes. When designing charging strategies, utilities must work within the restrictions created by their state Public Utility Commissions. Home Owners’ Associations Like office parks, multi-family housing units host long- term parking. Level 2 or even low-cost Level 1 EVSE may be appropriate for meeting overnight charging needs. The presence of charging stations could add value to the residences and entice environmentally conscious buyers. However, because not all residents benefit directly from the charging stations, home owners’ associations have to determine how to distribute the costs equitably. Governments Government entities have led the early development of PEV charging infrastructure. Although governments install charging stations to benefit their jurisdictions rather than generate profits, they may charge fees as a way to offset costs of station installation and operation. Existing Station Network When thinking about establishing a charging station, knowing the location of existing stations is important. Although the current availability of public charging sta- tions is limited, it is increasing rapidly. Publicly and pri- vately funded projects are accelerating the deployment of public stations, including several supported by the U.S. Department of Energy. For more information, visit the AFDC’s Deployment page (www.afdc.energy.gov/ afdc/vehicles/electric_deployment.html ). To find charging stations near you, visit the AFDC’s Alternative Fueling Station locator (www.afdc.energy.gov/afdc/fuels/stations. html ), or access the locator with a mobile device at www. afdc.energy.gov/afdc/locator/m/stations. Some fleets with PEVs may make their EVSE available to the public, while other fleets may charge their PEVs using private EVSE and public charging stations . Photo from Southern California Edison, NREL/PIX 19664 Plug-In Electric Vehicle Handbook for Public Charging Station Hosts14 equipment, installation, and maintenance costs and manages the logistics in return for lease payments or a share of the station’s revenue. This model minimizes the host’s upfront costs and administrative responsibilities. For example, a retail business wanting the customer- attraction benefits of hosting a station without handling all the details might contract with a third party to install and operate a station on its property. Ownership and Payment Models Today, many charging stations are publicly funded and offer free charging to encourage early adopters of PEVs. However, many public stations will evolve toward a pay-for-use system as PEVs become more mainstream. In most parts of the United States, only utilities are allowed to sell electricity directly, so most non-utility- owned stations likely will charge a service fee instead of charging for electricity use. A number of payment models are being explored, all designed to make paying for charging simple and convenient. Drivers might subscribe to a charging service, swipe their credit card, enter a charging account number, or insert coins or bills into a meter to charge their PEVs. In many cases, drivers will only be charged a single fee for parking and charging. “Smart cards” or radio-frequency identifica- tion (RFID) devices programmed with user information enable the station host to collect usage data in addition to payment. Charging station ownership models also vary. Some charging station hosts may purchase, install, and operate stations themselves. This model gives the host or owner control of the station and allows them to keep all revenues. For example, a parking lot owner might buy and operate a pay-for-use charging station as a central part of its business strategy. Other organizations will contract with a third party who pays the station Two Payment Models Coulomb Technologies and NRG Energy exemplify two different charging station payment models . Coulomb supports a network of charging sta- tions — the ChargePoint Network — hosted by various organizations worldwide . For a fee, Coulomb provides turnkey services to collect, process, and forward payments from PEV drivers to the station hosts . This allows each host to set the station’s pricing system based on parameters such as amount of charging time, amount of electricity consumed, time of day, and day of week . For example, a municipal station might set one price per hour of charging during business hours and a second price after hours, while giving free access to municipal vehicles at all times . PEV drivers can pay for charging at these stations with major credit cards or Coulomb’s ChargePass smart card . For more information, visit the Coulomb website (www.coulombtech.com) . NRG Energy’s eVgo charging station network is being deployed initially in the Houston and Dallas/Fort Worth areas . In this model, PEV drivers subscribe to eVgo for a flat monthly fee . The most comprehensive subscription package provides installation of home EVSE, a three-year service agreement, unlimited charging at eVgo network stations, and unlimited charging at home with no additional electricity cost during non-peak hours . Public eVgo stations are hosted at retail, workplace, and multi-family housing locations . NRG manages the station installation and maintenance . Station hosts are responsible for few or no upfront costs but pay a monthly membership fee . For more information, visit the eVgo website (www. evgonetwork.com) . Through its ChargePoint Network, Coulomb Technologies supports charging stations hosted by various organizations worldwide . Photo by Andrew Hudgins, NREL/PIX 17834 Plug-In Electric Vehicle Handbook for Public Charging Station Hosts 15 PEVs, one option is to install a variety of EVSE products at these stations when possible. You can also discuss EVSE options with your electrical contractor and utility. If you choose an EVSE provider before choosing an electrical contractor, you can discuss potential electri- cal contractors with your EVSE provider — they likely will have a preferred-contractor list for your area. A viable EVSE product should be listed by a nationally recognized testing laboratory, such as Underwriters Laboratories or CSA International. Find links to EVSE provider websites on the AFDC’s Related Links page (www.afdc.energy.gov/afdc/related_links.html ). In addi- tion, Plug In America lists EVSE products on its Acces- sory Tracker page (www.pluginamerica.org/accessories). To find licensed electrical contractors trained in EVSE installation, contact the Electric Vehicle Infrastructure Training Program at Info@EVITP.org. In addition, your state’s licensing board likely will provide a list of licensed electrical contractors (though not specifically those that have received EVSE training). Energy Audit Before planning and installing a charging station, it may be useful to have an audit of your site’s entire energy footprint. An audit can identify opportunities for energy savings in your facility, and these savings could be used to offset the increased electricity load associated with adding a charging station. An audit may also help ensure that your station works well in your facility’s energy system. EVSE and Electrical Upgrades For charging stations that will serve multiple vehicles, it is important to project EVSE requirements over several years. If expansion of EVSE use is projected, the addi- tion of extra circuits, electrical capacity, and conduit from the electrical panel to future EVSE locations should be considered. It is less expensive to install extra panel and conduit capacity during initial construction Public charging station installations range from the simple to the complex. Figure 7 (next page) summarizes the processes for installing EVSE at a public station, and the following sections address some of the consider- ations related to establishing and operating public sta- tions.8 As Figure 7 shows, it is important to consult with your utility, governing authority, electrical contractor, PEV provider, EVSE provider, and other stakeholders early in the EVSE installation process. For additional details about installing EVSE, see the Clean Cities Plug-in Electric Vehicle Handbook for Electrical Con- tractors. Also see the Raleigh, North Carolina, public charging station installation video at www.youtube.com/ watch?v=jvPLvsg9y2o. Choosing an EVSE Provider and Electrical Contractor Several companies manufacture and sell EVSE. Some have partnered with a PEV manufacturer to become a “preferred EVSE provider,” so one way people choose EVSE is to use the companies recommended by the manufacturers or dealers of the PEVs that will be served. Because public stations will serve a variety of Installing and Maintaining Charging Stations The Electric Vehicle Infrastructure Training Program is one of the organizations that trains electrical contractors in EVSE installation . Photo from Electric Vehicle Infrastructure Training Program 8. These recommendations are primarily summarized from Pacific Gas & Electric’s Electric Vehicle Supply Equipment Installation Manual (http://pge.com/mybusiness/environment/pge/electricvehicles) and eTec’s Electric Vehicle Charging Infrastructure Deployment Guidelines for the Oregon I-5 Metro Areas of Portland, Salem, Corvallis and Eugene (www.theevproject.com/documents.php). See those documents for additional details. Plug-In Electric Vehicle Handbook for Public Charging Station Hosts16 Figure 7. General process for installing EVSE at a public facility . Source: eTec (2010). Electric Vehicle Charging Infrastructure Deployment Guidelines for the Oregon I-5 Metro Areas of Portland, Salem, Corvallis and Eugene. EV Project publication (www.theevproject.com/documents.php). Utility Considerations 1 . PEV Rate Structure 2 . Availability of Power 3 . Metering 4 . Total Load Management 5 . Smart Grid 6 . Level 2 and/or DC Fast Charging Business Owner Considerations 1 . Quantity of EVSE 2 . Location of EVSE Station(s) 3 . Ownership Concerns 4 . Cost Sharing 5 . Maintenance Responsibilities 6 . User Payment for Service 7 . Vandalism 8 . Lighting/Shelter 9 . Advertisement 10 . Smart Grid/Load Sharing Enthusiasts Considerations 1 . Location 2 . Promotion/Advertising OEM Considerations 1 . Level 2 or DC Fast Charging 2 . Current and Future PEV Needs 3 . Determination of Number of Chargers Required 4 . Determination of Location of Parking Areas 5 . Determination of Electrical Loads 6 . User Payment Options Governing Authority Considerations 1 . Public Planning 2 . Funding/Grant Requirements 3 . Public Siting Locations 4 . Traffic Patterns 5 . Public Street Signage 6 . Other Requirements Contractor Considerations 1 . Site Assessment/Load Calculation 2 . Proximity to Utility Service Panel 3 . Standing Water/Flood Issues 4 . Safety and Accessibility Considerations 5 . Avoidance of Tripping Hazard 6 . Installation Meets Building Code Requirements 7 . Installation Meets Local Zoning Requirements 8 . Additional Lighting Requirements 9 . Load Sharing Options Contractor Considerations 1 . Drawing of EVSE Location 2 . Electrical Plan Including New Circuit 3 . Additional Meter Requirements, if Necessary 4 . Concrete Cutting, Trenching, Landscape Considerations 5 . Contractor Estimate Approving Authority Considerations 1 . All Building Codes Satisfied 2 . Qualified and Certified Contractor Consultation with Utility Consultation with PEV Enthusiasts Consultation with Local Business Owners Consultation with Governing Authority Consultation with PEV and EVSE Suppliers Consultation with Electrical Contractor Utility Service Upgrade Completed Installation Completed, Final Inspection and Approval Site Plan Developed Conduct Installation Obtain Permits PEV Promoter/ Property Owner Plug-In Electric Vehicle Handbook for Public Charging Station Hosts 17 than to modify the site later. Electricity and charging- time needs can be analyzed by estimating electricity- use and time requirements for all the PEVs that will be served. This will enable assessment of electrical- upgrade needs and determination of the appropriate number and type of EVSE units. Whether installing one or many EVSE units, the electrical contractor should conduct a thorough site assessment and load calcula- tion to make a proper and safe determination of service capacity and prospective power needs. If upgrades to your electrical service are required, discuss the process and cost implications with your electric utility as soon as possible. Engineering and Construction Because EVSE installations involve specialty equip - ment and extensive electrical work — in addition to standard civil engineering work — select well-qualified contractors with experience in the relevant engineering and construction areas. The condition and location of existing electrical equipment will determine the com- plexity of the required electrical installations. If the existing electrical system does not support the required EVSE input voltage range, an isolation transformer is required to step electricity down to Level 2 or up to DC fast-charging voltage. To learn more about the types of considerations contractors must address, see the Clean Cities Plug-in Electric Vehicle Handbook for Electrical Contractors. Complying with Regulations Charging station installations must comply with local, state, and national codes and regulations, and instal- lation requires a licensed contractor. Your contractor should know the relevant codes and standards and obtain approval from the local building, fire, envi- ronmental, and electrical inspecting and permitting authorities before installing EVSE. You can learn about codes and standards typically used for U.S. PEV and infrastructure projects on the AFDC’s Codes and Standards Resources page (www.afdc.energy. gov/afdc/codes_standards.html ). To determine which codes and standards apply to your project, identify those that are in effect within your local jurisdiction. Some jurisdictions also have unique ordinances or regu- lations. EVSE is considered a continuous load by the National Electrical Code (NEC). An electrical contrac- tor’s knowledge and application of the current NEC is required for a safe and code-compliant installation. Consult PEV manufacturer guidance for information about the required EVSE and learn the specifications before purchasing equipment and electric services. In many areas, a site installation plan must be submit- ted to the permitting authority for approval before EVSE installation can proceed. A plan describes the use and locations of elements such as electrical system components, hazardous materials, EVSE, lighting, vehicle and pedestrian traffic flow, ventilation, signage and striping, safety and accessibility measures, and landscaping. You may want to work with your contrac- tor to develop the plan. Site and Equipment Considerations The following are some of the site and equipment issues you should consider when installing a charging station. Discuss these and other issues applicable to your specific installation with your contractors, utility, and EVSE provider. Convenience Locate EVSE and associated PEV parking as close as possible to the electric service while accommodating other activities at the site. Keep in mind that PEVs can be parked for hours at a time for charging. Avoiding Hazards Cords and wires associated with EVSE should not inter- fere with pedestrian traffic or present tripping hazards. PEV charging spaces should not be located near poten- tially hazardous areas. Charging stations may soon become a common sight along U .S . streets . Photo from Coulomb Technologies Plug-In Electric Vehicle Handbook for Public Charging Station Hosts18 Ventilation Although most of today’s advanced batteries do not require ventilation during charging, some older types emit gases during charging. If your station will be enclosed, there must be adequate ventilation, which may include installation of fans, ducts, and air han- dlers. Depending on the installation, the NEC may also require ventilation. Verify the requirements with the PEV manufacturer’s documentation. Battery Temperature Limits Because some PEV batteries have operating- and charging-temperature limits, EVSE may need to be located within an enclosed, climate-controlled area in extreme climates. Pooled Water and Irrigation EVSE is designed to operate safely in wet areas. However, users will be more comfortable if it is not located where water pools or where irrigation systems spray. Preventing Impact Curbs, wheel stops, and setbacks should be used to prevent PEVs from colliding with EVSE (Figure 6). However, accessibility issues must also be considered when using these strategies. Vandalism Assess the risk of vandalism and minimize risk through use of preventive strategies, such as motion detectors, security lighting, tamper alarms, locked enclosures, anti-vandalism hardware, and graffiti- resistant coatings. Signage Signs are particularly important for public charging stations. Mark PEV parking/charging areas clearly with distinctive patterns on the ground and signs that can be seen over parked vehicles. Accessibility Evaluate and address requirements for complying with the Americans with Disabilities Act, as well as state, local, and organizational accessibility policies. Compliance measures may include adjusting connec- tor and receptacle heights, cutting curbs, and providing accessible parking spaces. Lighting and Shelter Provide lighting and shelter as necessary for the safety, comfort, and convenience of EVSE users. Lighting should enable EVSE users to read signs and instructions and to operate the EVSE easily. Although not typically required for outdoor-rated EVSE, shelter that blocks rain, snow, and wind can increase convenience and comfort associated with using EVSE. Payment for Charging Services If the station will require payment for charging, a payment system must be established (see the Ownership and Payment Models section). A payment system also can be used to collect data on station use. Some EVSE products have integrated payment and data collection/ communication systems. EVSE products with billing capability (and many others) will require network com- munications. Be sure to verify whether the EVSE needs Ethernet (Cat5 or Cat6) or cell network access and plan accordingly. Aesthetics The aesthetics of charging stations can be important, especially for businesses trying to portray a positive image to customers. Where necessary, landscaping or walls can be used to screen equipment from view. Trouble Reporting Station users who have trouble with the EVSE should be able to report it or contact support. For example, you could post your organization’s telephone number or the number of a service that monitors multiple public stations, or you could direct customers needing help to a specific office or store location. Plug-In Electric Vehicle Handbook for Public Charging Station Hosts 19 Clean Cities Can Help If you need help with your PEV project, contact your local Clean Cities coordinator by visiting www.cleancities.energy.gov . You now know the basics about PEVs and public charging stations. In a time of volatile petroleum prices and heightened environmental concerns, many people may see PEVs as a convenient way to reduce driving costs while being environmentally responsible. The number of available PEV models and the number of PEVs on the street are growing rapidly, as is the need for additional charging stations. Now may be a good time to consider hosting a charging station and becoming part of the electric transportation future. To keep up with new PEV developments, visit the AFDC (www.afdc.energy.gov/afdc/vehicles/electric. html ) and FuelEconomy.gov (www. fueleconomy.gov) frequently. Electrifying the Future Illustration from iStock/15052491 Clean Cities Technical Response Service 800-254-6735 technicalresponse@icfi.com Prepared by the National Renewable Energy Laboratory (NREL), a national laboratory of the U .S . Department of Energy, Office of Energy Efficiency and Renewable Energy; operated by the Alliance for Sustainable Energy, LLC . DOE/GO-102012-3275 • April 2012 Printed with a renewable-source ink on paper containing at least 50% wastepaper, including 10% post consumer waste . Cover photos clockwise from right: by Pat Corkery, NREL/PIX 18182, from iStock/17799403, from iStock/16703194 Nissan Leaf electric vehicle by Mariordo59 Top electric vehicle links Seattle City Light Single & Multi-family charging stations Client Assistance Memo (DPD) Washington Electric Vehicle Laws and Incentives Puget Sound Clean Cities Coalition The EV Project Climate Protection Energy Green Building Transportation Electric Vehicles Food Waste and Toxics Reduction Water and Urban Trees Learn and Lower Your Impact Your Greener Government Community Connections Plans and Documents Electric Vehicles Seattle is one of a handful of cities participating in the nation’s largest electric vehicle demonstration, the EV Project. With the help of millions in federal stimulus dollars, the City of Seattle is collaborating with Puget Sound local governments, businesses, non-profits, and electric vehicle enthusiasts, to create a robust regional charging infrastructure for EVs. Promoting electric vehicles an important part of the City’s efforts to reduce greenhouse gases from cars and trucks on Seattle’s roads, which make up 40 percent of our city-wide footprint and are the single largest source of emissions. To reduce our transportation footprint, the City is pursuing a two-part strategy. The first part focuses on increasing transportation choices so that residents and businesses can walk, bike, or take transit. The second part focuses on improving vehicle efficiency so that the remaining cars and trucks on Seattle roads have a smaller greenhouse gas impact. Plug-in electric vehicles are an exciting step forward in efficiency, especially here in Seattle where the vehicles will be powered by the clean energy of Seattle City Light . In fact, if the average Seattleite switched to an electric car, it would eliminate more than four tons of greenhouse gas emissions every year. Read the FAQ or visit some of the other pages below. Getting Seattle Plug-In Ready The City has been working to ensure that Seattle is “plug-in ready.” The Plug-in Ready Team is working to: Streamline the permitting process and provide consumer information for installing home and commercial charging stations. Identify code changes for new construction to make it easier to install charging stations. Developing charging stations on City property for city fleets and public charging. Coordinate with surrounding cities and King County to develop a regional EV infrastructure strategy. Explore market demand for plug-in vehicles, and the infrastructure needs for likely EV purchasers. Provide education on the benefits of electric vehicles. Funding for EV infrastructure Funding for Seattle’s EV charging infrastructure is coming from federal stimulus funds. On the private property side, ECOtality North America is working on installation of charging stations for homes and at local businesses. For public property, the Puget Sound Clean Cities Coalition was awarded funds for the City of Seattle to install up to 50 EV charging stations for the City’s fleet and for public access on public property, City of Seattle Fleets Progress on Electric Vehicles 44 all-electric vehicles replaced less efficient vehicles since mid-2011 Over 1,600 gallons of fuel saved as a result Lifetime savings of $3-4K with EV over hybrid or conventional vehicle Seattle awarded 2010’s Top Green Fleet award from 100 Best Fleets Departments | Services | Staff Directory | My.Seattle.Gov Seattle.gov This Department Page 1 of 2Office of Sustainability and Environment -Built Environment 4/30/2013http://www.seattle.gov/environment/ev.htm such as the Seattle Center and the Central Library garages. Electric vehicle links Seattle Electric Vehicle Association The EV Project Western Washington Clean Cities EV Guide by Western Washington Clean Cities King County - Plug and Ride Electric Vehicle Pilot Project Electric Drive Washington Washington Electric Vehicle Laws and Incentives How an Electric Vehicle Works US Department of Energy – Alternative Fuels and Advanced Vehicles EV icon by Washington Dept. of Transportation. Climate Protection | Energy | Built Environment | Transportation | Food | Waste and Toxics Reduction Water and Urban Trees | Lower Your Impact | Community Connections | Plans and Documents Navigate to: Seattle.gov Home Page Business In Seattle Living in Seattle Visiting Seattle City Services Mayor's Office City Council City Departments My.Seattle.Gov We're Here to Help... Questions / Complaints FAQs Employee Directory City Customer Service Call (206) 684-CITY (2489) Follow Us CityLink Blogs Social Media Sites Data.seattle.gov © Copyright 1995-2013 City of Seattle Privacy and Security Policy Page 2 of 2Office of Sustainability and Environment -Built Environment 4/30/2013http://www.seattle.gov/environment/ev.htm Home >Charging Share BMW charging Charging Locator Chevrolet Volt Chevy Volt CODA Sedan Events Fit EV Fleets Ford Focus Electric Grid Electricity hands free Honda Incentives for EV Buyers Mitsubishi i mobile Nissan LEAF pluginday Prius Range RAV4 roadmap Safety Showroom Tesla Tesla Model S Tesla Roadster Toyota Transit Connect Electric Vehicles Connect CHARGING Charging Overview Charging Station Locator Home Charging Workplace Charging Public/Commercial Charging Fleet Charging Utility Resources Charging Safety and Standards Charging Station Showroom Find an EV Charger Public/Commercial Charging Charging your electric vehicle, when needed, at one of the growing number of public and commercial charging stations is easy and cost- effective. Prices for public charging are at the discretion of the charging site owner, within limits established by utility regulators. Payment methods include subscriptions, credit and debit cards, pre-paid smart cards, radio or infrared identification tags, cash or another payment method. Charging can be included as part of the parking fee. It’s sometimes free at retail or mall locations, to encourage plug-in car owners to shop at their stores. Power While You Shop, Play or Explore PEVs can easily be charged at a public charging station while you shop, attend events or see the sights. At a 240-volt electric charging station, plug-in hybrids and extended-range vehicles can take one to four hours to charge, depending on how much battery power has been expended. Local governments are planning to install charging stations in parking garages, shopping centers and at curbsides. The number of public and commercial charging stations is expected to grow exponentially in the next few years. The U.S. Department of Energy has provided more than $115 million to fund construction of charging infrastructure in major cities in seven regions of the U.S. In conjunction with Nissan and General Motors, the EV Project includes provisions for public and private 240-volt electric power charging stations, along with roadside fast-charging units, in anticipation of the rapid growth of plug-in vehicles. Utilities and municipal governments across the U.S. and Canada are also undertaking initiatives to support electric vehicles. Charging in the Fast Lane Advances in technology are making the possibility of faster charging at public and commercial charging stations a reality. Fast-charging technology for electric vehicles can recharge batteries four to six times faster than conventional chargers. Once safely connected to a fast charger your vehicle controls the charging process, determining the charging rate. Additional Questions about PEV Public and Commercial Charging Stations 1. How much will it cost to charge my vehicle at a public or commercial charging station? The cost of public charging is determined by the charging site owner, usually within limits established by utility regulators or municipal authorities. Some public stations may provide free electric vehicle charging to attract customers to nearby businesses. Electric car owners may be able to pay by credit or debit card, a service subscription, pre-paid smart card, radio or infrared identification tags, cash or another payment method. 2. How can I find a public charging station in my area? Online resources, such as Clean Car Maps, direct drivers to charging stations in their area. Many new tools are being developed that will locate compatible charging stations, provide cost information and pay for charging on your mobile phone or PDA. For some vehicles, onboard services provided by the automaker will locate charging stations for you. For more information on PEV home charging, charging stations and charging costs, please visit these organizations’ websites: •The Electric Drive Transportation Association •Clean Car Maps GET STARTED DRIVE ELECTRIC! ELECTRIC CARS CHARGING INCENTIVES FAQ & GLOSSARY NEWS & EVENTS ABOUT RESOURCES Search Page 1 of 2Public/Commercial Charging 4/11/2013http://www.goelectricdrive.com/index.php/public-commercial-charging Make the most of your energy Management of electric vehicle fleet charging March 2011 / White paper by Maël Cazals and Gilles Vidalenche Table of contents Introduction .............................................................................................. p 2 What is an electric vehicle? ..................................................................... p 4 How are electric vehicles recharged? ...................................................... p 5 What to use as a basis for management of an electric vehicle fleet ......... p 7 How are electric vehicles made available? ... .......................................... p 8 ... Whilst at the same time managing your energy bill? ............................ p 9 Recharging vehicles outside the company .............................................. p 11 Associated services ................................................................................. p 12 Conclusion ............................................................................................... p 13 Glossary .................................................................................................. p 14 Introduction White Paper | 02 Management of electric vehicle fleet charging In France, company vehicle fleets represent approximately a third of the overall number of vehicles registered, i.e. 850,000 vehicles in 2010(1). With no gas emission, no discharge of particles and silent operation, the electric vehicle offers an effective, concrete solution to reduce the ecological footprint of transport. It forms the last missing link in the panorama of sustainable urban mobility (train, tramway, bus, bicycle) and perfectly matches the needs of drivers travelling less than 20 km daily, essentially within urban areas. This average distance covered each day corresponds to the needs of private individuals using their vehicles for the home-work run and also to most trips made using vehicles from company fleets. Using an electric vehicle regularly requires safe, easy-to-use charging systems. These charging infrastructures must also allow the user to charge his vehicle during his usual journeys and not force him to stop specifically to do this. The innovative concept of electric vehicle charging is the possibility to charge it where the user usually parks instead of having to stop specially to charge it as is the case for vehicles with combustion engines which need to stop in service stations. Environmental initiatives developed on a nation-wide scale are raising the awareness of companies to the importance represented by the arrival of more ecological shared, alternative and multi-mode means of transport. For this reason several large French companies, the State and the local authorities have undertaken to acquire between 50,000 and 100,000 electric vehicles by 2015. This purchasing process will subsequently be widened to include companies with smaller fleets. The electric vehicle is more environmentally-friendly than vehicles with combustion engines and provides an effective, concrete solution to reduce the impact of transport on the environment, particularly for short urban or suburban journeys. However, implementing electric vehicles in a company fleet requires the following conditions to be fully met: • guarantee electric vehicle availability, • set up a fleet management system or integrate an existing one, • have an optimised charging infrastructure allowing efficient energy management. The key factors for successful electric vehicle fleet management are therefore: • set up efficient vehicle fleet management: journey organisation, rotation and sharing of vehicles, consumption monitoring, battery autonomy, etc. • availability of a charging infrastructure: the company must ensure that the employee has access to a space and a charging station for his vehicle. • Include charging station energy management in the management of the overall energy efficiency of the building. (1) source - Ministry for Ecology, Sustainable Development, Transport and Housing Electric vehicle fleets What is an electric vehicle? White Paper | 04 Management of electric vehicle fleet charging The motor The car is generally fitted with one or more electric motors with a total power ranging from 15 to 100 kW depending on the size, usage and desired performance. E.g. 48 kW (65 hp.) for a small 4-seater saloon. Batteries and range The battery bank supplies energy provided: • either by recharging from an external source via cable • or by vehicle deceleration, where the engine works as a generator. The battery capacity is within a range of 5 to 40 kWh, with a total voltage of between 300 and 500V. 1 4 2 3 1 > Connection plug for charging 2 > Built-in charger 3 > Battery bank for energy storage 4 > UPS and traction motor(s) The vehicle's range depends directly on the battery’s capacity and also on the type of journey (flat, varied, urban, etc.), the driving mode and the accessories used (headlights, heating, air-conditioning, windscreen wipers, other accessories). The manufacturers announce an average driving range of 150km. White Paper | 05 Management of electric vehicle fleet charging Charging modes Mode 2: connection to a domestic socket Connection of the electric vehicle to the building's electrical distribution system via connector bases which plug into domestic single phase or three phase AC sockets with earth and power supply conductors. A charging control function is either built into the plug or into a unit fitted to the cable. Charging is restricted to 10A. Mode 3: connection to a specific socket Connection of the electric vehicle to the building's electrical distribution network via connector bases which plug into specific sockets on a dedicated AC circuit. A charging control function is built into the plug base. For reasons of safety, Schneider Electric only offers this solution. (Communicating checking device built into the cable) COMACdomestic socket ACTerminal (Checking device built into the charging stations) Mode 3 guarantees users the highest level of safety and the best performance. Danger may arise from: • a faulty system (damaged cable, faulty or aging installation, etc;) • mishandling by users (a child putting its fingers into the socket, etc.) • incorrect usage (the user plugs the connector into the wrong socket, etc.) In mode 3, the personal protection functions (e.g. differential circuit breaker) are in the fixed part, whereas in mode 2 they are built into the cable. This means that in mode 2, if the cable is damaged, there is no guarantee that these functions will not be affected. In all cases, property protection (e.g. lightning conductor) is not built into the cable. Two wires in the charging cable establish communication between the charging station and the charger in the car. The purpose of the information exchanged is: • For the charging station: to only establish the voltage if the vehicle is connected, it is correctly connected to the charging station earth and is ready for charging. • For the charger: to restrict the current called to the maximum authorised by the charging station (only mode 3). Pilot wire How are electric vehicles charged? Mode 4: DC connection Connection of the electric vehicle to an external charger fitted with a specific cable and delivering direct current. The charger incorporates the control function and electrical protection. DC White Paper | 06 Management of electric vehicle fleet charging Time to recharge Time to fully charge (hours) Power available at charging station outlet 10 A 16 A Mode 2 32A single phase 32A three phase Mode 3 Mode 4 125 A 1 2 3 4 5 6 7 8 10-12 h 6-8 h 2-4 h 1-2 h 15-20 mn 9 10 11 12 The time required for optimum charging of the vehicle's battery is directly linked to the electric power injected into the vehicle. If the vehicle is connected to a domestic socket on the building's standard electrical distribution network (mode 2), charging will be restricted to 10A, which means a longer time to charge it (around 10 to 12 hours). If it is connected to a dedicated electrical circuit (mode 3), the time to charge is between 1 hour (three-phase, 63A) and 8 hours (single-phase, 16A). In addition, quick charging stations (mode 4) delivering 500C/125A in AC allow the battery to be recharged to 80% of its capacity in only 15 minutes. What to use as a basis for management of an electric vehicle fleet White Paper | 07 Management of electric vehicle fleet charging To be more efficient, management of an electric vehicle fleet must take into account different factors regarding the vehicle (battery autonomy, time to recharge, etc.), the building (available energy, power of the installation, etc.) and the company (vehicle availability, cost of operating the vehicles and the infrastructure, etc.). To ensure vehicle availability, the fleet manager: • manages user priority, • manages the rate of occupation of the charging infrastructure, • optimises the energy costs. For this purpose, the fleet manager will need to use a certain number of parameters regarding e.g. • the charging infrastructure (maximum power, electricity contract subscribed to, etc.), • the vehicles (type of vehicle, category, registration,maintenance dates, battery autonomy, etc.), • the charging stations (number of stations, maximum power delivered, charging in progress, vehicle not connected, etc.), • the drivers (profile, identifier, etc.), • the reservation system (date and time of departure and arrival of the vehicle, distance travelled, etc.). In most cases, the daily trips made by employees in a company are less than 100km but have very specific usage constraints: • the vehicles may be used at set times (home-company run, rounds, deliveries, etc.) or the times may be random (on call, emergencies, etc.), • the distance travelled by the vehicles may be short (targeted interventions, breakdown assistance) or very long (vehicle used by a sales rep or for rounds), • the sales rep vehicle departures may be planned in advance or last minute. White Paper | 08 Management of electric vehicle fleet charging How are electric vehicles made available? ... 1 / first come - first served whatever the charge the vehicle still has left The employee leaves his vehicle in a free parking space and connects it up. It immediately starts charging if the power available on the infrastructure allows it. If the power is not available, charging will be deferred. Disadvantages: there is no guarantee that the vehicle will be available when the user wants it as there is no knowing when charging will start and end. Therefore the range of the vehicle is not known when it is taken out. 2 / charging according to the range left in the vehicle. This strategy involves charging the vehicles with the lowest range first. This means the range each vehicle has left must be fed back to the infrastructure. The vehicle with the lowest range will be charged first. Advantage: charging of the vehicles with the lowest charge starts as soon as possible. Disadvantages: there is no guarantee that the vehicle will be available when the user wants it as there is no knowing when charging is supposed to end. Two technical criteria must be taken into account: • the power available on the installation to charge the vehicles, • the maximum charging power of the vehicle (normal charging 3kW, express charging 22kW, quick charging 43kW). Two approaches can thus be adopted when setting up the infrastructure: • a charging infrastructure allowing all the vehicles to be charged at the same time. 3 / range required for the intervention The vehicle charging strategy depends on the information in the vehicle reservation system (time slots for use, mission, etc.). The following information is required: • range remaining on the vehicle, • range required for the mission, • the date when the vehicle will be made available. The automatic system managing the charging station infrastructure will distribute the power of the installation to satisfy the scheduled reservations. Advantages: the vehicles are guaranteed to be available at all times. The system takes into account the characteristics of the journey (season, type of journey, preconditioning of the vehicle, length). Disadvantage: a reservation system is required. 4 / group of top priority vehicles This strategy can be used in addition to the previous ones. These are vehicles whose battery must always have a minimum charge. The installation must be capable of charging all the top priority vehicles simultaneously. e.g. utility vehicles intended for urgent interventions or on-call situations. Different strategies can be adopted by the fleet manager: Implementation No system is used to distribute the charging power between the vehicles. The electrical installation is only used for a few hours during the day. This means the infrastructure will be oversized in terms of power and the costs of the electricity contract will be high. • a charging infrastructure allowing the vehicles to be charged by distributing the charging power over time: A system is used to manage the available power. The electricity installation and electricity contract are accurately sized. ... whilst at the same time managing your energy bill White Paper | 09 Management of electric vehicle fleet charging 1 / tariff bands The fleet management system takes into account the energy supplier's tariff bands when charging the vehicles. Two ways of doing this: • disabling charging during certain tariff bands on one, several or all the charging stations. Disadvantages: difficult to combine energy savings with vehicle availability. • spread vehicle charging over the time slots to ensure they are available at the cheapest cost. Advantages: the vehicles will be charged first and foremost during the cheapest time slots. 2 / the source of the energy supplied The fleet management system takes into account information from the energy supplier with regard to the type of energy (low-carbon electricity) depending on the times of day. Two ways of doing this: • disable charging when the energy is not low- carbon on one, several or all the charging stations. Disadvantages: difficult to combine periods of low-carbon energy with vehicle availability. • distribute vehicle charging, restricting charging when the energy supplied is not low-carbon. Advantages: vehicles will be charged first and foremost during low-carbon periods. Optimising operating costs for an electric vehicle fleet depends on several factors. Low-carbon energy is produced in a way which does not generate CO2. The charging infrastructure, the key success factor for electric vehicles Supermarket M MAIL ACDC € EXITShopping centre car parks Charging to 25% minimum in 2 hours Robust, locking, vandal-proof solution. Supervision and charging level services. With or without payment system. Residential garage Charging in 6 to 8 hours Installed by a professional with guaranteed safety for people and equipment. Residential car parks Charging in 6 to 8 hours Solutions to manage all energy expenses. Private company car parks Charging in 3 to 8 hours Free or paying service for employees and visitors with supervision and video-surveillance. Covered paying car parks Charging to 25% minimum in 2 hours Remote or centrally controlled installations. Road-side parking Charging to 25 % minimum in 2 hours Weather-proof, impact-resistant systems with payment option. Charging in 3 to 8 hours Vehicle eet management and supervision solution to save energy. Car park for vehicle fleet Charging in 15 to 30 minutes A reliable, fast solution in an emergency. Quick charging terminal Charging vehicles outside the company White Paper | 11 Management of electric vehicle fleet charging Although the vehicle is normally charged on the company car park, the vehicle may require charging outside this location. In this case, the different types of charging infrastructure will allow full charging of the vehicle to fit in with the user's habits with regard to places and length of stops. • For long stops (night at home, day at the work place), a full charge of between 6 and 8 hours can be done on a domestic installation or on a car park installation (company). • For shorter stops of 1 or 2 hours (e.g. during lunch or a meeting), the driver can top up his charge on a car park, a shopping centre or at the roadside. • Finally for quick charging lasting 15 to 20 minutes, charging will be carried out in a service station (e.g. in case of emergency).It is possible to install a quick charging station on fleet car parks for ambulances or taxis for example. In this context, the fleet manager will need to have a way of tracing the charges and journeys carried out outside the company to allow him to know the charge of the fleet at any given moment: • what vehicle has been charged? • where did this take place? • what power was delivered? • how much did the charging cost? Associated services Services for the driver Mobile applications communicating with the system database provide information regarding the state of the batteries and allow the electricity consumption of the vehicle to be remotely consulted, give the remaining charging time, the parking time, the level of CO2 saved, the cost of the vehicle per km, including the battery rental. Position determination by smartphone application White Paper | 12 Management of electric vehicle fleet charging Charging management automation Data base Terminals Management interface Services for the electric vehicle fleet manager Reservations management: • ensure each vehicle has the necessary range for the type of missions to be carried out. Vehicle management (administrative, technical and fi nancial management): • electricity consumption of each vehicle • state of health of the battery (age, number of charging cycles carried out, level of charge remaining, etc.) and maintenance calendar. Supervision of stations installed on one or more sites with energy, user and infrastructure management. The charging stations transfer operating information via a hard-wired connection to the cabinet containing the automatic charging management system. The data is stored on a database to be used by the management system which may be located either: • locally: if a system is already operational and adapted for electric vehicle management, • remotely: if operation is off-site or sub-contracted to a service provider. Moreover, the position determination functions available via the vehicle GPS and smartphones allow the range required for the next trip to be calculated, nearby charging stations to be located or the places where the vehicles are parked to be memorised. Conclusion The increasing use of electric vehicle fleets is a response to the political commitment to reducing the carbon footprint of the transport sector. Several car manufacturers already produce 100% electric cars but their inclusion in a company fleet means mobility needs to be radically restructured, particularly with regard to the concept of car-sharing. Suppliers of intelligent charging solutions, aware of the issues linked to the sector, provide their expertise and support companies in the process of integrating electric vehicles into a fleet. Indeed, for the political aims to be put into practice, it is essential for companies that the cost (TCO) of a fleet of electric vehicles should be close or identical to that of a fleet of combustion vehicles. As the initial cost is greater, intelligent management of the charging infrastructure and vehicle availability is necessary for the company to see a return on the investment. More than ever, the charging infrastructure is a key success factor for the electric vehicle. White Paper | 13 Management of electric vehicle fleet charging White Paper | 14 Management of electric vehicle fleet charging Glossary • Fleet manager: person managing the company vehicle fleet • Automatic vehicle fleet charging management: technical measure controlling electric vehicle charging via the charging stations (based on criteria such as tariff bands, available power, vehicle priority and reservation slots booked by the drivers). • Station or hub: technical device to which the vehicle is connected to charge it. • Cable: technical device used to connect the vehicle to the station. • Key cupboard: technical device delivering the keys of the vehicle booked by the driver when he comes to get it • Server: technical device which recovers, stores and transfers data • Web service: utility which processes and formats data from the server for a user • Reservation manager: technical measure allowing the driver to book a vehicle via an interface • Station manager: technical measure managing the power supply to the stations and energy management reGulatorY and P ol icY does your community need to update local zoning codes to allow or require charging stations for residential, multi- family, businesses, parking lots and parking garages? have you reviewed sample language available from local governments in other states to inform amendments to local ordinances? do you offer certification or participate in regional certification efforts for contractors to be approved electric vehicle supply equipment (evse) installers? could you offer local incentives for residents or businesses to purchase Pevs or install evse? has your public safety department looked into training opportunities for firefighters and first responders for emergencies with Pevs and evse equipment? have you explored opportunities to bring Pev-related jobs and industry to the local area? inFrastructure have you developed a list of priority sites for public charging? have you researched and/or selected a preferred vendor(s) for charging stations? have you explored the options for public charging stations? have you asked for an engineering analysis of any necessary upgrades to electrical capacity, conduit, or concrete work for preferred sites? have you assessed your need for wireless networking, soft- ware and billing system processes? are you able to meet the required engineering and planning approvals needed? have you identified a local electrical contractor? has your contractor installed other charging stations in your city or town? have you addressed american with disabilities act (ada) compliance issues and provided evse in handicap- accessible parking spaces, if required? have you considered if or how you might price the use of charging stations? Who will maintain the public charging stations? have you consulted with legal counsel to determine if there are any potential liability issues? Fleets are you familiar with your company’s procurement policies? Government agencies have many opportunities to participate in assisting the roll-out of Pevs in their local area. the cFcc is leading the organized expansion of Pevs to help improve the region’s air quality and energy efficiency. ccFc’s leadership will also reduce governmental costs by eliminating redundancy of efforts. Based on work by national leaders with municipalities at the forefront of electric transportation, this guide sheet provides a summary of considerations as you move forward. Guide sheet for Government/ Public sector ccFc ’s Moving ahead with Plug-in electric ve- hicles (Pev ) the centralina clean Fuels coalition (ccFc) is a u.s. dept. of energy clean cities program. do you know the current Pev makes and models available in your area? has your fleet manager reserved cars through local dealerships or the manufacturers’ websites for purchase or lease? can you wait for vehicles to become available? have you considered the cost to replace cars and whether it makes sense to lease vs purchase? have you calculated the costs of electricity versus your current gasoline costs? have you obtained tax advice regarding rebate and tax-related opportunities? do you understand the various original equipment manufacturer (oeM) warranties offered? have you considered battery life—and are you aware of recycling options? have you calculated and budgeted for the cost of installing higher capacity esve in government vehicle lots? do you have resources to train staff on vehicle use, charging, maintenance and safety? Pu Blic/Private ou treach can you leverage existing communications outlets to communicate regional Pev readiness efforts to citizenry and business community/private sector? Will you upload the locations of public charging stations in your area to the national database and/or provide a map for your community? are you able to keep your web information current? can you assess and promote Pev jobs and economic opportunities through city marketing or economic development offices? learn More there is a learning curve to purchasing and operating a Pev but you’re not alone—we’re here to help. links to useful websites Go4Pev.org www.duke-energy.com/plugin learn more about the technology and resources at www. advancedenergy.org/transportation www.Goelectricdrive.com www.afdc.energy.gov/afdc/locator/stations/ national database to add public charging stations. www.evsafetytraining.org continuedGuide sheet for Government/ Public sector d on’t F or G et to sign up for ccFc Pev e-newsletter at Go4Pev.orG/hoMe EV Infrastructure Installation Guide 27 5. EV CHARGING AT FLEET FACILITIES Government, utility, and private fleets are currently the largest market for EVs. Federal and Cali- fornia clean air regulations specifically target fleets in their attempts to increase the number of clean air vehicles. PG&E has been a leader in introducing both EVs and natural gas vehicles into their fleet and can provide considerable assistance to other organizations attempting to meet clean air mandates. The process of establishing EV charging infrastructure in fleet facilities is more complicated than in residential settings but many of the underlying issues are the same. This chapter outlines issues that are specific to fleet applications. A. Site Planning Many siting issues influence the successful planning of a charging facility: 1. Number of EVs and Chargers Planners must be realistic when determining the number of EVs a fleet will include, because that number will determine each facility’s charging requirements. Estimates must include the number of fleet vehicles to be added over the next three to five years, with special attention to meeting upcoming state and federal AFV mandates. The facility operator should also consider planned flexibility that allows the site to grow with developing technologies or changes in charging re- quirements. Planners should seriously consider installing extra circuits and additional electrical capacity during initial construction, when costs are minimal. Fleet managers should analyze what the fleet’s charging schedule will be by developing a charg- ing curve for each vehicle in the fleet (see next page). The curve matches the time of day a vehi- cle is recharged with the amount of energy used. After developing a curve for each vehicle, they can be aggregated to get a facility-wide fueling curve. This calculation will determine the fre- quency of charging and the energy required to service the entire facility. It will also facilitate equipment scheduling by helping determine the amount of time needed to recharge each vehicle. Based on the information taken from the charging curve, a facility manager can plan: charging needs (number of chargers), facility energy needs, and the necessary mix of Level 2 and Level 3 charging. The vehicle manufacturer and EVSE supplier can provide fleet managers with sample charging time and electricity consumption figures in order to develop a charging curve. Several factors must be considered when deciding between Level 2 or Level 3 charging. Because of the length of time necessary to complete Level 2 charging, a facility will most likely need one charger per vehicle, as charging will take place overnight. This scenario may require additional land, island construction, cabling, and transformers—and will require the installation of appro- priate EVSE. These factors can increase capital costs significantly. Installing Level 3 charging will raise costs for cabling, transformers, and chargers, but possibly lower land and construction costs. EV Infrastructure Installation Guide 28 How a fleet uses its vehicles will determine the appropriate charging method. Vehicles requiring expanded range may require a fast mid-day charge, requiring rapid Level 3 charging. However, Level 3 charging will raise equipment and electricity costs. In addition, some EV manufacturers will void the vehicle’s warranty if the owner uses Level 3 charging. Each facility manager must carefully assess their fleet use and weigh the cost differences before deciding on using one charging level or a combination of both. As mentioned earlier in this section, the following table shows a sample aggregated charging curve for a fleet facility. Time Number of vehi- cles Type of vehicle Electricity dispensed (kWh) Charge level Total charge time per vehi- cle* 1:00 2:00 3:00 4:00 5:00 6:00 2 Shuttle buses 200 3 1 hr. each 7:00 8:00 9:00 10:00 11:00 12:00 2 Pass. cars 50 3 15 min. each 13:00 14:00 15:00 16:00 17:00 18:00 19:00 20:00 4 Pickups 100 2 4.2 hrs. each 21:00 22:00 23:00 2 Pass. cars 50 4.2 hrs each 24:00 Total 400 kWh 27.7 hrs. * Charge time is determined by vehicle charging algorithm. 2. Convenience Locate the charging station so that it accommodates other activities within the fleet facility. It is advisable to locate the station in a low-traffic area of the facility, because EVs may be required to remain parked for several hours at a time and therefore could block the movement of other fleet vehicles. EV Infrastructure Installation Guide 29 3. Cable Management Cords and cables associated with charging equipment should not cross sidewalks or pedestrian traffic patterns. 4. Ventilation Needs As discussed in Chapter 2, most of today’s advanced batteries do not require ventilation during charging. However, some earlier battery types do produce and emit gases during charging as a result of electrolysis. Due to the concerns related to these older battery types, the facility man- ager should ensure that adequate ventilation is in place when older battery types that do emit gases are included in their fleet. The cost of ventilation equipment, including fans, ducts, and air handlers, ranges from $400 for a 320 cfm centrifugal roof exhauster to $2,550 for a 1000 cfm industrial exhauster. Equipment should be based on the specific enclosure and the number of chargers installed. 5. Battery Operating and Charging Temperature Limits Some EV batteries have operating and charging temperature limits, so under some circumstances (such as cold climate conditions) it may be necessary to site the EVSE in an enclosed area. 6. Standing Water and Irrigation Even though all EVSE have been designed for safe operation in wet areas, user comfort will be increased by not placing equipment in locations where water pools or within the spraying area of irrigation systems. 7. Curbs, Wheel Stops, and Setbacks To avoid vehicles from inadvertently driving into the EVSE, provide curbs, wheel stops, and set- backs. Consider user access and mobility issues when installing this equipment (see section 10 in this chapter – Disabled Access). 8. Vandalism Planners should site EVSE to avoid the risks of vandalism or tampering. Consider including motion detectors, security lighting, tamper alarms, locked enclosures, and fences. The level of protection required will depend on the location of the EVSE, whether access is public or private, and the overall security requirements of the facility. 9. Signs Fleet operators may want signage to designate EV-only parking spaces. These should be posi- tioned high enough to be seen over parked vehicles. 10. Disabled Access ADA Compliance: Connector and receptacle heights, special curb cutouts, and disabled parking access are some of the measures that may be necessary to make a charging station fully accessi- ble for the disabled. Each operator must assess their compliance with the federal Americans with Disabilities Act, as well as state and company policies regarding disabled access. EV Infrastructure Installation Guide 30 The State of California’s Division of the State Architect has issued “Interim Disabled Access Guidelines for Electric Vehicle Charging Stations” (Policy #97-03). EV charging stations are re- quired to be accessible because they offer a service to the general public. When EV charging is coupled with regular parking, the EV charging is considered the primary service. The following table should be used in determining the required number of accessible chargers: Number of Chargers Pro- vided at a Site Number of Accessible Charger Spaces Required 1 to 25 1 26 to 50 2 51 to 75 3 76 to 100 4 A 9-foot wide space by 18-foot deep space is required. An access aisle of 5 feet on the passenger side is also required. One in every eight accessible chargers, but not less than one, should be van accessible with an 8-foot access aisle. Accessible charging spaces are not reserved exclusively for people with disabilities. It is also recommended that accessible spaces be located in close proximity to the facility they serve. For new construction, an accessible path from the charger to the other services provided at the site is required. B. Checklist for Fleet Facility EVSE Siting Facility planners should answer the following facility planning questions before proceeding fur- ther: What level of charging will be used? What are the charger requirements? Is the existing electricity supply adequate for fleet needs? What is the location of the electrical service relative to the charging equipment siting? What will be the impact of electricity rates on choosing alternative approaches to fleet EV charging? What are the cost trade-offs between charging levels and equipment locations? Have I addressed all of the relevant federal, state, and local code requirements? C. Engineering and Construction Many pieces of equipment are unique to EV charging facilities, and fleet managers should be careful to select contractors familiar with their specifications. In addition to the standard civil engineering work required to construct any fueling facility, EV facilities will require considerably more electrical service and electrical equipment installation. A primary consideration for the site designer and the facility manager is the condition and loca- tion of the existing electric utility equipment. These factors will govern the number and size of EV Infrastructure Installation Guide 31 transformers, necessary trenching or overhead cabling, conduits, amount of cabling, and associ- ated installation costs. The key component in the interface between the existing electrical system and the EVSE is the transformer. To provide adequate power for Level 2 charging equipment, existing electrical service must be stepped down to a level that can work with Level 2 charging equipment: 208– 240 volts. If not already available at the site, it will be necessary to install an isolation trans- former capable of stepping electricity to 208–240 volts for Level 2 charging, or up to 480 volts for Level 3 charging. Isolation transformers can cost between $7,200 to $8,500. D. Charging Equipment As discussed in Chapter 2, charging equipment decisions depend on the EV charging designa- tion: inductive or conductive, Level 2 or Level 3. Until the market determines which charging technology dominates, it is likely that both inductive and conductive charging will develop in parallel. Until a charger and connector standard evolves, some fleets may select a mix of induc- tive and conductive chargers, depending on what their fleet EVs require. Presently, there are several different manufacturers supplying different types of connectors for conductive charging equipment. Facility managers should ascertain that the connector is com- patible with the receptacle on the vehicle. Vehicle manufacturers can supply the proper connec- tor specifications for their vehicles. E. Fleet Recharge Management Systems Another component of a charging facility will be its Fleet Recharge Management System (FRMS). An FRMS is an integrated, computerized charging system that is designed to eliminate the costly process of managing electric vehicle charging for fleet applications by automatically sequencing multiple chargers. These systems are designed to accomplish the following goals: Automate recharging of fleet vehicles, thereby reducing the need for human intervention in the process Eliminate redundant charging infrastructure at charging locations where more than one vehi- cle will be charged Reduce overall fleet management labor costs Reduce electric charging costs through load management Reduce electric utility infrastructure needs, thereby lowering the cost to serve the load Allow fleet operators to choose all charging parameters The key to an FRMS is its ability to manage charger sequencing. This functionality will deter- mine the ultimate value of any system that is developed. It is likely that any successful system will be computer-controlled and be able to communicate with the local utility to take advantage of time-of-use rates or real-time pricing. By managing the electrical load in this manner, the FRMS will use electricity economically and will optimize fleet energy use. EV Infrastructure Installation Guide 32 One FRMS is currently under development by Southern California Edison and has been demon- strated using existing hardware. The goal of this pilot is to study the feasibility of the system, determine its strengths and weaknesses, determine fleet operator needs, and transform those needs into algorithms that can be improved in the future. This knowledge will be used to de- velop hardware that can be easily mass-produced to lower overall system costs. The key component of this FRMS is the charge controller that automates the charging process. Through a PC-compatible computer, the controller distributes enough charge to maintain low overall peak electricity costs, while keeping connected vehicles in a state of full charge. It acts by interfacing with individual charging meters to perform the following tasks: Report on the required charge of each vehicle Determine the initial charge level of each plugged-in vehicle Determine the energy flow through the system Receive synchronization commands from the local utility through a communications device Display historical and real-time information Provide diagnostics Other utilities are investigating different load management devices. The Electric Vehicle Re- search Network has sponsored a study of charge management systems in conjunction with Nor- vik. This system is a charge sequencer for fast chargers and does not have some of the enhanced features mentioned above. The full costs of FRMS have yet to be determined but could be minimized by the use of existing computers, meters, communication devices, and kiosks. It is estimated that costs for a complete FRMS will range from $4,000 to $10,000 depending on the number and level of chargers. For more information on the SCE system, please contact Sam Katagi at (626-302-9515). F. Metering and Billing Systems While metering/billing systems are most often associated with public refueling systems, fleets may also want to investigate their use. Along with the FRMS, these systems can be very helpful in matching electricity consumption to individual vehicles. A typical system could incorporate advanced billing capabilities to help generate detailed monthly statements, including tracking by vehicle identification number. This system would allow fleet managers to track EV use, charging times, and associated energy costs. Several system options are available to fleet operators and are designed to accommodate individual access and reporting policies, including direct utility billing or point-of-sale billing. Metering and billing system prices vary, depending on which features are included. Prices range from $800 for a debit card system to $2,700 for a cashless voucher system to $14,000 for a TECH-21 proprietary card system. Fleet managers should assess their needs in this area to choose the appropriate system. Because the current billing systems are most compatible with gasoline and diesel fuels, charging equipment manufacturers would have to modify their systems for EV use. Recently, EVSE manufacturers have begun to make their equipment compatible with existing metering and billing systems. EV Infrastructure Installation Guide 33 G. Electrical Service Generally, one charger will be required for each EV for overnight recharge (Level 2). The typical electrical demand for original equipment manufacturer vehicles using 240V single-phase service is 7 kW while charging for buses and fast chargers (using 480V three-phase service) can have demand levels of 50 kW or more. Actual kW demand is determined by the individual charging algorithm required by the vehicle. PG&E can help the fleet manager determine electricity re- quirements and compare them to existing service. If the feeder line must be upgraded and new transformers added, the organization should add sufficient capacity to meet the site's EV charging needs for several years. If the fleet manager plans to install Level 3 fast chargers, the electrical service requirements should also meet this load. When evaluating electrical service, managers should examine the following issues: Service Level. Determine the location, capacity and types of service panels and on-site trans- formers. Distances Between Equipment. Determine the distance between service entrance, trans- formers, panels, subpanels, and parking locations. Identification of Potential Hazards. Ensure that EV charging spaces are not located near potentially hazardous sites such as gasoline fueling areas. When determining electrical needs for recharging, the fleet manager should contact PG&E to determine if existing feeder lines and equipment can provide the service, or if they must be up- graded. Other factors to be considered include the costs of running three-phase power to the site and stepping it down to single phase, or using high-voltage single phase and a step-down transformer to the appropriate voltage. Again, local utilities will be able to assist facility planners in deter- mining what service changes or upgrades will be necessary. H. Electric Rates The additional electrical demand for each EV charging during peak-demand periods may move a customer into a higher rate category. Charging multiple EVs may also trigger a surcharge for the reactive component of energy consumed. Fleet managers should discuss the impact of EV charging on rates with a PG&E representative. During the planning process, it is also important to discuss potential loads so that PG&E can assess their impact on PG&E’s overall system. Fleet charging may have some effect on peak power demand, especially when Level 3 charging is used. The integration of an FRMS at the fleet site can manage and minimize demand by sched- uling charging at off-peak times whenever possible. I. Site Installation Plan Many municipalities require EV fleets to develop and submit an installation plan for engineering review and approval. Fleet managers may want to hire an electrical contractor for this task. A site plan typically describes: EV Infrastructure Installation Guide 34 Location of the main electrical panel, branch circuits, and conduits Location of hazardous materials Location of charging stations Lighting Traffic flow Ventilation (if necessary) Description and locations of signs Curbing, wheel stops, cutouts, setbacks, and bumper guards Parking spaces, striping, driveways, and walkways Landscaping J. Building Permits Building and electrical permits are required for EVSE installations (see Chapter 3). Some utilities will not energize new charging circuits until they have passed inspection and the city or county notifies the utility. The cost of the permit and installation varies by municipality and depends on the scale of the upgrade. K. Costs The cost of installing fleet charging facilities can vary dramatically depending on the following factors: The number of circuits and chargers installed Whether the facility is indoors or outdoors The need to upgrade electrical service to the charging facility Whether ventilation is or is not required Whether Level 3 fast charge equipment is used or not Availability of discounts, tax deductions, and rebates from air districts and others. In general, the cost to its fleet customers of installing EVSE range from $500 per vehicle per site to more than $5,000 per vehicle per site. The average cost per vehicle is $2,000. For reference only, the following table lists some sample costs for specific components. Actual costs will vary and all costs may not apply to all installations. The costs quoted are applicable for fleet, public access, and multifamily charging installations. EV Infrastructure Installation Guide 35 Sample EV Charging Installation Costs for Public, Fleet, or Multifamily Buildings (all esti- mates are for installed costs) Item Cost Power Distribution Sub-Panel -200A, 120/240 VAC single phase; three wires with main circuit breaker; six 40A/2P branch circuit breakers $1,435 * Transformer 50 kVA, 480/277 VAC primary, 120/240 VAC; 3 wires secondary; dry type NEMA 1 enclosure If power comes directly from utility distribution system: transformer pad; NEMA 3R, 200A, 120/240 VAC; 3 wires combination meter/main service and panelboard; ground rod (PG&E can furnish and install the transformer.) $ 3,975 * $ 5,300 Cables/Conduits a) 40A branch circuit - Above ground installation - Underground installation b) 200A feeder circuit - Above ground installation - Underground installation $3.85/linear ft ** $6.85/linear ft ** $13.25/linear ft ** $21.00/linear ft ** Lighting 250 watt, metal halide, parking lot lighting a) Wall or ceiling mounting b) On 16 ft galvanized steel pole, concrete base $640 each * $2,750 each * Concrete Island In-place concrete island 6 in thick reinforced $7.20/ft2 ** Concrete Steel Pipe (Transformer or EVSE protection) Concrete fill steel pipe, 8 ft high, set 4 ft in ground, rounded top, painted $155 each * Concrete Bumper (EVSE protection) 4 ft long precast concrete bumper $88 each * Paving a) Demolition b) Asphalt paving composite $1.95/ft2 ** $33.00/ft2 ** Signs 24 in x 24 in reflective signs; 2 in galvanized steel pole $200 each * Landscaping Soil preparation, irrigation system, sod (excludes trees and shrubs) $6.10/ft2 ** * Sample costs only. Actual cost may differ significantly depending on location, site requirements, installation, and equipment specification. ** Sample costs provided by Ocampo Esta Corporation. Actual cost may differ significantly. EV Infrastructure Installation Guide 36 L. Checklist for Vehicle Fleet Charging Estimate 3–5 year EV purchase plans. Determine recharging locations. Estimate the electrical load at those locations. Determine whether to use Level 2 or 3 charging and type of charging to be used: in- ductive and/or conductive Obtain charger requirements from vehicle and charger suppliers Develop charging curves Determine the appropriate number of chargers 4. Contact vehicle and charger suppliers. Confirm charging needs and types Identify any special ventilation requirements Identify any other special considerations for the specific equipment 5. Contact PG&E. Assess existing electricity supply Determine necessary electrical service upgrades Review metering requirements Determine the impacts of rates on choosing alternative charging methods Determine if any other special requirements exist 6. Develop a detailed facility site plan. Develop and review wiring diagrams Develop and review ventilation diagrams Determine if there are hazardous material locations at site Review traffic, pedestrian flow, parking requirements, and ADA compliance issues Determine additional retrofit needs, including landscaping 7. Contact pertinent permitting agencies. Identify special local fire, construction, environmental, or building requirements Obtain all applications Determine additional permitting costs Determine site plan requirements 8. Hire the prime contractor and verify contractor subcontractor credentials. Obtain all pertinent building and use permits. EV Infrastructure Installation Guide 37 Perform any necessary electrical upgrades, install EVSE, and complete all site prepara- tions. Have the site inspected by pertinent building, fire, environmental, and electrical authori- ties. Comply with any change order, if necessary Notify PG&E that site has passed all inspections 12. Begin charging operations. EV Infrastructure Installation Guide 38 The following flowchart illustrates the process of installing EVSE infrastructure at a fleet facil- ity: 2. Determine EVSE Locations 3. Estimate Electrical Load at Locations 4. Contact PG&E 5. Contact EV/EVSE Suppliers 6. Contact Building Permit Office 7. Hire Contractor 1. Estimate 3-5 Year EV Purchase Plans 8. Develop Site Plan 9. Obtain Building Permit 10. Install EVSE and Prepare Site 11. Building Department Inspections 12. Charge Vehicles • Conductive and/or inductive? • Ventilation required? • Special requirements? City notifies PG&E that EVSE passed inspection • Local requirements? • Application form •Cost? • Site plan requirements PG&E installs EVSE metering equipment • Obtain charger requirements from EV/charger suppliers • Level 2 and/or Level 3? • Number of chargers • Is electricity supply adequate? • Metering? • Impact on rates? • Special requirements? • Electric service upgrading,if any • Wiring diagrams • Ventilation diagrams if required • Hazardous material sites • Traffic and pedestrian flow and parking • Landscaping • Compliance with special requirements Comply with change orders Appendix F. Demand Control & Smart Grid Information Home >Charging Share BMW charging Charging Locator Chevrolet Volt Chevy Volt CODA Sedan Events Fit EV Fleets Ford Focus Electric Grid Electricity hands free Honda Incentives for EV Buyers Mitsubishi i mobile Nissan LEAF pluginday Prius Range RAV4 roadmap Safety Showroom Tesla Tesla Model S Tesla Roadster Toyota Transit Connect Electric Vehicles Connect CHARGING Charging Overview Charging Station Locator Home Charging Workplace Charging Public/Commercial Charging Fleet Charging Utility Resources Charging Safety and Standards Charging Station Showroom Find an EV Charger Utility Resources Utilities Role and Resources Utilities are working hard to prepare for the adoption of PEVs among their customers. If drivers charge their PEVs at night, when demand is low and the utilities have adequate generating capacity, utilities will increase their electricity sales and make more efficient use of their existing power plants. However, if most drivers recharge their cars during the day, when demand is twice as high, utilities could have to generate or purchase extra electricity when it is most costly. In some states, utilities have already begun investing in technology that will leverage the benefits of plug-in vehicles: "smart" utility meters that will allow both utilities and customers to track power use by purpose and time of day. The meters will permit utilities to move toward variable rates for electricity, charging higher rates during peak demand in the daytime while offering less expensive rates at night. The plan is to encourage PEV owners to charge their cars at night or off peak times. Smart Grid Utilities are devising energy efficiency improvement strategies through the development of PEV and utility communications technologies and standards to facilitate customer incentive programs to control and reduce the anticipated impact to the nation’s grid. These efforts will help avoid the large capital investment for more generation plants. The Administration has provided the legislation and the funding to catalyze the development of the strategies, technologies, and standards for a more energy efficient electric grid. The Department of Energy (DOE) has chartered the National Institute of Standards and Technology (NIST) to coordinate the implementation of the Smart Grid Roadmap and Architecture. The NIST Smart Grid Interoperability Collaboration is addressing the determination of requirements, specifications, and standards for more effective load to grid integrated communications and control systems. The electric transportation smart grid interface standards, including PEV load measurements, monitoring, communications and control are being addressed as part of this effort. Smart grid technologies and standards are still in the development phase with implementation planned over the next several years. Charging Costs The various rate options for charging your electric vehicle depend on the availability of rates at each individual utility. Some utilities will not offer any additional rate options. In this situation, the customer will simply add the vehicle usage to the existing rate schedule as he or she would add any end use device to their home. The pricing could be as simple as a flat price per kWh or GET STARTED DRIVE ELECTRIC! ELECTRIC CARS CHARGING INCENTIVES FAQ & GLOSSARY NEWS & EVENTS ABOUT RESOURCES Search Page 1 of 2Utility Resources 4/11/2013http://www.goelectricdrive.com/index.php/utility-resources ©Copyright 2013 GoElectricD rive.com powered by EDTA . All Rights ReservedPrivacy Policy Term s of Use Membership Site Map Log On it could have different prices depending on the seasons. Some seasonal pricing includes declining rate blocks (the more electricity you use the cheaper it gets), which would imply that the vehicle is charging on the cheapest portion of the rate; however, the schedule could also include inclining blocks (the more you use, the more expensive it gets). Additional Questions about Utility Resources What are the first steps for letting my utility know I am interested in charging my PEV? You can contact your utility to get information on discount rates, demand response programs, meter options, and an electricity cost assessment for the added PEV load. Utilities are interested in knowing where charging stations are being installed to help them assess the load impact on their local grid distribution system. Can the grid handle an influx of PEVs? Yes. Numerous studies have shown that the grid can support a large number of PEVs. Total capacity is not an issue. Rather, utilities are working to forecast and manage their local distribution system to accommodate the load requirements in neighborhoods and cities where there may be high concentrations of PEVs. back to top Page 2 of 2Utility Resources 4/11/2013http://www.goelectricdrive.com/index.php/utility-resources Contact Us > Client Login > GridPoint Energy Management System The GridPoint Energy Management System (EMS) is a complete hardware, software, and services solution that delivers the visibility, analysis, and control capabilities to manage your facility’s energy endpoints, from HVAC and lighting, to refrigerators and more. With the GridPoint EMS, information captured about energy and facility environmental conditions provides the insights and recommendations to fine-tune your sites to optimize energy efficiency and site operations. GridPoint Energy Management Systems have been deployed at more than 11,000 sites to date, and can average 10-20% energy savings per site per month, with a corresponding 18-24 month return on investment per site. Questions? Our energy solution experts are here to help.Ask now Control GridPoint Energy Manager System Components EMS Overview Hardware Software Services Case Studies Solutions Industries About Us Page 1 of 2EMS Overview | GridPoint 4/11/2013http://www.gridpoint.com/ems-overview/ems-overview Quickly evaluate and act on energy endpoint performance.Establish setpoints and schedules across a diverse footprint. Gain detailed visibility into site operations and energy usage with a variety of reports and alarms presented through an intuitive, web-based user interface. Monitoring with Submetering Optimize energy savings activities with granular, equipment-level monitoring of endpoints ranging from lighting and HVAC, to gas and water meters. Energy Advisory Services Make the most out of your energy data with proactive tracking, management and evaluation of critical energy issues by our team of data analysts. Generate immediate and sustainable savings opportunities Intelligent controls, real-time submetering, and enhanced monitoring devices offer continuous insight into critical equipment and environmental conditions, ensuring predictable energy spend, as well as immediate and long-term cost savings. Boost staff productivity and efficiency Seamlessly control temperature and lighting schedules across thousands of sites from a single, integrated dashboard. Comprehensively monitor energy activity and prioritize needs, saving valuable time. Ensure equipment is functioning properly and avoid costly repairs Equipment–level visibility allows you to understand individual unit performance, identify costly issues, and quickly perform preventative maintenance. Integrate systems with ease Whether you are just getting started or have an EMS in place, the GridPoint EMS is designed to work with existing control and monitoring infrastructures, eliminating the need for a costly rip and replace process. Questions? Our energy solution experts are here to help.Ask now Search Home |Sitemap |Privacy Policy |Terms of Use |Contact Us Solutions FOR ENTERPRISES Energy Management Systems Solar Energy Systems FOR UTILITIES Enterprise (C&I) Energy Efficiency Customer Engagement Platform Load and Storage Management Industries Retail Restaurant Grocery Convenience Store Government Other About Us Corporate Overview News & Events Management Team Board of Directors Investors Careers © 2013 GridPoint, Inc. All rights reserved. GridPoint is a registered trademark of GridPoint, Inc. Benefits Page 2 of 2EMS Overview | GridPoint 4/11/2013http://www.gridpoint.com/ems-overview/ems-overview Customer Support 1-484-690-3820 T ech Support 1-484-690-3822 HOME MEET BERT APPLICATIONS SUPPORT SAVING ENERGY ABOUT Story of Mass Control Why Bert?Measurement IT Requirements Specifications Meet Bert® Bert® can help you measure, analyze and control plug load throughout your facility. Using your existing Wi-Fi network and Bert’s unique plug load management system you can finally gain control of the hundreds of plug-based loads across your facility. The Bert® Plug Load Management System The Bert® plug load management system consists of the Bertbrain 1000M control software, your Wi-Fi network, and a virtually unlimited number of Berts®. Each Bert® contains a small microprocessor that measures instantaneous energy consumption and connects as a device on your network. Connect Bert® to water coolers, copiers, TVs, vending machines… just about anything that is plugged into a 15 AMP/ 120 Volt outlet. Each Bert® is named, and can be scheduled individually or in groups. Read About Bert® Click on the link below to read a white paper describing how the Bert® plug load management system can help control energy costs in your facility. Meet Bert ©2013 Green Power Technologies, LLC. Bert is a registered trademark of Green Power Technologies. Contact Bert Page 1 of 1Meet Bert -Control plug based load using WiFi 4/18/2013http://www.bertbrain.com/about Appendix G. Samples – DOE Vehicle Cost Calculator Vehicle Cost Calculator This tool uses basic information about your driving habits to calculate total cost of ownership and emissions for makes and models of most vehicles, including alternative fuel and advanced technology vehicles. Also see the cost calculator widgets. ASSUMPTIONS Choose vehicles to compare EDIT Clear all 2013 Make ModelModel Vehicle Price Fuel Economy (City/Hwy) Fuel Type 2013 Chevrolet Volt 4cyl 1.4L Automatic (variable gear ratios) Plug-in Hybrid $ Tax credit? 35/40 mpg 33/36 kWh/100m Plug-in Hybrid 2013 Toyota Prius Plug-in Hybrid 4cyl 1.8L Automatic (variable gear ratios) Plug-in Hybrid $ Tax credit? 51/49 mpg 26/33 kWh/100m Plug-in Hybrid 2013 Ford C-MAX PHEV FWD 4cyl 2.0L Automatic (variable gear ratios) Plug-in Hybrid $ Tax credit? 44/41 mpg 31/37 kWh/100m Plug-in Hybrid 2013 Mitsubishi i-MiEV Automatic (A1) EV $ Tax credit? 27/34 kWh/100m Electric 2013 CODA Automotive CODA Automatic (A1) EV $ Tax credit? 44/50 kWh/100m Electric 2013 Ford Fusion AWD 4cyl 2.0L Automatic (S6) Gasoline $ 22/31 mpg Gasoline 2013 Toyota Highlander 4WD 6cyl 3.5L Automatic (S5) Gasoline $ 17/22 mpg Gasoline 2013 Chevrolet Cruze 4cyl 1.8L Automatic (S6) Gasoline $ 22/35 mpg Gasoline Gasoline $ /gal Tell us how you use your car EDIT Normal Daily Use Average daily driving distance miles Days per week Weeks per year 49 Percent highway Annual Driving Distance City Distance Highway Distance 9800 miles 9800 miles 0 miles Other Trips Annual mileage miles Percent highway Electricity Use Enter your ZIP code so we can find the electricity price and calculate the emissions from generating electricity in your area. ZIP Code How often do you plug in your vehicle during normal daily use? Twice a day Daily Every other day Create Custom Vehicle Clear all Fuel Prices U.S. Department of Energy -Energy Efficiency and Renewable Energy Alternative Fuels Data Center Page 1 of 2Alternative Fuels Data Center: Vehicle Cost Calculator 4/24/2013http://www.afdc.energy.gov/calc/ Results Vehicle Annual Fuel Use Annual Electricity Use Annual Fuel/Elec Cost Annual Operating Cost Cost Per Mile Annual Emissions (lbs CO2) 2013 Chevrolet Volt Plug-in Hybrid 14 gal 3,072 kWh $408 $2,551 $0.26 347 2013 Toyota Prius Plug-in Hybrid Plug-in Hybrid 139 gal 701 kWh $774 $2,917 $0.30 3,449 2013 Ford C-MAX PHEV FWD Plug-in Hybrid 106 gal 1,595 kWh $704 $2,848 $0.29 2,619 2013 Mitsubishi i-MiEV EV 0 gal 2,646 kWh $291 $2,309 $0.24 0 2013 CODA Automotive CODA EV 0 gal 4,312 kWh $474 $2,492 $0.25 0 2013 Ford Fusion AWD Gasoline 445 gal 0 kWh $2,227 $4,371 $0.45 11,029 2013 Toyota Highlander 4WD Gasoline 576 gal 0 kWh $2,882 $5,026 $0.51 14,273 2013 Chevrolet Cruze Gasoline 445 gal 0 kWh $2,227 $4,371 $0.45 11,029 GET RESULTS Cumulative Cost of Ownership by Year (Dollars) This graph shows the cumulative cost of ownership by year for each vehicle, including fuel, tires, maintenance, registration, license, insurance, and loan payment. The tool assumes a five-year loan with a 10% down payment. Year one on the graph represents the 10 percent down payment plus the first year's total operating costs. For more information on this graph and other calculations, see the assumptions page. Disclaimer: The U.S. Department of Energy (DOE) and the National Renewable Energy Laboratory (NREL) do not endorse any companies or products described on the Vehicle Cost Calculator. Vehicle prices and specifications change frequently. Not all data have been verified by DOE or NREL, which manages the site. Consult a dealer or vehicle manufacturer before making purchasing decisions. The AFDC is a resource of the U.S. Department of Energy's Clean Cities program. Contacts | Web Site Policies | U.S. Department of Energy | USA.gov Content Last Updated: 04/24/2013 Page 2 of 2Alternative Fuels Data Center: Vehicle Cost Calculator 4/24/2013http://www.afdc.energy.gov/calc/ Vehicle Cost Calculator This tool uses basic information about your driving habits to calculate total cost of ownership and emissions for makes and models of most vehicles, including alternative fuel and advanced technology vehicles. Also see the cost calculator widgets. ASSUMPTIONS Choose vehicles to compare EDIT Clear all 2013 Make ModelModel Vehicle Price Fuel Economy (City/Hwy) Fuel Type 2013 Ford F150 Pickup 4WD FFV 6cyl 3.7L Automatic 6-spd FFV $ Tax credit? 16/21 mpg 11/15 mpg E85 Flex Fuel 2013 Ford Expedition 4WD FFV 8cyl 5.4L Automatic 6-spd FFV $ Tax credit? 13/18 mpg 9/13 mpg E85 Flex Fuel 2013 Ford Explorer AWD FFV 6cyl 3.5L Automatic (S6) FFV $ Tax credit? 17/23 mpg 12/17 mpg E85 Flex Fuel 2013 Chevrolet Suburban 1500 4WD 8cyl 5.3L Automatic 6-spd FFV $ Tax credit? 15/21 mpg 11/16 mpg E85 Flex Fuel 2013 Toyota Tundra 4WD FFV 8cyl 5.7L Automatic (S6) FFV $ Tax credit? 13/18 mpg 9/12 mpg E85 Flex Fuel Gasoline $ /gal E85 $ /gal Tell us how you use your car EDIT Normal Daily Use Average daily driving distance miles Days per week Weeks per year 49 Percent highway Annual Driving Distance City Distance Highway Distance 9800 miles 9800 miles 0 miles Other Trips Annual mileage miles Percent highway E85 Ethanol Use For flex fuel vehicles that run on either E85 or gasoline, how often do you anticipate using E85? Percent E85 use % Results Vehicle Annual Fuel Use Annual Electricity Use Annual Fuel/Elec Cost Annual Operating Cost Cost Per Mile Annual Emissions (lbs CO2) 2013 Ford F150 Pickup 4WD FFV 613 gal 0 kWh $3,063 $5,206 $0.53 15,166 2013 Ford Expedition 4WD FFV 754 gal 0 kWh $3,769 $5,912 $0.60 18,665 2013 Ford Explorer AWD FFV 576 gal 0 kWh $2,882 $5,026 $0.51 14,273 2013 Chevrolet Suburban 1500 4WD FFV 653 gal 0 kWh $3,267 $5,410 $0.55 16,177 2013 Toyota Tundra 4WD FFV 754 gal 0 kWh $3,769 $5,912 $0.60 18,665 Create Custom Vehicle Clear all Fuel Prices GET RESULTS U.S. Department of Energy -Energy Efficiency and Renewable Energy Alternative Fuels Data Center Page 1 of 2Alternative Fuels Data Center: Vehicle Cost Calculator 4/24/2013http://www.afdc.energy.gov/calc/ Cumulative Cost of Ownership by Year (Dollars) This graph shows the cumulative cost of ownership by year for each vehicle, including fuel, tires, maintenance, registration, license, insurance, and loan payment. The tool assumes a five-year loan with a 10% down payment. Year one on the graph represents the 10 percent down payment plus the first year's total operating costs. For more information on this graph and other calculations, see the assumptions page. Disclaimer: The U.S. Department of Energy (DOE) and the National Renewable Energy Laboratory (NREL) do not endorse any companies or products described on the Vehicle Cost Calculator. Vehicle prices and specifications change frequently. Not all data have been verified by DOE or NREL, which manages the site. Consult a dealer or vehicle manufacturer before making purchasing decisions. The AFDC is a resource of the U.S. Department of Energy's Clean Cities program. Contacts | Web Site Policies | U.S. Department of Energy | USA.gov Content Last Updated: 04/24/2013 Page 2 of 2Alternative Fuels Data Center: Vehicle Cost Calculator 4/24/2013http://www.afdc.energy.gov/calc/