HomeMy WebLinkAboutGwitchyaa Zhee Utility Company - Fort Yukon Central Wood Heating Design Final Report - Jan 2019 - Grant REF 2195405 & 7030021 Fort Yukon Wood Energy Program: Wood Boiler Deployment
Council of Athabascan Tribal Governments
Table of Contents
● Executive Summary
● Project Overview
● Objectives
● Activities Performed
● Recommendations
● Lessons Learned
● Barriers & Obstacles
Fort Yukon Wood Energy Program: Wood Boiler Deployment
Council of Athabascan Tribal Governments
Executive Summary
The Fort Yukon Gwitchyaa Zhee Corporation (GZ) worked with partners on the development of
an Integrated Biomass Energy Program for Fort Yukon. This integrated approach linked
sustainable forest management with an in- village for -profit wood harvest and delivery business
to displace diesel energy with wood energy for heat and power. The program was based on the
concept of ecological, economic and social sustainability with a goal of displacing as much
diesel and fuel oil as is technically feasible and sustainable; essentially systematically converting
a village to significant amounts of wood use.
Additionally, GZ worked with the Alaska Energy Authority (AEA) on the development of a rural
power system upgrade (RPSU) project that replaced GZ’s existing antiquated diesel power plant
and provided upgrades to the existing electrical distribution system. Due to the synergy of the
two projects, the Biomass and RPSU projects were combined to provide improved operating
efficiency, economy of scale and increased benefits to GZ, the Council of Athabascan Tribal
Governments (CATG) and the community of Fort Yukon. The combined project is referred to as
the Fort Yukon Combined heat and power (CHP) project.
The purpose of the DOE Tribal Energy Program award was to support the preconstruction tasks
and installation of wood boilers at the CATG clinic, and at the new GZ diesel power plant as part
of an overall program to create a for- profit wood energy utility in Native Village of Fort Yukon.
The CHP project provides biomass and diesel generation recovered heat via a new district
heating system to the major commercial buildings in Fort Yukon. The CATG clinic will receive
heat from a separate biomass boiler to their heating needs.
The award from the Department of Energy (DOE) Tribal Energy Program was di vided into two
phases: Design/Permitting (phase 1) and Construction (phase 2). Phase 1 (Design & Permitting)
is cost shared using State of Alaska Renewable Energy Funding (REF) funds through the Alaska
Energy Authority (AEA). Phase 2 (Construction) was funded by DOE, AEA and US
Department of Agriculture Rural Utility Service (USDA-RUS). Phase 1 of this grant, along with
a separate grant from the Denali Commission provided funding for development of the wood
delivery infrastructure necessary to support the CHP project.
Under phase 2, This DOE grant supported final design of the boiler, bidding, purchase and
transport of boilers, installation, technical support and engineering. The AEA and RUS grants
supported permitting, final design, material and equipment purchase, and construction and
installation of the new diesel power plant and district heating distribution system.
Fort Yukon Wood Energy Program: Wood Boiler Deployment
Council of Athabascan Tribal Governments
Project Overview
Background
The Council of Athabascan Tribal Governments is a consortium of ten Gwich’in and Koyukon
Athabascan tribes settled in 10 remote villages and are linked by the Yukon River system. The
region is transected by the Arctic Circle and encompasses an area of approximately 55,000
square miles (about the size of Wisconsin ). Approximately 1,700 people inhabit this sub-arctic
landscape. The region is rich in forest resources, but the Tribes face a daily struggle to meet their
communities energy needs. Village power systems are diesel generators. These diesel generators
vary in efficiency, quality, and dependability. Most major buildings are heated with fuel oil
boilers. Energy production costs are soaring since diesel must be flown or barged in to each
community. In Fort Yukon unsubsidized residential electricity costs 65 cents per kilowatt hour
compared to 8.5 cents per kilowatt in Fairbanks. CATG is currently developing a region -wide
energy plan through an Environmental Protection Agency (EPA) grant with the primary goal: to
empower Yukon Flats Tribes to work collaboratively to satisfy community energy needs while
re-investing in communities, promoting economic development, and ensuring environmental
integrity.
CATG has been working for ten years in support of the development of a model integrated
Biomass Energy Program and economic development support functions for Fort Yukon. This
integrated approach links sustainable forest management with an in-village wood energy utility
to displace diesel energy in Fort Yukon with incredibly high -energy costs. CATG has been
working to support development of a business model, feasibility studies, and specifically develop
a Forestry Management Program that includes Geographic Information System (GIS) and a
forest management plan, to support training needs for field forestry technicians and support
workshops for education on key biomass issues for Fort Yukon and the Yukon Flats Villages.
A key to success for a biomass energy and economic development project of this magnitude in a
remote village is to develop the wood supply infrastructure, which is the harvest s ystem and
wood yard, simultaneously with the infrastructure for conversion of biomass to heat. The
Gwitchyaa Zhee Corporation has a Denali Commission grant to cost share on the wood delivery
infrastructure. This project specifies that the DOE Tribal Energy Program is to cost share
specifically on the engineering, purchase and installation of biomass boilers at the CATG clinic
and the CHP facility. The goal is to displace up to 90% of the fuel oil used at the buildings
connected to the district heating network. A secondary benefit of the wood yard will be the
supply of split firewood for home heating, and in conjunction with an education program, will
spur household investment in more efficient and environmentally sound wood burning
technology.
Once a biomass delivery program has been established in Fort Yukon, it is the intent of CATG
Natural Resources Department, in collaboration with the Village Tribes and Doyon Native
Corporation, to support the development of biomass heat programs in each of the villages of the
Yukon Flats Region. The model program being developed in Fort Yukon will serve as the basis
for other biomass projects in the Interior of Alaska. Several funding sources have supported the
development of the program to date. Natural Resources Conservation Service funding helped
Alaska Village Initiatives (AVI) develop the conceptual design of an integrated biomass program
as described above. Funding from Alaska Department of Natural Resources Forestry Department
supported development of the program to date. National Resources Conservation Service
(NRCS) funding helped AVI develop the conceptual design of an integrated biomass program as
described above. Funding from Alaska Department of Natural Resources Forestry Department
supported the development of a Forest Stewardship Plan which demonstrated the potential of
local forests to supply sustainable biomass from GZ lands and a Rural Business Enterprise Grant
supported the refinement of a business model for development of the harvest.
The purpose of this funding award is to support the preconstruction tasks and the installation if
wood boilers at the CATG Clinic and CHP facility as part of an overall program to create a for -
profit wood energy utility in Fort Yukon. The award from DOE Tribal Energy Pro gram is
divided into two phases and is cost shared with Alaska Energy Authority funding. For
simplification of contracting, certain components of the project have been allocated to one
funding source; however, all tasks are considered a complete package of the project. The first
phase is pre-construction. Phase 2 is construction.
Key Program Components for an integrated process include:
● Forest Management Program;
● For-Profit Wood Harvest System;
● For-Profit Wood Yard Processing and Delivery System;
● Purchase and Installation of wood boilers for the CATG Clinic and the CHP facility;
● Technical Support and Training for each component over the life of the project.
Fort Yukon Wood Energy Program: Wood Boiler Deployment
Council of Athabascan Tribal Governments
PROJECT OBJECTIVES
The overall objective of the project is to establish a wood energy program that will reduce use of
fossil fuel for heat by up to 90% in major facilities. The concept design developed for the project
estimates a diesel heating fuel reduction of approximately 80,000-gallons for the thirteen
buildings connected to the CHP district heating system, and an additional 8,000-gallon for the
CATG Clinic. This would result in a diesel fuel savings of $440,000 annually, based on a
conservative wholesale diesel fuel cost of $5/ gallon.
The project objective with the Department of Indian Energy Thus funding was used to continue
support for the development and construction of a biomass diesel hybrid Combined Heat and
Power District Heating Plant in Fort Yukon, Alaska. The funding focus is on the development of
an 80% design for plant construction and development of a biomass harvest strategy to support
a wood-chip fire boiler system in the community.
Fort Yukon Wood Energy Program: Wood Boiler Deployment
Council of Athabascan Tribal Governments
ACTIVITIES PERFORMED
2008 SEEKING FUNDING PARTNERS
● USDA Natural Resources
● DOE Tribal Energy Program
● Division of Forestry - DNR
● Denali Commission
● Alaska Wood Energy Development Task Group
● Alaska Energy Authority
● USDA Rural Development
● State and Private Forestry
● DOE Tribal Energy/GZ/CATG/AWEA, A Collaborative Integrated Wood Energy
Program of Fort Yukon, Implementation Plan - 11.20.2008
● Feasibility for Wood Heat, A Collaborative Integrated Wood Energy Program for
Yukon Flats Villages - 11.20.2008
Feasibility for Wood Heat PowerPoint Presentation 11/20/2008, CATG Natural Resource Dept.
2009 WOOD ENERGY PROGRAM SCALES OF PENETRATION
● Village Scale - Created a Wood Energy Utility
● Commercial Buildings - Economic driver
● Households - secure relativity
● Inexpensive consistent supply
● Local management - Capacity Building
● Central Conceptual Design for Chalkyitsik Biomass, completed
● Heating Conceptual Design for Venetie Biomass, completed
2010 GARNERING COMMUNITY SUPPORT
● Community Support Meetings
● Forest Stewardship completed
● Transportation and Equipment Study Completed
● GIS based inventory completed
● 35% Boiler Modeling completed with Powerhouse
● EA in Progress
● Conceptual Design study to link powerhouse in progress
2011 DEVELOPED IMPLEMENTATION PLANS
● Environmental Assessment for a Combined Power & Biomass Heating System,
March 2011
● Business Operating Plan, Fort Yukon Combined Heat & Power Project
● Fort Yukon Woody Biomass Fuel Implementation Plan
● Implementation Plan: Harvest Area completed
● Implementation Plan: Harvest Equipment completed
● Wood Energy Deployment Meeting, Anchorage, AK - 8.24.2011
● Biomass Meeting with Venetie Tribe - 9.2-4.2011
● Biomass Project Presentation, Anchorage, AK - 9.21-24.2011
04/11/2011 Planning meeting attendees: Previous CATG Natural Resource Director James Kelly Sr.,
& Beloved Gwichyaa Zhee 1st Chief Adlai Alexander
2012 FUNDING SECURED
● Denali Commission & Alaska Energy Authority - Harvesting Equipment
$808,805
● Alaska Village Initiatives - Training & Technical Support & Harvest Plan
$258,300
● Denali Commission, Alaska Energy Authority - Comprehensive Energy Business
Plan including Power House System Upgrade (1st Draft completed) $60,000
● Alaska Energy Authority - Final Designs funds $210,000
● Department of Indian Energy - Phase 1, 80% Design $210,000
● Department of indian Energy - Construction funds $990,000
● Alaska Energy Authority - Construction funds $2,300,000
● Gwichyaa Zhee Corporation - Company Start-Up Funds $300,000
● Denali Commission & Alaska Energy Authority - Diesel Power House Design &
CHP BOP $280,000
● Alaska Energy Authority - Diesel Powerhouse Construction $3,500,000
● Gwichyaa Zhee Corporation - Diesel Powerhouse Construction $400,000
● Total Funding Secured: $9,317,105
● Wood Energy Workshop, 10.14-19.2012
2013 ASSESSMENTS & PERMITS COMPLETED
● CATG/GZ Corporation Biomass Harvest Agreement 2.28.2013
● NEPA Environmental Assessment (FONSI) completed 5.6.2013
● Revised heat utility model submitted and passed 7.26.2013
● Eagle Nest Survey completed 8.17.2013
● State of Alaska issued Alaska Forest Practices Act permitting 9.13.2013
● CATG Natural Resources Director Training: Forestry Technician Training:
Basic Forest Skills 9.23-27.2013
● State of Alaska issued permit to cross Yllota Slough 10.9.2013
2014 NETWORKING
● Presentation to Council of Athabascan Tribal Governments and Gwichyaa Zhee
● Equipment Assessment Needs, Task strategy for each piece of equipment;
Procurement List developed -
● Department of Tribal Energy Review: Golden, CA 3.14.2014
● Alaska Wood Energy Conference: Fairbanks, AK 4.15.2014
● Chipper Training & Demonstration: Best Operational Safety Practices;
Equipment Assessment; Biomass Moisture Measurement Requirement; Wood
Chip Moisture Content; Hooking up/Loading & Unloading Chip Trailer & Bins
7.15-18.2014
● Harvest Equipment Operator & Safety Training (Kubota) - 11.4-6.2014
● Operator Training, Biomass Harvesting Mechanisms & Processing - 11.6.2014
● Training of Rural Forest Technicians Begins 12/1/2014
2015 DESIGNS & SETTLEMENT OF PAD
● Invitation to Bid for CHP Building package - January 2015
● 35% Design & Construction Estimate completed 3.25.2015
● Established force account payroll & reporting procedures completed 6.4.2015
● Site Development final design completed 8.25.2015
● Pad left to settle over winter months Fall 2015 & the Non -structural pad will be
completed during the Spring of 2016
● Storm Water Pollution Prevention Program (SWPPP) stabilization measures
were implemented to shut down construction until Spring 2016
● Training of Rural Forest Technicians Ends 12.1.2015
2016 CONSTRUCTION
● State of Alaska
● Final stamped Design Drawings for CHP Building package completed 1.20.2016
● Invitation to Bid for Biomass Boilers and Arctic Piping - February 2016
● 32% of Site Development Invoiced - 2.24.2016
● Completed CHP Building Pad - 6.6.2016
● CHP Building Mobilization and Completion of Concrete Footings and Slabs -
June 6, 2016
● Final Stamped District Heat System Design drawing complete 6.8.2016
● CHP Building Steel Erection - 7.22.2016
● Final Stamped Biomass M&E Design drawings completed 7.28.2016
● Long Lead Items Procurement for CHP and district heat completed 7.31.2016
● CHP Building Exterior Complete - 8.5.2016
● Procurement of PEX Arctic Piping Materials, Steel Arctic Pipining, & other
miscellaneous procurement
● District Heat Final Design Drawings Issued - 7.29.2016
● Heat Sales Agreement signed by the State of Alaska, Yukon Flats School
District & KZPA Radio
● District Heat End-User Building mechanical work complete
● Installation of District Heat Arctic Piping began - 8.1.2016
● Construction CHP Building completed 9.26.2016
● Trenching, install district heat equipment in end-user buildings completed
10.31.2016
● Department of Tribal Energy Program Review: Denver, CO 11.14-17.2016
Previous CATG Natural Resources Director James Kelly Sr & GZ Corporation CEO Frannie Hughes
presenting at the 2016 Tribal Energy Conference, Denver, CO.
2017 CONSTRUCTION/TESTS/OPEN HOUSE
● Commission district heat system completed 1.7.2017
● Additional district heating glycol procurement completed 8.2.2017
● Biomass boiler arrived on site 10.3.2017
● Biomass push floor trailer arrived on site 10.6.2017
● Department of Tribal Energy Program Review: Denver, CO 11/13-16.2017
● GSE progress inspection & troubleshoot problematic Series 60 idle issues
11.16-17.2017
● CHP Ribbon Cutting to the David Lee Thomas Powerhouse 11.17.2017
● Gutter prefabrication, CHP Electrician completed electrical work with materials
on site 12.4.2017
2018 REPAIRS/TESTING/FINAL PRESENTATION & FINAL REPORT
● Current River Electric, Biomass equipment repair 1.16-29.2018
● Install Biomass VFD Display, Boiler testing and Boiler SCADA communications
verified 6.8-10.2018
● Final Presentation by Gwichyaa Zhee, CEO Frannie Hughes 12.14.2018
● Submitted Final Progress Report to the Department of Tribal Energy 12.29.2018
2019 TECHNICAL REPORT SUBMITTED
● Submitted Final Technical Report to Department of Tribal Energy, by Bruce
Thomas, CATG Natural Resources Director 3.30.2019
Old Site
New Site
Fort Yukon Wood Energy Program: Wood Boiler Deployment
RECOMMENDATIONS
1. MEMBER TRIBES OF CATG DID NOT BENEFIT
● The Council of Athabascan Tribal Governments is a consortium of ten tribes one
of which is the Gwichyaa Zhee Gwich’in Tribal Government (GZGTG). The third
constitutional intent of CATG is to aid and support economic development for
member tribes. We are pleased and appreciate the opportunity that the
community of Fort Yukon benefitted from the Fort Yukon Wood Energy Pro gram:
Wood Boiler Deployment initiative. However, we make plain our
disappointment that the GZGTG was not tied into the waste heat loop.
● Although CATG served as a pass-through entity, we were ultimately responsible
for the grant and thus responsible for the Quarterly, Annual, Final and Technical
reports. Further, CATG also had to: 1) Carry adequate insurance to indemnify
the GZC from liability due to an accident or negligence; and, 2) Be responsible for
the filing and maintaining records of permit applications.
● The Gwichyaa Zhee Corporation is exploring options of tying in other entities to
the waste heat loop. It is our recommendation that the GZGTG be inclusive of
this endeavor.
2. CONTRACTS THAT ARE ENFORCEABLE
● The grant is over; but, not the problems. Hindsight tells us that in order to avoid
disputes and misinformation, pre-signed legal and binding contracts by all
stakeholders should have been executed prior to construction. One contract
was not signed. This is by the Co-Partner at the end of the loop. Now, we
cannot simply shut this Co-Partner off because there are no shut off valves into
any of the Co-Partner buildings. This Co-Partner did not sign a contract but was
part of the project.
● It is the recommendation of this grantee that prior to construction, in order to
facilitate and foster continuity all co-partners must perform the following: 1)
Contracts are read and understood before signatory authority issued; 2)
Contracts are confirmed in writing and by receipt; 3) Co-partners know their
legal obligations; 4) Leads develop good and continuous communications and
relationships; 5) and, Leads be organized in training of new incoming
administration in respective Co-Partner entities.
● This grantee believes that all Co-Partners must have a continuing obligation to
the project and the subsequent maintenance of the project. This must be
cemented, prior to project implementation, by a legal and binding contract.
2. ENSURE DEED SITE CONTROL
● One recipient of the loop rents from another entity that is also included in the
loop. So, Recipient A looks for guidance from Recipient B since Recipient A rents
from Recipient B. When it came time to provide data, Recipient A was reluctant
to provide fuel consumption data since the installation of the loop because
Recipient B made their position known and voiced their opposition to proving
the requested data. Recipient A is fearful of retaliation from Recipient B and
have no other venue to conduct business should Recipient B evict them. It is the
recommendation of this grantee that all Co-Partners have deeds to their own
land and buildings before they are included in the grants. This is to avoid strife,
contentions, and gang-ups down the road and all recipients’ autonomy would
not be dictated by the views and opinions of another.
● The very first hurdle was to work with the local tribal entity to gain access to a
parcel of land to build the new generator. We were overly long in this fray to
gain site control where the new generator now sits. It is the recommendation of
this grantee that deed issues be resolved prior to grant implementation.
3. IDENTIFY LOCATOR PROBLEMS
· It is the recommendation of this grantee that prior to implementation of the
project, that Locator lines be ascertained such as phone, water, and gas lines.
This entails cooperation from the phone company and the city in which the
project is being implemented. A private company had to be brought in to locate
the water lines at an additional cost of $6,000. A Co-Partner demonstrated
resistance and zero cooperation with providing location of the lines.
Cooperation of Co-Partners must be included in the contract no matter the turn
over in administration.
4. TURN OVER IN ADMINISTRATION OF CO-PARTNERS
● There has been mass turnover since the inception of the Department of Indian
Energy Biomass grant with CATG. 85% of the original co-partner administrators
including those within CATG are no longer in office. However, Gwichyaa Zhee,
the main stakeholder, remains cognizant of the original intent of the grant
throughout all of the stages: concept, proposal, award, implementation to
closeout. CATG and GZ recognizes that there was a need for continued
education involving the four beneficiaries of the loop to remain abreast of
changes, original contract obligations, and the progress of this endeavor.
● It is the recommendation of CATG that an ongoing list of Co-Partners be
maintained for continuity purposes, and as the need arises, t he successor(s) be
apprised of the grant and grant intentions in a short fact sheet. A current
problem is tensions are high because of this turnover. It is the intent of CATG to
hold a Co-Partners luncheon with all the stakeholders for educational purposes:
● To apprise all of the original intent, goals and objectives, and benefits of the
grant. And now that the grant is over – how to maintain the system and the
responsibilities
● To make plain our responsibilities as the Pass-Through grantee.
● To enlighten Co-Partners of their responsibilities and explain the contracts they
signed
○ There is an ongoing list of Administrators from each entity/council
○ As each position receives a new person, this needs to be appraised in the
Contract/grant.
5. MORE EDUCATION OF BENEFITS IN COMMUNITY
● There were breakdown in communications, change in administration, technical
problems, rumors of differing views and underlying facts. With present
problems with new Administration within the Co-Partners.
● How do we fix this? All co-partners need to be brought back to the table to
discuss how the Biomass Projects benefits the whole community. The Yukon
Flats School District benefits because 48% of their previous funding was
exhausted by fuel consumption. Now, funds are freed up for st udent instruction.
The State of Alaska, the most efficiently maintained, benefits by freeing up
funds for law enforcement. The KZPA Radio station benefits by being unfettered
by the high cost of fuel and continue to be the “voice” of the region. The Ci ty of
Fort Yukon benefits because, they too, are disenthralled by huge fuel
consumption and can now concentrate on quality water service and expanding
service delivery to the new subdivisions.
● It is our recommendation that future grantees would have more meetings with
the Co-Partners and community education in support of long term sustainability
of the Biomass at each progressive step during project development.
6. INFRASTRUCTURES IN PLACE
● There were too many re-designs of the building and loop installation resultant in
unexpected cost and rebudgeting . It is the recommendation of this grantee that
there are pre-planning steps that other grantees follow prior to inception. The
five biggest factors working against us were: lack business and forest ry plans,
time, isolation, cold weather and not planning adequately for these factors.
1. We did not have a Business or Forestry Plans in place prior to inception. A
Business Plan would have given us a roadmap to follow that shines a light on the
cohesive vision and endeavor. Also, a Forestry Plan was needed at the beginning
to determine: where wood was to be harvested, when, by whom and where to
store it in the interim before it is actually furnace ready.
2. From start to finish was ten years. Because of this project estimates had
changed, some vendors that we were dependent on were no longer in business
which caused us to desperately seek out new vendors when the time was right.
Inflation had changed the cost not only in merchandise pricing but t he shipping
thereof, and there were cold weather delays.
3. The location in which the project was done is extremely isolated. Weather and
or other factors can hinder transportation of the materials, gear and machinery.
If weather prevented the last barge from coming, that would throw off the
execution of the next phase that was dependent on said materials. Fort Yukon is
not on the road system and project’s overrun and budget rewrites was often. It
is our recommendation for a more accurate analysis of cost expenditures and
contingency plans should barge schedules change.
4. Machinery is hard to operate or breaks down during extreme cold. Fort Yukon is
in a valley between two mountain ranges. The law of the cold seeks out the
lowest elevations. Future grantees should factor in extreme weather and
determine whether or not that this could hinder their project.
5. The project demanded static expenditure projections. Time and again, the
timeline changed because of the isolation and weather. This caused delays,
substitutions, rewrites, and replanning. A grantee needs to take into
consideration and make contingency plans caused by isolation and weather.
● The Chipper Bay space has insufficient space to dry the wood chips. A Chipper
Bay should have been in another building not only for drying purposes but also
for safety reason. We needed more wall protection in the Chipper Bay than the
design called for. But, this entailed a re-negotiation. Another reason why a
separate building is needed is because the type of spruce that grows in this area
possess more moisture than spruce to the south of the White Mountains.
Consequently, this requires a longer drying time which demands more space for
the “various levels of dryness” piles.
● Plexiglas needs installing over the converter. When the operator needs to see
the conveyor, he has to lift up the converter window. When the converter
window is lifted up, the conveyor stops. It would behoove the next grantee to
install Plexiglas over the converter.
7. ENERGY AUDITS NEEDS TO BE DONE PRIOR TO INSTALLATION
● The purpose of an energy audit is to analyze energy flows within a building.
Energy loss could be due to insufficient insulation, windows, doors, age and type
of furnace. Only by happenstance did we learn of the energy ineffectiveness of
some of the buildings. This led to energy loss and re -analyzation by the engineer
as to why some buildings were more efficient than others. This was an added
cost. Some of the Co-Partners had to be informed on heat loss caused by
opened windows, poorly monitored thermostat control settings, and poor
insulations. This was after the loop was installed and the loop turned on.
● These energy audits needs to be included in each contract. And, that the Co -
Partners agree to stipulations and maintenance prerequisites regarding heat
conservation by regulating their respective thermometers and refrain from
opening windows and doors in the winter months. The waste heat loop is a
continuous loop. Once it circulates one building, it continues on to the next
building. If heat is lost in one building, the next building will not receive the
same amount of service as the previous building. In short, this actually robs the
next recipient in the loop of the same quality of service.
● It is this grantees recommendation that each Co-Partner utilize an energy use kit
or an energy audit prior to installation in each building that will be receiving
waste heat. Only after an energy audit is conducted that Co -Partners could be
included in the grant.
8. INSTALLING SHUT OFF VALVES
● Waste heat loop should have individual shut off valves. Upon being hooked up
to the loop, it was found that some entities were uncooperative in providing
fuel-use data for our reporting and refuses to pay a maintenance fee. We are
unable to shut off their services from the heat loop, as the design format was a
universal-circulatory loop.
● It is our recommendation that all future grantees should have shut off valves for
this purpose.
● Ultimately, everyone benefits from this project - the whole community. Should
the economy collapse, then power can continue to be provided via the wood
boiler system. However, there is such strong resistance from one of the Co -
Partners that is erroneously under the impre ssion that since the waste heat loop
was installed by a grant therefore it is free. Yes, the loop was installed by a
grant, however the maintenance is not free and comes at a cost. Again, our
recommendation is to have contracts in place prior to construction.
9. BLUEPRINTS NEED TO BE IN 3-DIMENSIONAL FORMAT
● There are many facets and steps in any construction project. Some still utilize
the traditional 2-dimensional method as did we. This had led to some costly
problems in which walls had to be torn down and rebuilt using sound-proofing
materials. A 3-dimensional blueprint would have served the project better as
grantee could have been cognizant of the type of construction for a sound -
proofing wall and ceiling for the office as a sound barrier against the generators.
● Also, in the new power plant there is no wall space much less space to lay out
the 2-dimensional blueprints. There were times when all the construction staff,
at safety meetings, needed to see the blueprints and to be cautioned where
hazardous construction was taking place in order to avoid thee area(s).
However, there was no space to crowd around a 2-dimensional blueprint. It
would have served the project well to have a pull-down projector screen to
project the 3-dimensional blueprint for fast and efficient viewing.
● This project entailed using three different electrical vendors. Grantee was not
informed where the installations were taking place and there were times after
the vendor left, that staff had to make an educated guess where the outlets
were. It is the recommendations of this grantee that staff meet with all in -
coming vendors to discuss the phase and purposes of their contributions using
the 3-dimensional blueprints. Should we have had these blueprints in 3-
dimensional format, then the three vendors’ work could have been dovetailed
seamlessly.
10. NEED MANUALS PRIOR TO FINAL REPORT
● Because we are only the 2nd entity to have established a wood boiler in the
Interior, we have to build our own user manual, and independentl y navigate any
problems that arise during operation of the wood boiler.
11. MORE PERSONNEL
● This is a big operation that requires four cords of wood per day for 275 days a
year. There were two things that were not expanded on: Sustainability after
construction and space.
● In order to sustain a project of this magnitude, our two Generator Operators
have enough to do without this added duty. At least 3 people for a crew to
constantly operate the wood boiler: consisting of a Wood Boiler Manager, Yard
Worker, and a Dryer/Feeder. The Wood Boiler Manager would have supervisory
authority over the Yard Worker and the Dryer/Feeder.
● Project does not have the floor space for curing the chips via air drying and/or
heat drying; thus have opted for the Self-Drying method outside of the building.
This requires managing many piles and each with different levels of dryness.
● The Boiler deem that chips that are ___% cured can be used. We live in Alaska
with a shorter drying season. Again, this requires chip pile maintenance.
● It is our recommendation that grantee should plan for drying space any using
one of the three methods determined by their climate. Further, it is our
recommendation that grantee plan for long-term sustainability and the
employment of more personnel to manage the endeavor.
12. SECURITY NEEDED
● The compound needs fencing with surveillance. Currently, this is an unprotected
area. Reality tells us there is an increase in theft, vandalism, arson, and crime in
our area. The recovery of stolen items is miniscule. This is a multi-million dollar
facility and should be protected from theft, vandalism, arson, and other crime.
● This project demands four cords of wood per day for approximately 275 days of
the year. That is a lot of wood. Given that the wood will be coming in daily, it
needs to be secured in a fenced in area. The fencing would also deter crime as it
sends a message that theft, vandalism, arson, and other crimes committed
against us will not be tolerated.
13. KNOW YOUR VENDORS
● Please know your vendors. It has been our experience that there are many
vendors that are out there that do not share your same values. Some vendors
just want to get the job done and get out as quickly as possible. Others would
“milk” the job. GZ has the best Manager and she was able to discern the latter
immediately. For the former, Quality Control was an issue of those vendors who
are not local and have no vested interest in the project other than monetary
gain.
● A grantee must check the reliability and reputation of their vendors. We
recommend that vendors be checked with the Better Business Bureau.
Fort Yukon Wood Energy Program: Wood Boiler Deployment
Council of Athabascan Tribal Governments
LESSONS LEARNED
1. MORE PLANNING WAS NEEDED
It would have behooved us to have had more strategic planning which is a process of
organization that streamlines our vision, direction, goals, objectives and objectives,
priorities and decisions aligning them to our resources to accomplish action items. The
Strategy Plan it would have demanded us to write both a Business Plan and Forestry
Plan to ensure a smoother operation. These plans were written eventually.
a. A Business Plan is a very important planning tool for any new business venture,
who are serious about starting a business and details our purpose; essential to building
human resources and operational requirements and needs. It would contain Action
Plans for each objective detailing how it was to be accomplished by answering these
universal questions prevalent in Action Plans: what was the plan, why and for what
purpose, who & how many manpower hours are required, where was it to take place,
when was it to take place, and how was it to be accomplished.
b. In the same token, A Forestry Plan would have helped immensely containing the
same universal questions as above, but also inclusive of the permits needed,
contingency plans should a natural disaster strike, stewardship of the land, where to cut,
etc. In our case, a natural disaster did happen. The Yukon River Flood of 2013 destroyed
our harvesting site. Again, the Porcupine River Flood of 2015 negatively impacted us.
The site that GZ was planning to use for pad construction were not accessible which
resulted in a delay. The pad was completed in Fall of 2015 and left to settle during the
winter months.
The Lesson Learned is to have multiple sites of harvesting. We do now, but not at the
time of the flood.
Photo above of Yukon River Flood, Fairbanks Daily News Miner 5.22.2013
2. CONTRACTS THAT ARE ENFORCEABLE
In the Recommendations portion of this report we have detailed this issue. In summary,
legal and binding contracts are necessary to avoid disputes and resistance during any
phase of the grant operations. For years, one Co-Partner vacillated between
cooperating and opposition of which a contract was never legally ratified. This Co -
Partner is at the end of the loop which makes turning off the loop an impossibility
without negatively impacting the other Co-Partners. We will seek funding to install
individual shut off valves.
3. BETTER COMMUNICATIONS WITH CO-PARTNERS
Many people are visual people, they like to see where they currently stand, percentage
of project completed and what was accomplished. They also like to see what still needs
to be done and how far they are from project completion. Building a status timeline is
possible using Google suites that details each phase of the project. It is our Lesson
Learned that more and consistent communications with Co-Partners is paramount.
Also, to have communicated project status on a consistent basis using this type of
timeline.
4. NEEDED MORE CONTINGENCY PLANS
The project duration was ten years. Many of those that were initially trained have
moved on to other communities or professions. A whole new generation of workers
need to be trained. First in Safety, Equipment, & how to harvest the timber resources.
There were many factors that contributed to delays in the project that resulted in
project extension: of which extreme climate and isolation were the biggest factors.
One vendor dropped and broke a generator which caused a seven month delay because
a replacement had to be ordered from Canada. A Lesson Learned is to plan, plan, plan.
Fort Yukon Wood Energy Program: Wood Boiler Deployment
BARRIERS AND OBSTACLES
CLIMATE FACTORS/EXTREME COLD
● One has to be a tough and hardy breed to live and operate in the Arctic. The Yukon Flats
of the Interior of Alaska is between two mountain ranges, where the cold settles in and
around the Yukon River valley. Temperatures can reach an ambient temperature of -60
degrees below Fahrenheit or colder when there is a wind chill.
● Winter operations is hard on vehicles, equipment and machinery. The cold plac es
extreme stress on these necessary items causing them to become brittle and thus easy
to break. Equipment must be thawed and a marine blanket placed over equipment to
retain the heat transmitted by a space heater. Even still, care must be taken in
operations as hydraulics have a propensity to leak from plastic hoses. The harsh climate
does damage to tangible machinery. We had to purchase a crimping machine to make
“Artic hoses” that would withstand the cold.
● Since this is an isolated place, there are no auto-repair or equipment-repair businesses.
Mechanics will need to be flown in to repair machinery at an added cost to the program
should machinery breakdown.
● Reiterated from Recommendations. As stated above, the spruce and cottonwood that
grows in the Yukon Flats has a heavier moisture content in the wood than spruce that
grows south of the White Mountains. Wood is hygroscopic as it gains or loses moisture
as the RH of the air surrounding it changes. As the humidity increases the moisture
content increases causing the wood to expand. Too, we have such short growing
seasons that moisture becomes trapped in the raw wood which requires a longer drying
time.
● Too, many times the wind would contribute to a wind chill of -70 below degrees
Fahrenheit. It is time-consuming to get any job done due to the cold climate.
● It is our recommendation that the cold factor be written or recognized in the grant of
grantees. Harvesting of wood should be done in the spring and summer seasons. Most
of the wood harvested is during the fall and winter seasons because it is easier to
transport over the snow. But, this would require a longer drying period. It would be more
beneficial to harvest wood in spring and summer seasons in order for a shorter drying
time.
●
ISOLATION
● This CHP Biomass Project is the first off grid road system CHP facility in the world. Fort
Yukon, in the Interior of Alaska, is geographically isolated since our area is accessible
only by air during the winter and by barge or air in the summer and parts of the fall. It is
our recommendation that this factor is taken into context during the planning and
development of a proposal, during budget development, and the execution of the grant
thereof.
● This isolation will cause an increase in freight costs. Too, a ll your transportation options
must be explored in case one mode becomes unavailable.
● Product availability is a factor. One cannot just run down to the local hardware
company as there is none here. Some companies would ship and charge for the
expedition fee. However, said freight would come in as space available or FIFO (First In
First Out) policy. This must be taken into consideration.
● There is another hurdle that we had to overcome and that concerned the box -warranty
of equipment that had to be modified for the harsh climate. For example, if the
equipment had to be modified this resulted in modifying the manuals as well.
TRYING TO DO TOO MUCH WITH TOO LITTLE
● This was a great project and the benefits are considerable. However, a Cost Study
Analysis should be a methodology used for grant amounts. A small example of the high
cost of merchandise in rural Alaska is: In Fairbanks, Alaska, an urban hub of Interior
Alaska, a loaf of bread is $1.99 compared to Fort Yukon where that same loaf sells at
$8.46 which is 425% higher than urban Alaska. In this context, the freight and expeditor
cost should always be included at a higher amount the further the grantee is away from
the source.
● The Washington D.C. climate is waning for Native American grants. Admini strators and
Tribal employees are forced to wear many hats with resources stretched so thin: trying
to do too much with too little! This has always been the case in Indian Country.